installation instructions

advertisement
1
2
The luminaires
For illustration purposes the Tyrell 50 is shown as a typical example.
30
Connector
cover/block
12V Downlight luminaires
12V
I PI P
4141
12V
12V
3030
These luminaires
I 12V
P
IP
III
III
have a IP 41
41
LED
0.5 41
mrating.
30
IIIIII
Class 3 product.
0.50.5
m m
LED
LED
Cable
retainer
Luminaire
Lamp holder
Spring
Lamp
Directional
housing
Leaf springs
For illustration purposes the Tyrell 50 is shown as a typical example.
Tyrell
50 Shallow
Front bezel
35’s
Eldon
50 Shallow
This luminaire MUST be installed by a qualified electrician.
Read these instructions carefully. Once installation is complete give them
to the person responsible for general maintenance and cleaning.
Please keep these instructions for future reference.
Must not be closer than 0.5m
E
from
LEDthe illuminated surface.
Suitable for installation on
flammable surfaces.
EE
Cut-out
Lamp
Lamp cap
Circuit
Tyrell 35
60mm
MR11 20-35w
G4
12v
Tyrell 50
75mm
MR16 20-50w
G5.3
12v
Eldon 35
60mm
MR11 20-35w
G4
12v
Eldon 50
75mm
MR16 20-50w
G5.3
12v
Tyrell 50 Shallow
75mm
MR16 20-50w
G5.3
12v
Eldon 50 Shallow
75mm
MR16 20-50w
G5.3
12v
Lamp
Eldon
35 & 50
E0.5 m
4
Zones
Only for use in ‘Outside Zones’ - All areas outside of Zone 0, 1 and 2.
Not splash proof and not to be used in areas affected by condensation or
moisture.
Zone 1
Outside Zone
Zone 1
Wiring
Installation & maintenance guide
Tyrell
35 & 50
3
Technical data
50’s
95
75
75
95
95
88
88
60cm
60cm
60cm
Zone 2
Zone 0
Zone 2
Zone 2
1.5
2.5
4.0
20w
4.3m
6.4m
10.6m
35w
2.5m
3.7m
6.1m
10.4m
50w
1.7m
2.6m
4.2m
6.6m
Use correct cable size depending on lamp wattage. The dimensions above
(metres) refer to the max distance from the transformer to the luminaire.
This table is indicative only for the purpose of providing a guideline, it is
ultimately the responsibility of the installer to ensure that the correct cable
95 size and type is used in conjunction with the transformer mounted at the
13
appropriate distance from the luminaire.
1313
Warnings!
WARNING! - TO PREVENT ELECTRIC SHOCK - Always
switch off electricity supply and circuit breaker or
withdraw the fuse before installation and maintenance.
Guarantee
Zone 0 - Inside the Bath or Shower (IP Rating: IP67, 12V).
5
Warnings!
• Use correct wattage and lamp type. NEVER exceed the wattage stated.
• Take care when using power tools, follow the safety instructions provided
with them.
• NEVER alter the luminaire in anyway from its original specification.
• This luminaire qualifies as WEEE and should be disposed of
accordingly.
• IMPORTANT ensure free air movement around the luminaire.
Remove any insulation material from at least 100mm around the hole.
• DO NOT dispose of this luminaire with normal household
waste, take to a local authority recycling centre.
• NEVER cover the luminaire with insulating or similar materials.
• Dispose of used lamps responsibly.
• Install luminaire in accordance with building regulations and the current
edition of the IEE wiring regulations (BS 7671: Requirements for
electrical installations).
• Dispose of packaging correctly after installation.
• Check for hidden pipes and cables before installation.
Cable size in mm²
1.0
2.250m
V. No: 01
2.250m
Tyrell 35 2033
Tyrell 50 2035
Eldon 35 2032
Eldon 50 2034
Tyrell 50 Shallow 2235
Eldon 50 Shallow 2234
• The lamp and metal surrounding the lamp can get very hot during use.
DO NOT locate luminaire where it could be accidentally touched during
operation.
• Due to the high temperatures produced by this luminaire, cable within
Zone 1 - An area above the Bath or Shower tray to an height of 2.25m
The
Light min
Corporation
Ltd
(“We”)
guarantee
this Current
product Device
in the UK
for 12
(IP
Rating:
IP44) if at
240V
a 30ma
Residuel
(RCD)
must be used. 400mm must be High Temperature Rated Silicone.
months from date of purchase. This guarantee is invalid if the product
Zone 2 - An area outside of Zone 1 up to a height of 2.25m (IP Rating IP44).
• Allow the luminaire to cool before replacing lamp or starting
is installed in an improper working environment or not according to
maintenance.
Outside
Zone
All
areas
outside
of
Zone
0,
1
and
2.
current I.E.E Wiring Regulations (BS7671), for improper use or has been
tampered with in any way. Should this product fail during the guarantee
• Due to the expansion rates of different materials used during
period it will be replaced free of charge, subject to correct installation and
manufacture, it is common for the luminaire to ‘click’ when cooling.
return of the faulty unit. We do not accept responsibility for any installation
costs associated with the replacement of this product. We reserve the
• Disconnect luminaire from mains supply or transformer before service,
13
right to alter specifications without prior notice. This does not affect your
maintenance or lamp replacement.
statutory rights.
