the Preliminary Program

advertisement
TECHNICAL
PROGRAM
September 22, 2014
International Conference on Condition Monitoring and Diagnosis 2014 • 21
Monday, September 22, 2014
09:00-10:20 POSTER SESSION PE, PF, PG
See p.28
10:20-10:40 Coffee Break Lobby (2F)
10:40-11:00 Opening Ceremony
Grand Ballroom 1 (2F)
Opening Address
Congratulatory Remarks
Mr. Ho Yong Kim, President of The Korean Institute of Electrical Engineers (KIEE)
Mr. Kwan-sup Lee, Vice Minister, Ministry of Trade, Industry and Energy (MOTIE), Republic of Korea
Mr. Byung-Sook Kim, Executive Vice President & Chief Technology Officer, Korea Electric Power
Corporation (KEPCO)
11:00-11:50 Plenary Lecture 1
Grand Ballroom 1 (2F)
Condition Monitoring on Gas-Insulated Systems
Prof. Dr.-Ing. Uwe Schichler, Graz University of Technology, Austria
11:50-12:30 Plenary Lecture 2
Grand Ballroom 1 (2F)
The Need for Testing, Diagnostics and Failure Investigations of Power Cables in a Smart
Grid Era
Dr. Peter van der Wielen, DNV GL (formerly known as DNV KEMA), Netherlands
12:30-13:40 Lunch Tamna Hall (8F)
13:40-15:40 SESSION OB1 : Transformer & Liquid Insulation 1
Grand Ballroom 2 (2F)
Chair : Zhongdong Wang (The University of Manchester, UK)
Co-Chair : Moon Ho Kang (KEPCO, Republic of Korea)
OB1-01
R esearch Progress on Aging Estimation of Oil-paper Power Transformer Based on
Frequency Domain Spectroscopy Measurement
Guan-Jun Zhang* (Xi'an Jiaotong University, China), Xue-Zhou Wu, Fan Bai, Ming Dong, Ke Wang,
Huan-Chao Cheng, Jin-Zhong Li, Yong-Hui Deng
OB1-02
Comparison Between Electrical and UHF PD Measurement Concerning Calibration and
Sensitivity for Power Transformers
M. Siegel* (University of Stuttgart, Germany), S. Tenbohlen
OB1-03
Influences of the Measurement Frequency Bandwidth on PD Current Pulse Waveforms
and Emitted EM Waves in Mineral Oil with the SHF_PDPW System
Takuya Matsumoto* (Kyushu Institute of Technology, Japan), Minoru Fukuzaki, Shinya Ohtsuka
International Conference on Condition Monitoring and Diagnosis 2014 • 23
September 22, 2014
Prof. Ja-Yoon Koo, Chairman of CMD2014, Hanyang University
OB1-04
P rediction of Failure Probability of Oil-immersed Transformers Containing Moisture
Based on Accelerated Aging Experiments
K. Wu.* (Xi'an Jiaotong University, China), CH. Chen., BS. He., W. Cao
OB1-05
Challenges in Monitoring of HV Equipment
W. Koltunowicz* (OMICRON Energy Solutions GmbH, Germany), L.V. Badicu, A. Piccolo
September 22, 2014
OB1-06
Difference in Detected PD-emitted Electromagnetic Waves in Atmospheric Air and
Insulation Oil by Antenna Type
Yasuyuki Ohkura* (Kyushu Institute of Technology, Japan), Toshitake Umegane, Ryota Fuchi,
Shinya Ohtsuka, Akira Taguchi, Yosuke Hashimoto
13:40-15:40SESSION OA : Rotating Machine
Grand Ballroom 3 (2F)
Chair : Greg Stone (Iris Power - Qualitrol, Canada)
Co-Chair : Hee Dong Kim (KEPCO Research Institute, Republic of Korea)
OA-01
Results from On-line Turbine Generator Endwinding Vibration Monitoring
G.C. Stone* (Iris Power - Qualitrol, Canada), J. Letal, M. Sasic
OA-02
Insulation Diagnosis with Capacitive Slot Coupler for Large Rotating Machines
Yong Joo Kim* (KERI, Republic of Korea), Geun Ju Kim, Jung Il Kim, Hee Dong Kim
OA-03
A Bayesian Method for Wind Turbine Gearbox Condition Monitoring Using SCADA Data
Niya Chen* (ABB Corporate Research Center, China), Rongrong Yu, Yao Chen
OA-04
Basic Principle Using New Technology Applied to Electric Generators
Marius Cloutier* (VibroSystM Inc., Canada)
OA-05
Evaluation of Partial Discharge Failures on HV Apparatus Over a Wide Frequency
Saravanakumar Arumugam* (University of Rostock, Germany), Sergey Gorchakov, Thomas Schoenemann
OA-06
Application of Partial Discharge Measurement on High Voltage Motor by Magnetic Method
Kang-Chih Fan* (Taiwan Power Diagnostic Service Co., Ltd., Taiwan), Min-Yen Chiu, Chang-Hsing Lee,
Chen-Li Fan, Yu-Chih Lin
13:40-15:40SESSION OD1 : Cable & Solid Insulation 1
Grand Ballroom 4 (2F)
Chair : Yasuhiro Tanaka (Tokyo City University, Japan)
Co-Chair : Wansoo Nah (Sungkyunkwan University, Republic of Korea)
OD1-01
Condition Monitoring for Predictive Maintenance of Cables Insulated with FR-EPDM by
Frequency Domain Reflectometry
Yoshimichi Ohki* (Waseda University, Japan), Naoshi Hirai
OD1-02
Investigations on a Combined Resonance/VLF HV Test System - Partial Discharge (PD)
Characteristics at VLF and DAC Voltages
D. Götz* (SebaKMT GmbH, Germany), F. Petzold, H.T. Putter, H. Schlapp, S. Markalous
24 • CMD2014
OD1-03
O bservations of Space Charge Accumulation Processes to Electrical Breakdown in
Various Insulating Materials under High DC Stresses
Y. Tanaka* (Tokyo City University, Japan), T. Kato, K. Matsubara, S. Kawano, H. Suzuki, H. Miyake
OD1-04
P VC Degradation and Discharges Due to Water Ingress in LV Underground Power Cables
B. Kruizinga* (Electrical Energy Systems Group Eindhoven University of Technology, Netherlands),
P.A.A.F. Wouters, E.F. Steennis
OD1-05
Detection of Local Impedance Variation in Electric Power Cable via Time-Frequency
Domain Reflectometry
September 22, 2014
Yee-Jin Han* (Yonsei University, Republic of Korea), Chun-Ku Lee, Seung-Jin Chang, Chun-Kwon Lee,
Jin Bae Park, Yong-June Shin
OD1-06
Cable Thermal Loss of Life Due to Time Varying Load and Ambient Temperature: A Case
Study
Swati Sachan* (Glasgow Caledonian university, UK), Yanling Yuan, Fuqing Xia, Shunjin Shi, Chengke Zhou,
Geraint Bevan, Babakalli Alkali
15:40-16:00 Coffee Break Lobby (2F)
16:00-18:00SESSION OB2 : Transformer & Liquid Insulation 2
Grand Ballroom 2 (2F)
Chair : B. T. Phung (University of New South Wales, Australia)
Co-Chair : Changsun Park (Hyundai Heavy Industries Co., Ltd., Republic of Korea)
OB2-01
A Practical Solution to Distinguish the Transformer Winding Deformation from Insulation
Characteristic Impacts on FRA Spectrum
B. T. Phung* (University of New South Wales, Australia), Mehdi Bagheri, T. R. Blackburn
OB2-02
S tudy on Sweep Frequency Impedance Method for Detecting Transformer Winding
Deformation
Yong Liu* (Xi'an Jiaotong University, China), Shengchang Ji, Fan Yang, Xiaochen Liang, Wenlin He,
Xiang Sun, Wei Qiu
OB2-03
Investigation of Indicator Gas for Internal Fault on Silicone Oil-immersed Transformer
Ryota Kuriyama* (Mitsubishi Electric Corporation, Japan), Tsuyoshi Amimoto, Yoshio Kimura,
Fukutaro Kato, Shiki Hayamizu
OB2-04
Influence of DC Voltage Component Proportion on Discharge Defect Gas Generating
Characteristic of the Suspension Electrode Oil-paper Insulation under the Action of ACDC Composite Voltage
KwangHui An* (North China Electric Power University, China), Bo Qi, Chengrong Li, Miao Yu
OB2-05
Simulation of Terminal Condition and System Function Pair of Three Phase Transformers
Adopted During SFRA Measurements
Saravanakumar Arumugam* (University of Rostock, Germany), Holger Strate, Sergey Gorchakov,
Thomas Schoenemann
International Conference on Condition Monitoring and Diagnosis 2014 • 25
OB2-06
Testing of High Voltage Assets – An Overview of State-of-the-art Technologies for Testing
Transformers
A. Kraetge* (HIGHVOLT Prueftechnik Dresden GmbH, Germany)
16:00-18:00SESSION OC1 : Switchgear & Gas Insulation 1
Grand Ballroom 3 (2F)
September 22, 2014
