0 Standards and principles 5 1 Enclosures, terminal boxes, junction boxes 15 2 Assembled housings 47 3 Lighting 61 4 Signalling 95 5 Switches, control units, sockets and plugs 105 6 Heating 133 7 Man - machine interface 143 8 Cable glands and accessories 155 9 Miscellaneous 195 EDITION 2011-10 www.ysebaert.be ● info@ysebaert.be ● T +32(0)3 328 06 60 ● F +32(0)3 328 06 80 1 0 Explosion safety standards and principles 1 EN / IEC standards ........................................................................................ 5 2 Protection methods ........................................................................................ 6 3 Classification into groups and temperature classes ....................................... 8 4 Classification in zones and choice of electrical equipment (= categories) ..... 9 5 Equipment Protection Level ......................................................................... 10 6 Certification .................................................................................................. 12 www.ysebaert.be ● info@ysebaert.be ● T +32(0)3 328 06 60 ● F +32(0)3 328 06 80 3 0 Explosion safety standards and principles 1 EN / IEC standards 0 Explosion safety standards and principles Introduction During the production, handling, storage and transport of flammable products, gases are inevitably released. In combination with air these gases form an explosive mixture. A spark, or even a hot surface, can cause an explosion, jeopardising man and material. Therefore, explosion hazardous environments are a very specific area, for which international legislation has issued specific construction and installation regulations. In many industries powder and dust is raised during production. Most of the substances in powderform contain a risk for fire or explosion, no matter if it concerns raw materials or waste products (for example with the production of plastics, greases or farmaceuticals). 80% of all dusts occuring in industry is flammable; for a dust layer of 1 mm thickness in a sealed room this can already result in a dust explosion due to air raising clouds of dust. All this together with the rather limited knowledge of the dangers, in contrast with gasexplosionsafety, emphasize the importance of this theme of dustexplosionsafety On March 1st 1996 the directive 94/9/EC was issued, better known as ATEX95. Standards A.o. the following standards are applicable to explosionsafe electrical equipment Protection method EN / IEC General requirements (Gas) 60079-0 Flameproof enclosures “d” 60079-1 Pressurized apparatus “p” 60079-2 Powder filling “q” 60079-5 Oil immersion “o” 60079-6 Increased safety “e” 60079-7 Intrinsic safety “i” 60079-11 Protection “n” 60079-15 Encapsulation “m” 60079-18 Intrinsically safe electrical systems 60079-25 Classification of hazardous areas (Gas) 60079-10 Electrical installations in hazardous areas (Gas) 60079-14 Inspection and maintenance of electrical installations in hazardous areas (Gas) 60079-17 General requirements (Dust) 61241-0 Protection “tD” 60079-31 Protection “pD” 61241-4 Protection “iD” 60079-11 Protection “mD” 60079-18 Reparation and revision 61241-19 Classification of hazardous areas (Dust) 61241-10 Electrical installations in hazardous areas (Dust) 61241-14 Inspection and maintenance of electrical installations in hazardous areas (Dust) 61241-17 www.ysebaert.be ● info@ysebaert.be ● T +32(0)3 328 06 60 ● F +32(0)3 328 06 80 5 0 Explosion safety standards and principles 2 Protection methods Protection methods for gas environments: Flameproof enclosure “d” With this protection method any sparking parts, that may ignite an explosive atmosphere, are placed inside a housing that is able to withstand the pressure of an internal explosion and impede the propagation of the explosion to the surrounding atmosphere. This requires a precise construction of the material, with flanges and threads having a welldetermined gap width and length. Increased safety “e” This protection method refers to equipment that does not ordinarily produce sparks and for which special precautions must be taken during construction. Unacceptably high temperatures must also be avoided, during both regular operation and certain irregular situations. Pressurized apparatus “p” The ingress of an explosive atmosphere in a housing containing electrical equipment, is avoided by maintaining a protective gas (air or an inert gas) at a slight overpressure to the surrounding atmosphere. The overpressure may or may not be maintained by continuous flow. P Intrinsic safety “i” R U L C This protection method applies to a complete circuit. A circuit is intrinsically safe when there are no sparks or thermal effects that may cause an explosive atmosphere to ignite under particular circumstances. Oil immersion “o” Electrical equipment or parts of it are immersed in oil, thus avoiding ignition of the explosive atmosphere above the oil surface or outside the housing. This protection method is rarely applied now. Powder filling “q” This protection is achieved by filling a housing with a powdered material. An electric arc or spark, originating in the housing, is thus prevented from igniting the explosive atmosphere. Encapsulation “m” With this protection method all parts that may ignite an explosive atmosphere, are encapsulated in a resin that is sufficiently resistant to ambient influences. The atmosphere must neither be ignited by sparks, nor by heating inside the encapsulation. Protection “n” These mode of protection can be achieved in 5 different ways : - non sparking apparatus (A) - housing “restricted breathing” (R) - apparatus with limited energy (L) - housing with simplified overpressure (P or Z) - sparking apparatus where the contacts are properly protected, differently as in “restricted breathing”, apparatus with limited energy and simplified overpressure (C) 6 For certificates, spare parts, light intensity diagrams, etc., please consult our website: www.ysebaert.be 0 Explosion safety standards and principles 2 Protection methods Protection methods for dust environments: Protection by enclosure “tD” This method is based on the maximum surface temperature of the enclosure and the limited ingress of explosive dust by using dustproof and dust-preventing enclosures. Intrinsic safety “iD” R The dust protection method “iD” is deduced from the gas protection method “i”. Additional prescriptions are to be followed. L C U Pressurized apparatus “pD” P The ingress of an explosion-hazardous dust atmosphere in a housing containing electrical equipment, is avoided by maintaining a protective gas (air or an inert gas) at a slight overpressure to the surrounding atmosphere. Prepurging is in this case forbidden since the deposited dust will cause an explosive atmosphere when it is raised in a dust cloud. Encapsulation “mD” The dust protection method “mD” is deduced from the gas protection method “m”. Additional prescriptions are to be followed. www.ysebaert.be ● info@ysebaert.be ● T +32(0)3 328 06 60 ● F +32(0)3 328 06 80 7 0 Explosion safety standards and principles 3 Classification into groups and temperature classes Not all explosion-proof equipment can be constructed in accordance with the maximum demands, i.e. applied in all explosive atmospheres. At first instance the European standards distinguish two equipment groups: Group I: electrical equipment for mines that are susceptible to firedamp Group II: electrical equipment for all other potentially explosion-hazardous spaces Equipment of group II is subdivided into explosion groups and temperature classes. Grouping of electrical apparatus Depending on the ignition and sparking characteristics of an explosive mixture, gases and vapours are divided into explosion groups. Categorisation criteria are the gap dimensions, the minimum ignition energy respectively, that have been determined empirically for the various gases. Electrical equipment is marked to indicate for which group (A , B or C) it is designed. Group IIC has the most severe characteristics and can also be used for gases in subdivisions A and B. Location Group Examples of gases Mines susceptible to firedamp I Methane IIA Propane, Octane, Acetone, Ammonia IIB Ethylene, Carbon monoxide IIC Hydrogen, Carbon disulphide Other locations Temperature classes The ignition temperature depends on the nature and characteristics of the gases present. Explosionproof equipment must not have an external temperature that could become a source of self-ignition for the surrounding atmosphere. The electrical equipment of group II is therefore subdivided into the following temperature classes, depending on the maximum surface temperature: Temperature class Maximum surface temperature T1 450°C T2 300°C T3 200°C T4 135°C T5 100°C T6 85°C The maximum surface temperature of an electrical device must be constantly lower than the ignition temperature for the gas or vapour mixture in which it is used. Classification of certain gases The table below provides the explosion group and temperature class for a number of gases and vapours. Name of the substance Ignition temperature Temperature class Acetylene 305 T2 Explosion group IIC Ammonia 630 T1 IIA Butane 365 T2 IIA Ethane 515 T1 IIA Ethanol 425 T2 IIA Ethylene 425 T2 IIB Carbon monoxide 605 T1 IIB Methane 595 T1 I Octane 210 T3 IIA Propane 470 T1 IIA Hydrogen 560 T1 IIC Carbon disulphide 102 T5 IIC The above-mentioned classification is only for information purposes. Variations are always possible, so that verification through an official body is recommended. 8 For certificates, spare parts, light intensity diagrams, etc., please consult our website: www.ysebaert.be 0 Explosion safety standards and principles 4 Classification in zones and choice of electrical equipment (= categories) Classification in zones (for gasexplosions) Any area or environment where a gas explosion hazard may occur, is categorised in zones (0, 1 or 2), depending on the risk related with the possible presence of an explosive mixture in that area. Zone Description Example 0 Includes areas where an explosion hazardous gasatmosphere is continuously present - inside of a vessel - inside of reactor chambers 1 Includes areas where an explosion hazardous gasatmosphere is occasionally present - near filling holes - near zone 0 - near pumps and valves 2 Includes areas where an explosion hazardous gasatmosphere is rarely and for a short time present - near zone 0 or 1 - near flange connections with flat seals It is obvious that the zones should be kept as limited as possible and the use of electrical equipment shall be avoided where possible. There is a similar division for dustexplosions (zone 20, 21 and 22). Choice of electrical equipment The apparatus is fitted with an additional marking (= category) that informs the user in which zone the apparatus can be installed. Apparatus destined for mines who can contain minegas: Category according to 94/9/EC Level of protection Number of incidents M1 Remains functional with an explosive atmosphere Very high 2 M2 De-energized in the event of an explosive atmosphere High 1 Apparatus destined for explosion-hazardous areas other than mines: Zone according to 1999/92/EC 0 Nature of atmosphere Explosive atmosphere G Gas Category of equipment according to 94/9/EC D Dust 1 G Gas D Dust 2 G Gas D Dust 2 High 1 Normal 0 2G 2D 3G Rarely 22 Very high 1D Occasionally 21 Number of incidents 1G Continuous 20 Level of protection 3D www.ysebaert.be ● info@ysebaert.be ● T +32(0)3 328 06 60 ● F +32(0)3 328 06 80 9 0 Explosion safety standards and principles 5 Equipment Protection Level 5 Equipment Protection Level Equipment protection level Historically it was acceptable to install equipment into specific zones based on the type of protection. In some cases it has been shown that the type of protection may be divided into different levels of protection that can be correlated against each zone. A better risk assessment would consider all factors. When using a risk assessment approach instead of the inflexible approach of the past linking equipment to zones, the inherent ignition risk of the equipment is clearly indicated, no matter what type of protection is used. Group I: mines EPL Ma: Apparatus for installation in a mine, with a very high safety protection level, that remains functional in an explosion-hazardous environment, even with an exceptional fault EPL Mb: Apparatus for installation in a mine, with a high safety protection level, that will be de-energized in the event of an explosive atmosphere. Group II: gas EPL Ga: Apparatus for installation in an explosion-hazardous gasatmosphere, with a very high protection level, that even in the event of an exeptional fault of the apparatus, still guarantee the safety level. EPL Gb: Apparatus for installation in an explosion-hazardous gasatmosphere, with a high protection level, that in the event of occasional faults of the apparatus, still guarantee the safety level. EPL Gc: Apparatus for installation in an explosion-hazardous gasatmosphere, with a normal protection level, that guarantee this safety level in the event of normal working. Group III: dust EPL Da: Apparatus for installation in an explosion-hazardous dustatmosphere, with a very high protection level, that even in the event of an exeptional fault of the apparatus, still guarantee the safety level. EPL Db: Apparatus for installation in an explosion-hazardous dustatmosphere, with a high protection level, that in the event of occasional faults of the apparatus, still guarantee the safety level. EPL Dc: Apparatus for installation in an explosion-hazardous dustatmosphere, with a normal protection level, that guarantee this safety level in the event of normal working. Relation between EPL and zones Zone 10 Equipment protection levels (EPLs) 0 Ga 1 Ga or Gb 2 Ga, Gb, or Gc 20 Da 21 Da or Db 22 Da, Db or Dc For certificates, spare parts, light intensity diagrams, etc., please consult our website: www.ysebaert.be 0 Explosion safety standards and principles 5 Equipment Protection Level Assignment of EPLs to the IEC/EN protection methods EPL Type of protection Code ‘Ga’ Intrinsically safe ‘ia’ IEC 60079-11 Encapsulation ‘ma’ IEC 60079-18 ‘Gb’ Two independent types of protection each meeting EPL ‘Gb’ IEC 60079-26 Protection of equipment and transmission systems using optical radiation IEC 60079-28 Flameproof enclosures ‘d’ IEC 60079-1 Increased safety ‘e’ IEC 60079-7 Intrinsically safe ‘ib’ IEC 60079-11 Encapsulation ‘m’ or ‘mb’ IEC 60079-18 Oil immersion ‘o’ IEC 60079-6 Pressurized enclosures ‘p’, ‘px’ or ‘py’ IEC 60079-2 Powder filling ‘q’ IEC 60079-5 Fieldbus intrinsically safe concept (FISCO) IEC 60079-27 Protection of equipment and transmission systems using optical radiation ‘Gc’ IEC 60079-28 Intrinsically safe ‘ic’ IEC 60079-11 Encapsulation ‘mc’ IEC 60079-18 Non-sparking ‘n’ or ‘nA’ IEC 60079-15 Restricted breathing ‘nR’ IEC 60079-15 Energy limitation ‘nL’ IEC 60079-15 Sparking equipment ‘nC’ IEC 60079-15 Pressurized enclosures ‘pz’ IEC 60079-2 Fieldbus non-incendive concept (FNICO) IEC 60079-27 Protection of equipment and transmission systems using optical radiation ‘Da’ ‘Db’ ‘Dc’ According to IEC 60079-28 Intrinsically safe ‘iD’ IEC 60079-11 Encapsulation ‘mD’ IEC 60079-18 Protection by enclosure ‘tD’ IEC 60079-31 Intrinsically safe ‘iD’ IEC 60079-11 Encapsulation ‘mD’ IEC 60079-18 Protection by enclosure ‘tD’ IEC 60079-31 Pressurized enclosures ‘pD’ IEC 61241-4 Intrinsically safe ‘iD’ IEC 60079-11 Encapsulation ‘mD’ IEC 60079-18 Protection by enclosure ‘tD’ IEC 60079-31 Pressurized enclosures ‘pD’ IEC 61241-4 www.ysebaert.be ● info@ysebaert.be ● T +32(0)3 328 06 60 ● F +32(0)3 328 06 80 11 0 Explosion safety standards and principles 6 Certification In Europe some test institutes are authorised to carry out tests on explosionproof equipment and to issue the corresponding certificates. Procedures for certification The directive 94/9/EC extensively describes the assessment procedures for compliance. A short overview is given in the following tabel. Category 1 or M1 + autonomous protective systems Category 2 or M2 (electrical equipment and ignition sources) Category 2 or M2 (other apparatus) Category 3 or or or or Internal control Unit of production + verification by communicate N.B. a technical documentation to a N.B. Unit Internal control verification by of production N.B. E.C. Typeexamination by N.B. Unit verification by N.B. or Unit verification by N.B. or Product Production QA verification by by N.B. N.B. 12 E.C. Typeexamination by N.B. Product QA by Conformity to N.B. type For certificates, spare parts, light intensity diagrams, etc., please consult our website: www.ysebaert.be 1 Enclosures, terminal boxes, junction boxes 1 Enclosures Exd IIB+H2 ................................................................................ 15 1 EJB series - aluminium ..................................................................... 15 2 Enclosures Exd IIC....................................................................................... 18 1 GUB series - aluminium .................................................................... 18 2 EMH series - with window ................................................................. 19 3 Enclosures EExde IIC .................................................................................. 20 1 DE8-WH series - EExd box............................................................... 20 2 DE1-WH series - EExe box............................................................... 21 4 Terminal boxes polyester ............................................................................. 22 1 CONNECTA-P series ........................................................................ 22 5 Enclosures stainless steel ............................................................................ 30 1 AR/AQ series .................................................................................... 30 2 NXT series ........................................................................................ 31 6 Junction boxes Exe plastic ........................................................................... 33 1 BJE series ......................................................................................... 33 7 Construction site boxes ................................................................................ 34 1 2 3 4 5 8 Solid rubber....................................................................................... 34 Cable reel.......................................................................................... 35 Standard construction site box - type Y11138 ................................... 36 Transformers ..................................................................................... 37 Standard transformer ........................................................................ 38 EX-PRESS pressurized enclosures Exp ...................................................... 39 1 Serie FS850S.................................................................................... 39 2 Serie FS840 ...................................................................................... 43 www.ysebaert.be ● info@ysebaert.be ● T +32(0)3 328 06 60 ● F +32(0)3 328 06 80 13 1 Enclosures, terminal boxes, junction boxes 1 Enclosures Exd IIB+H2 1 EJB series - aluminium The EJB series flameproof enclosures are available in 12 different sizes, allowing a suitable housing to be found for every application. Depending on the customer’s specifications, the boxes can be fitted with terminals, magnetic switches, circuit breakers, electronic components, etc. II 2 G Exd IIB+H2 T6/T5/T4 II 2(1) G Exd [ia] IIB+H2 T6 II 2(2) G Exd [ib] IIB+H2 T6 II 2 D Ex tD A21 IP65 T85°C/T100°C/T135°C Specifications Material Protection Seal Mounting plate Cover bolts Earthing Ambiant temperature Mounting corrosion- and saltwaterresistant aluminium with polyurethane paint, RAL9002 IP65 special grease on the flanges to guarantee the IP-degree galvanised, 3mm thick stainless steel internal and external stainless steel M6 bolt -20°C - +40°C the rear is fitted with 4 threaded holes Zone 1 Zone 2 Zone 21 Zone 22 INERIS02ATEX0071X On request • • • • • • • control units in cover hinges (stainless steel) galvanised mounting brackets for wall mounting entries with or without glands rectangular or round windows installation of electric/electronic components ambiant temperature -50°C - +55°C Ordering data Code Dimensions (hxwxd) (mm) Mounting plate (mm) Useable depth (mm) Weight EJB-Y-02 298 x 238 x 174 220 x 160 135 10,7 kg EJB-Y-03 412 x 238 x 177 330 x 155 136 13,4 kg EJB-Y-04 418 x 302 x 175 325 x 210 132 17,5 kg EJB-Y-05 480 x 300 x 232 385 x 200 182 20,5 kg EJB-Y-06 483 x 408 x 238 380 x 300 186 33,0 kg EJB-Y-08 634 x 365 x 254 520 x 250 204 36,5 kg EJB-Y-09 535 x 468 x 257 420 x 350 204 40,0 kg EJB-Y-10 750 x 366 x 292 620 x 240 234 48,5 kg EJB-Y-11 596 x 505 x 267 470 x 380 203 53,3 kg EJB-Y-12 805 x 455 x 310 675 x 325 243 73,0 kg EJB-Y-13 832 x 607 x 314 690 x 470 236 106,0 kg EJB-Y-13A 832 x 607 x 400 690 x 470 322 124,0 kg www.ysebaert.be ● info@ysebaert.be ● T +32(0)3 328 06 60 ● F +32(0)3 328 06 80 15 1 Enclosures, terminal boxes, junction boxes 1 Enclosures Exd IIB+H2 1 EJB series - aluminium Dimensional sketches Product code Dimensions A B C D E F G H I L N P R EJB-Y-02 298 238 174 230 168 85 135 205 140 250 10 6x1 20 EJB-Y-03 412 238 177 340 167 85 136 330 150 250 10 8x1,25 20 EJB-Y-04 418 302 175 336 220 75 132 300 190 300 10 8x1,25 20 EJB-Y-05 480 300 232 392 209 125 182 350 185 300 10 8x1,25 20 EJB-Y-06 483 408 238 387 311 130 186 355 280 390 10 8x1,25 20 EJB-Y-08 634 365 254 531 262 140 204 495 225 340 10 8x1,25 20 EJB-Y-09 535 468 257 426 363 145 204 410 340 440 10 10x1,5 20 EJB-Y-10 750 366 292 630 248 180 234 580 205 330 14 10x1,5 20 EJB-Y-11 596 505 267 483 394 140 203 445 360 480 14 10x1,5 20 EJB-Y-12 805 455 310 690 336 185 243 640 285 475 14 12x1,75 20 EJB-Y-13 832 607 314 723 500 125 236 630 405 580 14 12x1,75 20 EJB-Y-13A 832 607 400 723 500 225 322 630 405 580 14 12x1,75 20 Accessories Switches Code AC1 660V : 20A AC23 500V : 16A Schema PSRC220 PSRC420 PSRC-D220 PSRC-C220 Key switches AC11 220V : 4,5A / 380V : 2,6A / 500V : 2,1A In = 10A Contactblocks to be ordered separately. Code Contact block PLF10 020E10 1NO 020E01 1NC Push buttons AC11 220V : 4,5A / 380V : 2,6A / 500V : 2,1A In = 10A Contactblocks to be ordered separately. 16 Code Colour PLA10 black PLA20 red PLA30 green PLC-S red PLC-S-F red Contact block 020E10 1NO 020E01 1NC For certificates, spare parts, light intensity diagrams, etc., please consult our website: www.ysebaert.be 1 Enclosures, terminal boxes, junction boxes 1 Enclosures Exd IIB+H2 1 EJB series - aluminium Signalling lamps Lamp fitting Ba9s max.230V - max.5W Light bulb to be ordered separately. Code Colour PLD20 red PLD10 white PLD30 green PLD40 yellow PLD50 blue Voltage PLD-LED28VAC/DC 24VAC/DC PLD-LED130VAC 130VAC PLD-LED230AC 230VAC www.ysebaert.be ● info@ysebaert.be ● T +32(0)3 328 06 60 ● F +32(0)3 328 06 80 17 1 Enclosures, terminal boxes, junction boxes 2 Enclosures Exd IIC 1 GUB series - aluminium The GUB series flameproof enclosures are available in 7 different sizes. Depending on the customer’s specifications, the boxes can be fitted with terminals, magnetic switches, circuit breakers, electronic components, etc. II 2 G Exd IIC T6/T5/T4 II 2(1) G Exd[ia] IIC T6 II 2(2) G Exd[ib] IIC T6 Specifications Material Protection Mounting plate Earthing Ambiant temperature Mounting II 2 D Ex tD A21 IP65 T85°C/T100°C/T135°C corrosion- and saltwater- resistant aluminium with polyurethane paint, RAL9002 IP65 aluminium, 2 mm thick internal and external stainless steel M6 bolt -20°C - +40°C mounting eyes Zone 1 Zone 2 Zone 21 Zone 22 INERIS02ATEX0072X On request • • • • entries with or without glands installation of electric/electronic components Flat cover for fixing of components (GUB-QL) ambiant temperature -50°C - +55°C Ordering data Code Dimensions (hxwxd) (mm) Mounting plate (mm) Useable depth (mm) Weight GUB-Y-00 133 x 133 x 142 Ø80 92 2,16 kg GUB-Y-01 169 x 169 x 152 Ø120 100 3,62 kg GUB-Y-02 190 x 190 x 164 Ø145 102 4,72 kg GUB-Y-03 210 x 210 x 179 Ø160 120 5,95 kg GUB-Y-04 281 x 232 x 206 Ø180 145 8,90 kg GUB-Y-05 298 x 257 x 222 Ø195 154 11,86 kg GUB-Y-06 329 x 293 x 248 Ø235 192 15,75 kg Dimensional sketches 18 Product code Dimensions A B C D E F G H I L M Q* GUB-Y-00 133 133 142 110 110 60 92 90 110 100 6 80 GUB-Y-01 169 169 152 139 139 65 100 126 150 150 7 120 GUB-Y-02 190 190 164 160 160 65 102 144 170 170 8 145 GUB-Y-03 210 210 179 180 180 75 120 167 190 190 9 160 GUB-Y-04 281 232 206 202 251 97 145 183 260 210 9 180 GUB-Y-05 298 257 222 227 268 105 154 206 275 235 9 195 GUB-Y-06 329 293 248 259 295 142 192 242 305 270 10 235 For certificates, spare parts, light intensity diagrams, etc., please consult our website: www.ysebaert.be 1 Enclosures, terminal boxes, junction boxes 2 Enclosures Exd IIC 2 EMH series - with window The EMH series windows are suited for the installation of digital and analogue instruments with external readout (meters, displays). II 2 G Exd IIC T6/T5/T4 II 2(1) G Exd[ia] IIC T6 Specifications Material Protection Mounting plate Earthing Ambiant temperature Mounting corrosion- and saltwater- resistant aluminium with polyurethane paint, RAL9002 (EMH90 = RAL6003) IP65 aluminium, 2 mm thick (except EMH90) internal and external stainless steel M6 bolt -20°C - +40°C mounting eyes II 2(2) G Exd[ib] IIC T6 II 2 D Ex tD A21 IP65 T85°C/T100°C/T135°C Zone 1 Zone 2 Zone 21 Zone 22 INERIS02ATEX0072X INERIS03ATEX0009 On request • • • • entries with or without glands installation of electric/electronic components installation of instruments ambiant temperature -50°C - +55°C Ordering data Code Dimensions (hxwxd) (mm) EMH90-V 84 x 175 x 135 EMH-Y-160 210 x 210 x 158 EMH-Y-175 Mounting plate (mm) Window (mm) Weight Ø80 1,47 kg Ø160 Ø160 5,90 kg 281 x 232 x 184 Ø175 Ø175 8,90 kg EMH-Y-200 298 x 257 x 198 Ø200 Ø200 11,86 kg EMH-Y-230 329 x 293 x 236 Ø230 Ø230 15,75 kg Dimensional sketches EMH-Y EMH90-V Product code Dimensions A B C D E F Q EMH90-V 84 175 135 66 134 7 80 EMH-Y-160 210 210 158 190 190 8 160 EMH-Y-175 281 232 184 210 260 8 175 EMH-Y-200 298 257 198 235 275 8 200 EMH-Y-230 329 293 236 270 305 10 230 www.ysebaert.be ● info@ysebaert.be ● T +32(0)3 328 06 60 ● F +32(0)3 328 06 80 19 1 Enclosures, terminal boxes, junction boxes 3 Enclosures EExde IIC 1 DE8-WH series - EExd box The flameproof enclosures of the DE8-WH (EExd) series are particularly suited for the installation of controls and distributions. With the addition of an EExe box, controls (push buttons, lamps, etc) and terminals can be added, guaranteeing a user-friendliness. The EExd and EExe boxes are connected by means of flameproof bushings (number of conductors and section need to be specified). Zone 1 Specifications Zone 2 Material Protection Mounting plate Earthing Ambiant temperature Mounting II 2 G EExd IIC T6/T4 II 2 G EExde IIC T6/T4 II 2 D T85°C - T135°C IP65 steel with aluminium cover and finish IP65 twofold, galvanised steel with M10 threaded rod -20°C - +40°C with 4 mounting feet Zone 21 Zone 22 INERIS03ATEX0121X On request • • • • • entries with or without glands Ø 60 window, centred on cover installation of electric/electronic components built-on EExe box ambiant temperature -20°C - +60°C Ordering data Code Dimensions (hxwxd) (mm) Weight DE8-WH32 330 x 330 x 300 65 kg DE8-WH43 520 x 520 x 300 125 kg DE8-WH64 670 x 670 x 300 200 kg DE8-WH107 1040 x 670 x 360 200 kg Dimensional sketches 20 Product code Dimensions A B C D E F G H I J K L DE8-WH32 330 330 380 210 420 425 300 264 306 306 250 14 DE8-WH43 520 520 570 400 610 425 300 264 496 496 400 14 DE8-WH64 670 670 720 552 760 425 300 264 646 646 550 14 DE8-WH107 670 1040 720 800 360 317 1016 646 550 14 For certificates, spare parts, light intensity diagrams, etc., please consult our website: www.ysebaert.be 1 Enclosures, terminal boxes, junction boxes 3 Enclosures EExde IIC 2 DE1-WH series - EExe box The flameproof enclosures of the DE8-WH (EExd) series are particularly suited for the installation of controls and distributions. With the addition of an EExe box, controls (push buttons, lamps, etc) and terminals can be added, guaranteeing a user-friendliness. The EExd and EExe boxes are connected by means of flameproof bushings (number of conductors and section need to be specified). II 2 G EExe II T6/T4 II 2 G EExed IIC T6/T4 II 2 G EExem II T6/T4 II 2 G EExemd IIC T6/T4 II 2 D T85°C - T135°C IP65 Specifications Material Protection Mounting plate Earthing Ambiant temperature Mounting sheet metal with finish IP65 / IP66 optional earthing bolt -20°C - +50°C fixed connection with EExd box or optional mounting feet Zone 1 Zone 2 Zone 21 Zone 22 INERIS03ATEX0006 On request • • • installation of terminals, control units ambiant temperature -20°C - +60°C mounting plate Ordering data Code Dimensions (hxwxd) (mm) Weight DE1-WH330 250 x 330 x 230 8 kg DE1-WH520 330 x 520 x 230 13 kg DE1-WH670 520 x 670 x 230 22 kg Dimensional sketches Product code Dimensions A B C DE1-WH330 330 250 230 DE1-WH520 520 330 230 DE1-WH670 670 520 230 www.ysebaert.be ● info@ysebaert.be ● T +32(0)3 328 06 60 ● F +32(0)3 328 06 80 21 1 Enclosures, terminal boxes, junction boxes 4 Terminal boxes polyester 1 CONNECTA-P series The polyester terminal boxes of the CONNECTA-P series are available in 23 different sizes. They are very robust and particularly suited for use in aggressive and heavy-duty conditions. With their practical sizes and their flexible certification they can be fitted with terminals and glands of various manufacturers. These terminal boxes are readily available according to your specifications. The boxes are available as assembled terminal boxes or in an empty version, with component certificate. II 2 G Exe II T6 II 1 G Exia IIC T6 II 2(1) G Exe[ia] IIC T6 II 2 D Ex tD A21 IP66 T85°C Zone 0 Zone 1 Zone 2 Zone 20 Zone 21 Zone 22 Specifications Protection Cover bolts Seal Color Material Surfaceresistance Impact Ambiant temperature (for the empty enclosure) Toxic behaviour Waterabsorption Weatherresistance IP66, EN 60529 stainless steel - loss-free silicone RAL 9011 black glass-fibre reinforced polyester, graphitised < 10 GΩ, IEC 60079-0 7Nm (J), IEC 60079-0 -40°C - +100°C halogen-free max.0,7%, ASTM D570 UV-resistant On request • • • • • • terminals earthing strip entries (metric) mounting plate in galvanised steel mounting feet hinges Ordering data 22 Code Dimensions (hxwxd) (mm) Weight Mounting dimensions (mm) Mounting CP0808-U 75 x 80 x 55 0,23 kg 45 x 68 4 x M4 CP0808D-U 75 x 80 x 75 0,3 kg 45 x 68 4 x M4 CP0811-U 75 x 110 x 55 0,295 kg 45 x 98 4 x M4 CP0811D-U 75 x 110 x 75 0,36 kg 45 x 98 4 x M4 CP0816-U 75 x 160 x 55 0,405 kg 45 x 148 4 x M4 CP0816D-U 75 x 160 x 75 0,46 kg 45 x 148 4 x M4 CP0819-U 75 x 190 x 55 0,45 kg 45 x 178 4 x M4 CP0819D-U 75 x 190 x 75 0,53 kg 45 x 178 4 x M4 CP0823-U 75 x 230 x 55 0,575 kg 45 x 218 4 x M4 CP0823D-U 75 x 230 x 75 0,67 kg 45 x 218 4 x M4 CP1032-U 100 x 320 x 80 1,3 kg 45 x 304 4 x M6 CP1212-U 120 x 120 x 90 0,75 kg 82 x 106 4 x M6 CP1222-U 120 x 220 x 90 1,06 kg 82 x 204 4 x M6 CP1616-U 160 x 160 x 90 1,29 kg 110 x 140 4 x M6 CP1626-U 160 x 260 x 90 1,71 kg 110 x 240 4 x M6 CP1636-U 160 x 360 x 90 2,15 kg 110 x 340 4 x M6 CP1656-U 160 x 560 x 90 3,18 kg 110 x 540 4 x M6 CP2526-U 250 x 255 x 120 2,65 kg 200 x 235 4 x M6 CP2526D-U 250 x 255 x 160 3,275 kg 200 x 235 4 x M6 CP2540-U 250 x 400 x 120 3,650 kg 200 x 380 4 x M6 CP2540D-U 250 x 400 x 160 4,8 kg 200 x 380 4 x M6 CP2560-U 250 x 600 x 120 5,235 kg 200 x 580 4 x M6 CP3636-U 360 x 360 x 90 3,67 kg 310 x 340 4 x M6 CP4140-U 405 x 400 x 120 5,58 kg 355 x 380 4 x M6 For certificates, spare parts, light intensity diagrams, etc., please consult our website: www.ysebaert.be 1 Enclosures, terminal boxes, junction boxes 4 Terminal boxes polyester 1 CONNECTA-P series Dimensional sketches Product code Exterior dimensions C/D A/B E CP0808-U 75 80 55 CP0808D-U 75 80 75 CP0811-U 75 110 55 CP0811D-U 75 110 75 CP0816-U 75 160 55 CP0816D-U 75 160 75 CP0819-U 75 190 55 CP0819D-U 75 190 75 CP0823-U 75 230 55 CP0823D-U 75 230 75 CP1032-U 100 320 80 CP1212-U 120 120 90 CP1222-U 120 220 90 CP1616-U 160 160 90 CP1626-U 160 260 90 CP1636-U 160 360 90 CP1656-U 160 560 90 CP2526-U 250 255 120 CP2526D-U 250 255 160 CP2540-U 250 400 120 CP2540D-U 250 400 160 CP2560-U 250 600 120 CP3636-U 360 360 90 CP4140-U 405 400 120 www.ysebaert.be ● info@ysebaert.be ● T +32(0)3 328 06 60 ● F +32(0)3 328 06 80 23 1 Enclosures, terminal boxes, junction boxes 4 Terminal boxes polyester 1 CONNECTA-P series Max. number of connections = f(current, cross-section) Number of terminals = number of connections/2 Dark blue: number of terminals to be defined by manufacturer Light blue: no limit on number of terminals Type CP0808 Current (A) Useful length on DIN rail = 38,5 mm CP0808D Current (A) Useful length on DIN rail = 38,5 mm CP0811 10 16 20 