Molded Case Circuit Breakers L-Frame Thermal

Molded Case Circuit
Breakers
L-Frame Thermal-Magnetic Circuit Breakers
Class 600, 665, 736, 830
www.schneider-electric.us
Table 7.129:
L-Frame—400 A, Thermal-Magnetic Circuit Breakers, 600 Vac
Adjustable AC
Magnetic Trip
Ampere
Rating
LAL/LHL
2P and 3P
125–400 A
Low
2P, 600 Vac, 250 Vdc
125 A
625 A
150 A
750 A
175 A
875 A
200 A
1000 A
225 A
1125 A
250 A
1250 A
300 A
1500 A
350 A
1750 A
400 A
2000 A
3P, 600 Vac, 250 Vdc
125 A
625 A
150 A
750 A
175 A
875 A
200 A
1000 A
225 A
1125 A
250 A
1250 A
300 A
1500 A
350 A
1750 A
400 A
2000 A
Table 7.130:
High Interrupting
$ Price
Cat. No.
Terminal
Wire Range
Cat. No.
$ Price
1250 A
1500 A
1750 A
2000 A
2250 A
2500 A
3000 A
3500 A
4000 A
LAL26125
LAL26150
LAL26175
LAL26200
LAL26225
LAL26250
LAL26300
LAL26350
LAL26400
3807.00
3807.00
3807.00
3807.00
3807.00
3807.00
3807.00
3807.00
3807.00
LHL26125
LHL26150
LHL26175
LHL26200
LHL26225
LHL26250
LHL26300
LHL26350
LHL26400
6362.00
6362.00
6362.00
6362.00
6362.00
6362.00
6362.00
6362.00
6362.00
AL400LA
(1) 1 AWG–600 kcmil Al
or
(2) 1 AWG–250 kcmil Al
1250 A
1500 A
1750 A
2000 A
2250 A
2500 A
3000 A
3500 A
4000 A
LAL36125
LAL36150
LAL36175
LAL36200
LAL36225
LAL36250
LAL36300
LAL36350
LAL36400
4619.00
4619.00
4619.00
4619.00
4619.00
4619.00
4619.00
4619.00
4619.00
LHL36125
LHL36150
LHL36175
LHL36200
LHL36225
LHL36250
LHL36300
LHL36350
LHL36400
7598.00
7598.00
7598.00
7598.00
7598.00
7598.00
7598.00
7598.00
7598.00
AL400LA
(1) 1 AWG–600 kcmil Al
or
(2) 1 AWG–250 kcmil Al
L-Frame—600 A, Extra-High Interrupting and Current-Limiting Circuit Breakers, 600 Vacb
Adjustable AC
Magnetic Trip
Ampere
Rating
LIL36600
2P and 3P 300–600 A
Standard Interrupting
High
Low
Extra-High Interrupting
High
Cat. No.
$ Price
Current Limiting
Cat. No.
Terminal
Wire Range
$ Price
2P, 600 Vac
300 A
1500 A
3200 A
LCL26300
7479.00
LIL26300
8604.00
350 A
1750 A
3200 A
LCL26350
7479.00
LIL26350
8604.00
400 A
2000 A
3200 A
LCL26400
7479.00
LIL26400
8604.00
450 A
2250 A
4200 A
LCL26450
7823.00
LIL26450
12551.00
500 A
2500 A
4200 A
LCL26500
7823.00
LIL26500
12551.00
600 A
3000 A
4200 A
LCL26600
7823.00
LIL26600
12551.00
3P, 600 Vac
300 A
1500 A
3200 A
LCL36300
8312.00
LIL36300
9563.00
350 A
1750 A
3200 A
LCL36350
8312.00
LIL36350
9563.00
400 A
2000 A
3200 A
LCL36400
8312.00
LIL36400
9563.00
450 A
2250 A
4200 A
LCL36450
8691.00
LIL36450
13949.00
500 A
2500 A
4200 A
LCL36500
8691.00
LIL36500
13949.00
600 A
3000 A
4200 A
LCL36600
8691.00
LIL36600
13949.00
b
Type LC, LI, LX, LXI, and LE circuit breakers are NOT recommended for use on single motor branch circuits.
