Grundfos Direct Sensor - Mullarkey Associates, Inc.

GRUNDFOS PRODUCT GUIDE
Grundfos Direct Sensor™
Pressure transmitter
Grundfos Direct Sensor™
Table of contents
1.
2.
Pressure transmitter
3
Introduction
3
5.
6.
52
8.
Product range - RPS sensor
53
9.
Product range - DPS sensor
54
10. Product range - DPI transmitter V.2
55
11. Product range - DPI transmitter
56
12. Accessories
57
Sensor interface, type SI 001 PSU
13. Further product documentation
WebCAPS
WinCAPS
15
17
18
19
20
21
22
23
24
Differential pressure transmitter, industrial
(DPI)25
DPI general data
DPI 0-9 psi [0-0.6 bar]
DPI 0-14.5 psi [0-1.0 bar]
DPI 0-17.4 psi [0-1.2 bar]
DPI 0-25 psi [0-1.6 bar]
DPI 0-40 psi [0-2.5 bar]
DPI 0-60 psi [0-4.0 bar]
DPI 0-90 psi [0-6.0 bar]
DPI 0-145 psi [0-10.0 bar]
25
27
28
29
30
31
32
33
34
Relative pressure sensor standard (RPS)
35
RPS general data
RPS 0-9 psi [0-0.6 bar]
RPS 0-14.5 psi [0-1.0 bar]
RPS 0-25 psi [0-1.6 bar]
RPS 0-40 psi [0-2.5 bar]
RPS 0-60 psi [0-4.0 bar]
RPS 0-90 psi [0-6.0 bar]
RPS 0-145 psi [0-10.0 bar]
35
37
38
39
40
41
42
43
Differential pressure sensor, standard (DPS)44
DPS general data
DPS 0-9 psi [0-0.6 bar]
DPS 0-14.5 psi [0-1.0 bar]
DPS 0-25 psi [0-1.6 bar]
DPS 0-40 psi [0-2.5 bar]
DPS 0-60 psi [0-4.0 bar]
DPS 0-90 psi [0-6.0 bar]
2
4
6
7
8
9
10
11
12
13
14
Differential pressure transmitter, industrial
(DPI) V.215
DPI V.2 general data
DPI 0-9 psi [0-0.6 bar]
DPI 0-14.5 psi
DPI 0-25 psi [0-1.6 bar]
DPI 0-40 psi [0-2.5 bar]
DPI 0-60 psi [0-4.0 bar]
DPI 0-90 psi [0-6.0 bar]
DPI 0-145 psi [0-10.0 bar]
DPI 0-232 psi [0-16.0 bar]
4.
Product range-RPI Transmitter
Relative pressure transmitter, industrial (RPI)4
RPI general data
RPI 0-9 psi [0-0.6 bar]
RPI 0-14.5 psi [0-1.0 bar]
RPI 0-25 psi [0-1.6 bar]
RPI 0-40 psi [0-2.5 bar]
RPI 0-60 psi [0-4.0 bar]
RPI 0-90 psi [0-6.0 bar]
RPI 0-145 psi [0-10.0 bar]
RPI 0-232 psi [0-16.0 bar]
RPI 0-360 psi [0-25.0 bar],
3.
7.
44
46
47
48
49
50
51
57
58
58
59
1
Grundfos Direct Sensor™
Introduction
Pressure transmitter
1. Pressure transmitter
pressure, will cause the sensor chip to warp. The
warping is registered as a change of resistance in the
strain gauges of a Wheatstone bridge. The change in
resistance is converted into an analogue output signal.
The DPI+T also transforms the temperature of the
medium into an electrical signal.
This Product guide describes Grundfos pressure
transmitters.
Fig. 1
TM03 4055 1406
TM04 5034 / TM04 7865 / TM04 7866
.
Grundfos pressure transmitters
The three pressure measuring methods are absolute,
relative and differential pressure.
• Absolute pressure is zero referenced against a
perfect vacuum.
• Relative pressure is zero referenced against
ambient air pressure.
• Differential pressure is the difference between two
pressures
The Grundfos pressure transmitter range contains both
relative and differential pressure transmitters. The
combination of the temperature transmitter with either
the relative or differential pressure transmitter are able
to measure temperatures in the range of -22 to 248 °F
[-30 to 120 °C].
Relative Pressure Transmitter (RPI)
The central part of the relative pressure transmitter is a
sensor chip, which transforms the pressure into
electrical signals. The pressure differences between
the ambient pressure and the measured pressure will
cause the sensor chip to warp. The warping is
registered as a change of resistance in the strain
gauges of a Wheatstone bridge. The change in
resistance is converted into an analogue output signal.
The RPI+T will also transform the temperature of the
medium into electrical signals.
The signals are calibrated, conditioned and presented
in analogue or digital format by means of a
microprocessor. The pressure signals are temperature
compensated and linearized for the influence of
temperature variations.
Fig. 2
Schematic view of how the sensor chip is affected
by pressure on both sides.
Sensor chip
Steady state properties of silicon protects the sensor
chip against wear and tear. Lifelong nano-coating
protection enables for the first time, direct
measurement (wet and wet-wet) in a cost effective
packaging for aggressive media. The secret is a metalglass alloy coating, Silicoat® with an extreme
resistance to corrosion. Compared to traditional sensor
technologies which encapsulate the unprotected
measuring cell from the Media, Silicoat® ensures a
continuous protection of the Sensor Chip in aggressive
media (ph 2-ph 11) at temperatures up to 248 °F
[120 °C].
The trademark for Grundfos Direct Sensorsറ is owned
and controlled by the Grundfos group.
Differential Pressure transmitter (DPI and
DPS)
The central part of the differential pressure transmitter
is a sensor chip, which transforms the differential
pressure into electrical signals. The difference
between the two pressures, called the differential
3
2
Grundfos Direct Sensor™
Relative pressure transmitter, industrial (RPI)
2. Relative pressure transmitter, industrial (RPI)
RPI general data
Features
• Pressure ranges: 9 to 360 psi [0.6 to 25.0 bar]
• M12 connector
• approved for potable water: WRAS (pending),
KTW (pending), ACS (pending)
• wide temperature range -22 to 248 °F [-30 to
120 °C] (RPI+T).
• Max cable length (industry): 100 ft [30 meters]*
Relative pressure transmitter, Industrial
TM04 7865 2510
Benefits
Fig. 3
RPI/RPI+T transmitter
Technical overview
Grundfos Direct Sensorsറ, type RPI, are an industrial
relative pressure transmitter designed to be mounted
directly in the pipe system or application. The RPI+T
version can also measure temperature in the range
-22 to 248 °F [-30 to 120 °C]
Sensor chip
Steady state properties of silicon protects the sensor
chip against wear and tear. Lifelong nano-coating
protection enables for the first time, direct
measurement (wet and wet-wet) in a cost effective
packaging for aggressive media. The secret is a metalglass alloy coating, Silicoat® with an extreme
resistance to corrosion. Compared to traditional sensor
technologies which encapsulate the unprotected
measuring cell from the Media, Silicoat® ensures a
continuous protection of the Sensor Chip in aggressive
media (ph 2-ph 11) at temperatures up to 248 °F
[120 °C].
Applications
•
•
•
•
•
•
•
•
•
4
Water treatment and distribution
light chemical industry
water management
pool and water resort
heat pump
HVAC
cooling towers
condensing units
solar system.
•
•
•
•
•
No moving parts
compatible with wet, aggressive media
cost-effective and robust construction
system solution with Grundfos pumps
pressure and temperature measurement in one
transmitter (RPI+T).
2
Grundfos Direct Sensor™
Type designation
RPI
+T
0-6
Relative pressure transmitter, industrial (RPI)
Type key
G½" 020 E ,Set
Product group:
RPI: Relative pressure
transmitter, industrial
Temperature sensor:
+T = with temperature sensor
Pressure range:
0-6 = 0-6 bar 0-9 psi
Thread size
Output signal:
020 = 4-20 mA
O-ring material:
E = EPDM
F = FKM
Set = Complete pressure transmitter
Electrical connections
2
1
TM04 7156 1610
4
3
Fig. 4
*
*
Electrical connections
PIN
1
2
3
4
Wire color
Brown
Grey
Blue
Black
Output
4 to 20 mA
+
not used
-
not used
Output
2 x 0 to 10 V
+
Pressure
signal
-*
Temperature
signal
Common ground for both pressure and temperature signal.
Power supply (screened cable): SELV or PELV.
Approvals
•
•
•
•
•
WRAS
KTW
ACS
NSF 61
EU, US, and Canadian markets
*Grundfos will not be liable for damage or wear to
products caused by abnormal operating conditions,
accident abuse, misuse unauthorized alteration or
repair, or if the product was not installed in accordance
with Grundfos' printed installation and operating
instructions. Splicing of the supplied cable would void
any warranty.
5
2
Grundfos Direct Sensor™
Relative pressure transmitter, industrial (RPI)
RPI 0-9 psi [0-0.6 bar]
Specifications
Relative pressure transmitter, industrial 0-9 psi
Pressure
TM04 9240 3510
Measuring range
Accuracy (± 1˰), 32 to 176 °F
[0 to 80 °C]
Accuracy (± 1˰), -22 to 212 °F
[-30 to 100 °C]
Response time
Resolution
Fig. 5
RPI/RPI+T
Dimensions
0 to 9 psi [0 to 0.6 bar]
± 2 % FS
± 2.5 % FS
< 100 ms (typical 50 ms)
1/1000 FS
Temperature (Only RPI with temperature sensor)
Range (relative)
Accuracy (± 1ı), 32 to 176 °F
[0 to 80 °C]
Accuracy (± 1ı), 32 to 212 °F
[0 to 100 °C]
Accuracy (± 1ı), 32 to 248 °F
[0 to 120 °C]
Response time for sensor
electronics
Resolution
-22 to 248 °F [-30 to 120 °C]
± 1.8 °F [± 1 °C]
± 3.6 °F [± 2 °C]
± 5.4 °F [± 2.5 °C]
< 100 ms (typical 50 ms)
0.18 °F [0.1 °C]
Media and environment
4.33 in.
ISO 228 - G1/2
1.45 in.
Fig. 6
TM04 9237 1612
1/8" NPT
Dimensions RPI transmitter
Media types
Media temperature (operation)
Ambient air temperature
(operation)
Storage temperature
Humidity
System burst pressure
liquids, gasses and air
-22 to 248 °F [-30 to 120 °C]
-13 to 140 °F [-25 to 60 °C]
-67 to 158 °F [-55 to 70 °C]
0 to 95 % RH, non-condensing
870 psi [60 bar]
Electrical data (Only RPI without temperature sensor)
Power supply RPI
Output signals - cut off
Power consumption
Sensor output signals
Load impedance
12 to 30 VDC
4 to 20 mA
660 mW
max. 60 ˖ at 12.5 VDC
max. 100 ˖ at 13.3 VDC
m.ax 900 ˖ at 30 VDC
Electrical data (Only RPI with temperature sensor)
20 mA
Power supply RPI + T
Output signals
Max. signal cable length
Power consumption
Load impedance
16.6 to 30 VDC
0 to 10 VDC
98 ft [30 m]
450 mW
min. 10 k˖
4 mA
9 psi [0.6 bar]
0
Fig. 7
TM04 9189 3610
Sensor materials
Pressure response of RPI 0-9 psi
Fig. 8
6
Wetted materials
Enclosure class
Temperature cycling
Vibration (non-destructive)
Electromagnetic compatibility
9 psi [0.6 bar]
212 °F [100 °C]
Pressure and temperature response of RPI + T
TM04 91890 3610
0
32 °F [0 °C]
silicon-based MEMS sensor
EPDM or FKM rubber
stainless steel AISI 316 L
corrosion-resistant coating
EPDM or FKM rubber
stainless steel AISI 316 L
Environmental standards
10 V
0V
Measurement element
Packing material
Sensor housing
IP67
IEC 68-2-14
20 to 2000 Hz, 10G, 4h
EN 61326-1
2
RPI 0-14.5 psi [0-1.0 bar]
Specifications
Relative pressure transmitter, industry 0-14.5 psi
Pressure
TM04 9240 3510
Measuring range
Accuracy (± 1˰), 32 to 176 °F
[0 to 80 °C]
Accuracy (± 1˰), -22 to 212 °F
[-30 to 100 °C]
Response time
Resolution
Fig. 9
RPI/RPI+T 0-14.5 psi transmitter
Dimensions
Relative pressure transmitter, industrial (RPI)
Grundfos Direct Sensor™
0 to 14.5 psi [0 to 1.0 bar]
± 2 % FS
± 2.5 % FS
< 100 ms (typical 50 ms)
1/1000 FS
Temperature (Only RPI with temperature sensor)
Range (relative)
Accuracy (± 1ı), 32 to 176 °F
[0 to 80 °C]
Accuracy (± 1ı), 32 to 212 °F
[0 to 100 °C]
Accuracy (± 1ı), -22 to 212 °F
[-30 to 100 °C]
Response time for sensor
electronics
Resolution
-22 to 212 °F [-30 to 100 °C]
± 1.8 °F [± 1 °C]
± 3.6 °F [± 2 °C]
± 5.4 °F [± 2.5 °C]
< 100 ms (typical 50 ms)
0.18 °F [0.1 °C]
Media and environment
4.33 in.
ISO 228 - G1/2
1.45 in.
TM04 9237 1612
1/8" NPT
Fig. 10 Dimensions RPI transmitter
Sensor output signals
Media types
Media temperature (operation)
Ambient air temperature
(operation)
Storage temperature
Humidity
System burst pressure
liquids, gasses and air
-22 to 212 °F [-30 to 100 °C]
-13 to 140 °F [-25 to 95 °C]
-67 to 158 °F [-55 to 70 °C]
0 to 95 % RH, non-condensing
870 psi [60 bar]
Electrical data (Only RPI without temperature sensor)
Power supply RPI
Output signals
Power consumption
Load impedance
12 to 30 VDC
4 to 20 mA
660 mW
max. 60 ˖ at 12.5 VDC
max. 100 ˖ at 13.3 VDC
m.ax 900 ˖ at 30 VDC
Electrical data (Only RPI with temperature sensor)
Power supply RPI + T
Output signals
Max. signal cable length
Power consumption
Load impedance
4 mA
0
14.5 psi [1.0 bar]
TM04 9189 3610
20
16.6 to 30 VDC
0 to 10 VDC
98 ft [30 m]
450 mW
min. 10 k˖
Sensor materials
Measurement element
Packing material
Sensor housing
Wetted materials
Fig. 11 Pressure response RPI 0-14.5 psi
silicon-based MEMS sensor
EPDM or FKM rubber
stainless steel AISI 316 L
corrosion-resistant coating
EPDM or FKM rubber
stainless steel AISI 316 L
Environmental standards
Enclosure class
Temperature cycling
Vibration (non-destructive)
Electromagnetic compatibility
0V
0
32 °F [0 °C]
14.5 psi [1.0 bar]
212 °F [100 °C]
IP67
IEC 68-2-14
20 to 2000 Hz, 10G, 4h
EN 61326-1
TM04 91890 3610
10 V
Fig. 12 Pressure and temperature response RPI +T
7
2
Grundfos Direct Sensor™
Relative pressure transmitter, industrial (RPI)
RPI 0-25 psi [0-1.6 bar]
Specifications
Relative pressure transmitter, industry 0-25 psi
Pressure
Measuring range
Accuracy (± 1˰), 32 to 176 °F
[0 to 80 °C]
Accuracy (± 1˰), -22 to 212 °F
[-30 to 100 °C]
TM04 9240 3510
Response time
Fig. 13 RPI/RPI+T 0-25 psi transmitter
Dimensions
Resolution
0 to 25 psi [0 to 1.6 bar]
± 2 % FS
± 2.5 % FS
< 100 ms
(typical 50 ms)
1/1000 FS
Temperature (Only RPI with temperature sensor)
Range (relative)
Accuracy (± 1ı), 32 to 176 °F
[0 to 80 °C]
Accuracy (± 1ı), 32 to 212 °F
[0 to 100 °C]
Accuracy (± 1ı), -22 to 212 °F
[-30 to 100 °C]
Response time for sensor
electronics
Resolution
-22 to 212 °F [-30 to 100 °C]
± 1.8 °F [± 1 °C]
± 3.6 °F [± 2 °C]
± 5.4 °F [± 2.5 °C]
< 100 ms
(typical 50 ms)
0.18 °F [0.1 °C]
Media and environment
4.33 in.
ISO 228 - G1/2
1.45 in.
TM04 9237 1612
1/8" NPT
Fig. 14 Dimensions RPI transmitter
Media types
Media temperature (operation)
Ambient air temperature
(operation)
Storage temperature
Humidity
System burst pressure
liquids, gasses and air
-22 to 212 °F [-30 to 100 °C]
-13 to 140 °F [-25 to 95 °C]
-67 to 158 °F [-55 to 70 °C]
0 to 95 % RH, non-condensing
870 psi [60 bar]
Electrical data (Only RPI without temperature sensor)
Power supply RPI
Output signals - cut off
Power consumption
Sensor output signals
Load impedance
12 to 30 VDC
4 to 20 mA
660 mW
max. 60 ˖ at 12.5 VDC
max. 100 ˖ at 13.3 VDC
m.ax 900 ˖ at 30 VDC
Electrical data (Only RPI with temperature sensor)
20 mA
4 mA
0
25 psi [1.6 bar]
TM04 9189 3610
Power supply RPI + T
Output signals
Max. signal cable length
Power consumption
Load impedance
16.6 to 30 VDC
0 to 10 VDC
98 ft [30 m]
450 mW
min. 10 k˖
Sensor materials
Measurement element
Packing material
Sensor housing
Wetted materials
Fig. 15 Pressure response RPI 0-25 psi
silicon-based MEMS sensor
EPDM or FKM rubber
stainless steel AISI 316 L
corrosion-resistant coating
EPDM or FKM rubber
stainless steel AISI 316 L
Environmental standards
Enclosure class
Temperature cycling
Vibration (non-destructive)
Electromagnetic compatibility
0V
0
32 °F [0 °C]
25 psi [1.6 bar]
212 °F [100 °C]
Fig. 16 Pressure and temperature response RPI +T
8
TM04 91890 3610
10 V
IP67
IEC 68-2-14
20 to 2000 Hz, 10G, 4h
EN 61326-1
2
RPI 0-40 psi [0-2.5 bar]
Specifications
Relative pressure transmitter, industry 0-40 psi
Pressure
TM04 9240 3510
Measuring range
Accuracy (± 1˰), 32 to 176 °F
[0 to 80 °C]
Accuracy (± 1˰), -22 to 212 °F
[-30 to 100 °C]
Response time
Resolution
Fig. 17 RPI/RPI+T 0-40 psi transmitter
Dimensions
Relative pressure transmitter, industrial (RPI)
Grundfos Direct Sensor™
0 to 40 psi [0 to 2.5 bar]
± 2 % FS
± 2.5 % FS
< 100 ms (typical 50 ms)
1/1000 FS
Temperature (Only RPI with temperature sensor)
Range (relative)
Accuracy (± 1ı), 32 to 176 °F
[0 to 80 °C]
Accuracy (± 1ı), 32 to 212 °F
[0 to 100 °C]
Accuracy (± 1ı), -22 to 212 °F
[-30 to 100 °C]
Response time for sensor
electronics
Resolution
-22 to 212 °F [-30 to 100 °C]
± 1.8 °F [± 1 °C]
± 3.6 °F [± 2 °C]
± 5.4 °F [± 2.5 °C]
< 100 ms
(typical 50 ms)
0.18 °F [0.1 °C]
Media and environment
4.33 in.