25 35 50 63 80 100 125 160 200 225 250 Current (A) Useful length on DIN rail = 68,5 mm CP0811D 10 16 20 25 35 50 63 80 100 125 160 200 225 250 Current (A) Useful length on DIN rail = 68,5 mm 24 10 16 20 25 35 50 63 80 100 125 160 200 225 250 10 16 20 25 35 50 63 80 100 125 160 200 225 250 Cross-section (mm²) 1,5 27 9 3 2,5 18 10 5 4 - 6 - 10 - 16 - 25 - 35 - 50 - 70 - 95 - 120 - Cross-section (mm²) 1,5 32 11 4 2,5 21 12 6 4 - 6 - 10 - 16 - 25 - 35 - 50 - 70 - 95 - 120 2,5 4 18 11 5 73 21 12 3 6 - 10 - 16 - 25 - 35 - 50 - 70 - 95 - 120 2,5 4 22 13 6 86 25 14 4 6 - 10 - 16 - 25 - 35 - 50 - 70 - 95 - Max. number of glands/plugs Glands Side M A/B C/D 16 5 1 20 3 1 25 2 32 40 50 63 - Cross-section (mm²) 1,5 33 11 4 Max. number of glands/plugs Glands Side M A/B C/D 16 6 2 20 4 2 25 1 1 32 1 40 50 63 - Cross-section (mm²) 1,5 28 9 4 Max. number of glands/plugs Glands Side M A/B C/D 16 3 1 20 2 1 25 1 32 40 50 63 120 Max. number of glands/plugs Glands Side M A/B C/D 16 8 2 20 6 2 25 2 1 32 1 40 50 63 - For certificates, spare parts, light intensity diagrams, etc., please consult our website: www.ysebaert.be 1 Enclosures, terminal boxes, junction boxes 4 Terminal boxes polyester 1 CONNECTA-P series Max. number of connections = f(current, cross-section) Number of terminals = number of connections/2 Dark blue: number of terminals to be defined by manufacturer Light blue: no limit on number of terminals Type CP0816 Useful length on DIN rail = 118,5 mm CP0816D Useful length on DIN rail = 118,5 mm CP0819 Useful length on DIN rail = 148,5 mm CP0819D Useful length on DIN rail = 148,5 mm Current (A) 10 16 20 25 35 50 63 80 100 125 160 200 225 250 Current (A) 10 16 20 25 35 50 63 80 100 125 160 200 225 250 Current (A) 10 16 20 25 35 50 63 80 100 125 160 200 225 250 Current (A) 10 16 20 25 35 50 63 80 100 125 160 200 225 250 Cross-section (mm²) 1,5 28 9 4 2,5 4 19 11 5 74 21 12 3 6 - 10 - 16 - 25 - 35 - 50 - 70 - 95 - 120 - Cross-section (mm²) 1,5 34 11 4 2,5 4 22 13 6 87 25 14 4 6 27 10 - 10 27 8 3 16 22 10 4 25 - 35 - 50 - 70 - 95 - 120 2,5 4 19 11 5 74 21 12 3 6 - 10 - 16 - 25 - 35 - 50 - 70 - 95 - 120 2,5 4 6 22 13 6 87 25 14 4 27 10 10 26 8 3 16 22 10 4 25 36 11 4 35 - 50 - 70 - 95 - Max. number of glands/plugs Glands Side M A/B C/D 16 10 1 20 6 1 25 4 32 40 50 63 - Cross-section (mm²) 1,5 33 11 4 Max. number of glands/plugs Glands Side M A/B C/D 16 14 2 20 10 2 25 3 1 32 2 40 50 63 - Cross-section (mm²) 1,5 28 9 4 Max. number of glands/plugs Glands Side M A/B C/D 16 8 1 20 5 1 25 3 32 40 50 63 120 Max. number of glands/plugs Glands Side M A/B C/D 16 16 2 20 12 2 25 4 1 32 3 40 50 63 - www.ysebaert.be ● info@ysebaert.be ● T +32(0)3 328 06 60 ● F +32(0)3 328 06 80 25 1 Enclosures, terminal boxes, junction boxes 4 Terminal boxes polyester 1 CONNECTA-P series Max. number of connections = f(current, cross-section) Number of terminals = number of connections/2 Dark blue: number of terminals to be defined by manufacturer Light blue: no limit on number of terminals Type CP0823 Current (A) Useful length on DIN rail = 188,5 mm CP0823D Current (A) Useful length on DIN rail = 188,5 mm CP1032 10 16 20 25 35 50 63 80 100 125 160 200 225 250 Current (A) Useful length on DIN rail = 274,5 mm Minimum ordering quantity; please contact us CP1212 10 16 20 25 35 50 63 80 100 125 160 200 225 250 Current (A) Useful length on DIN rail = 67,5 mm 26 10 16 20 25 35 50 63 80 100 125 160 200 225 250 10 16 20 25 35 50 63 80 100 125 160 200 225 250 Cross-section (mm²) 1,5 33 11 4 2,5 4 6 22 13 6 86 25 14 4 27 10 10 26 8 2 16 22 10 3 25 36 11 4 35 - 50 - 70 - 95 - 120 - Cross-section (mm²) 1,5 33 11 4 2,5 4 6 22 13 6 86 25 14 4 27 10 10 26 8 2 16 22 10 3 25 36 11 4 35 - 50 - 70 - 95 - 120 2,5 4 6 26 15 7 102 29 16 5 32 12 10 31 10 3 16 26 12 4 25 43 13 5 35 48 12 5 50 - 70 - 95 - 120 2,5 4 28 16 8 111 32 18 5 6 35 13 2 10 - 16 - 25 - 35 - 50 - 70 - 95 - Max. number of glands/plugs Glands Side M A/B C/D 16 28 4 20 20 3 25 7 1 32 5 1 40 50 63 - Cross-section (mm²) 1,5 43 14 6 Max. number of glands/plugs Glands Side M A/B C/D 16 22 2 20 14 2 25 5 1 32 4 40 50 63 - Cross-section (mm²) 1,5 39 13 5 Max. number of glands/plugs Glands Side M A/B C/D 16 8 1 20 6 1 25 8 1 32 40 50 63 120 Max. number of glands/plugs Glands Side M A/B C/D 16 8 6 20 6 4 25 2 2 32 2 1 40 1 1 50 63 - For certificates, spare parts, light intensity diagrams, etc., please consult our website: www.ysebaert.be 1 Enclosures, terminal boxes, junction boxes 4 Terminal boxes polyester 1 CONNECTA-P series Max. number of connections = f(current, cross-section) Number of terminals = number of connections/2 Dark blue: number of terminals to be defined by manufacturer Light blue: no limit on number of terminals Type CP1222 Useful length on DIN rail = 166,5 mm CP1616 Useful length on DIN rail = 103,5 mm CP1626 Useful length on DIN rail = 205 mm CP1636 Useful length on DIN rail = 302 mm Current (A) 10 16 20 25 35 50 63 80 100 125 160 200 225 250 Current (A) 10 16 20 25 35 50 63 80 100 125 160 200 225 250 Current (A) 10 16 20 25 35 50 63 80 100 125 160 200 225 250 Current (A) 10 16 20 25 35 50 63 80 100 125 160 200 225 250 Cross-section (mm²) 1,5 46 15 6 2,5 4 30 18 8 119 34 19 5 6 37 14 2 10 36 12 4 16 30 14 5 25 50 15 6 35 56 14 6 50 - 70 - 95 - 120 - Cross-section (mm²) 1,5 48 16 7 2,5 4 32 19 9 125 36 20 6 6 39 15 2 10 38 12 4 16 32 14 5 25 - 35 - 50 - 70 - 95 - 120 2,5 4 35 20 9 136 39 22 6 6 43 16 2 10 41 13 4 16 34 16 6 25 57 17 7 35 64 16 6 50 - 70 - 95 - 120 2,5 4 35 20 9 138 40 22 6 6 43 17 2 10 42 14 4 16 35 16 6 25 58 18 7 35 65 17 7 50 - 70 - 95 - Max. number of glands/plugs Glands Side M A/B C/D 16 30 8 20 18 6 25 7 2 32 4 2 40 3 1 50 3 63 - Cross-section (mm²) 1,5 53 18 7 Max. number of glands/plugs Glands Side M A/B C/D 16 15 8 20 10 6 25 4 2 32 2 2 40 2 1 50 1 63 - Cross-section (mm²) 1,5 52 18 7 Max. number of glands/plugs Glands Side M A/B C/D 16 20 6 20 14 4 25 5 2 32 3 1 40 3 1 50 63 120 Max. number of glands/plugs Glands Side M A/B C/D 16 42 8 20 26 6 25 11 2 32 6 2 40 5 1 50 4 63 - www.ysebaert.be ● info@ysebaert.be ● T +32(0)3 328 06 60 ● F +32(0)3 328 06 80 27 1 Enclosures, terminal boxes, junction boxes 4 Terminal boxes polyester 1 CONNECTA-P series Max. number of connections = f(current, cross-section) Number of terminals = number of connections/2 Dark blue: number of terminals to be defined by manufacturer Light blue: no limit on number of terminals Type CP1656 Current (A) Useful length on DIN rail = 502 mm CP2526 Current (A) Useful length on DIN rail = 197 mm CP2526D 10 16 20 25 35 50 63 80 100 125 160 200 225 250 Current (A) Useful length on DIN rail = 197 mm CP2540 10 16 20 25 35 50 63 80 100 125 160 200 225 250 Current (A) Useful length on DIN rail = 342 mm 28 10 16 20 25 35 50 63 80 100 125 160 200 225 250 10 16 20 25 35 50 63 80 100 125 160 200 225 250 Cross-section (mm²) 1,5 53 18 7 2,5 4 35 20 9 138 40 22 9 6 43 17 2 10 42 14 4 16 35 16 6 25 58 18 7 35 65 17 7 50 - 70 - 95 - 120 - Cross-section (mm²) 1,5 70 24 10 2,5 4 47 27 13 182 52 30 8 6 57 22 3 10 56 18 6 16 46 21 8 25 76 24 10 35 85 22 9 50 - 70 - 95 - 120 2,5 4 54 31 15 211 61 34 10 6 67 26 3 10 65 21 7 16 54 25 9 25 88 27 12 35 99 26 10 50 - 70 - 95 - 120 2,5 4 50 29 14 197 57 32 9 6 62 24 3 10 60 19 6 16 50 23 9 25 82 26 11 35 92 24 9 50 24 8 70 21 7 3 Max. number of glands/plugs Glands Side M A/B C/D 16 40 27 20 24 21 25 10 8 32 7 5 40 4 3 50 3 2 63 3 2 - Cross-section (mm²) 1,5 76 26 10 Max. number of glands/plugs Glands Side M A/B C/D 16 40 27 20 24 21 25 10 8 32 7 5 40 4 3 50 3 2 63 3 2 - Cross-section (mm²) 1,5 82 28 11 Max. number of glands/plugs Glands Side M A/B C/D 16 66 8 20 40 6 25 16 2 32 10 2 40 8 1 50 6 63 95 120 19 10 5 - Max. number of glands/plugs Glands Side M A/B C/D 16 64 27 20 42 18 25 18 8 32 12 5 40 6 3 50 5 2 63 5 2 For certificates, spare parts, light intensity diagrams, etc., please consult our website: www.ysebaert.be 1 Enclosures, terminal boxes, junction boxes 4 Terminal boxes polyester 1 CONNECTA-P series Max. number of connections = f(current, cross-section) Number of terminals = number of connections/2 Dark blue: number of terminals to be defined by manufacturer Light blue: no limit on number of terminals Type CP2540D Useful length on DIN rail = 342mm CP2560 Useful length on DIN rail = 542 mm Max. section = 240mm² CP3636 Useful length on DIN rail = 329 mm CP4140 Useful length on DIN rail = 342 mm Current (A) 10 16 20 25 35 50 63 80 100 125 160 200 225 250 Current (A) 10 16 20 25 35 50 63 80 100 125 160 200 225 250 Current (A) 10 16 20 25 35 50 63 80 100 125 160 200 225 250 Current (A) 10 16 20 25 35 50 63 80 100 125 160 200 225 250 Cross-section (mm²) 1,5 87 30 12 2,5 4 58 34 16 226 65 37 11 6 71 28 4 10 69 22 7 16 57 26 10 25 95 29 12 35 106 28 11 50 28 9 70 25 9 3 95 120 21 12 6 - Cross-section (mm²) 1,5 78 27 11 2,5 4 52 30 14 202 58 33 4 6 64 25 3 10 62 20 6 16 51 24 9 25 85 26 11 35 95 25 10 50 25 8 70 22 8 3 95 120 19 11 6 59 23 14 Cross-section (mm²) 1,5 77 26 11 2,5 4 51 30 14 199 58 32 9 6 63 24 3 10 61 20 6 16 50 23 9 25 83 26 11 35 93 24 10 50 - 70 - 95 - 120 2,5 4 61 35 17 237 69 39 11 6 75 29 4 10 73 24 8 16 60 28 10 25 99 31 13 35 111 29 12 50 29 10 70 26 9 3 Max. number of glands/plugs Glands Side M A/B C/D 16 96 27 20 66 21 25 28 8 32 18 5 40 10 3 50 8 2 63 6 2 Max. number of glands/plugs Glands Side M A/B C/D 16 42 30 20 26 22 25 11 9 32 6 6 40 5 4 50 4 63 - Cross-section (mm²) 1,5 92 31 13 Max. number of glands/plugs Glands Side M A/B C/D 16 64 27 20 42 18 25 18 8 32 12 5 40 6 3 50 5 2 63 5 2 95 120 22 13 7 70 27 16 Max. number of glands/plugs Glands Side M A/B C/D 16 64 51 20 42 36 25 18 16 32 12 9 40 6 6 50 5 5 63 5 4 www.ysebaert.be ● info@ysebaert.be ● T +32(0)3 328 06 60 ● F +32(0)3 328 06 80 29 1 Enclosures, terminal boxes, junction boxes 5 Enclosures stainless steel 1 AR/AQ series The standard version of the stainless steel (316) boxes are fitted with a removable cover and closed sides. Upon request, they are also available with a hinged cover and/or gland plates. II 2 G Exe II T6/T5 II 2 G Exia IIC T6/T5 II 2 G Exe ia IIC T6/T5 II 2 D Ex tD A21 T85°C/T100°C Specifications Material Protection Seal Mounting plate Cover bolts Earthing Ambiant temperature Mounting 316 stainless steel IP66 neoprene stainless steel stainless steel, loss-free M6 bolt (internal and external) -50°C - +55°C 4 mounting eyes Zone 1 Zone 2 Zone 21 Zone 22 INERIS01ATEX0005X On request • • • • terminals entries hinged cover gland plates Ordering data Code Dimensions (hxwxd) (mm) Mounting plate (mm) AR-2 196 x 133 x 120 87 x 150 Weight 4,00 kg AR-4 266 x 196 x 135 150 x 220 7,00 kg AR-6 346 x 266 x 135 220 x 300 9,50 kg AR-8 496 x 346 x 165 300 x 450 13,00 kg AR-8A 496 x 496 x 165 450 x 450 14,50 kg AQ-6 266 x 266 x 165 220 x 220 4,50 kg AQ-8 346 x 346 x 165 300 x 300 5,75 kg Dimensional sketches 30 Product code Exterior dimensions A B C AR-2 133 196 120 AR-4 196 266 135 AR-6 266 346 135 AR-8 346 496 165 AR-8A 496 496 165 AQ-6 266 266 165 AQ-8 346 346 165 For certificates, spare parts, light intensity diagrams, etc., please consult our website: www.ysebaert.be 1 Enclosures, terminal boxes, junction boxes 5 Enclosures stainless steel 2 NXT series The boxes of the serie NXT are designed for use in difficult circumstances. These boxes have a standard version in stainless steel (316L) and are fitted II 2 G EExe II T6 with a hinged cover. II 2 G EExia IIC T6 Gland plates increases the comfort for usage. II 2 D IP66 T...°C These boxes are being tailor-made assembled under our ASSEMBL-Y certificate with terminals, pushbuttons,... Zone 1 Specifications Zone 2 Material Protection Seal Mounting plate Cover bolts Earthing Ambiant temperature (for the empty enclosure) Mounting 316L stainless steel IP66 chloroprene 2 mm thickness, painted M6 in stainless steel, loss-free M10 bolt (brass) -40°C - +80°C Zone 21 Zone 22 KEMA01ATEX2109 4 mounting eyes ø 11 mm On request • • • • gland plates terminals entries push buttons, signalling lamps, switches in cover Ordering data Code Dimensions (hxwxd) (mm) Mounting plate (mm) Number of gland plates Weight NXT221513-S-1 152 x 229 x 130 89 x 190 1 3,3 kg NXT221513-S-3 152 x 229 x 130 89 x 190 3 3,3 kg NXT262616-S-1 260 x 260 x 160 220 x 197 1 5,5 kg NXT262616-S-3 260 x 260 x 160 220 x 197 3 5,5 kg NXT262620-S-1 260 x 260 x 205 220 x 197 1 5,5 kg NXT262620-S-3 260 x 260 x 205 220 x 197 3 5,5 kg NXT303016-S-1 300 x 300 x 160 243 x 267 1 7,0 kg NXT303016-S-3 300 x 300 x 160 243 x 267 3 7,0 kg NXT303020-S-1 300 x 300 x 205 243 x 267 1 7,0 kg NXT303020-S-3 300 x 300 x 205 243 x 267 3 7,0 kg NXT382616-S-1 380 x 260 x 160 340 x 197 1 8,3 kg NXT382616-S-3 380 x 260 x 160 340 x 197 3 8,3 kg NXT382620-S-1 380 x 260 x 205 340 x 197 1 8,3 kg NXT382620-S-3 380 x 260 x 205 340 x 197 3 8,3 kg NXT453816-S-1 458 x 382 x 160 319 x 419 1 9,8 kg NXT453816-S-3 458 x 382 x 160 319 x 419 3 9,8 kg NXT453820-S-1 458 x 382 x 205 319 x 419 1 9,8 kg NXT453820-S-3 458 x 382 x 205 319 x 419 3 9,8 kg NXT484820-S-1 480 x 480 x 205 417 x 441 1 10,4 kg NXT484820-S-3 480 x 480 x 205 417 x 441 3 10,4 kg NXT503520-S-1 500 x 350 x 205 287 x 461 1 10,5 kg NXT503520-S-3 500 x 350 x 205 287 x 461 3 10,5 kg NXT624520-S-1 620 x 450 x 205 387 x 581 1 17,0 kg NXT624520-S-3 620 x 450 x 205 387 x 581 3 17,0 kg NXT745520-S-1 740 x 550 x 205 487 x 701 1 30,4 kg NXT745520-S-3 740 x 550 x 205 487 x 701 3 30,4 kg NXT765020-S-1 762 x 508 x 205 445 x 723 1 23,5 kg NXT765020-S-3 762 x 508 x 205 445 x 723 3 23,5 kg NXT866420-S-1 860 x 640 x 205 577 x 821 1 29,0 kg NXT866420-S-3 860 x 640 x 205 577 x 821 3 29,0 kg NXT916120-S-1 914 x 610 x 205 547 x 875 1 31,0 kg NXT916120-S-3 914 x 610 x 205 547 x 875 3 31,0 kg NXT987420-S-1 980 x 740 x 205 677 x 941 1 38,0 kg NXT987420-S-3 980 x 740 x 205 677 x 941 3 38,0 kg www.ysebaert.be ● info@ysebaert.be ● T +32(0)3 328 06 60 ● F +32(0)3 328 06 80 31 1 Enclosures, terminal boxes, junction boxes 5 Enclosures stainless steel 2 NXT series Dimensional sketches Product code 32 Exterior dimensions A B C Mounting plate D E Mounting F G NXT221513-S-1 152 229 130 190 98 208 152 NXT221513-S-3 152 229 130 190 98 208 152 NXT262616-S-1 260 260 160 220 197 316 170 NXT262616-S-3 260 260 160 220 197 316 170 NXT262620-S-1 260 260 205 220 197 316 170 NXT262620-S-3 260 260 205 220 197 316 170 NXT303016-S-1 306 306 160 267 243 361 203 NXT303016-S-3 306 306 160 267 243 361 203 NXT303020-S-1 306 306 205 267 243 361 203 NXT303020-S-3 306 306 205 267 243 361 203 NXT382616-S-1 380 260 160 341 197 316 250 NXT382616-S-3 380 260 160 341 197 316 250 NXT382620-S-1 380 260 205 341 197 316 250 NXT382620-S-3 380 260 205 341 197 316 250 NXT453816-S-1 458 382 160 419 319 437 305 NXT453816-S-3 458 382 160 419 319 437 305 NXT453820-S-1 458 382 205 419 319 437 305 NXT453820-S-3 458 382 205 419 319 437 305 NXT484820-S-1 480 480 205 441 417 535 327 NXT484820-S-3 480 480 205 441 417 535 327 NXT503520-S-1 500 350 205 461 287 406 350 NXT503520-S-3 500 350 205 461 287 406 350 NXT624520-S-1 620 450 205 581 387 506 450 NXT624520-S-3 620 450 205 581 387 506 450 NXT745520-S-1 740 550 205 701 487 606 540 NXT745520-S-3 740 550 205 701 487 606 540 NXT765020-S-1 762 508 205 723 445 564 508 NXT765020-S-3 762 508 205 723 445 564 508 NXT866420-S-1 860 640 205 821 577 696 570 NXT866420-S-3 860 640 205 821 577 696 570 NXT916120-S-1 914 610 205 875 547 666 559 NXT916120-S-3 914 610 205 875 547 666 559 NXT987420-S-1 980 740 205 941 677 796 700 NXT987420-S-3 980 740 205 941 677 796 700 For certificates, spare parts, light intensity diagrams, etc., please consult our website: www.ysebaert.be 1 Enclosures, terminal boxes, junction boxes 6 Junction boxes Exe plastic 1 BJE series The plastic boxes are made of polycarbonate resin with a high shock resistance. The box is supplied complete with terminals and integrated glands. Specifications Protection Material Color Mounting Ex II 2 G Exe II T6 Ex II 2 D Ex tD A21 IP66 T75°C/T80°C Zone 1 IP66 polycarbonate resin black with mounting feet Zone 2 Zone 21 Zone 22 LCIE99ATEX6003 LCIE02ATEX6069 Ordering data Code Terminals Earthing Voltage Cable entry BJE1 4 terminals connecting range per terminal: max. 2x4mm² + 2x2,5mm² min. 2x1,5mm² 4 interconnected earthing terminals connecting range per terminal: max. 1x4mm² min. 1x1mm² max. 660V BJE2-19 4 interconnected earthing 4 terminals connecting terminals connecting range per terminal: max. range per terminal: max. 3x10mm² + 1x4mm² 1x10mm² max. 690V Weight Ambiant temp. Classification 4 integrated 0,35 kg glands (8-15 mm) -50°C - +55°C Ex II 2 G Exe II T6 Ex II 2 D Ex tD A21 IP66 T75°C 4 x M25 (8-18,5 mm) -40°C - +55°C Ex II 2 G Exe II T6 Ex II 2 D Ex tD A21 IP66 T80°C 0,6 kg Dimensional sketches BJE1 BJE2-19 www.ysebaert.be ● info@ysebaert.be ● T +32(0)3 328 06 60 ● F +32(0)3 328 06 80 33 1 Enclosures, terminal boxes, junction boxes 7 Construction site boxes 1 Solid rubber The solid rubber construction site boxes are available in 2 versions: - wall-mounted version (type E50) - portable version with foot (type E70 + E80) The housings are impact-, oil-, acid- and heat-resistant and suited for outdoor installation (IP65). The distribution boxes are made according to your specifications and can be fitted with: - flange sockets - circuit breakers behind actuating flap - earth leakage protection behind actuating flap - transformers These boxes are being tailor-made assembled under our ASSEMBL-Y certificate. II 2 G Ex d e IIC T4 II 2 D Ex tD A21 IP65 T.. Zone 1 Zone 2 Zone 21 Zone 22 KEMA01ATEX2109 Specifications Protection Material Ambiant temperature IP65 solid rubber with metal frame -10°C - +40°C Ordering data Code Type Construction E50 wall single E70 portable double E80 portable single Dimensional sketches E70 E50 E80 34 For certificates, spare parts, light intensity diagrams, etc., please consult our website: www.ysebaert.be 1 Enclosures, terminal boxes, junction boxes 7 Construction site boxes 2 Cable reel Extension cords can now be readily used and neatly stored with the explosion-proof cable reel. The plastic E90 reel is available with a maximum of two sockets and a 25-metre-long cable. These cable reels are being tailor-made assembled under our ASSEMBL-Y certificate. II 2 G Exde IIC T4 Zone 1 Zone 2 Zone 21 Zone 22 KEMA01ATEX2109 Specifications Protection Material Ambiant temperature IP55 plastic -10°C - +40°C Ordering data Code Type Voltage Current E90 cable reel max. 250V max. 16A Dimensional sketches www.ysebaert.be ● info@ysebaert.be ● T +32(0)3 328 06 60 ● F +32(0)3 328 06 80 35 1 Enclosures, terminal boxes, junction boxes 7 Construction site boxes 3 Standard construction site box - type Y11138 Explosion proof construction site box type E80 in solid rubber (impact-, oil-, acid- and heat-resistant) with handle and base. The construction site box is equipped: on the entry with a 3 m rubber cable 3 x 2,5 mm² with a 230V plug, 1P+N+E and on the output with 2 sockets 12V, 2P and 1 socket 230V, 1P+N+E (= throughwired). Two transformers of 100VA/230V/12V are included. Primary as well as secondary protections are provided. The entire box is assembled and wired. This box is being tailor-made assembled under our ASSEMBL-Y certificate. II 2 G Ex d e m IIC T4 Zone 1 Zone 2 Zone 21 Zone 22 KEMA01ATEX2109 Specifications Protection Material Cable entry Output Transformer Protection transformer Ambiant temperature * Note IP65 solid rubber with metal frame 3 m rubber cable 3 x 2,5 mm² with plug 230V 1P+N+E - 2 sockets 12V 2P - 1 socket 230V 1P+N+E (troughwiring) 2x 100VA 230V/12V primary and secondary -10°C - +40°C sockets and plugs ATX (= brand) Other brands on request. Ordering data Code Type Y11138 construction site box type E80, fixed and wired Dimensional sketches 36 For certificates, spare parts, light intensity diagrams, etc., please consult our website: www.ysebaert.be 1 Enclosures, terminal boxes, junction boxes 7 Construction site boxes 4 Transformers The explosion-proof transformers of the CentaurSlamTrans series are portable and equipped with a sturdy carrying strap. They have an extreme impact resistance and weigh less than 20kg. They are available in a 200VA (10A max) and a 400VA (16A max) version, with a choice of 4 x 12VAC or 4 x 24VAC sockets (ATX, other brands upon request). The primary side is standard equipped with 10m H07RNF cable. The power supply is 230VAC, but can be 110VAC on request. The transformers are both primary and secondary protected. II 2 G Ex e mb IIC T4 Gb II 2 D Ex t IIIC T70°C Db Zone 1 Zone 2 Zone 21 Zone 22 VTT08ATEX029 Specifications Protection Material Cable entry Protection transformer Dimensions IP66 dissipative elastomer and aluminium 230VAC 10m H07RNF primary and secondary 532 x 356 x 313 mm On request • • • • • longer cable plug other brand for sockets 110VAC supply set complete with lighting fixtures Ordering data Code Supply voltage Output Transformer Current Ambiant temperature Weight CSTR200EX4C23012 230VAC 4 sockets 12V/2P 200VA 230V/12V max. 10A -20°C - +50°C 17kg CSTR200EX4C23024 230VAC 4 sockets 24V/2P 200VA 230V/24V max. 10A -20°C - +50°C 17kg CSTR400EX4C23012 230VAC 4 sockets 12V/2P 400VA 230V/12V max. 16A -20°C - +40°C 19kg CSTR400EX4C23024 230VAC 4 sockets 24V/2P 400VA 230V/24V max. 16A -20°C - +40°C 19kg www.ysebaert.be ● info@ysebaert.be ● T +32(0)3 328 06 60 ● F +32(0)3 328 06 80 37 1 Enclosures, terminal boxes, junction boxes 7 Construction site boxes 5 Standard transformer This explosion proof transformer of the CentaurSlamTrans serie is a popular version equipped with - 230V entry, 10m H07RN-F cable 3G2.5 with plug - 3 sockets 12V, 2P - 1 socket 230V, 2P+E (= throughwired). Primary as well as secondary protections are provided. The transformer is particularly suited to combine with the portable worklights on 12V. II 2 G Ex e mb IIC T4 Gb II 2 D Ex t IIIC T70°C Db Zone 1 Zone 2 Zone 21 Zone 22 VTT08ATEX029 Specifications Protection Material Cable entry Protection transformer Dimensions Ambiant temperature IP66 solid rubber with metal frame 230VAC 10m H07RN-F cable 3G2,5 with plug primary and secondary 532 x 356 x 313 mm -20°C - +40°C Ordering data 38 Code Supply voltage Output Transformer Current CSTR400EX23012/V1 230VAC - 3 sockets 12V 2P - 1 socket 230V 2P+E (troughwired, without fuse) 400VA 230V/12V max. 16A For certificates, spare parts, light intensity diagrams, etc., please consult our website: www.ysebaert.be 1 Enclosures, terminal boxes, junction boxes 8 EX-PRESS pressurized enclosures Exp 1 Serie FS850S Control unit Ex p FS850S: - compact - intelligent - economic More information in the document “EX-PRESS pressurized enclosures Exp”. Specifications Protection Material EEx p configuration (parameter input) Storage (memory) Pneumatic pressure range Switching capacity Control circuits Consumption Mounting position Ambiant temperature II 2 G Ex e mb [ib] [px] IIC T4/T6 II 2 D Ex tD [ibD] [pD] A21 IP65 T70°C Zone 1 Zone 2 Zone 21 Zone 22 BVS06ATEXE088 IP65, without outlet drill aluminium RAL7035 LC-Display, menu guided (different languages: German, English, French and Dutch) by EEPROM double saved 0 ... 18 mbar - AC: U ≤ 250VAC, l ≤ 5A at cos φ > 0,7 - DC: U ≤ 30VDC, l ≤ 5A, P ≤ 150W intrinsically sasfe Ex ib IIC (for further details see DMT 99ATEXE003) ca. 2,5VA without peripherals - position independent - only intake and outlet of the control unit should be lined up on a horizontal axis - -20°C - +45°C (T6) - -20°C - +60°C (T4) www.ysebaert.be ● info@ysebaert.be ● T +32(0)3 328 06 60 ● F +32(0)3 328 06 80 39 1 Enclosures, terminal boxes, junction boxes 8 EX-PRESS pressurized enclosures Exp 1 Serie FS850S Ordering data Code Voltage Plate orifice (mm) Range (m³/h) FS850S.0.0.W 230VAC 4 0,5 ... 1,1 FS850S.0.2.W 230VAC 6 1,1 ... 2,7 FS850S.0.4.W 230VAC 10 2,5 ... 6,5 FS850S.0.6.W 230VAC 14 6,0 ... 11,0 FS850S.0.8.W 230VAC 18 9,0 ... 15,0 FS850S.2.0.W 120VAC 4 0,5 ... 1,1 FS850S.2.2.W 120VAC 6 1,1 ... 2,7 FS850S.2.4.W 120VAC 10 2,5 ... 6,5 FS850S.2.6.W 120VAC 14 6,0 ... 11,0 FS850S.2.8.W 120VAC 18 9,0 ... 15,0 FS850S.3.0.W 110VAC 4 0,5 ... 1,1 FS850S.3.2.W 110VAC 6 1,1 ... 2,7 FS850S.3.4.W 110VAC 10 2,5 ... 6,5 FS850S.3.6.W 110VAC 14 6,0 ... 11,0 FS850S.3.8.W 110VAC 18 9,0 ... 15,0 FS850S.4.0.W 42VAC 4 0,5 ... 1,1 FS850S.4.2.W 42VAC 6 1,1 ... 2,7 FS850S.4.4.W 42VAC 10 2,5 ... 6,5 FS850S.4.6.W 42VAC 14 6,0 ... 11,0 FS850S.4.8.W 42VAC 18 9,0 ... 15,0 FS850S.5.0.W 24VAC 4 0,5 ... 1,1 FS850S.5.2.W 24VAC 6 1,1 ... 2,7 FS850S.5.4.W 24VAC 10 2,5 ... 6,5 FS850S.5.6.W 24VAC 14 6,0 ... 11,0 FS850S.5.8.W 24VAC 18 9,0 ... 15,0 FS850S.6.0.W 24VDC 4 0,5 ... 1,1 FS850S.6.2.W 24VDC 6 1,1 ... 2,7 FS850S.6.4.W 24VDC 10 2,5 ... 6,5 FS850S.6.6.W 24VDC 14 6,0 ... 11,0 FS850S.6.8.W 24VDC 18 9,0 ... 15,0 Dimensional sketches 40 For certificates, spare parts, light intensity diagrams, etc., please consult our website: www.ysebaert.be 1 Enclosures, terminal boxes, junction boxes 8 EX-PRESS pressurized enclosures Exp 1 Serie FS850S Accessories Magnetic solenoid valve and adjustable Sinter metal throttle Code Description Voltage Nozzle SVD.L.2-230VAC digital magnetic solenoid valve 42VAC 2,0 mm SVD.L.3-42VAC digital magnetic solenoid valve 42VAC 3,0 mm SVD.L.5-42VAC digital magnetic solenoid valve 42VAC 5,0 mm SVD.L.1.5-42VAC digital magnetic solenoid valve 42VAC 1,5 mm SVD.L.4-42VAC digital magnetic solenoid valve 42VAC 4,0 mm SVD.L.5-110VAC digital magnetic solenoid valve 110VAC 5,0 mm SVD.L.2-110VAC digital magnetic solenoid valve 110VAC 2,0 mm SVD.L.3-110VAC digital magnetic solenoid valve 110VAC 3,0 mm SVD.L.4-110VAC digital magnetic solenoid valve 110VAC 4,0 mm SVD.L.1-24VAC digital magnetic solenoid valve 24VAC 1,0 mm SVD.L.1-42VAC digital magnetic solenoid valve 42VAC 1,0 mm SVD.L.2-24VAC digital magnetic solenoid valve 24VAC 2,0 mm SVD.L.2-24VDC digital magnetic solenoid valve 24VAC 2,0 mm SVD.L.3-24VDC digital magnetic solenoid valve 24VAC 3,0 mm SVD.L.4-24VDC digital magnetic solenoid valve 24VAC 4,0 mm SVD.L.5-24VDC digital magnetic solenoid valve 24VAC 5,0 mm SVD.L.1.5-24VDC digital magnetic solenoid valve 24VAC 1,5 mm SVD.L.1-24VDC digital magnetic solenoid valve 24VAC 1,0 mm SVD.L.1.5-110VAC digital magnetic solenoid valve 110VAC 1,5 mm SVD.L.3-24VAC digital magnetic solenoid valve 24VAC 3,0 mm SVD.L.4-24VAC digital magnetic solenoid valve 24VAC 4,0 mm SVD.L.5-24VAC digital magnetic solenoid valve 24VAC 5,0 mm SVD.L.1.5-24VAC digital magnetic solenoid valve 24VAC 1,5 mm SVD.L.1-110VAC digital magnetic solenoid valve 110VAC 1,0 mm SVD.L.4-230VAC digital magnetic solenoid valve 230VAC 4,0 mm SVD.L.5-230VAC digital magnetic solenoid valve 230VAC 5,0 mm SVD.L.3-230VAC digital magnetic solenoid valve 230VAC 3,0 mm SVD.L.2-230VAC digital magnetic solenoid valve 230VAC 2,0 mm SVD.L.1-230VAC digital magnetic solenoid valve 230VAC 1,0 mm SVD.L.1-120VAC digital magnetic solenoid valve 120VAC 1,0 mm SVD.L.1.5-230VAC digital magnetic solenoid valve 230VAC 1,5 mm SVD.L.1.5-120VAC digital magnetic solenoid valve 120VAC 1,5 mm SVD.L.4-120VAC digital magnetic solenoid valve 120VAC 4,0 mm SVD.L.5-120VAC digital magnetic solenoid valve 120VAC 5,0 mm SVD.L.2-120VAC digital magnetic solenoid valve 120VAC 2,0 mm SVD.L.3-120VAC digital magnetic solenoid valve 120VAC 3,0 mm SVP.5-110VAC proportional magnetic solenoid valve 110VAC > 300 l SVP.3-110VAC proportional magnetic solenoid valve 110VAC 300 l SVP.3-120VAC proportional magnetic solenoid valve 120VAC 300 l SVP.5-230VAC proportional magnetic solenoid valve 230VAC > 300 l SVP.3-42VAC proportional magnetic solenoid valve 42VAC 300 l SVP.5-120VAC proportional magnetic solenoid valve 120VAC > 300 l SVP.5-24VAC proportional magnetic solenoid valve 24VAC > 300 l SVP.3-230VAC proportional magnetic solenoid valve 230VAC 300 l SVP.5-24VDC proportional magnetic solenoid valve 24VAC > 300 l SVP.3-24VDC proportional magnetic solenoid valve 24VAC 300 l SVP.3-24VAC proportional magnetic solenoid valve 24VAC 300 l SVP.5-42VAC proportional magnetic solenoid valve 42VAC > 300 l Fuse Code Current Voltage Valve SI850.0 100 mA 230VAC SVD SI850.1 160 mA 120-110VAC SVD SI850.2 200 mA 230VAC SVP SI850.3 315 mA 110VAC-120VAC SVP SI850.5 630 mA 24VDC-24VAC SVD SI850.7 1600 mA 24VDC-24VAC SVP www.ysebaert.be ● info@ysebaert.be ● T +32(0)3 328 06 60 ● F +32(0)3 328 06 80 Housing volume 41 1 Enclosures, terminal boxes, junction boxes 42 8 EX-PRESS pressurized enclosures Exp 1 Serie FS850S Control unit Code Type Classification BT851.0 intelligent operation panel for mounting on the front Ex ib IIC T6 BT851.5 intelligent operation panel in fieldhousing Ex ib IIC T6 BT854.0 operation panel for mounting on the front Ex ib IIC T6 BT854.1 operation panel for mounting on the front with key-operated switch Ex ib IIC T6 BT855.0 operation panel in fieldhousing Ex ib IIC T6 BT855.1 operation panel in fieldhousing with key-operated switch Ex ib IIC T6 For certificates, spare parts, light intensity diagrams, etc., please consult our website: www.ysebaert.be 1 Enclosures, terminal boxes, junction boxes 8 EX-PRESS pressurized enclosures Exp 2 Serie FS840 The use of pressurized enclosures allows the operation of ‘non explosion protected’ devices in hazardous areas zone 2 and 22. The protection type ‘pressurisation’ is based on the principle of maintaining a constant pressure using air or a protective gas to prevent an explosive mixture forming near the apparatus inside the pressurized enclosure. More information in the document “Reduced Pressurized System ExnP”. Specifications II 3 G Ex nAC [pz] IIC T6 II 3 D Ex [pD 22] IP54 T70°C Zone 1 Zone 2 Zone 21 Zone 22 TUV03ATEX2095X Protection Material EEx p configuration (parameter input) Storage (memory) Pneumatic pressure range Switching capacity Consumption Mounting position Ambiant temperature IP65, without outlet drill aluminium RAL7035 LC-Display, menu guided (different languages: German, English, French and Dutch) by EEPROM double saved 0 ... 22 mbar - AC: U ≤ 250VAC, l ≤ 5A (AC1), P ≤ 1500VA - DC: U ≤ 30VDC, l ≤ 4A, P ≤ 150W ca. 2VA without peripherals position independent (see drawings) - -20°C - +40°C (T6) - -20°C - +60°C (T5) Ordering data Code Voltage FS840.0 230VAC FS840.2 115VAC FS840.6 24VDC www.ysebaert.be ● info@ysebaert.be ● T +32(0)3 328 06 60 ● F +32(0)3 328 06 80 43 1 Enclosures, terminal boxes, junction boxes 8 EX-PRESS pressurized enclosures Exp 2 Serie FS840 Dimensional sketches Accessories Magnetic solenoid valve and adjustable Sinter metal throttle Code Description 44 Voltage Nozzle digital magnetic solenoid valve 42VAC 2,0 mm digital magnetic solenoid valve 42VAC 3,0 mm SVD.L.5-42VAC digital magnetic solenoid valve 42VAC 5,0 mm SVD.L.1.5-42VAC digital magnetic solenoid valve 42VAC 1,5 mm SVD.L.4-42VAC digital magnetic solenoid valve 42VAC 4,0 mm SVD.L.5-110VAC digital magnetic solenoid valve 110VAC 5,0 mm SVD.L.2-110VAC digital magnetic solenoid valve 110VAC 2,0 mm SVD.L.3-110VAC digital magnetic solenoid valve 110VAC 3,0 mm SVD.L.4-110VAC digital magnetic solenoid valve 110VAC 4,0 mm SVD.L.1-24VAC digital magnetic solenoid valve 24VAC 1,0 mm SVD.L.1-42VAC digital magnetic solenoid valve 42VAC 1,0 mm SVD.L.2-24VAC digital magnetic solenoid valve 24VAC 2,0 mm SVD.L.2-24VDC digital magnetic solenoid valve 24VAC 2,0 mm SVD.L.3-24VDC digital magnetic solenoid valve 24VAC 3,0 mm SVD.L.4-24VDC digital magnetic solenoid valve 24VAC 4,0 mm SVD.L.5-24VDC digital magnetic solenoid valve 24VAC 5,0 mm SVD.L.1.5-24VDC digital magnetic solenoid valve 24VAC 1,5 mm SVD.L.1-24VDC digital magnetic solenoid valve 24VAC 1,0 mm SVD.L.1.5-110VAC digital magnetic solenoid valve 110VAC 1,5 mm SVD.L.3-24VAC digital magnetic solenoid valve 24VAC 3,0 mm SVD.L.4-24VAC digital magnetic solenoid valve 24VAC 4,0 mm SVD.L.5-24VAC digital magnetic solenoid valve 24VAC 5,0 mm SVD.L.1.5-24VAC digital magnetic solenoid valve 24VAC 1,5 mm SVD.L.1-110VAC digital magnetic solenoid valve 110VAC 1,0 mm SVD.L.4-230VAC digital magnetic solenoid valve 230VAC 4,0 mm SVD.L.5-230VAC digital magnetic solenoid valve 230VAC 5,0 mm SVD.L.3-230VAC digital magnetic solenoid valve 230VAC 3,0 mm SVD.L.2-230VAC digital magnetic solenoid valve 230VAC 2,0 mm SVD.L.1-230VAC digital magnetic solenoid valve 230VAC 1,0 mm SVD.L.1-120VAC digital magnetic solenoid valve 120VAC 1,0 mm SVD.L.1.5-230VAC digital magnetic solenoid valve 230VAC 1,5 mm SVD.L.1.5-120VAC digital magnetic solenoid valve 120VAC 1,5 mm SVD.L.4-120VAC digital magnetic solenoid valve 120VAC 4,0 mm SVD.L.5-120VAC digital magnetic solenoid valve 120VAC 5,0 mm SVD.L.2-120VAC digital magnetic solenoid valve 120VAC 2,0 mm SVD.L.3-120VAC digital magnetic solenoid valve 120VAC 3,0 mm SD840 adjustable Sinter metal throttle SVD.L.2-230VAC SVD.L.3-42VAC Housing volume For certificates, spare parts, light intensity diagrams, etc., please consult our website: www.ysebaert.be 2 Assembled housings 1 Production quality assurance notification according to ATEX ...................... 47 2 CONNECTA-P : Terminal boxes Exe/Exi ..................................................... 48 3 ASSEMBL-Y : Exe housings with components ............................................ 49 4 EJB-Y : ExdIIB control and distributionpanels.............................................. 