NHP Medium Voltage Switchgear

advertisement
NHP Medium Voltage Switchgear
Customised switchgear solutions built to last
MEDIUM VOLTAGE POWER
MV
MV
SOLUTIONS
NHP Electrical Engineering Products Pty Ltd
Sales 1300 NHP NHP
Sales 0800 NHP NHP
nhp.com.au
nhp-nz.com
easy to do business with
2
Why NHP?
We’re easy to do business with.
At NHP we’re solely committed to serving the needs of our customers in the
industrial electrical industry. From concept design through to installation and after
sales service, we are confident we have the experience and expertise to exceed
your expectations and ensure you get the best result for your project. How?
Well, put simply, we’re easy to do business with. Combining Partnerships, Agility,
Knowledge and Scalability, NHP offer the Australasian market quality, around-theclock service that forms the ultimate choice in our industry.
Partnerships:
Knowledge:
When you choose NHP you gain a valuable industry
partner. You gain access to an exclusive network of
quality global suppliers who together with NHP’s
50+ branch and regional locations across Australia
and New Zealand, can achieve an engineered
solution for your medium voltage application.
If your Medium Voltage application demands a
specialist team of trained project management,
design and engineering professionals, then NHP is
the ultimate choice. Bringing together over 40 years
of electrical industry experience, NHP’s dedicated
Medium Voltage project team promises to deliver
customiseable solutions from concept design
through to installation and project management.
Providing the perfect balance of knowledge and
experience, a partnership with NHP promises to last
the life of current and future projects, working together
with you to offer complete trust, assurance and peace
of mind.
We know that you have a range needs and that these
needs can change but calling on our vast industry
experience we know how to meet them. When it
comes to Medium Voltage, look no further than NHP.
If it’s Medium Voltage, partner with NHP.
Agility:
Scalability:
At NHP we understand your Medium Voltage
application needs and know that these needs can
often change throughout the life of a project. But with
a seamless combination of local and technical support
and a network of global suppliers, NHP have the agility
to provide real-time solutions that are backed by
around the clock service and support for not only the
life of a project but any future needs as well.
With all the scale of a large multi-national company,
NHP maintain a premium level of customer service
and attention to detail no matter how big or small
your Medium Voltage project.
Don’t be caught waiting. Choose NHP and get the
very best in Medium Voltage solutions – day in, day
out, right where you need them.
Be it our 1000+ expert staff, our 50+ branch and
regional locations, or our extensive network of global
suppliers, when you deal with NHP you will receive
all of this combined knowledge and expertise in an
‘easy to do business with’ solutions with a local focus!
TABLE OF CONTENTS
NHP Medium Voltage Switchgear Overview....................................................... 5
Application............................................................................................................................. 6
Air Insulated Switchgear (AIS) with visual earthing - DF-2.......................... 9
Ring Main Units (RMUs) - DR-6/DT-6......................................................................28
Withdrawable Switchgear - DW-2...........................................................................34
Gas Insulated Swithgear (GIS) - DI-2......................................................................44
Compact Air Insulated Switchgear - DF-3..........................................................50
4
NHP MEDIUM VOLTAGE SWITCHGEAR OVERVIEW
Suitable for 3.3kV, 6.6kV, 11kV, 22kV.
Air Insulated Switchgear (AIS) with visual earthing - DF-2
PAGE 9
AIS up to 24kV and 25kA 1 sec
DF-2’s modular air insulated switchgear design allows
you to create rational, economical and custom-made
combinations of medium-voltage cubicles with visible
earth contact.
Ring Main Units (RMUs) - DR-6/DT-6
PAGE 28
RMU up to 24kV and 25kA 1 sec
Compact and/or extensible gas insulated Ring Main Unit
with load break switch or integrated vacuum circuit
breaker.
Withdrawable Switchgear - DW-2
PAGE 34
AIS metalclad fully withdrawable up to
12kV and 31.5kA 4 sec
A family of air-insulated medium voltage switchgear
solutions for indoor installations.
Gas Insulated Switchgear (GIS) - DI-2
PAGE 44
GIS up to 36kV and 20kA 3 sec
A modular concept combining all medium voltage
functions. Suitable for 11kV, 22kV, 33kV.
Compact Air Insulated Switchgear - DF-3
PAGE 50
AIS compact up to 24kV and 20kA 1 sec
Our new modular and extendible switchgear.
5
Applications
Power stations generate electrical power, with voltages up
to 500,000V, which is transmitted to transformer stations
and dispersion stations. These substations distribute
medium voltage above 1kV to 36kV and it is here that
a number of NHP Medium Voltage Switchgear cubicles
can be used. A medium-voltage grid starts from every
substation and supplies a large area with medium-voltage.
Wherever medium-voltage enters residential areas,
industrial production companies, mining sites, data
centres, rail, hospitals and more, there is a medium voltage
cubicle fulfilling four essential functions.
1. POWER SUPPLY: the network distributor’s grid is
branched off to allow switching
2. SECURITY: the installation is secured with a load break
switch with HRC fuses, or by a load break switch with a
safety relay
3. MEASUREMENT: the energy consumption is measured
on the high-voltage, or low-voltage side
4. TRANSFORMATION: medium-voltage is transformed
into low-voltage (1,000V-400V-230V)
The Power Grid
CO-GENERATION MARKET GARDENING
CATERING INDUSTRY / SHOPPING CENTRE
PRODUCTION
DISPERSION
MEDIUM VOLTAGE
SWITCHGEAR
INFRASTRUCTURE
INDUSTRY
RESIDENTIAL AREAS
Commercial Buildings including
Hospitals and Data Centres
6
NHP Medium Voltage Switchgear OVERVIEW
DESIGN PHILOSOPHY AND APPLICATIONS
User-friendliness, safety and care for the environment
were the main motivators in the selection of NHP Medium
Voltage Switchgear. NHP can provide “made-to-measure”
solutions for all your medium-voltage needs.
NHP Medium Voltage Switchgear offers a wide range
of applications that can be used worldwide in many
industries. Cubicles can be used with distribution and
dispersion switchgear, electrical sub-stations and
medium-voltage engines, wind generators, cogeneration,
and much more.
The NHP Medium Voltage Switchgear range provides a
solution for all your needs and demands as it can replace
obsolete installations, extend existing installations, and it is
also perfectly suited for brand new installations.
The NHP Medium Voltage Switchgear cubicles are a
modular concept based on the “building blocks” principle,
which means that cubicles are produced in series. As a
result these products meet the highest technical standards
in a rational and economically sound way. The combination
of cubicles is unlimited. Very complex diagrams of
distribution and transformer switchgear can be compiled
through this extensive spectrum of possibilities.
Cubicles contain standard functional interlocks which
allows for effortless application and installation in most
consumer work spaces. As a result, capacity loss will be
minimal. Additionally, the cubicles have been fitted with
a system for pressure release which shields the user from
the consequences of an internal arc.
7
INTERNAL ARC MITIGATION
OPTION WITH BUILT-IN ARC-KILLER
A short-circuit or another malfunction can create an
internal arc. An internal arc in a Medium Voltage cubicle
could severely damage the installation and possibly injure
the operator.
Protect your cubicles, infrastructure and your staff against
the consequences of an internal arc. The built-in Arc-Killer
extinguishes an arc in less than 50ms.
NHP Medium Voltage Switchgear cubicles are designed to
mitigate the creation of internal arcs and therefore protect
both the operator and the installation. Through a strategic
pressure release system, the internal arc is restricted to
the compartment where it originated and it does not
spread towards the operator or to other compartments.
The cubicles are specifically designed to minimize the
consequences of an internal arc. All provided cubicles are
fitted on the rear side with overpressure valves pointing
downward as a standard.
NHP Medium Voltage Switchgear cubicles have been
tested with these specifications at independent, and
accredited testing solutions (for example: IPH, Kema).
The load break switches have been tested according to
IEC standards and consequently, all NHP Medium Voltage
cubicles are internal arc resistant.
Without Arc-Killer
The NHP Medium Voltage Switchgear range includes the
Arc-Killer SV-25 and SV-53, a system for detecting and
extinguishing an internal arc. The Arc-Killer extinguishes
the arc by directing it to a metal earthed short circuit. The
arc is extinguished in less than 50ms.
Our modules are metal enclosed cubicles combined
with a shaft at the rear end. The shaft absorbs any gasses
(in case of an internal arc) that escape through the
overpressure valves. As a result, the expansion of hot
gasses in a room can be reduced to an absolute minimum.
NHP Medium Voltage Switchgear cubicles offer protection
against an internal arc classification IAC category B, FLR 20
kA 1 s. (F=frontal, L=lateral, R=rear).
As a result, the operator is protected against the
consequences of an arc whether they stand in front of the
switchboard, next to it or behind it.
With Arc-Killer
The patented SV-25 and SV-53 Arc-Killer takes safety to a new level. Not just the operator and the environment are
shielded from harm, but the super-swift arc extinguishing system allows cubicles to be back in operation very quickly
in case of an internal fault.
What’s more, the Arc-Killer’s improved security features place less strict demands on the installation room.
As such, the Arc-Killer couples security and operational safety with flexible room demands.
8
DF-2
AIR INSULATED SWITCHGEAR (AIS) WITH VISUAL EARTHING
DF-2
A MODULAR CONCEPT COMBINING ALL MEDIUMVOLTAGE FUNCTIONS.
DF-2’s modular design allows you to create rational,
economical and custom-made combinations of mediumvoltage cubicles with a rated voltage of up to 24kV.
