Water Source Heat Pump - All Product Guide

WATER SOURCE / GEOTHERMAL HEAT PUMPS AND AIR CONDITIONERS
Water Source / Geothermal
Heat Pumps & Air Conditioners
WHISPERLINE VERTICAL STACK
TM
u Classic Heat Pump / Air Conditioner
u
Single Riser Heat Pump / Air Conditioner
WHISPERLINE DUCTED VERTICAL
TM
u
Classic Heat Pump / Air Conditioner
with Slide-out Chassis
u
Single Riser Heat Pump / Air Conditioner
with Slide-out Chassis
u Water-Source Heat Pump / Air Conditioner
with Fixed Chassis
WHISPERLINE HORIZONTAL
TM
u Heat Pump / Air Conditioner with Slide-out Chassis
WHISPERPACK VERTICAL STACK
TM
u Air Conditioner with Hydronic Heating
WHISPERPACK DUCTED VERTICAL
TM
u
Air Conditioner with Hydronic Heating and
Slide-out Chassis
… From the pioneer in vertical stack HVAC technology and innovation.
P. O. Box 1390 • Easton, MD 21601 USA
Tel. (410) 822-9200 • www.whalencompany.com
Thank you for your interest in The Whalen Company. This catalog includes basic
information on our comprehensive line of commercial air handlers and fan coil
products.
Additional data is available at www.whalencompany.com where you can
download the most current product specifications. You may also contact us at
410-822-9200 or sales@whalencompany.com.
PRODUCT DESCRIPTION
KEY
WSHP - Water Source Heat Pump
GHP - Geothermal Heat Pump
WSAC - Water Source Air Conditioner
WLHP - Water Loop Heat Pump
PAGE
WHISPERLINE SERIES
TM
Classic
WSHP/GHP/WSAC applications
Vertical stack with slide-out chassis
½ to 3 Tons
200 to 1200 Cfm
3
Single Riser System with integral pump
WSHP/GHP/WSAC applications
Vertical stack with slide-out chassis
½ to 3 Tons
200 to 1200 Cfm
4
Ducted Vertical Products
Classic
WSHP/GHP/WSAC applications
Ducted vertical with slide-out chassis
½ to 3 Tons
200 to 1200 Cfm
5
Single Riser System with integral pump
WSHP/GHP/WSAC applications
Ducted vertical with slide-out chassis
½ to 3 Tons
200 to 1200 Cfm
6
WWSVX Water Source Heat Pump
WLHP applications
Ducted vertical with fixed chassis
1 ½ to 5 Tons
7
Horizontal Products
WWSHX Water Source Heat Pump
WLHP applications
Ducted horizontal unit
¾ to 5 Tons
8
WHISPERPACK SERIES
TM
Vertical Stack Products
Whisperpack Water Source AC with Hydronic Heating
WSHP/WSAC applications
Vertical Stack with slide-out chassis
½ to 3 Tons
200 to 1200 Cfm
TM
9
Ducted Vertical Products
Whisperpack Water Source AC with Hydronic Heating
WSHP/WSAC applications
Ducted vertical with slide-out chassis
½ to 3 Tons
200 to 1200 Cfm
TM
10
-2WHALEN CO. - P.O. Box 1390 - Easton, Maryland 21601 - Tel. (410) 822-9200 - Fax (410) 822-8926 - www.whalencompany.com
Whisperline Vertical Stack
TM
Classic
Water Source/Geothermal Heat Pump and Air Conditioner
A proven time and money saving concept in air conditioning
any type of building... advantageous for both new construction
and the renovation of apartments, condominiums, hotels,
senior living facilities, dormitories and office buildings.
Features:
•
•
•
•
•
•
Tons
½
¾
1
Tons
1¼
½
1½
¾
2
1
2½
1¼
3
1½
2
2½
3
Flexible configuration
Efficient operation
Low installed cost
Reduced maintenance costs
Small footprint
Clean and quiet operation
Vertical Stack
Whisperline
Classic Classic
Vertical
Stack
Whisperline
TM
Model
3.2
3.2
3.2
Risers
A - Water Source and Geothermal Heat Pump
VI-A-403 S
A1 - Water Source Heat Pump with Electric Heat (Boilerless Design)
VI-A-503 D
A2 - Water Source/Geothermal Heat Pump with Electric Heat (Supplemental)
¾
VI-A-603 S
B - Water Source Air Conditioning Unit with Electric Heat
VI-A-803 D
D - Water Source Air Conditioning Unit
VI-A-1003 D
VI-A-1203 D
Model
Tons
½
VI-A-303 S
VI-A-203 S
COP
Applications
VI-A-203 S
Standard
1
Master
1¼
Slave
1½
Special
2
2½
AHRI Certified - ASHRAE/ANSI/AHRI/ISO
Standard 13256-1
CFM
280
GPM
1.5
Model S
VI-A-303
CFM
340
GPM
2.5
VI-A-403 S
420
3.3
3
Water Loop Heat Pump
Ground Loop Heat Pump
Cooling 86°F
Heating 68°F
Cooling 77°F
Heating 32°F
