Green efficiency Oil-filled from 100 to 2500 kVA with insulation cl. <24 kV Losses Ao - Ak according to IEC EN 50464-1 To-PA A B GENERAL INFORMATION At present, the improvement of the energy efficiency cannot be considered a slogan anymore, but a need of our time. TO-PA series high efficiency transformers are created for this purpose guaranteeing: • savings in operating costs of the plant, due to low values of losses. • consumption reduction of energy resources. • reduction of CO2 emissions Ao Ak C D E ANNUAL SAVINGS MAXIMUM COMPARED TO TRANSFORMERS WITH NORMAL LOSSES RATED POWER kVA 50 100 160 250 400 630 800 1000 1250 1600 2000 2500 LOW CONSUMPTION MWh 7,3 12,7 19,2 26,7 37,9 52,5 58,3 64,2 67,9 86,7 112,6 128,3 LOW EMISSIONS CO2 TON 5,5 9,5 14,4 20,0 28,4 39,4 43,7 48,2 50,9 65,0 84,4 96,3 ENERGY SAVINGS TOE* 1,4 2,4 3,6 5,0 7,1 9,8 10,9 12,0 12,7 16,2 21,0 24,0 * TON OF OIL EQUIVALENT PARTICULARITIES OF AN OILFILLED TRANSFORMER • • • • The extreme flexibility of the heat reducing waves present on the transformer tank, allows to compensate the volume increases of the insulating fluid related to its operating temperature. The leak-proofness of the transformer tank prevents the absorption of humidity, making it “Maintenance free”. Reference Norms : CEI EN 60067-1 to 10 CEI EN 50464-1 The phases of design and building, in addition to their compliance with IEC EN norms, take into account the following rules: ISO 9001 : 2008 regarding the quality standards and procedures. ISO 14001 : 2004 regarding the environmental issues. MF TRASFORMATORI guarantees the use of PCB free insulating fluids free from PCB. The magnetic core is built of grain-oriented electrical steel sheets and they use the step lap technique for their cut and assembly to reduce the abnormal overheating risks and to decrease the noise. The coils are designed and built so that the transformer may operate on full-load conditions in strict compliance with A thermal class. Note: on request, we may provide transformers with the same electrical features but with a conservator. PROVIDED STANDARD ACCESSORIES DESCRIPTION • • • • • The oil-filled distribution transformers have the following features Cooling ONAN. They may be installed either inside or outside. Anti-corrosion surface treatment. Suitable for heavy working conditions. Tested according to IEC 60296 standards. Scheda MF_Trasformatori_Olio_EN.indd 1 • • • • • • • • Bushings for MV and LV connections. Primary voltage regulator with 5 positions installed on the tank. Rating plate. Lifting lugs. 2 Earthing points. 4 Bi-directional flat rollers. Filling valve. Drain valve according to IEC EN 50216-4. 24/03/14 11.06 Green efficiency FROM 100 TO 2500 KVA WITH INSULATION CL. 24 KV LOSSES Ao Ak ACCORDING TO IEC EN 504641 RATED POWER kVA NOLOAD LOSSES LOAD LOSSES AT 75 °C Oil-filled To-PA 50 90 750 100 145 1.250 160 210 1.700 250 300 2.350 400 430 3.250 630 560 4.800 800 650 6.000 1000 770 7.600 1250 950 9.500 1600 1.200 12.000 2000 1.450 15.000 2500 1.750 18.500 % % 1 4 11,6 0,9 4 10,6 0,6 4 10,10 0,6 4 9,2 0,6 4 9,4 0,6 6 9 0,6 6 8,4 0,6 6 8,4 0,6 6 8,8 0,4 6 8 0,4 6 7,6 0,4 6 7,5 OUTPUT AT 75°C COSφ 1 100% LOAD COSφ 1 75% LOAD COSφ 0,9 100% LOAD COSφ 0,9 75% LOAD % % % % 98,35 98,65 98,17 98,51 98,62 98,88 98,47 98,76 98,82 99,04 98,69 98,93 98,95 99,14 