9
DF-2
COMPARTMENTS
SWITCHGEAR COMPARTMENT
In this compartment, the gas filled (RV44) load break switch is
double sealed, which acts as the physical separation between
the busbar set and the cable compartment. The switch has
two functions: it connects or interrupts the electrical current
between the high voltage cables and the busbar.
BUSBAR COMPARTMENT
The busbar compartment is located in the upper part of
the cubicle and behind the low-voltage compartment. The
modular busbar set is manufactured from specially provided
electrolyte F25 copper of 60 x 10mm with n = 5mm (800A).
Standard as well as 1250A option is available.
Several cubicles are connected through the bar set
compartments. Hexagonal bolts connect the busbars to the
upper contact surfaces of the RV44 load break switch.
CABLE COMPARTMENT
The cable compartment is located behind the interlocked,
removable door of the DF-2 cubicle. This part of the field
receives the cable(s) and contains the necessary equipment
to connect the cable(s). The earthing switch is installed below
the load break switch on the right side, ensuring a “visible
earthing” when the earthing switch is closed. In a DF-A cubicle,
the cables are connected to the contact points below the
RV 44 load break switch. The cables of the DF-P cubicles are
connected to the lower fuse base side. This type of cubicle
also has an additional auxiliary earthing switch to divert any
residual current. DF-D type cubicle have the earthing switches
located in the cable compartment below. The removable
door, the sectional floor panels which house the necessary
conductive rubber for the cables, and the cable supports all
simplify the cable connection.
LOW-VOLTAGE COMPARTMENT
CABLE COMPARTMENT
BUSBAR COMPARTMENT
SWITCHGEAR COMPARTMENT
LOW-VOLTAGE COMPARTMENT
The drive mechanism that controls the RV44 load break switch
and the earthing switch EM20 is fitted with the synoptic
diagram and is located behind the front panel. Several
accessories, such as the auxiliary contacts, switch-on or
switch-off coils, and minimum voltage relays are also located
in this compartment. Any control with the necessary electrical
switchgear, a control and clamp strip are also installed in
this compartment. The compartment is easily accessible by
removing the front panel.
9
10
DF-2
DF-2 MODULE RANGE
TECHNICAL SPECIFICATIONS OF MODULES
Rated Voltage
kV
12
12*
24
- To earth and between phases
kV
75
95
125
- Over the insulated distance
kV
85
110
145
kV
28
38
50
Impulse withstand voltage 1.2 / 50 μs
Power frequency withstand voltage:
- To earth and between phases
kV
32
45
60
Rated frequency
- Over the insulated distance
Hz
50/60
50/60
50/60
Rated current
A
800/1250**
800/1250**
630
Rated short-time current 1s.
kA
25
25
20
Rated peak value of the current
kA
63
63
50
- Mainly active load
A
800/1250**
800/1250**
630
- Closed loop
A
800
800
630
- Load cable charging
A
18
18
18
- Making current
kÂ
63
63
50
- Earth fault
A
100
100
100
- Earth fault cable charging
A
30
30
30
kA
16
16
16
Breaking capacity RV44 (Class E3)
Internal arc 1s.
Degree of protection
IP4X
Mechanical durability c/o
1000
Standards
IEC 62271-100, IEC 62271-1, 62271-102,
-103, -105, 62271-200
and IEC 61243-5
Certificates
KEMA/IPH
Notes:
* Utilities Specifications
** According to IEC 62271-103, Class E1
11
DF-2
MODULE SPECIFICATIONS AND DIMENSIONS
12
Load break switch with interlocked
earth switch - DF-A/DF-A+
PAGE 13
Protection cubicle with vacuum circuit
breaker - DF-AAD/ DF-AAD+
PAGE 20
Load break switchfuse with interlocked
earth switch - DF-P
PAGE 14
Protection cubicle with double
interruption - DF-AADT
PAGE 21
Auxiliary voltage cubicle with interlocked
earthing switch - df-av
PAGE 15
Busbar coupling cubicle - DF-LK
PAGE 22
Vacuum circuit breaker with integrated
protection relay - DF-D/DF-D+
PAGE 16
Transformer housing - DF-T
PAGE 23
Protection cubicle with vacuum circuit
breaker - DF-D/EDN/ DF-D+/EDN
PAGE 17
Metering cubicle DF-C-750/DF-C-500
PAGE 25
Protection cubicle with remountable
vacuum circuit breaker with integrated
protection relay - DF-D-500
PAGE 18
Busbar link panel - DF-LKB
PAGE 26
Protection cubicle with vacuum
circuit breaker (magnetic driven) and
integrated protection relay.
PAGE 19
Cable connection panel or bus riser - DF-K
PAGE 27
DF-2
LOAD BREAK SWITCH WITH INTERLOCKED EARTH SWITCH
DF-A
DF-A+ (with arc killer)
Application:
Incomer or feeder-load break switch with interlocked earthing switch.
Standard Equipment
• Three phase load break switch RV44, class E3 according to IEC 62271-103, gas insulated
• Cable support
• Door interlock 940
• Sockets for capacitive voltage detector with parallel testing possibility
• Low-voltage compartment
Options
• Auxiliary contacts on load break switch and or earthing switch
• Key interlock on load break switch and/or earthing switch
• Motor operation local or remote control: 24-48-110V-AC/DC or 220VAC
• Short-circuit indicator
10
• Voltage indicators
• Plinth 200mm to 400mm height
Ø79
• Gland plate AL/BRASS
I
I
0
1700
0
180
775
570
365
205
150
24
Rated current
A
800-1250
630
Short-term current
kA
25
20
s
1
1
55
60
400
100
**
500
900mm
1050
1700
1700
Height between
ground and end
socket
mm
945
835
Height between
ground and cable
support
mm
445
445
Weight
kg
180
180
Weight with Arc Killer
kg
240
240
210
210
500
DF-A
10
Ø79
400
100
900
1050
55
60
900
995
775
570
500
1050
205
mm
mm
150
Width
Depth
365
1090
995
12 *
860
1700
L3
900
kV
Height
HR
DEBA
L2
*
Rated Voltage
duration of current
HR
DEBA
L1
500
Specifications & Dimensions
Time of the short
HR
DEBA
210
500
DF-A+ (Arc Killer Option)
Notes:
* Arc Killer Option
13
DF-2
load break switchFUSE with interlocked earth switch
DF-P
Application:
Transformer protection and Medium Voltage
970 equipment protection.
*
60
900
400
100
210
500
995
Options
• Set of auxiliary contacts on load break switch and/or earthing switch
• Key interlock on load break switch and/or earthing switch
• Shunt trip **
• Under voltage release **
• Closing release **
• Motor operation **
• Contact “fuse blown”
• Automatic recloser
• Set of 2 or 3 voltage transformers
• Voltage indicators
• Plinth: 200mm - 400mm
Specifications & Dimensions
Rated Voltage
kV
12
24
Rated current
A
800-1250
630
Short-term current
kA
25
20
Time of the short
duration of current
s
1
1
Width
mm
500
500
Depth
mm
1050
1050
Height
mm
1700
1700
Height between
ground and end
socket
mm
460
415
Fuse size
mm
292 (DIN)
442
(DIN)/
UTE
kg
210
210
Weight
14
205
570
995
**
775
Ø79
365
10
150
9 10
9 10 1
1700
1700
30 31 1 2
3
2829
2 3
2 3 4
500
12 1
9 7
7 8 9 10
11
5 6
210
11
210
4
A
7 8
0
24
212223 25 26 27
0
0
Standard Equipment
• Three-phase load break switch RV44, class E3
according to IEC 62271-105, gas insulation
• Double earthing switch with mutual interlock
• Socket for HRC fuses:
- 292mm DIN 10 at 17.5kV
- 442mm DIN 20 at 24kV
- UTE
• Three-pole fuse trip
• Door interlock
• Sockets for capacitive voltage detector
500
900
• Low-voltage
compartment
8
I
I
20
L3
5 6 7
HR
DEBA
L2
4 5 6
HR
DEBA
L1
15 1617 18
13 14
19
12
HR
DEBA
DF-2
AUXILIARY VOLTAGE CUBICLE with INTERLOCKED EARTHING SWITCH
DF-AV
Application:
For supply of auxiliary voltage with cubicle interlocked earthing switch.
Standard Equipment
• Three-phase load break switch RV44, class E3 according to IEC 62271-103, gas insulation
• Double interlocked earthing switch
• HRC fuse-holders:
- 292 mm DIN 10 at 17.5 kV
- 442 mm DIN 20 at 24 kV
- UTE
970
• Door interlock
• Sockets for capacitive voltage detector
• Low-voltage compartment
• Assembly plate for auxiliary transformer(s)
HR
HR
HR
DEBA
DEBA
DEBA
L1
L2
L3
I
I
0
1700
0
210
Options
• Set of auxiliary contacts on load break switch and/or earthing switch
• Key interlock on load break switch and/or earthing switch
• Motor operation *
• Contact “fuse blown”
• Set of 1, 2 or 3 voltage transformers
• Voltage indicator(s)
• Plinth: 200mm - 400mm
• VT: xx kV/x V x VA CL.XX
60
Specifications & Dimensions
Rated Voltage
kV
12
24
Rated current
A
800-1250
630
Short-term current
kA
Time of the short
duration of current
25 900
20
s
1
1
Width
mm
500
500
Depth
mm
1050
1050
Height
mm
1700
1700
Height between
ground and end
socket
mm
460
415
Fuse size
mm
292 (DIN)
442
(DIN)/
UTE
kg
210
210
Weight
400
100
55
900
995
**
1700
150
10
205
500
500
15
DF-2
vacuum circuit breaker with integrated protection relay
DF-D
DF-D+ (with arc killer)
Application:
Protection of descending feeders with circuit breaker, transformer and Medium Voltage
980
equipment protection.
