Technologies for the light of tomorrow. Components for LED applications • Electroniccontrolgear • LEDmodules • LEDlightengine Components for fluorescent lamps • Electroniccontrolgear www.BAGelectronics.com BAG electronics | Product Catalogue 2014 1 2 Product Catalogue 2014 | BAG electronics 22 Shop 30 Outdoor 38 Industry Industry Shop 14 Outdoor Office & Commercial Office & Commercial Applications Components for fluorescent lamps Electroniccontrolgear Accessories 100 158 BAG electronics | Product Catalogue 2014 Components for fluorescent lamps Electroniccontrolgear LEDmodules LEDlightengine 40 Accessories Components for LED applications Components for LED applications Products 3 BAG: Your expert partner for electronic ballasts for LED components, fluorescent lamps and high pressure discharge lamps. Energy efficiency combined with quality and operational safety. If it’s a matter of individual concepts for special requirements, then customers aroand the world place their trust in control gear and solutions from BAG, developed and constructed to achieve high efficiency, high safety and high functionality. 4 Product Catalogue 2014 | BAG electronics Intelligent and efficient solutions for the light of tomorrow. Your partner for lighting electronics. Lightisourworld:BAGelectronicsisesteemedacrosstheworldasa premierpartnertothelightingindustry.Wecreateinnovativesolutionsandnewconceptsforgreaterefficiencyandlowerenergyconsumption.Ourcorporategroupdevelops,manufacturesandmarkets highqualityelectroniccomponentsforlightingapplications–with maximumqualityandreliabilityincluded. Discovertomorrow‘slightingsolutionstoday:energyefficiency combinedwithqualityandoperationalsafety.Individualconceptsfor specialneeds:customersaroandtheglobeplacetheirtrustinour solutionswhenitcomestosuchobjectives.Developedandconstructedtoachievehighefficiency,highsafetyandhighfunctionality. ThismakesBAGoneofthetopaddressesworldwideforlighting electronics. Our platform strategy – for your benefit Wepursueaconsistentplatformstrategyinallour productgroups. Youradvantage:anoptimumprocessefficiencywithuniformhousingsizesandidenticalwiringforeachproduct group.Smartfeaturesandaslimdesignprovideflexibility foryourlightingdesign. Efficient solutions for the light of tomorrow. Components for LED applications BAGoffersawidespectrumofelectronic controlgearfortheoperationofLED moduleswiththeZITARESproductfamily, andperformancefeaturesareprimarily aimedattheuseoftheECGinprofessional generallightingapplicationswithwhitelight. Thedifferingversionsofferoptimalsolutions forawidearrayofapplicationsforexamplein theoffice,school,industryandshopsectors. LED modules ASTARESrepresentsanassortmentofLED modulesdesignedforawidediversityof lightingtasks.Hereapplicationswithmainly linearaswellasplanelightsourceswere takenintoaccount. LED light engine WithNEXARES,BAGpresentsalightengine whereLEDmoduleandelectroniccontrol unitarecombinedonaPCB,anall-in-one solution.Thedesignhasalsofocusedon minimumconstructionheight.Withaheight ofonly8mmandwithoutthenecessityofan additionalcontrolgearhavingtobeinstalled intheluminaire,NEXARESenablesmaximum flexibilityforluminairedesign. Page52 Page94 Page98 BAG electronics | Product Catalogue 2014 5 Future-fit from tradition. Our history is the basis for perfect solutions Future-fitfromtradition:BAGhasalwaysbeenabletoidentifyfuture technologicalsectorsatanearlystageanddevelopexactsolutions forthese.Ourcompanyrootsreachbacktotheyear1909.Andmore than40yearsagothefirstignitersandballastsweremanufacturedin TurgiinSwitzerland.Thissignifiedthestartofoursuccessstoryasa partnerforthelightingindustry. It‘stheexpertiseandexperienceofourapproximately3,000employeesaroandtheworldthatmakesthedifference.Inaddition toheadquartersinArnsberg,Germany,wealsomaintainsalesand developmentlocationsinEuropeandAsiaaswellasstate-of-the-art productionsitesinChina,IndiaandonthePhilippines.andourproductsaremarketedaroandtheworldinover50countries. 