Multihead GU10 Kit Installation Instructions

advertisement
HALOGEN DOWNLIGHTS
Multihead GU10 Kit
Installation Instructions
6840
6841
6842
This light fitting has been designed and manufactured exclusively for B&Q
These instructions on wiring and installation are provided as a guideline to assist you. Some experience of electrical
wiring and do-it-yourself is required to install the light fitting. If at any time you are unsure of how to proceed, please
consult a qualified electrician.
Important!
Light fittings should be connected to a 5 amp fused circuit. This light fitting is suitable for indoor use only.
Before Starting
Please read through these instructions before commencing work, and keep them for future reference.
Please Take Extreme Care When Carrying Out These Instructions
Warning!
Always switch off electricity supply at the mains during installation and maintenance. We recommend that the fuse is
withdrawn or the circuit breaker is switched off whilst work is in progress. Do not just turn off at the wall switch.
All fittings must be installed in accordance with current IEE wiring regulations.
0.2m
SPOTLIGHTS GIVE A CONCENTRATED BEAM OF LIGHT AND MUST NOT BE
FITTED ANY CLOSER THAN 0.2M (20CM) TO THE ILLUMINATED SURFACE.
Location of Installation
These fittings have no special
protection against the ingress
of moisture and if they are to
be used in a bathroom they are
suitable for Outside Zones only.
(Ceiling use only)
F
Fittings marked with this
symbol are not suitable for
mounting on Flammable
surfaces, (eg Polystyrene
ceiling tiles and Wood
based materials)
Installation
Tools required: Key hole or electric hole saw, electrical screwdriver and file.
Fixing Dimensions
Type of Fitting
2 light Multihead Downlight
3 light Multihead Downlight
4 light Multihead Downlight
Replacement Bulb
50W GU10 Mains Voltage Halogen
50W GU10 Mains Voltage Halogen
50W GU10 Mains Voltage Halogen
Hole size
Min Ceiling Depth
75mmx 150mm
150mm
75mmx 235mm
150mm
155mmx 155mm
150mm
All measurements are based on a ceiling with a 12mm thickness. If your ceiling thickness is less than 12mm, deduct
approximately 5mm from the ceiling diameter shown above. If the ceiling is thicker than 12mm, gradually increase
the hole until a snug fit is acheived.
It is always recommended to cut the hole slightly smaller than the above mentioned, then file the hole until the
recessed unit fits snugly.
Ceiling Preparation
1) Ensure a minimum depth of ceiling void is available. (Use fixing dimensions overleaf)
2) If more than one downlight is to be installed, the distance between units must be no less than 0.3m (30cm).
3) Cut a mounting hole in the ceiling taking care not to foul any pipes or mains cables beneath the surface. (Use
fixing dimensions overleaf)
4) Ensure free movement of air around the fitting by removing any roof void insulation from at least 100mm
around the hole. Under no circumstances must these fittings be covered with insulating matting or similar
material.
Attaching the spring clips, friction washers and connection block
Silicone rubber washers have been supplied to add friction to the tilt mechanism. To fit simply stretch over one metal lug (see
diagram below). Attach the spring clips to the body of the recessed unit by squeezing the sides together and locating the spring coils
over the two metal tabs. Ensure the longer arm of the clip is uppermost and the shortest points away from the bulb.
Attach the connection block assembly to the recessed unit with the small screw fitted to the unit.
Wiring
1) Draw the mains cable through the hole in the ceiling. (Use minimum 1.0mm2 core cable).
2) Remove the cover from the terminal block.
3) Connect the incoming live and neutral cable to the terminals. Live supply to the terminal marked L, (brown wire)
and neutral supply to the terminal marked N (blue wire) (See Below). Ensure connections are tight.
This unit is double insulated and must not be earthed. If there are any incoming earth cables, they
must be joined together and well insulated with good quality insulation tape. This is to ensure earth continuity throughout your property.
4) Replace the cover onto the terminal block.
Fitting
Decide on the desired direction of tilt before fitting each unit.
1) Point the spring clips upwards and fit the two longer arms into the ceiling hole (See diagram 1 below).
2) Push the unit upward until firmly in position, ensuring that the cable is not trapped. (See diagram 2 below).
3) Fit the bulb into the lampholder by pushing in and twisting clockwise. Do not exceed the maximum wattage.
4) Push the bulb into the unit and secure by refitting the decorative bezel, or the wire retaining clip­­.
5) Replace the circuit fuse and switch on the mains to test.
To adjust tilt downlights push on rim of bulb housing - only adjust when bulb is cold.
Bulb replacement
1) Switch off and allow bulb to cool before replacing.
2) Remove wire retaining clip by squeezing tabs together, or turn decorative bezel ant-clockwise to release bulb.
3) Remove old bulb by pushing into lampholder and twisting anti-clockwise. Replace with Bulb type 50W Max GU10
Mains Voltage Halogen only.
4) Push the bulb into the unit and secure by refitting the decorative bezel, or the wire retaining clip­­.
'L'
Live
(Brown)
L
N
'N'
Neutral
(Blue)
This product should be disposed of responsibly at the end of its life. Please recycle where facilities exist. Check
with your Local Authority or retailer for recycling advice (Waste Electrical and Electronic Equipment Directive)
Poole Lighting Ltd
Product Helpline (01202) 690945
We have taken great care to ensure that this product reaches you in perfect condition. However, should any parts be damaged or missing please contact our Product Helpline.
This will save you the inconvenience of re-packing and returning the product to the store where purchased. Simply phone the number above and we will despatch to you, within
7 working days, your missing/damaged part. When phoning please ensure you have the following information available. This does not affect your statutory rights. Name and
Address, Daytime Telephone Number, Store and Date of Purchase, Product Reference (inside ceiling cover or on box label),Description of Missing/Damaged Part.
Additional Service
If you require replacement parts that are available, these can be dispatched for a charge either by telephoning the Product Helpline or writing to the following address:
Poole Lighting Ltd. Cabot Lane, Creekmoor, Poole, Dorset, BH17 7BY
090308
Download