205
940
1050
110
750
490
DF-D
900
1050
365
570
775
750
Cubicle Options
• Set of auxiliary contacts on the load break switch and/or earthing switch
• Key interlock on load break switch and/or earthing switch
• Motor operation on load break switch: 24-48-110VAC/DC and 220VAC
• Short-circuit indicator
• Earthing connection above circuit breaker
• Circuit breaker gas insulated
• Voltage indicators
• Plinth: 200mm - 400mm
Options on the circuit breaker
• Motor operation **
• Closing release
• Shunt trip **
• Under voltage release **
• Set of auxiliary contacts
• Error contact
• Supply for test protective relay (battery block)
• Cycle counter
• Automatic recloser
• Key interlock
Specifications & Dimensions
DF-D+ (Arc Killer Option)
16
940
1050
995
940
1155
750
55
60
*
O
460
150
1700
1700
I
I
O
110
9 10 1
2 3
2 3 4
9 10
30 31 1 2
3
2829
7 8
12 1
9 7
7 8 9 10
11
5 6
11
4
A
24
212223 25 26 27
460
Standard Equipment
• Three-phase load break switch RV44, class E3 according to IEC 62271-103, gas insulation
• Vacuum circuit breaker with integrated protection relay, current transformers and release
10
• Interlocked earthing switch with rated making capacity up to 63kA downstream of the
Ø79
capacity switch
• Cable support
• Door interlock
• Sockets for capacitive voltage detector
460
• Voltage indicators
100
• LV compartment
8
I
0
20
L3
5 6 7
HR
DEBA
L2
4 5 6
HR
DEBA
L1
15 1617 18
13 14
19
12
HR
DEBA
I
0
Rated Voltage
kV
12
24
Rated current
A
800/1250
630
Short-term current
kA
25
20
Time of the short
duration of current
s
1
1
Width
mm
750
750
Depth
mm
1050
1050
Height
mm
1700
1700
Height between
ground and socket
mm
445
445
Weight
kg
460
460
Weight with Arc Killer
kg
490
490
DF-2
Protection cubicle with vacuum circuit breaker
DF-D/EDN
DF-D+/EDN (with arc killer)
Application
Protection of descending feeders with circuit breaker, transformer and Medium Voltage
equipment protection.
A
I
1700
0
I
O
460
150
205
365
570
900
1050
995
460
55
60
775
Ø79
100
570
365
205
10
12
24
Rated current
A
800/1250
630
s
25
20
9001
1
1265
900
1050
460
55
kV
kA
DF-D/EDN
Ø79
995
Rated Voltage
Time of the short
duration of current
150
750
Specifications & Dimensions
Short-term current
490
775
7 8
15 1617 18
13 14
19
12
1700
Options on the circuit breaker
• Motor operation **
940
• Closing release
1155
• Shunt trip **
• Under voltage release **
• Set of auxiliary contacts
• Switch counter
• Automatic recloser
• Button press control on circuit breaker
• Remote control on circuit breaker
• Key interlock
60
4 5 6
20
2 3
7 8 9 10
11
5 6
9 10 1
L1 L2 L3
I
0
750
Cubicle Options
• Protection relay (to be specified by the customer)
10
• Current transformer (to be specified by the customer)
• Set of auxiliary contacts on the load break switch and/or earthing switch
• Key interlock on load break switch and/or earthing switch
• Motor operation on load break switch: 24-48-110VAC/DC and 220VAC
• Short-circuit indicator (to be specified by the customer)
• Earthing connections upwards from the circuit breaker
• Circuit breaker gas insulated
1228
• Plinth: 200 - 400mm
1700
30 31 1 2
3
2829
4
24
212223 25 26 27
Standard Equipment
• Three-phase load break switch RV44, class E3 according to IEC 62271-103, gas insulation
• Vacuum circuit breaker
• Interlocked earthing switch with rated making capacity up to 63kA downstream of the
capacity switch
• Cable support
1120
• Door interlock
• Sockets for capacitive voltage detector
• Voltage indicators
• LV compartment
100
750
Width
mm
750
750
Depth
mm
1050
1050
Height
mm
1700
1700
Height between
ground and socket
mm
445
445
Weight
kg
460
460
Weight with Arc Killer
kg
490
490
DF-D+/EDN
(Arc Killer Option)
17
DF-2
Protection cubicle with remountable vacuum circuit breaker
970
with integrated protection
relay
I
400
DF-D-500
0
I
30 31 1 2
3
2829
7 8
212223
9 10 1
2 3
2 3 4
2425 26
27
12 1
9 7
995
940
1050
55
500
357
60
O
400
602
205
I
O
Ø79
Standard Equipment
• Three-phase load break switch RV44, class E3 according to IEC 62271-103, gas insulation
• Vacuum circuit breaker with integrated protection relay, current transformers and release
• Interlocked earthing switch with rated making capacity up to 63kA downstream of the
375
100
capacity switch
500
• Cable support
940
500
1155
• Door interlock
• Sockets for capacitive voltage detector
• Low voltage compartment
• Draw-out circuit breaker
847
I
1700
1700
110
7 8 9 10
11
5 6
11
4
A
9 10
Application
10
Feature breaker allowing fast exchange of the circuit breaker (minimum
downtime).
8
0
20
L3
5 6 7
HR
DEBA
L2
4 5 6
HR
DEBA
L1
15 1617 18
13 14
19
12
HR
DEBA
Cubicle Options
• Set of auxiliary contacts on the load break switch and/or earthing switch
• Key interlock on load break switch and/or earthing switch
• Motor operation on load break switch: 24-48-110VAC/DC and 220VAC
• Short-circuit indicator (to be specified by the customer)
• Voltage indicators
• Plinth: 200 - 400mm
Options on the circuit breaker
• Motor operation **
• Closing release
• Shunt trip **
• Under voltage release **
• Set of auxiliary contacts
• Error contact
• Supply for test protective relay (battery block)
• Switch counter
• Automatic recloser
• Button press control on circuit breaker
• Remote control on circuit breaker
• Key interlock
Specifications & Dimensions
Rated Voltage
kV
12
Rated current
A
630
Short-term current
kA
25
Time of the short
duration of current
s
1
mm
500
Width
Depth
mm
1050
Height
mm
1700
Height between
ground and socket
mm
450
kg
400
Weight
18
DF-2
Protection cubicle WITH vacuum circuit breaker
(magnetic driven) AND integrated protection relay
DF-DT
Standard Equipment
• Three-phase load break switch RV44 - class E3
according to IEC 62271-103, gas insulation
• Vacuum circuit breaker with magnetic drive and 6NO / NC auxiliary contacts
• Interlocked earthing switch with a rated making
capacity up to 63kA downstream of the circuit breaker
• Cable support structure
• Door interlock
• Sockets for capacitive voltage detectors
Ø10
• Voltage presence indicators
• LV compartment
360
1700
Application
Protection of feeders with circuit breaker, voltage and current transformer and Medium Voltage
protection (max 1250A).
570
750
60
1050
775
Cubicle Options
• Current transformer (to be specified by the customer)
• Voltage transformer (to be specified by the customer)
• Set of auxiliary contacts on the load break switch and/or earthing switch
• Key interlock on load break switch and/or earthing switch
• Choice of auxiliary voltage 24-48-110VDC or 110-220VAC
• Short circuit indicator (to be specified by the customer)
• Earthing connection upstream from the circuit breaker
100
• Voltage indication
• Plinth: 200mm - 400mm
750
940
Options on the circuit breaker
• Under-voltage release (electronic)
• Supplementary auxiliary contacts
• Operation counter
• Reclosing function (standard)
• Remote control
• Interlock
Specifications & Dimensions
Rated Voltage
kV
12
24
Rated current
A
800-1250
630-1250
Short-term current
kA
16/20/25
16/20
Time of the short
duration of current
s
1/02/03
1/02/03
Width
mm
750
750
Depth
mm
940
940
Height
mm
1700
1700
Height between
ground and socket
mm
450
450
kg
360
360
Weight
19
DF-2
Protection cubicle with vacuum circuit breaker
DF-AAD
Standard Equipment
• Three-phase load break switch RV44, class E3 according toØ10IEC 62271-103, gas insulation
• Vacuum circuit breaker with/without integrated protection relay
• Door interlock
• Low voltage compartment
• Holder for capacitive voltage indicators load break switch 1 and/or 2
12 1
30 31 1 2
3
2829
9 10 1
2 3
2 3 4
9 7
O
100
Cubicle Options
• Set of auxiliary contacts on load break
switch
1
and/or
2
940
750
1155
• Key 750
interlock on load break switch 1 and/or
2, and/or earthing switch
• Mechanical interlock between the load break switches
• Motor operation on load break switch 1 and/or 2: 24-48-110VAC/DC and 220VAC
• Earthing-switch
• Earthing connections on load break switch 1 and/or 2
• Earthing connections outside of cubicle
• Capacitive voltage indicators load break switch 1 and/or 2
• Plinth: 200mm - 400mm
• Current transformers
60
940
1050
110
750
540
150
DF-AAD
Options on the circuit breaker
• Motor operation/closing release/shunt trip **
• Current transformer shunt trip
• Delay/direct under voltage release **
• Set of auxiliary contacts
• Error contact
• Supply for test protective relay (battery block)
• Switch counter
• Automatic recloser
• Button press control on circuit breaker
• Remote control on circuit breaker
• Key interlock
900
1050
Specifications & Dimensions
DF-AAD+
(Arc Killer Option)
20
110
I
995
510
I
O
1700
1700
205
7 8 9 10
11
5 6
11
4
A
940
1050
I
0
9 10
I
0
7 8
L3
24
212223 25 26 27
HR
DEBA
L2
8
HR
DEBA
L1
20
HR
DEBA
L3
5 6 7
HR
DEBA
L2
4 5 6
HR
DEBA
L1
Application
1010
Protection of descending feeders with transformer and Medium Voltage equipment provided
with circuit breaker and double Separation of busbar upstream and downstream.
