Technologies for the light of tomorrow.

advertisement
Technologies for the
light of tomorrow.
Components for LED applications
• Electroniccontrolgear
• LEDmodules
• LEDlightengine
Components for fluorescent lamps
• Electroniccontrolgear
www.BAGelectronics.com
BAG electronics | Product Catalogue 2014
1
2
Product Catalogue 2014 | BAG electronics
22
Shop
30
Outdoor
38
Industry
Industry
Shop
14
Outdoor
Office & Commercial
Office & Commercial
Applications
Components for fluorescent lamps
Electroniccontrolgear
Accessories
100
158
BAG electronics | Product Catalogue 2014
Components for fluorescent lamps
Electroniccontrolgear
LEDmodules
LEDlightengine
40
Accessories
Components for LED applications
Components for LED applications
Products
3
BAG: Your expert partner for electronic ballasts for LED
components, fluorescent lamps and high pressure discharge
lamps. Energy efficiency combined with quality and
operational safety. If it’s a matter of individual concepts
for special requirements, then customers aroand the world
place their trust in control gear and solutions from BAG,
developed and constructed to achieve high efficiency, high
safety and high functionality.
4
Product Catalogue 2014 | BAG electronics
Intelligent and efficient
solutions for the light of tomorrow.
Your partner for lighting electronics.
Lightisourworld:BAGelectronicsisesteemedacrosstheworldasa
premierpartnertothelightingindustry.Wecreateinnovativesolutionsandnewconceptsforgreaterefficiencyandlowerenergyconsumption.Ourcorporategroupdevelops,manufacturesandmarkets
highqualityelectroniccomponentsforlightingapplications–with
maximumqualityandreliabilityincluded.
Discovertomorrow‘slightingsolutionstoday:energyefficiency
combinedwithqualityandoperationalsafety.Individualconceptsfor
specialneeds:customersaroandtheglobeplacetheirtrustinour
solutionswhenitcomestosuchobjectives.Developedandconstructedtoachievehighefficiency,highsafetyandhighfunctionality.
ThismakesBAGoneofthetopaddressesworldwideforlighting
electronics.
Our platform strategy
– for your benefit
Wepursueaconsistentplatformstrategyinallour
productgroups.
Youradvantage:anoptimumprocessefficiencywithuniformhousingsizesandidenticalwiringforeachproduct
group.Smartfeaturesandaslimdesignprovideflexibility
foryourlightingdesign.
Efficient solutions for the light of tomorrow.
Components for LED applications
BAGoffersawidespectrumofelectronic
controlgearfortheoperationofLED
moduleswiththeZITARESproductfamily,
andperformancefeaturesareprimarily
aimedattheuseoftheECGinprofessional
generallightingapplicationswithwhitelight.
Thedifferingversionsofferoptimalsolutions
forawidearrayofapplicationsforexamplein
theoffice,school,industryandshopsectors.
LED modules
ASTARESrepresentsanassortmentofLED
modulesdesignedforawidediversityof
lightingtasks.Hereapplicationswithmainly
linearaswellasplanelightsourceswere
takenintoaccount.
LED light engine
WithNEXARES,BAGpresentsalightengine
whereLEDmoduleandelectroniccontrol
unitarecombinedonaPCB,anall-in-one
solution.Thedesignhasalsofocusedon
minimumconstructionheight.Withaheight
ofonly8mmandwithoutthenecessityofan
additionalcontrolgearhavingtobeinstalled
intheluminaire,NEXARESenablesmaximum
flexibilityforluminairedesign.
Page52
Page94
Page98
BAG electronics | Product Catalogue 2014
5
Future-fit from tradition.
Our history is the basis
for perfect solutions
Future-fitfromtradition:BAGhasalwaysbeenabletoidentifyfuture
technologicalsectorsatanearlystageanddevelopexactsolutions
forthese.Ourcompanyrootsreachbacktotheyear1909.Andmore
than40yearsagothefirstignitersandballastsweremanufacturedin
TurgiinSwitzerland.Thissignifiedthestartofoursuccessstoryasa
partnerforthelightingindustry.
It‘stheexpertiseandexperienceofourapproximately3,000employeesaroandtheworldthatmakesthedifference.Inaddition
toheadquartersinArnsberg,Germany,wealsomaintainsalesand
developmentlocationsinEuropeandAsiaaswellasstate-of-the-art
productionsitesinChina,IndiaandonthePhilippines.andourproductsaremarketedaroandtheworldinover50countries.
1909
1967
1968
1972
1981
1998/99
The roots of the
company
BAG Turgi initiates
production of
igniters and ballasts
BAG Turgi launches
the first hot restrike
igniters to the
market
Superimposedpulse igniters
replace thyristorcontrolled igniters
The first electronic
control gear are
presented
A production site
is founded on the
Philippines
Withinventionofthe
highpressuresodium
vapourlampbyGE,BAG
startsproductionofa
supplyunitconsistingofa
thyristor-controlledigniter
andinductiveballast.
ThecompanyofOsram
releasesthefirstthyristorcontrolledsuperimposedpulseignitersfromBAG
foroperating400Whigh
pressuresodiumvapour
lamps.Furtherigniter
approvalsfollow.
Thefirstsuperimposedpulseigniterswith
bi-metalstarterunder
thenameofSM6replace
thyristor-controlled
ignitersasswitching
elements.
Weshowelectroniccontrolgearforthefirsttime
attheHanovertradefair.
Thefirstforeignmanufacturinglocationis
foundednearManilaon
thePhilippines.
TheSwissBroncegussAG
(BAG)isfoundedinTurgi/
Switzerland.
6
Product Catalogue 2014 | BAG electronics
Expansion in China
Aproductionsiteisfounded
inZhuhai.
Our Locations
3
1
2
4
6
7
8
9
5
1
Arnsberg, Germany
4
Marketing&sales,research&
development,production,
administration
2
5
Sales,research&development
3
Espelkamp, Germany
Sales
6
Pune, India
Beijing, China
Hong Kong, China
Marketing,sales
10
Zhuhai, China
Production,sales,research&development
9
Sales
7
Production,sales,research&development
London, United Kingdom
8
Sales
Mailand, Italy
10
Manila, Philippines
Production,sales
Guangzhou, China
Sales,research&development
2000
2002
2005
2009/10
2012
2013/14
The advent of
Multi-Lamp
Technology
Company takeover
and relocation
of BAG Turgi to
Arnsberg
Market launch of
Zirius hot restrike
igniters
BAG electronics
takes over HÜCO
Lightronic from
Espelkamp
BAG foands the
LEDcycle
ZITARES intelligent
revolutionises LED
control
Aneweracomesabout
withproductionofthe
world‘sfirstelectronic
ballastsforfluorescent
lampswithmulti-lamp
technology.
BAGelectronicsGmbH
isfoundedin2002with
itslocationatArnsberg,
Germany.Thefurther
expansionalsocoversall
activitiesintheareasof
production,development,
salesmanagement,
marketing,procurement
andlogistics.
Inthehotre-ignition
sectorthenewZIRIUS
generationofferscompletelyelectronicignition
deviceswithintelligent
ignitionmanagement
systemstoachieveseveral
useradvantages.
Thepremiumquality
productsbecomeapartof
theBAGexpandedproduct
portfolio,andHÜCO
employeesstrengthenthe
organisation.Rightontime
forLight+Building2010:
thedual-brandstrategy
isreplacedwiththenew
corporatedesign,and
HÜCOLightronicisalso
calledBAG
Byfoandinganown
businesssector,allactivitiesconcerningthefuture
technologyofLEDare
bandledtotheadvantage
ofcustomers.
Everythingfromasingle
source:BAGprovidesa
completesolutionwith
thereliableandhigh-
performanceLEDECG
fromtheZITARESfamily
andtheZITARES360
software.ZITARESintelligentmakesLEDcontrol
technologymoreflexible
thaneverbefore.
BAG electronics | Product Catalogue 2014
7
Quality without compromise
The satisfaction of our customers is always our focus.
Qualityknowsnocompromises:thesatisfactionofourcustomersis
alwaysofprimaryimportanceforus.Matureandoptimisedquality
managementbasedonISOcertificationguaranteesthequalityand
reliabilitytobeexpectedofBAGproducts.Forus,thequalitycontrol
ofeachindividualproductisasnaturalasthecarefulselectionof
suppliersandcontinuousmonitoringofallquality-relevantprocesses.
Eachproductisfundamentallyinspectedpriortodispatch.Testing
meansaredevelopedinGermanyaccordingtothecurrentstateof
technologyandthusensureahomogeneouslevelofqualityacrossall
locations,onaglobalscale.
Efficiency and precision
Expect more from us.
Theobjectiveacknowledgementofthecomprehensivequalitymanagementsystemisreflectedinmanyinternationalqualityattributes
thatdistinguishourproducts.AccreditationofourdevelopmentlaboratoryincompliancewiththeTestDataAcceptanceProgram(TDAP)of
theVDEaffordsadditionalsecurity.
Qualityandprecisionarethepreconditionsfordependablelighting
solutions–simplyexpectmoreofus.Moreservice,individualsolutionsandindividualtechnicalcustomersupport.
BAGISO9001:2008-Certificate
8
Product Catalogue 2014 | BAG electronics
BAGISO9001:2008IQNet
BAG 5 years warranty – Full security completely
without registration.
WithBAGproductsyoualwaystakethedecisionforinnovativetechnology,constantlyhighmanufacturingstandardsandabove-average
operationaldurations.Ourbrandrepresentsqualitythatyoucan
permanentlyrelyon,combinedwithmaximumstandardsofquality
andefficientprocesses.
Thislevelofreliabilitybenefitsyouintheformofhigheconomic
efficiencyandahighlevelofoperationalsafety.Inordertobestmeet
yourexpectationswithregardtoqualityandperfection,weoffer
youabove-averagewarrantytimes,simpleandsafe,andcompletely
withoutregistrationbeforehand.
BAG electronics | Product Catalogue 2014
9
LEDcycle
Your requirements in focus
Your requirements in focus
Reliable,safeandenergy-efficientsystems
aredemandedrangingfromluminairedesign
tooptimallymatchedelectronics.Thisis
whyBAGhasbandledallcomponentsand
developedtheLEDcycle:focusedexpertise
andexperiencepreciselymatchedtoyour
requirements.TheLEDcycleoffersyoumuch
morethanjusttherightECGorLEDmodule–
youreceivenotonlyproductsbutsolutions,
andmatchedentirelytoyourneeds.
10
Product Catalogue 2014 | BAG electronics
Technical Roadmap
Competence 1
Rapidavailabilitycoordinatedpreciselyto
specificdemands–theBAGplatformsmeet
theneedsofluminairemanufacturersacross
awidespectrum.ThecombinationofelectroniccontrolgearandLEDmoduleshave
beendesignedforspecificapplicationsand
permanentlysimplifyproductionplanning
andlogisticsforluminaireproducers.Inthe
dynamicLEDsectorit‘sallaboutshortinnovationcycles,andtheplatformsarecreated
preciselywiththisinmindastheyenable
rapidityofproductdevelopmentandalways
offeryouthelateststateoflightingelectronics.Afurtherbenefit:thankstotheBAG
platformstrategy,luminairemanufacturers
candesignmodularluminairesystems,can
simplifyprocurementandmakeproduction
significantlymoreflexible.TheBAGisactively
workingwiththeindustrialconsortium
Zhaga,thisdealswiththestandardization
ofLEDcomponents.
Product Portfolio
Competence 2
ECG,modulesandlightengines:all
componentsoftheBAGLEDsystemare
optimallymatchedtoeachotherandoffer
maximumflexibilityforcustomer-specific
demandsandawidespectrumofapplications,rangingfromshopsandofficesto
administrationbuildingsandindustrialhalls.
Luminaireproducersalwaysfindtheright
solutionwiththecomplete,modularBAG
portfolio.Professionallightingimplemented
preciselyaccordingtoaims.
Whether for offices, shops, industrial halls
or public buildings, LED technology has
reductionised the most varied of application
in lighting technology as quickly and
sustainably as never before.
Competencies
Competence 3
OfcourseBAGdedicateditselfatanearly
stagetoLEDtechnology,andtheresultis
tried-and-proven,future-fitsolutionsfor
lightingelectronics.ThisappliestoLEDECGs
aswellasLEDmodulesandlightengines
thatinparticularmeetthedemandsof
thermalmanagement,opticsandmechanics.
Nolessimportantissuitablesoftware.This
enablesspecialapplicationstobeoptimised
andproductdevelopmenttobeaccelerated.
Systemsforthesimulationofelectric,optic
andthermalinfluencesareapermanentpart
oftheBAGdevelopmentprocess,asis
practicaltesting.
Youradvantage:highreliabilityandquality
thatyoucandependon,evenanderextreme
conditionsofuse.
Partnerships
Competence 4
Hand-in-handtoachievethetarget:
strategicpartnershipsformthebasisforrapid
andsuccessfuldevelopmentoffuturesafe
andpremiumqualityproducts.BAGis
organisedonaglobalscaleandatthe
sametimeclosetocustomers,tightlyrooted
andorientedtothefuture.Thisappliesnot
justtotechnologiesbutalsotosuppliers,
researchanddevelopment,production
locations,andalsotothetightand
consultation-orientedpartnershipwith
customers.
Process
Competence 5
Thankstodecadesofexperienceindevelopmentandmanufacturing,BAGisapartner
torenownedluminairemanufacturersasa
supplieroflightingelectronics,andisestablishedacrosstheworld.Demandsintheera
ofLEDcontinuallyincreaseandchange,and
therequirementsofresearchanddevelopmentarestringent.ThisiswhyBAGfocuses
allexpertiseandresourcesintoanewunit
thatsupportsyouevenmorequickly,more
individuallyandwithmoreservicequality
acrossthecompleteprocesschain.Thenew
LEDunitconcentratesexclusivelyonthis
futuremarket,isgloballyorganisedand
unitesourdecadesofexistingexpertise
andexperience.
BAG electronics | Product Catalogue 2014
11
Precisely the right solution for any luminaire
From LED continuous lines to downlights.
Linear
Plane
ECG
ECG
ZITARES CC 2-Channel SELV dimmable
CCD270-70LS-01/220-240/DALI
ZITARES CC 2-Channel SELV dimmable
66
ZITARES CC 1-Channel SELV dimmable
CCD1100-50FR-20/200-240/DALI
62
62
NCD135-70FX-20/220-240/DALI
88
Modules
ASTARES linear 1100lm/280 mm
ASTARES linear 1100lm/280 mm
94
ASTARES linear 2200lm/560 mm
LMC-AS-200-840-LP-20/L56W4
CCD1100-50FR-20/200-240/DALI
ZITARES NC 1-Channel non-SELV dimmable
68
Modules
LMC-AS-110-840-LP-20/L28W4
66
ZITARES CC 1-Channel SELV dimmable
ZITARES NC 1-Channel non-SELV dimmable
NCD135-70FX-20/220-240/DALI
CCD270-70LS-01/220-240/DALI
LMC-AS-110-830-LP-20/L28W4
94
ASTARES linear 2200lm/560 mm
94
LMC-AS-200-840-LP-20/L56W4
94
Light-Engine
NEXARES All-in-One 1300lm
LMM-NE-110-840-RP-02
98
NEXARES All-in-One 2000lm
LMM-NE-200-840-RP-02
12
Product Catalogue 2014 | BAG electronics
98
Our product range
BAGoffersyouamodern,continuouslyexpandedportfolioofproducts andenergy-efficient.Ourassortmentfocusesoncontrolgear
andsolutionsforlightingelectronicsthataresafe,qualitative,reliable forfluorescentlampsandfuture-fitsolutionswithLED.
Downlight
Spot
ECG
ECG
ZITARES UC 1-Channel SELV non-dimmable
UCS170-20LI-11/100-240
ZITARES UC 1-Channel SELV non-dimmable
54
ZITARES CC 1-Channel SELV dimmable
CCD170-35QS-01/220-240/DALI
54
ZITARES CC 1-Channel SELV dimmable
58
ZITARES CC 2-Channel SELV dimmable
CCD270-70QS-01/220-240/DALI
UCS170-35LI-11/100-240
CCD170-35QS-01/220-240/DALI
58
ZITARES CC 2-Channel SELV dimmable
70
CCD270-70QS-01/220-240/DALI
70
Light-Engine
NEXARES All-in-One 1300lm
LMM-NE-110-840-RP-02
98
NEXARES All-in-One 2000lm
LMM-NE-200-840-RP-02
98
BAG electronics | Product Catalogue 2014
13
Office & Commercial
Modern worlds of work
Light for offices and communication
Transparency,communicationandflexibility.
Modernworkingenvironmentshavecauseda
newwayofthinkingintermsofarchitectureand
buildingtechnology,andthisincludescustomdesignedlightingsolutions.Goodlightplanning
createspositiveroomatmospheresthatimprove
well-beingandthusalsotheperformance
capabilityofemployees.LEDtechnologyhas
alreadydecisivelyconqueredtheworldofoffices,
butthefactorofsustainabilityisjustasimportant
–energyefficiencyandlowlevelsofmaintenance
gohand-in-hand.Efficientelectronicsformodern
officelightingcomesfromBAG.
14
Product Catalogue 2014 | BAG electronics
Office & Commercial
BAG electronics | Product Catalogue 2014
15
Office & Commercial
16
Product Catalogue 2014 | BAG electronics
Office & Commercial
LED modules for offices and
public areas
→Lowmaintenanceandoperationcostsduetolonglifetimeand
veryhighefficiencyofmodules
→Highqualitylightforextendentvisualcomfort
→Idealforlinearandplanarluminaires
Components for LED applications
ASTARES linear
›Page94
BAG electronics | Product Catalogue 2014
17
Office & Commercial
18
Product Catalogue 2014 | BAG electronics
Office & Commercial
ZITARES intelligent is the first LED ECG that individually adapts to
your luminaires and projects – precisely as you need.
Withconstantluminousfluxovertheoperatingdurationtoindependentandindividualcontrolofthetwooutputchannels,theECGcanbe
flexiblyusedinawidevarietyofluminaires,rangingfromlineartofreestandingluminaires,settingyourprojectintherightlight.Thecoreof
theintelligentECGisamicrocontrollerthatoptimisesyourluminairesin
combinationwithoptionalsensorsforawidevarietyofapplications.All
parametersareconfiguredwiththeZITARES360software.Thisintegrates
seamlesslyintoyourdevelopmentandproductionprocess.
Inadditiontomanyfunctionselectionoptions,ZITARESalsofeatures
intelligentsafetyforthefuture.Thankstosmartinterfacecommunication,
ECGdatacanbeprogrammedandreadoutwithhighspeed,andyour
luminairescanalsobeequippedwithupdates.
Components for LED applications
ZITARES intelligent
›Page74
BAG electronics | Product Catalogue 2014
19
Office & Commercial
20
Product Catalogue 2014 | BAG electronics
Office & Commercial
Compact and with combined
DALI / Push-DIM interface
Control gear for FL
BCD TC DALI
TWINGLE DIM –
→FullflexibilityandreductionofECGvarietyduetoMulti-power
technologycombinedwithtwinglefuncionality
→Optimalmaintenanceefficiencyandreliabilitybasedona
max.lifetimeof100.000operatinghourstogetherwith
BAG5yearswarranty
→ComfortableandeasycontrolviapushbuttonorDALI
→BestavailableenergyefficiencyclassEEI=A2BAT
›Page152
BAG electronics | Product Catalogue 2014
21
Series productivity
Light for industry and technology
Industry
22
Industrialapplicationsplaceparticulardemands
onlighting:maximumreliability,functionality,
flexiblemodifications,expandabilityandalso
highenergyefficiency.Therightlighthasa
majorinfluenceonproductivityandfriction-free
processes,andqualitystandardsarehigh.
Youcanbesureofmakingtherightchoicein
thisapplicationsectorwithBAGsolutionsfor
lightingelectronics.
Product Catalogue 2014 | BAG electronics
Industry
BAG electronics | Product Catalogue 2014
23
Industry
24
Product Catalogue 2014 | BAG electronics
Industry
Efficient LED modules with linear
design.
→Lowmaintenanceandoperationcostsduetolonglifetime
andhighefficiencyofmodules
→Optimizedthermalmanagementforuseinroughenvironments
→Cascadabledesignallowslumenpackagesofmorethan20,000lm
suppliedbyacentralECG
->Idealforcontinuouslineandwater-proofluminaires
Components for LED applications
ASTARES linear
›Page94
BAG electronics | Product Catalogue 2014
25
Industry
26
Product Catalogue 2014 | BAG electronics
Industry
Optimum energy efficiency
→FullflexibilityandreductionofECGvarietyduetoT5Multi-Lamp
technologycombinedwithtwinglefuncionality
→Optimalmaintenanceefficiencyandreliabilitybasedonamax.
lifetimeof100.000operatinghours
→Suitableforuseintemperature-criticalindustryapplications
Control gear for FL
MLS EVO II für T5 Lampen
›Page112
BAG electronics | Product Catalogue 2014
27
Industry
28
Product Catalogue 2014 | BAG electronics
Industry
Electronic control gear units
(LED)
Components for LED applications
ZITARES NCS
2nd Generation
→Adjustableoutputcurrentforflexibleandfuture-proof
operationofLEDmodules
→LonglifetimeandexcellentreliabilitywithBAG5yearwarranty
→Bestavailableenergyefficiencyupto94%andoptimizedcircuit
designforlowapplicationcosts
›Page86
BAG electronics | Product Catalogue 2014
29
Shopping as an experience
Light for shops
Shop
30
Transformingshoppingintoanexperience:
Retaillandscapesplannedindetailcommunicate
withcustomersonanemotionallevelandalso
haveasales-promotingeffect.LEDlighting
solutionsareindispensableatthePOSinorder
tooptimallypresentproductsbothindividually
andwithhighenergyefficiency.BAGisyour
supplierforhigh-performanceanddurable
electronicsforretaillighting.
Product Catalogue 2014 | BAG electronics
Shop
BAG electronics | Product Catalogue 2014
31
Shop
32
Product Catalogue 2014 | BAG electronics
Shop
LED-modules
→Lowmaintenanceandoperationcostsduetolong
lifetimeandhighefficiencyofmodules
→Highqualitylightforextendentvisualcomfort
→Idealforcontinuouslineluminaires
Components for LED applications
ASTARES linear
2nd Generation
›Page94
BAG electronics | Product Catalogue 2014
33
Shop
34
Product Catalogue 2014 | BAG electronics
Shop
Compact LED-ECG for
independent use.
→PowerandoutputcurrentrangeoptimizedforLEDpointlightsources
→SELVoutputvoltageallowsasimplifiedandsafetyluminaire
construction
→IndependentinstallationofECGforfiligreeluminairedesign
Components for LED applications
ZITARES UCS
›Page54
BAG electronics | Product Catalogue 2014
35
Shop
36
Product Catalogue 2014 | BAG electronics
Shop
Control gear for FL
BCS TC TWINGLE
High performance in a
compact construction.
→FullflexibilityandreductionofECGvarietyduetoMulti-power
technologycombinedwithtwinglefuncionality
→Optimalmaintenanceefficiencyandreliabilitybasedona
max.lifetimeof100.000operatinghourstogetherwith
BAG5yearswarranty
→BestavailableenergyefficiencyclassEEI=A2BAT
›Page126
BAG electronics | Product Catalogue 2014
37
Sustainable and safe
Light for outdoors
Outdoor
38
Lightgeneratesatmosphereandalsogivesa
senseofsafety,especiallyonroads,townplazas
andinlargesportsarenas.Lightingsolutionsfor
outdoorapplicationsmustmainlybereliablein
allsituations.BAGsuppliescustom-designed
lightingelectronics,andconstructedforthe
completespectrumofapplicationsectors.
Modernlightalsocutscostsandprotectsour
naturalresources,andwithpubliclightingthe
potentialforsavingisenormous.
Product Catalogue 2014 | BAG electronics
Outdoor
BAG electronics | Product Catalogue 2014
39
Outdoor
40
Product Catalogue 2014 | BAG electronics
Outdoor
Efficient LED modules with linear
design.
→Lowmaintenanceandoperationcostsduetolonglifetimeand
highefficiencyofmodules
→Optimizedthermalmanagementforuseinroughenvironments
→Non-SELVoperationforcostoptimizedsystemdesign
→Idealforandwaterproofluminaires
Components for LED applications
ASTARES linear
›Page94
BAG electronics | Product Catalogue 2014
41
Outdoor
42
Product Catalogue 2014 | BAG electronics
Outdoor
Outdoor LED control gear units.
→Adjustableoutputcurrentforflexibleandfuture-proofoperation
ofLEDmodules
→Longlifetimeandexcellentreliabilitytogetherwith
BAG5yearwarranty
→Highenergyefficiencyandmultiplecontrolfunctionalities
fordemand-actuatedstreetlightingapplications
→LEDprotectgivesafullsystemprotectionagainstovervoltages
Components for LED applications
ZITARES OCD
›Page92
BAG electronics | Product Catalogue 2014
43
Outdoor
44
Product Catalogue 2014 | BAG electronics
Outdoor
→FullflexibilityandreductionofECGvarietyduetoT5&T8
Multi-Powertechnology
→Optimalmaintenanceefficiencyandreliabilitybasedona
max.lifetimeof100.000operatinghourstogetherwith
BAG5yearswarranty
→BestavailableenergyefficiencyclassEEI=A2BAT
→Suitableforuseintemperature-criticaloutdoorapplications
Control gear for FL
BCS Primus for T5 /
T8 lamps
›Page118
BAG electronics | Product Catalogue 2014
45
46
Product Catalogue 2014 | BAG electronics
Components for LED applications
Electronic control units
ZITARES ED
ZITARES UCS
ZITARES CCS
ZITARES CCD
ZITARES CCS 2nd Generation
ZITARES CCD 2nd Generation
ZITARES CCS
ZITARES CCD
ZITARES CCS
ZITARES CCD
ZITARES CCS 2nd Generation
ZITARES ICD
ZITARES CCS
ZITARES CCD
ZITARES NCS
ZITARES LCS
ZITARES NCS 2nd Generation
ZITARES NCD 2nd Generation
ZITARES OCS
1-Channel | non-dimmable | SELV| compact ................... 52
1-Channel | non-dimmable | SELV | independent ............ 54
1-Channel | non-dimmable | SELV | compact .................. 56
1-Channel | dimmable | SELV | compact ............................58
1-Channel | non-dimmable | SELV | linear........................60
1-Channel | dimmable | SELV | linear .................................. 62
2-Channel | non-dimmable r | SELV| linear ....................... 64
2-Channel | dimmable | SELV| linear .................................. 66
2-Channel | non-dimmable | SELV | compact..................68
2-Channel | dimmable | SELV| compact ............................. 70
2-Channel | dimmable | SELV | linear...................................72
2-Channel | dimmable | SELV | linear...................................74
4-Channel | non-dimmable | SELV | linear ........................76
4-Channel | dimmable | SELV | linear ................................ 78
1-Channel | non-dimmable | non-SELV | PCB ................. 82
1-Channel | non-dimmable | non-SELV | linear .............. 84
1-Channel | non-dimmable | non-SELV | linear ..............86
1-Channel | dimmable | non-SELV | linear .........................88
1-Channel | non-dimmable | non-SELV | outdoor ..........90
ZITARES OCD
1-Channel | dimmable | non-SELV | outdoor..................... 92
ASTARES linear 2nd Generation
ASTARES plane 2nd Generation
LED-Module | high performance | linear ............................ 94
LED-Module | high performance | plane ............................ 96
LED Light Engine
NEXARES 2nd Generation
LED Light-Engines | All-in-one | round ..............................98
BAG electronics | Product Catalogue 2014
Components for LED applications
LED Module
47
Productfinder - Selection table
Electronic control gear units
LED Components
48
Model
Order
Number
Output
[mA]
SELV ≤
60V
Power
[W]
Supply Voltage
Dim
lxwxh
[mm]
Page
ED 10W/350mA HMC
10096231
1 x 350
∙
10
220 ... 240 V; 0/50…60 Hz
-
80 x 40 x 22
52
UCS135-20LI-11/100-240
10092212
1 x 350
∙
20
100 ... 240 V; 50…60 Hz
-
140 x 45 x 25
54
UCS150-20LI-11/100-240
10106905
1 x 500
∙
20
100 ... 240 V; 50…60 Hz
-
140 x 45 x 25
54
UCS170-20LI-11/100-240
10092215
1 x 700
∙
20
100 ... 240 V; 50…60 Hz
-
140 x 45 x 25
54
UCS170-35LI-11/100-240
10092218
1 x 700
∙
35
100 ... 240 V; 50…60 Hz
-
140 x 45 x 31
54
UCS1105-50LI-11/100-240/ AUX
10112613
1 x 1050
∙
50
100 ... 240 V; 50…60 Hz
-
153 x 49 x 33
54
CCS135-18QS-01/220-240
10078982
1 x 350
∙
18
220 ... 240 V; 0/50…60 Hz
-
123 x 79 x 22
56
CCS170-35QS-01/220-240
10078983
1 x 700
∙
35
220 ... 240 V; 0/50…60 Hz
-
123 x 79 x 22
56
CCD135-18QS-01/220-240/1–10V
10078978
1 x 350
∙
18
220 ... 240 V; 0/50…60 Hz
1-10 V
123 x 79 x 22
58
CCD135-18QS-01/220-240/DALI
10078979
1 x 350
∙
18
220 ... 240 V; 0/50…60 Hz
DALI / Push-Dim
123 x 79 x 22
58
CCD170-35QS-01/220-240/1–10V
10078980
1 x 700
∙
35
220 ... 240 V; 0/50…60 Hz
1-10 V
123 x 79 x 22
58
CCD170-35QS-01/220-240/DALI
10078981
1 x 700
∙
35
220 ... 240 V; 0/50…60 Hz
DALI / Push-Dim
123 x 79 x 22
58
CCS1100-50FR-20/200-240
10116434
1 x 500 … 1000
∙
50
220 ... 240 V; 0/50…60 Hz
-
360 x 30 x 21
60
CCS1150-50FR-20/200-240
10116440
1 x 1000 …
1500
∙
50
220 ... 240 V; 0/50…60 Hz
-
360 x 30 x 21
60
CCD1100-50FR-20/200-240/DALI
10116437
1 x 500 … 1000
∙
50
220 ... 240 V; 0/50…60 Hz
DALI / Push-Dim
360 x 30 x 21
62
CCD1150-50FR-20/200-240/DALI
10116443
1 x 1000 …
1500
∙
50
220 ... 240 V; 0/50…60 Hz
DALI / Push-Dim
360 x 30 x 21
62
CCS235-35LS-01/220-240
10078966
2 x 350
∙
35
220 ... 240 V; 0/50…60 Hz
-
280 x 39 x 21
64
CCS250-50LS-01/220-240
10105112
2 x 500
∙
50
220 ... 240 V; 0/50…60 Hz
-
280 x 39 x 21
64
CCS270-70LS-01/220-240
10078973
2 x 700
∙
70
220 ... 240 V; 0/50…60 Hz
-
280 x 39 x 21
64
CCS235-35QS-01/220-240
10094454
2 x 350
∙
35
220 ... 240 V; 0/50…60 Hz
-
135 x 75 x 21
68
CCS250-50QS-01/220-240
10098196
2 x 500
∙
50
220 ... 240 V; 0/50…60 Hz
-
135 x 75 x 21
68
CCS270-70QS-01/220-240
10094457
2 x 700
∙
70
220 ... 240 V; 0/50…60 Hz
-
135 x 75 x 21
68
CCD235-35LS-01/220-240/1–10V
10078992
2 x 350
∙
35
220 ... 240 V; 0/50…60 Hz
1-10 V
280 x 39 x 21
66
CCD235-35LS-01/220-240/DALI
10078993
2 x 350
∙
35
220 ... 240 V; 0/50…60 Hz
DALI / Push-Dim
280 x 39 x 21
66
CCD250-50LS-01/220-240/DALI
10105113
2 x 500
∙
50
220 ... 240 V; 0/50…60 Hz
DALI / Push-Dim
280 x 39 x 21
66
CCD270-70LS-01/220-240/1–10V
10078996
2 x 700
∙
70
220 ... 240 V; 0/50…60 Hz
1-10 V
280 x 39 x 21
66
CCD270-70LS-01/220-240/DALI
10078997
2 x 700
∙
70
220 ... 240 V; 0/50…60 Hz
DALI / Push-Dim
280 x 39 x 21
66
CCD235-35QS-01/220-240/DALI
10094460
2 x 350
∙
35
220 ... 240 V; 0/50…60 Hz
DALI / Push-Dim
135 x 75 x 21
70
CCD250-50QS-01/220-240/DALI
10098207
2 x 500
∙
50
220 ... 240 V; 0/50…60 Hz
DALI / Push-Dim
135 x 75 x 21
70
CCD270-70QS-01/220-240/DALI
10094463
2 x 700
∙
70
220 ... 240 V; 0/50…60 Hz
DALI / Push-Dim
135 x 75 x 21
70
Product Catalogue 2014 | BAG electronics
Output
[mA]
SELV ≤
60V
Power
[W]
Supply Voltage
Dim
lxwxh
[mm]
Page
CCD290-60FR-20/200-240/DALI
10116445
2 x 250 … 900
∙
60
220 ... 240 V; 0/50…60 Hz
DALI / Push-Dim
360 x 30 x 21
72
CCD290-100FR-20/200-240/DALI
10116447
2 x 250 … 900
∙
100
220 ... 240 V; 0/50…60 Hz
DALI / Push-Dim
360 x 30 x 21
72
ICD290-60LS-01/220-240/DALI
10105905
2 x 250 … 900
∙
60
220 ... 240 V; 0/50…60 Hz DALI / Push-Dim / DRI 360 x 30 x 21
74
ICD290-100LS-01/220-240/DALI
10105906
2 x 250 … 900
∙
100
220 ... 240 V; 0/50…60 Hz DALI / Push-Dim / DRI 360 x 30 x 21
74
CCS435-70LS-01/220-240
10078975
4 x 350
∙
70
220 ... 240 V; 0/50…60 Hz
-
360 x 39 x 21
76
CCS470-140LS-01/220-240
10078977
4 x 700
∙
140
220 ... 240 V; 0/50…60 Hz
-
360 x 39 x 21
76
CCD435-70LS-01/220-240/1–10V
10079000
4 x 350
∙
70
220 ... 240 V; 0/50…60 Hz
1-10 V
360 x 39 x 21
78
CCD435-70LS-01/220-240/DALI
10079001
4 x 350
∙
70
220 ... 240 V; 0/50…60 Hz
DALI / Push-Dim
360 x 39 x 21
78
CCD470-140LS-01/220-240/1–10V
10079004
4 x 700
∙
140
220 ... 240 V; 0/50…60 Hz
1-10 V
360 x 39 x 21
78
CCD470-140LS-01/220-240/DALI
10079005
4 x 700
∙
140
220 ... 240 V; 0/50…60 Hz
DALI / Push-Dim
360 x 39 x 21
78
NCS170-60LP-01/220-240
10091635
1 x 700
-
60
220 ... 240 V; 0/50…60 Hz
-
255 x 28 x 26
82
LCS135-70FX-01/220-240
10116496
1 x 350
-
70
220 ... 240 V; 50…60 Hz
-
280 x 30 x 21
84
LCS150-70FX-01/220-240
10116500
1 x 500
-
70
220 ... 240 V; 50…60 Hz
-
280 x 30 x 21
84
LCS170-70FX-01/220-240
10116504
1 x 700
-
70
220 ... 240 V; 50…60 Hz
-
280 x 30 x 21
84
NCS135-70FX-20/220-240
10112200
1 x 120 … 350
-
70
220 ... 240 V; 0/50…60 Hz
-
280 x 30 x 21
86
NCS180-100FX-20/220-240
10112201
1 x 350 … 800
-
100
220 ... 240 V; 0/50…60 Hz
-
280 x 30 x 21
86
NCD135-70FX-20/220-240/DALI
10116488
1 x 120 … 350
-
70
220 ... 240 V; 0/50…60 Hz
DALI / Push-Dim
280 x 30 x 21
88
NCD180-100FX-20/220-240/DALI
10116492
1 x 350 … 800
-
100
220 ... 240 V; 0/50…60 Hz
DALI / Push-Dim
280 x 30 x 21
88
OCS170-40LS-01 / 220-240
10111551
1 x 500 / 600
/ 700
∙
40
220 ... 240 V; 50…60 Hz
-
184 x 59 x 36
90
OCS170-80LS-01 / 220-240
10111552
1 x 500 / 600
/ 700
∙
80
220 ... 240 V; 50…60 Hz
-
184 x 59 x 36
90
OCS170-150LS-01 / 220-240
10111553
1 x 500 / 600
/ 700
-
150
220 ... 240 V; 50…60 Hz
-
235 x 59 x 39
90
OCS1140-80LS-01 / 220-240
10116782
1 x 1050 / 1200
/ 1400
∙
80
220 ... 240 V; 50…60 Hz
-
184 x 59 x 36
90
OCS1140-150LS-01 / 220-240
10116783
1 x 1050 / 1200
/ 1400
-
150
220 ... 240 V; 50…60 Hz
-
235 x 59 x 39
90
OCD180-40LS-01 / 220-240 / DALI
10111554
1 x 350 … 750
∙
40
220 ... 240 V; 50…60 Hz
DALI / CP / geoDIM
184 x 59 x 39
92
OCD180-80LS-01 / 220-240 / DALI
10111555
1 x 350 … 750
∙
80
220 ... 240 V; 50…60 Hz
DALI / CP / geoDIM
184 x 59 x 39
92
OCD180-160LS-01 / 220-240 / DALI
10111556
1 x 350 … 750
-
150
220 ... 240 V; 50…60 Hz
DALI / CP / geoDIM
235 x 59 x 39
92
BAG electronics | Product Catalogue 2014
Productfinder - Selction LED EVG
Order
Number
LED Components
Model
49
Productfinder - Selection table
LED Modules
Model
Order
Number
LMC-AS-110-830-LP-20 / L28W4
10107824
Light output
[lm]
Colour
code
1050
1100
10107825
2100
10107826
2200
10107827
4
350 mA / 12 VDC
8
700 mA /12 VDC
4
350 mA / 12 VDC
16
700 mA /24 VDC
8
350 mA / 24 VDC
16
700 mA /24 VDC
8
350 mA / 24 VDC
840
1100
Productfinder - Selection LED Modules
lxwxh
[mm]
Page
280 x 40 x 6
94
280 x 40 x 6
94
560 x 40 x 6
94
560 x 40 x 6
94
LMC-AS-120-840-PP-20
10112594
1250
830
8
700 mA /12 VDC
259 x 250 x 6
96
LMC-AS-120-830-PP-20
10112595
1200
840
8
700 mA /12 VDC
259 x 250 x 6
96
LMM-NE-110-830-RP-02
10108580
1300
830
10
220 ... 240 VAC
Ø 190 x 8
98
LMM-NE-110-840-RP-02
10108581
1300
840
10
220 ... 240 VAC
Ø 190 x 8
98
LMM-NE-200-830-RP-02
10108582
2000
830
16
220 ... 240 VAC
Ø 240 x 8
98
LMM-NE-200-840-RP-02
10108583
2000
840
15
220 ... 240 VAC
Ø 240 x 8
98
LED Components
50
700 mA /12 VDC
830
1050
LMC-AS-200-840-LP-20 / L56W4
8
840
550
LMC-AS-200-830-LP-20 / L56W4
Supply
830
550
LMC-AS-110-840-LP-20 / L28W4
Power
Product Catalogue 2014 | BAG electronics
BAG electronics | Product Catalogue 2014
51
ZITARES ED
Non-dimmable constant current ECG
for LED modules (SELV)
with single channel output
Electronic control gears | ZITARES ED
Product information
• Non-dimmable 1-channel ECG for constant current
operation of LED modules
• SELV equiv. output voltage ≤ 60 VDC
• Efficiency of up to 90 % (100 % load)
• Soft start and low output current ripple
LED Components
• ECG extensively protected against abnormal operating
conditions at the output e.g. short-circuit, open circuit
or overload
• Suitable for direct current operation and application in
combination with central battery installations
• Compact housing for maximum flexibility in luminaire
design
• Certified as thermally protected device
• Conformance with international regulations, regarding
safety and operation, electromagnetic compatibility and
immunity to interference
• Nominal service life: 50,000 h with failure rate ≤ 10 %
and operation at tc=tc,max
Industry
    