AL600LI5
(2) 4/0 AWG–500 kcmil Al
AL600LI5
(2) 4/0 AWG–500 kcmil Al
Table 7.131:
Mechanical Lug Kit Information
Circuit Breaker Application
AL400LA
AL600LI5
(Number of Wires Per Lug)
Wire Range
Standard
Ampere
Rating
Optional
Ampere
Rating
LA, LH
125–400 A
—
—
—
LE, LX, LXI
LI, LE, LX, LXI, LC
—
—
100–250 A
300–600 A
—
LA, LH
LC, LI, LE, LX, LXI
LE, LX, LXI
LI, LE, LX, LXI, LC
125–400 A
—
100–250 A
—
—
—
LA, LH
125–400 A
—
—
—
—
—
—
LI, LE, LX, LXI, LC
LI, LE, LX, LXI, LC
LI, LE, LX, LXI, LC
—
—
—
(1) 1 AWG–600 kcmil Al or Cu or
(2) 1 AWG–250 kcmil Al or Cu
(1) 350–750 kcmil Al or Cu
(2) 1 AWG–350 kcmil Al or Cu
(2) 4/0 AWG–500 kcmil Al or Cu
(1) 500–750 kcmil Al or Cu
(1) 1 AWG–600 kcmil Cu or
(2) 1 AWG–250 kcmil Cu
(2) 1 AWG–350 kcmil Cu
(2) 4/0 AWG–500 kcmil Cu
(1) 500–750 kcmil Cu
Cat. No.
Lugs
Per
Kit
AL400LA
1
35.70
AL400LH7
AL600LI35
AL600LI5
AL600LI7
1
1
1
1
47.10
53.00
47.10
53.00
$ Price
Per Kit
CU400LA
1
70.00
CU600LI35
CU600LI5
CU600LI7
1
1
1
230.00
230.00
230.00
NOTE: Consider using PowerPact® circuit breakers for situations requiring circuit breaker accessories.
Table 7.132:
7
AL400LH7
Interrupting Table
LAL
LHL
LCL
LIL
240 Vac
42 kA
65 kA
100 kA
200 kA
480 Vac
30 kA
35 kA
65 kA
200 kA
600 Vac
22 kA
25 kA
35 kA
100 kA
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Supplemental Digest
Compression and Power Distribution Connector Lugs . Supplemental Digest
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 7-54
Enclosures. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 7-56
© 2009 Schneider Electric
All Rights Reserved
MINIATURE AND MOLDED CASE
CIRCUIT BREAKERS
NOTE: For LA Mission Critical circuit breakers, see Table 7.77.
DE2
Discount
Schedule
7-51
Selection Information
Molded Case Circuit Breaker
Class 500, 600, 800
www.schneider-electric.us
250 A K-Frame
Circuit Breaker Type
Number of Poles
Current Range
PowerPact 400/600 A D-Frame
400 A L-Frame
600 A L-Frame
KI
DG
DJ
DL
Q4
LA
LH
LC
LI
2, 3
3, 4
3, 4
3, 4
2,3
2,3
2, 3
2, 3
2, 3
110–250
150–600
150–600
150–600
250–400
125–400
125–400
300–600
300–600
200
Interrupting Ratings
UL/CSA/NOM
Rating
(kA RMS)
(50/60 Hz)
240 Vac
200
65
100
150
25
42
65
100
480Y/277 Vac
200
35
65
100
—
30
35
65
200
480 Vac
200
35
65
100
—
30
35
65
200
600Y/347 Vac
100
18
25
25
—
22
25
35
100
600 Vac
100
18
25
25
—
22
25
35
100
250 Vdc
—
—
—
—
—
10
50
—
—
500 Vdca
—
—
—
—
—
—
20
—
—
240 Vac
—
85/85
100/100
150/150
—
—
—
—
—
415 Vac
130/65
For additional IEC ratings, see
the Supplemental Digest.
45/45
70/70
150/150
—
20/5
20/5
65/65f
—
Fed. Specs W-C-375B/GEN
X
—
—
—
X
X
X
X
X
HACR (2P, 3P)
—
X
X
X
—
X
X
—
—
X
DC Ratings
IEC 60947-2
(kA RMS)
Icu/lcsb
IEC 50/60 Hz
For additional IEC ratings, see the Supplemental Digest.