51 5 GUB-Y / EMH-Y : ExdIIC control and distributionpanels.............................. 53 6 EX-PRESS : Enclosures (systems) Exp ...................................................... 55 7 Various solutions .......................................................................................... 57 www.ysebaert.be ● info@ysebaert.be ● T +32(0)3 328 06 60 ● F +32(0)3 328 06 80 45 2 Assembled housings 1 Production quality assurance notification according to ATEX Our moto? Strong in custom-made equipment! With our knowledge and know-how, Ysebaert can provide a customer-oriented solution time and again. Protection methods Ysebaert provides enclosures which are suited for gas and dust environments. Common protection methods are Exd, Exp, ExpD, Exe, ExtD, Exi and their mutual combinations. Certification All our assembled enclosures have the EC type-examination certificate, category 2G/2D (zone 1/21) or 1G/1D (zone 0/20) if applicable. This total certificate comprises the empty enclosure, the mechanical process, the built-in components and the wiring. The enclosures also bear the obligatory CE mark and the number, referring to our production quality assurance certificate. Production Our strongest assets are the expert knowledge of our employees and our state-of-the-art machinery. Thanks to our large stock of empty enclosures and components, your order is always delivered promptly and correctly. Testing facilities To guarantee the quality of our assembled enclosures, Ysebaert makes use of testing facilities such as: - high-voltage testers - test gases (helium, carbon dioxide) and analysers for purging tests - impact test set-up - temperature metres to determine the temperature class - ring and plug gauges to check the threads - test switchboard with adjustable power supplies Mechanical workshop with CNC machnining centers Engineering and production co-ordination Piecework but also series production Wiring acitivities www.ysebaert.be ● info@ysebaert.be ● T +32(0)3 328 06 60 ● F +32(0)3 328 06 80 47 2 Assembled housings 2 CONNECTA-P : Terminal boxes Exe/Exi CONNECTA-P : Terminal boxes Exe/Exi The CONNECTA-P series terminal boxes are made of glassfibre-reinforced polyester and offers the best price-quality ratio for terminal boxes in hazardous areas. This comprehensive series is available for dust environments and for Exe and Exi applications and can be delivered within 48 hours. As a standard our boxes are equiped with Phoenix terminals andWiska polyamide cable glands (metric Exe or Exi). On request any other brand of terminals or cable glands can be used when ATEX approved. When metal glands are used Threaded earth plates provide a safe earth continuity . CONNECTA-P terminal box Exi with glands and removable plugs CONNECTA-P terminal box in Exe version CONNECTA-P terminal box Exi with screenterminals and earthrail CONNECTA-P terminal box Exe II T6 with brass glands and threaded earth plates EExe 48 For certificates, spare parts, light intensity diagrams, etc., please consult our website: www.ysebaert.be 2 Assembled housings 3 ASSEMBL-Y : Exe housings with components ASSEMBL-Y : Applications with increased safety enclosures (Exe) General Only certified components may be installed in enclosures with an increased safety (Exe). This means that terminals, pushbuttons, lights, automatic fuses, etc. require a component certificate before they can be installed in an Exe enclosure. These components are not always readily available, resulting in longer delivery periods. One advantage compared to Exd enclosures is the user-friendliness when installing and maintaining these components. Classification Boxes in which only terminals are installed, are given the classification Exe II; if Exd components are also installed, the classification becomes Exed IIC (or IIB or IIA). As in the case of EExd, the temperature class is mostly T6, unless determined otherwise in the certificate. Certification Thanks to our framework certificate, Ysebaert can always offer you creative, certified solutions which perfectly meet your wishes. As an independant manufacturerwe can use and combinecomponents of different manufacturers to one optimal technical solution at a competitive price; all this of course with a complete certificate of conformity. EX-EMPTY-1/21 This series of tailor-made housings in SS304 (or SS316) distinguishes itself for its almost unlimited dimensions and possibilities to create special designs (max wxhxd = 4x3x2m). Examples: - A detached housing with pedestal and dimensions wxhxd = 1,2 x 2 x 0,5 m - A writing desk made following your drawings - A commander housing with doors at the back (suited for building-in in a wall) - A “real” IP66 housing for outdoor installation of offshore applications The unique concept of double bit cam locks located outside the area of the sealing, combined with round-welded corners is deduced from our Exp-housings EX-PRESS-1/21 and guarantees an IP66 protection degree. Classification of the empty housing: II 2 G Ex e II II 2 D Ex tD A21 IP66 Choice of materials Enclosures with increased safety are mostly made of plastic (polyester, polycarbonate resin, etc.), but also aluminium, steel or stainless steel are regularly used. When used as a construction site box, solid rubber is also used. Applications Applications where Exe boxes are used: - terminal boxes - control boxes (pushbuttons, lights, switches) - transformers - distribution boards (with automatic switches) - construction site boxes with sockets and fuses Bottom side of stainless steel interface panel with polyamide glands and plugs Inside view of a distribution board with Exe housings and Exde circuit breakers. Housing Exe series NEXT with terminals and nickel plated glands and plugs www.ysebaert.be ● info@ysebaert.be ● T +32(0)3 328 06 60 ● F +32(0)3 328 06 80 49 2 Assembled housings 3 ASSEMBL-Y : Exe housings with components Control panel Exdem with stainless steel housing Interface panel Ex II2G Exde[ib]IICT4 Distributionpanel ExdeIICT4 Construction site box Ex II2G ExdeIICT4 with automatic circuitbreakers Cable reel ExdeIICT6 Control panel Exde with synoptic Control panel Exde, housing glassfibre reinforced polyester Stainless steel housing with digital displays Exi Stainless steel housing with digital display Exi 50 For certificates, spare parts, light intensity diagrams, etc., please consult our website: www.ysebaert.be 2 Assembled housings 4 EJB-Y : ExdIIB control and distributionpanels EJB-Y : Control and distributionpanels ExdIIB+H2 General Standard equipment may be installed in explosion-proof enclosures. Due to the wide-ranging availability of components such as magnetic switches, automatic fuses, motor circuit breakers, etc. Exd control boxes can be readily constructed. Components that need to be replaced after some time, are fairly easily available, which makes the storage of a variety of special parts superfluous. The components within the box can be controlled externally by means of explosion-proof passing troughs/handles; these are used, for instance, to rearm automatic fuses or earth leakage protections. To allow for built-in instruments, the box’s cover is fitted with a rectangular or round window. This way, the instruments are visible without having to open the box. For the assembly of larger switchboards the Exd boxes are electrically interconnected by means of seals and mounted on a frame. For more information on our empty enclosures, please consult chapter 1.1.1. Classification Boxes with a bolted cover like the series EJB-Y usually have classification Exd IIB. In most cases the temperature class is T6, unless components are built in that generate a lot of heat. When e.g. transformers are installed, the temperature class will be redefined based on the dissipated output. So, when components are built in, the limit values mentioned in the certificate and its addenda need to be taken into account. Choice of materials Explosion-proof boxes series EJB-Y are made of aluminium or stainless steel. In addition, a protective coat of paint is applied. Applications Applications where Exd boxes are used: - distribution boards - instrument enclosures - terminal boxes - control boxes - relay and PLC controls - motor controls (safeties) - transformers - Exi modules - electronics - customer-specific components Inside view of an control box ExdIIB Control box ExdIIB Control box ExdIIB with window www.ysebaert.be ● info@ysebaert.be ● T +32(0)3 328 06 60 ● F +32(0)3 328 06 80 51 2 Assembled housings 4 EJB-Y : ExdIIB control and distributionpanels Inside view of control box ExdIIB with window Inside view of an control box stainless steel 316 ExdIIB Inside view of an control box ExdIIB with HT transformer Inside view of control box ExdIIB with PLC Control box stainless steel 316 ExdIIB Control box ExdIIB - bottom view Application on site 52 For certificates, spare parts, light intensity diagrams, etc., please consult our website: www.ysebaert.be 2 Assembled housings 5 GUB-Y / EMH-Y : ExdIIC control and distributionpanels GUB-Y : Control and distributionpanels ExdIIC General Standard equipment may be installed in explosion-proof enclosures. Due to the wide-ranging availability of components such as magnetic switches, automatic fuses, motor circuit breakers, etc. Exd control boxes can be readily constructed. Components that need to be replaced after some time, are fairly easily available, which makes the storage of a variety of special parts superfluous. The components within the box can be controlled externally by means of explosion-proof passing troughs/handles; these are used, for instance, to rearm automatic fuses or earth leakage protections. To allow for built-in instruments, the box’s cover is fitted with a rectangular or round window. This way, the instruments are visible without having to open the box. For the assembly of larger switchboards the Exd boxes are electrically interconnected by means of seals and mounted on a frame. For more information on the empty enclosures, please consult: chapter 1.2.1 for GUB-Y and chapter 1.2.2 for EMH-Y. Classification Boxes with ascrew cover usually have classification Exd IIC. In most cases the temperature class is T6, unless components are built in that generate a lot of heat. When e.g. transformers are installed, the temperature class will be redefined based on the dissipated output. So, when components are built in, the limit values mentioned in the certificate and its addenda need to be taken into account. Combination with Exe box Explosion-proof boxes can be combined with an Exe connection and control box. This is mainly the case for Exd IIC boxes with external controls (switches, pushbuttons, etc.); these control components are hard to fit in a screw cover. The terminals and controls are then mounted on the built-on Exe box. This box is electrically and mechanically connected to the Exd box by means of explosion-proof bushings. In certain instances, however, controls can be fitted in a screw cover (IIC enclosure) by mounting a combined flange. Choice of materials Explosion-proof boxes series GUB-Y are made of aluminium; in addition, a protective coat of paint is applied. Applications Applications where Exd boxes are used: - distribution boards - instrument enclosures - terminal boxes - control boxes - relay and PLC controls - motor controls (safeties) - transformers - Exi modules - electronics - customer-specific components Control box ExdIIC Inside view of a control box ExdIIC Inside view of a control box ExdIIC www.ysebaert.be ● info@ysebaert.be ● T +32(0)3 328 06 60 ● F +32(0)3 328 06 80 53 2 Assembled housings 5 GUB-Y / EMH-Y : ExdIIC control and distributionpanels Inside view of a control box ExdIIC Control box ExdIIC series EMH with window Inside view of a control box ExdIIC 54 For certificates, spare parts, light intensity diagrams, etc., please consult our website: www.ysebaert.be 2 Assembled housings 6 EX-PRESS : Enclosures (systems) Exp EX-PRESS : Pressurized housings (systems) Exp General The Exp protection method is usually opted for when large and bulky devices, special devices and/or heat-generating apparatuses need to be installed. Exp boxes tend to have an easier access than Exd boxes. If gas group IIC is required, Exp is opted for, because Exd IIC enclosures are insufficiently large. Of course, compressed air or an inert gas is required for this protection method. For more information about the different components of an Exp-system, please consult chapter 1.8.1. For simplified presurized enclosures for zone 2, please consult chapter 1.8.2. Classification In most instances an Exp system has a combined classification. A system complete with box and keyboard, for instance, has classification Ex p ib IIC T4. An ATEX certificate for a complete assembly delivered by a Notified Body is a demand of directive 94/9/EG for zone 1 and 21 (category 2G and 2D). Thanks to our framework certificate and comprehensive testing facilities, we can always offer you a creative, certified solution. Choice of materials The Exp enclosure is usually made of stainless steel. Great care is required for the air-tightness and mechanical strength of the box. Applications Applications where an Exp overpressure system is used: - installation of analysers - installation of computers (screen visible behind glass) - installation of displays/monitors - large equipment Inside view of a mobile unit with pressurized system Pressurized system with computersystem Pressurized panel on site www.ysebaert.be ● info@ysebaert.be ● T +32(0)3 328 06 60 ● F +32(0)3 328 06 80 55 2 Assembled housings 6 EX-PRESS : Enclosures (systems) Exp Detail of the control unit Inside view of a pressurized panel with control unit inside Pressurized panel on site Special housing for integration into a wall Exp panel Exp panel Inside view of Exp housing Rittal with built-in PC Exp housing Rittal with built-in PC 56 For certificates, spare parts, light intensity diagrams, etc., please consult our website: www.ysebaert.be 2 Assembled housings 7 Various solutions Various solutions General Our longstanding experience inexplosion safety together with our certified Production Quality Assurance System gives us the opportunity to assemble control and distribution panels under the responsibility of other manufacturers. In this case the assembled housings are supplied with a label and CE-declaration of the relevant manufacturer. In this case we can offer less recurrent solutions according to customer requirements without a time consuming and expensive approval procedure. For examples we refer to the pictures section. Housing ExdIICT6 Housing ExdeIICT6 with integrated UPS (Uninterruptable Power Supply) Exd housing with built-on Exe box Housing ExdeIICT6 with window www.ysebaert.be ● info@ysebaert.be ● T +32(0)3 328 06 60 ● F +32(0)3 328 06 80 57 3 Lighting 1 Fluorescent lamp fittings for zone 1, 2, 21 and 22 ....................................... 61 1 2 3 4 5 2 Surface - polyester enclosure - e84 .................................................. 61 Surface - polyester enclosure - e15 .................................................. 62 Surface/recessed - steelplate enclosure ........................................... 64 Surface - aluminium enclosure - maintenance free .......................... 66 Surface mounting - flameproof enclosure ......................................... 67 Fluorescent lamp fittings for zone 2 and 22 ................................................. 68 1 nD16 series ....................................................................................... 68 3 Emergency lighting for zone 1, 2, 21 and 22 ............................................... 69 1 Surface mounting - polyester enclosure ........................................... 69 2 Surface mounting - flameproof enclosure ......................................... 70 4 Emergency lighting for zone 2 and 22 ......................................................... 71 1 nD16 series ....................................................................................... 71 5 Induction lightingQL85, ENDURA ................................................................ 72 1 Endura 150W .................................................................................... 72 2 QL85/165W ....................................................................................... 73 6 Autonomous safety lighting for zone 1, 2, 21 and 22 ................................... 74 1 8860 series ....................................................................................... 74 7 Floodlights for zone 1, 2, 21 en 22 ............................................................... 75 1 FL series - IIB+H2 ............................................................................. 75 2 d3000 / d4000 series - IIC................................................................. 76 8 Floodlights for zone 2 and 22 ....................................................................... 77 1 nD27 series ....................................................................................... 77 9 Autonomous hand lamps ............................................................................. 78 1 Type HS4EX ..................................................................................... 78 2 Type KS-8650 ................................................................................... 79 www.ysebaert.be ● info@ysebaert.be ● T +32(0)3 328 06 60 ● F +32(0)3 328 06 80 59 10 Portable lamps and floodlights ..................................................................... 80 1 2 3 4 5 6 KHLE 70EN - 12/24/42V series for zone 1 and 2 ............................. 80 Portable lamps - 24V/230V for zone 1, 2, 21 and 22 ........................ 81 Portable floodlight for zone 1, 2, 21 and 22 ...................................... 82 Portable worklight for zone 1 ............................................................ 83 Portable worklight for zone 1, 2, 21 and 22 ...................................... 84 Inspection lighting for zone 1, 2, 21 and 22 ...................................... 86 11 Suspension fittings ....................................................................................... 87 1 EVde series....................................................................................... 87 12 Tank inspection lighting ................................................................................ 89 1 USL06 series .................................................................................... 89 2 USL07 series .................................................................................... 90 13 Back lights for level gauges ......................................................................... 91 1 TNCLS series.................................................................................... 91 60 For certificates, spare parts, light intensity diagrams, etc., please consult our website: www.ysebaert.be 3 Lighting 1 Fluorescent lamp fittings for zone 1, 2, 21 and 22 1 Surface - polyester enclosure - e84 These fluorescent lamp fittings are suited for standard fluorescent lamps (2 pins) and provided with an electronic 2-channel ballast. The electronic ballast switches off at the end of the lamplife (according to IEC 61347-2-3). With its central locking system the fitting can be readily and safely opened, as the special prism cover is fitted with hinges. The standard version of the fittings includes 3 cable glands, making throughwiring possible on one or two sides. Various accessories are available as an option to mount the fitting. II 2 G Ex d e q IIC T4 II 2 D Ex tD A21 IP66 T80°C Zone 1 Zone 2 Mounting Impact Zone 21 Zone 22 PTB09ATEX2039 PTB07ATEX2040 Specifications Housing Cover Reflector Protection Electronic ballast Electrical connection Voltage Lamp holder Switch Cable entry PTB09ATEX2031 glass-fibre reinforced polyester polycarbonate resin, with prism optics glass-fibre reinforced polyester, white, hinged IP66 Exeq, cos φ 0,95, 2-channel 3P terminal block (max. 6mm²) 220-240VAC/DC - 50/60Hz TLD (2 pins) Exd 3 M25 entries (complete with 2 glands and 1 plug), suited for throughwiring by means of 2 threaded bushes M8 for: - ceiling/wall mounting - chain mounting - pipe mounting 20 Joule On request • • throughwiring (2 terminal blocks) other cable entries Ordering data Code Power Weight Ambiant temperature e840118 1x18W 5,3 kg -20°C - +55°C e840218 2x18W 5,4 kg -20°C - +55°C e840136 1x36W 7,5 kg -20°C - +60°C e840236 2x36W 7,6 kg -20°C - +55°C e840158 1x58W 9,2 kg -20°C - +55°C e840258 2x58W 9,2 kg -20°C - +55°C Dimensional sketches Product code Dimensions A B e840118 400 745 e840218 400 745 e840136 700 1355 e840236 700 1355 e840158 700 1655 e840258 700 1655 www.ysebaert.be ● info@ysebaert.be ● T +32(0)3 328 06 60 ● F +32(0)3 328 06 80 61 3 Lighting 1 Fluorescent lamp fittings for zone 1, 2, 21 and 22 2 Surface - polyester enclosure - e15 These fluorescent lamp fittings are suited for standard fluorescent lamps (2 pins) and provided with a 2-channel electronic ballast. The electronic ballast switches off at the end of the lamplife (according to IEC 61347-2-3). With its central locking system the fitting can be readily and safely opened, as the special prism cover is fitted with hinges. The standard version of the fittings includes 3 cable glands, making throughwiring possible on one or two sides. Various accessories are available as an option to mount the fitting. II 2 G Ex d e q IIC T4 (*T6) II 2 D Ex tD A21 IP66 T80°C Zone 1 Zone 2 Zone 21 Zone 22 PTB97ATEX2223 PTB97ATEX2224 PTB97ATEX2225 Specifications Housing Cover Reflector Protection Electronic ballast Electrical connection Voltage Lamp holder Switch Cable entry Mounting Impact * Note glass-fibre reinforced polyester polycarbonate resin, with prism optics glass-fibre reinforced polyester, white, hinged IP66 Exeq, cos φ 0,95, 2-channel 3P terminal block (max. 6mm²) 220-240VAC/DC - 50/60Hz TLD (2 pins) EExd 3 M25 entries (complete with 2 glands and 1 plug), suited for throughwiring • by means of 2 threaded bushes M8 for: - ceiling/wall mounting - chain mounting - pipe mounting • tube mounting ø 42 mm 20 Joule Type e 15221 (1x20W) and e 15222 (2x20W) are available on request with temperature class T6. In this case Ø 38 mm lamps need to be used and the ambient temperature must not be higher than 40°C. On request • • • throughwiring (2 terminal blocks) three-phase connection voltage 110-254 VCA/110-230 VCC Ordering data 62 Code Power Weight Mounting Ambiant temperature e15221 1x18W 7,5 kg 2x M8 threaded bushings -20°C - +60°C e15222 2x18W 8,0 kg 2x M8 threaded bushings -20°C - +60°C e15241 1x36W 10,2 kg 2x M8 threaded bushings -20°C - +60°C e15242 2x36W 10,7 kg 2x M8 threaded bushings -20°C - +60°C e15261 1x58W 13,5 kg 2x M8 threaded bushings -20°C - +50°C e15262 2x58W 14,0 kg 2x M8 threaded bushings -20°C - +50°C e15221PM 1x18W 10,0 kg pole mounting -20°C - +50°C e15222PM 2x18W 10,5 kg pole mounting -20°C - +50°C e15241PM 1x36W 13,0 kg pole mounting -20°C - +50°C e15242PM 2x36W 13,5 kg pole mounting -20°C - +50°C e15261PM 1x58W 13,5 kg pole mounting -20°C - +50°C e15262PM 2x58W 14,0 kg pole mounting -20°C - +50°C For certificates, spare parts, light intensity diagrams, etc., please consult our website: www.ysebaert.be 3 Lighting 1 Fluorescent lamp fittings for zone 1, 2, 21 and 22 2 Surface - polyester enclosure - e15 Dimensional sketches e15-PM e15 Product code Dimensions A B e15221 600 786 e15222 600 786 e15241 800 1396 e15242 800 1396 e15261 800 1696 e15262 800 1696 e15221PM 260 786 e15222PM 260 786 e15241PM 410 1396 e15242PM 410 1396 e15261PM 410 1696 e15262PM 410 1696 www.ysebaert.be ● info@ysebaert.be ● T +32(0)3 328 06 60 ● F +32(0)3 328 06 80 63 3 Lighting 1 Fluorescent lamp fittings for zone 1, 2, 21 and 22 3 Surface/recessed - steelplate enclosure These fluorescent lamp fittings are suited for standard fluorescent lamps (2 pins) and provided with an electronic ballast. The electronic ballast switches off at the end of the lamplife (according to IEC 61347-2-3). With its central locking system the fitting can be readily and safely opened, as the cover is fitted with hinges. This fitting is also suitable for mounting in a spraying booth. II 2 G Ex d e q IIC T4 (T6*) II 2 D Ex tD A21 IP65 T80°C Zone 1 Zone 2 Zone 21 Zone 22 IBExU02ATEX1018 Specifications Housing Cover Reflector Protection Electronic ballast Electrical connection Voltage Lamp holder Switch Cable entry Mounting * Note steelplate, powder coating, light grey (RAL7035) safety glass, hinged steelplate, white, hinged IP65 Exeq, cos φ 0,95 3P terminal block (max. 6 mm²) 220-240VAC/DC - 50/60Hz TLD (2 pins) Exd with optical indication of switch position 3 M25 entries (complete with 2 glands and 1 plug) - 2 suspension eyes (H8VP) - 2 ceiling clamps (15AP) - recessed frame (EB) - swivelling arm (SA181/182) Type e18121EVG and e18122EVG are also available on request with temperature class T6. In this case Ø 38 mm lamps need to be used. On request • • • throughwiring three-phase connection version for zone 2 and 22 Ordering data 64 Code Power Housing Weight Mounting Ambiant temperature e18121EVG 1x18W small 11,0 kg 2 x M8 threaded bushings -20°C - +50°C e18122EVG 2x18W small 11,0 kg 2 x M8 threaded bushings -20°C - +50°C e18123EVG 3x18W small 13,0 kg 2 x M8 threaded bushings -20°C - +40°C e18141EVG 1x36W small 19,0 kg 2 x M8 threaded bushings -20°C - +50°C e18142EVG 2x36W small 19,0 kg 2 x M8 threaded bushings -20°C - +50°C e18143EVG 3x36W small 21,0 kg 2 x M8 threaded bushings -20°C - +40°C e18161EVG 1x58W small 22,0 kg 2 x M8 threaded bushings -20°C - +50°C e18162EVG 2x58W small 22,0 kg 2 x M8 threaded bushings -20°C - +50°C e18163EVG 3x58W small 24,0 kg 2 x M8 threaded bushings -20°C - +40°C e18223EVG 3x18W large 16,0 kg 2 x M8 threaded bushings -20°C - +40°C e18224EVG 4x18W large 16,0 kg 2 x M8 threaded bushings -20°C - +40°C e18243EVG 3x36W large 24,0 kg 2 x M8 threaded bushings -20°C - +40°C e18244EVG 4x36W large 24,0 kg 2 x M8 threaded bushings -20°C - +40°C e18263EVG 3x58W large 29,0 kg 2 x M8 threaded bushings -20°C - +40°C e18264EVG 4x58W large 29,0 kg 2 x M8 threaded bushings -20°C - +40°C For certificates, spare parts, light intensity diagrams, etc., please consult our website: www.ysebaert.be 3 Lighting 1 Fluorescent lamp fittings for zone 1, 2, 21 and 22 3 Surface/recessed - steelplate enclosure Dimensional sketches Product code Dimensions a b c d e f g h e18121EVG 324 740 786 93 300 373 720 520 e18122EVG 324 740 786 93 300 373 720 520 e18123EVG 324 740 786 93 300 373 720 520 e18141EVG 324 1350 1396 98 400 373 1330 1050 e18142EVG 324 1350 1396 98 400 373 1330 1050 e18143EVG 324 1350 1396 98 400 373 1330 1050 e18161EVG 324 1650 1696 48 400 373 1630 1350 e18162EVG 324 1650 1696 48 400 373 1630 1350 e18163EVG 324 1650 1696 48 400 373 1630 1350 e18223EVG 388 740 786 93 300 437 720 520 e18224EVG 388 740 786 93 300 437 720 520 e18243EVG 388 1350 1396 98 400 437 1330 1050 e18244EVG 388 1350 1396 98 400 437 1330 1050 e18263EVG 388 1650 1696 48 400 437 1630 1350 e18264EVG 388 1650 1696 48 400 437 1630 1350 www.ysebaert.be ● info@ysebaert.be ● T +32(0)3 328 06 60 ● F +32(0)3 328 06 80 65 3 Lighting 1 Fluorescent lamp fittings for zone 1, 2, 21 and 22 4 Surface - aluminium enclosure - maintenance free These fluorescent lamp fixtures are fitted with pre-mounted long life lamps. The patented combination of fitting and lamps gives a 10 years operational warranty. The sealed-for-life concept guarantees a high IP-degree. The tempered glass cover will not discolour which provides a high light output efficiency. Electrical connection can be made via spring terminals in the integrated external junction box. The electronic ballast switches off at the end of the lamplife (EOL). Two brackets on a guidance rail assure an easy and quick installation. Brackets for pole, ceiling or suspension mounting are available as an option. II 2 G Ex e mb II T6 II 2 D Ex tD A21 IP66 T80°C Zone 1 Zone 2 Zone 21 Zone 22 KEMA08ATEX0163 Specifications Housing Cover Protection Electronic ballast Electrical connection Voltage Colour temperature Life Cable entry Mounting Ambiant temperature seawater resistant anodized aluminium tempered glass IP66 Exeq, cos φ 0,95 spring terminals in external junction box (max. 6 mm²) 220-264VAC - 50/60Hz 4000K 10 years (guaranteed mimimum) 2 x M25 entries 2 brackets on guidance rail -20°C - +55°C On request • • • • • 110/120VAC - 50/60Hz color temperature 3000K throughwiring emergency lighting frame for recessed installation Ordering data Code Power Light intensity Weight TNAML218 2x18W 2600 lumen 6,6 kg TNAML236 2x36W 6000 lumen 9,4 kg TNAML258 2x58W 10400 lumen 12,1 kg Dimensional sketches 66 Product code Dimensions A B TNAML218 720 738 TNAML236 1100 1118 TNAML258 1630 1648 For certificates, spare parts, light intensity diagrams, etc., please consult our website: www.ysebaert.be 3 Lighting 1 Fluorescent lamp fittings for zone 1, 2, 21 and 22 5 Surface mounting - flameproof enclosure These fluorescent lamp fittings have a flameproof enclosure (Exd) with aluminium endcaps and diffuser of polycarbonate (impact resistant). These fittings are provided with an electronic ballast and are, due to the maximum classification ExdIICT6, everywhere applicable. II 2 G Ex d IIC T6 II 2 D Ex tD A21 IP66 T85°C Zone 1 Specifications Housing Cover Reflector Protection Electronic ballast Electrical connection Voltage Lamp holder Switch Cable entry Mounting * Note Zone 2 corrosion and seawater resistant aluminium with polyurethane paint RAL6003 polycarbonate steelplate, white IP66 cos φ 0,90 2P+E (4 mm²) 220-230VAC - 50/60Hz TLD (2 pins) none, supply voltage to be shut down before opening 2 entries M20 (without glands) 2 mounting clamps screw cap attached to the housing by a chain Zone 21 Zone 22 INERIS02ATEX0039 On request • • • emergency lighting clamps for pole mounting voltages 12...230Vdc ±10 % / 12...240Vac ±10 % Ordering data Code Power Weight Ambiant temperature EVF-P-118 1x18W 6,0 kg -20°C - +50°C EVF-P-218 2x18W 8,0 kg -20°C - +50°C EVF-P-136 1x36W 6,0 kg -20°C - +50°C EVF-P-236 2x36W 9,0 kg -20°C - +50°C EVF-P-158 1x58W 8,0 kg -20°C - +50°C EVF-P-258 2x58W 10,0 kg -20°C - +50°C Dimensional sketches Product code Dimensions A B EVF-P-118 764 630 EVF-P-218 764 630 EVF-P-136 1374 1240 EVF-P-236 1374 1240 EVF-P-158 1679 1545 EVF-P-258 1679 1545 www.ysebaert.be ● info@ysebaert.be ● T +32(0)3 328 06 60 ● F +32(0)3 328 06 80 67 3 Lighting 2 Fluorescent lamp fittings for zone 2 and 22 1 nD16 series These fluorescent lamp fittings are suited for standard fluorescent lamps (2 pins) and provided with an electronic ballast. Type nD161/162 has stainless steel clamps (one has to be opened with a screwdriver) and a hinged cover. This fitting is admitted in zone 2 as well as zone 22 (dust). Zone 1 Specifications Zone 2 Housing Cover Reflector glass-fibre reinforced polyester polycarbonate resin, with prism optics glass-fibre reinforced polyester, with fixed-on components stainless steel clamps, hinged cover IP65 2P terminal block (4 mm²) 220-240VAC/DC - 0-50/60Hz II (double isolated) TLD (2 pins) 2 M20 entries (complete with 2 glands and 1 plug) with mounting in open air a breather must be used. For ambient temperatures < -5°C, lamps with ø 38 mm must be used, Locking Protection Electrical connection Voltage Isolation class Lamp holder Cable entry * Note II 3 G ExnAC IIC T4 II 3 D Ex tD A22 IP65 T80-T100°C Zone 21 Zone 22 TUV00ATEX1541 On request • • • • • • throughwiring (until max. 5x 2,5 mm²) switch will disconnect the supply voltage by opening the diffuser mirror reflector for high ambient temperature until 50°C emergency lighting breather (for mounting in open air) version for recessed mounting Ordering data Code Power Weight Ambiant temperature nD161118EVG 1x18W 2,2 kg -20°C - +40°C nD161136EVG 1x36W 2,9 kg -20°C - +40°C nD161158EVG 1x58W 4,3 kg -20°C - +40°C nD162218EVG 2x18W 2,9 kg -20°C - +40°C nD162236EVG 2x36W 5,1 kg -20°C - +40°C nD162258EVG 2x58W 6,3 kg -20°C - +40°C Dimensional sketches 68 Product code Dimensions A B C nD161118EVG 662 400 110 nD161136EVG 1272 800 110 nD161158EVG 1572 1000 110 nD162218EVG 662 550 197 nD162236EVG 1272 800 197 nD162258EVG 1572 1000 197 For certificates, spare parts, light intensity diagrams, etc., please consult our website: www.ysebaert.be 3 Lighting 3 Emergency lighting for zone 1, 2, 21 and 22 1 Surface mounting - polyester enclosure These emergency lighting fittings are suited for standard fluorescent lamps (2 pins) and provided with an electronic ballast. The maintenance-free NiCd battery guarantees an emergency autonomy of 1 to 3 hours (see ordering data) with 1 lamp and is mounted in a separate enclosure on top of the fitting. The electronic emergency power unit is provided with a safety against deep discharge and a LED, indicating the proper functioning of the charger. II 2 G Ex d e q IIC T4 II 2 D Ex tD A21 IP66 T80°C Zone 1 Zone 2 Zone 21 Zone 22 PTB05ATEX2066 Specifications Housing Cover Reflector Protection Electronic ballast Electrical connection Voltage Battery Autonomy Lamp holder Switch Cable entry Ambiant temperature Mounting glass-fibre reinforced polyester polycarbonate resin, with prism optics glass-fibre reinforced polyester, white, hinged IP66 Exeq, cos φ 0,95 L1+L1’+N+PE, 6 mm² max. 220-254VAC - 50/60Hz Exe, NiCd 6V, 4Ah or 7Ah 1 or 3 hours TLD (2 pins) Exd 2 M25 entries (complete with 2 glands and 1 plug), suited for feed-through -20°C - +55°C by means of 2 threaded bushes M8 for: - ceiling/wall mounting - chain mounting On request • • throughwiring (2 terminal blocks) three-phase connection Ordering data Code Power Emergency service Autonomy Weight e14822/1/4 2x18W 1x18W 1 hour 8,9 kg e14842/1/4 2x36W 1x36W 1 hour 8,9 kg e14822/3/7 2x18W 1x18W 3 hours 9,3 kg e14842/3/7 2x36W 1x36W 3 hours 12,7 kg Dimensional sketches Product code Dimensions A B e14822/1/4 600 913 e14842/1/4 800 1523 e14822/3/7 600 913 e14842/3/7 800 1523 www.ysebaert.be ● info@ysebaert.be ● T +32(0)3 328 06 60 ● F +32(0)3 328 06 80 69 3 Lighting 3 Emergency lighting for zone 1, 2, 21 and 22 2 Surface mounting - flameproof enclosure These fluorescent lamp fittings have a flameproof enclosure (Exd) with aluminium endcaps and diffuser of polycarbonate (impact resistant). These fittings are provided with an electronic ballast and are, due to the maximum classification ExdIICT6, everywhere applicable. The NiCd battery guarantees in emergency function an autonomy of 1 to 1h30 hour. Available in permanent and non-permanent execution. II 2 G Ex d IIC T6 II 2 D Ex tD A21 IP66 T85°C Zone 1 Zone 2 Zone 21 Zone 22 INERIS02ATEX0039 Specifications Housing Cover Reflector Protection Electronic ballast Electrical connection Voltage Battery Autonomy Lamp holder Switch Cable entry Ambiant temperature Mounting corrosion and seawater resistant aluminium with polyurethane paint RAL6003 polycarbonate steelplate, white IP66 cos φ 0,95 4 mm² 230VAC - 50/60Hz NiCd 3,6V 4Ah 1 hour TLD (2 pins) none, supply voltage to be shut down before opening 2 entries M20 (without glands) -20°C - +50°C 2 mounting clamps On request • • clamps for pole mounting tension 240VAC Ordering data Code Normal service EVF-P-118-LE-NP EVF-P-118-LE-P 1x18W EVF-P-136-LE-NP EVF-P-136-LE-P 1x36W EVF-P-158-LE-NP Emergency service Autonomy Weight 1x18W 1 hour 7,7 kg 1x18W 1 hour 8,0 kg 1x36W 1 hour 9,7 kg 1x36W 1 hour 10,0 kg 1x58W 1 hour 10,7 kg EVF-P-158-LE-P 1x58W 1x58W 1 hour 11,0 kg EVF-P-218-LE-P 2x18W 1x18W 1 hour 8,0 kg EVF-P-236-LE-P 2x36W 1x36W 1 hour 10,0 kg EVF-P-258-LE-P 2x58W 1x58W 1 hour 11,0 kg Dimensional sketches 70 Product code Dimensions A B EVF-P-118-LE-P 764 630 EVF-P-218-LE-P 764 630 EVF-P-136-LE-P 1374 1240 EVF-P-236-LE-P 1374 1240 EVF-P-158-LE-P 1679 1545 EVF-P-258-LE-P 1679 1545 EVF-P-118-LE-NP 764 630 EVF-P-136-LE-NP 1374 1240 EVF-P-158-LE-NP 1680 1545 For certificates, spare parts, light intensity diagrams, etc., please consult our website: www.ysebaert.be 3 Lighting 4 Emergency lighting for zone 2 and 22 1 nD16 series These fluorescent lamp fittings are suited for standard fluorescent lamps (2 pins) and provided with an electronic ballast. The maintenance-free NiCd battery guarantees in emergency situation an autonomy of 1 to 3 hours (see ordering data). This fitting is admitted in zone 2 (gas) as well as zone 22 (dust). Zone 1 Specifications Zone 2 Housing Cover Reflector Protection Electronic ballast Electrical connection Voltage Battery Autonomy Lamp holder Switch Cable entry Ambiant temperature Mounting glass-fibre reinforced polyester polycarbonate resin, with prism optics glass-fibre reinforced polyester, white, hinged IP65 electronic connector L1+L’+N+E, 2,5 mm² max. 230V - 50/60 Hz Exe, NiCd 6V, 4Ah or 7Ah 1 or 3 hours TLD (2 pins) none, supply voltage to be shut down before opening 2 entries M20 (complete with 2 glands and 1 plug) 0°C - +30°C 0°C - +40°C (nD162 1...) 