Plans

advertisement
NOTES
SAMPLES OF ALL MATERIALS TO BE PROVIDED FOR CLIENT AND DESIGN TEAM APPROVAL IN ACCORDANCE WITH SAMPLES REGISTER
SPECIFICATIONS
1. (H42/110) WET CAST CONCRETE / CAST STONE CLADDING SYSTEM BY TECHRETE OR EQUIVALENT WITH BRICK SLIP FINISH, REINFORCED
ALL JOINTS TAPED TO FORM VAPOUR BARRIER. EPDM FLASHINGS & SEALS TO ADJOINING WORKS. TARGET U-VALUE 0.23W/m2K.
2. (H42/120) WET CAST CONCRETE / CAST STONE CLADDING SYSTEM BY TECHRETE OR EQUIVALENT ACID ETCHED PROFILED FINISH,
ALL JOINTS TAPED TO FORM VAPOUR BARRIER. EPDM FLASHING & SEALS TO ALL ADJOINING WORK. TARGET U-VALUE 0.23W/m2K.
3. (H13/110) SINGLE GLAZED FRAMELESS DISPLAY WINDOW SYSTEM WITH LAMINATE GLASS FINS. EXTRA WHITE LOW IRON HEAT SOAKED
GLASS (SGG DIAMANT OR EQUIVALENT) LAMINATED TO A THICKNESS OF 21.5mm TO SUIT OPENING SIZE. INCLUDING ALL STRUCTURAL GLASS
FINS, SUPPORTS, POWDER COATED PERIMETER CHANNELS ON ENGINEERS DRAWINGS. ALL FIXINGS, SEALS FLASHINGS & INTERFACE DETAILS
TO BE CONFIRMED BY MANUFACTURER.
4. (H11/110) PPC ALUMINIUM FRAMED CURTAIN WALLING SYSTEM: SCHUCO FW50+ OR EQUIVALENT WITH 37MM HIGH PERFORMANCE CLEAR
DOUBLE GLAZED UNITS. GLAZING: SGG COOL-LITE SKN165 OR EQUIVALENT: 8mm TOUGHENED OUTER 16mm ARGON CAVITY, 12.8mm ANNEALED
LAMINATE PLANITHERM ULTRA-N INNER PANE. FRAMEWORK & FLASHINGS POWDER COATED TO STANDARD RAL COLOUR (RAL 7043). MINIMUM
TARGET U-VALUE: 1.1W/M2K (REGULATION L2A APPENDIX A). TRANSLUSCENT/ COLOURED GLAZING FILM WITH CUSTOMISED GRAPHIC.
5. (H11/120) CAPLESS PPC ALUMINIUM FRAMED CURTAIN WALLING SYSTEM: SCHUCO FW50+SG OR EQUIVALENT WITH 37MM HIGH
PERFORMANCE CLEAR DOUBLE GLAZED UNITS. GLAZING: SGG COOL-LITE SKN165 OR EQUIVALENT: 8mm TOUGHENED OUTER 16mm ARGON
CAVITY, 12.8mm ANNEALED LAMINATE PLANITHERM ULTRA-N INNER PANE. FRAMEWORK & FLASHINGS POWDER COATED TO STANDARD RAL
COLOUR (RAL 7043). MINIMUM TARGET U-VALUE: 1.1W/M2K (REGULATION L2A APPENDIX A). ALLOW FOR TRANSLUSCENT GLAZING FILM WITH
CUSTOMISED GRAPHIC.
6. (H43/120) PPC ALUMINIUM CILL ON PLASTICISED PVC WATERPROOF MEMBRANE (MIN 2MM THICK) BONDED TO EPDM FLASHING ON 12MM
MARINE PLY LAID TO MIN 5 DEGREE FALL ON RIGID BOARD INSULATION. EPDM FLASHING GLAZED INTO WINDOW FRAME. ALLOW FOR BIRD
DETERRENT SYSTEM (AVISHOCK OR EQUIVALENT) TO ALL HORIZONTAL LEDGES & CILLS.
7. (L20/490) STANDARD PRIMARK GLAZED ENTRANCE DOOR SYSTEM / SECURITY SHUTTERS / ACCESS CONTROL SYSTEMS. INGERSOLL RAND
DOR-O-MATIC, ASTRO-BALANCE AUTODOOR OR EQUIVALENT. FAIL SAFE TO OPEN ON ACTIVATION OF FIRE ALARM. ALLOW PROVISIONAL SUM
FOR ELECTRONIC LOCKS AND AUTOMATIC CLOSERS CONNECTED TO ALARM SYSTEM.