Chair : Wojciech Koltunowicz (OMICRON Energy Solutions GmbH, Germany)
Co-Chair : Jongung Choi (LS Industrial Systems, Republic of Korea)
OC1-01
E ffect of the Protrusion Defect Location on Propagation Characteristics of Partial
Discharge Radiated UHF Signal in GIS with Three Phase Construction
Xiaohua Wang* (Xi'an Jiaotong University, China), Tianhui Li, Mingzhe Rong, Xi Li, Shuang Hao,
Dingxin Liu, Ying Zhang
OC1-02
Partial Discharge Position Tracking Method Using a GIS Partial Discharge Signal and
Arrival Time Difference
Mun-Gyu Choi* (KEPCO, Republic of Korea), Yong-Woo Park, Choung-ho Yoon, Soon-Tae Kim,
Guk-Tae Kim
OC1-03
UHF Partial Discharge Monitoring System in Service: Generating and Responding to PD Alarms
F. I. Cook* (DMS-Qualitrol, UK)
OC1-04
Itaipu GIS PDM System - The Need, the Choice, Implementation & Successfully Cases
Prevented
Carlos Deligi* (Qualitrol Company LLC, Brazil), M.Sc José Guilherme Rodrigues Filho
OC1-05
Application of Pulsed X-ray Induced Partial Discharge Diagnostics During Routine Testing
U. Riechert* (ABB Switzerland Ltd., Switzerland), D. Tehlar, G. Behrmann, L. G. Herrmann, S. Pancheshnyi
OC1-06
Performance Assessment of Aged Power Circuit Breaker in Transmission Network for
Replacement Management
Thanachart Thanasettgone* (Unipower Engineering Co., Ltd., Thailand), Thanapong Suwanasri,
Sarawut Wattanawongpitak, Cattareeya Suwanasri
16:00-18:00 SESSION OE : Overhead Line & Insulator
Grand Ballroom 4 (2F)
Chair : Dong il Lee (KEPCO Research Institute, Republic of Korea)
Co-Chair : Ayman H. El-Hag (American University of Sharjah, UAE)
OE-01
Condition Monitoring System for the Detection of Defects in Ceramic Insulators Based on
Their Radio Frequency (RF) Signatures
Shaharyar Anjum* (University of Waterloo, Canada), Shesha Jayaram, Ayman H. El-Hag, Ali Naderian
OE-02
Using the Gray Level Co-occurrence Matrix to Improve the Swedish Hydrophobicity Class
System
Ayman H. El-Hag* (American University of Sharjah, UAE), Ibrahim Jarrar, Khaled Assaleh
OE-03
Robot System on Fault Porcelain Insulators Detection on HVAC Transmission Lines
Feiran Li* (North China Electric Power University, China), Liang Zhong, Juan Jia, Rui Guo, Yangchun Cheng,
Tao Hu
26 • CMD2014
OE-04
Condition of High Voltage Composite Insulators Endangered by Brittle Fracture
Richárd Cselkó* (Budapest University of Technology and Economics, Hungary), Gábor Göcsei,
Bálint Németh, István Kiss
OE-05
U V and IR Inspection of UHVAC Transmission Line
Yunseog Lim* (KEPCO Research Institute, Republic of Korea), Kooyong Shin, Sangbeom Kim,
Younghong Kim, Heewon No, Dongil Lee
OE-06
C ondition Assessment of Power Transmission Equipment Based on Combination
Weighting Method and Fuzzy Theory
International Conference on Condition Monitoring and Diagnosis 2014 • 27
September 22, 2014
Yingjie Yan* (Shanghai Jiao Tong University, China), Gehao Sheng, Yadong Liu
POSTER PRESENTATION
09:00-10:20SESSION PE : Overhead Line & Insulator
Lobby (2F)
Chair : Bang Wook Lee (Hanyang University, Republic of Korea)
PE-01High Impedance Fault Detection Based on Wavelet Entropy
B. T. Phung* (University of New South Wales, Australia), Huwei Wu, Daming Zhang, Jichao Chen
September 22, 2014
PE-02The Research on Design Scheme of the Panoramic Information System of China Southern
Grid EHV Power Transmission Company
Jinwei Li* (CSG EHV Power Transmission Company, China), Yining Zhang, Yunhai Song, Jue He
PE-03Optical Measurement of Electric Field Distribution along Composite Insulator under DC
Voltage
Guo-Qiang Su* (Xi’an Jiaotong University, China), Hai-Bao Mu, Bai-Peng Song, Wen-Dong Li,
Yan Lang, Guan-Jun Zhang, Yi-Fan Liao
PE-04Corona Onset Characteristics of the 750-kV Transmission Line Conductors Based on
Ultraviolet Imaging
Zilai Qiu* (North China Electric Power University, China), Yunpeng Liu, Xing Liu, Yansong Li, Jianghai Geng
PE-05A Method to Locate the Flashover Tower of AC Transmission Line
Wenjun Zhou* (Wuhan University, China), Bin Cao, Shuai Yang, Jianhui Yu, Charles Qi Su
PE-06Assessment the Transformer DC Magnetic Bias Impact of Jinping-Suzhou HVDC Project
Wu Peng* (Jiangsu Electric Power Research Institute, China), Yu Chao, Lu Yuncai, Chen Na
PE-07A Distributed Fault Location Method for the Cable-Overhead Mixed Lines
Wen Shen* (Shanghai Jiao Tong University, China), Tianchen Yue, Yadong Liu, Gehao Sheng,
Qinglin Qian, Zongjie Liu, Xiuchen Jiang
PE-08Intelligent Transmission Lines
Song Yunhai* (China Southern Power Grid, China), Chen Yue, Jinwei Li, Chang An
PE-09Study on Lightning Fault Locating System of Transmission-lines Based on Mutual
Inducted Energy-extracting
Xinbo Huang* (Xi’an Polytechnic University, China), Bin Zhang, Jie Shi, Xiao-xiong Chen
PE-10The Study of Insulator Leakage Current Waveforms Frequency Characteristics in Fog
Environment
Chun-hua Fang* (Three Gorges University, China), Ling Zhao, Jian-guo Wang, Ya-dong Fan, Yi Zhou,
Zheng Kong, Dan-Feng Xu
PE-11The Transmission Line Conductor Sag Measurement Method Based on Aerial Image
Sequence
Xinbo Huang* (Xi’an Polytechnic University, China), Ye Zhang, Fei Zhang
28 • CMD2014
PE-12Study on the Influence Factors of Dielectric Barrier Corona Discharge Electrical
Characteristics
Chongxing Zhang* (Xi’an Jiaotong University, China), Ming Dong, Ming Ren, Zhigang Xiao,
Guanjun Zhang
PE-13Data Collection and Evaluation for Medium Voltage Overhead Lines
Richard Cselko* (Budapest University of Technology and Economics, Hungary), Balint Nemeth,
Sandor Szabo, Tibor Fazekas, David Balango, Gabor Mihaly Peter
PE-15Effects of Humidity and NOx to Partial Discharge Degradation of Epoxy Resin
Yoshiyasu Ehara* (Tokyo City University, Japan), Takaaki Ishii
PE-16Effect of Nano-filler on Resistance to Tracking and Hydrophobicity of PP/EPDM Blends
Noor Syazwani Mansor* (Universiti Sains Malaysia, Malaysia), M. Mariatti, M. Kamarol
PE-17Development Status of DC XLPE Cable in Korea
Soo-Bong Lee* (LS Cable & System Ltd., Republic of Korea), Tae-Ho Lee, Eui-Hwan Jung,
Yoon-Hyoung Kim, Hee-Chan Park, Sung-Yun Kim, Su-Kil Lee, Jin-Ho Nam, Seung-Ik Jeon,
Wan-Ki Park
PE-18
Electric Field Analysis of Three Phase AC Single Circuit and DC Bipolar Hybrid Transmission
Line Considering Conductor Arrangements
Jung Ho Kim* (Hanyang University, Republic of Korea), Jae Sang Hwang, Bang Wook Lee
PE-19Evaluation of Various Design Factors of HVDC Polymer Insulator Based on DC Electric
Field Analysis
Jae-Hong Koo* (Hanyang University, Republic of Korea), Jae-Kyu Seong, Bang Wook Lee
PE-20KEPCO Overhead Transmission Line Inspection System by Unmanned Helicopter
Won Kyo Lee* (KEPCO Research Institute, Republic of Korea), Chan Hyeong Park
PE-21Development of Condition Monitoring and Diagnosis System Based on IEC 61850 Using
the Multifunctional Sensors and IEDs for Extra High Voltage GIS
Ji-Hoon Lee* (KEPCO KDN Co., Ltd., Republic of Korea), Young-Jae Myung, Duck-Ki Seo, Hoon Lee
PE-22Some Problems With RIP-Insulated Bushings
S.Zhivodernikov* (Electrogridservice, Russian Federation), A.Ovsyannikov, V.Rusov
PE-23Theoretical Model of Applying Radiometry to Monitor Insulator Contamination
Yan Jiang* (Glasgow Caledonian University, UK), Scott G. McMeekin, Alistair J. Reid, Azam Nekahi,
