WATER SOURCE / GEOTHERMAL HEAT PUMPS AND AIR CONDITIONERS Water Source / Geothermal Heat Pumps & Air Conditioners WHISPERLINE VERTICAL STACK TM u Classic Heat Pump / Air Conditioner u Single Riser Heat Pump / Air Conditioner WHISPERLINE DUCTED VERTICAL TM u Classic Heat Pump / Air Conditioner with Slide-out Chassis u Single Riser Heat Pump / Air Conditioner with Slide-out Chassis u Water-Source Heat Pump / Air Conditioner with Fixed Chassis WHISPERLINE HORIZONTAL TM u Heat Pump / Air Conditioner with Slide-out Chassis WHISPERPACK VERTICAL STACK TM u Air Conditioner with Hydronic Heating WHISPERPACK DUCTED VERTICAL TM u Air Conditioner with Hydronic Heating and Slide-out Chassis … From the pioneer in vertical stack HVAC technology and innovation. P. O. Box 1390 • Easton, MD 21601 USA Tel. (410) 822-9200 • www.whalencompany.com Thank you for your interest in The Whalen Company. This catalog includes basic information on our comprehensive line of commercial air handlers and fan coil products. Additional data is available at www.whalencompany.com where you can download the most current product specifications. You may also contact us at 410-822-9200 or sales@whalencompany.com. PRODUCT DESCRIPTION KEY WSHP - Water Source Heat Pump GHP - Geothermal Heat Pump WSAC - Water Source Air Conditioner WLHP - Water Loop Heat Pump PAGE WHISPERLINE SERIES TM Classic WSHP/GHP/WSAC applications Vertical stack with slide-out chassis ½ to 3 Tons 200 to 1200 Cfm 3 Single Riser System with integral pump WSHP/GHP/WSAC applications Vertical stack with slide-out chassis ½ to 3 Tons 200 to 1200 Cfm 4 Ducted Vertical Products Classic WSHP/GHP/WSAC applications Ducted vertical with slide-out chassis ½ to 3 Tons 200 to 1200 Cfm 5 Single Riser System with integral pump WSHP/GHP/WSAC applications Ducted vertical with slide-out chassis ½ to 3 Tons 200 to 1200 Cfm 6 WWSVX Water Source Heat Pump WLHP applications Ducted vertical with fixed chassis 1 ½ to 5 Tons 7 Horizontal Products WWSHX Water Source Heat Pump WLHP applications Ducted horizontal unit ¾ to 5 Tons 8 WHISPERPACK SERIES TM Vertical Stack Products Whisperpack Water Source AC with Hydronic Heating WSHP/WSAC applications Vertical Stack with slide-out chassis ½ to 3 Tons 200 to 1200 Cfm TM 9 Ducted Vertical Products Whisperpack Water Source AC with Hydronic Heating WSHP/WSAC applications Ducted vertical with slide-out chassis ½ to 3 Tons 200 to 1200 Cfm TM 10 -2WHALEN CO. - P.O. Box 1390 - Easton, Maryland 21601 - Tel. (410) 822-9200 - Fax (410) 822-8926 - www.whalencompany.com Whisperline Vertical Stack TM Classic Water Source/Geothermal Heat Pump and Air Conditioner A proven time and money saving concept in air conditioning any type of building... advantageous for both new construction and the renovation of apartments, condominiums, hotels, senior living facilities, dormitories and office buildings. Features: • • • • • • Tons ½ ¾ 1 Tons 1¼ ½ 1½ ¾ 2 1 2½ 1¼ 3 1½ 2 2½ 3 Flexible configuration Efficient operation Low installed cost Reduced maintenance costs Small footprint Clean and quiet operation Vertical Stack Whisperline Classic Classic Vertical Stack Whisperline TM Model 3.2 3.2 3.2 Risers A - Water Source and Geothermal Heat Pump VI-A-403 S A1 - Water Source Heat Pump with Electric Heat (Boilerless Design) VI-A-503 D A2 - Water Source/Geothermal Heat Pump with Electric Heat (Supplemental) ¾ VI-A-603 S B - Water Source Air Conditioning Unit with Electric Heat VI-A-803 D D - Water Source Air Conditioning Unit VI-A-1003 D VI-A-1203 D Model Tons ½ VI-A-303 S VI-A-203 S COP Applications VI-A-203 S Standard 1 Master 1¼ Slave 1½ Special 2 2½ AHRI Certified - ASHRAE/ANSI/AHRI/ISO Standard 13256-1 CFM 280 GPM 1.5 Model S VI-A-303 CFM 340 GPM 2.5 VI-A-403 S 420 3.3 3 Water Loop Heat Pump Ground Loop Heat Pump Cooling 86°F Heating 68°F Cooling 77°F Heating 32°F Capacity Btuh EER Btuh / W AHRI Capacity Btuh- ASHRAE/ANSI/AHRI/ISO COP Capacity Btuh EER Btuh / W Capacity Btuh COP Certified Standard 13256-1 6,500 13.0 8,300 5.1 6,900 14.2Loop CFM 5,200GPM 3.2 Model Water Loop Heat Pump Ground Heat Pump 9,300 13.8 Cooling 86°F 11,800 13.8 Capacity Btuh EER Btuh / W VI-A-503 D 540 3.9 14,600 VI-A-203 S 280 1.5 6,500 VI-A-603 S 