OSC-16 for imc CRONOS-PL/-SL/compact Technical Data Sheet 04.10.2013 OSC-16 for imc CRONOS-PL/-SL/compact 16-channel isolated differential amplifier Data Sheet version 3.4 The OSC-16 is a scanner module with optical relays, equipped with 16 isolated and differential input channels. It comes with enhanced isolation strength of up to 60 V, and its 16 channels allow measurement of voltage, current, thermocouples and Pt100. The OSC-16 is available as a plug-in module for imc CRONOS-PL/compact and as a configuration module for CRONOS-SL. Highlights Ideal for isolated measurement of passive sensors optimal suppression of 50 Hz interference support of TEDS (imc Plug & Measure, Transducer Electronic Data Sheets (IEEE 1451.4) imc CRONOScompact - modular measurement system imc CRONOScompact is a modular and reconfigurable hardware a "rack"-based series of devices available in different housing sizes and device frames. imc CRONOScompact (CRC) plug-in-modules can be plugged in imc CRONOScompact System (CRC-400 / CRC-2000G). This assembly of such a system can be adapted fast and easily. imc CRONOScompact plug-in-modules Once the modules are built-in a portable or rack-based housing, the modules will electrically connected to the imc CRONOScompact (CRC) system and they will also be supplied by the system. The data storage will also be managed by CRC. The front panel of the rack-based modules ("-R") is different to the front panel of the portable housing. The properties of both types is the same. imc CRONOScompact portable housing Overview of available variants Order code Article no. CRC/OSC-16 CRC/OSC-16-ET CRC/OSC-16-T 1170054 1171029 1170103 CRC/OSC-16-T-ET CRC/OSC-16-R CRC/OSC-16-R-ET CRC/OSC-16-T-R 11710xx 1170118 1171077 1170184 CRC/OSC-16-T-R-ET CRSL/OSC-16-D 11710xx 1180023 CRPL/OSC-16 CRPL/OSC-16-ET CRPL/OSC-16-T 1080177 1081123 1080178 Remarks for installation in imc CRONOScompact, occupying 2 slots extended environmental temperature range with thermocouple sockets, for installation in imc CRONOScompact, occupying 3 slots (12 TE) extended environmental temperature range for installation imc CRONOScompact RACK, occupying 2 slots extended environmental temperature range with thermocouple sockets, for installation in imc CRONOScompact RACK, occupying 3 slots (12 TE) extended environmental temperature range for installation in imc CRONOS-SL with DSUB terminal connection, occupying 2 slots for installation in an imc CRONOS-PL, occupying 2 slots extended environmental temperature range with thermocouple sockets for installation in imc CRONOS-PL, occupying 2 slots (8TE) Errors and changes excepted For more information, contact: Berlin: +49 - 30 - 46 70 90 - 0 1 OSC-16 for imc CRONOS-PL/-SL/compact Technical Data Sheet CRPL/OSC-16-T-ET 04.10.2013 1081124 extended environmental temperature range Integrated sensor supply Version with an integrated sensor supply, requires no extra module expansion. With adjustable supply voltages (globally selectable for 8 channels), output on reserved pins of DSUB terminal. Required software version The module is fully supported by the imc operating software. Included accessories DSUB-15 connector ACC/DSUB(M)-T4: DSUB-15 plug with screw terminals for 4-channel measurement of voltages as well as temperatures with PT100 and thermocouples with integrated cold junction compensation (CJC). Included accessories for imc CRONOS-SL: ------ Optional accessories DSUB-15 connectors ACC/DSUB(M)-TEDS-T4 ACC/DSUB(M)-U4 ACC/DSUB(M)-TEDS-U4 ACC/DSUB(M)-I4 ACC/DSUB(M)-TEDS-I4 ACC/DSUB-ICP4 version with TEDS support, according to IEEE 1451.4 for use with imc Plug & Measure