Martin D. Judd, Alan Wilson
PE-24 Identification Method of Shielding Failure and Back Striking in Power Transmission Line
Kai-hua Jiang* (State Key Laboratory of Power Transmission Equipment & System Security and New
Technology, China), Shao-qing Chen, Han-yu Wang, Lin Du, Jian-ming Li
International Conference on Condition Monitoring and Diagnosis 2014 • 29
September 22, 2014
PE-14A New Method for Modelling and Calculating Dynamic Line Rating
David Balango* (Budapest University of Technology and Economics, Hungary), Balint Nemeth,
Richard Cselko, Gábor Gocsei
09:00-10:20 SESSION PF : Substation
Lobby (2F)
Chair : Bang Wook Lee (Hanyang University, Republic of Korea)
PF-25The Development of Distribution Network Transmission Line Fault Wave Record Device
Jiejie Dai* (ShangHai Jiao Tong University, China), Hui Song, Yadong Liu, Gehao Sheng, Yun Hu,
Xiuchen Jiang
September 22, 2014
PF-26Experimental Research on Lightning Transient Voltage in a Simulated Cable Collector of
Wind Power Plant
Liu Xuezhong* (Xi’an Jiaotong University, China), Zhao Dan, Zhang Tianlong, Shang Yuchen
PF-27Stochastic Stability of Power System with High Penetration of Wind Power Considering
Randomness of the State Matrix Coefficients
Jin Zong* (North China Electric Power Research Institute Co., Ltd., China), Kai Bai, Bo Yuan, Zhengpai Cui
PF-28An Equivalent Circuit Based On-line Motor Condition Monitoring System by Electrical
Signal Analysis
Cheng-Chien Kuo* (Saint John's University, Taipei), Hong-Chan Chang, Yu-Ming Jheng, Yu-Lung Huang
PF-29Resonant-Frequency Shift of Transfer Function of Real Transformer in Frequency
Response Analysis (FRA) by Artificial Abnormality of Winding
S. Miyazaki* (Central Research Institute of Electric Power Industry, Japan), Y. Mizutani, T. Okamoto,
O. Kato, Y. Hayashi, A. Taguchi
PF-30Apparatus and Diagnosis Method for Noise Elimination of Partial Discharge
Jung-Chul Seo* (KEPCO, Republic of Korea), Jae-Koon Kim, Sang-Man Sim, Eun-Soo Song
PF-31A Study on the Measurement of Polymer Insulator Pollution through Analysis of the
Optical Image
Chul-Bae Park* (KEPCO, Republic of Korea), Jung-Hyun Yun, Gyeong-Bae Won, Moon-Ho Kang,
Jae-Hwan Pi
PF-32Statistical Evaluation of Failure and Performance Analysis of Distribution Equipments
Done in 2013
M. H. Kang* (KEPCO, Republic of Korea), Y. W. Park, J. H. Yun, C. B. Park, J. H. Pi, T. H. Kwon
PF-33UHF Sensor Location Optimization for Partial Discharge Signals Detection Method
Mun Gyu Choi* (KEPCO, Republic of Korea), Yong Woo Park, Choung ho Yoon, Soon Tae Kim, Guk Tae Kim
PF-34Prediction of Equipment Maintenance Period through Risk Assessment of Thermal Power
Plants
Geewook Song* (KEPCO, Republic of Korea), Woosung Choi, Myungsoo Park, Yongchae Bae
PF-35Investigation on Field-Aged RTV-Coated Bushings and Silicone Rubber Insulators in the
Gulf Region
Ayman H. El-Hag* (American University of Sharjah, UAE), Refat Ghunem, Shesha Jayaram
30 • CMD2014
PF-36Evaluation of Alternative Insulation Failure Criterion to Assist Asset Management of Aged
Transformers
Z.D. Wang* (The University of Manchester, UK), B. Patel, P. Jarman
09:00-10:20 SESSION PG : Other Topics
Lobby (2F)
Chair : Bang Wook Lee (Hanyang University, Republic of Korea)
PG-37Risk Management of Power Equipment
U. Schichler* (Graz University of Technology, Austria), C. Sumereder
Shengtao Li* (Xi'an Jiaotong University, China), Yongjie Nie, Ni Zhao, Weiwang Wang
PG-39 S
tudy on the Factors Affecting the Bandwith of SMD Divider for High Voltage Nanosecond
Pulse Measurement
Zelai Sun* (North China Electric Power University, China), Chengrong Li, Panhui Guo, Min Chen,
Guoming Ma
PG-40Partial Discharge Image De-noising Method Based on Contourlet Transform
Jiabin Zhou* (State Grid Shandong Electric Power Company, China), Yufeng Chen, Wenbing Zhu,
Xiuming Du, Ju Tang, Xiaoxing Zhang
PG-41Feature Extraction and Optimization for Partial Discharge Diagnosis
Zhiguo Tang* (North China Electric Power University, China), Changbiao Liu, Liang Li, Liangen Zhang,
Chengrong Li
PG-42Measurement of Oil Wedge Partial Discharges under Impulse Voltage in Optoelectronic
Detection System
Yunpeng Liu* (North China Electric Power University, China), Jian Wang, Tao Zhao, Shiyan Li
PG-43Influence of Temperature on Deep Dielectric Charging in Low Density Polyethylene
Irradiated by Energetic Electrons
Guochang Li* (Xi’an Jiaotong University, China), Shengtao Li, Daomin Min, Wenfeng Liu, Liuqing Yang
PG-44Comparison of the Time-Frequency Algorithms for Analyzing Partial Discharge Pulse in
GIS
Xiao Zhi-Gang* (Xi’an Jiaotong University, China), Dong Ming, Ren Ming, Bi Jian-Gang, Yuan Shuai
PG-45The Research of Power Output Smoothing in Grid-friendly Wind Farm Based on Leastsquare Polynomial Fitting Method
Yu Liu* (North China Electric Power Research Institute Co., Ltd., China), Kai Bai, Hui Liu, Shaoyu Liu,
Yuhui Wu, Hao Chen, Zhi Li, Si Zhu
PG-46Analysis of Sub-synchronous Resonance in Wind Power Plants Based on Data from
Phasor Measurement Unit
Yunhong Li* (North China Electric Power Research Institute Co., Ltd., China), Shaoyu Liu, Hui Liu,
Yu Li, Jingbo Liu
International Conference on Condition Monitoring and Diagnosis 2014 • 31
September 22, 2014
PG-38Effect of Fluorination on Surface Flashover Characteristics of LDPE in Vacuum
PG-47Modeling and Parameter Identification of Wind Turbine Based on Low Voltage Ride
through Test Data
Lin-lin Wu* (North China Electric Power Research Institute Co., Ltd., China), Hui Liu, Jia-an Zhang,
Jing-bo Liu, Hao-jing Wang
PG-48Measurement of Space Charge Distribution Accumulated in Insulating Material of
Enameled Wire under Square Voltage Application
September 22, 2014
Kazuki Abe* (Tokyo City University, Japan), Arata Naoumi, Hiroaki Miyake, Yasuhiro Tanaka,
Takashi Maeno
PG-49Improvement of Sensor for Electromagnetic Measurement System Using Infrared 2-D
Lock-in Amplifier
Masahiro Konomi* (Tokyo City University, Japan), Yasuhiro Tanaka, Takashi Maeno
PG-50Research on Reliability Verification Analysis Targeting Diagnostic Cases by Outsourcing
Using Thermal Imaging
Kwang-Heung Jang* (KEPCO, Republic of Korea), Yong-Woo Park, Byoun-Hun Jung, So-won Jee,
Doc-Jun Byun
PG-51The Condition Monitoring and Diagnosis of the Distribution Line Connected to EV
Charging Stations Based on IT Technology
Taek Ho Song* (KEPCO Research Institute, Republic of Korea), Seung Ho Han, Sang Ok Kim
PG-52A Flexible Rotor Fault Diagnosis System Based on Feature Estimation Classification
Method
Donghwan Kim* (KEPCO Research Institute, Republic of Korea), Seokman Sohn, JeongHoon Kim,
Yeonwhan Kim, Yongchae Bae
PG-53A Study on the Setting of the OLTC for Optimal Voltage and Minimum Operation
Won Nam-Koong* (KEPCO Research Institute, Republic of Korea), Soung-Ouk Heo, Moon-Jong Jang,
Sung-Woo Lee, Geum-Young Jung
PG-54Some Possibility of Constructing of the PD Processes Quasi-Deterministic Model
N. V. Kinsht* (Institute of Automation & Control Processes of Far-Eastern Branch of RAS IACP
FEBRAS, Russian Federation), N. N. Petrunko
PG-55Designed and Construction the Spark Tester by DC High Voltage 15 kV Rated
