NOARK Electric (Shanghai) Co., Ltd, as a subsidiary of CHINT Group (located in Shanghai with an area of approximately 391 acres), is committed to bring a high-end brand to low voltage electrical market. With over 45 million US dollar investment, NOARK Electric is equipped with the most up-to-date technologies and production facilities. A professional R&D team, comprised of more than 100 professors and doctors possessing some exclusive technologies patents such as modern simulation, has been working hard to achieve the intelligent low voltage distribution and control products line with high quality, performance and stability. The first generation Ex9 series of intelligent low voltage electrical products, incorporating the latest design, electronic and simulation technologies, reach the top industry expectations. This product series not only set multiple functions into ever smaller size, but also includes data acquisition, communications, and intelligent remote control modules, which reward Noark with up to 54 exclusive patents including invention, practical application and design. We firmly adhere to the concept of "best products derive from best raw materials ", which is also the principle of production. It is realized by cooperating with qualified suppliers with a very high selection standard. NOARK Electric is the first Chinese company in low voltage electrical industry implementing ISO/TS 16949 quality system. Besides complying with all compulsory domestic standards, full range of products is accredited by CB organization based on up-to-date IEC standards. Through a global marketing network, Noark has successfully contributed its efforts to provide complete solution and highlyefficient, highly-reliable,highly-intelligent and energy-saving low voltage products to some sophisticated industry areas, such as power, smart grid, renewable energy,petrochemical, machinery manufacturing, real estate and construction. We Believe, Remarkable technical innovations bring reliable products! Advanced technical ideas create intelligent electrical apparatus for the future! Contents Features 01 Product Overview Product Advantages Standards and Certifications Operating Conditions 01 02 06 06 Functions 07 Parameters 08 Ex9M Series Circuit Breaker for Power Distribution Protection Ex9M Series Circuit Breaker for Motor Protection Ex9M Switch Disconnector EX9MD Series DC Circuit Breaker 08 10 12 16 Accessories 16 Ex9ML Residual Current Protection Module Internal Accessories External Accessories 16 17 18 Selection 20 Ex9M Moulded Case Circuit Breaker Ex9M Moulded Case Circuit Breaker(Electronic type) Ex9MSD Switch Disconnector Ex9ML Residual Current Protection Module Accessories 20 21 22 23 24 Features Product Overview Thermal-magnetic type . Electronic type AC distribution protection AC distribution protection DC distribution protection Motor protection Motor protection Switch disconnector Residual current protection AC Residual current protection DC switch disconnector AC switch disconnector Several breaking capacities exist for each model of circuit breaker, meeting the demands for varying types of protection: Standard type - S and N Used in residential building, public buildings and industrial plants 150kA 120kA High-breaking capacity type - Q, R and H Used in industrial production line and key electric power equipment 100kA 85kA Current limiting type - V and P Used in heavy industry and special industry 70kA 50kA 36kA Ex9M5 Ex9M4 Ex9M3 Ex9M2 Ex9M1 S N Q R H V P For each Ex9M circuit breaker, several rated current levels are available. Model Rated current (A) 16 20 25 32 40 50 63 80 100 125 160 180 200 225 250 315 350 400 500 630 700 800 Ex9M1 Ex9M2 Ex9M3 Ex9M4 Ex9M5 Ex9M1 is adjustable for thermal protection, range: IR=(0.8~1.0)In Ex9M2 is adjustable for thermal and magnetic protection, range: IR=(0.8~1.0)In,Ii=(5~10)In Ex9M3 Ex9M4 and Ex9M5 is the same as Ex9M2 01 Features Switch Disconnector [Primary distribution panel] A product equal to the size of the circuit breaker, commonly used in the connection and isolation between the power loads consumers and different busbars. ≤1000A Cannot cut off the short-circuit current, has no protective functions, and may be used in conjunction with the fuse. ≤1600A 15-40kA [Secondary distribution panel] ≤400A ≤63A ≤63A ≤10kA ≤40A ≤25kA M M Patented [Control cabinet] ≤630A ≤10kA M Building utilities ≤160A:15-25kA ≤400A:20-80kA [Terminal [Control distribution panel] cabinet] [Control cabinet] Product Advantages [Secondary