Induction_Lighting_D.. - Eco

advertisement
Integrated
Lighting
Controls —
Increasing Market
Demand for Your Fixtures
FS S E R I E S O C C U PA N CY S E N S O R S FO R LU M I N A I R E S
PUTTING A STOP TO ENERGY WASTE
Increase Demand for Your
Fixtures with Easy-to Integrate
Watt Stopper FS
Occupancy Sensors
Watt Stopper/Legrand, the market leader
Watt Stopper FS Fixture Sensors add the
in energy-efficient lighting controls,
most value:
teams with fixture manufacturers to
Small footprint, with an architecturally
produce more competitive products for
today’s
marketplace.
Partner with the
With our full line
leader committed
of fixture
to “Putting a Stop
sensors, you can
to Energy Waste”
pleasing appearance that easily
integrates into a wide range of fixture
types
Modular plug-in system which utilizes
an RJ45 connection for installation
integrate
superior lighting control technology into
your new luminaires, creating highdemand products without losing focus of
your core competency — manufacturing
quality fixtures.
The rising cost of
electricity creates a
Energy
demand for energysavings
efficient luminaires
that maximize
savings on your
utility bill. Watt Stopper fixture
sensors have features, such as
integrated force-off daylighting, that
enable significant energy savings.
flexibility and ease of use
Adjustable time delay feature (included
in all models)
Available in line and low voltage
models and multiple sensing
technologies to provide the right
control for each application
Widespread
adoption of strict
energy codes
throughout North
America has
created demand for
products that comply with IECC,
ASHRAE/IESNA Standard 90.1 and
California Title 24. Integrating Watt
Stopper occupancy sensors into your
fixtures help them comply to code.
Code
compliance
More specifiers,
building owners and
Sustainability facility managers
are looking for
products that
embrace ‘green’
building practices such as LEED,
and many local utilities offer rebate
incentive programs. Integrating
Watt Stopper fixture sensors into
your products lets you capitalize on
this growing demand.
CONTROLLED BY
Watt Stopper's Services Will
Develop and Grow Your Business
Engineering
Purchasing
Advanced product design processes with
Our dedicated OEM Customer Service
comprehensive on-line engineering
Department offers speedy order processing,
resources can be downloaded, such as CAD
24-hour turnaround on order shipping, and
dimensional drawings, coverage patterns and
convenient on-line order tracking and
wiring diagrams.
account access.
Common Applications for
Watt Stopper FS Series
Sensors
Small Office or Cubicle:
FS-105, -205, -405
Storage/Utility Room, Closet:
FS-105, -205, -305. -405
Manufacturing
Sales
No need to retool your manufacturing facility
Watt Stopper/Legrand is the marketplace
— our sensors easily incorporate into your
leader in brand recognition and sales that
existing manufacturing processes, with
your team can tap into to generate your own
features such as push-in wire connectors or
opportunities and drive sales performance.
Desktop Task Lighting:
FS-155, -255
Technical Support
Restroom:
FS-505, -505C
RJ45 quick connects for rapid installation.
Marketing
Our OEM technical specialists assist with
We provide you with a comprehensive
design and application support.
portfolio of marketing tools, from design &
application guides, ready–to-use promotional
materials and electronic images, to
customized collateral designed by our
marketing professionals.
Stairwell and Hallway:
FS-505, -505C
F I X T U R E
S E N S O R S
FS Low Voltage PIR Fixture Occupancy Sensors
Complete line of occupancy sensors
that integrate into lighting fixtures
for any application
Modular plug system
streamlines installation
Compact lens gives
unobtrusive appearance in
even the smallest fixtures
Turn lights on and off based on
occupancy and daylight level
PROJECT
LOCATION/TYPE
Product
Overview
Description
Applications
The FS Low Voltage Passive Infrared (PIR) Fixture
Sensors control lighting based on occupancy. They are
designed with a low-profile, architecturally pleasing
appearance to easily integrate into a wide range of
lighting fixtures or a customized housing. Additionally,
the FS-105, -205 and -405 have an integrated
photosensor that holds off connected loads when
enough daylight is available to provide additional
energy savings. Sensors’ modular plug-in system
utilizes an RJ45 connector on a low-voltage 6-ft. cord
for installation flexibility, and to quickly link to a
remote-mounted power pack.