510
15 1617 18
13 14
19
12
HR
DEBA
DF-AAD+ (with arc killer)
Rated Voltage
kV
12
24
Rated current
A
800-1250
630
Short-term current
kA
25
20
Time of the short
duration of current
s
1
1
Width
mm
750
750
Depth
mm
1050
1050
Height
mm
1700
1700
Weight
kg
510
510
Weight
kg
510
510
DF-2
Protection cubicle with double interruption
Standard Equipment
• Double, three-phase load break switch RV44 - class E3 according to IEC 62271-103,
gas insulation
• Vacuum circuit breaker with magnetic drive and 6NO / NC auxiliary contacts
• Cable support structure
• Door interlock
• Sockets for capacitive voltage detectors
• Voltage presence indicators
• LV compartment
150
750
940
Specifications
& Dimensions
Rated Voltage
940
1050
995
100
60
Options on the circuit breaker
• Under-voltage release (electronic)
• Supplementary auxiliary contacts
• Operation counter
• Reclosing function (standard)
• Remote control
• Interlock
360
750
205
Cubicle Options
• Auxiliary contacts on load break switch 1 and/or 2 up to 3NO/NC
• Auxiliary contacts on the earthing switch up to 2NO/NC
• Key interlock on the load break switch and/or earthing switch
• Choice of auxiliary voltage 24-60-110VDC or 110-220VAC
Ø10
• Short circuit indicator (to be specified by the customer)
• Current transformers (to be specified by the customer)
• Earthing connection upstream from the circuit breaker
• Voltage indication
• Plinth: 200mm - 400mm
1700
DF-AADT
kV
12
24
Rated current
A
800-1250
630-1250
Short-term current
kA
16/20/25
16/20
Time of the short
duration of current
s
1/02/03
1/02/03
Width
mm
750
750
Depth
mm
940
940
Height
mm
1700
1700
Weight
kg
360
360
21
DF-2
Busbar coupling cubicle
DF-LK
940
Application
Coupling between two parts of the Medium Voltage panel.
150
995
1700
Specifications & Dimensions
60
150
Options
• Holder for capacitive voltage indicators load break switch 1 and/or 2
100
• Set of auxiliary contacts on load break switch 1 and/or 2
• Key interlock on load break switch 1 and/or 2, and/or earthing switch
750
750
900
• Mechanical interlock between the load
break switches
• Motor operation on load break switch 1 and/or 2: 24-48-110VAC/DC and 220VAC
• Earthing-switch
• Earthing connections on load break switch 1 and/or 2
• Earthing connections outside of cubicle
• Capacitive voltage indicators load break switch 1 and/or 2
• Plinth: 200mm - 400mm
• Current transformers
900
1050
900
1050
Ø10
205
27
2425 26
9 10
9 10 1
7 8
212223
8
30 31 1 2
3
2829
20
5 6 7
9 10
7 8
15 1617 18
13 14
19
12
8
4 5 6
20
12 1
9 7
2 3
1700
11
2 3 4
A
7 8 9 10
11
5 6
2 3
2 3 4
9 10 1
5 6 7
30 31 1 2
3
2829
245
4
12 1
9 7
7 8 9 10
11
5 6
245
11
4
A
24
212223 25 26 27
Standard Equipment
• 2 three-phase load break switch RV 44, class E3
according to IEC 62271-103, gas insulation
• Door interlock
• Low-voltage compartment
4 5 6
I
0
15 1617 18
13 14
19
12
I
0
750
22
Rated Voltage
kV
12
24
Rated current
A
800-1250
630
Short-term current
kA
25
20
Time of the short
duration of current
s
1
1
Width
mm
750
750
Depth
mm
1050
1050
Height
mm
1700
1700
Weight
kg
245
245
DF-2
Transformer housing
DF-T
Application
The DF-T cubicle has been designed from the long-term practical experience of installing and
connecting distribution transformers.
B
B
B
A
Cubicle Options
• Key interlock with LV protection
• Shaft with rail set on top of the transformer housing
• LV compartment
• Oil receptacle
• Forced ventilation
• With closed back
• With closed roof
• Extra ventilation
• Opening for LV switch of LV equipment
• Opening for the thermometer
• Opening for digital measuring set
• Holder for capacitive voltage indicators
• Capacitive voltage indicators
B
• IP2X / IP4X
/ IP315
• Interlockable doors
• Interlock possibilities
*
C
Standard Equipment
• Windows
• Ventilation openings
• Hinge door(s) in function of the cubicle width
A
If a built-in LV switch is required in the DF-T, the size needs to be specified. The DF-T was
designed specifically with ventilation problems in mind. The ventilation openings in the cubicle
ensure that the transformer will constantly be ventilated. The specific concept allows the
transformer to be driven in and out smoothly at all times.
C
C
Width
Height
Depth
100-160 kVA
1200
1900
1050
250-630 kVA
1400
2100
1150
800-1000 kVA
1800
2100
1150
1250-1600 kVA
2000
2100
1400
2000-2500 kVA
2400
2400
1500
B
A
A
Dimensions Oil Filled Transformers
Dimensions Cast Resin Transformers
Width
Height
Depth
1500
1900
1050
1800
2100
1150
2000
2100
1200
1250-1600 kVA
2200
2200
1300
2000-2500 kVA
2400
2400
1400
100-160 kVA
250-630 kVA
800-1000 kVA
B
C
23
DF-2
DF-C-750 | Metering cubicle
DF-P | Protection cubicle
DF-A | Load break switch
with interlock earth switch
(outgoing)
DF-A | Load break switch
with interlock earth switch
(incoming)
Transformer
29
24
DF-2
Metering cubicle
DF-C-500
DF-C-750
Standard Equipment
• 3 Ti’s xA => 5A
• 3 Tp’s xV => 110V, V3
Cubicle Options
• Additional current transformers
• Additional voltage transformer with or without Medium Voltage and LV protection
• Support for the positioning of measuring transformers
• Measuring system with 3 CTs and 3 VTs
• Measuring system with KWH metering and Kvarh
metering (requirements to be specified by the customer)
• Current measurement system
• Voltage measurement system
• Plinth: 200mm - 400mm
• Low voltage compartment safety box to secure voltage circuits
240
1700
p
330
750
p
720
The following
voltage transformer VT specifications need to be specified by the customer:
940
• Primary voltage, secondary voltage, capacity and precision class, 205
insulation class
A
720
760
Time of the short
up to
1250
kA
25
20
s
1
1
Width
mm
500
500
Depth
mm
720
720
Height
mm
1700
1700
kg
240
240
up to
630
100
300
500
duration of current
570
365
205
10
Ø79
Ø79
900
995
190
55
60
280
100
900
DF-C-500
775
Weight **
55
1050
Rated current
195
24
150
12
79
kV
55
Rated Voltage
165
Specifications & Dimensions
Short-term current
165
The following current transformer CT specifications need to be specified by the customer:
• Primary current, secondary current, capacity and precision class, insulation class, rated
10
short time current
100
750
DF-C-750
25
DF-2
Busbar link panel
DF-LKB
Application
Panel above switchgear, required for connection of two non-adjacent panels. Available for
connecting panels of different dimensions.
Standard Equipment
• 1 three-phase load break switch RV 44, class E3
according to IEC 62271-103, gas insulation
• Low-voltage compartment
• Holder for capacitive voltage indicators load break switch left/right
• In case of coupling between two cubicles of 750mm,
a final piece of 250mm will be provided
Cubicle Options
• Set of auxiliary contacts on the load break switch
• Key interlock on load break switch
• Motor operation on load break switch: 24-48-110VAC/DC and 220VAC
• Earthing ball clamps on load break switch left/right
• Earthing ball clamps outside of cubicle
• Capacitive voltage indicators on load break switch left/right
• Plinth: 200-400mm
Specifications & Dimensions
26
Rated Voltage
kV
12
24
Rated current
A
800-1250
630
Short-term current
kA
25
20
Time of the short
duration of current
s
1
1
Width
mm
1000/1250
1000/1250
Depth
mm
975
975
Height
mm
500
500
Weight
kg
162
176
DF-2
Cable connection panel or bus riser
DF-K
Application
Cubical for a separate cable connection zone. These panels can also be used as busbar zones or
busbar risers.