S.Nedphokaew* (Rajamangala University Of Technology Phra Nakhon, Thailand)
PG-56Different Concept of On-line Partial Discharge Monitoring System in Industries
Chang-Hsing Lee* (Power Diagnostic Service Co., Ltd., Taiwan), Min-Yen Chiu, Chih-Hsien Huang,
Shih-Shong Yen
32 • CMD2014
TECHNICAL
PROGRAM
September 23, 2014
International Conference on Condition Monitoring and Diagnosis 2014 • 33
Tuesday, September 23, 2014
09:00-11:00 SESSION OB3 : Transformer & Liquid Insulation 3
Grand Ballroom 2 (2F)
Chair : Seok Bok Yeol (Hyundai Heavy Industries Co., Ltd., Republic of Korea)
Co-Chair : Lukasz Chmura (Delft University of Technology, Netherlands)
OB3-01
How to Make Use of Transformer Heat Run Test Results — Review on Thermal Parameter
Derivation Methods
Z. D. Wang* (University of Manchester, UK), Yuan Gao, Darren Jones
OB3-02
New Diagnostic Tools for High Voltage Bushings Considering Temperature Dependency
Markus Puetter* (OMICRON electronics, Austria), Inho Hong, Martin Anglhuber, Michael Kueger,
Maik Koch
OB3-03
Trends in Supervision of Transformer Accessories and Management
U. Kaltenborn* (Maschinenfabrik Reinhausen GmbH, Germany), T. Krueger, A. Kraemer
OB3-04
On-site Calibration of Voltage Transformers
OB3-05
A New Approach for In-situ Calibration of Voltage Transformers
M. Freiburg* (TU Dortmund University, Germany), F. Predl, M. Krueger, F. Jenau
09:00-11:00 SESSION OC2 : Switchgear & Gas Insulation 2
Grand Ballroom 3 (2F)
Chair : Uwe Schichler (Graz University of Technology, Austria)
Co-Chair : Xiaohua Wang (Xi'an Jiaotong University, China)
OC2-01
Direct and Accurate Measurement of the Overlapping Time in GCB Applications
Y. Maret* (Corporate Research ABB Schweiz AG, Switzerland), M. Zlatanski, S. Marinkovic,
G. L. Madonna, M. Hochlehnert
OC2-02
Development of an Active Three-dimensional SF6 Leakage Concentration Distribution
Monitoring System Based on an Infrared Sensing Technology
Yi Yin* (Shanghai Jiao Tong University, China), Peiliang Zeng, Wensheng Zheng, Jian Shu,
Xiangmao Cheng, Qiaohua Wang
OC2-03
Study on Diagnostic Method of SF6 Gas Pressure and Leakage in GIS
C. S. Park* (Hyundai Heavy Industries Co., Ltd., Republic of Korea), J. B. Lee, J. Lee, J. H. Kim
OC2-04
Influence of Repeated Breakdown Processes on VFTO in 252kV GIS
Linzhi Yao* (North China Electric Power University, China), Huamao Zhan, Shaofeng Duan,
Chengrong Li, Lin Zhao
International Conference on Condition Monitoring and Diagnosis 2014 • 35
September 23, 2014
Seokhoon Hong* (OMICRON electronics Korea Inc., Republic of Korea), Florian Predl, Michael Freiburg,
Michael Krueger
OC2-05
Performance of a Novel SF 6 Concentration Sensor for Gas-insulated Electrical Apparatus
under Field Conditions
Th. A. Paul* (ABB Corporate Research, Switzerland), M. Porus, B. Galletti, A. Kramer
OC2-06
Study of Fault Diagnosis of High Voltage Circuit Breaker Based on SOM Method
Jianxiang Sun* (Southwest Jiaotong University, China), Xukun Chen, Xuesong Ni, Guangning Wu,
Baojiang Cao
09:00-11:00SESSION OF : Substation
Grand Ballroom 4 (2F)
Chair : Guan-jun Zhang (Xi'an Jiaotong University, China)
Co-Chair : Jae Ryong Jung (Hyosung Corporation, Republic of Korea)
OF-01
E xperience of On-line Partial Discharge Monitoring on a Wide-area Medium Voltage Network
Ravish P.Y. Mehairjan* (Delft University of Technology, Netherlands), Dhiradj Djairam, Sander Meijer,
Peter Zonneveld, Johan J. Smit
OF-02
A State Evaluation Technique Based on the Security Objects in Power System Networks
September 23, 2014
Chung-Hyo Kim* (KEPCO, Republic of Korea), Moon-Seok Choi, Seong-Ho Ju, Yong-Hun Lim,
Seo-Hee Jeong, Kyung-Seok Jeon
OF-03
S tudy on Solution and Integrated System for Regional and Precise Partial Discharge
Detection and Location in Substation
Tang Lin* (Shanghai Jiao Tong University, China), Hu Yue, Zhang Qianqian, Wang Hongbin, Jiang Xiuchen
OF-04
Study on Detection Signal Identification of Prototype Online Partial Discharge Monitoring
and Diagnosis System in High Voltage Electric Equipment
Yuki Tai* (Kyushu Institute of Technology, Japan), Nobuki Yasukochi, Asuka Suizu, Naohiro Yamamura
OF-05
Substation Surveillance Using RFI and Complementary EMI Detection Techniques
H.O. Kristiansen* (Doble TransiNor AS, Norway), A. Nesbitt, B.G. Stewart, S.G. McMeekin, S. Kråkenes
OF-06
Development and Application of Wind Farm Operation State Monitoring System Based on
PMU Data
Huimin He* (North China Electric Power Research, China), Linlin Wu, Haojing Wang, Hui Liu
11:00-11:20 Coffee Break 11:20-12:00 Plenary Lecture 3
Lobby (2F)
Grand Ballroom 1 (2F)
A Novel On-line Insulation Diagnosis Technique for Large Rotating Machine
Dr. Yong Joo Kim, Korea Electrotechnology Research Institute (KERI), Republic of Korea
12:30-17:30 Technical Tour
36 • CMD2014
TECHNICAL
PROGRAM
September 24, 2014
International Conference on Condition Monitoring and Diagnosis 2014 • 37
Wednesday, September 24, 2014
08:50-10:10 POSTER SESSION PA, PC, PD See p.43
10:10-10:30 Coffee Break
Lobby (2F)
10:30-12:30 SESSION OB4 : Transformer & Liquid Insulation 4
Grand Ballroom 2 (2F)
Chair : Michael Muhr (Test Institution of High Voltage Engineering Graz Ltd. (VAH Graz Ltd.), Austria)
Co-Chair : A. Abu-Siada (Curtin University, Australia)
OB4-01
Application of Digital Image Processing to Diagnose Transformer Winding Deformation
Using FRA Polar Plot
A. Abu-Siada* (Curtin University, Australia), O. Aljohani, S. Islam
OB4-02
A Reliable Health Assessment of Power Equipment through Diagnostic Studies of
Dielectric Fluid
K. Baburao* (Raj Petro Specialities Pvt. Ltd., India), Nalin Nanavati
OB4-03
Partial Discharge Inception and Development Characteristics of Oil-paper Insulation
under Different Voltage Types
Wei Zhen* (North China Electric Power University, China), Bo Qi, Peng Zhang, Gurizo Joseph, Miao Yu,
Chengrong Li
OB4-04
Pulse Signal Transfer Characteristics of Insulating Transformer with Its Secondary Side
Open
Wansoo Nah* (Sungkyunkwan University, Republic of Korea), Sungjun Kim, Jonghyeon Kim, Taeho Kim,
Bo Pu
OB4-06
Monitoring of Epoxy Resin's Internal Temperature Using FBG Sensors with Special Package
Tao Zhang* (Xi'an Jiaotong University, China), Haoran Wang, Chen Chen, Zongren Peng, Hui Ding
10:30-12:30 SESSION OG : Other Topics
Grand Ballroom 3 (2F)
Chair : June Ho Lee (Hoseo University, Republic of Korea)
Co-Chair : Peng Song (North China Electric Power Research Institute Co., Ltd., China)
OG-01
Online-monitoring and Efficiency Evaluation System for Grid-connected Photovoltaic
Generation Station
Peng Song* (North China Electrical Power Research Institute Co. Ltd., China), Li Zhi, Kai Bai, Hui Liu,
Jin Zong, Na Li
OG-02
The Effect of Water on the Service Ability of Oil-filled 10 kV Switchgear
Łukasz Chmura* (Delft University of Technology, Netherlands), V.L. Kanas, P.H.F. Morshuis, P. van Nes,
J.J. Smit, Anna Peksa
International Conference on Condition Monitoring and Diagnosis 2014 • 39
September 24, 2014
OB4-05
Assessing Transformer Reliability Using Post-Mortem Data and Health Indices
Z.D. Wang* (The University of Manchester, UK), B. Patel, J.V. Milanovic, P. Jarman
OG-03
A Lithium Battery Energy Storage System State Evaluation Method
