NOTES SAMPLES OF ALL MATERIALS TO BE PROVIDED FOR CLIENT AND DESIGN TEAM APPROVAL IN ACCORDANCE WITH SAMPLES REGISTER SPECIFICATIONS 1. (H42/110) WET CAST CONCRETE / CAST STONE CLADDING SYSTEM BY TECHRETE OR EQUIVALENT WITH BRICK SLIP FINISH, REINFORCED ALL JOINTS TAPED TO FORM VAPOUR BARRIER. EPDM FLASHINGS & SEALS TO ADJOINING WORKS. TARGET U-VALUE 0.23W/m2K. 2. (H42/120) WET CAST CONCRETE / CAST STONE CLADDING SYSTEM BY TECHRETE OR EQUIVALENT ACID ETCHED PROFILED FINISH, ALL JOINTS TAPED TO FORM VAPOUR BARRIER. EPDM FLASHING & SEALS TO ALL ADJOINING WORK. TARGET U-VALUE 0.23W/m2K. 3. (H13/110) SINGLE GLAZED FRAMELESS DISPLAY WINDOW SYSTEM WITH LAMINATE GLASS FINS. EXTRA WHITE LOW IRON HEAT SOAKED GLASS (SGG DIAMANT OR EQUIVALENT) LAMINATED TO A THICKNESS OF 21.5mm TO SUIT OPENING SIZE. INCLUDING ALL STRUCTURAL GLASS FINS, SUPPORTS, POWDER COATED PERIMETER CHANNELS ON ENGINEERS DRAWINGS. ALL FIXINGS, SEALS FLASHINGS & INTERFACE DETAILS TO BE CONFIRMED BY MANUFACTURER. 4. (H11/110) PPC ALUMINIUM FRAMED CURTAIN WALLING SYSTEM: SCHUCO FW50+ OR EQUIVALENT WITH 37MM HIGH PERFORMANCE CLEAR DOUBLE GLAZED UNITS. GLAZING: SGG COOL-LITE SKN165 OR EQUIVALENT: 8mm TOUGHENED OUTER 16mm ARGON CAVITY, 12.8mm ANNEALED LAMINATE PLANITHERM ULTRA-N INNER PANE. FRAMEWORK & FLASHINGS POWDER COATED TO STANDARD RAL COLOUR (RAL 7043). MINIMUM TARGET U-VALUE: 1.1W/M2K (REGULATION L2A APPENDIX A). TRANSLUSCENT/ COLOURED GLAZING FILM WITH CUSTOMISED GRAPHIC. 5. (H11/120) CAPLESS PPC ALUMINIUM FRAMED CURTAIN WALLING SYSTEM: SCHUCO FW50+SG OR EQUIVALENT WITH 37MM HIGH PERFORMANCE CLEAR DOUBLE GLAZED UNITS. GLAZING: SGG COOL-LITE SKN165 OR EQUIVALENT: 8mm TOUGHENED OUTER 16mm ARGON CAVITY, 12.8mm ANNEALED LAMINATE PLANITHERM ULTRA-N INNER PANE. FRAMEWORK & FLASHINGS POWDER COATED TO STANDARD RAL COLOUR (RAL 7043). MINIMUM TARGET U-VALUE: 1.1W/M2K (REGULATION L2A APPENDIX A). ALLOW FOR TRANSLUSCENT GLAZING FILM WITH CUSTOMISED GRAPHIC. 6. (H43/120) PPC ALUMINIUM CILL ON PLASTICISED PVC WATERPROOF MEMBRANE (MIN 2MM THICK) BONDED TO EPDM FLASHING ON 12MM MARINE PLY LAID TO MIN 5 DEGREE FALL ON RIGID BOARD INSULATION. EPDM FLASHING GLAZED INTO WINDOW FRAME. ALLOW FOR BIRD DETERRENT SYSTEM (AVISHOCK OR EQUIVALENT) TO ALL HORIZONTAL LEDGES & CILLS. 7. (L20/490) STANDARD PRIMARK GLAZED ENTRANCE DOOR SYSTEM / SECURITY SHUTTERS / ACCESS CONTROL SYSTEMS. INGERSOLL RAND DOR-O-MATIC, ASTRO-BALANCE AUTODOOR OR EQUIVALENT. FAIL SAFE TO OPEN ON ACTIVATION OF FIRE ALARM. ALLOW PROVISIONAL SUM FOR ELECTRONIC LOCKS AND AUTOMATIC CLOSERS CONNECTED TO ALARM SYSTEM. 