1700
Options
• Holder for capacitive voltage indicators
• Capacitive voltage indicators
• Short-circuit detectors (to be specified by the customer when ordering)
940
• Earthing switch
• Set of auxiliary contacts on earthing switch
• Key interlock on earthing switch
• Earthing ball clamps
• Current transformers in the busbar
• Voltage transformers with of without protection in the busbar
• Plinth: 200mm - 400mm
• Door interlock
55
775
990
Rated Voltage
kV
12
24
Rated current
A
up to 1200
up to 630
Short-term current
kA
up to 25
up to 20
Time of the short
duration of current
s
1
1
900
400
100
60
Specifications & Dimensions
210
500
Width
mm
M
M
Depth
mm
1050
1050
Height
mm
M
M
kg
55
55
Weight **
570
Ø79
365
Possible Connections
• Bottom in - top out
• Bottom in - top left out
• Bottom in - top right out
900
1700
150
Ø10
210
500
27
DR-6/DT-6
RING MAIN UNITS (RMUs)
DR-6/DT-6
A compact and extensible gas insulated ring main unit with
load break switch or integrated vacuum circuit breaker.
Safe, reliable, compact and insensible to the environment in the
field of electricity distribution up to 24kv.
28
DR-6/DT-6
DESCRIPTIONS
DR-6/DT-6
LBS operating axle
Position indicator
Release rotary button
Earthing switch operating axel
Synoptic diagram
Voltage indicator
Cable compartment
Acces door
Circuit breaker tripping axle
Operation button circuit breaker
Pressure indicator
Protection relay
LBS operating axle
Position indicator
Earthing switch operating axle
Voltage indicators (VDS)
Access door to cable compartment
29
DR-6/DT-6
DEVELOPMENT & MANUFACTURING PHILOSOPHY
The DR-6/DT-6 range offers a compact, safe, reliable and economical design which is free of any possible environmental
aggression. Extensions on site is possible without any special tooling nor particular surrounding conditions.
THE COMPONENTS
Load break switch
The three position load break switch (ON/OFF/Earth) is in accordance with the IEC
requirements. The concept insures a natural interlock of the primary functions of the cubicle.
The arc extinction is insured by gas, which reduces arcing time. The load break switch RV44 of
the DF-2 range is of the class E3/M1 (100 CO and 1000 mechanical operations) following IEC
62271-103 and is therefore a perfect application.
Circuit breaker
The SGC ISM-086 vacuum circuit breaker (VCB) of the magnetic actuator type uses the
latest vacuum interrupter technology. The VCB can only be closed electrically and therefore
mechanical closing is not possible*. The VCB can be opened only electrically. The circuit breaker
operates through a control module and a self powered digital protection relay RP600, this
together with the three CT’s allows the detection of over-current and earth faults failures.
(*) In absence of auxiliary voltage, a hand operated generator can be used.
The fuse holders
The fuse holders are made for HRC fuses of the DIN and UTE type for voltages of 12, 12 (Utilities
Specification) and 24kV. A simple intelligent artifice allows the change without any particular
tooling. Fuse holders are made from epoxy with a non-losable cover, and a fuse supporting
structure firmly fixed to the cover. Earthing on both sides of the fuses is clearly marked on
the synoptic diagram. The fuse holder is water tight and tested in accordance with the IEC
standards. Access to the fuse holders is facilitated by a simple and logic interlock system
allowing the opening of the door only after earthing of the cubicle.
The mechanical drives
Deba Components mechanical drives have already been subject to intensive tests and usage
in the DF-2 range of products. The same design has been implemented in the DR-6/DT-6. The
steel used for the drives has been chosen because of their high tensile force, toughness and
resistance to bending. The mechanical drive accommodates both the operates axles (LBS and
earth) and the interlocks. The spring type drive operates independently of the operator and
does not allow any function violation. The switch position indicator shows at any time the
real status of the switch. The forces needed to control the mechanism are low which results
in a high user-friendliness. The drive can be motorized and can receive a number of options
and allows remote control, remote position indication and integration into a SCADA operated
network.
30
DR-6/DT-6
Cable connection
The cables are connected to the cubicles by means of bushings with M16 screwed contacts
and for connectors according to EN 50 181 / DIN 50 standards. They may be of the type A/B or
C (200, 400 630A) and they are defined in function of their applications.
The cable compartment size allows one connector per bushing with a maximum of 400mm2
per cable (on request, lightning arrestors can also be accommodated in the cable box as well as
two cables per bushing).
The extensibility concept
Extensibility of the ring main unit is ensured by top placed bushings of the C- type.
An insulated and screened extension device connects the two sets to be extended. Extension
requires no special tooling nor special on site condition.
The bushings are directly moulded on a stainless steel plate avoiding any risk of leakage caused
by mechanical assembly.
The synoptic diagram and the accessories
A clear, logic and well understandable synoptic diagram is placed in front of each of the
functions. This diagram also supports the voltage indicator of the type HR-3, showing the
presence of the voltage on the cables and allowing the use of phase concordance units.
Short circuit indicators can find their place in the LV compartment and the associated ring type
CT’s in the cable box. Complementary accessories can be accommodated in a well designed LV
box to be placed on the top of the concerned function(s).
IEC 62271-102
HV AC disconnectors and earthing
switches
IEC 62271-105
HV AC Fuse switch combination
IEC 62271-100
HV AC circuit breakers
IEC 62271-1
Common specifications for HV
switchgear and controlgear
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
9
1
2
3
4
5
6
7
8
IEC 62271-200
AC metal enclosed switchgear and
controlgear above 1kV up to 52 kV
Protection relay
The self powered digital protection relay has a
wide range of protection functions, is equipped
with four outgoing contact points and two free
programmable outgoing points. The relay functions
are easy accessible and programmable with the help
of a laptop or with the support of the menu oriented
interface.
+
Applicable standards
0
RP600
The enclosure
The stainless steel enclosure is manufactured on
brand new, up to date machines associating laser
cutting, robotised bending and 3-D laser welding.
The welded tank is sealed for life and tested under
vacuum, in strict conditions with experienced
equipment. The enclosure accommodates the
life components and is foreseen of a rupture disk
avoiding any problem in the improbable case of an
internal overpressure.
IEC 61243-5
Voltage detection systems (VDS)
31
DR-6/DT-6
ELECTRICAL CHARACTERISTICS
Rated voltage
General specifications
Impulse withstand voltage 1.2 / 50 µsec.
To earth and between phases
Over the insulation distance
Power frequency voltage test 1 min.
To earth and between phases
Over the insulation distance
Rated frequency
Rated current
Rated short time current 1 sec.
Rated peak value of the current
Breaking capacity (IEC 62271-103)
Rated current
Closed loop
No load cable
Earth leakage fault
Internal arc 1 sec. IEC 62271-200 (5 criteria)
Degree of protection
HV-compartment
LV- and cable compartment
Rated gas pressure at 20°C
Line Feeder
Rated current
Rated short time current 1 sec.
Rated peak value of the current
Transformer feeder
Rated current
Fuse switch
Short circuit breaking capacity (limited by the fuse)
Making capacity
Circuit breaker
Short circuit breaking capacity 1 sec.
Making capacity
Number of makings
kV
12
12 Utilities Specifications
24
kV
kV
75
85
95
110
125
145
kV
kV
Hz
A
kA
kÂ
28
32
38
45
50/60
50
60
A
A
A
A
kA
630
630
30
100
20
630
25
63
400/630
12.5/16/20
40/50
20
50
Class E3
630
630
30
100
20
400/630
400/630
30
100
20
IP6X
IP4X
0.3 bar overpressure
Bar
A
kA
kÂ
630
25
63
630
20
50
630
12.5/16/20
31.5/40/50
A
200
200
200
kA
kÂ
25
63
25
63
16/20
40/50
kA
kA
20
63
20
50
5
16
50
FUSE SELECTION TABLE
Standard
UTE
DIN 10
DIN 20
32
kV
10
15
20
10
11
13.8
15
20
22
Power of the distribution transformer (kVA)
100
125
160
200
250
16
16
31.5
31.5
31.5
16
16
16
16
16
16
16
16
16
16
16
20
25
25
31.5
16
20
20
25
25
10
16
16
20
25
10
10
16
20
25
10
10
16
16
20
10
10
10
16
16
315
63
43
16
40
40
31.5
31.5
25
20
400
63
43
43
50
40
40
31.5
25
25
500
63
43
43
50
50
40
40
31.5
31.5
630
63
43
43
63
50
50
50
40
40
800
1000
1250
43
43
80
63
50
50
40
40
63
43
100
80
63
63
63
50
63
125
100
100
80
63
63
1600
2000
125
100
80
80
100
100
DR-6/DT-6
DIMENSIONS AND DESCRIPTIONS
DR-6C 2KT
DR-6E-2KT
DR-6C 2K
DR-6C 2K2T
I>I>>
I>I>>
DR-6C 3KT
DR-6C 3KD
DR-6C 2KD
DR-6E-2KD
DR-6E EXTENSIBLE FUNCTIONAL UNITS
FUNCTION DESCRIPTION
K - Incoming/ outgoing cubicle
T - Fuse protection cubicles (combined
D - Circuit breaker cubicle
C - Metering cubicle gas insulated
I>I>>
DR-6 2E K
DR-6 2E T
DR-6 2E D
DR-6 2E C
DR-6E EXTENSIBLE FUNCTIONAL UNITS
DR-6C/DR-6E COMPACT
- NON EXTENSIBLE/EXTENSIBLE RING MAIN UNITS
Type
Height
Width
Depth
Weight
Type
Height
Width
Depth
Weight
DR-6C 2K
1410 mm
600 mm
720 mm
280 kg
DR-6E K
1460 mm
300 mm
720 mm
140 kg
DR-6C 2KT
1410 mm
950 mm
720 mm
450 kg
DR-6E T
1460 mm
350 mm
720 mm
180 kg
DR-6E 2KT
1460 mm
950 mm
720 mm
470 kg
DR-6E D
1460 mm
350 mm
720 mm
210 kg
DR-6C 2K2T
1410 mm
1300 mm
720 mm
640 kg
DR-6E C
1460 mm
500 mm
720 mm
240 kg
DR-6C 3KT
1410 mm
1250 mm
720 mm
600 kg
­DT-6C 2KD
1420 mm
950 mm
838 mm
530 kg
DT-6E 2KD
1460 mm
950 mm
838 mm
550 kg
DT-6C 3KD
1460 mm
1250 mm
838 mm
660 kg
The functional units are always extendable to the left or the right of the multifunctional unit.
