ABQ - IEC Electronics

advertisement
DEFENSE LOGISTICS AGENCY
LAND AND MARITIME
POST OFFICE BOX 3990
COLUMBUS, OH 43218-3990
11 January 2016
Ms. Rachel Garcia
Laboratory Manager
IEC Electronics Analysis and Testing Laboratory
1430 Mission Avenue NE
Albuquerque, NM 87107
Dear Ms. Garcia:
Re: Commercial Laboratory Suitability Name Change, QTSL; FSC 5961/5962; CAGE:
6L8X4, VQC 16-030037, CN: 04250
It has been recognized by DLA Land and Maritime that Dynamic Research Testing Lab
has changed names and will now be IEC Electronics Analysis and Testing Laboratory as of
January 07, 2016. The previous Commercial Laboratory Suitability letter VQC-15-029645 that
was issued to Dynamic Research Testing Lab will be applied to IEC Electronics Analysis and
Testing Laboratory based on the results of the DLA Land and Maritime audit conducted 9-10
June 2015, IEC Electronics Analysis and Testing Laboratory is considered suitably equipped to
perform the QTSL and MIL-STD-750 tests listed in the enclosure. This testing shall be
performed on devices in accordance with the requirements of DLA Land and Maritime’s QTSL
program effective immediately.
Your laboratory is to maintain a record for all microcircuit testing and submit a summary
annually to DLA Land and Maritime-VQ which will include the following as a minimum:
a.
b.
c.
d.
e.
f.
g.
h.
i.
j.
Part number, SMD, or MIL-STD identification
Date code
Quantity tested
Number of devices pass/fail
Manufacturer
Manufacturer’s lot number
Test method(s)/condition(s)
Date test completed
Qualification test report number as applicable
Self audit reports with deficiencies and corrective actions
The standard retention reporting period is from 1 May through 30 April. Your present
reporting period is from 1 May 2015 through 30 April 2016 and due by 01 June 2016.
Test labs shall notify the qualifying activity immediately after learning of a potential
issuance of a GIDEP alert, problem advisory or major quality/reliability problem on their
products utilizing the test methods on the attached enclosure. Failure to provide prior
notification may be grounds for removal from DLA Land and Maritime’s Commercial Lab
Suitability Listing.
This commercial laboratory suitability is subject to the policies, procedures, and
conditions of the Defense Standardization Program, as published in the manual DoD 4120.24-M,
SD-6, and VQ booklet, DLA Land and Maritime-VQ Laboratory Suitability Information.
This commercial laboratory suitability is valid until withdrawn by DLA Land and
Maritime. Any deviation to the test method or condition(s) listed herein must be approved by the
Qualifying Activity.
If you have any questions, please contact Mr. Puhalsky at (614) 692-2458.
Sincerely,
Digitally signed by
KOLONCHUK.RAYMOND.L.JR.1230207093
DN: c=US, o=U.S. Government, ou=DoD, ou=PKI,
ou=DLA,
cn=KOLONCHUK.RAYMOND.L.JR.1230207093
Date: 2016.01.13 08:38:51 -05'00'
RAYMOND KOLONCHUK
Chief
Electronic Devices Branch
Enclosure
cc:
DLA Land and Maritime-VQC (Scott Thomas)
Visit us on the web at: http://www.dscc.dla.mil/offices/sourcing_and_qualification/
Enclosure to DLA Land and Maritime-VQ (VQC-16-030037)
TEST
SPECIFICATION
Remarking & Resurfacing
AS6081/Table 1 A3
Radiological (X-Ray) Inspection
AS6081/Table 1 A4
Lead Finish Evaluation (XRF or
EDS/EDX)
Delid/Decapsulation Internal Analysis
(destructive)
Electrical Testing
AS6081/Table 1 A5
AS6081/Table 1 A6
Criteria and Provisions for
QTSL/3.1.3
MIL-STD-750: 3401, 3404,
4021, 4022
Download