8. (L20/460) 12MM HST STRUCTURAL GLASS DOORS AND SIDE PANELS, BRUSHED STAINLESS STEEL PATCH FITTINGS, 2 POINT LOCKING,
(BOTTOM AND MIDDLE) AND 300MM KICK PLATES.
9. (L10/670) ILLUMINATED SIGNAGE ON BLOCK VINYLED GLASS. ALLOW PLASTERBOARD BULKHEAD WITH ACCESS TO HOT AIR CURTAIN ABOVE
ENTRANCE.
10. (F21/110A) 25MM NATURAL GRANITE SLAB AS MARSHALLS GRA 921 OR EQUIVALENT ON ADHESIVE GROUT ON 100MM ENGINEERING BRICK.
(SEALANT & BEDDING TO DPC / DPM)
11. (K13/160B) INTERNAL BULKHEAD AND COLUMN SURROUND: 2x12.5MM PLASTERBOARD ON METAL STUD PAINT FINISH: GREY. COLOUR TBC.
12. (H13/120A) ENTRANCE FEATURES CLAD WITH COLOURED LAMINATE SUCH AS OKALUX OKACOLOUR / VANCEVA FOILED GLAZING BY SCHOTT
UK LTD OR EQUIVALENT. WITH CONCEALED FIXINGS SUB-FRAMES, SUPPORTS, FIXINGS, COLOUR & ILLUMINATION EFFECTS TO BE CONFIRMED.
13. (H92/110A) PPC ALUMINIUM RAINSCREEN CASSETTE CLADDING SYSTEM BY CGL OR EQUIVALENT. 3MM THICK PANELS WITH ALL SUPPORT
RAILS, BRACKETS, TOP HAT SECTIONS ANTI RATTLE GASKETS, BREATHER MEMBRANES AND CEMENTITIOUS BOARD TO PROVIDE 60 MIN FIRE
RESISTANCE, 2 LAYERS OF 50MM KINGSPAN K15 KOOLTHERM INSULATION BETWEEN SUPPORT RAILS, AND SUB-FRAMES ON 100MM METSEC
SFS, 2 LAYERS 12.5MM FOIL BACKED PLASTERBOARD TO FORM VAPOUR BARRIER. PANELS POWDER COATED TO STANDARD RAL COLOUR
(TBC) TARGET U-VALUE 0.23W/m2K.
14. (H42/140) WET CAST CONCRETE / CAST STONE REVEAL PANELS BY TECHRETE OR EQUIVALENT ACID ETCHED SMOOTH FINISH, REINFORCED
SEALS TO ADJOINING WORK. TARGET U-VALUE 0.23W/m2K.
15. (H42/150) GRC SOFFIT PANELS WITH CONCEALED FIXINGS ON S/S SUB FRAME. FINISH TO MATCH ACID ETCHED, REINFORCED CONCRETE
CLADDING BY TECHRETE OR EQUIV. COLOUR TBC. EPDM FLASHING & SEALS TO ADJOINING WORKS. TARGET U-VALUE 0.23W/m2K.
PROPRIETARY GLASS-MOUNTED SIGNAGE WITH ACRYLIC LETTERING TO OUTER FACE AND BUILT-IN ILLUMINATION TO INSIDE
15. (H42/150) GRC SOFFIT PANELS WITH CONCEALED FIXINGS ON S/S SUB FRAME. FINISH TO MATCH ACID ETCHED, REINFORCED CONCRETE
CLADDING BY TECHRETE OR EQUIV. COLOUR TBC. EPDM FLASHING & SEALS TO ADJOINING WORKS. TARGET U-VALUE 0.23W/m2K.
16. (L10/680) PROPRIETARY GLASS-MOUNTED SIGNAGE WITH ACRYLIC LETTERING TO OUTER FACE AND BUILT-IN ILLUMINATION TO INSIDE
FACE. BY WIDD SIGNS OR EQUIVALENT
17. (H92/120A) IAC NOISHIELD ACOUSTIC BARRIER. FS/A - 22.0, 127MM THICK. PPC ALUMINIUM FINISH. THE SCREEN SHOULD HAVE A MINIMUM
1.
2.
DO NOT SCALE FROM THIS DRAWING
DETAILS OF ANY EXISTING STRUCTURES HAVE BEEN
REPRODUCED IN GOOD FAITH FROM ARCHIVE DRAWINGS AND
SURVEY INFORMATION PROVIDED BY OTHERS
3.
