Pressure and Differential Pressure Transducer Construction The GEMÜ 3120 pressure and differential pressure transducer has an all plastic housing and is suitable for relative pressure / differential pressure measurements from 0-1 bar to 0-10 bar. The pick-up is temperature compensated and is available in various designs. The process connection is configured as standard with male threads to DIN 3852 or DIN 16288. The electrical connection is via a plug complying with DIN EN 175301-803 Form A. The transducer is calibrated at the factory and provides industrial standard measuring signals. Features • The pressure transducer converts the physical variable pressure proportionally into an electrical signal. • The differential pressure transducer measures the physical variable pressure at 2 measuring points and converts the differential into an electrical signal. Plus and minus differentials are evaluated. • GEMÜ 3120 is available as a 2 wire transducer (4-20 mA) and as a pressure measurement device with either current (0/4-20 mA) or relay output (adjustable MIN and MAX switch points). Advantages All plastic design Ceramic sensor with PTFE foil Linear output signal Simple mounting Fast response time Optional mounting position Minimum temperature influence Transducer dimensions code 600 [mm] Connection standard code 9A SW 19 27 H1 72 67 □50 H 63 H 88 92 H1 G G 1/4 G 1/2 39 • • • • • • • G SW 3120 Technical data Input parameters Measuring span Auxiliary power 0-10 bar (see order key) Overload limit see table 1 (page 3) Materials Materials of medium wetted parts Connecting element PVDF Sensor - Stainl. steel (code A0) Stainl. steel 1.4401/1.4301 - PTFE (code A3) PTFE foil 0.5 mm on ceramic sensor SealFPM 3120 2V Ambient temperature -10° C ... +50° C Medium temperature -10° C ... +60° C 2 wire transducer: Storage temperature -20° C ... +60° C Directives: EMC directive 89/336/EEC Low voltage directive 73/23/EEC Protection class IP 65 Materials of parts in contact with the ambience Connecting element PVDF HousingPP Housing cover of measurement device PSU Mechanical data Pressure connection Connecting element Torque Electrical connection Mounting position Weight 2 wire transducer Measurement device Differential pressure measurement device G1/4A to DIN 16288 G1/2A to DIN 16288 G1/4A to DIN 3852 G1/2A to DIN 3852 G3/4A to DIN 3852 max. 20 Nm Plug according to DIN EN 175301-803 Form A optional appr. 170 g appr. 300 g appr. 500 g ≤ 20 ms Temperature [°C] PVDF Maximum ripple 24V DC (+10%, -15%) / 50mA Ambient conditions 2 wire transducer Output span 4-20 mA Load impedance see characteristic Measurement device with current output Output span 0/4-20 mA Load impedance ≤ 750 Ω Voltage output 0-10 V upon request Measurement device with relay output Switching output 125 V AC / 0.6 A 110 V DC / 0.6 A 30 V DC / 2.0 A Switch points Min relay adjustable from 0-100% Max relay adjustable from 0-100% Hysteresis ±1% of measuring span Optical display Type LC display 3 1/2 digit Units bar, psi Functions (selection by switch) Display of measured value Switch point MIN relay Switch point MAX relay Accuracy ±0.5% of measuring span ±1 digit Temperature coefficient of zero output typ 0.2%/10K of measuring span Temperature coefficient of output span typ 0.2%/10K of measuring span Overload influence ≤ 0.1% of measuring span Characteristic deviation at limiting value adjustment - Sensor material (code A0) (incl. repeatability) ±0.5% of measuring span Hysteresis ±0.1% of measuring span - Sensor material (code A3) ± 1% of measuring span (incl. hysteresis and repeatability) Warming up time 5 min Material 15-35V DC Measurement device Output parameters Response time 2 wire transducer Code 20 Pressure / temperature correlation for PN 10 -20 -10 ±0 5 - 10,0 10,0 10,0 10 20 25 30 40 50 60 70 80 10,0 10,0 10,0 9,0 8,0 7,1 6,3 - - permissible operating pressure [bar] 2 Technical data Measure range Stainless steel (code A0) Overload min. Overload max. Bursting pressure PTFE (code A3) Max. medium temperature Overload min. [bar] [°C] rel.* abs. rel.*/abs. rel.*/abs. rel.