• Transformers must be located a minimum of 100mm away from the
luminaire.
Transformers
The luminaire MUST be connected to a transformer and not directly
to the mains electricity supply.
We recommend one Light Corporation transformer per luminaire:
Part No. 9100 000.
Fire hoods
Take care when using fire hoods with luminaires.
The majority of problems occur due to incorrectly fitted and specified
hoods.
We recommend the Light Corporation Envirograph fire hood:
35’s - Part No. 8030 000
50’s - Part No. 8031 000
Follow the manufacturer’s installation instructions.
IMPORTANT! We do not accept liability for incorrectly specified or
poorly installed fire hoods.
Tools required: Suitable size hole cutter, Philips screwdriver,
Small flat-blade electrical screwdriver.
WARNING! - TO PREVENT ELECTRIC SHOCK - Always
switch off electricity supply and circuit breaker or
withdraw the fuse before installation and maintenance.
7
Installation
3. Lift the sprung lamp holder and angle it to the side.
Ease the lamp into holder, with a gentle rocking motion, until fully inserted.
Position the lamp into the directional housing.
IMPORTANT! If fitting dichroic lamps DO NOT touch the lamp reflector.
Hold the lamp by the rim.
8
Installation
4. Remove connector cover and block. Connect to the wires coming from
the transformer (no earth connection required). Ensure the connections
are tight (Diagram a).
Refit connector block and cover. Clamp the cable using cable retainer
(Diagram b).
Diagram a
If replacing an existing luminaire, make a note of the connections.
Tyrell 50, Eldon 50, Tyrell 50 Shallow, & Eldon 50 Shallow - 75mm hole
Lamp adjustment - Tyrell only
This only applies to the Tyrell luminaires, the Eldon luminaires are
not directional.
Once installed the direction of the light beam can be adjusted up to 30º by
angling the directional housing and rotating the inner bezel.
NOTE: 30° Is the maximum tilt available for Tyrell range the tilt angle
varies depending on the lamp type used, please contact our sales team
for further information.
The maximum tilt for the shallow versions of the Tyrell is 25°.
1. Cut the correct sized hole in the ceiling in the required position:
Tyrell 35, Eldon 35 - 60mm hole
Diagram b
9
The cut-out may need to be chamfered to achieve the maximum angle.
Lamp holder
CAUTION! - The lamp may be hot.
IMPORTANT! Avoid any joists, pipes or cables beneath the surface.
2. Transformers
The luminaire MUST be connected to a transformer and not directly
to the mains electricity supply. We recommend one Light Corporation
transformer per luminaire (Part No. 9100 000).
Install the transformer in accordance with IEE electrical regulations
(BS 7671).
IMPORTANT! Ensure correct rating of transformer is used for the total
lamp wattage. Electronic transformers need a minimum load to operate,
e.g. a 20-60VA transformer requires a minimum load of 20w.
Installation is now
complete.
11
Maintenance
WARNING! - TO PREVENT ELECTRIC SHOCK Always switch off electricity supply and circuit
breaker or withdraw the fuse before maintenance.
CAUTION! - The lamp may be hot. Leave to cool before replacing,
cleaning or making adjustments.
Replacing the Lamp
IMPORTANT! Make sure the replacement lamp is the exact specification
as stated in this guide under section 2 Technical Data.
Maintenance / Contacts
Pull back the lamp holder against the springs, angle it to the side and
remove the lamp.
Fully insert the replacement lamp into the holder using a careful rocking
motion. Pull back the lamp and lamp holder against the springs and
re-position securely inside the directional housing.
Re-fit the magnetic inner bezel back into the front bezel.
Cleaning
Only use a soft damp cloth when cleaning.
IMPORTANT! If fitting dichroic lamps DO NOT touch the lamp reflector.
Hold the lamp by the rim. Dichroic lamps must not be cleaned with
chemicals. Wipe clean with a cloth.
Turn off the light at the wall switch. Remove the magnetic inner bezel
from the front bezel to access the lamp. Allow to gently hang.
5. Push the connector block
through the cut-out.
Squeeze both leaf springs and
fully locate the luminaire into the
cut-out.
10
Directional
housing
Our full range of products are available at:
www.lightcorporation.com
Front bezel
Chamfered
cut-out
Ceiling
Magnetic inner bezel
Follow the safety and installation instructions supplied with the
transformer.
Magnetic
inner bezel
30º
The Light Corporation Ltd
Unit 3 North Bridge Road
Berkhamsted
Hertfordshire
HP4 1EF
United Kingdom
www.lightcorporation.com
e-mail:info@lightcorporation.com
IN
TR
S
Tel: +44 (0) 1442 216200
Fax: +44 (0) 1442 873136
S
Installation
N
6
UCTI
O
Download