630 4.5 18,000 VI-A-303 S 340 2.5 9,300 VI-A-803 D 830 6.0 23,000 VI-A-403 S 420 3.3 11,800 VI-A-1003 D 970 7.5 29,200 VI-A-503 D 540 3.9 14,600 VI-A-1203 D 1170 9.0 33,100 VI-A-603 S 630 4.5 18,000 Cooling based upon 80.6°F DB, 66.2°F WB entering air temperature VI-A-803 D 830 6.0 23,000 16.7 13.0 14.5 13.8 13.1 13.8 14.2 16.7 14.2 14.5 12,000 5.2 18,400 8,300 21,700 12,000 30,000 14,900 35,900 18,400 42,000 21,700 6.0 5.1 5.0 5.2 5.0 5.0 5.0 6.0 5.2 5.0 30,000 5.0 Heating 68°F 14,900 5.0 Capacity Btuh COP 13.1 Water L Cooling 86°F Cooling 77°F Heating 32°FCapacity Btuh EER Btu 12,500 15.8 9,600 3.2 Capacity Btuh EER Btuh COP6,500 VI-A-203 S / W 280Capacity Btuh 1.5 13.0 9,650 15,200 6,900 18,800 9,650 25,000 12,500 29,700 15,200 33,600 18,800 25,000 3.5 VI-A-1003 D 970 7.5 29,200 14.2 35,900 5.0 29,700 3.2 VI-A-1203 D 1170 9.0 33,100 14.2 42,000 5.2 33,600 3.2 3.2 3.3 Cooling based upon 80.6°F DB, 66.2°F WB entering air temperature Heating based upon 68°F DB, 59°F WB entering air temperature 14.8 17.7 14.2 VI-A-303 S 15.5 14.8 VI-A-403 S 14.5 15.8 VI-A-503 D 15.5 17.7 VI-A-603 S 15.3 15.5 VI-A-803 D 14.5D VI-A-1003 340 420 540 630 830 970 7,160 3.2 11,000 5,200 13,000 2.5 7,160 19,000 3.3 9,600 22,000 3.9 11,000 25,400 4.5 13,000 6.0 19,000 7.5 3.5 3.2 9,300 3.2 3.2 11,800 3.2 3.2 14,600 3.2 3.5 3.3 18,000 3.2 23,000 3.2 29,200 15.5D 22,000 9.0 3.2 33,100 VI-A-1203 1170 25,400 3.3air temperature Cooling 15.3 based upon 80.6°F DB, 66.2°F WB entering 13.8 13.8 16.7 14.5 13.1 14.2 14.2 Mode VI-A-203 Performance based upon 208/60/1 voltage Mode VI-A-303 Heating based upon 68°F DB, 59°F WB entering air temperature R-410A Refrigerant Performance based upon 208/60/1 voltage Model Compressor Charge (oz.) Fan Motor Voltage Estimated Ship Weight Cabinet / Chassis (lbs) Heating based upon 68°F DB, 59°F WB entering air temperature Performance based upon 208/60/1 voltage 145 / 85 VI-A-403 VI-A-503 VI-A-203 VI-A-603 VI-A-303 VI-A-803 VI-A-403 VI-A-100 VI-A-503 VI-A-120 VI-A-603 VI-A-203 S Rotary 23.5 PSC, EC VI-A-303 S Rotary 26 PSC, EC 145 / 87 VI-A-403 S Rotary 25.25 PSC, EC 145 / 89 VI-A-803 VI-A-503 D Rotary 33.5 PSC, EC 208-230/60/1 165 / 128 VI-A-100 VI-A-603 S Rotary 35 PSC, EC 265/60/1 165 / 129 VI-A-120 VI-A-803 D Rotary 38 EC VI-A-1003 D Scroll 48.5 EC 185 / 171 VI-A-1203 D Scroll 54 EC 185 / 181 165 / 138 -3WHALEN CO. - P.O. Box 1390 - Easton, Maryland 21601 - Tel. (410) 822-9200 - Fax (410) 822-8926 - www.whalencompany.com Whisperline Vertical Stack TM Single Riser System with Integral Pump Water Source/Geothermal Heat Pump and Air Conditioner By using only one riser to distribute fluid to a heat pump when two pipes are usually required, allows designers to specify a single riser size to help control costs during initial and payout phases of construction. Features: • • • • • • Tons ½ ¾ 1 Tons 1¼ ½ 1½ ¾ 2 1 2½ 1¼ 3 1½ 2 2½ 3 Superior comfort Efficient, clean and quiet operation Robust, energy-saving “green” design Small footprint ... flexible configurations Reduced project design requirements Lower installation cost ... lower O&M costs Vertical Stack Whisperline Single Riser System (SRS)Pump with Integral Pump Vertical Stack Whisperline Single Riser System (SRS) with Integral TM Model Applications A - Water Source and Geothermal Heat Pump VI-A-403 S A1 - Water Source Heat Pump with Electric Heat (Boilerless Design) VI-A-503 D A2 - Water Source/Geothermal Heat Pump with Electric Heat (Supplemental) VI-A-603 S B - Water Source Air Conditioning Unit with Electric Heat D - Water Source Air Conditioning Unit Model CFM 3.2 3.2 3.5 3.2 280 Cooling 86°F 1.5 CFM 340 GPM 2.5 VI-A-403 S 420 3.3 1 Master 1¼ Slave 1½ Special 2 Water Loop Heat Pump GPM Model S VI-A-303 Standard AHRI Certified - ASHRAE/ANSI/AHRI/ISO Standard 13256-1 2½ VI-A-1003 D VI-A-203 S 3.2 ¾ VI-A-803 D VI-A-1203 D Tons ½ VI-A-303 S Capacity Btuh COP Risers VI-A-203 S 6,500 EER Btuh / W VI-A-503 D 540 3.9 14,600 VI-A-203 S 280 1.5 6,500 VI-A-603 S 630 4.5 18,000 VI-A-303 S 340 2.5 9,300 VI-A-803 D 830 6.0 23,000 VI-A-403 S 420 3.3 11,800 VI-A-1003 D 970 7.5 29,200 VI-A-503 D 540 3.9 14,600 VI-A-1203 D 1170 9.0 33,100 VI-A-603 S 630 4.5 18,000 Cooling based upon 80.6°F DB, 66.2°F WB