distribution panel] 15-25kA ≤160A Bearing type axis 20-80kA ≤6kA M M Terminal power Continuous Production facilities distribution for process control and individual equipment buildings technology The innovative rotating shaft with bearing allows the circuit breaker to: * Smaller main tension spring force and mechanism friction force * Lower mechanism abrasion * A more quick and flexible mechanism action The innovative rotating shaft with bearing brings the user: * A type of high-performance circuit breaker with the smallest operational force Model Operational force Ex9M1 Ex9M2 3P 3P 4P 4P Ex9M3 3P 4P Ex9M4 3P 4P Ex9M5 3P 4P Closing force 44N 46N 55N 82N 80N 98N 110N 121N 110N 121N Opening force 24N 24N 39N 55N 77N 89N Re-tripping force 36N 38N 36N 54N 102N 115N 133N 148N 133N 148N 98N 115N 98N 115N A kind of durable, high-performance circuit breaker: * The user will be able to reduce the frequency and cost of changing the circuit breaker due to its longer endurance. Mechanical life (cycles) Electrical life (cycles) 5000 15000 5000 15000 1000 7000 10000 7000 10000 4000 4000 2000 Ex9M1 standard* 1000 2000 Ex9M2 standard* 1000 Ex9M3 1000 standard* Ex9M4 500 standard* Ex9M5 standard* 5000 Ex9M1 4000 standard* Ex9M2 standard* 2500 Ex9M3 standard* Ex9M4 standard* Ex9M5 standard* 02 Features Snap action Patented technology The breaking speed of the circuit breaker is accelerated (breaking time within 2ms), and its breaking capacity and current capacity are improved by utilizing gas-flushing principle. There are several different breaking capacities for each model of the Ex9M circuit breaker. Therefore, users may choose the most optimal breaker as per their actual demands. The maximum breaking capacity of each model of Ex9M circuit breaker is up to 150 kA. I 【Gas-Flushing Principle】 When the circuit breaker breaks the short circuit current, large quantities of high-temperature and high-pressure gas will be generated. A special gas flow path is designed for the Ex9M breaker, which will lead gas being generated to the fast-actuating mechanism. The auxiliary mechanism is activated by the gas pressure, and the entire breaking time may be controlled within 2 ms. Consequently, the damages caused by the short circuit current to the electric components and the busbar are greatly decreased. Prospective peak value Prospective short circuit current Current limiting means the limiting increase of the short circuit current in a circuit. In a circuit protected by the Ex9M product series, both the peak value and energy I2t of the short circuit current generated are far less than expected. Actual peak value Limited let-through current Energy after current-limiting U-Type repulsive electrical circuit, intensifies the repulsion forces and creates a fast-contact opening. I Current-limiting capacity T Upper fixed contact Force F1 Force F2 ILower fixed contact U-Type fixed contact design The pre-breaking technique may be realised by means of a unique U-Type fixed contact. The pre-breaking technique refers to that of the electrodynamic force generated through the U-Type fixed contact and that which occurs on moving contact are mutually repulsed when the short circuit current flows through acontact system. The higher the short circuit current, the bigger the repulsive electrodynamic forces they generate simultaneously. Prior to releasing, the electrodynamic repulsive forces may separate the moving contact from the fixed contact, and the equivalent resistance between these two contacts is increased by stretching the electrical arc. Double break design The current-limiting function of the pre-breaking technique is enhanced because of an increase in instantaneous arc resistance and arc voltage and a fast drop in the current increase rate. Reduces the damage and loss of equipment and the power lines caused by a short circuit current, improves the safety, and cuts down on the cost of a secondary protection device. AX AL AX Modularized design Circuit breakers: For circuit breakers within the same frame, without reference to the size of the breaking capacity and rated current, the dimension is the same. Accessories: Users may select accessories as per their demands and expand the functions of the circuit breakers. 