HIGH PERFORMANCE PATCHING AND CLOSET SOLUTIONS
WITH MAXIMUM VERSATILITY TO MEET YOUR
EVER-CHANGING COMMUNICATIONS NEEDS.
Standards exceeding performance with industrial designs that will make
even the most demanding IT professionals smile.
Whether it’s our proprietary KATTTM Premises Distribution System or
our modular high density patch panels, Molex Premise Networks has
solutions that ensure your data will be transmitted flawlessly and your
telecommunications closets will stay organized.
Flexibility, convenient labeling features and rear cable management on
our patch panels ensure optimum bend radius and are just some of the
reasons you can count on Molex for all the moves, adds and changes
growing companies need to make.
Page 24
UTP CLOSET SOLUTIONS
In this section.....
Description
Page
TM
KATT Premises Distribution System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26
110 Style Premise Distribution System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27
HD Patch Panels - Category 5e and 6 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30
Rear Cable Management Trays . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Telco Patch Panels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .32
Router Patch Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .32
Mod Patch Panels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .33
EZ PatchTM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .34
Universal System Patch Panels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .35
Patch Cords . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .36
Cable (Draka-Molex Cabling Systems) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .37
Mod DType Adapters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .38
Mod-Mod Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .39
Twinax Baluns . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .39
Harmonicas . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .40
UTP Octopus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .41
Cable Markers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .41
Mod-Plugs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .41
SLT3TM Tester . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .42
IDC Punch Down Tools . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .43
Uniquely KATT
It is the IDC connection on our high density patch panels that
stands between flawless data transmission and signals that
become distorted or weakened. Molex Premise Networks high
density patching utilizes the patented KATT connector with a
unique "V" shaped connector that flexes rather than fatigues
when terminated. Years of installers telling us that the IDC
connection on our patch panels is one of the most robust in the
industry and that they love the convenience of being able to
terminate with most commonly used termination tools proves
that great industrial design is not just in the eye of the beholder.
Page 25
110 is a trademark of AT&T
UTP CLOSET SOLUTIONS
KATTTM PDS
Ideal for both voice and high-speed data applications, the wall-mount KATT Premises Distribution System
(PDS) is a superior high-density block-based system for structured cabling. Utilizing Molex Premise
Networks patented KATT connector technology, this is the most cost-effective and flexible interconnect
system available today.
KPD-00026
KATT PDS 100-Pair Base without Legs
Dimensions: 3.5"H x 10.75"W x 3.5"D
(89mm x 273mm x 89mm)
Shipping Weight: 5.7 oz. (160g)
KATT PDS 100 Pair Base
The 100 Pair Base is the key component in the wall-mount KATT PDS system. The wiring strips are
notched and marked to quickly identify 5-pair groups when lacing 25-pair backbone cable. The
designation strips are marked for 1, 2, 4 and 5-pair connectors and are available in colors to
easily identify specific sections of the PDS installation.
PART NO.
DESCRIPTION
Blocks and Connectors
KPD-00027
KATT PDS 100-Pair Base with Legs
Dimensions: 3.5"H x 10.75"W x 3.5"D
(89mm x 273mm x 89mm)
Shipping Weight: 13 oz. (330g)
KPD-00026
KPD-00027
KPD-00029
KPD-00030
100 Pair Block without Legs
100 Pair Block with Legs
100 Pair Block with 24 KATT K4 Connectors
100 Pair Block with 20 KATT K5 Connectors
KATT PDS 300 Pair Base
PART NO.
DESCRIPTION
Blocks and Connectors
KPD-00028
KPD-00041
KPD-00042
300 Pair Block with Legs
300 Pair Block with 72 KATT-K4 Connectors
300 Pair Block with 60 KATT-K5 Connectors
Rack Mount KATT PDS Panels
KPD-00028
KATT PDS 300-Pair Base with Legs
Dimensions: 10.5" H x 10.75" W x 3.5" D
(267mm x 273mm x 89mm)
Shipping Weight: 1 lb 7 oz. (652g) – with legs
Rack Mount KATT PDS Panels allow users to combine a block-based system with active equipment
on a 19" rack. 3U and 4U KATT PDS Panels are 200-pair patch panels with integral ring runs. The
block-based format affords individual pair management, which is not possible with RJ patching. Cross
connection can be defined as either 1, 2 or 4-pair channels at the installation stage. These panels
are a cost-effective, convenient solution to rack-mounted patching.
PART NO.
DESCRIPTION
Rack Mount Panel
36.B040G
3U KATT PDS Panel without connectors
Dimensions: 5.25"H x 19.0"W x 2.5"D
(133mm x 483mm x 63.5mm)
Shipping Weight: 2 lbs. 15 oz. (935g)
36.B040G
36.B020G
36.B029G
36.B022G
36.B023G
36.B028G
3U PDS Without Connectors
3U PDS With 48 KATT-K4 Connectors
3U PDS With 40 KATT-K5 Connectors
4U PDS Without Connectors
4U PDS With 48 KATT-K4 Connectors
4U PDS With 40 KATT-K5 Connectors
Connectors
36.B0060
36.B0260
36.B022G
4U KATT PDS Panel without connectors
Dimensions: 7.0"H x 19.0"W x 2.5"D
(178mm x 483mm x 63mm)
Shipping Weight: 4 lbs. (1.98kg)
KATT4 Connectors - Bag of 100
KATT5 Connectors - Bag of 100
KATT connectors allow two conductors to be terminated in one position.
This is ideal for voice applications where daisy chaining is required.
Page 26
UTP CLOSET SOLUTIONS
110 Style Connecting Block
The 100 and 300 Pair Blocks are the key components in the wall mount 110 Style Premise Distribution
System (PDS). The solidly constructed unit includes wiring strips that are marked to quickly identify 5-pair
groups when lacing 25-pair backbone cable and designation strips marked for 1, 2, 4 and 5-pair
connectors that are available in colors to easily identify specific sections of the PDS installation.