Office & Commercial
    
Outdoor
    
Shop
    
Technical data
Conformity
EN 61347-1
Mains voltage supply
Rated voltage range
220 ... 240 [V]
EN 61347-2-13
Rated frequency
0 / 50 ... 60 [Hz]
EN 62384
Admissible continuous voltage range
(AC)
198 - 264 [VAC]
EN 55015
Admissible continuous voltage range
(DC)
198 ... 278 [VAC]
Total harmonic distortion (THD)
15 %, at 100 % load
EN 61547
Switch-off of the LEDs at overvoltage
appr. 320 V
Overvoltage protection (time)
350 V / 2 h
Output data
Constant current
fixed
Output current tolerance
+/- 5 %
Max. ripple output current
+/- 10%
Output voltage limitation
60 VDC; SELV equiv.
Galvanic separation to mains input
yes, test voltage 3.75 kV
Max. starting time
0.5 s
Dimming interfaces;
depending on ECG model
None
Degree of protection
Degree of protection
Product Catalogue 2014 | BAG electronics
IEC 60068-2-27
Behaviour at mains overvoltage
Interfaces and dimming operation
52
IEC 60068-2-6
IP20
Designations
Operating data
Designation
Material number
No. of channels
ED 10W/350mA HMC
10096231
1
Output current
Output voltage
Max. total output
power
Input current
mA
VDC
W
A
350
5 ... 30
10
0.12
Power factor
ECG efficiency
%
0.5
85
- All specifications with 230 VAC nominal operation and 100 % load
Dimensions | weights | temperatures
Short designation
ED 10W / 350mA
Length X
Width Y
Height Z
Hole spacing XM
(length direction)
Weight
Ambient temperature ta
Housing temperature
tc,max
mm
mm
mm
mm
kg
°C
°C
80
40
22
70
0.045
-20 ... 50
85
Y
Z
Case drawing
Electronic control gears | ZITARES ED
XM
X
Wiring diagrams
Connection of ECG input and output side
+
LED Components
CH1
BAG electronics | Product Catalogue 2014
53
ZITARES UCS
Non-dimmable constant current ECG
for LED modules (SELV)
with single channel output
Electronic control gears | ZITARES UCS
Product information
• Non-dimmable 1-channel ECG for constant current
operation of LED modules
• SELV output voltage ≤ 60 VDC
• High efficiency of up to 90 % (100 % load)
• Wide range input voltage 100 – 240 VAC
LED Components
• For use in combination with luminaires of protection
class I and II as independent device
• ECG extensively protected against abnormal operating
conditions at the output e.g. short-circuit, open circuit
or overload
Industry
    
Office & Commercial
    
Outdoor
    
Shop
    
Technical data
Conformity
EN 61347-1
Mains voltage supply
Rated voltage range
100 ... 240 [V]
EN 61347-2-13
Rated frequency
50 ... 60 [Hz]
EN 62384
Admissible continuous voltage range
(AC)
90 - 264 [VAC]
EN 55015
Total harmonic distortion (THD)
15 %, at 100 % load
EN 61547
Output data
Constant current
fixed
Output current tolerance
+/- 10 %
• Certified as thermally protected device
Max. ripple output current
+/- 15 %
• Conformance with international regulations, regarding
safety and operation, electromagnetic compatibility and
immunity to interference
Output voltage limitation
60 VDC; SELV
Galvanic separation to mains input
yes, test voltage 3.75 kV
Max. starting time
0.5 s
• Nominal service life: 45,000 h with failure rate ≤ 10 %
and operation at tc=tc,max
Interfaces and dimming operation
Dimming interfaces;
depending on ECG model
None
Degree of protection
Degree of protection
54
Product Catalogue 2014 | BAG electronics
IP20
Designations
Operating data
Designation
Material number
No. of channels
UCS135-20LI-11/100-240
10092212
1
UCS170-20LI-11/100-240
10092215
1
Output current
Output voltage
Max. total output
power
Input current
Power factor
ECG efficiency
mA
VDC
W
A
350
28 ... 58
20
0.22
0.9
85
700
14 ... 29
20
0.22
0.9
85
%
UCS170-35LI-11/100-240
10092218
1
700
25 ... 51
35
0.38
0.9
85
UCS150-20LI-11/100-240
10106905
1
500
27 ... 40
20
0.22
0.9
85
1
1050
36 ... 48
50
0.62
0.9
85
Width Y
Height Z
Hole spacing XM
(length direction)
Hole spacing YM
(width direction)
Weight
Ambient temperature ta
Housing temperature tc,max
UCS1105-50LI-11/100-240/ 10112613
AUX
- All specifications with 230 VAC nominal operation and 100 % load
Dimensions | weights | temperatures
Short designation
Length X
mm
mm
mm
mm
mm
kg
°C
°C
UCS135-20LI-11...
140
45
25
133
37
0.130
-25 ... 50
80
UCS170-20LI-11...
140
45
25
133
37
0.130
-25 ... 50
80
UCS170-35LI-11...
140
45
31
133
37
0.155
-25 ... 50
80
UCS150-20LI-11...
140
45
25
133
37
0.130
-25 ... 50
80
UCS1105-50LI-11...
153
49
33
145
41
0.285
-25 ... 50
80
Electronic control gears | ZITARES UCS
Y
YM
Case drawing
XM
X
Wiring diagrams
CH1
LED Components
Connection of ECG input and output side
+
–
BAG electronics | Product Catalogue 2014
55
ZITARES CCS
Non-dimmable constant current ECG
for LED modules (SELV)
with single channel output
Electronic control gears | ZITARES CCS
Product information
• Non-dimmable 1-channel ECG for constant current
operation of LED modules
• SELV equiv. output voltage ≤ 60 VDC
• Very high efficiency of up to 90 % (100 % load)
• Soft start and low output current ripple
• For use in luminaires of protection class I
LED Components
• ECG extensively protected against abnormal operating
conditions at the output e.g. short-circuit, open circuit
or overload
• Suitable for direct current operation and application in
combination with central battery installations
• Compact housing for maximum flexibility in luminaire
design
• Identical dimensions for dimmable and non-dimmable
versions
• Certified as thermally protected device
• Conformance with international regulations, regarding
safety and operation, electromagnetic compatibility and
immunity to interference
• Nominal service life: 50,000 h with failure rate ≤ 10 %
and operation at tc=tc,max
Industry
    
Office & Commercial
    
Outdoor
    
Shop
    
Technical data
Conformity
EN 61347-1
Mains voltage supply
Rated voltage range
220 ... 240 [V]
EN 61347-2-13
Rated frequency
0 / 50 ... 60 [Hz]
EN 62384
Admissible continuous voltage range
(AC)
198 - 264 [V]
EN 61547
Admissible continuous voltage range
(DC)
198 ... 278 [V]
Max. leakage current
0.5 mA
Total harmonic distortion (THD)
10 %, at 100 % load
EN 55015
Switch-off of the LEDs at overvoltage
appr. 320 VAC
Overvoltage protection (time)
350 VAC / 2 h
Output data
Designations
Constant current
fixed
Output current tolerance
+/- 5%
Max. ripple output current
+/- 10%
Output voltage limitation
60 VDC; SELV equiv.
Galvanic separation to mains input
yes, test voltage 3.75 kV
Max. starting time
0.5 s
Dimming interfaces;
depending on ECG model
None
Degree of protection
Degree of protection
Product Catalogue 2014 | BAG electronics
IEC 60068-2-27
Behaviour at mains overvoltage
Interfaces and dimming operation
56
IEC 60068-2-6
IP20
Operating data
Designation
Material number
No. of channels
Output current
Output voltage
Max. total
output power
Input current
CCS135-18QS-01/220-240
10078982
1
CCS170-35QS-01/220-240
10078983
Power factor
ECG efficiency
mA
VDC
W
A
350
10 ... 50
18
0.19
0.95
88
1
700
10 ... 50
35
0.38
0.95
90
Width Y
Height Z
Hole spacing XM
(length direction)
Hole spacing YM
(width direction)
Weight
Ambient temperature ta
Housing temperature tc,max
%
- All specifications with 230 VAC nominal operation and 100 % load
Dimensions | weights | temperatures
Short designation
Length X
mm
mm
mm
mm
mm
kg
°C
°C
CCS1...18QS-01...
123
79
22
111
67
0.170
-25 ... 55
75
CCS1...35QS-01...
123
79
22
111
67
0.170
-25 ... 50
75
Electronic control gears | ZITARES CCS
YM
Y
Z
Case drawing
XM
X
Wiring diagrams
Connection of ECG input and output side
PE
L
N
+
–
LED Components
CH1
more ECG
BAG electronics | Product Catalogue 2014
57
ZITARES CCD
Dimmable constant current ECG
for LED modules (SELV)
with single channel output
Electronic control gears | ZITARES CCD
Product information
• Dimmable 1-channel ECG for constant current operation
of LED modules
• SELV equiv. output voltage ≤ 60 VDC
• Very high efficiency of up to 90 % (100 % load)
• Soft start and low output current ripple
• For use in luminaires of protection class I
LED Components
• ECG extensively protected against abnormal operating
conditions at the output e.g. short-circuit, open circuit
or overload
• Suitable for direct current operation and application in
combination with central battery installations
• Overvoltage protection of the DALI and 1–10 V
interfaces up to 264 VAC
• Push-Dim function of DALI interface: switching and
dimming via push-button
• Settable recovery function: automatic switch-on after
mains failure
• Dimming range: 1 ... 100 % luminous flux
• PWM dimming with 500 Hz for flicker-free light and
prevention of stroboscopic effects
• Compact housing for maximum flexibility in luminaire
design
• Identical dimensions for dimmable and
non-dimmable versions
    
Office & Commercial
    
Outdoor
    
Shop
    
Technical data
Conformity
EN 61347-1
Mains voltage supply
Rated voltage range
220 ... 240 [V]
EN 61347-2-13
Rated frequency
0 / 50 ... 60 [Hz]
EN 62384
Admissible continuous voltage range
(AC)
198 - 264 [V]
EN 61547
Admissible continuous voltage range
(DC)
198 ... 278 [V]
Max. leakage current
0.5 mA
Total harmonic distortion (THD)
10 %, at 100 % load
EN 55015
Switch-off of the LEDs at overvoltage
appr. 320 VAC
Overvoltage protection (time)
350 VAC / 2 h
Output data
IEC 60068-2-6
IEC 60068-2-27
Designations
Constant current
fixed
Output current tolerance
+/- 5%
Max. ripple output current
+/- 10%
Output voltage limitation
60 VDC; SELV equiv.
Galvanic separation to mains input
yes, test voltage 3.75 kV
Max. starting time
0.5 s
Interfaces and dimming operation
Dimming interfaces;
depending on ECG model
1-10V, DALI, Push-Dim
Dimming range
• Conformance with international regulations, regarding
safety and operation, electromagnetic compatibility and
immunity to interference
Dimming technology
PWM
Max. Stand-by power (DALI & Push-Dim)
0.3 W
Max. number of ECGs (Push-Dim)
25
Max. control current (1-10V)
0.6 mA
1...100%
Degree of protection
Degree of protection
Product Catalogue 2014 | BAG electronics
EN 62386-102
Behaviour at mains overvoltage
• Certified as thermally protected device
• Nominal service life: 50,000 h with failure rate ≤ 10 %
and operation at tc=tc,max
58
Industry
IP20
Operating data
Designation
Material number
No. of channels
Output current
Output voltage
Max. total output
power
Input current
CCD135-18QS-01/
220-240/1-10V
10078978
1
CCD135-18QS-01/
220-240/DALI
10078979
CCD170-35QS-01/
220-240/1-10V
CCD170-35QS-01/
220-240/DALI
Power factor
ECG efficiency
mA
VDC
W
A
350
10 ... 50
18
0.19
0.95
88
1
350
10 ... 50
18
0.19
0.95
88
10078980
1
700
10 ... 50
35
0.38
0.95
90
10078981
1
700
10 ... 50
35
0.38
0.95
90
Hole spacing XM
(length direction)
Hole spacing YM
(width direction)
Weight
Ambient temperature ta
Housing temperature tc,max
%
- All specifications with 230 VAC nominal operation and 100 % load
- Power output in undimmed operation should not go below 20 % of the maximum permissible value
Short designation
Length X
Width Y
Height Z
mm
mm
mm
mm
mm
kg
°C
°C
CCD1...18QS-01... / 1-10V
123
79
22
111
67
0.175
-25 ... 55
75
CCD1...18QS-01... / DALI
123
79
22
111
67
0.175
-25 ... 55
75
CCD1...35QS-01... / 1-10V
123
79
22
111
67
0.175
-25 ... 50
75
CCD1...35QS-01... / DALI
123
79
22
111
67
0.175
-25 ... 50
75
YM
Y
Z
Case drawing
XM
X
Wiring diagrams
PE
CH1
L
3 - Connection of ECG input and output side side for 1 - 10V control
N
+
–
DA
DA
DA
DA
more ECGs
PE
CH1
+
–
1-10 V
+
–
1-10 V
+
–
L
N
LED Components
1 - Connection
of ECG input and output side for DALI control
Electronic control gears | ZITARES CCD
Dimensions | weights | temperatures
more ECGs
2 - Connection
of ECG input and output side for control via push-button
PE
CH1
L
N
+
–
Push-DIM DA
DA
L
more ECGs
BAG electronics | Product Catalogue 2014
59
ZITARES CCS 2nd Generation
Non-dimmable constant current ECG
for LED modules (SELV)
with adjustable single channel output
Electronic control gears | ZITARES CCS 2nd Generation
Product information
• Non-dimmable 1-channel ECG for constant current
operation of LED modules
• Adjustable output currents by plug-in of resistors
(LEDset)
• SELV equiv. output voltage ≤ 60 VDC
• Very high efficiency of up to 90 % (100 % load)
LED Components
• Soft start and low output current ripple
• For use in luminaires of protection class I
• ECG extensively protected against abnormal operating
conditions at the output e.g. short-circuit, open circuit
or overload
• Suitable for direct current operation and application
in combination with central battery installations
• Compact housing for maximum flexibility in luminaire
design
• Identical dimensions for dimmable and
non-dimmable versions
• Certified as thermally protected device
• Conformance with international regulations, regarding
safety and operation, electromagnetic compatibility and
immunity to interference
• Nominal service life: 50,000 h with failure rate ≤ 10 %
and operation at tc=tc,max
Industry
    
Office & Commercial
    
Outdoor
    
Shop
    
Technical data
Conformity
EN 61347-1
Mains voltage supply
Rated voltage range
220 ... 240 [V]
EN 61347-2-13
Rated frequency
0 / 50 ... 60 [Hz]
EN 62384
Admissible continuous voltage range
(AC)
198 - 264 [V]
EN 61547
Admissible continuous voltage range
(DC)
198 ... 278 [V]
Max. leakage current
0.5 mA
Total harmonic distortion (THD)
10 %, at 100 % load
EN 55015
Switch-off of the LEDs at overvoltage
appr. 320 VAC
Overvoltage protection (time)
350 VAC / 2 h
Output data
Designations
Constant current
adjustable
Output current tolerance
+/- 5 %
Max. ripple output current
+/- 10%
Output voltage limitation
60 VDC; SELV equiv.
Galvanic separation to mains input
yes, test voltage 3.75 kV
Max. starting time
0.5 s
Interfaces and dimming operation
Sensor interface
LEDset
None
Degree of protection
Degree of protection
Product Catalogue 2014 | BAG electronics
IEC 60068-2-27
Behaviour at mains overvoltage
Dimming interfaces;
depending on ECG model
60
IEC 60068-2-6
IP20
Operating data
Designation
Material number
No. of channels
Output current
range (default)
Output voltage
Max. total output
power
Input current
Power factor
ECG efficiency
mA
VDC
W
A
CCS1100-50FR-20/220-240 10116434
1
500 ... 1000
(700)
22 ... 55
50
0.27
0.98
%
90
CCS1150-50FR-20/220-240 10116440
1
1000 ... 1500
(1400)
13 ... 50
50
0.27
0.98
90
Width Y
Height Z
Hole spacing XM
(length direction)
Hole spacing ZM
(height direction)
Weight
Ambient temperature ta
Housing temperature tc,max
- All specifications with 230 VAC nominal operation and 100 % load
- Available as of Q3/2014
Dimensions | weights | temperatures
Short designation
Length X
mm
mm
mm
mm
mm
kg
°C
°C
CCS1100-50FR-20...
360
30
21
350
9
0.250
-25 ... 50
75
CCS1150-50FR-20...
360
30
21
350
9
0.250
-25 ... 50
75
Y
Z
ZM
Electronic control gears | ZITARES CCS 2nd Generation
Case drawing
XM
X
Wiring diagrams
1 - Connection
of ECG output side
LEDset
+
–
ohmic
ohmic
resistor
LED Components
CH1: LED
A - Connection
of ECG input side
L
N PE
more ECGs
BAG electronics | Product Catalogue 2014
61
ZITARES CCD 2nd Generation
Dimmable constant current ECG
for LED modules (SELV)
with adjustable single channel output
Electronic control gears | ZITARES CCD 2 Generation
Product information
• Dimmable 1-channel ECG for constant current operation
of LED modules
• Adjustable output currents by plug-in of resistors
(LEDset) or digital programming *
• SELV equiv. output voltage ≤ 60 VDC
• Very high efficiency of up to 90 % (100 % load)
LED Components
• Soft start and low output current ripple
• For use in luminaires of protection class I
• ECG extensively protected against abnormal operating
conditions at the output e.g. short-circuit, open circuit
or overload
• Suitable for direct current operation and application
in combination with central battery installations
• Overvoltage protection of the DALI interface up
to 264 VAC
    
Office & Commercial
    
Outdoor
    
Shop
    
Technical data
Conformity
EN 61347-1
Mains voltage supply
Rated voltage range
220 ... 240 [V]
EN 61347-2-13
Rated frequency
0 / 50 ... 60 [Hz]
EN 62384
Admissible continuous voltage range
(AC)
198 - 264 [V]
EN 61547
Admissible continuous voltage range
(DC)
198 ... 278 [V]
Max. leakage current
0.5 mA
Total harmonic distortion (THD)
10 %, at 100 % load
EN 55015
Switch-off of the LEDs at overvoltage
appr. 320 VAC
Overvoltage protection (time)
350 VAC / 2 h
Output data
• Push-Dim function of DALI interface: switching and
dimming via push-button
Output current tolerance
+/- 5 %
• Settable recovery function: automatic switch-on after
mains failure
Max. ripple output current
+/- 10%
Output voltage limitation
60 VDC; SELV equiv.
Galvanic separation to mains input
yes, test voltage 3.75 kV
Max. starting time
0.5 s
• Compact housing for maximum flexibility in luminaire
design
• Identical dimensions for dimmable and
non-dimmable versions
• Certified as thermally protected device
• Conformance with international regulations, regarding
safety and operation, electromagnetic compatibility and
immunity to interference
• Nominal service life: 50,000 h with failure rate ≤ 10 %
and operation at tc=tc,max
* Programming via software ZITARES 360
Product Catalogue 2014 | BAG electronics
Interfaces and dimming operation
Sensor interface
Dimming interfaces;
depending on ECG model
LEDset
DALI, Push-Dim
Dimming range
1...100%
Dimming technology
PWM
Max. Stand-by power (DALI & Push-Dim)
0.3 W
Max. number of ECGs (Push-Dim)
25
Degree of protection
Degree of protection
EN 62386-207
IEC 60068-2-6
Designations
adjustable
• PWM dimming with 500 Hz for flicker-free light and
prevention of stroboscopic effects
EN 62386-102
IEC 60068-2-27
Behaviour at mains overvoltage
Constant current
• Dimming range: 1 ... 100 % luminous flux
62
Industry
IP20
Operating data
Designation
Material number
No. of channels
CCD1100-50FR-20/
220-240/DALI
10116437
1
CCD1150-50FR-20/
220-240/DALI
10116443
1
Output current
range (default)
Output voltage
Max. total output
power
Input current
Power factor
ECG efficiency
mA
VDC
W
A
500 ... 1000
(700)
22 ... 55
50
0.27
0.98
90
1000 ... 1500
(1400)
13 ... 50
50
0.27
0.98
90
%
- All specifications with 230 VAC nominal operation and 100 % load
- Power output in undimmed operation should not go below 40 % of the maximum permissible value
- Available as of Q4/2014
Dimensions | weights | temperatures
Short designation
Length X
Width Y
Height Z
Hole spacing XM
(length direction)
Hole spacing ZM
(height direction)
Weight
Ambient temperature ta
Housing temperature tc,max
mm
mm
mm
mm
mm
kg
°C
°C
CCD1100-50FR-20... / DALI
360
30
21
350
9
0.260
-25 ... 50
75
CCD1150-50FR-20... / DALI
360
30
21
350
9
0.260
-25 ... 50
75
Y
Z
ZM
Electronic control gears | ZITARES CCD 2nd Generation
Case drawing
XM
X
Wiring diagrams
1 - Connection
of ECG output side
C - Connection ECG-Programming Box for programming
Software ZITARES 360
USB
L
LEDset
DA Programming
Box
DA
+
–
ohmic
ohmic
resistor
LED Components
CH1: LED
N PE
n.c.
DA
DA
A - Connection
of ECG input side for DALI control
PE L
N
DA
DA
n.c.
DA
DA
more ECG
B - Connection of ECG input side for control via push-button L
N PE
n.c.
DA
DA
Push-DIM
more ECG
BAG electronics | Product Catalogue 2014
63
ZITARES CCS
Non-dimmable constant current ECG
for LED modules (SELV)
with 2 channel output
Electronic control gears | ZITARES CCS
Product information
• Non-dimmable 2-channel ECG for constant current
operation of LED modules
• Asymmetrical load for the output channels is admissible
• Selection of additional output currents by means of
parallel connection of the output channels
• SELV equiv. output voltage ≤ 60 VDC
LED Components
• Very high efficiency of up to 91 % (100 % load)
• Soft start and low output current ripple
• For use in luminaires of protection class I
• ECG extensively protected against abnormal operating
conditions at the output e.g. short-circuit, open circuit
or overload
• Suitable for direct current operation and application in
combination with central battery installations
• Compact housing for maximum flexibility in luminaire
design
• Identical dimensions for dimmable and
non-dimmable versions
• Certified as thermally protected device
• Conformance with international regulations, regarding
safety and operation, electromagnetic compatibility and
immunity to interference
• Nominal service life: 50,000 h with failure rate ≤ 10 %
and operation at tc=tc,max
Industry
    
Office & Commercial
    
Outdoor
    
Shop
    
Technical data
Conformity
EN 61347-1
Mains voltage supply
Rated voltage range
220 ... 240 [V]
EN 61347-2-13
Rated frequency
0 / 50 ... 60 [Hz]
EN 62384
Admissible continuous voltage range
(AC)
198 - 264 [V]
EN 61547
Admissible continuous voltage range
(DC)
198 ... 278 [V]
EN 55015
Max. leakage current
0.5 mA
Total harmonic distortion (THD)
10 %, at 100 % load
Behaviour at mains overvoltage
Switch-off of the LEDs at overvoltage
appr. 320 VAC
Overvoltage protection (time)
350 VAC / 2 h
Output data
Designations
Constant current
fixed
Output current tolerance
+/- 5 %
Max. ripple output current
+/- 10%
Output voltage limitation
60 VDC; SELV equiv.
Galvanic separation to mains input
yes, test voltage 3.75 kV
Max. starting time
0.5 s
Interfaces and dimming operation
Dimming interfaces;
depending on ECG model
None
Degree of protection
Degree of protection
64
Product Catalogue 2014 | BAG electronics
IEC 60068-2-27
IP20
Operating data
Designation
Material number
No. of channels
Output current
Output voltage
Max. total output
power
Input current
CCS235-35LS-01/220-240
10078966
2
CCS250-50LS-01/220-240
10105112
CCS270-70LS-01/220-240
10078973
Power factor
ECG efficiency
mA
VDC
W
A
350
10 ... 50
35
0.18
0.98
90
2
500
10 ... 50
50
0.18
0.98
90
2
700
10 ... 50
70
0.18
0.98
91
Hole spacing XM
(length direction)
Hole spacing ZM
(height direction)
Weight
Ambient temperature ta
Housing temperature tc,max
%
- All specifications with 230 VAC nominal operation and 100 % load
- Power output in undimmed operation should not go below 20 % of the maximum permissible value
- Asymmetric load distribution on the outputs is permissible
- Further output currents can be selected via parallel switching of the ECG outputs, see the table „Current selection“
Dimensions | weights | temperatures
Short designation
Length X
Width Y
Height Z
mm
mm
mm
mm
mm
kg
°C
°C
CCS2...35LS-01...
280
39
21
270
9
0.290
-25 ... 55
75
CCS2...50LS-01...
280
39
21
270
9
0.290
-25 ... 50
75
CCS2...70LS-01...
280
39
21
270
9
0.290
-25 ... 50
75
XM
X
1 - Connection of ECG output side
Current selection
Output current
350 mA
+
–
+
CH2: LED
–
CH1: LED
CCS23535LS···
CCS25050LS···
CCS27070LS···
2x
500 mA
2x
700 mA
1x
2x
1.050 mA
1x
1.400 mA
s. Wiring diagrams
1x
1
2
1
2
1
2
2 - Connection of ECG output side
LED Components
Wiring diagrams
Electronic control gears | ZITARES CCS
Y
Z
ZM
Case drawing
+
–
+
CH2: LED
–
CH1: LED
A - Connection of ECG input side
PE L
N
more ECG
BAG electronics | Product Catalogue 2014
65
ZITARES CCD
Dimmable constant current ECG
for LED modules (SELV)
with 2 channel output
Electronic control gears | ZITARES CCD
Product information
• Dimmable 2-channel ECG for constant current operation
of LED modules
• Selection of additional output currents by means of
parallel connection of the output channels
• SELV equiv. output voltage ≤ 60 VDC
• Very high efficiency of up to 91 % (100 % load)
LED Components
• Soft start and low output current ripple
• For use in luminaires of protection class I
• ECG extensively protected against abnormal operating
conditions at the output e.g. short-circuit, open circuit
or overload
• Suitable for direct current operation and application in
combination with central battery installations
• Overvoltage protection of the DALI and
1–10 V interfaces up to 264 VAC
    
Office & Commercial
    
Outdoor
    
Shop
    
Technical data
Conformity
EN 61347-1
Mains voltage supply
Rated voltage range
220 ... 240 [V]
EN 61347-2-13
Rated frequency
0 / 50 ... 60 [Hz]
EN 62384
Admissible continuous voltage range
(AC)
198 - 264 [V]
EN 61547
Admissible continuous voltage range
(DC)
198 ... 278 [V]
Max. leakage current
0.5 mA
Total harmonic distortion (THD)
10 %, at 100 % load
EN 55015
Switch-off of the LEDs at overvoltage
appr. 320 VAC
Overvoltage protection (time)
350 VAC / 2 h
Output data
• Push-Dim function of DALI interface: switching and
dimming via push-button
Output current tolerance
+/- 5 %
• Settable recovery function: automatic switch-on after
mains failure
Max. ripple output current
+/- 10%
Output voltage limitation
60 VDC; SELV equiv.
Galvanic separation to mains input
yes, test voltage 3.75 kV
Max. starting time
0.5 s
• Compact housing for maximum flexibility in luminaire
design
• Identical dimensions for dimmable and
non-dimmable versions
• Certified as thermally protected device
• Conformance with international regulations, regarding
safety and operation, electromagnetic compatibility and
immunity to interference
• Nominal service life: 50,000 h with failure rate ≤ 10 %
and operation at tc=tc,max
Product Catalogue 2014 | BAG electronics
Interfaces and dimming operation
Dimming interfaces;
depending on ECG model
Dimming range
1-10V, DALI, Push-Dim
1...100%
Dimming technology
PWM
Max. Stand-by power (DALI & Push-Dim)
0.3 W
Max. number of ECGs (Push-Dim)
25
Max. control current (1-10V)
0,6 mA
Degree of protection
Degree of protection
EN 62386-207
IEC 60068-2-6
Designations
fixed
• PWM dimming with 500 Hz for flicker-free light and
prevention of stroboscopic effects
EN 62386-102
IEC 60068-2-27
Behaviour at mains overvoltage
Constant current
• Dimming range: 1 ... 100 % luminous flux
66
Industry
IP20
Operating data
Designation
Material number
No. of channels
Output current
Output voltage
Max. total output
power
Input current
CCD235-35LS-01/
220-240/1-10V
10078992
2
CCD235-35LS-01/
220-240/DALI
10078993
CCD250-50LS-01/
220-240/DALI
Power factor
ECG efficiency
mA
VDC
W
A
350
10 ... 50
35
0.18
0.98
90
2
350
10 ... 50
35
0.18
0.98
90
10105113
2
500
10 ... 50
50
0.27
0.98
90
CCD270-70LS-01/
220-240/1-10V
10078996
2
700
10 ... 50
70
0.36
0.98
91
CCD270-70LS-01/
220-240/DALI
10078997
2
700
10 ... 50
70
0.36
0.98
91
Hole spacing XM
(length direction)
Hole spacing ZM
(height direction)
Weight
Ambient temperature ta
Housing temperature tc,max
%
- All specifications with 230 VAC nominal operation and 100 % load
- Power output in undimmed operation should not go below 20 % of the maximum permissible value
- Asymmetric load distribution on the outputs is permissible
- Further output currents can be selected via parallel switching of the ECG outputs, see the table „Current selection“
Short designation
Length X
Height Z
mm
mm
mm
mm
mm
kg
°C
°C
CCD2...35LS-01... / 1-10V
280
39
21
270
9
0.295
-25 ... 55
75
CCD2...35LS-01... / DALI
280
39
21
270
9
0.295
-25 ... 55
75
CCD2...50LS-01... / DALI
280
39
21
270
9
0.295
-25 ... 50
75
CCD2...70LS-01... / 1-10V
280
39
21
270
9
0.295
-25 ... 50
75
CCD2...70LS-01... / DALI
280
39
21
270
9
0.295
-25 ... 50
75
Case drawing
Current selection
CCD23535LS···
Z
ZM
Output current
350 mA
2x
700 mA
2x
1x
1.050 mA
XM
CCD27070LS···
2x
500 mA
Y
CCD25050LS···
1x
1.400 mA
X
1x 1
s. Wiring diagrams
2
1
2
1
2
Wiring diagrams
1 - Connection of ECG output side
B - Connection of ECG input side for control via push-button
PE L
N
+
–
+
CH2: LED
–
CH1: LED
DA
DA
Push-DIM
LED Components
Width Y
Electronic control gears | ZITARES CCD
Dimensions | weights | temperatures
2 - Connection of ECG output side
more ECG
+
–
+
CH2: LED
–
CH1: LED
C - Connection of ECG input side for 1 - 10V control
L
N PE
–
+
–
A - Connection of ECG input side for DALI control
PE L
+
1-10 V
1-10 V
n.c.
N
DA
DA
DA
DA
n.c.
more ECG
more ECG
BAG electronics | Product Catalogue 2014
67
ZITARES CCS
Non-dimmable constant current ECG
for LED modules (SELV)
with 2 channel output
Electronic control gears | ZITARES CCS
Product information
• Non-dimmable 2-channel ECG for constant current
operation of LED modules
• Asmmetrical load for the output channels is admissable
• Selection of additional output currents by means of
parallel connection of the output channels
• SELV equiv. output voltage ≤ 60 VDC
LED Components
• Very high efficiency of up to 91 %
• Soft start and low output ripple
• For use in luminairs of protection class I
• Comprehensive protection of the ECG against abnormal
operating conditions at the output, e.g. short circuit,
open circuit, overload
• Suitable for direct current operation and application in
combination with central battery installations
• Housing in compact dimensions for installation in
luminaires
• Identical dimensions for DALI and non-dimmable
versions
• Certified as thermally protected device, e.g. for
application in F-luminaires
• Conformance with international regulations, regarding
safety and operation, electromagnetic compatibility and
immunity to interference
• Nominal service life: 50,000 h with failure rate = 10 %
and operation at tc=tc,max
Product Catalogue 2014 | BAG electronics
    