Special Ratings
Connections/Terminations
7
Unit Mount
X
X
X
X
X
X
X
X
I-Line®
X
—
—
—
X
X
X
X
X
Rear Connection
—
X
X
X
X
X
X
—
—
Drawout
—
X
X
X
—
—
—
—
—
Optional Lugs
X
X
X
X
X
X
X
X
X
X
Accessories and Modifications
MINIATURE AND MOLDED CASE
CIRCUIT BREAKERS
Shunt Trip
Xc
X
X
X
X
X
X
X
Undervoltage Trip
Xc
X
X
X
X
X
X
X
X
Auxiliary Switches
Xc
X
X
X
X
X
X
X
X
Alarm Switch
Xc
X
X
X
X
X
X
X
X
Motor Operator
X
X
X
X
X
X
X
—
—
Handle Operators
—
X
X
X
X
X
X
—
—
Mechanical Interlocks (3P)
—
X
X
X
—
Xd
Xd
—
—
Handle Padlock Attachment
X
X
X
X
X
X
X
X
X
Cylinder Lock (3P)
—
—
—
—
X
X
X
—
—
Optional GF Protection
Xe
X
X
X
—
—
—
—
—
Thermal-magnetic
X
—
—
—
X
X
X
X
X
Instantaneous-only (MCP)
—
X
X
X
—
X
X
—
—
Trip System Type
Molded Case Switch (Automatic)
—
X
X
X
—
—
X
—
—
Electronic
—
X
X
X
—
—
—
—
—
General Purpose (NEMA 1)
—
—
—
—
X
X
X
—
—
Raintight (NEMA 3R)
X
—
—
—
X
X
X
—
—
Dust-tight (NEMA 12)
X
—
—
—
X
X
X
X
X
Watertight (NEMA 4, 4X, 5)
X
—
—
—
X
X
X
—
—
—
—
—
—
—
—
—
—
Enclosures (Pages 7-56–7-58)
Explosion Proof (NEMA 7, 9)
Dimensions
(3P Unit Mount)
in. (mm)
Height
8 (203)
13.38 (340)
Width
4.5 (114)
5.51 (140)
4.75 (121)
4.33 (110)
Pages
Pages (Unit Mount)/(I-Line)
Pages
7-25/7-33
7-49/9-26
Note: All circuit breakers on this chart are UL Listed and CSA Certified unless otherwise noted.
a
Ungrounded UPS systems only. See page 7-34.
b
Dual UL and IEC ratings and CE markings on circuit breakers. For additional IEC ratings, see the Supplemental Digest.
c
Factory-installed option only.
d
Requires circuit breaker with WB suffix .
e
Requires factory-installed “G” Shunt trip. Available only for 3P.
f
65/50 kA Icu/Ics for 450 A–600 A ratings
7-6
Depth
11 (279)
—
11.86 (301)
6 (152)
7.5 (190)
5.84 (148)
6.74 (171)
Pages 7-51/9-27
Pages 7-51/9-27
© 2009 Schneider Electric
All Rights Reserved
Dimensions and Shipping Weights
Miniature and Molded Case Circuit Breakers
www.schneider-electric.us
A
G
A
G
A
G
Table 7.140:
D
C
QO®, QOU, Multi 9TM Circuit Breakers
Circuit Breaker
Cat. No. Prefix
B E
B E
B E
Figure 1
Figure 3
Figure 2
A
G
A
G
B
A
G
A
G
QO-GFI, QO-PL
QO-EPD
Figure 5
Figure 4
A
G
B E
Figure 6
D
C
E
E
B
B E
QO, QOB
D
C
F
B E
Figure 7
QOU, QYU
Low Ampere
Figure 8
A
D
C
A
A
B
Figure 9
QO-PLPS
Circuit Breaker
Cat. No. Prefix
B E
Figure 10
Figure 11
Figure 12
7
D
A
A