110 Style PDS 100 Pair Base
PART NO.
KPD-00026
110 Style PDS 100-Pair Base without Legs
Dimensions: 3.5"H x 10.75"W x 3.5"D
(89mm x 273mm x 89mm)
Shipping Weight: 5.7 oz. (160g)
DESCRIPTION
Blocks and Connectors
KPD-00026
KPD-00027
KPD-00045
KPD-00046
100 Pair Block without Legs
100 Pair Block with Legs
100 Pair Block with 24 C4 Connectors
100 Pair Block with 20 C5 Connectors
110 Style PDS 300 Pair Base
PART NO.
DESCRIPTION
Blocks and Connectors
KPD-00028
KPD-00047
KPD-00048
KPD-00027
110 Style PDS 100-Pair Base with Legs
Dimensions: 3.5"H x 10.75"W x 3.5"D
(89mm x 273mm x 89mm)
Shipping Weight: 13 oz. (330g)
300 Pair Block with Legs
300 Pair Block with 72 C4 Connectors
300 Pair Block with 60 C5 Connectors
Rack Mount 110 Style PDS Panels
Rack Mount 110 Style PDS Panels allow users to combine a block-based system with active equipment on
a 19" rack. 3U and 4U PDS Panels are 200-pair patch panels with integral ring runs. The block-based format affords individual pair management, which is not possible with RJ patching. Cross connection can be
defined as either 1, 2 or 4-pair channels at the installation stage. These panels are a cost-effective,
convenient solution to rack-mounted patching.
PART NO.
KPD-00028
110 Style PDS 300-Pair Base with Legs
Dimensions: 10.5"H x 10.75"W x 3.5"D
(267mm x 273mm x 89mm)
Shipping Weight: 1 lb 7 oz. (652g)
DESCRIPTION
Rack Mount Panel
36.B040G
KPD-00060
KPD-00061
36.B022G
KPD-00062
KPD-00063
3U PDS Without Connectors
3U PDS With 48 110-C4 Connectors
3U PDS With 40 110-C5 Connectors
4U PDS Without Connectors
4U PDS With 48 110-C4 Connectors
4U PDS With 40 110-C5 Connectors
36.B040G
3U 110 Style PDS Panel without connectors
Dimensions: 5.25"H x 19.0"W x 2.5"D
(133mm x 483mm x 63.5mm)
Shipping Weight: 2 lbs. 15 oz. (935g)
Connectors
KPD-00058
KPD-00059
110-C4 Connectors - Bag of 100
110-C5 Connectors - Bag of 100
36.B022G
4U 110 Style PDS Panel without connectors
Dimensions: 7.0"H x 19.0"W x 2.5"D
(178mm x 483mm x 63mm)
Shipping Weight: 4 lbs. (1.98kg)
Page 27
UTP CLOSET SOLUTIONS
KATTTM & 110 Style Tools & Accessories
PART NO.
DESCRIPTION
Tools and Adaptors (see page 43 for photos of all available IDC tools)
14-0401-001
KATT Loading Tool
Dimensions: 3.5”
(88mm)
Shipping Weight: 1 oz. (28g)
31-001
Deluxe IDC Punchdown Tool
Dimensions: 6.5” with blade
(165mm)
Shipping Weight: 6.0 oz. (168g)
36.0B.011.B0050
KATT Frame Adapter 568A/568B
Dimensions: 7.5"L x 1.25"W x .625"H.
(190mm x 31mm x 15mm)
Shipping Weight: 9 oz. (252g)
14-0401-001
31-001
31-001-1
KPD-00056
KPD-00057
36.0B.011.B0050
KATT Loading Tool
Deluxe IDC Punch Down Tool
Replacement 110 Blade
Standard Punch Down Tool
110 Multi-Pair Punch Down Tool
KATT Frame Adapter 568B
Colored Designation Strips (100 per Bag)
36.B0160
36.B0170
36.B0180
36.B0190
100-Pair Base Designation Strips – Purple
100-Pair Base Designation Strips – Grey
100-Pair Base Designation Strips – Blue
100-Pair Base Designation Strips – Brown
KATT & 110 Style Configurable Frame
The KATT PDS Configurable Frame enables KATT and 110 Style blocks and Ring Runs to be quickly and
easily mounted on a wall, ensuring a totally square and secure system. The frame is made of sturdy steel
and attaches to the wall using four keyhole slots. Components snap to the frame using the included
“Christmas tree” clips. Each frame accommodates up to seven 100-Pair Bases and/or Ring Runs.
They can be used in multiples to accommodate higher density PDS systems.
PART NO.
DESCRIPTION
36.C0010
KATT & 110 Style Configurable Frame
IDC Frame Mounting Kit
36.C0010
KATT & 110 Style PDS Configurable Frame
Dimensions: 25.5"H x 11.25"W x .625"D
(648mm x 285mm x 16mm)
Shipping Weight: 2 lbs. 13 oz. (1.2kg)
The kit allows four 100-Pair Bases to be horizontally mounted in a 19" equipment rack. The kit includes
one panel and all mounting hardware, and it occupies 5 rack positions. 100-Pair Bases and connectors
may be ordered separately.
PART NO.
DESCRIPTION
31.B005G
IDC Frame Mounting Kit
31.B005G
IDC Frame Mounting Kit
Dimensions: 8.72"H x 19.0"W x .60"D
(222mm x 482mm x 15mm)
Shipping Weight: 2 lbs. 10 oz. (1.2kg)
Page 28
UTP CLOSET SOLUTIONS
KATTTM & 110 Style Cable Management
The KATT and 110 Style Ring Runs provide complete horizontal and vertical cable management in one
unique product. Molex Premise Networks exclusive rings speed horizontal cable routing. The integral cable
retention feature forms a vertical wiring trough between rows of blocks. If a higher-density system is
needed, the ring footprint permits interchange with 100-pair bases.