1909 1967 1968 1972 1981 1998/99 The roots of the company BAG Turgi initiates production of igniters and ballasts BAG Turgi launches the first hot restrike igniters to the market Superimposedpulse igniters replace thyristorcontrolled igniters The first electronic control gear are presented A production site is founded on the Philippines Withinventionofthe highpressuresodium vapourlampbyGE,BAG startsproductionofa supplyunitconsistingofa thyristor-controlledigniter andinductiveballast. ThecompanyofOsram releasesthefirstthyristorcontrolledsuperimposedpulseignitersfromBAG foroperating400Whigh pressuresodiumvapour lamps.Furtherigniter approvalsfollow. Thefirstsuperimposedpulseigniterswith bi-metalstarterunder thenameofSM6replace thyristor-controlled ignitersasswitching elements. Weshowelectroniccontrolgearforthefirsttime attheHanovertradefair. Thefirstforeignmanufacturinglocationis foundednearManilaon thePhilippines. TheSwissBroncegussAG (BAG)isfoundedinTurgi/ Switzerland. 6 Product Catalogue 2014 | BAG electronics Expansion in China Aproductionsiteisfounded inZhuhai. Our Locations 3 1 2 4 6 7 8 9 5 1 Arnsberg, Germany 4 Marketing&sales,research& development,production, administration 2 5 Sales,research&development 3 Espelkamp, Germany Sales 6 Pune, India Beijing, China Hong Kong, China Marketing,sales 10 Zhuhai, China Production,sales,research&development 9 Sales 7 Production,sales,research&development London, United Kingdom 8 Sales Mailand, Italy 10 Manila, Philippines Production,sales Guangzhou, China Sales,research&development 2000 2002 2005 2009/10 2012 2013/14 The advent of Multi-Lamp Technology Company takeover and relocation of BAG Turgi to Arnsberg Market launch of Zirius hot restrike igniters BAG electronics takes over HÜCO Lightronic from Espelkamp BAG foands the LEDcycle ZITARES intelligent revolutionises LED control Aneweracomesabout withproductionofthe world‘sfirstelectronic ballastsforfluorescent lampswithmulti-lamp technology. BAGelectronicsGmbH isfoundedin2002with itslocationatArnsberg, Germany.Thefurther expansionalsocoversall activitiesintheareasof production,development, salesmanagement, marketing,procurement andlogistics. Inthehotre-ignition sectorthenewZIRIUS generationofferscompletelyelectronicignition deviceswithintelligent ignitionmanagement systemstoachieveseveral useradvantages. Thepremiumquality productsbecomeapartof theBAGexpandedproduct portfolio,andHÜCO employeesstrengthenthe organisation.Rightontime forLight+Building2010: thedual-brandstrategy isreplacedwiththenew corporatedesign,and HÜCOLightronicisalso calledBAG Byfoandinganown businesssector,allactivitiesconcerningthefuture technologyofLEDare bandledtotheadvantage ofcustomers. Everythingfromasingle source:BAGprovidesa completesolutionwith thereliableandhigh- performanceLEDECG fromtheZITARESfamily andtheZITARES360 software.ZITARESintelligentmakesLEDcontrol technologymoreflexible thaneverbefore. BAG electronics | Product Catalogue 2014 7 Quality without compromise The satisfaction of our customers is always our focus. Qualityknowsnocompromises:thesatisfactionofourcustomersis alwaysofprimaryimportanceforus.Matureandoptimisedquality managementbasedonISOcertificationguaranteesthequalityand reliabilitytobeexpectedofBAGproducts.Forus,thequalitycontrol ofeachindividualproductisasnaturalasthecarefulselectionof suppliersandcontinuousmonitoringofallquality-relevantprocesses. Eachproductisfundamentallyinspectedpriortodispatch.Testing meansaredevelopedinGermanyaccordingtothecurrentstateof technologyandthusensureahomogeneouslevelofqualityacrossall locations,onaglobalscale. Efficiency and precision Expect more from us. Theobjectiveacknowledgementofthecomprehensivequalitymanagementsystemisreflectedinmanyinternationalqualityattributes thatdistinguishourproducts.AccreditationofourdevelopmentlaboratoryincompliancewiththeTestDataAcceptanceProgram(TDAP)of theVDEaffordsadditionalsecurity. Qualityandprecisionarethepreconditionsfordependablelighting solutions–simplyexpectmoreofus.Moreservice,individualsolutionsandindividualtechnicalcustomersupport. BAGISO9001:2008-Certificate 8 Product Catalogue 2014 | BAG electronics BAGISO9001:2008IQNet BAG 5 years warranty – Full security completely without registration. WithBAGproductsyoualwaystakethedecisionforinnovativetechnology,constantlyhighmanufacturingstandardsandabove-average operationaldurations.Ourbrandrepresentsqualitythatyoucan permanentlyrelyon,combinedwithmaximumstandardsofquality andefficientprocesses. Thislevelofreliabilitybenefitsyouintheformofhigheconomic efficiencyandahighlevelofoperationalsafety.Inordertobestmeet yourexpectationswithregardtoqualityandperfection,weoffer youabove-averagewarrantytimes,simpleandsafe,andcompletely withoutregistrationbeforehand. BAG electronics | Product Catalogue 2014 9 LEDcycle Your requirements in focus Your requirements in focus Reliable,safeandenergy-efficientsystems aredemandedrangingfromluminairedesign tooptimallymatchedelectronics.Thisis whyBAGhasbandledallcomponentsand developedtheLEDcycle:focusedexpertise andexperiencepreciselymatchedtoyour requirements.TheLEDcycleoffersyoumuch morethanjusttherightECGorLEDmodule– youreceivenotonlyproductsbutsolutions, andmatchedentirelytoyourneeds. 