GLIDEG9R T5, T5HO and T8 Direct/ Indirect luminaire Perforated Project Name Date Catalog Number Type CONSTRUCTION One piece die-formed steel housing in a 8-3/4” by 2-1/2” profile. Standard 4’-0”, 8’-0” and 12’-0” fixtures can be joined to create continuous runs. REFLECTOR Standard high reflectance die-formed white painted aluminum. Optional specular reflector. ENDCAPS Precision die-cast sculpted endcaps are fastened with concealed hardware. PERFORATED PANELS Panels measure 2.5” by 43” every 4 feet. Diameter is .094 on 60 degree stagger with .1875” hole centers. Opal diffuser included. ELECTRICAL T5, T5HO: Program start 120/277 volt integral electronic ballast with less than 10% THD. T8: Instant start 120/277 volt electronic ballast with less than 10% THD. Through wiring with quick connects standard. Standard single circuit. Each ballast provided with disconnects to meet luminaire disconnect code requirement. MOUNTING Adjustable aircraft cable mounts on 4’-0”, 8’-0” and 12’-0” centers. Aircraft Cable supplied with 5” power and 2” non-power canopies. Refer to installation instructions for appropriate ceiling detail. Canopies and power cords are painted white unless otherwise specified. FINISH Standard powder-coat white painted finish. Consult factory for custom color and finish options. LABELS UL and cUL Listed and approved for dry/damp location. STANDARD LIGHT DISTRIBUTION Direct 5%; Indirect 95% T5 Cross Section T8 Cross Section 2-1/2" 2-1/2" 8-3/4" 8-3/4" Lamp Options YEAR WARRANTY 1T5, 1T8 LFL Convertible L U M I N A I R E S P E C I F I C AT I O N LED 2T5, 2T8 LED Lamp Options LFL _T___- ___’- ______- ___- HOUSING LAMPS LENGTH MOUNTING VOLTAGE 1T8 Sample Catalog #: G9R-1T5HO-32’-AC48G1-120-1C-W __-2T8 CIRCUITING Convertible Adjustable Aircraft Cable1,2 AC48G1- 1” T-Bar AC48G9- 9/16” T-Bar AC48GS- Slotted T-Bar AC48JB- Junction Box AC48ST- Structure AC548G_- 5” Non-Power Canopy3 5” Non-Power Canopy3 AC548JBLED Convertible 5” Square Canopy3 SQ48G_LFL SQ48JB- 5” Square Canopy3 __- 120277347UNV- 120 V 277 V 347 V4 UNV4 LED LED 4T8 ___ YEAR 3T8 WARRANTY YEAR WARRANTY LFL 1T5- (1) 28W T5 2T5- (2) 28W T5 3T5- (3) 28W T5 4T5- (4) 28W T5 YEAR 1T5HO- (1) 54W T5HO WARRANTY 2T5HO- (2) 54W T5HO 3T5HO- (3) 54W T5HO LFL 4T5HO- (4) 54W T5HO Convertible LED 1T8- (1) 32W T8 2T8- (2) 32W T8 3T8- (3) 32W T8 Individual Units 4- 4’ 4T8- (4) 32W T8 8- 8’ 12- 12’ Continuous Runs xx’- Specify nominal overall row length in 4’ increments 4T5, 4T8 Convertible G9R- G9R-Glide Direct/Indirect indoor luminaire with perforated panel 3T5, 3T8 FINISH LFL Convertible Convertible LFL LED W- Matte White CC- Custom Color OPTIONS LED Convertible LFL (120/277) 1C- Single Circuit 2C- Dual Circuit5,6 1D- Single Circuit Dimming5 2D- Dual Circuit Dimming5,6 1E- Single Circuit with Emergency Circuit5 2E- Dual Circuit with Emergency Circuit5,6 1B- Single Circuit with Battery Pack5 2B- Dual Circuit with Battery Pack5,6 DSM- Daylight Sensor Master (sensor included)7 DSS- Daylight Sensor Satellite (sensor not included)7 MS- Motion Sensor DG- Dust Guard (Covers top of luminaire) SR- Specular Reflector 8 QS- Quick Ship Low Ceiling Reflector LCR(1, 2 lamp T5, T5HO) CL- 90 Degree Corner CX- X Connector CT- T Connector 1Standard 48” Adjustable Cable. Consult factory for additional lengths. 