Na Li* (North China Electric Power Research Institute Co., Ltd., China), Kai Bai, Hao Chen, Hu Niu,
Wen-qi Dong
OG-04
F lashover Voltage Properties between Foil Electrodes Formed on the Printed Wiring
Board under the ESD Test
Tomohito Kamo* (Kyushu Institute of Technology, Japan), Sho Iwai, Masashi Sonoda, Shinya Ohtsuka
OG-05
Dynamic Response Performance Evaluation of Dynamic Reactive Power Compensation
Equipment in Large Scale Wind Power System
Hao-jing Wang* (North China Electric Power Research Institute Co.,Ltd., China), Hui Liu, Yu-hui Wu,
Jing-bo Liu
OG-06
Research on Condition Evaluation Method of New-energy Generation Equipment Based
on Reliability and Generation Performance Index
Peng Song* (North China Electric Power Research Institute Co., Ltd., China), Kai Bai, Na Li, Zhi Li,
Hanmin Liu, Si Zhu
10:30-12:30SESSION OD2 : Cable & Solid Insulation 2
Grand Ballroom 4 (2F)
Chair : Shengtao Li (Xi’an Jiaotong University, China)
Co-Chair : Soo-Bong Lee (LS Cable & System Ltd., Republic of Korea)
OD2-01
V iability of Partial Discharge and Dielectric Dissipation Factor Testing with VLF
Excitation
T. R. Blackburn* (University of New South Wales, Australia), B. T. Phung
September 24, 2014
OD2-02
An Algorithm Development for Finding PD Sources Located in 154kV XLPE Power Cable
System
Won Choi* (Hanyang University, Republic of Korea), In-Jin Seo, Young-Jo Lee, Seong-Duk Mun,
Ja-Yoon Koo, Jeong-Tae Kim
OD2-03
C omparison of Partial Discharge Behavior with Alternating Current and Damped
Alternating Current at Different Frequencies
M. Wild* (University of Stuttgart, Germany), S. Tenbohlen, B. Quak
OD2-04
OWTS Diagnosis for Partial Discharge on Distribution Power Cable from Case Study
Dowon Kim* (Global Testing Services, Australia)
OD2-05
Study of A Partial Discharge Localization on A 110kV GIS Cable Sealing End
Min Chen* (SE Technology Limited, Hong Kong), Koji Urano, Teng-biao Chen
OD2-06
Smart Cable Guard for PD-online Monitoring of MV Underground Power Cables in Stedin’s
Network
Peter C.J.M. van der Wielen* (DNV GL Energy, Netherlands), Fred Steennis, Peter Buys,
Ravish P.Y. Mehairjan
12:30-13:30 Lunch 40 • CMD2014
The Blue (2F)
13:30-14:50 POSTER SESSION PB See p.48
14:50-15:10 Coffee Break
Lobby (2F)
15:10-17:10 SESSION OB5 : Transformer & Liquid Insulation 5
Grand Ballroom 2 (2F)
Chair : Se-Hee Lee (Kyungbook National University, Republic of Korea)
Co-Chair : Bartlomiej Dolata (ALSTOM Grid GmbH, Germany)
OB5-01
The Influence of Non-homogeneity of Life-data on the Validity of Statistical Analysis
Łukasz Chmura* (Delft University of Technology, Netherlands), P.H.F. Morshuis, J.J. Smit, Anton Janssen
OB5-02
An Approach to CT Aging Period Assessment Using Health Index
Bi-jun Chen* (Chongqing University, China), Feng-bo Tao, Cheng-bo Hu, Yun-cai Lu, You-yuan Wang
OB5-03
Analysis of Transient Switching Events in Substations
J. Plesch* (Graz University of Technology, Austria), S. Pack, G. Achleitner, U. Schichler
OB5-04
Investigation and Application of an Experimental Transformer Model for Fault Diagnosis
Yi Yin* (Shanghai Jiao Tong University, China), Hongliang Liu, Qian Zhang, Jin Pan, Hui Fan, Shuguo Gao,
Zhuoran Wang, Zhihao Wang
OB5-05
Investigating the Phenomenon of High Rise of CO and CO 2 in Shunt Reactors
Bhaskar D. Malpure* (Crompton Greaves Ltd., India), K. Baburao
OB5-06
Transformer Condition Assessment with an Integrated Test Van
D. Denissov* (Megger GmbH, Germany), A. P. Aleev
15:10-17:10 SESSION OC3 : Switchgear & Gas Insulation 3
Grand Ballroom 3 (2F)
OC3-01
PD Behaviour at AC and DC Voltage
R. Haller* (University of West Bohemia, Czech Republic), J.Pihera, M. Svoboda, P. Mraz
OC3-02
Characteristics of Partial Discharge Depending on SF6 Pressure in High Voltage Direct
Current
Sun-Jae Kim* (Korea Maritime and Ocean University, Republic of Korea), Hyang-Eun Jo, Gi-Woo Jeong,
Gyung-Suk Kil, Jae Ryong Jung
OC3-03
Investigation of Heavy Gas Diffusion Model and Its Application on SF6 Concentration
Distribution Detection in GIS Indoor Substation
Yi Yin* (Shanghai Jiao Tong University, China), Kemaio Cheng, Jianxin Chen, Tianquan Wu, Wenrui Wu,
Zhihao Wang
OC3-04
Comparison of PD Measurement Method by the IEC60270 and Acoustic Emission in a Pilot
GIS Chamber
Gi-Woo Jeong* (Korea Maritime and Ocean University, Republic of Korea), Sun-Jae Kim, Hyang-Eun Jo,
Gyung-Suk Kil, Sung-Wook Kim
International Conference on Condition Monitoring and Diagnosis 2014 • 41
September 24, 2014
Chair : Jung-Bae Kim (Hyosung Corporation, Republic of Korea)
Co-Chair : Jin Ho Kim (Hyosung Corporation, Republic of Korea)
OC3-05
Comparison of Partial Discharge Pattern in SF6 and N2 Gas
Hyang-Eun Jo* (Korea Maritime and Ocean University, Republic of Korea), Sun-Jae Kim, Gi-Woo Jeong,
Gyung-Suk Kil, Young-Min Kim
15:10-17:10 SESSION OB6 : Transformer & Liquid Insulation 6
Grand Ballroom 4 (2F)
Chair : Stefan Tenbohlen (University of Stuttgart, Germany)
Co-Chair : Hwang Dong Seo (Hyosung Corporation, Republic of Korea)
OB6-01
Study of Power Transformer Risk Cost Evaluation And Maintenance Strategy Based upon
Matter-element Extension and Cloud Model
Yun Liang* (Chongqing University, China), Chengbo Hu, Fengbo Tao, Jinggang Yang, Youyuan Wang
OB6-02
Planning Maintenance Strategy for Power Apparatus and T&D System with Intelligent
Grid Management System (IGMS)
H. Kojima* (Nagoya University, Japan), K. Fukaya, M. Hanai, N. Hayakawa, H. Okubo
OB6-03
E xperiences with the Introduction of Online Condition Monitoring in Asset Management
for Distribution Networks
Ravish P.Y. Mehairjan* (Delft University of Technology/Stedin B. V., Netherlands), Fred Steennis,
Gian Carlo Montanari, Peter Morshuis, Dhiradj Djairam, Johan J. Smit
OB6-04
Condition Monitoring Framework for Maintenance Management
Johan J. Smit* (Delft University of Technology/Stedin B. V., Netherlands), Dhiradj Djairam,
Martin van Hattem, Ravish P.Y. Mehairjan
OB6-05
Lifetime Management of Power Transformers - A Romanian Experience
September 24, 2014
C. Moldoveanu* (S.C. Nova Industrial S.A., Romania), V. Ursianu, M. Avramescu, I. Ionita, F. Goni,
C.D. Lungu, M. Florea, I. Hategan, M. Budan
OB6-06
Asset Management of Bushings: Using Online Monitoring
T. McGrail* (Doble Engineering Company, USA), K. Elkinson
17:10-17:40 Closing Ceremony
42 • CMD2014
Grand Ballroom 1 (2F)
POSTER PRESENTATION
08:50-10:10 SESSION PA : Rotating Machine
Lobby (2F)
Chair : Yong Moo Chang (Hanyang University, Republic of Korea)
PA-01Effect of Direct Fluorination on Surface Partial Discharge Characteristics of Magnet Wire
B. X. Du* (Tianjin University, China), Heng. Du
PA-02Simultaneous Dissipation Factor and Partial Discharge Measurement on Rotating
Machines – Limitations, Challenges, Solutions
P. Mraz* (Haefely Test AG, Switzerland), P. Treyer, S. Gonzalez, S. Azer
PA-03Voltage and Frequency Accelerated Ageing Studies on Epoxy Mica Stator Winding
Insulation of High Voltage Machines
B. Nageshwar Rao* (Central Power Research Institute, India), J. Sundara Rajan
PA-04A Fault Diagnostic Method for Electric Motors Using a Neural Network Algorithm
C. H. Shon* (Korea Electrotechnology Research Institute(KERI), Republic of Korea), Y. W. Youn,
D. H. Hwang, J. H. Sun, D. S. Kang
