1 2 The luminaires For illustration purposes the Tyrell 50 is shown as a typical example. 30 Connector cover/block 12V Downlight luminaires 12V I PI P 4141 12V 12V 3030 These luminaires I 12V P IP III III have a IP 41 41 LED 0.5 41 mrating. 30 IIIIII Class 3 product. 0.50.5 m m LED LED Cable retainer Luminaire Lamp holder Spring Lamp Directional housing Leaf springs For illustration purposes the Tyrell 50 is shown as a typical example. Tyrell 50 Shallow Front bezel 35’s Eldon 50 Shallow This luminaire MUST be installed by a qualified electrician. Read these instructions carefully. Once installation is complete give them to the person responsible for general maintenance and cleaning. Please keep these instructions for future reference. Must not be closer than 0.5m E from LEDthe illuminated surface. Suitable for installation on flammable surfaces. EE Cut-out Lamp Lamp cap Circuit Tyrell 35 60mm MR11 20-35w G4 12v Tyrell 50 75mm MR16 20-50w G5.3 12v Eldon 35 60mm MR11 20-35w G4 12v Eldon 50 75mm MR16 20-50w G5.3 12v Tyrell 50 Shallow 75mm MR16 20-50w G5.3 12v Eldon 50 Shallow 75mm MR16 20-50w G5.3 12v Lamp Eldon 35 & 50 E0.5 m 4 Zones Only for use in ‘Outside Zones’ - All areas outside of Zone 0, 1 and 2. Not splash proof and not to be used in areas affected by condensation or moisture. Zone 1 Outside Zone Zone 1 Wiring Installation & maintenance guide Tyrell 35 & 50 3 Technical data 50’s 95 75 75 95 95 88 88 60cm 60cm 60cm Zone 2 Zone 0 Zone 2 Zone 2 1.5 2.5 4.0 20w 4.3m 6.4m 10.6m 35w 2.5m 3.7m 6.1m 10.4m 50w 1.7m 2.6m 4.2m 6.6m Use correct cable size depending on lamp wattage. The dimensions above (metres) refer to the max distance from the transformer to the luminaire. This table is indicative only for the purpose of providing a guideline, it is ultimately the responsibility of the installer to ensure that the correct cable 95 size and type is used in conjunction with the transformer mounted at the 13 appropriate distance from the luminaire. 1313 Warnings! WARNING! - TO PREVENT ELECTRIC SHOCK - Always switch off electricity supply and circuit breaker or withdraw the fuse before installation and maintenance. Guarantee Zone 0 - Inside the Bath or Shower (IP Rating: IP67, 12V). 5 Warnings! • Use correct wattage and lamp type. NEVER exceed the wattage stated. • Take care when using power tools, follow the safety instructions provided with them. • NEVER alter the luminaire in anyway from its original specification. • This luminaire qualifies as WEEE and should be disposed of accordingly. • IMPORTANT ensure free air movement around the luminaire. Remove any insulation material from at least 100mm around the hole. • DO NOT dispose of this luminaire with normal household waste, take to a local authority recycling centre. • NEVER cover the luminaire with insulating or similar materials. • Dispose of used lamps responsibly. • Install luminaire in accordance with building regulations and the current edition of the IEE wiring regulations (BS 7671: Requirements for electrical installations). • Dispose of packaging correctly after installation. • Check for hidden pipes and cables before installation. Cable size in mm² 1.0 2.250m V. No: 01 2.250m Tyrell 35 2033 Tyrell 50 2035 Eldon 35 2032 Eldon 50 2034 Tyrell 50 Shallow 2235 Eldon 50 Shallow 2234 • The lamp and metal surrounding the lamp can get very hot during use. DO NOT locate luminaire where it could be accidentally touched during operation. • Due to the high temperatures produced by this luminaire, cable within Zone 1 - An area above the Bath or Shower tray to an height of 2.25m The Light min Corporation Ltd (“We”) guarantee this Current product Device in the UK for 12 (IP Rating: IP44) if at 240V a 30ma Residuel (RCD) must be used. 400mm must be High Temperature Rated Silicone. months from date of purchase. This guarantee is invalid if the product Zone 2 - An area outside of Zone 1 up to a height of 2.25m (IP Rating IP44). • Allow the luminaire to cool before replacing lamp or starting is installed in an improper working environment or not according to maintenance. Outside Zone All areas outside of Zone 0, 1 and 2. current I.E.E Wiring Regulations (BS7671), for improper use or has been tampered with in any way. Should this product fail during the guarantee • Due to the expansion rates of different materials used during period it will be replaced free of charge, subject to correct installation and manufacture, it is common for the luminaire to ‘click’ when cooling. return of the faulty unit. We do not accept responsibility for any installation costs associated with the replacement of this product. We reserve the • Disconnect luminaire from mains supply or transformer before service, 13 right to alter specifications