2 mounting holes II 3 G Ex nAC IIC T4 II 3 D Ex tD A22 IP65 T80°C Zone 21 Zone 22 TUV00ATEX1541 On request • throughwiring (5x 2,5 mm²) Ordering data Code Power Light power factor (%) Autonomy Weight nD161136/22/1EVG 1x36W 22 1 hour 3,6 kg nD161158/17/1EVG 1x58W 17 1 hour 4,1 kg nD162118/35/1EVG 1x18W 35 1 hour 3,6 kg nD162136/22/1EVG 1x36W 22 1 hour 5,5 kg nD162158/17/1EVG 1x58W 17 1 hour 6,3 kg nD162218/35/1EVG 2x18W 35 1 hour 3,6 kg nD162236/22/1EVG 2x36W 22 1 hour 5,3 kg nD162258/17/1EVG 2x58W 17 1 hour 6,3 kg nD161136/10/3EVG 1x36W 10 3 hours 3,9 kg nD162118/20/3EVG 1x18W 20 3 hours 3,9 kg nD162136/10/3EVG 1x36W 10 3 hours 5,6 kg nD162218/20/3EVG 2x18W 20 3 hours 3,6 kg nD162236/10/3EVG 2x36W 10 3 hours 5,6 kg Dimensional sketches Product code Dimensions A B C nD161136/22/1EVG 1272 800 110 nD161158/17/1EVG 1575 1100 110 nD162118/35/1EVG 662 550 197 nD162136/22/1EVG 1272 800 197 nD162158/17/1EVG 1575 1100 197 nD162218/35/1EVG 662 550 197 nD162236/22/1EVG 1272 800 197 nD162258/17/1EVG 1575 1100 197 nD161136/10/3EVG 1272 800 110 nD162118/20/3EVG 662 550 197 nD162136/10/3EVG 1272 800 197 nD162218/20/3EVG 662 550 197 nD162236/10/3EVG 1272 800 197 www.ysebaert.be ● info@ysebaert.be ● T +32(0)3 328 06 60 ● F +32(0)3 328 06 80 71 3 Lighting 5 Induction lightingQL85, ENDURA 1 Endura 150W Induction lighting is characterised by a very long life (at least 60,000 hours), a direct ignition, flicker-free operation, insensitivity to temperature fluctuations and is suited for DC voltage. With its very long life this lighting can be used in hard-to-reach places and places where light is absolutely needed (no lamps need to be replaced for at least 7 years of continuous use). II 2 G Ex d e IIC T4 Zone 1 Zone 2 Zone 21 Zone 22 PTB99ATEX2065 Specifications Housing Cover Reflector Protection Electrical connection Voltage Cable entry Mounting Specifications lamp Life Light intensity Colour reproduction Colour temperature galvanised steel, painted RAL7035 (grey) safety glass (impact-resistant), hinged mirror reflector made of anodised aluminium IP65 L+N+PE 2,5mm² 220-240VAC/DC -10% +6%, 0/50-60Hz 1 gland and 1 EExe M25 plug mounting brackets on the side of the fitting On request 60.000 hours 12.000 lumen Ra 80 (very good) 4.000 K • other mounting possibilities Ordering data Code Power Weight Ambiant temperature e2070/150 150W 12 kg -30°C - +40°C Dimensional sketches 72 For certificates, spare parts, light intensity diagrams, etc., please consult our website: www.ysebaert.be 3 Lighting 5 Induction lightingQL85, ENDURA 2 QL85/165W Induction lighting is characterised by a very long life (at least 60,000 hours), a direct ignition, flicker-free operation, insensitivity to temperature fluctuations and is suited for DC voltage. With its very long life this lighting can be used in hard-to-reach places and places where light is absolutely needed (no lamps need to be replaced for at least 7 years of continuous use). II 2 G Ex d e IIC T6 Zone 1 Zone 2 Zone 21 Zone 22 PTB98ATEX1122 Specifications Housing Cover Protection Electrical connection Voltage Cable entry Mounting Specifications lamp Life Light intensity aluminium with powder coating, RAL7035 (grey) safety glass fluctuation of temperature resistant IP66/67 L+N+PE 6 mm² 220-240VAC/DC, 0/50-60Hz 1x M25 with gland see mounting accessories 60.000 hours 85W - 6.000 lumen 165W - 12.000 lumen On request • • • several cable entries protection cast guard reflector Ordering data Code Power Weight Ambiant temperature d6300/085QLEVG 85W 14,5 kg -20°C - +40°C d6300/165QLEVG 165W 14,5 kg -20°C - +40°C Dimensional sketches www.ysebaert.be ● info@ysebaert.be ● T +32(0)3 328 06 60 ● F +32(0)3 328 06 80 73 3 Lighting 6 Autonomous safety lighting for zone 1, 2, 21 and 22 1 8860 series Testing autonomous safety lighting in hazardous areas requires special procedures and is very labour-intensive. A safety lighting with active self-test function greatly enhances the safety. The fitting tests its emergency function itself at regular intervals, while the lamp and battery are permanently checked. Every six months the battery is completely discharged and recharged, whereby the battery’s capacity is checked: this also increases the battery’s life. Errors are clearly signalled by means of 3 red LEDs (lamp - battery electronics). The user can quickly determine whether the error itself can be corrected (lamp, battery) or whether the electronics need to be repaired by the manufacturer. Its active self-test function allows significant savings on testing costs and unnecessary replacements. It is available in a permanent and non-permanent version and with an autonomy of 1 to 3 hours. Specifications Housing II 2 G Ex d IIC T6 II 2 D Ex tD A21 IP66/67 T80°C Zone 1 Zone 2 Zone 21 Zone 22 LCIE97ATEX6012 On request • • • pictograms variant voltages potential-free make-and-break contacts for external signalling borosilicate glass with aluminium ends, painted RAL7038 O-ring IP66/67 230V - 50Hz in- and external earthing bolts 1 or 3 hours standard 2 M20x1.5 entries without glands with 2 suspension brackets Seal Protection Voltage Earthing Autonomy Self-test function Cable entry Mounting Ordering data Code Lamp Autonomy Voltage Weight 8860-EX-A-1-ZT 2xTL 8W 1 hour 230V-50Hz 7.5 kg 8860-EX-A-3-ZT 2xTL 8W 3 hours 230V-50Hz 7.5 kg 8860-EX-B-1-ZT 1xTL 8W 1 hour 230V-50Hz 7.0 kg 8860-EX-B-3-ZT 1xTL 8W 3 hours 230V-50Hz 7.0 kg Dimensional sketches 74 For certificates, spare parts, light intensity diagrams, etc., please consult our website: www.ysebaert.be 3 Lighting 7 Floodlights for zone 1, 2, 21 en 22 1 FL series - IIB+H2 The FL floodlights with built-in ballast are available for halogen and discharge lamps. The integrated gasket in the flange guarantees a water-tightness of IP65. The use of stainless steel for the mounting bracket and bolts makes the floodlight suited for very aggressive environments. Zone 1 Specifications Zone 2 Housing Cover bolts Seal Protection Lamp Lamp holder Reflector Electrical connection Condensator Earthing Ambiant temperature Mounting bracket corrosion- and saltwaterproof aluminium with polyurethane paint (anti-condenstion paint inside) stainless steel, loss-free special fixed cover seal (integrated in the flange) IP65 included (mounted) E40 aluminium, polished Exe connection box with 4 terminals 4 mm² (through-wiring) standard for cos φ 0,90 in- and external M6 earthing bolt -20°C - +40°C stainless steel, adjustable II 2 G Ex d e IIB+H2 T3 II 2 D Ex tD A21 IP65 T200°C Zone 21 Zone 22 INERIS00ATEX0023X On request • • • • version in stainless steel horizontal anti-blinding grid vertical anti-blinding grid ambiant temperature -30°C - +50°C Ordering data Code Power Lamp Voltage Weight FL-50-HA-V-L 500W halogen 220V 19 kg FL-2x70-HA-V-L 2X70W halogen 24V 20 kg FL-25-IM-V-C-L 250W metal iodide 230V-50 Hz 22 kg FL-40-IM-V-C-L 400W metal iodide 230V-50 Hz 23 kg FL-25-SA-V-C-L 250W high-press. sodium 230V-50 Hz 22 kg FL-40-SA-V-C-L 400W high-press. sodium 230V-50Hz 23 kg Dimensional sketches www.ysebaert.be ● info@ysebaert.be ● T +32(0)3 328 06 60 ● F +32(0)3 328 06 80 75 3 Lighting 7 Floodlights for zone 1, 2, 21 en 22 2 d3000 / d4000 series - IIC Floodlights d3000 and d4000 with built-in ballast are available for halogen and discharge lamps. In case of need, a capacitor box can be mounted on the back side of the floodlight. Mounting and replacing of a lamp can be done by opening the screwcover on the side of it what makes this floodlight suitable for gas group IIC. Extreme protection class of IP67. Specifications II 2 G Ex d e IIC T2-T3-T4 II 2 D Ex tD A21 IP67 T100-T270°C Zone 1 Zone 2 Zone 21 Zone 22 PTB04ATEX1023 PTB03ATEX1164 Housing Cover bolts Reflector Protection Electrical connection Voltage Lamp holder Cable entry Ambiant temperature Mounting bracket weather-resistant aluminium stainless steel aluminium, anodized IP67 Exe-connection box with terminals 4 mm² L1 + N + PE 220-240VAC - 50/60Hz E40 1 gland and 1 plug M25 (plastic) -20°C - +40°C steel, adjustable On request • • • capacitor ambient temperature 55°C voltage 120VAC Ordering data Code Power Lamp Temp. class Max. surface temp. d3000/125 125W high pressure mercury vapour T4 120°C Weight 24,2 kg d3000/150HI 150W halogen metal vapour T4 120°C 25,0 kg d3000/150HS 150W high pressure sodium vapour T4 130°C 25,0 kg d3000/250QT 250W halogen T3 170°C 23,0 kg d3000/250 250W high pressure mercury vapour T3 150°C 25,0 kg d3000/250HI 250W halogen metal vapour T3 160°C 25,0 kg d3000/250HS 250W high pressure sodium vapour T3 160°C 25,0 kg d3000/500QT 500W halogen T2 240°C 23,0 kg d4000/250 250W high pressure mercury vapour T4 140°C 33,0 kg d4000/250HI 250W metal vapour T4 140°C 33,0 kg d4000/250HS 250W high pressure sodium vapour T4 140°C 33,0 kg d4000/400HI 400W metal vapour T3 200°C 33,5 kg d4000/400HS 400W high pressure sodium vapour T3 200°C 33,5 kg d4000/500QT 500W halogen T3 200°C 29,5 kg d4000/600HS 600W high pressure sodium vapour T3 200°C 38,5 kg d4000/1000QT 1000W halogen T2 270°C 29,5 kg Dimensional sketches d3000 76 d4000 For certificates, spare parts, light intensity diagrams, etc., please consult our website: www.ysebaert.be 3 Lighting 8 Floodlights for zone 2 and 22 1 nD27 series The nD2770 / nD2780 floodlights with built-in ballast are available for halogen and discharge lamps. They are permitted in zone 2 (gas) aswell as zone 22 (dust). II 3 G Ex nR II T3/T4 II 3 D Ex tD A22 IP66/67 T130-T200°C Specifications Housing Cover bolts Reflector Protection Electrical connection Voltage Cable entry Mounting bracket Zone 1 weather-resistant aluminium, RAL9005 stainless steel aluminium, polished IP66 / 67 connection box with terminals L1+N+PE 2,5 mm² 220-240VAC - 50/60Hz 1 gland and 1 plug M20 aluminium, adjustable Zone 2 Zone 21 Zone 22 TUV00ATEX1653 On request • • screw clamps 6 mm² (only for nD2780) special coating (offshore application) Ordering data Code Power Lamp Lamp holder Temp. class Max. surface temp. Ambiant temperature Weight nD2770-100-E27 100W halogen E27 T3 160°C -30°C - +50°C 3,4 kg nD2770-150-E27 150W halogen E27 T3 180°C -30°C - +50°C 3,4 kg nD2770-080-HGL 80W high pressure mercury vapour E27 T3 170°C -30°C - +50°C 4,5 kg nD2770-125-HGL 125W high pressure mercury vapour E27 T3 200°C -30°C - +40°C 4,5 kg nD2770-070-HS 70W high pressure sodium E27 T3 150°C -30°C - +50°C 4,5 kg nD2770-110-HS 110W high pressure sodium E27 T3 180°C -30°C - +40°C 4,5 kg nD2780-250-E27 250W halogen E27 T3 150°C -30°C - +50°C 8,0 kg nD2780-500-E40 500W halogen E40 T3 190°C -30°C - +40°C 8,0 kg nD2780-150-HS 150W high pressure sodium E40 T4 130°C -30°C - +50°C 9,4 kg nD2780-250-HS 250W high pressure sodium E40 T3 170°C -30°C - +50°C 10,8 kg nD2780-400-HS 400W high pressure sodium E40 T3 190°C -30°C - +40°C 13,3 kg nD2780-250-HGI 250W mercury vapour E40 T3 170°C -30°C - +40°C 10,8 kg nD2780-400-HGI 400W mercury vapour E40 T3 190°C -30°C - +40°C 13,3 kg Dimensional sketches nD2770, nD2780, www.ysebaert.be ● info@ysebaert.be ● T +32(0)3 328 06 60 ● F +32(0)3 328 06 80 77 3 Lighting 9 Autonomous hand lamps 1 Type HS4EX The HS4EX is a multifunctional hand lamp with emergency lighting and flashlight functions. Especially suited as inspection lamp and signalling lamp. Specific characteristics are: - 6 hours of halogen light - on/off switch - adjustable handle - weighs only 950 g - belt clip - capacity indicator - automatic charger 230VAC-12/24VDC - maintenance-free gel battery (no memory effect) - emergency function in case of mains loss - automatic switch-over from primary lamp to secondary lamp in case of malfunctioning primary lamp and excessive battery discharge - flashlight function II 2 G EExe ib IIC T4 Zone 1 Zone 2 Zone 21 Zone 22 TUV07ATEX553783X Specifications Housing Battery Dimensions Weight Ambiant temperature Specifications Charger Supply voltage impact-resistant plastic maintenance-free gel battery 4V/3,5Ah 104x245x72mm (LxHxP) 0,950 kg -20°C - +50°C 230 VAC 12 or 24VDC Mounting wall mounting Charger dimensions 114x123x64mm Charger weight 0,5 kg Delivery, Set consisting of Delivery content hand-held floodlight charger connection cables 230V and 12/24V 2 ancillary lenses (clear and yellow) Ordering data Code Primary lamp Secondary lamp Autonomy HS4EX halogen 4,0V/2W light bulb 3,7V/1,1W 6 hours Dimensional sketches 78 For certificates, spare parts, light intensity diagrams, etc., please consult our website: www.ysebaert.be 3 Lighting 9 Autonomous hand lamps 2 Type KS-8650 The KS-8650 is a small and lightweight LED hand lamp with 3 steps. The autonomy depends on the used light intensity, and differs between 10 and 27 hours. The belt clip and included wristband facilitate the fixing. Specifications Housing Protection Battery Weight Ambiant temperature Delivery content impact-resistant plastic IP67 lithium battery 3,2V/3Ah 0,160 kg -20°C - +60°C handlamp charger wristband II 2 G Ex ia IIC T4 Zone 1 Zone 2 Zone 21 Zone 22 IBEXU08ATEX1118 On request • green or yellow housing Ordering data Code Lamp Power Autonomy Temperature class KS-8650 LED 3000 / 2000 / 1000 lux 10 / 14 / 27 hours T4 Dimensional sketches www.ysebaert.be ● info@ysebaert.be ● T +32(0)3 328 06 60 ● F +32(0)3 328 06 80 79 3 Lighting 10 Portable lamps and floodlights 1 KHLE 70EN - 12/24/42V series for zone 1 and 2 The KHLE 70EN portable lamps are fitted with a halogen lamp of 12, 24 or 42V, providing a powerful beam of light. The lamp is used during inspections, maintenance and cleaning of boilers, silos, etc. The standard version includes a lamp, carrying strap, on/off switch, trumpet gland and a rubber protection against shocks. A cable with plug is available on request. II 2 G EEx de IIC T3/T4 Zone 1 Zone 2 Zone 21 Zone 22 BVS03ATEXE279 Specifications Housing light metal, handle made of impact-resistant plastic, rubber protection IP54 halogen H3 - leather carrying strap - on/off switch - trumpet gland Protection Lamp Lamp holder Features Ordering data Code Power Voltage Temperature class Weight KHLE70EN12/55 55W 12V T4 2,5kg KHLE70EN24/70 70W 24V T3 2,5kg KHLE70EN42/65 65W 42V T3 2,5kg Dimensional sketches 80 For certificates, spare parts, light intensity diagrams, etc., please consult our website: www.ysebaert.be 3 Lighting 10 Portable lamps and floodlights 2 Portable lamps - 24V/230V for zone 1, 2, 21 and 22 The e8310 lamps are suited for incandescent lamps up to 60W and voltages of 24-42V AC/DC and 220-230V AC/DC. The standard version is fitted with a handle, rubber protection rings and a galvanised protective guard. A cable with plug can be mounted on request. Zone 1 Specifications Zone 2 Housing Protection Lamp Lamp holder Isolation class Ambiant temperature II 2 G Ex e II T3-T4 II 2 D Ex tD A21 IP65 T145°C handle and protection rings made of rubber, guard of galvanised steel IP65 incandescent lamp (not included) E27 II (double insulation) -20°C - +40°C Zone 21 Zone 22 PTB01ATEX2144 Ordering data Code Power Voltage Temperature class Weight e8310ATEX 25W 220-230V T4 2,3kg e8310ATEX 40W 220-230V T4 2,3kg e8310ATEX 60W 220-230V T4 2,3kg e8310ATEX 25W 24-42V T3 2,3kg e8310ATEX 40W 24-42V T3 2,3kg e8310ATEX 60W 24-42V T3 2,3kg Dimensional sketches www.ysebaert.be ● info@ysebaert.be ● T +32(0)3 328 06 60 ● F +32(0)3 328 06 80 81 3 Lighting 10 Portable lamps and floodlights 3 Portable floodlight for zone 1, 2, 21 and 22 The portable floodlight is extremely suitable as temperary (additional) lighting during maintenance activities. II 2 G Ex d IIC T3/T4 II 2 D Ex tD A21 IP66 T142°C/T120°C Specifications Housing Seal Protection Electrical connection Voltage Earthing Lamp Lamp holder Cable entry Ambiant temperature Mounting bracket aluminium (grey painted) O-ring IP66 2 x 2 x 2,5 mm² 12-24V AC/DC internal and external earthing bolt halogen H3 M20 -40°C - +55°C adjustable Zone 1 Zone 2 Zone 21 Zone 22 LCIE02ATEX6227 On request • • built-in transformer for power supply 230V and 110V ambient temperature up to +55°C Ordering data Code Power Voltage Temperature class Weight LG-95149 55W 12VAC/DC T4 8 kg LG-95150 70W 24VAC/DC T4 8 kg Dimensional sketches 82 For certificates, spare parts, light intensity diagrams, etc., please consult our website: www.ysebaert.be 3 Lighting 10 Portable lamps and floodlights 4 Portable worklight for zone 1 The Slam Hornet 3x40W Ex Worklight allows you to have a high, 180° spread, light output at a low power consumption. The unit withstands thermal and mechanical shocks and is suitable for use in the most harsh environments. This fixture can stand on the ground in a number of different positions or can be attached to scaffolding/staging as a more permanent fixture. The outer polycarbonate tube has an anti-static protective film which is replaceable, thus assuring optimum light output. The Slam Hornet 3x40W Worklight can be equipped with output sockets allowing units to be linked together. II 2 G EEx em II T3 Zone 1 Zone 2 Zone 21 Zone 22 VTT03ATEX042 Specifications Housing Protection Dimensions Ballast Electrical connection Lamp Life Light intensity Consumption Weight Ambiant temperature polycarbonate enclosure around an aluminium frame IP54 750 x 300 x 250 mm electronic 10m cable type H07RN-F 3 fluorescent tubes +/- 10.000 hours 10.500 lumen 120W 10 kg -20°C - +40°C On request • • • • • • • • carrying strap plug recessed sockets magnets for easy attachment to metal structures other type of cable other cable length metallic cable gland suply voltage 42VAC/DC or 110VAC/DC Ordering data Code Voltage Power SH340-32210Z000 24VAC/DC 3x40W SH340-63210Z000 230VAC/DC 3x40W www.ysebaert.be ● info@ysebaert.be ● T +32(0)3 328 06 60 ● F +32(0)3 328 06 80 83 3 Lighting 10 Portable lamps and floodlights 5 Portable worklight for zone 1, 2, 21 and 22 Due to its low weight and the included carrying strap, the Slam Hornet Ex Worklight is truly portable! It is extremely reliable, requires virtually no maintenance and has a high light output. The electronic components of the Slam Hornet are protected by encapsulation. All the mountings are flexible and the alloy profile give the unit immense strength. The outer polycarbonate tube has an anti-static protective film which is replaceable, thus assuring optimum light output. The Slam Hornet can be equipped with an output socket allowing units to be linked together. II 2 G Ex e mb IIC T3 Gb II 2 D Ex t IIIC T90°C Db IP66 Zone 1 Zone 2 Zone 21 Zone 22 VTT08ATEX066 Specifications Housing Protection Ballast Electrical connection Lamp Life Ambiant temperature polycarbonate enclosure around an aluminium frame IP66 electronic 5m cable type H07RN-F compact fluorescent lamp +/- 10.000 hours -20°C - +40°C On request • • • • • • plug recessed socket magnets for easy attachment to metal structures other type of cable other cable length suply voltage 42VAC/DC or 110VAC/DC Ordering data 84 Code Voltage Power Light intensity Weight SH118-12205Z000 12VAC 1x18W 1200 lumen 0,75 kg SH218-12205Z000 12VAC 2x18W 2400 lumen 1,5 kg SH118-22205Z000 12VDC 1x18W 1200 lumen 0,75 kg SH118-32205Z000 24VAC/DC 1x18W 1200 lumen 0,75 kg SH118-63205Z000 230VAC/DC 1x18W 1200 lumen 0,75 kg SH136-22205Z000 12VDC 1x36W 2900 lumen 1,65 kg SH136-32205Z000 24VAC/DC 1x36W 2900 lumen 1,65 kg SH136-63205Z000 230VAC/DC 1x36W 2900 lumen 1,65 kg SH236-32205Z000 24VAC/DC 2x36W 5800 lumen 2,70 kg SH236-63205Z000 230VAC/DC 2x36W 5800 lumen 2,70 kg SHL236-22205Z000 12VDC 2x36W 5800 lumen 3,00 kg SHL236-32205Z000 24VAC/DC 2x36W 5800 lumen 3,00 kg SHL236-63205Z000 230VAC/DC 2x36W 5800 lumen 3,00 kg For certificates, spare parts, light intensity diagrams, etc., please consult our website: www.ysebaert.be 3 Lighting 10 Portable lamps and floodlights 5 Portable worklight for zone 1, 2, 21 and 22 Dimensional sketches Product code Dimensions L Ø SH118-12205Z000 335 115 SH218-12205Z000 575 115 SH118-22205Z000 335 115 SH118-32205Z000 335 115 SH118-63205Z000 335 115 SH136-22205Z000 535 115 SH136-32205Z000 535 115 SH136-63205Z000 535 115 SH236-32205Z000 865 115 SH236-63205Z000 865 115 SHL236-22205Z000 1020 115 SHL236-32205Z000 1020 115 SHL236-63205Z000 1020 115 Code Description Picture SH-B double bracket SH-H hook SH-HC centered hook SH-HG handle SH-M magnet SH-O eye mounting Mounting accessories www.ysebaert.be ● info@ysebaert.be ● T +32(0)3 328 06 60 ● F +32(0)3 328 06 80 85 3 Lighting 10 Portable lamps and floodlights 6 Inspection lighting for zone 1, 2, 21 and 22 The Slam Hornet 3x3W LED is designed and certified to the latest standards and is suitable for use in zone 1, 2, 21 and 22. Its limited size and low weight make this lamp ideal for use in narrow spaces II 2 G Ex e mb op is IIC T4 Gb II 2 D Ex t IIIC IP66 T75°C Db Zone 1 Zone 2 Specifications Housing Protection Lamp Electrical connection Life Weight Ambiant temperature polycarbonate IP66 high intensity LED 5m cable +/- 50.000 hours 0,65 kg -20°C - +40°C Zone 21 Zone 22 VTT09ATEX001 On request • version for zone 0 Ordering data Code Voltage Power SH3x3LED-24-IIC 24VAC/DC 3x3W SH3x3LED-42-IIC 42VAC/DC 3x3W SH3x3LED-110-IIC 110VAC/DC 3x3W SH3x3LED-230-IIC 230VAC 3x3W Dimensional sketches 86 For certificates, spare parts, light intensity diagrams, etc., please consult our website: www.ysebaert.be 3 Lighting 11 Suspension fittings 1 EVde series The suspension fittings of the EV series are available for discharge lamps. The ballast and starter are built in, making a separate enclosure superfluous. The Exe connection box and the mounting bracket grant a quick installation. A variety of options are available, including protective guard, reflector, refractor, etc. Specifications II 2 G Ex d e IIC T3/T4/T5 II 2 D Ex tD A21 IP65 T200°C/T135°C/T100°C Zone 1 Zone 2 Zone 21 Zone 22 INERIS01ATEX0019X Housing Protection Electronic ballast Electrical connection Cable entry Ambiant temperature Mounting corrosion- and saltwaterresistant aluminium with polyurethane painting RAL6003 IP65 standard for cos φ 0,90 Exe connection box with 4 terminals of 4mm² + earthing clamp 2 entries M25 -30°C - +40°C with adjustable stainless steel bracket On request • ambient temperature -40°C - +60°C Ordering data Code Power Lamp Temperature class Max. surface temp. Weight EVde2-HG050-VCL 50W mercury discharge lamp T4 135°C 5,4 kg EVde2-HG080-VCL 80W mercury discharge lamp T4 135°C 5,5 kg EVde3-HG125-VCL 125W mercury discharge lamp T3 200°C 7,4 kg EVde4-HG250-VCL 250W mercury discharge lamp T3 200°C 14,8 kg EVde5-HG400-VCL 400W mercury discharge lamp T3 200°C 17,8 kg EVde2-NA070-VCL 70W high-pressure sodium T4 135°C 6,0 kg EVde4-NA100-VCL 100W high-pressure sodium T3 200°C 7,6 kg EVde4-NA150-VCL 150W high-pressure sodium T3 200°C 8,4 kg EVde4-NA250-VCL 250W high-pressure sodium T3 200°C 15,0 kg EVde5-NA400-VCL 400W high-pressure sodium T3 200°C 18,0 kg EVde4-IM250-VCL 250W metal iodide T3 200°C 15,0 kg EVde5-IM400-VCL 400W metal iodide T3 200°C 18,0 kg www.ysebaert.be ● info@ysebaert.be ● T +32(0)3 328 06 60 ● F +32(0)3 328 06 80 87 3 Lighting 11 Suspension fittings 1 EVde series Dimensional sketches EVde2 - 4 88 EVde5 Product code Dimensions A B C D EVde2-HG050-VCL 163 467 680 160 EVde2-HG080-VCL 163 467 680 160 EVde3-HG125-VCL 195 472 686 160 EVde4-HG250-VCL 220 535 748 160 EVde5-HG400-VCL 281 758 972 160 EVde2-NA070-VCL 163 467 680 160 EVde4-NA100-VCL 220 535 748 160 EVde4-NA150-VCL 220 535 748 160 EVde4-NA250-VCL 220 535 748 160 EVde5-NA400-VCL 281 758 972 160 EVde4-IM250-VCL 220 535 748 160 EVde5-IM400-VCL 281 758 972 160 For certificates, spare parts, light intensity diagrams, etc., please consult our website: www.ysebaert.be 3 Lighting 12 Tank inspection lighting 1 USL06 series The compact USL tank inspection lighting is especially designed to illuminate the interior of boilers, tanks, reactors, etc. and fits on all common II 2 G EExde IIC T3/T4 II 2 D IP67 T195°C/T130°C sight glass fittings. Specifications Housing Seal Protection Lamp Earthing Cable entry Ambiant temperature Mounting Sight glass fittings corrosion-resistant aluminium alloy G-Al Si 12 Mg O-ring (VITON) IP67 halogen lamp in- and exterior earthing bolt Exe connection box with M20 trumpet gland -20°C - +40°C by means of 1 included central hinged bracket made of stainless steel (M8 fastener) the fittings fit on sight glass fittings from size DN50 Zone 1 Zone 2 Zone 21 Zone 22 PTB99ATEX1157 (zone 1+2) BVS06ATEXE009 (zone 21+22) On request • built-in timer (switch-on time 5 min.) Ordering data Code Halogen lamp Supply voltage Lamp holder Transformer Timer (5 min) Temp. class Weight USL06EX01220 12V-20W 12V GY6.35 T4 1.8 kg USL06EX01220T 12V-20W 12V GY6.35 T4 1.8 kg USL06EX02420 24V-20W 24V G4 T4 1.8 kg USL06EX02420T 24V-20W 24V G4 T4 1.8 kg USL06EX23020 12V-20W 230V GY6.35 T4 2.4 kg USL06EX23020T 12V-20W 230V GY6.35 T4 2.4 kg USL06EX01235 12V-35W 12V GY6.35 T4 1.8 kg USL06EX01235T 12V-35W 12V GY6.35 T4 1.8 kg USL06EX01250 12V-50W 12V GY6.35 T3 1.8 kg USL06EX01250T 12V-50W 12V GY6.35 T3 1.8 kg USL06EX02450 24V-50W 24V GY6.35 T3 1.8 kg USL06EX02450T 24V-50W 24V GY6.35 T3 1.8 kg USL06EX23050 230V-50W 230V GZ10 T4 1.8 kg USL06EX23050T 230V-50W 230V GZ10 T4 1.8 kg Dimensional sketches www.ysebaert.be ● info@ysebaert.be ● T +32(0)3 328 06 60 ● F +32(0)3 328 06 80 89 3 Lighting 12 Tank inspection lighting 2 USL07 series The compact USL tank inspection lighting is especially designed to illuminate the interior of boilers, tanks, reactors, etc. and fits on all common II 2 G EExde IIC T3/T4 II 2D IP67 T195°C/T130°C/T120°C/T80°C sight glass fittings. Specifications Housing Seal Protection Lamp Earthing Cable entry Ambiant temperature Mounting Sight glass fittings corrosion-resistant aluminium alloy G-Al Si 12 Mg O-ring (VITON) IP65 halogen lamp in- and exterior earthing bolt Exe connection box with M20 trumpet gland -20°C - +40°C by means of 2 included hinged brackets made of stainless steel (M8 fastener) the fittings fit on sight glass fittings from size DN50 Zone 1 Zone 2 Zone 21 Zone 22 PTB01ATEX1031 (zone 1+2) DMT01ATEXE144 (zone 21+22) On request • • built-in timer (switch-on time 5 min.) temperature class T6 Ordering data Code Halogen lamp Supply voltage Lamp holder Transformer Timer (5 min) Temp. class Weight USL07EX01250 12V-50W 12V GY6.35 T4 2.5 kg USL07EX01250T 12V-50W 12V GY6.35 T4 2.5 kg USL07EX02450 24V-50W 24V GY6.35 T4 2.5 kg USL07EX02450T 24V-50W 24V GY6.35 T4 2.5 kg USL07EX23035 12V-35W 230V GY6.35 T4 3.5 kg USL07EX23035T 12V-35W 230V GY6.35 T4 3.5 kg USL07EX23050 12V-50W 230V GY6.35 T4 3.5 kg USL07EX23050T 12V-50W 230V GY6.35 T4 3.5 kg USL07EX23075 230V-75W 230V GZ10 T3 2.5 kg USL07EX23075T 230V-75W 230V GZ10 T3 2.5 kg USL07EX2x23050 230V-50W 230V GZ10 T4 2.5 kg USL07EX2x23050T 230V-50W 230V GZ10 T4 2.5 kg Dimensional sketches 90 For certificates, spare parts, light intensity diagrams, etc., please consult our website: www.ysebaert.be 3 Lighting 13 Back lights for level gauges 1 TNCLS series The TNCLS back lights for level gauges is mounted behind the gauge glass and makes use of the latest LED technology. The fitting can be easily installed and adapted to all common gauge glasses. The long life of the LEDs, the stainless steel enclosure and the low energy consumption guarantee a maintenance-free operation. The LEDs are also resistant to vibrations. II 2 G EExem II T4 Zone 1 Zone 2 Zone 21 Zone 22 DNV2002OSLATEX0195 Specifications Housing Protection LED colour Consumption Electrical connection Voltage Earthing Cable entry Ambiant temperature Mounting stainless steel 316L IP66 yellow ± 3VA per module 4x2,5mm² 220-254VAC - 50/60Hz M6 bolt (inside and outside) 2 x M25 entries (above and below) -20°C - +45°C brackets - 1 pair for 1 module - 2 pairs or more in case of several modules On request • • • • cable entries on the side red diodes special fastening sets for high or low temperature other voltages - 110-127VAC - 50/60Hz - max. 62VDC Ordering data Code Visual length Number of modules Weight TNCLS27-1 250 1 2,3 kg TNCLS30-1 280 1 2,5 kg TNCLS34-1 320 1 2,7 kg TNCLS36-1 340 1 2,8 kg TNCLS27-2 520 2 4,3 kg TNCLS30-2 580 2 4,6 kg TNCLS34-2 660 2 5,1 kg TNCLS36-2 700 2 5,3 kg TNCLS27-3 790 3 6,2 kg TNCLS30-3 880 3 6,7 kg TNCLS34-3 1000 3 7,3 kg TNCLS36-3 1060 3 7,5 kg TNCLS30-4 1180 4 8,5 kg Dimensional sketches Product code Dimensions A TNCLS27-1 270 TNCLS30-1 300 TNCLS34-1 340 TNCLS36-1 360 TNCLS27-2 540 TNCLS30-2 600 TNCLS34-2 680 TNCLS36-2 720 TNCLS27-3 810 TNCLS30-3 900 TNCLS34-3 1020 TNCLS36-3 1080 TNCLS30-4 1200 www.ysebaert.be ● info@ysebaert.be ● T +32(0)3 328 06 60 ● F +32(0)3 328 06 80 91 4 Signalling 1 Flashlights .................................................................................................... 95 1 TNFCDM series ................................................................................ 95 2 Rotating lights .............................................................................................. 96 1 dHR series ........................................................................................ 96 3 Signal lights .................................................................................................. 97 1 WAR EVCC-series ............................................................................ 97 2 WAR EVde-series ............................................................................. 