PART NO.
DESCRIPTION
KPD-00053
36.B0024
KPD-00054
36.B0274
1U PDS Horizontal Cable Manager
2U PDS Horizontal Cable Manager
Wire Spool Vertical Cable Manager w/Screw
PDS Drip Tray
KPD-00053
1U PDS Horizontal Cable Manager
Dimensions: 1.73”H x 10.7”W x 4.37”D
(44mm x 272mm x 11mm)
Shipping Weight: 3.5 oz. (98g)
36.B0024
2U PDS Horizontal Cable Manager
Dimensions: 3.5"H x 19.0"W x 4.0"D
(88mm x 483mm x 102mm)
Shipping Weight: 2 lbs. 12.5oz. (1.2kg)
KATT & 110 Style Patch Cords
KATT and 110 Style Patch Cords are used to administer voice and data cross-connections on block-based
circuits. They can be attached to IDC connectors with one wire terminated in the IDC slot, allowing circuit
testing or system activity monitoring without disrupting customer activity. They come in factory-configured
versions and pair counts to suit all applications. A field-terminable version can be terminated to
Category 5e specifications.
•
•
•
•
Circuits can be changed by untrained personnel without tools
Polarized to prevent accidental reversal of block connections
Low insertion force eases installer strain
Gripping feature makes removal easy
PART NO.
DESCRIPTION
PART NO.
DESCRIPTION
110 Style Patch Cords
KATT Patch Cords
KPC-00001
KPC-00002
KPC-00003
KPC-00004
KPC 4-pair to 4-pair C5 3 ft. 10/Pkg
KPC 4-pair to 4-pair C5 7 ft. 10/Pkg
KPC 4-pair to 4-pair C5 10 ft. 10/Pkg
KPC 4-pair to 4-pair C5 15 ft. 10/Pkg
KPC-00058
KPC-00059
KPC-00060
KPC-00061
110-PC 4-pair to 4-pair C5E 4 ft. 1/Pkg
110-PC 4-pair to 4-pair C5E 7 ft. 1/Pkg
110-PC 4-pair to 4-pair C5E 10 ft. 1/Pkg
110-PC 4-pair to 4-pair C5E 15 ft. 1/Pkg
KPC-00070
KPC-00071
KPC-00072
KPC-00073
KPC 2-pair to 2-pair 3 ft. 10/Pkg
KPC 2-pair to 2-pair 7 ft. 10/Pkg
KPC 2-pair to 2-pair 10 ft. 10/Pkg
KPC 2-pair to 2-pair 15 ft. 10/Pkg
KPC-00054
KPC-00055
KPC-00056
KPC-00057
110-PC 2-pair to 2-pair C3 4FT 1/Pkg
110-PC 2-pair to 2-pair C3 7FT 1/Pkg
110-PC 2-pair to 2-pair C3 10FT 1/Pkg
110-PC 2-pair to 2-pair C3 15FT 1/Pkg
KPC-00066
KPC-00067
KPC-00068
KPC-00069
KPC 1-pair to 1-pair C3 3 ft. 10/Pkg
KPC 1-pair to 1-pair C3 7 ft. 10/Pkg
KPC 1-pair to 1-pair C3 10 ft. 10/Pkg
KPC 1-pair to 1-pair C3 15 ft. 10/Pkg
KPC-00050
KPC-00051
KPC-00052
KPC-00053
110-PC 1-pair to 1-pair C3 4 ft. 1/Pkg
110-PC 1-pair to 1-pair C3 7 ft. 1/Pkg
110-PC 1-pair to 1-pair C3 10 ft. 1/Pkg
110-PC 1-pair to 1-pair C3 15 ft. 1/Pkg
KPC-00074
KPC-00075
KPC-00076
KPC-00077
36.0B.010.B0050
KPC 4-pair to RJ45 C5E 3 ft. 10/Pkg
KPC 4-pair to RJ45 C5E 7 ft. 10/Pkg
KPC 4-pair to RJ45 C5E 10 ft. 10/Pkg
KPC 4-pair to RJ45 C5E 15 ft. 10/Pkg
KPC 4-pair to unterminated C5E 15 ft. 10/Pkg
KPC-00062
KPC-00063
KPC-00064
KPC-00065
110-PC 4-pair to RJ45 C5E 4 ft. 1/Pkg
110-PC 4-pair to RJ45 C5E 7 ft. 1/Pkg
110-PC 4-pair to RJ45 C5E 10 ft. 1/Pkg
110-PC 4-pair to RJ45 C5E 15 ft. 1/Pkg
Page 29
36.B0274
PDS Drip Tray
Dimensions: 3.5"H x 10.75"W x 4.25"D
(89mm x 273mm x 108mm)
Shipping Weight: 1 lb. 10 oz. (737g)
KPC-00001
KATT Patch Cord
Shipping Weight (10/Pkg): 1 Lb. 2.5 oz. (470g)
UTP CLOSET SOLUTIONS
HD Patch Panels
PID-00001, PID-00004
HD Patch 5e 24 Port 8W 568A/B
Dimensions: 1.75"H x 19.0"W x 1.62"D
(44mm x 483mm x 41mm)
Shipping Weight: 1 lb. 3.5 oz. (553g)
High Density Patch Panels are a versatile and economical product for cross-connecting between trunk
and horizontal cabling. They are available in 24 and 48 port versions which fit 1 and 2U positions
respectively and are also available in our newest ultra-high density 48 port 1U patch panel. Designed
with excellent port labeling systems and an optional Rear Cable Management Tray that maintains
TIA-approved bend radius required for Category 5e and proposed Category 6 specifications, the back
features new cable-strain relief plus KATT IDC contacts to allow wiring changes without damage to the
panel. All HD Patch Panels are compatible with standard termination tools.