10 Product Catalogue 2014 | BAG electronics Technical Roadmap Competence 1 Rapidavailabilitycoordinatedpreciselyto specificdemands–theBAGplatformsmeet theneedsofluminairemanufacturersacross awidespectrum.ThecombinationofelectroniccontrolgearandLEDmoduleshave beendesignedforspecificapplicationsand permanentlysimplifyproductionplanning andlogisticsforluminaireproducers.Inthe dynamicLEDsectorit‘sallaboutshortinnovationcycles,andtheplatformsarecreated preciselywiththisinmindastheyenable rapidityofproductdevelopmentandalways offeryouthelateststateoflightingelectronics.Afurtherbenefit:thankstotheBAG platformstrategy,luminairemanufacturers candesignmodularluminairesystems,can simplifyprocurementandmakeproduction significantlymoreflexible.TheBAGisactively workingwiththeindustrialconsortium Zhaga,thisdealswiththestandardization ofLEDcomponents. Product Portfolio Competence 2 ECG,modulesandlightengines:all componentsoftheBAGLEDsystemare optimallymatchedtoeachotherandoffer maximumflexibilityforcustomer-specific demandsandawidespectrumofapplications,rangingfromshopsandofficesto administrationbuildingsandindustrialhalls. Luminaireproducersalwaysfindtheright solutionwiththecomplete,modularBAG portfolio.Professionallightingimplemented preciselyaccordingtoaims. Whether for offices, shops, industrial halls or public buildings, LED technology has reductionised the most varied of application in lighting technology as quickly and sustainably as never before. Competencies Competence 3 OfcourseBAGdedicateditselfatanearly stagetoLEDtechnology,andtheresultis tried-and-proven,future-fitsolutionsfor lightingelectronics.ThisappliestoLEDECGs aswellasLEDmodulesandlightengines thatinparticularmeetthedemandsof thermalmanagement,opticsandmechanics. Nolessimportantissuitablesoftware.This enablesspecialapplicationstobeoptimised andproductdevelopmenttobeaccelerated. Systemsforthesimulationofelectric,optic andthermalinfluencesareapermanentpart oftheBAGdevelopmentprocess,asis practicaltesting. Youradvantage:highreliabilityandquality thatyoucandependon,evenanderextreme conditionsofuse. Partnerships Competence 4 Hand-in-handtoachievethetarget: strategicpartnershipsformthebasisforrapid andsuccessfuldevelopmentoffuturesafe andpremiumqualityproducts.BAGis organisedonaglobalscaleandatthe sametimeclosetocustomers,tightlyrooted andorientedtothefuture.Thisappliesnot justtotechnologiesbutalsotosuppliers, researchanddevelopment,production locations,andalsotothetightand consultation-orientedpartnershipwith customers. Process Competence 5 Thankstodecadesofexperienceindevelopmentandmanufacturing,BAGisapartner torenownedluminairemanufacturersasa supplieroflightingelectronics,andisestablishedacrosstheworld.Demandsintheera ofLEDcontinuallyincreaseandchange,and therequirementsofresearchanddevelopmentarestringent.ThisiswhyBAGfocuses allexpertiseandresourcesintoanewunit thatsupportsyouevenmorequickly,more individuallyandwithmoreservicequality acrossthecompleteprocesschain.Thenew LEDunitconcentratesexclusivelyonthis futuremarket,isgloballyorganisedand unitesourdecadesofexistingexpertise andexperience. BAG electronics | Product Catalogue 2014 11 Precisely the right solution for any luminaire From LED continuous lines to downlights. Linear Plane ECG ECG ZITARES CC 2-Channel SELV dimmable CCD270-70LS-01/220-240/DALI ZITARES CC 2-Channel SELV dimmable 66 ZITARES CC 1-Channel SELV dimmable CCD1100-50FR-20/200-240/DALI 62 62 NCD135-70FX-20/220-240/DALI 88 Modules ASTARES linear 1100lm/280 mm ASTARES linear 1100lm/280 mm 94 ASTARES linear 2200lm/560 mm LMC-AS-200-840-LP-20/L56W4 CCD1100-50FR-20/200-240/DALI ZITARES NC 1-Channel non-SELV dimmable 68 Modules LMC-AS-110-840-LP-20/L28W4 66 ZITARES CC 1-Channel SELV dimmable ZITARES NC 1-Channel non-SELV dimmable NCD135-70FX-20/220-240/DALI CCD270-70LS-01/220-240/DALI LMC-AS-110-830-LP-20/L28W4 94 ASTARES