DSUB-15 plug with screw terminals for 4-channel voltage measurement DSUB-15 plug with screw terminals for 4-channel voltage measurement DSUB-15 plug with screw terminals for 4-channel current measurement of up to 50 mA (50 shunt, scaling factor: 0.02 A/V) version with TEDS support, according to IEEE 1451.4 for use with imc Plug & Measure DSUB-15 plug with screw terminals for conditioning of 4 IEPE/ICP inputs Errors and changes excepted For more information, contact: Berlin: +49 - 30 - 46 70 90 - 0 2 OSC-16 for imc CRONOS-PL/-SL/compact Technical Data Sheet 04.10.2013 Technical details - OSC-16 Data Sheet version 3.4 Parameter Value Inputs Remarks 16 Measurement mode DSUB voltage Standard plug (ACC/DSUB(M)-U4) current Current plug (ACC/DSUB(M)-I4) thermocouples, RTD (Pt100) Thermo-plug (ACC/DSUB(M)-T4) Measurement mode OSC-16-T thermocouples type-K Terminal connection 4x DSUB-15 or 16x thermo-sockets OSC-16-T Two pin thermo-sockets 4 channels per plug for thermocouples only Sampling rate, Bandwidth, Filter, TEDS Parameter Sampling rate Value Remarks max. 5 Hz (200 ms) / channel filter / bandwidth like at 2 Hz / 5 Hz, additional values are duplicated 10 Hz (100 ms) Bandwidth 1 Hz Resolution 16 Bit internal: 2 Hz (500 ms) with additional Interpolation; max. allowable input signal frequency: 1 Hz -0.01 dB Suppression @ 50 Hz (±2%) 5 Hz to 2 Hz (200 to 500 ms) 34 dB @ 49 Hz / 51 Hz 1 Hz (1 s) 68 dB @ 49 Hz / 51 Hz Bandwidth / noise suppression max. signal frequency Bandwidth max. Noise supp. 60 dB -1 dB signal (fg) (f_s) (f_filt) 1 Hz 50 Hz at sampling rate: 5 Hz (200 ms) 1.0 Hz 2 Hz (500 ms) 1.0 Hz 1 Hz 1 Hz (1 s) 0.5 Hz 0.5 Hz 48.5 Hz 0.5 Hz (2 s) 0.25 Hz 0.25 Hz 48.5 Hz Synchronicity (at sampling rate) f_s ... f_filt aliasing-free for frequencies above: f_filt 50 Hz Max. settling time aliasing only in the frequency range: max. 1 s constant time offset between two equally configured channels: (noise suppression 60 dB) sampling rate 5 Hz (200 ms) complete settling as a response to input step sampling rate 2 Hz (200 ms) max. 500 ms TEDS conform IEEE 1451.4 Class II MMI Errors and changes excepted For more information, contact: Berlin: +49 - 30 - 46 70 90 - 0 ACC/DSUB-TEDS(M)-xx 3 OSC-16 for imc CRONOS-PL/-SL/compact Technical Data Sheet 04.10.2013 General Parameter Value Remarks ±60 V channel to frame (housing, CHASSIS, protection ground) and channel to channel Isolation nominal test voltage 300 V (10 sec.) Overvoltage protection ±60 V diff. input voltage, (long term) ESD 2 kV human body model transient protection: automotive load dump ISO 7636, Test pulse 6 Input coupling Ri=30 , td=300 µs, tr<60 µs DC, isolated (differential) Input impedance Static input current Dynamic input current Test pulse 6 with max. -250 V electrical isolation to system-GND (housing, CHASSIS, protection ground) 10 M voltage mode (range ±2 V), temperature mode 1M voltage mode (range ±5 V) 50 Current mode (current connector) 1 nA (typ.) 10 nA (max.) settled, during sampling 0.1 mA (typ.) 1.5 mA (max.) peak dynamic input current value (typ. @100 mV, max. @2 V) 30 nA (typ.) 600 nA (max.) mean dynamic input current value (typ. @100 mV, max. @2 V) Input current below overvoltage 1.5 mA |Vin| > 7 V in the range ±2 V or device deactivated Sensor supply 5 V (DSUB-15) Parameter Value typ. min. / max. Auxiliary supply voltage available current internal resistance Remarks for IEPE (ICP)-extension plug +5 V >0.26 A 1.0 5% >0.2 A <1.2 independent of integrated sensor supply, short circuit proof power per DSUB-plug Voltage and current measurement Parameter Value typ. min. / max. Voltage input range 50 mV / 100 mV / 250 mV / 500 mV / 1 V / 2 V / 5 V / 10 V / 25 V / 50 V / 60 V Current input range 1 mA / 2 mA / 5 mA 10 mA / 20 mA / 40 mA Gain uncertainty Remarks with current connector (50 (ACC/DSUB-I4) shunt) <0.025 % <0.05 % <0.07 % <0.15 % voltage, 23 °C current with current connector <0.05 % of input range Offset <3 µV Non linearity < 30 ppm Gain drift Offset drift Noise voltage (RTI) range: 10 V 6 ppm/K ranges 2V 36 ppm/K ranges 5V 3 ppm/K <0.5 µVrms Errors and changes excepted For more information, contact: Berlin: +49 - 30 - 46 70 90 - 0 over entire temp. range over entire temperature range sampling rate 5 Hz (200 ms) 4 OSC-16 for imc CRONOS-PL/-SL/compact Technical Data Sheet 04.10.2013 Voltage and current measurement Parameter CMRR/ IMR (isolation mode rejection) Value typ. min. / max. <3.0 µVpkk (<1LSB) all sampling rates > 110 dB (50 Hz) range 2V > 95 dB (50 Hz) range 2V > 65 dB (50 Hz) range 5V Channel isolation < 50 pF, <100 nA Channel cross-talk damping all sampling rates Suppression of square edges on neighboring channels Remarks Rsource = 0 Rsource = 100 Rsource = 100 Channel to protection ground (CHASSIS); Channel-to-channel > 116 dB (50 Hz) range 2V > 101 dB (50 Hz) range 2V Rsource = 0 Rsource = 100 >123 dB @ sampling rate 200 ms range 2V Rsource = 100 Max. source impedance 5k Temperature measurement - Thermocouples Parameter typ. min. / max. Input range R, S, B, J, T, E, K, L, N Resolution 0.063 K (1/16 K) Uncertainty Drift < 0.5 K 0.05% 0.02 K/K Ta Remarks compliant with IEC 584 type-K, range -150°C to 1200°C plus value indicated Ta=|Ta -25°C|; Ta: ambient temp. Uncertainty of cold junction compensation Drift of cold junction temp. < 0.15 K DSUB (ACC/DSUB(M)-T4) < 0.5 K thermo plug (green) Typ K < 0.7 K thermo plug (white) with type K < 1K thermo plug (white) other types 0.001 K/K Tj Sensor breakage recognition Tj = |Tj -25°C| cold junction temp. Tj Display: “-2000°C” indicating unconnected input Temperature measurement – Pt100 (RTD) Parameter Input range typ. min. / max. Remarks -200°C to 850°C -200°C to +250°C Resolution 0.063 K (1/16 K) Uncertainty < 0.1 K 0.05% Drift Reference current (Pt100) 0.01 K/K Ta 250 µA Errors and changes excepted For more information, contact: Berlin: +49 - 30 - 46 70 90 - 0 -200°C to +850°C, 4-wire configuration plus indicated value Ta=|Ta -25°C|; Ta: ambient temperature non-isolated (CHASSIS is Ground) 5 OSC-16 for imc CRONOS-PL/-SL/compact Technical Data Sheet 04.10.2013 Technical Specs sensor SUPPLY module Parameter Configuration options Value (typ./ max.) 5 adjustable ranges Remarks The sensor supply module always got 5 selectable voltage ranges. Default ranges: +5 V to +24 V Output voltage Voltage Current Netpower (+2.5 V) +5.0 V +10 V +12 V +15 V +24 V ( 15 V) 580 mA 580 mA 300 mA 250 mA 200 mA 120 mA 190 mA 1.5 W 2.9 W 3.0 W 3.0 W 3.0 W 2.9 W 3.0 W Isolation Standard: option, upon request: non isolated isolated Short-circuit protection unlimited duration Accuracy of output voltage Efficiency Max. capacitive load special order, +12 V can be replaced by +2,5 V set globally for all channels of an amplifier. special order, +15 V can be replaced by 15 V output to case (CHASSIS) nominal rating: 50 V, Test voltage (10 sec.): 300 V, not available with option 15 V. to output voltage reference ground at terminals, no load <0.25% (typ.) <0.5% (max.) 25°C 25°C <0.9% (max ). over entire temperature range typ. 72% typ. 66% typ. 55% typ. 50% 10 V to 24 V none isolated 5V >4000 µF >1000 µF >300 µF 2.5 V to 10 V 12 V, 15 V 24 V 10 V to 24 V isolated 5V Errors and changes excepted For more information, contact: Berlin: +49 - 30 - 46 70 90 - 0 6