Office & Commercial
    
Outdoor
    
Shop
    
Technical data
Conformity
EN 61347-1
Mains voltage supply
Rated voltage range
220 ... 240 [V]
EN 61347-2-13
Rated frequency
0 / 50 ... 60 [Hz]
EN 62384
Admissible continuous voltage range
(AC)
198 - 264 [V]
EN 61547
Admissible continuous voltage range
(DC)
198 ... 278 [V]
Max. leakage current
0.5 mA
Total harmonic distortion (THD)
10 %, at 100 % load
EN 55015
IEC 60068-2-6
IEC 60068-2-27
Behaviour at mains overvoltage
Switch-off of the LEDs at overvoltage
appr. 320 VAC
Overvoltage protection (time)
350 VAC / 2 h
Output data
Designations
Constant current
fixed
Output current tolerance
+/- 5 %
Max. ripple output current
+/- 10%
Output voltage limitation
60 VDC; SELV equiv.
Galvanic separation to mains input
yes, test voltage 3.75 kV
Max. starting time
0.5 s
Interfaces and dimming operation
Dimming interfaces;
depending on ECG model
None
Degree of protection
Degree of protection
68
Industry
IP20
Operating data
Designation
Material number
No. of channels
Output current
Output voltage
Max. total output
power
Input current
CCS235-35QS-01/220-240
10094454
2
CCS250-50QS-01/220-240
10098196
CCS270-70QS-01/220-240
10094457
Power factor
ECG efficiency
mA
VDC
W
A
350
10 ... 50
35
0.18
0.98
90
2
500
10 ... 50
50
0.27
0.98
90
2
700
10 ... 50
70
0.36
0.98
91
Hole spacing XM
(length direction)
Hole spacing YM
(width direction)
Weight
Ambient temperature ta
Housing temperature tc,max
%
- All specifications with 230 VAC nominal operation and 100 % load
- Power output in undimmed operation should not go below 20 % of the maximum permissible value
- Asymmetric load distribution on the outputs is permissible
- Further output currents can be selected via parallel switching of the ECG outputs, see the table „Current selection“
Dimensions | weights | temperatures
Short designation
Length X
Width Y
Height Z
mm
mm
mm
mm
mm
kg
°C
°C
CCS2...35QS-01...
135
75
21
124
64
0.250
-25 ... 55
75
CCS2...50QS-01...
135
75
21
124
64
0.250
-25 ... 50
75
CCS2...70QS-01...
135
75
21
124
64
0.250
-25 ... 50
75
Current selection
1 - Connection
of ECG output side
Output current
350 mA
CCS23535QS···
CCS25050QS···
2x
500 mA
2x
700 mA
1x
2x
1.050 mA
+
–
+
CH2: LED
–
CH1: LED
CCS27070QS···
1x
1.400 mA
s. Wiring diagrams
1x
1
2
1
2
1
2
2 - Connection
of ECG output side
LED Components
Wiring diagrams
Electronic control gears | ZITARES CCS
Case drawing
+
–
+
CH2: LED
–
CH1: LED
A - Connection
of ECG input side
PE
+
–
+
CH2: LED
–
CH1: LED
L
N
ohmic
resistor
more ECG
BAG electronics | Product Catalogue 2014
69
ZITARES CCD
Dimmable constant current ECG
for LED modules (SELV)
with 2 channel output
Electronic control gears | ZITARES CCD
Product information
• Dimmable 2-channel ECG for constant current operation
of LED modules
• Asmmetrical load for the output channels is admissable
• Selection of additional output currents by means of
parallel connection of the output channels
• SELV equiv. output voltage ≤ 60 VDC
LED Components
• Very high efficiency of up to 91 %
• Soft start and low output ripple
• For use in luminairs of protection class I
• Comprehensive protection of the ECG against abnormal
operating conditions at the output, e.g. short circuit,
open circuit, overload
• Suitable for direct current operation and application in
combination with central battery installations
• Overvoltage protection of the DALI interface up to
264 VAC
• Push-Dim function for DALI versions: dimming and
switching via push-button, with memory function
• Dimming range: 1 ... 100 % luminous flux
• PWM dimming with 500 Hz for flicker-free light and
prevention of stoboscopic effects
• Housing in compact dimensions for installation in
luminaires
• Identical dimensions for DALI and non-dimmable
versions
• Certified as thermally protected device, e.g. for
application in F-luminaires
• Conformance with international regulations, regarding
safety and operation, electromagnetic compatibility and
immunity to interference
• Nominal service life: 50,000 h with failure rate = 10 %
and operation at tc=tc,max
70
Product Catalogue 2014 | BAG electronics
Industry
    
Office & Commercial
    
Outdoor
    
Shop
    
Technical data
Conformity
EN 61347-1
Mains voltage supply
Rated voltage range
220 ... 240 [V]
EN 61347-2-13
Rated frequency
0 / 50 ... 60 [Hz]
EN 62384
Admissible continuous voltage range
(AC)
198 - 264 [V]
EN 61547
Admissible continuous voltage range
(DC)
198 ... 278 [V]
Max. leakage current
0.5 mA
Total harmonic distortion (THD)
10 %, at 100 % load
EN 55015
Switch-off of the LEDs at overvoltage
appr. 320 VAC
Overvoltage protection (time)
350 VAC / 2 h
Output data
fixed
Output current tolerance
+/- 5 %
Max. ripple output current
+/- 10%
Output voltage limitation
60 VDC; SELV equiv.
Galvanic separation to mains input
yes, test voltage 3.75 kV
Max. starting time
0.5 s
Interfaces and dimming operation
DALI, Push-Dim
1...100%
Dimming technology
PWM
Max. Stand-by power (DALI & Push-Dim)
0.3 W
Max. number of ECGs (Push-Dim)
25
Degree of protection
Degree of protection
IEC 60068-2-6
Designations
Constant current
Dimming range
EN 62386-207
IEC 60068-2-27
Behaviour at mains overvoltage
Dimming interfaces;
depending on ECG model
EN 62386-102
IP20
Operating data
Designation
Material number
No. of channels
Output current
Output voltage
Max. total output
power
Input current
CCD235-35QS-01/
220-240/DALI
10094460
2
CCD250-0QS-01/
220-240/DALI
10098207
CCD270-70QS-01/
220-240/DALI
10094463
Power factor
ECG efficiency
mA
VDC
W
A
350
10 ... 50
35
0.18
0.98
90
2
500
10 ... 50
50
0.27
0.98
90
2
700
10 ... 50
70
0.36
0.98
91
Hole spacing XM
(length direction)
Hole spacing YM
(width direction)
Weight
Ambient temperature ta
Housing temperature tc,max
%
- All specifications with 230 VAC nominal operation and 100 % load
- Power output in undimmed operation should not go below 20 % of the maximum permissible value
- Asymmetric load distribution on the outputs is permissible
- Further output currents can be selected via parallel switching of the ECG outputs, see the table „Current selection“
Dimensions | weights | temperatures
Short designation
Length X
mm
mm
mm
mm
mm
kg
°C
°C
CCD2...35QS-01... / DALI
135
75
21
124
64
0.255
-25 ... 55
75
CCD2...50QS-01... / DALI
135
75
21
124
64
0.255
-25 ... 50
75
CCD2...70QS-01... / DALI
135
75
21
124
64
0.255
-25 ... 50
75
Case drawing
Height Z
10094460
Current selection
Z
Output current
350 mA
CCD23535QS···
CCD25050QS···
2x
500 mA
2x
700 mA
1x
2x
1.050 mA
YM
Y
CCD27070QS···
1x
1.400 mA
1x
s. Wiring diagrams
1
2
1
2
1
2
XM
X
Wiring diagrams
B - Connection of ECG input and output side for control via push-button
PE
+
–
+
CH2: LED
–
L
N
LED Components
1 - Connection of ECG output side
Electronic control gears | ZITARES CCD
Width Y
CH1: LED
DA
DA
CH1: LED
CH2: LED
2 - Connection of ECG input and output side
+
–
+
–
more ECG
+
–
+
CH2: LED
–
CH1: LED
A - Connection of ECG input and output side for DALI control
PE
L
N
DA
DA
DA
DA
+
–
+
CH2: LED
–
CH1: LED
more ECG
BAG electronics | Product Catalogue 2014
71
ZITARES CCD 2nd Generation
Dimmable constant current ECG
for LED modules (SELV)
with adjustable 2 channel output
Electronic control gears | ZITARES CCD 2nd Generation
Product information
• Dimmable 2-channel ECG for constant current operation
of LED modules
    
Office & Commercial
    
Outdoor
    
Shop
    
Technical data
Conformity
EN 61347-1
Mains voltage supply
ED
LEDKomponenten
Components
Rated voltage range
220 ... 240 [V]
EN 61347-2-13
Rated frequency
0 / 50 ... 60 [Hz]
EN 62384
• Selection of additional output currents by means of
parallel connection of the output channels
Admissible continuous voltage range
(AC)
198 - 264 [V]
EN 61547
• SELV equiv. output voltage ≤ 60 VDC
Admissible continuous voltage range
(DC)
198 ... 278 [V]
Max. leakage current
0.5 mA
Total harmonic distortion (THD)
10 %, at 100 % load
• Adjustable output currents by plug-in of resistors or
digital programming *
• Very high efficiency of up to 91 % (100 % load)
• Soft start and low output current ripple
• For use in luminaires of protection class I
• ECG extensively protected against abnormal operating
conditions at the output e.g. short-circuit, open circuit
or overload
• Suitable for direct current operation and application in
combination with central battery installations
EN 55015
Switch-off of the LEDs at overvoltage
appr. 320 VAC
Overvoltage protection (time)
350 VAC / 2 h
Output data
• Overvoltage protection of the DALI interface up to
264 VAC
Output current tolerance
+/- 5 %
• Push-Dim function of DALI interface: switching and
dimming via push-button
Max. ripple output current
+/- 10%
Output voltage limitation
60 VDC; SELV equiv.
Galvanic separation to mains input
yes, test voltage 3.75 kV
Max. starting time
0.5 s
• PWM dimming with 500 Hz for flicker-free light and
prevention of stroboscopic effects
• Compact housing for maximum flexibility in luminaire
design
• Certified as thermally protected device
• Conformance with international regulations, regarding
safety and operation, electromagnetic compatibility and
immunity to interference
• Nominal service life: 50,000 h with failure rate ≤ 10 %
and operation at tc=tc,max
* Programming via software ZITARES 360
Product Catalogue 2014 | BAG electronics
Interfaces and dimming operation
Sensor interface
Dimming interfaces;
depending on ECG model
Rset
DALI, Push-Dim
Dimming range
1...100%
Dimming technology
PWM
Max. Stand-by power (DALI & Push-Dim)
0.5 W
Max. number of ECGs (Push-Dim)
25
Degree of protection
Degree of protection
EN 62386-207
IEC 60068-2-6
Designations
adjustable
• Dimming range: 1 ... 100 % luminous flux
EN 62386-102
IEC 60068-2-27
Behaviour at mains overvoltage
Constant current
• Settable recovery function: automatic switch-on after
mains failure
72
Industry
IP20
Operating data
Designation
Material number
No. of channels
CCD290-60FR-20/
220-240/DALI
10116445
2
CCD290-100FR-20/
220-240/DALI
10116447
2
Output current
range (default)
Output voltage
Max. total output
power
Input current
Power factor
ECG efficiency
mA
VDC
W
A
250 ... 900
(700)
10 ... 33
60
0.30
0.98
90
250 ... 900
(700)
25 ... 53
96
0.45
0.98
90
Hole spacing XM
(length direction)
Hole spacing ZM
(height direction)
Weight
Ambient temperature ta
Housing temperature tc,max
%
- All specifications with 230 VAC nominal operation and 100 % load
- Power output in undimmed operation should not go below 40 % of the maximum permissible value
- Asymmetric load distribution on the outputs is permissible
- Further output currents can be selected via parallel switching of the ECG outputs, see the table „Current selection“
- Available as of Q2/2014
Short designation
Length X
Width Y
Height Z
mm
mm
mm
mm
mm
kg
°C
°C
CCD290-60FR-20... / DALI
360
30
21
350
9
0.315
-25 ... 50
75
CCD290-100FR-20... / DALI
360
30
21
350
9
0.315
-25 ... 50
75
Current selection
Case drawing
Z
ZM
Output current
CCD290-60FR···
250 ... 900 mA
2x
Y
500 ... 1800 mA
CCD290-100FR···
2x
1x
s. Wiring diagrams
1
2
1x
1
2
XM
X
Wiring diagrams
1 - Connection of ECG output side
CH1: LED
Rset
PE L
+
N
–
LED
LEDKomponenten
Components
CH2: LED
B - Connection of ECG input and output side for control via push-button
+
DA
–
+
–
DA
ohmic
resistor
Push-DIM
n.c.
2 - Connection of ECG input and output side
CH2: LED
CH1: LED
Rset
+
Electronic control gears | ZITARES CCD 2nd Generation
Dimensions | weights | temperatures
more ECGS
–
+
–
+
–
USB
ohmic
ohmic
resistor
resistor
PE L
A - Connection of ECG input and output side for DALI control
Software ZITARES 360
N
DA Programming
Box
DA
DA
PE L
N
DA
DA
n.c.
DA
DA
DA
n.c.
more ECG
BAG electronics | Product Catalogue 2014
73
ZITARES ICD
Dimmable constant current ECG
for LED modules (SELV)
with programmable 2 channel output
Electronic control gears | ZITARES ICD
Product information
• Dimmable 2 channel ECG for constant current operation
of LED modules
LED Components
• Programmable functions* for modification according to
specific applications
- Individual output current in range 250-900 mA
per channel
- Dimming method: selection between Amplitude,
PWM (500 Hz) and Mixed Mode
- Compensation of LED degradation during operating time
- Selection between 1 and 2 DALI addresses
- Temperature-dependent control of output currents
- Adjustment of output currents by means of resistors
• Detect & React interface: analogue interface for
connecting sensors e.g. for temperature or light
detection
• SELV equiv. output voltage ≤ 60 VDC
    
Office & Commercial
    
Outdoor
    
Shop
    
Technical data
Conformity
EN 61347-1
Mains voltage supply
Rated voltage range
220 ... 240 [V]
EN 61347-2-13
Rated frequency
0 / 50 ... 60 [Hz]
EN 62384
Admissible continuous voltage range
(AC)
198 - 264 [V]
EN 61547
Admissible continuous voltage range
(DC)
198 ... 278 [V]
Max. leakage current
0.5 mA
Total harmonic distortion (THD)
10 %, at 100 % load
EN 55015
Switch-off of the LEDs at overvoltage
appr. 320 VAC
Overvoltage protection (time)
350 VAC / 2 h
Output data
adjustable
• Soft start and low output current ripple
Output current tolerance
+/- 5 %
• For use in luminaires of protection class I
Max. ripple output current
+/- 10%
• ECG extensively protected against abnormal operating
conditions at the output e.g. short-circuit, open circuit
or overload
Output voltage limitation
60 VDC; SELV equiv.
Galvanic separation to mains input
yes, test voltage 3.75
kV
Max. starting time
0.5 s
• Conformance with international regulations, regarding
safety and operation, electromagnetic compatibility and
immunity to interference
• Nominal service life: 50,000 h with failure rate ≤ 10 %
and operation at tc=tc,max
* Programming via software ZITARES 360
Interfaces and dimming operation
Sensor interface
Dimming interfaces;
depending on ECG model
Product Catalogue 2014 | BAG electronics
Detect & React Interface (DRI)
DALI, Push-Dim
Dimming range
1...100%
Dimming technology
PWM
Max. number of ECGs (Push-Dim)
25
Degree of protection
Degree of protection
EN 62386-207
IEC 60068-2-6
Designations
Constant current
• Push-Dim function of DALI interface: switching and
dimming via push-button
EN 62386-102
IEC 60068-2-27
Behaviour at mains overvoltage
• Very high efficiency of up to 90 % (100 % load)
• Suitable for direct current operation and application in
combination with central battery installations
74
Industry
IP20
Operating data
Designation
Material number
No. of channels
ICD290-60LS-01/
220-240/DALI
10105905
2
ICD290-100LS-01/
220-240/DALI
10105906
2
Output current
range (default)
Output voltage
Max. total output
power
Input current
Power factor
ECG efficiency
mA
VDC
W
A
250 ... 900
(700)
10 ... 33
60
0.30
0.98
90
250 ... 900
(700)
25 ... 53
96
0.45
0.98
90
Hole spacing XM
(length direction)
Hole spacing ZM
(height direction)
Weight
Ambient temperature ta
Housing temperature tc,max
%
- All specifications with 230 VAC nominal operation and 100 % load
- Power output in undimmed operation should not go below 40 % of the maximum permissible value
- Asymmetric load distribution on the outputs is permissible
- Further output currents can be selected via parallel switching of the ECG outputs, see the table „Current selection“
Dimensions | weights | temperatures
Short designation
Length X
Width Y
Height Z
mm
mm
mm
mm
mm
kg
°C
°C
ICD290-60LS-01... / DALI
360
30
21
350
9
0.315
-25 ... 50
75
ICD290-100LS-01... / DALI
360
30
21
350
9
0.315
-25 ... 50
75
ZM
Z
Output current
ICD290-60LS···
290-60LS···
ICD290-100LS···
250 ... 900 mA
2x
2x
500 ... 1800 mA
1x
1
2
1 x 1
2
Y
s. Wiring diagrams
XM
X
Wiring diagrams
1 - Connection of ECG output side
CH1: LED
DRI
PE L
+
N
–
+
DA
–
+
–
DA
sensor/
ohmic
resistor
Push-DIM
LED Components
CH2: LED
B - Connection of ECG input side for control via push-button
n.c.
2 - Connection of ECG input and output side
CH2: LED
CH1: LED
DRI
Electronic control gears | ZITARES ICD
Current selection
Case drawing
+
more ECG
–
C - Connection ECG-Programming Box for programming
+
–
+
–
sensor/
ohmic
ohmic
resistor
resistor
A - Connection of ECG input and output side for DALI control
USB
PE L
Software ZITARES 360
N
DA Programming
Box
DA
DA
PE L
N
DA
DA
n.c.
DA
DA
DA
n.c.
more ECG
BAG electronics | Product Catalogue 2014
75
ZITARES CCS
Non-dimmable constant current ECG
for LED modules (SELV)
with 4 channel output
Electronic control gears | ZITARES CCS
Product information
• Non-dimmable 4-channel ECG for constant current
operation of LED modules
• Asymmetrical load for the output channels is admissible
• Selection of additional output currents by means of
parallel connection of the output channels
• SELV equiv. output voltage ≤ 60 VDC
LED Components
• Very high efficiency of up to 93 % (100 % load)
• Soft start and low output current ripple
• For use in luminaires of protection class I
• ECG extensively protected against abnormal operating
conditions at the output e.g. short-circuit, open circuit
or overload
• Suitable for direct current operation and application in
combination with central battery installations
• Compact housing for maximum flexibility in
luminaire design
• Identical dimensions for dimmable and
non-dimmable version
• Certified as thermally protected device
• Conformance with international regulations, regarding
safety and operation, electromagnetic compatibility and
immunity to interference
• Nominal service life: 50,000 h with failure rate ≤ 10 %
and operation at tc=tc,max
Industry
    
Office & Commercial
    
Outdoor
    
Shop
    
Technical data
Conformity
EN 61347-1
Mains voltage supply
Rated voltage range
220 ... 240 [V]
EN 61347-2-13
Rated frequency
0 / 50 ... 60 [Hz]
EN 62384
Admissible continuous voltage range
(AC)
198 - 264 [V]
EN 61547
Admissible continuous voltage range
(DC)
198 ... 278 [V]
Max. leakage current
0.5 mA
Total harmonic distortion (THD)
10 %, at 100 % load
EN 55015
Switch-off of the LEDs at overvoltage
appr. 320 VAC
Overvoltage protection (time)
350 VAC / 2 h
Output data
Designations
Constant current
fixed
Output current tolerance
+/- 5 %
Max. ripple output current
+/- 10%
Output voltage limitation
60 VDC; SELV equiv.
Galvanic separation to mains input
yes, test voltage 3.75 kV
Max. starting time
0.5 s
Interfaces and dimming operation
Dimming interfaces;
depending on ECG model
Degree of protection
Product Catalogue 2014 | BAG electronics
IEC 60068-2-27
Behaviour at mains overvoltage
None
Degree of protection
76
IEC 60068-2-6
IP20
Operating data
Designation
Material number
No. of channels
CCS435-70LS-01/220-240
10078975
4
CCS470-140LS-01/220-240
10078977
4
Output current
Output voltage
Max. total output
power
Input current
Power factor
ECG efficiency
mA
VDC
W
A
350
10 ... 50
70
0.36
0.98
92
700
10 ... 50
140
0.72
0.98
93
Hole spacing XM
(length direction)
Hole spacing ZM
(height direction)
Weight
Ambient temperature ta
Housing temperature tc,max
%
- All specifications with 230 VAC nominal operation and 100 % load
- Power output in undimmed operation should not go below 20 % of the maximum permissible value
- Asymmetric load distribution on the outputs is permissible
- Further output currents can be selected via parallel switching of the ECG outputs, see the table „Current selection“
Dimensions | weights | temperatures
Short designation
Length X
Width Y
Height Z
mm
mm
mm
mm
mm
kg
°C
°C
CCS4...70LS-01...
360
39
21
350
9
0.390
-25 ... 55
80
CCS4...140LS-01...
360
39
21
350
9
0.390
-25 ... 50
80
Current selection
Output current
CCS435-70LS···
350 mA
4x
700 mA
2x
1x
2x
1.050 mA
Y
CCS470-140LS···
1x
4x
1.400 mA
XM
2.100 mA
X
2.800 mA
s. Wiring diagrams
2x
1x
1x
1x
1x
2x
1x
1x
1
2
3
4
5
1
2
3
4
5
Wiring diagrams
5 - Connection of ECG output side
+
–
+
CH2: LED
–
+
CH3: LED
–
+
CH4: LED
–
+
–
+
CH2: LED
–
+
CH3: LED
–
+
CH4: LED
–
CH1: LED
2 - Connection of ECG output side
CH1: LED
LED
LEDKomponenten
Components
1 - Connection of ECG output side
A - Connection of ECG input side
PE L
Electronic control gears | ZITARES CCS
Z
ZM
Case drawing
N
+
–
+
CH2: LED
–
+
CH3: LED
–
+
CH4: LED
–
CH1: LED
3 - Connection of ECG output side
+
–
+
CH2: LED
–
+
CH3: LED
–
+
CH4: LED
–
CH1: LED
more ECG
4 - Connection of ECG output side
+
–
+
CH2: LED
–
+
CH3: LED
–
+
CH4: LED
–
CH1: LED
BAG electronics | Product Catalogue 2014
77
ZITARES CCD
Dimmable constant current ECG
for LED modules (SELV)
with 4 channel output
Electronic control gears | ZITARES CCD
Product information
• Dimmable 4-channel ECG for constant current operation
of LED modules
• Asymmetrical load for the output channels is admissible
• Selection of additional output currents by means of
parallel connection of the output channels
• SELV equiv. output voltage ≤ 60 VDC
LED Components
• Very high efficiency of up to 93 % (100 % load)
• Soft start and low output current ripple
• For use in luminaires of protection class I
• ECG extensively protected against abnormal operating
conditions at the output e.g. short-circuit, open circuit
or overload
• Suitable for direct current operation and application in
combination with central battery installations
• Overvoltage protection of the DALI and
1–10 V interfaces up to 264 VAC
• Push-Dim function of DALI interface: switching and
dimming via push-button
• Settable recovery function: automatic switch-on after
mains failure
• Dimming range: 1 ... 100 % luminous flux
• PWM dimming with 500 Hz for flicker-free light and
prevention of stroboscopic effects
• Compact housing for maximum flexibility in
luminaire design
• Identical dimensions for dimmable and
non-dimmable versions
• Certified as thermally protected device
• Conformance with international regulations, regarding
safety and operation, electromagnetic compatibility and
immunity to interference
• Nominal service life: 50,000 h with failure rate ≤ 10 %
and operation at tc=tc,max
78
Product Catalogue 2014 | BAG electronics
Industry
    
Office & Commercial
    
Outdoor
    
Shop
    
Technical data
Conformity
EN 61347-1
Mains voltage supply
Rated voltage range
220 ... 240 [V]
EN 61347-2-13
Rated frequency
0 / 50 ... 60 [Hz]
EN 62384
Admissible continuous voltage range
(AC)
198 - 264 [V]
EN 61547
Admissible continuous voltage range
(DC)
198 ... 278 [V]
Max. leakage current
0.5 mA
Total harmonic distortion (THD)
10 %, at 100 % load
EN 55015
Switch-off of the LEDs at overvoltage
appr. 320 VAC
Overvoltage protection (time)
350 VAC / 2 h
Output data
fixed
Output current tolerance
+/- 5 %
Max. ripple output current
+/- 10%
Output voltage limitation
60 VDC; SELV equiv.
Galvanic separation to mains input
yes, test voltage 3.75 kV
Max. starting time
0.5 s
Interfaces and dimming operation
1-10V, DALI, Push-Dim
1...100%
Dimming technology
PWM
Max. Stand-by power (DALI & Push-Dim)
0.3 W
Max. number of ECGs (Push-Dim)
25
Max. control current (1-10V)
0.6 mA
Degree of protection
Degree of protection
IEC 60068-2-6
Designations
Constant current
Dimming range
EN 62386-207
IEC 60068-2-27
Behaviour at mains overvoltage
Dimming interfaces;
depending on ECG model
EN 62386-102
IP20
Operating data
Designation
Material number
No. of channels
Output current
Output voltage
Max. total output
power
Input current
CCD435-70LS-01/
220-240/1-10V
10079000
4
CCD435-70LS-01/
220-240/DALI
10079001
CCD470-140LS-01/
220-240/1-10V
CCD470-140LS-01/
220-240/DALI
Power factor
ECG efficiency
mA
VDC
W
A
350
10 ... 50
70
0.36
0.98
92
4
350
10 ... 50
70
0.36
0.98
92
10079004
4
700
10 ... 50
140
0.72
0.98
93
10079005
4
700
10 ... 50
140
0.72
0.98
93
Hole spacing XM
(length direction)
Hole spacing ZM
(height direction)
Weight
Ambient temperature ta
Housing temperature tc,max
%
- All specifications with 230 VAC nominal operation and 100 % load
- Power output in undimmed operation should not go below 20 % of the maximum permissible value
- Asymmetric load distribution on the outputs is permissible
- Further output currents can be selected via parallel switching of the ECG outputs, see the table „Current selection“
Short designation
Length X
Width Y
Height Z
mm
mm
mm
mm
mm
kg
°C
°C
CCD4...70LS-01... / 1-10V
360
39
21
350
9
0.395
-25 ... 55
80
CCD4...70LS-01... / DALI
360
39
21
350
9
0.395
-25 ... 55
80
CCD4...140LS-01... / 1-10V
360
39
21
350
9
0.395
-25 ... 50
80
CCD4...140LS-01... / DALI
360
39
21
350
9
0.395
-25 ... 50
80
Case drawing
Z
ZM
Current selection
Output current
CCD435-70LS···
350 mA
4x
700 mA
2x
1x
2x
1.050 mA
Y
CCD470-140LS···
1x
4x
1.400 mA
XM
2.100 mA
X
2.800 mA
s. Wiring diagrams
2x
1x
1x
1x
1x
2x
1x
1x
1
2
3
4
5
1
2
3
4
5
1 - Connection of ECG output side
+
–
+
CH2: LED
–
+
CH3: LED
–
+
CH4: LED
–
CH1: LED
2 - Connection of ECG output side
+
–
+
CH2: LED
–
+
CH3: LED
–
+
CH4: LED
–
CH1: LED
LED Components
Wiring diagrams
Electronic control gears | ZITARES CCD
Dimensions | weights | temperatures
4 - Connection of ECG output side
+
–
+
CH2: LED
–
+
CH3: LED
–
+
CH4: LED
–
CH1: LED
5 - Connection of ECG output side
+
–
+
CH2: LED
–
+
CH3: LED
–
+
CH4: LED
–
CH1: LED
3 - Connection of ECG output side
+
–
+
CH2: LED
–
+
CH3: LED
–
+
CH4: LED
–
CH1: LED
BAG electronics | Product Catalogue 2014
79
Wiring diagrams
A - Connection of ECG input side for DALI control
PE L
N
PE L
–
DA
+
DA
–
DA
+
n.c.
n.c.
more ECG
B - Connection of ECG input side for control via push-button
N
DA
DA
n.c.
Electronic control gears | ZITARES CCD
more ECG
LED Components
80
N
DA
more ECG
PE L
C - Connection of ECG input side for 1-10 V control
Product Catalogue 2014 | BAG electronics
Push-DIM
1-10 V
1-10 V
BAG electronics | Product Catalogue 2014
81
LED Components
Electronic control gears | ZITARES CCD
ZITARES NCS
Non-dimmable constant current ECG
for LED modules (non-SELV)
with single channel output
Electronic control gears | ZITARES NCS
Product information
• Non-dimmable 1-channel ECG for constant current
operation of LED modules
• Non-SELV output voltage
• Very high efficiency of up to 91 % (100 % load)
• Soft start and low output current ripple
• For use in luminaires of protection class I
LED Components
• ECG extensively protected against abnormal operating
conditions at the output e.g. short-circuit, open circuit
or overload
• Suitable for direct current operation and application in
combination with central battery installations
• Conformance with international regulations, regarding
safety and operation, electromagnetic compatibility and
immunity to interference
• Nominal service life: 50,000 h with failure rate ≤ 10 %
and operation at tc=tc,max
Industry
    
Office & Commercial
    
Outdoor
    
Shop
    
Technical data
Conformity
EN 61347-1
Mains voltage supply
Rated voltage range
220 ... 240 [V]
EN 61347-2-13
Rated frequency
0 / 50 ... 60 [Hz]
EN 62384
Admissible continuous voltage range
(AC)
198 - 264 [VAC]
EN 61547
Admissible continuous voltage range
DC
198 ... 278 [V]
EN 55015
Max. leakage current
0.5 mA
Total harmonic distortion (THD)
10 %, at 100 % load
Behaviour at mains overvoltage
Switch-off of the LEDs at overvoltage
appr. 320 VAC
Overvoltage protection (time)
350 V / 2 h
Output data
Designations
Constant current
fixed
Output current tolerance
+/- 5 %
Max. ripple output current
+/- 25 %
Galvanic separation to mains input
no
Max. starting time
0.5 s
Interfaces and dimming operation
Dimming interfaces;
depending on ECG model
None
Degree of protection
Degree of protection
82
Product Catalogue 2014 | BAG electronics
IEC 60068-2-27
IP00
Operating data
Designation
Material number
No. of channels
NCS170-60LP-01/220-240
10091635
1
Width Y
Output current
Output voltage
Max. total output
power
Input current
Power factor
ECG efficiency
mA
VDC
W
A
700
33 ... 85
60
0.25
0.98
91
Height Z
Hole spacing XM
(length direction)
Hole spacing YM
(width direction)
Weight
Ambient temperature ta
Housing temperature tc,max
%
- All specifications with 230 VAC nominal operation and 100 % load
Dimensions | weights | temperatures
Short designation
Length X
mm
mm
mm
mm
mm
kg
°C
°C
NCS170-60LP-01...
255
28
26
218
21.4
0.110
-25 ... 60
80
Case drawing
Y
YM
XM
Electronic control gears | ZITARES NCS
X
Wiring diagrams
1 - Connection of ECG output side
+
CH1 n.c.
LED Components
–
BAG electronics | Product Catalogue 2014
83
ZITARES LCS
Non-dimmable constant current ECG
for LED modules (non-SELV)
with single channel output
Electronic control gears | ZITARES LCS
Product information
• Non-dimmable 1-channel ECG for constant current
operation of LED modules
• Non-SELV output voltage
• Very high efficiency of up to 93 % (100 % load)
• For use in luminaires of protection class I
LED Components
• ECG extensively protected against abnormal operating
conditions at the output e.g. short-circuit, open circuit
or overload
• Compact housing for maximum flexibility in luminaire
design
• Certified as thermally protected device
• Conformance with international regulations, regarding
safety and operation, electromagnetic compatibility and
immunity to interference
• Nominal service life: 30,000 h with failure rate ≤ 10 %
and operation at tc=tc,max
Industry
    