Capacity Btuh
EER Btuh / W AHRI
Capacity
Btuh- ASHRAE/ANSI/AHRI/ISO
COP
Capacity Btuh
EER
Btuh / W
Capacity Btuh
COP
Certified
Standard
13256-1
6,500
13.0
8,300
5.1
6,900
14.2Loop CFM
5,200GPM
3.2
Model
Water
Loop Heat Pump
Ground
Heat Pump
9,300
13.8
Cooling 86°F
11,800
13.8
Capacity Btuh
EER Btuh / W
VI-A-503 D
540
3.9
14,600
VI-A-203 S
280
1.5
6,500
VI-A-603 S
630
4.5
18,000
VI-A-303 S
340
2.5
9,300
VI-A-803 D
830
6.0
23,000
VI-A-403 S
420
3.3
11,800
VI-A-1003 D
970
7.5
29,200
VI-A-503 D
540
3.9
14,600
VI-A-1203 D
1170
9.0
33,100
VI-A-603 S
630
4.5
18,000
Cooling based upon 80.6°F DB, 66.2°F WB entering air temperature
VI-A-803 D
830
6.0
23,000
16.7
13.0
14.5
13.8
13.1
13.8
14.2
16.7
14.2
14.5
12,000
5.2
18,400
8,300
21,700
12,000
30,000
14,900
35,900
18,400
42,000
21,700
6.0
5.1
5.0
5.2
5.0
5.0
5.0
6.0
5.2
5.0
30,000
5.0
Heating 68°F
14,900
5.0
Capacity Btuh
COP
13.1
Water L
Cooling 86°F
Cooling 77°F
Heating 32°FCapacity Btuh
EER Btu
12,500
15.8
9,600
3.2
Capacity Btuh
EER
Btuh
COP6,500
VI-A-203
S / W 280Capacity Btuh
1.5
13.0
9,650
15,200
6,900
18,800
9,650
25,000
12,500
29,700
15,200
33,600
18,800
25,000
3.5
VI-A-1003 D
970
7.5
29,200
14.2
35,900
5.0
29,700
3.2
VI-A-1203 D
1170
9.0
33,100
14.2
42,000
5.2
33,600
3.2
3.2
3.3
Cooling based upon 80.6°F DB, 66.2°F WB entering air temperature
Heating based upon 68°F DB, 59°F WB entering air temperature
14.8
17.7
14.2
VI-A-303
S
15.5
14.8
VI-A-403
S
14.5
15.8
VI-A-503
D
15.5
17.7
VI-A-603
S
15.3
15.5
VI-A-803
D
14.5D
VI-A-1003
340
420
540
630
830
970
7,160
3.2
11,000
5,200
13,000 2.5
7,160
19,000 3.3
9,600
22,000 3.9
11,000
25,400 4.5
13,000 6.0
19,000 7.5
3.5
3.2 9,300
3.2
3.2 11,800
3.2
3.2 14,600
3.2
3.5
3.3 18,000
3.2 23,000
3.2 29,200
15.5D
22,000 9.0
3.2 33,100
VI-A-1203
1170
25,400
3.3air temperature
Cooling 15.3
based upon 80.6°F DB,
66.2°F WB entering
13.8
13.8
16.7
14.5
13.1
14.2
14.2
Mode
VI-A-203
Performance based upon 208/60/1 voltage
Mode
VI-A-303
Heating based upon 68°F DB, 59°F WB entering air temperature
R-410A Refrigerant
Performance based upon 208/60/1 voltage
Model
Compressor
Charge
(oz.)
Fan Motor
Voltage
Estimated Ship
Weight
Cabinet / Chassis
(lbs)
Heating based upon 68°F DB, 59°F WB entering air temperature
Performance based upon 208/60/1 voltage
145 / 85
VI-A-403
VI-A-503
VI-A-203
VI-A-603
VI-A-303
VI-A-803
VI-A-403
VI-A-100
VI-A-503
VI-A-120
VI-A-603
VI-A-203 S
Rotary
23.5
PSC, EC
VI-A-303 S
Rotary
26
PSC, EC
145 / 87
VI-A-403 S
Rotary
25.25
PSC, EC
145 / 89
VI-A-803
VI-A-503 D
Rotary
33.5
PSC, EC
208-230/60/1
165 / 128
VI-A-100
VI-A-603 S
Rotary
35
PSC, EC
265/60/1
165 / 129
VI-A-120
VI-A-803 D
Rotary
38
EC
VI-A-1003 D
Scroll
48.5
EC
185 / 171
VI-A-1203 D
Scroll
54
EC
185 / 181
165 / 138
-3WHALEN CO. - P.O. Box 1390 - Easton, Maryland 21601 - Tel. (410) 822-9200 - Fax (410) 822-8926 - www.whalencompany.com
Whisperline Vertical Stack
TM
Single Riser System with Integral Pump
Water Source/Geothermal Heat Pump and Air Conditioner
By using only one riser to distribute fluid to a heat pump
when two pipes are usually required, allows designers to
specify a single riser size to help control costs during initial
and payout phases of construction.
Features:
•
•
•
•
•
•
Tons
½
¾
1
Tons
1¼
½
1½
¾
2
1
2½
1¼
3
1½
2
2½
3
Superior comfort
Efficient, clean and quiet operation
Robust, energy-saving “green” design
Small footprint ... flexible configurations
Reduced project design requirements
Lower installation cost ... lower O&M costs
Vertical
Stack
Whisperline
Single
Riser
System
(SRS)Pump
with Integral Pump
Vertical Stack
Whisperline
Single Riser
System
(SRS)
with Integral
TM
Model
Applications
A - Water Source and Geothermal Heat Pump
VI-A-403 S
A1 - Water Source Heat Pump with Electric Heat (Boilerless Design)
VI-A-503 D
A2 - Water Source/Geothermal Heat Pump with Electric Heat (Supplemental)
VI-A-603 S
B - Water Source Air Conditioning Unit with Electric Heat