linear 2200lm/560 mm 94 LMC-AS-200-840-LP-20/L56W4 94 Light-Engine NEXARES All-in-One 1300lm LMM-NE-110-840-RP-02 98 NEXARES All-in-One 2000lm LMM-NE-200-840-RP-02 12 Product Catalogue 2014 | BAG electronics 98 Our product range BAGoffersyouamodern,continuouslyexpandedportfolioofproducts andenergy-efficient.Ourassortmentfocusesoncontrolgear andsolutionsforlightingelectronicsthataresafe,qualitative,reliable forfluorescentlampsandfuture-fitsolutionswithLED. Downlight Spot ECG ECG ZITARES UC 1-Channel SELV non-dimmable UCS170-20LI-11/100-240 ZITARES UC 1-Channel SELV non-dimmable 54 ZITARES CC 1-Channel SELV dimmable CCD170-35QS-01/220-240/DALI 54 ZITARES CC 1-Channel SELV dimmable 58 ZITARES CC 2-Channel SELV dimmable CCD270-70QS-01/220-240/DALI UCS170-35LI-11/100-240 CCD170-35QS-01/220-240/DALI 58 ZITARES CC 2-Channel SELV dimmable 70 CCD270-70QS-01/220-240/DALI 70 Light-Engine NEXARES All-in-One 1300lm LMM-NE-110-840-RP-02 98 NEXARES All-in-One 2000lm LMM-NE-200-840-RP-02 98 BAG electronics | Product Catalogue 2014 13 Office & Commercial Modern worlds of work Light for offices and communication Transparency,communicationandflexibility. Modernworkingenvironmentshavecauseda newwayofthinkingintermsofarchitectureand buildingtechnology,andthisincludescustomdesignedlightingsolutions.Goodlightplanning createspositiveroomatmospheresthatimprove well-beingandthusalsotheperformance capabilityofemployees.LEDtechnologyhas alreadydecisivelyconqueredtheworldofoffices, butthefactorofsustainabilityisjustasimportant –energyefficiencyandlowlevelsofmaintenance gohand-in-hand.Efficientelectronicsformodern officelightingcomesfromBAG. 14 Product Catalogue 2014 | BAG electronics Office & Commercial BAG electronics | Product Catalogue 2014 15 Office & Commercial 16 Product Catalogue 2014 | BAG electronics Office & Commercial LED modules for offices and public areas →Lowmaintenanceandoperationcostsduetolonglifetimeand veryhighefficiencyofmodules →Highqualitylightforextendentvisualcomfort →Idealforlinearandplanarluminaires Components for LED applications ASTARES linear ›Page94 BAG electronics | Product Catalogue 2014 17 Office & Commercial 18 Product Catalogue 2014 | BAG electronics Office & Commercial ZITARES intelligent is the first LED ECG that individually adapts to your luminaires and projects – precisely as you need. Withconstantluminousfluxovertheoperatingdurationtoindependentandindividualcontrolofthetwooutputchannels,theECGcanbe flexiblyusedinawidevarietyofluminaires,rangingfromlineartofreestandingluminaires,settingyourprojectintherightlight.Thecoreof theintelligentECGisamicrocontrollerthatoptimisesyourluminairesin combinationwithoptionalsensorsforawidevarietyofapplications.All parametersareconfiguredwiththeZITARES360software.Thisintegrates seamlesslyintoyourdevelopmentandproductionprocess. Inadditiontomanyfunctionselectionoptions,ZITARESalsofeatures intelligentsafetyforthefuture.Thankstosmartinterfacecommunication, ECGdatacanbeprogrammedandreadoutwithhighspeed,andyour luminairescanalsobeequippedwithupdates. Components for LED applications ZITARES intelligent ›Page74 BAG electronics | Product Catalogue 2014 19 Office & Commercial 20 Product Catalogue 2014 | BAG electronics Office & Commercial Compact and with combined DALI / Push-DIM interface Control gear for FL BCD TC DALI TWINGLE DIM – →FullflexibilityandreductionofECGvarietyduetoMulti-power technologycombinedwithtwinglefuncionality →Optimalmaintenanceefficiencyandreliabilitybasedona max.lifetimeof100.000operatinghourstogetherwith BAG5yearswarranty →ComfortableandeasycontrolviapushbuttonorDALI →BestavailableenergyefficiencyclassEEI=A2BAT ›Page152 BAG electronics | Product Catalogue 2014 21 Series productivity Light for industry and technology Industry 22 Industrialapplicationsplaceparticulardemands onlighting:maximumreliability,functionality, flexiblemodifications,expandabilityandalso highenergyefficiency.Therightlighthasa majorinfluenceonproductivityandfriction-free processes,andqualitystandardsarehigh. Youcanbesureofmakingtherightchoicein thisapplicationsectorwithBAGsolutionsfor lightingelectronics. Product Catalogue 2014 | BAG electronics Industry BAG electronics | Product Catalogue 2014 23 Industry 24 Product Catalogue 2014 | BAG electronics Industry Efficient LED modules with linear design. →Lowmaintenanceandoperationcostsduetolonglifetime