98,84 99,05 99,09 99,25 98,99 99,17 99,16 99,31 99,06 99,24 99,18 99,33 99,08 99,26 99,18 99,33 99,08 99,26 99,18 99,33 99,08 99,26 99,18 99,34 99,09 99,27 99,18 99,34 99,09 99,27 99,20 99,36 99,11 99,28 VOLTAGE DROP AT 75° C COSφ 1 100% LOAD COSφ 0,9 100% LOAD % % 1,57 3,00 1,32 2,82 1,14 2,68 1,02 2,59 0,89 2,49 0,94 3,41 0,93 3,4 0,93 3,4 0,93 3,4 0,93 3,4 0,93 3,4 0,92 3,39 NOISE SOUND POWER LEVEL Lwa dB(A) 39 41 44 47 50 52 53 55 56 58 60 63 NOLOAD CURRENT Io SHORT CIRCUIT VOLTAGE VCC INPUT CURRENT IE/IN W W SIZES AND WEIGHTS APPROXIMATE C Transformer with conservator C Hermetically Sealed Transformer D A D B D D B A HERMETICALLY SEALED TRANSFORMER LENGTH A mm DEPTH B mm HEIGHT C mm WHEEL INTERAXIS D mm WHEEL DIAMETER mm OIL WEIGHT kg TOTAL WEIGHT kg 50 1.000 600 1.425 400 150 150 710 100 1.000 600 1.425 520 150 170 800 160 1.050 600 1.425 520 150 210 1.025 250 1.150 600 1.425 520 150 260 1.300 400 1.250 600 1.425 670 150 330 1.625 630 1.600 900 1.500 670 150 510 2.300 800 1.750 1.000 1.600 820 150 650 3.000 1000 1.750 1.000 1.600 820 150 670 3.150 1250 1.850 1.100 1.600 820 150 670 3.250 1600 1.900 1.100 1.700 820 150 810 4.150 2000 2.200 1.200 2.050 1.000 150 1.050 5.200 2500 2.250 1.300 2.250 1.000 150 1.200 5.850 TRANSFORMER WITH CONSERVATOR LENGTH A DEPTH B HEIGHT C WHEEL INTERAXIS D WHEEL DIAMETER OIL WEIGHT TOTAL WEIGHT 50 1.000 600 1.525 400 150 150 715 100 1.000 600 1.525 520 150 170 810 160 1.050 600 1.505 520 150 210 1.045 250 1.150 600 1.545 520 150 260 1.325 400 1.250 600 1.525 670 150 340 1.650 630 1.600 900 1.600 670 150 530 2.325 800 1.750 1.000 1.820 820 150 670 3.025 1000 1.750 1.000 1.920 820 150 690 3.175 1250 1.850 1.100 1.800 820 150 690 3.285 1600 1.900 1.100 1.900 820 150 830 4.190 2000 2.200 1.200 2.250 1.000 150 1.070 5.250 2500 2.250 1.300 2.400 1.000 150 1.250 5.900 mm mm mm mm mm kg kg LOC. S. ANNA 22/24 25011 CALCINATO BRESCIA ITALY TEL. +39 030 9636020028596 FAX +39 030 9980218 www.mftrasformatori.it - info@mftrasformatori.it Scheda MF_Trasformatori_Olio_EN.indd 2 21/03/14 13.19 Green efficiency Oil-filled from 100 to 2500 kVA with insulation cl. < 24 kV Losses Bo - Ak according to IEC EN 50464-1 To-PB A B GENERAL INFORMATION At present, the improvement of the energy efficiency cannot be considered a slogan anymore, but a need of our time. TO-PB series high efficiency transformers are created for this purpose guaranteeing: • savings in operating costs of the plant, due to low values of losses. • consumption reduction of energy resources. • reduction of CO2 emissions Bo Ak C D E ANNUAL SAVINGS MAXIMUM COMPARED TO TRANSFORMERS WITH NORMAL LOSSES RATED POWER kVA 50 100 160 250 400 630 800 1000 1250 1600 2000 2500 LOW CONSUMPTION MWh 7,2 12,4 18,7 26,2 37,1 51,4 56,9 62,7 66,1 84,5 109,5 124,8 LOW EMISSIONS CO2 TON 5,4 9,3 14,1 19,6 27,9 38,6 42,7 47,0 49,6 63,4 82,1 93,6 ENERGY SAVINGS TOE* 1,4 2,3 3,5 4,9 6,9 9,6 10,6 11,7 12,4 15,8 20,5 23,3 * TON OF OIL EQUIVALENT PARTICULARITIES OF AN OILFILLED TRANSFORMER • • • • The extreme flexibility of the heat reducing waves present on the transformer tank, allows to compensate the volume increases of the insulating fluid related to its operating temperature. The leak-proofness of the transformer tank prevents the absorption of humidity, making it “Maintenance free”. Reference Norms : CEI EN 60067-1 to 10 CEI EN 50464-1 The phases of design and building, in addition to their compliance with IEC EN norms, take into account the following rules: ISO 9001 : 2008 regarding the quality standards and procedures. ISO 14001 : 2004 regarding the environmental issues. MF TRASFORMATORI guarantees the use of PCB free insulating fluids. The magnetic core is built of grain-oriented electrical steel sheets and they use the step lap technique for their cut and assembly to reduce the abnormal overheating risks and to decrease the noise. The coils are designed and built so that the transformer may operate on full-load conditions in strict compliance with A thermal class. Note: on request, we may provide transformers with the same electrical features but with a conservator. PROVIDED STANDARD ACCESSORIES DESCRIPTION • • • • • The oil-filled distribution transformers have the following features Cooling ONAN. They may be installed either inside or outside. Anti-corrosion surface treatment. Suitable for heavy working conditions. Tested according to IEC 60296 standards. Scheda MF_Trasformatori_Olio_EN.indd 3 • • • • • • • • Bushings for MV and LV connections. Primary voltage regulator with 5 positions installed on the tank. Rating plate. Lifting lugs. 2 Earthing points. 4 Bi-directional flat rollers. Filling valve. Drain valve according to IEC EN 50216-4. 21/03/14 13.19 Green efficiency FROM 100 TO 2500 KVA WITH INSULATION CL. 24 KV LOSSES Bo Ak ACCORDING TO IEC EN 504641 RATED POWER kVA NOLOAD LOSSES LOAD LOSSES AT 75 °C Oil-filled To-PB 50 110 750 100 180 1.250 160 260 1.700 250 360 2.350 400 520 3.250 630 680 4.800 800 800 6.000 1000 940 7.600 1250 1.150 9.500 1600 1.450 12.000 2000 1.800 15.000 2500 2.150 18.500 % % 1 4 11,6 0,9 4 10,6 0,6 4 10,10 0,6 4 9,2 0,6 4 9,4 0,6 6 9 0,6 6 8,4 0,6 6 8,4 0,6 6 8,8 0,4 6 8 0,4 6 7,6 0,4 6 7,5 OUTPUT AT 75°C COSφ 1 100% LOAD COSφ 1 75% LOAD COSφ 0,9 100% LOAD COSφ 0,9 75% LOAD % % % % 98,31 98,60 98,12 98,45 98,59 98,84 99,44 98,71 98,79 99,00 98,66 98,89 98,93 99,11 98,81 99,01 99,07 99,22 98,96 99,14 99,14 99,29 99,04 99,21 99,16 99,31 99,06 99,23 99,16 99,31 99,06 99,23 99,16 99,31 99,06 99,23 99,17 99,32 99,07 99,25 99,17 99,32 99,07 99,25 99,18 99,33 99,09 99,26 VOLTAGE DROP AT 75° C COSφ 1 100% LOAD COSφ 0,9 100% LOAD % % 1,57 3,00 1,32 2,82 1,14 2,68 1,02 2,59 0,89 2,49 0,94 3,41 0,93 3,4 0,93 3,4 0,93 3,4 0,93 3,4 0,93 3,4 0,92 3,39 NOISE SOUND POWER LEVEL Lwa dB(A) 42 44 47 50 53 55 56 58 59 61 63 66 NOLOAD CURRENT Io SHORT CIRCUIT VOLTAGE Vcc INPUT CURRENT IE/IN W W SIZES AND WEIGHTS APPROXIMATE C Transformer with conservator C Hermetically Sealed Transformer D A D B D D B A HERMETICALLY SEALED TRANSFORMER LENGTH A mm DEPTH B mm HEIGHT C mm WHEEL INTERAXIS D mm WHEEL DIAMETER mm OIL WEIGHT kg TOTAL WEIGHT kg 50 950 530 1.250 400 150 110 570 100 1.000 600 1.425 520 150 170 800 160 1.050 600 1.425 520 150 210 1.025 250 1.150 600 1.425 520 150 260 1.300 400 1.250 600 1.425 670 150 330 1.625 630 1.600 900 1.500 670 150 510 2.300 800 1.750 1.000 1.500 820 150 600 3.000 1000 1.750 1.000 1.600 820 150 670 3.150 1250 1.850 1.100 1.600 820 150 670 3.250 1600 1.900 1.100 1.700 820 150 810 4.150 2000 2.200 1.200 2.050 1.000 150 1.050 5.200 2500 2.250 1.300 2.250 1.000 150 1.200 5.850 TRANSFORMER WITH CONSERVATOR LENGTH A