without prior notice. This does not affect your maintenance or lamp replacement. statutory rights. • Transformers must be located a minimum of 100mm away from the luminaire. Transformers The luminaire MUST be connected to a transformer and not directly to the mains electricity supply. We recommend one Light Corporation transformer per luminaire: Part No. 9100 000. Fire hoods Take care when using fire hoods with luminaires. The majority of problems occur due to incorrectly fitted and specified hoods. We recommend the Light Corporation Envirograph fire hood: 35’s - Part No. 8030 000 50’s - Part No. 8031 000 Follow the manufacturer’s installation instructions. IMPORTANT! We do not accept liability for incorrectly specified or poorly installed fire hoods. Tools required: Suitable size hole cutter, Philips screwdriver, Small flat-blade electrical screwdriver. WARNING! - TO PREVENT ELECTRIC SHOCK - Always switch off electricity supply and circuit breaker or withdraw the fuse before installation and maintenance. 7 Installation 3. Lift the sprung lamp holder and angle it to the side. Ease the lamp into holder, with a gentle rocking motion, until fully inserted. Position the lamp into the directional housing. IMPORTANT! If fitting dichroic lamps DO NOT touch the lamp reflector. Hold the lamp by the rim. 8 Installation 4. Remove connector cover and block. Connect to the wires coming from the transformer (no earth connection required). Ensure the connections are tight (Diagram a). Refit connector block and cover. Clamp the cable using cable retainer (Diagram b). Diagram a If replacing an existing luminaire, make a note of the connections. Tyrell 50, Eldon 50, Tyrell 50 Shallow, & Eldon 50 Shallow - 75mm hole Lamp adjustment - Tyrell only This only applies to the Tyrell luminaires, the Eldon luminaires are not directional. Once installed the direction of the light beam can be adjusted up to 30º by angling the directional housing and rotating the inner bezel. NOTE: 30° Is the maximum tilt available for Tyrell range the tilt angle varies depending on the lamp type used, please contact our sales team for further information. The maximum tilt for the shallow versions of the Tyrell is 25°. 1. Cut the correct sized hole in the ceiling in the required position: Tyrell 35, Eldon 35 - 60mm hole Diagram b 9 The cut-out may need to be chamfered to achieve the maximum angle. Lamp holder CAUTION! - The lamp may be hot. IMPORTANT! Avoid any joists, pipes or cables beneath the surface. 2. Transformers The luminaire MUST be connected to a transformer and not directly to the mains electricity supply. We recommend one Light Corporation transformer per luminaire (Part No. 9100 000). Install the transformer in accordance with IEE electrical regulations (BS 7671). IMPORTANT! Ensure correct rating of transformer is used for the total lamp wattage. Electronic transformers need a minimum load to operate, e.g. a 20-60VA transformer requires a minimum load of 20w. Installation is now complete. 11 Maintenance WARNING! - TO PREVENT ELECTRIC SHOCK Always switch off electricity supply and circuit breaker or withdraw the fuse before maintenance. CAUTION! - The lamp may be hot. Leave to cool before replacing, cleaning or making adjustments. Replacing the Lamp IMPORTANT! Make sure the replacement lamp is the exact specification as stated in this guide under section 2 Technical Data. Maintenance / Contacts Pull back the lamp holder against the springs, angle it to the side and remove the lamp. Fully insert the replacement lamp into the holder using a careful rocking motion. Pull back the lamp and lamp holder against the springs and re-position securely inside the directional housing. Re-fit the magnetic inner bezel back into the front bezel. Cleaning Only use a soft damp cloth when cleaning. IMPORTANT! If fitting dichroic lamps DO NOT touch the lamp reflector. Hold the lamp by the rim. Dichroic lamps must not be cleaned with chemicals. Wipe clean with a cloth. Turn off the light at the wall switch. Remove the magnetic inner bezel from the front bezel to access the lamp. Allow to gently hang. 5. Push the connector block through the cut-out. Squeeze both leaf springs and fully locate the luminaire into the cut-out. 10 Directional housing Our full range of products are available at: www.lightcorporation.com Front bezel Chamfered cut-out Ceiling Magnetic inner bezel Follow the safety and installation instructions supplied with the transformer. Magnetic inner bezel 30º The Light Corporation Ltd Unit 3 North Bridge Road Berkhamsted Hertfordshire HP4 1EF United Kingdom www.lightcorporation.com e-mail:info@lightcorporation.com IN TR S Tel: +44 (0) 1442 216200 Fax: +44 (0) 1442 873136 S Installation N 6 UCTI O