ISO 228 - G1/2
1.45 in.
TM04 9237 1612
1/8" NPT
Fig. 18 Dimensions RPI transmitter
Sensor output signals
Media types
Media temperature (operation)
Ambient air temperature
(operation)
Storage temperature
Humidity
System burst pressure
liquids, gasses and air
-22 to 212 °F [-30 to 100 °C]
-13 to 140 °F [-25 to 95 °C]
-67 to 158 °F [-55 to 70 °C]
0 to 95 % RH, non-condensing
870 psi [60 bar]
Electrical data (Only RPI without temperature sensor)
Power supply RPI
Output signals
Power consumption
Load impedance
12 to 30 VDC
4 to 20 mA
660 mW
max. 60 ˖ at 12.5 VDC
max. 100 ˖ at 13.3 VDC
m.ax 900 ˖ at 30 VDC
Electrical data (Only RPI with temperature sensor)
Power supply RPI + T
Output signals
Max. signal cable length
Power consumption
Load impedance
20 mA
16.6 to 30 VDC
0 to 10 VDC xxx
98 ft [30 m]
450 mW
min. 10 k˖
4 mA
0
40 psi [2.5 bar]
TM04 9189 3610
Sensor materials
Fig. 19 Pressure response of RPI 0-40 psi
Wetted materials
Enclosure class
Temperature cycling
Vibration (non-destructive)
Electromagnetic compatibility
40 psi [2.5 bar]
212 °F [100 °C]
IP67
IEC 68-2-14
20 to 2000 Hz, 10G, 4h
EN 61326-1
TM04 91890 3610
0
32 °F [0 °C]
silicon-based MEMS sensor
EPDM or FKM rubber
stainless steel AISI 316 L
corrosion-resistant coating
EPDM or FKM rubber
stainless steel AISI 316 L
Environmental standards
10 V
0V
Measurement element
Packing material
Sensor housing
Fig. 20 Pressure and temperature response of RPI +T
9
2
Grundfos Direct Sensor™
Relative pressure transmitter, industrial (RPI)
RPI 0-60 psi [0-4.0 bar]
Specifications
Relative pressure transmitter, industry 0-60 psi
Pressure
TM04 9240 3510
Measuring range
Accuracy (± 1˰), 32 to 176 °F
[0 to 80 °C]
Accuracy (± 1˰), -22 to 212 °F
[-30 to 100 °C]
Response time
Resolution
Fig. 21 RPI/RPI+T 0-60 psi transmitter
Dimensions
0 to 60 psi [0 to 4.0 bar]
± 2 % FS
± 2.5 % FS
< 100 ms (typical 50 ms)
1/1000 FS
Temperature (Only RPI with temperature sensor)
Range (relative)
Accuracy (± 1ı), 32 to 176 °F
[0 to 80 °C]
Accuracy (± 1ı), 32 to 212 °F
[0 to 100 °C]
Accuracy (± 1ı), -22 to 212 °F
[-30 to 100 °C]
Response time for sensor
electronics
Resolution
-22 to 212 °F [-30 to 100 °C]
± 1.8 °F [± 1 °C]
± 3.6 °F [± 2 °C]
± 5.4 °F [± 2.5 °C]
< 100 ms (typical 50 ms)
0.18 °F [0.1 °C]
Media and environment
4.33 in.
ISO 228 - G1/2
1.45 in.
TM04 9237 1612
1/8" NPT
Fig. 22 Dimensions RPI transmitter
Sensor output signals
Media types
Media temperature (operation)
Ambient air temperature
(operation)
Storage temperature
Humidity
System burst pressure
liquids, gasses and air
-22 to 212 °F [-30 to 100 °C]
-13 to 140 °F [-25 to 95 °C]
-67 to 158 °F [-55 to 70 °C]
0 to 95 % RH, non-condensing
870 psi [60 bar]
Electrical data (Only RPI without temperature sensor)
Power supply RPI
Output signals - cut off
Power consumption
Load impedance
12 to 30 VDC
4 to 20 mA
660 mW
max. 60 ˖ at 12.5 VDC
max. 100 ˖ at 13.3 VDC
m.ax 900 ˖ at 30 VDC
Electrical data (Only RPI with temperature sensor)
Power supply RPI + T
Output signals
Max. signal cable length
Power consumption
Load impedance
20 mA
16.6 to 30 VDC
0 to 10 VDC
98 ft [30 m]
450 mW
min. 10 k˖
4 mA
0
60 psi [4.0 bar]
TM04 9189 3610
Sensor materials
Fig. 23 Pressure response of RPI 0-60 psi
Enclosure class
Temperature cycling
Vibration (non-destructive)
Electromagnetic compatibility
60 psi [4.0 bar]
212 °F [100 °C]
TM04 91890 3610
0
32 °F [0 °C]
Fig. 24 Pressure and temperature response of RPI +T
10
Wetted materials
silicon-based MEMS sensor
EPDM or FKM rubber
stainless steel AISI 316 L
corrosion-resistant coating
EPDM or FKM rubber
stainless steel AISI 316 L
Environmental standards
10 V
0V
Measurement element
Packing material
Sensor housing
IP67
IEC 68-2-14
20 to 2000 Hz, 10G, 4h
EN 61326-1
2
RPI 0-90 psi [0-6.0 bar]
Specifications
Relative pressure transmitter, industry 0-90 psi
Pressure
TM04 9240 3510
Measuring range
Accuracy (± 1˰), 32 to 176 °F
[0 to 80 °C]
Accuracy (± 1˰), -22 to 212 °F
[-30 to 100 °C]
Response time
Resolution
Fig. 25 RPI/RPI+T 0-90 psi transmitter
Dimensions
Relative pressure transmitter, industrial (RPI)
Grundfos Direct Sensor™
0 to 90 psi [0 to 6.0 bar]
± 2 % FS
± 2.5 % FS
< 100 ms (typical 50 ms)
1/1000 FS
Temperature (Only RPI with temperature sensor)
Range (relative)
Accuracy (± 1ı), 32 to 176 °F
[0 to 80 °C]
Accuracy (± 1ı), 32 to 212 °F
[0 to 100 °C]
Accuracy (± 1ı), -22 to 212 °F
[-30 to 100 °C]
Response time for sensor
electronics
Resolution
-22 to 212 °F [-30 to 100 °C]
± 1.8 °F [± 1 °C]
± 3.6 °F [± 2 °C]
± 5.4 °F [± 2.5 °C]
< 100 ms (typical 50 ms)
0.18 °F [0.1 °C]
Media and environment
4.33 in.
ISO 228 - G1/2
1.45 in.
TM04 9237 1612
1/8" NPT
Fig. 26 Dimensions RPI transmitter
Sensor output signals
Media types
Media temperature (operation)
Ambient air temperature
(operation)
Storage temperature
Humidity
System burst pressure
liquids, gasses and air
-22 to 212 °F [-30 to 100 °C]
-13 to 140 °F [-25 to 95 °C]
-67 to 158 °F [-55 to 70 °C]
0 to 95 % RH, non-condensing
870 psi [60 bar]
Electrical data (Only RPI without temperature sensor)
Power supply RPI
Output signals
Power consumption
Load impedance
12 to 30 VDC
4 to 20 mA
660 mW
max. 60 ˖ at 12.5 VDC
max. 100 ˖ at 13.3 VDC
m.ax 900 ˖ at 30 VDC
Electrical data (Only RPI with temperature sensor)
Power supply RPI + T
Output signals
Max. signal cable length
Power consumption
Load impedance
20 mA
16.6 to 30 VDC
0 to 10 VDC
98 ft [30 m]
450 mW
min. 10 k˖
4 mA
0
90 psi [6.0 bar]
TM04 9189 3610
Sensor materials
Fig. 27 Pressure response of RPI 0-90 psi
Wetted materials
Enclosure class
Temperature cycling
Vibration (non-destructive)
Electromagnetic compatibility
90 psi [6.0 bar]
212 °F [100 °C]
IP67
IEC 68-2-14
20 to 2000 Hz, 10G, 4h
EN 61326-1
TM04 91890 3610
0
32 °F [0 °C]
silicon-based MEMS sensor
EPDM or FKM rubber
stainless steel AISI 316 L
corrosion-resistant coating
EPDM or FKM rubber
stainless steel AISI 316 L
Environmental standards
10 V
0V
Measurement element
Packing material
Sensor housing
Fig. 28 Pressure and temperature response of RPI +T
11
2
Grundfos Direct Sensor™
Relative pressure transmitter, industrial (RPI)
RPI 0-145 psi [0-10.0 bar]
Specifications
Relative pressure transmitter, industry 0-145 psi
Pressure
TM04 9240 3510
Measuring range
Accuracy (± 1˰), 32 to 176 °F
[0 to 80 °C]
Accuracy (± 1˰), -22 to 212 °F
[-30 to 100 °C]
Response time
Resolution
Fig. 29 RPI/RPI+T 0-145 psi transmitter
Dimensions
0 to 145 psi [0 to 10 bar]
± 2 % FS
± 2.5 % FS
< 100 ms (typical 50 ms)
1/1000 FS
Temperature (Only RPI with temperature sensor)
Range (relative)
Accuracy (± 1ı), 32 to 176 °F
[0 to 80 °C]
Accuracy (± 1ı), 32 to 212 °F
[0 to 100 °C]
Accuracy (± 1ı), -22 to 212 °F
[-30 to 100 °C]
Response time for sensor
electronics
Resolution
-22 to 212 °F [-30 to 100 °C]
± 1.8 °F [± 1 °C]
± 3.6 °F [± 2 °C]
± 5.4 °F [± 2.5 °C]
< 100 ms (typical 50 ms)
0.18 °F [0.1 °C]
Media and environment
4.33 in.
ISO 228 - G1/2
1.45 in.
TM04 9237 1612
1/8" NPT
Fig. 30 Dimensions RPI transmitter
Sensor output signals
Media types
Media temperature (operation)
Ambient air temperature
(operation)
Storage temperature
Humidity
System burst pressure
liquids, gasses and air
-22 to 212 °F [-30 to 100 °C]
-13 to 140 °F [-25 to 95 °C]
-67 to 158 °F [-55 to 70 °C]
0 to 95 % RH, non-condensing
870 psi [60 bar]
Electrical data (Only RPI without temperature sensor)
Power supply RPI
Output signals
Power consumption
Load impedance
12 to 30 VDC
4 to 20 mA
660 mW
max. 60 ˖ at 12.5 VDC
max. 100 ˖ at 13.3 VDC
m.ax 900 ˖ at 30 VDC
Electrical data (Only RPI with temperature sensor)
Power supply RPI + T
Output signals
Max. signal cable length
Power consumption
Load impedance
20 mA
16.6 to 30 VDC
0 to 10 VDC
98 ft [30 m]
450 mW
min. 10 k˖
4 mA
0
145psi [10.0 bar]
TM04 9189 3610
Sensor materials
Enclosure class
Temperature cycling
Vibration (non-destructive)
Electromagnetic compatibility
0
32 °F [0 °C]
145 psi [10 bar]
212 °F [100 °C]
Fig. 32 Pressure and temperature response of
RPI +T 0-10.0
TM04 91890 3610
10 V
12
Wetted materials
silicon-based MEMS sensor
EPDM or FKM rubber
stainless steel AISI 316 L
corrosion-resistant coating
EPDM or FKM rubber
stainless steel AISI 316 L
Environmental standards
Fig. 31 Pressure response of RPI 0-145 psi
0V
Measurement element
Packing material
Sensor housing
IP67
IEC 68-2-14
20 to 2000 Hz, 10G, 4h
EN 61326-1
2
RPI 0-232 psi [0-16.0 bar]
Specifications
Relative pressure transmitter, industry 0-232 psi
Pressure
TM04 9240 3510
Measuring range
Accuracy (± 1˰), 32 to 176 °F
[0 to 80 °C]
Accuracy (± 1˰), -22 to 212 °F
[-30 to 100 °C]
Response time
Resolution
Fig. 33 RPI/RPI+T 0-232 psi transmitter
Dimensions
Relative pressure transmitter, industrial (RPI)
Grundfos Direct Sensor™
0 to 232 psi [0-16 bar]
± 2.5 % FS
± 3 % FS
< 100 ms (typical 50 ms)
1/1000 FS
Temperature (Only RPI with temperature sensor)
Range (relative)
Accuracy (± 1ı), 32 to 176 °F
[0 to 80 °C]
Accuracy (± 1ı), 32 to 212 °F
[0 to 100 °C]
Accuracy (± 1ı), -22 to 212 °F
[-30 to 100 °C]
Response time for sensor
electronics
Resolution
-22 to 212 °F [-30 to 100 °C]
± 1.8 °F [± 1 °C]
± 3.6 °F [± 2 °C]
± 5.4 °F [± 2.5 °C]
< 100 ms (typical 50 ms)
0.18 °F [0.1 °C]
Media and environment
4.33 in.
ISO 228 - G1/2
1.45 in.
TM04 9237 1612
1/8" NPT
Fig. 34 Dimensions RPI transmitter
Sensor output signals
Media types
Media temperature (operation)
Ambient air temperature
(operation)
Storage temperature
Humidity
System burst pressure
liquids, gasses and air
-22 to 212 °F [-30 to 100 °C]
-13 to 140 °F [-25 to 95 °C]
-67 to 158 °F [-55 to 70 °C]
0 to 95 % RH, non-condensing
870 psi [60 bar]
Electrical data (Only RPI without temperature sensor)
Power supply RPI
Output signals
Power consumption
Load impedance
12 to 30 VDC
4 to 20 mA
660 mW
max. 60 ˖ at 12.5 VDC
max. 100 ˖ at 13.3 VDC
m.ax 900 ˖ at 30 VDC
Electrical data (Only RPI with temperature sensor)
20 mA
4 mA
0
232 psi [16 bar]
TM04 9189 3610
Power supply RPI + T
Output signals
Max. signal cable length
Power consumption
Load impedance
16.6 to 30 VDC
0 to 10 VDC
98 ft [30 m]
450 mW
min. 10 k˖
Sensor materials
Measurement element
Packing material
Sensor housing
Wetted materials
Fig. 35 Pressure response of RPI 0-232 psi
silicon-based MEMS sensor
EPDM or FKM rubber
stainless steel AISI 316 L
corrosion-resistant coating
EPDM or FKM rubber
stainless steel AISI 316 L
Environmental standards
Enclosure class
Temperature cycling
Vibration (non-destructive)
Electromagnetic compatibility
0V
032 °F [0 °C]
232 psi [16 bar]
212 °F [100 °C]
TM04 91890 3610
10 V
IP67
IEC 68-2-14
20 to 2000 Hz, 10G, 4h
EN 61326-1
Fig. 36 Pressure and temperature response of RPI +T
13
2
Grundfos Direct Sensor™
Relative pressure transmitter, industrial (RPI)
RPI 0-360 psi [0-25.0 bar],
Specifications
Relative pressure transmitter, industry 0-360 psi
Pressure
TM04 9240 3510
Measuring range
Accuracy (± 1˰), 32 to 176 °F
[0 to 80 °C]
Accuracy (± 1˰), -22 to 212 °F
[-30 to 100 °C]
Response time
Resolution
Fig. 37 RPI/RPI+T 0-360 psi transmitter
Dimensions
0 to 360 psi [0 to 25 bar]
± 2.5 % FS
± 3 % FS
< 100 ms (typical 50 ms)
1/1000 FS
Temperature (Only RPI with temperature sensor)
Range (relative)
Accuracy (± 1ı), 32 to 176 °F
[0 to 80 °C]
Accuracy (± 1ı), 32 to 212 °F
[0 to 100 °C]
Accuracy (± 1ı), -22 to 212 °F
-30 to 100 °C]
Response time for sensor
electronics
Resolution
-22 to 212 °F [-30 to 100 °C]
± 1.8 °F [± 1 °C]
± 3.6 °F [± 2 °C]
± 5.4 °F [± 2.5 °C]
< 100 ms (typical 50 ms)
0.18 °F [0.1 °C]
Media and environment
4.33 in.
ISO 228 - G1/2
1.45 in.