D - Water Source Air Conditioning Unit
Model
CFM
3.2
3.2
3.5
3.2
280
Cooling 86°F
1.5
CFM
340
GPM
2.5
VI-A-403 S
420
3.3
1
Master
1¼
Slave
1½
Special
2
Water Loop Heat Pump
GPM
Model S
VI-A-303
Standard
AHRI Certified - ASHRAE/ANSI/AHRI/ISO
Standard 13256-1
2½
VI-A-1003 D
VI-A-203 S
3.2
¾
VI-A-803 D
VI-A-1203 D
Tons
½
VI-A-303 S
Capacity Btuh
COP
Risers
VI-A-203 S
6,500
EER Btuh / W
VI-A-503 D
540
3.9
14,600
VI-A-203 S
280
1.5
6,500
VI-A-603 S
630
4.5
18,000
VI-A-303 S
340
2.5
9,300
VI-A-803 D
830
6.0
23,000
VI-A-403 S
420
3.3
11,800
VI-A-1003 D
970
7.5
29,200
VI-A-503 D
540
3.9
14,600
VI-A-1203 D
1170
9.0
33,100
VI-A-603 S
630
4.5
18,000
Cooling based upon 80.6°F DB, 66.2°F WB entering air temperature
VI-A-803 D
830
6.0
23,000
16.7
13.0
14.5
13.8
13.1
13.8
14.2
16.7
14.2
14.5
Cooling 77°F
Capacity
Btuh- ASHRAE/ANSI/AHRI/ISO
COP
Capacity Btuh
EER
Btuh / W
AHRI
Certified
Standard
13256-1
13.0
8,300
Water
Loop Heat Pump
9,300 Cooling 86°F 13.8
11,800
13.8
Capacity Btuh
EER Btuh / W
Ground Loop Heat Pump
3
Heating 68°F
5.1
12,000
Heating 68°F 5.2
14,900
5.0
Capacity Btuh
COP
COP
Water
14.2Loop Heat Pump
5,200
3.2
Ground
Model
CFM
GPM
Cooling
86°F
9,650 Cooling 77°F 14.8
7,160
3.2
Heating 32°F
12,500
15.8
9,600
3.2
Capacity
Btuh
EER Btu
Capacity Btuh
EER Btuh / W
Capacity Btuh
COP
6,900
18,400
8,300
21,700
12,000
30,000
14,900
35,900
18,400
42,000
21,700
6.0
5.1
5.0
5.2
5.0
5.0
5.0
6.0
5.2
5.0
15,200
6,900
18,800
9,650
25,000
12,500
29,700
15,200
33,600
18,800
13.1
30,000
5.0
25,000
VI-A-1003 D
970
7.5
29,200
14.2
35,900
5.0
29,700
VI-A-1203 D
1170
9.0
33,100
14.2
42,000
5.2
33,600
3.2
Cooling based upon 80.6°F DB, 66.2°F WB entering air temperature
3.2
Heating based upon 68°F DB, 59°F WB entering air temperature
3.3
Performance based upon 208/60/1 voltage
17.7
11,000 1.5
3.5 6,500
VI-A-203
S
280
14.2
5,200
3.2
15.5
13,000 2.5
3.2 9,300
VI-A-303
S
340
14.8
7,160
3.2
14.5
19,000 3.3
3.211,800
VI-A-403
S
420
15.8
9,600
3.2
15.5
22,000 3.9
3.214,600
VI-A-503
D
540
17.7
11,000
3.5
15.3
25,400 4.5
3.318,000
VI-A-603
S
630
15.5
13,000
3.2
VI-A-803 D
830
6.0
23,000
14.5
19,000
3.2
VI-A-1003 D
970
7.5
29,200
15.5
22,000
3.2
VI-A-1203 D
1170
9.0
33,100
15.3
25,400
3.3
Cooling based upon 80.6°F DB, 66.2°F WB entering air temperature
13.
13.
13.
16.
14.
13.
14.
14.
Mode
VI-A-20
Mode
VI-A-30
Heating based upon 68°F DB, 59°F WB entering
temperature
R-410AairRefrigerant
Performance
upon 208/60/1 voltage
Model basedCompressor
Heating 32°F
Capacity Btuh
Charge
(oz.)
Fan Motor
Voltage
Estimated Ship
Weight
Cabinet / Chassis
(lbs)
Heating based upon 68°F DB, 59°F WB entering air temperature
Performance based upon 208/60/1 voltage
145 / 85
VI-A-40
VI-A-50
VI-A-20
VI-A-60
VI-A-30
VI-A-80
VI-A-40
VI-A-100
VI-A-50
VI-A-120
VI-A-60
VI-A-203 S
Rotary
23.5
PSC, EC
VI-A-303 S
Rotary
26
PSC, EC
145 / 87
VI-A-403 S
Rotary
25.25
PSC, EC
145 / 89
VI-A-80
VI-A-503 D
Rotary
33.5
PSC, EC
208-230/60/1
165 / 128
VI-A-100
VI-A-603 S
Rotary
35
PSC, EC
265/60/1
165 / 129
VI-A-120
VI-A-803 D
Rotary
38
EC
VI-A-1003 D
Scroll
48.5
EC
185 / 171
VI-A-1203 D
Scroll
54
EC
185 / 181
165 / 138
-4WHALEN CO. - P.O. Box 1390 - Easton, Maryland 21601 - Tel. (410) 822-9200 - Fax (410) 822-8926 - www.whalencompany.com
Whisperline Ducted Vertical with Slide-out Chassis
TM
Classic
Water Source/Geothermal Heat Pump and Air Conditioner
A vertical unit requiring access on only one side and serviceability that
provides added flexibility over traditional units. Used in a variety of
new and renovation construction projects similar to apartments,
dormitories and office buildings.
Only one side access required with slide-out chassis.
Features:
•
•
•
•
•
Flexible configurations
Efficient operation
Reduced maintenance costs
Small footprint
Clean and quiet operation
Tons
½
¾
1
Tons
1¼
½
1½
¾
2
1
2½
1¼
3
1½
Closetline CLASSICDucted Classic
Whisperline
TM
Model
Applications
Risers
VI-A-203 S
½
VI-A-303 S