PA-05Observation of Degradation of FR-EPDM by Scanning Probe Microscopy
Takayuki Niki* (Waseda University, Japan), Naoshi Hirai, Yoshimichi Ohki
08:50-10:10SESSION PC : Switchgear & Gas Insulation
Lobby (2F)
Chair : Yong Moo Chang (Hanyang University, Republic of Korea)
PC-06 Research on Infrared On-line Monitoring Technology for GIS Contacts Temperature
Jinyuan Xing* (North China Electric Power University, China), Haoxi Cong, Hao Wu, Yang Liu,
Zhicheng Zhou, Yongyong Jia
PC-08The Characteristic of Oil-paper Insulation System under High-frequency Voltage Based
on DGA
Rui Yang* (North China Electric Power University, China), Xuelei Wang, Qingmin Li, Ying Zhang, Shuai Han,
Shuguo Gao, Hui Fan
PC-09Possibility of Circuit Breaker Three-phase Un-synchronization Time Online Monitoring by
RF Method
Wei Wang* (North China Electric Power University, China), Yuxiao Zhang, Xingquan Huang,
Chengrong Li
PC-10The Correlation between the Coil Current and the Operation Process of a High Voltage
Circuit Breaker
Yonggang Guan* (Tsinghua University, China), Xinxia Peng, Beiyang Liu, Changyu Bai, Weidong Liu
International Conference on Condition Monitoring and Diagnosis 2014 • 43
September 24, 2014
PC-07Calculating the Sensitivity of UHF Sensors for Partial Discharge Detection Using Finite
Integration Technique
Xiaoxin Chen* (Shanghai Jiao Tong University, China), Yong Qian, Yuyan Man, Xiaoguang Xi,
Gehao Sheng, Xiuchen Jiang
PC-11Analysis on Time-Frequency Distribution Characteristics of Vibration in High Voltage
Circuit Breakers Based on Morlet Wavelet Transform
Cheng Tang* (Pinggao Group Co., Ltd., China), Junhui Wu, Liucheng Hao, Zhiyong Yang, Yonggang Guan,
Shutong Gao
PC-12The Simulation Study of PD Electromagnetic Wave Propagation Characteristics in Linear
Type GIS Model
Li Junhao* (Xi’an Jiaotong University, China), Gao Yuan, Hou Xinyu, Chen Jun
PC-13
Influence of Spacer on Propagation and Leakage Properties of PD-induced Electromagnetic
Wave in GIS
Ming-Xiao Zhu* (Xi'an Jiaotong University, China), Hai-Bao Mu, Yuan Li, Xian-Jun Shao, Jun-Bo Deng,
Guan-Jun Zhang
PC-14Research on GIS Temperature Monitoring Method Based on Surface Acoustic Wave
Technology
Guoming Ma* (North China Electric Power University, China), Xuewei Chen, Dingping Luo, Chengrong Li,
Jun Jiang, Qifu Lu, Zengbin Wang
PC-15 Research on Very Fast Transient Overvoltage During Switching of Disconnector in 550kV GIS
Huamao Zhan* (North China Electric Power University, China), Zhao Lin, Shaofeng Duan, Chengrong Li,
Linzhi Yao
PC-16Coupling Characteristics of Loop Sensors Used for Detecting Partial Discharges in GIS
Hermawan* (Institut Teknologi Bandung, Indonesia), Chengrong Li, Suwarno, Shusheng Zheng,
Meng He, Wiweko Setya Budhi
PC-17Influence of Partial Discharge Source Position and Direction on Sensitivity of UHF Sensors
September 24, 2014
Wiweko Setya Budhi* (Institut Teknologi Bandung, Indonesia), Chengrong Li, Suwarno, Shusheng Zheng,
Meng He, Hermawan
PC-18Lightning Impulse Breakdown Characteristic of Dry-Air/Silicone Rubber Hybrid
Insulation in Rod-Plane Electrode
K-J Lim* (Hyundai Heavy Industries Co., Ltd., Republic of Korea), J-H Kwon, J-S Park, Y-M Kim
PC-19A Case Study of Analyzing Partial Discharge on GIS for Identifying the Origin and
Eliminating Noise
Inkyu Hwang* (KEPCO, Republic of Korea)
PC-20Case Studies on Diagnostic Techniques for 25.8kV Gas Insulated (SF6) Load Breaker
Switchgear Failure Prevention Optimization of Distribution System
Kui-Jun Kang* (KEPCO, Republic of Korea), Jong-Myoung Shim, Sung-Hwan Bae, Tae-Ho Kwon,
Sung-GU Gi, Ju-Hyun UM
PC-21On-line SF6 Monitoring – Breaking Paradigms
Carlos Deligi* (Qualitrol Company LLC, UK)
44 • CMD2014
08:50-10:10SESSION PD : Cable & Solid Insulation
Lobby (2F)
Chair : Yong Moo Chang (Hanyang University, Republic of Korea)
PD-22Research on the Insulation Design of High Voltage Solid-State Switch
Dingping Luo* (North China Electric Power University, China), Xuewei Chen, Jun Jiang, Guoming Ma,
Chengrong Li, Qingmin Li
PD-23Effect of nano-fillers on the aging parameter of XLPE under DC voltage
Kai Wu* (Xi’an Jiaotong University, China), Ya Wang, Zepeng Lv, Xia Wang, Demin Tu
PD-24Optimal Analysis for Ampacity of 10kV XLPE Power Cables for Urban Distribution
Networks
Yan-ling Zheng* (Baoji University of Arts and Sciences, China)
PD-25The Development of Partial Discharge Characteristics in 10kV Cable Accessories
Hui Ni* (Xi'an Jiaotong University, China), Yuan Li, Yoga Napitupulu, Junbo Deng, Haibao Mu,
Suwarno, Guanjun Zhang
PD-26Development of Ultra-low Frequency and High Amplitude Signal Generator for FDS Test of
Oil-Paper Insulation
Wen-Dong Li* (Xi’an Jiaotong University, China), Bin Wei, Fan Bai, Xiao-Jun Tang, Guan-Jun Zhang,
Ke Wang, Huan-Chao Cheng
PD-27Effect of Conductivity Property on Electric Field Distribution in HVDC Extruded Cable
Insulation
Yi Yin* (Shanghai Jiao Tong University, China), Li Lan, Jiandong Wu, Shuqi Li, Zhe Li
PD-28Partial Discharge Localization System of XLPE Cable Based on GPS Synchronization
Hui Song* (Shanghai Jiao Tong University, China), Jie-jie Dai, Yong Qian, Gehao Sheng, Xiuchen Jiang
PD-30Effects of Defects on Partial Discharge of Polyimide Thin Film under LN2 Temperature
B. X. Du* (Tianjin University, China), Y. Q. Xing
PD-31Influence of Curing Conditions on the Mechanical Properties of Fiberglass-reinforced
Epoxy Composite
M. Bartunkova* (University of West Bohemia, Czech Republic), R. Polansky, M. Cermak, P. Prosr
PD-32Method for On-site Testing of High Voltage Cables Using Continuous AC Voltages
M. Jochim* (HIGHVOLT Prüftechnik Dresden GmbH, Germany)
PD-33On-site Testing and Diagnosis of Distribution and Transmission Power Cables Using
Damped AC Voltages
M. Wild* (University of Stuttgart, Germany), E. Gulski, R. Jongen, S. Tenbohlen
International Conference on Condition Monitoring and Diagnosis 2014 • 45
September 24, 2014
PD-29Space Charge Characteristics in Oil-impregnated Paper after Partial Discharge Aging
Guan-Jun Zhang* (Xi’an Jiaotong University, China), Yan-Hui Wei, Bin Wei, Wei-Zheng Zhang,
Zhi-Min Li, Hai-Bao Mu, Si-Xiang Zhao, Yuan Li
PD-34Useful Application of PD Pulse Generator in PD Measurement for Cable Circuit
Min Chen* (SE Technology Limited, China), Koji Urano, Teng-biao Chen
PD-35Pattern Analysis of Partial Discharges in XLPE Cable Insulation with Artificial Defects
Yoga Napitupulu* (Institut Teknologi Bandung, Indonesia), Hui Ni, Rudiana Nurhadian, Jun-Bo Deng,
Hai-Bao Mu, Suwarno, Guan-Jun Zhang
PD-36Expectation-Maximization Method for Analyzing Incomplete Failure Data from 10kV
Cables
Q. Zhuang* (Delft University of Technology, Netherlands), N. Steentjes, R. Mehairjan, J. Smit
PD-37Combined Application of Diagnostics Tools for MV Underground Cables
Tobias Neier* (BAUR Prüf- und Messtechnik GmbH, Austria), Martin Jenny
PD-38Considerations on Long-term Degradation Characteristics of Nano-composite HVDC
XLPE Cable Insulation Materials Using Mutiple Degradations
Donguk Kim* (Daejin University, Republic of Korea), Gijin Nam, Woobin Kim, Jeongtae Kim
PD-39A Study of Analyzing VLF(Very Low Frequency) Tan δ of Medium Voltage Cable
Sung-min Kim* (KEPCO, Republic of Korea), Dongsub Kim, Si sik Jeon, Jangseob Lim