TM04 9237 1612
1/8" NPT
Fig. 38 Dimensions RPI transmitter
Sensor output signals
Media types
Media temperature (operation)
Ambient air temperature
(operation)
Storage temperature
Humidity
System burst pressure
liquids, gasses and air
-22 to 212 °F [-30 to 100 °C]
-13 to 140 °F [-25 to 95 °C]
-67 to 158 °F [-55 to 70 °C]
0 to 95 % RH, non-condensing
870 psi [60 bar]
Electrical data (Only RPI without temperature sensor)
Power supply RPI
Output signals
Power consumption
Load impedance
12 to 30 VDC
4 to 20 mA
660 mW
max. 60 ˖ at 12.5 VDC
max. 100 ˖ at 13.3 VDC
m.ax 900 ˖ at 30 VDC
Electrical data (Only RPI with temperature sensor)
Power supply RPI + T
Output signals
Max. signal cable length
Power consumption
Load impedance
20 mA
16.6 to 30 VDC
0 to 10 VDC
98 ft [30 m]
450 mW
min. 10 k˖
4 mA
0
360 psi [25 bar]
TM04 9189 3610
Sensor materials
Enclosure class
Temperature cycling
Vibration (non-destructive)
Electromagnetic compatibility
0
32 °F [0 °C]
360 psi [25 bar]
212 °F [100 °C]
Fig. 40 Pressure and temperature response of RPI +T
TM04 91890 3610
10 V
14
Wetted materials
silicon-based MEMS sensor
EPDM or FKM rubber
stainless steel AISI 316 L
corrosion-resistant coating
EPDM or FKM rubber
stainless steel AISI 316 L
Environmental standards
Fig. 39 Pressure response of RPI 0-360 psi
0V
Measurement element
Packing material
Sensor housing
IP67
IEC 68-2-14
20 to 2000 Hz, 10G, 4h
EN 61326-1
3
Grundfos Direct Sensor™
DPI V.2 general data
Differential pressure transmitter, industrial (DPI) V.2
3. Differential pressure transmitter, industrial (DPI) V.2
Features
• Pressure range: 9 to 232 psi
• approved for potable water: WRAS (pending),
KTW (pending), ACS (pending)
• wide temperature range 32 to 212 °F [0 to 100 °C]
(DPI +T).
• 1/8" NPT-SW 27 capillary tube connection for P2
connection
• Max cable length (industry): 100 ft [30 meters]*
Differential pressure transmitter, industrial V.2
TM04 7866 2510
Benefits
•
•
•
•
•
Fig. 41 DPI transmitter
No moving parts
compatible with wet, aggressive media
cost-effective and robust construction
system solution with Grundfos pumps
Pressure and temperature measurement in one
transmitter.
Technical overview
Approvals
Grundfos Direct Sensorsറ, type DPI, are an industrial
differential pressure transmitter, designed to be
mounted directly in the pipe system (V.2). The DPI +T
version can also measure temperature in the range 32
to 212 °F [0 to 100 °C]. The DPI have a standard M12
connector.
•
•
•
•
•
WRAS
KTW
ACS
NSF 61
EU, US, and Canadian markets
Sensor chip
Steady state properties of silicon protects the sensor
chip against wear and tear. Lifelong nano-coating
protection enables for the first time, direct
measurement (wet and wet-wet) in a cost effective
packaging for aggressive media. The secret is a metalglass alloy coating, Silicoat® with an extreme
resistance to corrosion. Compared to traditional sensor
technologies which encapsulate the unprotected
measuring cell from the Media, Silicoat® ensures a
continuous protection of the Sensor Chip in aggressive
media (ph 2-ph 11) at temperatures up to 248 °F
[120 °C].
Applications
•
•
•
•
•
•
•
•
•
•
Water treatment and distribution
light chemical industry
water management
pool and water resort
heating
heat pump
air conditioning
cooling towers
condensing units
solar system.
15
3
Grundfos Direct Sensor™
Differential pressure transmitter, industrial (DPI) V.2
Type key
DPI
+T
0-6
G½" 020 E ,Set
Type
Temperature sensor:
+T = with temperature Sensor
Flow range [m3/h]
Thread size
Output signal:
020 = 4-20mA
O-ring material:
E = EPDM
F = FKM
Set = Complete pressure transmitter
Electrical connections
2
1
TM04 7156 1610
4
3
Fig. 42 Electrical connections
*
*
PIN
1
2
3
4
Wire color
Brown
Grey
Blue
Black
Output
4 - 20 mA
+
not used
-
not used
Output
2 x 0 - 10 V
+
Pressure
signal
-*
Temperature
signal
Common ground for both pressure and temperature signal.
Power supply (screened cable): SELV or PELV.
*Grundfos will not be liable for damage or wear to
products caused by abnormal operating conditions,
accident abuse, misuse unauthorized alteration or
repair, or if the product was not installed in
accordance with Grundfos' printed installation and
operating instructions. Splicing of the supplied cable
would void any warranty.
16
3
DPI 0-9 psi [0-0.6 bar]
Specifications
Differential pressure transmitter, industry V.2
Pressure
TM04 9239 3510
Measuring range
Accuracy (± 1˰), 32 to 176 °F
[0 to 80 °C]
Accuracy (± 1˰), -22 to 212 °F
[-30 to 100 °C]
Response time
Resolution
Fig. 43 DPI /DPI+T transmitter
Dimensions
Differential pressure transmitter, industrial (DPI) V.2
Grundfos Direct Sensor™
0 to 9 psi [0 to 0.6 bar]
± 2 % FS
± 2.5 % FS
< 100 ms (typical 50 ms)
1/1000 FS
Temperature (Only DPI with temperature sensor)
Range (relative)
Accuracy (± 1ı), 32 to 176 °F
[0 to 80 °C]
Accuracy (± 1ı), 32 to 212 °F
[0 to 100 °C]
Accuracy (± 1ı), -22 to 212 °F
[-30 to 100 °C]
Response time for sensor
electronics
Resolution
-22 to 212 °F [-30 to 100 °C]
± 1.8 °F [± 1 °C]
± 3.6 °F [± 2 °C]
± 5.4 °F [± 2.5 °C]
< 100ms (typical 50 ms)
0.18 °F [0.1 °C]
Media and environment
1/8" NPT
4.33 in.
TM04 4963 2612
0.25" flare
ISO 228 - G1/2
Fig. 44 Dimensions DPI/DPI+T
Sensor output signals
Media types
Media temperature (operation)
Ambient air temperature
(operation)
Storage temperature
Humidity
System burst pressure
liquids, gasses and air
-22 to 212 °F [-30 to 100 °C]
-13 to 140 °F [-25 to 95 °C]
-67 to 158 °F [-55 to 70 °C]
0 to 95 % RH, non-condensing
870 psi [60 bar]
Electrical data (Only DPI without temperature sensor)
Power supply DPI
Output signals
Power consumption
Load impedance
12 to 30 VDC
4 to 20 mA
660 mW
max. 60 ˖ at 12.5 VDC
max. 100 ˖ at 13.3 VDC
max. 900 ˖ at 30 VDC
Electrical data (Only DPI with temperature sensor)
Power supply DPI + T
Output signals
Max. signal cable length
Power consumption
Load impedance
20 mA
16.6 to 30 VDC
0 to 10 VDC
98 ft [30 m]
450 mW
min. 10 k˖
4 mA
0
9 psi [0.6 bar]
TM04 9189 3610
Sensor materials
Wetted materials
Enclosure class
Temperature cycling
Vibration (non-destructive)
Electromagnetic compatibility
360 psi [25 bar]
212 °F [100 °C]
IP67
IEC 68-2-14
20 to 2000 Hz, 10G, 4h
EN 61326-1
TM04 91890 3610
10 V
0
32 °F [0 °C]
silicon-based MEMS sensor
EPDM or FKM rubber
stainless steel AISI 316 L
corrosion-resistant coating
EPDM or FKM rubber
stainless steel AISI 316 L
Environmental standards
Fig. 45 Pressure response DPI
0V
Measurement element
Packing material
Sensor housing
Fig. 46 Pressure and temperature response DPI +T
17
3
Grundfos Direct Sensor™
Differential pressure transmitter, industrial (DPI) V.2
DPI 0-14.5 psi
Specifications
Differential pressure transmitter, industry V.2
Pressure
TM04 9239 3510
Measuring range
Accuracy (±1˰), 32 to 176 °F
[0 to 80 °C]
Accuracy (±1˰), -22 to 212 °F
[-30 to 100 °C]
Response time
Resolution
Fig. 47 DPI/DPI+T transmitter
Dimensions
0 to 14.5 psi [0 to 1.0 bar]
± 2 % FS
± 2.5 % FS
< 100 ms (typical 50 ms)
1/1000 FS
Temperature (Only DPI with temperature sensor)
Range (relative)
Accuracy (± 1ı) 32 to 176 °F
[0 to 80 °C]
Accuracy (± 1ı) 32 to 212 °F
[0 to 100 °C]
Accuracy (± 1ı) -22 to 212 °F
[-30 to 100 °C]
Response time for sensor
electronics
Resolution
-22 to 248 °F [-30 to 120 °C]
± 1.8 °F [± 1 °C]
± 3.6 °F [± 2 °C]
± 5.4 °F [± 2.5 °C]
< 100ms (typical 50 ms)
0.18 °F [0.1 °C]
Media and environment
Media types
Media temperature
(operation)
1/8" NPT
Media temperature (peak)
TM04 4963 2612
0.25" flare
4.33 in.
ISO 228 - G1/2
Ambient air temp. (operation)
Ambient air temp. (peak)
Storage temperature
Humidity
System burst pressure
liquids, gasses and air
-22 to 248 °F [-30 to 120 °C]
-22 to 266 °F [-30 to 130 °C],
non-freezing
-13 to 140 °F [-25 to 95 °C]
-67 to 158 °F [-55 to 70 °C]
-67 to 158 °F [-55 to 70 °C]
0 to 95 % RH, non-condensing
870 psi [60 bar]
Electrical data
(Only DPI without temperature sensor)
Fig. 48 Dimensions DPI/DPI+T
Sensor output signals
Power supply DPI
Output signals
Max. signal cable length
Power consumption
20 mA
Load impedance
11 to 30 VDC (± 5 %)
4 to 20 mA
98 ft [30 m]
22 mA
Max 100 ˖ at 11 VDC
Max 1000 ˖ at 30 VDC
4 mA
0
14.5 psi [1.0 bar]
TM04 9189 3610
Electrical data (Only DPI with temperature sensor)
Fig. 49 Pressure response DPI
Power supply DPI + T
Output signals
Max. signal cable length
Power consumption
Load impedance
Sensor materials
Measurement element
Packing material
Sensor housing
Wetted materials
0
32 °F [0 °C]
14.5 psi [1.0 bar]
212 °F [100 °C]
Fig. 50 Pressure and temperature response DPI+T
TM04 91890 3610
Enclosure class
Temperature cycling
Vibration (non-destructive)
Electromagnetic compatibility
18
silicon-based MEMS sensor
EPDM or FKM rubber
stainless steel AISI 316 L
corrosion-resistant coating
EPDM or FKM rubber
stainless steel AISI 316 L
Environmental standards
10 V
0V
14 to 30 VDC (± 5 %)
0 to 10 VDC
98 ft [30 m]
< 15 mA
Min. 10 k˖
IP55
IEC 68-2-14
20 to 2000 Hz, 10G, 4h
EN 61326-1
3
DPI 0-25 psi [0-1.6 bar]
Specifications
Differential pressure transmitter, industry V.2
Pressure
TM04 9239 3510
Measuring range
Accuracy (±1˰), 32 to 176 °F
[0 to 80 °C]
Accuracy (±1˰), -22 to 212 °F
[-30 to 100 °C]
Response time
Resolution
Fig. 51 DPI/DPI+T transmitter
Dimensions
Differential pressure transmitter, industrial (DPI) V.2
Grundfos Direct Sensor™
0 to 25 psi [0 to 1.6 bar]
± 2 % FS
± 2.5 % FS
< 100 ms (typical 50 ms)
1/1000 FS
Temperature (Only DPI with temperature sensor)
Range (relative)
Accuracy (± 1ı) 32 to 176 °F
[0 to 80 °C]
Accuracy (± 1ı) 32 to 212 °F
[0 to 100 °C]
Accuracy (± 1ı) -22 to 212 °F
[-30 to 100 °C]
Response time for sensor
electronics
Resolution
-22 to 248 °F [-30 to 120 °C]
± 1.8 °F [± 1 °C]
± 3.6 °F [± 2 °C]
± 5.4 °F [± 2.5 °C]
< 100ms (typical 50 ms)
0.18 °F [0.1 °C]
Media and environment
Media types
Media temperature
(operation)
1/8" NPT
Media temperature (peak)
TM04 4963 2612
0.25" flare
4.33 in.
ISO 228 - G1/2
Ambient air temp. (operation)
Ambient air temp. (peak)
Storage temperature
Humidity
System burst pressure
liquids, gasses and air
-22 to 248 °F [-30 to 120 °C]
-22 to 266 °F [-30 to 130 °C],
non-freezing
-13 to 140 °F [-25 to 95 °C]
-67 to 158 °F [-55 to 70 °C]
-67 to 158 °F [-55 to 70 °C]
0 to 95 % RH, non-condensing
870 psi [60 bar]
Electrical data (Only DPI without temperature sensor)
Fig. 52 Dimensions DPI/DPI+T
Power supply DPI
Output signals - cut off
Max. signal cable length
Power consumption
Sensor output signals
Load impedance
20 mA
11 to 30 VDC (± 5 %)
4 to 20 mA
98 ft [30 m]
22 mA
Max 100 ˖ at 11 VDC
Max 1000 ˖ at 30 VDC
4 mA
0
25 psi [1.6 bar]
TM04 9189 3610
Electrical data (Only DPI with temperature sensor)
Fig. 53 Pressure response DPI
Power supply DPI + T
Output signals
Max. signal cable length
Power consumption
Load impedance
14 to 30 VDC (± 5 %)
0 to 10 VDC
98 ft [30 m]
< 15 mA
Min. 10 k˖
Sensor materials
Measurement element
Packing material
Sensor housing
Wetted materials
silicon-based MEMS sensor
EPDM or FKM rubber
stainless steel AISI 316 L
corrosion-resistant coating
EPDM or FKM rubber
stainless steel AISI 316 L
Environmental standards
Enclosure class
Temperature cycling
Vibration (non-destructive)
Electromagnetic compatibility
0V
0
32 °F [0 °C]
25 psi [1.6 bar]
212 °F [100 °C]
IP55
IEC 68-2-14
20 to 2000 Hz, 10G, 4h
EN 61326-1
TM04 91890 3610
10 V
Fig. 54 Pressure and temperature response DPI+T
19
3
Grundfos Direct Sensor™
Differential pressure transmitter, industrial (DPI) V.2
DPI 0-40 psi [0-2.5 bar]
Specifications
Differential pressure transmitter, industry V.2
Pressure
TM04 9239 3510
Measuring range
Accuracy (±1˰), 32 to 176 °F
[0 to 80 °C]
Accuracy (±1˰), -22 to 212 °F
[-30 to 100 °C]
Response time
Resolution
Fig. 55 DPI/DPI+T transmitter
Dimensions
0 to 40 psi [0 to 2.5 bar]
± 2 % FS
± 2.5 % FS
< 100 ms (typical 50 ms)
1/1000 FS
Temperature (Only DPI with temperature sensor)
Range (relative)
Accuracy (± 1ı) 32 to 176 °F
[0 to 80 °C]
Accuracy (± 1ı) 32 to 212 °F
[0 to 100 °C]
Accuracy (± 1ı) -22 to 212 °F
[-30 to 100 °C]
Response time for sensor
electronics
Resolution
-22 to 248 °F [-30 to 120 °C]
± 1.8 °F [± 1 °C]
± 3.6 °F [± 2 °C]
± 5.4 °F [± 2.5 °C]
< 100ms (typical 50 ms)
0.18 °F [0.1 °C]
Media and environment
Media types
Media temperature
(operation)
1/8" NPT
Media temperature (peak)
TM04 4963 2612
0.25" flare
4.33 in.
ISO 228 - G1/2
Ambient air temp. (operation)
Ambient air temp. (peak)
Storage temperature
Humidity
System burst pressure
liquids, gasses and air
-22 to 248 °F [-30 to 120 °C]
-22 to 266 °F [-30 to 130 °C],
non-freezing
-13 to 140 °F [-25 to 95 °C]
-67 to 158 °F [-55 to 70 °C]
-67 to 158 °F [-55 to 70 °C]
0 to 95 % RH, non-condensing
870 psi [60 bar]
Electrical data (Only DPI without temperature sensor)
Fig. 56 Dimensions DPI/DPI+T
Power supply DPI
Output signals - cut off
Max. signal cable length
Power consumption
Sensor output signals
Load impedance
20 mA
11 to 30 VDC (± 5 %)
4 to 20 mA
98 ft [30 m]
22 mA
Max 100 ˖ at 11 VDC
Max 1000 ˖ at 30 VDC
4 mA
0
40. psi [2.5 bar]
TM04 9189 3610
Electrical data (Only DPI with temperature sensor)
Fig. 57 Pressure response DPI
Power supply DPI + T
Output signals
Max. signal cable length
Power consumption
Load impedance
14 to 30 VDC (± 5 %)
0 to 10 VDC
98 ft [30 m]
< 15 mA
Min. 10 k˖
Sensor materials
Measurement element
Packing material
Sensor housing
Wetted materials
silicon-based MEMS sensor
EPDM or FKM rubber
stainless steel AISI 316 L
corrosion-resistant coating
EPDM or FKM rubber
stainless steel AISI 316 L
Environmental standards
Enclosure class
Temperature cycling
Vibration (non-destructive)
Electromagnetic compatibility
0V
0
32 °F [0 °C]
40 psi [2.5 bar]
212 °F [100 °C]
Fig. 58 Pressure and temperature response DPI+T
20
TM04 91890 3610
10 V
IP55
IEC 68-2-14
20 to 2000 Hz, 10G, 4h
EN 61326-1
3
DPI 0-60 psi [0-4.0 bar]
Specifications
Differential pressure transmitter, industry V.2
Pressure
TM04 9239 3510
Measuring range
Accuracy (±1˰), 32 to 176 °F
[0 to 80 °C]
Accuracy (±1˰), -22 to 212 °F
[-30 to 100 °C]
Response time
Resolution
Fig. 59 DPI/DPI+T transmitter
Dimensions
Differential pressure transmitter, industrial (DPI) V.2
Grundfos Direct Sensor™
0 to 60 psi [0 to 4.0 bar]
± 2 % FS
± 2.5 % FS
< 100 ms (typical 50 ms)
1/1000 FS
Temperature (Only DPI with temperature sensor)
Range (relative)
Accuracy (± 1ı) 32 to 176 °F
[0 to 80 °C]
Accuracy (± 1ı) 32 to 212 °F
[0 to 100 °C]
Accuracy (± 1ı) -22 to 212 °F
[-30 to 100 °C]
Response time for sensor
electronics
Resolution
-22 to 248 °F [-30 to 120 °C]
± 1.8 °F [± 1 °C]
± 3.6 °F [± 2 °C]
± 5.4 °F [± 2.5 °C]
< 100ms (typical 50 ms)
0.18 °F [0.1 °C]
Media and environment
Media types
Media temperature
(operation)
1/8" NPT
Media temperature (peak)
TM04 4963 2612
0.25" flare
4.33 in.