8. (L20/460) 12MM HST STRUCTURAL GLASS DOORS AND SIDE PANELS, BRUSHED STAINLESS STEEL PATCH FITTINGS, 2 POINT LOCKING, (BOTTOM AND MIDDLE) AND 300MM KICK PLATES. 9. (L10/670) ILLUMINATED SIGNAGE ON BLOCK VINYLED GLASS. ALLOW PLASTERBOARD BULKHEAD WITH ACCESS TO HOT AIR CURTAIN ABOVE ENTRANCE. 10. (F21/110A) 25MM NATURAL GRANITE SLAB AS MARSHALLS GRA 921 OR EQUIVALENT ON ADHESIVE GROUT ON 100MM ENGINEERING BRICK. (SEALANT & BEDDING TO DPC / DPM) 11. (K13/160B) INTERNAL BULKHEAD AND COLUMN SURROUND: 2x12.5MM PLASTERBOARD ON METAL STUD PAINT FINISH: GREY. COLOUR TBC. 12. (H13/120A) ENTRANCE FEATURES CLAD WITH COLOURED LAMINATE SUCH AS OKALUX OKACOLOUR / VANCEVA FOILED GLAZING BY SCHOTT UK LTD OR EQUIVALENT. WITH CONCEALED FIXINGS SUB-FRAMES, SUPPORTS, FIXINGS, COLOUR & ILLUMINATION EFFECTS TO BE CONFIRMED. 13. (H92/110A) PPC ALUMINIUM RAINSCREEN CASSETTE CLADDING SYSTEM BY CGL OR EQUIVALENT. 3MM THICK PANELS WITH ALL SUPPORT RAILS, BRACKETS, TOP HAT SECTIONS ANTI RATTLE GASKETS, BREATHER MEMBRANES AND CEMENTITIOUS BOARD TO PROVIDE 60 MIN FIRE RESISTANCE, 2 LAYERS OF 50MM KINGSPAN K15 KOOLTHERM INSULATION BETWEEN SUPPORT RAILS, AND SUB-FRAMES ON 100MM METSEC SFS, 2 LAYERS 12.5MM FOIL BACKED PLASTERBOARD TO FORM VAPOUR BARRIER. PANELS POWDER COATED TO STANDARD RAL COLOUR (TBC) TARGET U-VALUE 0.23W/m2K. 14. (H42/140) WET CAST CONCRETE / CAST STONE REVEAL PANELS BY TECHRETE OR EQUIVALENT ACID ETCHED SMOOTH FINISH, REINFORCED SEALS TO ADJOINING WORK. TARGET U-VALUE 0.23W/m2K. 15. (H42/150) GRC SOFFIT PANELS WITH CONCEALED FIXINGS ON S/S SUB FRAME. FINISH TO MATCH ACID ETCHED, REINFORCED CONCRETE CLADDING BY TECHRETE OR EQUIV. COLOUR TBC. EPDM FLASHING & SEALS TO ADJOINING WORKS. TARGET U-VALUE 0.23W/m2K. PROPRIETARY GLASS-MOUNTED SIGNAGE WITH ACRYLIC LETTERING TO OUTER FACE AND BUILT-IN ILLUMINATION TO INSIDE 15. (H42/150) GRC SOFFIT PANELS WITH CONCEALED FIXINGS ON S/S SUB FRAME. FINISH TO MATCH ACID ETCHED, REINFORCED CONCRETE CLADDING BY TECHRETE OR EQUIV. COLOUR TBC. EPDM FLASHING & SEALS TO ADJOINING WORKS. TARGET U-VALUE 0.23W/m2K. 16. (L10/680) PROPRIETARY GLASS-MOUNTED SIGNAGE WITH ACRYLIC LETTERING TO OUTER FACE AND BUILT-IN ILLUMINATION TO INSIDE FACE. BY WIDD SIGNS OR EQUIVALENT 17. (H92/120A) IAC NOISHIELD ACOUSTIC BARRIER. FS/A - 22.0, 127MM THICK. PPC ALUMINIUM FINISH. THE SCREEN SHOULD HAVE A MINIMUM 1. 