Downloaded from Advance Product Services Ltd. For repairs and replacements, visit http://www.advanceproductservices.co.uk FARNELL ADVANCE POWER KXF Range Power Factor Corrected Input 1500WMulti Output Power Supplies KXF RANGE - POWER FACTOR CORRECTED INPUT, 1500W MULTI OUTPUT SWITCH MODE POWER SUPPLIES • Up to 1500W output power with integral fan • Sinusoidal input current • Comprehensive signals facilities • Industry standard 5" x 8" x 11" packcage MAIN OUTPUTS AVAILABLE Voltage AUXILIARY OUTPUTS AVAILABLE Adjustment Range Current Output 5.0V 4.5 - 5.8V 200A BA 2.5V 5.2V 4.5 - 5.8V 200A BB 5V 5.5V 4.5 - 5.8V 200A BC 12V 8 -12.6V 15A D 15V 10 -15.7V 12A E 18V 12-19V 10A L 24V 16 -25V 7.5A F 28V 17 -29.5V 6.4A G 36V 26 -41V 4.5A H 48V 36 -57V 3.4A I 54V 36 - 57V 3.4A J Code A single power supply must contain one 'Main Output' module and may contain up to four "Auxiliary Output' modules in a single 5" x 8" x 11" package. All parameters are as defined in Farnell Advance Power document "Definition of Terms" unless otherwise stated. Voltage Adjustment Range Load Regulation All values are INPUT SPECIFICATION 176-264V r.m.s. Input Current 11A r.m.s. maximum at 240V input. 25A at 264V input. 45 - 65Hz. Supply Type Single phase TN-S systems (as defined in IEC364). i.e. systems with a separate earth conductor which is directly connected to the neutral conductor at the source. A B Anoutput is varied by 100% lMAX withall other outputs loaded to 20% lMAX. An input variation over the operating range of the unit with all outputs proportionally loaded to provide maximum rated output power causes a maximum output voltage variation of The output voltage variation of any output when any other output is varied from 10% lMAX to 100% lMAX is 0.05% for any auxiliary output. Dynamic Load Regulation An output load variation of 10% to 90% or90% to 10% with a5/<s risetime results in an output voltage deviation which 2200W maximum input power when delivering maximum rated output power. Phase Angle 20A 20A 0.05% of nominal. Cross Regulation Frequency Power 1.5 -3.0V 3.6 - 6.0V nominal. Line Regulation Peak Inrush Current Code Maximum voltage deviation is 0.2% of specified with an input voltage of 240V a.c. 50Hz and in an ambient temperature of 25°C unless otherwise stated. Voltage Range Current recovers to within 1% of its final value within 2ms. Temperature Coefficient Typically ±0.02%/°C on all outputs for temperatures within the operating Less than 5°. Apparent Power Factor Greater than 0.9. Typically 0.997. Efficiency Typically 72% when loaded to maximum Harmonic Distortion In accordance with the requirements of IEC555. Typically 2.9% THD. range. Ripple and Noise rated output power. With all outputs proportionally loaded to provide full output power, the differential output noise over the frequency range 10Hz -30MHz does not exceed 2% pk-pk of the nominal output voltage. OUTPUT SPECIFICATION Voltage Current Nominal output voltage and adjustment ranges are shown in Tables 1 and 2 above. Outputs are factory set to within 1% of the specified nominal. Recommended maximum continuous PROTECTION Input Fuse V* ceramic bodied fuse. Input Overvoltage range ofthe units. A minimum current of 37A is required on the main output for full current availability on auxiliary outputs. Power 1500W continuous up to 50°C. From 50°C to 70°C derate by 2.5%/°C. Units are protected by a latching shutdown system. current ratings (lMAX) are shown in Tables 1 and 2 above. It may not be possible to draw the full rated current from all outputs simultaneously due to the total power rating of the unit. All maximum current ratings are applicable over the full operating temperature Front panel mounted 15A T 250V 1V* x Output Current Limit All outputs have self resetting foldback current limit. The current limit