PART NO.
DESCRIPTION
HD Patch 6 Standard Grade
PID-00066
PID-00067
HD Patch 6 24 Port 8W 568 A/B
HD Patch 6 48 Port 8W 568 A/B
HD Patch 5E Standard Grade
PID-00002, PID-00005
HD Patch 5e 48 Port 8W 568A/B
Dimensions: 3.5"H x 19.0"W x 1.62"D
(89mm x 483mm x 41mm)
Shipping Weight: 2 lbs. 14 oz. (1305g)
PID-00001
PID-00004
PID-00002
PID-00005
HD Patch 5E 24 Port 8W 568B
HD Patch 5E 24 Port 8W 568A
HD Patch 5E 48 Port 8W 568B
HD Patch 5E 48 Port 8W 568A
HD Patch 5E Standard Grade with Cable Management (See page 31 for Cable Management Tray)
PID-00007
PID-00010
PID-00008
PID-00009
HD Patch 5E 24 Port 8W 568B with 3 Cable Management Trays
HD Patch 5E 24 Port 8W 568A with 3 Cable Management Trays
HD Patch 5E 48 Port 8W 568B with 6 Cable Management Trays
HD Patch 5E 48 Port 8W 568A with 6 Cable Management Trays
COMING SOON TO MOLEX PREMISE NETWORKS!
PART NO.
DESCRIPTION
Coming Soon HD Patch 6 Specification Grade
PID-00077
HD Patch 6 24 Port 8W 568A/B (Shuttered)
Dimensions: 1.75"H x 19.0"W x 1.62"D
(44mm x 483mm x 41mm)
Shipping Weight: 1 lb. 3.5 oz. (553g)
PID-00077
PID-00078
PID-00079
PID-00080
PID-00083
PID-00084
HD Patch 6 24 Port 568 A/B Shuttered
HD Patch 6 48 Port 568 A/B Shuttered
Patch 6 24 Port 568 A/B Shuttered with 3 Cable Management Trays
Patch 6 48 Port 568 A/B Shuttered with 6 Cable Management Trays
HD Patch 6 24 Port 568 A/B Unshuttered
HD Patch 6 48 Port 568 A/B Unshuttered
Coming Soon HD Patch 5E Specification Grade
PID-00085
HD Patch 5e 24 Port 568B (Shuttered)
Dimensions: 1.75"H x 19.0"W x 1.62"D
(44mm x 483mm x 41mm)
Shipping Weight: 1 lb. 3.5 oz. (553g)
HD Patch Panel Port Labeling Color Options:
Insert color code in place of ** when ordering:
RD = Red, BL = Blue, GR = Green, RG = Orange, YL = Yellow,
PP = Purple
Icon Color Options:
Insert color code in place of ** when ordering:
01 = Almond, 02 = White, 04 = Black, 05 = Ivory, 08 = Light Grey,
RD = Red, BL = Blue, GR = Green, RG = Orange, YL = Yellow,
PP = Purple
PID-00085
PID-00086
PID-00087
PID-00088
PID-00090
PID-00091
HD Patch 5E 24 Port 568B Shuttered
HD Patch 5E 48 Port 568B Shuttered
HD Patch 5E 24 Port 568B Shuttered with 3 Cable Management Trays
HD Patch 5E 48 Port 568B Shuttered with 6 Cable Management Trays
HD Patch 5E 24 Port 568B Unshuttered
HD Patch 5E 48 Port 568B Unshuttered
Coming Soon Specification Grade Accessories
CSP-00019-**
CSP-00021-**
CSP-00022-**
CSP-00023-**
HD Patch Panel Port Labeling/Color Coded
Blank 6-Pack Icons
Data 6-Pack Icons
Voice 6-Pack Icons
Page 30
UTP CLOSET SOLUTIONS
Ultra-High Density Patch Panel
For those applications where closet space is at an absolute premium, you can get no greater density than
our new 48 port patch panel in a 1U configuration. For internet service providers, web hosting facilities,
data centers and other customers where ultra high density can mean the difference between profit and
loss, this product provides greater density than any modular patch panel on the market.
PART NO.
DESCRIPTION
Ultra-High Density PowerCat 5e Patch Panel
PID-00073
48 Port PowerCat 5E Patch Panel 1U
PID-00073
48 Port PowerCat 5e Patch Panel 1U
Dimensions: 1.75”H x 19”W x 1.62”D
(44mm x 482mm x 41mm)
Shipping Weight: 5 lbs. 5 oz. (2.76kg)
Rear Cable Management Tray
Achieving a fully Category 5e or proposed 6 compliant cable plant is easier than ever when you use the
unique Molex Premise Networks Rear Cable Management Tray. This add-on option features cable bend
radius guides that provide a safeguard for the customer who wants to ensure a properly installed
TIA-approved bend radius.
It also includes Velcro® tie-wraps that prevent over-compression of the cables during installation. Each Rear
Cable Management Tray services eight ports for a total of three trays per 24 ports. The tray is made of
clear Lexan® that permits light to pass through in dimly lit areas.
PART NO.
DESCRIPTION
25.B0410
CMA-00022
Rear Cable Management Tray Standard Grade – 3 per box
Rear Cable Management Tray Specification Grade – 4 per box
25.B0410
Rear Cable Management Tray
Dimensions: .5"H x 5.5"W x 3.25"D
(13mm x 140mm x 83mm)
Shipping Weight (3/Pkg): 6 oz. (170g)
The Rear Cable Management Tray is condensed with HD Patch 5E and HD Patch 6.
Rear view of HD Patch with Rear Cable Management Tray in use.
To avoid over compressing cables (which can potentially affect
Category 5e and 6 performance) secure them with the Velcro® tie wraps included.