Office & Commercial
    
Outdoor
    
Shop
    
Technical data
Conformity
EN 61347-1
Mains voltage supply
Rated voltage range
220 ... 240 [V]
EN 61347-2-13
Rated frequency
50 ... 60 [Hz]
EN 62384
Admissible continuous voltage range
(AC)
198 - 264 [VAC]
EN 61547
Admissible continuous voltage range
DC
198 ... 278 [V]
EN 55015
Max. leakage current
0.5 mA
Total harmonic distortion (THD)
15 %, at 100 % load
Behaviour at mains overvoltage
Switch-off of the LEDs at overvoltage
appr. 320 VAC
Overvoltage protection (time)
350 V / 2 h
Output data
Designations
Constant current
fixed
Output current tolerance
+/- 10 %
Max. ripple output current
+/- 20 %
Galvanic separation to mains input
no
Max. starting time
0.5 s
Interfaces and dimming operation
Dimming interfaces;
depending on ECG model
None
Degree of protection
Degree of protection
84
Product Catalogue 2014 | BAG electronics
IEC 60068-2-27
IP20
Operating data
Designation
Material number
No. of channels
Output current
Output voltage
Max. total output
power
Input current
LCS135-70FX-01/220-240
10116496
1
LCS150-70FX-01/220-240
10116500
LCS170-70FX-01/220-240
10116504
Power factor
ECG efficiency
mA
VDC
W
A
350
60 ... 200
70
0.31
0.98
93
1
500
60 ... 140
70
0.31
0.98
93
1
700
60 ... 100
70
0.31
0.98
93
Width Y
Height Z
Hole spacing XM
(length direction)
Hole spacing ZM
(height direction)
Weight
Ambient
temperature ta
Housing
temperature tc,max
%
- All specifications with 230 VAC nominal operation and 100 % load
- Available as of Q3/2014
Dimensions | weights | temperatures
Short designation
Length X
mm
mm
mm
mm
mm
kg
°C
°C
LCS135-70FX-01...
280
30
21
270
9
0.190
-25 ... 50
75
LCS150-70FX-01...
280
30
21
270
9
0.190
-25 ... 50
75
LCS170-70FX-01...
280
30
21
270
9
0.190
-25 ... 50
75
Y
Electronic control gears | ZITARES LCS
Z
Zm
Case drawing
Xm
X
Wiring diagrams
1 1 - Connection
of ECG output side
+
–
LED Components
CH1: LED
A - Connection of ECG input side
L
N PE
more ECG
BAG electronics | Product Catalogue 2014
85
ZITARES NCS 2nd Generation
Non-dimmable constant current ECG
for LED modules (non-SELV)
with adjustable single channel output
Electronic control gears | ZITARES NCS 2nd Generation
Product information
• Non-dimmable 1-channel ECG for constant current
operation of LED modules
• Adjustable output currents by plug-in of resistors
(LEDset)
• Non-SELV output voltage
• Very high efficiency of up to 94 % (100 % load)
LED Components
• Soft start and low output current ripple
• For use in luminaires of protection class I
• ECG extensively protected against abnormal operating
conditions at the output e.g. short-circuit, open circuit
or overload
• Suitable for direct current operation and application in
combination with central battery installations
• Compact housing for maximum flexibility in
luminaire design
• Identical dimensions for dimmable and
non-dimmable versions
• Certified as thermally protected device
• Conformance with international regulations, regarding
safety and operation, electromagnetic compatibility and
immunity to interference
• Nominal service life: 50,000 h with failure rate
≤ 10 % and operation tc=tc,max
Industry
    
Office & Commercial
    
Outdoor
    
Shop
    
Technical data
Conformity
EN 61347-1
Mains voltage supply
Rated voltage range
220 ... 240 [V]
EN 61347-2-13
Rated frequency
0 / 50 ... 60 [Hz]
EN 62384
Admissible continuous voltage range
(AC)
198 - 264 [VAC]
EN 61547
Admissible continuous voltage range
DC
198 ... 278 [V]
Max. leakage current
0.5 mA
Total harmonic distortion (THD)
10 %, at 100 % load
EN 55015
Switch-off of the LEDs at overvoltage
appr. 320 VAC
Overvoltage protection (time)
350 V / 2 h
Output data
Designations
Constant current
adjustable
Output current tolerance
+/- 5 %
Max. ripple output current
+/- 10 %
Galvanic separation to mains input
no
Max. starting time
0.5 s
Interfaces and dimming operation
Sensor interface
Dimming interfaces;
depending on ECG model
Degree of protection
Product Catalogue 2014 | BAG electronics
IEC 60068-2-27
Behaviour at mains overvoltage
LEDset
None
Degree of protection
86
IEC 60068-2-6
IP20
Operating data
Designation
Material number
No. of channels
Output current
range (default)
Output voltage
Max. total output
power
Input current
NCS135-70FX-20/220-240
10112200
1
NCS180-100FX-20/220-240 10112201
Power factor
ECG efficiency
mA
VDC
W
A
120 ... 350
(350)
60 … 190
70
0.31
0.98
94
1
350 ... 800
(700)
30 ... 125
100
0.44
0.98
94
Width Y
Height Z
Hole spacing XM
(length direction)
Hole spacing ZM
(height direction)
Weight
Ambient
temperature ta
Housing temperature tc,max
%
- All specifications with 230 VAC nominal operation and 100 % load
- Available as of Q3/2014
Dimensions | weights | temperatures
Short designation
Length X
mm
mm
mm
mm
mm
kg
°C
°C
NCS135-70FX-20...
280
30
21
270
9
0.200
-25 ... 60
75
NCS180-100FX-20...
280
30
21
270
9
0.250
-25 ... 60
75
Y
Z
Zm
Electronic control gears | ZITARES NCS 2nd Generation
Case drawing
Xm
X
Wiring diagrams
1 - Connection of ECG output side
LEDset
+
–
ohmic
ohmic
resistor
LED Components
CH1: LED
A - Connection of ECG input side
L
N PE
more ECG
BAG electronics | Product Catalogue 2014
87
ZITARES NCD 2nd Generation
Dimmable constant current ECG
for LED modules (non-SELV)
with adjustable single channel output
Electronic control gears | ZITARES NCD 2nd Generation
Product information
• Dimmable 1-channel ECG for constant current operation
of LED modules
• Adjustable output currents by plug-in of resistors or
digital programming *
• Non-SELV output voltage
• Very high efficiency of up to 93 % (100 % load)
LED Components
• Soft start and low output current ripple
• For use in luminaires of protection class I
• ECG extensively protected against abnormal operating
conditions at the output e.g. short-circuit, open circuit
or overload
• Suitable for direct current operation and application in
combination with central battery installations
    
Office & Commercial
    
Outdoor
    
Shop
    
Technical data
Conformity
EN 61347-1
Mains voltage supply
Rated voltage range
220 ... 240 [V]
EN 61347-2-13
Rated frequency
0 / 50 ... 60 [Hz]
EN 62384
Admissible continuous voltage range
(AC)
198 - 264 [VAC]
EN 61547
Max. leakage current
0.5 mA
Total harmonic distortion (THD)
10 %, at 100 % load
EN 55015
Behaviour at mains overvoltage
Switch-off of the LEDs at overvoltage
appr. 320 V
Overvoltage protection (time)
350 V / 2 h
Constant current
adjustable
Output current tolerance
+/- 5 %
• Push-Dim function of DALI interface: switching and
dimming via push-button
Max. ripple output current
+/- 10%
Galvanic separation to mains input
no
Max. starting time
0.5 s
• Dimming range: 1 ... 100 % luminous flux
• PWM dimming with 500 Hz for flicker-free light and
prevention of stroboscopic effects
• Compact housing for maximum flexibility in
luminaire design
• Identical dimensions for dimmable and
non-dimmable versions
• Certified as thermally protected device
• Conformance with international regulations, regarding
safety and operation, electromagnetic compatibility and
immunity to interference
• Nominal service life: 50,000 h with failure rate ≤ 10 %
and operation at tc = tc,max
* Programming via software ZITARES 360
Product Catalogue 2014 | BAG electronics
IEC 60068-2-6
IEC 60068-2-27
EN 62386-102
EN 62386-207
Output data
• Overvoltage protection of the DALI interface up to
264 VAC
• Settable recovery function: automatic switch-on after
mains failure
88
Industry
Interfaces and dimming operation
Sensor interface
Dimming interfaces;
depending on ECG model
LEDset
DALI, Push-Dim
Dimming range
1...100%
Dimming technology
PWM
Max. Stand-by power (DALI & Push-Dim)
0.3 W
Max. number of ECGs (Push-Dim)
25
Degree of protection
Degree of protection
IP20
Designations
Operating data
Designation
Material number
No. of channels
NCD135-70FX-20/
220-240/DALI
10116488
1
NCD180-100FX-20/
220-240/DALI
10116492
1
Output current
range (default)
Output voltage
Max. total output
power
Input current
Power factor
ECG efficiency
mA
VDC
W
A
120 ... 350
(350)
60 … 190
70
0.31
0.98
93
350 ... 800
(700)
30 ... 125
100
0.44
0.98
93
%
- All specifications with 230 VAC nominal operation and 100 % load
- Power output in undimmed operation should not go below 20 % of the maximum permissible value
- Available as of Q4/2014
Dimensions | weights | temperatures
Length X
Width Y
Height Z
Hole spacing XM
(length direction)
Hole spacing ZM
(height direction)
Weight
Ambient temperature ta
Housing temperature tc,max
mm
mm
mm
mm
mm
kg
°C
°C
NCD135-70FX-20... / DALI
280
30
21
270
9
0.260
-25 ... 60
75
NCD180-70FX-20... / DALI
280
30
21
270
9
0.260
-25 ... 60
75
Electronic control gears | ZITARES NCD 2nd Generation
Short designation
Y
Z
Zm
Case drawing
Xm
X
Wiring diagrams
C - Connection ECG-Programming Box for programming
USB
CH1: LED
+
L
–
LEDset
ohmic
ohmic
resistor
A - Connection of ECG input side for DALI control
PE L
Software ZITARES 360
N PE
DA Programming
Box
DA
LED Components
1 - Connection of ECG output side
n.c.
DA
DA
N
DA
DA
n.c.
DA
DA
more ECG
B - Connection of ECG input side for control via push-button
L
N PE
n.c.
DA
DA
Push-DIM
more ECG
BAG electronics | Product Catalogue 2014
89
ZITARES OCS
Non-dimmable constant current ECG
for LED modules for outdoor applications
Electronic control gears | ZITARES OCS
Product information
• 1-channel ECG for constant current operation of
LED modules
• Selectable output current via dip-switch
• Very high efficiency of up to 93 % (100 % load)
• Low ripple and tolerance of the output current for
optimum LED operation
LED Components
• Certified as thermally protected device
• High Surge immunity 6kV sym. and asym.
• No additional surge protection component needed in
the luminaire
• LEDprotect protects the LED driver and the
LED modules
• Double insulated design - only basic insulation of LED
modules in class II luminaires
• Nominal service life: 80,000 h with failure rate ≤ 10 %
and operation at tc = tc,max
Industry
    
Office & Commercial
    
Outdoor
    
Shop
    
Technical data
Conformity
EN 61347-1
Mains voltage supply
Rated voltage range
220 ... 240 [V]
EN 61347-2-13
Rated frequency
50 / 60 Hz
EN 62384
Admissible continuous voltage range
(AC)
198 - 264 [V]
EN 61547
Max. leakage current
0.5 mA
Total harmonic distortion (THD)
10 %, at 100 % load
EN 55015
Behaviour at mains overvoltage
Switch-off of the LEDs at overvoltage
appr. 320 VAC
Overvoltage protection (time)
350 VAC / 48 h
Output current tolerance
+/- 5%
Max. ripple output current
+/- 10%
Max. starting time
0.5 s
Interfaces and dimming operation
None
Degree of protection
Degree of protection
Product Catalogue 2014 | BAG electronics
IEC 60068-2-27
Output data
Dimming interfaces;
depending on ECG model
90
IEC 60068-2-6
IP40
Designations
Operating data
Designation
1
2
Material number
No. of channels
Output current
Output voltage
Max. total output
power
Input current
Power factor
ECG efficiency
mA
VDC
W
A
OCS170-40LS-01/220-240 1 10111551
1
500/600/700
57
40
0.20
0.95
%
85
OCS170-80LS-01/220-240 2 10111552
1
500/600/700
114
80
0.40
0.95
90
OCS170-150LS-01/
220-240 2
10111553
1
500/600/700
214
150
0.75
0.95
93
OCS1140-80LS-01/
220-240 2
10116782
1
1050/1200/
1400
60
80
0.40
0.95
90
OCS1140-150LS-01/
220-240 2
10116783
1
1050/1200/
1400
110
150
0.75
0.95
93
Available as of Q4/2014
Available as of Q3/2014
All specifications with 230 VAC nominal operation and 100 % load
Short designation
Length X
Width Y
Height Z
Hole spacing XM
(length direction)
Weight
Ambient
temperature ta
Housing
temperature tc,max
mm
mm
mm
mm
kg
°C
°C
OCS170-40LS-01...
184
59
36
175
0.640
-30 ... 55
75
OCS170-80LS-01...
184
59
36
175
0.640
-30 ... 55
75
OCS170-150LS-01...
235
59
39
226
0.900
-30 ... 55
75
OCS1140-80LS-01...
184
59
36
175
0.640
-30 ... 55
75
OCS1140-150LS-01...
235
59
39
226
0.900
-30 ... 55
75
LED Components
Y
Z
Case drawing
Electronic control gears | ZITARES OCS
Dimensions | weights | temperatures
Xm
X
Wiring diagrams
Wiring ECG output side with LEDprotect
LEDprotect
CH1
heatsink
+
–
BAG electronics | Product Catalogue 2014
91
ZITARES OCD
Dimmable constant current ECG
for LED modules for outdoor applications
Electronic control gears | ZITARES OCD
Product information
• Dimmable 1-channel ECG for constant current operation
of LED modules
• Programmable output current*
• 3 dimming methods
- geoDIM - independent adaptiv power reduction
- DALI broadcast mode
LED Components
- control phase dimming
• Very high efficiency of up to 93 % (100 % load)
• Low ripple and tolerance of the output current for
optimum LED operation
• Certified as thermally protected device
• High Surge immunity 6kV sym. and asym.
• No additional surge protection component needed in
the luminaire
• LEDprotect protects the LED driver and the
LED modules
• Double insulated design - only basic unsulation of LED
modules in class II luminaires
• Nominal service life: 80,000 h with failure rate ≤ 10 %
and operation at tc = tc,max
* Programming via software ZITARES 360
92
Product Catalogue 2014 | BAG electronics
Industry
    
Office & Commercial
    
Outdoor
    
Shop
    
Technical data
Conformity
EN 61347-1
Mains voltage supply
Rated voltage range
220 ... 240 [V]
EN 61347-2-13
Rated frequency
50 / 60 Hz
EN 62384
Admissible continuous voltage range
(AC)
198 - 264 [V]
EN 55015
Max. leakage current
0.5 mA
Total harmonic distortion (THD)
10 %, at 100 % load
EN 61547
Behaviour at mains overvoltage
Switch-off of the LEDs at overvoltage
appr. 320 VAC
Overvoltage protection (time)
350 VAC / 48 h
EN 62386-102
IEC 60068-2-6
IEC 60068-2-27
Output data
Output current tolerance
+/- 5%
Max. ripple output current
+/- 10%
Interfaces and dimming operation
Dimming interfaces;
depending on ECG model
DALI, geoDIM, Control
phase
Dimming range
40...100%
Dimming technology
Amplitude
Degree of protection
Degree of protection
IP40
Designations
Operating data
1
2
Designation
Material number
No. of channels
Output current
range (default)
Output voltage
Max. total output
power
Input current
OCD175-40LS-01/
220-240/DALI 1
10111554
1
OCD175-80LS-01/
220-240/DALI 2
10111555
OCD175-160LS-01/
220-240/DALI 2
10111556
Power factor
ECG efficiency
mA
VDC
W
A
350 ... 750
(700)
57
40
0.20
0.95
85
1
350 ... 750
(700)
114
80
0.40
0.95
90
1
350 ... 750
(700)
214
160
0.75
0.95
93
%
Available as of Q4/2014
Available as of Q3/2014
All specifications with 230 VAC nominal operation and 100 % load
Dimensions | weights | temperatures
Short designation
Length X
Width Y
Height Z
Hole spacing XM
(length direction)
Weight
Ambient temperature ta
Housing temperature
tc,max
mm
mm
mm
mm
kg
°C
°C
OCD175-40LS-01... / DALI
184
59
39
175
0.690
-30 ... 55
75
OCD175-80LS-01... / DALI
184
59
39
175
0.690
-30 ... 55
75
OCD175-160LS-01... / DALI
235
59
39
226
0.900
-30 ... 55
75
Y
Z
Electronic control gears | ZITARES OCD
Case drawing
Xm
LED Components
X
Wiring diagrams
Wiring ECG output by use of geoDIM
LEDprotect
heatsink
LEDprotect
CH1
Wiring ECG output side with LEDprotect by use of DALI use
+
CH1
–
heatsink
+
–
DA
DA
DA
DA
Wiring ECG output with LEDprotect by use of control phase dimming
L
more ECG
N
LEDprotect
L
N
CH1
heatsink
+
–
CP
N
more ECG
BAG electronics | Product Catalogue 2014
93
ASTARES linear 2nd Generation
LED modules in linear shape
Product information
LED Modules
• Linear LED modules for use in linear and flat luminaires
• Simple electrical connection via plug terminals with
push buttons
• Module mounting via screw fastening
• Colour rendering CRI 84 for use in all standard
applications
LED Components
• Very low tolerance in colour consistency with 3 SDCM
• Very high efficiency of LED modules with up to
140 lm/W
• LED modules suitable for operation in SELV and nonSELV applications
Industry
    
Office & Commercial
    
Outdoor
    
Shop
    
Technical data
Conformity
EN 62031
Photometrical data
Color consistency (initial SDCM)
<3
EN 62471
Color consistency (after 50.000 h)
< 4
EN 61547
Light distribution
120 ° (FWHM)
Lambertian light
distribution
EN 55015
Tolerances of luminous flux
≤ 7.5 %
Photo biological safety
class 0
Electrical Data
Operation
Constant current
• Matrix topology of LED arrangement for avoidance of
dark zones with failure of individual LEDs
Nominal operating current
700 mA
Max. admissible operating current range
200 … 900 mA
• In compliance with Zhaga specification Book 7
Max. admissible string voltage (for
multiple connected modules)
300 VDC
Min. creepage and clearance distances
4.0 mm
Forward voltage
5%
Assembly informationen
Methode of fixing
M4 screws
Torque (pre-taped holes)
0.4 … 0.8 Nm
Type of connector
Push-In connector with
release option MOLEX
S-Poke 2P
Operating temperature
Max. case temperature (tc,max)
+75 °C
Max. performance temperature (tp,max)
+65 °C
Life time
94
Product Catalogue 2014 | BAG electronics
Nominal life time
50,000 h
Lumen maintenance (L-value)
80% (L80)
Mortality (B-value)
50% (B50)
Designations
Operating data
Designation
Material number
Typ. luminous flux
Typ. colour
temperature
Typ. colour
rendering
Rated operation
current
Max. operating
voltage
Typ. power
Typ. efficiency
lm
K
CRI
mA
VDC
W
lm/W
LMC-AS-110-830-LP-20/
L28W4
10107824
1050
3000
82
700
12
8
135
550
3000
82
350
12
4
135
LMC-AS-110-840-LP-20/
L28W4
10107825
1100
4000
84
700
12
8
140
550
4000
84
350
12
4
140
LMC-AS-200-830-LP-20/
L56W4
10107826
2100
3000
82
700
24
16
135
1050
3000
82
350
24
8
135
LMC-AS-200-840-LP-20/
L56W4
10107827
2200
4000
84
700
24
16
140
1100
4000
84
350
24
8
140
All operating data are refering to nominal operation at Tc = 65°C
Dimensions
Application notes
In case of any handling of the modules precautions against
mechanical stress and electrostatic discharge (ESD) have to
be considered.
5
40
220
Ø
7
4,
11
System design have to fulfill all safety standards related to
eletrical supply and installation conditions.
279,7
501
61
4,
7
40
5
Ø
11
57
281
560,7
LED Modules
82,9
Wiring diagrams
–
IN –
+
IN +
OUT –
OUT+
–
IN –
+
IN +
OUT –
OUT+
IN –
IN +
LED Components
ECG/EVG
OUT –
OUT+
ECG/EVG
See accessories page 150
BAG electronics | Product Catalogue 2014
95
ASTARES plane 2nd Generation
LED modules in planar shape
Product information
LED Modules
• Flat LED modules for use in flat luminaires with diffuse
covers
Industry
    
Office & Commercial
    
Outdoor
    
Shop
    
Technical data
Conformity
EN 62031
Photometrical data
LED Components
Color consistency (initial SDCM)
<3
EN 62471
Color consistency (after 50.000 h)
<4
EN 61547
• High flexibility with installation in luminaires via
conventional plug terminals for use of standard
connection cables
Light distribution
120 ° (FWHM)
Lambertian light
distribution
EN 55015
• Optimised temperature distribution for simplified
thermal management in the luminaire
Tolerances of luminous flux
≤ 7.5 %
Photo biological safety
class 0
• Simple electrical interconnection of LED modules for
assembly of systems
• High value for colour rendering CRI 84
Electrical Data
• Low colour tolerance of 3 SDCM
Operation
• Very high efficiency of LED modules with up to
145 lm/W
Nominal operating current
700 mA
Max. admissible operating current range
400 … 1400 mA
Max. admissible string voltage (for
multiple connected modules)
120 DC
Min. creepage and clearance distances
2.5 mm
Forward voltage
5%
• Simple installation of modules in the luminaire via
screw fastenings
• Operation of LED modules optionally to dimmable or
non-dimmable ECG with constant current
• LED modules suitable for operation in SELV applications
• Matrix topology of LED arrangement for avoidance of
dark zones with failure of individual LEDs
Constant current
Assembly informationen
Methode of fixing
M4 screws, locking
of open PCB ends in
fixture
Torque (pre-taped holes)
0.4 … 0.8 Nm
Type of connector
Push-In connector with
release option MOLEX
S-Poke 2P
Operating temperature
Max. case temperature (tc,max)
+75 °C
Max. performance temperature (tp,max)
+65 °C
Life time
96
Product Catalogue 2014 | BAG electronics
Nominal life time
50,000 h
Lumen maintenance (L-value)
80% (L80)
Mortality (B-value)
50% (B50)
Designations
Operating data
Designation
Material number
Typ. luminous flux
Typ. colour
temperature
Typ. colour
rendering
Rated operation
current
Max. operating
voltage
Typ. power
Typ.
efficiency
lm
K
CRI
mA
VDC
W
lm/W
LMC-AS-120-840-PP-20
10112594
1250
4000
84
700
12
8
145
LMC-AS-120-830-PP-20
10112595
1200
3000
82
700
12
8
140
All operating data are refering to nominal operation at Tc = 65°C
Application notes
Dimensions
259
250
5,6
18
In case of any handling of the modules precautions against
mechanical stress and electrostatic discharge (ESD) have to
be considered.
18,5
14,5
250
199,75
System design have to fulfill all safety standards related to
eletrical supply and installation conditions.
22
12
1,6
LED Modules
Wiring diagrams
–
+
LED Components
ECG/EVG
BAG electronics | Product Catalogue 2014
97
NEXARES 2nd generation
All-In-One-systems
Product information
LED Modules
• Flat LED light engine with integral LED module and
electronic control gear in a single unit for use in
luminaires with diffuse cover
• Suitable for direct connection to mains voltage supply
220 - 240 V; 50 ... 60 Hz
Industry
    
