MuYi Shanghai Muyi Electric Co.,Ltd Introduction of Muyi 1 Company overview Quality Control Product series Sales reference Partners Service muyi_electric@163.com MuYi Muyi Shanghai Muyi Electric Co.,Ltd • Established in 2006,located in Jiading district of Shanghai • Mainly engaged in design, production, sales and service of intelligent control and online monitoring equipment which applicable to the transformer • The agency of A. Eberle GmbH & Co. KG/Germany for products of OLTC control and transformer monitoring system • Established cooperation with many well-known manufacturers and Company research institutions in domestics and overseas • The local control panels and remote transformer control cabinets supplied to Chinese transformer manufactures have been exported to over 40 countries in America, Europe, Asia, Africa and Oceania Overview • Professional engineering team quickly provides the design and drawings according to the request 2 muyi_electric@163.com MuYi Shanghai Muyi Electric Co.,Ltd Product Series 3 Control panel Accessories Agency product • Remote transformer control cabinet (RTCC) • Transformer local control panel(LCP) • Transformer marshalling kiosk • Intelligent monitoring cabinet • Neutral earthing resistor disconnector • OLTC position indicator • OLTC position transmitter • Alarm annunciator • Hygrostat and thermostat • Heater • Protective housing for transformer secondary circuit • OLTC automatic voltage regulator • Transformer top oil and winding temperature monitoring device • Online Dissolved Gas Analyzer • Transformer accessories muyi_electric@163.com MuYi Shanghai Muyi Electric Co.,Ltd Product Series Remote Transformer Control Cabinet(RTCC) • The housing is made of high quality sheet steel coated with fine painting, it is for in-door application All electrical devices and elements are chosen from wellknown international brands Status of the OLTC and Transformer are displayed on the panel, various alarms can be given according to requirements of the clients Realize transformers operating in parallel with control functions Has OLTC automatic voltage regulating function With transformer winding temperature and top oil temperature real-time digital display Customized all kinds of transformer operation monitoring and control functions according to user needs • • • • • • 4 muyi_electric@163.com MuYi Shanghai Muyi Electric Co.,Ltd Product Series Remote Transformer Control Cabinet(RTCC) indicator Overall dimensions : 2200(height)×600 (width)×600(depth) Alarm 2200(height)×800 (width )×600(depth) There doors in front and rear It can be customized according to requirement 5 AVR Select switch Push button muyi_electric@163.com MuYi Shanghai Muyi Electric Co.,Ltd Product Series Remote Transformer Control Cabinet(RTCC) • Display voltage on transformer primary or secondary winding • OLTC position indication Digital Indicator • Transformer top oil temperature indication 6 • Transformer winding temperature indication muyi_electric@163.com MuYi Shanghai Muyi Electric Co.,Ltd Product Series Remote Transformer Control Cabinet(RTCC) It can be selected alarm lamp or alarm annunciator, the maximum number of alarm window is 36 in generally Buchholz relay main tank alarm Dial type thermometer for winding LV-b alarm Dial type thermometer for winding LV-c alarm Protective relay trip Thermometer for top oil trip Dial type thermometer for winding LV-c trip 7 Oil level indicator main tank alarm Standby oil level indicator for OLTC alarm Dial type thermometer for top oil alarm Dial type thermometer for winding HV-A alarm Dial type thermometer for winding HV-B alarm Dial type thermometer for winding HV-C alarm Dial type thermometer for winding LV-a alarm Standby Pressure relief valve main tank 1 trip Pressure relief valve main tank 2 trip Buchholz relay main tank trip protective relay for OLTC trip Rapid pressure rise relay trip Dial type Dial type thermometer thermometer for winding for winding HV-A trip HV-B trip Dial type thermometer for winding HV-C trip Dial type thermometer for winding LV-a trip Dial type thermometer for winding LV-b trip Fan group 2 power fault Main power 2 running Fan group 1 running Fan group 2 running Flow shutting valve trip Fan group 1 power fault Main power 1 running muyi_electric@163.com MuYi Shanghai Muyi Electric Co.,Ltd Product Series Remote Transformer Control Cabinet(RTCC) Basic function: l Automatic voltage regulating and control for on-load tap changer l Large backlit LCD with all important information (tap-change position, voltage, etc.) l Measuring functions (U, I, P, Q, S, cos ϕ, ϕ, I sin ϕ, f ) l Recorder functions (2-channel chart recorder) l Statistics function (records total number of