Page 31
Velcro® is a registered trademark of Velcro USA
Lexan® is a registered trademark of GE Plastics
UTP CLOSET SOLUTIONS
Category 5 Telco Patch Panels
Molex Premise Networks Telco Patch Panels combine the ease and simplicity of 25 pair feeder cables with
the performance requirements of a category 5 structured cabling system. Feeder cable technology is a
must where it is necessary to connect a 10/100BASE-T hub with RJ-21 Telco connectors to a patch panel
in the wiring closet.
PMT-00008
48 Port Telco Panel
Dimensions: 3.50"H x 19.0"W x 1.0"D
(88mm x 483mm x 25mm)
Shipping Weight: 2 lb. 8 oz. (334g)
These panels are paramount in meeting the Category 5 PowerSum NEXT requirements of 32dB @ 100 MHz
– as specified by TIA/EIA 568 – while maintaining standard pair pin-outs (1-26, 2-27, etc.).
Constructed of rugged, yet lightweight aluminum, Molex Premise Networks Telco Patch Panels have an
attractive black finish with large write-on areas for port and panel identification. Telco patching is a snap
to install and is available in 10/100BASE-T (2-pair) and 568B (4-pair) wiring sequences.
PART NO.
DESCRIPTION
PMT-00007
PMT-00008
PMT-00009
Telco Patch 24 Port 10/100 Base-T
Telco Patch 48 Port 10/100 Base-T
Telco Patch 48 Port C5 568B
T1 Patch Panel
27.1F.241.B004G
24-Port, T1 Panel, 568B
Dimensions: 1.75"H x 19.0"W x 4.0"D
(44mm x 483mm x 102mm)
Shipping Weight: 1 lb. 12 oz. (794g)
Molex Premise Networks T1 Patch Panel provides network connections for 1.544 Mbps digital services.
Often referred to as a DS1 signal, T1 is a transmission repeater system used to carry digitized voice over
four-wire twisted-pair cabling.
PART NO.
DESCRIPTION
27.1F.241.B004G
24-Port, RJ48X, T1 Panel, 568B
Router Patch Panel
The Molex Premise Networks Router Patch Panel is a 1U configured, 19 inch category 3 panel. The Router
Patch Panel eliminates the need to terminate octal cables individually by providing four 68-pin SCSI connectors which are internally mapped out via a printed circuit board to thirty-two RJ45 ports. By eliminating
the typical 8-position fan out cables (as used by Cisco NM-16A and NM-32A routers), the Molex Premise
Networks Router Patch Panel provides a more efficient interconnect.
PART NO.
DESCRIPTION
PID-00089
1U 19” Category 3 Router Patch Panel
Page 32
UTP CLOSET SOLUTIONS
Mod Patch Panels
Mod Patch Panels provide simple, easy-to-use closet cross connects that convert 50-position feeder cables
to individual modular jack channels. They are available in 2, 4, 6 and 8-wire (24 AWG) polarizations.
All wiring is totally enclosed. A Velcro® cable retainer allows 50-position installation without tools.
Mod Patch Panels are available for USOC, 568A, 568B or 10BASE-T sequences. They come standard with
50-position female receptacles on rear of panel. Male 50-position connectors are optional.
PART NO.
WIRES PER
PORT
PORTS
NO. 50
POSITIONS
JACK
POSITIONS
RACK
POSITIONS
8
24
4
WE8W
1
2
4
6
8
25
48
24
24
1
4
3
4
WE2W
WE4W
WE6W
WE8W
1
2
1
1
4
4
24
48
2
4
WE8W
WE8W
1
2
EIA 568B/356A
27.6E.241.B004G
24 Port Mod Patch Panel
Dimensions: 1.75"H x 19.0"W x 1.62"D
(44mm x 483mm x 41mm)
Shipping Weight: 1 lb. 3.5 oz. (553g)
USOC
27.6E.259.B001G
27.6E.489.B001G
27.6E.249.B002G
27.6E.249.B003G
10BASE-T
27.6E.246.B002G
27.6E.486.B001G
These products are an acceptable choice for low-speed LANs. However, home run cabling and IDC style panels are preferred
for their higher performance characteristics. As an alternative, see the Telco panels on page 32.
Rear view of Mod Patch Panel showing 50 position connector.
Page 33
UTP CLOSET SOLUTIONS
EZ PatchTM
Molex Premise Networks EZ Patch is a economical category 6 or 5e patching solution. Available in 24- or
48- ports, the item can be customized for a category 6 or 5e solution with DataGate jacks, which are
sold separately.
PID-00033
EZ Patch 5e 24 Port Loaded
Dimensions: 1.75"H x 19.0"W x 1.0"D
(44mm x 483mm x 25mm)
Shipping Weight: 14.5 oz (411g)
1 lb. 7 oz. (652g) with EZ Bar
PID-00034
EZ Patch 5e 48 Port Loaded
Dimensions: 3.50"H x 19.0"W x 1.0"D
(88mm x 483mm x 25mm)
Shipping Weight: 1 lb. 7 oz. (652g)
1 lb. 15 oz. (879g) with EZ Bar
Other features:
• Lightweight aluminum panel has attractive black anodized finish
• Includes rack mounting hardware
• Large write-on area for individual port identification and panel designation
• EZ Bar – optional rear cable management panel aids proper cable bend radius
PART NO.
DESCRIPTION
PID-00033
PID-00034
PID-00035
PID-00036
CMA-00007
EZ Patch 5e 24 Port Loaded
EZ Patch 5e 48 Port Loaded
EZ Patch 6/5E 24 Port Unloaded Panel
EZ Patch 6/5E 48 Port Unloaded Panel
EZ Bar Cable Management Panel
KSJ-00013-**
KSJ-00001-**
DataGate 6 8W 568A/B w/Shutter
DataGate 5E 8W 568A/B w/Shutter
DataGate Color Options:
Insert color code in place of ** when ordering DataGate modules:
01 = Almond, 02 = White, 04 = Black, 05 = Ivory, 08 = Light Grey, RD = Red,
BL = Blue, GR = Green, RG = Orange, YL = Yellow, PP = Purple
CMA-00007
EZ Bar Cable Management Panel
Dimensions: 1.O”H x19.0”W x 1.5”D
(25mm x 483mm x 38mm)
Shipping Weight: 13 oz. (330g)
Page 34
UTP CLOSET SOLUTIONS
Universal System Patch Panels (USP)
Molex Premise Networks Universal System Patch Panels (USP) add versatility to your cabling systems.
