FOR CURRENT INFORMATION
Horizontal Ganged Meter Sockets
•
1Ø, 600 Vac max., main lugs only, 2 through 6 meter positions, with and without
horn or lever bypass, end or center feed, overhead and underground service feeds
10 kA short circuit current rating (or higher with utility approval)
UL Listed, NEMA 3R enclosure
Supplied with ground lugs
Supplied with hub opening in top endwall, requires the use of a bolt-on hub, or closing plate
•
•
•
•
This metering is generally utility specific. Always check with local utility company before installing. Contact
your nearest Field Sales Office for additional catalog numbers, if required by utility.
Ringless Type, 1Ø3W, 600 Vac Max., Without Bypass or Jaw Release
Branch Ratings
Socket Service
No. of
Amperesc Positions
Jaw
Type
Qty.b
2
3
100 A
4
4
OH/UG
5
6
2
4
200 A
5
4
OH/UG
6
a
b
c
Mains
Rating
(A)
Cat. No.
200
205
205
250
300
205
360
UT2R1121B
UT3R1121B
UT4R1131B
UT5R1131B
UT6R1131B
UT2R2122B
UT4R2352T
302.00
373.00
440.00
605.00
771.00
431.00
737.00
500
UT5R2392TU
922.00
620
UT6R2392TU 1032.00
$ Price
Top Endwalla
Main Lugs
Branch Lugs
Phase & Neutral Phase
Box No.
& Neutral Hub Type Closing Plate See
Al/Cu
Page 2-4
(Order
(Order
Al/Cu (AWG)
(AWG/kcmil)
Separately) Separately)
6–250
13R
6–250
13R1
6–350
8–2/0
Series A
ACP
14R
6–350
15R
6–350
16R
6–250
Series A
ACP
17R
1/0–500
Series A-L
ACPL
18R
1/0–500 or
8–250
Series A-L
ACPL
19R
(2)1/0–350
1/0–500 or
Series A-L
ACPL
20R
(2)1/0–350
For Hubs and Closing Plates, see Accessories table below.
Fifth Jaw Kit available to convert 4-Jaw Socket to a 5-Jaw Socket. See Accessories table below.
Rating is continuous.
Meter Mains with Test Block Bypass (Meets EUSERC Requirements)
Table 2.3:
Ring Type, 1Ø3W and 3Ø4W, Meter Main with Test Block Bypass (Meets EUSERC Requirements)
Supplied with bondable neutral, suitable for use as service equipment. Suitable for overhead or underground service. UL Listed File E6294.
EMT3225CB
d
e
f
g
System (Incoming)
Meter Ampere Short Circuit
Main Circuit Breaker Type
and
Socket Rating Current
Cat. No.f
$ Price
Rating
(Order Separately)d
Service (Outgoing)
Type
(Max.)
120/240 Vac 1Ø3W
5-Jaw
225 A
100 kA max.
EMT1225CB
2730.00
2P Type QB, QD, QG, QJ, QOe, QO-VHe or QOHe
208Y/120 Vac 3Ø4Wg
or
7-Jaw
225 A
65 kA max.
EMT3225CB
3570.00
3P Type QB, QD, QG or QJ
240/120 Vac 3Ø4W Delta
Refer to page 2-15 to select main circuit breaker.
Requires use of EZM125QOA adapter (order separately), when using QO (40 A–125 A, 2-pole) 10kA max. SCCR, QO-VH (40 A–60 A, 2-pole) 22kA
max. SCCR, or QOH (40 A–60 A, 2-pole) 42kA max. SCCR. Refer to page 2-15 for pricing.
Refer to page 2-4 for box dimensions.
100 kA max.
Table 2.4:
METERING EQUIPMENT
Table 2.2:
2
UT2R1121B
EMT Terminal Wire Size h
Line Phase Lug
Line Neutral Lug
Service Ground Lug
6 AWG–300 kcmil Al/Cu 6 AWG–350 kcmil Al/Cu 4 AWG–300 kcmil Al/Cu
h
Refer to circuit breaker listings for usable load lug wire sizes.
Equipment Ground Lug
6 AWG–300 kcmil Al/Cu
Load Neutral Lug
4 AWG–300 kcmil Al/Cu
Meter Socket Accessories
Table 2.5:
Meter Socket Accessories
Accessory
EMT3225CB
Without Covers
Fifth Jaw Kit
Closing Plates
(to seal hub openings)
Series A
Hubs
(listed by conduit size)
Series A-L
Series B
Adapter Plate
Lug Kits
Sealing Ring
i
© 2007 Schneider Electric
All Rights Reserved
Description
Cat. No.
Converts a 4-jaw meter socket to a 5-jaw meter socket.
A5J
For use on meter sockets supplied without lever bypass or jaw release only.
For Series A (steel)
ACP
For Series A (aluminum)
ACPA
For Series A-L (steel)
ACPL
For Series A-L (aluminum)
ACPLA
1.00 inch
A100
1.25 inch
A125
1.50 inch
A150
2.00 inch
A200
2.50 inch
A250
2.00 inch
A200L
2.50 inch
A250L
3.00 inch
A300L
3.50 inch
A350L
4.00 inch
A400L
3.00 inch
B300i
To allow the use of a Series A Hub on a device that is setup for a series A-L Hub.