switching operations, switching operations per tap) REG-DA & REG-D l Event recorder (log book), such as transformer monitoring functions incl. recording of the hot-spot temperature and lifetime consumption l Programmable binary inputs and outputs, and analogue inputs or outputs (mA) l The current and voltage ratings programmed l Realize transformer parallel operation up to 10 units l Serial and Ethernet SCADA protocols supported: IEC 61850, IEC 60870-5-103, IEC 60870-5-101,DNP3:00, LONMark, SPABUS, MODBUS RTU 8 muyi_electric@163.com MuYi Shanghai Muyi Electric Co.,Ltd Product Series Remote Transformer Control Cabinet(RTCC) Select switch and push button Select switch: OLTC: local/remote Parallel operation: master/follower /independent /off manual /auto push button: OLTC: raise /lower/stop fan group start fan group stop 9 muyi_electric@163.com MuYi Shanghai Muyi Electric Co.,Ltd Product Series Remote Transformer Control Cabinet(RTCC) view of cabinet inner wiring 10 RTCC with transparent double door and control of 3 units of singlephase transformer muyi_electric@163.com MuYi Shanghai Muyi Electric Co.,Ltd Product Series Remote Transformer Control Cabinet(RTCC) ♦ BCD position signal output ♦ one-to-one corresponding position signal output RTCC required the signals from OLTC ♦ tap changing in progress output signal N/O ♦ raise or lower signal N/O ♦ limit position signal output N/O ♦ tap changing incomplete signal output N/O ♦ power failure signal output N/O 11 muyi_electric@163.com MuYi Shanghai Muyi Electric Co.,Ltd Product Series Transformer Local Control Panel (LCP) l Housing is made of high quality stainless steel, it has beautiful appearance, corrosion and rust proof l All electrical components are selected well-known international brands and have reliable quality l With main backup power switching circuit in distributed arrangement, to ensure the cooling system operation effectively l Switching cooler automatically according to transformer top oil temperature changes l Switching cooler automatically according to transformer loads l With manual / automatic / remote control mode l PLC(programmable logic controller) or solid state relay fan control cabinet is as optional. 12 muyi_electric@163.com MuYi Shanghai Muyi Electric Co.,Ltd Product Series Transformer Local Control Panel (LCP) Technical spec. required from transformer producer Protective degree, material, overall dimensions and mounting request Number of fan group Power and current of fan and oil pump, voltage of control circuit 13 Painting color Transformer wiring terminal arrangement (when LCP includes marshalling kiosk function) Required devices on LCP panel and power feedequipment muyi_electric@163.com MuYi Shanghai Muyi Electric Co.,Ltd Product Series Transformer Local Control Panel (LCP) remote alarm signal and operation status signal output Alarm signal Status signal Main power supply fail Backup power supply fail Control circuit fail Heating circuit fail Fan fail 14 Fan running Fan stop muyi_electric@163.com MuYi Shanghai Muyi Electric Co.,Ltd Product Series Transformer Local Control Panel (LCP) Additional signals required when LCP includes function of fan control and marshalling kiosk Alarm signal Buchholz relay main tank alarm Oil level indicator main tank alarm Oil level indicator OLTC alarm Dial type thermometer for winding alarm Dial type thermometer for top oil alarm 15 Trip signal Rapid pressure rise relay main tank trip Pressure relief valve main tank trip Buchholz relay main tank trip Protective relay for OLTC trip Winding temperature high trip Top oil temperature high trip muyi_electric@163.com MuYi Shanghai Muyi Electric Co.,Ltd Product Series Transformer Marshalling Kiosk Ø Housing is made of high quality stainless steel, it has beautiful appearance, corrosion and rust proof Ø All electrical components are selected well-known international brands and have reliable quality Ø Using special sealing structure for outdoor application to ensure good sealing performance Ø Heater, Thermostat and Humidistat as well as fan is optional, to prevent moisture or condensation inside the cabinet 16 muyi_electric@163.com MuYi Shanghai Muyi Electric Co.,Ltd Product Series Transformer Marshalling Kiosk Technical spec. required from transformer producer Protective degree, material, overall dimensions and mounting request as well as painting color Transformer wiring terminal arrangement Power spec, special equipment and electric elements required 17 muyi_electric@163.com MuYi Shanghai Muyi Electric Co.,Ltd Product Series Transformer Marshalling Kiosk Alarm signal Buchholz relay main tank alarm Oil level indicator main tank alarm Oil level indicator OLTC alarm Dial type