Individually purchased USO II modules (refer to pages 16-19) snap in easily and come in a variety of
media including UTP, fiber and coax. You can combine media within a single panel, configuring and
reconfiguring your patching field in almost infinite combinations.
These steel USP panels have an attractive graphite-grey powdercoat finish. They are available in one,
two and three-position versions for a total of up to 48 multimedia channels (UTP, fiber, coax, etc.).
All USP Panels include rack mounting screws.
PUS-00008
1U USP Panel
Dimensions: 1.75"H x 19.0"W x .675"D
(44mm x 483mm x 17mm)
Shipping Weight: 1 lb. 1 oz. (482g)
The 1U USP Panel is ideal for smaller installations. It accepts eight USO II modules of any media.
Ordering requires a total of up to nine parts:
• One 1U USP Panel - Unloaded
• Eight USO II modules or blanks
The 2U USP Panel is also used in small installations but accepts USO II modules like the IBM data
module. Ordering requires a total of up to 17 parts:
PUS-00009
2U USP Panel
Dimensions: 3.5"H x 19.0"W x .675"D
(89mm x 483mm x 17mm)
Shipping Weight: 1 lb. 11 oz. (766g)
• One 2U USP Panel - Unloaded
• 16 USO II modules or blanks
The 3U USP Panel is appropriate for medium-sized installations. It comes in a kit consisting of one panel,
eight bezels and 16 captive mounting screws. When used in combination with USO II, 3U USP Panels
can match office outlets channel for channel, simplifying trouble shooting and maintenance. As moves
and changes are made, patching changes can be made by simply changing USO II modules. For optical
fiber applications, straight fiber modules must be used—not angled. Ordering requires a total of up
to 25 parts:
• One 3U USP Panel - Unloaded
• 24 USO II modules or blanks
PART NO.
DESCRIPTION
PUS-00008
PUS-00009
PUS-00010
1U USP Panel – Unloaded
2U USP Panel – Unloaded
3U USP Panel Kit – Unloaded
PUS-00010
3U USP Panel
Dimensions: 5.25"H x 19.0"W x .675"D
(133mm x 483mm x 17mm)
Shipping Weight: 2 lbs. (908g)
When using the 1U and 2U USP panels, terminate the wires on the USO II modules before snapping them into the panels.
The 3U USP panels utilize a mounting bezel and modules may be terminated either before or after mounting into the panel.
USP Panels are completely configurable using USO II modules (pgs. 17-19). This allows mixing of connector types within a
single panel.
Page 35
UTP CLOSET SOLUTIONS
Patch Cords with Strain Relief Boots
Molex Premise Networks Patch Cords with Strain Relief Boots are designed for the highest level of
performance and reliability. Our patch cords far exceed the category standards set by EIA/TIA and are
individually tested for continuity before leaving the factory. Constructed of 4-pair 24 AWG cable, each
patch cord is factory crimped with modular RJ-45 plugs at both ends and color-matched, anti-snag strain
relief boots. The 5e patch cords are available in seven great colors for coding specific applications or
office locations.
Patch Cords with Strain Relief Boots
PART NO.
DESCRIPTION
PCD-00050-**
PCD-00052-**
PCD-00054-**
PCD-00058-**
PCD-00038-**
PCD-00039-**
PCD-00040-**
PCD-00041-**
PCD-00042-**
PCD-00043-**
1m Patch Cord C6 (3.3 ft.)
2m Patch Cord C6 (6.6 ft.)
3m Patch Cord C6 (9.9 ft.)
5m Patch Cord C6 (16.5 ft.)
1 ft. Patch Cord C5E
3 ft. Patch Cord C5E
5 ft. Patch Cord C5E
7 ft. Patch Cord C5E
10 ft. Patch Cord C5E
15 ft. Patch Cord C5E
Color Options:
Insert one of the following color codes in place of ** when ordering patch cords:
OC = Red, OH = Blue, OE = Grey, OK = Yellow, OP = Purple, ON = Orange, OJ = Green
Page 36
UTP CLOSET SOLUTIONS
Draka-Molex Cabling Systems
Draka USA, a multibillion dollar cable manufacturer has joined forces with Molex Premise Networks
to establish a new customer/vendor partnership standard, Draka-Molex Cabling Systems. Draka-Molex
addresses three fundamental issues essential to the long-term success of corporate enterprises: truly
significant presence–dedicated to supporting cabling system applications everywhere; massive test and
development capability–dedicated to unsurpassed cabling system performance; and, industrial design
innovation–dedicated to enhanced cabling system manageability.
Draka-Molex offers three warranted copper channel solutions: Bronze, Silver and Gold and comprehensive
fiber solutions (refer to page 65 for fiber). All warranted and all exceeding, with ample headroom, the
EIA/TIA standards in their category. You choose the system that best meets your requirements and DrakaMolex will provide you with the peace of mind inherent when you align with two multibillion dollar
industry leaders.
PART NO.