DEPTH B HEIGHT C WHEEL INTERAXIS D WHEEL DIAMETER OIL WEIGHT TOTAL WEIGHT 50 950 530 1.350 400 150 110 575 100 1.000 600 1.525 520 150 175 810 160 1.050 600 1.505 520 150 215 1.040 250 1.150 600 1.545 520 150 270 1.320 400 1.250 600 1.525 670 150 340 1.645 630 1.600 900 1.600 670 150 525 2.320 800 1.750 1.000 1.720 820 150 625 3.020 1000 1.750 1.000 1.920 820 150 700 3.175 1250 1.850 1.100 1.800 820 150 700 3.275 1600 1.900 1.100 1.900 820 150 840 4.180 2000 2.200 1.200 2.250 1.000 150 1.090 5.250 2500 2.250 1.300 2.400 1.000 150 1.250 5.900 mm mm mm mm mm kg kg LOC. S. ANNA 22/24 25011 CALCINATO BRESCIA ITALY TEL. +39 030 9636020028596 FAX +39 030 9980218 www.mftrasformatori.it - info@mftrasformatori.it Scheda MF_Trasformatori_Olio_EN.indd 4 21/03/14 13.19 Green efficiency Oil-filled from 100 to 2500 kVA with insulation cl. < 24 kV Losses Bo-Bk according to IEC EN 50464-1 TR-PC A B GENERAL INFORMATION At present, the improvement of the energy efficiency cannot be considered a slogan anymore, but a need of our time. TO-PC series high efficiency transformers are created for this purpose guaranteeing: • savings in operating costs of the plant, due to low values of losses. • consumption reduction of energy resources. • reduction of CO2 emissions C D Bo Bk E ANNUAL SAVINGS MAXIMUM COMPARED TO TRANSFORMERS WITH NORMAL LOSSES RATED POWER kVA 50 100 160 250 400 630 800 1000 1250 1600 2000 2500 LOW CONSUMPTION MWh 6,2 10,4 16,1 22,7 31,9 44,4 48,2 50,5 53,0 67,0 83,2 94,2 LOW EMISSIONS CO2 TON 4,6 7,8 12,1 17,0 23,9 33,3 36,1 37,8 39,7 50,3 62,4 70,6 ENERGY SAVINGS TOE* 1,2 1,9 3,0 4,2 6,0 8,3 9,0 9,4 9,9 12,5 15,6 17,6 * TON OF OIL EQUIVALENT PARTICULARITIES OF AN OILFILLED TRANSFORMER • • • • The extreme flexibility of the heat reducing waves present on the transformer tank, allows to compensate the volume increases of the insulating fluid related to its operating temperature. The leak-proofness of the transformer tank prevents the absorption of humidity, making it “Maintenance free”. Reference Norms : CEI EN 60067-1 to 10 CEI EN 50464-1 The phases of design and building, in addition to their compliance with IEC EN norms, take into account the following rules: ISO 9001 : 2008 regarding the quality standards and procedures. ISO 14001 : 2004 regarding the environmental issues. MF TRASFORMATORI guarantees the use of PCB free insulating fluids. The magnetic core is built of grain-oriented electrical steel sheets and they use the step lap technique for their cut and assembly to reduce the abnormal overheating risks and to decrease the noise. The coils are designed and built so that the transformer may operate on full-load conditions in strict compliance with A thermal class. Note: on request, we may provide transformers with the same electrical features but with a conservator. PROVIDED STANDARD ACCESSORIES DESCRIPTION • • • • • The oil-filled distribution transformers have the following features Cooling ONAN. They may be installed either inside or outside. Anti-corrosion surface treatment. Suitable for heavy working conditions. Tested according to IEC 60296 standards. Scheda MF_Trasformatori_Olio_EN.indd 5 • • • • • • • • Bushings for MV and LV connections. Primary voltage regulator with 5 positions installed on the tank. Rating plate. Lifting lugs. 2 Earthing points. 