thermometer for winding alarm Dial type thermometer for top oil alarm 18 Remote alarm and trip signal output Trip signal Rapid pressure rise relay main tank trip Pressure relief valve main tank trip Buchholz relay main tank trip Protective relay for OLTC trip Winding temperature high trip Top oil temperature high trip muyi_electric@163.com MuYi Shanghai Muyi Electric Co.,Ltd Product Series Accessories for RTCC and LCP Type MY-C100 OLTC position transmitter u Binary coded decimal(BCD) position signal input u Binary coded decimal(BCD) position signal output u 4~20mA analog signal output u 0~5V analog signal output u Resistance position signal output Type LT100 OLTC position indicator n Use 8-segment LED display n Decimal and BCD position input n Binary coded decimal(BCD) position signal output 19 muyi_electric@163.com MuYi Shanghai Muyi Electric Co.,Ltd Product Series Accessories for RTCC and LCP l Alarm indication window can be selected by number 16,26 and 36 inputs according to request. l Each alarm indication lamp can be set normal light up or flash. l Working status and parameter can be displayed on LCD front panel. l With RS485 communication interface and Modbus protocol for remote control. l There are push buttons of test, set, reset and acknowledge. 20 MYAU Alarm Annunciator Unit muyi_electric@163.com MuYi Shanghai Muyi Electric Co.,Ltd Product Series Accessories for RTCC and LCP Heater WSKZ-TH Thermostat and Hygrostat Ø Small volume and easy for installation Ø Reliable operation with life time Ø Real time temperature and humidity display Ø Has working status indication lamp 21 p Heating wire is made of High quality nickel chromium alloy, use silicon rubber heating plate and aluminum heating plate. p Small volume and good appearance p Large surface area to have uniform heat dissipation p Long life time p With protective housing muyi_electric@163.com MuYi Shanghai Muyi Electric Co.,Ltd Product Series Agent product from A-Eberle Transformer control and monitoring system schematic overview 22 muyi_electric@163.com MuYi Shanghai Muyi Electric Co.,Ltd Product Series Agent product from A-Eberle The voltage regulation system REGSys™ has been designed to regulate, control and monitor power transformers with on-load tap changer (OLTC) in medium and high voltage grids. REGSysTM Transformer control and monitoring system A variety of freely programmable inputs and outputs, LEDs and intelligent features , recorder and logbook, transducer, statistics, parallel operation with ParaGramer function, transformer monitoring and a powerful programming language make the voltage regulation system very convenient. 23 muyi_electric@163.com MuYi Shanghai Muyi Electric Co.,Ltd Product Series Agent product from A-Eberle REGSysTM Transformer control and monitoring system Recorder REG-D(A) and PAN-D u The default recording function allows the recording up to three measuring values (e.g. voltage, current, angle, oil temperature or winding temperature) and to display them in form of a Y-t diagram. u With the recording control voltage, tap position, set point, tolerance band and manual/auto state are included in the registration in a time correlated manner. u In case of an event the analysis of all data can be done directly on the regulator or via the PC. The fault can then be analyzed using the history data too. u In addition, the REG-D™ can be equipped with feature S2. An extended recorder function with a total number of 256 channels is then available. A time resolution up to one second makes this version ideal for use in the transformer monitoring environment. u The data is archived and visualized with the REGView add-on software which can be integrated into the standard WinREG operating software. 24 muyi_electric@163.com MuYi Shanghai Muyi Electric Co.,Ltd Product Series Agent product from A-Eberle REGSysTM Transformer control and monitoring system Logbook REG-D(A) and PAN-D u All events essential for the clarification of fault situations are registered here. The last 512 events are stored chronologically with time and date according to FIFO principle. Statistics REG-D(A) u When assessing regulation knowing the total number of all steps per time unit is not sufficient. Information as to which taps were switched how often under load is also required. The statistic feature provides this information and thus acts as key characteristic to improve the quality of the regulation. 