AAP
For use on meter sockets supplied with Line, Load, and Neutral Studs only. Be sure
to order enough lugs for each device (a typical 1Ø device requires 6 lugs).
Includes one, two-barrel lug (6-250 kcmil)
ARP00118
Includes one, single barrel lug (4-600 kcmil)
ARP00129
Includes three, two-barrel lugs (6-350 kcmil)
ARP00427
Snap-on Aluminum (Standard)
2920910001
Snap-on Stainless Steel (Non-standard)
ARP00026
Screw Type Aluminum (Non-standard)
29008W
$ Price
9.90
8.90
7.90
12.20
11.00
22.60
22.60
22.60
31.90
40.40
55.00
58.00
74.00
76.00
79.00
124.00
22.50
25.40
36.80
90.00
5.30
11.10
13.40
DE1A Discount.
DE4
DE1A
Discount
Schedule
2-3
Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com
Meter Sockets
Dimensions
Class 4131
www.us.schneider-electric.com
FOR CURRENT INFORMATION
D
W
Hub
Opening
Meter
Socket
W
D
Solid
Top
W
Hub
Opening
Meter
Socket
H
H
E,F,G
S
A,B,C,D C,D,E,F A,B,C,D
S A
A
2R
W
Hub
Opening
Meter
Socket
D
3R, 6R
Hub
Opening
W
D
W
Hub
Opening
Meter
Socket
Meter
Socket
Offset
H
C,D,E,F,G
S
S
C,D,E,F,G
F,G,H
1R
D
H
D,E,F,G
A
H
F,G,H
A,B
A
S
A,B
S
2
D,E,F,G
A
F,G,H
F,G,H
4R, 5R
8R
7R
D
W
METERING EQUIPMENT
Hub
Opening
Meter
Socket
D
W
D
Hub
Opening
H
F,G,H
F,G,H,I
A,B
A
S
A
Enclosure Dimensions
Hub
Opening
F,G,H,I
9R
10R
Box
Hub Opening
H
W
D
No.
(Max. Conduit Size) a
1R
10.88
8.00
3.50
Series A
2R
13.00
13.00
4.94
Solid Top
3R
14.00
8.00
4.38
Series A
4R
14.00
11.00
4.38
Series A
5R
15.00
11.00
4.38
Series A
6R
15.50
8.00
4.36
Series A
7R
17.13
13.00
4.94
(2) Series A
8R
19.00
10.50
4.94
Series A-L
9R
19.00
13.00
4.94
Series A-L
10R
34.50
15.00
5.68
Series A-L
11R
36.62
15.00
5.68
Series A-L
12R
43.00
20.25
6.00
Series A-L
13R
14.12
24.31
4.50
Series A
13R1
14.12
32.50
4.50
Series A
14R
14.12
40.62
4.50
Series A
15R
14.12
48.75
4.50
Series A
16R
14.12
57.00
4.50
Series A
17R
14.12
24.31
5.38
Series A
18R
14.12
40.62
5.38
Series A-L
19R
14.12
54.75
5.38
(2) Series A-L
20R
14.12
63.00
5.38
(2) Series A-L
aRefer to page 2-3 for closing plates and hubs.
Table 2.7:
A
Knockout Information
H
F,G,H,I
H
S
F,G,H
D
W
Meter
Socket
Offset
Meter
Socket
A,B
Table 2.6:
Dimensions (Inches)
Meter
Socket
Offset
H
A,B,C,D,E
D
Knockouts
Symbol
S
Conduit 5/16
Size (in.) b
S
A
B
C
1/2
3/4
1
D
E
1-1/4 1-1/2
Hub
Opening
G,H,I,J
H
Main
Lugs
S
C,D,E,F,G
(13R, 17R)
12R
Meter
Socket
H
S
A
C,D,E,F,G (13R)
F,G,H (17R)
C,D,E,F,G
(13R, 17R)
C,D,E,F,G
(14R, 18R)
D
Main
Lugs
C,D,E,F,G (14R)
F,G,H (18R)
Meter Socket
Left position omitted on
5-Gang unit (15R)
W
C,D,E,F,G
(14R, 18R)
Hub Opening
H
A
Main
Lugs
S
C,D,E,F,G
H
A
14R and 18R
W
S
4
Main
Lugs
13R and 17R
Meter
Socket
J
3-1/2
Hub Opening
Hub Opening
D
I
3
W
D
W
Meter
Socket
A,B
H
2-1/2
11R
D
Meter
Socket
G
2
bKnockout for ground conductor.
F,G,H,I
Hub Opening
W
F
C,D,E,F,G
H
A
C,D,E,F,G
13R1
C,D,E,F,G
7.50
191
22.44
570
Supplied with (2)
ACP Closing Plates.
Order A-Hubs
separately for
overhead service
feed.
C,D,E,F,G
15R and 16R
D
Meter Socket
Left position omitted on
5-Gang unit (19R)
W
Hub Opening (2 Locations)
Main
Lugs
30.00
762
C,D,E,F,G
S
C,D,E (3 Locations)
H
A
E,F,G,H (8 Locations)
C,D,E,F,G
(19R, 20R)
F,G,H
(19R, 20R)
C,D,E,F,G
(19R, 20R)
19R and 20R
A,B
EMT1225CB and EMT3225CB
2-4
© 2007 Schneider Electric
All Rights Reserved
Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com