ISO 228 - G1/2
Ambient air temp. (operation)
Ambient air temp. (peak)
Storage temperature
Humidity
System burst pressure
liquids, gasses and air
-22 to 248 °F [-30 to 120 °C]
-22 to 266 °F [-30 to 130 °C],
non-freezing
-13 to 140 °F [-25 to 95 °C]
-67 to 158 °F [-55 to 70 °C]
-67 to 158 °F [-55 to 70 °C]
0 to 95 % RH, non-condensing
870 psi [60 bar]
Electrical data (Only DPI without temperature sensor)
Fig. 60 Dimensions DPI/DPI+T
Power supply DPI
Output signals - cut off
Max. signal cable length
Power consumption
Sensor output signals
Load impedance
20 mA
11 to 30 VDC (± 5 %)
4 to 20 m - 21 mA
98 ft [30 m]
22 mA
Max 100 ˖ at 11 VDC
Max 1000 ˖ at 30 VDC
4 mA
0
60 psi [4.0 bar]
TM04 9189 3610
Electrical data (Only DPI with temperature sensor)
Fig. 61 Pressure response DPI
Power supply DPI + T
Output signals
Max. signal cable length
Power consumption
Load impedance
14 to 30 VDC (± 5 %)
0 to 10 VDC
98 ft [30 m]
< 15 mA
Min. 10 k˖
Sensor materials
Measurement element
Packing material
Sensor housing
Wetted materials
silicon-based MEMS sensor
EPDM or FKM rubber
stainless steel AISI 316 L
corrosion-resistant coating
EPDM or FKM rubber
stainless steel AISI 316 L
Environmental standards
Enclosure class
Temperature cycling
Vibration (non-destructive)
Electromagnetic compatibility
0V
0
32 °F [0 °C]
60 psi [4.0 bar]
212 °F [100 °C]
IP55
IEC 68-2-14
20 to 2000 Hz, 10G, 4h
EN 61326-1
TM04 91890 3610
10 V
Fig. 62 Pressure and temperature response DPI+T
21
3
Grundfos Direct Sensor™
Differential pressure transmitter, industrial (DPI) V.2
DPI 0-90 psi [0-6.0 bar]
Specifications
Differential pressure transmitter, industry V.2
Pressure
TM04 9239 3510
Measuring range
Accuracy (±1˰), 32 to 176 °F
[0 to 80 °C]
Accuracy (±1˰), -22 to 212 °F
[-30 to 100 °C]
Response time
Resolution
Fig. 63 DPI/DPI+T transmitter
Dimensions
0 to 90psi [0 to 6.0 bar]
± 2 % FS
± 2.5 % FS
< 100 ms (typical 50 ms)
1/1000 FS
Temperature (Only DPI with temperature sensor)
Range (relative)
Accuracy (± 1ı) 32 to 176 °F
[0 to 80 °C]
Accuracy (± 1ı) 32 to 212 °F
[0 to 100 °C]
Accuracy (± 1ı) -22 to 212 °F
[-30 to 100 °C]
Response time for sensor
electronics
Resolution
-22 to 248 °F [-30 to 120 °C]
± 1.8 °F [± 1 °C]
± 3.6 °F [± 2 °C]
± 5.4 °F [± 2.5 °C]
< 100ms (typical 50 ms)
0.18 °F [0.1 °C]
Media and environment
Media types
Media temperature
(operation)
1/8" NPT
Media temperature (peak)
TM04 4963 2612
0.25" flare
4.33 in.
ISO 228 - G1/2
Ambient air temp. (operation)
Ambient air temp. (peak)
Storage temperature
Humidity
System burst pressure
liquids, gasses and air
-22 to 248 °F [-30 to 120 °C]
-22 to 266 °F [-30 to 130 °C],
non-freezing
-13 to 140 °F [-25 to 95 °C]
-67 to 158 °F [-55 to 70 °C]
-67 to 158 °F [-55 to 70 °C]
0 to 95 % RH, non-condensing
870 psi [60 bar]
Electrical data (Only DPI without temperature sensor)
Fig. 64 Dimensions DPI/DPI+T
Power supply DPI
Output signals
Max. signal cable length
Power consumption
Sensor output signals
Load impedance
20 mA
11 to 30 VDC (± 5 %)
4 to 20 mA
98 ft [30 m]
22 mA
Max 100 ˖ at 11 VDC
Max 1000 ˖ at 30 VDC
4 mA
0
90 psi [6.0 bar]
TM04 9189 3610
Electrical data (Only DPI with temperature sensor)
Fig. 65 Pressure response DPI
Power supply DPI + T
Output signals
Max. signal cable length
Power consumption
Load impedance
14 to 30 VDC (± 5 %)
0 to 10 VDC
98 ft [30 m]
< 15 mA
Min. 10 k˖
Sensor materials
Measurement element
Packing material
Sensor housing
Wetted materials
silicon-based MEMS sensor
EPDM or FKM rubber
stainless steel AISI 316 L
corrosion-resistant coating
EPDM or FKM rubber
stainless steel AISI 316 L
Environmental standards
Enclosure class
Temperature cycling
Vibration (non-destructive)
Electromagnetic compatibility
0V
0
32 °F [0 °C]
90 psi [6.0 bar]
212 °F [100 °C]
Fig. 66 Pressure and temperature response DPI+T
22
TM04 91890 3610
10 V
IP55
IEC 68-2-14
20 to 2000 Hz, 10G, 4h
EN 61326-1
3
DPI 0-145 psi [0-10.0 bar]
Specifications
Differential pressure transmitter, industry V.2
Pressure
TM04 9239 3510
Measuring range
Accuracy (±1˰), 32 to 176 °F
[0 to 80 °C]
Accuracy (±1˰), -22 to 212 °F
[-30 to 100 °C]
Response time
Resolution
Fig. 67 DPI/DPI+T transmitter
Dimensions
Differential pressure transmitter, industrial (DPI) V.2
Grundfos Direct Sensor™
0 to 145 psi [0 to 10.0 bar]
± 2 % FS
± 2.5 % FS
< 100 ms (typical 50 ms)
1/1000 FS
Temperature (Only DPI with temperature sensor)
Range (relative)
Accuracy (± 1ı) 32 to 176 °F
[0 to 80 °C]
Accuracy (± 1ı) 32 to 212 °F
[0 to 100 °C]
Accuracy (± 1ı) -22 to 212 °F
[-30 to 100 °C]
Response time for sensor
electronics
Resolution
-22 to 248 °F [-30 to 120 °C]
± 1.8 °F [± 1 °C]
± 3.6 °F [± 2 °C]
± 5.4 °F [± 2.5 °C]
< 100ms (typical 50 ms)
0.18 °F [0.1 °C]
Media and environment
Media types
Media temperature
(operation)
1/8" NPT
Media temperature (peak)
TM04 4963 2612
0.25" flare
4.33 in.
ISO 228 - G1/2
Ambient air temp. (operation)
Ambient air temp. (peak)
Storage temperature
Humidity
System burst pressure
liquids, gasses and air
-22 to 248 °F [-30 to 120 °C]
-22 to 266 °F [-30 to 130 °C],
non-freezing
-13 to 140 °F [-25 to 95 °C]
-67 to 158 °F [-55 to 70 °C]
-67 to 158 °F [-55 to 70 °C]
0 to 95 % RH, non-condensing
870 psi [60 bar]
Electrical data (Only DPI without temperature sensor)
Fig. 68 Dimensions DPI/DPI+T
Power supply DPI
Output signals - cut off
Max. signal cable length
Power consumption
Sensor output signals
Load impedance
20 mA
11 to 30 VDC (± 5 %)
4 to 20 mA
98 ft [30 m]
22 mA
Max 100 ˖ at 11 VDC
Max 1000 ˖ at 30 VDC
4 mA
0
145 psi [10.0 bar]
TM04 9189 3610
Electrical data (Only DPI with temperature sensor)
Fig. 69 Pressure response DPI
Power supply DPI + T
Output signals
Max. signal cable length
Power consumption
Load impedance
14 to 30 VDC (± 5 %)
0 to 10 VDC
98 ft [30 m]
< 15 mA
Min. 10 k˖
Sensor materials
Measurement element
Packing material
Sensor housing
Wetted materials
silicon-based MEMS sensor
EPDM or FKM rubber
stainless steel AISI 316 L
corrosion-resistant coating
EPDM or FKM rubber
stainless steel AISI 316 L
Environmental standards
Enclosure class
Temperature cycling
Vibration (non-destructive)
Electromagnetic compatibility
0V
0
32 °F [0 °C]
145 psi [10 bar]
212 °F [100 °C]
IP55
IEC 68-2-14
20 to 2000 Hz, 10G, 4h
EN 61326-1
TM04 91890 3610
10 V
Fig. 70 Pressure and temperature response DPI+T
23
3
Grundfos Direct Sensor™
Differential pressure transmitter, industrial (DPI) V.2
DPI 0-232 psi [0-16.0 bar]
Specifications
Differential pressure transmitter, industry V.2
Pressure
TM04 9239 3510
Measuring range
Accuracy (±1˰), 32 to 176 °F
[0 to 80 °C]
Accuracy (±1˰), -22 to 212 °F
[-30 to 100 °C]
Response time
Resolution
Fig. 71 DPI/DPI+T transmitter
Dimensions
0 to 232 psi [0 to 16.0 bar]
± 2.5 % FS
± 3 % FS
< 100 ms (typical 50 ms)
1/1000 FS
Temperature (Only DPI with temperature sensor)
Range (relative)
Accuracy (± 1ı) 32 to 176 °F
[0 to 80 °C]
Accuracy (± 1ı) 32 to 212 °F
[0 to 100 °C]
Accuracy (± 1ı) -22 to 212 °F
[-30 to 100 °C]
Response time for sensor
electronics
Resolution
-22 to 248 °F [-30 to 120 °C]
± 1.8 °F [± 1 °C]
± 3.6 °F [± 2 °C]
± 5.4 °F [± 2.5 °C]
< 100ms (typical 50 ms)
0.18 °F [0.1 °C]
Media and environment
Media types
Media temperature
(operation)
1/8" NPT
Media temperature (peak)
TM04 4963 2612
0.25" flare
4.33 in.
ISO 228 - G1/2
Ambient air temp. (operation)
Ambient air temp. (peak)
Storage temperature
Humidity
System burst pressure
liquids, gasses and air
-22 to 248 °F [-30 to 120 °C]
-22 to 266 °F [-30 to 130 °C],
non-freezing
-13 to 140 °F [-25 to 95 °C]
-67 to 158 °F [-55 to 70 °C]
-67 to 158 °F [-55 to 70 °C]
0 to 95 % RH, non-condensing
870 psi [60 bar]
Electrical data (Only DPI without temperature sensor)
Fig. 72 Dimensions DPI/DPI+T
Power supply DPI
Output signals - cut off
Max. signal cable length
Power consumption
Sensor output signals
Load impedance
20 mA
11 to 30 VDC (± 5 %)
4 to 20 mA
98 ft [30 m]
22 mA
Max 100 ˖ at 11 VDC
Max 1000 ˖ at 30 VDC
4 mA
0
232psi [16 bar]
TM04 9189 3610
Electrical data (Only DPI with temperature sensor)
Fig. 73 Pressure response DPI
Power supply DPI + T
Output signals
Max. signal cable length
Power consumption
Load impedance
14 to 30 VDC (± 5 %)
0 to 10 VDC
98 ft [30 m]
< 15 mA
Min. 10 k˖
Sensor materials
Measurement element
Packing material
Sensor housing
Wetted materials
silicon-based MEMS sensor
EPDM or FKM rubber
stainless steel AISI 316 L
corrosion-resistant coating
EPDM or FKM rubber
stainless steel AISI 316 L
Environmental standards
Enclosure class
Temperature cycling
Vibration (non-destructive)
Electromagnetic compatibility
0V
0
32 °F [0 °C]
232 psi [16 bar]
212 °F [100 °C]
Fig. 74 Pressure and temperature response DPI+T
24
TM04 91890 3610
10 V
IP55
IEC 68-2-14
20 to 2000 Hz, 10G, 4h
EN 61326-1
4
Grundfos Direct Sensor™
DPI general data
Differential pressure transmitter, industrial (DPI)
4. Differential pressure transmitter, industrial (DPI)
Benefits
• Compatible with wet, aggressive media
• accurate, linearized output signal
• cost-effective and robust design.
TM04 4738 0509
Differential pressure transmitter, Industrial
Fig. 75 DPI transmitter
Technical overview
Grundfos Direct Sensorsറ, type DPI, are a series of
differential pressure transmitters for industry. The DPI
sensors are compatible with wet, aggressive media
and are available for differential pressure ranges from
0-9 psi to 0-145 psi.
Sensor chip
Steady state properties of silicon protects the sensor
chip against wear and tear. Lifelong nano-coating
protection enables for the first time, direct
measurement (wet and wet-wet) in a cost effective
packaging for aggressive media. The secret is a metalglass alloy coating, Silicoat® with an extreme
resistance to corrosion. Compared to traditional sensor
technologies which encapsulate the unprotected
measuring cell from the Media, Silicoat® ensures a
continuous protection of the Sensor Chip in aggressive
media (ph 2-ph 11) at temperatures up to 248 °F
[120 °C].
Applications
•
•
•
•
•
•
•
•
Pumps and pumping control systems
filters (monitoring)
cooling and temperature control systems
water treatment systems
heat pump
boiler control systems
renewable energy systems
heat exchanger efficiency (monitoring of fouling).
Features
•
•
•
•
•
•
•
Differential Pressure ranges: 9 to 145 psi
designed for harsh environments
analog output signal
compact and well proven design
MEMS sensing technology
approved for the EU, US and Canadian markets.
Max cable length (industry): 100 ft [30 meters]*
25
4
Grundfos Direct Sensor™
Differential pressure transmitter, industrial (DPI)
Type key
The sensor is labelled with a type designation.
96561232
- XX
- XXX XXXXX
Product number
Version
Production year and week
Consecutive number
Electrical connections
1
2
3
4
TM04 9191 3610
A
PE
Fig. 76 Electrical connections
Pin configuration
color
1
Test conductor (can be cut off during mounting).
Do not connect this conductor to the voltage supply.
2
Signal conductor
Green
3
GND (earth conductor)
Yellow
4
12 to 30 V supply voltage
Brown
White
*Grundfos will not be liable for damage or wear to
products caused by abnormal operating conditions,
accident abuse, misuse unauthorized alteration or
repair, or if the product was not installed in accordance
with Grundfos' printed installation and operating
instructions. Splicing of the supplied cable would void
any warranty.