A - Water Source and Geothermal Heat Pump
VI-A-403 S
A1 - Water Source Heat Pump with Electric Heat (Boilerless Design)
VI-A-503 D
A2 - Water Source/Geothermal Heat Pump with Electric Heat (Supplemental)
¾
VI-A-603 S
B - Water Source Air Conditioning Unit with Electric Heat
2
VI-A-803 D
D - Water Source Air Conditioning Unit
2½
VI-A-1003 D
3
VI-A-1203
Model D
CFM
COP
3.2
3.2
3.2
3.5
3.2
3.2
3.2
3.3
280
Model S
VI-A-303
CFM
340
GPM
2.5
VI-A-403 S
420
3.3
1
Master
1¼
Slave
1½
2
AHRI Certified - ASHRAE/ANSI/AHRI/ISO Standard 13256-1
2½
Water Loop Heat Pump
GPM
1.5
Standard
Special
Cooling 86°F
CapacityBtuh
VI-A-203 S
Tons
EER Btuh / W
6,500
Cooling 77°F
Capacity
Btuh- ASHRAE/ANSI/AHRI/ISO
COP
Capacity Btuh
EER
Btuh / W
AHRI
Certified
Standard
13256-1
13.0
8,300
5.1
Water
Loop Heat Pump
9,300
12,000
Cooling 86°F 13.8
Heating 68°F 5.2
11,800
13.8
14,900
5.0
CapacityBtuh
EER Btuh / W
Capacity Btuh
COP
VI-A-503 D
540
3.9
14,600
VI-A-203 S
280
1.5
6,500
VI-A-603 S
630
4.5
18,000
VI-A-303 S
340
2.5
9,300
VI-A-803 D
830
6.0
23,000
VI-A-403 S
420
3.3
11,800
VI-A-1003 D
970
7.5
29,200
VI-A-503 D
540
3.9
14,600
VI-A-1203 D
1170
9.0
33,100
VI-A-603 S
630
4.5
18,000
Cooling based upon 80.6°F DB, 66.2°F WB entering air temperature
VI-A-803 D
830
6.0
23,000
Ground Loop Heat Pump
3
Heating 68°F
16.7
13.0
14.5
13.8
13.1
13.8
14.2
16.7
14.2
14.5
18,400
8,300
21,700
12,000
30,000
14,900
35,900
18,400
42,000
21,700
6.0
5.1
5.0
5.2
5.0
5.0
5.0
6.0
5.2
5.0
13.1
30,000
COP
6,900
14.2Loop Heat Pump
5,200
3.2
Water
Ground
Model
CFM
9,650
7,160GPM
Cooling 86°F
Cooling 77°F 14.8
Heating 32°F 3.2
12,500
15.8
9,600
3.2
CapacityBtuh
EER Btu
Capacity Btuh
EER Btuh / W
Capacity Btuh
COP
15,200
6,900
18,800
9,650
25,000
12,500
29,700
15,200
33,600
18,800
17.7
VI-A-203
S
14.2
15.5
VI-A-303
S
14.8
14.5
VI-A-403
S
15.8
15.5
VI-A-503
D
17.7
15.3
VI-A-603
S
15.5
5.0
25,000
VI-A-1003 D
970
7.5
29,200
14.2
35,900
5.0
29,700
VI-A-1203 D
1170
9.0
33,100
14.2
42,000
5.2
33,600
Cooling based upon 80.6°F DB, 66.2°F WB entering air temperature
Heating 32°F
Capacity Btuh
630
11,000
5,200 1.5
13,000
7,160 2.5
19,000
9,600 3.3
22,000
11,000 3.9
25,400
13,000 4.5
3.5
3.2 6,500
3.2
3.2 9,300
3.2
3.2 11,800
3.2
3.5 14,600
3.3
3.2 18,000
VI-A-803
D
14.5
830
19,000 6.0
3.2 23,000
13.
VI-A-1003
15.5D
970
22,000 7.5
3.2 29,200
14.
280
340
420
540
VI-A-1203
1170
15.3D
25,400 9.0
3.3 33,100
Cooling based upon 80.6°F DB, 66.2°F WB entering air temperature
13.
13.
13.
16.
14.
14.
Mode
Heating based upon 68°F DB, 59°F WB entering air temperature
VI-A-20
Performance based upon 208/60/1 voltage
R-410AairRefrigerant
Heating based upon 68°F DB, 59°F WB entering
temperature
Model based Compressor
Performance
upon 208/60/1 voltage
Charge
(oz.)
Fan Motor
Voltage
Estimated Ship
Weight
Cabinet / Chassis
(lbs)
VI-A-203 S
Rotary
23.5
PSC, EC
VI-A-303 S
Rotary
26
PSC, EC
145 / 87
VI-A-403 S
Rotary
25.25
PSC, EC
145 / 89
VI-A-503 D
Rotary
33.5
PSC, EC
208-230/60/1
165 / 128
VI-A-603 S
Rotary
35
PSC, EC
265/60/1
165 / 129
Mode
VI-A-30
Heating based upon 68°F DB, 59°F WB entering air temperature
Performance based upon 208/60/1 voltage
145 / 85
VI-A-803 D
Rotary
38
EC
165 / 138
VI-A-1003 D
Scroll
48.5
EC
185 / 171
VI-A-1203 D
Scroll
54
EC
185 / 181
-5WHALEN CO. - P.O. Box 1390 - Easton, Maryland 21601 - Tel. (410) 822-9200 - Fax (410) 822-8926 - www.whalencompany.com
VI-A-40
VI-A-503
VI-A-203
VI-A-60
VI-A-303
VI-A-803
VI-A-403
VI-A-100
VI-A-503
VI-A-120
VI-A-603
VI-A-803
VI-A-100
VI-A-120
Whisperline Ducted Vertical with Slide-out Chassis
TM
Single Riser System with Integral Pump
Water Source/Geothermal Heat Pump and Air Conditioner
By using only one riser to distribute fluid to a heat pump when
two pipes are usually required, this unit allows designers to
specify a single riser size to help control costs during initial
and payout phases of construction.
Only one side access required with slide-out chassis.