03 Features NO Designation 1 2 3 4 Auxiliary alarm contact Under-voltage release Shunt release Interface barrier Residual current protection 5 module 6 Electronic release 7 Thermo-(magnetic) release 8 Terminal shield Manual operating 9 mechanism 10 Motor mechanism 11 Plug-in base 12 Drawout base AX(AL) UVT SHT PHS Ex9ML SU20 TM(M) TCV ERH/RHD MOD PIA DOB Advanced magnetic field analysisz For a circuit breaker, the distribution of the magnetic field in its contact system has a direct impact on its performance, but the magnetic field is not visible. Distribution of magnetic field between contacts e L N i e e e i Arc is pushed into the arc-quenching chamber due to the magnet effect. Moving contact Fixed contact Magnetic-blow quenching principle 04 The Ex9M is designed by combining the overall simulation technique with several tests which enables a rational distribution of the magnetic field and endows a circuit breaker with excellent performance capabilities: Ensuring that a strong electrodynamic repulsion force will be generated as soon as a short-circuit occurs. Ensuring that the electrical arc can be blown into the arcing chamber instantly. Ensuring that there will be sufficient pressure between the moving contact and the fixed one when the circuit breaker functions normally and the contact resistance between the two contacts is sufficiently low. Features Optimized dimensions For easier installation and more space-saving capabilities, the volume of the Ex9M circuit breaker is designed and manufactured in a compact size and light weight, while its excellent performance is maintained. A kind of delicate & compact moulded case circuit breaker - Ex9M1 (125 A) Size: 140 mm × 90 mm × 79 mm (L × W × H) Even for higher current levels, Ex9M maintains its advantage of small size. Additionally, the required mounting space is further reduced effectively due to its innovative zero flashover design. Several ways for mounting and the introduction of incoming lines allow for better mounting by adapting to different installation practices. LINE ON OFF LOAD LINE LINE ON ON ON OFF OFF ON Zero flashover Zero flashover OFF ON Zero flashover OFF Zero flashover Mounting direction LOAD LOAD OFF LOAD LINE Power supply from the top or bottom Environmentally-friendly Design/Manufacturing The Ex9M does not contain any noxious or hazardous substances, and its manufacturing and processing processes are performed in accordance with the requirements of the ISO 14001. Operation Low temperature rise, low power consumption, and minor influences to the surrounding environment during operation. Distribution Environmentally-protective materials are used in the course of distribution. Recycling Over 80% of its component materials can be recycled and reused at the end of its service life. 05 Features Standards and Certifications s International standards Product standards IEC 60947-1 (General provisions) IEC 60947-2 (Circuit breakers) IEC 60947-3 (Switches, isolation) IEC 60947-4-1 (Motor starters) Extreme environmental test standards IEC 60068-2-1 (Low temperature) IEC 60068-2-2 (Dry heat) IEC 60068-2-11 (Salty mist test) IEC 60068-2-30 (Moist heat) Operating Conditions Temperature May be used in temperatures from -25oc ~ +70oc. If the necessary working temperature is below -5oc or above+40oc, use it according to those specified in the table of temperature compensation coefficient or please contact us for additional information Altitude Normally, the altitude above sea level at its installation site should not exceed 2,000 m. If having to install at an altitude above 2,000 m, use it according to those specified in the table of altitude-derating factors or please contact us if you have any questions and / or concerns. Humidity The following conditions must be met during normal operation: If the ambient air temperature is +40oc, the atmospheric relative humiditycan not exceed 50%. If the temperature is lower, use it under the conditions for a higher degree of humidity. The monthly mean relative humidity needs to be below 90% in the dampest month. The effects of condensation on the product surface impacts its performance and needs to be taken into consideration. Every product has been tested by strictly following the requirements given by IEC60068-2-30 Pollution Level Level 3 06 thermal-magnetic IR Ii 1.0 10 5 9 6 0.9 0.8 xIn 8 TM 250 250A/40℃ 7 xIn Overload protection Set current value IR=(0.8-0.9-1.0)×In±15% Short-circuit protection (Ex9M1 not adjustable) Set current value Ii=(5-6-7-8-9-10)×In±15% Instantaneous ti≤50ms N-pole protection Ex9M1 M2 ■ ■ No protection IR/2protection — — ■ ■ IRprotection Protective operating characteristics No. Test current I/In Conventional 1.05 1 non-releasing current Conventional 1.3 2 releasing current IR Ii Main Functions Code