26
4
DPI 0-9 psi [0-0.6 bar]
Specifications
Differential pressure transmitter, industry
Pressure
TM04 5034 2409
Measuring range (differential)
Accuracy (IEC 61298-2)
Response time
Static Pressure P1
Static Pressure P2
Max system pressure
Fig. 77 DPI transmitter
Dimension
Differential pressure transmitter, industrial (DPI)
Grundfos Direct Sensor™
0 to 9 psi [0 to 0.6 bar]
3.5 % FS
< 0.5 s
232 psi [16.0 bar]
145 psi [10.0 bar]
232 psi [16.0 bar]
Media and environment
Media
Liquids, gases and air
Media temperature (operation)
14 to 158 °F [-18 to 106 °C]
Media temperature (peak)
up to 176 °F [80 °C]
Ambient air temperature
-40 to 158 °F [-40 to 106 °C]
Ambient air temperature
-67 to 194 °F [-55 to 90 °C]
(peak)
Humidity
0 to 95 % (relative), non-condensing
System burst pressure
360 psi [25.0 bar]
Electrical data
Power supply
Output signals
Load impedance
Sensor materials
SW14
3.03 in. [77 mm]
P2
P1
1.77 in. [45 mm]
0.24 in. [6 mm]
0.55 in. [14 mm]
TM03 2059 1612
1/8" flare
12 to 30 VDC
4 to 20 mA
24 V max. 500 k˖
16 V max. 200 k˖
12 V max. 100 k˖
Fig. 78 Dimensions DPI transmitter
Output signals
Sensing element
Seal
Housing
Wetted materials
Silicon-based MEMS sensor
FKM rubber
AISI 303 stainless steel
FKM and PPS
Environmental standards
Enclosure class
Temperature cycling
Vibration (non-destructive)
Immunity
Emission
Weight
IP55
IEC 68-2-14
20 to 2000 Hz, 10G, 4h
EN 61000-6-2
EN 61000-6-3
1.2 lbs
4 mA
0
9 psi [0.6 bar]
TM04 9189 3610
20 mA
Fig. 79 Differential pressure response
27
4
Grundfos Direct Sensor™
Differential pressure transmitter, industrial (DPI)
DPI 0-14.5 psi [0-1.0 bar]
Specifications
Differential pressure transmitter, industry
Pressure
TM04 5034 2409
Measuring range (differential)
Accuracy (IEC 61298-2)
Response time
Static Pressure P1
Static Pressure P2
Max system pressure
Fig. 80 DPI transmitter
Dimension
0 to 14.5 psi [0 to 1.0 bar]
2 % FS
< 0.5 s
232 psi [16.0 bar]
145 psi [10.0 bar]
232 psi [16.0 bar]
Media and environment
Media
Liquids, gasses and air
Media temperature (operation)
14 to 158 °F [-18 to 106 °C]
Media temperature (peak)
up to 176 °F [80 °C]
Ambient air temperature
-40 to 158 °F [-40 to 106 °C]
Ambient air temperature
-67 to 194 °F [-55 to 90 °C]
(peak)
Humidity
0 to 95 % (relative), non-condensing
System burst pressure
360 psi [25.0 bar]
Electrical data
Power supply
Output signals
Load impedance
Sensor materials
SW14
3.03 in. [77 mm]
P2
P1
1.77 in. [45 mm]
0.24 in. [6 mm]
0.55 in. [14 mm]
TM03 2059 1612
1/8" flare
Fig. 81 Dimensions DPI transmitter
Output signals
4 mA
14.5 psi [1.0 bar]
Fig. 82 Differential pressure response
28
TM04 9189 3610
20 mA
0
12-30 VDC
4-20 mA
24 V max. 500 k˖
16 V max. 200 k˖
12 V max. 100 k˖
Sensing element
Seal
Housing
Wetted materials
Silicon-based MEMS sensor
FKM rubber
AISI 303 stainless steel
FKM and PPS
Environmental standards
Enclosure class
Temperature cycling
Vibration (non-destructive)
Immunity
Emission
Weight
IP55
IEC 68-2-14
20 to 2000 Hz, 10G, 4h
EN 61000-6-2
EN 61000-6-3
1.2 lbs
4
DPI 0-17.4 psi [0-1.2 bar]
Specifications
Differential pressure transmitter, industry
Pressure
TM04 5034 2409
Measuring range (differential)
Accuracy (IEC 61298-2)
Response time
Static Pressure P1
Static Pressure P2
Max system pressure
Fig. 83 DPI transmitter
Dimension
Differential pressure transmitter, industrial (DPI)
Grundfos Direct Sensor™
0 to 17.4 psi [0 to 1.2 bar]
2 % FS
< 0.5 s
232 psi [16.0 bar]
145 psi [10.0 bar]
232 psi [16.0 bar]
Media and environment
Media
Liquids, gasses and air
Media temperature (operation)
14 to 158 °F [-18 to 106 °C]
Media temperature (peak)
up to 176 °F [80 °C]
Ambient air temperature
-40 to 158 °F [-40 to 106 °C]
Ambient air temperature
-67 to 194 °F [-55 to 90 °C]
(peak)
Humidity
0 to 95 % (relative), non-condensing
System burst pressure
360 psi [25.0 bar]
Electrical data
Power supply
Output signals
Load impedance
Sensor materials
SW14
3.03 in. [77 mm]
P2
P1
1.77 in. [45 mm]
0.24 in. [6 mm]
0.55 in. [14 mm]
TM03 2059 1612
1/8" flare
12-30 VDC
4-20 mA
24 V max. 500 k˖
16 V max. 200 k˖
12 V max. 100 k˖
Fig. 84 Dimensions DPI transmitter
Output signals
Sensing element
Seal
Housing
Wetted materials
Silicon-based MEMS sensor
FKM rubber
AISI 303 stainless steel
FKM and PPS
Environmental standards
Enclosure class
Temperature cycling
Vibration (non-destructive)
Immunity
Emission
Weight
IP55
IEC 68-2-14
20 to 2000 Hz, 10G, 4h
EN 61000-6-2
EN 61000-6-3
1.2 lbs
4 mA
0
17.4 psi [1.2 bar]
TM04 9189 3610
20 mA
Fig. 85 Differential pressure response
29
4
Grundfos Direct Sensor™
Differential pressure transmitter, industrial (DPI)
DPI 0-25 psi [0-1.6 bar]
Specifications
Differential pressure transmitter, industry
Pressure
TM04 5034 2409
Measuring range (differential)
Accuracy (IEC 61298-2)
Response time
Static Pressure P1
Static Pressure P2
Max system pressure
Fig. 86 DPI transmitter
Dimension
0 to 25 psi [0 to 1.6 bar]
2 % FS
< 0.5 s
232 psi [16.0 bar]
145 psi [10.0 bar]
232 psi [16.0 bar]
Media and environment
Media
Liquids, gasses and air
Media temperature (operation)
14 to 158 °F [-18 to 106 °C]
Media temperature (peak)
up to 176 °F [80 °C]
Ambient air temperature
-40 to 158 °F [-40 to 106 °C]
Ambient air temperature
-67 to 194 °F [-55 to 90 °C]
(peak)
Humidity
0 to 95 % (relative), non-condensing
System burst pressure
360 psi [25.0 bar]
Electrical data
Power supply
Output signals
Load impedance
Sensor materials
SW14
3.03 in. [77 mm]
P2
P1
1.77 in. [45 mm]
0.24 in. [6 mm]
0.55 in. [14 mm]
TM03 2059 1612
1/8" flare
Fig. 87 Dimensions DPI transmitter
Output signals
4 mA
25 psi [1.6 bar]
Fig. 88 Differential pressure response
30
TM04 9189 3610
20 mA
0
12-30 VDC
4-20 mA
24 V max. 500 k˖
16 V max. 200 k˖
12 V max. 100 k˖
Sensing element
Seal
Housing
Wetted materials
Silicon-based MEMS sensor
FKM rubber
AISI 303 stainless steel
FKM and PPS
Environmental standards
Enclosure class
Temperature cycling
Vibration (non-destructive)
Immunity
Emission
Weight
IP55
IEC 68-2-14
20 to 2000 Hz, 10G, 4h
EN 61000-6-2
EN 61000-6-3
1.2 lbs
4
DPI 0-40 psi [0-2.5 bar]
Specifications
Differential pressure transmitter, industry
Pressure
TM04 5034 2409
Measuring range (differential)
Accuracy (IEC 61298-2)
Response time
Static Pressure P1
Static Pressure P2
Max system pressure
Fig. 89 DPI transmitter
Dimension
Differential pressure transmitter, industrial (DPI)
Grundfos Direct Sensor™
0 to 40 psi [0 to 2.5 bar]
2 % FS
< 0.5 s
232 psi [16.0 bar]
145 psi [10.0 bar]
232 psi [16.0 bar]
Media and environment
Media
Liquids, gasses and air
Media temperature (operation)
14 to 158 °F [-18 to 106 °C]
Media temperature (peak)
up to 176 °F [80 °C]
Ambient air temperature
-40 to 158 °F [-40 to 106 °C]
Ambient air temperature
-67 to 194 °F [-55 to 90 °C]
(peak)
Humidity
0 to 95 % (relative), non-condensing
System burst pressure
360 psi [25.0 bar]
Electrical data
Power supply
Output signals
Load impedance
Sensor materials
SW14
3.03 in. [77 mm]
P2
P1
1.77 in. [45 mm]
0.24 in. [6 mm]
0.55 in. [14 mm]
TM03 2059 1612
1/8" flare
12-30 VDC
4-20 mA
24 V max. 500 k˖
16 V max. 200 k˖
12 V max. 100 k˖
Fig. 90 Dimensions DPI transmitter
Output signals
Sensing element
Seal
Housing
Wetted materials
Silicon-based MEMS sensor
FKM rubber
AISI 303 stainless steel
FKM and PPS
Environmental standards
Enclosure class
Temperature cycling
Vibration (non-destructive)
Immunity
Emission
Weight
IP55
IEC 68-2-14
20 to 2000 Hz, 10G, 4h
EN 61000-6-2
EN 61000-6-3
1.2 lbs
4 mA
0
40 psi [2.5 bar]
TM04 9189 3610
20 mA
Fig. 91 Differential pressure response
31
4
Grundfos Direct Sensor™
Differential pressure transmitter, industrial (DPI)
DPI 0-60 psi [0-4.0 bar]
Specifications
Differential pressure transmitter, industry
Pressure
TM04 5034 2409
Measuring range (differential)
Accuracy (IEC 61298-2)
Response time
Static Pressure P1
Static Pressure P2
Max system pressure
Fig. 92 DPI transmitter 0 to 60 psi
Dimension
0 to 60 psi [0 to 4.0 bar]
2 % FS
< 0.5 s
232 psi [16.0 bar]
145 psi [10.0 bar]
232 psi [16.0 bar]
Media and environment
Media
Liquids, gasses and air
Media temperature (operation)
14 to 158 °F [-18 to 106 °C]
Media temperature (peak)
up to 176 °F [80 °C]
Ambient air temperature
-40 to 158 °F [-40 to 106 °C]
Ambient air temperature
-67 to 194 °F [-55 to 90 °C]
(peak)
Humidity
0 to 95 % (relative), non-condensing
System burst pressure
360 psi [25.0 bar]
Electrical data
Power supply
Output signals
Load impedance
Sensor materials
SW14
3.03 in. [77 mm]
P2
P1
1.77 in. [45 mm]
0.24 in. [6 mm]
0.55 in. [14 mm]
TM03 2059 1612
1/8" flare
Fig. 93 Dimensions DPI transmitter
Output signals
4 mA
60 psi [4.0 bar]
Fig. 94 Differential pressure response
32
TM04 9189 3610
20 mA
0
12-30 VDC
4-20 mA
24 V max. 500 k˖
16 V max. 200 k˖
12 V max. 100 k˖
Sensing element
Seal
Housing
Wetted materials
Silicon-based MEMS sensor
FKM rubber
AISI 303 stainless steel
FKM and PPS
Environmental standards
Enclosure class
Temperature cycling
Vibration (non-destructive)
Immunity
Emission
Weight
IP55
IEC 68-2-14
20 to 2000 Hz, 10G, 4h
EN 61000-6-2
EN 61000-6-3
1.2 lbs
4
DPI 0-90 psi [0-6.0 bar]
Specifications
Differential pressure transmitter, industry
Pressure
TM04 5034 2409
Measuring range (differential)
Accuracy (IEC 61298-2)
Response time
Static Pressure P1
Static Pressure P2
Max system pressure
Fig. 95 DPI transmitter 0 to 90 psi [0 to 6.0 bar]
Dimension
Differential pressure transmitter, industrial (DPI)
Grundfos Direct Sensor™
0 to 90 psi [0 to 6.0 bar]
2 % FS
< 0.5 s
232 psi [16.0 bar]
145 psi [10.0 bar]
232 psi [16.0 bar]
Media and environment
Media
Liquids, gasses and air
Media temperature (operation)
14 to 158 °F [-18 to 106 °C]
Media temperature (peak)
up to 176 °F [80 °C]
Ambient air temperature
-40 to 158 °F [-40 to 106 °C]
Ambient air temperature
-67 to 194 °F [-55 to 90 °C]
(peak)
Humidity
0 to 95 % (relative), non-condensing
System burst pressure
360 psi [25.0 bar]
Electrical data
Power supply
Output signals
Load impedance
Sensor materials
SW14
3.03 in. [77 mm]
P2
P1
1.77 in. [45 mm]
0.24 in. [6 mm]
0.55 in. [14 mm]
TM03 2059 1612
1/8" flare
12-30 VDC
4-20 mA
24 V max. 500 k˖
16 V max. 200 k˖
12 V max. 100 k˖
Fig. 96 Dimensions DPI transmitter
Output signals
Sensing element
Seal
Housing
Wetted materials
Silicon-based MEMS sensor
FKM rubber
AISI 303 stainless steel
FKM and PPS
Environmental standards
Enclosure class
Temperature cycling
Vibration (non-destructive)
Immunity
Emission
Weight
IP55
IEC 68-2-14
20 to 2000 Hz, 10G, 4h
EN 61000-6-2
EN 61000-6-3
1.2 lbs
4 mA
0
90 psi [6.0 bar]
TM04 9189 3610
20 mA
Fig. 97 Differential pressure response
33
4
Grundfos Direct Sensor™
Differential pressure transmitter, industrial (DPI)
DPI 0-145 psi [0-10.0 bar]
Specifications
Differential pressure transmitter, industry
Pressure
TM04 5034 2409
Measuring range (differential)
Accuracy (IEC 61298-2)
Response time
Static Pressure P1
Static Pressure P2
Max system pressure
Fig. 98 DPI transmitter 0 to 145 psi
Dimension
0 to 145 psi [0 to 10 bar]
2 % FS
< 0.5 s
232 psi [16.0 bar]
145 psi [10.0 bar]
232 psi [16.0 bar]
Media and environment
Media
Liquids, gasses and air
Media temperature (operation)
14 to 158 °F [-18 to 106 °C]
Media temperature (peak)
up to 176 °F [80 °C]
Ambient air temperature
-40 to 158 °F [-40 to 106 °C]
Ambient air temperature
-67 to 194 °F [-55 to 90 °C]
(peak)
Humidity
0 to 95 % (relative), non-condensing
System burst pressure
360 psi [25.0 bar]
Electrical data
Power supply
Output signals
Load impedance
Sensor materials
SW14
3.03 in. [77 mm]
P2
P1
1.77 in. [45 mm]
0.24 in. [6 mm]
0.55 in. [14 mm]
TM03 2059 1612
1/8" flare
Fig. 99 Dimensions DPI transmitter
Output signals
4 mA
145 psi [10 bar]
Fig. 100 Differential pressure response
34
TM04 9189 3610
20 mA
0
12-30 VDC
4-20 mA
24 V max. 500 k˖
16 V max. 200 k˖
12 V max. 100 k˖
Sensing element
Seal
Housing
Wetted materials
Silicon-based MEMS sensor
FKM rubber
AISI 303 stainless steel
FKM and PPS
Environmental standards
Enclosure class
Temperature cycling
Vibration (non-destructive)
Immunity
Emission
Weight
IP55
IEC 68-2-14
20 to 2000 Hz, 10G, 4h
EN 61000-6-2
EN 61000-6-3
1.2 lbs
5
Grundfos Direct Sensor™
RPS general data
Relative pressure sensor standard (RPS)
5. Relative pressure sensor standard (RPS)
Features
TM03 8138 0607
Relative pressure sensor, standard
Fig. 101RPS sensor
Technical overview
Grundfos Direct Sensors™, type RPS, is a series of
combined pressure and temperature sensors (two-inone) designed for high-volume production. The RPS
sensors are fully compatible with wet, aggressive
media and are available for pressure ranges from 08.7 to 0-145 psi (relative pressure).
• Pressure ranges: 8.7 to 145 psi.
• voltage output (ratio metric, ideal for use with micro
controller)
• compact and robust mechanical design
• approved for potable water: WRAS, KTW, W270,
ACS.
• Max cable length (standard): 10 ft [3 meters]*
• Approved for EU, US and Canadian markets.
Benefits
• Pressure and temperature sensor in one package
(two-in-one sensor)
• compatible with wet, aggressive media
• accurate, linearised and temperature-compensated
pressure sensor
• quick temperature response (direct media contact).
Sensor chip
Steady state properties of silicon protects the sensor
chip against wear and tear. Lifelong nano-coating
protection enables for the first time, direct
measurement (wet and wet-wet) in a cost effective
packaging for aggressive media. The secret is a metalglass alloy coating, Silicoat® with an extreme
resistance to corrosion. Compared to traditional sensor
technologies which encapsulate the unprotected
measuring cell from the Media, Silicoat® ensures a
continuous protection of the Sensor Chip in aggressive
media (ph 2-ph 11) at temperatures up to 248 °F
[120 °C].
Applications
• Domestic hot-water system efficiency
• water level in central heating system
• dry-running protection in solar systems and gas
boilers
• monitoring of pressure and temperature.
• solar system
• heat pumps
35
5
Grundfos Direct Sensor™
Relative pressure sensor standard (RPS)
Type key
The sensor is labelled with a type designation.
96XXXXXX
- XX
- XXX XXXXX
Product number
Revision
Production year and week
Consecutive number
Electrical connections
1
2
3
4
V
TM05 2253 4711
V
Pipe system
PE
Fig. 102Electrical connections
Pin configuration
Colour
Yellow
1
Temperature signal (0.5 to 3.5 V relative to pin 3)
2
Pressure signal (0.5 to 3.5 V relative to pin 3)
White
3
GND (0 V)
Green
4
Voltage supply (+5 VDC), PELV
Brown
Power supply requirements
• 5 VDC
• separated from hazardous live circuitry by double or
reinforced insulation
• power limitation:150 VA; current limitation: 8 A.
Options
A
TM03 8139 0607
B
Fig. 103Sensor options
Pos.
Description
A
1/2'' nipple, stainless steel (316L) or 3/8" composite
B
simple connector
*Grundfos will not be liable for damage or wear to products caused by
abnormal operating conditions, accident abuse, misuse unauthorized
alteration or repair, or if the product was not installed in accordance
with Grundfos' printed installation and operating instructions. Splicing
of the supplied cable would void any warranty.
36
5
Specifications
Relative pressure transmitter, standard 0-9 psi
Pressure
TM05 2254 4711
RPS 0-9 psi [0-0.6 bar]
Fig. 104RPS sensor, 0-9 psi
Dimensions In. [mm]
1.57 in. [39.9 mm]
Measuring range
Accuracy (± 1˰), 77 to 176 °F
[25 to 80 °C]
Accuracy (± 1˰), 32 to 212 °F
[0 to 100 °C]
Response time (63.3 % at flow
velocity >2 m/s)
Resolution
Media
Media temperature (operation)
0.41 in. [10.3 mm]
0.59 in. [14.9 mm]
TM03 8136 1612
1.84 in. [46.8
± 2% FS
± 3% FS
< 0.5 s
.07 psi [0.005 bar]
Temperature
Media temperature (peak)
0.18 in. [4.5
0 to 9 psi [0 to 0.6 bar]
32 to 212 °F [0 to 100 °C]
± 1.8 °F [± 1 °C]
± 3.6 °F [± 2 °C]
< 1.5 s
1 °F [0.56 °C]
Media and environment
0.79 in. [20 mm]
0.79 in. [20 mm]
Measuring range (relative)
Accuracy (± 1˰), 77 to 176 °F
[25 to 80 °C]
Accuracy (± 1˰), 32 to 212 °F
[0 to 100 °C]
Response time
Resolution
Relative pressure sensor standard (RPS)
Grundfos Direct Sensor™
Fig. 105 Dimensions RPS sensor
Output signals
Ambient air temperature
(operation)
Ambient air temperature
(peak)
Humidity
System burst pressure
Liquids
32 to 212 °F [0 to 100 °C]
-13 to 248 °F [-25 to 120 °C],
non-freezing
-13 to 140 °F [-25 to 95 °C]
-67 to 194 °F [-55 to 90 °C]
0 to 95 % (relative), non-condensing
> 435.1 psi [30 bar]
Electrical data
Power supply (ground req)
Output signals
Pressure signal
Temperature signal
Power consumption
Load impedance
5 VDC (±5 %).
Ratiometric
0.5 to 3.5 V
0.5 to 3.5 V
< 50 mW
> 10 k˖
Sensor materials
Sensor
Seal (sensor to housing)
Housing
Wetted materials
Silicon-based MEMS sensor
EPDM rubber
Composites (PPS)
Corrosion-resistant coating EPDM,
PPS
TM03 8141 1612
Environmental standards
Fig. 106Pressure response
Enclosure class
Temperature cycling
Vibration (non-destructive)
Electromagnetic compatibility
IP44
IEC 68-2-14
20 to 2000 Hz, 10G, 4h
EN 61326-1
Dimensions
Sensor
1.85 x 1.57 x 0.79 in.