entering air temperature VI-A-803 D 830 6.0 23,000 16.7 13.0 14.5 13.8 13.1 13.8 14.2 16.7 14.2 14.5 Cooling 77°F Capacity Btuh- ASHRAE/ANSI/AHRI/ISO COP Capacity Btuh EER Btuh / W AHRI Certified Standard 13256-1 13.0 8,300 Water Loop Heat Pump 9,300 Cooling 86°F 13.8 11,800 13.8 Capacity Btuh EER Btuh / W Ground Loop Heat Pump 3 Heating 68°F 5.1 12,000 Heating 68°F 5.2 14,900 5.0 Capacity Btuh COP COP Water 14.2Loop Heat Pump 5,200 3.2 Ground Model CFM GPM Cooling 86°F 9,650 Cooling 77°F 14.8 7,160 3.2 Heating 32°F 12,500 15.8 9,600 3.2 Capacity Btuh EER Btu Capacity Btuh EER Btuh / W Capacity Btuh COP 6,900 18,400 8,300 21,700 12,000 30,000 14,900 35,900 18,400 42,000 21,700 6.0 5.1 5.0 5.2 5.0 5.0 5.0 6.0 5.2 5.0 15,200 6,900 18,800 9,650 25,000 12,500 29,700 15,200 33,600 18,800 13.1 30,000 5.0 25,000 VI-A-1003 D 970 7.5 29,200 14.2 35,900 5.0 29,700 VI-A-1203 D 1170 9.0 33,100 14.2 42,000 5.2 33,600 3.2 Cooling based upon 80.6°F DB, 66.2°F WB entering air temperature 3.2 Heating based upon 68°F DB, 59°F WB entering air temperature 3.3 Performance based upon 208/60/1 voltage 17.7 11,000 1.5 3.5 6,500 VI-A-203 S 280 14.2 5,200 3.2 15.5 13,000 2.5 3.2 9,300 VI-A-303 S 340 14.8 7,160 3.2 14.5 19,000 3.3 3.211,800 VI-A-403 S 420 15.8 9,600 3.2 15.5 22,000 3.9 3.214,600 VI-A-503 D 540 17.7 11,000 3.5 15.3 25,400 4.5 3.318,000 VI-A-603 S 630 15.5 13,000 3.2 VI-A-803 D 830 6.0 23,000 14.5 19,000 3.2 VI-A-1003 D 970 7.5 29,200 15.5 22,000 3.2 VI-A-1203 D 1170 9.0 33,100 15.3 25,400 3.3 Cooling based upon 80.6°F DB, 66.2°F WB entering air temperature 13. 13. 13. 16. 14. 13. 14. 14. Mode VI-A-20 Mode VI-A-30 Heating based upon 68°F DB, 59°F WB entering temperature R-410AairRefrigerant Performance upon 208/60/1 voltage Model basedCompressor Heating 32°F Capacity Btuh Charge (oz.) Fan Motor Voltage Estimated Ship Weight Cabinet / Chassis (lbs) Heating based upon 68°F DB, 59°F WB entering air temperature Performance based upon 208/60/1 voltage 145 / 85 VI-A-40 VI-A-50 VI-A-20 VI-A-60 VI-A-30 VI-A-80 VI-A-40 VI-A-100 VI-A-50 VI-A-120 VI-A-60 VI-A-203 S Rotary 23.5 PSC, EC VI-A-303 S Rotary 26 PSC, EC 145 / 87 VI-A-403 S Rotary 25.25 PSC, EC 145 / 89 VI-A-80 VI-A-503 D Rotary 33.5 PSC, EC 208-230/60/1 165 / 128 VI-A-100 VI-A-603 S Rotary 35 PSC, EC 265/60/1 165 / 129 VI-A-120 VI-A-803 D Rotary 38 EC VI-A-1003 D Scroll 48.5 EC 185 / 171 VI-A-1203 D Scroll 54 EC 185 / 181 165 / 138 -4WHALEN CO. - P.O. Box 1390 - Easton, Maryland 21601 - Tel. (410) 822-9200 - Fax (410) 822-8926 - www.whalencompany.com Whisperline Ducted Vertical with Slide-out Chassis TM Classic Water Source/Geothermal Heat Pump and Air Conditioner A vertical unit requiring access on only one side and serviceability that provides added flexibility over traditional units. Used in a variety of new and renovation construction projects similar to apartments, dormitories and office buildings. Only one side access required with slide-out chassis. Features: • • • • • Flexible configurations Efficient operation Reduced maintenance costs Small footprint Clean and quiet operation Tons ½ ¾ 1 Tons 1¼ ½ 1½ ¾ 2 1 2½ 1¼ 3 1½ Closetline CLASSICDucted Classic Whisperline TM Model Applications Risers VI-A-203 S ½ VI-A-303 S A - Water Source and Geothermal Heat Pump VI-A-403 S A1 - Water Source Heat Pump with Electric Heat (Boilerless Design) VI-A-503 D A2 - Water Source/Geothermal Heat Pump with Electric Heat (Supplemental) ¾ VI-A-603 S B - Water Source Air Conditioning Unit with Electric Heat 2 VI-A-803 D D - Water Source Air Conditioning Unit 2½ VI-A-1003 D 3 VI-A-1203 Model D CFM COP 3.2 3.2 3.2 3.5 3.2 3.2 3.2 3.3 280 Model S VI-A-303 CFM 340 GPM 2.5 VI-A-403 S 420 3.3 1 Master 1¼ Slave 1½ 2 AHRI Certified - ASHRAE/ANSI/AHRI/ISO Standard 13256-1 2½ Water Loop Heat Pump GPM 1.5 Standard Special Cooling 86°F CapacityBtuh VI-A-203 S Tons EER Btuh / W 6,500 Cooling 77°F Capacity Btuh- ASHRAE/ANSI/AHRI/ISO COP Capacity Btuh EER Btuh / W AHRI Certified Standard 13256-1 13.0 8,300 5.1 Water Loop Heat Pump 9,300 12,000 Cooling 86°F 13.8 Heating 68°F 5.2 11,800 13.8 14,900 5.0 CapacityBtuh EER Btuh / W Capacity Btuh COP VI-A-503 D 540 3.9 14,600 VI-A-203 S 280 1.5 6,500 VI-A-603 S 630 4.5 18,000 VI-A-303 S 