Electronic For protection of general power distribution Functions Models M4 M5 ■ ■ ■ — — — ■ ■ ■ Release time Initial state >1h(In≤63A) Cold state >2h(In>63A) ≤1h(In≤63A) ≤2h(In>63A) After test 1 Main Functions SU20S Basic electronic distribution protection SU20SM Basic electronic motor protection SU20C Advanced electronic distribution protection long-time overload protection, short time short circuit protection, instantaneous short time protection, neutrol pole protection for 4P MCCBs only, failure recording, self-monitoring, current measurement, bilingual display protection, short time thort circuit protection, instantaneous short time protection, neutrol pole protection for 4P MCCBs only, failure recording, selfmonitoring, current measurement,bilingual bilingual display zone interlocking,thermal memory,frequency measurement, harmonic measurement Advanced electronic motor protection SU20CM M3 The LED indicator instructions “Ready”, Its stable blink indicates normal working status.It turns off in case of failure “Alarm”, It turns on when the actual current >= 90% IR It turns off when the actual current <105% IR “Overload” It turns on when the actual current >=105% IR It turns off when the actual current <105% IR navigation key Communication port For motor protection Noark LCD Motor protection Magnetic Ii 14 9 13 12 10 11 xIn Thermal relay + contactor overload protection + switching Circuit breaker short circuit protection M 250 250A Set current value Instantaneous For short-circuit protection of the motor, the set value should be higher than the starting current to avoid false releasing at the start of the motor. L T(s) Ta Class Ii M Short-circuit protection Ii=(9-10-11-12-13-14) ×In±15% ti≤50ms R (9-14)In TP Circuit breaker with magnetic protection Isolation Short-circuit protection Ie I 1 Ia Ip Contactor Power on/power off Overload protection executed Selective protection Cascade protection I1 Ia Ta M Tp M Relay releasing current, function L Motor return current curve Short-time starting peak current Motor starting duration Typical motor starting curve Typical motor starting curve Selective protection refers to the circuit breaker (D2) closest to the fault breaks off and the circuit breaker (D1) upstream doesn’t actuate, ensuring that the circuit breaker (D3) on a normal branch of the circuit makes and supplies power. D1 D2 I(A) Ie Motor rated working current Ip Stand-alone thermal relay Overload protection For protection of general power distribution Protection LED Indicator D3 Selective protection enables the effective limit on the influence range of a fault. A cascade connection is the direction application of the current-limiting capacity of a circuit breaker. D1 D2 The downstream circuit breaker, under protection by the upstream circuit breaker,may break off the shortcircuit current which is out of its breaking capacity. Users can select low-cost downstream circuit breakers. 07 Parameter Ex9M Series Circuit Breaker for Power Distribution Protection Ex9M1 Ex9M2 2P/3P/4P 125 2P/3P/4P 250 50/60 380/400/415/660/690 16-20-25-32-40-50-63-80-100-125 800 8 S N Q R H V P 36 50 70 85 100 120 150 5 5 5 5 6 6 8 100% 100% ■ A 15000 7000 5000 1000 50/60 380/400/415/660/690 125-160①-180-200-225-250① 800 8 N Q R H V 50 70 85 100 120 6 6 6 8 8 100% 100% ■ A 15000 7000 5000 1000 For protection of general power distribution Number of poles Rated frame current (A) Electric performance Working frequency(Hz) Rated operational voltage(V) Rated current (A) Rated insulation voltage (V) Rated impulse withstand voltage (kV) Type of breaking Ultimate breaking capacity (kA) Icu Service breaking capacity (% Icu) Ics Ue In +40oc Ui Uimp 380/400/415V 660/690/720V 415V 690V Isolation function Utilization category Service life (C-O cycle) Actual mean value Test value Actual mean value Test value Mechanical Electrical 415V S 36 6 Protection Magnetic Thermomagnetic Electronic SU20S Basic type SU20C Advanced type Long-time delay Short-time delay Instantaneous Long-time delay Instantaneous Long-time delay Short-time delay Instantaneous Residual current protection Control and indication — — — — 12×In (9-10-11-12-13-14)×In (0.8-0.9-1.0)×In (0.8-0.9-1.0)×In 10×In (5-6-7-8-9-10)×In — (0.4~1.0)×In — (1.5~10)×Ir — (1.5~12)×In RCD1(0.03A-0.1A-0.3A-1A Adjustable;RCD2(0.05A-0.2A-0.5A-2A Adjustable) Direct (RHD) Extended(ERH) Motor mechanism(MOD) Shunt release (SHT) □ □ □ □ □ □ □ □ Under-voltage release □ □ □ □ □ □ IP40 IP20 Front/Rear □ — □ — ON/OFF position ■ □ 62/90/120 140 81.6 