4 Bi-directional flat rollers. Filling valve. Drain valve according to IEC EN 50216-4. 21/03/14 13.19 Green efficiency FROM 100 TO 2500 KVA WITH INSULATION CL. 24 KV LOSSES Bo Bk ACCORDING TO IEC EN 504641 RATED POWER kVA NOLOAD LOSSES LOAD LOSSES AT 75 °C Oil-filled To-PC 50 110 875 100 180 1.475 160 260 2.000 250 360 2.750 400 520 3.850 630 680 5.600 800 800 7.000 1000 940 9.000 1250 1.150 11.000 1600 1.450 14.000 2000 1.800 18.000 2500 2.150 22.000 % % 1 4 11,6 0,9 4 10,6 0,6 4 10,10 0,6 4 9,2 0,6 4 9,4 0,6 6 9 0,6 6 8,4 0,6 6 8,4 0,6 6 8,8 0,4 6 8 0,4 6 7,6 0,4 6 7,5 OUTPUT AT 75°C COSφ 1 100% LOAD COSφ 1 75% LOAD COSφ 0,9 100% LOAD COSφ 0,9 75% LOAD % % % % 98,07 98,22 97,86 98,25 98,37 98,67 98,19 98,53 98,61 98,86 98,45 98,73 98,77 98,99 98,64 98,88 98,92 99,11 98,80 99,02 99,01 99,20 98,90 99,11 99,03 99,22 98,93 99,13 99,02 99,21 98,91 99,12 99,04 99,12 98,93 99,14 99,04 99,22 98,94 99,14 99,02 99,21 98,91 99,12 99,04 99,23 98,94 99,15 VOLTAGE DROP AT 75° C COSφ 1 100% LOAD COSφ 0,9 100% LOAD % % 1,81 3,17 1,54 2,98 1,32 2,82 1,17 2,71 1,04 2,61 1,06 3,51 1,05 3,5 1,08 3,52 1,05 3,5 1,05 3,5 1,08 3,52 1,06 3,50 NOISE SOUND POWER LEVEL Lwa dB(A) 42 44 47 50 53 55 56 58 59 61 63 66 NOLOAD CURRENT Io SHORT CIRCUIT VOLTAGE Vcc INPUT CURRENT IE/IN W W SIZES AND WEIGHTS APPROXIMATE C Transformer with conservator C Hermetically Sealed Transformer D A D B D D B A HERMETICALLY SEALED TRANSFORMER LENGTH A mm DEPTH B mm HEIGHT C mm WHEEL INTERAXIS D mm WHEEL DIAMETER mm OIL WEIGHT kg TOTAL WEIGHT kg 50 850 530 1.250 400 150 110 550 100 950 600 1.425 520 150 140 720 160 1.050 600 1.425 520 150 180 825 250 1.150 700 1.425 520 150 240 1.175 400 1.250 700 1.425 670 150 300 1.475 630 1.600 900 1.500 670 150 470 2.100 800 1.650 1.000 1.500 820 150 550 2.500 1000 1.700 1.000 1.500 820 150 570 2.750 1250 1.750 1.100 1.600 820 150 610 3.000 1600 1.850 1.100 1.600 820 150 750 3.700 2000 2.350 1.200 1.950 1.000 150 940 4.650 2500 2.200 1.300 2.100 1.000 150 1.110 5.300 TRANSFORMER WITH CONSERVATOR LENGTH A DEPTH B HEIGHT C WHEEL INTERAXIS D WHEEL DIAMETER OIL WEIGHT TOTAL WEIGHT 50 950 530 1.350 400 150 115 555 100 1.000 600 1.525 520 150 145 730 160 1.050 600 1.505 520 150 185 840 250 1.150 600 1.545 520 150 250 1.190 400 1.250 600 1.525 670 150 310 1.495 630 1.600 900 1.600 670 150 480 2.120 800 1.750 1.000 1.720 820 150 560 2.520 1000 1.750 1.000 1.820 820 150 585 2.780 1250 1.850 1.100 1.800 820 150 625 3.030 1600 1.900 1.100 1.800 820 150 775 3.730 2000 2.200 1.200 2.150 1.000 150 970 5.700 2500 2.250 1.300 2.250 1.000 150 1.140 5.350 mm mm mm mm mm kg kg LOC. S. ANNA 22/24 25011 CALCINATO BRESCIA ITALY TEL. +39 030 9636020028596 FAX +39 030 9980218 www.mftrasformatori.it - info@mftrasformatori.it Scheda MF_Trasformatori_Olio_EN.indd 6 21/03/14 13.19 Oil-filled from 100 to 2500 kVA with insulation cl.