PD-40Overview of Condition Monitoring and Diagnosis System for Power Tunnel and Extra High
Voltage Underground Cable in Based on IEC 61850
Ji-Hoon Lee* (KEPCO KDN Co., Ltd., Republic of Korea), Young-Jae Myung, Duck-Ki Seo, Hoon Lee
September 24, 2014
PD-41Study on Measurement of Dissipation Current in XLPE Cables
S. T. Park* (LS Cable & System Ltd., Republic of Korea), D. J. Kim, K. H. Jon, J. N. Kim, S. I. Jeon,
W. K. Park
PD-42The Way of Economical Management for the Underground Distribution System Based on
Diagnosis in KEPCO
Sung-min Kim* (KEPCO, Republic of Korea), Dongsub Kim, Si sik Jeon, Tobias Neier
PD-43Space Charge Formations and Electrical Conductivities Characteristics of Several XLPEs
as a Function of Time
Hyun-Jung Jung* (LS Cable & System Ltd., Republic of Korea), Jin-Ho Nam, Yi-Seul Yang, Tae-Hyun Lee,
Ik-Hyun Ryu, Wan-Ki Park
PD-44A New Noise Elimination Method for PD Diagnosis of Underground Transmission Cable
Terminal Joints
Taein Jang* (KEPCO, Republic of Korea), Hungsok Park, Jiwon Kang, Jin Kim, Taehyueng Rho
PD-45The Analysis of Electrical Tree in MV Cable
Chong-eun Cho* (KEPCO, Republic of Korea), Yong-woo Park, Jung-hyun Yun
PD-46A Study on DC Breakdown and Partial Discharge Characteristics for PPLP Insulation
under Cryogenic Temperature
Jisub Yoon* (Daejin University, Republic of Korea), Donguk Kim, Gijin Nam, Jeongtae Kim
46 • CMD2014
PD-47A Study on the Creepage Characteristics of Indoor Insulation Material Considering
Humidity and Salt Contamination
H.J.Jeong* (Hanyang University, Republic of Korea), Y.J.Lee, I.J.Seo, J.Y.Koo, Y.M. Kim, J.Y.Kim, B.Y. Soek
PD-48Parameter Extraction of Coaxial Cable by De-embedding SMA Connectors
Kwangho Kim* (Sungkyunkwan University, China), Soojung Ryu, Seungje Song, Bo Pu, Chanwoo Lim,
Jangbom Chai, Byung-Sung Kim, Wansoo Nah
PD-49Online Partial Discharge Detection in the Presence of Single and Multiple Defects in
Underground Power Cables
A.A. Khan* (Qualitrol Company LLC, UK), Y. Khan, N. Malik, A.A. Al-Arainy
PD-50A Study on the New Statistical Analysis of Maintain Window of Cable Using 3-parameter
Weibull Distribution
Na-rae Park* (Mok-Po National Maritime University, Republic of Korea), Young-hyun Kim, Jang-seob Lim
PD-51A Study on Aging Diagnosis of MV Cables Using 3-Dimensional Assessment of VLF Tanδ
Yong-hyun Kim* (Mok-Po National Maritime University, Republic of Korea), Dong-sub Kim, Sung-min
Kim, Na-rae Park, Woong Kim, Jang-seob Lim
PD-52 Transient Temperature Distribution of 10kV Power Cables in Trench Based on FEM
Analysis
Aixuan Zhao* (Xi'an Jiaotong University, China), Xu Lu, Junbo Deng, Guanjun Zhang, Jie Tian, Yan Lang,
Congwei Yao
PD-53
Ampacity Optimization for Cable Group Using PSO Algorithms
Aixuan Zhao* (Xi'an Jiaotong University, China), Xu Lu, Zhiliang Xu, Junbo Deng, Guanjun Zhang, Jie Tian,
Peng Yu
PD-54
SF6 Decomposition Characteristics under Floating Potential Defect
International Conference on Condition Monitoring and Diagnosis 2014 • 47
September 24, 2014
Lipeng Zhong* (Xi'an Jiaotong University, China), Shengchang Ji, Yanjie Cui, Jinyu Li, Yuanyuan Wang,
Jinlong Guo, Guolong Ji
13:30-14:50 SESSION PB : Transformer & Liquid Insulation
Lobby (2F)
Chair : Jeongtae Kim (Daejin University, Republic of Korea)
PB-01Effects of Various Transformer Oil Contaminations on Its Spectral Response
A. Abu-Siada* (Curtin University, Australia), Norazhar Abu Bakar, S. Islam, M. F. El-Naggar
PB-02Detection of Power Transformer Disk Space Variation and Core Deformation Using
Frequency Response Analysis
A. Abu-Siada* (Curtin University, Australia), N. Hashemnia, S. Islam
PB-03A Study on Effects of Voltage Harmonics on Distribution Transformer Losses
T. R. Blackburn* (University of New South Wales, Australia), Thinh Dao, B.T. Phung,
Eliathamby Ambikairajah
PB-04Analysis of the Ultrasound Emitted from Defective Insulators
L. H. Meyer* (University of Blumenau, Brazil), S. F. Stefenon, F. H. Molina
PB-05Experimental Investigation of Winding Temperature Rising Test Based on Distributed
Optical Fiber Sensing Technology in a Transformer
Yi Yin* (Shanghai Jiao Tong University, China), Hongliang Liu, Qian Zhang, Hui Fan, Zhiyong Chen,
Shuguo Gao, Wei Liu, Qiaohang Wang
September 24, 2014
PB-06
A Novel Transformer Fault Diagnosis Approach Based on Self-adaptive Search Glowworm
Swarm Optimization Algorithm
Huang Xinbo* (Xi’an Polytechnic University, China), Song Tong
PB-07Pattern Evolution of Disc-void Discharge inside Oil-paper Insulation with Different Aging
States
Yuan Li* (Xi'an Jiaotong University, China), Hai-Bao Mu, Ming-xiao Zhu, Yan-hui Wei, Xiao-yu You,
Guan-jun Zhang, Wei-zheng Zhang, Zhi-min Li
PB-08Maintenance Ranking Optimization of Oil-immersed Power Transformers Based on
Reliability Assessment
Min Lei* (Xi'an Jiaotong University, China), Xiao-Yu You, Fan Bai, Yao Chen, Ke Wang, Huan-Chao Cheng,
Jin-Zhong Li, Guan-Jun Zhang
PB-09Partial Discharge Characteristics at Oil/Polypropylene Film Interface with Different
Aging Condition
Ming-Xiao Zhu* (Xi'an Jiaotong University, China), Yuan Li, Hai-Bao Mu, Yan-Hui Wei, Xiao-Yu You,
Guan-Jun Zhang, Wei-zheng Zhang, Zhi-min Li
PB-10Partial Discharge and On-line Live Detection of Oil Immerse Power Equipment
Lipeng Zhong* (Xi'an Jiaotong University, China), Kui Ma, Bo Gao, Pei Ding, Xutao Wu, Rui Zhang,
Yanjie Cui
PB-11Partial Discharge and Dissolved Gases Characteristics of Gas-gap Defect Model under
AC-DC Combined Voltage
Xiaohan Zhang* (North China Electric Power University, China), Bo Qi, Chengrong Li, Zhen Wei, Jian Zuo
48 • CMD2014
PB-12Comparison of Ultra-high Frequency Sensors Performances for Transformer Partial
Discharge Detection
Guangzhen Wang* (China Electric Power Research Institute, China), Wenzhi Chang, Jiangang Bi,
Zijian Zhao, Wei Zhang, Yangchun Cheng
PB-13Temperature Characteristics of Interface Charge Accumulation on Oil Impregnated
Pressboard under Non-uniform DC Stress
Jian Zuo* (North China Electric Power University, China), Bo Qi, Chengrong Li, Yilong Chen, Xiaohan Zhang,
Chunjia Gao
PB-14Initiation Pyrolysis Simulation of Transformer Oil Based on ReaxFF Reactive Molecular
Dynamics
Xuelei Wang* (Shandong University, China), Qingmin Li, Rui Yang, Ying Zhang, Chengrong Li, Shuguo Gao,
Hui Fan
PB-15
The Impact of Plug-in Electric Vehicles on the Operating Life of the Distribution Transformer
Yunpeng Liu* (North China Electric Power University, China), Xing Liu, Zilai Qiu, Zhihua Zang, Yan Li,
Hongwei Zhou
PB-16The Effect of Temperature on the Breakdown Properties of Transformer Oil Based on ZnO
Nanoparticles
Fu Xin Wen* (Xi’an Jiaotong University, China), Ming Dong, Jin Miao, Lin Jia Liu
PB-17
Study on the Influence of UHVDC System Grounding Electrode Current on Power Transformer
Operation
Lu Yuncai* (Jiangsu Electric Power Research Institute, China), Li Wei, Wu Peng, Wei Chao
PB-18Research of the On-line Detecting Method of Iron-core and Copper Losses in Transformer
Haibao Mu* (Xi'an Jiaotong University, China), Sixiang Zhao, Kui Ma, Guanjun Zhang, Rui Zhang,
Xutao Wu, Bo Wu
Haibao Mu* (Xi'an Jiaotong University, China), Xiaoyu You, Yuan Li, Kui Ma, Guanjun Zhang, Rui Zhang,