2. DO NOT SCALE FROM THIS DRAWING DETAILS OF ANY EXISTING STRUCTURES HAVE BEEN REPRODUCED IN GOOD FAITH FROM ARCHIVE DRAWINGS AND SURVEY INFORMATION PROVIDED BY OTHERS 3. ALL DRAWINGS SHOULD BE READ IN CONJUNCTION WITH THE RELEVANT ARCHITECTURAL, STRUCTURAL, MECHANICAL & ELECTRICAL SPECIFICATION 4. ALL DIMENSIONS SHOWN ON THIS DRAWING ARE TO BE VERIFIED ON SITE BY THE CONTRACTOR PRIOR TO COMMENCEMENT OF MANUFACTURE 5. FOR ALL EXTERNAL BUILDING WORKS, GRADIENTS, DRAINAGE & SURFACING, REFER TO STRUCTURAL ENGINEER'S DRAWINGS 6. FOR DETAILS OF ALL PRIMARY, SECONDARY AND SUB STRUCTURES, REFER TO THE CONSULTANT STRUCTURAL ENGINEER 7. FOR DETAILS OF ALL MECHANICAL, ELECTRICAL & ABOVE GROUND DRAINAGE, REFER TO THE CONSULTANT ENGINEERS 8. PROPOSALS REMAIN SUBJECT TO PLANNING APPROVAL 9. PROPOSALS REMAIN SUBJECT TO BUILDING CONTROL APPROVAL 10. THIS DRAWING IS INTENDED TO OUTLINE DESIGN INTENT ONLY. THE DETAIL DESIGN OF ALL COMPONENTS IS TO BE AGREED WITH THE AGREED SUPPLIER IN ACCORDANCE WITH THE PROFILES SHOWN ON THE DRAWING AND THE PERFORMANCE CRITERIA OUTLINED IN THE SPECIFICATION 11. THE DETAIL DESIGN OF ALL ELEMENTS THAT FORM PART OF THE CLADDING SYSTEM IS TO BE FINALISED BY THE SPECIALIST SUB-CONTRACTOR IN ACCORDANCE WITH THE REQUIREMENTS OF THE ARCHITECTURAL DRAWINGS AND SPECIFICATIONS 12. THE CONTRACTOR SHOULD DEVELOP AND CONFIRM PROPOSALS FOR CLEANING, MAINTENANCE AND REPLACEMENT OF ALL COMPONENTS IN ORDER TO SAFEGUARD THE SYSTEM WARRANTY. 13. PROPOSALS REMAIN SUBJECT TO CO-ORDINATION WITH FACADE LIGHTING, MAINTENANCE ACCESS AND BIRD DETERRENT SYSTEMS. 14. DETAILS OF ALL SUPPORT SYSTEMS, BRACKETS AND FIXINGS TO THE PRIMARY STRUCTURE ARE TO BE DEVELOPED IN ACCORDANCE WITH THE STRUCTURAL ENGINEER'S REQUIREMENTS. 15. THE CONTRACTOR IS TO ENSURE THAT ALL CLADDING SYSTEM INTERFACE DETAILS ARE CO-ORDINATED SO THAT THE RESULTING ENVELOPE CAN BE TESTED FOR COMPLIANCE WITH CWCT REQUIREMENTS FOR AIR TIGHTNESS AND INTEGRITY. 16. ALL PLASTERBOARD JOINTS TO BE TAPED AND SEALED. ALL JOINTS BETWEEN COMPONENTS TO BE ROBUSTLY SEALED IN ACCORDANCE WITH BSRIA RECOMMENDATIONS 17. NOTE: FINISHED FLOOR LEVELS TO BE CONFIRMED. EXISTING BUILDING. DRAWINGS TO BE ALIGNED WITH ORDNANCE SURVEY BENCHMARK AND TOPOGRAPHICAL SURVEY LEVELS * NB: FFL EXCLUDES NOM. 10MM ZONE FOR DECORATIVE FLOOR FINISHES 18. (L20/280A) STEEL FACED SOLID CORE TIMBER ESCAPE DOOR BY ARMOURPOST OR EQUIVALENT. POLYESTER POWDER COAT FINISH: STANDARD RAL COLOUR TBC. 19. (L20/610A) SECURITY SHUTTERS TO MAIN ENTRANCES BY: RING-GUARD UK OR EQUIVALENT: ALUMINIUM GRILLE, BRICK BOND PATTERN. ALUMINIUM FRAMING FITTED INTO REVEAL. SHUTTER FINISH: POLYESTER POWDER COATED, COLOUR RAL 9006. FRAME FINISH: POLYESTER POWDER COATED. COLOUR RAL 9006. 