0.9 1.2 1.7 IP40 IP20 Front/Rear □ — □ — ON/OFF position ■ □ 70/105/140 157 91.5 1.2 1.7 2.2 Control mode Manual (UVT) Auxiliary contact (AX) Alarm contact (AL) Connection and installation All sides Wiring terminal Degree of protection Wiring Terminal shield (TCV) Wiring assembly Plug-in base(PIA) Draw-out base(DOB) Front Rear Key lock (KLK) Phase board (PHS) Mechanical interlock(MIT) a(2*/3/4) b c External dimensions (mm) W×H×D 2P 3P 4P Weight (kg) Standard Optional — No *only Ex9M1,Ex9M2 have 2P. Note①:Rated current of electronic MCCB, rated current of electronic Ex9M2 is 250A, 160A, 100A, 63A and 32A. 08 P 150 10 S 36 10 N 50 10 Ex9M3 Ex9M4 Ex9M5 3P/4P 400 3P/4P 630 3P/4P 800 50/60 380/400/415/660/690 250-315-350-400① 800 8 Q R H 70 85 100 10 10 12 100% 100% ■ A 10000 4000 2000 1000 50/60 380/400/415/660/690 400-500-630① 800 8 N Q R H V 50 70 85 100 120 10 10 10 12 12 100% 100% ■ A 10000 4000 2000 1000 50/60 380/400/415/660/690 630-700-800① 800 8 N Q R H V 50 70 85 100 120 10 10 10 12 12 100% 100% ■ A 5000 2500 1000 500 V 120 12 P 150 15 — — (9-10-11-12-13-14)×In (0.8-0.9-1.0)×In (5-6-7-8-9-10)×In (0.4~1.0)×In (1.5~10)×Ir (1.5~12)×In S 36 10 P 150 15 S 36 10 RCD3(0.05A-0.2A-0.5A-1A Adjustable;RCD4(0.1A-0.3A-1A-2A Adjustable) — — (9-10-11-12-13-14)×In (0.8-0.9-1.0)×In (5-6-7-8-9-10)×In (0.4~1.0)×In (1.5~10)×Ir (1.5~12)×In — — — (9-10-11-12-13-14)×In (0.8-0.9-1.0)×In (5-6-7-8-9-10)×In (0.4~1.0)×In (1.5~10)×Ir (1.5~12)×In — □ □ □ □ □ □ □ □ □ □ □ □ □ □ □ □ □ □ □ □ □ IP40 IP20 Front/Rear □ □ □ — ON/OFF position ■ □ 140/185 255 118.5 — 5.0 6.6 IP40 IP20 Front/Rear — □ □ — ON/OFF position ■ □ 195/260 300 142 — 10.2 13.5 IP40 IP20 Front/Rear — □ □ — ON/OFF position ■ □ 195/260 300 142 — 10.2 13.5 P 150 15 09 Parameter Ex9M1M Ex9M2M 2P/3P/4P 125 2P/3P/4P 250 50/60 380/400/415/660/690 16-20-25-32-40-50-63-80-100-125 800 8 N Q R H V Ex9M Series Circuit Breaker for motor protection For motor protection Number of poles Rated frame current (A) Electric performance Working frequency(Hz) Rated operational voltage (V) Ue Rated current (A) In Rated insulation voltage (V) Ui Rated impulse withstand voltage (kV) Uimp Type of breaking Ultimate breaking capacity (kA) Icu Service breaking capacity (% Icu) Ics P S 50/60 380/400/415/660/690 125-160①-180-200-225-250① 800 8 N Q R H V 380/400/415V 36 50 70 85 100 120 150 36 50 70 85 100 120 150 660/690/720V 415V 690V 5 5 5 5 100% 100% ■ A 15000 7000 5000 1000 6 6 8 6 6 6 6 100% 100% ■ A 15000 7000 5000 1000 8 8 10 S Isolation function Utilization category Service life (C-O cycle) Actual mean value Test value Actual mean value Test value Mechanical Electrical Protection Long-time delay Short-time delay Instantaneous Long-time delay Instantaneous Magnetic Electronic SU20S Basic type SU20C advanced type Residual current protection Control and indication Control mode Direct(RHD) Extended(ERH) Manual Motor mechanism(MOD) Shunt release(SHT) Under-voltage release(UVT) Auxiliary contact(AX) Alarm contact(AL) Connection and installation All sides Degree of protection Wiring terminal Wiring assembly Wiring Plug-in base(PIA) Draw-out base(DOB) Front Terminal shield(TCV) Rear Handle lock(KLK) Phase board(PHS) Mechanical interlock(MIT) a(2*/3/4) b c External dimensions (mm) W×H×D Weight (kg) Fixed before connection ■ Yes 10 □ Optional 2P 3P 4P — NO * — — — — 12×In (9-10-11-12-13-14)×In — — — (1.5~14)×In RCD1(0.03A-0.1A-0.3A-1A Adjustable;RCD2(0.05A-0.2A-0.5A-2A Adjustable) □ □ □ □ □ □ □ □ □ □ □ □ □ □ IP40 IP20 Front/Rear □ — □ — ON/OFF position ■ □ 62/90/120 140 81.6 0.9 1.2 1.7 IP40 IP20 Front/Rear □ — □ — ON/OFF position ■ □ 70/105/140 157 91.5 1.2 1.7 2.2 only Ex9M1,Ex9M2 have 2P. Note①:Rated current of electronic MCCB, rated current of electronic Ex9M2 is 250A, 160A, 100A, 63A and 32A. P Ex9M3M Ex9M4M Ex9M5M 3P/4P 400 3P/4P 630 3P/4P 800 S N 50/60 380/400/415/660/690 250-315-350-400① 800 8 Q R H V P S 50/60 380/400/415/660/690 400-500-630① 800 8 N Q R H V 36 50 70 85 100 120 150 36 50 70 10 10 10 10 100% 50% ■ A 10000 4000 2000 1000 12 12 15 10 10 10 — — (9-10-11-12-13-14)×In — (1.5~14)×In P S 50/60 380/400/415/660/690 630-700-800① 800 8 N Q R H V 100 120 150 36 50 70 85 100 120 150 10 12 100% 100% ■ A 10000 4000 2000 1000 12 15 10 10 10 10 100% 100% ■ A 5000 2500 1000 500 12 12 15 85 RCD3(0.05A-0.2A-0.5A-1A Adjustable;RCD4(0.1A-0.3A-1A-2A Adjustable) — — (9-10-11-12-13-14)×In — (1.5~14)×In — — — (9-10-11-12-13-14)×In — (1.5~14)×In — □ □ □ □ □ □ □ □ □ □ □ □ □ □ □ □ □ □ □ □ □ IP40 IP20 Front/Rear □ □ □ — ON/OFF position ■ □ 140/185 