The multifunctional units are always extendable in both directions.
33
DW-2
WITHDRAWABLE SWITCHGEAR
DW-2
A family of air-insulated fully withdrawable medium
voltage switchgear solutions for indoor installations.
DW-2’s modular design allows you to create rational,
economical and custom-made combinations of medium
voltage cubicles (up to 12kV).
34
DW-2
Type tests
DW-2 switchgear solutions are all fully type tested according
to IEC 62271-200:
•
•
•
•
•
•
•
Short time and peak withstand current
Temperature rise and main circuit impedance
Dielectric test on main and auxiliary circuits
Making and breaking capacity of the circuit breaker within
the panel
Earthing switch making capacity
Mechanical operations
Internal arc fault (IAC classified: AFLR, 31.5A/1s)
Availability and partition
DW-2 switchgears are designed in compliance to availability
classes LSC2B and partition class PM according to
IEC 62271-200.
The switchgear compartments do not need any tools for
opening. Interlocks allow access only when the corresponding
high voltage parts are dead and earthed. Metallic shutters and
partitions segregate the compartments from each other. When
a compartment is opened all other panels in the installation
and all cable termination compartments (including that in the
panel concerned) remain in operation.
Internal arc fault test, 31.5kA/1s
35
DW-2
COMPARTMENTS
36
LOW-VOLTAGE COMPARTMENT
The protection relays that controls the circuit breaker and
accessories, such as the auxiliary contacts, and minimum
voltage relays, are also located in this compartment. The
compartment can be accessed very easily by opening the
compartment door.
LOW-VOLTAGE COMPARTMENT
BUSBAR COMPARTMENT
SWITCHGEAR COMPARTMENT
BUSBAR COMPARTMENT
The busbar compartment is located in the back side of the
cubicle and behind the low-voltage compartment. The
modular busbar set is manufactured from specially provided
electrolyte F25 copper. Several cubicles are connected
through the bar set compartments. Hexagonal bolts connect
the busbars to the upper contact surfaces of the fixed
contacts in the insulators.
CABLE COMPARTMENT
The cable compartment is located behind the interlocked,
removable door of the DW-2 cubicle. This part accepts the
cable(s) and contains the necessary equipment to connect
the cable(s). The earthing switch is installed below the circuit
breaker switch on the back side, ensuring a “visible earthing”
when the earthing switch is closed. The door and the sectional
floor panels, which house the necessary conductive rubber
for the cables, and the cable supports, all simplify the cable
connection.
CABLE COMPARTMENT
SWITCHGEAR COMPARTMENT
In this compartment, the withdrawable magnetic driven
vacuum circuit breaker switch, acts as the physical separation
between the busbar set and the cable compartment. The
switch has two functions: it connects or interrupts the electrical
current between the high voltage cables and the busbar.
DW-2
TECHNICAL SPECIFICATIONS
Rated Data
Rated Voltage
12kV
12 Utilities Specifications
Rated power frequency withstand voltage (Ud)
28kV
42kV on request
Rated lightning impulse withstand voltage (peak)
75kV
95kV on request
Rated short-circuit breaking current (Isc)
to 31.5kA
to 31.5kA
Rated peak withstand current (Ip)
to 82kA
to 82kA
Rated short-time withstand current (Ik)
to 31.5kA
to 31.5kA
Rated duration of short circuit current (tk)
4s
4s
Internal arc withstand current, 1s
31.5kA
31.5kA
Rated frequency
50/60Hz
50/60Hz
Rated busbar current
2500A
2500A
Rated feeder current
630A, 1250A, 1600A, 2000A
630A, 1250A, 1600A, 2000A
IEC 62271-200
IEC 62271-200
Degree of protection (RC 630A, 1250A)
IP4X
IP4X
Degree of protection (RC 1600A, 2000A)
IP3X
IP3X
-25…+40 °C
-25…+40 °C
95%
95%
1000m a.s.l.*
1000m a.s.l.*
Standards
Temperature range
Maximum relative humidity
Maximum altitude
Notes:
* For installations at altitudes higher than 1000m, the insulation withstand level of external insulation at the service location has to be determined by multiplying the rated
insulation levels by a factor Ka in accordance to IEC 62271-1.
37
DW-2
DW-2 MODULES
38
Withdrawable circuit breaker panel with optional earthing switch - DW-2-IF
PAGE 39
Busbar riser with optional VT - DW-2-BR
PAGE 40
Bustie with optional CT and earthing switch - DW-2-BT
PAGE 41
VT panel with optional earthing switch - DW-2-M
PAGE 42
Incoming feeder connection panel - DW-2-DIF
PAGE 43
DW-2
WITHDRAWABLE CIRCUIT BREAKER WITH Optional EARTHING SWITCH
DW-2-IF
Application
Incoming/outgoing feeder with optional earthing switch.
Specifications & Dimensions
Rated current
A
630 - 1250
1600-2000
Height
mm
2200
2200
Height with arc venting shields
mm
2500
2600
Height with gas exhaust duct
mm
2600
2600
Width
mm
650/800
800
Depth
mm
1260
1260
Possible Configurations
39
DW-2
Bus riser WITH OPTIONAL VT
DW-2-BR
Application
Cubical for rising bus from bottom to top/or top to bottom with optional VT for metering or
auxiliary voltage supply.
Specifications & Dimensions
Rated current
A
630 - 1250
1600-2000
Height
mm
2200
2200
Height with arc venting shields
mm
2500
2600
Height with gas exhaust duct
mm
2600
2600
Width
mm
650/800
800
Depth
mm
1260
1260
Possible Configurations
40
DW-2
Bus TIE with optional ct and earthing switch
DW-2-BT
Application
Bus tie with optional earthing switch for earthing one side of bus tie. Optional CT for metering
requirements.
Specifications & Dimensions
Rated current
A
630 - 2000
Height
mm
2200
Height with arc venting shields
mm
2500
Height with gas exhaust duct
mm
2600
Width
mm
650/800
Depth
mm
1260
Possible Configurations
41
DW-2
VT PANEL with optional earth switch
DW-2-M
Application
Voltage Source or metering voltage tap with optional earthing switch.
Specifications & Dimensions
Rated current
A
630 - 2000
Height
mm
2200
Height with arc venting shields
mm
2500
Height with gas exhaust duct
mm
2600
Width
mm
650/800
Depth
mm
1260
Possible Configurations
42
DW-2
incoming feeder connection panel
DW-2-DIF
Application
Incoming cable connecting metering with optional earth switch, CT’s and VT’s.
Specifications & Dimensions
Rated current
A
630 - 1250
1600-2000
Height
mm
2200
2200
Height with arc venting shields
mm
2500
2600
Height with gas exhaust duct
mm
2600
2600
Width
mm
650/800
800
Depth
mm
1260
1260
Possible Configurations
43
DI-2
GAS INSULATED SWITCHGEAR
DI-2
A modular concept combining all medium-voltage
functions.
DI-2’s modular design allows you to create rational,
economical and custom-made combinations of
medium-voltage cubicles (with a rated voltage of up to 36kV)
44
DI-2
TECHNICAL SPECIFICATIONS
Rated Voltage
kV
Up to 36
- To earth and between phases
kV
170
- Over the insulated distance
kV
195
- To earth and between phases
kV
70
- Over the insulated distance
kV
80
Rated frequency
Hz
48/62
Rated current
A
400/630
Rated short-time current 3s.
kA
20
Rated peak value of the current
kÂ
50
- Mainly active load current (I1 / Iloop)
A
400/630
- Closed loop current (I2A / Iloop)
A
630
- Cable charging current (I4A/ICC)
A
25
A
2
- Short circuit making current (Ina)
kÂ
50
- Earth fault current (I6a/Ief1)
A
50
- Cable and line charging current under earth faults (I6b / Ief2)
A
16
Impulse withstand voltage 1.2 / 50 μs
Power frequency withstand voltage:
Breaking capacity RV36 (Class E3)
(I4B)
Degree of protection
Mechanical durability c/o
IP2X
1000 (=M1)
Standards
IEC 62271-100, IEC 62271-1, 62271-102,
-103, -105, 62271-200
and IEC 61243-5
Certificates
KEMA/IPH
45
DI-2
DI-2 MODULES
46
Load break switch and interlocked earthing switch - DI-A
PAGE 62
Load break switchfuse combination - DI-P
PAGE 63
Protection cubicle with load break switch and vacuum circuit breaker - DI-D
PAGE 64
DI-2
LOADBREAK SWITCH AND INTERLOCKED EARTHING SWITCH
DI-A
Application
Incomer or feeder cable connection cubicle.