340 2.5 9,300 VI-A-803 D 830 6.0 23,000 VI-A-403 S 420 3.3 11,800 VI-A-1003 D 970 7.5 29,200 VI-A-503 D 540 3.9 14,600 VI-A-1203 D 1170 9.0 33,100 VI-A-603 S 630 4.5 18,000 Cooling based upon 80.6°F DB, 66.2°F WB entering air temperature VI-A-803 D 830 6.0 23,000 Ground Loop Heat Pump 3 Heating 68°F 16.7 13.0 14.5 13.8 13.1 13.8 14.2 16.7 14.2 14.5 18,400 8,300 21,700 12,000 30,000 14,900 35,900 18,400 42,000 21,700 6.0 5.1 5.0 5.2 5.0 5.0 5.0 6.0 5.2 5.0 13.1 30,000 COP 6,900 14.2Loop Heat Pump 5,200 3.2 Water Ground Model CFM 9,650 7,160GPM Cooling 86°F Cooling 77°F 14.8 Heating 32°F 3.2 12,500 15.8 9,600 3.2 CapacityBtuh EER Btu Capacity Btuh EER Btuh / W Capacity Btuh COP 15,200 6,900 18,800 9,650 25,000 12,500 29,700 15,200 33,600 18,800 17.7 VI-A-203 S 14.2 15.5 VI-A-303 S 14.8 14.5 VI-A-403 S 15.8 15.5 VI-A-503 D 17.7 15.3 VI-A-603 S 15.5 5.0 25,000 VI-A-1003 D 970 7.5 29,200 14.2 35,900 5.0 29,700 VI-A-1203 D 1170 9.0 33,100 14.2 42,000 5.2 33,600 Cooling based upon 80.6°F DB, 66.2°F WB entering air temperature Heating 32°F Capacity Btuh 630 11,000 5,200 1.5 13,000 7,160 2.5 19,000 9,600 3.3 22,000 11,000 3.9 25,400 13,000 4.5 3.5 3.2 6,500 3.2 3.2 9,300 3.2 3.2 11,800 3.2 3.5 14,600 3.3 3.2 18,000 VI-A-803 D 14.5 830 19,000 6.0 3.2 23,000 13. VI-A-1003 15.5D 970 22,000 7.5 3.2 29,200 14. 280 340 420 540 VI-A-1203 1170 15.3D 25,400 9.0 3.3 33,100 Cooling based upon 80.6°F DB, 66.2°F WB entering air temperature 13. 13. 13. 16. 14. 14. Mode Heating based upon 68°F DB, 59°F WB entering air temperature VI-A-20 Performance based upon 208/60/1 voltage R-410AairRefrigerant Heating based upon 68°F DB, 59°F WB entering temperature Model based Compressor Performance upon 208/60/1 voltage Charge (oz.) Fan Motor Voltage Estimated Ship Weight Cabinet / Chassis (lbs) VI-A-203 S Rotary 23.5 PSC, EC VI-A-303 S Rotary 26 PSC, EC 145 / 87 VI-A-403 S Rotary 25.25 PSC, EC 145 / 89 VI-A-503 D Rotary 33.5 PSC, EC 208-230/60/1 165 / 128 VI-A-603 S Rotary 35 PSC, EC 265/60/1 165 / 129 Mode VI-A-30 Heating based upon 68°F DB, 59°F WB entering air temperature Performance based upon 208/60/1 voltage 145 / 85 VI-A-803 D Rotary 38 EC 165 / 138 VI-A-1003 D Scroll 48.5 EC 185 / 171 VI-A-1203 D Scroll 54 EC 185 / 181 -5WHALEN CO. - P.O. Box 1390 - Easton, Maryland 21601 - Tel. (410) 822-9200 - Fax (410) 822-8926 - www.whalencompany.com VI-A-40 VI-A-503 VI-A-203 VI-A-60 VI-A-303 VI-A-803 VI-A-403 VI-A-100 VI-A-503 VI-A-120 VI-A-603 VI-A-803 VI-A-100 VI-A-120 Whisperline Ducted Vertical with Slide-out Chassis TM Single Riser System with Integral Pump Water Source/Geothermal Heat Pump and Air Conditioner By using only one riser to distribute fluid to a heat pump when two pipes are usually required, this unit allows designers to specify a single riser size to help control costs during initial and payout phases of construction. Only one side access required with slide-out chassis. Features: • • • • • Tons ½ ¾ 1 Tons 1¼ ½ 1½ ¾ 2 1 2¼ ½ 1 1 3½ 2 2½ 3 Efficient, clean and quiet operation Robust, energy-saving “green” design Small footprint ... flexible configurations Reduced project design requirements Lower installation cost ... lower O&M costs Whisperline Single Riser (SRS) with Integral Pump Closetline Single Ducted Riser System (SRS) with System Integral Pump TM Model VI-A-403 S A1 - Water Source Heat Pump with Electric Heat (Boilerless Design) VI-A-503 D A2 - Water Source/Geothermal Heat Pump with Electric Heat (Supplemental) VI-A-603 S B - Water Source Air Conditioning Unit with Electric Heat D - Water Source Air Conditioning Unit Model 3.2 CFM GPM 280 1.5 CFM GPM 340 2.5 VI-A-403 S 420 3.3 VI-A-503 S D VI-A-203 VI-A-603 S S VI-A-303 540 280 630 340 3.9 1.5 4.5 2.5 VI-A-803 S D VI-A-403 VI-A-1003 VI-A-503 DD VI-A-1203 VI-A-603 SD 830 420 970 540 1170 630 Standard 1 Master 1¼ Slave 1½ Special 2 2 ½ Standard 13256-1 AHRI Certified - ASHRAE/ANSI/AHRI/ISO 3 Water Loop Heat Pump Ground Loop Heat Pump VI-A-1003 D Model 3.2 ¾ VI-A-803 D VI-A-1203 D Tons ½ A - Water Source and Geothermal Heat Pump VI-A-203 S 3.2 Risers VI-A-303 S VI-A-303 S COP Applications VI-A-203 S Cooling 86°F Heating 68°F Cooling 77°F Heating 32°F Certified Standard 13256-1 Capacity Btuh EER Btuh / W