MINIATURE AND MOLDED CASE
CIRCUIT BREAKERS
B
B
A
A
B
B
Figure 13
Figure 14
Figure 15
A
A
A
C
E
Figure 16
B
Figure 17
E
B
B
Figure 18
B
G
C
B E
B
Figure 19
Figure 20
C120
B
E
B
G
HH
F
G
—
—
—
—
—
—
—
—
5.00d
5.00d
5.00f
6.78
6.78
6.78
—
—
—
—
—
0.59
1.34
2.09
2.85
4.35
0.59
1.34
2.09
0.62
1.37
2.12
—
—
—
—
—
—
—
—
QB, QD, QG, QJ, Q4, FA, FI, KA, KC, KI, LA, LC, LI,
LE, LX, LXI, MA Circuit Breakers
Dimensions—Inches
D
E
F
G
H
2
3
1
2
3
22
23
21
22
23
6.47
6.47
6.00
6.00
6.00
3.00
4.50
1.50
3.00
4.50
3.02
3.02
3.16
3.16
3.16
3.93
3.93
4.13
4.13
4.13
g
g
0.44
0.44
0.44
4.25
4.25
5.13
5.13
5.13
—
1.50
1.50
—
1.50
—
0.75
—
—
0.75
FIL, KAL, KCL,
2&3
23
8.00
4.50
3.66 4.75 0.44
KHL, KIL
Q4L, LAL, LHL
2&3
23
11.00 6.00
4.06 5.84 0.88
LIL, LEL, LXL, LXIL, 2 & 3
24
11.86 7.50
5.48 6.74 0.55
LCL
MAL, MHL
2&3
23
14.00 9.00
4.53 6.50 1.66
g
Dimensions E are 1.59 in at ON end and 0.63 in at OFF end.
7.13
1.50
0.75
9.25
2.00
1.00
10.75
2.50
10.69
3.00
Frame Size
1.50
Shipping Weightsh
Approx. Shipping
Weight (Lbs.)
Approx. Shipping
Weight (Lbs.)
Frame Size
FAL, FHL 1P
2
KIL
9
FAL, FHL 2P
3
LAL, LHL
15
FAL, FHL 3P
5
LEL, LIL, LXL, LXIL, LCL
25
FIL
8
Q4L
15
QB, QD, QG, QJ
4
MAL, MHL
34
KAL, KHL
7
h
E
E
2.25
2.25
2.25
3.78
3.78
2.25
2.25
2.25
2.25
2.25
2.25
2.25
2.25
2.25
1.77
1.77
1.77
1.77
—
C
C60
D
D
B
Table 7.142:
A
C
A
FAL, FHL
QOU
High Ampere
B
Fig.
No.
B F
B E
A
Poles
QB, QD,
QG, QJ
B E
Dimensions—Inches
Fig.
No.
1
1
0.75 3.00a 2.31
2.91
QO, QOB
2
2
1.50 3.00a 2.31
2.91
3
3
2.25 3.00a 2.31
2.91
2
2
3.0
5.72
2.53
4.90
QOB-VH 150 A
QOB-VH 110–150 A
3
3
4.50
5.72
2.53
4.90
1
4
0.75 4.12b 2.31
2.91
QO-PL
QO-GFI
2
5
1.50 4.12b 2.31
2.91
QO-EPD
3
5
2.25 4.12b 2.31
2.91
1
6
0.75 4.05c 2.38
2.98
QOU
QYU
2
7
1.50 4.05c 2.38
2.98
Low Ampere
3
8
2.25 4.05d 2.38
2.98
1
10
0.75
4.45
2.37
2.96
QOU
2
11
1.50
4.45
2.37
2.96
High Ampere
3
12
2.25
4.45
2.37
2.96
1
13
0.71
3.19
1.73
2.76
2
14
1.42
3.19
1.73
2.76
Multi 9™ C60N
3
15
2.13
3.19
1.73
2.76
4
16
2.84
3.19
1.73
2.76
QO-PLPS Power Supply
2
9
1.45
4.35
2.42
3.11
a
35–70 A is 3.12 in; 80–100 A 2P and 70–100 A 3P are 3.50 in.
b
QO-PL is 4.55 in.
c
80–100 A 1P and 80–125 A 2P are 4.45 in
d
80–100 A 1P and 80–125 A 2P are 6.78 in.
e
70–100 A 4.45 in.
f
70–100 A is 6.78 in.
Table 7.141:
D
C
A
Poles
All weights are for 3P circuit breakers unless otherwise noted.