< 24 kV Losses Eo - Bk according to IEC EN 50464-1 To-PD A B GENERAL INFORMATION At present, the improvement of the energy efficiency cannot be considered a slogan anymore, but a need of our time. TO-PD series high efficiency transformers are created for this purpose guaranteeing: • savings in operating costs of the plant, due to low values of losses. • consumption reduction of energy resources. • reduction of CO2 emissions C D Eo Bk E ANNUAL SAVINGS MAXIMUM COMPARED TO TRANSFORMERS WITH NORMAL LOSSES RATED POWER kVA 50 100 160 250 400 630 800 1000 1250 1600 2000 2500 LOW CONSUMPTION MWh 5,5 9,2 14,4 20,1 28,3 39,9 42,9 43,8 44,7 56,9 72,8 82,3 LOW EMISSIONS CO2 TON 4,1 6,9 10,8 15,1 21,2 29,9 32,2 32,9 33,5 42,7 54,6 61,8 ENERGY SAVINGS TOE* 1,0 1,7 2,7 3,8 5,3 7,5 8,0 8,2 8,4 10,6 13,6 15,4 * TON OF OIL EQUIVALENT PARTICULARITIES OF AN OILFILLED TRANSFORMER • • • • The extreme flexibility of the heat reducing waves present on the transformer tank, allows to compensate the volume increases of the insulating fluid related to its operating temperature. The leak-proofness of the transformer tank prevents the absorption of humidity, making it “Maintenance free”. Reference Norms : CEI EN 60067-1 to 10 CEI EN 50464-1 The phases of design and building, in addition to their compliance with IEC EN norms, take into account the following rules: ISO 9001 : 2008 regarding the quality standards and procedures. ISO 14001 : 2004 regarding the environmental issues. MF TRASFORMATORI guarantees the use of PCB free insulating fluids. The magnetic core is built of grain-oriented electrical steel sheets and they use the step lap technique for their cut and assembly to reduce the abnormal overheating risks and to decrease the noise. The coils are designed and built so that the transformer may operate on full-load conditions in strict compliance with A thermal class. Note: on request, we may provide transformers with the same electrical features but with a conservator. PROVIDED STANDARD ACCESSORIES DESCRIPTION • • • • • The oil-filled distribution transformers have the following features Cooling ONAN. They may be installed either inside or outside. Anti-corrosion surface treatment. Suitable for heavy working conditions. Tested according to IEC 60296 standards. Scheda MF_Trasformatori_Olio_EN.indd 7 • • • • • • • • Bushings for MV and LV connections. Primary voltage regulator with 5 positions installed on the tank. Rating plate. Lifting lugs. 2 Earthing points. 4 Bi-directional flat rollers. Filling valve. Drain valve according to IEC EN 50216-4. 21/03/14 13.19 FROM 100 TO 2500 KVA WITH INSULATION CL. 24 KV LOSSES Eo Bk ACCORDING TO IEC EN 504641 RATED POWER kVA NOLOAD LOSSES LOAD LOSSES AT 75 °C Oil-filled To-PD 50 190 875 100 320 1.475 160 460 2.000 250 650 2.750 400 930 3.850 630 1.200 5.600 800 1.400 7.000 1000 1.700 9.000 1250 2.100 11.000 1600 2.600 14.000 2000 3.100 18.000 2500 3.500 22.000 % % 1 4 11,6 0,9 4 10,6 0,6 4 10,10 0,6 4 9,2 0,6 4 9,4 0,6 6 9 0,6 6 8,4 0,6 6 8,4 0,6 6 8,8 0,4 6 8 0,4 6 7,6 0,4 6 7,5 OUTPUT AT 75°C COSφ 1 100% LOAD COSφ 1 75% LOAD COSφ 0,9 100% LOAD COSφ 0,9 75% LOAD % % % % 97,91 98,21 97,69 98,02 98,24 98,49 98,04 98,33 98,49 98,70 98,32 98,55 98,66 98,84 98,51 98,71 98,82 98,98 98,69 98,87 98,93 99,09 98,81 98,99 98,96 99,12 98,85 99,02 98,94 99,11 98,83 99,01 98,96 99,12 98,85 99,03 98,97 99,13 98,83 99,02 98,96 99,13 98,84 99,03 98,99 99,16 98,88 99,07 VOLTAGE DROP AT 75° C COSφ 1 100% LOAD COSφ 0,9 100% LOAD % % 1,81 3,17 1,54 2,98 1,32 2,82 1,17 2,71 1,04 2,61 1,06 3,51 1,05 3,5 1,08 3,52 1,05 3,5 1,05 3,5 1,08 3,52 1,06 3,50 NOISE SOUND POWER LEVEL Lwa dB(A) 55 59 62 65 68 70 71 73 74 76 78 81 NOLOAD CURRENT Io SHORT CIRCUIT VOLTAGE VCC INPUT CURRENT IE/IN W W SIZES AND WEIGHTS APPROXIMATE C Transformer with