Toshiba’s Petrochem SD+ Medium Voltage Motor – Rugged Construction for Ultimate Durability. This totally enclosed fan cooled motor package offers severe duty IP55 protection for the toughest material processing applications such as compressors, pumps, fans, and conveyors. Its low temperature and low vibration design provides additional durability to withstand these harsh environments, decreasing maintenance requirements and chances of failures while ultimately increasing the motor’s lifespan. Built with certain IEEE Std. 841™ -2009 specifications, Toshiba’s Petrochem SD+ motor is the ideal solution for the oil and gas, mining and mineral, and pulp and paper industries. Better Protection Against the Toughest Applications • IP55 Degree of Protection for Motor & T-Boxes • Gasketed Main T-Box & Auxiliary T-Box • Non-Contacting Labyrinth Seals on Both Bearings • Lead Separator Gaskets • Insulation System Capable of Withstanding an Immersion Test in Accordance with NEMA MG 1 • Corrosion-Resistant Drain & Breather at Lowest Part of Motor Frame & Inside Main T-Box • Tropicalization Treatment on Windings • Precision Unfiltered Vibration Velocity • Cast Iron Frame & Brackets with Cast Iron or Fabricated Steel Terminal Box(es) & Fan Cover • 2-Pole: 0.10 Inches/Second • 4- & 6-Pole: 0.08 Inches/Second • Grounding Lugs on Motor Frame & Inside Main T-Box • 8-Pole: 0.06 Inches/Second • 0.005-Inch Precision Foot Flatness • Severe Duty, Corrosion-Resistant, Rust-Inhibitive Paint System on Motor & Shaft/Rotor Assembly • Non-Sparking, Epoxy-Coated Aluminum Internal Fan • Direction of Rotation Arrow for Motors with Uni-Directional Rotation • Corrosion-Resistant Hardware • Standard Non-Witnessed Routine Testing per IEEE 112 *Motors are not fully IEEE Std. 841™ -2009 compliant and will not include an IEEE Std. 841™ marking. See back for comments and exceptions. PETROCHEM SD+ MEDIUM VOLTAGE MOTOR PETROCHEM SD+ GENERAL SCOPE Frame Size Pole Speed Target Output Voltage Frequency Insulation Service Factor Time Rating Efficiency Applicable Standards 449/5011/5811 Series, Multi-Mount; Direct-Coupled & Belt-Drive (4-Pole & Greater) 2-, 4-, 6-, or 8-Pole 100 to 500 HP 2300, 3300, or 4000 V (Dual-Voltage 2300/4000 V Option Available) 50 or 60 Hz Class F 1.15 Continuous Standard Toshiba High Efficiency Design NEMA MG 1, IEEE 112, IEEE Std. 841 (ToshibaSelected Features), CSA Construction (Upon Request) OPERATING CONDITIONS Environment Ambient Temperature Humidity Altitude Enclosure Starting Method Starting Duty Area Classification Indoor or Outdoor –25° to 40°C <100% <3300 Feet (1000 Meters) TEFC, Cast Iron Fin-Type Direct On-Line, per NEMA MG 1 (1) Hot or (2) Cold Class I, Division 2, Groups B/C/D, T3 Temperature Code BEARING DETAILS Type Lubrication Type Insulation Provisions Shaft Material Core Plate Frame/Brackets Rotor Cage Space Heater Winding • Fans • Conveyors 4.2: Frame size may deviate from the frame size assignments specified in NEMA MG 1 Part 13. 4.5: IP55 ingress test will not be performed, but the motors are designed to meet the intent of IP55. 5.2: Some motors may have NEMA Design A torque/current characteristics. 5.4.1.c: IEEE Std 275-1992 is a withdrawn standard which shall no longer apply. 5.4.1.d: Surge withstand capability may only meet that as defined for standard machines in section 20.35.5 of NEMA MG 1-2011. 5.4.1.h: The use of synthetic oil-based lubricants is not recommended. 6.1.f: Bearing temperature rise may exceed the respective specified value. 6.4: Nonsparking epoxy coated Aluminum fan will be provided in lieu of the required bronze alloy. All 2 pole motors will be uni-directional. 6.5.3.d: 6 or more leads may be used when special requirements dictate the necessity. 6.8.b: Sound test will not be performed unless specifically requested by the customer and quoted by Toshiba. 6.9: Vibration limits may exceed the specified design values. See Page 1 of this document or contact Toshiba for our target unfiltered vibration velocity design values. Horizontal Foot Mounting 4-, 6-, & 8-Pole Bi-Directional; 2-Pole Uni-Directional Main T-Box F1 Assembly Three or Six 1045 Hot Rolled Steel Shaft on 4-Pole & Slower; 4142 Material on 2-Pole & Belted Applications C5 Cast Iron Die Cast Aluminum as Standard; Copper Bar Option Available Single-Phase, 120 V, Low-Temperature Form-Wound Stator Coils with Embedded 100 Ω Platinum Winding RTDs (Two per Phase) APPLICABLE APPLICATIONS: • Compressors • Pumps 1.[1-2]: Premium efficiency design will not be met in most cases. Standard Toshiba high efficiency design will be provided. 6.8.a: 90 dBA sound power level will be exceeded in most cases. Standard Toshiba sound level by design will be provided. Anti-Friction Polyurea-Based Grease NDE Bearing Only for 100 Ω Platinum Bearing RTDs (One per Bearing) CONSTRUCTION DETAILS Mounting Direction of Rotation T-Box Location Number of Leads COMMENTS & EXCEPTIONS TO IEEE STD. 841™-2009: 8: Full load efficiency may exceed the values listed in Table 2. Standard Toshiba high efficiency design will be provided. 9.4: Standard Toshiba test submittals will be provided. 10: Standard Toshiba nameplate(s) will be provided. Nameplate will not be marked/labeled with the IEEE Std 841 logo. Motors will not be fully compliant with IEEE Std 841. Guaranteed minimum efficiency will not be stated on the nameplate unless specifically requested by the customer and quoted by Toshiba. Annex A: Only Standard Toshiba non-witness routine testing per IEEE 112 will be performed. Additional testing is available for extra costs. **The comments above shall be used for reference only and may not address all the deviations from IEEE Std 841-2009 our motors exhibit. APPLICABLE INDUSTRIES: • Oil & Gas • Mining & Minerals • Pulp & Paper www.toshiba.com/tic © 2015 Toshiba International Corporation • Motors & Drives Division • 13131 West Little York Road • Houston, Texas 77041 USA • Tel +713-466-0277 US 1-800-231-1412 • Rev. 151215