DESCRIPTION
805508
705508
705708
804508
704508
704708
803308
703408
701308
SuperCAT1000 Category 6 UTP Plenum
SuperCAT1000 Category 6 UTP Non-Plenum/Riser
SuperCAT1000 Category 6 UTP Non-Plenum Patch
SuperCAT360 Enhanced Category 5e UTP Plenum
SuperCAT360 Enhanced Category 5e UTP Non-Plenum/Riser
SuperCAT360 Enhanced Category 5e UTP Non-Plenum Patch
SuperCAT100E Category 5e UTP Plenum
SuperCAT100E Category 5e UTP Non-Plenum/Riser
SuperCAT100E Category 5e UTP Non-Plenum Patch
Draka-Molex Copper Systems
HD Patch 5e
SuperCAT100E
CAT 5e
DataGate 5e
12
8
10
4
TIA/EIA Cat 5e
ISO 11801 Class D
100 Base-T
155 ATM
HD Patch 5e
EZ Patch 5e
SuperCAT360
Enhanced CAT 5e
DataGate 5e
18
8
17
4
TIA/EIA Cat 5e
ISO 11801 Class D
Gigabit Ethernet
HD Patch 6
EZ Patch 6
SuperCAT1000
CAT 6
DataGate 6
29
19
28
16
TIA/EIA Proposed Cat 6
ISO 11801 Class E
Gigabit Ethernet
Category 6 applications require the use of the Draka-Molex 6 Patch Cords
100m CHANNEL PowerSum ACR
100m CHANNEL PowerSum ACR
-100
-100
100m Channel PowerSum ACR
-90
-80
-90
-80
-70
-60
Blue
-50
Green
-40
Orange
-30
Brown
PSACR (dB)
CAT 5e Limit
-20
Blue
Green
-60
-50
Orange
Brown
CAT 6 Limit
-40
-30
-20
-10
-10
100m CHANNEL PowerSum ACR
-100
0
Freq. (MHz)
PSACR (dB)
Freq. (MHz)
-60
Blue
-50
Green
-40
Orange
-30
Brown
CAT 5E
Limit
-10
0
Freq. (MHz)
Page 37
298.7
265.6
232.5
Freq. (MHz)
199.4
166.4
133.3
100.2
67.1
34.1
1.0
10
299.3
269.4
239.6
209.8
180.0
150.1
Freq. (MHz)
-70
-20
Helix/HiTemp Cables, Inc.
Chromatic Technologies, Inc.
120.3
1.0
-80
Freq. (Mhz)
90.5
10
-90
99.44
90.55
81.55
72.66
63.66
54.77
45.77
36.88
27.88
9.99
18.99
1.00
10
60.7
0
30.8
PSACR (-dB)
-70
UTP CLOSET SOLUTIONS
Mod Dtype Adapters
One of the more common data communications interfaces is the 25-pin Dtype connector. Of the (up to) 25 pins
on equipment, few carry active signals. Normally, eight pins or less are functionally required. This allows the use
of easy-to-handle, cost-effective adapters and line cords. Available in 9 or 25-pin male or female versions.
Molex Premise Networks offers Dtype adapters unwired in individually-packaged kits for field assembly or
pre-wired in standard or custom configurations.
06-888-999-00, 06-988-999-00
25-Pin Dtype Adapter Kit
Dimensions: .64"H x 2.10"W x 2.10"D
(16mm x 53mm x 53mm)
Shipping Weight: 1.5 oz. (42g)
Adapter Kits include:
• Slate (grey) shells with no logo
• Set of mounting screws
• Modular jack with flying leads (Dtype contacts crimped on)
• D subminiature connector
PART NO.
DESCRIPTION
25-Pin Dtype Kits
06-888-999-00
06-988-999-00
WE8W Male
WE8W Female
9-Pin Dtype Kits
08-888-999-00
08-988-999-00
WE8W Male
WE8W Female
08-888-999-00, 08-988-999-00
9-Pin Dtype Adapter Kit
Dimensions: .64"H x 1.30"W x 2.70"D
(16mm x 33mm x 68mm)
Shipping Weight: 1.25 oz. (35g)
Page 38
UTP CLOSET SOLUTIONS
MOD-MOD Kits
MOD-MOD Kits (Pig Tail Not Included)
09-KIT-00
Includes 2 WE8W, & 1 Blank
For termination tools please contact Molex Premise Networks.
Twinax Baluns
MOD-MOD Adapter Kit
Molex Premise Networks Twinax Baluns convert twinax interfaces for operation over twisted pair cable.
They are designed for use with IBM Systems 36/38/AS400.
PART NO.
JACK POLARIZATION
ACTIVE PINS
LEAD TYPE
88-810-80-000
WE8W(USOC)
5/4
None
88-810-80-000
Twinax Balun with no lead
Length: 3.375" (65.7mm)
Shipping Weight: 2.5 oz. (71g)
Page 39
UTP CLOSET SOLUTIONS
Harmonica
A Harmonica breaks out a 25-pair feeder cable into modular jacks and is typically used in open style
offices with modular or movable partitions. It is molded of fire-retardant ABS plastic. If rack mounting
of multiple units is required, use Mod Patch Panels.
PART NO.
NO. OF WIRES
CHANNELS
JACK POLARIZATION
GENDER
USOC
22-344-20
4-Wire Harmonica
Dimensions: .98"H x 8.10"W x 1.50"D
(25mm x 206mm x 38mm)
Shipping Weight: 4.8 oz. (136g)
22-38Y-21
8-Wire Harmonica
Dimensions: .98"H x 4.20"W x 1.50"D
(25mm x 107mm x 38mm)
Shipping Weight: 3 oz. (85g)
22-344-20
4
12
WE4W
F
8
6
WE8W
F
EIA 568B
22-38Y-21
These products are an acceptable choice for some LANs. However, home-run cabling and IDC style panels are preferred for
their higher performance characteristics. See HD Patch on page 30.
Page 40
UTP CLOSET SOLUTIONS
UTP Octopus
The UTP Octopus is used for system equipment with multiple connections. It consolidates individual 2, 4,
6 or 8-wire modular plugs to a 25-pair feeder cable. This eliminates the “rat’s nest syndrome” behind
system equipment. The standard product is two feet long with a 50-position male connector. 50-Position
female connectors and four or six-foot lengths are also available.