D
C
C/L
A F
C/L
A F
A F
E
E
Figure 21
Figure 22
B
G
E
D
C
Figure 23
E
A F
E
Figure 24
7-54
© 2009 Schneider Electric
All Rights Reserved
Special Construction
Square D
Class 690
www.squared.com
FOR CURRENT INFORMATION
Special Magnetic or Thermal Calibration (20% Price Adder)
Magnetic:
The magnetic trip ranges for standard circuit breakers are listed in the Square D Digest. Requirements outside this range are best accommodated by
selecting another standard circuit breaker. In some cases where this is not practical, a circuit breaker may be ordered with special magnetic calibration.
Special magnetic calibration is not possible in all cases. Circuit breakers with special magnetic calibration and an adjustable magnetic trip range are not
UL Listed; those with a fixed magnetic trip setting are UL Listed. Consult Square D/Schneider Electric sales office for more information.
50 Degrees C:
UL 489 Listed molded case circuit breakers are calibrated for 40 degree C ambient temperature. To meet requirements of higher ambient conditions,
circuit breakers can be factory calibrated for a 50 degree C ambient temperature. Circuit breakers with special thermal calibration are not UL Listed. To
order, place the suffix "35" after the catalog number (e.g., KAL36225-35). No other special thermal calibrations are available.
Visi-blade Circuit Breakers (20% Price Adder)
Visi-blade construction is a modification to the cover of a thermalmagnetic circuit breaker, a molded case switch, or a MAG-GARD® circuit
breaker which provides a "window" through which the position of the
movable contacts can be verified. Luminescent paint is applied to the
movable contact arms to clearly indicate their position. Gases produced
during high level interruption may cause clouding of the Visi-blade
window. Visi-blade circuit breakers listed below are UL Listed except for
FH circuit breakers. Visi-blade construction is not available on circuit
breakers not included in table below.
Add suffix letter 'V to the circuit breaker catalog number, i.e., FAL
36100V.
Available Visi-blade Circuit Breakers
Circuit Breaker Prefix
Amperes
FA, FH*
15-100
Price
KA, KH
70-250
20%
LA, LH
125-400
Price Adder
MA, MH
Visi-blade Circuit Breaker
300-1000"
• FH circuit breaker is not UL Listed.
• I-LINE® 800 A maximum, unit mount 1000A maximum.
Moisture and Fungus Resistant Treatment for Circuit Breakers (20% Price Adder)
This treatment covers the application of moisture and fungus resistant varnish to circuit breakers and molded case switches.
• The varnish meets Military Specification MIL-V-173C VARNISH, MOISTURE AND FUNGUS RESISTANT.
• The treatment meets military Specification MIL-T-152E TREATMENT, MOISTURE AND FUNGUS-RESISTANT, OF COMMUNICATIONS, ELECTRONIC, AND ASSOCIATED ELECTRICAL EQUIPMENT.
The treatment of circuit breakers in accordance with said specifications is intended to protect them against the moisture and fungus condition encountered in service by retarding the absorption of moisture and inhibiting the growth of fungi.
To order, place the suffix "FT" at the end of the circuit breaker catalog number, e.g., FAL36100 becomes FAL36100FT.
This treatment is not available on KD circuit breakers.
EDB, FDA, and GJL circuit breakers are inherently fungus resistant and need no further treatment.
Short Handle for LA/LH Circuit Breakers (No Additional Charge)
Certain applications of the LA/LH circuit breakers (as mains in particular panelboards) require the use of a slightly shorter operating handle. For ordering
information refer to the chart below.
Catalog Numbers for Short Handle LA/LH Circuit Breakers
Lug Configuration Desired
ON End
OFF End
Catalog
"Prefix Indication"
Catalog
"Suffix Indication"
Circuit Breaker
Catalog Number
Lugs
Lugs
"L'
"MB"
LAL36400MB
No Lugs
Lugs
"P"
"MB"
LAP36400MB
Lugs
No Lugs
"P"
"MT'
LAP36400MT
No Lugs
No Lugs
"F
"MB"
LAF36400MB
MAG-GARD and I-LINE are Registered Trademarks of Square D Company or related companies.
3/00
DE2
Discount
Schedule
5-9