ALL DRAWINGS SHOULD BE READ IN CONJUNCTION WITH THE
RELEVANT ARCHITECTURAL, STRUCTURAL, MECHANICAL &
ELECTRICAL SPECIFICATION
4.
ALL DIMENSIONS SHOWN ON THIS DRAWING ARE TO BE VERIFIED
ON SITE BY THE CONTRACTOR PRIOR TO COMMENCEMENT OF
MANUFACTURE
5.
FOR ALL EXTERNAL BUILDING WORKS, GRADIENTS, DRAINAGE &
SURFACING, REFER TO STRUCTURAL ENGINEER'S DRAWINGS
6.
FOR DETAILS OF ALL PRIMARY, SECONDARY AND SUB
STRUCTURES, REFER TO THE CONSULTANT STRUCTURAL
ENGINEER
7.
FOR DETAILS OF ALL MECHANICAL, ELECTRICAL & ABOVE
GROUND DRAINAGE, REFER TO THE CONSULTANT ENGINEERS
8.
PROPOSALS REMAIN SUBJECT TO PLANNING APPROVAL
9.
PROPOSALS REMAIN SUBJECT TO BUILDING CONTROL APPROVAL
10.
THIS DRAWING IS INTENDED TO OUTLINE DESIGN INTENT ONLY.
THE DETAIL DESIGN OF ALL COMPONENTS IS TO BE AGREED WITH
THE AGREED SUPPLIER IN ACCORDANCE WITH THE PROFILES
SHOWN ON THE DRAWING AND THE PERFORMANCE CRITERIA
OUTLINED IN THE SPECIFICATION
11.
THE DETAIL DESIGN OF ALL ELEMENTS THAT FORM PART OF THE
CLADDING SYSTEM IS TO BE FINALISED BY THE SPECIALIST
SUB-CONTRACTOR IN ACCORDANCE WITH THE REQUIREMENTS
OF THE ARCHITECTURAL DRAWINGS AND SPECIFICATIONS
12.
THE CONTRACTOR SHOULD DEVELOP AND CONFIRM PROPOSALS
FOR CLEANING, MAINTENANCE AND REPLACEMENT OF ALL
COMPONENTS IN ORDER TO SAFEGUARD THE SYSTEM
WARRANTY.
13.
PROPOSALS REMAIN SUBJECT TO CO-ORDINATION WITH FACADE
LIGHTING, MAINTENANCE ACCESS AND BIRD DETERRENT
SYSTEMS.
14.
DETAILS OF ALL SUPPORT SYSTEMS, BRACKETS AND FIXINGS TO
THE PRIMARY STRUCTURE ARE TO BE DEVELOPED IN
ACCORDANCE WITH THE STRUCTURAL ENGINEER'S
REQUIREMENTS.
15.
THE CONTRACTOR IS TO ENSURE THAT ALL CLADDING SYSTEM
INTERFACE DETAILS ARE CO-ORDINATED SO THAT THE
RESULTING ENVELOPE CAN BE TESTED FOR COMPLIANCE WITH
CWCT REQUIREMENTS FOR AIR TIGHTNESS AND INTEGRITY.
16.
ALL PLASTERBOARD JOINTS TO BE TAPED AND SEALED. ALL
JOINTS BETWEEN COMPONENTS TO BE ROBUSTLY SEALED IN
ACCORDANCE WITH BSRIA RECOMMENDATIONS
17.
NOTE: FINISHED FLOOR LEVELS TO BE CONFIRMED. EXISTING
BUILDING. DRAWINGS TO BE ALIGNED WITH ORDNANCE SURVEY
BENCHMARK AND TOPOGRAPHICAL SURVEY LEVELS
* NB: FFL EXCLUDES NOM. 10MM ZONE FOR DECORATIVE FLOOR
FINISHES
18. (L20/280A) STEEL FACED SOLID CORE TIMBER ESCAPE DOOR BY ARMOURPOST OR EQUIVALENT. POLYESTER POWDER COAT FINISH:
STANDARD RAL COLOUR TBC.
19. (L20/610A) SECURITY SHUTTERS TO MAIN ENTRANCES BY: RING-GUARD UK OR EQUIVALENT: ALUMINIUM GRILLE, BRICK BOND PATTERN.
ALUMINIUM FRAMING FITTED INTO REVEAL. SHUTTER FINISH: POLYESTER POWDER COATED, COLOUR RAL 9006. FRAME FINISH: POLYESTER
POWDER COATED. COLOUR RAL 9006.