98 4 Signal horns ................................................................................................. 99 1 dHH series ........................................................................................ 99 2 dHE series ...................................................................................... 100 5 Alarm bells ................................................................................................. 101 1 dHW series ..................................................................................... 101 6 Speakers .................................................................................................... 102 1 dHS series ...................................................................................... 102 www.ysebaert.be ● info@ysebaert.be ● T +32(0)3 328 06 60 ● F +32(0)3 328 06 80 93 4 Signalling 1 Flashlights 1 TNFCDM series The standard version of the TNFCDM flashlight is made of stainless steel. The long-life xenon lamp, combined with a high mechanical integrity and corrosion resistance, significantly reduce maintenance costs. Specifications Housing Protection Lamp Flash energy Flashfrequency Starter current Color Weight Cable entry Ambiant temperature Mounting stainless steel 316L IP66 Xenon discharge lamp 5 joules 1Hz 1A red, green, yellow, clear or blue 2,5 kg M25 (without gland) -50°C - +60°C by means of a bracket II 2 G EExd IIC T4 II 2 D T127°C Zone 1 Zone 2 Zone 21 Zone 22 NEMKO01ATEX430 On request • T5 Ordering data Code Color Voltage Nominal current TNFCDM-060DC-R red 12-60 VDC 380-200mA TNFCDM-060DC-G green 12-60 VDC 380-200mA TNFCDM-060DC-Y yellow 12-60 VDC 380-200mA TNFCDM-060DC-C clear 12-60 VDC 380-200mA TNFCDM-060DC-B blue 12-60 VDC 380-200mA TNFCDM-110AC-R red 110-127VAC ± 20% - 50/60Hz 100mA TNFCDM-110AC-G green 110-127VAC ± 20% - 50/60Hz 100mA TNFCDM-110AC-Y yellow 110-127VAC ± 20% - 50/60Hz 100mA TNFCDM-110AC-C clear 110-127VAC ± 20% - 50/60Hz 100mA TNFCDM-110AC-B blue 110-127VAC ± 20% - 50/60Hz 100mA TNFCDM-230AC-R red 220-254VAC (190-272V) - 50/60Hz 100mA TNFCDM-230AC-G green 220-254VAC (190-272V) - 50/60Hz 100mA TNFCDM-230AC-Y yellow 220-254VAC (190-272V) - 50/60Hz 100mA TNFCDM-230AC-C clear 220-254VAC (190-272V) - 50/60Hz 100mA TNFCDM-230AC-B blue 220-254VAC (190-272V) - 50/60Hz 100mA Dimensional sketches www.ysebaert.be ● info@ysebaert.be ● T +32(0)3 328 06 60 ● F +32(0)3 328 06 80 95 4 Signalling 2 Rotating lights 1 dHR series The dHR rotating lights are robust and have a very high intensity due to the halogen lamp used. II 2 G Ex d e IIC T5 II 2 D Ex tD A21 IP66 T95°C Specifications Housing Lens Protection Lamp Frequency Color Terminal Weight Cable entry Ambiant temperature Mounting glass-fibre reinforced polyester polycarbonate IP66 20W halogen 60/min red, blue, yellow, green 1,5 mm2 3,5 kg 2 x M20 (1 gland, 1 plug, plastic) -20°C - +40°C wall or ceiling mounting with bracket Zone 1 Zone 2 Zone 21 Zone 22 PTB02ATEX1098 On request • • 12VDC temperature class T6 Ordering data Code Color Voltage Nominal current dHR1-120AC-R red 110/120V 50/60Hz 0,20 A dHR1-120AC-G green 110/120V 50/60Hz 0,20 A dHR1-120AC-B blue 110/120V 50/60Hz 0,20 A dHR1-120AC-Y yellow 110/120V 50/60Hz 0,20 A dHR1-230AC-R red 230V 50/60Hz 0,10 A dHR1-230AC-G green 230V 50/60Hz 0,10 A dHR1-230AC-B blue 230V 50/60Hz 0,10 A dHR1-230AC-Y yellow 230V 50/60Hz 0,10 A dHR1-024-R red 24V AC/DC 0,90 A dHR1-024-G green 24V AC/DC 0,90 A dHR1-024-B blue 24V AC/DC 0,90 A dHR1-024-Y yellow 24V AC/DC 0,90 A Dimensional sketches 96 For certificates, spare parts, light intensity diagrams, etc., please consult our website: www.ysebaert.be 4 Signalling 3 Signal lights 1 WAR EVCC-series The EVCC-WAR series signal light is equiped with an Exd connection box. The EVde-WAR series have an Exe connection box (see next page). They are being fitted with a PL lamp of 11W. Specifications Housing Lens Protection Lamp Color Voltage Weight Cable entry Ambiant temperature Mounting aluminium with polyurethane paint, RAL6003 acrylate IP65 PL lamp of 11W with E27 lamp holder (lamp not included) red, green, orange 230VAC 3,3 kg 2 x M25 entries -30°C - +40°C with connection box II 2 G Ex d IIC T5 II 2 D Ex tD A21 IP65 T100°C Zone 1 Zone 2 Zone 21 Zone 22 INERIS01ATEX0019X Ordering data Code Lamp Color EVCC-WAR011-V-R 11W PL red EVCC-WAR011-V-G 11W PL green EVCC-WAR011-V-O 11W PL orange Dimensional sketches www.ysebaert.be ● info@ysebaert.be ● T +32(0)3 328 06 60 ● F +32(0)3 328 06 80 97 4 Signalling 3 Signal lights 2 WAR EVde-series The EVde-WAR series signal light have an Exe connection box. They are being fitted with a PL lamp of 11W. II 2 G Ex d e IIC T3/T4 II 2 D Ex tD A21 IP65 T200°C/T135°C Specifications Housing Lens Protection Lamp Color Voltage Weight Cable entry Ambiant temperature Mounting aluminium with polyurethane paint, RAL6003 metacrylate IP65 PL lamp of 11W with E27 lamp holder (lamp not included) red, green, orange 230VAC 3,3 kg 2 x M25 entries -30°C - +40°C by means of included bracket (stainless steel) Zone 1 Zone 2 Zone 21 Zone 22 INERIS01ATEX0019X Ordering data Code Lamp Color EVde-WAR011-V-R 11W PL red EVde-WAR011-V-G 11W PL green EVde-WAR011-V-O 11W PL orange Dimensional sketches 98 For certificates, spare parts, light intensity diagrams, etc., please consult our website: www.ysebaert.be 4 Signalling 4 Signal horns 1 dHH series The dHH horns are particularly powerful and suited for continuousous usage. They are also available with an optional telephone relay. Specifications Housing Protection Color Sound intensity Switch-on time Terminal Weight Cable entry Ambiant temperature Mounting glass-fibre reinforced polyester IP66 black RAL 9005 105dB(A) at 1m 100% 1,5 mm² ± 3,5 kg 2 x M20 (1 gland, 1 plug, plastic) -20°C - +70°C wall or ceiling mounting with bracket II 2 G Ex de IIC T6 II 2 D Ex tD A21 IP66 T80°C Zone 1 Zone 2 Zone 21 Zone 22 PTB01ATEX1133 On request • • • 6V - 12V - 24V - 42V - 48V - 60V AC 50Hz 120V - 240V AC 60Hz 6V - 12V - 48V - 60V - 220V DC Ordering data Code Voltage Nominal current type dHH1-110AC 110 V 50 Hz 0,15 A without telephone relay dHH1-230AC 230 V 50 Hz 0,07 A without telephone relay dHH2-024DC 24 VDC 0,30 A without telephone relay dHH2-048DC 110 VDC 0,08 A without telephone relay dHHR1-230AC 230V 50Hz 0,07 A with telephone relay Dimensional sketches www.ysebaert.be ● info@ysebaert.be ● T +32(0)3 328 06 60 ● F +32(0)3 328 06 80 99 4 Signalling 4 Signal horns 2 dHE series A variant on the loudspeaker is the signal horn made of glass-fibre reinforced polyester, with no less than 31 different tones. Depending on the signal, the horn delivers a sound intensity of up to 116 dBA. The variety of signals increases its usefulness and decreases the possibility of confusion with other signalling devices. II 2 G Ex demb IIC T6 Zone 1 Zone 2 Zone 21 Zone 22 PTB03ATEX1232 Specifications Housing Protection Color Sound intensity Switch-on time Terminal Weight Cable entry Ambiant temperature Mounting glass-fibre reinforced polyester IP66 RAL7024, loudspeaker part black max. 119 dBA, 8 levels 100% 4 x 2,5mm² ± 6 kg 2 x M20 (1 cable gland, 1 plug) -20°C - +40°C wall or ceiling mounting with bracket Ordering data Code Voltage dHE1 85 - 265V AC / 50-60Hz dHE2 21,6 - 75V DC Dimensional sketches 100 For certificates, spare parts, light intensity diagrams, etc., please consult our website: www.ysebaert.be 4 Signalling 5 Alarm bells 1 dHW series The dHW series alarm bells are particularly powerful and robust and suited for continuousous usage. They are also available with an optional telephone relay. Specifications Housing Protection Color Sound intensity Switch-on time Terminal Weight Cable entry Ambiant temperature Mounting glass-fibre reinforced polyester IP66 RAL 7024 (grey) 105dB(A) at 1m 100% 1,5 mm² 3,5 kg 2 x M20 (1 gland, 1 plug, plastic) -20°C - +40°C wall or ceiling mounting with bracket II 2 G Ex de IIC T6 II 2 D Ex tD A21 IP66 T80°C Zone 1 Zone 2 Zone 21 Zone 22 PTB01ATEX1134 On request • • • 12V - 24V - 42V - 48V - 60V AC 50Hz 120V - 240V AC 60Hz 6V - 12V - 48V - 60V - 220V DC Ordering data Code Voltage type dHW1-110AC 110 V 50 Hz without telephone relay dHW1-230AC 230 V 50 Hz without telephone relay dHW2-024DC 24 VDC without telephone relay dHW2-110DC 110 VDC without telephone relay dHWR1-230AC 230V 50 Hz with telephone relay Dimensional sketches www.ysebaert.be ● info@ysebaert.be ● T +32(0)3 328 06 60 ● F +32(0)3 328 06 80 101 4 Signalling 6 Speakers 1 dHS series A revolutionary concept for explosionproof devices are the explosionproof speakers made of glass-fibre reinforced polyester. In combination with stainless steel screws and suspension brace, this product is virtually immune to corrosion. The speakers are adjustable in 6 power versions and can be used in zones 1, 2, 21 and 22 and in all gas groups IIA, IIB and IIC. Specifications II 2 G Ex demb IIC T4 II 2 D Ex tD A21 IP66 T130°C Zone 1 Zone 2 Zone 21 Zone 22 PTB03ATEX1231 Housing Color Protection Sound intensity Frequency Power Terminal Transformer Cable entry Weight Ambiant temperature Mounting glass-fibre reinforced polyester black RAL 9005 IP66 - 107dBA with 1W at 1m - 119dBA with 25W at 1m 230Hz to 10kHz adjustable up to max. 25W 6 x 2,5mm² standard 100V 2 x M20 ± 3,5 kg -55°C - +80°C wall or ceiling mounting with bracket On request • temperature class T5 or T6 Ordering data Code Max. power dHS 25W Dimensional sketches 102 For certificates, spare parts, light intensity diagrams, etc., please consult our website: www.ysebaert.be 5 Switches, control units, sockets and plugs 1 Control units Ex d e m ................................................................................ 105 1 Fixed mounting ............................................................................... 105 2 Pendant control stations ................................................................. 107 2 Fire alarms ................................................................................................. 109 1 XAW-S series .................................................................................. 109 3 Position switches.........................................................................................110 1 XCW series ......................................................................................110 4 Sockets and plugs .......................................................................................112 1 16 A Wall sockets .............................................................................112 2 16 A Couplings .................................................................................113 3 16 A Built-in wall sockets..................................................................114 4 16 A Plugs ........................................................................................115 5 32 A Wall sockets .............................................................................116 6 32 A Couplings .................................................................................117 7 32 A Built-in wall sockets..................................................................118 8 32 A Plugs ........................................................................................119 9 63 A Wall sockets ............................................................................ 120 10 63 A Plugs ....................................................................................... 121 11 125 A Wall sockets .......................................................................... 122 12 125 A Plugs ..................................................................................... 123 5 Installation switches ................................................................................... 124 1 Installation switches 16A - 250VCA ................................................ 124 6 Work switches & safety switches ............................................................... 125 1 10 - 180A work switches ................................................................. 125 2 10 - 180A safety switches ............................................................... 127 7 Motor circuit breakers................................................................................. 129 1 Motor circuit breakers 0,1 - 25A ...................................................... 129 8 Foot switches ............................................................................................. 130 1 Foot switches .................................................................................. 130 www.ysebaert.be ● info@ysebaert.be ● T +32(0)3 328 06 60 ● F +32(0)3 328 06 80 103 5 Switches, control units, sockets and plugs 1 Control units Ex d e m 1 Fixed mounting The ASSEMBL-Y series control boxes are made of plastic. The standard boxes can hold up to 3 units. Control boxes with more than 3 units are custom-made products and must be requested. The choice of control boxes is very large, allowing a suitable solution to be found for every application. II 2 G Ex d e m IIC T6 II 2 D IP65 T85°C Zone 1 Zone 2 Specifications Zone 21 Zone 22 KEMA01ATEX2109 Protection Mounting Material Ambiant temperature IP 65 with 4 mounting holes glass-fibre reinforced polyester -20°C - +40°C On request • Ampere meter Ordering data Code Number of units Dimensions (hxwxd) (mm) Gland entry Weight AS-CP0811D-1 1 110 x 75 x 75 1 x M25 0,360 kg AS-CP0816D-2 2 160 x 75 x 75 1 x M25 0,460 kg AS-CP0823D-3 3 230 x 75 x 75 1 x M25 0,670 kg Spare parts Signalling lamps LED indication lamps life of 100,000 hours LED included Code Colour Voltage XLW5-AV013 clear 24-415VAC/DC XLW5-AV033 green 24-415VAC/DC XLW5-AV043 red 24-415VAC/DC XLW5-AV053 yellow 24-415VAC/DC XLW5-AV063 blue 24-415VAC/DC ZBW-V1 LED for clear, red, yellow or blue lamp 24-415VAC/DC ZBW-V3 LED for green lamp 24-415VAC/DC Code Colour Contact block XBW5-AP21S black 1NO XBW5-AP31S green 1NO XBW5-AP41S red 1NO XBW5-AP51S yellow 1NO XBW5-AP61S blue 1NO XBW5-AP42S red 1NC Push buttons In = 3A (240VAC) 1 contactblock included ZBW-E101 1NO ZBW-E102 1NC www.ysebaert.be ● info@ysebaert.be ● T +32(0)3 328 06 60 ● F +32(0)3 328 06 80 105 5 Switches, control units, sockets and plugs 1 Control units Ex d e m 1 Fixed mounting Switches In = 3A (240VAC) Code Description XBW5-AJ21 0-1 XBW5-AJ33 1-0-2 XBW5-AJ41 01 XBW5-AJ53 102 XBW5-AJ73 10-2 XBW5-AJ83 1-02 Code Description XBW5-AG21 0-I Schema Key switches In = 3A (240VAC) key is removable in 0 position Schema Mushroom-shaped pushbuttons In = 3A (240VAC) 1 contactblock included 106 Code Colour Contact block XBW5-AS142 red 1NC XBW5-AS542 red 1NC ZBW-E101 1NO ZBW-E102 1NC For certificates, spare parts, light intensity diagrams, etc., please consult our website: www.ysebaert.be 5 Switches, control units, sockets and plugs 1 Control units Ex d e m 2 Pendant control stations Pendant control stations are sometimes used in hazardous zones. The XAW-P series provides an effective solution. You can choose from 8 standard versions or configure your own unit. The control stations come with the necessary instructions, a cable boot and a metal suspension bracket as mechanical pull relief. II 2 GD EExed IIC T4/T6 - T85°C/T135°C Zone 1 Zone 2 Zone 21 Zone 22 INERIS03ATEX0122 Specifications Protection Material Nominal current Cable boot Ambiant temperature IP65 glass-fibre reinforced polyester 10A (thermal) for cable Ø 10 - 20mm -20°C - +40°C Ordering data Code Number of units Contact elements Functions Weight XAW-P271 2 1NO 0,94 kg XAW-P281 2 1NO+1NC 1,00 kg XAW-P471 4 1NO 1,29 kg XAW-P481 4 1NO+1NC 1,40 kg XAW-P671 6 1NO 1,65 kg XAW-P681 6 1NO+1NC 1,80 kg XAW-P871 8 1NO 2,00 kg XAW-P881 8 1NO+1NC 2,25 kg www.ysebaert.be ● info@ysebaert.be ● T +32(0)3 328 06 60 ● F +32(0)3 328 06 80 107 5 Switches, control units, sockets and plugs 1 Control units Ex d e m 2 Pendant control stations Dimensional sketches Product code Dimensions b b1 XAW-P271 409 220 XAW-P281 409 220 XAW-P471 499 310 XAW-P481 499 310 XAW-P671 589 400 XAW-P681 589 400 XAW-P871 679 490 XAW-P881 679 490 Spare parts 108 Code Description ZBW-E101 Normally open contact ZBW-E102 Normally closed contact XAW-P9411 White detachable pushbutton XAW-P9412 Black detachable pushbutton XAW-P9414 Red detachable pushbutton XAW-P960 Rubber cable boot with metal suspension brace For certificates, spare parts, light intensity diagrams, etc., please consult our website: www.ysebaert.be 5 Switches, control units, sockets and plugs 2 Fire alarms 1 XAW-S series The XAW-S fire alarms are an addition to the ASSEMBL-Y control units. The pushbutton can be manually or automatically operated after the glass has been broken. The fire alarms come complete with a hammer to break the glass. II 2 G EExed IIC T6 II 2 D IP65 T85°C Zone 1 Specifications Protection Mounting Cable entry Material housing Ambiant temperature Zone 2 IP65 with 2 or 4 mounting holes 1 gland (for a cable of 8 to 13 mm) glass-fibre reinforced polyester -25°C - +40°C Zone 21 Zone 22 INERIS03ATEX0122 Ordering data Code Contact control Contacts glass intact Weight XAW-S111 automatic after breaking of the glass 1NO 0,95 kg XAW-S121 automatic after breaking of the glass 1NC 0,95 kg XAW-S151 automatic after breaking of the glass 1NO+1NC 0,98 kg XAW-S211 manually after breaking of the glass 1NO 0,95 kg XAW-S221 manually after breaking of the glass 1NC 0,95 kg XAW-S251 manually after breaking of the glass 1NO+1NC 0,98 kg Dimensional sketches www.ysebaert.be ● info@ysebaert.be ● T +32(0)3 328 06 60 ● F +32(0)3 328 06 80 109 5 Switches, control units, sockets and plugs 3 Position switches 1 XCW series The XCW stop limit switches are compact and come with an integrated cable. They are mounted either with the body or with the control button. Specifications Protection Material Rated voltage Nominal current Connection Mechanical life Ambiant temperature IP66 aluminium, painted 500V 6A integrated 1-metre cable, 5x0,75mm² 106 operations -20°C - +60°C II 2 G EExd IIC T6 II 2 D IP66 T85°C Zone 1 Zone 2 Zone 22 Mounting Weight Zone 21 INERIS03ATEX0083 On request • longer integrated cable Ordering data 110 Code Service control Operation Contact blocks Diagram XCW-A110 metal switch cam For head motion. Speed between 0,001 en 0,05 m/s. 1NO+1NC body 0,240 kg XCW-A102 switch cam with steel roll For 30° cam motion. Speed between 0,001 en 0,1 m/s. 1NO+1NC body 0,245 kg XCW-A103 switch cam with steel roll, 90° turned For 30° cam motion. Speed between 0,001 en 0,1 m/s. 1NO+1NC body 0,245 kg XCW-A115 lever with plastic roll For 30° cam motion. Maximum speed of 1,5 m/s. 1NO+1NC body 0,245 kg XCW-F110 metal switch cam For head motion. Speed between 0,001 en 0,05 m/s. 1NO+1NC head 0,260 kg XCW-F102 switch cam with steel roll For 30° cam motion. Speed between 0,001 en 0,1 m/s. 1NO+1NC head 0,265 kg XCW-F103 switch cam with steel roll, 90° turned For 30° cam motion. Speed between 0,001 en 0,1 m/s. 1NO+1NC head 0,265 kg For certificates, spare parts, light intensity diagrams, etc., please consult our website: www.ysebaert.be 5 Switches, control units, sockets and plugs 3 Position switches 1 XCW series Dimensional sketches XCW-A110 C 0 XCW-A102 C 0 XCW-A103 XCW A103 XCW-A115 XCW A115 XCW-F110 XCW F110 XCW-F102 XCW-F103 www.ysebaert.be ● info@ysebaert.be ● T +32(0)3 328 06 60 ● F +32(0)3 328 06 80 111 5 Switches, control units, sockets and plugs 4 Sockets and plugs 1 16 A Wall sockets The sockets are fitted with an integrated interruption of the poles by a double-safety device. When the plug is pulled, there will be: - an automatic and simultaneous interruption of every phase in a first explosion-proof chamber - voltage-free separation of the pins in a second explosion-proof chamber The cover can be locked in 3 positions: - with connected plug under tension - with connected plug voltage free - without plug, cover closed For safety reasons, only the mentioned explosion-proof plugs fit in the sockets. The explosion-proof plugs do fit in normal sockets in accordance with CEE17. II 2 G Ex d e IIC T6/T5 II 2 D Ex tD A21 IP66 T68°C Zone 1 Zone 2 Zone 21 Zone 22 LCIE02ATEX6068 Specifications Connection Earthing Protection Cable entries Material Ambiant temperature 2x4mm² 3 terminals (fed-through) IP66 (with or without connected plug) 3xM20 supplied with 1 gland (6,5-14,5 mm) and 2 plugs high-quality, impact-resistant plastic -40°C - +40/55°C Ordering data Code No. of poles Nom. current Voltage Weight C16-024-2 2P 16A 24 VAC 0,56 kg C16-024-3 2P+E 16A 24 VAC 0,62 kg C16-110-3 2P+E 16A 110/130 VAC 0,61 kg C16-230-3 2P+E 16A 220/240 VAC 0,61 kg C16-230-4 3P+E 16A 220/240 VAC 1,50 kg C16-230-5 3P+N+E 16A 220/240 VAC 1,60 kg C16-400-4 3P+E 16A 380/415 VAC 1,50 kg C16-400-5 3P+N+E 16A 380/415 VAC 1,60 kg Dimensional sketches 112 Product code Dimensions A B C D C16-024-2 120 202 133 272 C16-024-3 120 202 133 272 C16-110-3 120 202 133 272 C16-230-3 120 202 133 272 C16-230-4 140 240 145 310 C16-230-5 140 240 145 310 C16-400-4 140 240 145 310 C16-400-5 140 240 145 310 For certificates, spare parts, light intensity diagrams, etc., please consult our website: www.ysebaert.be 5 Switches, control units, sockets and plugs 4 Sockets and plugs 2 16 A Couplings The couplings are fitted with an integrated interruption of the poles by a double-safety device. When the plug is pulled, there will be: - an automatic and simultaneous interruption of every phase in a first explosion-proof chamber - voltage-free separation of the pins in a second explosion-proof chamber The cover can be locked in 3 positions: - with connected plug under tension - with connected plug voltage free - without plug, cover closed For safety reasons, only the mentioned explosion-proof plugs fit in the sockets. The explosion-proof plugs do fit in normal sockets in accordance with CEE17. II 2 G Ex d e IIC T6/T5 II 2 D Ex tD A21 IP66 T68°C Zone 1 Zone 2 Zone 21 Zone 22 LCIE02ATEX6068 Specifications Connection Protection Cable entries Material Ambiant temperature 4mm² IP66 (with or without connected plug) for cable of 6,5-14,5mm polyamide -20°C - +40/55°C Ordering data Code No. of poles Nom. current Voltage Weight K16-024-2 2P 16A 24 VAC 0,40 kg K16-024-3 2P+E 16A 24 VAC 0,40 kg K16-110-3 2P+E 16A 110/130 VAC 0,39 kg K16-230-3 2P+E 16A 220/240 VAC 0,39 kg K16-230-4 3P+E 16A 220/240 VAC 0,58 kg K16-230-5 3P+N+E 16A 220/240 VAC 0,60 kg K16-400-4 3P+E 16A 380/415 VAC 0,61 kg K16-400-5 3P+N+E 16A 380/415 VAC 0,62 kg Dimensional sketches Product code Dimensions A B C D E F G Ø K16-024-2 42 46 54 80 160 130 210 39 K16-024-3 42 46 54 80 160 130 210 39 K16-110-3 42 46 54 80 160 130 210 39 K16-230-3 42 46 54 80 160 130 210 39 K16-230-4 56 60 68 90 160 150 230 49,5 K16-230-5 56 60 68 90 160 150 230 49,5 K16-400-4 56 60 68 90 160 150 230 49,5 K16-400-5 56 60 68 90 160 150 230 49,5 www.ysebaert.be ● info@ysebaert.be ● T +32(0)3 328 06 60 ● F +32(0)3 328 06 80 113 5 Switches, control units, sockets and plugs 4 Sockets and plugs 3 16 A Built-in wall sockets The built-in wall sockets are fitted with an integrated interruption of the poles by a double-safety device. When the plug is pulled, there will be: - an automatic and simultaneous interruption of every phase in a first explosion-proof chamber - voltage-free separation of the pins in a second explosion-proof chamber The cover can be locked in 3 positions: - with connected plug under tension - with connected plug voltage free - without plug, cover closed For safety reasons, only the mentioned explosion-proof plugs fit in the sockets. The explosion-proof plugs do fit in normal sockets in accordance with CEE17. II 2 G Ex d e IIC T6/T5 II 2 D Ex tD A21 IP66 T68°C Zone 1 Zone 2 Zone 21 Zone 22 LCIE02ATEX6068 Specifications Connection Protection Material Ambiant temperature 2x4mm² IP66 (with or without connected plug) high-quality, impact-resistant plastic -20°C - +40/55°C Ordering data Code No. of poles Nom. current Voltage Weight I16-024-2 2P 16A 24 VAC 0,25 kg I16-024-3 2P+E 16A 24 VAC 0,25 kg I16-230-3 2P+E 16A 220/240 VAC 0,27 kg I16-400-4 3P+E 16A 380/415 VAC 0,36 kg I16-400-5 3P+N+E 16A 380/415 VAC 0,39 kg Dimensional sketches 114 Product code Dimensions A B C D E I16-024-2 54 80 160 76 56 I16-024-3 54 80 160 76 56 I16-230-3 54 80 160 76 56 I16-400-4 68 90 160 76 56 I16-400-5 68 90 160 76 56 For certificates, spare parts, light intensity diagrams, etc., please consult our website: www.ysebaert.be 5 Switches, control units, sockets and plugs 4 Sockets and plugs 4 16 A Plugs The sockets are fitted with an integrated interruption of the poles by a double-safety device. When the plug is pulled, there will be: - an automatic and simultaneous interruption of every phase in a first explosion-proof chamber - voltage-free separation of the pins in a second explosion-proof chamber The cover can be locked in 3 positions: - with connected plug under tension - with connected plug voltage free - without plug, cover closed For safety reasons, only the mentioned explosion-proof plugs fit in the sockets. The explosion-proof plugs do fit in normal sockets in accordance with CEE17. II 2 G Ex d e IIC T6/T5 II 2 D Ex tD A21 IP66 T68°C Zone 1 Zone 2 Zone 21 Zone 22 LCIE02ATEX6068 Specifications Connection Cable entries Material Ambiant temperature 2,5mm² for cable of 6,5-14,5mm polyamide -40°C - +40/55°C Ordering data Code No. of poles Nom. current Voltage Weight S16-024-2 2P 16A 24 VAC 0,20 kg S16-024-3 2P+E 16A 24 VAC 0,20 kg S16-110-3 2P+E 16A 110/130 VAC 0,20 kg S16-230-3 2P+E 16A 220/240 VAC 0,20 kg S16-230-4 3P+E 16A 220/240 VAC 0,23 kg S16-230-5 3P+N+E 16A 220/240 VAC 0,28 kg S16-400-4 3P+E 16A 380/415 VAC 0,22 kg S16-400-5 3P+N+E 16A 380/415 VAC 0,27 kg Dimensional sketches Product code Dimensions A B C S16-024-2 58 152 49,5 S16-024-3 58 152 49,5 S16-110-3 58 152 49,5 S16-230-3 58 152 49,5 S16-230-4 66 154 55,5 S16-230-5 73 166 62 S16-400-4 66 154 55,5 S16-400-5 73 166 62 www.ysebaert.be ● info@ysebaert.be ● T +32(0)3 328 06 60 ● F +32(0)3 328 06 80 115 5 Switches, control units, sockets and plugs 4 Sockets and plugs 5 32 A Wall sockets The sockets are fitted with an integrated interruption of the poles by a double-safety device. When the plug is pulled, there will be: - an automatic and simultaneous interruption of every phase in a first explosion-proof chamber - voltage-free separation of the pins in a second explosion-proof chamber The cover can be locked in 3 positions: - with connected plug under tension - with connected plug voltage free - without plug, cover closed For safety reasons, only the mentioned explosion-proof plugs fit in the sockets. The explosion-proof plugs do fit in normal sockets in accordance with CEE17. II 2 G Ex d e IIC T6/T5 II 2 D Ex tD A21 IP66 T68°C Zone 1 Zone 2 Zone 21 Zone 22 LCIE02ATEX6068 Specifications Connection Earthing Protection Cable entries Material Ambiant temperature 2x6mm² 3 terminals (fed-through) IP66 (with or without connected plug) 3xM25 supplied with 1 gland (8-18,5mm) and 2 plugs high-quality, impact-resistant plastic -40°C - +50/55°C Ordering data Code No. of poles Nom. current Voltage Weight C32-230-3 2P+E 32A 220/240 VAC 1,89 kg C32-230-4 3P+E 32A 220/240 VAC 1,89 kg C32-400-4 3P+E 32A 380/415 VAC 2,00 kg C32-400-5 3P+N+E 32A 380/415 VAC 2,00 kg C32-500-4 3P+E 32A 500 VAC 2,00 kg Dimensional sketches 116 Product code Dimensions A B C D C32-230-3 140 275 155 370 C32-230-4 140 275 155 370 C32-400-4 140 275 155 370 C32-400-5 140 275 165 375 C32-500-4 140 275 155 370 For certificates, spare parts, light intensity diagrams, etc., please consult our website: www.ysebaert.be 5 Switches, control units, sockets and plugs 4 Sockets and plugs 6 32 A Couplings The couplings are fitted with an integrated interruption of the poles by a double-safety device. When the plug is pulled, there will be: - an automatic and simultaneous interruption of every phase in a first explosion-proof chamber - voltage-free separation of the pins in a second explosion-proof chamber The cover can be locked in 3 positions: - with connected plug under tension - with connected plug voltage free - without plug, cover closed For safety reasons, only the mentioned explosion-proof plugs fit in the sockets. The explosion-proof plugs do fit in normal sockets in accordance with CEE17. II 2 G Ex d e IIC T6/T5 II 2 D Ex tD A21 IP66 T68°C Zone 1 Zone 2 Zone 21 Zone 22 LCIE02ATEX6068 Specifications Connection Protection Cable entries Material Ambiant temperature 6mm² IP66 (with or without connected plug) for cable of 14-18mm polyamide -20°C - +50/55°C Ordering data Code No. of poles Nom. current Voltage Weight K32-400-4 3P+E 32A 380/415 VAC 0,82 kg Dimensional sketches Product code Dimensions A B C D E F G Ø K32-400-4 56 56 74 103 210 150 260 56 www.ysebaert.be ● info@ysebaert.be ● T +32(0)3 328 06 60 ● F +32(0)3 328 06 80 117 5 Switches, control units, sockets and plugs 4 Sockets and plugs 7 32 A Built-in wall sockets The built-in wall sockets are fitted with an integrated interruption of the poles by a double-safety device. When the plug is pulled, there will be: - an automatic and simultaneous interruption of every phase in a first explosion-proof chamber - voltage-free separation of the pins in a second explosion-proof chamber The cover can be locked in 3 positions: - with connected plug under tension - with connected plug voltage free - without plug, cover closed For safety reasons, only the mentioned explosion-proof plugs fit in the sockets. The explosion-proof plugs do fit in normal sockets in accordance with CEE17. II 2 G Ex d e IIC T6/T5 II 2 D Ex tD A21 IP66 T68°C Zone 1 Zone 2 Zone 21 Zone 22 LCIE02ATEX6068 Specifications Connection Protection Material Ambiant temperature 2x6mm² IP66 (with or without connected plug) high-quality, impact-resistant plastic -20°C - +50/55°C Ordering data Code No. of poles Nom. current Voltage Weight I32-400-4 3P+E 32A 380/415 VAC 0,65 kg Dimensional sketches 118 Product code Dimensions A B C D E I32-400-4 74 103 210 110 60 For certificates, spare parts, light intensity diagrams, etc., please consult our website: www.ysebaert.be 5 Switches, control units, sockets and plugs 4 Sockets and plugs 8 32 A Plugs The sockets are fitted with an integrated interruption of the poles by a double-safety device. When the plug is pulled, there will be: - an automatic and simultaneous interruption of every phase in a first explosion-proof chamber - voltage-free separation of the pins in a second explosion-proof chamber The cover can be locked in 3 positions: - with connected plug under tension - with connected plug voltage free - without plug, cover closed For safety reasons, only the mentioned explosion-proof plugs fit in the sockets. The explosion-proof plugs do fit in normal sockets in accordance with CEE17. II 2 G Ex d e IIC T6/T5 II 2 D Ex tD A21 IP66 T68°C Zone 1 Zone 2 Zone 21 Zone 22 LCIE02ATEX6068 Specifications Connection Cable entries Material Ambiant temperature 6mm² for cable of 14-18mm polyamide -40°C - +50/55°C Ordering data Code No. of poles Nom. current Voltage Weight S32-230-3 2P+E 32A 220/240 VAC 0,50 kg S32-230-4 3P+E 32A 220/240 VAC 0,50 kg S32-400-4 3P+E 32A 380/415 VAC 0,43 kg S32-400-5 3P+N+E 32A 380/415 VAC 0,50 kg S32-500-4 3P+E 32A 500 VAC 0,43 kg Dimensional sketches Product code Dimensions A B C S32-230-3 80 170 67 S32-230-4 80 170 67 S32-400-4 80 170 67 S32-400-5 80 195 74 S32-500-4 80 170 67 www.ysebaert.be ● info@ysebaert.be ● T +32(0)3 328 06 60 ● F +32(0)3 328 06 80 119 5 Switches, control units, sockets and plugs 4 Sockets and plugs 9 63 A Wall sockets The 63A sockets and plugs differ construction-wise from the versions with less power. The voltage is cut off by means of a lockable switch instead of an internal switching mechanism. The auxiliary contact can be integrated into the control circuit. Zone 1 Specifications Zone 2 Connection Protection Cable entries Material Ambiant temperature 35mm² IP65 1 gland M50 and 1 plug M25 enclosure made of impact-resistant plastic and polyamide socket -30°C - +40/55°C II 2 G Ex d e IIC T6/T5 II 2 D Ex tD A21 IP66 T90°C Zone 21 Zone 22 LCIE99ATEX6004 Ordering data Code No. of poles Nom. current Voltage Break power (kW-AC3) Weight C63-230-4 3P+PE 63A 200-250 VAC 15 8 kg C63-400-4 3P+PE 63A 380-415 VAC 22 8 kg C63-400-5 3P+N+PE 63A 380-415 VAC 22 8 kg C63-500-4 3P+PE 63A 480-500 VAC 18,5 8 kg Dimensional sketches 120 For certificates, spare parts, light intensity diagrams, etc., please consult our website: www.ysebaert.be 5 Switches, control units, sockets and plugs 4 Sockets and plugs 10 63 A Plugs The 63A sockets and plugs differ construction-wise from the versions with less power. The voltage is cut off by means of a lockable switch instead of an internal switching mechanism. The auxiliary contact can be integrated into the control circuit. Zone 1 Specifications Zone 2 Connection Protection Cable entries Material Ambiant temperature 35mm² IP65 1 gland M50 and 1 plug M25 polyamide -30°C - +40/55°C II 2 G Ex d e IIC T6/T5 II 2 D Ex tD A21 IP66 T90°C Zone 21 Zone 22 LCIE99ATEX6004 Ordering data Code No. of poles Nom. current Voltage Weight S63-230-4 3P+PE 63A 200-250 VAC 1 kg