AHRI Capacity Btuh- ASHRAE/ANSI/AHRI/ISO COP Capacity Btuh EER Btuh / W Capacity Btuh COP Wate 6,500 13.0 8,300 5.1 6,900 14.2 5,200 GPM 3.2 Water Loop Heat Pump Ground Loop Heat Pump Model CFM Cooling 86°F 9,300 Cooling 86°F 13.8 12,000 9,650 Cooling 77°F 14.8 7,160 Heating 68°F 5.2 Heating 32°F 3.2 Capacity Btuh EER B 11,800Btuh 13.8 / W 14,900Btuh 5.0 12,500Btuh 15.8 / W 9,600 Btuh 3.2 Capacity EER Btuh Capacity COP Capacity EER Btuh Capacity COP 6.0 3.3 7.5 3.9 9.0 4.5 14,600 6,500 18,000 9,300 23,000 11,800 29,200 14,600 33,100 18,000 Cooling based 80.6°F DB, 6.0 66.2°F WB entering air temperature VI-A-803 D upon830 23,000 16.7 13.0 14.5 13.8 13.1 13.8 18,400 8,300 21,700 12,000 30,000 14,900 6.0 5.1 5.0 5.2 5.0 5.0 15,200 6,900 18,800 9,650 14.2 16.7 14.2 14.5 35,900 18,400 42,000 21,700 5.0 6.0 5.2 5.0 25,000 12,500 29,700 15,200 33,600 18,800 13.1 30,000 5.0 25,000 3.5 VI-A-1003 D 970 7.5 29,200 14.2 35,900 5.0 29,700 3.2 VI-A-1203 D 1170 9.0 33,100 14.2 42,000 5.2 33,600 3.2 Cooling based upon 80.6°F DB, 66.2°F WB entering air temperature 3.2 Heating based upon 68°F DB, 59°F WB entering air temperature 3.3 17.7 VI-A-203 S 14.2 15.5 VI-A-303 S 14.8 14.5 VI-A-403 S 15.8 15.5 VI-A-503 D 17.7 15.3 VI-A-603 S 15.5 VI-A-803 D 14.5 VI-A-1003 D 15.5 280 11,000 5,200 1.5 340 13,000 7,160 2.5 420 19,000 9,600 3.3 540 22,000 11,000 3.9 25,400 4.5 630 13,000 830 19,000 6.0 3.5 6,500 3.2 3.2 9,300 3.2 3.2 11,800 3.2 3.2 14,600 3.5 3.3 18,000 3.2 3.2 23,000 3.2 29,200 13 16 14 13 970 22,000 7.5 14 VI-A-1203 D 117025,400 9.0 14 15.3 3.3 33,100 Mod Cooling based upon 80.6°F DB, 66.2°F WB entering air temperature VI-A-2 Performance based upon 208/60/1 voltage Mod VI-A-3 Heating based upon 68°F DB, 59°F WB entering temperature R-410AairRefrigerant Performance upon 208/60/1 voltage Model based Compressor 13 13 Charge (oz.) Fan Motor 23.5 PSC, EC Voltage Estimated Ship Weight Cabinet / Chassis (lbs) Heating based upon 68°F DB, 59°F WB entering air temperature VI-A-4 Performance based upon 208/60/1 voltage VI-A-5 VI-A-2 VI-A-6 VI-A-3 145 / 85 VI-A-8 VI-A-4 VI-A-10 VI-A-5 VI-A-12 VI-A-6 VI-A-203 S Rotary VI-A-303 S Rotary 26 PSC, EC 145 / 87 VI-A-403 S Rotary 25.25 PSC, EC 145 / 89 VI-A-8 VI-A-503 D Rotary 33.5 PSC, EC 208-230/60/1 165 / 128 VI-A-10 VI-A-603 S Rotary 35 PSC, EC 265/60/1 165 / 129 VI-A-12 VI-A-803 D Rotary 38 EC VI-A-1003 D Scroll 48.5 EC 185 / 171 VI-A-1203 D Scroll 54 EC 185 / 181 165 / 138 -6WHALEN CO. - P.O. Box 1390 - Easton, Maryland 21601 - Tel. (410) 822-9200 - Fax (410) 822-8926 - www.whalencompany.com Whisperline Ducted Vertical with Fixed Chassis TM WWSVC/WWSVX Water Source Heat Pump and A/C 1-1/2 thru 5 Tons Available with energy saving ECM motor Features: • 100% Factory run tested. • All units operate with environmentally friendly R-410 refrigerant. • Heavy Gauge Galvanized Steel Cabinet. • Cabinets insulated with ¾” Tuf-Skin RX™ treated with an anti-microbial agent. • Non-corrosive Thermoplastic Condensate Pan, sloped for positive drainage. • High and Low pressure Service Ports. • Refrigerant Filter-drier and Discharge Muffler. • Coaxial water-to-refrigerant heat exchanger. • Heat exchanger available in Copper or CuproNickel. • Digital Control Module (DCM). • Reversable Blower. • Multi-speed blower motor. • Panel-mounted FPT Water Connections. • High efficiency rotary or scroll compressor. • System reversing valve (4-way). • Large Removable Panels for Service access. • 50 VA Transformer. • 1” Throwaway Filter. • 208/230/1PH ASHRAE/ANSI/AHRI/ISO Standard 13256-1 Water Loop Heat Pump Cooling 86°F Heating 68°F Capacity EER Capacity COP Btuh Btuh / W Btuh Model CFM GPM WWSVC009 300 3.0 8,000 13.0 11,200 4.2 WWSVC012 340 3.5 11,000 13.0 14,000 4.2 WWSVC018 550 6.1 17,400 13.0 22,700 4.2 WWSVC024 380 6.6 23,000 13.0 30,500 4.2 WWSVC030 930 8.8 27,600 13.0 36,400 4.2 WWSVC036 970 10.5 33,400 13.0 45,000 4.2 WWSVC042 1250 11.6 39,000 13.0 50,000 4.2 WWSVC048 1400 14.0 46,800 13.0 58,100 4.2 WWSVC060 1760 15.5 59,000 13.0 68,100 4.2 Model CFM GPM ASHRAE/ANSI/AHRI/ISO Standard 13256-1 Water Loop Heat Pump Cooling 86°F Heating 68°F Capacity EER Capacity COP Btuh Btuh / W Btuh WWSVX018 550 5.0 17,000 14.0 21,000 4.3 WWSVX024 380 6.1 