PART NO.
NO. OF WIRES
CHANNELS
POLARIZATION
8
6
6
8
WE8W
WE8W
8
6
WE8W
UTP Octopus
Shipping Weight:
6 Channel 8W 7oz. (198g)
8 Channel 6W 10oz. (283g)
12 Channel 4W 14oz. (397g)
EIA T568B/356A
23-206-811
23-208-811
EIA T568A
23-206-817
Cable Markers
Cable Markers are available in sequentially-numbered cards and are ideal for cable identification.
PART NO.
DESCRIPTION
35-251
35-252
35-253
Cable Markers - Sequential 1 to 33 (ea)
Cable Markers - Sequential 34 to 66 (ea)
Cable Markers - Sequential 67 to 99 (ea)
35-251, 35-252, 35-253
Cable Markers
Each numbered strip is adhesive-backed and
measures 25"W x 1.50"L (6mm x 38mm)
with individual numbers repeated the length of the strip.
Mod Plugs
Using a modular tool, Mod Plugs are crimped to modular cord or UTP to produce line cords and patch
cords. They are designed to accommodate stranded Mod Cord or 24-28 AWG UTP cable. Contacts are
plated with 50µ inches gold over 100µ inches nickel. Mod Plugs are packaged in bags of 100.
PART NO.
DESCRIPTION
02.B0010
Plugs WE8W Bulk (100 per bag)
02.B0010
Mod Plugs
Dimensions (ea): .37”H x .52”W x .46”D
(9.4mm x .52mm x .46mm)
Shipping Weight (Bag of 100): 6.0 oz. (170g)
A
C
B
Mod Plug Dimensions in Inches (MM)
Page 41
A
B
C
.37 (9.4)
.52 (13.2)
.46 (11.7)
UTP CLOSET SOLUTIONS
SLT3TM Tester
The Molex Premise Networks SLT3 Tester provides instant identification of most common voice and data
problems including shorts, opens, reversals and miswires.
The master and remote units separate for end-to-end testing of installed cabling. Problems are detected
within seconds — the continuously-sequencing LED display immediately alerts you to problems in the
cabling system. The units simply snap and lock together when not in use, making it easy to carry and
store. This also activates the auto-off feature to extend battery life.
33-100
SLT3 Tester
Dimensions (set): 5.75"H x 2.3"W x 1.5"D
(146mm x 58.4mm x 38.1mm)
Shipping Weight (set): 8 oz. (226g)
Designed to fit neatly into a tool box or pocket, the SLT3 tester also has a convenient ring for attaching to a
belt or frame. A durable nylon carry case may be purchased as an optional accessory. Frame adapters are
available for testing from punch down block to wallplate in one simple operation.
• Innovative 3-in-1 design features modular jacks for testing USOC, T568A and T568B cabling systems
• Accurately verifies the continuity and sequence of 1, 2, 3 and 4-pair voice and data channels
• Continuously-sequencing LED display provides diagnostic readout that detects shorts, opens,
reversals and miswires at a glance
• Master and remote units snap and lock together when not in use; jacks are protected
• Ergonomically designed hand-held unit is lightweight, rugged and impact-resistant
• 9 volt alkaline battery included
• Auto-off feature extends battery life
• Carry case and accessory kit available
DO NOT USE ON LIVE CIRCUITS
33-B0010
SLT3 Accessory Kit
Shipping Weight: 11 oz. (312g)
PART NO.
DESCRIPTION
33-100
33.B0020
33.B0010
SLT3 Tester with 9 Volt Battery
SLT3 Tester with Carry Case
SLT3 Accessory Kit – includes two 8-wire line cords, two frame adapters
(KATT-568B, and KATT 568A), and one Mod-Mod MMJ-USOC Adapter.
Does not include tester.
SLT3 Carry Case
33-100-P
Frame Adapters
The Frame Adapter, also known as a test shoe or block adapter, converts one channel on a distribution
frame block to a modular jack. These adapters allow the tester to test from the punch down block to the
wallplate in one simple operation.
36.0B.011.B0050, 36.0B.017.B0050
KATT Frame Adapter 568A/B
Dimensions: 7.5"L x 1.25"W x .625"H
(190mm x 31mm x 15mm)
Shipping Weight: 9oz. (255g)
PART NO.
DESCRIPTION
Frame Adapters
33-578
33-578-81
36.0B.011.B0050
AT&T 110 (USOC)
110 to 568B
KATT Frame Adapter 568B
Page 42
UTP CLOSET SOLUTIONS
IDC Punch Down Tools
Molex Premise Networks offers a variety of tooling for all your termination needs.
The Molex Premise Networks Punch Down Tools provide reliable terminations at a reasonable cost. Both the
Deluxe and Standard Punch Down Tools are compatible with KATT, 110 style and Krone IDC connectors.
Their low-impact force prevents damage to connectors.
PART NO.
DESCRIPTION
31-001
KPD-00056
KPD-00057
31-001-1
14-0401-001
Deluxe IDC Punch Down Tool
Standard IDC Punch Down Tool
110 Multi Pair Punch Down Tool
110 Replacement Blade
KATT Loading Tool
31-001
Deluxe Punch Down Tool
Dimensions: 6.5” (w/blade)
(165mm)
Shipping Weight: 6.0 oz. (170g)
KPD-00057
110 Multi Pair Punch Down Tool
Dimensions: 9”
(229mm)
Shipping Weight: 1lb. 2 oz.. (504g)
KPD-00056
Standard IDC Punch Down Tool
Dimensions: 7”
(178mm)
Shipping Weight: 4.5 oz. (126g)
14-0401-001
KATT Loading Tool
Dimensions: 3.5”
(88mm)
Shipping Weight: < 1 oz. (28g)
Page 43
Download