25 muyi_electric@163.com MuYi Shanghai Muyi Electric Co.,Ltd Product Series Agent product from A-Eberle REGSysTM Transformer control and monitoring system Transformer Monitoring Module (TMM) REG-D(A) u The life of a transformer depends essentially on the hot spot temperature. It is calculated by measuring the oil temperature and current in conjunction with key transformer characteristics according to IEC 60354 or IEC 60076. u Using this data the Transformer Monitoring Module TMM, integrated in the voltage regulators, determines the residual life time of the transformer u It is additionally able to even control up to six fan groups and two oil-pumps. The operating times of the fans and oil pumps can be recorded at the same time. The SMART Fan Control function provides the control of the fan (groups) by using the expected winding temperature, which increases the power reserves of the transformer. u The additional Overload Prediction function offers further tools for the optimal utilization of the transformer. 26 muyi_electric@163.com MuYi Shanghai Muyi Electric Co.,Ltd Product Series Agent product from A-Eberle REGSysTM Transformer control and monitoring system Transducer u The transducer function of the REG-D(A) provides measured values from three phase networks with balanced or unbalanced load. All measuring variables required to analyzing. the measuring situation at the feeding point are clearly displayed on the LCD. The measuring variables can also be provided through mA outputs or via SCADA connection. Parallel operation ParaGramer REG-D(A) u A certain management effort is always required when two or more transformers are operated in parallel according to the master/follower or minimizing the circulating current method. u The ParaGramer function automates the detection of parallel operation. It uses a single line diagram of the substation to detect the parallel operation. In the master/follower program the selection of the master takes place automatically. Alternatively, the auxiliary MSI (master / slave / independent) can be used to explicitly select the function of a regulator via binary input or SCADA connection. 27 muyi_electric@163.com MuYi Shanghai Muyi Electric Co.,Ltd Product Series Agent product from A-Eberle REGSysTM Transformer control and monitoring system Background programs REG-D(A) and PAN-D u The PLC functionality of the REGSys™ voltage regulation system with the proprietary REG-L programming language makes it especially flexible and powerful. Customer specific solutions can be implemented quickly and efficiently by employing so called background programs. Some examples are: Ø Regulating a transformer bank Ø Realizing additional limit values Ø Modifying certain parameters at runtime Ø Generating additional operating menus and thus parameters 28 muyi_electric@163.com MuYi Shanghai Muyi Electric Co.,Ltd Product Series Agent product from A-Eberle REGSysTM Transformer control and monitoring system SCADA communication REG-D(A) and PAN-D u The REGSys™ voltage regulation system supports all common SCADA protocols such as Modbus RTU, SPA-Bus, Profibus-DP, DNP 3, DNP via Ethernet, IEC 60870-5-101/-103/-104 and IEC 61850. Furthermore, solutions for remote maintenance (ComServer) and networking of remote regulators (ELAN over Ethernet) are available. Parameterization and visualization software WinREG/REGView u The WinREG program is available for convenient parameterization, programming and archiving. The base program can be expanded for different tasks in modular fashion. These are in detail: Ø REGView, consisting of data collector (Collector) and recorder, to archive and visualize REGSys™ recorder data Ø WinTM to parameterize the Transformer Monitoring Module of the REG-D(A) and for visualization Ø WinDM to parameterize the REG-DM(A) (pure transformer monitoring device) 29 muyi_electric@163.com MuYi Shanghai Muyi Electric Co.,Ltd Product Series Agent product from A-Eberle REGSysTM Transformer control and monitoring system Monitoring unit(s) PAN-D, PAN-A1, PAN-A2 u As supplement to the voltage regulators the REGSys™ voltage regulating system includes the monitoring units PAN-D, PAN-A1 and PAN-A2. Principally, these devices provide an additional voltage monitoring. Ø If the voltage is too high or too low the regulating commands are physically interrupted into the respective direction from the voltage regulator to the tap changer. Ø The units PAN-A1 and PAN-A2 and PAN-D can signal, in addition, limit violations via relay. Ø PAN-D is based on the same platform as REG-D and offers even more functions while convenience is enhanced at the same time (WinREG, background programs, SCADA communication). Hardware expansions and connectivity ANA-D, BIN-D u The already very flexible and comprehensive hardware equipment of the REG-D(A) voltage regulators can be expanded even further by utilizing ANA-D analogue interfaces (mA inputs or mA outputs) and BIN-D binary interfaces (binary inputs or outputs). These modules are connected via the standard available COM3 interface. 