Meter Sockets Horizontal Ganged, Test Block Bypass Sockets and Accessories www.us.schneider-electric.com Class 4131 FOR CURRENT INFORMATION Horizontal Ganged Meter Sockets • 1Ø, 600 Vac max., main lugs only, 2 through 6 meter positions, with and without horn or lever bypass, end or center feed, overhead and underground service feeds 10 kA short circuit current rating (or higher with utility approval) UL Listed, NEMA 3R enclosure Supplied with ground lugs Supplied with hub opening in top endwall, requires the use of a bolt-on hub, or closing plate • • • • This metering is generally utility specific. Always check with local utility company before installing. Contact your nearest Field Sales Office for additional catalog numbers, if required by utility. Ringless Type, 1Ø3W, 600 Vac Max., Without Bypass or Jaw Release Branch Ratings Socket Service No. of Amperesc Positions Jaw Type Qty.b 2 3 100 A 4 4 OH/UG 5 6 2 4 200 A 5 4 OH/UG 6 a b c Mains Rating (A) Cat. No. 200 205 205 250 300 205 360 UT2R1121B UT3R1121B UT4R1131B UT5R1131B UT6R1131B UT2R2122B UT4R2352T 302.00 373.00 440.00 605.00 771.00 431.00 737.00 500 UT5R2392TU 922.00 620 UT6R2392TU 1032.00 $ Price Top Endwalla Main Lugs Branch Lugs Phase & Neutral Phase Box No. & Neutral Hub Type Closing Plate See Al/Cu Page 2-4 (Order (Order Al/Cu (AWG) (AWG/kcmil) Separately) Separately) 6–250 13R 6–250 13R1 6–350 8–2/0 Series A ACP 14R 6–350 15R 6–350 16R 6–250 Series A ACP 17R 1/0–500 Series A-L ACPL 18R 1/0–500 or 8–250 Series A-L ACPL 19R (2)1/0–350 1/0–500 or Series A-L ACPL 20R (2)1/0–350 For Hubs and Closing Plates, see Accessories table below. Fifth Jaw Kit available to convert 4-Jaw Socket to a 5-Jaw Socket. See Accessories table below. Rating is continuous. Meter Mains with Test Block Bypass (Meets EUSERC Requirements) Table 2.3: Ring Type, 1Ø3W and 3Ø4W, Meter Main with Test Block Bypass (Meets EUSERC Requirements) Supplied with bondable neutral, suitable for use as service equipment. Suitable for overhead or underground service. UL Listed File E6294. EMT3225CB d e f g System (Incoming) Meter Ampere Short Circuit Main Circuit Breaker Type and Socket Rating Current Cat. No.f $ Price Rating (Order Separately)d Service (Outgoing) Type (Max.) 120/240 Vac 1Ø3W 5-Jaw 225 A 100 kA max. EMT1225CB 2730.00 2P Type QB, QD, QG, QJ, QOe, QO-VHe or QOHe 208Y/120 Vac 3Ø4Wg or 7-Jaw 225 A 65 kA max. EMT3225CB 3570.00 3P Type QB, QD, QG or QJ 240/120 Vac 3Ø4W Delta Refer to page 2-15 to select main circuit breaker. Requires use of EZM125QOA adapter (order separately), when using QO (40 A–125 A, 2-pole) 10kA max. SCCR, QO-VH (40 A–60 A, 2-pole) 22kA max. SCCR, or QOH (40 A–60 A, 2-pole) 42kA max. SCCR. Refer to page 2-15 for pricing. Refer to page 2-4 for box dimensions. 100 kA max. Table 2.4: METERING EQUIPMENT Table 2.2: 2 UT2R1121B EMT Terminal Wire Size h Line Phase Lug Line Neutral Lug Service Ground Lug 6 AWG–300 kcmil Al/Cu 6 AWG–350 kcmil Al/Cu 4 AWG–300 kcmil Al/Cu h Refer to circuit breaker listings for usable load lug wire sizes. Equipment Ground Lug 6 AWG–300 kcmil Al/Cu Load Neutral Lug 4 AWG–300 kcmil Al/Cu Meter Socket Accessories Table 2.5: Meter Socket Accessories Accessory EMT3225CB Without Covers Fifth Jaw Kit Closing Plates (to seal hub openings) Series A Hubs (listed by conduit size) Series A-L Series B Adapter Plate Lug Kits Sealing Ring i © 2007 Schneider Electric All Rights Reserved Description Cat. No. Converts a 4-jaw meter socket to a 5-jaw meter socket. A5J For use on meter sockets supplied without lever bypass or jaw release only. For Series A (steel) ACP For Series A (aluminum) ACPA For Series A-L (steel) ACPL For Series A-L (aluminum) ACPLA 1.00 inch A100 1.25 inch A125 1.50 inch A150 2.00 inch A200 2.50 inch A250 2.00 inch A200L 2.50 inch A250L 3.00 inch A300L 3.50 inch A350L 4.00 inch A400L 3.00 inch B300i To allow the use of a Series A Hub on a device that is setup for a series A-L Hub. AAP For use on meter sockets supplied with Line, Load, and Neutral Studs only. Be sure to order enough lugs for each device (a typical 1Ø device requires 6 lugs). Includes one, two-barrel lug (6-250 kcmil) ARP00118 Includes one, single barrel lug (4-600 kcmil) ARP00129 Includes three, two-barrel lugs (6-350 kcmil) ARP00427 Snap-on Aluminum (Standard) 2920910001 Snap-on Stainless Steel (Non-standard) ARP00026 Screw Type Aluminum (Non-standard) 29008W $ Price 9.90 8.90 7.90 12.20 11.00 22.60 22.60 22.60 31.90 40.40 55.00 58.00 74.00 76.00 79.00 124.00 22.50 25.40 36.80 90.00 5.30 11.10 13.40 DE1A Discount. DE4 DE1A Discount Schedule 2-3 Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com Meter Sockets Dimensions Class 4131 www.us.schneider-electric.com FOR CURRENT INFORMATION D W Hub Opening Meter Socket W D Solid Top W Hub Opening Meter Socket H H E,F,G S A,B,C,D C,D,E,F A,B,C,D S A A 2R W Hub Opening Meter Socket D 3R, 6R Hub Opening W D W Hub Opening Meter Socket Meter Socket Offset H C,D,E,F,G S S C,D,E,F,G F,G,H 1R D H D,E,F,G A H F,G,H A,B A S A,B S 2 D,E,F,G A F,G,H F,G,H 4R, 5R 8R 7R D W METERING EQUIPMENT Hub Opening Meter Socket D W D Hub Opening H F,G,H F,G,H,I A,B A S A Enclosure Dimensions Hub Opening F,G,H,I 9R 10R Box Hub Opening H W D No. (Max. Conduit Size) a 1R 10.88 8.00 3.50 Series A 2R 13.00 13.00 4.94 Solid Top 3R 14.00 8.00 4.38 Series A 4R 14.00 11.00 4.38 Series A 5R 15.00 11.00 4.38 Series A 6R 15.50 8.00 4.36 Series A 7R 17.13 13.00 4.94 (2) Series A 8R 19.00 10.50 4.94 Series A-L 9R 19.00 13.00 4.94 Series A-L 10R 34.50 15.00 5.68 Series A-L 11R 36.62 15.00 5.68 Series A-L 12R 43.00 20.25 6.00 Series A-L 13R 14.12 24.31 4.50 Series A 13R1 14.12 32.50 4.50 Series A 14R 14.12 40.62 4.50 Series A 15R 14.12 48.75 4.50 Series A 16R 14.12 57.00 4.50 Series A 17R 14.12 24.31 5.38 Series A 18R 14.12 40.62 5.38 Series A-L 19R 14.12 54.75 5.38 (2) Series A-L 20R 14.12 63.00 5.38 (2) Series A-L aRefer to page 2-3 for closing plates and hubs. Table 2.7: A Knockout Information H F,G,H,I H S F,G,H D W Meter Socket Offset Meter Socket A,B Table 2.6: Dimensions (Inches) Meter Socket Offset H A,B,C,D,E D Knockouts Symbol S Conduit 5/16 Size (in.) b S A B C 1/2 3/4 1 D E 1-1/4 1-1/2 Hub Opening G,H,I,J H Main Lugs S C,D,E,F,G (13R, 17R) 12R Meter Socket H S A C,D,E,F,G (13R) F,G,H (17R) C,D,E,F,G (13R, 17R) C,D,E,F,G (14R, 18R) D Main Lugs C,D,E,F,G (14R) F,G,H (18R) Meter Socket Left position omitted on 5-Gang unit (15R) W C,D,E,F,G (14R, 18R) Hub Opening H A Main Lugs S C,D,E,F,G H A 14R and 18R W S 4 Main Lugs 13R and 17R Meter Socket J 3-1/2 Hub Opening Hub Opening D I 3 W D W Meter Socket A,B H 2-1/2 11R D Meter Socket G 2 bKnockout for ground conductor. F,G,H,I Hub Opening W F C,D,E,F,G H A C,D,E,F,G 13R1 C,D,E,F,G 7.50 191 22.44 570 Supplied with (2) ACP Closing Plates. Order A-Hubs separately for overhead service feed. C,D,E,F,G 15R and 16R D Meter Socket Left position omitted on 5-Gang unit (19R) W Hub Opening (2 Locations) Main Lugs 30.00 762 C,D,E,F,G S C,D,E (3 Locations) H A E,F,G,H (8 Locations) C,D,E,F,G (19R, 20R) F,G,H (19R, 20R) C,D,E,F,G (19R, 20R) 19R and 20R A,B EMT1225CB and EMT3225CB 2-4 © 2007 Schneider Electric All Rights Reserved Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com