S63-400-4 3P+PE 63A 380-415 VAC 1 kg S63-400-5 3P+N+PE 63A 380-415 VAC 1 kg S63-500-5 3P+PE 63A 480-500 VAC 1 kg Dimensional sketches www.ysebaert.be ● info@ysebaert.be ● T +32(0)3 328 06 60 ● F +32(0)3 328 06 80 121 5 Switches, control units, sockets and plugs 4 Sockets and plugs 11 125 A Wall sockets The 125A sockets and plugs differ construction-wise from the versions with less power. The voltage is cut off by means of a lockable switch instead of an internal switching mechanism. The auxiliary contact can be integrated into the control circuit. Zone 1 Specifications Zone 2 Connection Protection Cable entries Material Ambiant temperature 120mm² IP66 1 gland M63 and 1 plug M25 enclosure in stainless steel 316L, socket in polyamide -30°C - +40/55°C II 2 G Ex d e IIC T6/T5 II 2 D Ex tD A21 IP66 T90°C Zone 21 Zone 22 LCIE99ATEX6031 Ordering data Code No. of poles Nom. current Voltage Break power (kW-AC3) Weight C125-400-4 3P+PE 125A 480-500 VAC 15 16 kg C125-400-5 3P+N+PE 125A 480-500 VAC 22 16 kg Dimensional sketches 122 For certificates, spare parts, light intensity diagrams, etc., please consult our website: www.ysebaert.be 5 Switches, control units, sockets and plugs 4 Sockets and plugs 12 125 A Plugs The 63-125 sockets and plugs differ construction-wise from the versions with less power. The voltage is cut off by means of a lockable switch instead of an internal switching mechanism. The auxiliary contact can be integrated into the control circuit. Zone 1 Specifications Zone 2 Connection Protection Cable entries Material Ambiant temperature 120mm² IP66 1 gland M63 and 1 plug M25 polyamide -30°C - +40/55°C II 2 G Ex d e IIC T6/T5 II 2 D Ex tD A21 IP66 T90°C Zone 21 Zone 22 LCIE99ATEX6031 Ordering data Code No. of poles Nom. current Voltage S125-400-4 3P+PE 125A 480-500 VAC Weight 1,1 kg S125-400-5 3P+N+PE 125A 480-500 VAC 1,1 kg Dimensional sketches www.ysebaert.be ● info@ysebaert.be ● T +32(0)3 328 06 60 ● F +32(0)3 328 06 80 123 5 Switches, control units, sockets and plugs 5 Installation switches 1 Installation switches 16A - 250VCA These installation switches meet the current demands regarding ease of use (large control surface) and connection space. A protective flange prevents unwanted operation. Specifications Material Protection Connection terminals Rated voltage Nominal current Cable entry Ambiant temperature Mounting impact-resistant plastic IP66 2 x 2,5 mm² (earthing 4 x 2,5 mm²) 250VAC 16A M25 gland (for cable of Ø 8-17mm) -55°C - +40°C 2 mounting holes II 2 G Ex d e IIC T6 II 2 D Ex tD A21 IP66 T80°C Zone 1 Zone 2 Zone 21 Zone 22 PTB98ATEX3121 Ordering data Code Diagram Gland entries GHG2732000R0017 1 x M25 GHG2732000R0018 2 x M25 GHG2736000R0011 1 x M25 Dimensional sketches 124 For certificates, spare parts, light intensity diagrams, etc., please consult our website: www.ysebaert.be 5 Switches, control units, sockets and plugs 6 Work switches & safety switches 1 10 - 180A work switches Safety switches are used to cut power to electrical installations during maintenance or other work. Safety switches (EMERGENCY STOP function) are characterised by their yellow/red padlock bracket and a forced opening of the main contacts (according to EN60024-1); standard safety switches have a black padlock bracket. The switches can be locked with 3 padlocks. The enclosures are made of glass-fibre reinforced polyester and so are suited for applications in aggressive and heavy-duty conditions. II 2 G Ex d e IIC T6 II 2 G Ex d e ia II C T6 II 2 D Ex tD A21 IP66 T80°C Zone 1 Zone 2 Zone 21 Zone 22 PTB00ATEX1074 PTB99ATEX1161 Specifications Protection PTB00ATEX1091 IP66 PTB99ATEX1164 Ordering data Code Material Terminal No. of poles Nom. current (A) Gland entries Weight Ambiant temp. GHG2610005R0009 impact-resistant polyamide 2 x 2,5 mm² 3+1NO 10 2xM25 + 1xM20 0,55 kg -55°C - +52°C GHG2622301R0001 glass-fibre reinforced polyester 2 x 4 mm² 3+1NO 20 2xM32 + 1xM25 1,50 kg -55°C - +55°C GHG2622601R0001 glass-fibre reinforced polyester 2 x 4 mm² 6+1NO/NC 20 4xM32 + 1xM25 2,30 kg -55°C - +55°C GHG2632301R0001 glass-fibre reinforced polyester 2 x 16 mm² 3+1NO 40 2xM40 + 1xM25 2,30 kg -55°C - +55°C GHG2630050R0001 glass-fibre reinforced polyester 2 x 16 mm² 6+1NO/NC 40 4xM40 + 1xM25 6,50 kg -55°C - +55°C GHG2640020R0001 glass-fibre reinforced polyester 2 x 25 mm² 3+1NO/NC 80 2xM50 + 1xM25 6,50 kg -36°C - +52°C GHG2640021R0001 glass-fibre reinforced polyester 2 x 25 mm² 6+1NO/NC 80 4xM50 + 1xM25 9,00 kg -36°C - +52°C GHG2650010R0001 glass-fibre reinforced polyester 1 x 50/70 mm² 3+1NO/NC 125 2xM63 + 1xM25 16,00 kg -55°C - +45°C GHG2660006R0001 glass-fibre reinforced polyester 1 x 120 mm² 3+1NO/NC 180 2xM63 + 1xM25 16,50 kg -55°C - +45°C www.ysebaert.be ● info@ysebaert.be ● T +32(0)3 328 06 60 ● F +32(0)3 328 06 80 125 5 Switches, control units, sockets and plugs 6 Work switches & safety switches 1 10 - 180A work switches Dimensional sketches 10A 20A / 40A-3P 40A-6P / 80A / 125A / 180A Product code Dimensions A B C D E F GHG2610005R0009 84 68,5 102 61,5 112 5,5 GHG2622301R0001 110 96 170 150 129 7 13 GHG2622601R0001 140 123-126 225 197 156 7 8 GHG2632301R0001 140 123-126 225 197 156 7 8 GHG2630050R0001 271 247 271 247 275 7 GHG2640020R0001 271 247 271 247 275 GHG2640021R0001 271 247 271 247 GHG2650010R0001 271 247 544 GHG2660006R0001 271 247 544 G H I 8,5 80 11 12 211 7 11 12 211 295 7 11 12 211 520 275 7 11 12 211 520 275 7 11 12 211 Switching capacity at AC3 126 I nom 230V 400V 500V 690V 10A 10A 10A 10A - 20A 20A 20A 16A 10A 40A 40A 40A 40A 30A 80A 80A 80A 80A 80A 125A 125A 125A 125A 110A 180A 180A 180A 150A 125A For certificates, spare parts, light intensity diagrams, etc., please consult our website: www.ysebaert.be 5 Switches, control units, sockets and plugs 6 Work switches & safety switches 2 10 - 180A safety switches Safety switches are used to cut power to electrical installations during maintenance or other work. Safety switches (EMERGENCY STOP function) are characterised by their yellow/red padlock bracket and a forced opening of the main contacts (according to EN60024-1); standard safety switches have a black padlock bracket. The switches can be locked with 3 padlocks. The enclosures are made of glass-fibre reinforced polyester and so are suited for applications in aggressive and heavy-duty conditions. II 2 G Ex d e IIC T6 II 2 G Ex d e ia II C T6 II 2 D Ex tD A21 IP66 T80°C Zone 1 Zone 2 Zone 21 Zone 22 PTB00ATEX1074 PTB99ATEX1161 Specifications Protection PTB00ATEX1091 IP66 PTB99ATEX1164 Ordering data Code Material Terminal No. of poles Nom. current (A) Gland entries Weight Ambiant temp. GHG2610005R0010 impact-resistant polyamide 2 x 2,5 mm² 3+1NO 10 2xM25 + 1xM20 0,55 kg -55°C - +52°C GHG2622301R0002 glass-fibre reinforced polyester 2 x 4 mm² 3+1NO 20 2xM32 + 1xM25 1,50 kg -55°C - +55°C GHG2622601R0002 glass-fibre reinforced polyester 2 x 4 mm² 6+1NO/NC 20 4xM32 + 1xM25 2,30 kg -55°C - +55°C GHG2632301R0002 glass-fibre reinforced polyester 2 x 16 mm² 3+1NO 40 2xM40 + 1xM25 2,30 kg -55°C - +55°C GHG2630050R0002 glass-fibre reinforced polyester 2 x 16 mm² 6+1NO/NC 40 4xM40 + 1xM25 6,50 kg -55°C - +55°C GHG2640020R0002 glass-fibre reinforced polyester 2 x 25 mm² 3+1NO/NC 80 2xM50 + 1xM25 6,50 kg -36°C - +52°C GHG2640021R0002 glass-fibre reinforced polyester 2 x 25 mm² 6+1NO/NC 80 4xM50 + 1xM25 9,00 kg -36°C - +52°C GHG2650010R0002 glass-fibre reinforced polyester 1 x 50/70 mm² 3+1NO/NC 125 2xM63 + 1xM25 16,00 kg -55°C - +45°C GHG2660006R0002 glass-fibre reinforced polyester 1 x 120 mm² 3+1NO/NC 180 2xM63 + 1xM25 16,50 kg -55°C - +45°C www.ysebaert.be ● info@ysebaert.be ● T +32(0)3 328 06 60 ● F +32(0)3 328 06 80 127 5 Switches, control units, sockets and plugs 6 Work switches & safety switches 2 10 - 180A safety switches Dimensional sketches 10A 20A / 40A-3P 40A-6P / 80A / 125A / 180A Product code Dimensions A B C D E F GHG2610005R0010 84 68,5 102 61,5 112 5,5 GHG2622301R0002 110 96 170 150 129 7 13 GHG2622601R0002 140 123-126 225 197 156 7 8 GHG2632301R0002 140 123-126 225 197 156 7 8 GHG2630050R0002 271 247 271 247 275 7 GHG2640020R0002 271 247 271 247 275 GHG2640021R0002 271 247 271 247 GHG2650010R0002 271 247 544 GHG2660006R0002 271 247 544 G H I 8,5 80 11 12 211 7 11 12 211 295 7 11 12 211 520 275 7 11 12 211 520 275 7 11 12 211 Switching capacity at AC3 128 I nom 230V 400V 500V 690V 10A 10A 10A 10A - 20A 20A 20A 16A 10A 40A 40A 40A 40A 30A 80A 80A 80A 80A 80A 125A 125A 125A 125A 110A 180A 180A 180A 150A 125A For certificates, spare parts, light intensity diagrams, etc., please consult our website: www.ysebaert.be 5 Switches, control units, sockets and plugs 7 Motor circuit breakers 1 Motor circuit breakers 0,1 - 25A Motor circuit breakers are used to secure (thermally and magnetically) explosion-proof motors against overload, short-circuits and phase loss. The characteristics are: the forced opening of the main contacts, the padlock bracket for 3 padlocks and the clear indication of the position of the switch. The enclosures are made of glass-fibre reinforced polyester and are thus suited for applications under aggressive and heavy-duty conditions. II 2 G Ex d e IIC T5/T6 II 2 D Ex tD A21 IP66 T80°C Zone 1 Zone 2 Zone 21 Zone 22 PTB99ATEX1162 Specifications Material Protection Connection glass-fibre reinforced polyester IP 66 up to 10mm² (2,5 mm² for secondary contacts) max. 690V max. 25A (secondary contact 2A) ± 2,5 kg Rated voltage Nominal current Weight On request • undervoltage protection 230V or 400V - decommutation between protection 15-75% Vc - commutation from V < 80% Vc Ordering data Code Setting range GHG6351101R0101 0.1 A - 0.16 A GHG6351102R0101 0.1 A - 0.16 A GHG6351101R0102 0.16 A - 0.25 A GHG6351102R0102 0.16 A - 0.25 A GHG6351101R0103 0.25 A - 0.40 A GHG6351102R0103 0.25 A - 0.40 A GHG6351101R0104 0.40 A - 0.63 A GHG6351102R0104 0.40 A - 0.63 A GHG6351101R0105 0.63 A - 1.0 A GHG6351102R0105 0.63 A - 1.0 A GHG6351101R0106 1.0 A - 1.6 A GHG6351102R0106 1.0 A - 1.6 A GHG6351101R0107 1.6 A - 2.5 A GHG6351102R0107 1.6 A - 2.5 A GHG6351101R0108 2.5 A - 4.0 A GHG6351102R0108 2.5 A - 4.0 A GHG6351101R0109 4.0 A - 6.3 A GHG6351102R0109 4.0 A - 6.3 A GHG6351101R0110 6.3 A - 9.0 A GHG6351102R0110 6.3 A - 9.0 A GHG6351101R0111 9.0 A - 12.5 A GHG6351102R0111 9.0 A - 12.5 A GHG6351101R0112 12.5 A - 16 A GHG6351102R0112 12.5 A - 16 A GHG6351101R0113 16 A - 20 A GHG6351102R0113 16 A - 20 A GHG6351101R0114 20 A - 25 A GHG6351102R0114 20 A - 25 A Auxiliary contact 1NO + 1NC 1NO + 1NC 1NO + 1NC 1NO + 1NC 1NO + 1NC 1NO + 1NC 1NO + 1NC 1NO + 1NC 1NO + 1NC 1NO + 1NC 1NO + 1NC 1NO + 1NC 1NO + 1NC 1NO + 1NC Gland entries Temp. class Ambiant temp. 2 x M25 (Ø8-17mm) T6 -20°C - +40°C 2 x M25 (Ø8-17mm) T6 -20°C - +40°C 2 x M25 (Ø8-17mm) T6 -20°C - +40°C 2 x M25 (Ø8-17mm) T6 -20°C - +40°C 2 x M25 (Ø8-17mm) T6 -20°C - +40°C 2 x M25 (Ø8-17mm) T6 -20°C - +40°C 2 x M25 (Ø8-17mm) T6 -20°C - +40°C 2 x M25 (Ø8-17mm) T6 -20°C - +40°C 2 x M25 (Ø8-17mm) T6 -20°C - +40°C 2 x M25 (Ø8-17mm) T6 -20°C - +40°C 2 x M25 (Ø8-17mm) T6 -20°C - +40°C 2 x M25 (Ø8-17mm) T6 -20°C - +40°C 2 x M25 (Ø8-17mm) T6 -20°C - +40°C 2 x M25 (Ø8-17mm) T6 -20°C - +40°C 2 x M25 (Ø8-17mm) T6 -20°C - +40°C 2 x M25 (Ø8-17mm) T6 -20°C - +40°C 2 x M25 (Ø8-17mm) T6 -20°C - +40°C 2 x M25 (Ø8-17mm) T6 -20°C - +40°C 2 x M32 (Ø12-21mm) T6 -20°C - +40°C 2 x M32 (Ø12-21mm) T6 -20°C - +40°C 2 x M32 (Ø12-21mm) T6 -20°C - +40°C 2 x M32 (Ø12-21mm) T6 -20°C - +40°C 2 x M32 (Ø12-21mm) T6 -20°C - +55°C 2 x M32 (Ø12-21mm) T6 -20°C - +55°C 2 x M32 (Ø12-21mm) T5 -20°C - +55°C 2 x M32 (Ø12-21mm) T5 -20°C - +55°C 2 x M32 (Ø12-21mm) T5 -20°C - +55°C 2 x M32 (Ø12-21mm) T5 -20°C - +55°C Dimensional sketches www.ysebaert.be ● info@ysebaert.be ● T +32(0)3 328 06 60 ● F +32(0)3 328 06 80 129 5 Switches, control units, sockets and plugs 8 Foot switches 1 Foot switches These installation switches meet the current demands regarding ease of use (large control surface) and connection space. A protective flange prevents unwanted operation. Specifications Material Protection Rated voltage Mechanical life Cable entry Ambiant temperature zink alloy (Zamak) IP66 max. 250VAC 5 million cycles 1 PG16 gland (for cable of Ø 5-13mm) 1 plug PG16 -20°C - +60°C II 2 D Ex tD A21 IP66 T85°C Zone 1 Zone 2 Zone 21 Zone 22 INERIS04ATEX0042 Ordering data Code Contact blocks Service control XPEWM110 1 NO+NC 1 step Colour blue XPEWR110 1 NO+NC 1 step orange XPEWM111 2 NC+NO 1 step blue XPEWR111 2 NC+NO 1 step orange XPEWM211 2 NC+NO 2 step blue XPEWR211 2 NC+NO 2 step orange Dimensional sketches 130 For certificates, spare parts, light intensity diagrams, etc., please consult our website: www.ysebaert.be 6 Heating 1 Tubular heaters .......................................................................................... 133 1 FAW & FAW-C series for zone 1 and 2 ........................................... 133 2 FWD & FWDT series for zone 1, 2, 21 and 22 ............................... 135 2 Electric heaters .......................................................................................... 137 1 FLR series....................................................................................... 137 3 Enclosure heaters ...................................................................................... 138 1 HEF series ...................................................................................... 138 4 Thermostat ................................................................................................. 139 1 HFT series - internally adjustable ................................................... 139 2 AFT series - externally adjustable................................................... 140 www.ysebaert.be ● info@ysebaert.be ● T +32(0)3 328 06 60 ● F +32(0)3 328 06 80 131 6 Heating 1 Tubular heaters 1 FAW & FAW-C series for zone 1 and 2 These finned tubular heaters are designed to heat, among other things, analysis chambers, small work, storage areas and similar applications, warehouses, ... located in zone 1 or 2 hazardous areas where the flammable atmosphere is a group IIA, IIB or IIC gas. The standard version comes with a protective cage and is suited for floor mounting. Special brackets for wall mounting are available on request. II 2 G Ex e II T3/T4 Zone 1 Zone 2 Zone 21 Zone 22 LCIE00ATEX6013X Specifications Earthing Protection Protective grid Elements Cable entry Mounting in- and external earthing bolt IP66 standard individually replaceable 1x M20 x 1,5 floor mounting by means of supplied mounting feet -60°C - +40°C Ambiant temperature On request • • • • • if required the heaters can be controlled of remote mounted thermostats available for use in safe or hazardous areas enclosure in stainless steel (FAW) T2 : -60°C - +60°C other tensions brackets for wall mounting Ordering data Code Range Housing Voltage Power Temp. class No. of supports Weight FAWC0250-T3-240 Compact stainless steel 240V 250W T3 2 5 kg FAWC0500-T3-240 Compact stainless steel 240V 500W T3 2 6 kg FAWC0750-T3-240 Compact stainless steel 240V 750W T3 2 6 kg FAWC1000-T3-240 Compact stainless steel 240V 1000W T3 2 9 kg FAW0250-T3-240 Standard lightweight coated mild steel 240V 250W T3 2 8 kg FAW0500-T3-240 Standard lightweight coated mild steel 240V 500W T3 2 10 kg FAW0750-T3-240 Standard lightweight coated mild steel 240V 750W T3 2 12 kg FAW1000-T3-240 Standard lightweight coated mild steel 240V 1000W T3 3 14 kg FAW1500-T3-240 Standard lightweight coated mild steel 240V 1500W T3 3 20 kg FAW2000-T3-240 Standard lightweight coated mild steel 240V 2000W T3 3 32 kg FAW2500-T3-240 Standard lightweight coated mild steel 240V 2500W T3 3 38 kg FAW3000-T3-240 Standard lightweight coated mild steel 240V 3000W T3 3 42 kg FAW0250-T4-240 Standard lightweight coated mild steel 240V 250W T4 3 13 kg FAW0500-T4-240 Standard lightweight coated mild steel 240V 500W T4 3 17 kg FAW0750-T4-240 Standard lightweight coated mild steel 240V 750W T4 3 21 kg FAW1000-T4-240 Standard lightweight coated mild steel 240V 1000W T4 3 33 kg FAW1250-T4-240 Standard lightweight coated mild steel 240V 1250W T4 3 38 kg FAW1500-T4-240 Standard lightweight coated mild steel 240V 1500W T4 3 42 kg www.ysebaert.be ● info@ysebaert.be ● T +32(0)3 328 06 60 ● F +32(0)3 328 06 80 133 6 Heating 1 Tubular heaters 1 FAW & FAW-C series for zone 1 and 2 Dimensional sketches 134 Product code Dimensions A B C FAWC0250-T3-240 350 160 282 FAWC050-T3-240 350 160 282 FAWC0750-T3-240 615 160 545 FAWC1000-T3-240 615 160 545 FAW0250-T3-240 971 160 860 FAW0500-T3-240 971 160 860 FAW0750-T3-240 971 160 860 FAW1000-T3-240 1221 160 1120 FAW1500-T3-240 1741 160 1640 FAW2000-T3-240 1741 272 1640 FAW2500-T3-240 1741 272 1640 FAW3000-T3-240 1741 272 1640 FAW0250-T4-240 1886 160 1784 FAW0500-T4-240 1886 160 1784 FAW0750-T4-240 1886 160 1784 FAW1000-T4-240 1886 272 1784 FAW1250-T4-240 1886 272 1784 FAW1500-T4-240 1886 272 1784 For certificates, spare parts, light intensity diagrams, etc., please consult our website: www.ysebaert.be 6 Heating 1 Tubular heaters 2 FWD & FWDT series for zone 1, 2, 21 and 22 These finned tubular heaters are designed for use in small work or storage areas which are located in zone 1 and 2 or zone 21 and 22 hazardous areas where the flammable atmosphere is a IIA, IIB or IIC gas group. The FWDT range comes with an easy to adjust external thermostat 0-40°C. Specifications Protection Elements Voltage Mounting Ambiant temperature IP66 individually replaceable 230-254V floor or wall mounting by means of supplied mounting feet -60°C - +40°C II 2 G Ex d IIC T2-T4 II 2 D Ex tD A21 IP66 T300°C-T135°C Zone 1 Zone 2 Zone 21 Zone 22 LCIE04ATEX6016X On request • • • enclosure in stainless steel (FWD) T2 : -60°C - +60°C 110V Ordering data Code Housing Power Temp. class Max. surface temp. Thermostat Cable entry Weight FWD-500-T3-230 lightweight coated mild steel 500W T3 200°C 2 x M20 9 kg FWD-1000-T3-230 lightweight coated mild steel 1000W T3 200°C 2 x M20 12 kg FWD-1500-T3-230 lightweight coated mild steel 1500W T3 200°C 2 x M20 17 kg FWD-2000-T3-230 lightweight coated mild steel 2000W T3 200°C 2 x M20 20 kg FWD-500-T4-230 lightweight coated mild steel 500W T4 135°C 2 x M20 12 kg FWD-750-T4-230 lightweight coated mild steel 750W T4 135°C 2 x M20 17 kg FWD-1000-T4-230 lightweight coated mild steel 1000W T4 135°C 2 x M20 20 kg FWDT-500-T3-230 powder coated aluminium 500W T3 200°C 2 x M25 9 kg FWDT-1000-T3-230 powder coated aluminium 1000W T3 200°C 2 x M25 12 kg FWDT-1500-T3-230 powder coated aluminium 1500W T3 200°C 2 x M25 17 kg FWDT-2000-T3-230 powder coated aluminium 2000W T3 200°C 2 x M25 20 kg FWDT-500-T4-230 powder coated aluminium 500W T4 135°C 2 x M25 12 kg FWDT-750-T4-230 powder coated aluminium 750W T4 135°C 2 x M25 17 kg FWDT-1000-T4-230 powder coated aluminium 1000W T4 135°C 2 x M25 20 kg www.ysebaert.be ● info@ysebaert.be ● T +32(0)3 328 06 60 ● F +32(0)3 328 06 80 135 6 Heating 1 Tubular heaters 2 FWD & FWDT series for zone 1, 2, 21 and 22 Dimensional sketches FWD FWDT 136 Product code Dimensions A B FWD-500-T3-230 800 670 FWD-1000-T3-230 1300 1170 FWD-1500-T3-230 1900 1770 FWD-2000-T3-230 2450 2320 FWD-500-T4-230 1300 1170 FWD-750-T4-230 1900 1770 FWD-1000-T4-230 2450 2320 FWDT-500-T3-230 800 670 FWDT-1000-T3-230 1300 1170 FWDT-1500-T3-230 1900 1770 FWDT-2000-T3-230 2450 2320 FWDT-500-T4-230 1300 1170 FWDT-750-T4-230 1900 1770 FWDT-1000-T4-230 2450 2320 For certificates, spare parts, light intensity diagrams, etc., please consult our website: www.ysebaert.be 6 Heating 2 Electric heaters 1 FLR series These electric heaters are designed to heat, among other things, analysis chambers, small work, storage areas and similar applications, warehouses, ... located in zone 1 and 2 (gas) and zone 21 and 22 (dust). The equipment is formed of a metallic enclosure including a liquid (water and glycol) heated by an immerged heater. These heaters can be ordered with or without an external adjustable thermostat mounted on the equipment. II 2 G Ex d IIC T6 II 2 D Ex tD A21 IP66 T85°C Zone 1 Zone 2 Zone 21 Zone 22 LCIE00ATEX6012X Specifications Housing Elements Protection Voltage Cable entry Mounting Ambiant temperature coated steel Incoloy 825 IP66 240V AC (single phase) 2x M25 x 1,5 floor mounting by welded-on feet brackets -20°C - +40°C On request • • loose thermostat other voltages Ordering data Code Power Thermostat Weight FLR1 1000W 47 kg FLR1-A 1000W 47 kg FLR2 2000W 94 kg FLR2-A 2000W 94 kg FLR3 3000W 140 kg FLR3-A 3000W 140 kg Dimensional sketches Product code Dimensions A B C FLR1 540 495 360 FLR2 1080 1035 900 FLR3 1620 1575 1440 FLR1-A 540 495 360 FLR2-A 1080 1035 900 FLR3-A 1620 1575 1440 www.ysebaert.be ● info@ysebaert.be ● T +32(0)3 328 06 60 ● F +32(0)3 328 06 80 137 6 Heating 3 Enclosure heaters 1 HEF series The HEF range of enclosure heaters has been designed for anticondensation, frost protection and temperature control where control panels and monitoring cabinets are located within zone 1 & 2 (gas). This heater has a low surface temperature and is self-regulating. Mounting of the heater can be in any orientation. II 2 G Ex e II T4 Zone 1 Zone 2 Zone 21 Zone 22 LCIE02ATEX6123X Specifications Housing Voltage Mounting Ambiant temperature stainless steel 240V AC (single phase) mounting feet for M6 fixing -50°C - +80°C On request • 110V (single phase) Ordering data Code Power Weight HEF30/240 30W 0,7 kg HEF50/240 50W 1,0 kg HEF100/240 100W 1,5 kg HEF200/240 200W 3,0 kg HEF500/240 500W 6,5 kg Dimensional sketches 138 Product code Dimensions A B C D E F G HEF30/240 130 73 center 1 N/A N/A N/A HEF50/240 266 100 60 3 N/A 142 22 HEF100/240 290 180 140 4 75 165 50 HEF200/240 550 180 100 5 243 215 35 HEF500/240 700 340 300 5 300 275 50 For certificates, spare parts, light intensity diagrams, etc., please consult our website: www.ysebaert.be 6 Heating 4 Thermostat 1 HFT series - internally adjustable The HFT is designed for the temperature control of work or storage areas, in conjunction with a Hazardous Area air heater. Specifications II 2 G Ex d IIC T6 Zone 1 Housing Protection Earthing Voltage Current Cable entry Mounting Ambiant temperature stainless steel IP67 internal and external max. 250V 16A 2 x M20 2 x M6 -60°C - +60°C Zone 2 Zone 21 Zone 22 LCIE99ATEX6017X Ordering data Code Range Voltage HFT40 0°C - +40°C 250V HFT60 0°C - +60°C 250V Dimensional sketches www.ysebaert.be ● info@ysebaert.be ● T +32(0)3 328 06 60 ● F +32(0)3 328 06 80 139 6 Heating 4 Thermostat 2 AFT series - externally adjustable The AFT is designed for the temperature control of work or storage areas, in conjunction with a Hazardous Area air heater. This thermostat is externally adjustable. Specifications Housing Protection Earthing Voltage Current Cable entry Mounting Ambiant temperature stainless steel IP67 internal and external max. 250V 16A 2 x M20 2 x M6 - 60°C - + 60°C II 2 G Ex d IIC T6 II 2 D Ex tD A21 IP6X T85°C Zone 1 Zone 2 Zone 21 Zone 22 LCIE99ATEX6017X Ordering data Code Range Voltage AFT40 0°C - +40°C 250V AFT60 0°C - +60°C 250V Dimensional sketches 140 For certificates, spare parts, light intensity diagrams, etc., please consult our website: www.ysebaert.be 7 Man - machine interface 1 Digital indicator........................................................................................... 143 1 D122 series ..................................................................................... 143 2 Message display ........................................................................................ 146 1 TA125 series ................................................................................... 146 3 Modular Ex-PC ........................................................................................... 148 1 PC100 series .................................................................................. 148 4 Keyboard and Trackball ............................................................................. 150 1 KB/TB/KI 153 series........................................................................ 150 www.ysebaert.be ● info@ysebaert.be ● T +32(0)3 328 06 60 ● F +32(0)3 328 06 80 141 7 Man - machine interface 1 Digital indicator 1 D122 series The digital indicator D122 indicates measured values of intrinsically safe current circuits from 4 up to 20 mA in hazardous areas. The device is powered by measure circuit, therefore an extra power supply or batteries are unnescessary. The indicator measures the current, scales the measured value and displays finally the result on the LCD. The internal 24 bit A/D conversion achieves a stable indication even at 4 1/2 digit resolution. For trend analysis, the measured signal is also be displayed on a 41 segment bargraph. It’s possible to scale the bargraph separately. The indicator D122 is available in several housings. Furthermore with alarm monitoring option the indicator has two intrinsically safe alarm outputs. These outputs change their state, when the measured value exceeds its alarm limits. It is possible to configure the outputs as normal open or normal closed circuits. Additional the alarm limits appear graphically on a second bargraph. On one look you’re sure that the measured value is in its limits. There’s also the possibility to use the display as “counter” which gives the sum of the measured values (type D122.Z) II 2 (1) G Ex ia IIC T6 Gb Zone 1 Zone 2 Zone 21 Zone 22 On request • • • • • • • alarm monitoring: two intrinsically safe alarm outputs additional limit bargraph limit function with hysteresis and time delay normal open or normal closed circuit principle curve fitting ambiant temperature -20°C - +60°C version for zone 21 and 22 Ergonomics: • μ-processor technology for extensive configuration • scaleable by keyboard and display, without reference current • separately scaleable bargraph (zoom) • current control button • keeps the configuration by turn off • ability to change configuration during operation • exchangeable dimension signs Specifications Protection Housing Decimal points Limit monitoring Alarm limits display Measurement circuit limits Alarm terminal limits Measurement circuit Current control button Symbols Temperature coefficient Ambiant temperature Front panel up to IP55 - with sealed keyboard IP65 According to control panel standard DIN43700 selectable by keyboard By means of intrinsically safe control circuits (e.g. NAMUR or DIN19234) via bargraph, flashing ‘max.’ or ‘min.’ display (only types A.0, A.3 en A.5) see certificate TÜV99ATEX1488 see certificate TÜV99ATEX1488 intrinsically safe measurement circuit 4-20 mA, voltage drop ca. 1V direct display of the current in measurement circuit selectable with defined symbols < 0,01 % of measure range / K -10°C - +45°C www.ysebaert.be ● info@ysebaert.be ● T +32(0)3 328 06 60 ● F +32(0)3 328 06 80 143 7 Man - machine interface 1 Digital indicator 1 D122 series Ordering data Code 144 Description Material Digital height Display indication Display range Bargraph D122.A.0.0 indicator glass fibre reinforced noryl 15 mm 4 1/2-digits 7-segment LCD -19999 ... +19999 Digital output 41 segments D122.A.0.2 indicator glass fibre reinforced noryl 15 mm 4 1/2-digits 7-segment LCD -19999 ... +19999 41 segments with 2 digital outputs D122.A.0.3 indicator glass fibre reinforced noryl 15 mm 4 1/2-digits 7-segment LCD -19999 ... +19999 41 segments with reset input and pulse output D122.A.3.0 indicator glass fibre reinforced noryl 30 mm 4 1/2-digits 7-segment LCD -19999 ... +19999 41 segments D122.A.3.2 indicator glass fibre reinforced noryl 30 mm 4 1/2-digits 7-segment LCD -19999 ... +19999 41 segments with 2 digital outputs D122.A.3.3 indicator glass fibre reinforced noryl 30 mm 4 1/2-digits 7-segment LCD -19999 ... +19999 41 segments with reset input and pulse output D122.A.5.0 indicator ABS 30 mm 4 1/2-digits 7-segment LCD -19999 ... +19999 41 segments -19999 ... +19999 41 segments with 2 digital outputs 41 segments with reset input and pulse output D122.A.5.2 indicator ABS 30 mm 4 1/2-digits 7-segment LCD D122.A.5.3 indicator ABS 30 mm 4 1/2-digits 7-segment LCD -19999 ... +19999 D122.A.6.0 indicator ABS 50 mm 3 1/2-digits LCD -1999 ... +1999 D122.A.6.2 indicator ABS 50 mm 3 1/2-digits LCD -1999 ... +1999 with 2 digital outputs D122.A.6.3 indicator ABS 50 mm 3 1/2-digits LCD -1999 ... +1999 with reset input and pulse output D122.Z.0.0 totalizer glass fibre reinforced noryl 15 mm 5-digits 7-segment LCD 00000 ... +19999 41 segments D122.Z.0.2 totalizer glass fibre reinforced noryl 15 mm 5-digits 7-segment LCD 00000 ... +19999 41 segments with 2 digital outputs D122.Z.0.3 totalizer glass fibre reinforced noryl 15 mm 5-digits 7-segment LCD 00000 ... +19999 41 segments with reset input and pulse output D122.Z.3.0 totalizer glass fibre reinforced noryl 30 mm 5-digits 7-segment LCD 00000 ... +19999 41 segments D122.Z.3.2 totalizer glass fibre reinforced noryl 30 mm 5-digits 7-segment LCD 00000 ... +19999 41 segments with 2 digital outputs D122.Z.3.3 totalizer glass fibre reinforced noryl 30 mm 5-digits 7-segment LCD 00000 ... +19999 41 segments with reset input and pulse output D122.Z.5.0 totalizer ABS 30 mm 5-digits 7-segment LCD 00000 ... +19999 41 segments D122.Z.5.2 totalizer ABS 30 mm 5-digits 7-segment LCD 00000 ... +19999 41 segments with 2 digital outputs D122.Z.5.3 totalizer ABS 30 mm 5-digits 7-segment LCD 00000 ... +19999 41 segments with reset input and pulse output D122.Z.6.0 totalizer ABS 50 mm 5-digits 7-segment LCD 00000 ... +19999 41 segments D122.Z.6.2 totalizer ABS 50 mm 5-digits 7-segment LCD 00000 ... +19999 41 segments with 2 digital outputs D122.Z.6.3 totalizer ABS 50 mm 5-digits 7-segment LCD 00000 ... +19999 41 segments with reset input and pulse output For certificates, spare parts, light intensity diagrams, etc., please consult our website: www.ysebaert.be 7 Man - machine interface 1 Digital indicator 1 D122 series Dimensional sketches D122.*.0 D122. .0 D122.*.3 D122.*.6 D122.