andhighefficiencyofmodules →Optimizedthermalmanagementforuseinroughenvironments →Cascadabledesignallowslumenpackagesofmorethan20,000lm suppliedbyacentralECG ->Idealforcontinuouslineandwater-proofluminaires Components for LED applications ASTARES linear ›Page94 BAG electronics | Product Catalogue 2014 25 Industry 26 Product Catalogue 2014 | BAG electronics Industry Optimum energy efficiency →FullflexibilityandreductionofECGvarietyduetoT5Multi-Lamp technologycombinedwithtwinglefuncionality →Optimalmaintenanceefficiencyandreliabilitybasedonamax. lifetimeof100.000operatinghours →Suitableforuseintemperature-criticalindustryapplications Control gear for FL MLS EVO II für T5 Lampen ›Page112 BAG electronics | Product Catalogue 2014 27 Industry 28 Product Catalogue 2014 | BAG electronics Industry Electronic control gear units (LED) Components for LED applications ZITARES NCS 2nd Generation →Adjustableoutputcurrentforflexibleandfuture-proof operationofLEDmodules →LonglifetimeandexcellentreliabilitywithBAG5yearwarranty →Bestavailableenergyefficiencyupto94%andoptimizedcircuit designforlowapplicationcosts ›Page86 BAG electronics | Product Catalogue 2014 29 Shopping as an experience Light for shops Shop 30 Transformingshoppingintoanexperience: Retaillandscapesplannedindetailcommunicate withcustomersonanemotionallevelandalso haveasales-promotingeffect.LEDlighting solutionsareindispensableatthePOSinorder tooptimallypresentproductsbothindividually andwithhighenergyefficiency.BAGisyour supplierforhigh-performanceanddurable electronicsforretaillighting. Product Catalogue 2014 | BAG electronics Shop BAG electronics | Product Catalogue 2014 31 Shop 32 Product Catalogue 2014 | BAG electronics Shop LED-modules →Lowmaintenanceandoperationcostsduetolong lifetimeandhighefficiencyofmodules →Highqualitylightforextendentvisualcomfort →Idealforcontinuouslineluminaires Components for LED applications ASTARES linear 2nd Generation ›Page94 BAG electronics | Product Catalogue 2014 33 Shop 34 Product Catalogue 2014 | BAG electronics Shop Compact LED-ECG for independent use. →PowerandoutputcurrentrangeoptimizedforLEDpointlightsources →SELVoutputvoltageallowsasimplifiedandsafetyluminaire construction →IndependentinstallationofECGforfiligreeluminairedesign Components for LED applications ZITARES UCS ›Page54 BAG electronics | Product Catalogue 2014 35 Shop 36 Product Catalogue 2014 | BAG electronics Shop Control gear for FL BCS TC TWINGLE High performance in a compact construction. →FullflexibilityandreductionofECGvarietyduetoMulti-power technologycombinedwithtwinglefuncionality →Optimalmaintenanceefficiencyandreliabilitybasedona max.lifetimeof100.000operatinghourstogetherwith BAG5yearswarranty →BestavailableenergyefficiencyclassEEI=A2BAT ›Page126 BAG electronics | Product Catalogue 2014 37 Sustainable and safe Light for outdoors Outdoor 38 Lightgeneratesatmosphereandalsogivesa senseofsafety,especiallyonroads,townplazas andinlargesportsarenas.Lightingsolutionsfor outdoorapplicationsmustmainlybereliablein allsituations.BAGsuppliescustom-designed lightingelectronics,andconstructedforthe completespectrumofapplicationsectors. Modernlightalsocutscostsandprotectsour naturalresources,andwithpubliclightingthe potentialforsavingisenormous. Product Catalogue 2014 | BAG electronics Outdoor BAG electronics | Product Catalogue 2014 39 Outdoor 40 Product Catalogue 2014 | BAG electronics Outdoor Efficient LED modules with linear design. →Lowmaintenanceandoperationcostsduetolonglifetimeand highefficiencyofmodules →Optimizedthermalmanagementforuseinroughenvironments →Non-SELVoperationforcostoptimizedsystemdesign →Idealforandwaterproofluminaires Components for LED applications ASTARES linear ›Page94 BAG electronics | Product Catalogue 2014 41 Outdoor 42 Product Catalogue 2014 | BAG electronics Outdoor Outdoor LED control gear units. →Adjustableoutputcurrentforflexibleandfuture-proofoperation ofLEDmodules →Longlifetimeandexcellentreliabilitytogetherwith BAG5yearwarranty →Highenergyefficiencyandmultiplecontrolfunctionalities fordemand-actuatedstreetlightingapplications →LEDprotectgivesafullsystemprotectionagainstovervoltages Components for LED applications ZITARES OCD ›Page92 BAG electronics | Product Catalogue 2014 43 Outdoor 44 Product Catalogue 2014 | BAG electronics Outdoor →FullflexibilityandreductionofECGvarietyduetoT5&T8 