point is set to 1.1 x rated maximum current. Short Circuit Current All outputs fold back to between 40% and 80% of rated maximum output current. Output Overvoltage All outputs are protected against overvoltage. Unit shutdown will occur at approximately 120% of factory set output voltage on all outputs except as Output in Limits output voltage is more than ±5% away from nominal. The output is active low, below: passive pull up to 5.6V (nom), with a 2.5V auxiliary output, 3.8V; 5V auxiliary output, 6.8V. drain capability of 5mA @ 0.5V. The unit is reset by interrupting the mains for at least 20s or by strobing the "Inhibit/ Isolated Shutdown" input. Overtemperature In the event of thermal overload, the unit will shut down. The unit is reset by allowing the internal temperature to reduce to a safe level and A logic output indicating all output voltages are within ±10% of nominal. Logic low indicates that at least one Current Meter An analogue output providing a meter drive signal for main output current monitoring. Output resistance is 3.15kS2 (± 10%) and the voltage at 1.1 x lMAX is 4V. Indicators either interrupting the mains for at least 20s or strobing the inhibit input. LED indicators are provided foroutput in limits; current limit; overvoltage trip; overtemperature trip. ISOLATION TURN ON AND TURN OFF CHARACTERISTICS All units have sufficient energy storage output isolation barriers, layout and wiring, are specified to 4kV a.c. r.m.s. for one minute. Where a safety earth is interposed between primary and secondary, this potential is applied as 2kV a.c. r.m.s. from input to earth and 2kV a.c. r.m.s. from output to earth. The complete unit is tested to 1.5kV a.c. to ride through a missing mains cycle when supplying full rated output power at nominal input. At low mains input, r.m.s. for 1 minute between a.c. input and d.c. output, with all output and signal ports connected together and Primary to Secondary Start-up Time Alloutputsare "withinlimits" within2sof application of input power at 240V. Start-up Characteristic Monotonic voltage rise with no overshoot on all outputs. Rate of rise is greater than 25Vs'1 from 5% to 95% of nominal output voltage. Hold Up Input to including 198V hold up >28ms. connected to earth. Primary to Earth AUXILIARY FUNCTIONS Units are tested to 1.5kV a.c. from input to earth. Remote Sense Available on all outputs of all units to compensate for up to 500mV total drop in the power leads. Secondary to Earth Parallel Operation All Earth Leakage Current modules shown are suitable for operation in parallel with other modules of the same type. Series Operation Outputs may be connected in series to provide output voltages up to 250V d.c. External Voltage Output voltage programming Units are tested to 500V a.c. from output to earth, with all output and signal ports connected together. Earth current under normal operating conditions does not exceed 3.5mA. Operating Voltages The maximum operating voltage between any output (power or signal) and earth or between isolated outputs must not exceed 250V. is achieved with an external resistor with a coefficient of 1kQ/V nom. The programming range extends from Won the main output and the minimum adjustment limit on auxiliary outputs to the maximum adjustment limit. The output power of a complete power Inhibit / Isolated Shutdown (Non-latching) supply may be inhibited by a logic signal applied to an isolated input. Individual auxiliary outputs may also be inhibited by a relay contact (5V, 10mA). Removal of the logic signal or the relay contact reinstates the output voltage. Latching Shutdown The complete unit may be inhibited by a logic signal. The output is reinstated by removing the signal and strobing the "Inhibit / Isolated Shutdown" signal or by removing the signal and then interrupting the mains for a period of at least 20s. Marginate The main output may be adjusted up or down by ±5% (±0.5%) by an external Power Fail Signal A complementary pair of logic outputs providing warning of failure due to loss of input. At least 5ms warning of output power loss due to a loss of mains input is provided. Outputs are open collecter with a maximum open circuit voltage of 12V and a drain capability of 5mA @ connection. 