Xutao Wu, Bo Wu
PB-20Study on Transformer Fault Diagnosis with a Comprehensive Diagnostic Model
Min Lei* (Xi’an Jiaotong University, China), Xiao-Yu You, Fan Bai, Feng-Jiao Wu, Yao Chen, Zhao Wang,
Guan-Jun Zhang
PB-21Impacts of the Frequency Effects on Partial Discharge Characteristics of the High
Frequency Power Transformer Insulation
Shuai Han* (North China Electric Power University, China), Qingmin Li, Xu lu, Xuwei Huang,
Gaoyong Wang, Xiaoguang Wei
PB-22Influence of Flow Velocity for Partial Discharge from Suspended Movable Bubble Defect
Jiabin Zhou* (State Grid Shandong Electric Power Company, China), Yufeng Chen, Wenbing Zhu,
Ju Tang, Xiaoxing Zhang
International Conference on Condition Monitoring and Diagnosis 2014 • 49
September 24, 2014
PB-19Study on Partial Discharge Properties of Oil-Impregnated Polypropylene Film Insulation
under Impulse Voltages
PB-23Simulation Analysis on FDS of Oil-paper Insulation System by FEM Approach
Yuan Liu* (Xi’an Jiaotong University, China), Ming Dong, Xue-zhou Wu, Ming Ren, Jin-Zhong Li, Rui Liu
PB-24The Rheological and Breakdown Properties of Transformer Oil and Oil-based Nanofluids
Ming Dong* (Xi’an Jiaotong University, China), Jin Miao, Fu-xin Wen, Christof Sumereder, Michael Muhr
PB-25The Propagation Characteristic of PD-generated EM Signals in Power Transformer
Windings with Different Size
Xu Zhao* (Xi’an Jiaotong Unversity, China), Yongpeng Meng, Yu Chen, Yonghong Cheng, Lin Zou,
Ruihai Li
PB-26Research on the Influence of Test Voltage on Oil-paper Insulation Frequency Domain
Spectroscopy
Xue-zhou Wu* (Xi'an Jiaotong University, China), Ming Dong, Guan-jun Zhang, Yuan Liu, Fan Bai,
Huan-Chao Cheng, Jin-zhong Li
PB-27
E xperimental Comparison of UHF Sensors Used for GIS PD Detection in Different Dimensions
Yang Xu* (Tsinghua University, China), Weidong Liu
PB-28Gas Generating Characteristic of the Needle Plate Electrode Oil-paper Insulation in the
Discharge Defect Development under the Action of AC-DC Composite Voltage
KwangHui An* (North China Electric Power University, China), Bo Qi, Chengrong Li, Miao Yu
PB-29Study on the Characteristics of Frequency Domain Spectroscopy of Vegetable Oil and
Vegetable Oil Impregnated Pape
Fan Lei* (Southwest Jiao Tong University, China), Guang-ning Wu, Bo Gao, Cheng-lin Li, Bing Wang
September 24, 2014
PB-30The Field Impulse Voltage Test for Transformer Based on Inductive Oscillating Switching
Impulse
Li Junhao* (Xi’an Jiaotong University, China), Hou Xinyu, Gao Yuan, Wu Xutao, Li Xiuguang, Guo Fei
PB-31Design of an Oil-filled GTEM Cell for the Characterization of UHF PD Sensors
M. Siegel* (University of Stuttgart, Germany), S. Tenbohlen
PB-32Degradation Effects and Diagnosis of On-load Tap Changer in Power Transformers
M. Wild* (University of Stuttgart, Germany), S. Tenbohlen, R. Jongen, E. Gulski
PB-33Experimental Investigation on Surface Discharge Phenomena of Oil/Paper Insulation
with Different Aging States
Rudiana Nurhadian* (Institut Teknologi Bandung, Indonesia), Yuan Li, Ming-Xiao Zhu, Yan-Hui Wei,
Yoga Napitupulu, Hai-Bao Mu, Jun-Bo Deng, Suwarno, Guan-Jun Zhang
PB-34Dielectric Response Measurement of Oil-Paper Insulation Characteristic due to Partial
Discharge
B. Setiawan* (Institut Teknologi Bandung, Indonesia), Ming Dong, M. Muhr, Suwarno
PB-35Electrical and Thermal Stress Effects to PD Measurement on Resin Insulated Voltage
Transformer
Ninil.U.A.Wardani* (PT.PLN(Persero), Indonesia), Thomas Betz, Suwarno
50 • CMD2014
PB-36A New Algorithm for Measuring Dissipation Factor and Capacitance of High Voltage
Condenser Bushing In-service for Condition Assessment
Asghar Akbari* (K.N. Toosi University of Technology, Iran), Hossein Chalangar
PB-37Comparison between Different De-noising Techniques for Acoustic Partial Discharge
Signals
Mohsen Bakhshi Ashtiani* (Iran University of Science and Technology, Iran), S. Mohammad Shahrtash,
Ayman H. El-Hag, Khaled Shaban
PB-38New Algorithm for Partial Discharge Location Using UHF Sensors in Power Transformer
Y.M. Kim* (Hyosung Coporation, Republic of Korea), K.R. Hwang, H.Y. Lee, J.R. Jung, H.J. Yang
PB-39Ultra-high Frequency (UHF) Partial-discharge Monitoring System for Power Transformers
Hyungjun Ju* (KEPCO Research Institute, Republic of Korea), Kison Han, Sungeun Goo, Jusik Kwak,
Younhho Ahn
PB-40An Experimental Investigation on the PPLP DC Breakdown Characteristics in LN2
S.D. Moon* (Hanyang University, Republic of Korea), W. Choi, I.J. Seo, Y.J. Lee, J.Y. Koo
PB-41
A Fault Diagnostic Expert System for Oil-immersed Power Transformer Using New Dissolved
Gas Analysis
H. D. Seo* (Hyosung Corporation, Republic of Korea), S. J. Kim, S. W. Kim, H. J. Yang
PB-42Analysis of Failure Statistics by Dissolved Gas Analysis of Power Transformer
Taehyun Jun* (KEPCO, Republic of Korea), Hyunjoo Park
PB-43Diagnostic Causes of Pole-mounted Transformer Using the Piezoelectric Element
Jae-Deuk Lee* (KEPCO, Republic of Korea), Yong-Woo Park, Byoun-Hun Jung, Chul-Bae Park,
Dong-Heon Lee, Jae-Hwan Pi, Han-Hong Kim
PB-45Experience of Oil Re-generation on a 132 kV Distribution Transformer
Z.D. Wang* (The University of Manchester, UK), N. Azis, Q. Liu, D. Jones, B. Wells, G.M. Wallwork
PB-46Economic Assessment on the Diagnosis of Aging Status of Oil-paper Insulation: Deviation
Degree of Aging Status
Kai Wu* (Xi’an Polytechnic University, China), Wen Kao, Wei Shen
PB-47Quantitative Characterization of Cu-sulfide Deposition and Its Influence on Insulation
Paper Aging
Jiangyan Yan* (State Key Lab of Alternate Electrical Power System with Renewable Energy Sources,
China), Qingmin Li, Yong Zhou, Zhaodong Wang, Chengrong Li, Hongsong Lian, Dongsheng Zheng
PB-48 Stochastic Probabilistic Model of Dielectric Response for Oil-paper Composite Insulation
Dongli Xin* (Southwest Jiaotong University, China), Bo Gao, Guangning Wu
International Conference on Condition Monitoring and Diagnosis 2014 • 51
September 24, 2014
PB-44The Study on the Phase-to-ground Voltage Variation During a Fault at 345kV Autotransformer's Tertiary (Ungrounded System)
Sei-Ill Oh* (KEPCO, Republic of Korea), Yong-Woo Park, Ki-Seob Yun, Myoung-Ho Kim, Chang-Gyuun Shin
PB-49
Study on the Vibration Characteristics of Power Transformers Based on a Wireless Vibration
Monitoring System
Yeye Zhu* (Xi'an Jiaotong University, China), Shengchang Ji, Hongkui Dong, Zhigang Cui
PB-50Gas Void Detection in Water Tank System Based on Time-Frequency Analysis
Yong-June Shin* (Yonsei University, Republic of Korea), Seung Jin Chang, Cuong Nguyen, Lingyu Yu,
Jin Bae Park
PB-51
Design of a Multi-functional Current Sensor for Condition Detection of Transformer Bushing
Yangchun Cheng* (North China Electric Power University, China), Tao Hu, Guangzhen Wang, Yuan Yang,
Ning Yang, Yuan Dai
PB-52A UHF PDM(Partial Discharge Monitoring) System for High Voltage Power Transformer
Ha-Young Lee* (Hyosung Corporation, Republic of Korea), Jae Ryong Jung, Young Min Kim, Hang Jun Yang
PB-53
Least Square Method-based Frequency Domain Dielectric Spectroscopy of Oil-paper
Insulation for Transformer
September 24, 2014
Bing Wang* (Southwest Jiaotong University, China), Guang-ning Wu, Fan Lei, Bo Gao
52 • CMD2014
Download