23,400 14.2 28,000 4.3 WWSVX030 930 9.0 28,000 14.0 32,800 4.3 WWSVX036 970 10.0 33,000 14.0 42,100 4.3 WWSVX042 1250 10.5 40,500 14.0 47,500 4.4 WWSVX048 1400 12.5 47,100 14.0 53,800 4.3 WWSVX060 1760 15.5 56,000 14.0 69,300 4.3 Model Width Depth Height WWSVC009 21.5 21.5 28.25 WWSVC012 21.5 21.5 28.25 WWSVC018 21.5 21.5 36.25 WWSVC024 21.5 21.5 36.25 WWSVC030 21.5 21.5 39.25 WWSVC036 21.5 21.5 39.25 WWSVC042 21.5 26.0 43.25 WWSVC048 26.0 26.0 43.25 WWSVC060 26.0 26.0 43.25 -7WHALEN CO. - P.O. Box 1390 - Easton, Maryland 21601 - Tel. (410) 822-9200 - Fax (410) 822-8926 - www.whalencompany.com Whisperline Horizontal TM WWSHC/WWSHX Horizontal Water Source Heat Pump and A/C 3/4 thru 5 Tons Available with energy saving ECM motor Features: • 100% Factory run tested. • All units operate with environmentally friendly R-410 refrigerant. • Heavy Gauge Galvanized Steel Cabinet. • Cabinets insulated with ¾” Tuf-Skin RX™ treated with an anti-microbial agent. • Non-corrosive Thermoplastic Condensate Pan, sloped for positive drainage. • High and Low pressure Service Ports. • Refrigerant Filter-drier and Discharge Muffler. • Coaxial water-to-refrigerant heat exchanger. • Heat exchanger available in Copper or CuproNickel. • Digital Control Module (DCM). • Multi-speed blower motor. • Panel-mounted FPT Water Connections. • High efficiency rotary or scroll compressor. • System reversing valve (4-way). • Large Removable Panels for Service access. • 50 VA Transformer. • 1” Throwaway Filter. • 208/230/1PH • Other voltages available contact factory. ASHRAE/ANSI/AHRI/ISO Standard 13256-1 Water Loop Heat Pump Cooling 86°F Heating 68°F Capacity EER Capacity COP Btuh Btuh / W Btuh Model CFM GPM WWSHC009 300 3.0 8,000 13.0 11,200 4.2 WWSHC012 340 3.5 11,000 13.0 14,000 4.2 WWSHC018 550 6.1 17,400 13.0 22,700 4.2 WWSHC024 380 6.6 23,000 13.0 30,500 4.2 WWSHC030 930 8.8 27,600 13.0 36,400 4.2 WWSHC036 970 10.5 33,400 13.0 45,000 4.2 WWSHC042 1250 11.6 39,000 13.0 50,000 4.2 WWSHC048 1400 14.0 46,800 13.0 58,100 4.2 WWSHC060 1760 15.5 59,000 13.0 68,100 4.2 ASHRAE/ANSI/AHRI/ISO Standard 13256-1 Water Loop Heat Pump Cooling 86°F Heating 68°F Capacity EER Capacity COP Btuh Btuh / W Btuh Model CFM GPM WWSHX018 550 6.1 17,000 14.0 22,000 4.3 WWSHX024 380 6.6 23,200 14.0 30,500 4.4 WWSHX030 930 8.8 27,800 14.0 36,200 4.4 WWSHX036 970 10.5 33,500 14.0 44,600 4.5 WWSHX042 1250 11.6 39,500 14.0 49,200 4.4 WWSHX048 1400 14.0 47,200 14.0 58,100 4.4 WWSHX060 1760 15.5 60,500 14.0 63,500 4.4 Model Length Width Height WWSHC009 19.13 34.13 17.00 WWSHC012 19.13 34.13 17.00 WWSHC018 20.13 43.13 17.00 WWSHC024 20.13 43.13 18.25 WWSHC030 20.13 43.13 18.25 WWSHC036 20.13 47.13 21.00 WWSHC042 20.13 47.13 21.00 WWSHC048 24.13 54.13 21.00 WWSHC060 24.13 54.13 21.00 -8WHALEN CO. - P.O. Box 1390 - Easton, Maryland 21601 - Tel. (410) 822-9200 - Fax (410) 822-8926 - www.whalencompany.com Whisperpack Vertical Stack TM Air Conditioning with Hydronic Heating Water Source Air Conditioning with Water Heating By packaging the best characteristics of our compressorized and fan coil product lines, we have developed a unit that offers the air conditioning performance we are known for with the operational characteristics found in our proven fan coil units. Features: • • • • • Flexible configurations Package design lowers field labor cost Incorporates energy sharing concepts Easy maintenance Clean and quiet operation dronic Heating dronic Heating TM dronic Heating Vertical StackWhisperpack Whisperpack Conditioning with Hydronic Heating Vertical Stack Air Air Conditioning with Hydronic Heating Model Applications Risers Tons Standard ½ ¾ 1 Master Slave 1¼ 1½ Special 2 VP-C-203 D VP-C-303 D VP-C-403 D VP-C-503 D VP-C-603 D VP-C-803 D VP-C-1003 D VP-C-1203 D Model Model VP-C-203 Model D C - Air Conditioning with Hydronic Heating AHRI Certified - ASHRAE/ANSI/AHRI/ISO Standard 13256-1 2½ Water Loop Heat Pump 3 Cooling 86°F CFM GPM AHRI Certified - ASHRAE/ANSI/AHRI/ISO Standard 13256-1 Capacity EER AHRI Certified - ASHRAE/ANSI/AHRI/ISO Standard 13256-1 Water Loop Heat Pump Btuh Loop Heat Btuh /W Water Pump Cooling 86°F 290 1.5 6400 Cooling 86°F 13.7 CFM GPM Capacity EER CFM GPM 345 2.5 9300 14.0 Capacity EER Btuh