Multi-Powertechnology →Optimalmaintenanceefficiencyandreliabilitybasedona max.lifetimeof100.000operatinghourstogetherwith BAG5yearswarranty →BestavailableenergyefficiencyclassEEI=A2BAT →Suitableforuseintemperature-criticaloutdoorapplications Control gear for FL BCS Primus for T5 / T8 lamps ›Page118 BAG electronics | Product Catalogue 2014 45 46 Product Catalogue 2014 | BAG electronics Components for LED applications Electronic control units ZITARES ED ZITARES UCS ZITARES CCS ZITARES CCD ZITARES CCS 2nd Generation ZITARES CCD 2nd Generation ZITARES CCS ZITARES CCD ZITARES CCS ZITARES CCD ZITARES CCS 2nd Generation ZITARES ICD ZITARES CCS ZITARES CCD ZITARES NCS ZITARES LCS ZITARES NCS 2nd Generation ZITARES NCD 2nd Generation ZITARES OCS 1-Channel | non-dimmable | SELV| compact ................... 52 1-Channel | non-dimmable | SELV | independent ............ 54 1-Channel | non-dimmable | SELV | compact .................. 56 1-Channel | dimmable | SELV | compact ............................58 1-Channel | non-dimmable | SELV | linear........................60 1-Channel | dimmable | SELV | linear .................................. 62 2-Channel | non-dimmable r | SELV| linear ....................... 64 2-Channel | dimmable | SELV| linear .................................. 66 2-Channel | non-dimmable | SELV | compact..................68 2-Channel | dimmable | SELV| compact ............................. 70 2-Channel | dimmable | SELV | linear...................................72 2-Channel | dimmable | SELV | linear...................................74 4-Channel | non-dimmable | SELV | linear ........................76 4-Channel | dimmable | SELV | linear ................................ 78 1-Channel | non-dimmable | non-SELV | PCB ................. 82 1-Channel | non-dimmable | non-SELV | linear .............. 84 1-Channel | non-dimmable | non-SELV | linear ..............86 1-Channel | dimmable | non-SELV | linear .........................88 1-Channel | non-dimmable | non-SELV | outdoor ..........90 ZITARES OCD 1-Channel | dimmable | non-SELV | outdoor..................... 92 ASTARES linear 2nd Generation ASTARES plane 2nd Generation LED-Module | high performance | linear ............................ 94 LED-Module | high performance | plane ............................ 96 LED Light Engine NEXARES 2nd Generation LED Light-Engines | All-in-one | round ..............................98 BAG electronics | Product Catalogue 2014 Components for LED applications LED Module 47 Productfinder - Selection table Electronic control gear units LED Components 48 Model Order Number Output [mA] SELV ≤ 60V Power [W] Supply Voltage Dim lxwxh [mm] Page ED 10W/350mA HMC 10096231 1 x 350 ∙ 10 220 ... 240 V; 0/50…60 Hz - 80 x 40 x 22 52 UCS135-20LI-11/100-240 10092212 1 x 350 ∙ 20 100 ... 240 V; 50…60 Hz - 140 x 45 x 25 54 UCS150-20LI-11/100-240 10106905 1 x 500 ∙ 20 100 ... 240 V; 50…60 Hz - 140 x 45 x 25 54 UCS170-20LI-11/100-240 10092215 1 x 700 ∙ 20 100 ... 240 V; 50…60 Hz - 140 x 45 x 25 54 UCS170-35LI-11/100-240 10092218 1 x 700 ∙ 35 100 ... 240 V; 50…60 Hz - 140 x 45 x 31 54 UCS1105-50LI-11/100-240/ AUX 10112613 1 x 1050 ∙ 50 100 ... 240 V; 50…60 Hz - 153 x 49 x 33 54 CCS135-18QS-01/220-240 10078982 1 x 350 ∙ 18 220 ... 240 V; 0/50…60 Hz - 123 x 79 x 22 56 CCS170-35QS-01/220-240 10078983 1 x 700 ∙ 35 220 ... 240 V; 0/50…60 Hz - 123 x 79 x 22 56 CCD135-18QS-01/220-240/1–10V 10078978 1 x 350 ∙ 18 220 ... 240 V; 0/50…60 Hz 1-10 V 123 x 79 x 22 58 CCD135-18QS-01/220-240/DALI 10078979 1 x 350 ∙ 18 220 ... 240 V; 0/50…60 Hz DALI / Push-Dim 123 x 79 x 22 58 CCD170-35QS-01/220-240/1–10V 10078980 1 x 700 ∙ 35 220 ... 240 V; 0/50…60 Hz 1-10 V 123 x 79 x 22 58 CCD170-35QS-01/220-240/DALI 10078981 1 x 700 ∙ 35 220 ... 240 V; 0/50…60 Hz DALI / Push-Dim 123 x 79 x 22 58 CCS1100-50FR-20/200-240 10116434 1 x 500 … 1000 ∙ 50 220 ... 240 V; 0/50…60 Hz - 360 x 30 x 21 60 CCS1150-50FR-20/200-240 10116440 1 x 1000 … 1500 ∙ 50 220 ... 240 V; 0/50…60 Hz - 360 x 30 x 21 60 CCD1100-50FR-20/200-240/DALI 10116437 1 x 500 … 1000 ∙ 50 220 ... 240 V; 0/50…60 Hz DALI / Push-Dim 360 x 30 x 21 62 CCD1150-50FR-20/200-240/DALI 10116443 1 x 1000 … 1500 ∙ 50 220 ... 240 V; 0/50…60 Hz DALI / Push-Dim 360 x 30 x 21 62 CCS235-35LS-01/220-240 10078966 2 x 350 ∙ 35 220 ... 240 V; 0/50…60 Hz - 280 x 39 x 21 64 CCS250-50LS-01/220-240 10105112 2 x 500 ∙ 50 220 ... 