Office & Commercial
    
Outdoor
    
Shop
    
Technical data
LED Components
• Optimised temperature distribution for simplified
thermal management in the luminaire
• Low luminance tolerances via integrated current
control on the PCB
• High value for colour rendering CRI 84
• Low colour tolerance of 3 SDCM
• High module efficiency of up to 135 lm/W
• Simple installation of modules in the luminaire via
screw fastenings
• Space-saving installation in the luminaire because no
additional control unit is needed
EN 62031
Photometrical data
Color consistency (initial SDCM)
<3
EN 62471
Color consistency (after 50.000 h)
<4
EN 61547
Light distribution
120 ° (FWHM)
Lambertian light
distribution
EN 55015
• System power factor > 0.95
• Extremely flat design with a construction height
of 8 mm with high uniformity of light distribution
Conformity
Tolerances of luminous flux
≤ 7.5 %
Photo biological safety
class 0
Operation
Mains voltage supply
Rated voltage range
220 ... 240 [V]
Rated frequency
50 ... 60 [Hz]
Min. creepage and clearance distances
4.0
Assembly informationen
Methode of fixing
M4 screws
Torque (pre-taped holes)
0.4 … 0.8 Nm
Type of connector
Push-In connector with
release option WAGO
(Series 2060)
Max. case temperature (tc,max)
+75 °C
Max. performance temperature (tp,max)
+65 °C
Life time
Product Catalogue 2014 | BAG electronics
EN 61347-2-13
Electrical Data
Operating temperature
98
EN 61347-1
Nominal life time
50,000 h
Lumen maintenance (L-value)
80% (L80)
Mortality (B-value)
50% (B50)
Designations
Operating data
Designation
Material number
Typ. luminous
intensity
Typ. colour
temperature
lm
K
LMM-NE-110-830-RP-02
10108580
1300
3000
Typ. colour
rendering index
Rated voltage
range
Rated
frequency
Rated operating Rated
current
power
Typ.
efficiency
VAC
HZ
mA
W
lm/W
82
220 ... 240
50 ... 60
45
10.4
125
LMM-NE-110-840-RP-02
10108581
1300
4000
84
220 ... 240
50 ... 60
42
9.6
135
LMM-NE-200-830-RP-02
10108582
2000
3000
82
220 ... 240
50 ... 60
70
16
125
LMM-NE-200-840-RP-02
10108583
2000
4000
84
220 ... 240
50 ... 60
65
14.8
135
All operating data are refering to nominal operation at Tc = 65°C
Dimensions
Application notes
1,6
In case of any handling of the modules precautions against
mechanical stress and electrostatic discharge (ESD) have to
be considered.
LED Components
LED Modules
1,6
System design have to fulfill all safety standards related to
eletrical supply and installation conditions.
Wiring diagrams
N L
BAG electronics | Product Catalogue 2014
99
100
Product Catalogue 2014 | BAG electronics
Komponentenforfürfluorescent
Components
Leuchtstofflampen
lamps
Elektronische
Electronic
control
Vorschaltgeräte
units for
für
T5-fluorescent
T5
Leuchtstofflampen
lamps
MLS EVO
MLD EVO DIM DALI
BCS PRIMUS
BCD 1-10 V
T5 and
und TC-L | Multi-Lamp-Technology
Multi-Lamp-Technologie | linear ..............
...............102
112
T5 and
und TC-L | Multi-Lamp-Technology
Multi-Lamp-Technologie | linear ..............
...............106
116
T5 and
und TC-L/F | linear ...........................................................
............................................................110
120
T5 | linear ..................................................................................124
...................................................................................114
Electronic control units for
T8 fluorescent lamps
Elektronische
BCS
PRIMUS
Vorschaltgeräte
T8 | linear ..................................................................................128
für
BCD 1-10 V
T8 and TC-L/F | linear........................................................... 130
BCS PRIMUS
BCD 1-10 V
T8 | linear .................................................................................. 118
T8 und TC-L/F | linear .......................................................... 120
T8- Leuchtstofflampen
fluorescent lamps
BCS TC
CFL, T5 and T8 | compact ......................................................134
BCS TCTWINGLE
CFL, T5 and T8 | compact ......................................................136
BCS TCTWINGLE
CFL, T5 and T8 | independent .............................................. 140
BCS TC
Elektronische
Vorschaltgeräte
CFL, T5 and T8 | linear
für ............................................................144
EBS MINIPOWER
CFL, T5 and T8 | compact ......................................................148
BCD TC DALI
Kompaktleuchtstofflampen
CFL, T5 and T8 | Twingle-Technology |compact ................152
BCS TC 1-10 V
BCD
CFL, T5 and
und T8 | Twingle-Technology
kompakt ......................................................124
|compact ................154
BCS TCTWINGLE
BCD
CFL 1-10 V
CFL, and
CFL
T5 und
T5 |T8
compact
| kompakt
.............................................................156
......................................................126
BCS TCTWINGLE
CFL, T5 und T8 | unabhängig ............................................... 130
BCS TC
CFL, T5 und T8 | linear ............................................................134
EBS MINIPOWER
CFL, T5 und T8 | kompakt ......................................................138
BCD TC DALI
CFL, T5 und T8 | Twingle-Technologie |kompakt ..............142
BCD TC 1-10 V
CFL, T5 und T8 | Twingle-Technologie |kompakt ..............144
BCD CFL 1-10 V
CFL und T5 | kompakt.............................................................146
BAG electronics | Product Catalogue 2014
Komponenten
Components for
für fluorescent
Leuchtstofflampen
lamps
Electronic control units for compact
101
Productfinder - Selection table
Power
Number
of Lamps
Description
Order No.
[W]
T5
102
Lenght
X
Width
Y
Height
Z
[mm]
[mm]
[mm]
Interface
Page
6
1
EBS16.1C-01/220-240
10050989
80
41
19
-
148
6
1
EBS16.1M-01/220-240
10050993
150
22
22
-
148
8
1
EBS16.1C-01/220-240
10050989
80
41
19
-
148
8
1
EBS16.1C-01/220-240
10050989
80
41
19
-
148
8
1
EBS16.1M-01/220-240
10050993
150
22
22
-
148
14
1
BCD35.1F-01/220-240/1-10V
10097244
360
30
21
1-10V
124
14
1
BCS21.1-2LS-01/220-240
10095043
150
42
30
-
112
14
1
BCS21.1-2Q-01/220-240
10097543
103
67
30
-
136
14
1
BCS21.1-2QI-01/220-240
10095743
180
86
33
-
140
14
1
BCS35.1FX-11/220-240
10077579
280
30
21
-
120
14
1
EBS21.1M-01/220-240
10050994
150
22
22
-
148
14
1
MLD39.1FR-11/220-240/DALI
10097811
360
30
21
DALI, Push-Dim
116
14
1
MLS39.1-2FR-11/220-240
10092026
280
30
21
-
112
14
2
BCD35.2F-01/220-240/1-10V
10097294
425
30
21
1-10V
124
14
2
BCS21.1-2LS-01/220-240
10095043
150
42
30
-
112
14
2
BCS21.1-2Q-01/220-240
10097543
103
67
30
-
136
14
2
BCS21.1-2QI-01/220-240
10095743
180
86
33
-
140
14
2
BCS35.2FX-11/220-240
10077580
280
30
21
-
120
14
2
MLD39.2FR-11/220-240/DALI
10092117
360
30
21
DALI, Push-Dim
116
14
2
MLS39.1-2FR-11/220-240
10092026
280
30
21
-
112
14
3
BCD14.3F-01/220-240/1-10V
10097281
360
39
21
1-10V
124
14
3
BCS14.3-4FR-01/220-240
10052868
280
42
21
-
120
14
3
MLD14/24.3FR-04/220-240/DALI
10105150
360
39
22
DALI, Push-Dim
116
14
3
MLS14/24.3-4.FR-11/220-240
10095345
280
39
21
-
112
14
4
BCD14.4F-01/220-240/1-10V
10097291
360
39
21
1-10V
124
14
4
BCS14.3-4FR-01/220-240
10052868
280
42
21
-
120
14
4
MLD14/24.4FR-04/220-240/DALI
10105151
360
39
22
DALI, Push-Dim
116
14
4
MLS14/24.3-4.FR-11/220-240
10095345
280
39
21
-
112
14
1
EBS16.1C-01/220-240
10050989
80
41
19
-
148
14
1
EBS16.1M-01/220-240
10050993
150
22
22
-
148
21
1
BCD35.1F-01/220-240/1-10V
10097244
360
30
21
1-10V
124
21
1
BCS21.1-2LS-01/220-240
10095043
150
42
30
-
112
21
1
BCS21.1-2Q-01/220-240
10097543
103
67
30
-
136
21
1
BCS21.1-2QI-01/220-240
10095743
180
86
33
-
140
21
1
BCS35.1FX-11/220-240
10077579
280
30
21
-
120
21
1
EBS21.1M-01/220-240
10050994
150
22
22
-
148
21
1
MLD39.1FR-11/220-240/DALI
10097811
360
30
21
DALI, Push-Dim
116
21
1
MLS39.1-2FR-11/220-240
10092026
280
30
21
-
112
21
2
BCD35.2F-01/220-240/1-10V
10097294
420
30
20
1-10V
124
21
2
BCS35.2FX-11/220-240
10077580
280
30
21
-
120
21
2
MLD39.2FR-11/220-240/DALI
10092117
360
30
21
DALI, Push-Dim
116
21
2
MLS39.1-2FR-11/220-240
10092026
280
30
21
-
112
24
1
BCD39.1F-01/220-240/1-10V
10097246
360
30
21
1-10V
124
24
1
BCD57.1/32.2Q-01/220-240/1-10V
10096387
103
67
30
1-10V
154
24
1
BCD57.1/32.2Q-01/220-240/DALI
10096397
103
67
30
DALI, Push-Dim
152
24
1
BCS39.1FX-11/220-240
10077581
280
30
21
-
120
24
1
BCS42.1/26.2LS-01/220-240
10095045
150
42
30
-
112
24
1
BCS42.1/26.2Q-01/220-240
10097545
103
67
30
-
136
24
1
BCS42.1/26.2QI-01/220-240
10095745
180
86
33
-
140
Product Catalogue 2014 | BAG electronics
Productfinder - Selection table
Power
Number
of Lamps
Description
Order No.
[W]
Lenght
X
Width
Y
Height
Z
[mm]
[mm]
[mm]
Interface
Page
24
1
BCS42.1Q-01/220-240
10097535
103
67
30
-
134
24
1
EBS26.1C-01/220-240
10050992
80
41
19
-
148
24
1
EBS26.1M-01/220-240
10050996
150
22
22
-
148
24
1
MLD39.1FR-11/220-240/DALI
10097811
360
30
21
DALI, Push-Dim
116
24
1
MLS39.1-2FR-11/220-240
10092026
280
30
21
-
112
24
2
BCD39.2F-01/220-240/1-10V
10097296
425
30
21
1-10V
124
24
2
BCD57.1/32.2Q-01/220-240/1-10V
10096387
103
67
30
1-10V
154
24
2
BCD57.1/32.2Q-01/220-240/DALI
10096397
103
67
30
DALI, Push-Dim
152
24
2
BCS39.2FX-11/220-240
10077582
280
30
21
-
120
24
2
BCS42.1/26.2LS-01/220-240
10095045
150
42
30
-
112
24
2
BCS42.1/26.2Q-01/220-240
10097545
103
67
30
-
136
24
2
BCS42.1/26.2QI-01/220-240
10095745
180
86
33
-
140
24
2
MLD39.2FR-11/220-240/DALI
10092117
360
30
21
DALI, Push-Dim
116
24
2
MLS39.1-2FR-11/220-240
10092026
280
30
21
-
112
24
3
BCD18.3-4F-01/220-240/1-10V
10097171
360
39
21
1-10V
130
24
3
MLD14/24.3FR-04/220-240/DALI
10105150
360
39
22
DALI, Push-Dim
116
24
3
MLS14/24.3-4.FR-11/220-240
10095345
280
39
21
-
112
24
4
MLD14/24.4FR-04/220-240/DALI
10105151
360
39
22
DALI, Push-Dim
116
24
4
MLS14/24.3-4.FR-11/220-240
10095345
280
39
21
-
112
28
1
BCD35.1F-01/220-240/1-10V
10097244
360
30
21
1-10V
124
28
1
BCS35.1FX-11/220-240
10077579
280
30
21
-
120
28
1
MLD54.1FR-11/220-240/DALI
10097815
360
30
21
DALI, Push-Dim
116
28
1
MLS80.1/54.2FR-11/220-240
10071609
280
30
21
-
112
28
1
MLS80.1FR-11/220-240
10071608
280
30
21
-
112
28
2
BCD35.2F-01/220-240/1-10V
10097294
420
30
20
1-10V
124
28
2
BCS35.2FX-11/220-240
10077580
280
30
21
-
120
28
2
MLD54.2FR-11/220-240/DALI
10092121
360
30
21
DALI, Push-Dim
116
28
2
MLS80.1/54.2FR-11/220-240
10071609
280
30
21
-
112
35
1
BCD35.1F-01/220-240/1-10V
10097244
360
30
21
1-10V
124
35
1
BCS35.1FX-11/220-240
10077579
280
30
21
-
120
35
1
MLD54.1FR-11/220-240/DALI
10097815
360
30
21
DALI, Push-Dim
116
35
1
MLD80.1FR-11/220-240/DALI
10097820
360
30
21
DALI, Push-Dim
116
35
1
MLS80.1/54.2FR-11/220-240
10071609
280
30
21
-
112
35
1
MLS80.1FR-11/220-240
10071608
280
30
21
-
112
35
2
BCD35.2F-01/220-240/1-10V
10097294
420
30
20
1-10V
124
35
2
BCS35.2FX-11/220-240
10077580
280
30
21
-
120
35
2
MLD54.2FR-11/220-240/DALI
10092121
360
30
21
DALI, Push-Dim
116
35
2
MLD80.2FR-11/220-240/DALI
10101905
425
30
21
DALI, Push-Dim
116
35
2
MLS80.1/54.2FR-11/220-240
10071609
280
30
21
-
112
39
1
BCD39.1F-01/220-240/1-10V
10097246
360
30
21
1-10V
124
39
1
BCD57.1/32.2Q-01/220-240/1-10V
10096387
103
67
30
1-10V
154
39
1
BCD57.1/32.2Q-01/220-240/DALI
10096397
103
67
30
DALI, Push-Dim
152
39
1
BCS39.1FX-11/220-240
10077581
280
30
21
-
120
39
1
BCS42.1/26.2LS-01/220-240
10095045
150
42
30
-
112
39
1
BCS42.1/26.2Q-01/220-240
10097545
103
67
30
-
136
39
1
BCS42.1/26.2QI-01/220-240
10095745
180
86
33
-
140
39
1
BCS42.1Q-01/220-240
10097535
103
67
30
-
134
39
1
MLD39.1FR-11/220-240/DALI
10097811
360
30
21
DALI, Push-Dim
116
39
1
MLS39.1-2FR-11/220-240
10092026
280
30
21
-
112
T5
BAG electronics | Product Catalogue 2014
103
Productfinder - Selection table
Power
Number
of Lamps
Description
Order No.
[W]
T5
104
Lenght
X
Width
Y
Height
Z
[mm]
[mm]
[mm]
Interface
Page
39
2
BCD39.2F-01/220-240/1-10V
10097296
425
30
21
1-10V
124
39
2
BCS39.2FX-11/220-240
10077582
280
30
21
-
120
39
2
MLD39.2FR-11/220-240/DALI
10092117
360
30
21
DALI, Push-Dim
116
39
2
MLS39.1-2FR-11/220-240
10092026
280
30
21
-
112
49
1
BCD49.1F-01/220-240/1-10V
10097247
360
30
21
1-10V
124
49
1
BCS49.1FX-11/220-240
10077583
280
30
21
-
120
49
1
MLD54.1FR-11/220-240/DALI
10097815
360
30
21
DALI, Push-Dim
116
49
1
MLD80.1FR-11/220-240/DALI
10097820
360
30
21
DALI, Push-Dim
116
49
1
MLS80.1/54.2FR-11/220-240
10071609
280
30
21
-
112
49
1
MLS80.1FR-11/220-240
10071608
280
30
21
-
112
49
2
BCD49.2F-01/220-240/1-10V
10097297
425
30
21
1-10V
124
49
2
BCS49.2FX-11/220-240
10077584
280
30
21
-
120
49
2
MLD54.2FR-11/220-240/DALI
10092121
360
30
21
DALI, Push-Dim
116
49
2
MLD80.2FR-11/220-240/DALI
10101905
425
30
21
DALI, Push-Dim
116
49
2
MLS80.1/54.2FR-11/220-240
10071609
280
30
21
-
112
54
1
BCD54.1F-01/220-240/1-10V
10097248
360
30
21
1-10V
124
54
1
BCS54.1FX-11/220-240
10077585
280
30
21
-
120
54
1
MLD54.1FR-11/220-240/DALI
10097815
360
30
21
DALI, Push-Dim
116
54
1
MLS80.1/54.2FR-11/220-240
10071609
280
30
21
-
112
54
1
MLS80.1FR-11/220-240
10071608
280
30
21
-
112
54
2
BCD54.2F-01/220-240/1-10V
10097298
425
30
21
1-10V
124
54
2
BCS54.2FX-11/220-240
10077586
280
30
21
-
120
54
2
MLD54.2FR-11/220-240/DALI
10092121
360
30
21
DALI, Push-Dim
116
54
2
MLS80.1/54.2FR-11/220-240
10071609
280
30
21
-
112
80
1
BCD80.1F-01/220-240/1-10V
10097249
360
30
21
1-10V
124
80
1
BCS80.1FX-11/220-240
10077587
280
30
21
-
120
80
1
MLD80.1FR-11/220-240/DALI
10097820
360
30
21
DALI, Push-Dim
116
80
1
MLS80.1/54.2FR-11/220-240
10071609
280
30
21
-
112
80
1
MLS80.1FR-11/220-240
10071608
280
30
21
-
112
80
2
BCD80.2F-01/220-240/1-10V
10097299
425
30
21
1-10V
124
80
2
MLD80.2FR-11/220-240/DALI
10101905
425
30
21
DALI, Push-Dim
116
Product Catalogue 2014 | BAG electronics
Productfinder - Selection table
Power
Number
of Lamps
Description
Order No.
[W]
Lenght
X
Width
Y
Height
Z
Interface
Page
154
[mm]
[mm]
[mm]
22
1
BCD57.1/32.2Q-01/220-240/1-10V
10096387
103
67
30
1-10V
22
1
BCD57.1/32.2Q-01/220-240/DALI
10096397
103
67
30
DALI, Push-Dim
152
22
1
BCS42.1/26.2LS-01/220-240
10095045
150
42
30
-
112
22
1
BCS42.1/26.2Q-01/220-240
10097545
103
67
30
-
136
22
1
BCS42.1/26.2QI-01/220-240
10095745
180
86
33
-
140
22
1
BCS42.1Q-01/220-240
10097535
103
67
30
-
134
22
1
EBS26.1C-01/220-240
10050992
80
41
19
-
148
22
1
EBS26.1M-01/220-240
10050996
150
22
22
-
148
22
2
BCD57.1/32.2Q-01/220-240/1-10V
10096387
103
67
30
1-10V
154
22
2
BCD57.1/32.2Q-01/220-240/DALI
10096397
103
67
30
DALI, Push-Dim
152
22
2
BCS42.1/26.2LS-01/220-240
10095045
150
42
30
-
112
22
2
BCS42.1/26.2Q-01/220-240
10097545
103
67
30
-
136
22
2
BCS42.1/26.2QI-01/220-240
10095745
180
86
33
-
140
22
2
BCS70.1/42.2Q-01/220-240
10097546
103
67
30
-
136
40
1
BCD57.1/32.2Q-01/220-240/1-10V
10096387
103
67
30
1-10V
154
40
1
BCD57.1/32.2Q-01/220-240/DALI
10096397
103
67
30
DALI, Push-Dim
152
40
1
BCS42.1/26.2LS-01/220-240
10095045
150
42
30
-
112
40
1
BCS42.1/26.2Q-01/220-240
10097545
103
67
30
-
136
40
1
BCS42.1/26.2QI-01/220-240
10095745
180
86
33
-
140
40
1
BCS42.1Q-01/220-240
10097535
103
67
30
-
134
55
1
BCD55.1Q-01/220-240/1-10V
10096388
103
67
30
-
156
55
1
BCS55.1Q-01/220-240/T5C
10097634
103
67
30
-
134
60
1
BCD60.1Q-01/220-240/1-10V
10096389
103
67
30
-
156
60
1
BCS60.1Q-01/220-240
10097635
103
67
30
-
134
T5C
T5
BAG electronics | Product Catalogue 2014
105
Productfinder - Selection table
Power
Lamp
Number Description
of Lamps
Order No.
[W]
T8
T5
106
Lenght
X
Width
Y
Height
Z
Interface
Page
[mm]
[mm]
[mm]
15
1
T8
BCD57.1/32.2Q-01/220-240/1-10V
10096387
103
67
30
1-10V
154
15
1
T8
BCD57.1/32.2Q-01/220-240/DALI
10096397
103
67
30
DALI, Push-Dim
152
15
1
T8
BCS42.1/26.2LS-01/220-240
10095045
150
42
30
-
112
15
1
T8
BCS42.1/26.2Q-01/220-240
10097545
103
67
30
-
136
15
1
T8
BCS42.1/26.2QI-01/220-240
10095745
180
86
33
-
140
15
1
T8
BCS42.1Q-01/220-240
10097535
103
67
30
-
134
15
1
T8
EBS26.1C-01/220-240
10050992
80
41
19
-
148
15
2
T8
BCD57.1/32.2Q-01/220-240/1-10V
10096387
103
67
30
1-10V
154
15
2
T8
BCD57.1/32.2Q-01/220-240/DALI
10096397
103
67
30
DALI, Push-Dim
152
15
2
T8
BCS42.1/26.2LS-01/220-240
10095045
150
42
30
-
112
15
2
T8
BCS42.1/26.2Q-01/220-240
10097545
103
67
30
-
136
15
2
T8
BCS42.1/26.2QI-01/220-240
10095745
180
86
33
-
140
18
1
T8
BCD18.1F-01/220-240/1-10V
10097143
360
30
21
1-10V
130
18
1
T8
BCD57.1/32.2Q-01/220-240/1-10V
10096387
103
67
30
1-10V
154
18
1
T8
BCD57.1/32.2Q-01/220-240/DALI
10096397
103
67
30
DALI, Push-Dim
152
18
1
T8
BCS18.1FX-11/220-240
10077588
280
30
21
-
128
18
1
T8
BCS39.1FX-11/220-240
10077581
280
30
21
-
120
18
1
T8
BCS42.1/26.2LS-01/220-240
10095045
150
42
30
-
112
18
1
T8
BCS42.1/26.2Q-01/220-240
10097545
103
67
30
-
136
18
1
T8
BCS42.1/26.2QI-01/220-240
10095745
180
86
33
-
140
18
1
T8
BCS42.1Q-01/220-240
10097535
103
67
30
-
134
18
1
T8
EBS16.1C-01/220-240
10050989
80
41
19
-
148
18
1
T8
EBS16.1M-01/220-240
10050993
150
22
22
-
148
18
1
T8
EBS26.1C-01/220-240
10050992
80
41
19
-
148
18
1
T8
EBS26.1M-01/220-240
10050996
150
22
22
-
148
18
2
T8
BCD18.2F-01/220-240/1-10V
10097193
425
30
21
1-10V
130
18
2
T8
BCD57.1/32.2Q-01/220-240/1-10V
10096387
103
67
30
1-10V
154
18
2
T8
BCD57.1/32.2Q-01/220-240/DALI
10096397
103
67
30
DALI, Push-Dim
152
18
2
T8
BCS18.2FX-11/220-240
10077589
280
30
21
-
128
18
2
T8
BCS42.1/26.2LS-01/220-240
10095045
150
42
30
-
112
18
2
T8
BCS42.1/26.2Q-01/220-240
10097545
103
67
30
-
136
18
2
T8
BCS42.1/26.2QI-01/220-240
10095745
180
86
33
-
140
18
3
T8
BCD18.3-4F-01/220-240/1-10V
10097171
360
39
21
1-10V
130
18
3
T8
BCS18.3-4LR-01/220-240
10050999
290
42
28
-
128
18
3
T8
MLD14/24.3FR-04/220-240/DALI
10105150
360
39
22
DALI, Push-Dim
116
18
4
T8
BCD18.3-4F-01/220-240/1-10V
10097171
360
39
21
1-10V
130
18
4
T8
BCS18.3-4LR-01/220-240
10050999
290
42
28
-
128
18
4
T8
MLD14/24.4FR-04/220-240/DALI
10105151
360
39
22
DALI, Push-Dim
116
30
1
T8
BCD18.1F-01/220-240/1-10V
10097143
360
30
21
1-10V
130
30
1
T8
BCS28.1LS-01/220-240
10097426
150
42
30
-
112
30
2
T8
BCD18.2F-01/220-240/1-10V
10097193
425
30
21
1-10V
130
36
1
T8
BCD36.1F-01/220-240/1-10V
10097144
360
30
21
1-10V
130
36
1
T8
BCD57.1/32.2Q-01/220-240/1-10V
10096387
103
67
30
1-10V
154
36
1
T8
BCD57.1/32.2Q-01/220-240/DALI
10096397
103
67
30
DALI, Push-Dim
152
36
1
T8
BCS36.1FX-11/220-240
10077590
280
30
21
-
128
36
1
T8
BCS38.1LS-01/220-240
10097427
150
42
30
-
112
36
1
T8
BCS39.1FX-11/220-240
10077581
280
30
21
-
120
36
1
T8
BCS42.1/26.2LS-01/220-240
10095045
150
42
30
-
112
36
1
T8
BCS42.1/26.2Q-01/220-240
10097545
103
67
30
-
136
36
1
T8
BCS42.1/26.2QI-01/220-240
10095745
180
86
33
-
140
36
1
T8
BCS42.1Q-01/220-240
10097535
103
67
30
-
134
36
2
T8
BCD36.2F-01/220-240/1-10V
10097194
425
30
21
1-10V
130
36
2
T8
BCD57.1/32.2Q-01/220-240/1-10V
10096387
103
67
30
1-10V
154
36
2
T8
BCD57.1/32.2Q-01/220-240/DALI
10096397
103
67
30
DALI, Push-Dim
152
36
2
T8
BCS36.2FX-11/220-240
10077591
280
30
21
-
128
36
3
T8
MLS14/24.3-4.FR-11/220-240
10095345
280
39
21
-
112
58
1
T8
BCD58.1F-01/220-240/1-10V
10097145
360
30
21
1-10V
130
58
1
T8
BCS54.1FX-11/220-240
10077585
280
30
21
-
120
58
1
T8
BCS58.1FX-11/220-240
10077592
280
30
21
-
128
Product Catalogue 2014 | BAG electronics
Productfinder - Selection table
Power
Lamp
Number Description
of Lamps
Order No.
[W]
Lenght
X
Width
Y
Height
Z
[mm]
Interface
Page
[mm]
[mm]
58
2
T8
BCD58.2F-01/220-240/1-10V
10097195
425
30
21
1-10V
130
58
2
T8
BCS58.2FX-11/220-240
10077593
280
30
21
-
128
10
1
TC-DD
BCS21.1-2LS-01/220-240
10095043
150
42
30
-
112
10
1
TC-DD
BCS21.1-2Q-01/220-240
10097543
103
67
30
-
136
10
1
TC-DD
BCS21.1-2QI-01/220-240
10095743
180
86
33
-
140
10
1
TC-DD
EBS16.1C-01/220-240
10050989
80
41
19
-
148
10
2
TC-DD
BCS21.1-2LS-01/220-240
10095043
150
42
30
-
112
10
2
TC-DD
BCS21.1-2Q-01/220-240
10097543
103
67
30
-
136
10
2
TC-DD
BCS21.1-2QI-01/220-240
10095743
180
86
33
-
140
16
1
TC-DD
BCS21.1-2LS-01/220-240
10095043
150
42
30
-
112
16
1
TC-DD
BCS21.1-2Q-01/220-240
10097543
103
67
30
-
136
16
1
TC-DD
BCS21.1-2QI-01/220-240
10095743
180
86
33
-
140
16
1
TC-DD
EBS16.1C-01/220-240
10050989
80
41
19
-
148
16
1
TC-DD
EBS16.1M-01/220-240
10050993
150
22
22
-
148
16
2
TC-DD
BCS21.1-2LS-01/220-240
10095043
150
42
30
-
112
16
2
TC-DD
BCS21.1-2Q-01/220-240
10097543
103
67
30
-
136
16
2
TC-DD
BCS21.1-2QI-01/220-240
10095743
180
86
33
-
140
28
1
TC-DD
BCS28.1LS-01/220-240
10097426
150
42
30
-
112
28
1
TC-DD
BCS28.1Q-01/220-240
10097436
103
67
30
-
134
38
1
TC-DD
BCS38.1LS-01/220-240
10097427
150
42
30
-
112
38
1
TC-DD
BCS38.1Q-01/220-240
10097437
103
67
30
-
134
55
1
TC-DD
BCS55.1Q-01/220-240/TC-DD
10097439
103
67
30
-
134
T8
TC-DD
T5
BAG electronics | Product Catalogue 2014
107
Productfinder - Selection table
Power
Lamp
Number Description
of Lamps
Order No.
[W]
TC-DEL
TC-TEL
TC-SEL
T5
108
Lenght
X
Width
Y
Height
Z
Interface
Page
[mm]
[mm]
[mm]
7
TC-SEL
1
EBS16.1C-01/220-240
10050989
80
41
19
-
148
7
TC-SEL
1
EBS16.1M-01/220-240
10050993
150
22
22
-
148
9
TC-SEL
1
BCS21.1-2LS-01/220-240
10095043
150
42
30
-
112
9
TC-SEL
1
BCS21.1-2QI-01/220-240
10095743
180
86
33
-
140
9
TC-SEL
1
EBS16.1C-01/220-240
10050989
80
41
19
-
148
9
TC-SEL
1
EBS16.1M-01/220-240
10050993
150
22
22
-
148
9
TC-SEL
2
BCS21.1-2LS-01/220-240
10095043
150
42
30
-
112
9
TC-SEL
2
BCS21.1-2Q-01/220-240
10097543
103
67
30
-
136
9
TC-SEL
2
BCS21.1-2QI-01/220-240
10095743
180
86
33
-
140
9
TC-SEL
1
BCS21.1-2Q-01/220-240
10097543
103
67
30
-
136
10
TC-DEL
1
BCS21.1-2LS-01/220-240
10095043
150
42
30
-
112
10
TC-DEL
1
BCS21.1-2Q-01/220-240
10097543
103
67
30
-
136
10
TC-DEL
1
BCS21.1-2QI-01/220-240
10095743
180
86
33
-
140
10
TC-DEL
1
EBS16.1C-01/220-240
10050989
80
41
19
-
148
10
TC-DEL
1
EBS16.1M-01/220-240
10050993
150
22
22
-
148
10
TC-DEL
2
BCS21.1-2LS-01/220-240
10095043
150
42
30
-
112
10
TC-DEL
2
BCS21.1-2Q-01/220-240
10097543
103
67
30
-
136
10
TC-DEL
2
BCS21.1-2QI-01/220-240
10095743
180
86
33
-
140
11
TC-SEL
1
BCS21.1-2LS-01/220-240
10095043
150
42
30
-
112
11
TC-SEL
1
BCS21.1-2Q-01/220-240
10097543
103
67
30
-
136
11
TC-SEL
1
BCS21.1-2QI-01/220-240
10095743
180
86
33
-
140
11
TC-SEL
1
EBS16.1C-01/220-240
10050989
80
41
19
-
148
11
TC-SEL
1
EBS16.1M-01/220-240
10050993
150
22
22
-
148
11
TC-SEL
2
BCS21.1-2LS-01/220-240
10095043
150
42
30
-
112
11
TC-SEL
2
BCS21.1-2Q-01/220-240
10097543
103
67
30
-
136
11
TC-SEL
2
BCS21.1-2QI-01/220-240
10095743
180
86
33
-
140
13
TC-DEL
1
BCD13.1-2Q-01/220-240/1-10V
10096393
103
67
30
1-10V
154
13
TC-DEL
1
BCS21.1-2LS-01/220-240
10095043
150
42
30
-
112
13
TC-DEL
1
BCS21.1-2Q-01/220-240
10097543
103
67
30
-
136
13
TC-DEL
1
BCS21.1-2QI-01/220-240
10095743
180
86
33
-
140
13
TC-DEL
1
EBS21.1C-01/220-240
10050990
80
41
19
-
148
13
TC-DEL
1
EBS21.1M-01/220-240
10050994
150
22
22
-
148
13
TC-TEL
2
BCD13.1-2Q-01/220-240/1-10V
10096393
103
67
30
1-10V
154
13
TC-TEL
2
BCS21.1-2LS-01/220-240
10095043
150
42
30
-
112
13
TC-TEL
2
BCS21.1-2Q-01/220-240
10097543
103
67
30
-
136
13
TC-TEL
2
BCS21.1-2QI-01/220-240
10095743
180
86
33
-
140
18
TC-DEL
1
BCD18.1-2Q-01/220-240/1-10V
10096385
103
67
30
1-10V
154
18
TC-DEL
1
BCD18.1-2Q-01/220-240/DALI
10096395
103
67
30
DALI, Push-Dim
152
18
TC-DEL
1
BCS18.1-2LS-01/220-240
10095044
150
42
30
-
112
18
TC-DEL
1
BCS18.1-2Q-01/220-240
10097544
103
67
30
-
136
18
TC-DEL
1
BCS18.1-2QI-01/220-240
10095744
180
86
33
-
140
18
TC-DEL
1
BCS18.1Q-01/220-240
10097534
103
67
30
-
134
18
TC-DEL
1
EBS21.1C-01/220-240
10050990
80
41
19
-
148
18
TC-DEL
1
EBS21.1M-01/220-240
10050994
150
22
22
-
148
18
TC-DEL
2
BCS18.1-2LS-01/220-240
10095044
150
42
30
-
112
18
TC-DEL
2
BCS18.1-2Q-01/220-240
10097544
103
67
30
-
136
18
TC-DEL
2
BCS18.1-2QI-01/220-240
10095744
180
86
33
-
140
18
TC-TEL
2
BCD18.1-2Q-01/220-240/1-10V
10096385
103
67
30
1-10V
154
18
TC-TEL
2
BCD18.1-2Q-01/220-240/DALI
10096395
103
67
30
DALI, Push-Dim
152
26
TC-DEL
1
BCS42.1/26.2LS-01/220-240
10095045
150
42
30
-
112
26
TC-DEL
1
BCS42.1/26.2Q-01/220-240
10097545
103
67
30
-
136
26
TC-DEL
1
BCS42.1/26.2QI-01/220-240
10095745
180
86
33
-
140
26
TC-DEL
1
BCS42.1Q-01/220-240
10097535
103
67
30
-
134
26
TC-DEL
1
BCS70.1/42.2Q-01/220-240
10097546
103
67
30
-
136
26
TC-DEL
1
EBS26.1C-01/220-240
10050992
80
41
19
-
148
26
TC-DEL
1
EBS26.1M-01/220-240
10050996
150
22
22
-
148
26
TC-DEL
1
SCS42.1Q-01/220-240/4kV
166772
103
67
31
-
134
26
TC-DEL
2
BCS42.1/26.2LS-01/220-240
10095045
150
42
30
-
112
Product Catalogue 2014 | BAG electronics
Productfinder - Selection table
Power
Lamp
Number Description
of Lamps
Order No.
[W]
Lenght
X
Width
Y
Height
Z
Interface
Page
[mm]
[mm]
[mm]
26
TC-DEL
2
BCS42.1/26.2Q-01/220-240
10097545
103
67
30
-
136
26
TC-DEL
2
BCS42.1/26.2QI-01/220-240
10095745
180
86
33
-
140
26
TC-DEL
2
BCS70.1/42.2Q-01/220-240
10097546
103
67
30
-
136
26
TC-TEL
1
BCD57.1/32.2Q-01/220-240/1-10V
10096387
103
67
30
1-10V
154
26
TC-TEL
1
BCD57.1/32.2Q-01/220-240/DALI
10096397
103
67
30
DALI, Push-Dim
152
26
TC-TEL
2
BCD42.2Q-01/220-240/1-10V
10097580
123
102
33
-
156
154
26
TC-TEL
2
BCD57.1/32.2Q-01/220-240/1-10V
10096387
103
67
30
1-10V
26
TC-TEL
2
BCD57.1/32.2Q-01/220-240/DALI
10096397
103
67
30
DALI, Push-Dim
152
32
TC-TEL
1
BCD57.1/32.2Q-01/220-240/1-10V
10096387
103
67
30
1-10V
154
32
TC-TEL
1
BCD57.1/32.2Q-01/220-240/DALI
10096397
103
67
30
DALI, Push-Dim
152
32
TC-TEL
1
BCS42.1/26.2LS-01/220-240
10095045
150
42
30
-
112
32
TC-TEL
1
BCS42.1/26.2Q-01/220-240
10097545
103
67
30
-
136
32
TC-TEL
1
BCS42.1/26.2QI-01/220-240
10095745
180
86
33
-
140
32
TC-TEL
1
BCS42.1Q-01/220-240
10097535
103
67
30
-
134
32
TC-TEL
1
BCS70.1/42.2Q-01/220-240
10097546
103
67
30
-
136
32
TC-TEL
1
SCS42.1Q-01/220-240/4kV
166772
103
67
30
-
134
32
TC-TEL
2
BCD42.2Q-01/220-240/1-10V
10097580
123
102
33
-
156
32
TC-TEL
2
BCD57.1/32.2Q-01/220-240/1-10V
10096387
103
67
30
1-10V
154
32
TC-TEL
2
BCD57.1/32.2Q-01/220-240/DALI
10096397
103
67
30
DALI, Push-Dim
152
32
TC-TEL
2
BCS70.1/42.2Q-01/220-240
10097546
103
67
30
-
136
154
42
TC-TEL
1
BCD57.1/32.2Q-01/220-240/1-10V
10096387
103
67
30
1-10V
42
TC-TEL
1
BCD57.1/32.2Q-01/220-240/DALI
10096397
103
67
30
DALI, Push-Dim
152
42
TC-TEL
1
BCS42.1/26.2LS-01/220-240
10095045
150
42
30
-
112
42
TC-TEL
1
BCS42.1/26.2Q-01/220-240
10097545
103
67
30
-
136
42
TC-TEL
1
BCS42.1/26.2QI-01/220-240
10095745
180
86
33
-
140
42
TC-TEL
1
BCS42.1Q-01/220-240
10097535
103
67
30
-
134
42
TC-TEL
1
BCS70.1/42.2Q-01/220-240
10097546
103
67
30
-
136
42
TC-TEL
1
SCS42.1Q-01/220-240/4kV
166772
103
67
30
-
134
42
TC-TEL
2
BCD42.2Q-01/220-240/1-10V
10097580
123
102
33
-
156
42
TC-TEL
2
BCS70.1/42.2Q-01/220-240
10097546
103
67
30
-
136
57
TC-TEL
1
BCD57.1/32.2Q-01/220-240/1-10V
10096387
103
67
30
1-10V
154
57
TC-TEL
1
BCD57.1/32.2Q-01/220-240/DALI
10096397
103
67
30
DALI, Push-Dim
152
57
TC-TEL
1
BCS70.1/42.2Q-01/220-240
10097546
103
67
30
-
136
70
TC-TEL
1
BCS70.1/42.2Q-01/220-240
10097546
103
67
30
-
136
TC-DEL
TC-TEL
TC-SEL
T5
BAG electronics | Product Catalogue 2014
109
Productfinder - Selection table
Power
Lamp
Number Description
of Lamps
Order No.
[W]
TC-L/F
110
Lenght
X
Width
Y
Height
Z
Interface
Page
154
[mm]
[mm]
[mm]
18
TC-L, TC-F
1
BCD57.1/32.2Q-01/220-240/1-10V
10096387
103
67
30
1-10V
18
TC-L, TC-F
1
BCD57.1/32.2Q-01/220-240/DALI
10096397
103
67
30
DALI, Push-Dim
152
18
TC-L, TC-F
1
BCS39.1FX-11/220-240
10077581
280
30
21
-
120
18
TC-L, TC-F
1
BCS42.1/26.2LS-01/220-240
10095045
150
42
30
-
112
18
TC-L, TC-F
1
BCS42.1/26.2Q-01/220-240
10097545
103
67
30
-
136
18
TC-L, TC-F
1
BCS42.1/26.2QI-01/220-240
10095745
180
86
33
-
140
18
TC-L, TC-F
1
BCS42.1Q-01/220-240
10097535
103
67
30
-
134
18
TC-L, TC-F
1
EBS26.1C-01/220-240
10050992
80
41
19
-
148
18
TC-L, TC-F
1
EBS26.1M-01/220-240
10050996
150
22
22
-
148
116
18
TC-L, TC-F
1
MLD39.1FR-11/220-240/DALI
10097811
360
30
21
DALI, Push-Dim
18
TC-L, TC-F
1
MLS39.1-2FR-11/220-240
10092026
280
30
21
-
112
18
TC-L, TC-F
1
SCS42.1Q-01/220-240/4kV
166772
103
67
30
-
134
154
18
TC-L, TC-F
2
BCD57.1/32.2Q-01/220-240/1-10V
10096387
103
67
30
1-10V
18
TC-L, TC-F
2
BCD57.1/32.2Q-01/220-240/DALI
10096397
103
67
30
DALI, Push-Dim
152
18
TC-L, TC-F
2
BCS39.2FX-11/220-240
10077582
280
30
21
-
120
18
TC-L, TC-F
2
BCS42.1/26.2LS-01/220-240
10095045
150
42
30
-
112
18
TC-L, TC-F
2
BCS42.1/26.2Q-01/220-240
10097545
103
67
30
-
136
18
TC-L, TC-F
2
BCS42.1/26.2QI-01/220-240
10095745
180
86
33
-
140
18
TC-L, TC-F
2
MLD39.2FR-11/220-240/DALI
10092117
360
30
21
DALI, Push-Dim
116
18
TC-L, TC-F
2
MLS39.1-2FR-11/220-240
10092026
280
30
21
-
112
18
TC-L
3
BCD18.3-4F-01/220-240/1-10V
10097171
360
39
21
1-10V
130
18
TC-L, TC-F
3
MLD14/24.3FR-04/220-240/DALI
10105150
360
39
22
DALI, Push-Dim
116
18
TC-L, TC-F
3
MLS14/24.3-4.FR-11/220-240
10095345
280
39
21
-
112
130
18
TC-L
4
BCD18.3-4F-01/220-240/1-10V
10097171
360
39
21
1-10V
18
TC-L, TC-F
4
MLD14/24.4FR-04/220-240/DALI
10105151
360
39
22
DALI, Push-Dim
116
18
TC-L, TC-F
4
MLS14/24.3-4.FR-11/220-240
10095345
280
39
21
-
112
154
24
TC-L, TC-F
1
BCD57.1/32.2Q-01/220-240/1-10V
10096387
103
67
30
1-10V
24
TC-L, TC-F
1
BCD57.1/32.2Q-01/220-240/DALI
10096397
103
67
30
DALI, Push-Dim
152
24
TC-L, TC-F
1
BCS39.1FX-11/220-240
10077581
280
30
21
-
120
24
TC-L, TC-F
1
BCS42.1/26.2LS-01/220-240
10095045
150
42
30
-
112
24
TC-L, TC-F
1
BCS42.1/26.2Q-01/220-240
10097545
103
67
30
-
136
140
24
TC-L, TC-F
1
BCS42.1/26.2QI-01/220-240
10095745
180
86
33
-
24
TC-L, TC-F
1
BCS42.1Q-01/220-240
10097535
103
67
30
-
134
24
TC-L, TC-F
1
EBS26.1C-01/220-240
10050992
80
41
19
-
148
24
TC-L, TC-F
1
EBS26.1M-01/220-240
10050996
150
22
22
-
148
24
TC-L, TC-F
1
MLD39.1FR-11/220-240/DALI
10097811
360
30
21
DALI, Push-Dim
116
24
TC-L, TC-F
1
MLS39.1-2FR-11/220-240
10092026
280
30
21
-
112
24
TC-L, TC-F
1
SCS42.1Q-01/220-240/4kV
166772
103
67
31
-
134
24
TC-L, TC-F
2
BCD57.1/32.2Q-01/220-240/1-10V
10096387
103
67
30
1-10V
154
24
TC-L, TC-F
2
BCD57.1/32.2Q-01/220-240/DALI
10096397
103
67
30
DALI, Push-Dim
152
24
TC-L, TC-F
2
BCS39.2FX-11/220-240
10077582
280
30
21
-
120
24
TC-L, TC-F
2
BCS42.1/26.2LS-01/220-240
10095045
150
42
30
-
112
24
TC-L, TC-F
2
BCS42.1/26.2Q-01/220-240
10097545
103
67
30
-
136
24
TC-L, TC-F
2
BCS42.1/26.2QI-01/220-240
10095745
180
86
33
-
140
24
TC-L, TC-F
2
MLD39.2FR-11/220-240/DALI
10092117
360
30
21
DALI, Push-Dim
116
112
24
TC-L, TC-F
2
MLS39.1-2FR-11/220-240
10092026
280
30
21
-
24
TC-L, TC-F
3
MLD14/24.3FR-04/220-240/DALI
10105150
360
39
22
DALI, Push-Dim
116
24
TC-L, TC-F
3
MLS14/24.3-4.FR-11/220-240
10095345
280
39
21
-
112
24
TC-L, TC-F
4
MLD14/24.4FR-04/220-240/DALI
10105151
360
39
22
DALI, Push-Dim
116
24
TC-L, TC-F
4
MLS14/24.3-4.FR-11/220-240
10095345
280
39
21
-
112
36
TC-L, TC-F
1
BCD36.1F-01/220-240/1-10V
10097144
360
30
21
1-10V
130
36
TC-L, TC-F
1
BCS38.1LS-01/220-240
10097427
150
42
30
-
112
36
TC-L, TC-F
1
BCS38.1Q-01/220-240
10097437
103
67
30
-
134
36
TC-L, TC-F
1
BCS39.1FX-11/220-240
10077581
280
30
21
-
120
36
TC-L, TC-F
1
BCS42.1Q-01/220-240
10097535
103
67
30
-
134
36
TC-L, TC-F
1
MLS39.1-2FR-11/220-240
10092026
280
30
21
-
112
36
TC-L, TC-F
2
BCD36.2F-01/220-240/1-10V
10097194
425
30
21
1-10V
130
36
TC-L, TC-F
2
BCD36.2Q-01/220-240/1-10V
10096326
103
67
30
-
156
36
TC-L, TC-F
2
BCS39.2FX-11/220-240
10077582
280
30
21
-
120
Product Catalogue 2014 | BAG electronics
Productfinder - Selection table
Power
Lamp
Number Description
of Lamps
Order No.
[W]
Lenght
X
Width
Y
Height
Z
[mm]
Interface
Page
[mm]
[mm]
36
TC-L, TC-F
2
MLS39.1-2FR-11/220-240
10092026
280
30
21
-
112
40
TC-L
1
BCD36.1F-01/220-240/1-10V
10097144
360
30
21
1-10V
130
154
40
TC-L
1
BCD57.1/32.2Q-01/220-240/1-10V
10096387
103
67
30
1-10V
40
TC-L
1
BCD57.1/32.2Q-01/220-240/DALI
10096397
103
67
30
DALI, Push-Dim
152
40
TC-L
1
BCS39.1FX-11/220-240
10077581
280
30
21
-
120
40
TC-L
1
BCS42.1/26.2LS-01/220-240
10095045
150
42
30
-
112
40
TC-L
1
BCS42.1/26.2Q-01/220-240
10097545
103
67
30
-
136
40
TC-L
1
BCS42.1/26.2QI-01/220-240
10095745
180
86
33
-
140
40
TC-L
1
BCS42.1Q-01/220-240
10097535
103
67
30
-
134
40
TC-L
1
MLD39.1FR-11/220-240/DALI
10097811
360
30
21
DALI, Push-Dim
116
40
TC-L
1
MLS39.1-2FR-11/220-240
10092026
280
30
21
-
112
130
40
TC-L
2
BCD36.2F-01/220-240/1-10V
10097194
425
30
21
1-10V
40
TC-L
2
BCS39.2FX-11/220-240
10077582
280
30
21
-
120
40
TC-L
2
MLD39.2FR-11/220-240/DALI
10092117
360
30
21
DALI, Push-Dim
116
40
TC-L
2
MLS39.1-2FR-11/220-240
10092026
280
30
21
-
112
55
TC-L
1
BCD55.1F-01/220-240/1-10V
10097079
360
30
21
1-10V
130
55
TC-L
1
BCS54.1FX-11/220-240
10077585
280
30
21
-
120
55
TC-L
1
BCS55.1Q-01/220-240/T5C
10097634
103
67
30
-
134
116
55
TC-L
1
MLD80.1FR-11/220-240/DALI
10097820
360
30
21
DALI, Push-Dim
55
TC-L
1
MLS80.1/54.2FR-11/220-240
10071609
280
30
21
-
112
55
TC-L
2
BCD55.2F-01/220-240/1-10V
10097089
425
30
21
1-10V
130
55
TC-L
2
BCS54.2FX-11/220-240
10077586
280
30
21
-
120
55
TC-L
2
MLD80.2FR-11/220-240/DALI
10101905
425
30
21
DALI, Push-Dim
116
55
TC-L
2
MLS80.1/54.2FR-11/220-240
10071609
280
30
21
-
112
80
TC-L
1
BCD80.1F-01/220-240/1-10V
10097249
360
30
21
1-10V
124
80
TC-L
1
BCS80.1FX-11/220-240
10077587
280
30
21
-
120
80
TC-L
1
MLD80.1FR-11/220-240/DALI
10097820
360
30
21
DALI, Push-Dim
116
80
TC-L
2
BCD80.2F-01/220-240/1-10V
10097299
425
30
21
1-10V
124
80
TC-L
2
MLD80.2FR-11/220-240/DALI
10101905
425
30
21
DALI, Push-Dim
116
TC-L/F
BAG electronics | Product Catalogue 2014
111
MLS EVO
Non-dimmable electronic control gear
for T5 and TC-L lamps with
Multi-Lamp-Technology
Electronic control gears (non-dimmable) | MLS EVO
Product information
• Multi-Lamp technology for automatic lamp recognition
and optimum operation of T5 and TC-L/F lamps
• Luminaire can be fitted with different lamps
(e.g. T5: 35W, 49W, 80W)
• Compact housing in slim design for space-saving
application in luminaires
Control gear for FL
• Energy-controlled electrode preserving lamp warm
start for maximum lamp life irrespective of switching
frequency; starting time < 1 s
• Cut-Off technology: minimised heat current through
electrodes during operation, for optimum light output
and reduced power loss.
    