[47 X 40 X 20 mm]
TM03 8149 1612
[V]
Fig. 107Temperature response
37
5
Grundfos Direct Sensor™
Specifications
Relative pressure transmitter, standard 0-14.5 psi
Pressure
TM05 2254 4711
Relative pressure sensor standard (RPS)
RPS 0-14.5 psi [0-1.0 bar]
Fig. 108RPS sensor, 0-14.5 psi
Dimensions In. [mm]
1.57 in. [39.9 mm]
0.41 in. [10.3 mm]
0.59 in. [14.9 mm]
TM03 8136 1612
1.84 in. [46.8
0.18 in. [4.5
0 to 14.5 psi [0 to 1.0 bar]
±2% FS
±3% FS
< 0.5 s
.07 psi [0.005 bar]
Temperature
Measuring range
Accuracy (±1˰),77 to 176 °F
[25 to 80 °C]
Accuracy (±1˰), 32 to 212 °F
[0 to 100 °C]
Response time (63.3 % at flow
velocity > 2 m/s)
Resolution
32 to 212 °F [0 to 100 °C]
± 1.8 °F [± 1 °C]
± 3.6 °F [± 2 °C]
< 1.5 s
1 °F [0.56 °C]
Media and environment
0.79 in. [20 mm]
0.79 in. [20 mm]
Measuring range (relative)
Accuracy (±1˰), 77 to 176 °F
[25 to 80 °C]
Accuracy (±1˰), 32 to 212 °F
[0 to 100 °C]
Response time
Resolution
Fig. 109Dimensions RPS sensor
Output signals
Media
The sensor is compatible with liquids
Media temperature (operation)
32 to 212 °F [0 to 100 °C]
-13 to 248 °F [-25 to 120 °C],
Media temperature (peak)
non-freezing
Ambient air temperature
-13 to 140 °F [-25 to 95 °C]
(operation)
Ambient air temperature
-67 to 194 °F [-55 to 90 °C]
(peak)
Humidity
0 to 95 % (relative), non-condensing
System burst pressure
> 435.1 psi [30 bar]
Electrical data
Power supply (ground req)
Output signals
Pressure signal
Temperature signal
Power consumption
Load impedance
5 VDC (±5 %).
Ratiometric
0.5 to 3.5 V
0.5 to 3.5 V
< 50 mW
> 10 k˖
Sensor materials
Sensor
Seal (sensor to housing)
Housing
Wetted materials
Silicon-based MEMS sensor
EPDM rubber
Composites (PPS)
Corrosion-res coating, EPDM, PPS
TM03 8142 1612
Environmental standards
TM03 8149 1612
[V]
38
IP44 (Non over molded IP20)
IEC 68-2-14
20 to 2000 Hz, 10G, 4h
EN 61326-1
Dimensions
Sensor
Fig. 110Pressure response
Fig. 111 Temperature response
Enclosure class
Temperature cycling
Vibration (non-destructive)
Electromagnetic compatibility
1.85 x 1.57 x 0.79 in.
[47 X 40 X 20 mm]
5
Specifications
Relative pressure transmitter, standard 0-25 psi
Pressure
TM05 2254 4711
RPS 0-25 psi [0-1.6 bar]
Fig. 112RPS sensor, 0-25 psi
Dimensions In. [mm]
Measuring range (relative)
Accuracy (±1˰), 77 to 176 °F
[25 to 80 °C]
Accuracy (±1˰), 32 to 212 °F [0
to 100 °C]
Response time
Resolution
Relative pressure sensor standard (RPS)
Grundfos Direct Sensor™
0 to 25 psi [0 to 1.6 bar]
±1.5 % FS
±2.5 % FS
< 0.5 s
.07 psi [0.005 bar]
Temperature
Measuring range
Accuracy (±1˰), 77 to 176 °F
[25 to 80 °C]
Accuracy (±1˰), 32 to 212 °F [0
to 100 °C]
Response time (63.3 % at flow
velocity > 2 m/s)
Resolution
32 to 212 °F [0 to 100 °C]
± 1.8 °F [± 1 °C]
± 3.6 °F [± 2 °C]
< 1.5 s
1 °F [0.56 °C]
Media and environment
0.79 in. [20 mm]
1.57 in. [39.9 mm]
Media temperature (operation)
0.79 in. [20 mm]
Media temperature (peak)
0.18 in. [4.5
0.41 in. [10.3 mm]
0.59 in. [14.9 mm]
TM03 8136 1612
1.84 in. [46.8
Media
Fig. 113 Dimensions RPS sensor
Output signals
Ambient air temperature
(operation)
Ambient air temperature (peak)
Relative humidity
System burst pressure
The sensor is compatible with
liquids
32 to 212 °F [0 to 100 °C]
-13 to 248 °F [-25 to 120 °C],
non-freezing
-13 to 140 °F [-25 to 95 °C]
-67 to 194 °F [-55 to 90 °C]
0 to 95 %, non-condensing
> 435.1 psi [30 bar]
Electrical interface
Power supply (ground req)
Output signals
Pressure signal
Temperature signal
Power consumption
Load impedance
5 VDC (±5 %).
Ratiometric
0.5 to 3.5 V
0.5 to 3.5 V
< 50 mW
> 10 k˖
Sensor materials
Sensor
Seal (sensor to housing)
Housing
Wetted materials
Silicon-based MEMS sensor
EPDM rubber
Composites (PPS)
Corrosion-res coating, EPDM, PPS
TM03 8143 1612
Environmental standards
Enclosure class
Temperature cycling
Vibration (non-destructive)
Electromagnetic compatibility
Dimensions
Sensor
Fig. 114Pressure response
IP44
IEC 68-2-14
20 to 2000 Hz, 10G, 4h
EN 61326-1
1.85 x 1.57 x 0.79 in.
[47 X 40 X 20 mm]
TM03 8149 1612
[V]
Fig. 115 Temperature response
39
5
Grundfos Direct Sensor™
Specifications
Relative pressure transmitter, standard 0-40 psi
Pressure
TM05 2254 4711
Relative pressure sensor standard (RPS)
RPS 0-40 psi [0-2.5 bar]
Fig. 116RPS sensor, 0-40 psi
Dimensions In. [mm]
0.41 in. [10.3 mm]
0.59 in. [14.9 mm]
TM03 8136 1612
1.84 in. [46.8
0.18 in. [4.5
0 to 40 psi [0 to 2.5 bar]
±1.5 % FS
±2 % FS
< 0.5 s
0.3 psi [0.02 bar]
Temperature
Measuring range
Accuracy (±1˰), 77 to 176 °F
[25 to 80 °C]
Accuracy (±1˰), 32 to 212 °F
[0 to 100 °C]
Response time
(63.3 % at flow velocity >
2 m/s)
Resolution
32 to 212 °F [0 to 100 °C]
± 1.8 °F [± 1 °C]
± 37 °F [± 2.8 °C]
< 1.5 s
1 °F [0.56 °C]
Media and environment
1.57 in. [39.9 mm]
0.79 in. [20 mm]
0.79 in. [20 mm]
Measuring range (relative)
Accuracy (±1˰), 77 to 176 °F
[25 to 80 °C]
Accuracy (±1˰), 32 to 212 °F
[0 to 100 °C]
Response time
Resolution
Fig. 117Dimensions RPS sensor
Output signals
Media
The sensor is compatible with liquids
Media temperature (operating)
32 to 212 °F [0 to 100 °C]
-13 to 248 °F [-25 to 120 °C],
Media temperature (peak)
non-freezing
Ambient air temperature
-13 to 140 °F [-25 to 95 °C]
(operating)
Ambient air temperature
-67 to 194 °F [-55 to 90 °C]
(peak)
Humidity
0 to 95 % (relative), non-condensing
System burst pressure
> 435.1 psi [30 bar]
Electrical data
Power supply
Output signals
Pressure signal
Temperature signal
Power consumption
Load impedance
5 VDC (±5 %). Grounding of the
sensor supply is recommended.
Ratiometric
0.5 to 3.5 V
0.5 to 3.5 V
< 50 mW
> 10 k˖
Sensor materials
Sensor
Seal (sensor to housing)
Housing
Wetted materials
Silicon-based MEMS sensor
EPDM rubber
Composites (PPS)
Corrosion-res coating, EPDM, PPS
TM03 8144 1612
Environmental standards
Fig. 118Pressure response
TM03 8149 0607
40
IP44
IEC 68-2-14
20 to 2000 Hz, 10G, 4h
EN61326-1
Dimensions
Sensor
[V]
Fig. 119Temperature response
Enclosure class
Temperature cycling
Vibration (non-destructive)
Electromagnetic compatibility
1.85 x 1.57 x 0.79 in.
[47 X 40 X 20 mm]
5
RPS 0-60 psi [0-4.0 bar]
Specifications
Relative pressure transmitter, standard 0-60 psi
Pressure
TM05 2254 4711
Measuring range (relative)
Accuracy (±1˰), 77 to 176 °F
[25 to 80 °C]
Accuracy (±1˰), 32 to 212 °F [0
to 100 °C]
Response time
Resolution
Fig. 120RPS sensor, 0-60 psi
Dimensions In. [mm]
Relative pressure sensor standard (RPS)
Grundfos Direct Sensor™
0 to 60 psi [0 to 4.0 bar]
±2 % FS
±2.5 % FS
< 0.5 s
0.3 psi [0.02 bar]
Temperature
Measuring range
Accuracy (±1˰), 77 to 176 °F
[25 to 80 °C]
Accuracy (±1˰), 32 to 212 °F [0
to 100 °C]
Response time (63.3 % at flow
velocity > 2 m/s)
Resolution
32 to 212 °F [0 to 100 °C]
± 1.8 °F [± 1 °C]
± 3.6 °F [± 2 °C]
< 1.5 s
1 °F [0.56 °C]
Media and environment
1.57 in. [39.9 mm]
Media
Media temperature (operation)
0.79 in. [20 mm]
Media temperature (peak)
The sensor is compatible with
liquids
32 to 212 °F [0 to 100 °C]
-13 to 248 °F [-25 to 120 °C],
non-freezing
Ambient air temperature
-13 to 140 °F [-25 to 95 °C]
(operation)
Ambient air temperature (peak)
-67 to 194 °F [-55 to 90 °C]
Humidity
0 to 95 % (relative), non-condensing
System burst pressure
> 435.1 psi [30 bar]
0.18 in. [4.5
0.41 in. [10.3 mm]
0.59 in. [14.9 mm]
TM03 8136 1612
1.84 in. [46.8
0.79 in. [20 mm]
Fig. 121Dimensions RPS sensor
Output signals
Electrical data
Power supply
Output signals
Pressure signal
Temperature signal
Power consumption
Load impedance
5 VDC (±5 %). Grounding of the
sensor supply is recommended.
Ratiometric
0.5 to 3.5 V
0.5 to 3.5 V
< 50 mW
> 10 k˖
Sensor materials
Sensor
Seal (sensor to housing)
Housing
Wetted materials
Silicon-based MEMS sensor
EPDM rubber
Composites (PPS)
Corrosion-res coating, EPDM, PPS
TM03 8145 1612
Environmental standards
Enclosure class
Temperature cycling
Vibration (non-destructive)
Electromagnetic compatibility
Dimensions
Sensor
Fig. 122Pressure response
IP44
IEC 68-2-14
20 to 2000 Hz, 10G, 4h
EN 61326-1
1.85 x 1.57 x 0.79 in.
[47 X 40 X 20 mm]
TM03 8149 1612
[V]
Fig. 123Temperature response
41
5
Grundfos Direct Sensor™
Specifications
Relative pressure transmitter, standard 0-90 psi
Pressure
TM05 2254 4711
Relative pressure sensor standard (RPS)
RPS 0-90 psi [0-6.0 bar]
Fig. 124RPS sensor, 0-90 psi
Dimensions In. [mm]
1.57 in. [39.9 mm]
0.41 in. [10.3 mm]
0.59 in. [14.9 mm]
TM03 8136 1612
1.84 in. [46.8
0.18 in. [4.5
0 to 90 psi [0 to 6.0 bar]
±2% FS
±2.5% FS
< 0.5 s
0.3 psi [0.02 bar]
Temperature
Measuring range
Accuracy (±1˰), 77 to 176 °F
[25 to 80 °C]
Accuracy (±1˰), 32 to 212 °F
[0 to 100 °C]
Response time (63.3 % at flow
velocity > 2 m/s)
Resolution
32 to 212 °F [0 to 100 °C]
± 1.8 °F [± 1 °C]
± 37 °F [± 2.8 °C]
< 1.5 s
1 °F [0.56 °C]
Media and environment
0.79 in. [20 mm]
0.79 in. [20 mm]
Measuring range (relative)
Accuracy (±1˰), 77 to 176 °F
[25 to 80 °C]
Accuracy (±1˰), 32 to 212 °F
[0 to 100 °C]
Response time
Resolution
Fig. 125Dimensions RPS sensor
Output signals
Media
The sensor is compatible with liquids
Media temperature (operation)
32 to 212 °F [0 to 100 °C]
-13 to 248 °F [-25 to 120 °C], nonMedia temperature (peak)
freezing
Ambient air temperature
-13 to 140 °F [-25 to 95 °C]
(operation)
Ambient air temperature
-67 to 194 °F [-55 to 90 °C]
(peak)
Humidity
0 to 95 % (relative), non-condensing
System burst pressure
> 435.1 psi [30 bar]
Electrical data
Power supply
Output signals
Pressure signal
Temperature signal
Power consumption
Load impedance
5 VDC (±5 %). Grounding of the
sensor supply is recommended.
Ratiometric
0.5 to 3.5 V
0.5 to 3.5 V
< 50 mW
> 10 k˖
Sensor materials
Sensor
Seal (sensor to housing)
Housing
Wetted materials
Silicon-based MEMS sensor
EPDM rubber
Composites (PPS)
Corrosion-resistant coating EPDM,
PPS
TM03 8146 1612
Environmental standards
Enclosure class
Temperature cycling
Vibration (non-destructive)
Electromagnetic compatibility
IP44
IEC 68-2-14
20 to 2000 Hz, 10G, 4h
EN 61326-1
Dimensions
Fig. 126Pressure response
Sensor
TM03 8149 0607
[V]
Fig. 127Temperature response
42
1.85 x 1.57 x 0.79 in.
[47 X 40 X 20 mm]
5
Specifications
Relative pressure transmitter, standard 0-145 psi
Pressure
TM05 2254 4711
RPS 0-145 psi [0-10.0 bar]
Fig. 128RPS sensor, 0-145 psi
Dimensions In. [mm]
0.41 in. [10.3 mm]
0.59 in. [14.9 mm]
TM03 8136 1612
1.84 in. [46.8
0.18 in. [4.5
0 to 145 psi [0 - 10.0 bar]
±2 % FS
±2.5 % FS
< 1.0 s / 1.5 s
0.3 psi [0.02 bar]
Temperature
Measuring range
Accuracy (±1˰), 77 to 176 °F
[25 to 80 °C]
Accuracy (±1˰), 32 to 212 °F
[0 to 100 °C]
Response time
(63.3 % at flow velocity > 2 m/
s)
Resolution
32 to 212 °F [0 to 100 °C]
± 1.8 °F [± 1 °C]
± 37 °F [± 2.8 °C]
< 1.5 s
1 °F [0.56 °C]
Media and environment
1.57 in. [39.9 mm]
0.79 in. [20 mm]
0.79 in. [20 mm]
Measuring range (relative)
Accuracy (±1˰), 77 to 176 °F
[25 to 80 °C]
Accuracy (±1˰), 32 to 212 °F
[0 to 100 °C]
Response time
Resolution
Relative pressure sensor standard (RPS)
Grundfos Direct Sensor™
Fig. 129Dimensions RPS sensor
Output signals
Media
The sensor is compatible with liquids
Media temperature (operation)
32 to 212 °F [0 to 100 °C]
-13 to 248 °F [-25 to 120 °C],
Media temperature (peak)
non-freezing
Ambient air temperature
-13 to 140 °F [-25 to 95 °C]
(operation)
Ambient air temperature
-67 to 194 °F [-55 to 90 °C]
(peak)
Humidity
0 to 95 % (relative), non-condensing
System burst pressure
> 435.1 psi [30 bar]
Electrical data
Power supply
Output signals
Pressure signal
Temperature signal
Power consumption
Load impedance
5 VDC (±5 %). Grounding of the
sensor supply is recommended.
Ratiometric
0.5 to 3.5 V
0.5 to 3.5 V
< 50 mW
> 10 k˖
Sensor materials
Sensor element
Seal (sensor to housing)
Housing
TM05 4947 2712
Wetted materials
Silicon-based MEMS sensor
EPDM rubber
Composites (PPS)
Corrosion-resistant coating EPDM,
PPS
Environmental standards
Enclosure class
Temperature cycling
Vibration (non-destructive)
Electromagnetic compatibility
IP44
IEC 68-2-14
20-2000 Hz, 10G, 4h
EN 61326-1
Physical properties
Fig. 130Pressure response
Sensor dimensions
TM03 8149 1612
[V]
1.85 x 1.57 x 0.79 in.
[47 X 40 X 20 mm]
Fig. 131Temperature response
43
6
Grundfos Direct Sensor™
Differential pressure sensor, standard (DPS)
6. Differential pressure sensor, standard (DPS)
DPS general data
Features
TM04 4457 1309
•
•
•
•
Fig. 132DPS sensor
Technical overview
Grundfos Direct Sensorsറ, type DPS, is a series of
combined differential-pressure and temperature
sensors (two-in-one). The DPS sensors are fully
compatible with wet, aggressive media.
Sensor chip
Steady state properties of silicon protects the sensor
chip against wear and tear. Lifelong nano-coating
protection enables for the first time, direct
measurement (wet and wet-wet) in a cost effective
packaging for aggressive media. The secret is a metalglass alloy coating, Silicoat® with an extreme
resistance to corrosion. Compared to traditional sensor
technologies which encapsulate the unprotected
measuring cell from the Media, Silicoat® ensures a
continuous protection of the Sensor Chip in aggressive
media (ph 2-ph 11) at temperatures up to 248 °F
[120 °C].
Applications
•
•
•
•
•
•
•
•
44
Pump and pump control systems
water treatment systems
filters (monitoring)
floor heating
heat pump
valve-controlled systems
cooling and temperature control systems
building management systems.