20. (L20/615A) INSULATED SECTIONAL UP AND OVER DOOR TO LOADING BAY BY KABA DOORS OR EQUIV STANDARD LIFT TRACK SYSTEM. DOOR
PANEL GALVANISED STEEL INNER AND OUTER FACE INFILLED WITH HIGH DENSITY POLYURETHANE FOAM. STANDARD ENAMEL FINISH: RAL
9006. GALV STEEL FRAME/ GUIDES: ELECTRICAL OPERATION WITH EMERGENCY HAND CHAIN DOOR ASSEMBLY TO MEET MINIMUM TARGET
U-VALUE OF 1.5W/m2K. DRAFT SEALS TO ALL EDGES AN OPENINGS.
21. (H42/---) PRECAST CONCRETE VERTICAL BRANDING INTEGRATED WITHIN PRECAST CONCRETE CLADDING. BY TECHRETE OR EQUIVALENT
22. NOT USED
23. (L10/450) INSULATED LOUVRE TO SMOKE EXTRACT SYSTEM AS COLT EN SEEFIRE WITH AUTOMATIC ACTUATOR AND FACTORY FITTED
SECURITY GUARD. PPC FINISH COLOUR TBC
24.) SUB-STATION - IN ACCORDANCE WITH UK POWER NETWORKS REQUIRMENTS. REFER TO UTILITY SUPPLIERS DETAIL RECOMMENDATIONS.
25. (L10/470) STAINLESS STEEL ACCESS LADDER WITH HOOPED CAGE TO ACCESS ROOF PLANT AREAS (REFER TO MECHANICAL CONTRACTORS
DRAWINGS FOR SCOPE OF BWICS)
26. STAINLESS STEEL DRY RISER INLET CABINET
27. STREET LIGHTING TO EDEN STREET TO BE MAINTAINED. REPLACE EXISTING FITTING TO HIGHWAYS AUTHORITY SPECIFICATION. DETAILS
AND LOCATIONS TO BE AGREED WITH RBK
28. (L10/480) ARMCO BOLT DOWN BARRIER
29. (L10/490) SHEFFIELD STAINLESS STEEL BOLLARD
30. (H42/130) WET CAST CONCRETE / CAST STONE CLADDING SYSTEM BY TECHRETE OR EQUIVALENT WITH RECESSED SHADOW GAPS ACID
VAPOUR BARRIER TO THE BACK OF THE INSULATION. TARGET U-VALUE 0.23W/m2K.
31. (H11/130) ALUMINIUM FRAMED NON-VISION DOUBLE GLAZED WINDOW SYSTEM SUCH AS SCHUCO FW50+ OR EQUIVALENT. FRAMEWORK &
FLASHINGS PPC FINISH STANDARD RAL COLOUR (RAL 7043). OPAQUE COLOURED GLAZING FILM WITH CUSTOMISED GRAPHIC (COLOUR TBC)
8mm TOUGHENED OUTER 16mm ARGON CAVITY, 12.8mm TOUGHENED ARMOURCLAD LINING. TO ACHIEVE A MINIMUM U-VALUE OF 1.5W/M2K AS
REGULATION L2A APPENDIX A. EXTENT OF VISION / NON-VISION WINDOWS SUBJECT TO CONFIRMATION OF RETAILING LAYOUTS BY PSL
32. EXISTING BRICKWORK RETAINED
33. (M21/210A) OUTSULATION BY DRYVIT OR EQUIVALENT. RENDER ON REINFORCED MESH EMBEDDED BASE COAT ON INSULATION BOARD
(DEPTH TBC) ON 5MM DRYVIT GENESIS ADHESIVE DABS ON WATER RESISTIVE BARRIER COAT ON EXISTING EXTERNAL BRICKWORK. TARGET
U-VALUE 0.23W/m2K. FINISH: SANDPEBBLE FINE. COLOUR TBC.
34. (M21/210B) OUTSULATION BY DRYVIT OR EQUIVALENT. RENDER ON REINFORCED MESH EMBEDDED BASE COAT ON 140MM EXPANDED
POLYSTYRENE INSULATION BOARD ON DRYVIT ADHESIVE ON RCM Y WALL CEMENTITIOUS BOARD SUBSTRATE ON SFS FRAME. TARGET
U-VALUE 0.23W/m2K . FINISH: SANDPEBBLE FINE. COLOUR TBC.