20. (L20/615A) INSULATED SECTIONAL UP AND OVER DOOR TO LOADING BAY BY KABA DOORS OR EQUIV STANDARD LIFT TRACK SYSTEM. DOOR PANEL GALVANISED STEEL INNER AND OUTER FACE INFILLED WITH HIGH DENSITY POLYURETHANE FOAM. STANDARD ENAMEL FINISH: RAL 9006. GALV STEEL FRAME/ GUIDES: ELECTRICAL OPERATION WITH EMERGENCY HAND CHAIN DOOR ASSEMBLY TO MEET MINIMUM TARGET U-VALUE OF 1.5W/m2K. DRAFT SEALS TO ALL EDGES AN OPENINGS. 21. (H42/---) PRECAST CONCRETE VERTICAL BRANDING INTEGRATED WITHIN PRECAST CONCRETE CLADDING. BY TECHRETE OR EQUIVALENT 22. NOT USED 23. (L10/450) INSULATED LOUVRE TO SMOKE EXTRACT SYSTEM AS COLT EN SEEFIRE WITH AUTOMATIC ACTUATOR AND FACTORY FITTED SECURITY GUARD. PPC FINISH COLOUR TBC 24.) SUB-STATION - IN ACCORDANCE WITH UK POWER NETWORKS REQUIRMENTS. REFER TO UTILITY SUPPLIERS DETAIL RECOMMENDATIONS. 25. (L10/470) STAINLESS STEEL ACCESS LADDER WITH HOOPED CAGE TO ACCESS ROOF PLANT AREAS (REFER TO MECHANICAL CONTRACTORS DRAWINGS FOR SCOPE OF BWICS) 26. STAINLESS STEEL DRY RISER INLET CABINET 27. STREET LIGHTING TO EDEN STREET TO BE MAINTAINED. REPLACE EXISTING FITTING TO HIGHWAYS AUTHORITY SPECIFICATION. DETAILS AND LOCATIONS TO BE AGREED WITH RBK 28. (L10/480) ARMCO BOLT DOWN BARRIER 29. (L10/490) SHEFFIELD STAINLESS STEEL BOLLARD 30. (H42/130) WET CAST CONCRETE / CAST STONE CLADDING SYSTEM BY TECHRETE OR EQUIVALENT WITH RECESSED SHADOW GAPS ACID VAPOUR BARRIER TO THE BACK OF THE INSULATION. TARGET U-VALUE 0.23W/m2K. 31. (H11/130) ALUMINIUM FRAMED NON-VISION DOUBLE GLAZED WINDOW SYSTEM SUCH AS SCHUCO FW50+ OR EQUIVALENT. FRAMEWORK & FLASHINGS PPC FINISH STANDARD RAL COLOUR (RAL 7043). OPAQUE COLOURED GLAZING FILM WITH CUSTOMISED GRAPHIC (COLOUR TBC) 8mm TOUGHENED OUTER 16mm ARGON CAVITY, 12.8mm TOUGHENED ARMOURCLAD LINING. TO ACHIEVE A MINIMUM U-VALUE OF 1.5W/M2K AS REGULATION L2A APPENDIX A. EXTENT OF VISION / NON-VISION WINDOWS SUBJECT TO CONFIRMATION OF RETAILING LAYOUTS BY PSL 32. EXISTING BRICKWORK RETAINED 33. (M21/210A) OUTSULATION BY DRYVIT OR EQUIVALENT. RENDER ON REINFORCED MESH EMBEDDED BASE COAT ON INSULATION BOARD (DEPTH TBC) ON 5MM DRYVIT GENESIS ADHESIVE DABS ON WATER RESISTIVE BARRIER COAT ON EXISTING EXTERNAL BRICKWORK. TARGET U-VALUE 0.23W/m2K. FINISH: SANDPEBBLE FINE. COLOUR TBC. 34. (M21/210B) OUTSULATION BY DRYVIT OR EQUIVALENT. RENDER ON REINFORCED MESH EMBEDDED BASE COAT ON 140MM EXPANDED POLYSTYRENE INSULATION BOARD ON DRYVIT ADHESIVE ON RCM Y WALL CEMENTITIOUS BOARD SUBSTRATE ON SFS FRAME. TARGET U-VALUE 0.23W/m2K . FINISH: SANDPEBBLE FINE. COLOUR TBC. 35. (M21/210C) OUTSULATION BY DRYVIT OR