The FS-105, -205 and -305 all provide a 360°
coverage pattern for up to 200 square feet when
mounted at 8’, yet have different applications based
on the distinctive mounting options they each
provide. All three work well in a small office,
cubicle or utility room. And if the area has
exposure to daylight, the FS-105 and -205 can
provide additional energy savings by utilizing their
incorporated photosensor to hold off the lights
when there is 10-120 fc of ambient light at the
sensor’s point of installation.
Operation
When connected to an FS-PP Power Pack, the FS105/205/305/405 sensors operate at 24 VDC to
detect occupancy. Utilizing the latest PIR technology
to detect the difference between heat emitted from
the human body in motion and the background
space, the FS sensor signals the FS-PP to close it's
relay and turn on the connected load. After the
defined area is vacated and the adjustable time
delay (30 seconds to 30 minutes) has elapsed, the
sensor signals the FS-PP to open its relay and turn
off the connected load.
The daylighting circuits in the FS-105, -205 and -405
provide additional energy savings. Once the lights
turn off after the time delay has elapsed, the
daylighting circuit will keep the lights from turning
back on upon new occupancy if there is sufficient
ambient light available (adjustable from 10-120 fc) .
Features
• Low-voltage 6-ft. whip with an RJ45 connector for
easy installation
• Small footprint fits easily in fixtures
4
www.wattstopper.com
800.879.8585
• Adjustable time delay (30 seconds to 30 minutes)
The FS-105 is designed to mount remotely from
the fixture(s) in a ceiling tile, and comes with a 6’
whip to connect to its fixture-mounted FS-PP. The
FS-205 is little enough to be easily integrated into
even the smallest housings when zonal control of
direct/indirect fixtures is required. The FS-305 has
a long, threaded body for installation in a fixture
with double-wall thickness where zonal control is
needed for control of direct/indirect fixtures.
Due to its larger Fresnel lens, the FS-405 provides
coverage for an area up to 300 square feet, also in
a 360° coverage pattern, making it ideal for a
medium-size open office or small conference
room, especially one with access to 10-120 fc of
daylight at the sensor’s installation site to utilize its
incorporated photosensor and benefit from
additional energy savings.
• Fresnel lenses for accurate detection patterns
• LED indicator of occupancy detection for easy
verification of coverage
• Hold-off daylighting control in FS-105, -205 and -405
FS-105
Coverage at 8’ ht
14’ diameter (487.7cm)
FS-405
16’ diameter (487.7cm)
16’ diameter (487.7cm)
18’ diameter (609.6cm)
32-131°F (0-55°C)
32-131°F (0-55°C)
32-131°F (0-55°C)
32-131°F (0-55°C)
throat 1” (25.4mm) diam.
collar 1.4” (35.6mm) diam.
length 4” (101.6mm)
throat .75” (19mm) diam.
collar 1.12” (28.5mm) diam.
lens pipe .38” (9.7mm)
body 1.12” x 1.38” x .5”
(28.5mm x 35mm x 12.7mm)
throat .75” (19mm) diam.
collar 1” (25.4mm) diam.
length 2.25” (57.2mm)
throat 1.14” (28.9mm) diam.
collar 1.28” diam.(32.5mm)
lens pipe .38” (9.7mm)
body 1.38” x 2.35” x .88”
(35mm x 59.7mm x 22.4mm)
Time Delay
30 seconds to 30 minutes
30 seconds to 30 minutes
30 seconds to 30 minutes
30 seconds to 30 minutes
Light Level
Hold off adjustable 10-120 fc
Hold off adjustable 10-120 fc
Placement
Ceiling mounted to provide
optimal coverage (load
switching is done by remotemounted power pack
Compact design ideal for lowprofile fixtures
Compact shape ideal for
fixture integration.
Long, threaded body
design ideal for
installation into fixtures
with double wall
thickness
Multiple FS Low Voltage Sensors & Power
Packs in One Fixture or Zone
FS Low Voltage Wiring
Two FS sensors connected to two FS-PP
Standard connection
between FS sensor
and FS-PP
power pack
two FS-CK-1 kits required
(one cable unused)
FS sensor
Wiring &
Coverage
Hold off adjustable 10-120 fc
FS-PP
FS sensor
Dimensions*
S E N S O R S
FS-305
Operating Temperature
FS-205
F I X T U R E
Specifications
FS-PP
Coverage Patterns @ 8 ft Mounting Height
8'
3m
10'
6'
2.4m
8'
4'
2'
FS-105,
0
FS-205,
FS-305
2'
4'
1.2m
4'
FS-405
0m
0ft
1.2m
4'
6'
8'
8'
Ordering
Information
4'
Catalog No.
