Railway-EMC-Standards prEN 50121-X EMC TEST NRW www.emc-test.de Welcome at the independent service provider for EMC EMC Solutions - the first choice 1 15.09.2006 Uwe Rörden Revision prEN 50121-X : 2006 www.emc-test.de Overview EMC standards EMC TEST NRW Current standard Title EN 50121-1 : 09.2000 Railway application – Electromagnetic compatibility; Part 1: Generell EN 50121-2 : 09.2000 Railway application – Electromagnetic compatibility; Part 2: Emission of the whole railway system to the outside world EN 50121-3-1 : 09.2000 Railway application – Electromagnetic compatibility; Part 3-1: Rolling stock – Train and complete vehicle EN 50121-3-2 : 09.2000 Railway application – Electromagnetic compatibility; Part Teil 3-2: Rolling stock – Apparatus EN 50121-4 : 09.2000 Railway application – Electromagnetic compatibility; Part 4: Emission and immunity of the singalling and telecommunications apparatus EN 50121-5 : 09.2000 Railway application – Electromagnetic compatibility; Part 5: Emission and immunity of fixed power supply installations and apparatus 2 15.09.2006 Uwe Rörden Revision prEN 50121-X : 2006 EMC TEST NRW prEN 50121-x : 02.2006 Reasons for revision ... www.emc-test.de ¾ adaptation to technical progress ¾ e.g. expansion of frequency range (WLAN, Bluetooth, ...) ¾ unification of measurement procedures ¾ e.g. reference to standards EN 61000-4-x ¾ elimination of mistakes / better understanding 3 15.09.2006 Uwe Rörden Revision prEN 50121-X : 2006 www.emc-test.de Changes in prEN 50121-3-1 EMC TEST NRW EN 50121-3-1 : 2000 prEN 50121-3-1 : 2006 Radiated emission with special measurement procedure in standstill and slow moving with PEAK-detector (MAXHold) / 1 antenna polarisation Radiated emission with special measurement procedure in standstill with QP-detector / MAX-Hold) and slow moving with PEAK-detector / MAXHold / 2 antenna polarisations Change of limit lines and measurement procedure in standstill operation ! Conducted and radiated immunity not tested. EMC plan for vehicle must be set up and implemented. No change in requirements ! Conducted and radiated immunity not tested. EMC plan for vehicle must be set up and implemented. Comment 2 antenna polarisations ! Higher expenditure of time ! 4 15.09.2006 Uwe Rörden Revision prEN 50121-X : 2006 Changes in prEN 50121-3-2 www.emc-test.de EN 50121-3-2 : 2000 prEN 50121-3-2 : 2006 EMC TEST NRW Comment Radiated emission according to EN 55011 Radiated emission according to EN 55011 No change in requirements ! Conducted emission according to EN 55011 Conducted emission according to EN 55011 No change in requirements ! Radiated immunity according to EN 61000-4-3 80-1000 MHz with 10/20 V/m Radiated immunity according to EN 61000-4-3 80-1000 MHz with 20/10 V/m 800-1000 MHz with 20 V/m 1400-2100 MHz with 10 V/m 2100-2500 MHz with 5 V/m Change of test procedure for 900 MHz and expansion of frequency range up to 2,5 GHz ! Additional test with higher expenditure of time ! Conducted immunity according to EN 61000-4-2/4/-6 and EN 50155 (SURGE / voltage variations and dips) Conducted immunity according to EN 61000-4-2/-4/-5/-6 No test of voltage variations and dips ! EN 61000-4-6 now with 10V ! Higher SURGE-test => damage of apparatus ? 5 15.09.2006 Uwe Rörden Revision prEN 50121-X : 2006 Changes in prEN 50121-4 www.emc-test.de EN 50121-4 : 2000 Comment Radiated emission according to EN 50081-2 Radiated emission according to EN 61000-6-4 No change in requirements ! Conducted emission according to EN 50081-2 and EN 61000-3-x Conducted emission according to EN 61000-6-4 and EN 61000-3-x No change in requirements ! Radiated immunity according to EN 61000-4-3 80-1000 MHz with 10V/m ; and ENV 50204 900±5 MHz with 10 V/m Radiated immunity according to EN 61000-4-3 80-1000 MHz with 10V/m 800-1000 MHz with 20 V/m 1400-2100 MHz with 10 V/m 2100-2500 MHz with 5 V/m Change of test procedure for 900 MHz and expansion of frequency range up to 2,5 GHz ! Magnetic fields test according to EN 61000-4-8 with 50Hz, 100 A/m EN 61000-4-9 with 300 A/m 6 prEN 50121-4 : 2006 EMC TEST NRW Conducted immunity according to EN 61000-4-2/-4/5/-6 15.09.2006 Uwe Rörden Magnetic fields test according to EN 61000-4-8 with 0/16,7/50Hz, 100 A/m AC-system and 300 A/m DC-system EN 61000-4-9 with 300 A/m Conducted immunity according to EN 61000-4-2/-4/-5/-6/-12 Additional test with higher expenditure of time ! No change in requirements ! Revision prEN 50121-X : 2006 Changes in prEN 50121-5 www.emc-test.de EN 50121-5 : 2000 prEN 50121-5 : 2006 EMC TEST NRW Comment Radiated emission according to EN 50081-2 Radiated emission according to EN 61000-6-4 No change in requirements ! Conducted emission according to EN 50081-2 and EN 61000-3-x Conducted emission according to EN 61000-6-4 and EN 61000-3-x No change in requirements ! Radiated immunity according to EN 61000-4-3 80-1000 MHz with 10V/m ; and ENV 50204 900±5 MHz with 10 V/m Radiated immunity according to EN 61000-4-3 80-1000 MHz with 10V/m 800-1000 MHz with 20 V/m 1400-2100 MHz with 10 V/m 2100-2500 MHz with 5 V/m Change of test procedure for 900 MHz and expansion of frequency range up to 2,5 GHz ! Magnetic fields test according to EN 61000-4-8 with 50Hz, 100 A/m Magnetic fields test according to EN 61000-4-8 with 0/16,7/50Hz, 100 A/m Conducted immunity according to EN 61000-4-2/-4/5/-6/-12 Conducted immunity according to EN 61000-4-2/-4/-5/-6/-12 + EN 61000-6-4 on earth connection Additional test with higher expenditure of time ! One additional test. 7 15.09.2006 Uwe Rörden Revision prEN 50121-X : 2006