255 118.5 — 5.0 6.6 IP40 IP20 Front/Rear — □ □ — ON/OFF position ■ □ 195/260 300 142 — 10.2 13.5 IP40 IP20 Front/Rear — □ □ — ON/OFF position ■ □ 195/260 300 142 — 10.2 13.5 P 11 Parameter Ex9M Series Switch Disconnector Ex9M1SD Ex9M2SD 2P/3P/4P 2P/3P/4P 125 250 50/60 380/400/415/660/690 500/750/1000 125 125 1000 8 1800 1800 700 ■ AC22A/AC23A DC22A/DC23A 15000 7000 5000 1000 50/60 380/400/415/660/690 500/750/1000 250 250 1000 8 3200 3200 1350 ■ AC22A/AC23A DC22A/DC23A 15000 7000 5000 1000 □ □ □ □ □ □ □ □ □ □ □ □ □ □ IP40 IP20 Front/Rear □ — □ — ON/OFF position ■ □ 62/90/120 140 81.6 0.6 1.0 1.5 IP40 IP20 Front/Rear □ — □ — ON/OFF position ■ □ 70/105/140 157 91.5 1.1 1.5 2.0 Switch disconnector Number of poles Rated frame current (A) Electric performance Working frequency(Hz) f AC DC AC DC Rated operational voltage (V)Ue Rated working current(A) In Rated insulation voltage(V) Rated impulse withstand voltage Rated shorttime withstand current (A) Ui Uimp 1s 3s 20s (A) Isolation function AC DC Actual mean value Test value Actual mean value Test value Load type Service life (C-O) Mechanical Electrical Control and indication Control mode Direct(RHD) Extended(ERH) Manual Motor mechanism(MOD) Shunt release(SHT) Under-voltage release(UVT) Auxiliary contact(AX) Alarm contact(AL) Connection and installation All sides Degree of protection Wiring terminal Wiring assembly Wiring Plug-in base(PIA) Draw-out base(DOB) Front Terminal shield(TCV) Rear Handle lock(KLK) Phase board(PHS) Mechanical interlock(MIT) a(2*/3/4) b c External dimensions (mm) W×H×D Weight (Kg) (Fixed before connection) ■ Yes 12 □Optional — No 2P 3P 4P Ex9M1SD, Ex9M2SD have 2 P; 500V for 2 poles in series connection, 750V for 3 poles in series connection, * Only 1000V for 4 poles in series connection Ex9M3SD Ex9M4SD Ex9M5SD 3P/4P 3P/4P 3P/4P 400 630 800 50/60 380/400/415/660/690 750/1000 400 400 1000 8 5000 5000 2400 ■ AC22A/AC23A DC22A/DC23A 10000 4000 2000 1000 50/60 380/400/415/660/690 750/1000 630 630 1000 8 8000 8000 3000 ■ AC22A/AC23A DC22A/DC23A 5000 4000 2000 1000 50/60 380/400/415/660/690 750/1000 800 800 1000 8 10000 10000 3800 ■ AC22A/AC23A DC22A/DC23A 5000 2500 2000 500 □ □ □ □ □ □ □ □ □ □ □ □ □ □ □ □ □ □ □ □ □ IP40 IP20 Front/Rear □ □ □ — ON/OFF position ■ □ 140/185 255 118.5 — 4.5 6.0 IP40 IP20 Front/Rear — □ □ — ON/OFF position ■ □ 195/260 300 142 — 9.5 12.7 IP40 IP20 Front/Rear — □ □ — ON/OFF position ■ □ 195/260 300 142 — 9.5 12.7 13 Parameter Ex9MD Series DC Circuit Breaker Ex9MD1 Ex9MD2 For PV system Number of poles 2P/3P/4P 2P/3P/4P Rated frame current (A) 125 250 Electric performance Rated working voltage (V) Ue 500/750/1000 500/750/1000 Rated current (A) In 16-20-25-32-40-50-63-80-100-125 125-160-180-200-225-250 Rated insulation voltage (V) Ui 1000 1000 Rated impulse withstand voltage (kV) Uimp 8 8 Type of breaking B S N Q R H B S N Q R Ultimate breaking capacity (kA) Icu 1000V DC 25 36 50 70 85 100 25 36 50 70 85 Service breaking capacity (% Icu) Ics 100% 100% ■ ■ Isolation function Utilization category A A Actual mean value 15000 15000 Mechanical Test value 7000 7000 Service life (C-O cycle) Actual mean value 5000 5000 Electrical Test value 1000 1000 Protection Long-time delay (0.8-0.9-1.0)×In (0.8-0.9-1.0)×In Short-time delay — — Thermomagnetic Instantaneous 10×In (5-6-7-8-9-10)×In Control and indication □ □ Direct(RHD) Manual Control □ □ Extended(ERH) mode □ □ Motor mechanism(MOD) □ □ Shunt release(SHT) □ □ Under-voltage release(UVT) □ □ Auxiliary contact(AX) □ □ Alarm contact(AL) Connection and installation All sides IP40 IP40 Degree of protection Wiring terminal IP20 IP20 Wiring assembly Front/rear Front/rear □ □ Wiring Plug-in base(PIA) — — Draw-out base(DOB) ■ ■ Shorted row(DCB) Handle lock(KLK) ON/OFF position ON/OFF position ■ ■ Phase board(PHS) □ □ Mechanical interlock(MIT) a c a(2*/3/4) 62/90/120 70/105/140 External dimensions (mm) b 140 157 b W×H×D c 81.6 91.5 2P 0.9 1.2 Weight (kg) 3P 1.2 1.7 (Fixed before connection) 4P 1.7 2.2 Only Ex9MD1 Ex9MD2 have 2 P; 500V for 2 poles in series connection, 750V for 3 poles in series □Optional ■YES — NO *connection, 1000V for 4 poles in series connection 14 H 100 B 25 S 36 Ex9MD3 Ex9MD4 Ex9MD5 3P/4P 400 3P/4P 630 3P/4P 800 750/1000 250-315-350-400 1000 8 N Q 50 70 100% ■ A 10000 4000 2000 1000 750/1000 400-500-630 1000 8 N Q 50 70 100% ■ A 10000 4000 2000 1000 750/1000 630-700-800 1000 8 N Q 50 70 100% ■ A 5000 2500 1000 500 R 85 H 100 B 25 S 36 R 85 H 100 B 25 S 36 (0.8-0.9-1.0)×In — (5-6-7-8-9-10)×In (0.8-0.9-1.0)×In — (5-6-7-8-9-10)×In (0.8-0.9-1.0)×In — (5-6-7-8-9-10)×In □ □ □ □ □ □ □ □ □ □ □ □ □ □ □ □ □ □ □ □ □ IP40 IP20 Front/rear □ □ ■ ON/OFF position ■ □ 140/185 255 118.5 — 5.0 6.6 IP40 IP20 Front/rear — □ ■ ON/OFF position ■ □ 195/260 300 142 — 10.2 13.5 IP40 IP20 Front/rear — □ ■ ON/OFFposition ■ □ 195/260 300 142 — 10.2 13.5 R 85 H 100 15 Accessories Ex9ML Residual Current Protection Module Standards IEC/EN 60947-2, Annex B; IEC60255-4 and IEC1-2~5,protection of over-voltage, lightning, electrostatic discharge and RFI interference POWER 0.05 0.2 0.5 2 I n(A) Power indicator Setting of Residual current Models Residual Current Time setting Ex9ML1 0.03-0.1-0.3-1(A) 0.05-0.2-0.5-2(A) Delayed 0.1-0.3-0.5-1(s) Ex9ML2 0.03-0.1-0.3-1(A) Ex9ML3 0.05-0.2-0.5-1(A) 0.1-0.2-1-3(A) maximum non-acting time△t(s):0/0.06/0.2/0.5(s) t(s):0/0.06/0.2/0.5 0.3 0.5 0.1 1 t(s) Time setting of delayed trip Note:Instantaneous trip under condition of residual current is set on 0.03A,0.1s. Accessory Alarm Contact (AL) Alarm Contact (AL) can be used together to make additional functions, which are either alarming without trip or alarming with trip. Note: This accessory shall be assembled by Noark 16 Accessories Internal Accessories 1 2 1 3 4 1 3 Auxiliary contact(AX) Shunt release(SHT) 【Function】 【Function】 Indication for the status of a circuit breaker (e.g. opening,closing) 【Type】 To control releasing of a circuit breaker remotely 【Type of power supply】 AC 400V AC 230V AC 110V AC 48V 1NO, 1NC 2 DC 220V DC 110V DC 48V DC 24V 4 Alarm contact(AL) Under-voltage release (UVT) 【Function】 【Function】 To send an alarm signal when the circuit breaker is released 【Type】 1 NO, 1 NC Under-voltage protection 【Type of power supply】 AC 400V AC 230V 17 Accessories External Accessories Direct rotary handle (DRH) Degree of protection : IP40,IK07 【The following functions can be ensured if a direct rotary handle is attached】 Reliable insulation Suitable for isolation function Free-releasing of a circuit breaker Indicator for three positions: ON/OFF/TRIP Not affecting the operations of release and “Release” test button by users 【Padlock】 The users may mount the padlock in the ON or OFF position (additional, diameter 5 - 8 mm) The number of padlocks for each position is 1 - 3 A handle lock is used to lock the circuit breaker in the ON or OFF position Extended rotary handle (ERH) Degree of protection: IP56, IK08 【If extended rotary handle mounted, operation of the circuit beakers could be realised outside the panel and the following function also could be realised】 Reliable insulation Suitable for isolation function Free-releasing of a circuit breaker Indicator for three positions: ON/OFF/TRIP When opening the door of the switch cabinet, tamper with the release and “Release” test button by users, ensuring that the circuit breaker does not turn on unnecessarily. 【LOCK】 The users may mount the padlock in the ON or OFF position (provided by themselves, diameter 5 - 8 mm) The number of padlocks for each position is 1 - 3 The attachment of a padlock will prevent the cabinet door from being opened A handle lock is used to lock the circuit breaker in the ON or OFF position 18 Accessories Motor mechanism(MOD) Degree of protection: IP40 【Functions】 Control the opening and closing of the circuit breaker through the button Accumulation of energy by the motor or the manual operating handle. With energy storage, opening & closing, and operational time indicators. Interface barrier (PHS) To improve the safety & insulation performance at the connection. Mechanical interlock (MIT) Used on a dual-circuit power system, ensuring the circuit breakers on both circuits will not close at the same time. Front installation. 19 Selection Ex9M Moulded Case Circuit Breaker Ex9M 1 S TM AC 125 3P Product Code Rated Frame Current Code Breaking Capacity Code Tripping device code AC/DC Code Rated Current (A) Poles Ex9M:AC Protection 1:125A B:25kA (DC) 125, 100, 80, 63, 50, 40, 32, 25, 20, 16 2P Ex9MD:DC Protection 2:250A S:36kA 250, 225, 200, 180, 160, 125 3P 3:400A N:50kA 400,350, 315,250 4P4T: Neutral protected, on-and -off 4:630A Q:70kA 630,500,400 5:800A R:85kA 800,700,630 TM: Thermomagnetic , for protection of general power distribution AC: Alternating current DC:Direct current M: Magnetic type, for motor protection H:100kA V:120kA P:150kA (AC) Example: “Ex9M1 S TM DC 125 3P”: means AC Moulded Case Circuit Breaker of the Ex9M series, frame current 125A, breaking capacity 36kA, 3 poles, rated current 125A with thermal-magnetic