conservator C Hermetically Sealed Transformer D A D B HERMETICALLY SEALED TRANSFORMER LENGTH A mm DEPTH B mm HEIGHT C mm WHEEL INTERAXIS D mm WHEEL DIAMETER mm OIL WEIGHT kg TOTAL WEIGHT kg TRANSFORMER WITH CONSERVATOR LENGTH A DEPTH B HEIGHT C WHEEL INTERAXIS D WHEEL DIAMETER OIL WEIGHT TOTAL WEIGHT mm mm mm mm mm kg kg D D B A 50 850 500 900 400 150 90 460 100 1.000 600 900 520 150 130 585 160 1.050 600 1.000 520 150 170 750 250 1.150 700 1.200 520 150 230 1.100 400 1.250 700 1.300 670 150 270 1.375 630 1.550 900 1.400 670 150 430 1.910 800 1.600 900 1.500 820 150 520 2.300 1000 1.700 1.000 1.500 820 150 580 2.600 1250 1.800 1.100 1.500 820 150 610 2.900 1600 1.900 1.200 1.600 820 150 730 3.650 2000 2.100 1.200 1.900 1.000 150 930 4.300 2500 2.200 1.200 1.950 1.000 150 1.000 5.100 50 850 500 1.000 400 150 90 465 100 1.000 600 1.000 520 150 130 595 160 1.050 600 1.080 520 150 170 765 250 1.150 700 1.320 520 150 240 1.115 400 1.250 700 1.400 670 150 280 1.395 630 1.550 900 1.500 670 150 440 1.930 800 1.600 900 1.720 820 150 530 2.320 1000 1.700 1.000 1.820 820 150 590 2.620 1250 1.800 1.100 1.700 820 150 625 2.930 1600 1.900 1.200 1.800 820 150 745 3.680 2000 2.100 1.200 2.100 1.000 150 950 4.350 2500 2.200 1.200 2.100 1.000 150 1.020 5.100 LOC. S. ANNA 22/24 25011 CALCINATO BRESCIA ITALY TEL. +39 030 9636020028596 FAX +39 030 9980218 www.mftrasformatori.it - info@mftrasformatori.it Scheda MF_Trasformatori_Olio_EN.indd 8 21/03/14 13.19 Oil-filled from 100 to 2500 kVA with insulation cl. < 24 kV Losses Eo - Dk according to IEC EN 50464-1 TO-PE A B GENERAL INFORMATION The regulations push more and more the efficiency improvement. The products offered to our customers allow energy savings and comply with the new product regulations. All this leads to higher performance transformers allowing our customers to obtain: • Plants management cost savings due to low values of losses. • Energy resources consumption reduction. C D E RATED POWER kVA OUTPUT AT 75°C Eo Dk 50 100 160 250 400 630 800 1000 1250 1600 2000 2500 COSφ 1 100% LOAD 97,01 97,59 97,82 98,10 98,30 98,45 98,53 98,55 98,57 98,62 98,57 98,60 COSφ 1 50% LOAD 97,93 98,31 98,48 98,66 98,80 98,94 99,00 99,02 99,03 99,06 99,05 99,09 PARTICULARITIES OF AN OILFILLED TRANSFORMER • • • • The extreme flexibility of the heat reducing waves present on the transformer tank, allows to compensate the volume increases of the insulating fluid related to its operating temperature. The leak-proofness of the transformer tank prevents the absorption of humidity, making it “Maintenance free”. Reference Norms : CEI EN 60067-1 to 10 CEI EN 50464-1 The phases of design and building, in addition to their compliance with IEC EN norms, take into account the following rules: ISO 9001 : 2008 regarding the quality standards and procedures. ISO 14001 : 2004 regarding the environmental issues. MF TRASFORMATORI guarantees the use of insulating fl uids free from PCB. The magnetic core is built of grain-oriented electrical steel sheets and they use the step lap technique for their cut and assembly to reduce the abnormal overheating risks and to decrease the noise. The coils are designed and built so that the transformer may operate on full-load conditions in strict compliance with A thermal class. Note: on request, we may provide transformers