•
•
•
•
Differential pressure ranges: 9 to 90 psi
high burst pressure
compact and robust mechanical design
voltage output (ratiometric, ideal for use with micro
controller)
approved for potable water: WRAS, KTW, ACS.
designed for harsh environments.
Max cable length (standard): 10 ft [3 meters]*
Approved for EU, US and Canadian markets
Benefits
• Differential-pressure and temperature sensor in one
package (two-in-one sensor)
• compatible with wet, aggressive media
• accurate, linearized and temperature-compensated
differential-pressure transmitter
• quick temperature response (direct media contact).
6
Grundfos Direct Sensor™
96XXXXXX
- XX
Differential pressure sensor, standard (DPS)
Type key
- XXXX XXXXX
Product number
Version
Production year and week
Consecutive number
Electrical connections
1
2
3
4
V
TM05 2253 4711
V
Pipe system
PE
Fig. 133Electrical connections
Pin configuration
color
1
Temperature signal (0.5 to 4.5 V relative to pin 3)
2
Pressure signal (0.5 to 4.5 V relative to pin 3)
Yellow
White
3
GND (0 V)
Green
4
Voltage supply (+5 VDC), PELV
Brown
Power supply requirements
• 5 VDC
• separated from hazardous live circuitry by double or
reinforced insulation
• power limitation: 150 VA; current limitation: 8 A.
Options
Housing for DPS 316L
Fitting 0.24 in. [6 mm]
Fitting 0.31 in. [8 mm]
AISI 316
Fitting 0.24 in. [6 mm]
Fitting 0.31 in. [8 mm]
Wall bracket
Flow by pipe test set for sensor
Sensor over moulded
Tube connection
Compression fitting
*Grundfos will not be liable for damage or wear to products caused by
abnormal operating conditions, accident abuse, misuse unauthorized
alteration or repair, or if the product was not installed in accordance
with Grundfos' printed installation and operating instructions. Splicing
of the supplied cable would void any warranty.
45
6
Grundfos Direct Sensor™
Specifications
Differential pressure sensor, standard 0-9 psi
series 100
Pressure
TM04 4457 1309
Differential pressure sensor, standard (DPS)
DPS 0-9 psi [0-0.6 bar]
Fig. 134DPS sensor
Dimension in. [mm]
0.44 in. [11.2 mm]
0.57 in. [14.6 mm]
0.50 in. [12.6 mm]
TM04 4456 1612
mm]
0.06 in. [1.5
0.44 in. [11.2 mm]
Fig. 135 Dimensional sketches of sensing element
P1 is the high-pressure side
± 2 % FS
± 3.0 % FS
< 0.5 s
0.09 psi/psi [6 mbar/bar]
0.02 psi [1.2 mbar]
Temperature
Measuring range
Accuracy (± 1˰), 77 to 176 °F
[25 to 80 °C]
Accuracy (± 1˰), 32 to 212 °F
[0 to 100 °C]
Response time, sensing
element to output change
Resolution
Media
Media temperature
(operation)
Media temperature (peak)
Ambient air temp. (operation)
Ambient air temp. (peak)
Humidity (relative)
Application pressure P1
1.57 in. [40 mm]
1.30 in. [32.9 mm]
TM04 4455 1612
1/8-27 NPT
1.30 in. [33 mm]
1.38 in. [35 mm]
1.22 in. [31 mm]
1/8-27 NPT
0 to 9 psi [0 to 0.6 bar]
32 to 212 °F [0 to 100 °C]
± 1.8 °F [± 1 °C]
± 3.6 °F [± 2 °C]
< 1.0 s
± 0.36 °F [± 0.2 °C]
Media and Environment
[1.18 mm ]
R 0.05 in.
0.80 in. [20.2 mm]
1.89 in. [47.9 mm}
0.80 in. [20.3 mm]
0.08 in. [2 mm]
0.09 in. [2.3 mm]
0.79 in. [20 mm]
Measuring range
(differential)
Accuracy (± 1˰), 77 to 176 °F
[25 to 80 °C]
Accuracy (± 1˰), 32 to 212 °F
[0 to 100 °C]
Response time
System pressure deviation
Resolution
Differential pressure P1 to P2
Burst pressure P 1
Burst pressure P 2
Output signals
32 to 212 °F [0 to 100 °C]
-13 to 248 °F [-25 to 120 °C],
media must not freeze
-13 to 140 °F [-25 to 95 °C]
-67 to 194 °F [-55 to 90 °C]
0 to 95 %, non-condensing
Max. 232 psi at 158 °F
[Max. 16 bar at 70 °C]
Max. 174 psi at 212 °F
[Max. 12 bar at 100 °C]
Max. |145| psi [Max. |10| bar]
Max. 435.1 psi [Max. 30 bar]
Max. 145 psi [Max. 10 bar]
Electrical data
Power supply
Output signals
Pressure signal
Temperature signal
Power consumption
Load impedance
Fig. 136Isometric view of housing for DPS
Liquids, air, and gases
5 VDC (± 5 %). Grounding
of the sensor supply is required.
Ratiometric
0.5 to 4.5 V
0.5 to 4.5 V
< 50 mW
> 10 k˖
TM04 4449 1612
Sensor materials
Fig. 137Differential pressure response
Sensing element
Sealing Cap
Housing
Wetted materials
Silicon-based MEMS sensor
EPDM rubber
Composite (PPS)
Corrosion-res coating, EPDM, PPS
Environmental standards
Enclosure class
Temperature cycling
Vibration (non-destructive)
Electromagnetic compatibility
IP44
IEC 68-2-14
20 to 2000 Hz, 10G, 4h
EN 61326-1
Dimensions
5.0
Sensing element
4.5
4.0
3.5
3.0
2.5
1.5
1.0
0.5
0.0
Fig. 138Temperature response
46
TM04 4458 1612
2.0
1.85 x 1.57 x 0.79 in.
[47 X 40 X 20 mm]
6
Specifications
Differential pressure sensor, standard 0-14.5 psi
series 100
Pressure
TM04 4457 1309
DPS 0-14.5 psi [0-1.0 bar]
Fig. 139DPS sensor
Dimension in. [mm]
TM04 4456 1612
1.89 in. [47.9
R 0.0 5 in.
0.80 in. [20.2
0.80 in. [20.3
0.08 in. [2
0.09 in. [2.3
0.79 in. [20
[1.18
0.06 in. [1.5
0.44 in. [11.2
0.44 in. [11.2
0.57 in. [14.6
0.50 in. [12.6
1.30 in. [32.9 mm]
Fig. 141Isometric view of housing for DPS
Media
Media temperature
(operation)
Differential pressure P1 to P2
Burst pressure P 1
Burst pressure P 2
±3.0 % FS
< 0.5 s
0.09 psi/psi [6 mbar/bar]
0.02 psi [1.2 mbar]
32 to 212 °F [0 to 100 °C]
± 1.8 °F [± 1 °C]
± 3.6 °F [± 2 °C]
< 1.0 s
± 0.36 °F [± 0.2 °C]
Liquids, air, and gases
32 to 212 °F [0 to 100 °C]
-13 to 248 °F [-25 to 120 °C],
media must not freeze
-13 to 140 °F [-25 to 95 °C]
-67 to 194 °F [-55 to 90 °C]
0 to 95 %, non-condensing
Max. 232 psi at 158 °F
[Max. 16 bar at 70 °C]
Max. 174 psi at 212 °F
[Max. 12 bar at 100 °C]
Max. |145| psi [Max. |10| bar]
Max. 435.1 psi [Max. 30 bar]
Max. 145 psi [Max. 10 bar]
Electrical data
Power supply
Output signals
Pressure signal
Temperature signal
Power consumption
Load impedance
Output signals
±2 % FS
Media and Environment
Application pressure P1
TM04 4455 1612
1/8-27 NPT
1.30 in. [33 mm]
1.22 in. [31 mm]
1/8-27 NPT
Measuring range
Accuracy (±1˰), 77 to 176 °F
[25 to 80 °C]
Accuracy (±1˰), 32 to 212 °F
[0 to 100 °C]
Response time, sensing
element to output change
Resolution
Ambient air temp. (operation)
Ambient air temp. (peak)
Humidity (relative)
1.38 in. [35 mm]
0 to 14.5 psi [0 to 1.0 bar]
Temperature
Media temperature (peak)
Fig. 140 Dimensional sketches of sensing element
P1 is the high-pressure side
1.57 in. [40 mm]
Measuring range
(differential)
Accuracy (±1˰), 77 to 176 °F
[25 to 80 °C]
Accuracy (±1˰), 32 to 212 °F
[0 to 100 °C]
Response time
System pressure deviation
Resolution
Differential pressure sensor, standard (DPS)
Grundfos Direct Sensor™
5 VDC (±5 %).
Ratiometric
0.5 to 4.5 V
0.5 to 4.5 V
< 50 mW
> 10 k˖
Sensor materials
TM04 4450 1612
Fig. 142Differential pressure response
5.0
Sensing element
Sealing Cap
Housing
Wetted materials
Silicon-based MEMS sensor
EPDM rubber
Composite (PPS)
Corrosion-res. coating, EPDM, PPS
Environmental standards
Enclosure class
Temperature cycling
Vibration (non-destructive)
Electromagnetic compatibility
IP44 (over moulded)
IEC 68-2-14
20 to 2000 Hz, 10G, 4h
EN 61326-1
Dimensions
4.5
4.0
Sensing element
3.5
1.85 x 1.57 x 0.79 in.
[47 X 40 X 20 mm]
3.0
2.0
1.5
1.0
0.5
0.0
TM04 4458 1612
2.5
Fig. 143Temperature response
47
6
Grundfos Direct Sensor™
Specifications
Differential pressure sensor, standard 0-25 psi
series 100
Pressure
TM04 4457 1309
Differential pressure sensor, standard (DPS)
DPS 0-25 psi [0-1.6 bar]
Fig. 144DPS sensor
Dimension in. [mm]
TM04 4456 1612
1.89 in. [47.9 mm}
0.80 in. [20.2
0.80 in. [20.3
0.08 in. [2 mm]
0.09 in. [2.3
0.79 in. [20 mm]
[1.18
R 0.05 in.
5 mm]
0.06 in. [1.
0.44 in. [11.2
0.44 in. [11.2
0.57 in. [14.6
0.50 in. [12.6
Fig. 145Dimensional sketches of sensing element
P1 is the high-pressure side
1.57 in. [40 mm]
Measuring range
Accuracy (±1˰), 77 to 176 °F
[25 to 80 °C]
Accuracy (±1˰), 32 to 212 °F
[0 to 100 °C]
Response time, sensing
element to output change
Resolution
±2 % FS
±2.5 % FS
< 0.5 s
0.09 psi/psi [6 mbar/bar]
0.02 psi [1.6 mbar]
32 to 212 °F [0 to 100 °C]
± 1.8 °F [± 1 °C]
± 3.6 °F [± 2 °C]
< 1.0 s
± 0.36 °F [± 0.2 °C]
Media and environment
Media
Media temperature
(operation)
Ambient air temp. (operation)
Ambient air temp. (peak)
Humidity (relative)
TM04 4455 1612
1.30 in. [32.9 mm]
1.30 in. [33 mm]
1/8-27 NPT
0 to 25 psi [0 to 1.6 bar]
Temperature
Media temperature (peak)
1.38 in. [35 mm]
1.22 in. [31 mm]
1/8-27 NPT
Measuring range
(differential)
Accuracy (±1˰), 77 to 176 °F
[25 to 80 °C]
Accuracy (±1˰), 32 to 212 °F
[0 to 100 °C]
Response time
System pressure deviation
Resolution
Application pressure P1
Differential pressure P1 to P2
Burst pressure P 1
Burst pressure P 2
Liquids, air, and gases
32 to 212 °F [0 to 100 °C]
-13 to 248 °F [-25 to 120 °C],
media must not freeze
-13 to 140 °F [-25 to 95 °C]
-67 to 194 °F [-55 to 90 °C]
0 to 95 %, non-condensing
Max. 232 psi at 158 °F
[Max. 16 bar at 70 °C]
Max. 174 psi at 212 °F
[Max. 12 bar at 100 °C]
Max. |145| psi [Max. 10 bar]
Max. 435.1 psi [Max. 30 bar]
Max. 145 psi [Max. 10 bar]
Electrical data
Fig. 146Isometric view of housing for DPS
Power supply
Output signals
Pressure signal
Temperature signal
Power consumption
Load impedance
Output signals
5 VDC (±5 %).
Ratiometric
0.5 to 4.5 V
0.5 to 4.5 V
< 50 mW
> 10 k˖
TM04 4451 1612
Sensor materials
5.0
4.5
3.5
Sensing element
3.0
0.5
0.0
Fig. 148Temperature response
48
TM04 4458 1612
2.5
1.0
IP44
IEC 68-2-14
20 to 2000 Hz, 10G, 4h
EN 61326-1
Dimensions
4.0
1.5
Silicon-based MEMS sensor
EPDM rubber
Composite (PPS)
Corrosion-res coating, EPDM, PPS
Environmental standards
Enclosure class
Temperature cycling
Vibration (non-destructive)
Electromagnetic compatibility
Fig. 147Differential pressure response
2.0
Sensing element
Sealing Cap
Housing
Wetted materials
1.85 x 1.57 x 0.79 in.
[47 X 40 X 20 mm]
6
Specifications
Differential pressure sensor, standard 0 to 40 psi
series 100
Pressure
TM04 4457 1309
DPS 0-40 psi [0-2.5 bar]
Dimension in. [mm]
TM04 4456 1612
1.89 in. [47.9 mm}
[1.18
R 0.05 in.
0.80 in. [20.2
0.80 in. [20.3
0.08 in. [2 mm]
0.09 in. [2.3
0.79 in. [20 mm]
5 mm]
0.06 in. [1.
0.44 in. [11.2
0.44 in. [11.2
0.57 in. [14.6
0.50 in. [12.6
1.57 in. [40 mm]
Ambient air temp. (operation)
Ambient air temp. (peak)
Humidity (relative)
Application pressure P1
TM04 4455 1612
1.30 in. [33 mm]
1.22 in. [31 mm]
1.30 in. [32.9 mm]
Differential pressure P1 to P2
Burst pressure P 1
Burst pressure P 2
Output signals
±2.5 % FS
< 0.5 s
0.09 psi/psi [6 mbar/bar]
0.04 psi [2.5 mbar]
32 to 212 °F [0 to 100 °C]
± 1.8 °F [± 1 °C]
± 3.6 °F [± 2 °C]
< 1.0 s
± 0.36 °F [± 0.2 °C]
Liquids, air, and gases
32 to 212 °F [0 to 100 °C]
-13 to 248 °F [-25 to 120 °C],
media must not freeze
-13 to 140 °F [-25 to 65 °C]
-67 to 194 °F [-55 to 90 °C]
0 to 95 %, non-condensing
Max. 232 psi at 158 °F
[Max. 16 bar at 70 °C]
Max. 174 psi at 212 °F
[Max. 12 bar at 100 °C]
Max. |145| psi [Max. |10| bar]
Max. 435.1 psi [Max. 30 bar]
Max. 145 psi [Max. 10 bar]
Electrical data
Power supply
Output signals
Pressure signal
Temperature signal
Power consumption
Load impedance
Fig. 151Isometric view of housing for DPS
5 VDC (±5 %)
Ratiometric
0.5 to 4.5 V
0.5 to 4.5 V
< 50 mW
> 10 k˖
Sensor materials
TM04 4452 1612
Media
Media temperature
(operation)
1.38 in. [35 mm]
1/8-27 NPT
±2 % FS
Media and environment
Media temperature (peak)
Fig. 150Dimensional sketches of sensing element
P1 is the high-pressure side
0 to 40 psi [0 to 2.5 bar]
Temperature
Measuring range
Accuracy (± 1˰), 77 to 176 °F
[25 to 80 °C]
Accuracy (± 1˰), 32 to 212 °F
[0 to 100 °C]
Response time, sensing
element to output change
Resolution
Fig. 149DPS sensor
1/8-27 NPT
Measuring range
(differential)
Accuracy (±1˰), 77 to 176 °F
[25 to 80 °C]
Accuracy (±1˰), 32 to 212 °F
[0 to 100 °C]
Response time
System pressure deviation
Resolution
Differential pressure sensor, standard (DPS)
Grundfos Direct Sensor™
Fig. 152Differential pressure response
Sensing element
Sealing Cap
Housing
Wetted materials
Silicon-based MEMS sensor
EPDM rubber
Composite (PPS)
Corrosion-res coating, EPDM, PPS
Environmental standards
Enclosure class
Temperature cycling
Vibration (non-destructive)
Electromagnetic compatibility
IP44
IEC 68-2-14
20 to 2000 Hz, 10G, 4h
EN 61326-1
Dimensions
5.0
4.5
4.0
Sensing element
3.5
1.85 x 1.57 x 0.79 in.
[47 X 40 X 20 mm]
3.0
2.0
1.5
1.0
0.5
0.0
TM04 4458 1612
2.5
Fig. 153Temperature response
49
6
Grundfos Direct Sensor™
Specifications
Differential pressure sensor, standard 0-60 psi
series 100
Pressure
Measuring range
(differential)
Accuracy (±1˰), 77 to 176 °F
[25 to 80 °C]
Accuracy (±1˰), 32 to 212 °F
[0 to 100 °C]
Response time
System pressure deviation
Resolution
TM04 4457 1309
Differential pressure sensor, standard (DPS)
DPS 0-60 psi [0-4.0 bar]
Fig. 154DPS sensor
Dimension in. [mm]
TM04 4456 1612
1.89 in. [47.9 mm}
0.80 in. [20.2
0.80 in. [20.3
0.09 in. [2.3
0.08 in. [2 mm]
0.79 in. [20 mm]
[1.18
R 0.05 in.
5 mm]
0.06 in. [1.