0.5V. ELECTROMAGNETIC COMPATIBILITY Exported Noise All units meet the requirements of BS6527 Class B; FCC Rules Part 15 Subpart J Class B; VDE0871 Class B. ENVIRONMENTAL CONDITIONS Ambient Temperature -10 to +70°C operating. See current and power ratings in output specification for any deratings required. -40 to +85°C non-operating. Humidity 0 to 95% R.H. non-condensing. Altitude -500 to 2,000m (-1,500 to 6,000ft) operating. -500 to 10,000m (-1,500 to 30,000ft) non-operating. Pollution These power supplies are designed for use in office type environments, i.e. pollution degree 2 environments, as defined in EN60950. KXF RANGE OUTLINE DRAWING K6-4 (5-76 in.) All dimensions are nominal and are in mm (inches) OUTPUT IN LIMITS rCURRENT LIMIT (0-24'lh. 0/P IN LIMITS SK 501 O/P VOLTS AOJ. AUXILIARY OUTPUT MOOULE {<!} MECHANICAL SPECIFICATION Mechanical Format All units are supplied enclosed with integral fan as standard. Mounting Orientation Units may be mounted orientation without derating. Ventilation and Cooling Units are cooled by an integral fan and requirefree airflow in the area of thefan atthe rear of the powersupply and over the ventilated front face of the power supply. External Dimensions All dimensions are nominal and are in ORDERING INFORMATION The order code consists of 5 fields: 1. Series : mm (inches). 1KX 127 (5.0) x 203 (8.0) x 279.4 (11.0) plus 6 (0.24) projection from the rear face. 2. Power Input Type F 3. Main Output : See table of modules 4. Auxiliary Outputs : Up to four from the table of modules. These must be put in alphabetical order. Any unused positions should be indicated by a '9'. 5. Airflow : H 1500W Corrected Mass 8.35kg (18.41b). Fixings 8 x M4 ISO standard threaded inserts are provided and are marked "a" on the outline drawing. The following connectors are fitted to the power supply: Connectors (Horizontal, integral fan) e.g. To order a 1500W power supply with corrected input, a 5V200A main output plus two 12V, 15A auxiliaries, and a 5V20A auxiliary with a horizontal integral fan, the order code is: Input 3 x 4BA terminal screws (with all necessary hardware). Main Output 2 x M8 ISO standard studs (with all necessary hardware). Auxiliary Outputs 2 x M4 ISO standard studs per output (with all necessary hardware). 1KX F BA BDD9 H GUARANTEE All Farnell Advance Power products are guaranteed against faulty manufacture and faulty components for a period of twelve months from the date of despatch. See conditions of sale for full details. Ref: 9FS0020E Issue: A November 1991 Auxiliary functions FARNELL ADVANCE POWER FARNELL ADVANCE POWER Southern Sales (& Production), 05-3061 on each auxiliary module. We reserve the right to amend specifications without prior notification Raynham Road, Bishop's Stortford, West Yorkshire, LS22 4DN. Hertfordshire, CM23 5PF. Tel: (0937) 581961 Tel: Fax: (0937) 586908 Fax: (0279) 655322 Telex: 557294 Telex: 81510 (0279) 655155 FARNELL ADVANCE POWER Inc. ADVANCE ELECTRONIC GmbH FARNELL ITALIA srl 32111 Aurora Road, Solon, Ohio. 44139. DieselstraRe21, ViaCeppo N 10, 6451 Mainhausen 2, Tel: 061 82/2 1091 Fax: 06182/2 8819 Tel: Fax: 039 599213 Telex: Telex: 315351 216 349 0755 216 349 0142 6182914 Molex 7478 series connectors. 2 x ref 22-05-3141 on main module and 1 x 22- Printed in the UK Northern Sales (& Production), Sandbeck Way. Wetherby, Tel: Fax: in any 22055 Merate, Como. 039 9907612