GRUV-HE-GRID, GRUV6-HE-GRID Installation Instructions

advertisement
INSTALLATION INSTRUCTIONS
GRUV-HE-GB/GRUV6-HE-GRID
689-0391
1 or 2 Lamp Fluorescent, Grid Ceiling
pg 1 of 4
WARNING: RISK OF FIRE AND ELECTRICAL SHOCK. FIXTURE MUST BE INSTALLED BY A QUALIFIED ELECTRICIAN ONLY.
FIXTURE IS INTENDED FOR INSTALLATION IN ACCORDANCE WITH THE NATIONAL ELECTRICAL CODE, LOCAL AND
FEDERAL SPECIFICATIONS. DISCONNECT POWER AT ELECTRICAL PANEL BEFORE SERVICING.
RETAIN THESE INSTRUCTIONS FOR MAINTENANCE REFERENCE.
Suspension Points
6.6”
6.6”
6.6”
X
X
X
13”
6.6”
Example of a Continuous Row
Individual Installation - (Individual fixture shipped as shown.)
FIXTURE TO BE INSTALLED PER NEC “MEANS OF SUPPORT” AND
ALL FEDERAL, NATIONAL AND LOCAL BUILDING CODES.
Bend-out
tabs
Wire ties (by others)
5/16” KO’s provided
for rod suspension
(rods not by Amerlux)
Bend #1
Fixture flange
4-3/4”
Fixture bend-out tabs,
pull out for correct height
4”
1. Ceiling grid to be installed. (By Others)
2. Installing contractor to verify ceiling grid
height and bend-out appropriate fixture tab
(typical 4 places).
3. Make sure shipped brace is secure during
installation. Lift fixture into place in ceiling grid,
handle fixture carefully to avoid bowing and/or
fixture distortion. Install fixture into ceiling grid,
making sure fixture flange rests on ceiling grid
and bend-out tabs are then pressed securely against
ceiling grid (see Bend #1), then bend-over against
bottom of grid bulb (see Bend #2). Note: To prevent
fixture from lifting during lens installation.
4. E.C. to secure fixture per NEC Code, via threaded rod,
wire ties or other means (hardware supplied by E.C.)
5. Make sure power is off at electrical panel. Remove
access plate on top of housing. Knock out K.O. as
required, make electrical connections (see access
plate detail pg 2)
6. Re-install access plate to housing.
7. Install correct lamps.
8. Remove shipping brace and install lens.
Bend #2
E.C. to confirm
measure height
9/16” Flat Tee
shown for ref.
9/16” Slot Grid
shown for ref.
Snap-in lens
GRUV (3-3/16”)
GRUV6 (5-3/16”)
Shipping brace
Loosen screw to
remove
GRUV (4”)
GRUV6 (6”)
Contractor’s Responsibility
to keep this dimension
before & after installation.
Amerlux® LLC | 178 Bauer Drive, Oakland, NJ 07436 | p: 973-882-5010 f: 973-882-2605 | www.amerlux.com
INSTALLATION INSTRUCTIONS
GRUV-HE-GB/GRUV6-HE-GRID
689-0391
1 or 2 Lamp Fluorescent, Grid Ceiling
pg 2 of 4
Assembling Continuous Rows
Note: With continuous rows, some assembly may be required in the field.
A. Housing Assembly
Joining the Housings
Line up the two housings by using the
alignment splines. Secure them
together by inserting the screws into
the joining brackets then sliding the
washer on then fastening the keps
nuts to the other side.
Screws, Washers, and
Keps Nuts for Joining
Fixtures
Alignment Spline
B. Reflector Assembly Installation
Bend tab to
prevent fixture
from lifting in
Grid (typical)
END OF RUN FILLER
Squeeze
Squeeze
3. Secure reflector to upper
area of extrusion via head
1. Connect wiring harness.
screws.
2. Insert the reflector by tilting 4. Install lens, starting at (1)
into housing.
end, squeeze lens legs IN to
(Caution: do not pinch wires) snap lens in place, continue
pressing upwards across
the length of the fixture, until
lens is secure.
END OF
RUN FILLER
- For continuous runs,
connect each reflector
assembly via quick
connect plugs before
installation.
- For staggered
lamp fixtures, filler pieces
will be supplied for the beginning and
end of run. They are to be secured
to the extrusion the same way as the
reflector assemblies.
Access Plate Detail Wiring Connection
Note: Additional connections (not shown)
as required for dimming, EM, or other
wiring requirements. Cap all unused leads.
(wire nuts supplied by other)
MAKE SURE TO DISCONNECT ALL ELECTRICAL CONNECTIONS BEFORE RELAMPING.
1. Install correct lamps.
2. Ballast maintenance.
See relamping label on reflector for the correct wattage.
Ballasts are located on opposite side of reflector.
Remove the screws mounting the reflector to access ballast.