35. (M21/210C) OUTSULATION BY DRYVIT OR EQUIVALENT. RENDER ON REINFORCED MESH EMBEDDED BASE COAT ON INSULATION BOARD &
DRYVIT ADHESIVE WATER RESISTIVE BARRIER COAT ON 100MM BLOCKWORK. TARGET U-VALUE 0.23W/m2K. FINISH: LIMESTONE. COLOUR TBC.
36. FACING BRICKWORK TO MATCH EXISTING (USE RETAINED BRICK WHERE POSSIBLE) ON 70MM KOOLTHERM K12 INSULATION WITH 50MM
AIRSPACE ON 200MM METAL STUD ON VAPOUR BARRIER ON 2X12.5 MM WALLBOARD. TARGET U-VALUE 0.23W/m2K.
37. (L30/580A) FREESTANDING GALVANISED STEEL BARRIER TO ROOF: INCLINED VERSIRAIL BY LATCHWAY OR EQUIVALENT TO EN13374, EN ISO
14122-3 SECTION 8.2, EUROPEAN DIRECTIVE 2001/45/CE, BS6399; PART 2 1997, WORKING AT HEIGHT REGS 2005
38. (M21/210D) OUTSULATION BY DRYVIT OR EQUIVALENT. RENDER ON REINFORCED MESH EMBEDDED BASE COAT ON INSULATION BOARD
(DEPTH TBC) ON 5MM DRYVIT GENESIS ADHESIVE DABS ON WATER RESISTIVE BARRIER COAT ON BRICK / BLOCK ON 70MM KOOLTHERM K12
INSULATION WITH 50MM AIRSPACE ON 200MM METAL STUD ON 2X12.5 MM WALLBOARD WITH VAPOUR BARRIER. TARGET U-VALUE 0.23W/m2K
FINISH: LIMESTONE COLOUR TBC
39. GALVANISED STEEL ACCESS GATE WITH LATCH LOCK - EXISTING GATE TO BE SURVEYED, MADE GOOD AND RETAINED IF SUITABLE
NUMBERS/UNITS INTEGRATED WITHIN WET CAST CONCRETE / CAST STONE CLADDING SYSTEM
29.528
29.010
13
37
26.127
25.575 FOURTH FLOOR
1:100
0
1
2
3
4
5
6
7
8
9
SPRINKLER ZONE
KEY:
34
SITE BOUNDARY
21.600 THIRD FLOOR
RETAIL AREAS
34
STOCK AREAS
CASH & WRAP
RETURNS
STAFF AREAS
RETAIL
ANCILLARY AREAS
PLANNING
DO-NOT-USE-FOR-CONSTRUCTION
CASH & WRAP
FEMALE FITTING
FEMALE FITTING
RETAIL
50mm Dp RECESS TO
BE FORMED LOCAL TO
GLAZING BASE PLATE
130mm THK COMPOSITE
FLOOR SLAB. SEE PLAN
130
12.525 FIRST FLOOR
NEW SCREEN IN
ACCORDANCE WITH
ARCHITECT'S DETAILS
SSL
12.525m
3.3 04.04.16
254 x 146 UB
610 x 305 UB
3.2 03.12.15
GLAZING HEAD RESTRAINT
IN ACCORDANCE WITH
SPECIALISTS DETAILS
20
SECTION 14 - 14
3.1 09.11.12
3.0 17.10.12
(SCALE 1=20)
RETAIL
ROOF PLANT AMENDED WITH NEW
AHUS TO EU DIRECTIVE
ROOF PLANT AMENDED, SECOND FLOOR
RECESS ADDED, SUB-STATION INTAKE
ADDED
RETAIL CEILING HEIGHTS REVISED
ISSUED FOR INFORMATION ONLY
LM
NDP
LM
NDP
EMc
EMc
NDP
NDP
9.285
CORR.
CCTV
EDEN STREET
7.975 GROUND FLOOR
REFER TO STRUCTURAL
ENGINEER'S DRAWINGS FOR
EXISTING SUB STRUCTURE
INFORMATION
7.975 GROUND FLOOR
MALE FITTING ROOM
REFER TO STRUCTURAL
ENGINEER'S DRAWINGS FOR
EXISTING SUB STRUCTURE
INFORMATION
3.425 LOWER GROUND FLOOR
PRIMARK
EDEN STREET
KINGSTON ON THAMES
SECTION C-C
3DReid
36 North Castle Street
Edinburgh EH2 3BN
T 0131 225 4040
F 0131 225 4747
W www.3DReid.com
090486 1:100@A1
20.02.11
Dra 3DR 581 AR 9963
EM
NdP
3.3
10
Download