Office & Commercial
    
Outdoor
    
Shop
    
Technical data
Conformity
EN 61347-1
Mains voltage supply
Rated voltage range
220 ... 240 [V]
EN 61347-2-3
Rated frequency
0 / 50 ... 60 [Hz]
EN 61347-2-3/C
Admissible continuous voltage range
(AC)
198 - 264 [V]
EN 60929
EN 61 00-3-2
Battery operation
Voltage range continuous DC
198 VDC - 278 VDC
Voltage short time DC min.
176 VDC
Overvoltage protection (time)
350V / 2 h
Max. leakage current
0.5 mA
EN 6100-3-3
EN 61547
EN 55015
• Automatic restart after lamp replacement
• Safety switch-off in case of abnormal lamp operation,
e. g. defective electrode and end of lamp life; tested
acc. to EN 61347-2-3 + Test 2
• Constant lamp output independent of mains voltage
fluctuations
• Optimum ignition safety even at low temperatures:
automatic second start if necessary
• Automatic restart after lamp replacement
• Suitable for direct current operation and emergency
lighting installations; complies with requirements for
emergency lighting according to EN 61347- 2-3/J
• Quick restart of lamps after short power disruptions
• Connecting earth can be disregarded in suitable
luminaires with safety classification II
• Energy efficiency EEI = A2BAT
• Nominal service life: 50.000 h with failure rate of
≤ 10% and operation at tc=tc,max
112
Industry
Product Catalogue 2014 | BAG electronics
Designations
Operating data
Lamp designation
W
W
A
kHz
MLS80.1FR-11/220-240
10071608
1 x T5 28
32
0.15
90
0.97
28
3
ENEC, EMV
1 x T5 35
39
0.18
90
0.97
35
3
ENEC, EMV
LS80.1/54.2FR-11/220-240
MLS39.1-2FR-11/220-240
MLS14/24.3-4.FR-11/
220-240
10071609
10092026
10095345
System rating
Input current
Operation
frequency
Power factor
Rated power
lamps
Picture
reference
Approval for
lamps
1 x T5 49
53.5
0.24
75
0.97
49
3
ENEC, EMV
1 x T5 54
60
0.27
42
0.97
54
3
ENEC, EMV
1 x T5 80
86
0.37
41
0.97
80
3
ENEC, EMV
1 x T5 28
32
0.15
67
0.93
28
23
ENEC, EMV
2 x T5 28
64
0.28
63
0.98
28
23
ENEC, EMV
1 x T5 35
39
0.18
66
0.95
35
23
ENEC, EMV
2 x T5 35
80
0.35
62
0.99
35
23
ENEC, EMV
1 x T5 49
55
0.24
57
0.97
49
23
ENEC, EMV
2 x T5 49
104
0.45
59
0.99
49
23
ENEC, EMV
1 x T5 54
60
0.26
47
0.98
54
23
ENEC, EMV
2 x T5 54
113
0.48
47
0.99
54
23
ENEC, EMV
1 x T5 80
86
0.37
46
0.99
80
23
ENEC, EMV
1 x TC-L 55
56
0.25
47
0.98
55
23
ENEC, EMV
2 x TC-L 55
105
0.43
47
0.99
55
23
ENEC, EMV
1 x T5 14
17
0.08
98
0.85
14
23
ENEC, EMV
2 x T5 14
33
0.15
86
0.93
14
23
ENEC, EMV
1 x T5 21
24.5
0.11
92
0.9
21
23
ENEC, EMV
2 x T5 21
48
0.20
82
0.97
21
23
ENEC, EMV
1 x T5 24
28
0.12
67
0.92
24
23
ENEC, EMV
2 x T5 24
54
0.23
66
0.97
24
23
ENEC, EMV
1 x T5 39
42
0.17
67
0.96
39
23
ENEC, EMV
2 x T5 39
82
0.35
66
0.98
39
23
ENEC, EMV
1 x TC-L 18
19
0.09
66
0.9
16
23
ENEC, EMV
2 x TC-L 18
35.5
0.15
67
0.94
16
23
ENEC, EMV
1 x TC-F 18
19
0.09
66
0.9
16
23
ENEC, EMV
2 x TC-F 18
35.5
0.15
67
0.94
16
23
ENEC, EMV
1 x TC-L 24
27
0.12
67
0.92
22
23
ENEC, EMV
2 x TC-L 24
50
0.23
67
0.97
22
23
ENEC, EMV
1 x TC-F 24
27
0.12
67
0.92
22
23
ENEC, EMV
2 x TC-F 24
50
0.23
67
0.97
22
23
ENEC, EMV
1 x TC-L 36
34.5
0.14
67
0.94
32
23
ENEC, EMV
2 x TC-L 36
69
0.29
67
0.98
32
23
ENEC, EMV
1 x TC-F 36
34.5
0.14
67
0.94
32
23
ENEC, EMV
2 x TC-F 36
69
0.29
67
0.98
32
23
ENEC, EMV
1 x TC-L 40
43.5
0.20
67
0.96
40
23
ENEC, EMV
2 x TC-L 40
88
0.38
67
0.98
40
23
ENEC, EMV
3 x T5 14 W
51
0.23
66 kHz
0.96
14
15, 66
ENEC, EMV
4 x T5 14 W
61
0.27
66 kHz
0.98
14
15, 66
ENEC, EMV
3 x T5 24 W
80
0.35
52 kHz
0.99
24
15, 66
ENEC, EMV
3 x TC-L 18 W
54
0.24
52 kHz
0.97
16
25, 29
ENEC, EMV
4 x TC-L 18 W
70
0.30
52 kHz
0.98
16
25, 29
ENEC, EMV
3 x TC-L 24 W
79
0.35
52 kHz
0.98
22
25, 29
ENEC, EMV
ENEC, EMV
4 x TC-L 24 W
98
0.43
52 kHz
0.99
22
25, 29
3 x T8 36 W
105
0.46
52 kHz
0.99
32
15
ENEC, EMV
4 x T5 24 W
98
0.43
52 kHz
0.99
24
15, 66
ENEC, EMV
BAG electronics | Product Catalogue 2014
Electronic control gears (non-dimmable) | MLS EVO
Materialnumber
Control gear for FL
Designation
113
Dimensions | weights | temperatures
Short designation
Length X
Width Y
Height Z
Hole spacing
XM (length
direction)
mm
mm
mm
mm
mm
MLS80.1FR-11
280
30
21
270
MLS80.1 / 54.2FR-11
280
30
21
MLS39.1-2FR-11
280
30
21
MLS14 / 24.3-4FR-11
280
39
21
Hole spacing
ZM (height
direction)
Diagram
Weight
kg
°C
°C
8.5
B
0.230
-25 ... 55
70
270
8.5
B
0.247
-25 ... 55
75
270
8.5
B
0.217
-25 ... 55
75
270
9
B
0.265
-20 ... 50
75
Case drawing
Y
Z
ZM
B
XM
X
Electronic control gears (non-dimmable) | MLS EVO
Wiring diagrams
3
25
1
2
3
4
Control gear for FL
1
2
3
4
5
6
7
8
9
10
1
2
9
10
1
2
3
4
5
6
7
8
9
10
15
1
2
3
4
5
6
7
8
9
10
1
2
9
10
23
1
2
3
4
5
6
66
1
2
9
10
114
1
2
9
10
1
2
3
4
5
6
7
8
9
10
Product Catalogue 2014 | BAG electronics
29
Ambient
temperature
ta
Housing
temperature
tc,max
BAG electronics | Product Catalogue 2014
115
Control gear for FL
Electronic control gears (non-dimmable) | MLS EVO
MLD EVO DALI
DALI dimmable electronic control gear for
T5 and TC-L lamps with
Multi-Lamp-Technology
Electronic control gears (dimmable) | MLD EVO DIM DALI
Product information
• Multi-Lamp technology for automatic lamp recognition
and optimum operation of T5 and TC-L/F lamps
• Twingle operation with 1 or 2 lamps*
• Luminaire can be fitted with different lamps
(e.g. T5: 35W, 49W, 80W)
Control gear for FL
• Compact housing in slim design for space-saving
application in luminaires
• Energy-controlled electrode preserving lamp warm
start for maximum lamp life irrespective of switching
frequency; starting time < 1 s
• Cut-Off technology: minimised heat current through
electrodes during operation, for optimum light output
and reduced power loss.
• Automatic restart after lamp replacement
• Safety switch-off in case of abnormal lamp operation,
e. g. defective electrode and end of lamp life;
tested acc. to EN 61347-2-3 + Test 2
Industry
    
Office & Commercial
    
Outdoor
    
Shop
    
Technical data
Conformity
EN 61347-1
Mains voltage supply
Rated voltage range
220 ... 240 [V]
EN 61347-2-3
Rated frequency
0 / 50 ... 60 [Hz]
EN 61347-2-3/C
Admissible continuous voltage range
(AC)
198 - 264 [V]
EN 60929
EN 62386-102
Battery operation
Voltage range continuous DC
198 VDC - 278 VDC
Voltage short time DC min.
176 VDC
Overvoltage protection (time)
350V / 2 h
Overvoltage protection DALI interface
264 V / permanent
Max. leakage current
0.5 mA
EN 61 00-3-2
EN 6100-3-3
EN 61547
EN 55015
Designations
• Constant lamp output independent of mains voltage
fluctuations
• Optimum ignition safety even at low temperatures:
automatic second start if necessary
• Automatic restart after lamp replacement
• Suitable for direct current operation and emergency
lighting installations; complies with requirements for
emergency lighting according to EN 61347- 2-3/J
• Quick restart of lamps after short power disruptions
• Connecting earth can be disregarded in suitable
luminaires with safety classification II
• Energy efficiency EEI = A2/A2BAT
• Nominal service life: 50.000 h with failure rate of
≤ 10% and operation at tc=tc,max
116
Product Catalogue 2014 | BAG electronics
push
Operating data
Lamp designation
W
W
A
kHz
MLD39.2FR-11/
220-240/DALI
10092117
2 x T5 14
33
0.15
69 ... 120
0.94
14
99
ENEC, EMV
2 x T5 21
45
0.20
72 ... 120
0.97
21
99
ENEC, EMV
MLD54.2FR-11/
220-240/DALI
MLD39.1FR-11/
220-240/DALI
MLD54.1FR-11/
220-240/DALI
MLD80.1FR-11/
220-240/DALI
MLD80.2FR-11/
220-240/DALI
MLD14/24.3FR-04
/220-240/DALI
MLD14/24.4FR-04
/220-240/DALI
10092121
10097811
10097815
10097820
10101905
10105150
10105151
System rating
Input current
Operation
frequency
Power factor
Rated power
lamps
Picture
reference
Approval for
lamps
2 x T5 24
49
0.22
40 ... 120
0.97
24
99
ENEC, EMV
2 x T5 39
79
0.35
40 ... 120
0.99
39
99
ENEC, EMV
2 x TC-F 18
36
0.16
40 ... 120
0.97
16
99
ENEC, EMV
2 x TC-F 24
48
0.22
40 ... 120
0.97
22
99
ENEC, EMV
2 x TC-L 18
36
0.16
40 ... 120
0.97
16
99
ENEC, EMV
2 x TC-L 24
48
0.22
40 ... 120
0.97
22
99
ENEC, EMV
2 x TC-L 40
85
0.37
40 ... 120
0.99
40
99
ENEC, EMV
2 x T5 28
63
0.28
40 ... 120
0.98
28
99
ENEC, EMV
2 x T5 35
78
0.34
40 ... 120
0.99
35
99
ENEC, EMV
2 x T5 49
104
0.45
40 ... 120
0.99
49
99
ENEC, EMV
2 x T5 54
115
0.51
40 ... 120
0.99
54
99
ENEC, EMV
1 x T5 14
17
0.09
99 ... 120
0.9
14
20. 28, 58
ENEC, EMV
1 x T5 21
22
0.11
96 ... 120
0.92
21
20. 28, 58
ENEC, EMV
1 x T5 24
28
0.13
69 ... 120
0.93
24
20. 28, 58
ENEC, EMV
1 x T5 39
39
0.18
71 ... 100
0.96
39
20. 28, 58
ENEC, EMV
1 x TC-F 18
19
0.09
64 ... 120
0.9
16
20. 28, 58
ENEC, EMV
1 x TC-F 24
26
0.12
69 ... 120
0.94
22
20. 28, 58
ENEC, EMV
1 x TC-L 18
19
0.09
64 ... 120
0.9
16
20. 28, 58
ENEC, EMV
1 x TC-L 24
26
0.12
69 ... 120
0.94
22
20. 28, 58
ENEC, EMV
1 x TC-L 40
41
0.18
73 ... 100
97
40
20. 28, 58
ENEC, EMV
1 x T5 28
33
0.16
90 ... 100
0.94
28
20. 28, 58
ENEC, EMV
1 x T5 35
40
0.17
87 ... 100
0.95
35
20. 28, 58
ENEC, EMV
1 x T5 49
55
0.25
79 ... 100
0.98
49
20. 28, 58
ENEC, EMV
1 x T5 54
56
0.27
52 ... 100
0.99
54
20. 28, 58
ENEC, EMV
1 x T5 35
39
0.17
88 ... 100
0.96
35
20. 28, 58
ENEC, EMV
1 x T5 49
55
0.25
79 ... 100
0.98
49
20. 28, 58
ENEC, EMV
1 x T5 80
81
0.38
45 ... 100
0.99
80
20. 28, 58
ENEC, EMV
1 x TC-L 55
68
0.28
46 ... 100
0.99
55
20. 28, 58
ENEC, EMV
1 x TC-L 80
83
0.38
45 ... 100
0.99
80
20. 28, 58
ENEC, EMV
2 x T5 35
77
0.34
42 ... 115
0.98
35
99, 28, 58
ENEC, EMV
2 x T5 49
101
0.46
42 ... 115
0.99
49
99, 28, 58
ENEC, EMV
2 x T5 80
177
0.74
42 ... 115
0.99
80
99, 28, 58
ENEC, EMV
2 x TC-L 55
125
0.47
42 ... 115
0.99
55
99, 28, 58
ENEC, EMV
2 x TC-L 80
177
0.74
42 ... 115
0.99
80
99, 28, 58
ENEC, EMV
3 x T5 14
49
0.22
42 ... 110
0.95
14
24, 55, 65
ENEC, EMV
3 x T5 24
77
0.35
42 ... 110
0.95
24
24, 55, 65
ENEC, EMV
3 x TC-L 18
50
0.23
42 ... 110
0.95
16
24, 55, 65
ENEC, EMV
3 x TC-L 24
75
0.34
42 ... 110
0.95
22
24, 55, 65
ENEC, EMV
3 x T8 18
58
0.27
42 ... 110
0.95
16
24, 55, 65
ENEC, EMV
4 x T5 14
63
0.29
42 ... 110
0.95
14
26, 55, 65
ENEC, EMV
ENEC, EMV
4 x T5 24
103
0.47
42 ... 110
0.95
24
26, 55, 65
4 x TC-L 18
71
0.32
42 ... 110
0.95
16
26, 55, 65
ENEC, EMV
4 x TC-L 24
100
0.46
42 ... 110
0.95
22
26, 55, 65
ENEC, EMV
4 x T8 18
75
0.34
42 ... 110
0.95
16
26, 55, 65
ENEC, EMV
Diagram
Weight
Ambient
temperature ta
kg
°C
°C
B, M
0.265
5 ... 55
75
Electronic control gears (dimmable) | MLD EVO DIM DALI
Materialnumber
Control gear for FL
Designation
Dimensions | weights | temperatures
Short designation
Length X
Width Y
Height Z
Hole spacing
XM (length
direction)
mm
mm
mm
mm
mm
MLD39.2FR-11
360
30
21
350
9
Hole spacing
ZM (height
direction)
Housing
temperature
tc,max
MLD54.2FR-11
360
30
21
350
9
B, M
0.318
5 ... 55
75
MLD39.1FR-11
360
30
21
350
9
B, M
0.270
5 ... 60
75
MLD54.1FR-11
360
30
21
350
9
B, M
0.275
5 ... 60
75
MLD80.1FR-01
360
30
21
350
9
B, M
0.275
5 ... 60
75
MLD80.2FR-11
425
30
21
415
9
B, M
0.366
5 ... 55
75
MLD14 / 24.3FR-04
360
39
22
350
-
B, M
0.370
5 ... 50
75
MLD14 / 24.4FR-04
360
39
22
350
-
B, M
0.380
5 ... 50
75
BAG electronics | Product Catalogue 2014
117
Case drawing
M
Y
Y
Z
Z
ZM
ZM
B
XM
X
XM
X
Wiring diagrams
20
28
Electronic control gears (dimmable) | MLD EVO DIM DALI
DA
DA
1
2
3
4
Push-DIM
L
N
PE L N
DA
DA
Push-DIM
L
N
DA
DALI
DA
24
▼ ▼ ▼ ▼ ▼
DA
DA
Push-DIM
L
N
1
2
3
4
55
5
6
PE L N
7
8
9
10
DA
DA
Push-DIM
L
N
26
DA
DA
Control gear for FL
Push-DIM
L
N
DA
DALI
DA
1
2
3
4
▼ ▼ ▼ ▼ ▼
5
6
58
PE L N
7
8
9
10
Taster
DA
DA
99
DA
DA
Push-DIM
L
N
1
2
3
4
5
6
7
▼ ▼ ▼
Push-DIM
L
N
▼
65
PE L N
Taster
DA
DA
▼ ▼ ▼
118
Product Catalogue 2014 | BAG electronics
▼
Push-DIM
L
N
BAG electronics | Product Catalogue 2014
119
Control gear for FL
Electronic control gears (dimmable) | MLD EVO DIM DALI
BCS PRIMUS T5
Non-dimmable electronic control gear for
T5 and TC-L/F lamps
Electronic control gears (non-dimmable) | BCS PRIMUS T5
Product information
• Short housing in flat design for space-saving
application in luminaires
• Multipower - Technology for operation with different
lamps on the same control gear
Control gear for FL
• Energy controlled, electrode preserving lamp warm
start for maximum lamp life irrespective of switching
frequency; starting time < 1,5 s
• Cut-Off technology: minimised heat current through
electrodes during operation, for optimum light output
and reduced power loss.
• Safety switch-off in case of abnormal lamp operation,
e. g. defective electrode and end of lamp life;
tested acc. to EN 61347-2-3 + Test 2
• Flimmer free light through high frequency lamp
operation, no stroboscope effect
• Constant lamp output independent of mains voltage
fluctuations
• Optimum ignition safety even at low temperatures:
automatic second start if necessary
• Automatic restart after lamp replacement
• Suitable for direct current operation and emergency
lighting installations; complies with requirements for
emergency lighting according to EN 61347- 2-3/J
• Quick restart of lamps after short power disruptions
• Connecting earth can be disregarded in suitable
luminaires with safety classification II
• Energy efficiency EEI= A2BAT
• Extended nominal service life*: 75.000 h at tc=tc,max
with failure rate of ≤ 10% 100.000 h operation at
tc=tc,max -10 K with failure rate ≤ 10 %
120
Product Catalogue 2014 | BAG electronics
Industry
    
Office & Commercial
    
Outdoor
    
Shop
    
Technical data
Conformity
EN 61347-1
Mains voltage supply
Rated voltage range
220 ... 240 [V]
EN 61347-2-3
Rated frequency
0 / 50 ... 60 [Hz]
EN 61347-2-3/C
Admissible continuous voltage range
(AC)
198 - 264 [V]
EN 60929
EN 61 00-3-2
Battery operation
Voltage range continuous DC
198 VDC - 278 VDC
Voltage short time DC min.
176 VDC
Overvoltage protection (time)
350 V / 2 h, 350V / 2h
Max. leakage current
0.5 mA
EN 6100-3-3
EN 61547
EN 55015
Designations
Operating data
Lamp designation
W
W
A
kHz
BCS14.3-4FR-01/220-240
10052868
3 x T5 14
47
0.22
50
0.96
14
52
ENEC, EMV
4 x T5 14
59
0.26
50
0.96
14
53
ENEC, EMV
BCS35.1FX-11/220-240
BCS35.2FX-11/220-240
BCS39.1FX-11/220-240
BCS39.2FX-11/220-240
10077579
10077580
10077581
10077582
System rating
Input
current
Operation
frequency
Power factor
Rated power
lamps
Picture
reference
Approval for
lamps
1 x T5 14
17
0.08
48
0.93
14
3
ENEC, EMV
1 x T5 21
24
0.10
48
0.96
21
3
ENEC, EMV
1 x T5 28
31
0.14
48
0.98
28
3
ENEC, EMV
1 x T5 35
39
0.17
48
0.99
35
3
ENEC, EMV
2 x T5 14
31
0.15
51
0.97
14
23
ENEC, EMV
2 x T5 21
47
0.21
51
0.97
21
23
ENEC, EMV
2 x T5 28
64
0.28
51
0.97
28
23
ENEC, EMV
2 x T5 35
74
0.34
51
0.97
35
23
ENEC, EMV
1 x T5 24
27
0.12
44
0.98
24
3
ENEC, EMV
1 x T5 39
41
0.18
44
0.97
39
3
ENEC, EMV
1 x T8 18
18
0.08
45
0.99
16
3
-
1 x T8 36
36
0.16
45
0.99
32
3
-
1 x TC-F 18
19
0.08
44
0.96
16
3
ENEC, EMV
1 x TC-F 24
26
0.12
44
0.98
22
3
ENEC, EMV
1 x TC-F 36
37
0.16
44
0.99
32
3
ENEC, EMV
1 x TC-L 18
19
0.08
44
0.96
16
3
ENEC, EMV
1 x TC-L 24
26
0.12
44
0.98
22
3
ENEC, EMV
1 x TC-L 36
37
0.16
44
0.99
32
3
ENEC, EMV
1 x TC-L 40
41
0.18
44
0.99
40
3
ENEC, EMV
2 x T5 24
53
0.24
42
0.98
24
23
ENEC, EMV
2 x T5 39
82
0.35
42
0.99
39
23
ENEC, EMV
2 x TC-L 18
34
0.15
42
0.96
16
23
ENEC, EMV
2 x TC-L 24
50
0.23
42
0.98
22
23
ENEC, EMV
2 x TC-L 36
67
0.29
42
0.99
32
23
ENEC, EMV
2 x TC-L 40
86
0.35
42
0.99
40
23
ENEC, EMV
2 x TC-F 18
34
0.15
42
0.96
16
23
ENEC, EMV
2 x TC-F 24
50
0.23
42
0.98
22
23
ENEC, EMV
2 x TC-F 36
67
0.29
42
0.99
32
23
ENEC, EMV
BCS49.1FX-11/220-240
10077583
1 x T5 49
54
0.23
52
0.99
49
3
ENEC, EMV
BCS49.2FX-11/220-240
10077584
2 x T5 49
109
0.48
52
0.99
49
23
ENEC, EMV
BCS54.1FX-11/220-240
10077585
1 x T5 54
59
0.26
49
0.99
54
3
ENEC, EMV
1 x T8 58
55
0.25
49
0.99
58
3
ENEC, EMV
1 x TC-L 55
59
0.26
49
0.99
55
3
ENEC, EMV
BCS54.2FX-11/220-240
10077586
2 x T5 54
107
0.47
46
0.99
54
23
ENEC, EMV
2 x TC-L 55
108
0.47
46
0.99
55
23
ENEC, EMV
BCS80.1FX-11/220-240
10077587
1 x T5 80
87
0.38
47
0.99
80
3
ENEC, EMV
1 x TC-L 80
87
0.38
47
0.99
80
3
ENEC
Electronic control gears (non-dimmable) | BCS PRIMUS T5
Materialnumber
Control gear for FL
Designation
Dimensions | weights | temperatures
Short designation
Length X
Width Y
Height Z
Hole spacing
XM (length
direction)
mm
mm
mm
mm
mm
BCS14.3-4FR-01
280
42
21
270
BCS35.1FX-11
280
30
21
BCS35.2FX-11
280
30
21
BCS39.1FX-11
280
30
BCS39.2FX-11
280
BCS49.1FX-11
Hole spacing
ZM (height
direction)
Diagram
Weight
Ambient
temperature ta
Housing
temperature
tc,max
kg
°C
°C
9
B
0.250
-20 ... 60
70
270
9
B
0.177
-20 ... 60
75
270
9
B
0.205
-20 ... 55
70
21
270
9
B
0.174
-20 ... 60
75
30
21
270
9
B
0.192
-20 ... 55
75
280
30
21
270
9
B
0.184
-20 ... 60
70
BCS49.2FX-11
280
30
21
270
9
B
0.221
-20 ... 55
75
BCS54.1FX-11
280
30
21
270
9
B
0.185
-20 ... 60
75
BCS54.2FX-01
280
30
21
270
9
B
0.204
-20 ... 55
80
BCS80.1FR-01
280
30
21
270
9
B
0.189
-20 ... 55
75
BAG electronics | Product Catalogue 2014
121
Case drawing
Y
Z
Zm
B
Xm
X
Wiring diagrams
3
Electronic control gears (non-dimmable) | BCS PRIMUS T5
Control gear for FL
122
1
2
3
4
23
1
2
3
4
5
6
52
1
2
7
8
9
10
1
2
3
4
5
6
53
1
2
7
8
9
10
1
2
3
4
5
6
Product Catalogue 2014 | BAG electronics
BAG electronics | Product Catalogue 2014
123
Control gear for FL
Electronic control gears (non-dimmable) | BCS PRIMUS T5
BCD T5 1-10V
Dimmable electronic control gear for T5
lamps
Electronic control gears (dimmable) | BCD T5 1-10V
Product information
• Dimming interface: 1–10 V
• Dimming range 1...100% luminous flux
• Energy controlled, electrode preserving lamp warm
start for maximum lamp life irrespective of switching
frequency; starting time < 1,5 s
Control gear for FL
• Cut-Off technology at 100% luminous flux: minimised
heat current through electrodes during operation,
for optimum light output and reduced power loss.
• Automatic restart after lamp replacement
• Safety switch-off in case of abnormal lamp operation,
e. g. defective electrode and end of lamp life;
tested acc. to EN 61347-2-3
• Suitable for direct current operation and emergency
lighting installations; complies with requirements for
emergency lighting according to EN 61347- 2-3/J
• Energy efficiency index EEI=A1
• Nominal service life: 50.000 h with failure rate of ≤ 10%
and operation at tc=tc,max
124
Product Catalogue 2014 | BAG electronics
Industry
    