240 V; 0/50…60 Hz - 280 x 39 x 21 64 CCS270-70LS-01/220-240 10078973 2 x 700 ∙ 70 220 ... 240 V; 0/50…60 Hz - 280 x 39 x 21 64 CCS235-35QS-01/220-240 10094454 2 x 350 ∙ 35 220 ... 240 V; 0/50…60 Hz - 135 x 75 x 21 68 CCS250-50QS-01/220-240 10098196 2 x 500 ∙ 50 220 ... 240 V; 0/50…60 Hz - 135 x 75 x 21 68 CCS270-70QS-01/220-240 10094457 2 x 700 ∙ 70 220 ... 240 V; 0/50…60 Hz - 135 x 75 x 21 68 CCD235-35LS-01/220-240/1–10V 10078992 2 x 350 ∙ 35 220 ... 240 V; 0/50…60 Hz 1-10 V 280 x 39 x 21 66 CCD235-35LS-01/220-240/DALI 10078993 2 x 350 ∙ 35 220 ... 240 V; 0/50…60 Hz DALI / Push-Dim 280 x 39 x 21 66 CCD250-50LS-01/220-240/DALI 10105113 2 x 500 ∙ 50 220 ... 240 V; 0/50…60 Hz DALI / Push-Dim 280 x 39 x 21 66 CCD270-70LS-01/220-240/1–10V 10078996 2 x 700 ∙ 70 220 ... 240 V; 0/50…60 Hz 1-10 V 280 x 39 x 21 66 CCD270-70LS-01/220-240/DALI 10078997 2 x 700 ∙ 70 220 ... 240 V; 0/50…60 Hz DALI / Push-Dim 280 x 39 x 21 66 CCD235-35QS-01/220-240/DALI 10094460 2 x 350 ∙ 35 220 ... 240 V; 0/50…60 Hz DALI / Push-Dim 135 x 75 x 21 70 CCD250-50QS-01/220-240/DALI 10098207 2 x 500 ∙ 50 220 ... 240 V; 0/50…60 Hz DALI / Push-Dim 135 x 75 x 21 70 CCD270-70QS-01/220-240/DALI 10094463 2 x 700 ∙ 70 220 ... 240 V; 0/50…60 Hz DALI / Push-Dim 135 x 75 x 21 70 Product Catalogue 2014 | BAG electronics Output [mA] SELV ≤ 60V Power [W] Supply Voltage Dim lxwxh [mm] Page CCD290-60FR-20/200-240/DALI 10116445 2 x 250 … 900 ∙ 60 220 ... 240 V; 0/50…60 Hz DALI / Push-Dim 360 x 30 x 21 72 CCD290-100FR-20/200-240/DALI 10116447 2 x 250 … 900 ∙ 100 220 ... 240 V; 0/50…60 Hz DALI / Push-Dim 360 x 30 x 21 72 ICD290-60LS-01/220-240/DALI 10105905 2 x 250 … 900 ∙ 60 220 ... 240 V; 0/50…60 Hz DALI / Push-Dim / DRI 360 x 30 x 21 74 ICD290-100LS-01/220-240/DALI 10105906 2 x 250 … 900 ∙ 100 220 ... 240 V; 0/50…60 Hz DALI / Push-Dim / DRI 360 x 30 x 21 74 CCS435-70LS-01/220-240 10078975 4 x 350 ∙ 70 220 ... 240 V; 0/50…60 Hz - 360 x 39 x 21 76 CCS470-140LS-01/220-240 10078977 4 x 700 ∙ 140 220 ... 240 V; 0/50…60 Hz - 360 x 39 x 21 76 CCD435-70LS-01/220-240/1–10V 10079000 4 x 350 ∙ 70 220 ... 240 V; 0/50…60 Hz 1-10 V 360 x 39 x 21 78 CCD435-70LS-01/220-240/DALI 10079001 4 x 350 ∙ 70 220 ... 240 V; 0/50…60 Hz DALI / Push-Dim 360 x 39 x 21 78 CCD470-140LS-01/220-240/1–10V 10079004 4 x 700 ∙ 140 220 ... 240 V; 0/50…60 Hz 1-10 V 360 x 39 x 21 78 CCD470-140LS-01/220-240/DALI 10079005 4 x 700 ∙ 140 220 ... 240 V; 0/50…60 Hz DALI / Push-Dim 360 x 39 x 21 78 NCS170-60LP-01/220-240 10091635 1 x 700 - 60 220 ... 240 V; 0/50…60 Hz - 255 x 28 x 26 82 LCS135-70FX-01/220-240 10116496 1 x 350 - 70 220 ... 240 V; 50…60 Hz - 280 x 30 x 21 84 LCS150-70FX-01/220-240 10116500 1 x 500 - 70 220 ... 240 V; 50…60 Hz - 280 x 30 x 21 84 LCS170-70FX-01/220-240 10116504 1 x 700 - 70 220 ... 240 V; 50…60 Hz - 280 x 30 x 21 84 NCS135-70FX-20/220-240 10112200 1 x 120 … 350 - 70 220 ... 240 V; 0/50…60 Hz - 280 x 30 x 21 86 NCS180-100FX-20/220-240 10112201 1 x 350 … 800 - 100 220 ... 240 V; 0/50…60 Hz - 280 x 30 x 21 86 NCD135-70FX-20/220-240/DALI 10116488 1 x 120 … 350 - 70 220 ... 240 V; 0/50…60 Hz DALI / Push-Dim 280 x 30 x 21 88 NCD180-100FX-20/220-240/DALI 10116492 1 x 350 … 800 - 100 220 ... 240 V; 0/50…60 Hz DALI / Push-Dim 280 x 30 x 21 88 OCS170-40LS-01 / 220-240 10111551 1 x 500 / 600 / 700 ∙ 40 220 ... 240 V; 50…60 Hz - 184 x 59 x 36 90 OCS170-80LS-01 / 220-240 10111552 1 x 500 / 600 / 700 ∙ 80 220 ... 240 V; 50…60 Hz - 184 x 59 x 36 90 OCS170-150LS-01 / 220-240 10111553 1 x 500 / 600 / 700 - 150 220 ... 240 V; 50…60 Hz - 235 x 59 x 39 90 OCS1140-80LS-01 / 220-240 10116782 1 x 1050 / 1200 / 1400 ∙ 80 220 ... 240 V; 50…60 Hz - 184 x 59 x 36 90 OCS1140-150LS-01 / 220-240 10116783 1 x 1050 / 1200 / 1400 - 150 220 ... 240 V; 50…60 Hz - 235 x 59 x 39 90 OCD180-40LS-01 / 220-240 / DALI 10111554 1 x 350 … 750 ∙ 40 220 ... 240 V; 50…60 Hz DALI / CP / geoDIM 184 x 59 x 39 92 OCD180-80LS-01 / 220-240 / DALI 10111555 1 x 350 … 750 ∙ 80 220 ... 240 V; 50…60 Hz DALI / CP / geoDIM 184 x 59 x 39 92 OCD180-160LS-01 / 220-240 / DALI 10111556 1 x 350 … 750 - 150 220 ... 