NOTE:
Pub. No. 26601
6'
2'
0
2'
4'
6'
8'
2.4m
8
3m
10'
3m
10'
2.4m 1.8m
8'
6'
1.2m 0.6m
4'
2'
Description
0m
0ft
0.6m
2'
1.2m 1.8m
4'
6'
2.4m 3m
8'
10'
Load Capacity
FS-105
Low Voltage PIR Ceiling Mount Occupancy Sensor; 24 VDC
Current Consumption 6.5mA
FS-205
Low Voltage PIR Low Profile Fixture Occupancy Sensor, 24 VDC
Current Consumption 6.5mA
FS-305
Low Voltage PIR Cylindrical Body Fixture Occupancy Sensor, 24 VDC
Current Consumption 6.5mA
FS-405
Low Voltage PIR Compact Size Fixture Occupancy Sensor, 24 VDC
Current Consumption 6.5mA
FS-PP
Fixture Power Pack 120/277 VAC; 60Hz
70mA @ 24 VDC
All FS Low Voltage Sensors require an FS-PP or other Watt Stopper Power Pack
(ordered separately) to operate.
www.wattstopper.com
800.879.8585
5
S E N S O R S
FS Line Voltage PIR Fixture Occupancy Sensors
Sensor and relay in one package
F I X T U R E
Fresnel lens for reliable
occupancy detection
6’ flying leads
Front controls with rubber gasket for
flush mounting on curved surfaces
PROJECT
LOCATION/TYPE
Product
Overview
Description
Applications
The FS Line Voltage Passive Infrared (PIR) Sensors
control lighting based on occupancy. They are
designed with a low-profile, architecturally pleasing
appearance to easily integrate into a wide range of
lighting fixtures or a customized housing. Both
provide a sensor and relay in one package, and their
integrated photosensor holds off connected loads
when enough daylight is available to provide
additional energy savings. The FS-155 is equipped
with 6’ flying leads and the FS-255 has terminal
connectors.
The FS-155 provides coverage up to 100 square
feet and FS-255 up to 300 square feet, both in a
360° coverage pattern when mounted at 8’. Both
work well where relay and sensor are required in
one package, and they both can provide additional
energy savings by utilizing their incorporated
photosensor to hold off the lights when there is 10120 fc of ambient light at the sensor’s point of
installation. Their applications vary most by the
distinctive mounting options they each provide.
Operation
The FS-155 and FS-255 operate at 120/277 VAC to
control lighting based on occupancy. Utilizing the
latest PIR technology, which detects the difference
between infrared energy in motion and the
background space, they automatically turn the lights
off after the defined area is vacated and the
adjustable time delay (30 seconds to 30 minutes) has
elapsed. An integrated photosensor will hold off the
lights for additional energy savings if there is 10120fc of ambient light where the sensor is installed.
Features
6
www.wattstopper.com
800.879.8585
The FS-155 has terminal connectors and a rubber
gasket for flush mounting on curved surfaces, and
the FS-255 has 6’ flying leads. Both work well with
desktop task lighting. The FS-155 is also suitable
for cubicles and small offices, and the FS-255 can
provide control in high traffic larger offices with
single sensor to ballast control.
• Sensor and relay in one package
• FS-255 designed with 6’ flying leads
• Hold-off daylighting when placed in areas with
10-120 fc of ambient light
• FS-155 designed with Fresnel lens, terminal
connectors, accessible front controls and rubber
gasket for flush mounting on curved surfaces
Specifications
FS-155 Line Voltage PIR Fixture Sensor
Voltage
Load Req @120
Load Req @277
Time Delay
Light Level
Coverage at 8’ ht
Operating Temp
Color
Dimensions
120/277VAC 60Hz
0-800W ballast or tungsten
0-1200W ballast
30 seconds to 30 minutes
hold-off daylighting from adjustable 10-120 fc
14’ (304.8cm) diameter
32-131°F (0-55°C)
White
lens housing 0.5” (12.7mm) diameter
lens collar 1” (25.4mm) diameter
sensor body 7.1” x .87” x .67” (181mm x 22mm x
17mm)
body 1.38” x 2.35” x .88” (35mm x 59.5mm x 22.3mm)
FS-155 Line Voltage Wiring
FS-255 Line Voltage Wiring
Red – Load
Load
S E N S O R S
Neutral
120/277VAC 60Hz
0-800W ballast
0-1200W ballast
30 seconds to 30 minutes
hold-off daylighting from adjustable 10-120 fc
18’ diameter (548.6cm)
32-131°F (0-55°C)
White
throat 1.14” (28.9mm) diameter
collar 1.28” (32.5mm) diameter
lens pipe length 0.38” (9.7mm)
F I X T U R E
Wiring &
Coverage
FS-255 Line Voltage PIR Fixture Sensor
Line/Hot
Neutral
Load
Black – Hot
Ballast
Load
White – Neutral
Coverage Patterns @ 8’ Mounting Height
(1.5m)
3m
10'
4'
2.4m
8'
5'
(1.2m)
1.2m
4'
2'
(0.6m)
0ft
0m
0ft
(0m)
2'
1.2m
4'
(0.6m)
4'
(1.2m)
2.4m
8
3m
10'
5'
(1.5m)
(1.2m) (0.9m) (0.6m) (0.3m) (0m) (0.3m) (0.6m) (0.9m) (1.2m) (1.5m)
4'
3'
2'
1'
0ft
1'
FS-155
Ordering
Information
Pub. No. 26701
Catalog No.