Features:
•
•
•
•
•
Tons
½
¾
1
Tons
1¼
½
1½
¾
2
1
2¼
½
1
1 3½
2
2½
3
Efficient, clean and quiet operation
Robust, energy-saving “green” design
Small footprint ... flexible configurations
Reduced project design requirements
Lower installation cost ... lower O&M costs
Whisperline
Single
Riser
(SRS) with Integral Pump
Closetline Single Ducted
Riser System
(SRS)
with System
Integral Pump
TM
Model
VI-A-403 S
A1 - Water Source Heat Pump with Electric Heat (Boilerless Design)
VI-A-503 D
A2 - Water Source/Geothermal Heat Pump with Electric Heat (Supplemental)
VI-A-603 S
B - Water Source Air Conditioning Unit with Electric Heat
D - Water Source Air Conditioning Unit
Model
3.2
CFM
GPM
280
1.5
CFM
GPM
340
2.5
VI-A-403 S
420
3.3
VI-A-503 S
D
VI-A-203
VI-A-603 S
S
VI-A-303
540
280
630
340
3.9
1.5
4.5
2.5
VI-A-803 S
D
VI-A-403
VI-A-1003
VI-A-503 DD
VI-A-1203
VI-A-603 SD
830
420
970
540
1170
630
Standard
1
Master
1¼
Slave
1½
Special
2
2 ½ Standard 13256-1
AHRI Certified - ASHRAE/ANSI/AHRI/ISO
3
Water Loop Heat Pump
Ground Loop Heat Pump
VI-A-1003 D
Model
3.2
¾
VI-A-803 D
VI-A-1203 D
Tons
½
A - Water Source and Geothermal Heat Pump
VI-A-203 S
3.2
Risers
VI-A-303 S
VI-A-303 S
COP
Applications
VI-A-203 S
Cooling 86°F
Heating 68°F
Cooling 77°F
Heating 32°F
Certified
Standard
13256-1
Capacity Btuh
EER Btuh / W AHRI
Capacity
Btuh- ASHRAE/ANSI/AHRI/ISO
COP
Capacity Btuh
EER
Btuh / W
Capacity Btuh
COP
Wate
6,500
13.0
8,300
5.1
6,900
14.2
5,200 GPM
3.2
Water
Loop Heat Pump
Ground
Loop Heat
Pump
Model
CFM
Cooling 86°F
9,300 Cooling 86°F 13.8
12,000
9,650 Cooling 77°F 14.8
7,160
Heating 68°F 5.2
Heating 32°F 3.2
Capacity
Btuh
EER B
11,800Btuh
13.8 / W
14,900Btuh
5.0
12,500Btuh
15.8 / W
9,600 Btuh
3.2
Capacity
EER Btuh
Capacity
COP
Capacity
EER Btuh
Capacity
COP
6.0
3.3
7.5
3.9
9.0
4.5
14,600
6,500
18,000
9,300
23,000
11,800
29,200
14,600
33,100
18,000
Cooling
based
80.6°F DB, 6.0
66.2°F WB entering
air temperature
VI-A-803
D upon830
23,000
16.7
13.0
14.5
13.8
13.1
13.8
18,400
8,300
21,700
12,000
30,000
14,900
6.0
5.1
5.0
5.2
5.0
5.0
15,200
6,900
18,800
9,650
14.2
16.7
14.2
14.5
35,900
18,400
42,000
21,700
5.0
6.0
5.2
5.0
25,000
12,500
29,700
15,200
33,600
18,800
13.1
30,000
5.0
25,000
3.5
VI-A-1003 D
970
7.5
29,200
14.2
35,900
5.0
29,700
3.2
VI-A-1203 D
1170
9.0
33,100
14.2
42,000
5.2
33,600
3.2
Cooling based upon 80.6°F DB, 66.2°F WB entering air temperature
3.2
Heating based upon 68°F DB, 59°F WB entering air temperature
3.3
17.7
VI-A-203
S
14.2
15.5
VI-A-303
S
14.8
14.5
VI-A-403
S
15.8
15.5
VI-A-503
D
17.7
15.3
VI-A-603
S
15.5
VI-A-803
D
14.5
VI-A-1003
D
15.5
280 11,000
5,200 1.5
340 13,000
7,160 2.5
420 19,000
9,600 3.3
540 22,000
11,000 3.9
25,400 4.5
630 13,000
830 19,000 6.0
3.5 6,500
3.2
3.2 9,300
3.2
3.2 11,800
3.2
3.2 14,600
3.5
3.3 18,000
3.2
3.2 23,000
3.2 29,200
13
16
14
13
970 22,000 7.5
14
VI-A-1203
D
117025,400 9.0
14
15.3
3.3 33,100
Mod
Cooling based upon 80.6°F DB, 66.2°F WB entering air temperature
VI-A-2
Performance based upon 208/60/1 voltage
Mod
VI-A-3
Heating based upon 68°F DB, 59°F WB entering
temperature
R-410AairRefrigerant
Performance
upon 208/60/1 voltage
Model based Compressor
13
13
Charge
(oz.)
Fan Motor
23.5
PSC, EC
Voltage
Estimated Ship
Weight
Cabinet / Chassis
(lbs)
Heating based upon 68°F DB, 59°F WB entering air temperature
VI-A-4
Performance based upon 208/60/1 voltage
VI-A-5
VI-A-2
VI-A-6
VI-A-3
145 / 85
VI-A-8
VI-A-4
VI-A-10
VI-A-5
VI-A-12
VI-A-6
VI-A-203 S
Rotary
VI-A-303 S
Rotary
26
PSC, EC
145 / 87
VI-A-403 S
Rotary
25.25
PSC, EC
145 / 89
VI-A-8
VI-A-503 D
Rotary
33.5
PSC, EC
208-230/60/1
165 / 128
VI-A-10
VI-A-603 S
Rotary
35
PSC, EC
265/60/1
165 / 129
VI-A-12
VI-A-803 D
Rotary
38
EC
VI-A-1003 D
Scroll
48.5
EC
185 / 171
VI-A-1203 D
Scroll
54
EC
185 / 181
165 / 138
-6WHALEN CO. - P.O. Box 1390 - Easton, Maryland 21601 - Tel. (410) 822-9200 - Fax (410) 822-8926 - www.whalencompany.com
Whisperline Ducted Vertical with Fixed Chassis
TM
WWSVC/WWSVX Water Source Heat Pump and A/C
1-1/2 thru 5 Tons
Available with energy saving ECM motor
Features:
• 100% Factory run tested.
• All units operate with environmentally friendly R-410 refrigerant.
• Heavy Gauge Galvanized Steel Cabinet.
• Cabinets insulated with ¾” Tuf-Skin RX™ treated with an anti-microbial agent.
• Non-corrosive Thermoplastic Condensate Pan, sloped for positive drainage.
• High and Low pressure Service Ports.
• Refrigerant Filter-drier and Discharge Muffler.
• Coaxial water-to-refrigerant heat exchanger.
• Heat exchanger available in Copper or CuproNickel.
• Digital Control Module (DCM).
• Reversable Blower.
• Multi-speed blower motor.
• Panel-mounted FPT Water Connections.
• High efficiency rotary or scroll compressor.
• System reversing valve (4-way).
• Large Removable Panels for Service access.
• 50 VA Transformer.
• 1” Throwaway Filter.