Standard Equipment
• Three-phase load break switch RV36, class E3 according to IEC 62271-103, gas insulation
• Integrated interlocked earthing switch with making capacity up to 50kA
• Cable support
• Door interlock
• Sockets for capacitive voltage detector with parallel testing possibility
• Low-voltage compartment
Options
• Set of auxiliary contacts on load break switch
• Set of auxiliary contacts on earthing switch
• Key interlock on load break switch and/or earthing switch
• Motor operation: 24-48-110V-DC of 110-220VAC
• Short-circuit indicator (to be specified by the customer when the order is placed)
• Voltage indicators
• Plinth: 200mm - 400mm
Specifications & Dimensions
Rated Voltage
kV
36
Rated current
A
630
Short-term current
kA
20
s
3
Width
mm
418
Depth
mm
760
Height
mm
1790
Height between ground and end
socket
mm
790
Height between ground and cable
support
mm
310
kg
225
Time of the short duration of current
Weight
IAC AFL
16kA - 1s
47
DI-2
load break switchfuse combination
DI-P
Application
Transformer protection and Medium Voltage equipment protection.
Standard Equipment
• Three-phase load break switch RV36, class E3
according to IEC 62271-105, gas insulation
• Double earthing switch with mutual interlock
• Socket for HRC fuses:
• Door interlock
• Sockets for capacitive voltage detector
• Low-voltage compartment
• Three phase tripping in case of fuse trip
Options
• Set of auxiliary contacts on load break switch and/or earthing switch
• Key interlock on load break switch and/or earthing switch
• Shunt trip *
• Under voltage release *
• Closing release *
• Motor operation *
• HRC fuses and/or spare fuses
• Contact “fuse blown”
• Automatic recloser
• Set of 2 or 3 voltage transformers
• Voltage indicators
• Plinth: 200mm - 400mm
Specifications & Dimensions
Rated Voltage
kV
36
Rated current
A
630
Short-term current
kA
20
s
3
mm
524
Time of the short duration of current
Width
Depth
mm
950
Height
mm
1790
Height between ground and end
socket
mm
790
Height between ground and cable
support
mm
310
kg
250
Weight
IAC AFL
48
16kA - 1s
DI-2
Protection cubicle with LOAD BREAK
SWITCH AND VACUUM CIRCUIT BREAKER
DI-D
Application
Protection of descending feeders with circuit breaker, transformer and Medium Voltage
equipment protection.
Standard Equipment
• Three-phase load break switch RV36, class E3 according to IEC 62271-103, gas insulation
• Vacuum circuit breaker with integrated protection relay, current transformers and release
• Interlocked earthing switch with rated making capacity up to 50kA downstream of the
capacity switch
• Cable support
• Door interlock
• Sockets for capacitive voltage detector
• Voltage indicators
• LV compartment
Options
• Set of auxiliary contacts on the load break switch and/or earthing switch
• Key interlock on load break switch and/or earthing switch
• Motor operation on load break switch: 24-48-110VAC/DC and 220VAC
• Short-circuit indicator (to be specified by the customer)
• Earthing connections upwards from the circuit breaker
• Voltage indicators
• Plinth: 200mm - 400mm
Specifications & Dimensions
Rated Voltage
kV
36
Rated current
A
630
Short-term current
kA
20
s
3
Width
mm
600
Depth
mm
1047
Height
mm
1790
Height between ground and end
socket
mm
790
Height between ground and cable
support
mm
310
kg
352
Time of the short duration of current
Weight
IAC AFL
16kA - 1s
49
DF-3
COMPACT AIR INSULATED SWITCHGEAR
DF-3
The safe, compact and environmentally concious Medium
Voltage Switchgear cubicle.
The DF-3 has extendable switchgear with three functional gas
insulated load break switch and associated mechcanical drives.
50
DF-3
The new modular and extendable switchgear
DF-3
THE CONCEPT
DF-3
•
•
•
•
•
Gas insulated three-functional (ON/OFF/EARTH) load break switch and associated
mechanical drives
Up to 24kV insulation voltage level - 800/630A
Air insulated cable and busbar compartment
PI/LSC2A/IAC AFL 16 KA (AFLR - optional)/E3/M1 according to IEC 62271 (100/102/103/105/200)
Integrated voltage presence indicators with phase comparison possibility (IEC 61243-5)
Clear and visible single line diagram with functional integrated interlocking
HR
DEBA COMPONENTS
1400
•
THE ADVANTAGES
•
•
•
•
•
•
•
•
•
Developed and manufactured in line with the ISO 9001 standards
Reduced sizes (hxlxp - 1400 (1700)mm x 375 (500)mm x 900mm) very near of the compact
full gas insulated designs factory tested
Mechanical spring operated drives with numbers of options for Scada applications and
remote control
Galvanised steel construction
Reduced on site installation time and possibility of extension at any time
Conventional cable connections
Exceptional accessibility to all components of the cable compartment
Easy op operate, reliable and safe for the operator
Maintenance free
375/500
DF-3 A
DF-D-500
DF-3 P
51
DF-3
COMPARTMENTS
52
LOW-VOLTAGE COMPARTMENT
The drive mechanism that controls the RV53 load break
switch and the integrated earthing switch is fitted with the
synoptic diagram and is located behind the front panel.
Several accessories such as the auxiliary contacts, switch-on or
switch-off coils, and minimum voltage relays, are also located
in this compartment. An optional motorized drive mechanism
with all the necessary control elements could also be installed
in this compartment. The compartment can be accessed very
easily by disassembling the front panel. Optional padlocks
prevent unauthorised access.
LOW-VOLTAGE COMPARTMENT
BUSBAR COMPARTMENT
SWITCHGEAR COMPARTMENT
BUSBAR COMPARTMENT
The busbar compartment is located in the upper part of
the cubicle and behind the low-voltage compartment. The
modular busbar set is manufactured from specially provided
electrolyte F25 copper Ø27mm (IrBB=630A). Various cubicles are
connected through busbar compartments. Hexagonal bolts
connect the busbars to the upper contact surfaces of the RV53
load break switch.
CABLE COMPARTMENT
The cable compartment is located behind the interlocked,
removable door of the DF-3 cubicle. This part of the cubicle
accommodates the cable(s) and contains the necessary
equipment to connect the cable(s). In a DF-A cubicle, the
cables are connected to the contact points below the
RV53 load break switch. The cables of the DF-P cubicles are
connected to the lower fuse base side. This type of cubicle
also has an additional auxiliary earthing switch to divert any
residual current. DF-D types have the earthing located in the
cable compartment below the circuit breaker. The removable
door, the sectional floor panels, which house the necessary
conductive rubber for the cables, and the cable supports, all
simplify the cable connection.
CABLE COMPARTMENT
SWITCHGEAR COMPARTMENT
In this compartment, the gas filled RV53 three position load
break switch acts as the physical separation between the busbar
set and the cable compartment. The switch has three functions:
it connects or interrupts the electrical current between the high
voltage cables and the busbar. Additionally, the earthing switch
is integrated.
DF-3
TECHNICAL SPECIFICATIONS
Rated Voltage
kV
12
12 *
24
- To earth and between phases
kV
75
95
125
- Over the insulated distance
kV
85
110
145
- To earth and between phases
kV
28
38
50
- Over the insulated distance
kV
32
45
60
Rated frequency
Hz
50/60
50/60
50/60
Rated current
A
630
630
630
Rated short-time current 1s.
kA
20
20
20
Rated peak value of the current
kÂ
50
50
50
- Mainly active load current (I1 / Iloop)
A
630
630
630
- Closed loop current (I2A / Iloop)
A
630
630
630
- Cable charging current (I4A/ICC)
A
16
16
16
(0,2-0,4 I4A / 0,1-0,4 ICC)
A
5
5
5
- Short circuit making current (Ina)
kA
50
50
50
- Earth fault current (I6a/Ief1)
A
100
100
100
- Cable and line charging current under earth faults (I6b / Ief2)
A
30
30
30
Impulse withstand voltage 1.2 / 50 μs
Power frequency withstand voltage:
Breaking capacity RV53 (Class E3)
Degree of protection
IP4X
Mechanical durability c/o
1000
Standards
IEC 62271-100, IEC 62271-1, 62271-102,
-103, -105, 62271-200
and IEC 61243-5
Certificates
KEMA/IPH
* Utilities Specifications
53
DF-3
DF-3 MODULES
54
Load break switch and interlocked earthing switch - DF-A/DF-A+
PAGE 55
Load break switchfuse combination - DF-P
PAGE 56
Protection cubicle with vacuum circuitbreaker and integrated protection relay -DF-D
PAGE 57
Metering cubicle - DF-C-750
PAGE 58
Cable cubicle and/or bus zone - DF-K
PAGE 59
DF-3
LOAD BREAK SWITCH AND AIR INTERLOCKED EARTHING SWITCH
DF-A
DF-A+ (12 kV Only)
Application
Supply cable connection
Standard Equipment
• Three phase load break switch RV53, class E3
according to IEC 62271-103, gas insulation
• Integrated interlocked earthing switch with making
capacity up to 50kA
• Cable support
• Door interlock
• Sockets for capacitive voltage detector with
parallel testing possibility
• Low-voltage compartment
Options
• Set of auxiliary contacts on load break switch and\or earthing switch
• Key interlock on load break switch and\or earthing switch
• Motor operation: 24-48-110V-DC of 110-220VAC
• Short-circuit indicator (to be specified by the customer when the order is placed)
• Voltage indicators
• Plinth: 200mm - 400mm
Specifications & Dimensions
Rated Voltage
kV
12
12*
24
Rated current
A
630
630
630
Short-term current
kA
20
20
20
s
1
1
1
Width
mm
375/500
375/500
500
Depth
mm
950
950
950
Height
mm
1400
1400
1400
Height between
ground and end
socket
mm
790
790
790
Height between
ground and cable
support
mm
310
310
310
kg
115/140
115/140
140
Time of the short
Duration of current
Weight
IAC AFL
DF-C-500
14 kA - 1s
DF-C-750
55
DF-3
load break switchfuse combination
DF-P
Application
Transformer protection and Medium Voltage equipment protection.