*.5 www.ysebaert.be ● info@ysebaert.be ● T +32(0)3 328 06 60 ● F +32(0)3 328 06 80 145 7 Man - machine interface 2 Message display 1 TA125 series The field text display TA125 indicates arbitrary messages, warnings or hints in the hazardous area zone 1. It’s large (58 x 244 mm), reflective display with a figure height of 15 mm can easily be read up to a distance of five meters. The display is organised into 4 rows with 40 characters per each row. The TA125 receives the messages for instance from a PC or DCS located in safe area. The interface TI125 serves as intrinsically safe barrier and power supply. It can be equiped with several bus modules (RS232, RS485, RS422, Profibus DP, Interbus and Modbus). The distance to the TA125 could be up to 300 meters with a data rate of 38,4 kbit/s. Use bigger wire diameter for longer distances. It is possible to connect many text display to one bus (theoretical up to 256). Each one with a different text content. Additionaly the TA125 has an intrinsically safe passive alarm output. With this it is possible to connect a further alarming device. With the three digital inputs you can acknowledge a message or an alarm or you can request further information on the spot in hazardous area. The TA125 stores up to 32 kByte of messages in a internal EEprom. You can program the prestored messages with the bundled windows software ‘TEXT LINK’. There are two ways to display the prestored texts: the serial interface or applying a defined bit pattern to binary address inputs of the TI125 (option). II 2 D Ex t IIIC T70°C Db IP65 (TA125) II (2) G [Exib] IIC (Gb) (TI125) Zone 1 Zone 2 Zone 21 Zone 22 On request Specifications • TA125 Protection Material Mounting EX-limits Transmission speed Connection to TI125 Ambiant temperature TI125 Protection Material Mounting Mounting Ambiant temperature 146 II 2 G Ex ib IIC T6 Gb (TA125) IP65 aluminium, lacquered 7035 zone 1 • digital output: Ui=30V, li=160mA, Pi=0,85W • digital input: Uo=6V, lo=1mA up to 38,4 kbits/s 2 x 2 x 0,25 mm² (or bigger diameter) -20°C - +45/65°C On demand the number of digital intrinsically safe inputs can expand up to 12. (connection of a keyboard) IP40 aluminium safe area 35 mm rail acc. DIN EN 50022 -20°C - +60°C For certificates, spare parts, light intensity diagrams, etc., please consult our website: www.ysebaert.be 7 Man - machine interface 2 Message display 1 TA125 series Ordering data Interface module Option binary address input Code Description Protection Voltage TA125 display IP65 TI125.0.0.0 interface IP40 RS485/RS232/RS422 without 230VAC TI125.0.0.1 interface IP40 RS485/RS232/RS422 present 230VAC TI125.0.1.0 interface IP40 Modbus without 230VAC TI125.0.1.1 interface IP40 Modbus present 230VAC TI125.0.2.0 interface IP40 Profibus DP without 230VAC TI125.0.2.1 interface IP40 Profibus DP present 230VAC TI125.3.0.0 interface IP40 RS485/RS232/RS422 without 110VAC TI125.3.0.1 interface IP40 RS485/RS232/RS422 present 110VAC TI125.3.1.0 interface IP40 Modbus without 110VAC TI125.3.1.1 interface IP40 Modbus present 110VAC TI125.3.2.0 interface IP40 Profibus DP without 110VAC TI125.3.2.1 interface IP40 Profibus DP present 110VAC TI125.6.0.0 interface IP40 RS485/RS232/RS422 without 24VDC TI125.6.0.1 interface IP40 RS485/RS232/RS422 present 24VDC TI125.6.1.0 interface IP40 Modbus without 24VDC TI125.6.1.1 interface IP40 Modbus present 24VDC TI125.6.2.0 interface IP40 Profibus DP without 24VDC TI125.6.2.1 interface IP40 Profibus DP present 24VDC Character height Text display Viewing area 15 mm 4 x 40 characters 68 x 244 mm Dimensional sketches TA TI www.ysebaert.be ● info@ysebaert.be ● T +32(0)3 328 06 60 ● F +32(0)3 328 06 80 147 7 Man - machine interface 3 Modular Ex-PC 1 PC100 series The PC100 is the user interface of an industrial PC designed for use in zone 1. The PC is located in the safe area. There are no more intrinsically safe barriers necessary - the PC is unlimited network capable. A later update to a more powerful PC is possible at any time. The PC is connected with a video-remote control to the PC100. For the remote control usually a 4 x 2 AWG24 (CAT 5/6) cable is recommended, but alternatively a glass fibre can be used. The customer don’t have to follow the rules for intrinsically safe wiring, because the connection is not intrinsically safe: the power supply (e.g. 230VAC) of the display is connected to the integrated Ex e-terminal box. Therefore no Exi-multi power supplies are necessary. The intrinsically safe keyboard and stainless steel trackball (both IP65) are connected to the PC100 with a plug. The modules above are integrated in a graceful designed commander housing. The housing is manufactured of stainless steel with a protection class of IP65. Therefore it can be used in pharmaceutical or food production. It is also possible to integrate the PC100 modules in an existing control panel. The PC100 gives his user the degree of freedom and flexibility, he needs now and in the future. Zone 1 Zone 2 IP65 stainless steel 230VAC zone 1 Zone 21 Zone 22 On request • • • • • • Specifications Protection Material Voltage Mounting II 2 G Ex eb qb ib [ib] IIC T4 display 8,4» or 10,4» housing material: steel lacked or aluminium several mounting possibilities of commander housing optical waveguide to PC voltage 110VAC or 24VDC housing without writing desk Ordering data 148 Code Display Touch screen Front window Housing PC100.0.0.0.1.1.0 15” TFT (XGA) without anti reflection coating design housing with writing desk PC100.0.0.0.1.1.1 15” TFT (XGA) integrated touch screen anti reflection coating design housing with writing desk PC100.0.3.0.1.1.0 19” TFT (SXGA) without anti reflection coating design housing with writing desk PC100.0.3.0.1.1.1 19” TFT (SXGA) integrated touch screen anti reflection coating design housing with writing desk PC100.0.4.0.1.1.0 21” TFT (SXGA) without anti reflection coating design housing with writing desk PC100.0.4.0.1.1.1 21” TFT (SXGA) integrated touch screen anti reflection coating design housing with writing desk PC100.0.5.0.1.1.0 22” TFT (SXGA) without anti reflection coating design housing with writing desk PC100.0.5.0.1.1.1 22” TFT (SXGA) integrated touch screen anti reflection coating design housing with writing desk PC100.0.6.0.1.1.0 24” TFT (SXGA) without anti reflection coating design housing with writing desk PC100.0.6.0.1.1.1 24” TFT (SXGA) integrated touch screen anti reflection coating design housing with writing desk For certificates, spare parts, light intensity diagrams, etc., please consult our website: www.ysebaert.be 7 Man - machine interface 3 Modular Ex-PC 1 PC100 series Dimensional sketches www.ysebaert.be ● info@ysebaert.be ● T +32(0)3 328 06 60 ● F +32(0)3 328 06 80 149 7 Man - machine interface 4 Keyboard and Trackball 1 KB/TB/KI 153 series Thanks to the KI153 interface it is possible to use 2 USB devices in an EXzone. Hereby it is possible to use an intrinsically keyboard and trackball in a zone 1. Both devices are available as panel mounting aswell as completely recessed in a housing. II 2 G Ex ib IIC T4 Gb (KB153/TB153) II (2) G [Exib Gb] IIC (KI153) Zone 1 Zone 2 Zone 21 Zone 22 Specifications keyboard Connection Protection EX-limits Mounting Ambiant temperature trackball Connection Protection Service controle EX-limits Mounting Ambiant temperature interface Connection Protection Mounting Ambiant temperature USB IP65 Ui= 5,8V, li= 204mA, Pi= 0,392W, Ci= 25μF, Li= ignorent small zone 1 -20°C - +50°C USB IP65 including 2 cursor push buttons Ui= 5,8V, li= 204mA, Pi= 0,392W, Ci= 25μF, Li= ignorent small zone 1 0°C - +50°C 1 or 2 x USB (only suitable for low speed) IP40 safe area -20°C - +40°C On request • zone 22 Ordering data 150 Code Description Housing KB153.0.0 keyboard recessed No. of USB channels Language layout German KB153.0.1 keyboard recessed US KB153.1.0 keyboard surface German KB153.1.1 keyboard surface US TB153.0.0 trackball recessed TB153.1.0 trackball surface KI153.0 interface 1 KI153.1 interface 2 Diam. trackball 38 mm 38 mm For certificates, spare parts, light intensity diagrams, etc., please consult our website: www.ysebaert.be 7 Man - machine interface 4 Keyboard and Trackball 1 KB/TB/KI 153 series Dimensional sketches www.ysebaert.be ● info@ysebaert.be ● T +32(0)3 328 06 60 ● F +32(0)3 328 06 80 151 8 Cable glands and accessories 1 Glands ........................................................................................................ 155 1 2 3 4 5 6 7 2 Exd / Exe metal - single compression: PA ...................................... 155 Exd / Exe metal - double compression: PAP .................................. 158 Exd / Exe metal - double compression for lead cable: PPAP ......... 162 Ex barrier metal - single compression: PA/B................................... 166 Ex barrier metal - double compression: PAP/B ............................... 170 Ex barrier metal - double compression for lead cable: PPAP/B ...... 174 Exe-plastic / metric thread .............................................................. 178 Plugs .......................................................................................................... 180 1 Exd brass ........................................................................................ 180 2 Exe brass ........................................................................................ 181 3 Exe plastic....................................................................................... 182 3 Reducers and adapters .............................................................................. 183 1 Exd / Exe brass ............................................................................... 183 2 Exe plastic....................................................................................... 185 4 Accessories ................................................................................................ 187 1 Earth tags brass .............................................................................. 187 2 Lock nuts......................................................................................... 188 3 Gaskets plastic................................................................................ 189 5 Special passing troughs ............................................................................. 190 1 Drainage valve ................................................................................ 190 2 Coupling for air/gas ......................................................................... 191 www.ysebaert.be ● info@ysebaert.be ● T +32(0)3 328 06 60 ● F +32(0)3 328 06 80 153 8 Cable glands and accessories 1 Glands 1 Exd / Exe metal - single compression: PA Suited for armoured and non-armoured cables.Sealing on outer sheath of the cable.Mechanical protection IP66 in all positions. Sizes 1 and 2 available in reduced version. Specifications Material cable gland Protection Seal Thread brass OT 58 IP66 neoprene NPT in accordance with ANSI B2.1 Metric - pitch 1,5 -20°C - +80°C Ambiant temperature II 2 G Ex d IIC / Ex e II II 2 D Ex tD A21 IP66 Zone 1 Zone 2 Zone 21 Zone 22 INERIS03ATEX0028 On request • • • • • copper-free aluminium (type ../A) stainless steel 316 (type ../S6) stainless steel 304 (type ../S4) nickel-plated brass (type ../N) ambiant temperature -40°C Ordering data Product code Thread Cable diameter Min Max PA1R07M M20 4 7 PA1R07N 1/2”NPT 4 7 PA1R09M M20 7 9,5 PA1R09N 1/2”NPT 7 9,5 PA1R12M M20 9 12 PA1R12N 1/2”NPT 9 12 PA2R12M M25 9 12 PA2R12N 3/4”NPT 9 12 PA2R14M M25 12 14,5 PA2R14N 3/4”NPT 12 14,5 PA2R17M M25 14 17 PA2R17N 3/4”NPT 14 17 PA3.17M M32 14 17 PA3.17N 1”NPT 14 17 PA3.20M M32 17 20 PA3.20N 1”NPT 17 20 PA3.23M M32 20 23 PA3.23N 1”NPT 20 23 PA4.23M M40 20 23 PA4.23N 1 1/4”NPT 20 23 PA4.26M M40 23 26 PA4.26N 1 1/4”NPT 23 26 PA4.29M M40 26 29 PA4.29N 1 1/4”NPT 26 29 PA4.32M M40 29 32 PA4.32N 1 1/4”NPT 29 32 PA4.35M M40 32 35 PA4.35N 1 1/4”NPT 32 35 PA5.23M M50 20 23 PA5.23N 1 1/2”NPT 20 23 PA5.26M M50 23 26 PA5.26N 1 1/2”NPT 23 26 PA5.29M M50 26 29 PA5.29N 1 1/2”NPT 26 29 PA5.32M M50 29 32 PA5.32N 1 1/2”NPT 29 32 www.ysebaert.be ● info@ysebaert.be ● T +32(0)3 328 06 60 ● F +32(0)3 328 06 80 155 8 Cable glands and accessories 1 Glands 1 Exd / Exe metal - single compression: PA Product code Thread Cable diameter Min Max PA5.35M M50 32 35,5 PA5.35N 1 1/2”NPT 32 35,5 PA6.35M M63 32 35,5 PA6.35N 2”NPT 32 35,5 PA6.39M M63 36 39 PA6.39N 2”NPT 36 39 PA6.42M M63 39 42 PA6.42N 2”NPT 39 42 PA6.47M M63 44 47 PA6.47N 2”NPT 44 47 PA7.47M M75 44 47 PA7.47N 2 1/2”NPT 44 47 PA7.52M M75 50 52 PA7.52N 2 1/2”NPT 50 52 PA8.57M M85 52 57 PA8.57N 3”NPT 52 57 PA8.61M M85 57 61 PA8.61N 3”NPT 57 61 PA8A.65M M85 61 65 PA8A.65N 3”NPT 61 65 PA8A.68M M85 65 68 PA8A.68N 3”NPT 65 68 PA10.73M M110 68 73 PA10.73N 4”NPT 68 73 PA10.78M M110 74 78 PA10.78N 4”NPT 74 78 Dimensional sketches PA3-10 PA3-10 156 Product code Dimensions D F G H PA1R07M 17 50 27 31 PA1R09M 17 50 27 31 PA1R12M 17 50 27 31 PA2R12M 17 50 32 37 PA2R14M 17 50 32 37 PA2R17M 17 50 32 37 PA3.17M 21 64 43 46 PA3.20M 21 64 43 46 PA3.23M 21 64 43 46 PA4.23M 21 64 59 63 PA4.26M 21 64 59 63 PA4.29M 21 64 59 63 PA4.32M 21 64 59 63 PA4.35M 21 64 59 63 PA5.23M 21 64 59 63 PA5.26M 21 64 59 63 PA5.29M 21 64 59 63 PA5.32M 21 64 59 63 PA5.35M 21 64 59 63 PA6.35M 23 69 68 74 PA6.39M 23 69 68 74 PA6.42M 23 69 68 74 PA6.47M 23 69 68 74 For certificates, spare parts, light intensity diagrams, etc., please consult our website: www.ysebaert.be 8 Cable glands and accessories 1 Glands 1 Exd / Exe metal - single compression: PA Product code Dimensions D F G H PA7.47M 26 71 82 88 PA7.52M 26 71 82 88 PA8.57M 26 88 100 118 PA8.61M 26 88 100 118 PA8A.65M 26 88 100 118 PA8A.68M 26 88 100 118 PA10.73M 28 94 PA10.78M 28 94 PA1R07N 17 50 27 31 PA1R09N 17 50 27 31 PA1R12N 17 50 27 31 PA2R12N 17 50 32 37 PA2R14N 17 50 32 37 PA2R17N 17 50 32 37 PA3.17N 21 64 43 46 PA3.20N 21 64 43 46 PA3.23N 21 64 43 46 PA4.23N 21 64 59 63 PA4.26N 21 64 59 63 PA4.29N 21 64 59 63 PA4.32N 21 64 59 63 PA4.35N 21 64 59 63 PA5.23N 21 64 59 63 PA5.26N 21 64 59 63 PA5.29N 21 64 59 63 PA5.32N 21 64 59 63 PA5.35N 21 64 59 63 PA6.35N 23 69 68 74 PA6.39N 23 69 68 74 PA6.42N 23 69 68 74 PA6.47N 23 69 68 74 PA7.47N 26 71 82 88 PA7.52N 26 71 82 88 PA8.57N 26 88 100 118 PA8.61N 26 88 100 118 PA8A.65N 26 88 100 118 PA8A.68N 26 88 100 118 PA10.73N 28 94 128 PA10.78N 28 94 128 128 128 www.ysebaert.be ● info@ysebaert.be ● T +32(0)3 328 06 60 ● F +32(0)3 328 06 80 157 8 Cable glands and accessories 1 Glands 2 Exd / Exe metal - double compression: PAP Suited for armoured cables. Sealing on inner and outer sheaths of the cable. Compression of the armouring. Mechanical protection IP66 in all positions. Sizes 1 and 2 available in reduced version. Zone 1 Specifications Zone 2 Material cable gland Protection Seal Thread Ambiant temperature II 2 G Ex d IIC / Ex e II II 2 D Ex tD A21 IP66 brass OT 58 IP66 neoprene NPT in accordance with ANSI B2.1 Metric - pitch 1,5 -20°C - +80°C Zone 21 Zone 22 INERIS03ATEX0028 On request • • • • • copper-free aluminium (type ../A) stainless steel 316 (type ../S6) stainless steel 304 (type ../S4) nickel-plated brass (type ../N) ambiant temperature -40°C Ordering data Product Code 158 Thread Cable diameter A Min Max B Min Max 13 PAP1R0713M M20 4 7 9 PAP1R0713N 1/2”NPT 4 7 9 13 PAP1R0718M M20 4 7 13 18 PAP1R0718N 1/2”NPT 4 7 13 18 PAP1R0913M M20 7 9,5 9 13 PAP1R0913N 1/2”NPT 7 9,5 9 13 PAP1R0918M M20 7 9,5 13 18 PAP1R0918N 1/2”NPT 7 9,5 13 18 PAP1R1213M M20 9 12 9 13 PAP1R1213N 1/2”NPT 9 12 9 13 PAP1R1218M M20 9 12 13 18 PAP1R1218N 1/2”NPT 9 12 13 18 PAP2R1219M M25 9 12 15 19 PAP2R1219N 3/4”NPT 9 12 15 19 PAP2R1223M M25 9 12 18 23 PAP2R1223N 3/4”NPT 9 12 18 23 PAP2R1419M M25 12 14,5 15 19 PAP2R1419N 3/4”NPT 12 14,5 15 19 PAP2R1423M M25 12 14,5 18 23 PAP2R1423N 3/4”NPT 12 14,5 18 23 PAP2R1719M M25 14 17 15 19 PAP2R1719N 3/4”NPT 14 17 15 19 PAP2R1723M M25 14 17 18 23 PAP2R1723N 3/4”NPT 14 17 18 23 PAP3.1723M M32 14 17 20 23 PAP3.1723N 1”NPT 14 17 20 23 PAP3.1726M M32 14 17 23 26 PAP3.1726N 1”NPT 14 17 23 26 PAP3.1729M M32 14 17 24 29 PAP3.1729N 1”NPT 14 17 24 29 PAP3.2023M M32 17 20 20 23 PAP3.2023N 1”NPT 17 20 20 23 PAP3.2026M M32 17 20 23 26 PAP3.2026N 1”NPT 17 20 23 26 PAP3.2029M M32 17 20 24 29 PAP3.2029N 1”NPT 17 20 24 29 For certificates, spare parts, light intensity diagrams, etc., please consult our website: www.ysebaert.be 8 Cable glands and accessories 1 Glands 2 Exd / Exe metal - double compression: PAP Product Code Thread Cable diameter A Min Max B Min Max PAP3.2323M M32 20 23 20 23 PAP3.2323N 1”NPT 20 23 20 23 PAP3.2326M M32 20 23 23 26 PAP3.2326N 1”NPT 20 23 23 26 PAP3.2329M M32 20 23 24 29 PAP3.2329N 1”NPT 20 23 24 29 PAP4.2335M M40 20 23 30 35 PAP4.2335N 1 1/4”NPT 20 23 30 35 PAP4.2635M M40 23 26 30 35 PAP4.2635N 1 1/4”NPT 23 26 30 35 PAP4.2935M M40 26 29 30 35 PAP4.2935N 1 1/4”NPT 26 29 30 35 PAP4.3241M M40 29 32 36 41 PAP4.3241N 1 1/4”NPT 29 32 36 41 PAP4.3541M M40 32 35,5 36 41 PAP4.3541N 1 1/4”NPT 32 35,5 36 41 PAP5.2335M M50 20 23 30 35 PAP5.2335N 1 1/2”NPT 20 23 30 35 PAP5.2635M M50 23 26 30 35 PAP5.2635N 1 1/2”NPT 23 26 30 35 PAP5.2935M M50 26 29 30 35 PAP5.2935N 1 1/2”NPT 26 29 30 35 PAP5.3241M M50 29 32 36 41 PAP5.3241N 1 1/2”NPT 29 32 36 41 PAP5.3541M M50 32 35,5 36 41 PAP5.3541N 1 1/2”NPT 32 35,5 36 41 PAP6.3547M M63 32 35,5 42 47 PAP6.3547N 2”NPT 32 35,5 42 47 PAP6.3947M M63 36 39 42 47 PAP6.3947N 2”NPT 36 39 42 47 PAP6.4250M M63 39 42 46 50 PAP6.4250N 2”NPT 39 42 46 50 PAP6.4255M M63 39 42 50 55 PAP6.4255N 2”NPT 39 42 50 55 PAP6.4755M M63 44 47 50 55 PAP6.4755N 2”NPT 44 47 50 55 PAP7.4759M M75 44 47 55 59 PAP7.4759N 2 1/2”NPT 44 47 55 59 PAP7.5259M M75 50 52 55 59 PAP7.5259N 2 1/2”NPT 50 52 55 59 PAP8.5770M M85 52 57 65 70 PAP8.5770N 3”NPT 52 57 65 70 PAP8.6170M M85 57 61 65 70 PAP8.6170N 3”NPT 57 61 65 70 PAP8A.6578M M85 61 65 70 78 PAP8A.6578N 3”NPT 61 65 70 78 PAP8A.6878M M85 65 68 70 78 PAP8A.6878N 3”NPT 65 68 70 78 PAP10.7385M M110 68 73 78 85 PAP10.7385N 4”NPT 68 73 78 85 PAP10.7892M M110 74 78 85 92 PAP10.7892N 4”NPT 74 78 85 92 www.ysebaert.be ● info@ysebaert.be ● T +32(0)3 328 06 60 ● F +32(0)3 328 06 80 159 8 Cable glands and accessories 1 Glands 2 Exd / Exe metal - double compression: PAP Dimensional sketches PAP3-10 PAP1R-2R 160 Product code Dimensions D F G H PAP1R0713M 17 62 27 31 PAP1R0713N 17 62 27 31 PAP1R0718M 17 62 27 31 PAP1R0718N 17 62 27 31 PAP1R0913M 17 62 27 31 PAP1R0913N 17 62 27 31 PAP1R0918M 17 62 27 31 PAP1R0918N 17 62 27 31 PAP1R1213M 17 62 27 31 PAP1R1213N 17 62 27 31 PAP1R1218M 17 62 27 31 PAP1R1218N 17 62 27 31 PAP2R1219M 17 62 32 37 PAP2R1219N 17 62 32 37 PAP2R1223M 17 62 32 37 PAP2R1223N 17 62 32 37 PAP2R1419M 17 62 32 37 PAP2R1419N 17 62 32 37 PAP2R1423M 17 62 32 37 PAP2R1423N 17 62 32 37 PAP2R1719M 17 62 32 37 PAP2R1719N 17 62 32 37 PAP2R1723M 17 62 32 37 PAP2R1723N 17 62 32 37 PAP3.1723M 21 88 43 46 PAP3.1723N 21 88 43 46 PAP3.1726M 21 88 43 46 PAP3.1726N 21 88 43 46 PAP3.1729M 21 88 43 46 PAP3.1729N 21 88 43 46 PAP3.2023M 21 88 43 46 PAP3.2023N 21 88 43 46 PAP3.2026M 21 88 43 46 PAP3.2026N 21 88 43 46 PAP3.2029M 21 88 43 46 PAP3.2029N 21 88 43 46 PAP3.2323M 21 88 43 46 PAP3.2323N 21 88 43 46 PAP3.2326M 21 88 43 46 PAP3.2326N 21 88 43 46 PAP3.2329M 21 88 43 46 PAP3.2329N 21 88 43 46 PAP4.2335M 21 88 59 63 PAP4.2335N 21 88 59 63 PAP4.2635M 21 88 59 63 PAP4.2635N 21 88 59 63 PAP4.2935M 21 88 59 63 PAP4.2935N 21 88 59 63 PAP4.3241M 21 88 59 63 PAP4.3241N 21 88 59 63 PAP4.3541M 21 88 59 63 PAP4.3541N 21 88 59 63 For certificates, spare parts, light intensity diagrams, etc., please consult our website: www.ysebaert.be 8 Cable glands and accessories 1 Glands 2 Exd / Exe metal - double compression: PAP Product code Dimensions D F G H PAP5.2335M 21 88 59 63 PAP5.2335N 21 88 59 63 PAP5.2635M 21 88 59 63 PAP5.2635N 21 88 59 63 PAP5.2935M 21 88 59 63 PAP5.2935N 21 88 59 63 PAP5.3241M 21 88 59 63 PAP5.3241N 21 88 59 63 PAP5.3541M 21 88 59 63 PAP5.3541N 21 88 59 63 PAP6.3547M 23 92 68 74 PAP6.3547N 23 92 68 74 PAP6.3947M 23 92 68 74 PAP6.3947N 23 92 68 74 PAP6.4250M 23 92 68 74 PAP6.4250N 23 92 68 74 PAP6.4255M 23 92 68 74 PAP6.4255N 23 92 68 74 PAP6.4755M 23 92 68 74 PAP6.4755N 23 92 68 74 PAP7.4759M 26 92 82 88 PAP7.4759N 26 92 82 88 PAP7.5259M 26 92 82 88 PAP7.5259N 26 92 82 88 PAP8.5770M 26 115 100 118 PAP8.5770N 26 115 100 118 PAP8.6170M 26 115 100 118 PAP8.6170N 26 115 100 118 PAP8A.6578M 26 115 100 118 PAP8A.6578N 26 115 100 118 PAP8A.6878M 26 115 100 118 PAP8A.6878N 26 115 100 118 PAP10.7385M 28 117 128 PAP10.7385N 28 117 128 PAP10.7892M 28 117 128 PAP10.7892N 28 117 128 www.ysebaert.be ● info@ysebaert.be ● T +32(0)3 328 06 60 ● F +32(0)3 328 06 80 161 8 Cable glands and accessories 1 Glands 3 Exd / Exe metal - double compression for lead cable: PPAP Suited for armoured cables with lead sheaths. Sealing on inner and outer sheath of the cable. Compression of the cable’s armouring. With lead plate for earthing continuousity. Mechanical protection IP66 in all positions. Zone 1 Specifications Zone 2 Material cable gland Protection Seal Thread Ambiant temperature II 2 G Ex d IIC / Ex e II II 2 D Ex tD A21 IP66 brass OT 58 IP66 neoprene NPT in accordance with ANSI B2.1Metric pitch 1,5 -20°C - +80°C Zone 21 Zone 22 INERIS03ATEX0028 On request • • • • • copper-free aluminium (type ../A) stainless steel 316 (type ../S6) stainless steel 304 (type ../S4) nickel-plated brass (type ../N) ambiant temperature -40°C Ordering data Product code 162 Thread Cable diameter A Min Max B Min Max 13 PPAP1R0713M M20 4 7 9 PPAP1R0713N 1/2”NPT 4 7 9 13 PPAP1R0718M M20 4 7 13 18 PPAP1R0718N 1/2”NPT 4 7 13 18 PPAP1R0913M M20 7 9,5 9 13 PPAP1R0913N 1/2”NPT 7 9,5 9 13 PPAP1R0918M M20 7 9,5 13 18 PPAP1R0918N 1/2”NPT 7 9,5 13 18 PPAP1R1213M M20 9 12 9 13 PPAP1R1213N 1/2”NPT 9 12 9 13 PPAP1R1218M M20 9 12 13 18 PPAP1R1218N 1/2”NPT 9 12 13 18 PPAP2R1219M M25 9 12 15 19 PPAP2R1219N 3/4”NPT 9 12 15 19 PPAP2R1223M M25 9 12 18 23 PPAP2R1223N 3/4”NPT 9 12 18 23 PPAP2R1419M M25 12 14,5 15 19 PPAP2R1419N 3/4”NPT 12 14,5 15 19 PPAP2R1423M M25 12 14,5 18 23 PPAP2R1423N 3/4”NPT 12 14,5 18 23 PPAP2R1719M M25 14 17 15 19 PPAP2R1719N 3/4”NPT 14 17 15 19 PPAP2R1723M M25 14 17 18 23 PPAP2R1723N 3/4”NPT 14 17 18 23 PPAP3.1723M M32 14 17 20 23 PPAP3.1723N 1”NPT 14 17 20 23 PPAP3.1726M M32 14 17 23 26 PPAP3.1726N 1”NPT 14 17 23 26 PPAP3.1729M M32 14 17 24 29 PPAP3.1729N 1”NPT 14 17 24 29 PPAP3.2023M M32 17 20 20 23 PPAP3.2023N 1”NPT 17 20 20 23 PPAP3.2026M M32 17 20 23 26 PPAP3.2026N 1”NPT 17 20 23 26 PPAP3.2029M M32 17 20 24 29 PPAP3.2029N 1”NPT 17 20 24 29 For certificates, spare parts, light intensity diagrams, etc., please consult our website: www.ysebaert.be 8 Cable glands and accessories 1 Glands 3 Exd / Exe metal - double compression for lead cable: PPAP Product code Thread Cable diameter A Min Max B Min Max PPAP3.2323M M32 20 23 20 23 PPAP3.2323N 1”NPT 20 23 20 23 PPAP3.2326M M32 20 23 23 26 PPAP3.2326N 1”NPT 20 23 23 26 PPAP3.2329M M32 20 23 24 29 PPAP3.2329N 1”NPT 20 23 24 29 PPAP4.2335M M40 20 23 30 35 PPAP4.2335N 1 1/4”NPT 20 23 30 35 PPAP4.2635M M40 23 26 30 35 PPAP4.2635N 1 1/4”NPT 23 26 30 35 PPAP4.2935M M40 26 29 30 35 PPAP4.2935N 1 1/4”NPT 26 29 30 35 PPAP4.3241M M40 29 32 36 41 PPAP4.3241N 1 1/4”NPT 29 32 36 41 PPAP4.3541M M40 32 35,5 36 41 PPAP4.3541N 1 1/4”NPT 32 35,5 36 41 PPAP5.2335M M50 20 23 30 35 PPAP5.2335N 1 1/2”NPT 20 23 30 35 PPAP5.2635M M50 23 26 30 35 PPAP5.2635N 1 1/2”NPT 23 26 30 35 PPAP5.2935M M50 26 29 30 35 PPAP5.2935N 1 1/2”NPT 26 29 30 35 PPAP5.3241M M50 29 32 36 41 PPAP5.3241N 1 1/2”NPT 29 32 36 41 PPAP5.3541M M50 32 35,5 36 41 PPAP5.3541N 1 1/2”NPT 32 35,5 36 41 PPAP6.3547M M63 32 35,5 42 47 PPAP6.3547N 2”NPT 32 35,5 42 47 PPAP6.3947M M63 36 39 42 47 PPAP6.3947N 2”NPT 36 39 42 47 PPAP6.4250M M63 39 42 46 50 PPAP6.4250N 2”NPT 39 42 46 50 PPAP6.4255M M63 39 42 50 55 PPAP6.4255N 2”NPT 39 42 50 55 PPAP6.4755M M63 44 47 50 55 PPAP6.4755N 2”NPT 44 47 50 55 PPAP7.4759M M75 44 47 55 59 PPAP7.4759N 2 1/2”NPT 44 47 55 59 PPAP7.5259M M75 50 52 55 59 PPAP7.5259N 2 1/2”NPT 50 52 55 59 PPAP8.5770M M85 52 57 65 70 PPAP8.5770N 3”NPT 52 57 65 70 PPAP8.6170M M85 57 61 65 70 PPAP8.6170N 3”NPT 57 61 65 70 PPAP8A.6578M M85 61 65 70 78 PPAP8A.6578N 3”NPT 61 65 70 78 PPAP8A.6878M M85 65 68 70 78 PPAP8A.6878N 3”NPT 65 68 70 78 PPAP10.7385M M110 68 73 78 85 PPAP10.7385N 4”NPT 68 73 78 85 PPAP10.7892M M110 74 78 85 92 PPAP10.7892N 4”NPT 74 78 85 92 www.ysebaert.be ● info@ysebaert.be ● T +32(0)3 328 06 60 ● F +32(0)3 328 06 80 163 8 Cable glands and accessories 1 Glands 3 Exd / Exe metal - double compression for lead cable: PPAP Dimensional sketches PPAP3-10 PPAP1R-2R 164 Product code Dimensions D F G H PPAP1R0713M 17 62 27 31 PPAP1R0713N 17 62 27 31 PPAP1R0718M 17 62 27 31 PPAP1R0718N 17 62 27 31 PPAP1R0913M 17 62 27 31 PPAP1R0913N 17 62 27 31 PPAP1R0918M 17 62 27 31 PPAP1R0918N 17 62 27 31 PPAP1R1213M 17 62 27 31 PPAP1R1213N 17 62 27 31 PPAP1R1218M 17 62 27 31 PPAP1R1218N 17 62 27 31 PPAP2R1219M 17 62 32 37 PPAP2R1219N 17 62 32 37 PPAP2R1223M 17 62 32 37 PPAP2R1223N 17 62 32 37 PPAP2R1419M 17 62 32 37 PPAP2R1419N 17 62 32 37 PPAP2R1423M 17 62 32 37 PPAP2R1423N 17 62 32 37 PPAP2R1719M 17 62 32 37 PPAP2R1719N 17 62 32 37 PPAP2R1723M 17 62 32 37 PPAP2R1723N 17 62 32 37 PPAP3.1723M 21 88 43 46 PPAP3.1723N 21 88 43 46 PPAP3.1726M 21 88 43 46 PPAP3.1726N 21 88 43 46 PPAP3.1729M 21 88 43 46 PPAP3.1729N 21 88 43 46 PPAP3.2023M 21 88 43 46 PPAP3.2023N 21 88 43 46 PPAP3.2026M 21 88 43 46 PPAP3.2026N 21 88 43 46 PPAP3.2029M 21 88 43 46 PPAP3.2029N 21 88 43 46 PPAP3.2323M 21 88 43 46 PPAP3.2323N 21 88 43 46 PPAP3.2326M 21 88 43 46 PPAP3.2326N 21 88 43 46 PPAP3.2329M 21 88 43 46 PPAP3.2329N 21 88 43 46 PPAP4.2335M 21 88 59 63 PPAP4.2335N 21 88 59 63 PPAP4.2635M 21 88 59 63 PPAP4.2635N 21 88 59 63 PPAP4.2935M 21 88 59 63 PPAP4.2935N 21 88 59 63 PPAP4.3241M 21 88 59 63 PPAP4.3241N 21 88 59 63 PPAP4.3541M 21 88 59 63 PPAP4.3541N 21 88 59 63 For certificates, spare parts, light intensity diagrams, etc., please consult our website: www.ysebaert.be 8 Cable glands and accessories 1 Glands 3 Exd / Exe metal - double compression for lead cable: PPAP Product code Dimensions D F G H PPAP5.2335M 21 88 59 63 PPAP5.2335N 21 88 59 63 PPAP5.2635M 21 88 59 63 PPAP5.2635N 21 88 59 63 PPAP5.2935M 21 88 59 63 PPAP5.2935N 21 88 59 63 PPAP5.3241M 21 88 59 63 PPAP5.3241N 21 88 59 63 PPAP5.3541M 21 88 59 63 PPAP5.3541N 21 88 59 63 PPAP6.3547M 23 92 68 74 PPAP6.3547N 23 92 68 74 PPAP6.3947M 23 92 68 74 PPAP6.3947N 23 92 68 74 PPAP6.4250M 23 92 68 74 PPAP6.4250N 23 92 68 74 PPAP6.4255M 23 92 68 74 PPAP6.4255N 23 92 68 74 PPAP6.4755M 23 92 68 74 PPAP6.4755N 23 92 68 74 PPAP7.4759M 26 92 82 88 PPAP7.4759N 26 92 82 88 PPAP7.5259M 26 92 82 88 PPAP7.5259N 26 92 82 88 PPAP8.5770M 26 115 100 118 PPAP8.5770N 26 115 100 118 PPAP8.6170M 26 115 100 118 PPAP8.6170N 26 115 100 118 PPAP8A.6578M 26 115 100 118 PPAP8A.6578N 26 115 100 118 PPAP8A.6878M 26 115 100 118 PPAP8A.6878N 26 115 100 118 PPAP10.7385M 28 117 128 PPAP10.7385N 28 117 128 PPAP10.7892M 28 117 128 PPAP10.7892N 28 117 128 www.ysebaert.be ● info@ysebaert.be ● T +32(0)3 328 06 60 ● F +32(0)3 328 06 80 165 8 Cable glands and accessories 1 Glands 4 Ex barrier metal - single compression: PA/B Our barrier glands are composed identically to the classic PA-glands. However an extra metal ring is added in the body which will be filled with a compound. Whether you should use a barrier gland or not can be deducted from the flowchart below. Suited for non-armoured cables. Sealing on outer sheath of the cable. Mechanical protection IP66 in all positions. Sizes 1 and 2 available in reduced version. II 2 G Exd IIC / Exe II II 2 D ExtD A21 IP66 Zone 1 Zone 2 Zone 21 Zone 22 INERIS03ATEX0028 Specifications Material cable gland Protection Seal Thread Ambiant temperature 166 brass OT 58 IP66 neoprene NPT in accordance with ANSI B2.1 Metric - pitch 1,5 -20°C - +80°C On request • • • • • copper-free aluminium (type ../A) stainless steel 316 (type ../S6) stainless steel 304 (type ../S4) nickel-plated brass (type ../N) ambiant temperature -40°C For certificates, spare parts, light intensity diagrams, etc., please consult our website: www.ysebaert.be 8 Cable glands and accessories 1 Glands 4 Ex barrier metal - single compression: PA/B Ordering data Product code Thread Cable diameter Min Max PA1R07M/B M20 4 7 PA1R07N/B 1/2”NPT 4 7 PA1R09M/B M20 7 9,5 PA1R09N/B 1/2”NPT 7 9,5 PA1R12M/B M20 9 12 PA1R12N/B 1/2”NPT 9 12 PA2R12M/B M25 9 12 PA2R12N/B 3/4”NPT 9 12 PA2R14M/B M25 12 14,5 PA2R14N/B 3/4”NPT 12 14,5 PA2R17M/B M25 14 17 PA2R17N/B 3/4”NPT 14 17 PA3.17M/B M32 14 17 PA3.17N/B 1”NPT 14 17 PA3.20M/B M32 17 20 PA3.20N/B 1”NPT 17 20 PA3.23M/B M32 20 23 PA3.23N/B 1”NPT 20 23 PA4.23M/B M40 20 23 PA4.23N/B 1 1/4”NPT 20 23 PA4.26M/B M40 23 26 PA4.26N/B 1 1/4”NPT 23 26 PA4.29M/B M40 26 29 PA4.29N/B 1 1/4”NPT 26 29 PA4.32M/B M40 29 32 PA4.32N/B 1 1/4”NPT 29 32 PA4.35M/B M40 32 35 PA4.35N/B 1 1/4”NPT 32 35 PA5.23M/B M50 20 23 PA5.23N/B 1 1/2”NPT 20 23 PA5.26M/B M50 23 26 PA5.26N/B 1 1/2”NPT 23 26 PA5.29M/B M50 26 29 PA5.29N/B 1 1/2”NPT 26 29 PA5.32M/B M50 29 32 PA5.32N/B 1 1/2”NPT 29 32 PA5.35M/B M50 32 35,5 PA5.35N/B 1 1/2”NPT 32 35,5 PA6.35M/B M63 32 35,5 PA6.35N/B 2”NPT 32 35,5 PA6.39M/B M63 36 39 PA6.39N/B 2”NPT 36 39 PA6.42M/B M63 39 42 PA6.42N/B 2”NPT 39 42 PA6.47M/B M63 44 47 PA6.47N/B 2”NPT 44 47 PA7.47M/B M75 44 47 PA7.47N/B 2 1/2”NPT 44 47 PA7.52M/B M75 50 52 PA7.52N/B 2 1/2”NPT 50 52 PA8.57M/B M85 52 57 PA8.57N/B 3”NPT 52 57 PA8.61M/B M85 57 61 PA8.61N/B 3”NPT 57 61 PA8A.65M/B M85 61 65 PA8A.65N/B 3”NPT 61 65 PA8A.68M/B M85 65 68 PA8A.68N/B 3”NPT 65 68 PA10.73M/B M110 68 73 PA10.73N/B 4”NPT 68 73 PA10.78M/B M110 74 78 PA10.78N/B 4”NPT 74 78 www.ysebaert.be ● info@ysebaert.be ● T +32(0)3 328 06 60 ● F +32(0)3 328 06 80 167 8 Cable glands and accessories 1 Glands 4 Ex barrier metal - single compression: PA/B Dimensional sketches PA3-10 PA3-10 168 Product code Dimensions D F G H PA1R07M/B 17 50 27 31 PA1R09M/B 17 50 27 31 PA1R12M/B 17 50 27 31 PA2R12M/B 17 50 32 37 PA2R14M/B 17 50 32 37 PA2R17M/B 17 50 32 37 PA3.17M/B 21 64 43 46 PA3.20M/B 21 64 43 46 PA3.23M/B 21 64 43 46 PA4.23M/B 21 64 59 63 PA4.26M/B 21 64 59 63 PA4.29M/B 21 64 59 63 PA4.32M/B 21 64 59 63 PA4.35M/B 21 64 59 63 PA5.23M/B 21 64 59 63 PA5.26M/B 21 64 59 63 PA5.29M/B 21 64 59 63 PA5.32M/B 21 64 59 63 PA5.35M/B 21 64 59 63 PA6.35M/B 23 69 68 74 PA6.39M/B 23 69 68 74 PA6.42M/B 23 69 68 74 PA6.47M/B 23 69 68 74 PA7.47M/B 26 71 82 88 PA7.52M/B 26 71 82 88 PA8.57M/B 26 88 100 118 PA8.61M/B 26 88 100 118 PA8A.65M/B 26 88 100 118 PA8A.68M/B 26 88 100 118 PA10.73M/B 28 94 PA10.78M/B 28 94 PA1R07N/B 17 50 27 31 PA1R09N/B 17 50 27 31 PA1R12N/B 17 50 27 31 PA2R12N/B 17 50 32 37 PA2R14N/B 17 50 32 37 PA2R17N/B 17 50 32 37 PA3.17N/B 21 64 43 46 PA3.20N/B 21 64 43 46 PA3.23N/B 21 64 43 46 PA4.23N/B 21 64 59 63 PA4.26N/B 21 64 59 63 PA4.29N/B 21 64 59 63 PA4.32N/B 21 64 59 63 PA4.35N/B 21 64 59 63 PA5.23N/B 21 64 59 63 PA5.26N/B 21 64 59 63 PA5.29N/B 21 64 59 63 PA5.32N/B 21 64 59 63 PA5.35N/B 21 64 59 63 PA6.35N/B 23 69 68 74 PA6.39N/B 23 69 68 74 128 128 For certificates, spare parts, light intensity diagrams, etc., please consult our website: www.ysebaert.be 8 Cable glands and accessories 1 Glands 4 Ex barrier metal - single compression: PA/B Product code Dimensions D F G H PA6.42N/B 23 69 68 74 PA6.47N/B 23 69 68 74 PA7.47N/B 26 71 82 88 PA7.52N/B 26 71 82 88 PA8.57N/B 26 88 100 118 PA8.61N/B 26 88 100 118 PA8A.65N/B 26 88 100 118 PA8A.68N/B 26 88 100 118 PA10.73N/B 28 94 128 PA10.78N/B 28 94 128 Compound Code Description PAP-COMPOUND-1 kit 100g, consisting of: bottle A, bottle B, gloves, syringe, stirring rod, mixing jar PAP-COMPOUND-3 kit 300g, consisting of: bottle A, bottle B, gloves, 3 syringes, 3 stirring rods, 3 mixing jars www.ysebaert.be ● info@ysebaert.be ● T +32(0)3 328 06 60 ● F +32(0)3 328 06 80 169 8 Cable glands and accessories 1 Glands 5 Ex barrier metal - double compression: PAP/B Our barrier glands are composed identically to the classic PAP-glands. However an extra metal ring is added in the body which will be filled with a II 2 G Exd IIC / Exe II II 2 D ExtD A21 IP66 compound. Whether you should use a barrier gland or not can be deducted from the flowchart below. Suited for armoured cables. Sealing on inner and outer sheaths of the cable. Compression of the armouring. Mechanical protection IP66 in all positions. Sizes 1 and 2 available in reduced version. Zone 1 Zone 2 Zone 21 Zone 22 INERIS03ATEX0028 Specifications Material cable gland Protection Seal Thread Ambiant temperature brass OT 58 IP66 neoprene NPT in accordance with ANSI B2.1 Metric - pitch 1,5 -20°C - +80°C On request • • • • • copper-free aluminium (type ../A) stainless steel 316 (type ../S6) stainless steel 304 (type ../S4) nickel-plated brass (type ../N) ambiant temperature -40°C Ordering data Product Code 170 Thread Cable diameter A Min Max B Min Max 13 PAP1R0713M/B M20 4 7 9 PAP1R0713N/B 1/2”NPT 4 7 9 13 PAP1R0718M/B M20 4 7 13 18 PAP1R0718N/B 1/2”NPT 4 7 13 18 PAP1R0913M/B M20 7 9,5 9 13 PAP1R0913N/B 1/2”NPT 7 9,5 9 13 PAP1R0918M/B M20 7 9,5 13 18 PAP1R0918N/B 1/2”NPT 7 9,5 13 18 PAP1R1213M/B M20 9 12 9 13 PAP1R1213N/B 1/2”NPT 9 12 9 13 PAP1R1218M/B M20 9 12 13 18 PAP1R1218N/B 1/2”NPT 9 12 13 18 For certificates, spare parts, light intensity diagrams, etc., please consult our website: www.ysebaert.be 8 Cable glands and accessories 1 Glands 5 Ex barrier metal - double compression: PAP/B Product Code Thread Cable diameter A Min Max B Min Max 19 PAP2R1219M/B M25 9 12 15 PAP2R1219N/B 3/4”NPT 9 12 15 19 PAP2R1223M/B M25 9 12 18 23 PAP2R1223N/B 3/4”NPT 9 12 18 23 PAP2R1419M/B M25 12 14,5 15 19 PAP2R1419N/B 3/4”NPT 12 14,5 15 19 PAP2R1423M/B M25 12 14,5 18 23 PAP2R1423N/B 3/4”NPT 12 14,5 18 23 PAP2R1719M/B M25 14 17 15 19 PAP2R1719N/B 3/4”NPT 14 17 15 19 PAP2R1723M/B M25 14 17 18 23 PAP2R1723N/B 3/4”NPT 14 17 18 23 PAP3.1723M/B M32 14 17 20 23 PAP3.1723N/B 1”NPT 14 17 20 23 PAP3.1726M/B M32 14 17 23 26 PAP3.1726N/B 1”NPT 14 17 23 26 PAP3.1729M/B M32 14 17 24 29 PAP3.1729N/B 1”NPT 14 17 24 29 PAP3.2023M/B M32 17 20 20 23 PAP3.2023N/B 1”NPT 17 20 20 23 PAP3.2026M/B M32 17 20 23 26 PAP3.2026N/B 1”NPT 17 20 23 26 PAP3.2029M/B M32 17 20 24 29 PAP3.2029N/B 1”NPT 17 20 24 29 PAP3.2323M/B M32 20 23 20 23 PAP3.2323N/B 1”NPT 20 23 20 23 PAP3.2326M/B M32 20 23 23 26 PAP3.2326N/B 1”NPT 20 23 23 26 PAP3.2329M/B M32 20 23 24 29 PAP3.2329N/B 1”NPT 20 23 24 29 PAP4.2335M/B M40 20 23 30 35 PAP4.2335N/B 1 1/4”NPT 20 23 30 35 PAP4.2635M/B M40 23 26 30 35 PAP4.2635N/B 1 1/4”NPT 23 26 30 35 PAP4.2935M/B M40 26 29 30 35 PAP4.2935N/B 1 1/4”NPT 26 29 30 35 PAP4.3241M/B M40 29 32 36 41 PAP4.3241N/B 1 1/4”NPT 29 32 36 41 PAP4.3541M/B M40 32 35,5 36 41 PAP4.3541N/B 1 1/4”NPT 32 35,5 36 41 PAP5.2335M/B M50 20 23 30 35 PAP5.2335N/B 1 1/2”NPT 20 23 30 35 PAP5.2635M/B M50 23 26 30 35 PAP5.2635N/B 1 1/2”NPT 23 26 30 35 PAP5.2935M/B M50 26 29 30 35 PAP5.2935N/B 1 1/2”NPT 26 29 30 35 PAP5.3241M/B M50 29 32 36 41 PAP5.3241N/B 1 1/2”NPT 29 32 36 41 PAP5.3541M/B M50 32 35,5 36 41 PAP5.3541N/B 1 1/2”NPT 32 35,5 36 41 PAP6.3547M/B M63 32 35,5 42 47 PAP6.3547N/B 2”NPT 32 35,5 42 47 PAP6.3947M/B M63 36 39 42 47 PAP6.3947N/B 2”NPT 36 39 42 47 PAP6.4250M/B M63 39 42 46 50 PAP6.4250N/B 2”NPT 39 42 46 50 PAP6.4255M/B M63 39 42 50 55 PAP6.4255N/B 2”NPT 39 42 50 55 PAP6.4755M/B M63 44 47 50 55 PAP6.4755N/B 2”NPT 44 47 50 55 PAP7.4759M/B M75 44 47 55 59 PAP7.4759N/B 2 1/2”NPT 44 47 55 59 www.ysebaert.be ● info@ysebaert.be ● T +32(0)3 328 06 60 ● F +32(0)3 328 06 80 171 8 Cable glands and accessories 1 Glands 5 Ex barrier metal - double compression: PAP/B Product Code Thread Cable diameter A Min Max B Min Max 59 PAP7.5259M/B M75 50 52 55 PAP7.5259N/B 2 1/2”NPT 50 52 55 59 PAP8.5770M/B M85 52 57 65 70 PAP8.5770N/B 3”NPT 52 57 65 70 PAP8.6170M/B M85 57 61 65 70 PAP8.6170N/B 3”NPT 57 61 65 70 PAP8A.6578M/B M85 61 65 70 78 PAP8A.6578N/B 3”NPT 61 65 70 78 PAP8A.6878M/B M85 65 68 70 78 PAP8A.6878N/B 3”NPT 65 68 70 78 PAP10.7385M/B M110 68 73 78 85 PAP10.7385N/B 4”NPT 68 73 78 85 PAP10.7892M/B M110 74 78 85 92 PAP10.7892N/B 4”NPT 74 78 85 92 Dimensional sketches PAP3-10 PAP1R-2R 172 Product code Dimensions D F G H PAP1R0713M/B 17 62 27 31 PAP1R0713N/B 17 62 27 31 PAP1R0718M/B 17 62 27 31 PAP1R0718N/B 17 62 27 31 PAP1R0913M/B 17 62 27 31 PAP1R0913N/B 17 62 27 31 PAP1R0918M/B 17 62 27 31 PAP1R0918N/B 17 62 27 31 PAP1R1213M/B 17 62 27 31 