2'
3'
4'
5'
3m
10'
2.4m 1.8m
8'
6'
1.2m 0.6m
4'
2'
0m
0ft
0.6m
2'
1.2m 1.8m
4'
6'
2.4m 3m
8'
10'
FS-255
Description
FS-155
Line Voltage PIR Fixture Sensor; 120/277 VAC, 12 foot diameter coverage
FS-255
Line Voltage PIR Fixture Sensor; 120/277 VAC, 18 foot diameter coverage
www.wattstopper.com
800.879.8585
7
S E N S O R S
FS Low Voltage Ultrasonic Fixture Occupancy Sensors
Modular plug system
streamlines installation
F I X T U R E
Easily integrate into
lighting fixtures
Ultrasonic technology for
open area detection with
line-of-sight obstructions
Ceiling and wall mount models
Ideal for stairwell, wall and
ceiling mount applications
PROJECT
LOCATION/TYPE
Product
Overview
Description
Applications
The FS Low Voltage Ultrasonic Fixture Sensors
control lighting based on occupancy. They are
designed with a low-profile, architecturally pleasing
appearance to easily integrate into a wide range of
lighting fixtures or a customized housing. The
sensors’ modular plug-in system utilizes an RJ45
connector and 3’ cord for flexibility and ease of use.
Typical applications for the FS-505 Series sensors
include open office cubicles, offices, conference
rooms, restrooms and hallways. This technology
also provides superior detection in hard surfaced
areas, such as stairwells and hallways.
Operation
When connected to an FS-PP Power Pack, the FS505 Series sensors use high frequency (40 kHz)
ultrasonic technology to sense motion within a
space and automatically turn lights on even when
the sensor has no direct line of sight to occupants.
After the area is vacated and the time delay has
elapsed, the sensors automatically turn the lights
off. Ultrasonic detection operates by transmitting
sound waves throughout an area and measuring the
speed at which they return. Movement increases the
return frequency, which triggers occupancy.
For a large rectangular detection area with ceilingmounted fixtures, the FS-505C provides excellent
coverage. For specialized applications such as
stairwells, the elongated coverage pattern of the
FS-505 is ideal.
The FS-505 can provide bi-level lighting control in
fixtures that have bi-level or dimming ballasts,
resulting in up to 66% energy savings for fixtures
that are on 24-hours a day, seven days a week,
while still providing enough light for safety and
egress.
The FS-505 Series sensors provide functions for
testing, overriding the fixture ‘ON’ and a 72-hour
lamp burn-in mode.
Features
8
www.wattstopper.com
800.879.8585
• Ultrasonic technology (40Khz)
• 24 VDC
• Compact design for installation in lowprofile fixtures
• Three modes: override, burn-in and test modes
Current Consumption
Power Supply
Time Delay
Coverage at 8’ ht.