Amerlux® LLC | 178 Bauer Drive, Oakland, NJ 07436 | p: 973-882-5010 f: 973-882-2605 | www.amerlux.com
INSTALLATION INSTRUCTIONS
GRUV-HE-GB/GRUV6-HE-GRID
689-0391
LED, Grid Ceiling
pg 3 of 4
WARNING: RISK OF FIRE AND ELECTRICAL SHOCK. FIXTURE MUST BE INSTALLED BY A QUALIFIED ELECTRICIAN ONLY.
FIXTURE IS INTENDED FOR INSTALLATION IN ACCORDANCE WITH THE NATIONAL ELECTRICAL CODE, LOCAL AND
FEDERAL SPECIFICATIONS. DISCONNECT POWER AT ELECTRICAL PANEL BEFORE SERVICING.
RETAIN THESE INSTRUCTIONS FOR MAINTENANCE REFERENCE.
Suspension Points
6.6”
6.6”
6.6”
X
X
X
13”
6.6”
Example of a Continuous Row
Individual Installation - (Individual fixture shipped as shown.)
FIXTURE TO BE INSTALLED PER NEC “MEANS OF SUPPORT” AND
ALL FEDERAL, NATIONAL AND LOCAL BUILDING CODES.
Bend-out
tabs
Wire ties (by others)
5/16” KO’s provided
for rod suspension
(rods not by Amerlux)
Bend #1
Fixture flange
4-3/4”
Fixture bend-out tabs,
pull out for correct height
4”
1. Ceiling grid to be installed. (By Others)
2. Installing contractor to verify ceiling grid
height and bend-out appropriate fixture tab
(typical 4 places).
3. Make sure shipped brace is secure during
installation. Lift fixture into place in ceiling grid,
handle fixture carefully to avoid bowing and/or
fixture distortion. Install fixture into ceiling grid,
making sure fixture flange rests on ceiling grid
and bend-out tabs are then pressed securely against
ceiling grid (see Bend #1), then bend-over against
bottom of grid bulb (see Bend #2). Note: To prevent
fixture from lifting during lens installation.
4. E.C. to secure fixture per NEC Code, via threaded rod,
wire ties or other means (hardware supplied by E.C.)
5. Make sure power is off at electrical panel. Remove
access plate on top of housing. Knock out K.O. as
required, make electrical connections (see access
plate detail pg 2)
6. Re-install access plate to housing.
7. Remove shipping brace and install lens.
Bend #2
E.C. to confirm
measure height
9/16” Flat Tee
shown for ref.
9/16” Slot Grid
shown for ref.
Snap-in lens
GRUV (3-3/16”)
GRUV6 (5-3/16”)
Shipping brace
Loosen screw to
remove
GRUV (4”)
GRUV6 (6”)
Contractor’s Responsibility
to keep this dimension
before & after installation.
Amerlux® LLC | 178 Bauer Drive, Oakland, NJ 07436 | p: 973-882-5010 f: 973-882-2605 | www.amerlux.com
INSTALLATION INSTRUCTIONS
GRUV-HE-GB/GRUV6-HE-GRID
689-0391
LED, Grid Ceiling
pg 4 of 4
Continuous Rows Installation
Note: With continuous rows, some assembly may be required in the field.
A. Housing Assembly
#8-32 Screw
Female Cap
Male Plug
Latch
Catch
Alignment Pins
1. Connect fixture to previous
fixtures power via quick connect.
2. Line up fixtures using alignment pins.
When fixtures are aligned, secure
with Catch/Latch.
3. Once latched, secure fixture with
#8-32 screw.
B. Reflector Assembly Installation
Bend tab to
prevent fixture
from lifting in
Grid (typical)
Squeeze
Squeeze
3. Secure reflector to upper
1. Connect wiring harness.
area of extrusion via head
2. Insert the reflector by tilting screws.
into housing.
4. Install lens, starting at (1)
(Caution: do not pinch wires) end, squeeze lens legs IN to
snap lens in place, continue
pressing upwards across
the length of the fixture, until
lens is secure.
- For continuous runs,
connect each reflector
assembly via quick
connect plugs before
installation.
- For staggered
lamp fixtures, filler pieces
will be supplied for the beginning and
end of run. They are to be secured
to the extrusion the same way as the
reflector assemblies.
Access Plate Detail Wiring Connection
Black
Purple
DIM “+”
Gray
DIM “_”
White Green
Note: Additional connections (not shown)
as required for dimming, EM, or other
wiring requirements. Cap all unused leads.
(wire nuts supplied by other)
MAKE SURE TO DISCONNECT ALL ELECTRICAL
CONNECTIONS BEFORE RELAMPING.
WARNING: Electrostatic and polarity sensitive device. Use caution while handling and wiring.
1. LED Fixture:
2. LED Replacement:
3. Driver Maintenance:
Consult Amerlux for LED maintenance.
For LED board replacement reference 689-0394 Instruction Sheet.
Drivers are located on Fixture Housing behind reflector. Remove the reflector mounting screws to access.
Note driver resistance value during driver maintenance.
Amerlux® LLC | 178 Bauer Drive, Oakland, NJ 07436 | p: 973-882-5010 f: 973-882-2605 | www.amerlux.com