0.44 in. [11.2
0.44 in. [11.2
0.57 in. [14.6
0.50 in. [12.6
Media and environment
Media
Media temperature
(operation)
Media temperature (peak)
Ambient air temp. (operation)
Ambient air temp. (peak)
Humidity (relative)
Fig. 155Dimensional sketches of sensing element
P1 is the high-pressure side
1.57 in. [40 mm]
Temperature
Measuring range
Accuracy (±1˰), 77 to 176 °F
[25 to 80 °C]
Accuracy (±1˰), 32 to 212 °F
[0 to 100 °C]
Response time, sensing
element to output change
Resolution
1.38 in. [35 mm]
1.30 in. [32.9 mm]
TM04 4455 1612
1/8-27 NPT
1.30 in. [33 mm]
1/8-27 NPT
1.22 in. [31 mm]
Application pressure P1
Fig. 156 Isometric view of housing for DPS
TM04 4453 1612
Output signals
Fig. 157Differential pressure response
Differential pressure P1 to P2
Burst pressure P 1
Burst pressure P 2
Electrical data
Power supply
Output signals
Pressure signal
Temperature signal
Power consumption
Load impedance
Sensor materials
Sensing element
Sealing Cap
Housing
Wetted materials
Environmental standards
Enclosure class
Temperature cycling
Vibration (non-destructive)
Electromagnetic compatibility
0 to 60 psi [0 to 4.0 bar]
±2 % FS
±2.5 % FS
< 0.5 s
0.09 psi/psi [6 mbar/bar]
0.06 psi [4 mbar]
32 to 212 °F [0 to 100 °C]
± 1.8 °F [± 1 °C]
± 3.6 °F [± 2 °C]
< 1.0 s
± 0.36 °F [± 0.2 °C]
Liquids, air, and gases
32 to 212 °F [0 to 100 °C]
-13 to 248 °F [-25 to 120 °C],
media must not freeze
-13 to 140 °F [-25 to 95 °C]
-67 to 194 °F [-55 to 90 °C]
0 to 95 %, non-condensing
Max. 232 psi at 158 °F
[Max. 16 bar at 70 °C]
Max. 174 psi at 212 °F
[Max. 12 bar at 100 °C]
Max. |145| psi [Max. |10| bar]
Max. 435.1 psi [Max. 30 bar]
Max. 145 psi [Max. 10 bar]
5 VDC (±5 %)
Ratiometric
0.5 to 4.5 V
0.5 to 4.5 V
< 50 mW
> 10 k˖
Silicon-based MEMS sensor
EPDM rubber
Composite (PPS)
Corrosion-res coating, EPDM, PPS
IP44
IEC 68-2-14
20 to 2000 Hz, 10G, 4h
EN 61326-1
Dimensions
5.0
Sensing element
4.5
4.0
3.5
3.0
2.0
1.5
1.0
0.5
0.0
Fig. 158 Temperature response
50
TM04 4458 1612
2.5
1.85 x 1.57 x 0.79 in.
[47 X 40 X 20 mm]
6
Specifications
Differential pressure sensor, standard 0-90 psi
series 100
Pressure
TM04 4457 1309
DPS 0-90 psi [0-6.0 bar]
Fig. 159DPS sensor
Dimension in. [mm]
TM04 4456 1612
1.89 in. [47.9 mm}
0.80 in. [20.2
0.80 in. [20.3
0.08 in. [2 mm]
0.09 in. [2.3
0.79 in. [20 mm]
[1.1 8
R 0.05 in.
mm
0.06 in. [1.5
]
0.44 in. [11.2
0.44 in. [11.2
0.57 in. [14.6
0.50 in. [12.6
Fig. 160Dimensional sketches of sensing element
P1 is the high-pressure side
1.57 in. [40 mm]
Measuring range
(differential)
Accuracy (±1˰), 77 to 176 °F
[25 to 80 °C]
Accuracy (±1˰), 32 to 212 °F
[0 to 100 °C]
Response time
System pressure deviation
Resolution
Measuring range
Accuracy (±1˰), 77 to 176 °F
[25 to 80 °C]
Accuracy (±1˰), 32 to 212 °F
[0 to 100 °C]
Response time, sensing
element to output change
Resolution
Media
Media temperature (opp)
Media temperature (peak)
Ambient air temp. (opp.)
Ambient air temp. (peak)
Humidity (relative)
TM04 4455 1309
1.30 in. [33 mm]
1.22 in. [31 mm]
1.30 in. [32.9 mm]
Fig. 161Isometric view of housing for DPS
Output signals
±2 % FS
±2.5 % FS
< 0.5 s
0.09 psi/psi [6 mbar/bar]
0.09 psi [6 mbar]
32 to 212 °F [0 to 100 °C]
± 1.8 °F [± 1 °C]
± 3.6 °F [± 2 °C]
< 1.0 s
± 0.36 °F [± 0.2 °C]
Media and environment
1.38 in. [35 mm]
1/8-27 NPT
0 to 90 psi [0 to 6.0 bar]
Temperature
Application pressure P1
1/8-27 NPT
Differential pressure sensor, standard (DPS)
Grundfos Direct Sensor™
Differential pressure P1 to P2
Burst pressure P 1
Burst pressure P 2
Liquids, air, and gases
32 to 212 °F [0 to 100 °C]
-13 to 248 °F [-25 to 120 °C],
media must not freeze
-13 to 140 °F [-25 to 65 °C]
-67 to 194 °F [-55 to 90 °C]
0 to 95 %, non-condensing
Max. 232 psi at 158 °F
[Max. 16 bar at 70 °C]
Max. 174 psi at 212 °F
[Max. 12 bar at 100 °C]
Max. |145| psi [Max. |10| bar]
Max. 435.1 psi [Max. 30 bar]
Max. 145 psi [Max. 10 bar]
Electrical data
Power supply (ground req)
Output signals
Pressure signal
Temperature signal
Power consumption
Load impedance
5 VDC (±5 %)
Ratiometric
0.5 to 4.5 V
0.5 to 4.5 V
< 50 mW
> 10 k˖
TM04 5111 1309
Sensor materials
Fig. 162Differential pressure response
Sensing element
Sealing Cap
Housing
Wetted materials
Silicon-based MEMS sensor
EPDM rubber
Composite (PPS)
Corrosion-res coating, EPDM, PPS
Environmental standards
Enclosure class
Temperature cycling
Vibration (non-destructive)
Electromagnetic compatibility
IP44
IEC 68-2-14
20 to 2000 Hz, 10G, 4h
EN 61326-1
Dimensions
5.0
4.5
4.0
Sensing element
3.5
1.85 x 1.57 x 0.79 in.
[47 X 40 X 20 mm]
3.0
2.0
1.5
1.0
0.5
0.0
TM04 4458 1612
2.5
Fig. 163Temperature response
51
7
Grundfos Direct Sensor™
Product range-RPI Transmitter
7. Product range-RPI Transmitter
Scope of delivery:
• RPI transmitter
• M12- 16.4ft [5 meter] cable
• Quick guide
Pressure range
Complete product
Thread
psi [bar]
Temperature
measurement
O-ring
Product number
EPDM
FKM
Ɣ
RPI
0 to 9
[0.6 bar]
G1/2"
Ɣ
Ɣ
Ɣ
Ɣ
Ɣ
Ɣ
0 to 14.5
[1.0 bar]
Ɣ
Ɣ
Ɣ
Ɣ
Ɣ
Ɣ
0 to 25
[1.6 bar]
Ɣ
Ɣ
Ɣ
Ɣ
Ɣ
Ɣ
0 to 40
[2.5 bar]
Ɣ
Ɣ
Ɣ
Ɣ
Ɣ
Ɣ
0 to 60
[4.0 bar]
Ɣ
Ɣ
Ɣ
Ɣ
Ɣ
Ɣ
0 to 90
[6.0 bar]
Ɣ
Ɣ
Ɣ
Ɣ
Ɣ
Ɣ
0 to 145
[10.0 bar]
Ɣ
Ɣ
Ɣ
Ɣ
Ɣ
Ɣ
0 to 232
[16.0 bar]
Ɣ
Ɣ
Ɣ
Ɣ
Ɣ
Ɣ
0 to 360
[25.0 bar]
52
Ɣ
Ɣ
Ɣ
97748907
97748948
97748926
97748957
97748908
97748949
97748928
97748958
97748909
97748950
97748929
97748959
97748910
97748951
97748930
97748960
97748921
97748952
97748941
97748961
97748922
97748953
97748942
97748962
97748923
97748944
Ɣ
Ɣ
97748963
97748924
97748955
97748945
97748964
97748925
97748956
97748946
97748955
8
Grundfos Direct Sensor™
Product range - RPS sensor
8. Product range - RPS sensor
• Scope of delivery
• RPS sensor
• Quick guide:
Pressure range
O-ring
psi [bar]
EPDM
0 to 9
[0.6 bar]
0 to 14.5
[1.0 bar]
0 to 25
[1.6 bar]
0 to 40
[2.5 bar]
0 to 60
[4.0 bar]
0 to 90
[6.0 bar]
0 to 145
[10.0 bar]
Ɣ
96701190
Ɣ
96701202
Ɣ
96701203
Ɣ
96701204
Ɣ
96657081
Ɣ
96701205
Ɣ
96701206
Complete product
RPS
Product number
53
9
Grundfos Direct Sensor™
Product range - DPS sensor
9. Product range - DPS sensor
• Scope of delivery
• DPS sensor
• Quick guide:
Pressure range
O-ring
psi [bar]
EPDM
0 to 9
[0.6 bar]
0 to 14.5
[1.0 bar]
0 to 25
[1.6 bar]
0 to 40
[2.5 bar]
0 to 60
[4.0 bar]
0 to 90
[6.0 bar]
Ɣ
96567838
Ɣ
96567839
Ɣ
96605149
Ɣ
96605144
Ɣ
96804557
Ɣ
96804558
Complete product
DPS
54
Product number
10
Grundfos Direct Sensor™
Product range - DPI transmitter V.2
10. Product range - DPI transmitter V.2
Scope of delivery:
• DPI V.2 transmitter
• M12- 16.4ft [5 meter] cable
• Capillary pipe
• Quick guide
Pressure range
Complete product
Thread
[psi]
Temperature
measurement
DPI
O-ring
Product number
EPDM
FKM
Ⴠ
0 to 9
G1/2"
Ɣ
Ɣ
Ɣ
Ɣ
Ɣ
Ɣ
0 to 14.5
Ɣ
Ɣ
Ɣ
Ɣ
Ɣ
Ɣ
0 to 25
Ɣ
Ɣ
Ɣ
Ɣ
Ɣ
Ɣ
0 to 40
Ɣ
Ɣ
Ɣ
Ɣ
Ɣ
Ɣ
0 to 60
Ɣ
Ɣ
Ɣ
Ɣ
Ɣ
Ɣ
0 to 90
Ɣ
Ɣ
Ɣ
Ɣ
Ɣ
Ɣ
0 to 145
Ɣ
Ɣ
Ɣ
Ɣ
Ɣ
Ɣ
0 to 232
Ɣ
Ɣ
Ɣ
Ɣ
Ɣ
97747194
97747215
97747202
97747244
97747195
97747216
97747203
97747195
97747196
97747218
97747204
97747246
97747197
97747219
97747205
96841440
97747198
97747220
97747206
96841441
97747199
97747241
97747207
97747250
97747200
97747242
97747208
97747251
97747201
97747243
97747209
97747252
Ɣ
0 to 360
Ɣ
Ɣ
Ɣ
Ɣ
Ɣ
55
11
Grundfos Direct Sensor™
Product range - DPI transmitter
11. Product range - DPI transmitter
The DPI transmitter is available as both single
transmitter and sets with capillary tubes.
Scope of delivery:
• DPI sensor
• Screws, nuts and washers necessary for installation
• Cable pin 0.01 in. [0.34 mm]
• Quick Guide
• See table below for special parts for each set.
Product description
DPI
DPI
DPI
DPI
DPI
DPI
DPI
DPI
DPI
DPI
DPI
DPI
DPI
DPI
DPI
DPI
DPI
DPI
DPI
56
0-0.6 Complete
0-1.0 Complete
0-1.6 Complete
0-2.5 Complete
0-4.0 Complete
0-6.0 Complete
0-10.0 Complete
0-0.6 Set 1
0-1.0 Set 1
0-1.6 Set 1
0-2.5 Set 1
0-4.0 Set 1
0-6.0 Set 1
0-10.0 Set 1
0-1.2 Set 2
0-2.5 Set 2
0-4.0 Set 2
0-6.0 Set 2
0-10.0 Set 2
Pressure
range [psi]
Cable length
ft [m]
Wall
bracket
0 to 9
0 to 14.5
0 to 25
0 to 40
0 to 60
0 to 90
0 to 145
0 to 9
0 to 14.5
0 to 25
0 to 40
0 to 60
0 to 90
0 to 145
0 to 17.4
0 to 40
0 to 60
0 to 90
0 to 145
5 [1.5]
5 [1.5]
5 [1.5]
5 [1.5]
5 [1.5]
5 [1.5]
5 [1.5]
5 [1.5]
5 [1.5]
5 [1.5]
5 [1.5]
5 [1.5]
5 [1.5]
5 [1.5]
16.5 [5]
16.5 [5]
16.5 [5]
16.5 [5]
16.5 [5]
Ɣ
Ɣ
Ɣ
Ɣ
Ɣ
Ɣ
Ɣ
Ɣ
Ɣ
Ɣ
Ɣ
Ɣ
Ɣ
Ɣ
Ɣ
Ɣ
Ɣ
Ɣ
Ɣ
Motor
bracket
Ɣ
Ɣ
Ɣ
Ɣ
Ɣ
Ɣ
Ɣ
Capillar
tube
Ɣ
Ɣ
Ɣ
Ɣ
Ɣ
Ɣ
Ɣ
Ɣ
Ɣ
Ɣ
Ɣ
Ɣ
Reducing piece
UNS 0.44"R0.25"
Ɣ
Ɣ
Ɣ
Ɣ
Ɣ
Ɣ
Ɣ
Ɣ
Ɣ
Ɣ
Ɣ
Ɣ
I&O
Product
number
Ɣ
Ɣ
Ɣ
Ɣ
Ɣ
Ɣ
Ɣ
Ɣ
Ɣ
Ɣ
Ɣ
Ɣ
Ɣ
Ɣ
Ɣ
Ɣ
Ɣ
Ɣ
Ɣ
96561232
96573681
96573682
96573683
96573684
96573685
96573686
96611522
96611523
96611524
96611525
96611526
96611527
96611550
96760247
96760248
96760249
96760250
96829235
12
Grundfos Direct Sensor™
Accessories
12. Accessories
Sensor interface, type SI 001 PSU
TM04 4194 0809
SI 001 PSU from Grundfos Direct Sensors™ is an
external power supply for the DPI and other
transmitters with 24 VDC supply voltage.
The power supply is to be used where the distance
between the transmitter and the controller is longer
than 100 ft [30 m].
Fig. 164Sensor interface, SI 001 PSU
Specification
• Voltage range: 110-400 VAC
• frequency range: 50-60 Hz
• ambient temperature: -20 to +50 °C
• enclosure class: IP54.
Part
Sensor interface, SI 001 PSU
Product No.
96915820
57
13
Grundfos Direct Sensor™
Further product documentation
13. Further product documentation
WebCAPS
WebCAPS is a Web-based Computer Aided Product
Selection program available on www.grundfos.com.
WebCAPS contains detailed information on more than
220,000 Grundfos products in more than
30 languages.
Information in WebCAPS is divided into six sections:
• Catalog
• Literature
• Service
• Sizing
• Replacement
• CAD drawings.
Catalog
Based on fields of application and pump types, this section
contains the following:
• technical data
• curves (QH, Eta, P1, P2, etc.) which can be adapted to the
density and viscosity of the pumped liquid and show the
number of pumps in operation
• product photos
• dimensional drawings
• wiring diagrams
• quotation texts, etc.
Literature
This section contains all the latest documents of a given pump,
such as
• data booklets
• installation and operating instructions
• service documentation, such as Service kit Catalog and
Service kit instructions
• quick guides
• product brochures.
Service
This section contains an easy-to-use interactive service Catalog.
Here you can find and identify service parts of both existing and
discontinued Grundfos pumps.
Furthermore, the section contains service videos showing you
how to replace service parts.
58
Sizing
0
Further product documentation
13
Grundfos Direct Sensor™
1
This section is based on different fields of application and
installation examples and gives easy step-by-step instructions in
how to size a product:
• Select the most suitable and efficient pump for your
installation.
• Carry out advanced calculations based on energy,
consumption, payback periods, load profiles, life cycle costs,
etc.
• Analyze your selected pump via the built-in life cycle cost tool.
• Determine the flow velocity in wastewater applications, etc.
Replacement
In this section you find a guide to selecting and comparing
replacement data of an installed pump in order to replace the
pump with a more efficient Grundfos pump.
The section contains replacement data of a wide range of pumps
produced by other manufacturers than Grundfos.
Based on an easy step-by-step guide, you can compare
Grundfos pumps with the one you have installed on your site.
When you have specified the installed pump, the guide will
suggest a number of Grundfos pumps which can improve both
comfort and efficiency.
CAD drawings
In this section, it is possible to download 2-dimensional (2D) and
3-dimensional (3D) CAD drawings of most Grundfos pumps.
These formats are available in WebCAPS:
2-dimensional drawings:
• .dxf, wireframe drawings
• .dwg, wireframe drawings.
3-dimensional drawings:
• .dwg, wireframe drawings (without surfaces)
• .stp, solid drawings (with surfaces)
• .eprt, E-drawings.
WinCAPS
WinCAPS is a Windows-based Computer Aided
Product Selection program containing detailed
information on more than 220,000 Grundfos products
in more than 30 languages.
The program contains the same features and functions
as WebCAPS, but is an ideal solution if an internet
connection is unavailable.
WinCAPS is available on DVD and updated once a
year.
Fig. 165WinCAPS DVD
Subject to alterations.
59
Being responsible is our foundation
Thinking ahead makes it possible
Innovation is the essence
L-DS-PG-002 0812
The name Grundfos, the Grundfos logo, and the payoff Be–Think–Innovate are registrated trademarks
owned by Grundfos Management A/S or Grundfos A/S, Denmark. All rights reserved worldwide.
ECM: -
GRUNDFOS Pumps Corporation
17100 West 118th Terrace
Olathe, Kansas 66061
Phone: +1-913-227-3400
Telefax: +1-913-227-3500
GRUNDFOS Canada Inc.
2941 Brighton Road
Oakville, Ontario L6H 6C9
Canada
Phone: +1-905 829 9533
Telefax: +1-905 829 9512
Bombas GRUNDFOS de Mexico S.A. de C.V.
Boulevard TLC No. 15
Parque Industrial Stiva Aeropuerto
Apodaca, N.L. Mexico 66600
Phone: +52-81-8144 4000
Telefax: +52-81-8144 4010