Office & Commercial
    
Outdoor
    
Shop
    
Technical data
Conformity
EN 61347-1
Mains voltage supply
Rated voltage range
220 ... 240 [V]
EN 61347-2-3
Rated frequency
0 / 50 ... 60 [Hz]
EN 61347-2-3/C
Admissible continuous voltage range
(AC)
198 ... 264 [V]
EN 60929
EN 61 00-3-2
Battery operation
Voltage range continuous DC
198 VDC - 278 VDC
Voltage short time DC min.
176 VDC
Overvoltage protection (time)
350V / 2 h
Max. leakage current
0.5 mA
Max. control current (1-10V)
0.2 mA
EN 6100-3-3
EN 61547
EN 55015
Designations
Operating data
Materialnumber
Lamp designation
W
W
A
kHz
BCD35.1F-01/
220-240/1-10V
10097244
1 x T5 14
18
0.08
50 ... 85
0.96
14
64
ENEC
1 x T5 21
25
0.12
50 ... 85
0.96
21
64
ENEC
10097246
BCD49.1F-01/
220-240/1-10V
Input current
Operation
frequency
Power factor
Rated power
lamps
Picture
reference
Approval for
lamps
1 x T5 28
32
0.15
50 ... 85
0.96
28
64
ENEC
1 x T5 35
39
0.19
50 ... 85
0.96
35
64
ENEC
1 x T5 24
26
0.12
45 ... 105
0.98
24
64
ENEC
1 x T5 39
38.5
0.17
45 ... 105
0.98
39
64
ENEC
10097247
1 x T5 49
55
0.24
55 ... 80
0.97
49
64
ENEC
BCD54.1F-01/
220-240/1-10V
10097248
1 x T5 54
58
0.26
55 ... 120
0.97
54
64
ENEC
BCD80.1F-01/
220-240/1-10V
10097249
BCD14.3F-01/
220-240/1-10V
1 x T5 80
86
0.37
45 ... 115
0.98
80
64
ENEC
1 x TC-L 80
86
0.37
45 ... 115
0.98
80
64
ENEC
10097281
3 x T5 14
50
0.22
56 ... 66
0.95
14
76
ENEC
BCD14.4F-01/
220-240/1-10V
10097291
4 x T5 14
66
0.29
48 ... 80
0.95
14
75
ENEC
BCD35.2F-01/
220-240/1-10V
10097294
BCD39.2F-01/
220-240/1-10V
10097296
BCD49.2F-01/
220-240/1-10V
2 x T5 14
34
0.15
45 ... 90
0.97
14
74
ENEC
2 x T5 21
48
0.21
45 ... 90
0.97
21
74
ENEC
2 x T5 28
64
0.28
45 ... 90
0.97
28
74
ENEC
2 x T5 35
78
0.35
45 ... 90
0.97
35
74
ENEC
2 x T5 24
53
0.23
40 ... 110
0.97
24
74
ENEC
2 x T5 39
78
0.34
40 ... 110
0.97
39
74
ENEC
10097297
2 x T5 49
106
0.47
50 ... 90
0.98
49
74
ENEC
BCD54.2F-01/
220-240/1-10V
10097298
2 x T5 54
115
0.51
40 ... 145
0.97
54
74
ENEC
BCD80.2F-01/
220-240/1-10V
10097299
2 x T5 80
172
0.75
45 ... 120
0.97
80
74
ENEC
2 x TC-L 80
172
0.75
45 ... 120
0.97
80
74
ENEC
Dimensions | weights | temperatures
Short designation
Length X
Width Y
Height Z
Hole spacing
XM (length
direction)
mm
mm
mm
mm
mm
BCD35.1F-01
360
30
21
350
BCD39.1F-01
360
30
21
BCD49.1F-01
360
30
21
BCD54.1F-01
360
30
BCD80.1F-01
360
30
BCD14.3F-01
360
BCD14.4F-01
BCD35.2F-01
Hole spacing
ZM (height
direction)
Diagram
Weight
Ambient
temperature
ta
kg
°C
°C
9
M
0.250
5 ... 55
75
350
9
M
0.246
5 ... 55
70
350
9
M
0.252
5 ... 55
70
21
350
9
M
0.262
5 ... 55
70
21
350
9
M
0.262
5 ... 55
70
39
21
350
9
M
0.325
5 ... 60
75
360
39
21
350
9
M
0.317
5 ... 60
75
420
30
20
415
9
M
0.328
5 ... 55
75
BCD39.2F-01
425
30
21
415
9
M
0.328
5 ... 55
70
BCD49.2F-01
425
30
21
415
9
M
0.356
5 ... 55
70
BCD54.2F-01
425
30
21
415
9
M
0.330
5 ... 55
75
BCD80.2F-01
425
30
21
415
9
M
0.386
5 ... 55
75
Housing
temperature
tc,max
Control gear for FL
BCD39.1F-01/
220-240/1-10V
System rating
Electronic control gears (dimmable) | BCD T5 1-10V
Designation
Case drawing
Y
Z
ZM
M
XM
X
BAG electronics | Product Catalogue 2014
125
Wiring diagrams
64
1
2
3
4
1−10 V
74
1−10 V
Electronic control gears (dimmable) | BCD T5 1-10V
Control gear for FL
126
1
2
3
4
5
6
7
75
17
16
15
14
n.c.
1
2
3
4
5
6
7
+
1-10V
–
76
17
16
15
14
n.c.
1
2
3
4
5
6
7
+
1-10V
–
Product Catalogue 2014 | BAG electronics
BAG electronics | Product Catalogue 2014
127
Control gear for FL
Electronic control gears (dimmable) | BCD T5 1-10V
BCS PRIMUS T8
Non-dimmable electronic control gear for
T8 lamps
Electronic control gears (non-dimmable) | BCS PRIMUS T8
Product information
• Short housing in flat design for space-saving application in luminaires
• Energy controlled, electrode preserving lamp warm
start for maximum lamp life irrespective of switching
frequency; starting time < 1,5 s
Control gear for FL
• Cut-Off technology: minimised heat current through
electrodes during operation, for optimum light output
and reduced power loss.
• Safety switch-off in case of abnormal lamp operation,
e. g. defective electrode and end of lamp life; tested acc.
to EN 61347-2-3 + Test 2
• Flimmer free light through high frequency lamp
operation, no stroboscope effect
• Constant lamp output independent of mains voltage
fluctuations
• Optimum ignition safety even at low temperatures:
automatic second start if necessary
• Automatic restart after lamp replacement
• Suitable for direct current operation and emergency
lighting installations; complies with requirements for
emergency lighting according to EN 61347- 2-3/J
• Constant light output irrespective of mains power
fluctuation
• Quick restart of lamps after short power disruptions
• Connecting earth can be disregarded in suitable luminaires with safety classification II
• Energy efficiency EEI= A2BAT
• Extended nominal service life*: 75.000 h at tc=tc,max
with failure rate of ≤ 10% 100.000 h operation at
tc=tc,max -10 K with failure rate ≤ 10 %
128
Product Catalogue 2014 | BAG electronics
Industry
    
Office & Commercial
    
Outdoor
    
Shop
    
Technical data
Conformity
EN 61347-1
Mains voltage supply
Rated voltage range
220 ... 240 [V]
EN 61347-2-3
Rated frequency
0 / 50 ... 60 [Hz]
EN 61347-2-3/C
Admissible continuous voltage range
(AC)
198 - 264 [V]
EN 60929
EN 61 00-3-2
Battery operation
Voltage range continuous DC
198 VDC - 278 VDC
Voltage short time DC min.
176 VDC
Overvoltage protection (time)
350V /2 h
Max. leakage current
0.5 mA
EN 6100-3-3
EN 61547
EN 55015
Designations
Operating data
Designation
Material
number
Lamp designation
System rating
Input current
Operation
frequency
Power factor
Rated
power lamps
Picture
reference
Approval for
lamps
W
W
A
kHz
BCS18.3-4LR-01/220-240
10050999
3 x T8 18
58
0.26
47
0.98
16
50
ENEC, EMV
4 x T8 18
76
0.33
47
0.99
16
51
ENEC, EMV
BCS18.1FX-11/220-240
10077588
1 x T8 18
19
0.08
49
0.97
16
3
ENEC, EMV
BCS18.2FX-11/220-240
10077589
2 x T8 18
36
0.16
45
0.97
16
23
ENEC, EMV
BCS36.1FX-11/220-240
10077590
1 x T8 36
35
0.16
44
0.97
32
3
ENEC, EMV
BCS36.2FX-11/220-240
10077591
2 x T8 36
71
0.32
45
0.99
32
23
ENEC, EMV
BCS58.1FX-11/220-240
10077592
1 x T8 58
55
0.25
45
0.99
58
3
ENEC, EMV
BCS58.2FX-11/220-240
10077593
2 x T8 58
108
0.50
45
0.99
58
23
ENEC, EMV
Short designation
Length X
Width Y
Height Z
Hole spacing
XM (length
direction)
mm
mm
mm
mm
mm
BCS18.3-4LR-01
290
42
28
280
BCS18.1FX-11
280
30
21
BCS18.2FX-11
280
30
21
BCS36.1FX-11
280
30
BCS36.2FX-11
280
30
BCS58.1FX-11
280
BCS58.2FX-11
280
Hole spacing
ZM (height
direction)
Diagram
Weight
Ambient
temperature
ta
kg
°C
°C
-
B
0.270
-20 ... 60
75
265
9
B
0.183
-20 ... 60
75
265
9
B
0.177
-20 ... 60
75
21
265
9
B
0.183
-20 ... 60
75
21
265
9
B
0.191
-20 ... 60
75
30
21
265
9
B
0.185
-20 ... 60
75
30
21
265
9
B
0.209
-20 ... 55
75
Housing
temperature
tc,max
Case drawing
Y
Z
ZM
B
Electronic control gears (non-dimmable) | BCS PRIMUS T8
Dimensions | weights | temperatures
XM
Control gear for FL
X
Wiring diagrams
3
50
1
2
3
4
5
6
7
8
9
10
23
1
2
3
4
5
6
1
2
3
4
5
6
51
5
6
7
8
9
10
1
2
3
4
5
6
BAG electronics | Product Catalogue 2014
129
BCD T8 1-10V
Dimmable electronic control gear for
T8- and TC-L/F lamps
Electronic control gears (dimmable) | BCD T8 1-10V
Product information
• Dimming interface: 1–10 V
• Dimming range 1...100% luminous flux
• Multi-Power technology for operation of different lamps
and wattages on the same ECG
Control gear for FL
• Electrode preserving warm start for maximum lamp life,
even at increased switching frequency;
starting time < 1.5 s
    
Office & Commercial
    
Outdoor
    
Shop
    
Technical data
Conformity
EN 61347-1
Mains voltage supply
Rated voltage range
220 ... 240 [V]
EN 61347-2-3
Rated frequency
0 / 50 ... 60 [Hz]
EN 61347-2-3/C
Admissible continuous voltage range
(AC)
198 - 264 [V]
EN 60929
EN 61 00-3-2
Battery operation
Voltage range continuous DC
198 VDC - 278 VDC
Voltage short time DC min.
176 VDC
• Cut-Off technology at 100% luminous flux: minimised
heat current through electrodes during operation, for
optimum light output and reduced power loss.
Overvoltage protection (time)
350 V / 2 h
• Automatic restart after lamp replacement
Max. leakage current
0.5 mA
Max. control current (1-10V)
0.2 mA
• Safety switch-off in case of abnormal lamp operation,
e. g. defective electrode and end of lamp life; tested acc.
to EN 61347-2-3
• Suitable for direct current operation and emergency
lighting installations; complies with requirements for
emergency lighting according to EN 61347- 2-3/J
• Energie efficiency EEI=A1
• Nominal service life: 50.000 h with failure rate of
≤ 10% and operation at tc=tc,max
130
Industry
Product Catalogue 2014 | BAG electronics
EN 6100-3-3
EN 61547
EN 55015
Designations
Material
number
Lamp designation
W
W
A
kHz
BCD55.1F-01/
220-240/1-10V
10097079
1 x TC-L 55
59
0.27
BCD55.2F-01/
220-240/1-10V
10097089
2 x TC-L 55
122
0.54
BCD18.1F-01/
220-240/1-10V
10097143
BCD36.1F-01/
220-240/1-10V
10097144
BCD58.1F-01/
220-240/1-10V
10097145
BCD18.3-4F-01/
220-240/1-10V
10097171
System rating
Input current
Operation
frequency
Power factor
Rated power
lamps
Picture
reference
Approval for
lamps
45 ... 120
0.98
55
64
ENEC
50 ... 140
0.98
55
74
ENEC
ENEC
1 x T8 18
19
0.09
50 ... 100
0.96
16
64
1 x T8 30
30
0.13
50 ... 100
0.96
30
64
45 ... 90
1 x T8 36
36
0.16
1 x TC-F 36
36
0.16
0.98
32
64
ENEC
0.98
32
64
ENEC
1 x TC-L 36
36
0.21
0.98
32
64
ENEC
1 x TC-L 40
46
0.21
45 ... 90
0.98
40
64
ENEC
1 x T8 58
57
0.25
50 ... 110
0.97
58
64
ENEC
3 x T5 24
76
0.33
47 ... 75
0.95
24
76
ENEC
3 x T8 18
47
0.25
47 ... 75
0.95
16
76
ENEC
3 x TC-L 18
57
0.25
47 ... 75
0.95
16
76
ENEC
4 x T8 18
74
0.32
47 ... 75
0.95
16
77
ENEC
4 x TC-L 18
74
0.32
47 ... 75
0.95
16
77
ENEC
BCD18.2F-01/
220-240/1-10V
10097193
2 x T8 18
39
0.17
45 ... 140
0.97
16
74
ENEC
2 x T8 30
58
0.26
45 ... 140
0.97
30
74
BCD36.2F-01/
220-240/1-10V
10097194
2 x T8 36
74
0.31
40 ... 110
0.97
32
74
ENEC
2 x TC-F 36
74
0.31
40 ... 110
0.97
32
74
ENEC
BCD58.2F-01/
220-240/1-10V
10097195
2 x TC-L 36
74
0.31
40 ... 110
0.97
32
74
ENEC
2 x TC-L 40
89
0.38
40 ... 110
0.97
40
74
ENEC
2 x T8 58
110
0.48
40 ... 145
0.97
58
74
ENEC
Dimensions | weights | temperatures
Short designation
Length X
Width Y
Height Z
Hole spacing
XM (length
direction)
mm
mm
mm
mm
mm
BCD55.1F-01
360
30
21
350
BCD55.2F-01
425
30
21
BCD18.1F-01
360
30
21
BCD36.1F-01
360
30
BCD58.1F-01
360
BCD18.3-4F-01
Hole spacing
ZM (height
direction)
Diagram
Weight
Ambient
temperature ta
Housing
temperature
tc,max
kg
°C
°C
9
M
0.250
5 ... 55
70
415
9
M
0.355
5 ... 55
70
350
9
M
0.246
5 ... 55
70
21
350
9
M
0.250
5 ... 55
70
30
21
350
9
M
0.260
5 ... 55
70
360
39
21
350
9
M
0.310
5 ... 60
75
BCD18.2F-01
425
30
21
415
9
M
0.325
5 ... 55
70
BCD36.2F-01
425
30
21
415
9
M
0.328
5 ... 55
75
BCD58.2F-01
425
30
21
415
9
M
0.330
5 ... 55
75
Control gear for FL
Designation
Electronic control gears (dimmable) | BCD T8 1-10V
Operating data
Case drawing
Y
Z
Zm
M
Xm
X
BAG electronics | Product Catalogue 2014
131
Wiring diagrams
64
1
2
3
4
1−10 V
74
1−10 V
Electronic control gears (dimmable) | BCD T8 1-10V
Control gear for FL
132
1
2
3
4
5
6
7
76
17
16
15
14
n.c.
1
2
3
4
5
6
7
+
1-10V
–
77
17
16
15
14
n.c.
1
2
3
4
5
6
7
+
1-10V
–
Product Catalogue 2014 | BAG electronics
BAG electronics | Product Catalogue 2014
133
Control gear for FL
Electronic control gears (dimmable) | BCD T8 1-10V
BCS TC
Non-dimmable electronic control gear for
CFL, T5 and T8 lamps
Electronic control gears (non-dimmable) | BCS TC
Product information
• All models in compact housing for space-saving
application in luminaires
• Multi-Power technology for operation of different lamps
and wattages on the same ECG
Control gear for FL
• Electrode preserving warm start for maximum lamp life,
even at increased switching frequency;
starting time
< 1.5 s
• Cut-Off technology: minimised heat current through
electrodes during operation, for optimum light output
and reduced power loss.
• Safety switch-off in case of abnormal lamp operation,
e. g. defective electrode and end of lamp life; tested acc.
to EN 61347-2-3 + Test 2
• Suitable for direct current operation and emergency
lighting installations; complies with requirements for
emergency lighting according to EN 61347- 2-3/J
• Constant lamp output independent of mains voltage
fluctuations
• Optimum ignition safety even at low temperatures:
automatic second start if necessary
• Automatic restart after lamp replacement
• Suitable for direct current operation and emergency
lighting installations; complies with requirements for
emergency lighting according to EN 61347- 2-3/J
• Quick restart of lamps after short power disruptions
• Connecting earth can be disregarded in suitable
luminaires with safety classification II
• Energy efficiency EEI=A2
• Nominal service life: 50.000 h with failure rate of
≤ 10% and operation at tc=tc,max
134
Product Catalogue 2014 | BAG electronics
Industry
    
Office & Commercial
    
Outdoor
    
Shop
    
Technical data
Conformity
EN 61347-1
Mains voltage supply
Rated voltage range
220 ... 240 [V]
EN 61347-2-3
Rated frequency
0 / 50 ... 60 [Hz]
EN 61347-2-3/C
Admissible continuous voltage range
(AC)
198 - 264 [V]
EN 60929
EN 61 00-3-2
Battery operation
Voltage range continuous DC
198 VDC - 278 VDC
Voltage short time DC min.
176 VDC
Overvoltage protection (time)
350 V / 2 h
Max. leakage current
0.5 mA
EN 6100-3-3
EN 61547
EN 55015
Designations
Operating data
Lamp designation
System rating
Input current
Operation
frequency
Power factor
Rated power
lamps
Picture
reference
Approval for
lamps
W
W
A
kHz
BCS28.1Q-01/220-240
10097436
1 x TC-DD 28
28
0.12
45
0.97
28
11
ENEC
BCS38.1Q-01/220-240
10097437
1 x TC-DD 38
38
0.17
42
0.98
38
11
ENEC
1 x TC-F 36
37
0.16
42
0.98
32
11
ENEC
1 x TC-L 36
37
0.16
42
0.98
32
11
ENEC
BCS55.1Q-01/220-240/
10097439
1 x TC-DD 55
58
0.25
45
0.95
55
11
ENEC
BCS18.1Q-01/220-240
10097534
1 x TC-DEL 18
18
0.08
45
0.95
16
11
ENEC, EMV
1 x TC-TEL 18
18
0.08
45
0.95
16
11
ENEC, EMV
BCS42.1Q-01/220-240
10097535
1 x T12 40
42
0.19
45
0.96
40
11
-
1 x T5C 22
24
0.11
45
0.96
22
11
ENEC, EMV
1 x T5C 40
42
0.19
45
0.96
40
11
ENEC, EMV
1 x T5 24
27
0.12
45
0.96
24
11
-
1 x T5 39
38
0.17
45
0.96
39
11
-
1 x T8 15
18
0.08
45
0.96
14
11
-
1 x T8 18
19
0.09
45
0.96
16
11
-
1 x T8 36
35
0.16
45
0.96
32
11
-
1 x T8 38
37
0.17
45
0.96
32
11
-
1 x TC-DEL 26
27
0.12
45
0.96
24
11
ENEC, EMV
1 x TC-F 18
18
0.08
45
0.96
16
11
ENEC, EMV
1 x TC-F 24
24
0.11
45
0.96
22
11
ENEC, EMV
1 x TC-F 36
35
0.16
45
0.96
32
11
ENEC, EMV
1 x TC-L 18
18
0.08
45
0.96
16
11
ENEC, EMV
1 x TC-L 24
24
0.11
45
0.96
22
11
ENEC, EMV
1 x TC-L 36
35
0.16
45
0.96
32
11
ENEC, EMV
1 x TC-L 40
42
0.19
45
0.96
40
11
ENEC, EMV
1 x TC-TEL 26
27
0.12
45
0.96
24
11
ENEC, EMV
1 x TC-TEL 32
35
0.16
45
0.96
32
11
ENEC, EMV
1 x TC-TEL 42
46
0.21
45
0.96
42
11
ENEC, EMV
BCS55.1Q-01/220-240/T5C
10097634
1 x T5C 55
59
0.26
45
0.98
55
11
ENEC, EMV
1 x TC-L 55
59
0.26
45
0.98
55
11
ENEC, EMV
BCS60.1Q-01/220-240
10097635
1 x T5C 60
64
0.28
48
0.98
60
11
ENEC, EMV
SCS42.1Q-01/220-240/4kV
166772
1 x TC-DEL 26
27
0.12
45
0.94
24
11
ENEC, EMV
1 x TC-F 18
19
0.11
45
0.87
16
11
VDE, EMV
1 x TC-F 24
25
0.11
45
0.92
22
11
VDE, EMV
1 x TC-L 18
19
0.11
45
0.87
16
11
VDE, EMV
1 x TC-L 24
25
0.11
45
0.92
22
11
VDE, EMV
1 x TC-TEL 26
27
0.12
45
0.94
24
11
ENEC, EMV
1 x TC-TEL 32
36
0.16
45
0.96
32
11
ENEC, EMV
1 x TC-TEL 42
46
0.20
45
0.98
42
11
ENEC, EMV
Electronic control gears (non-dimmable) | BCS TC
Material
number
Control gear for FL
Designation
Dimensions | weights | temperatures
Short designation
Length X
Width Y
Height Z
Hole spacing
XM (length
direction)
Hole spacing
YM (width
direction)
Hole spacing
ZM (height
direction)
Diagram
Weight
Ambient
temperature
ta
Housing
temperature
tc,max
°C
mm
mm
mm
mm
mm
mm
kg
°C
BCS28.1Q-01
103
67
30
94
57
28
G
0.118
-20 ... 60
75
BCS38.1Q-01
103
67
30
94
57
28
G
0.118
-20 ... 60
75
BCS55.1Q-01
103
67
30
94
57
28
G
0.118
-20 ... 50
75
BCS18.1Q-01
103
67
30
94
57
28
G
0.112
-20 ... 60
75
BCS42.1Q-01
103
67
30
94
57
28
G
0.112
-20 ... 60
75
BCS60.1Q-01
103
67
30
94
57
28
G
0.146
-20 ... 50
70
SCS42.1Q-01
103
67
31
94
57
28
G
0.145
-20 ... 55
80
Case drawing
11
ZM
Z
X1
YM
Y
G
Wiring diagrams
XM
X
1
2
3
4
BAG electronics | Product Catalogue 2014
135
BCS TC Twingle
Non-dimmable electronic control gear for
CFL, T5 and T8 lamps with TwingleTechnology
Electronic control gears (non-dimmable) | BCS TC Twingle
Product information
• All models in compact housing for space-saving
application in luminaires
• Multi-Power technology for operation of different lamps
and wattages on the same ECG
• Twingle function: operation with 1 or 2 lamps
Control gear for FL
• Electrode preserving warm start for maximum lamp life,
even at increased switching frequency;
starting time < 1.5 s
• Cut-Off technology: minimised heat current through
electrodes during operation, for optimum light output
and reduced power loss.
• Safety switch-off in case of abnormal lamp operation,
e. g. defective electrode and end of lamp life; tested acc.
to EN 61347-2-3 + Test 2
• Constant lamp output independent of mains voltage
fluctuations
• Optimum ignition safety even at low temperatures:
automatic second start if necessary
• Automatic restart after lamp replacement
• Suitable for direct current operation and emergency
lighting installations; complies with requirements for
emergency lighting according to EN 61347- 2-3/J
• Quick restart of lamps after short power disruptions
• Connecting earth can be disregarded in suitable
luminaires with safety classification II
• Energy efficiency EEI=A2
• Nominal service life: 50.000 h with failure rate of
≤ 10% and operation at tc=tc,max
136
Product Catalogue 2014 | BAG electronics
Industry
    
Office & Commercial
    
Outdoor
    
Shop
    
Technical data
Conformity
EN 61347-1
Mains voltage supply
Rated voltage range
220 ... 240 [V]
EN 61347-2-3
Rated frequency
0 / 50 ... 60 [Hz]
EN 61347-2-3/C
Admissible continuous voltage range
(AC)
198 - 264 [V]
EN 60929
EN 61 00-3-2
Battery operation
Voltage range continuous DC
198 VDC - 278 VDC
Voltage short time DC min.
176 VDC
Overvoltage protection (time)
350 V / 2 h
Max. leakage current
0.5 mA
EN 6100-3-3
EN 61547
EN 55015
Designations
Operating data
Lamp designation
W
W
A
kHz
BCS21.1-2Q-01/220-240
10097543
1 x T5 14
15
0.07
50
0.9
14
31
-
1 x T5 21
22
0.10
50
0.9
21
31
-
BCS18.1-2Q-01/220-240
10097544
BCS42.1/26.2Q-01/220-240 10097545
BCS70.1/42.2Q-01/220-240 10097546
System rating
Input current
Operation
frequency
Power factor
Rated power
lamps
Picture
reference
Approval for
lamps
1 x TC-DD 10
12
0.05
50
0.9
10
31
-
1 x TC-DD 16
17
0.07
50
0.9
16
31
-
1 x TC-DEL 10
12
0.05
50
0.9
10
31
ENEC
1 x TC-DEL 13
14
0.07
50
0.9
13
31
ENEC
1 x TC-SE 9
11
0.05
50
0.9
9
31
ENEC
1 x TC-SE 11
13
0.06
50
0.9
11
31
ENEC
1 x TC-TEL 13
14
0.07
50
0.9
13
31
ENEC
2 x T5 14
28
0.13
50
0.9
14
31
-
2 x TC-DD 10
21
0.10
50
0.9
10
31
-
2 x TC-DD 16
29
0.14
50
0.9
16
31
-
2 x TC-DEL 10
21
0.10
50
0.9
10
31
ENEC
2 x TC-DEL 13
27
0.13
50
0.9
13
31
ENEC
2 x TC-SE 9
20
0.09
50
0.9
9
31
ENEC
2 x TC-SE 11
25
0.12
50
0.9
11
31
ENEC
2 x TC-TEL 13
27
0.13
50
0.9
13
31
ENEC
1 x TC-DEL 18
19
0.08
41
0.95
16
31
ENEC, EMV
1 x TC-TEL 18
19
0.08
41
0.95
16
31
ENEC, EMV
2 x TC-DEL 18
37
0.17
41
0.95
16
31
ENEC, EMV
2 x TC-TEL 18
37
0.17
41
0.95
16
31
ENEC, EMV
1 x T12 40
37
0.17
45
0.95
40
31
-
1 x T5C 22
24
0.11
45
0.95
22
31
ENEC, EMV
1 x T5C 40
42
0.19
45
0.95
40
31
ENEC, EMV
1 x T5 24
26
0.12
45
0.95
24
31
-
1 x T5 39
40
0.17
45
0.95
39
31
-
1 x T8 15
17
0.08
45
0.95
14
31
-
1 x T8 18
19
0.09
45
0.95
16
31
-
1 x T8 36
36
0.16
45
0.95
32
31
-
1 x T8 38
37
0.17
45
0.95
32
31
-
1 x TC-DEL 26
26
0.12
45
0.95
24
31
ENEC, EMV
1 x TC-F 18
18
0.08
45
0.95
16
31
ENEC, EMV
1 x TC-F 24
24
0.11
45
0.95
22
31
ENEC, EMV
1 x TC-L 18
18
0.08
45
0.95
16
31
ENEC, EMV
1 x TC-L 24
24
0.11
45
0.95
22
31
ENEC, EMV
1 x TC-L 40
42
0.19
45
0.95
40
31
ENEC, EMV
1 x TC-TEL 26
26
0.12
45
0.95
24
31
ENEC, EMV
1 x TC-TEL 32
35
0.16
45
0.95
32
31
ENEC, EMV
1 x TC-TEL 42
45
0.21
45
0.95
42
31
ENEC, EMV
2 x T5C 22
48
0.22
45
0.95
22
31
ENEC, EMV
2 x T5 24
52
0.24
45
0.95
24
31
-
2 x T8 15
33
0.15
45
0.95
14
31
-
2 x T8 18
38
0.16
45
0.95
16
31
-
2 x TC-DEL 26
52
0.24
45
0.95
24
31
ENEC, EMV
2 x TC-F 18
36
0.16
45
0.95
16
31
ENEC, EMV
2 x TC-F 24
48
0.22
45
0.95
22
31
ENEC, EMV
2 x TC-L 18
36
0.16
45
0.95
16
31
ENEC, EMV
2 x TC-L 24
48
0.22
45
0.95
22
31
ENEC, EMV
2 x TC-TEL 26
52
0.24
45
0.95
24
31
ENEC, EMV
1 x TC-DEL 26
27
0.13
45
0.95
24
31
ENEC
1 x TC-TEL 26
27
0.13
45
0.95
24
31
ENEC
1 x TC-TEL 32
35
0.16
45
0.95
32
31
ENEC
1 x TC-TEL 42
47
0.21
45
0.95
42
31
ENEC
1 x TC-TEL 57
61
0.27
45
0.95
57
31
ENEC
1 x TC-TEL 70
75
0.33
45
0.95
70
31
ENEC
2 x T5C 22
49
0.22
45
0.95
22
31
ENEC
2 x T5C 40/22
68
0.30
45
0.95
22
31
ENEC
2 x TC-DEL 26
53
0.24
45
0.95
24
31
ENEC
2 x TC-TEL 26
53
0.24
45
0.95
24
31
ENEC
2 x TC-TEL 32
71
0.31
45
0.95
32
31
ENEC
2 x TC-TEL 42
94
0.42
45
0.95
42
31
ENEC
BAG electronics | Product Catalogue 2014
Electronic control gears (non-dimmable) | BCS TC Twingle
Material
number
Control gear for FL
Designation
137
Dimensions | weights | temperatures
Short designation
Length X
Width Y
Hole spacing
XM (length
direction)
Hole spacing
YM (width
direction)
Hole spacing
ZM (height
direction)
Diagram
Weight
Ambient temperature ta
Housing temperature tc,max
°C
mm
mm
mm
mm
mm
mm
kg
°C
BCS21.1-2Q-01
103
67
30
94
57
28
G
0.126
-20 ... 60
75
BCS18.1-2Q-01
103
67
30
94
57
28
G
0.128
-20 ... 60
75
BCS42.1 / 26.2Q-01
103
67
30
94
57
28
G
0.135
-20 ... 60
75
BCS70.1 / 42.2Q-01
103
67
30
94
57
28
G
0.150
-20 ... 50
80
Case drawing
G
Electronic control gears (non-dimmable) | BCS TC Twingle
YM
Y
ZM
Z
X1
XM
X
Wiring diagrams
31
1
2
3
4
5
6
Control gear for FL
138
Height Z
Product Catalogue 2014 | BAG electronics
BAG electronics | Product Catalogue 2014
139
Control gear for FL
Electronic control gears (non-dimmable) | BCS TC Twingle
BCS TC Twingle Independent
Non-dimmable electronic control gear for
CFL, T5 and T8 lamps with TwingleTechnology in independent housing
Electronic control gears (non-dimmable) | BCS TC Twingle Independent
Product information
• Housing with integrated strain relief and terminal cover,
separate for mains power supply and lamp connection
• Plug-in positions for standard terminal blocks designed
for easy feed through
• Multi-Power technology for operation of different lamps
and wattages on the same ECG
Control gear for FL
• Twingle function: operation with 1 or 2 lamps
• Electrode preserving warm start for maximum lamp life,
even at increased switching frequency;
starting time < 1.5 s
• Cut-Off technology: minimised heat current through
electrodes during operation, for optimum light output
and reduced power loss.
• Safety switch-off in case of abnormal lamp operation,
e. g. defective electrode and end of lamp life; tested
acc. to EN 61347-2-3 + Test 2
• Constant lamp output independent of mains voltage
fluctuations
• Optimum ignition safety even at low temperatures:
automatic second start if necessary
• Automatic restart after lamp replacement
• Suitable for direct current operation and emergency
lighting installations; complies with requirements for
emergency lighting according to EN 61347- 2-3/J
• Quick restart of lamps after short power disruptions
• Connecting earth can be disregarded in suitable
luminaires with safety classification II
• Energy efficiency EEI=A2
• Nominal service life: 50.000 h with failure rate of
≤ 10% and operation at tc=tc,max
140
Product Catalogue 2014 | BAG electronics
Industry
    
Office & Commercial
    
Outdoor
    
Shop
    
Technical data
Conformity
EN 61347-1
Mains voltage supply
Rated voltage range
220 ... 240 [V]
EN 61347-2-3
Rated frequency
0 / 50 ... 60 [Hz]
EN 61347-2-3/C
Admissible continuous voltage range
(AC)
198 - 264 [V]
EN 60929
EN 61 00-3-2
Battery operation
Voltage range continuous DC
198 VDC - 278 VDC
Voltage short time DC min.
176 VDC
Overvoltage protection (time)
350 V / 2 h
Max. leakage current
0.5 mA
EN 6100-3-3
EN 61547
EN 55015
Designations
Operating data
Lamp designation
W
W
A
kHz
BCS21.1-2QI-01/220-240
10095743
1 x T5 14
15
0.07
50
0.9
14
31
-
1 x T5 21
22
0.10
50
0.9
21
31
-
BCS18.1-2QI-01/220-240
BCS42.1/26.2QI-01/
220-240
10095744
10095745
System rating
Input current
Operation
frequency
Power factor
Rated power
lamps
Picture
reference
Approval for
lamps
1 x TC-DD 10
15
0.06
50
0.9
10
31
-
1 x TC-DD 16
17
0.07
50
0.9
16
31
-
1 x TC-DEL 10
12
0.06
50
0.9
10
31
ENEC
1 x TC-DEL 13
14
0.06
50
0.9
13
31
ENEC
1 x TC-SE 9
11
0.05
50
0.9
9
31
ENEC
1 x TC-SE 11
13
0.06
50
0.9
11
31
ENEC
1 x TC-TEL 13
14
0.06
50
0.9
13
31
ENEC
2 x T5 14
28
0.13
50
0.9
14
31
-
2 x TC-DD 10
21
0.10
50
0.9
10
31
-
2 x TC-DD 16
29
0.14
50
0.9
16
31
-
2 x TC-DEL 10
21
0.10
50
0.9
10
31
ENEC
2 x TC-DEL 13
27
0.13
50
0.9
13
31
ENEC
2 x TC-SE 9
20
0.09
50
0.9
9
31
ENEC
2 x TC-SE 11
25
0.12
50
0.9
11
31
ENEC
2 x TC-TEL 13
27
0.13
50
0.9
13
31
ENEC
1 x TC-DEL 18
19
0.08
50
0.95
16
31
ENEC
1 x TC-TEL 18
19
0.08
50
0.95
16
31
ENEC
2 x TC-DEL 18
37
0.17
50
0.95
16
31
ENEC
2 x TC-TEL 18
37
0.17
50
0.95
16
31
ENEC
1 x T12 40
37
0.17
45
0.95
40
31
-
1 x T5C 22
24
0.11
45
0.95
22
31
ENEC
1 x T5C 40
42
0.19
45
0.95
40
31
ENEC
1 x T5 24
26
0.12
45
0.95
24
31
-
1 x T5 39
40
0.17
45
0.95
39
31
-
1 x T8 15
17
0.08
45
0.95
14
31
-
1 x T8 18
19
0.09
45
0.95
16
31
-
1 x T8 36
36
0.16
45
0.95
32
31
-
1 x T8 38
37
0.17
45
0.95
32
31
-
1 x TC-DEL 26
26
0.12
45
0.95
24
31
ENEC
1 x TC-F 18
18
0.08
45
0.95
16
31
ENEC
1 x TC-F 24
24
0.11
45
0.95
22
31
ENEC
1 x TC-L 18
18
0.08
45
0.95
16
31
ENEC
1 x TC-L 24
24
0.11
45
0.95
22
31
ENEC
1 x TC-L 40
42
0.19
45
0.95
40
31
ENEC
1 x TC-TEL 26
26
0.12
45
0.95
24
31
ENEC
1 x TC-TEL 32
35
0.16
45
0.95
32
31
ENEC
1 x TC-TEL 42
45
0.21
45
0.95
42
31
ENEC
2 x T5C 22
48
0.22
45
0.95
22
31
ENEC
2 x T5 24
52
0.24
45
0.95
24
31
-
2 x T8 15
33
0.15
45
0.95
14
31
-
2 x T8 18
35
0.16
45
0.95
16
31
-
2 x TC-DEL 26
52
0.24
45
0.95
24
31
ENEC
2 x TC-F 18
36
0.16
45
0.95
16
31
ENEC
2 x TC-F 24
48
0.22
45
0.95
22
31
ENEC
2 x TC-L 18
36
0.16
45
0.95
16
31
ENEC
2 x TC-L 24
48
0.22
45
0.95
22
31
ENEC
2 x TC-TEL 26
52
0.24
45
0.95
24
31
ENEC
Electronic control gears (non-dimmable) | BCS TC Twingle Independent
Material
number
Control gear for FL
Designation
Dimensions | weights | temperatures
Short designation
Length X
Width Y
Height Z
Hole spacing XM
(length direction)
Diagram
Weight
Ambient
temperature
ta
Housing
temperature
tc,max
mm
mm
mm
mm
BCS21.1-2QI-01
180
86
33
191
R
kg
°C
°C
0.190
-20 ... 60
BCS18.1-2QI-01
180
86
33
191
75
R
0.190
-20 ... 60
BCS42.1 / 26.2QI-01
180
86
33
191
75
R
0.195
-20 ... 60
75
BAG electronics | Product Catalogue 2014
141
Control gear for FL
Product Catalogue 2014 | BAG electronics
142
Wiring diagrams
31
1
2
3
4
5
6
Z
Electronic control gears (non-dimmable) | BCS TC Twingle Independent
Y
Y
Z
Case drawing
R
X
XM
BAG electronics | Product Catalogue 2014
143
Control gear for FL
Electronic control gears (non-dimmable) | BCS TC Twingle Independent
BCS TC Linear
Non-dimmable electronic control gear for
CFL, T5 and T8 lamps
Electronic control gears (non-dimmable) | BCS TC Linear
Product information
• Alternative housing to conventional control gear
• Multi-Power technology for operation of different lamps
and wattages on the same ECG
• Twingle function: operation with 1 or 2 lamps
Control gear for FL
• Electrode preserving warm start for maximum lamp life,
even at increased switching frequency;
starting time < 1.5 s
• Cut-Off technology: minimised heat current through
electrodes during operation, for optimum light output
and reduced power loss.
• Safety switch-off in case of abnormal lamp operation,
e. g. defective electrode and end of lamp life; tested
acc. to EN 61347-2-3 + Test 2
• Flimmer free light through high frequency lamp
operation, no stroboscope effect
• Constant lamp output independent of mains voltage
fluctuations
• Optimum ignition safety even at low temperatures:
automatic second start if necessary
• Automatic restart after lamp replacement
• Suitable for direct current operation and emergency
lighting installations; complies with requirements for
emergency lighting according to EN 61347- 2-3/J
• Quick restart of lamps after short power disruptions
• Connecting earth can be disregarded in suitable
luminaires with safety classification II
• Energy efficiency EEI=A2
• Nominal service life: 50.000 h with failure rate of ≤ 10%
and operation at tc=tc,max
144
Product Catalogue 2014 | BAG electronics
Industry
    