• 208/230/1PH
ASHRAE/ANSI/AHRI/ISO Standard 13256-1
Water Loop Heat Pump
Cooling 86°F
Heating 68°F
Capacity
EER
Capacity
COP
Btuh
Btuh / W
Btuh
Model
CFM
GPM
WWSVC009
300
3.0
8,000
13.0
11,200
4.2
WWSVC012
340
3.5
11,000
13.0
14,000
4.2
WWSVC018
550
6.1
17,400
13.0
22,700
4.2
WWSVC024
380
6.6
23,000
13.0
30,500
4.2
WWSVC030
930
8.8
27,600
13.0
36,400
4.2
WWSVC036
970
10.5
33,400
13.0
45,000
4.2
WWSVC042
1250
11.6
39,000
13.0
50,000
4.2
WWSVC048
1400
14.0
46,800
13.0
58,100
4.2
WWSVC060
1760
15.5
59,000
13.0
68,100
4.2
Model
CFM
GPM
ASHRAE/ANSI/AHRI/ISO Standard 13256-1
Water Loop Heat Pump
Cooling 86°F
Heating 68°F
Capacity
EER
Capacity
COP
Btuh
Btuh / W
Btuh
WWSVX018
550
5.0
17,000
14.0
21,000
4.3
WWSVX024
380
6.1
23,400
14.2
28,000
4.3
WWSVX030
930
9.0
28,000
14.0
32,800
4.3
WWSVX036
970
10.0
33,000
14.0
42,100
4.3
WWSVX042
1250
10.5
40,500
14.0
47,500
4.4
WWSVX048
1400
12.5
47,100
14.0
53,800
4.3
WWSVX060
1760
15.5
56,000
14.0
69,300
4.3
Model
Width
Depth
Height
WWSVC009
21.5
21.5
28.25
WWSVC012
21.5
21.5
28.25
WWSVC018
21.5
21.5
36.25
WWSVC024
21.5
21.5
36.25
WWSVC030
21.5
21.5
39.25
WWSVC036
21.5
21.5
39.25
WWSVC042
21.5
26.0
43.25
WWSVC048
26.0
26.0
43.25
WWSVC060
26.0
26.0
43.25
-7WHALEN CO. - P.O. Box 1390 - Easton, Maryland 21601 - Tel. (410) 822-9200 - Fax (410) 822-8926 - www.whalencompany.com
Whisperline Horizontal
TM
WWSHC/WWSHX Horizontal Water Source Heat Pump and A/C
3/4 thru 5 Tons
Available with energy saving ECM motor
Features:
• 100% Factory run tested.
• All units operate with environmentally friendly R-410 refrigerant.
• Heavy Gauge Galvanized Steel Cabinet.
• Cabinets insulated with ¾” Tuf-Skin RX™ treated with an anti-microbial agent.
• Non-corrosive Thermoplastic Condensate Pan, sloped for positive drainage.
• High and Low pressure Service Ports.
• Refrigerant Filter-drier and Discharge Muffler.
• Coaxial water-to-refrigerant heat exchanger.
• Heat exchanger available in Copper or CuproNickel.
• Digital Control Module (DCM).
• Multi-speed blower motor.
• Panel-mounted FPT Water Connections.
• High efficiency rotary or scroll compressor.
• System reversing valve (4-way).
• Large Removable Panels for Service access.
• 50 VA Transformer.
• 1” Throwaway Filter.
• 208/230/1PH
• Other voltages available contact factory.
ASHRAE/ANSI/AHRI/ISO Standard 13256-1
Water Loop Heat Pump
Cooling 86°F
Heating 68°F
Capacity
EER
Capacity
COP
Btuh
Btuh / W
Btuh
Model
CFM
GPM
WWSHC009
300
3.0
8,000
13.0
11,200
4.2
WWSHC012
340
3.5
11,000
13.0
14,000
4.2
WWSHC018
550
6.1
17,400
13.0
22,700
4.2
WWSHC024
380
6.6
23,000
13.0
30,500
4.2
WWSHC030
930
8.8
27,600
13.0
36,400
4.2
WWSHC036
970
10.5
33,400
13.0
45,000
4.2
WWSHC042
1250
11.6
39,000
13.0
50,000
4.2
WWSHC048
1400
14.0
46,800
13.0
58,100
4.2
WWSHC060
1760
15.5
59,000
13.0
68,100
4.2
ASHRAE/ANSI/AHRI/ISO Standard 13256-1
Water Loop Heat Pump
Cooling 86°F
Heating 68°F
Capacity
EER
Capacity
COP
Btuh
Btuh / W
Btuh
Model
CFM
GPM
WWSHX018
550
6.1
17,000
14.0
22,000
4.3
WWSHX024
380
6.6
23,200
14.0
30,500
4.4
WWSHX030
930
8.8
27,800
14.0
36,200
4.4
WWSHX036
970
10.5
33,500
14.0
44,600
4.5
WWSHX042
1250
11.6
39,500
14.0
49,200
4.4
WWSHX048
1400
14.0
47,200
14.0
58,100
4.4
WWSHX060
1760
15.5
60,500
14.0
63,500
4.4
Model
Length
Width
Height
WWSHC009
19.13
34.13
17.00
WWSHC012
19.13
34.13
17.00
WWSHC018
20.13
43.13
17.00
WWSHC024
20.13
43.13
18.25
WWSHC030
20.13
43.13
18.25
WWSHC036
20.13
47.13
21.00
WWSHC042
20.13
47.13
21.00
WWSHC048
24.13
54.13
21.00
WWSHC060
24.13
54.13
21.00
-8WHALEN CO. - P.O. Box 1390 - Easton, Maryland 21601 - Tel. (410) 822-9200 - Fax (410) 822-8926 - www.whalencompany.com
Whisperpack Vertical Stack
TM
Air Conditioning with Hydronic Heating
Water Source Air Conditioning with Water Heating
By packaging the best characteristics of our compressorized and
fan coil product lines, we have developed a unit that offers the
air conditioning performance we are known for with the
operational characteristics found in our proven fan coil units.