Color
Dimensions*
24VDC
24VDC
43mA
43mA
FS-PP Fixture Power Pack
FS-PP Fixture Power Pack
5-30 minutes
5-30 minutes
24’ (731.5cm) diameter
30’ x 24’ (457.2x365.7cm)
32-131°F (0-55°C)
32-131°F (0-55°C)
White
White
5.2” x 1.25” x .62”
(132.4mm x 32.2mm x 15.7mm)
5.2” x 1.25” x .62”
(132.4”mm x 32.2mm x 15.7mm)
Applications
S E N S O R S
Operating Temp
FS-505C Low Voltage Ultrasonic
Fixture Sensor
F I X T U R E
Voltage
FS-505 Low Voltage Ultrasonic
Fixture Sensor
Wall
Ceiling
FS-505 mounted
in light fixture at
20º from vertical
FS-505
Mounted
in
Stairwell
Door
Specifications
FS-505C in
Pendantmounted
fixture
Landing
FS-505C
FS-PP
Landing
Landing
Wiring &
Coverage
Coverage Patterns @ 8 ft Mounting Height
feet/
meters
3' 6' 9' 12' 15' 18' 21' 24' 27'
0.9 1.8 2.7 3.6 4.5 5.4 6.4 7.3 8.2
feet/
meters
15' (4.5m)
15' (4.5m)
12' (3.6m)
12' (3.6m)
9' (2.7m)
9' (2.7m)
6' (1.8m)
6' (1.8m)
3' (0.9m)
3' (0.9m)
20° from
vertical
12' 9' 6' 3'
3.6 2.7 1.8 0.9
0
3' 6' 9' 12'
0.9 1.8 2.7 3.6
0
3' (0.9m)
3' (0.9m)
6' (1.8m)
6' (1.8m)
9' (2.7m)
9' (2.7m)
12' (3.6m)
12' (3.6m)
15' (4.5m)
15' (4.5m)
18' (5.4m)
FS-505
FS-505C
FS Low Voltage Wiring Example
Standard connection
between FS sensor
and FS-PP
power pack
Ordering
Information
Catalog No.
NOTE:
Description
FS-505
Low Voltage Ultrasonic Fixture Occupancy Sensor for Stairway Applications; 24 VDC fixture mount
FS-505C
Low Voltage Ultrasonic Fixture Occupancy Sensor for Open Areas; 24 VDC fixture mount
FS-PP
Fixture Power Pack 120/277 VAC; 60Hz
All FS Low Voltage Sensors require an FS-PP or other Watt Stopper Power Pack
(ordered separately) to operate.
Pub. No. 26801
www.wattstopper.com
800.879.8585
9
Plug & Play RJ45
Zero Crossing Relay
F I X T U R E
S E N S O R S
FS-PP Fixture Power Pack and Accessories
Normally Open (N/O)/
Normally Closed (N/C)
Relay Options
Terminals for
easy and sure
wire connections
PROJECT
LOCATION/TYPE
Product
Overview
Description
Instant On Feature
The FS-PP Fixture Power Pack provides 24 VDC
operating voltage to the FS Low Voltage Sensors
series via the RJ45 connector built onto each
sensor . The incorporated Form-C Relay, Normally
Open (N/O)/Normally Closed (N/C), can control line
or low voltage loads.
The FS-PP and the FS low voltage sensor
incorporate special electrical circuitry which
ensures that the load connected to it will come
back on after a power failure, and will stay on for
two minutes, unless motion is detected.
Applications
Operation
The FS-PP houses a step-down transformer that
powers the FS sensors, and a relay for switching
the load. Connection to the FS-PP is made by
simply plugging in the RJ45 connector that is
provided at the end of the FS whip. The FS-PP is
rated for 120 or 277V input voltages. The output
power to the sensors is 24VDC, 70mA, which is
capable of powering several sensors (up to seven
FS PIR sensors or one FS Ultrasonic sensor).
The FS-PP is intended for use inside lighting
fixtures in conjunction with an FS Low Voltage
Sensor. Its compact size provides easy installation
into most fixture channels or ballast cavities. The
FS-PP form C relay N/C or N/O provides the
switching options that are needed to control simple
ballast loads, or switching bi-level or dimming
ballast levels.
The RJ45 connector allows easy installation of the
FS Low Voltage Sensors, permitting pre-wiring of
the FS-PP and installation of the sensor later.
The FS-PP uses zero crossing technology on the
N/O side of the relay to increase relay life.