30 muyi_electric@163.com MuYi Shanghai Muyi Electric Co.,Ltd Product Series Agent product from A-Eberle REGSys™ product features General Data Supply voltage: AC/DC 88...264 V or DC 18...72V Communication interfaces: 3xRS232, 2xELAN Measurement current input: 1/5A Number of set point values: four Range of set point values: 60...140V Max. number of ELAN devices: 255 SCADA protocols: IEC 60870-5-101, IEC 60870-5-103 IEC 60870-5-104, IEC 61850 MODBUS RTU, SPABUS Profibus DP DNP 3.0 ,DNP 3.0 via Ethernet 31 muyi_electric@163.com MuYi Shanghai Muyi Electric Co.,Ltd Product Series Agent product from A-Eberle REGSys™ product features Please refer to REG-D(A) technical data for product code selection 32 muyi_electric@163.com MuYi Shanghai Muyi Electric Co.,Ltd Product Series Agent product from A-Eberle REG-DGA online dissolved gas monitors ü Analysis of the gases dissolved in oil is recognized as the most useful tool for early detection and diagnosis of incipient faults in power transformers ü By online monitoring key fault gases and moisture, additional cost reductions and safety improvements can be achieved. ü Easy installation on operational transformers ü Light weight ü No moving parts ü Voltage supervision in two levels ü Analysis like Duval’s Triangle, Roger’s Ratio, Dornenburg’s Ratio ü Integration with REGSysTM ü Optional on board GSM 33 muyi_electric@163.com MuYi Shanghai Muyi Electric Co.,Ltd Product Series Agent product from A-Eberle REG-DGA online dissolved gas monitors REG-DGA HC 01+c ü Composite measurement of the key gases ü Two Analogue and four relay outputs 34 REG-DGA HC HC 03 03 REG-DGA ü Individual measurement of moisture and ü 单独对湿气及关键气体的独立测量 the key gases ü 通讯接口RS232,RS-485 ü Communication interfaces RS232, RS 485 ü ü 可选的内置GSM和模拟调制解调器进 Optional on-board GSM and analog 行远程通讯 modems for remote communication muyi_electric@163.com MuYi Shanghai Muyi Electric Co.,Ltd Product Series Agent product from A-Eberle REG-DGA online dissolved gas monitors ü Individual measurement of moisture and the key gases ü Communication interfaces ETHERNET and RS 485 ü Optional on-board GSM and analog modems for remote communication REG-DGA HC 05 35 REG-DGA HC 08 muyi_electric@163.com MuYi Shanghai Muyi Electric Co.,Ltd Products Series Deputy product from GE HYDRAN*M2 online dissolved gas monitors HYDRAN*201i online dissolved gas monitors GE Kelman online dissolved gas monitors 36 muyi_electric@163.com MuYi Shanghai Muyi Electric Co.,Ltd Product Series Deputy product from GE • GE terminal block • EB25/26/27 37 muyi_electric@163.com MuYi Shanghai Muyi Electric Co.,Ltd Partner A-Eberle Germany Morgan schaffer Canada MUYI Calisto online dissolved gas monitors made by Morganschaffer Qualitrol U.S.A. Qualitrol 505ITM & 509ITM intelligent transformer monitors GE U.S.A. 38 muyi_electric@163.com MuYi Shanghai Muyi Electric Co.,Ltd Quality Control ü Design complying with relevant international standard ü Select famous brand of electric equipment and elements ü Perfect and rigorous factory test verification 39 muyi_electric@163.com MuYi Shanghai Muyi Electric Co.,Ltd Our customers Qiantang River Electric Co.,Ltd. (QRE) JiangSu HuaPeng Transformer Co., Ltd. (JSHP) Zhejiang jiangshan Transformer Co.,Ltd. (JSB) Sanbian Sci-Tech Co., Ltd. (SANBIAN) Liaoning EFACEC Electric Equipment Co.,Ltd (EFACEC) Main users in transformer production Chint Electric Co.,Ltd.(CHINT) 40 Shenda Electric Group Co.,Ltd. (SHENDA) Shandong Dachi Electric Co.,Ltd. (DACHI) Siemens Transformer (Guangzhou) Co., Ltd.) muyi_electric@163.com MuYi Shanghai Muyi Electric Co.,Ltd • CongoKinshasa • South Africa • Tanzania • Zambia • Nigeria • Kenya • Zimbabwe 41 Europe and Oceania Africa • Ukraine • Kazakhstan • Belarus • Bangladesh • Sri Lanka • Iran • Iraq • Saudi Arabia • Yemen • Syria • Jordan • Pakistan America • Vietnam • Thailand • Myanmar • Malaysia • Indonesia • Philippines • Brunei • India • Nepal Asia The products have been exported to over 40 countries worldwide Asia Sales refeerence • Dominica • Trinidad and Tobago • Ecuador • Venezuela • Peru • Chile • Paraguay • Uruguay • Fiji • Papua New Guinea muyi_electric@163.com MuYi Shanghai Muyi Electric Co.,Ltd Service and technical support Reply customer within 24-48 hours after receiving of email and phone call After service (domestic) within 24-48 hours after getting request After service for abroad customer is available 42 muyi_electric@163.com MuYi Shanghai Muyi Electric Co.,Ltd Thank you very much for your attention please feel free to contact us if you have any question or require technical support muyi_electric@163.com 43 muyi_electric@163.com