Features:
•
•
•
•
•
Flexible configurations
Package design lowers field labor cost
Incorporates energy sharing concepts
Easy maintenance
Clean and quiet operation
dronic Heating
dronic Heating
TM
dronic Heating
Vertical
StackWhisperpack
Whisperpack
Conditioning
with Hydronic
Heating
Vertical Stack
Air Air
Conditioning
with Hydronic
Heating
Model
Applications
Risers
Tons
Standard
½
¾
1
Master
Slave
1¼
1½
Special
2
VP-C-203 D
VP-C-303 D
VP-C-403 D
VP-C-503 D
VP-C-603 D
VP-C-803 D
VP-C-1003 D
VP-C-1203 D
Model
Model
VP-C-203
Model D
C - Air Conditioning
with Hydronic Heating
AHRI Certified - ASHRAE/ANSI/AHRI/ISO
Standard 13256-1
2½
Water
Loop Heat Pump
3
Cooling 86°F
CFM
GPM
AHRI
Certified - ASHRAE/ANSI/AHRI/ISO
Standard 13256-1
Capacity
EER
AHRI Certified - ASHRAE/ANSI/AHRI/ISO
Standard 13256-1
Water Loop Heat Pump
Btuh Loop Heat
Btuh
/W
Water
Pump
Cooling
86°F
290
1.5
6400 Cooling 86°F
13.7
CFM
GPM
Capacity
EER
CFM
GPM
345
2.5
9300
14.0
Capacity
EER
Btuh
Btuh
465
3.3
11700
13.8/ W
Btuh
Btuh
/W
290
1.5
6400
13.7
VP-C-303 D
VP-C-403 D
VP-C-203
VP-C-503 D
D
540
3.9
14200
15.7
VP-C-203 D
290
1.5
6400
13.7
VP-C-303
345
2.5
9300
14.0
VP-C-603 D
D
650
4.5
17800
14.6
VP-C-303 D
345
2.5
9300
14.0
VP-C-403
465
3.3
11700
13.8
VP-C-803 D
D
865
6.0
22800
13.0
VP-C-403 D
465
3.3
11700
13.8
VP-C-503 DD
540
3.9
14200
15.7
VP-C-1003
1045
7.5
28200
13.5
VP-C-503 D
540
3.9
14200
15.7
VP-C-603 DD
650
4.5
17800
14.6
VP-C-1203
1100
9.0
32600
13.6
VP-C-603 D
650
4.5
17800
14.6
VP-C-803
D
865
6.0
22800
13.0
Cooling based upon 80.6°F DB, 66.2°F WB entering air temperature, 86.0 °F entering liquid temperature.
VP-C-803 D
865
6.0
22800
13.0
VP-C-1003 D
1045
7.5
28200
13.5
VP-C-1003 D
1045
7.5
28200
13.5
VP-C-1203 D
1100
9.0
32600
13.6
VP-C-1203 D
1100
9.0
32600
13.6
Cooling based upon 80.6°F DB, 66.2°F WB entering air temperature, 86.0 °F entering liquid temperature.
Cooling based upon 80.6°F DB, 66.2°F WB entering air temperature, 86.0 °F entering liquid temperature.
Heating
GPM
Heating
Heating
1.5
GPM
Model
GPM
2.5
3.3
1.5
3.9
1.5 D
VP-C-203
2.5
4.5
2.5 D
VP-C-303
3.3
6.0
3.3 D
VP-C-403
3.9
7.5
3.9 D
VP-C-503
4.5
9.0
4.5
VP-C-603
6.0 D
6.0
VP-C-803
7.5 D
7.5 D
VP-C-1003
9.0
9.0 D
VP-C-1203
Entering Liquid Temp
Heating 105°F
Capacity
EER
Entering
Liquid
Temp
AHRI
Certified
- ASHRAE/ANSI/AHRI/ISO
Standard
Entering
Liquid
Temp
Btuh
Btuh
/W
Heating
105°F
Water Loop He
Heating
105°F
8000
270
Cooling
Capacity
EER
CFM
8300
300 GPM
Capacity
EER
Capacity
Btuh
Btuh
/
W
9600
360
Btuh
Btuh
/W
Btuh
8000
270
14100
8000
290
8300
16800
8300
345
9600
21300
9600
465
14100
27800
14100
540
16800
31100
16800
650
21300
21300
865
27800
27800
1045
31100
31100
1100
475
270
300
600
300
360
800
360
475
950
475
600
1100
600
800
800
950
950
1100
1100
1.5
2.5
3.3
3.9
4.5
6.0
7.5
9.0
6400
9300
11700
14200
17800
22800
28200
32600
M
Cooling based upon 80.6°F DB, 66.2°F WB entering air temperature, 86.0 °F entering liquid tem
Heating based upon 2 row coil, 70°F DB entering air temperature, 105°F entering liquid temperature.
Performance based upon 208/60/1 voltage
Heating based upon 2 row coil, 70°F DB entering air temperature, 105°F entering liquid temperature.
R-410A
Heating based upon 2 row coil, 70°F DB entering air temperature,
105°FRefrigerant
entering liquid temperature.
Performance based upon 208/60/1 voltage
Model based upon
Compressor
Charge
Fan Motor
Performance
208/60/1 voltage Voltage
(oz.)
VP-C-203 D
VP-C-303 D
VP-C-403 D
VP-C-503 D
VP-C-603 D
VP-C-803 D
VP-C-1003 D
VP-C-1203 D
Rotary
Rotary
Rotary
Rotary
Rotary
Rotary
Scroll
Scroll
208-230/60/1
265/60/1
23
24
26.3
34
34
36
46
51
PSC, EC
PSC, EC
PSC, EC
PSC, EC
PSC, EC
EC
EC
EC
VP-C
M
M
VP-C
Estimated Ship
VP-C
Heating
based upon 2 row coil, 70°F DB entering air temperature, 105°F entering liquid tempera
VP-C
Weight
VP-C
VP-C
Performance
based upon 208/60/1 voltage
VP-C
Cabinet
/ Chassis
VP-C
VP-C
VP-C
(lbs)
VP-C
VP-C
VP-C
153 / 88
VP-C
VP-C
VP-C
153 / 90
VP-C
VP-C
VP-C
153 / 93
VP-C
VP-C
173 / 135
VP-C
VP-C
173 / 136
VP-C
173 / 148
192 / 183
192 / 194
-9WHALEN CO. - P.O. Box 1390 - Easton, Maryland 21601 - Tel. (410) 822-9200 - Fax (410) 822-8926 - www.whalencompany.com
W
Whisperpack Ducted Vertical with Slide-out Chassis
TM
Air Conditioning with Hydronic Heating
Water Source Air Conditioning with Water Heating
By packaging the best characteristics of our compressorized
and fan coil product lines, we have developed a unit that
offers the air conditioning performance we are known for
with the operational characteristics found in our proven fan
coil units.
Only one side access required with slide-out chassis.