2Consult factory for tegular edged tiles. 3Replaces standard 2” non-power canopy. Square canopy replaces standard round. Must specify grid ceiling type on AC548G_ and SQ48G_. Select from G1 (1” grid), G9 (9/16” grid), or GS (slotted); for example AC548G1. 4347 volt and UNV not available with battery packs. 5Some Glide configurations will not accommodate all electrical options. Consult factory. 62 lamps switched side-by-side, 3 and 4 lamps switched inboard/outboard. 7See back page for ordering information. Requires 0-10 volt dimming. 8Includes Universal voltage, standard white, single (1C) and dual circuit (2C). ® Pinnacle Architectural Lighting 12655 East 42nd Avenue, Suite 50 Denver, CO 80239 Phone 303.322.5570 Fax 303.322.5568 www.pinnacle-ltg.com © 2012 Pinnacle Architectural Lighting® April 2012 Specifications and dimensions subject to change without notice. Specification sheets that appear on pinnacle-ltg.com are the most recent version and supersede all other previously printed or electronic versions. PHOTOMETRICS 3.0" 1 1502 48.0" 4' 1126 1.60" 375 96.0"1 12.0" 1Endcaps 2202 3296 2472 3394 to the overall length of the row. 1101 1648 2263 551 824 1131 1652 Must add 3” for each endcap or 6” 751 10.40" G L I D E G 91.60" R / T 5 , T 5 H O ,1.60" T8 12.0" 4525 8' CL = 90 Degree Corner Test # 202742 Part #: G9R-1T5HO-4-SR Total Luminaire Efficiency: 87.2% Direct: 5%; Indirect: 95% Test # 202748 Part #: G9R-2T5HO-4-SR Total Luminaire Efficiency: 85% Direct: 5%; Indirect: 95% INDIVIDUAL LUMINAIRES Test # 202753 Part #: G9R-3T5HO-4-SR Total Luminaire Efficiency: 83.3% Direct: 5%; Indirect: 95% Test # 202757 Part #: G9R-4T5HO-4-SR Total Luminaire Efficiency: 81.4% Direct: 5%; Indirect: 95% 1.60" 1Endcaps Must add 3” for each endcap or 6” to the overall length of the row. 4' CX = X Connector CORNERS 3.0" 48.0"1 CT = T Connector 10.40" 1.60" 1.60" 12.0" 12.0" 96.0"1 8' 144.0"1 12' CL = 90 Degree Corner CT = T Connector CX = X Connector LOW CEILING REFLECTOR APPLICATION: Glide’s low ceiling reflector eliminates hot spots while increasing uniformity across the 1 ceiling. Utilize when48.0" fixtures must be installed as close as 10” from the ceiling. Available on 1 and 2 lamp 4' T5, T5HO fixtures only. 3.0" 1Endcaps 1.60" Must add 3” for each endcap or 6” to the overall length of the row. 10.40" 1.60" 12.0" 1.60" 12.0" 1 painted aluminum. Low Ceiling Reflector 96.0" CONSTRUCTION: Highly reflective white securely snaps onto top of the lamp. 8' ORDERING INFORMATION: Specify “LCR” in the options section of the part number. (Sample Catalog #: G9R-1T5-32’AC48G1-120-1C-W-LCR) DAYLIGHT SENSOR Glide Side Baffle shown APPLICATION: Daylight sensors are an ideal solution for saving energy , creating smart environments and aiding sustainability. Pinnacle LightIndicates sensor location Example 1 ing’s daylight sensor is a turn key solution 4DSM 4’ for lighting control. The sensor is easily wired 4’ individual