Features
• For use with all Low Voltage Fixture Sensors
• ON/OFF and stepped dimming control options
(with 0-10VDC dimming ballasts)
• Controls: one Ultrasonic or up to seven PIR
Fixture Sensors
• Instant on in the unlikely event of a power
failure
10
www.wattstopper.com
800.879.8585
• RJ45 receptacle for easy plug and play with all
low voltage FS Sensors
• Zero Crossing Circuitry for increased sensor life
• Terminal connections for easy installation
• Small, thin footprint fits in most light fixtures
88T9
Appliance
Control
Ground
GROUND
Com
Neutral
NEUTRAL
COM
N/O
Hot
HOT
N/O
120 - 277 Volts AC
0-10VDC
Dimming Ballast
Line Voltage
Inputs to
Ballast
Fixture Sensor Power Pack
120-277VAC, 60Hz
@120VAC 5A (N/0)
3A (N/C)
@277VAC 4.3A (N/0)
2.5A (N/C)
C
US
LISTED
88T9
Appliance
Control
Ground
GROUND
Neutral
NEUTRAL
Hot
HOT
120 - 277 Volts AC
Green Operation
LED
RJ45
Plug
from FS
sensor
FS-PP
Santa Clara, CA
800.879.8585
03500r1
N/C
12-18AWG
CU wire only
US
LISTED
Strip Gauge
C
OUTPUTS
TO LOAD
Fixture Sensor Power Pack
120-277VAC, 60Hz
@120VAC 5A (N/0)
3A (N/C)
@277VAC 4.3A (N/0)
2.5A (N/C)
Neutral
Lighting
Load
Outputs
to Lamps
RJ45
Plug
from FS
sensor
Green Operation
LED
FS Low Voltage w/ FS-CK-1 Cable Kit
S E N S O R S
FS-PP
Santa Clara, CA
800.879.8585
03500r1
N/C
RJ45
TO SENSOR
N/O
OUTPUTS
TO LOAD
COM
N/C
Grey
ISOLATED RELAY
Com
Violet
RJ45
TO SENSOR
0-10VDC
120-277VAC Input
FS Power Pack - Standard On/Off
12-18AWG
CU wire only
FS Power Pack - Dimming
Strip Gauge
• Connections:
Low Voltage: RJ45 to FS Sensors
Line & Load: 12-18 AWG Screw Terminal
• 32°-131°F (0°-55° C)
• Dimensions: 7.5” x .87” x 1” (190.5mm x
22.1mm x 25.4mm)
120-277VAC Input
120/277 VAC, 60Hz
Form C with Zero Crossing on N/O Relay
Output: 70mA @ 24VDC
Load Reg @120: 600W N/O, 360W N/C ballast,
1/6 hp
• Load Reg @277: 1200W N/O, 700W N/C ballast
ISOLATED RELAY
Wiring &
Cable
Connectors
•
•
•
•
F I X T U R E
Specifications
Two FS sensors connected to two FS-PP
FS-PP
FS-PP
FS sensor
FS sensor
two FS-CK-1 kits required
(one cable unused)
Cable Connectors
10' (3m)
FS-C1: One 10’ cable with a shielded
RJ45 male connector at each end.
6" (152mm)
FS-C2: One 6’ cable with 3 flying
leads at one end and a shielded RJ45
male connector at the other.
3' (914mm)
FS-C3: One 3’ cable with a shielded 90º
RJ45 male connector at one end and a
shielded straight male RJ45 connector
at the other end, for space-limited
applications.
Ordering
Information
Pub. No. 26901
Catalog No.
FS-C4: Shielded RJ45
splitter with female to
dual female receptacles.
FS-C5: Shielded
RJ45 male to male
coupler.
Description
FS-PP
Fixture Power Pack 120/277 VAC; 60Hz
FS-CK2
6’ cable with 3 flying leads at one end and a shielded FJ45 male connector at the other, plus a shielded male to
male coupler
FS-C1
10’ cable with shielded RJ45 male connectors at each end
FS-C2
6’ cable with 3 flying leads at one end and a shielded RJ45 male connector on the other
FS-C3
3’ cable with shielded 90º male RJ45 on one end and a shielded straight male RJ45 at the other
FS-C4
Shielded RJ45 splitter with female to dual female receptacles
FS-C5
Shielded RJ45 male to male coupler
www.wattstopper.com
800.879.8585
11
Watt Stopper/Legrand Resources & Tools
CAD Resource Center
Over 300 CAD drawings from which to choose
Wiring diagrams you can place in your own CAD drawings
Available at www.wattstopper.com
Support & Services
Commission and start-up services
District managers, trained representatives and experts
available to answer all technical questions
Continuing Education
Courses throughout North America qualify for AIA/CES
Health, Safety and Welfare (HSW) credit and NCQLP
Lighting Education Units (LEUs)
In-person and on-line events
Course selection available at www.wattstopper.com
Product Selection Guide
Compilation of product ordering information, cut sheets,
design and application assistance
Corporate Headquarters
2800 De La Cruz Blvd.
Santa Clara, CA 95050
Tech Support: 800.879.8585
866.588.5473
www.wattstopper.com
WS-07-20086
Download