Standard Equipment
• Three phase load break switch RV53, class E3
according to IEC 62271-105, gas insulation
• Double earthing switch with mutual interlock
• Socket for HRC fuses:
- e = 292mm DIN 10 at 17.5kV
- UTE
• Door interlock
• Sockets for capacitive voltage detector
• Low-voltage compartment
• Three phase tripping in case of fuse trip
Options
• Set of auxiliary contacts on load break switch and\or earthing switch
• Key interlock on load break switch and\or earthing switch
• Shunt trip **
• Under voltage release **
• Closing release **
• Motor operation **
• HRC fuses and/or spare fuses
• Contact “fuse blown”
• Automatic recloser
• Set of 2 or 3 voltage transformers
• Voltage indicators
• Plinth: 200mm - 400mm
Specifications & Dimensions
Rated Voltage
kV
12
12*
24
Rated current
A
630
630
630
Short-term current
kA
20
20
20
Time of the short
duration of current
s
1
1
1
Width
mm
375
375
375
Depth
mm
950
950
950
Height
mm
1400
1400
1400
Height between
ground and end
socket
mm
330
330
330
Fuse size
mm
292 (DIN)
292 (DIN)
292 (DIN)
kg
134
134
134
Weight
56
DF-3
Protection cubicle with vacuum circuit breaker and
integrated protection relay
DF-D
Application
Protection of descending feeders with circuit breaker, transformer and Medium Voltage
equipment protection.
Standard Equipment
• Three-phase load break switch RV53, class E3 according to IEC 62271-103, gas insulation
• Vacuum circuit breaker with integrated protection relay, current transformers and release
• Interlocked earthing switch with rated making capacity up to 63kA
• Cable support
• Door interlock
• Sockets for capacitive voltage detector
• Voltage indicators
• LV compartment
Cubicle Options
• Set of auxiliary contacts on load break switch and\or earthing switch
• Key interlock on load break switch and\or earthing switch
• Motor operation on load break switch: 24-48-110VAC/DC and 220VAC
• Short-circuit indicator (to be specified by the customer)
• Earthing connections upwards from the circuit breaker
• Circuit breaker gas insulated
• Voltage indicators
• Plinth: 200mm - 400mm
Options on the circuit breaker
• Motor operation **
• Closing release
• Shunt trip **
• Under voltage release **
• Set of auxiliary contacts
• Error contact
• Supply for test protective relay (battery block)
• Switch counter
• Automatic recloser
• Button press control on circuit breaker
• Remote control on circuit breaker
• Key interlock
Specifications & Dimensions
Rated Voltage
kV
12
12*
24
Rated current
A
630
630
630
Short-term current
kA
20
20
20
Time of the short
duration of current
s
1
1
1
Width
mm
675
675
675
Depth
mm
950
950
950
Height
mm
1500
1500
1500
Height between
ground and socket
mm
360
360
360
kg
460
460
460
Weight
57
DF-3
Metering cubicle
DF-C-750
Application
The DF-C-750 cubicle has been designed for positioning current and voltage transformers to
measure energy consumption.
Standard Equipment
• 3 Ti’s xA => 5A
• 3 Tp’s xV => 110V, V3
Options
• Additional current transformers
• Additional voltage transformer with or without Medium Voltage and LV protection
• Support for the positioning of measuring transformers
• Measuring system with 3 CTs and 3 VTs
• Measuring system with kWh metering and Kvarh metering
(requirements to be specified by the customer)
• Current measurement system
• Voltage measurement system
• Plinth: 200mm - 400mm
• Low voltage compartment safety box to secure voltage circuits
Possible connections:
• Bottom left in - bottom right out
• Bottom right in - bottom left out
• Bottom left in - top right out
• Bottom right in - top left out
• Top right in - top left out
• Top left in - top right out
Specifications & Dimensions
Rated Voltage
kV
12
24
Rated current
A
up to 630
up to 630
Short-term current
kA
20
20
Time of the short
duration of current
s
1
1
Width
mm
750
750
Depth
mm
950
950
Height
mm
1400
1400
kg
55
55
Weight**
** Without equipment
58
DF-3
Cable cubicle and/or Bus zone
DF-K
Application
Cubicles of the DF-3 type are equipped to bring in a supply cable, however a DF-K cubicle can
also contain a busbar and can be used as rising cubicle of the rail set.
Standard Equipment
• Three-phase load break switch RV53, class E3 according to IEC 62271-103, gas insulation
• Vacuum circuit breaker with integrated protection relay, current transformers and release
• Interlocked earthing switch with rated making capacity up to 63kA
• Cable support
• Door interlock
• Sockets for capacitive voltage detector
• Voltage indicators
• LV compartment
Options
• Holder for capacitive voltage indicators
• Capacitive voltage indicators
• Short-circuit detectors (to be specified by the customer when ordering)
• Earthing switch
• Set of auxiliary contacts on earthing switch
• Key interlock on earthing switch
• Earthing ball clamps
• Current transformers in the busbar
• Voltage transformers with of without protection in the busbar
• Plinth: 200mm - 400mm
Possible connections:
• Bottom in - top out
• Bottom in - top left out
• Bottom in - top right out
Specifications & Dimensions
Rated Voltage
kV
12
12*
24
Rated current
A
up to 630
up to 630
up to 630
Short-term current
kA
up to 20
up to 20
up to 20
Time of the short
duration of current
s
1
1
1
Width
mm
M
M
M
Depth
mm
950
950
950
Height
mm
1400
1400
1400
kg
55
55
55
Weight (**)
59
Scan the QR code
to download the
eCatalogues App
AUSTRALIA
New South Wales
Queensland
Sydney
30-34 Day Street North
Silverwater
NSW 2128
Tel +61 2 9748 3444
Brisbane
16 Riverview Place
Murarrie
QLD 4172
Tel +61 7 3909 4999
Melbourne
43-67 River Street
Richmond
VIC 3121
Tel +61 3 9429 2999
Newcastle
575 Maitland Road
Mayfield West
NSW 2304
Tel +61 2 4960 2220
Fax +61 2 4960 2203
Townsville
5 Leyland Street
Garbutt
QLD 4814
Tel +61 7 4779 0700
Fax +61 7 4775 1457
Laverton
104-106
William Angliss Drive
Laverton North
VIC 3026
Tel +61 3 9368 2901
Wollongong
34 Industrial Road
Unanderra
NSW 2526
Tel +61 2 4272 5763
Fax +61 2 4272 5957
Rockhampton
1 Lawson Street
Parkhurst
QLD 4702
Tel +61 7 4927 2277
Fax +61 7 4922 2947
nhp.com.au
SALES 1300 NHP NHP
FAX 1300 NHP FAX
Victoria
Albury / Wodonga
847 Ramsden Drive
Albury
NSW 2640
Tel +61 2 6049 0600
Fax +61 3 6025 0592
Dandenong
40-42 Cyber Loop
Dandenong South
VIC 3175
Tel +61 3 8773 6400
Fax +61 3 8768 8522
Tasmania
Hobart
29B Lampton Ave
Derwent Park
TAS 7009
Tel +61 3 6228 9575
Fax +61 3 6228 9757
Launceston
Unit 3
13-17 Merino Street
Kings Meadows
TAS 7249
Tel +61 3 6345 2600
Fax +61 3 6344 6324
ACT
Canberra
Unit1
187 Gladstone Street
Fyshwick
ACT 2609
Tel +61 2 6280 9888
Fax +61 2 6280 9588
Western Australia
Perth
38 Belmont Ave
Rivervale
WA 6103
Tel +61 8 9277 1777
Northern Territory
Darwin
3 Steele Street
Winnellie
NT 0820
Tel +61 8 8947 2666
Fax +61 8 8947 2049
NHP Electrical Engineering Products Pty Ltd
A.B.N. 84 004 304 812
NMVSWITCHGEARC 0713 © Copyright NHP 2013
Toowoomba
Cnr Carroll Street and
Struan Court
QLD 4350
Tel +61 7 4634 4799
Fax +61 7 4633 1796
Cairns
Unit 2
1 Bramp Close
Portsmith
QLD 4870
Tel +61 7 4035 6888
Fax +61 7 4035 6999
South Australia
Adelaide
36-38 Croydon Road
Keswick
SA 5035
Tel +61 8 8297 9055
NEW ZEALAND
nhp-nz.com
SALES 0800 NHP NHP
FAX 0800 FAX NHP
PO Box 62-009
Sylvia Park
Auckland 1644
New Zealand
Auckland
118a Carbine Road
Mt Wellington 1060
Hamilton
78 Rostrevor Street
Hamilton 3204
Napier
126 Taradale Road
Onekawa 4110
New Plymouth
2 Dean Place
Waiwhakaiho 4312
Wellington
52 Victoria Street
Lower Hutt 5010
Christchurch
27 Iversen Terrace
Waltham 8011
Dunedin
30 Fox Street
South Dunedin 9012