with the same electrical features but with a conservator. PROVIDED STANDARD ACCESSORIES DESCRIPTION • • • • • The oil-filled distribution transformers have the following features Cooling ONAN. They may be installed either inside or outside. Anti-corrosion surface treatment. Suitable for heavy working conditions. Tested according to IEC 60296 standards. Scheda MF_Trasformatori_Olio_EN.indd 9 • • • • • • • • Bushings for MV and LV connections. Primary voltage regulator with 5 positions installed on the tank. Rating plate. Lifting lugs. 2 Earthing points. 4 Bi-directional flat rollers. Filling valve. Drain valve according to IEC EN 50216-4. 21/03/14 13.19 FROM 100 TO 2500 KVA WITH INSULATION CL. 24 KV LOSSES Eo Dk ACCORDING TO IEC EN 504641 RATED POWER kVA NOLOAD LOSSES LOAD LOSSES AT 75 °C Oil-filled To-Pe 50 190 1.350 100 320 2.150 160 460 3.100 250 650 4.200 400 930 6.000 630 1.200 8.700 800 1.400 10.500 1000 1.700 13.000 1250 2.100 16.000 1600 2.600 20.000 2000 3.100 26.000 2500 3.500 32.000 % % 1 4 11,6 0,9 4 10,6 0,6 4 10,10 0,6 4 9,2 0,6 4 9,4 0,6 6 9 0,6 6 8,4 0,6 6 8,4 0,6 6 8,8 0,4 6 8 0,4 6 7,6 0,4 6 7,5 OUTPUT AT 75°C COSφ 1 100% LOAD COSφ 1 75% LOAD COSφ 0,9 100% LOAD COSφ 0,9 75% LOAD % % % % 97,01 97,53 96,69 97,26 97,59 98,00 97,33 97,78 97,82 98,20 97,59 98,00 98,10 98,42 97,89 98,25 98,30 98,59 98,11 98,43 98,45 98,73 98,28 98,59 98,53 98,80 98,37 98,67 98,55 98,81 98,39 98,68 98,57 98,83 98,42 98,70 98,62 98,86 98,45 98,73 98,57 98,83 98,41 98,70 98,60 98,87 98,45 98,74 VOLTAGE DROP AT 75° C COSφ 1 100% LOAD COSφ 0,9 100% LOAD % % 2,74 3,73 2,21 3,43 2,00 3,30 1,75 3,13 1,37 3 1,55 3,9 1,48 3,84 1,47 3,83 1,45 3,82 1,42 3,8 1,47 3,83 1,45 3,82 NOISE SOUND POWER LEVEL Lwa dB(A) 55 59 62 65 68 70 71 73 74 76 78 81 NOLOAD CURRENT Io SHORT CIRCUIT VOLTAGE VCC INPUT CURRENT IE/IN W W SIZES AND WEIGHTS APPROXIMATE C Transformer with conservator C Hermetically Sealed Transformer D A D B D D B A HERMETICALLY SEALED TRANSFORMER LENGTH A mm DEPTH B mm HEIGHT C mm WHEEL INTERAXIS D mm WHEEL DIAMETER mm OIL WEIGHT kg TOTAL WEIGHT kg 50 850 500 800 400 150 80 400 100 900 600 900 520 150 110 500 160 1.000 600 1.000 520 150 140 650 250 1.100 700 1.100 520 150 200 910 400 1.250 800 1.200 670 150 240 1.200 630 1.500 900 1.300 670 150 370 1.625 800 1.550 900 1.300 820 150 410 1.850 1000 1.650 1.000 1.400 820 150 480 2.250 1250 1.800 1.100 1.400 820 150 560 2.550 1600 1.850 1.100 1.500 820 150 650 3.150 2000 2.100 1.200 1.800 1.000 150 810 3.750 2500 2.150 1.300 1.850 1.000 150 860 4.300 TRANSFORMER WITH CONSERVATOR LENGTH A DEPTH B HEIGHT C WHEEL INTERAXIS D WHEEL DIAMETER OIL WEIGHT TOTAL WEIGHT 50 850 500 900 400 150 85 405 100 900 600 1.000 520 150 115 510 160 1.000 600 1.080 520 150 145 660 250 1.100 700 1.220 520 150 205 920 400 1.250 800 1.300 670 150 240 1.220 630 1.500 900 1.400 670 150 380 1.650 800 1.550 900 1.520 820 150 420 1.875 1000 1.650 1.000 1.720 820 150 495 2.275 1250 1.800 1.100 1.600 820 150 575 2.580 1600 1.850 1.100 1.700 820 150 675 3.180 2000 2.100 1.200 2.000 1.000 150 835 3.800 2500 2.150 1.300 2.000 1.000 150 885 4.350 mm mm mm mm mm kg kg LOC. S. ANNA 22/24 25011 CALCINATO BRESCIA ITALY TEL. +39 030 9636020028596 FAX +39 030 9980218 www.mftrasformatori.it - info@mftrasformatori.it Scheda MF_Trasformatori_Olio_EN.indd 10 21/03/14 13.19