Office & Commercial
    
Outdoor
    
Shop
    
Technical data
Conformity
EN 61347-1
Mains voltage supply
Rated voltage range
220 ... 240 [V]
EN 61347-2-3
Rated frequency
0 / 50 ... 60 [Hz]
EN 61347-2-3/C
Admissible continuous voltage range
(AC)
198 - 264 [V]
EN 60929
EN 61 00-3-2
Battery operation
Voltage range continuous DC
198 VDC - 278 VDC
Voltage short time DC min.
176 VDC
Overvoltage protection (time)
350 V / 2 h
Max. leakage current
0.5 mA
EN 6100-3-3
EN 61547
EN 55015
Designations
Operating data
Lamp designation
W
W
A
kHz
BCS21.1-2LS-01/220-240
10095043
1 x T5 14
15
0.07
50
0.9
14
91
-
1 x T5 21
22
0.10
50
0.9
21
91
-
BCS18.1-2LS-01/220-240
10095044
BCS42.1/26.2LS-01/220-240 10095045
System rating
Input current
Operation
frequency
Power factor
Rated power
lamps
Picture
reference
Approval for
lamps
1 x TC-DD 10
15
0.06
50
0.9
10
91
-
1 x TC-DD 16
17
0.07
50
0.9
16
91
-
1 x TC-DEL 10
12
0.05
50
0.9
10
91
ENEC
1 x TC-DEL 13
14
0.07
50
0.9
13
91
ENEC
1 x TC-SE 9
11
0.05
50
0.9
9
91
ENEC
1 x TC-SE 11
13
0.06
50
0.9
11
91
ENEC
1 x TC-TEL 13
14
0.07
50
0.9
13
91
ENEC
2 x T5 14
28
0.13
50
0.9
14
91
-
2 x TC-DD 10
21
0.10
50
0.9
10
91
-
2 x TC-DD 16
29
0.14
50
0.9
16
91
-
2 x TC-DEL 10
21
0.10
50
0.9
10
91
ENEC
2 x TC-DEL 13
27
0.13
50
0.9
13
91
ENEC
2 x TC-SE 9
20
0.09
50
0.9
9
91
ENEC
2 x TC-SE 11
25
0.12
50
0.9
11
91
ENEC
2 x TC-TEL 13
27
0.13
50
0.9
13
91
ENEC
1 x TC-DEL 18
19
0.08
41
0.95
16
91
ENEC
1 x TC-TEL 18
19
0.08
41
0.95
16
91
ENEC
2 x TC-DEL 18
37
0.17
41
0.95
16
91
ENEC
2 x TC-TEL 18
37
0.17
41
0.95
16
91
ENEC
1 x T12 40
37
0.17
45
0.95
40
91
-
1 x T5C 22
24
0.11
45
0.95
22
91
ENEC
1 x T5C 40
42
0.19
45
0.95
40
91
ENEC
1 x T5 24
26
0.12
45
0.95
24
91
-
1 x T5 39
40
0.17
45
0.95
39
91
-
1 x T8 15
17
0.08
45
0.95
14
91
-
1 x T8 18
19
0.09
45
0.95
16
91
-
1 x T8 36
36
0.16
45
0.95
32
91
-
1 x T8 38
37
0.17
45
0.95
32
91
-
1 x TC-DEL 26
26
0.12
45
0.95
24
91
ENEC
1 x TC-F 18
18
0.08
45
0.95
16
91
ENEC
1 x TC-F 24
24
0.11
45
0.95
22
91
ENEC
1 x TC-L 18
18
0.08
45
0.95
16
91
ENEC
1 x TC-L 24
24
0.11
45
0.95
22
91
ENEC
1 x TC-L 40
42
0.19
45
0.95
40
91
ENEC
1 x TC-TEL 26
26
0.12
45
0.95
24
91
ENEC
1 x TC-TEL 32
35
0.16
45
0.95
32
91
ENEC
1 x TC-TEL 42
45
0.21
45
0.95
42
91
ENEC
2 x T5C 22
48
0.22
45
0.95
22
91
ENEC
2 x T5 24
52
0.24
45
0.95
24
91
-
2 x T8 15
33
0.15
45
0.95
14
91
-
2 x T8 18
35
0.16
45
0.95
16
91
-
2 x TC-DEL 26
52
0.24
45
0.95
24
91
ENEC
2 x TC-F 18
36
0.16
45
0.95
16
91
ENEC
2 x TC-F 24
48
0.22
45
0.95
22
91
ENEC
2 x TC-L 18
36
0.16
45
0.95
16
91
ENEC
2 x TC-L 24
48
0.22
45
0.95
22
91
ENEC
2 x TC-TEL 26
52
0.24
45
0.95
24
91
ENEC
BCS28.1LS-01/220-240
10097426
1 x T8 30
30
0.13
45
0.97
30
13
-
1 x TC-DD 28
28
0.12
45
0.97
28
13
ENEC
BCS38.1LS-01/220-240
10097427
1 x T8 36
35
0.15
42
0.98
32
13
ENEC
1 x TC-DD 38
38
0.17
42
0.98
38
13
ENEC
1 x TC-F 36
36
0.16
42
0.98
32
13
ENEC
1 x TC-L 36
36
0.16
42
0.98
32
13
ENEC
BAG electronics | Product Catalogue 2014
Electronic control gears (non-dimmable) | BCS TC Linear
Material
number
Control gear for FL
Designation
145
Dimensions | weights | temperatures
Short designation
Length X
Width Y
mm
mm
mm
mm
BCS21.1-2LS-01
150
42
30
140
Q
BCS18.1-2LS-01
150
42
30
140
BCS42.1 / 26.2LS-01
150
42
30
BCS28.1LS-01
150
42
BCS38.1LS-01
150
42
Case drawing
Electronic control gears (non-dimmable) | BCS TC Linear
Control gear for FL
146
Y
Z
Q
XM
X
Wiring diagrams
13
1
2
3
4
5
6
91
1
2
3
4
5
6
Product Catalogue 2014 | BAG electronics
Height Z
Hole spacing XM
(length direction)
Diagram
Weight
Ambient temperature ta
Housing temperature tc,max
kg
°C
°C
0.121
-20 ... 60
75
Q
0.121
-20 ... 60
75
140
Q
0.119
-20 ... 60
75
30
140
Q
0.119
-20 ... 60
70
30
140
Q
0.119
-20 ... 60
70
BAG electronics | Product Catalogue 2014
147
Control gear for FL
Electronic control gears (non-dimmable) | BCS TC Linear
EBS MINIPOWER
Non-dimmable electronic control gear
for T5, T8 and CFL lamps
Electronic control gears (non-dimmable) | EBS MINIPOWER
Product information
• Electronic control gear for system ratings ≤ 25 W
in small housing
• Electrode preserving warm start for maximum lamp
life,starting time < 1.2 s
• Multi-Power technology for operation of different lamps
and wattages on the same ECG
Control gear for FL
• Safety switch-off in case of abnormal lamp operation,
e. g. defective electrode and end of lamp life; tested acc.
to EN 61347-2-3
• Flimmer free light through high frequency lamp
operation, no stroboscope effect
• Automatic restart after lamp replacement
• Certified as thermally protected control gear, e.g. for
application in luminaires
• Suitable for constant current operation and use in
emergency lighting installations
• Suitable for luminaires in protection class II
• Energy efficiency EEI=A2
• Nominal service life: 40.000 h with a failure rate of
≤ 10% and operation at tc=tc,max
148
Product Catalogue 2014 | BAG electronics
Industry
    
Office & Commercial
    
Outdoor
    
Shop
    
Technical data
Conformity
EN 61347-1
Mains voltage supply
Rated voltage range
220 ... 240 [V]
EN 61347-2-3
Rated frequency
0 / 50 ... 60 [Hz]
EN 61347-2-3/C
Admissible continuous voltage range
(AC)
198 - 264 [V]
EN 60929
EN 61 00-3-2
Battery operation
Voltage range continuous DC
198 VDC - 278 VDC
Voltage short time DC min.
176 VDC
Overvoltage protection (time)
320V / 2 h, 320V /
Max. leakage current
0.5 mA
EN 6100-3-3
EN 61547
EN 55015
Designations
Operating data
Lamp designation
W
W
A
kHz
EBS16.1C-01/220-240
10050989
1 x T5 4
7
0.05
45
0.53
4
9
-
1 x T5 6
6.9
0.06
40
0.5
6
9
VDE, EMV
EBS21.1C-01/220-240
EBS26.1C-01/220-240
EBS16.1M-01/220-240
EBS21.1M-01/220-240
EBS26.1M-01/220-240
10050990
10050992
10050993
10050994
10050996
System rating
Input current
Operation
frequency
Power factor
Rated power
lamps
Picture
reference
Approval for
lamps
1 x T5 8
9
0.07
40
0.5
8
9
VDE, EMV
1 x T5 13
15
0.09
40
0.5
13
9
VDE, EMV
1 x T8 16
15
0.10
40
0.5
16
9
VDE, EMV
1 x TC-DD 10
12
0.08
40
0.5
10
9
VDE, EMV
1 x TC-DD 16
14
0.10
40
0.5
16
9
VDE, EMV
1 x TC-DEL 10
12
0.08
40
0.5
10
9
VDE, EMV
1 x TC-SE 5
7
0.05
45
0.53
5
9
VDE, EMV
1 x TC-SE 7
8
0.06
40
0.5
7
9
VDE, EMV
1 x TC-SE 9
10
0.07
40
0.5
9
9
VDE, EMV
1 x TC-SE 11
12
0.09
40
0.5
11
9
VDE, EMV
1 x TC-DEL 18
17
0.13
40
0.55
16
9
VDE, EMV
1 x TC-TEL 13
14
0.12
40
0.55
13
9
VDE, EMV
1 x TC-TEL 18
17
0.13
40
0.55
16
9
VDE, EMV
1 x TC-DEL 13
14
0.12
40
0.55
13
9
VDE, EMV
1 x T5C 22
21
0.15
40
0.55
22
9
VDE, EMV
1 x T5 24
24
0.18
40
0.55
24
9
VDE, EMV
1 x T8 15
17
0.12
45
0.55
14
9
VDE, EMV
1 x T8 18
16
0.13
40
0.55
16
9
VDE, EMV
1 x TC-DEL 26
25
0.18
40
0.55
24
9
VDE, EMV
1 x TC-F 18
16
0.13
40
0.55
16
9
VDE, EMV
1 x TC-F 24
24
0.17
40
0.55
22
9
VDE, EMV
1 x TC-L 24
24
0.17
40
0.55
22
9
VDE, EMV
1 x TC-TEL 26
25
0.18
40
0.55
24
9
VDE, EMV
1 x T5 6
6.9
0.06
40
0.5
6
9
VDE, EMV
1 x T5 8
9
0.07
40
0.5
8
9
VDE, EMV
1 x T5 13
15
0.09
40
0.5
13
9
VDE, EMV
1 x T8 16
15
0.10
40
0.5
16
9
VDE, EMV
1 x TC-DD 16
14
0.10
40
0.5
16
9
VDE, EMV
1 x TC-DEL 10
12
0.08
40
0.5
10
9
VDE, EMV
1 x TC-SE 7
8
0.06
40
0.5
7
9
VDE, EMV
1 x TC-SE 9
10
0.07
40
0.5
9
9
VDE, EMV
1 x TC-SE 11
12
0.09
40
0.5
11
9
VDE, EMV
1 x T5 14
17
0.12
40
0.55
14
9
VDE, EMV
1 x T5 21
22
0.16
40
0.55
21
9
VDE, EMV
1 x TC-DEL 13
14
0.12
40
0.55
13
9
VDE, EMV
1 x TC-TEL 13
14
0.12
40
0.55
13
9
VDE, EMV
1 x TC-DEL 18
17
0.13
40
0.55
16
9
VDE, EMV
1 x TC-TEL 18
17
0.13
40
0.55
16
9
VDE, EMV
1 x T5C 22
21
0.15
40
0.55
22
9
VDE, EMV
1 x T5 24
24
0.18
40
0.55
24
9
VDE, EMV
1 x T8 18
16
0.13
40
0.55
16
9
VDE, EMV
1 x TC-F 18
16
0.13
40
0.55
16
9
VDE, EMV
VDE, EMV
1 x TC-L 24
24
0.17
40
0.55
22
9
1 x TC-F 24
24
0.17
40
0.55
22
9
VDE, EMV
1 x TC-DEL 26
25
0.18
40
0.55
24
9
VDE, EMV
1 x TC-TEL 26
25
0.18
40
0.55
24
9
VDE, EMV
BAG electronics | Product Catalogue 2014
Electronic control gears (non-dimmable) | EBS MINIPOWER
Materialnumber
Control gear for FL
Designation
149
Dimensions | weights | temperatures
Short designation
Length X
Width Y
Height Z
Weight
Ambient temperature ta
Housing temperature tc,max
mm
mm
mm
mm
EBS16.1C-01
80
42
20
70
P
kg
°C
°C
0.053
-20 ... 55
EBS21.1C-01
80
42
20
70
75
P
0.053
-20 ... 55
EBS26.1C-01
80
42
20
80
70
P
0.053
-20 ... 55
EBS16.1M-01
150
22
80
19
140
F
0.050
-20 ... 55
EBS21.1M-01
150
75
22
19
140
F
0.050
-20 ... 55
EBS26.1M-01
150
75
22
19
-
F
0.050
-20 ... 55
80
Case drawing
Diagram
Wiring diagrams
F
Y
Z
9
XM
X
Z
P
Y
Electronic control gears (non-dimmable) | EBS MINIPOWER
XM
X
Control gear for FL
150
Hole spacing XM
(length direction)
Product Catalogue 2014 | BAG electronics
1
2
3
4
BAG electronics | Product Catalogue 2014
151
Control gear for FL
Electronic control gears (non-dimmable) | EBS MINIPOWER
BCD TC DALI
DALI dimmable electronic control gear for
CFL, T5 and T8 lamps with
Twingle-Technology
Electronic control gears (dimmable) | BCD TC DALI
Product information
• Dim interface: DALI/Push-Dim
• Dim range 3...100% luminous flux
• Multi-Power technology for operation of different lamps
and wattages on the same ECG
• Twingle function: operation with 1 or 2 lamps
• Suitable for dimming amalgam lamps
Control gear for FL
• Electrode preserving warm start for maximum lamp life,
even at increased switching frequency;
starting time < 1.5 s
• Cut-Off technology at 100% luminous flux: minimised
heat current through electrodes during operation, for
optimum light output and reduced power
• Safety switch-off in case of abnormal lamp operation,
e. g. defective electrode and end of lamp life; tested acc.
to EN 61347-2-3 + Test 2
Industry
    
Office & Commercial
    
Outdoor
    
Shop
    
Technical data
Conformity
EN 61347-1
Mains voltage supply
Rated voltage range
220 ... 240 [V]
EN 61347-2-3
Rated frequency
0 / 50 ... 60 [Hz]
EN 61347-2-3/C
Admissible continuous voltage range
(AC)
198 - 264 [V]
EN 60929
EN 62386-102
Battery operation
Voltage range continuous DC
198 VDC - 278 VDC
Voltage short time DC min.
176 VDC
Overvoltage protection (time)
350V / 2 h
Overvoltage protection DALI interface
264 V / permanent
Max. leakage current
0.5 mA
EN 61 00-3-2
EN 6100-3-3
EN 61547
EN 55015
Designations
• Constant lamp output independent of mains voltage
fluctuations
• Automatic restart after lamp replacement
• Suitable for direct current operation and emergency
lighting installations; complies with requirements for
emergency lighting according to EN 61347- 2-3/J
• Quick restart of lamps after short power disruptions
• Energy efficiency EEI=A1
• Nominal service life: 50.000 h with failure rate of ≤ 10%
and operation at tc=tc,max
152
Product Catalogue 2014 | BAG electronics
push
Operating data
Lamp designation
W
W
A
kHz
BCD18.1-2Q-01/
220-240/DALI
10096395
1 x TC-DEL 18
20
0.09
48 ... 100
0.96
16
88
ENEC
1 x TC-TEL 18
20
0.09
48 ... 100
0.96
16
88
ENEC
BCD57.1/32.2Q-01/
220-240/DALI
10096397
System rating
Input current
Operation
frequency
Power factor
Rated power
lamps
Picture
reference
Approval for
lamps
2 x TC-DEL 18
38
0.17
48 ... 100
0.96
16
88
ENEC
2 x TC-TEL 18
38
0.17
48 ... 100
0.96
16
88
ENEC
1 x T5C 22
27.5
0.12
50 ... 125
0.95
22
88
ENEC
1 x T5C 40
44
0.20
50 ... 125
0.95
40
88
ENEC
1 x T5 24
27.5
0.12
50 ... 125
0.95
24
88
-
1 x T5 39
44
0.20
50 ... 125
0.95
39
88
-
1 x T8 15
18
0.08
50 ... 125
0.92
14
88
-
1 x T8 18
20.5
0.09
50 ... 125
0.92
16
88
-
1 x T8 36
37
0.16
50 ... 125
0.95
32
88
-
1 x T8 38
37
0.16
50 ... 125
0.95
32
88
-
1 x TC-DEL 26
27.5
0.13
50 ... 125
0.95
24
88
ENEC
1 x TC-F 18
21
0.10
50 ... 125
0.92
16
88
ENEC
1 x TC-F 24
27
0.12
50 ... 125
0.95
22
88
ENEC
1 x TC-L 18
21
0.10
50 ... 125
0.92
16
88
ENEC
1 x TC-L 24
27
0.12
50 ... 125
0.95
22
88
ENEC
1 x TC-L 40
45
0.20
50 ... 125
0.95
40
88
ENEC
1 x TC-TEL 26
27.5
0.13
50 ... 125
0.95
24
88
ENEC
1 x TC-TEL 32
37
0.17
50 ... 125
0.95
32
88
ENEC
1 x TC-TEL 42
45
0.20
50 ... 125
0.95
42
88
ENEC
1 x TC-TEL 57
63
0.29
50 ... 125
0.95
57
88
ENEC
2 x T5C 22
53
0.24
50 ... 125
0.95
22
88
ENEC
2 x T5C 40/22
70
0.31
50 ... 125
0.95
22
88
ENEC
2 x T5 24
52
0.23
50 ... 125
0.95
24
88
-
2 x T8 15
34
0.15
50 ... 125
0.95
14
88
-
2 x T8 18
38
0.17
50 ... 125
0.95
16
88
-
2 x T8 36
70
0.31
50 ... 125
0.95
32
88
-
2 x TC-DEL 26
55
0.25
50 ... 125
0.95
24
88
ENEC
2 x TC-F 18
39
0.17
50 ... 125
0.95
16
88
ENEC
2 x TC-F 24
53
0.24
50 ... 125
0.95
22
88
ENEC
2 x TC-L 18
39
0.17
50 ... 125
0.95
16
88
ENEC
2 x TC-L 24
53
0.24
50 ... 125
0.95
22
88
ENEC
2 x TC-TEL 26
55
0.25
50 ... 125
0.95
24
88
ENEC
2 x TC-TEL 32
70
0.32
50 ... 125
0.95
32
88
ENEC
Dimensions | weights | temperatures
Short designation
Length X
Width Y
Height Z
Hole spacing
XM (length
direction)
Hole spacing
YM (width
direction)
Hole spacing
ZM (height
direction)
mm
mm
mm
mm
mm
mm
BCD18.1-2Q-01
103
67
30
94
57
28
BCD57.1 / 32.2Q-01
103
67
30
11
90
30
Case drawing
Diagram
Weight
Ambient
temperature
ta
Housing
temperature
tc,max
kg
°C
°C
G
0.139
5 ... 50
75
G
0.162
5 ... 50
75
Electronic control gears (dimmable) | BCD TC DALI
Material
number
Control gear for FL
Designation
Wiring diagrams
88
Y
Ym
Y
G
Xm
X
Push-DIM
L
N
Push-DIM
DA L
DA N
DA
DA
1
2
3
4
5
6
1
2
3
4
5
6
EVG_AB_10096397_Twingle_DALI(110223).eps
EVG_AB_10096397_Twingle_DALI(110223).eps
BAG electronics | Product Catalogue 2014
153
BCD TC 1-10V
Dimmable electronic control gear for CFL,
T5 and T8 lamps with Twingle-Technology
Electronic control gears (dimmable) | BCD TC 1-10V
Product information
• Dim interface: 1–10 V
• Dim range 3...100% luminous flux
• Multi-Power technology for operation of different lamps
and wattages on the same ECG
• Twingle function: operation with 1 or 2 lamps
• Suitable for dimming amalgam lamps
Control gear for FL
• Electrode preserving warm start for maximum lamp life,
even at increased switching frequency;
starting time < 1.5 s
• Cut-Off technology at 100% luminous flux: minimised
heat current through electrodes during operation, for
optimum light output and reduced power
• Safety switch-off in case of abnormal lamp operation,
e. g. defective electrode and end of lamp life; tested
acc. to EN 61347-2-3 + Test 2
• Constant lamp output independent of mains voltage
fluctuations
• Automatic restart after lamp replacement
• Suitable for direct current operation and emergency
lighting installations; complies with requirements for
emergency lighting according to EN 61347- 2-3/J
• Quick restart of lamps after short power disruptions
• Energy efficiency EEI=A1
• Nominal service life: 50.000 h with failure rate of
≤ 10% and operation at tc=tc,max
154
Product Catalogue 2014 | BAG electronics
Industry
    
Office & Commercial
    
Outdoor
    
Shop
    
Technical data
Conformity
EN 61347-1
Mains voltage supply
Rated voltage range
220 ... 240 [V]
EN 61347-2-3
Rated frequency
0 / 50 ... 60 [Hz]
EN 61347-2-3/C
Admissible continuous voltage range
(AC)
198 - 264 [V]
EN 60929
EN 61 00-3-2
Battery operation
Voltage range continuous DC
198 VDC - 278 VDC
Voltage short time DC min.
176 VDC
Overvoltage protection (time)
350 V / 2 h
Max. leakage current
0.5 mA
Max. control current (1-10V)
0.2 mA
EN 6100-3-3
EN 61547
EN 55015
Designations
Operating data
BCD18.1-2Q-01/220-240/1- 10096385
10V
BCD57.1/32.2Q-01/220240/1-10V
10096387
BCD13.1-2Q-01/220-240/1- 10096393
10V
Lamp designation
System rating
Input current
Operation
frequency
Power factor
Rated power
lamps
Picture
reference
Approval for
lamps
W
A
kHz
1 x TC-DEL 18
20
0.09
50 ... 125
0.96
16
78
ENEC
1 x TC-TEL 18
20
0.09
50 ... 125
0.96
16
78
ENEC
2 x TC-DEL 18
38
0.17
50 ... 125
0.96
16
78
ENEC
2 x TC-TEL 18
38
0.17
50 ... 125
0.96
16
78
ENEC
1 x T5C 22
27
0.12
50 ... 125
0.95
22
78
ENEC
1 x T5C 40
44
0.20
50 ... 125
0.95
40
78
ENEC
1 x T5 24
27
0.12
50 ... 125
0.95
24
78
-
1 x T5 39
43
0.19
50 ... 125
0.95
39
78
-
1 x T8 15
18
0.08
50 ... 125
0.95
14
78
-
1 x T8 18
20
0.09
50 ... 125
0.95
16
78
-
1 x T8 36
36
0.16
50 ... 125
0.95
32
78
-
1 x T8 38
36
0.16
50 ... 125
0.95
32
78
-
1 x TC-DEL 26
27
0.13
50 ... 125
0.95
24
78
ENEC
1 x TC-F 18
20
0.09
50 ... 125
0.92
16
78
ENEC
1 x TC-F 24
26
0.12
50 ... 125
0.95
22
78
ENEC
1 x TC-L 18
20
0.09
50 ... 125
0.92
16
78
ENEC
1 x TC-L 24
26
0.12
50 ... 125
0.95
22
78
ENEC
1 x TC-L 40
44
0.20
50 ... 125
0.95
40
78
ENEC
1 x TC-TEL 26
27
0.13
50 ... 125
0.95
24
78
ENEC
1 x TC-TEL 32
36
0.16
50 ... 125
0.96
32
78
ENEC
1 x TC-TEL 42
45
0.20
50 ... 125
0.95
42
78
ENEC
1 x TC-TEL 57
63
0.28
50 ... 125
0.95
57
78
ENEC
2 x T5C 22
52
0.23
50 ... 125
0.95
22
78
ENEC
2 x T5C 40/22
69
0.30
50 ... 125
0.95
22
78
ENEC
2 x T5 24
52
0.23
50 ... 125
0.95
24
78
-
2 x T8 15
34
0.15
50 ... 125
0.95
14
78
-
2 x T8 18
38
0.17
50 ... 125
0.95
16
78
-
2 x T8 36
70
0.31
50 ... 125
0.95
32
78
-
2 x TC-DEL 26
55
0.25
50 ... 125
0.95
24
78
ENEC
2 x TC-F 18
38
0.17
50 ... 125
0.95
16
78
ENEC
2 x TC-F 24
52
0.23
50 ... 125
0.95
22
78
ENEC
2 x TC-L 18
38
0.17
50 ... 125
0.95
16
78
ENEC
2 x TC-L 24
52
0.23
50 ... 125
0.95
22
78
ENEC
2 x TC-TEL 26
55
0.25
50 ... 125
0.95
24
78
ENEC
2 x TC-TEL 32
70
0.31
50 ... 125
0.96
32
78
ENEC
1 x TC-DEL 13
16
0.07
50 ... 125
0.96
13
78
ENEC
Electronic control gears (dimmable) | BCD TC 1-10V
Material
number
Control gear for FL
Designation
1 x TC-TEL 13
16
0.07
50 ... 125
0.96
13
78
ENEC
2 x TC-DEL 13
32
0.13
50 ... 125
0.98
13
78
ENEC
2 x TC-TEL 13
32
0.13
50 ... 125
0.98
13
78
ENEC
Diagram
Weight
Ambient
temperature
ta
Housing
temperature
tc,max
Dimensions | weights | temperatures
Short designation
Length X
Width Y
Height Z
Hole spacing
XM (length
direction)
Hole spacing
YM (width
direction)
Hole spacing
ZM (height
direction)
mm
mm
mm
mm
mm
mm
kg
°C
°C
BCD18.1-2Q-01
103
67
30
94
57
28
G
0.132
5 ... 50
75
BCD57.1 / 32.2Q-01
103
67
30
94
57
28
G
0.157
5 ... 50
75
BCD13.1-2Q-01
103
67
30
94
57
28
G
0.132
5 ... 50
75
Wiring diagrams
G
78
Ym
Y
Case drawing
Y
1−10 V
Xm
X
1
2
3
4
5
6
BAG electronics | Product Catalogue 2014
155
BCD CFL and T5-C 1-10V
Dimmable electronic control gear for CFL
and T5-C lamps
Electronic control gears (dimmable) | BCD CFL and T5-C 1-10V
Product information
• Dim interface: 1–10 V
• Dim range 3...100% luminous flux
• Multi-Power technology for operation of different lamps
and wattages on the same ECG
• Suitable for dimming amalgam lamps
Control gear for FL
• Electrode preserving warm start for maximum lamp life,
even at increased switching frequency;
starting time < 1.5 s
• Cut-Off technology at 100% luminous flux: minimised
heat current through electrodes during operation, for
optimum light output and reduced power
• Safety switch-off in case of abnormal lamp operation,
e. g. defective electrode and end of lamp life;
tested acc. to EN 61347-2-3 + Test 2
• Constant lamp output independent of mains voltage
fluctuations
• Automatic restart after lamp replacement
• Suitable for direct current operation and emergency
lighting installations; complies with requirements for
emergency lighting according to EN 61347- 2-3/J
• Quick restart of lamps after short power disruptions
• Energy efficiency EEI=A1
• Nominal service life: 50.000 h with failure rate of
≤ 10% and operation at tc=tc,max
156
Product Catalogue 2014 | BAG electronics
Industry
    
Office & Commercial
    
Outdoor
    
Shop
    
Technical data
Conformity
EN 61347-1
Mains voltage supply
Rated voltage range
220 ... 240 [V]
EN 61347-2-3
Rated frequency
0 / 50 ... 60 [Hz]
EN 61347-2-3/C
Admissible continuous voltage range
(AC)
198 - 264 [V]
EN 60929
EN 61 00-3-2
Battery operation
Voltage range continuous DC
198 VDC - 278 VDC
Voltage short time DC min.
176 VDC
Overvoltage protection (time)
350V / 2 h
Max. leakage current
0.5 mA
Max. control current (1-10V)
0.2 mA
EN 6100-3-3
EN 61547
EN 55015
Designations
Designation
Material
number
Lamp designation
System rating
Input current
Operation
frequency
Power factor
Rated power
lamps
Picture
reference
Approval for
lamps
W
W
A
kHz
BCD36.2Q-01/220-240/110V
10096326
2 x TC-L 36
70
0.31
40 ... 120
0.95
32
78
ENEC
BCD55.1Q-01/220-240/110V
10096388
1 x T5C 55
59
0.26
40 ... 120
0.98
55
63
ENEC
BCD60.1Q-01/220-240/110V
10096389
1 x T5C 60
64
0.28
40 ... 120
0.98
60
63
ENEC
BCD42.2Q-01/220-240/110V
10097580
2 x TC-DEL 26
55
0.24
40 ... 120
0.98
24
73
ENEC
2 x TC-TEL 26
55
0.24
40 ... 120
0.98
24
73
ENEC
2 x TC-TEL 32
70
0.31
40 ... 120
0.98
32
73
ENEC
2 x TC-TEL 42
90
0.40
40 ... 120
0.95
42
73
ENEC
Dimensions | weights | temperatures
Short designation
Length X
Width Y
Height Z
Hole spacing
XM (length
direction)
mm
mm
mm
BCD36.2Q-01
103
67
30
BCD55.1Q-01
103
67
30
94
Hole spacing
YM (width
direction)
Hole spacing
ZM (height
direction)
Diagram
mm
mm
mm
94
57
28
G
57
28
G
Weight
Ambient
temperature
ta
Housing
temperature
tc,max
kg
°C
°C
0.156
5 ... 50
80
0.142
5 ... 50
80
BCD60.1Q-01
103
67
30
94
57
28
G
0.142
5 ... 50
80
BCD42.2Q-01
123
102
33
94
90
30
G
0.237
5 ... 50
75
Case drawing
Wiring diagrams
63
Zm
Z
G
Y
1−10 V
Xm
X
Control gear for FL
1
2
3
4
Electronic control gears (dimmable) | BCD CFL and T5-C 1-10V
Operating data
73
L
N
1−10 V
1
2
3
4
5
6
7
8
78
1−10 V
1
2
3
4
5
6
BAG electronics | Product Catalogue 2014
157
Accessories
Diffusor for linear LED modules
Product information
• Plastic profile for ASTARES linear LED modules 2nd Generation
• 3 different standard lengths
• Toolless clip fastening on holder element
• Suitable as protection against touching in case of non-SELV operation
• Diffuse light distribution with high optical system efficiency of 94%
• Material: PMMA; white
1,2
5
Model
22,10
R1
8
3
Drawing
46,20
Material
Number
Length
[mm]
Diffusor ASTARES linear L593
10111464
593
Diffusor ASTARES linear L1131
10111463
1131
Diffusor ASTARES linear L1431
10111461
1431
Holder element
Product information
• Holder element for ASTARES linear LED modules 2nd Generation
• Optimized thermal-mechanical fixation of LED module
• Toolless clip fastening of optical covers (optional)
• M4 screw with TORX drive included
• Material: PBT, white
Zubehör
158
Product Catalogue 2014 | BAG electronics
Model
Material
Number
Dimensions
[mm]
Holder element ASTARES Linear
10111465
38 x 13,6 x 9
Accessories
Release spike
Product information
• Operating tool for wire release
• Suitable for terminals with release hole
• Ergonomic soft grip handle
• Flattened spike with 1,0 mm diameter and depth gauge
Model
Release spike
Material
Number
Dimensions
[mm]
10075741
138 x 20 x 20
ZITARES Programming Tool
Product information
• Programming tool for parameter setting and monitoring of
ZITARES DALI ECGs
• To be used together with ZITARES 360 PC software
• USB port (2.0; type B) for standard PC connection; Push-in termianls for
flexible wiring of ECGs
• Optional auxiliary DC power input for increase of DALI bus supply current
• Status indication (data transmit, data receive, power) by coloured LEDs
• Compact housing with terminal cover and strain reliefs
Material
Number
Dimensions
[mm]
ZITARES Programming Tool
10112596
180 x 86 x 33
Zubehör
Model
ZITARES 360 Programming Software
Product information
• ZITARES 360 graphical user interface for programming and
analysis of ZITARES DALI ECGs
• System requirement: PC with Microsoft Windows incl. USB port
• Separated user levels for development, production and
analysis of operation
• Intuitively use of software supported by integrated FAQ
• Direct ECG plug & program solution for fast programming
• Full traceability concept
T5
Please contact us for further information and software download.
BAG electronics | Product Catalogue 2014
159
Download