* abs. 0 - 1,0 - 0,6 n.v. 4,0 7 60 0 - 1,6 - 0,6 n.v. 6,4 12 60 0 - 2,5 - 0,6 n.v. 10,0 16 60 - 0,7 n.v. 0 - 4,0 - 0,6 n.v. 16,0 16 60 - 0,7 n.v. 0 - 6,0 - 0,6 n.v. 16,0 25 60 - 0,7 n.v. 0 - 10,0 - 0,6 n.v. 16,0 25 25 - 0,7 n.v. * the differential pressure measurement device operates with relative pressure sensors n.v. = not available, can be used up to 10mbar/abs [bar] Load impedance 2 wire transducer Overload max. [bar] rel.*/abs. 12 12 16 16 Bursting pressure Max. medium temperature [°C] rel.*/abs. 16 16 25 25 60 60 60 25 Connection diagram Measurement device with relay output Supply voltage [VDC] 30 Supply voltage 1= GND 25 2= 24 V DC 20 Display changeover (in housing) 23 4 1 = Actual value 2 = MIN value 3 = MAX value 35 1 Sensor material Table 1: Measuring ranges / Sensor material 1 3 2 2 1 15 0 1000 500 Load impedance [Ohm] Signal output 1= MIN MIN-Relais MIN relay 3= MAX MAX relay MAX-Relais 2= Uv Connection diagram 2 wire transmitter 1 Connection diagram Measurement device with current output Supply voltage 2 1= GND 2= 24 V DC 24 V 1 3 2 2 1 Signal output 1= GND 2= 0/4 - 20 mA 3 3120 Order data Connection size Differential pressure measurement device 1/4“ (differential pressure) 1/2“ (differential pressure) Relative pressure measurement device 1/4“ (relative pressure) 1/2“ (relative pressure) 3/4“ (relative pressure) Absolute pressure measurement device 1/4“ (absolute pressure) 1/2“ (absolute pressure) 3/4“ (absolute pressure) Code TransducerCode DG1 DG2 600 2-wire transducer without display, Connection size code AG1-AG3/DG1-DG3 Measurement device with current output, 0-20 mA, with display Measurement device with current output, 0-20 mA, without display Measurement device with current output, 4-20 mA, with display Measurement device with current output, 4-20 mA ,without display Measurement device with relay output, with display G1 G2 G3 AG1 AG2 AG3 Connection type R Connection standard DIN 16288 (not for connection code AG3/G3) DIN 3852 Measuring range Sensor material 9B Connection type (code) 3120 012 0-36 psi 013 0-58 psi 014 0-87 psi 015 0-145 psi 016 0-0.25 MPa 023 0-0.4 MPa 024 0-0.6 MPa 025 0-1 MPa G1 R G1 R Connection standard (code) Connecting element material (code) Sensor material (code) Accuracy class (code) Transducer (code) Measuring range (code) 3120 011 0-23 psi (only sensor material code A0) D 3120 006 0-14 psi (only sensor material code A0) C (sensor material A3) 005 0-10 bar Code 0,5% (sensor material A0) 004 0-6 bar A3 Accuracy class 003 0-4 bar A0 Ceramic sensor, PTFE coated 002 0-2,5 bar Code Stainless steel 1.4401, 1.4301 Connection size (code) 621 630 001 0-1.6 bar (only sensor material code A0) 9A PVDF20 Type 620 Code 0-1 bar (only sensor material code A0) Code MaterialCode Order example 611 Code At rear of housing 1% 610 4 9A 9A 026 20 20 A3 A3 D D 600 600 006 006 Transducer dimensions code 600 [mm] Connection standard code 9A SW 19 27 H1 72 67 G G 1/4 G 1/2 G 3/4 SW 19 27 32 63 □50 H 82 79 83 H1 72 67 69 □50 H H1 H1 39 39 63 H 88 92 H G G 1/4 G 1/2 Transducer dimensions code 600 [mm] Connection standard code 9B FPM Ceramics KERAMIK FPM Stainl. steel 1.4301 FPM FPM Edelstahl 1.4301 Stainl. steel1.4401 1.4401 Edelstahl PTFE foil PTFE-Folie G SW PVDF PVDF G PVDF PVDF SW Sensor construction example, sensor material code A0 Sensor construction example, sensor material code A3 Transducer dimensions [mm] Code 610 / 611 / 620 / 621 / 630 / 631 Connection standard code 9A Transducer dimensions [mm] Code 610 / 611 / 620 / 621 / 630 Connection standard code 9B G G 1/4 G 1/2 SW 19 27 H 101 105 H1 85 80 G G 1/4 G 1/2 G 3/4 SW 19 27 32 H 95 92 96 H1 85 80 82 79 79 □83 H H H1 H1 52 52 □83 G SW G SW 5 3120 Dimensions Differential pressure measurement device Code 610 / 611 / 620 / 621 / 630 [mm] H1 108 103 G G 1/4 Connection standard code 9B SW 19 H 118 H1 108 79 □83 □83 H H1 H1 41 39 G G SW SW For further transducers, accessories and other products please see our Product Range catalogue and Price List. Contact GEMÜ. VALVES, MEASUREMENT AND CONTROL SYSTEMS GEMÜ Gebr. Müller · Apparatebau GmbH & Co. KG · Fritz-Müller-Str. 6-8 · D-74653 Ingelfingen-Criesbach · Tel. +49 (0) 7940/123-0 · Telefax +49 (0) 7940/123-224 info@gemue.de · www.gemu-group.com Should there be any doubts or misunderstandings, the German version of this data sheet is the authoritative document! 79 H 125 129 Subject to alteration · 05/2016 · 88051218 SW 19 27 Technical data sheet Connection standard code 9A H G G 1/4 G 1/2