Btuh 465 3.3 11700 13.8/ W Btuh Btuh /W 290 1.5 6400 13.7 VP-C-303 D VP-C-403 D VP-C-203 VP-C-503 D D 540 3.9 14200 15.7 VP-C-203 D 290 1.5 6400 13.7 VP-C-303 345 2.5 9300 14.0 VP-C-603 D D 650 4.5 17800 14.6 VP-C-303 D 345 2.5 9300 14.0 VP-C-403 465 3.3 11700 13.8 VP-C-803 D D 865 6.0 22800 13.0 VP-C-403 D 465 3.3 11700 13.8 VP-C-503 DD 540 3.9 14200 15.7 VP-C-1003 1045 7.5 28200 13.5 VP-C-503 D 540 3.9 14200 15.7 VP-C-603 DD 650 4.5 17800 14.6 VP-C-1203 1100 9.0 32600 13.6 VP-C-603 D 650 4.5 17800 14.6 VP-C-803 D 865 6.0 22800 13.0 Cooling based upon 80.6°F DB, 66.2°F WB entering air temperature, 86.0 °F entering liquid temperature. VP-C-803 D 865 6.0 22800 13.0 VP-C-1003 D 1045 7.5 28200 13.5 VP-C-1003 D 1045 7.5 28200 13.5 VP-C-1203 D 1100 9.0 32600 13.6 VP-C-1203 D 1100 9.0 32600 13.6 Cooling based upon 80.6°F DB, 66.2°F WB entering air temperature, 86.0 °F entering liquid temperature. Cooling based upon 80.6°F DB, 66.2°F WB entering air temperature, 86.0 °F entering liquid temperature. Heating GPM Heating Heating 1.5 GPM Model GPM 2.5 3.3 1.5 3.9 1.5 D VP-C-203 2.5 4.5 2.5 D VP-C-303 3.3 6.0 3.3 D VP-C-403 3.9 7.5 3.9 D VP-C-503 4.5 9.0 4.5 VP-C-603 6.0 D 6.0 VP-C-803 7.5 D 7.5 D VP-C-1003 9.0 9.0 D VP-C-1203 Entering Liquid Temp Heating 105°F Capacity EER Entering Liquid Temp AHRI Certified - ASHRAE/ANSI/AHRI/ISO Standard Entering Liquid Temp Btuh Btuh /W Heating 105°F Water Loop He Heating 105°F 8000 270 Cooling Capacity EER CFM 8300 300 GPM Capacity EER Capacity Btuh Btuh / W 9600 360 Btuh Btuh /W Btuh 8000 270 14100 8000 290 8300 16800 8300 345 9600 21300 9600 465 14100 27800 14100 540 16800 31100 16800 650 21300 21300 865 27800 27800 1045 31100 31100 1100 475 270 300 600 300 360 800 360 475 950 475 600 1100 600 800 800 950 950 1100 1100 1.5 2.5 3.3 3.9 4.5 6.0 7.5 9.0 6400 9300 11700 14200 17800 22800 28200 32600 M Cooling based upon 80.6°F DB, 66.2°F WB entering air temperature, 86.0 °F entering liquid tem Heating based upon 2 row coil, 70°F DB entering air temperature, 105°F entering liquid temperature. Performance based upon 208/60/1 voltage Heating based upon 2 row coil, 70°F DB entering air temperature, 105°F entering liquid temperature. R-410A Heating based upon 2 row coil, 70°F DB entering air temperature, 105°FRefrigerant entering liquid temperature. Performance based upon 208/60/1 voltage Model based upon Compressor Charge Fan Motor Performance 208/60/1 voltage Voltage (oz.) VP-C-203 D VP-C-303 D VP-C-403 D VP-C-503 D VP-C-603 D VP-C-803 D VP-C-1003 D VP-C-1203 D Rotary Rotary Rotary Rotary Rotary Rotary Scroll Scroll 208-230/60/1 265/60/1 23 24 26.3 34 34 36 46 51 PSC, EC PSC, EC PSC, EC PSC, EC PSC, EC EC EC EC VP-C M M VP-C Estimated Ship VP-C Heating based upon 2 row coil, 70°F DB entering air temperature, 105°F entering liquid tempera VP-C Weight VP-C VP-C Performance based upon 208/60/1 voltage VP-C Cabinet / Chassis VP-C VP-C VP-C (lbs) VP-C VP-C VP-C 153 / 88 VP-C VP-C VP-C 153 / 90 VP-C VP-C VP-C 153 / 93 VP-C VP-C 173 / 135 VP-C VP-C 173 / 136 VP-C 173 / 148 192 / 183 192 / 194 -9WHALEN CO. - P.O. Box 1390 - Easton, Maryland 21601 - Tel. (410) 822-9200 - Fax (410) 822-8926 - www.whalencompany.com W Whisperpack Ducted Vertical with Slide-out Chassis TM Air Conditioning with Hydronic Heating Water Source Air Conditioning with Water Heating By packaging the best characteristics of our compressorized and fan coil product lines, we have developed a unit that offers the air conditioning performance we are known for with the operational characteristics found in our proven fan coil units. Only one side access required with slide-out chassis. Features: • • • • Package design lowers field labor cost Incorporates energy sharing concepts Easy maintenance Clean and quiet operation Closetpack Air Conditioning with Hydronic Heating Whisperpack Ducted Air Conditioning with Hydronic Heating TM Model VP-C-203 D VP-C-303 D VP-C-403 D VP-C-503 D VP-C-603 D VP-C-803 D VP-C-1003 D VP-C-1203 D Model Applications Risers Tons ½ ¾ Standard 1 C - Air Conditioning Master 1¼ with Hydronic Heating Slave 1½ Special 2 AHRI Certified - ASHRAE/ANSI/AHRI/ISO Standard 13256-1 2½ Water Loop 3 Heat Pump Cooling 86°F CFM GPM AHRI Certified - ASHRAE/ANSI/AHRI/ISO Standard 13256-1 Capacity Btuh EER Btuh / W Water Loop Heat Pump 290 1.5 6400Cooling 86°F13.7 CFM GPM 345 2.5 9300 14.0 Capacity 465 3.3 11700Btuh EER Btuh 13.8 / W Heating GPM Heating 1.5 Model GPM 2.5 Entering Liquid Temp Heating 105°F AHRI Certified - ASHRAE/ANSI/AHRI/ISO Standa Entering Capacity BtuhLiquid EERTemp Btuh / W Water Loop H Heating 105°F 8000 270 Cooling CFM GPM 8300 300 Capacity 9600 Btuh EER Btuh 360 / W Capacity Btuh E VP-C-203 Model D VP-C-303 D VP-C-403 D 3.3 VP-C-503 D 540 3.9 14200 15.7 3.9 14100 475 VP-C-203 D 290 1.5 6400 13.7 1.5 8000 270 1.5 VP-C-203 D 6400 VP-C-603 D 650 4.5 17800 14.6 4.5 16800290 600 VP-C-303 D 345 2.5 9300 14.0 2.5 8300 300 2.5 VP-C-303 D 345 9300 VP-C-803 D 865 6.0 22800 13.0 6.0 21300 800 VP-C-403 D 465 3.3 11700 13.8 3.3 9600 360 VP-C-403 D 11700 VP-C-1003 D 1045 7.5 28200 13.5 7.5 27800465 950 3.3 VP-C-503 D 540 3.9 14200 15.7 3.9 14100540 475 VP-C-503 D 14200 VP-C-1203 D 1100 9.0 32600 13.6 9.0 31100 1100 3.9 VP-C-603 D 650 4.5 17800 14.6 4.5 16800650 600 4.5 VP-C-603 D 17800 Cooling based upon 80.6°F DB, 66.2°F WB entering air temperature, 86.0 °F entering liquid temperature. VP-C-803 D 865 6.0 22800 13.0 6.0 21300865 800 6.0 VP-C-803 D 22800 VP-C-1003 D 1045 7.5 28200 13.5 7.5 27800 950 7.5 VP-C-1003 D 1045 28200 VP-C-1203 D 1100 9.0 32600 13.6 9.0 31100 1100 9.0 VP-C-1203 D 1100 32600 Model Cooling based upon 80.6°F DB, 66.2°F WB entering air temperature, 86.0 °F entering liquid temperature. Cooling based upon 80.6°F DB, 66.2°F WB entering air temperature, 86.0 °F enterin Heating based upon 2 row coil, 70°F DB entering air temperature, 105°F entering liquid temperature. Performance based upon 208/60/1 voltage VP-C-203 D Model D VP-C-303 VP-C-403 D R-410A Refrigerant Estimated Ship Weight Heating based upon 2 row coil, 70°F DB entering air temperature, 105°F entering liquid temperature. Heating based upon 2 row coil, 70°F DB entering air temperature, 105°F entering liq VP-C-503 D Model based Compressor Voltage Charge Fan Motor Performance Cabinet / Chassis Performance upon 208/60/1 voltage VP-C-203 D based upon 208/60/1 voltage VP-C-603 D (oz.) (lbs) VP-C-303 D VP-C-803 D VP-C-403 D VP-C-203 D Rotary 23 PSC, EC 153 / 88 VP-C-1003 D VP-C-503 D VP-C-303 D Rotary 24 PSC, EC 153 / 90 VP-C-1203 D VP-C-603 D VP-C-403 D Rotary 26.3 PSC, EC 153 / 93 VP-C-803 D VP-C-503 D Rotary 208-230/60/1 34 PSC, EC 173 / 135 VP-C-1003 D VP-C-603 D Rotary 265/60/1 34 PSC, EC 173 / 136 VP-C-1203 D VP-C-803 D Rotary 36 EC 173 / 148 VP-C-1003 D Scroll 46 EC 192 / 183 VP-C-1203 D Scroll 51 EC 192 / 194 -10WHALEN CO. - P.O. Box 1390 - Easton, Maryland 21601 - Tel. (410) 822-9200 - Fax (410) 822-8926 - www.whalencompany.com Notes: Take the Next Step To learn more about how The Whalen Company can help you save time and money on your next project, contact your local Whalen representative, call 410-822-9200 to speak with one of our specialists, or e-mail your request to sales@whalencompany.com. Additional technical resources, including dimensional drawings and Revit models, are available on our website at www.whalencompany.com or at http://seek.autodesk.com. Behind every unit that carries the Whalen name is a singularity of purpose: the engineering and manufacturing of products that improve the quality of life for our customers. Our long-term commitment to this endeavor assures you of systems that are distinctive in concept, performance, reliability and value. The number of industry “firsts” from Whalen is impressive. They include: • The industry’s first vertical stack valveless fan coils • The first vertical stack heat pump offering • The first removable chassis closet-type heat pumps • The first AHRI-listed water-cooled air conditioning units with hydronic heat Your Whalen Representative: Let us put Whalen innovation to work for you, too. Find out how our approach to your project will deliver a “perfect fit” solution – and make your life easier. P.O. Box 1390 • Easton, MD 21601 USA Tel. 410-822-9200 • Fax: 410-822-8926 www.whalencompany.com Closetline, Closetpack, Whisperline and Whisperpack are trademarks of The Whalen Company. ©2015 The Whalen Company. All rights reserved. CAS-WA-WL-ALL-rev. 0615