fixture with a Daylight Sensor. to Specify: the 0-10G9B-2T5-4’-AC48G1-120-1C-W-4DSM volt dimming ballast installed in the Example 2 fixture. location DAYLIGHT SENSOR: Daylight sensor Indicates dims lightssensor based on electric light and 8DSS 8’ 4’fixture wired presence of daylight. control up to 20 dimming ballasts. Sensor 8’ individual to a DSMSensor fixture. can Specify: G9B-2T5-8’-AC48G1-120-1C-W-8DSS Example 3 is8’factory calibrated to 45 footcandles (fc), adjustable by 1/3 to 3 times the default setting by rotating the aperture. 8DSS 8DSM 16’ SENSOR 8’ fixture STANDARD with a Daylight Sensor andPLACEMENT: 8’ fixture wired to The DSMsensor fixture location in Glide fixtures 12’ for easy placement of the sensor in relation to the space being daySpecify: allows G9B-2T5-16’-AC48G1-120-1C-W-8DSM+8DSS lighted. Housings can be rotated for more flexibility. CL = 90 Degree Corner CT = T Connector CX = X Connector ORDERING INFORMATION: Specify row layout in the Options section of the part number when ordering Remote Daylight Sensor. Remote Daylight Sensor Master (DSM) includes the fixture with remote sensor and dimming ballast. Controls DSS units. Remote Daylight Sensor Satellite (DSS) includes the fixture with a sensor compatible dimming ballast only. Must be used in conjunction with a DSM unit. See example 4 and 5 for information on ordering rows with both standard circuiting and daylight sensor. Indicates sensor location Example 1 4DSM 4’ 4’ individual fixture with a Daylight Sensor. Specify: G9R-2T5-4’-AC48G1-120-1C-W-4DSM Example 2 8DSS 8’ 8’ individual fixture wired to a DSM fixture. Specify: G9R-2T5-8’-AC48G1-120-1C-W-8DSS Example 3 8DSS 8DSM 16’ 8’ fixture with a Daylight Sensor and 8’ fixture wired to DSM fixture Specify: G9R-2T5-16’-AC48G1-120-1C-W-8DSM+8DSS Example 4 82C 8DSM 16’ Indicates sensor location 4’ 8’ fixture with a Daylight Sensor + 8’ fixture wired as standard dual circuit (not wired to the sensor) Specify: G9B-2T5-16’-AC48G1-120-2C-W-8DSM+82C Example 4 82C 8DSM 16’ 8’ fixture with a Daylight Sensor + 8’ fixture wired as standard dual circuit (not wired to the sensor) Specify: G9R-2T5-16’-AC48G1-120-2C-W-8DSM+82C Example 5 81C 12DSM 20’ 12’ 12’ fixture with a Daylight Sensor + 8’ fixture wired as standard single circuit (not wired to the sensor) Specify: G9B-2T5-20’-AC48G1-120-1C-W-12DSM+81C Example 5 81C 12DSM 20’ 12’ fixture with a Daylight Sensor + 8’ fixture wired as standard single circuit (not wired to the sensor) Specify: G9R-2T5-20’-AC48G1-120-1C-W-12DSM+81C 8’ Indicates sensor location 4’ Pinnacle Architectural Lighting 12655 East 42nd Avenue, Suite 50 Denver, CO 80239 Phone 303.322.5570 Fax 303.322.5568 www.pinnacle-ltg.com Example 1 Indicates sensor location 8’ © 2012 Pinnacle Architectural Lighting® April 2012 4DSM 4’ Specifications and dimensions subject to change without notice. Specification sheets that appear on pinnacle-ltg.com are the most recent version and supersede all other previously printed or electronic versions. 4’ individual fixture with a Daylight Sensor. Specify: G9W-2T5-4’-AC48G1-120-1C-W-4DSM ® Example 2 12’