EQUIVALENT. RENDER ON REINFORCED MESH EMBEDDED BASE COAT ON INSULATION BOARD & DRYVIT ADHESIVE WATER RESISTIVE BARRIER COAT ON 100MM BLOCKWORK. TARGET U-VALUE 0.23W/m2K. FINISH: LIMESTONE. COLOUR TBC. 36. FACING BRICKWORK TO MATCH EXISTING (USE RETAINED BRICK WHERE POSSIBLE) ON 70MM KOOLTHERM K12 INSULATION WITH 50MM AIRSPACE ON 200MM METAL STUD ON VAPOUR BARRIER ON 2X12.5 MM WALLBOARD. TARGET U-VALUE 0.23W/m2K. 37. (L30/580A) FREESTANDING GALVANISED STEEL BARRIER TO ROOF: INCLINED VERSIRAIL BY LATCHWAY OR EQUIVALENT TO EN13374, EN ISO 14122-3 SECTION 8.2, EUROPEAN DIRECTIVE 2001/45/CE, BS6399; PART 2 1997, WORKING AT HEIGHT REGS 2005 38. (M21/210D) OUTSULATION BY DRYVIT OR EQUIVALENT. RENDER ON REINFORCED MESH EMBEDDED BASE COAT ON INSULATION BOARD (DEPTH TBC) ON 5MM DRYVIT GENESIS ADHESIVE DABS ON WATER RESISTIVE BARRIER COAT ON BRICK / BLOCK ON 70MM KOOLTHERM K12 INSULATION WITH 50MM AIRSPACE ON 200MM METAL STUD ON 2X12.5 MM WALLBOARD WITH VAPOUR BARRIER. TARGET U-VALUE 0.23W/m2K FINISH: LIMESTONE COLOUR TBC 39. GALVANISED STEEL ACCESS GATE WITH LATCH LOCK - EXISTING GATE TO BE SURVEYED, MADE GOOD AND RETAINED IF SUITABLE NUMBERS/UNITS INTEGRATED WITHIN WET CAST CONCRETE / CAST STONE CLADDING SYSTEM 29.528 29.010 13 37 26.127 25.575 FOURTH FLOOR 1:100 0 1 2 3 4 5 6 7 8 9 SPRINKLER ZONE KEY: 34 SITE BOUNDARY 21.600 THIRD FLOOR RETAIL AREAS 34 STOCK AREAS CASH & WRAP RETURNS STAFF AREAS RETAIL ANCILLARY AREAS PLANNING DO-NOT-USE-FOR-CONSTRUCTION CASH & WRAP FEMALE FITTING FEMALE FITTING RETAIL 50mm Dp RECESS TO BE FORMED LOCAL TO GLAZING BASE PLATE 130mm THK COMPOSITE FLOOR SLAB. SEE PLAN 130 12.525 FIRST FLOOR NEW SCREEN IN ACCORDANCE WITH ARCHITECT'S DETAILS SSL 12.525m 3.3 04.04.16 254 x 146 UB 610 x 305 UB 3.2 03.12.15 GLAZING HEAD RESTRAINT IN ACCORDANCE WITH SPECIALISTS DETAILS 20 SECTION 14 - 14 3.1 09.11.12 3.0 17.10.12 (SCALE 1=20) RETAIL ROOF PLANT AMENDED WITH NEW AHUS TO EU DIRECTIVE ROOF PLANT AMENDED, SECOND FLOOR RECESS ADDED, SUB-STATION INTAKE ADDED RETAIL CEILING HEIGHTS REVISED ISSUED FOR INFORMATION ONLY LM NDP LM NDP EMc EMc NDP NDP 9.285 CORR. CCTV EDEN STREET 7.975 GROUND FLOOR REFER TO STRUCTURAL ENGINEER'S DRAWINGS FOR EXISTING SUB STRUCTURE INFORMATION 7.975 GROUND FLOOR MALE FITTING ROOM REFER TO STRUCTURAL ENGINEER'S DRAWINGS FOR EXISTING SUB STRUCTURE INFORMATION 3.425 LOWER GROUND FLOOR PRIMARK EDEN STREET KINGSTON ON THAMES SECTION C-C 3DReid 36 North Castle Street Edinburgh EH2 3BN T 0131 225 4040 F 0131 225 4747 W www.3DReid.com 090486 1:100@A1 20.02.11 Dra 3DR 581 AR 9963 EM NdP 3.3 10