distribution protection trip unit. Note ①:2P only for Ex9M1, Ex9M2, Ex9MD1, Ex9MD2 2 :Special Product – Please contact NOARK before placing an order ① 20 4P4I: Neutral protected, without on-and -off ① 2 ① 2 ① 4P4U: Neutral unprotected, on-and -off 2 ① 4P4N: Neutral unprotected, without on-and -off 2 ① Selection Ex9M Moulded Case Circuit Breaker(Electronic type) Ex9M 2 S SU20S AC 250 3P Product Code Rated Frame Current Code Breaking Capacity Code Tripping device code AC/DC Code Rated Current (A) Poles Ex9M: AC Protection 2:250A S:36kA 250,160,100, 63,32 3P 3:400A N:50kA 4:630A Q:70kA 5:800A R:85kA SU20S: AC: alternating Basic electronic distribution protection current SU20C: Advanced electronic distribution protection ① SU20SM: 630 Basic electronic motor protection SU20CM: Advanced electronic motor protection 400 ① 800 H:100kA 4P4T: Neutral protected, on-and -off 4P4I: Neutral protected, without on-and -off ① ① 4P4U: Neutral unprotected, on-and -off ① 4P4N: Neutral unprotected, without on-and -off ① V:120kA P:150kA Example: Ex9M2S SU20S AC250 3P:Ex9M series MCCB, frame current 250A, breaking capacity 36kA, 3 poles, rated current 250A, with basic electronic distributon proctection trip unit Notes:COM21 communication module is needed to realize the communication between the Ex9M electronic circuit breaker and the upper computer, which could also realize the remote signal, remote adjustment and measurement. MOD motor mechanism is needed to realize the function of remote control. 21 Selection Ex9MSD Switch disconnector Ex9M 1 SD AC 3P Product Code Rated Frame Current Code Breaking Capacity AC/DC Code Poles 1:125A SD: Switch disconnector 2:250A 3:400A AC: alternating current DC: direct current 2P 3P 4P 4:630A 5:800A Example: Ex9M1SD DC 3P:means an Ex9MSD Switch disconnector,frame current 125A,DC,3 poles. 22 Selection Ex9ML Residual Current Protection Module Ex9ML 1 AC 125 3P A RCD1 Product Code Rated Frame Current Code AC/DC Code Rated Current (A) Poles Residual Current Type Code Rated Residual Operating Product Code Current Code Ex9ML: Residual Current Protection Module 1:125A 125,100,80,63, 50,40,32,25,20, 16 3P None: AC type RCD1: 0.03A-0.1A-0.3A-1A (Only to 9ML1, 9ML2) 2:250A 250,225,200, 180,160,125 4P A: A type RCD2:0.05A-0.2A-0.5A-2A (Only to 9ML1, 9ML2) 3:400A 400,350, 315,250 AC: alternating current RCD3:0.05A-0.2A-0.5A-1A (Only to 9ML3) RCD4:0.1A-0.3A-1A-2A (Only to 9ML3) Example: Ex9ML1 AC125 3P RCD1 stands for Ex9ML series AC Residual Current Protection Module, frame current 125A,3 poles,rated current 125A,and four adjustable grades of rated residual operating current: 0.05A-0.2A-0.5A-2A. Notes:The series standard delay time: four adjustable grades: 0.1S-0.3S-0.5S-1S. ELCB: For any order including Moulded Case Circuit Breaker and Residual Current Protection Module, it is approved to abbreviated two SKU codes as one SKU code. E.g.: The SKU codes of a Ex9M1 moulded case circuit breaker, 125A, 36KA, 3 poles, with thermal release, with leakage protection of four adjusted grades: 0.03A-0.1A-0.3A-1A are:Ex9M1 S TM AC 125 3P and Ex9ML1 AC125 3P RCD1,can be abbreviated as Ex9M1 S TM AC125 3P RCD1. 23 Selection Ex9M Series Products Accessories voltage AC24V、AC48V AC110VA、C220V AC230V、AC240V AC380V、AC400V AC415V、AC660V AC690V、AC24V DC48V、DC110V DC120V、DC220V SHT 22 Accessories code Rated Frame Current Code Details refer to the following list Details as per attached list AC110V 3P OTHER Voltage Poles None for no working voltage None Special request code 3P 4P None Special request code Selection example: SHT 22 AC110V:shunt release for 9M2, with control voltage of AC110V RHD 23:direct rotary handle for 9M3 Accessories 24 Name Specification Auxiliary contact Alarm contact Shunt release Under-voltage release Direct rotary handle Extended rotary handle Motor mechanism Handle lock Mechanical interlock Terminal shield Extended terminal shield Rear connection plate Draw-out base Plug-in base Din-rail adaptor AX AL SHT UVT RHD ERH MOD KLK MIT TCV 9M1 9M2 9M3 9M4 9M5 SHT21 UVT21 RHD21 ERH21 MOD21 KLK21 MIT21 TCV21 SHT21 ERH22 MOD22 KLK22 MIT22 TCV22 RHD23 ERH23 MOD23 KLK23 MIT23 TCV23 RHD24 ERH24 MOD24 KLK24 MIT24 TCV24 TCE TCE21 TCE22 TCE23 TCE24 RCP DOB PIA DRA RCP21 — PIA21 DRA21 RCP22 — PIA22 DRA22 RCP23 DOB23 PIA23 — Front panel escutcheon CDP CDP21 CDP22 CDP23 Communication module Battery module ■YES □ Optional COM BAB — NO AX21 AL21 SHT22 UVT22 RCP24 DOB24 — — COM21(Used for 9M electronic type) BAB21(Used for 9M electronic type) RCP25 DOB25 — — CDP24 25