PAP1R1213N/B 17 62 27 31 PAP1R1218M/B 17 62 27 31 PAP1R1218N/B 17 62 27 31 PAP2R1219M/B 17 62 32 37 PAP2R1219N/B 17 62 32 37 PAP2R1223M/B 17 62 32 37 PAP2R1223N/B 17 62 32 37 PAP2R1419M/B 17 62 32 37 PAP2R1419N/B 17 62 32 37 PAP2R1423M/B 17 62 32 37 PAP2R1423N/B 17 62 32 37 PAP2R1719M/B 17 62 32 37 PAP2R1719N/B 17 62 32 37 PAP2R1723M/B 17 62 32 37 PAP2R1723N/B 17 62 32 37 PAP3.1723M/B 21 88 43 46 PAP3.1723N/B 21 88 43 46 PAP3.1726M/B 21 88 43 46 PAP3.1726N/B 21 88 43 46 PAP3.1729M/B 21 88 43 46 PAP3.1729N/B 21 88 43 46 PAP3.2023M/B 21 88 43 46 PAP3.2023N/B 21 88 43 46 PAP3.2026M/B 21 88 43 46 PAP3.2026N/B 21 88 43 46 PAP3.2029M/B 21 88 43 46 For certificates, spare parts, light intensity diagrams, etc., please consult our website: www.ysebaert.be 8 Cable glands and accessories 1 Glands 5 Ex barrier metal - double compression: PAP/B Product code Dimensions D F G H PAP3.2029N/B 21 88 43 46 PAP3.2323M/B 21 88 43 46 PAP3.2323N/B 21 88 43 46 PAP3.2326M/B 21 88 43 46 PAP3.2326N/B 21 88 43 46 PAP3.2329M/B 21 88 43 46 PAP3.2329N/B 21 88 43 46 PAP4.2335M/B 21 88 59 63 PAP4.2335N/B 21 88 59 63 PAP4.2635M/B 21 88 59 63 PAP4.2635N/B 21 88 59 63 PAP4.2935M/B 21 88 59 63 PAP4.2935N/B 21 88 59 63 PAP4.3241M/B 21 88 59 63 PAP4.3241N/B 21 88 59 63 PAP4.3541M/B 21 88 59 63 PAP4.3541N/B 21 88 59 63 PAP5.2335M/B 21 88 59 63 PAP5.2335N/B 21 88 59 63 PAP5.2635M/B 21 88 59 63 PAP5.2635N/B 21 88 59 63 PAP5.2935M/B 21 88 59 63 PAP5.2935N/B 21 88 59 63 PAP5.3241M/B 21 88 59 63 PAP5.3241N/B 21 88 59 63 PAP5.3541M/B 21 88 59 63 PAP5.3541N/B 21 88 59 63 PAP6.3547M/B 23 92 68 74 PAP6.3547N/B 23 92 68 74 PAP6.3947M/B 23 92 68 74 PAP6.3947N/B 23 92 68 74 PAP6.4250M/B 23 92 68 74 PAP6.4250N/B 23 92 68 74 PAP6.4255M/B 23 92 68 74 PAP6.4255N/B 23 92 68 74 PAP6.4755M/B 23 92 68 74 PAP6.4755N/B 23 92 68 74 PAP7.4759M/B 26 92 82 88 PAP7.4759N/B 26 92 82 88 PAP7.5259M/B 26 92 82 88 PAP7.5259N/B 26 92 82 88 PAP8.5770M/B 26 115 100 118 PAP8.5770N/B 26 115 100 118 PAP8.6170M/B 26 115 100 118 PAP8.6170N/B 26 115 100 118 PAP8A.6578M/B 26 115 100 118 PAP8A.6578N/B 26 115 100 118 PAP8A.6878M/B 26 115 100 118 PAP8A.6878N/B 26 115 100 118 PAP10.7385M/B 28 117 128 PAP10.7385N/B 28 117 128 PAP10.7892M/B 28 117 128 PAP10.7892N/B 28 117 128 Compound Code Description PAP-COMPOUND-1 kit 100g, consisting of: bottle A, bottle B, gloves, syringe, stirring rod, mixing jar PAP-COMPOUND-3 kit 300g, consisting of: bottle A, bottle B, gloves, 3 syringes, 3 stirring rods, 3 mixing jars www.ysebaert.be ● info@ysebaert.be ● T +32(0)3 328 06 60 ● F +32(0)3 328 06 80 173 8 Cable glands and accessories 1 Glands 6 Ex barrier metal - double compression for lead cable: PPAP/B Our barrier glands are composed identically to the classic PPAP-glands. However an extra metal ring is added in the body which will be filled with a II 2 G Exd IIC / Exe II II 2 D ExtD A21 IP66 compound. Whether you should use a barrier gland or not can be deducted from the flowchart below. Suited for armoured cables with lead sheaths. Sealing on inner and outer sheath of the cable. Compression of the cable’s armouring. With lead plate for earthing continuousity. Mechanical protection IP66 in all positions. Zone 1 Zone 2 Zone 21 Zone 22 INERIS03ATEX0028 Specifications Material cable gland Protection Seal Thread Ambiant temperature brass OT 58 IP66 neoprene NPT in accordance with ANSI B2.1 Metric - pitch 1,5 -20°C - +80°C On request • • • • • copper-free aluminium (type ../A) stainless steel 316 (type ../S6) stainless steel 304 (type ../S4) nickel-plated brass (type ../N) ambiant temperature -40°C Ordering data Product code 174 Thread Cable diameter A Min Max B Min Max 13 PPAP1R0713M/B M20 4 7 9 PPAP1R0713N/B 1/2”NPT 4 7 9 13 PPAP1R0718M/B M20 4 7 13 18 PPAP1R0718N/B 1/2”NPT 4 7 13 18 PPAP1R0913M/B M20 7 9,5 9 13 PPAP1R0913N/B 1/2”NPT 7 9,5 9 13 PPAP1R0918M/B M20 7 9,5 13 18 PPAP1R0918N/B 1/2”NPT 7 9,5 13 18 PPAP1R1213M/B M20 9 12 9 13 PPAP1R1213N/B 1/2”NPT 9 12 9 13 PPAP1R1218M/B M20 9 12 13 18 PPAP1R1218N/B 1/2”NPT 9 12 13 18 For certificates, spare parts, light intensity diagrams, etc., please consult our website: www.ysebaert.be 8 Cable glands and accessories 1 Glands 6 Ex barrier metal - double compression for lead cable: PPAP/B Product code Thread Cable diameter A Min Max B Min Max 19 PPAP2R1219M/B M25 9 12 15 PPAP2R1219N/B 3/4”NPT 9 12 15 19 PPAP2R1223M/B M25 9 12 18 23 PPAP2R1223N/B 3/4”NPT 9 12 18 23 PPAP2R1419M/B M25 12 14,5 15 19 PPAP2R1419N/B 3/4”NPT 12 14,5 15 19 PPAP2R1423M/B M25 12 14,5 18 23 PPAP2R1423N/B 3/4”NPT 12 14,5 18 23 PPAP2R1719M/B M25 14 17 15 19 PPAP2R1719N/B 3/4”NPT 14 17 15 19 PPAP2R1723M/B M25 14 17 18 23 PPAP2R1723N/B 3/4”NPT 14 17 18 23 PPAP3.1723M/B M32 14 17 20 23 PPAP3.1723N/B 1”NPT 14 17 20 23 PPAP3.1726M/B M32 14 17 23 26 PPAP3.1726N/B 1”NPT 14 17 23 26 PPAP3.1729M/B M32 14 17 24 29 PPAP3.1729N/B 1”NPT 14 17 24 29 PPAP3.2023M/B M32 17 20 20 23 PPAP3.2023N/B 1”NPT 17 20 20 23 PPAP3.2026M/B M32 17 20 23 26 PPAP3.2026N/B 1”NPT 17 20 23 26 PPAP3.2029M/B M32 17 20 24 29 PPAP3.2029N/B 1”NPT 17 20 24 29 PPAP3.2323M/B M32 20 23 20 23 PPAP3.2323N/B 1”NPT 20 23 20 23 PPAP3.2326M/B M32 20 23 23 26 PPAP3.2326N/B 1”NPT 20 23 23 26 PPAP3.2329M/B M32 20 23 24 29 PPAP3.2329N/B 1”NPT 20 23 24 29 PPAP4.2335M/B M40 20 23 30 35 PPAP4.2335N/B 1 1/4”NPT 20 23 30 35 PPAP4.2635M/B M40 23 26 30 35 PPAP4.2635N/B 1 1/4”NPT 23 26 30 35 PPAP4.2935M/B M40 26 29 30 35 PPAP4.2935N/B 1 1/4”NPT 26 29 30 35 PPAP4.3241M/B M40 29 32 36 41 PPAP4.3241N/B 1 1/4”NPT 29 32 36 41 PPAP4.3541M/B M40 32 35,5 36 41 PPAP4.3541N/B 1 1/4”NPT 32 35,5 36 41 PPAP5.2335M/B M50 20 23 30 35 PPAP5.2335N/B 1 1/2”NPT 20 23 30 35 PPAP5.2635M/B M50 23 26 30 35 PPAP5.2635N/B 1 1/2”NPT 23 26 30 35 PPAP5.2935M/B M50 26 29 30 35 PPAP5.2935N/B 1 1/2”NPT 26 29 30 35 PPAP5.3241M/B M50 29 32 36 41 PPAP5.3241N/B 1 1/2”NPT 29 32 36 41 PPAP5.3541M/B M50 32 35,5 36 41 PPAP5.3541N/B 1 1/2”NPT 32 35,5 36 41 PPAP6.3547M/B M63 32 35,5 42 47 PPAP6.3547N/B 2”NPT 32 35,5 42 47 PPAP6.3947M/B M63 36 39 42 47 PPAP6.3947N/B 2”NPT 36 39 42 47 PPAP6.4250M/B M63 39 42 46 50 PPAP6.4250N/B 2”NPT 39 42 46 50 PPAP6.4255M/B M63 39 42 50 55 PPAP6.4255N/B 2”NPT 39 42 50 55 PPAP6.4755M/B M63 44 47 50 55 PPAP6.4755N/B 2”NPT 44 47 50 55 PPAP7.4759M/B M75 44 47 55 59 PPAP7.4759N/B 2 1/2”NPT 44 47 55 59 www.ysebaert.be ● info@ysebaert.be ● T +32(0)3 328 06 60 ● F +32(0)3 328 06 80 175 8 Cable glands and accessories 1 Glands 6 Ex barrier metal - double compression for lead cable: PPAP/B Product code Thread Cable diameter A Min Max B Min Max 59 PPAP7.5259M/B M75 50 52 55 PPAP7.5259N/B 2 1/2”NPT 50 52 55 59 PPAP8.5770M/B M85 52 57 65 70 PPAP8.5770N/B 3”NPT 52 57 65 70 PPAP8.6170M/B M85 57 61 65 70 PPAP8.6170N/B 3”NPT 57 61 65 70 PPAP8A.6578M/B M85 61 65 70 78 PPAP8A.6578N/B 3”NPT 61 65 70 78 PPAP8A.6878M/B M85 65 68 70 78 PPAP8A.6878N/B 3”NPT 65 68 70 78 PPAP10.7385M/B M110 68 73 78 85 PPAP10.7385N/B 4”NPT 68 73 78 85 PPAP10.7892M/B M110 74 78 85 92 PPAP10.7892N/B 4”NPT 74 78 85 92 Dimensional sketches PPAP3-10 PPAP1R-2R 176 Product code Dimensions D F G H PPAP1R0713M/B 17 62 27 31 PPAP1R0713N/B 17 62 27 31 PPAP1R0718M/B 17 62 27 31 PPAP1R0718N/B 17 62 27 31 PPAP1R0913M/B 17 62 27 31 PPAP1R0913N/B 17 62 27 31 PPAP1R0918M/B 17 62 27 31 PPAP1R0918N/B 17 62 27 31 PPAP1R1213M/B 17 62 27 31 PPAP1R1213N/B 17 62 27 31 PPAP1R1218M/B 17 62 27 31 PPAP1R1218N/B 17 62 27 31 PPAP2R1219M/B 17 62 32 37 PPAP2R1219N/B 17 62 32 37 PPAP2R1223M/B 17 62 32 37 PPAP2R1223N/B 17 62 32 37 PPAP2R1419M/B 17 62 32 37 PPAP2R1419N/B 17 62 32 37 PPAP2R1423M/B 17 62 32 37 PPAP2R1423N/B 17 62 32 37 PPAP2R1719M/B 17 62 32 37 PPAP2R1719N/B 17 62 32 37 PPAP2R1723M/B 17 62 32 37 PPAP2R1723N/B 17 62 32 37 PPAP3.1723M/B 21 88 43 46 PPAP3.1723N/B 21 88 43 46 PPAP3.1726M/B 21 88 43 46 PPAP3.1726N/B 21 88 43 46 PPAP3.1729M/B 21 88 43 46 PPAP3.1729N/B 21 88 43 46 PPAP3.2023M/B 21 88 43 46 PPAP3.2023N/B 21 88 43 46 PPAP3.2026M/B 21 88 43 46 PPAP3.2026N/B 21 88 43 46 PPAP3.2029M/B 21 88 43 46 For certificates, spare parts, light intensity diagrams, etc., please consult our website: www.ysebaert.be 8 Cable glands and accessories 1 Glands 6 Ex barrier metal - double compression for lead cable: PPAP/B Product code Dimensions D F G H PPAP3.2029N/B 21 88 43 46 PPAP3.2323M/B 21 88 43 46 PPAP3.2323N/B 21 88 43 46 PPAP3.2326M/B 21 88 43 46 PPAP3.2326N/B 21 88 43 46 PPAP3.2329M/B 21 88 43 46 PPAP3.2329N/B 21 88 43 46 PPAP4.2335M/B 21 88 59 63 PPAP4.2335N/B 21 88 59 63 PPAP4.2635M/B 21 88 59 63 PPAP4.2635N/B 21 88 59 63 PPAP4.2935M/B 21 88 59 63 PPAP4.2935N/B 21 88 59 63 PPAP4.3241M/B 21 88 59 63 PPAP4.3241N/B 21 88 59 63 PPAP4.3541M/B 21 88 59 63 PPAP4.3541N/B 21 88 59 63 PPAP5.2335M/B 21 88 59 63 PPAP5.2335N/B 21 88 59 63 PPAP5.2635M/B 21 88 59 63 PPAP5.2635N/B 21 88 59 63 PPAP5.2935M/B 21 88 59 63 PPAP5.2935N/B 21 88 59 63 PPAP5.3241M/B 21 88 59 63 PPAP5.3241N/B 21 88 59 63 PPAP5.3541M/B 21 88 59 63 PPAP5.3541N/B 21 88 59 63 PPAP6.3547M/B 23 92 68 74 PPAP6.3547N/B 23 92 68 74 PPAP6.3947M/B 23 92 68 74 PPAP6.3947N/B 23 92 68 74 PPAP6.4250M/B 23 92 68 74 PPAP6.4250N/B 23 92 68 74 PPAP6.4255M/B 23 92 68 74 PPAP6.4255N/B 23 92 68 74 PPAP6.4755M/B 23 92 68 74 PPAP6.4755N/B 23 92 68 74 PPAP7.4759M/B 26 92 82 88 PPAP7.4759N/B 26 92 82 88 PPAP7.5259M/B 26 92 82 88 PPAP7.5259N/B 26 92 82 88 PPAP8.5770M/B 26 115 100 118 PPAP8.5770N/B 26 115 100 118 PPAP8.6170M/B 26 115 100 118 PPAP8.6170N/B 26 115 100 118 PPAP8A.6578M/B 26 115 100 118 PPAP8A.6578N/B 26 115 100 118 PPAP8A.6878M/B 26 115 100 118 PPAP8A.6878N/B 26 115 100 118 PPAP10.7385M/B 28 117 128 PPAP10.7385N/B 28 117 128 PPAP10.7892M/B 28 117 128 PPAP10.7892N/B 28 117 128 Compound Code Description PAP-COMPOUND-1 kit 100g, consisting of: bottle A, bottle B, gloves, syringe, stirring rod, mixing jar PAP-COMPOUND-3 kit 300g, consisting of: bottle A, bottle B, gloves, 3 syringes, 3 stirring rods, 3 mixing jars www.ysebaert.be ● info@ysebaert.be ● T +32(0)3 328 06 60 ● F +32(0)3 328 06 80 177 8 Cable glands and accessories 1 Glands 7 Exe-plastic / metric thread Suited for armoured and non-armoured cables. Sealing on outer sheath of the cable. Maximum strain relief because of a patented lamella system. Irreversible threads prevent stripping under high torque and protect against vibration. Zone 1 Specifications Zone 2 Protection Material cable gland Material closure Material O-ring Ambiant temperature IP68 - 5 bar (30 min) polyamide (self-extinguishing) EPDM EPDM -40°C - +75°C II 2 G Exe II II 2 D Ex tD A21 Zone 21 Zone 22 PTB05ATEX1068X On request • PG or NPT thread Ordering data 178 Product code Thread Cable diameter Min Max GPEM1 M16 x 1.5 4 9 GPEM2 M20 x 1.5 6 13 GPEM3 M25 x 1.5 7 17 GPEM4 M32 x 1.5 13 21 GPEM5 M40 x 1.5 17 28 GPEM6 M50 x 1.5 23 35 GPEM7 M63 x 1.5 31 48 GPIM1 M16 x 1.5 4 9 GPIM2 M20 x 1.5 6 13 GPIM3 M25 x 1.5 7 17 GPIM4 M32 x 1.5 13 21 GPIM5 M40 x 1.5 17 28 GPIM6 M50 x 1.5 23 35 GPIM7 M63 x 1.5 31 48 For certificates, spare parts, light intensity diagrams, etc., please consult our website: www.ysebaert.be 8 Cable glands and accessories 1 Glands 7 Exe-plastic / metric thread Dimensional sketches Product code Dimensions A B SW GPEM1 31 - 37 9 20 GPEM2 36 - 45 10 24 GPEM3 38 - 47 10 29 GPEM4 42 - 51 12 36 GPEM5 52 - 65 12 46 GPEM6 59 - 72 14 55 GPEM7 64 - 78 15 68 GPIM1 31 - 37 9 20 GPIM2 36 - 45 10 24 GPIM3 38 - 47 10 29 GPIM4 42 - 51 12 36 GPIM5 52 - 65 12 46 GPIM6 59 - 72 14 55 GPIM7 64 - 78 15 68 Accessories Code Description BS8 Plug for cable 8mm MFV12 Plug for cable 12mm MFV17 Plug for cable 17mm MFV21 Plug for cable 21mm www.ysebaert.be ● info@ysebaert.be ● T +32(0)3 328 06 60 ● F +32(0)3 328 06 80 179 8 Cable glands and accessories 2 Plugs 1 Exd brass Plugs are used to safely seal unused openings in enclosures and apparatuses.There are two types:- R18; the plug is screwed in on the outside and fastened with a hexagonal spanner on the inside (on request). RX18; the plug is screwed in and fastened with a hexagonal spanner on the outside (standard model). II 2 GD Exd II C Zone 1 Zone 2 Zone 21 Zone 22 SIRA00ATEX1073U Specifications Marking Material Thread Protection Ambiant temperature All plugs are marked with a certificate number and size. brass - NPT in accordance with ANSI B2.1 - Metric IP65 -190°C - +400°C On request • • • • • aluminium stainless steel nickel-plated brass steel thread: PG, BSP (conical & parallel), ET (electrical thread) Ordering data 180 Code Thread PBDM1X M16x1,5 PBDM2X M20x1,5 PBDM3X M25x1,5 PBDM4X M32x1,5 PBDM5X M40x1,5 PBDM6X M50x1,5 PBDM7X M63x1,5 PBDM8X M75x1,5 PBDN0X 1/4” NPT PBDN1X 1/2” NPT PBDN2X 3/4” NPT PBDN3X 1” NPT PBDN4X 1 1/4” NPT PBDN5X 1 1/2” NPT PBDN6X 2” NPT PBDN7X 2 1/2” NPT PBDN8X 3” NPT PBDN9X 3 1/2” NPT PBDN10X 4” NPT For certificates, spare parts, light intensity diagrams, etc., please consult our website: www.ysebaert.be 8 Cable glands and accessories 2 Plugs 2 Exe brass Plugs are used to safely seal unused openings in enclosures and apparatuses. The plug is screwed in and fastened with a hexagonal Allen key on the outside. Specifications Marking All plugs are marked with a certificate number and size. brass - NPT in accordance with ANSI B2.1 - metric IP68 -50°C - +120°C Material Thread Protection Ambiant temperature II 2 GD Exe II Zone 1 Zone 2 Zone 21 Zone 22 SIRA00ATEX1073U On request • • • • • aluminium stainless steel nickel-plated brass steel thread: PG, BSP (conical & parallel), ET (electrical thread) Ordering data Code Thread PBEM1 M16x1.5 PBEM2 M20x1.5 PBEM3 M25x1.5 PBEM4 M32x1.5 PBEM5 M40x1.5 PBEM6 M50x1.5 PBEM7 M63x1.5 PBEM8 M75x1.5 PBEN0 1/4” NPT PBEN1 1/2” NPT PBEN2 3/4” NPT PBEN3 1” NPT PBEN4 1 1/4” NPT PBEN5 1 1/2” NPT PBEN6 2” NPT PBEN7 2 1/2” NPT PBEN8 3” NPT PBEN9 3 1/2” NPT PBEN10 4” NPT Dimensional sketches www.ysebaert.be ● info@ysebaert.be ● T +32(0)3 328 06 60 ● F +32(0)3 328 06 80 181 8 Cable glands and accessories 2 Plugs 3 Exe plastic Plugs are used to safely seal unused openings in enclosures and apparatuses. The plug is screwed in and fastened with a spanner on the outside. II 2 G Exe II II 2 D Ex tD A21 Specifications Marking Material Thread Protection Ambiant temperature Zone 1 All plugs are marked with a certificate number and size. nylon Metric IP66 -20°C - +80°C Zone 2 Zone 21 Zone 22 PTB06ATEX1032X On request • PG or NPT thread Ordering data Code Thread PPEM1 M16x1,5 PPEM2 M20x1,5 PPEM3 M25x1,5 PPEM4 M32x1,5 PPEM5 M40x1,5 PPEM6 M50x1,5 PPEM7 M63x1,5 PPEM8 M75x1,5 Dimensional sketches 182 Product code Dimensions A B SW1 SW2 PPEM1 16 9,5 20 10 PPEM2 17,5 11,6 24 10 PPEM3 17 11 29 10 PPEM4 16,5 11 36 10 PPEM5 18 10 46 10 PPEM6 21 10 55 10 PPEM7 24 10 68 10 For certificates, spare parts, light intensity diagrams, etc., please consult our website: www.ysebaert.be 8 Cable glands and accessories 3 Reducers and adapters 1 Exd / Exe brass Reducers and adapters are used as a transition piece in case of differing threads in enclosures and glands (or plugs). With reducers the male thread is larger than the female thread. With adapters, however, the male thread is smaller than the female thread and is limited to 1 step (e.g. M20 -> M25). II 2 GD Exde II C Zone 1 Zone 2 Zone 21 Zone 22 SIRA00ATEX1073U Specifications Marking Material Thread Protection Ambiant temperature All reducers and adapters are marked with a certificate number and size. brass - NPT in accordance with ANSI B2.1 - Metric - PG IP65 -50°C - +120°C On request • • • • • aluminium stainless steel nickel-plated brass steel thread: BSP (conical & parallel), ET (electrical thread) Ordering data male thread metric - female thread metric = reductie = adapter Male M16 M20 M16 ABDM1M1 RBDM2M1 RBDM3M1 RBDM4M1 RBDM5M1 RBDM6M1 RBDM7M1 RBDM8M1 M20 ABDM1M2 ABDM2M2 RBDM3M2 RBDM4M2 RBDM5M2 RBDM6M2 RBDM7M2 RBDM8M2 ABDM2M3 ABDM3M3 RBDM4M3 RBDM5M3 RBDM6M3 RBDM7M3 RBDM8M3 ABDM3M4 ABDM4M4 RBDM5M4 RBDM6M4 RBDM7M4 RBDM8M4 ABDM4M5 ABDM5M5 RBDM6M5 RBDM7M5 RBDM8M5 ABDM6M6 RBDM7M6 RBDM8M6 ABDM6M7 ABDM7M7 RBDM8M7 ABDM7M8 ABDM8M8 M63 M75 Female M25 M32 M25 M40 M32 M50 M40 ABDM5M6 M63 M50 M75 M63 M75 male thread metric - female thread NPT = reductie = adapter Female Male 1/2”NPT 3/4”NPT 1”NPT 1 1/4” NPT 1 1/2” NPT 2” NPT 2 1/2” NPT M16 ABDM1N1 M20 M25 M32 M40 M50 ABDM2N1 RBDM3N1 RBDM4N1 RBDM5N1 RBDM6N1 RBDM7N1 RBDM8N1 ABDM2N2 ABDM3N2 RBDM4N2 RBDM5N2 RBDM6N2 RBDM7N2 RBDM8N2 ABDM3N3 ABDM4N3 RBDM5N3 RBDM6N3 RBDM7N3 RBDM8N3 ABDM4N4 ABDM5N4 RBDM6N4 RBDM7N4 RBDM8N4 ABDM5N5 ABDM6N5 RBDM7N5 RBDM8N5 ABDM7N6 RBDM8N6 ABDM7N7 ABDM8N7 ABDM6N6 3” NPT ABDM8N8 3 1/2” NPT 4” NPT www.ysebaert.be ● info@ysebaert.be ● T +32(0)3 328 06 60 ● F +32(0)3 328 06 80 183 8 Cable glands and accessories 3 Reducers and adapters 1 Exd / Exe brass male thread PG - female thread metric = reductie = adapter Male PG7 PG9 PG11 PG13,5 PG16 PG21 PG29 PG36 PG42 PG48 ABDP0M1 ABDP1M1 ABDP2M1 RBDP3M1 RBDP4M1 RBDP5M1 RBDP6M1 RBDP7M1 RBDP8M1 RBDP9M1 ABDP3M2 ABDP4M2 RBDP5M2 RBDP6M2 RBDP7M2 RBDP8M2 RBDP9M2 ABDP3M3 ABDP4M3 ABDP5M3 RBDP6M3 RBDP7M3 RBDP8M3 RBDP9M3 ABDP5M4 RBDP6M4 RBDP7M4 RBDP8M4 RBDP9M4 ABDP6M5 RBDP7M5 RBDP8M5 RBDP9M5 M50 RBDP7M6 ABDP8M6 RBDP9M6 M63 ABDP7M7 ABDP8M7 ABDP9M7 Female M16 M20 ABDP2M2 M25 M32 M40 M75 ABDP9M8 male thread PG - female thread NPT = reductie = adapter Female Male 1/2”NPT PG7 PG9 PG11 PG13,5 PG16 PG21 PG29 PG36 PG42 PG48 ABDP0N1 ABDP1N1 ABDP2N1 ABDP3N1 ABDP4N1 RBDP5N1 RBDP6N1 RBDP7N1 RBDP8N1 RBDP9N1 ABDP3N2 ABDP4N2 3/4”NPT 1”NPT ABDP5N2 RBDP6N2 RBDP7N2 RBDP8N2 RBDP9N2 ABDP5N3 RBDP6N3 RBDP7N3 RBDP8N3 RBDP9N3 ABDP6N4 RBDP7N4 RBDP8N4 RBDP9N4 ABDP7N5 ABDP8N5 RBDP9N5 1 1/4” NPT 1 1/2” NPT 2” NPT ABDP8N6 2 1/2” NPT ABDP9N6 ABDP9N7 3” NPT 3 1/2” NPT 4” NPT male thread NPT - female thread metric = reductie = adapter Male 1/2”NPT 3/4”NPT 1”NPT 1 1/4” NPT 1 1/2” NPT 2” NPT 2 1/2” NPT 3” NPT 3 1/2” NPT 4” NPT M16 RBDN1M1 RBDN2M1 RBDN3M1 RBDN4M1 RBDN5M1 RBDN6M1 RBDN7M1 RBDN8M1 RBDN9M1 RBDN10M1 M20 ABDN1M2 RBDN2M2 RBDN3M2 RBDN4M2 RBDN5M2 RBDN6M2 RBDN7M2 RBDN8M2 RBDN9M2 RBDN10M2 M25 ABDN1M3 ABDN2M3 RBDN3M3 RBDN4M3 RBDN5M3 RBDN6M3 RBDN7M3 RBDN8M3 RBDN9M3 RBDN10M3 ABDN2M4 ABDN3M4 RBDN4M4 RBDN5M4 RBDN6M4 RBDN7M4 RBDN8M4 RBDN9M4 RBDN10M4 ABDN4M5 RBDN5M5 RBDN6M5 RBDN7M5 RBDN8M5 RBDN9M5 RBDN10M5 ABDN4M6 ABDN5M6 RBDN6M6 RBDN7M6 RBDN8M6 RBDN9M6 RBDN10M6 ABDN5M7 ABDN6M7 RBDN7M7 RBDN8M7 RBDN9M7 RBDN10M7 ABDN6M7 ABDN7M7 RBDN8M8 RBDN9M8 RBDN10M8 Female M32 M40 ABDN3M5 M50 M63 M75 male thread NPT - female thread NPT = reductie = adapter Male 1/2”NPT 3/4”NPT 1”NPT 1 1/4” NPT 1 1/2” NPT 2” NPT 2 1/2” NPT 3” NPT 3 1/2” NPT 4” NPT 1/2”NPT ABDN1N1 RBDN2N1 RBDN3N1 RBDN4N1 RBDN5N1 RBDN6N1 RBDN7N1 RBDN8N1 RBDN9N1 RBDN10N1 3/4”NPT ABDN1N2 ABDN2N2 RBDN3N2 RBDN4N2 RBDN5N2 RBDN6N2 RBDN7N2 RBDN8N2 RBDN9N2 RBDN10N2 ABDN3N3 RBDN4N3 RBDN5N3 RBDN6N3 RBDN7N3 RBDN8N3 RBDN9N3 RBDN10N3 ABDN3N4 ABDN4N4 RBDN5N4 RBDN6N4 RBDN7N4 RBDN8N4 RBDN9N4 RBDN10N4 ABDN5N5 RBDN6N5 RBDN7N5 RBDN8N5 RBDN9N5 RBDN10N5 ABDN5N6 ABDN6N6 RBDN7N6 RBDN8N6 RBDN9N6 RBDN10N6 ABDN7N7 RBDN8N7 RBDN9N7 RBDN10N7 ABDN7N8 ABDN8N8 RBDN9N8 RBDN10N8 ABDN9N9 RBDN10N9 Female 1”NPT 1 1/4” NPT 1 1/2” NPT 2” NPT 2 1/2” NPT 3” NPT 3 1/2” NPT 4” NPT 184 ABDN2N3 ABDN4N5 ABDN6N7 ABDN9N10 ABDN10N10 For certificates, spare parts, light intensity diagrams, etc., please consult our website: www.ysebaert.be 8 Cable glands and accessories 3 Reducers and adapters 2 Exe plastic Reducers and adapters are used as a transition piece in case of differing threads in enclosures and glands (or plugs). With reducers the male thread is larger than the female thread. With adapters, however, the male thread is smaller than the female thread and is limited to 1 step (e.g. M20 -> M25). Zone 1 Specifications Zone 2 Marking Material Thread Protection Ambiant temperature All reducers and adapters are marked with a certificate number and size. nylon (polyamide) - NPT in accordance with ANSI B2.1 - Metric - PG IP66 -20°C - +60°C II 2 G Exe II II 2 D Ex tD A21 Zone 21 Zone 22 SIRA00ATEX1073U PTB04ATEX1040X On request • • • • • • brass aluminium stainless steel nickel-plated brass steel thread: BSP (conical & parallel), ET (electrical thread) Ordering data male thread metric - female thread metric = reductie = adapter Male M16 M20 M25 M32 M40 M50 M63 M75 M16 APEM1M1 RPEM2M1 RPEM3M1 RPEM4M1 RPEM5M1 RPEM6M1 RPEM7M1 RPEM8M1 M20 APEM1M2 APEM2M2 RPEM3M2 RPEM4M2 RPEM5M2 RPEM6M2 RPEM7M2 RPEM8M2 APEM2M3 APEM3M3 RPEM4M3 RPEM5M3 RPEM6M3 RPEM7M3 RPEM8M3 APEM3M4 APEM4M4 RPEM5M4 RPEM6M4 RPEM7M4 RPEM8M4 APEM5M5 RPEM6M5 RPEM7M5 RPEM8M5 APEM5M6 APEM6M6 RPEM7M6 RPEM8M6 APEM7M7 RPEM8M7 APEM7M8 APEM8M8 Female M25 M32 M40 APEM4M5 M50 M63 APEM6M7 M75 male thread metric - female thread NPT = reductie = adapter Female Male 1/2”NPT 3/4”NPT 1”NPT 1 1/4” NPT 1 1/2” NPT 2” NPT 2 1/2” NPT M16 M20 M25 M32 M40 M50 M63 M75 APEM1N1 APEM2N1 RPEM3N1 RPEM4N1 RPEM5N1 RPEM6N1 RPEM7N1 RPEM8N1 APEM2N2 APEM3N2 RPEM4N2 RPEM5N2 RPEM6N2 RPEM7N2 RPEM8N2 APEM3N3 APEM4N3 RPEM5N3 RPEM6N3 RPEM7N3 RPEM8N3 APEM4N4 APEM5N4 RPEM6N4 RPEM7N4 RPEM8N4 APEM6N5 RPEM7N5 RPEM8N5 APEM6N6 APEM7N6 RPEM8N6 APEM5N5 APEM7N7 3” NPT APEM8N7 APEM8N8 3 1/2” NPT 4” NPT www.ysebaert.be ● info@ysebaert.be ● T +32(0)3 328 06 60 ● F +32(0)3 328 06 80 185 8 Cable glands and accessories 3 Reducers and adapters 2 Exe plastic male thread PG - female thread metric = reductie = adapter Male PG7 PG9 PG11 PG13,5 PG16 PG21 PG29 PG36 PG42 PG48 APEP0M1 APEP1M1 APEP2M1 RPEP3M1 RPEP4M1 RPEP5M1 RPEP6M1 RPEP7M1 RPEP8M1 RPEP9M1 APEP3M2 APEP4M2 RPEP5M2 RPEP6M2 RPEP7M2 RPEP8M2 RPEP9M2 APEP3M3 APEP4M3 APEP5M3 RPEP6M3 RPEP7M3 RPEP8M3 RPEP9M3 APEP5M4 RPEP6M4 RPEP7M4 RPEP8M4 RPEP9M4 APEP6M5 RPEP7M5 RPEP8M5 RPEP9M5 M50 RPEP7M6 APEP8M6 RPEP9M6 M63 APEP7M7 APEP8M7 APEP9M7 Female M16 M20 APEP2M2 M25 M32 M40 M75 APEP9M8 male thread PG - female thread NPT = reductie = adapter Female Male 1/2”NPT PG7 PG9 PG11 PG13,5 PG16 PG21 PG29 PG36 PG42 PG48 APEP0N1 APEP1N1 APEP2N1 APEP3N1 APEP4N1 RPEP5N1 RPEP6N1 RPEP7N1 RPEP8N1 RPEP9N1 APEP3N2 APEP4N2 3/4”NPT 1”NPT APEP5N2 RPEP6N2 RPEP7N2 RPEP8N2 RPEP9N2 APEP5N3 RPEP6N3 RPEP7N3 RPEP8N3 RPEP9N3 APEP6N4 RPEP7N4 RPEP8N4 RPEP9N4 APEP7N5 APEP8N5 RPEP9N5 APEP8N6 APEP9N6 1 1/4” NPT 1 1/2” NPT 2” NPT 2 1/2” NPT APEP9N7 3” NPT 3 1/2” NPT 4” NPT male thread NPT - female thread metric = reductie = adapter Male 1/2”NPT 3/4”NPT 1”NPT 1 1/4” NPT 1 1/2” NPT 2” NPT 2 1/2” NPT 3” NPT 3 1/2” NPT 4” NPT M16 RPEN1M1 RPEN2M1 RPEN3M1 RPEN4M1 RPEN5M1 RPEN6M1 RPEN7M1 RPEN8M1 RPEN9M1 RPEN10M1 M20 APEN1M2 RPEN2M2 RPEN3M2 RPEN4M2 RPEN5M2 RPEN6M2 RPEN7M2 RPEN8M2 RPEN9M2 RPEN10M2 M25 APEN1M3 APEN2M3 RPEN3M3 RPEN4M3 RPEN5M3 RPEN6M3 RPEN7M3 RPEN8M3 RPEN9M3 RPEN10M3 APEN2M4 APEN3M4 RPEN4M4 RPEN5M4 RPEN6M4 RPEN7M4 RPEN8M4 RPEN9M4 RPEN10M4 APEN4M5 RPEN5M5 RPEN6M5 RPEN7M5 RPEN8M5 RPEN9M5 RPEN10M5 APEN4M6 APEN5M6 RPEN6M6 RPEN7M6 RPEN8M6 RPEN9M6 RPEN10M6 APEN6M7 RPEN7M7 RPEN8M7 RPEN9M7 RPEN10M7 APEN6M8 APEN7M8 RPEN8M8 RPEN9M8 RPEN10M8 Female M32 M40 APEN3M5 M50 M63 APEN5M7 M75 male thread NPT - female thread NPT = reductie = adapter Male 1/2”NPT 3/4”NPT 1”NPT 1 1/4” NPT 1 1/2” NPT 2” NPT 2 1/2” NPT 3” NPT 3 1/2” NPT 4” NPT 1/2”NPT APEN1N1 RPEN2N1 RPEN3N1 RPEN4N1 RPEN5N1 RPEN6N1 RPEN7N1 RPEN8N1 RPEN9N1 RPEN10N1 3/4”NPT APEN1N2 APEN2N2 RPEN3N2 RPEN4N2 RPEN5N2 RPEN6N2 RPEN7N2 RPEN8N2 RPEN9N2 RPEN10N2 APEN3N3 RPEN4N3 RPEN5N3 RPEN6N3 RPEN7N3 RPEN8N3 RPEN9N3 RPEN10N3 APEN3N4 APEN4N4 RPEN5N4 RPEN6N4 RPEN7N4 RPEN8N4 RPEN9N4 RPEN10N4 APEN5N5 RPEN6N5 RPEN7N5 RPEN8N5 RPEN9N5 RPEN10N5 APEN5N6 APEN6N6 RPEN7N6 RPEN8N6 RPEN9N6 RPEN10N6 APEN7N7 RPEN8N7 RPEN9N7 RPEN10N7 APEN7N8 APEN8N8 RPEN9N8 RPEN10N8 APEN9N9 RPEN10N9 Female 1”NPT 1 1/4” NPT 1 1/2” NPT 2” NPT 2 1/2” NPT 3” NPT 3 1/2” NPT 4” NPT 186 APEN2N3 APEN4N5 APEN6N7 APEN9N10 APEN10N10 For certificates, spare parts, light intensity diagrams, etc., please consult our website: www.ysebaert.be 8 Cable glands and accessories 4 Accessories 1 Earth tags brass Earth tags provide the possibility of an earthing connection between gland and box, by means of a flexible wire. The standard version is made of brassand, if necessary, can be nickel-plated or stainless steel. Zone 1 Zone 2 Zone 21 Zone 22 Specifications Marking not applicable can be mounted in every zone brass Material On request • • • stainless steel brass nickel plated PG thread Ordering data Code Thread EBNM1 M16 EBNM2 M20 EBNM3 M25 EBNM4 M32 EBNM5 M40 EBNM6 M50 EBNM7 M63 EBNM8 M75 EBNN0 1/4” NPT EBNN1 1/2” NPT EBNN2 3/4” NPT EBNN3 1” NPT EBNN4 1 1/4” NPT EBNN5 1 1/2” NPT EBNN6 2” NPT EBNN7 2 1/2” NPT EBNN8 3” NPT EBNN9 3 1/2” NPT EBNN10 4” NPT www.ysebaert.be ● info@ysebaert.be ● T +32(0)3 328 06 60 ● F +32(0)3 328 06 80 187 8 Cable glands and accessories 4 Accessories 2 Lock nuts The standard version of the hexagonal lock nuts are made of nickel plated brass or plastic. Specifications Marking Zone 1 Zone 2 Zone 21 Zone 22 not applicable can be mounted in every zone On request • NPT or PG thread Ordering data 188 Code Thread Material LPNM1 M16 x 1.5 plastic LPNM2 M20 x 1.5 plastic LPNM3 M25 x 1.5 plastic LPNM4 M32 x 1.5 plastic LPNM5 M40 x 1.5 plastic LPNM6 M50 x 1.5 plastic LPNM7 M63 x 1.5 plastic LNNM1 M16 x 1.5 brass nickel plated LNNM2 M20 x 1.5 brass nickel plated LNNM3 M25 x 1.5 brass nickel plated LNNM4 M32 x 1.5 brass nickel plated LNNM5 M40 x 1.5 brass nickel plated LNNM6 M50 x 1.5 brass nickel plated LNNM7 M63 x 1.5 brass nickel plated LNNM8 M75 x 1.5 brass nickel plated For certificates, spare parts, light intensity diagrams, etc., please consult our website: www.ysebaert.be 8 Cable glands and accessories 4 Accessories 3 Gaskets plastic Gaskets between gland and box increase the watertightness of threaded connections. They are available in various sizes. Specifications Marking Zone 1 Zone 2 Zone 21 Zone 22 not applicable can be mounted in every zone plastic, red fibre Material Ordering data Code Thread WPNM1 M16 WPNM2 M20 WPNM3 M25 WPNM4 M32 WPNM5 M40 WPNM6 M50 WPNM7 M63 WPNM8 M75 WPNN0 1/4” NPT WPNN1 1/2” NPT WPNN2 3/4” NPT WPNN3 1” NPT WPNN4 1 1/4” NPT WPNN5 1 1/2” NPT WPNN6 2” NPT WPNN7 2 1/2” NPT WPNN8 3” NPT WPNN9 3 1/2” NPT WPNN10 4” NPT www.ysebaert.be ● info@ysebaert.be ● T +32(0)3 328 06 60 ● F +32(0)3 328 06 80 189 8 Cable glands and accessories 5 Special passing troughs 1 Drainage valve Drainage valves are used to drain condensation in enclosures. They also serve as ventilation. They are available for EExd and EExe enclosures. Type ECR1 is only approved in housings type EJB and GUB. Specifications Material Thread II 2 GD EExd IIC T6 II 2 G EExe II Zone 1 plastic or stainless steel metric or NPT Zone 2 Zone 21 Zone 22 PTB01ATEX1128X Ordering data 190 Code Classification Material Thread ECR1 EExd IIC T6 stainless steel 3/8” DPEM3 EExe II polyamide M25x1,5 Protection Ambiant temp. IP54 -20°C - +40°C For certificates, spare parts, light intensity diagrams, etc., please consult our website: www.ysebaert.be 8 Cable glands and accessories 5 Special passing troughs 2 Coupling for air/gas In order to feed through air or gas in an explosion-proof EExd enclosure a special coupling must be used, guaranteeing the protection of the EExd enclosure. Specifications Connection Feed-through section Material Thread Allowed media Protection Ambiant temperature II 2 GD EExd IIC Zone 1 Zone 2 2 connections 1/4” BSP(P) max. 3mm² brass or stainless steel M20x1,5 air/gaz IP65 max. +300°C Zone 21 Zone 22 INERIS03ATEX9014U Ordering data Code Thread Material Weight XW8-TL1 M20x1,5 brass 0,200 kg XW8-TL1 INOX M20x1,5 stainless steel 304 0,200 kg www.ysebaert.be ● info@ysebaert.be ● T +32(0)3 328 06 60 ● F +32(0)3 328 06 80 191 9 Miscellaneous 1 Telephones ................................................................................................. 195 1 dST series for zone 1, 2, 21 and 22 ................................................ 195 2 Serie dFT for zone 2 and 22 ........................................................... 196 3 Accessories..................................................................................... 197 2 Earth monitoring system ............................................................................ 198 1 Earth monitoring system ................................................................. 198 www.ysebaert.be ● info@ysebaert.be ● T +32(0)3 328 06 60 ● F +32(0)3 328 06 80 193 9 Miscellaneous 1 Telephones 1 dST series for zone 1, 2, 21 and 22 Explosionproof telephones may be inevitable in hazardous zones. The dST series offers the ideal solution for use in heavy-duty conditions. The large keys of type dST1 allow operation with gloves. Specifications Housing Protection Terminals Line voltage Line current Ringing voltage Call signal Telephone system Noise suppression Handsfree Gland entry Weight Ambiant temperature glass-fibre reinforced polyester IP66 2,5mm² 24V DC - 66V DC 15mA DC - 100mA DC 24-90V AC (21-54Hz ringing frequency) 30-90V AC (16,6-54Hz ringing frequency) 90 dB(A)/1m 10 different melodies PD - DTMF > 3 dB until 68 dB / 1 m 2 cable glands M20 + 2 plugs M20 5,5 kg -25°C - +40/60°C II 2 G Ex e m [ib] IIC T6/T5 II 2 D Ex tD A21 IP66 T80°C/T100°C Zone 1 Zone 2 Zone 21 Zone 22 On request • • • • extra horn for ringing signal AS1 extra visual-audible sounder for telephone VS1 additional earpiece set EP1 headset kit HS1 Ordering data Code Description Keypad Display dST1 telephone with key pad and display in stainless steel, 21 keys with ABC-letters for name input alphanumeric dST2 emergency telephone (connects directly to main PABX) without key pad and display none none Dimensional sketches www.ysebaert.be ● info@ysebaert.be ● T +32(0)3 328 06 60 ● F +32(0)3 328 06 80 195 9 Miscellaneous 1 Telephones 2 Serie dFT for zone 2 and 22 Explosionproof telephones may be inevitable in hazardous zones. The dFT series offers the ideal solution for use in zone 2 and 22 and in heavy-duty conditions. The large keys allow operation with gloves. Specifications Housing Protection Terminals Line voltage Call signal Telephone system Gland entry Weight Ambiant temperature polycarbonate (yellow, red, gray or black) IP65 2,5mm² 24V DC - 66V DC 95 dB(A)/1m MFV 1 cable gland M20 + 1 plug M20 + 2 plugs M12 2,3 kg -20°C - +55°C II 3 G Ex nA nL IIC T5 II 3 D Ex tD A22 IP65 T80°C Zone 1 Zone 2 Zone 21 Zone 22 Ordering data Code Description Keypad Display dFT3 telephone with key pad and display 21 keys with ABC-letters for name input alphanumeric Dimensional sketches 196 For certificates, spare parts, light intensity diagrams, etc., please consult our website: www.ysebaert.be 9 Miscellaneous 1 Telephones 3 Accessories In combination with the ex-proof telephones, several accessories can be used. Specifications II 2 G Ex mb e [ib] IIC T6 Zone 1 Housing Protection Terminals Call signal Ambiant temperature aluminium IP66 1,5mm² 90dB -20°C - +40°C Zone 2 Zone 21 Zone 22 On request • • additional earpiece set EP1 headset kit HS1 Ordering data Code Description Cable entry Weight Acoustic signalling AS1 extra horn for ringing signal 1 x M20 x 1,5 0,9 kg loudspeaker VS1-R Extra visual-audible 2 x M20 x 1,5 sounder for telephone, red 1,5 kg loudspeaker Visual signalling 2 xenon tubes 1J (230VAC) Dimensional sketches www.ysebaert.be ● info@ysebaert.be ● T +32(0)3 328 06 60 ● F +32(0)3 328 06 80 197 9 Miscellaneous 2 Earth monitoring system 1 Earth monitoring system The monitoring units are widely applicable and very trustworthy: - Specific monitoring systems: detection of resistance or capacity - Safe discharging of sparks with high energy level: inside the enclosures of the monitoring unit. - Permanent electrostatic monitoring of the object. - Intrinsically safe permanent guarding of the earth connection. - Red/green signal lamps for local status indication of the earth connection. - Volt-free contacts for remote control, for instance for turning on a pump. II 1/2 G EExia/d IIC T6 II 2 D IP66 T85°C Zone 1 Zone 2 Zone 21 Zone 22 Specifications Housing Finisching Protection Voltage Volt-free contact Features Gland entry Ambiant temperature cast aluminium Alodine 1200, colour natural or RAL 7032 IP66 230/115VAC ±10% 50/60Hz 0,4W 24VDC ±20% 0,4W 1 change over contact, 1A at 250V AC1 red lamp = no earthing green lamp = proper earthing 4 x M20 x 1,5 -10°C - +40°C On request • Control unit in an industrial housing (IP65, for industrial use, incl. Ex zone 22) Ordering data Code Application Operation S604/EX This is a system with resistance recognition, R <20 ohm. Once the clamp has been for general use (barrels, trucks, attached to the metal object, a low resistance is detected between the two jaws of the 10 kg metal objects,...) clamp. The monitoring unit is activated (green indication lamp on an volt-free contact for remote control). S704/EX for trucks This is a system with capacity recognition and R <20 ohm. First the capacity of the truck is tested. When this is within the prescribed limits, the monitoring unit is activated. 10 kg Since this system cannot be misled, it offers a high degree of security. Dimensional sketches Accessories 198 Weight Code Description CL1 clamp, large format, 260 mm, aluminium CM1 clamp, medium format, 210 mm, stainless steel CS1 clamp, small format, 162 mm, stainless steel CR01/10 cable, 10m, 3x1.5mm² CR1/55 automatic reel, 24m cable, 3x1.5mm², IP55 For certificates, spare parts, light intensity diagrams, etc., please consult our website: www.ysebaert.be