Features:
•
•
•
•
Package design lowers field labor cost
Incorporates energy sharing concepts
Easy maintenance
Clean and quiet operation
Closetpack Air Conditioning
with Hydronic Heating
Whisperpack
Ducted Air Conditioning
with Hydronic Heating
TM
Model
VP-C-203 D
VP-C-303 D
VP-C-403 D
VP-C-503 D
VP-C-603 D
VP-C-803 D
VP-C-1003 D
VP-C-1203 D
Model
Applications
Risers
Tons
½
¾
Standard
1
C - Air Conditioning
Master
1¼
with Hydronic Heating
Slave
1½
Special
2
AHRI Certified - ASHRAE/ANSI/AHRI/ISO Standard
13256-1
2½
Water Loop
3 Heat Pump
Cooling 86°F
CFM
GPM
AHRI Certified - ASHRAE/ANSI/AHRI/ISO Standard 13256-1
Capacity Btuh EER Btuh / W
Water Loop Heat Pump
290
1.5
6400Cooling 86°F13.7
CFM
GPM
345
2.5
9300
14.0
Capacity
465
3.3
11700Btuh EER Btuh
13.8 / W
Heating
GPM
Heating
1.5
Model
GPM
2.5
Entering Liquid Temp
Heating 105°F
AHRI Certified
- ASHRAE/ANSI/AHRI/ISO Standa
Entering
Capacity
BtuhLiquid
EERTemp
Btuh / W
Water Loop H
Heating 105°F
8000
270
Cooling
CFM
GPM
8300
300
Capacity
9600 Btuh EER Btuh
360 / W
Capacity Btuh E
VP-C-203
Model D
VP-C-303 D
VP-C-403 D
3.3
VP-C-503 D
540
3.9
14200
15.7
3.9
14100
475
VP-C-203 D
290
1.5
6400
13.7
1.5
8000
270 1.5
VP-C-203
D
6400
VP-C-603 D
650
4.5
17800
14.6
4.5
16800290
600
VP-C-303 D
345
2.5
9300
14.0
2.5
8300
300 2.5
VP-C-303
D
345
9300
VP-C-803 D
865
6.0
22800
13.0
6.0
21300
800
VP-C-403 D
465
3.3
11700
13.8
3.3
9600
360
VP-C-403
D
11700
VP-C-1003 D
1045
7.5
28200
13.5
7.5
27800465
950 3.3
VP-C-503 D
540
3.9
14200
15.7
3.9
14100540
475
VP-C-503
D
14200
VP-C-1203 D
1100
9.0
32600
13.6
9.0
31100
1100 3.9
VP-C-603 D
650
4.5
17800
14.6
4.5
16800650
600 4.5
VP-C-603
D
17800
Cooling based upon 80.6°F DB, 66.2°F WB entering air temperature, 86.0 °F entering liquid temperature.
VP-C-803 D
865
6.0
22800
13.0
6.0
21300865
800 6.0
VP-C-803
D
22800
VP-C-1003 D
1045
7.5
28200
13.5
7.5
27800
950 7.5
VP-C-1003
D
1045
28200
VP-C-1203 D
1100
9.0
32600
13.6
9.0
31100
1100 9.0
VP-C-1203
D
1100
32600 Model
Cooling based upon 80.6°F DB, 66.2°F WB entering air temperature, 86.0 °F entering liquid temperature.
Cooling based upon 80.6°F DB, 66.2°F WB entering air temperature, 86.0 °F enterin
Heating based upon 2 row coil, 70°F DB entering air temperature, 105°F entering liquid temperature.
Performance based upon 208/60/1 voltage
VP-C-203 D
Model D
VP-C-303
VP-C-403 D
R-410A Refrigerant
Estimated
Ship Weight
Heating based upon 2 row coil, 70°F DB entering air temperature,
105°F entering liquid temperature. Heating
based upon 2 row coil, 70°F DB entering air temperature, 105°F entering liq
VP-C-503 D
Model based
Compressor
Voltage
Charge
Fan Motor Performance
Cabinet
/ Chassis
Performance
upon 208/60/1 voltage
VP-C-203 D
based
upon 208/60/1 voltage
VP-C-603 D
(oz.)
(lbs)
VP-C-303 D
VP-C-803 D
VP-C-403 D
VP-C-203 D
Rotary
23
PSC, EC
153 / 88
VP-C-1003 D
VP-C-503 D
VP-C-303 D
Rotary
24
PSC, EC
153 / 90
VP-C-1203 D
VP-C-603 D
VP-C-403 D
Rotary
26.3
PSC, EC
153 / 93
VP-C-803 D
VP-C-503 D
Rotary
208-230/60/1
34
PSC, EC
173 / 135
VP-C-1003 D
VP-C-603 D
Rotary
265/60/1
34
PSC, EC
173 / 136
VP-C-1203 D
VP-C-803 D
Rotary
36
EC
173 / 148
VP-C-1003 D
Scroll
46
EC
192 / 183
VP-C-1203 D
Scroll
51
EC
192 / 194
-10WHALEN CO. - P.O. Box 1390 - Easton, Maryland 21601 - Tel. (410) 822-9200 - Fax (410) 822-8926 - www.whalencompany.com
Notes:
Take the Next Step
To learn more about how The Whalen Company can help
you save time and money on your next project, contact
your local Whalen representative, call 410-822-9200 to
speak with one of our specialists, or e-mail your request to
sales@whalencompany.com.
Additional technical resources, including dimensional
drawings and Revit models, are available on our website at
www.whalencompany.com or at http://seek.autodesk.com.
Behind every unit that carries the Whalen name is a singularity
of purpose: the engineering and manufacturing of products
that improve the quality of life for our customers.
Our long-term commitment to this endeavor assures you
of systems that are distinctive in concept, performance,
reliability and value.
The number of industry “firsts” from Whalen is impressive.
They include:
• The industry’s first vertical stack valveless fan coils
• The first vertical stack heat pump offering
• The first removable chassis closet-type heat pumps
• The first AHRI-listed water-cooled air conditioning
units with hydronic heat
Your Whalen Representative:
Let us put Whalen innovation to work for you, too. Find out
how our approach to your project will deliver a “perfect fit”
solution – and make your life easier.
P.O. Box 1390 • Easton, MD 21601 USA
Tel. 410-822-9200 • Fax: 410-822-8926
www.whalencompany.com
Closetline, Closetpack, Whisperline and Whisperpack are trademarks of The Whalen Company. ©2015 The Whalen Company. All rights reserved.
CAS-WA-WL-ALL-rev. 0615