240 V; 50…60 Hz DALI / CP / geoDIM 235 x 59 x 39 92 BAG electronics | Product Catalogue 2014 Productfinder - Selction LED EVG Order Number LED Components Model 49 Productfinder - Selection table LED Modules Model Order Number LMC-AS-110-830-LP-20 / L28W4 10107824 Light output [lm] Colour code 1050 1100 10107825 2100 10107826 2200 10107827 4 350 mA / 12 VDC 8 700 mA /12 VDC 4 350 mA / 12 VDC 16 700 mA /24 VDC 8 350 mA / 24 VDC 16 700 mA /24 VDC 8 350 mA / 24 VDC 840 1100 Productfinder - Selection LED Modules lxwxh [mm] Page 280 x 40 x 6 94 280 x 40 x 6 94 560 x 40 x 6 94 560 x 40 x 6 94 LMC-AS-120-840-PP-20 10112594 1250 830 8 700 mA /12 VDC 259 x 250 x 6 96 LMC-AS-120-830-PP-20 10112595 1200 840 8 700 mA /12 VDC 259 x 250 x 6 96 LMM-NE-110-830-RP-02 10108580 1300 830 10 220 ... 240 VAC Ø 190 x 8 98 LMM-NE-110-840-RP-02 10108581 1300 840 10 220 ... 240 VAC Ø 190 x 8 98 LMM-NE-200-830-RP-02 10108582 2000 830 16 220 ... 240 VAC Ø 240 x 8 98 LMM-NE-200-840-RP-02 10108583 2000 840 15 220 ... 240 VAC Ø 240 x 8 98 LED Components 50 700 mA /12 VDC 830 1050 LMC-AS-200-840-LP-20 / L56W4 8 840 550 LMC-AS-200-830-LP-20 / L56W4 Supply 830 550 LMC-AS-110-840-LP-20 / L28W4 Power Product Catalogue 2014 | BAG electronics BAG electronics | Product Catalogue 2014 51 ZITARES ED Non-dimmable constant current ECG for LED modules (SELV) with single channel output Electronic control gears | ZITARES ED Product information • Non-dimmable 1-channel ECG for constant current operation of LED modules • SELV equiv. output voltage ≤ 60 VDC • Efficiency of up to 90 % (100 % load) • Soft start and low output current ripple LED Components • ECG extensively protected against abnormal operating conditions at the output e.g. short-circuit, open circuit or overload • Suitable for direct current operation and application in combination with central battery installations • Compact housing for maximum flexibility in luminaire design • Certified as thermally protected device • Conformance with international regulations, regarding safety and operation, electromagnetic compatibility and immunity to interference • Nominal service life: 50,000 h with failure rate ≤ 10 % and operation at tc=tc,max Industry Office & Commercial Outdoor Shop Technical data Conformity EN 61347-1 Mains voltage supply Rated voltage range 220 ... 240 [V] EN 61347-2-13 Rated frequency 0 / 50 ... 60 [Hz] EN 62384 Admissible continuous voltage range (AC) 198 - 264 [VAC] EN 55015 Admissible continuous voltage range (DC) 198 ... 278 [VAC] Total harmonic distortion (THD) 15 %, at 100 % load EN 61547 Switch-off of the LEDs at overvoltage appr. 320 V Overvoltage protection (time) 350 V / 2 h Output data Constant current fixed Output current tolerance +/- 5 % Max. ripple output current +/- 10% Output voltage limitation 60 VDC; SELV equiv. Galvanic separation to mains input yes, test voltage 3.75 kV Max. starting time 0.5 s Dimming interfaces; depending on ECG model None Degree of protection Degree of protection Product Catalogue 2014 | BAG electronics IEC 60068-2-27 Behaviour at mains overvoltage Interfaces and dimming operation 52 IEC 60068-2-6 IP20 Designations Operating data Designation Material number No. of channels ED 10W/350mA HMC 10096231 1 Output current Output voltage Max. total output power Input current mA VDC W A 350 5 ... 30 10 0.12 Power factor ECG efficiency % 0.5 85 - All specifications with 230 VAC nominal operation and 100 % load Dimensions | weights | temperatures Short designation ED 10W / 350mA Length X Width Y Height Z Hole spacing XM (length direction) Weight Ambient temperature ta Housing temperature tc,max mm mm mm mm kg °C °C 80 40 22 70 0.045 -20 ... 50 85 Y Z Case drawing Electronic control gears | ZITARES ED XM X Wiring diagrams Connection of ECG input and output side + LED Components CH1 BAG electronics | Product Catalogue 2014 53 ZITARES UCS Non-dimmable constant current ECG for LED modules (SELV) with single channel output Electronic control gears | ZITARES UCS Product information • Non-dimmable 1-channel ECG for constant current operation of LED modules • SELV output voltage ≤ 60 VDC • High efficiency of up to 90 % (100 % load) • Wide range input voltage 100 – 240 VAC LED Components • For use in combination with luminaires of protection class I and II as independent device • ECG extensively protected against abnormal operating conditions at the output e.g. short-circuit, open circuit or overload Industry Office & Commercial Outdoor Shop Technical data Conformity EN 61347-1 Mains voltage supply Rated voltage range 100 ... 240 [V] EN 61347-2-13 Rated frequency 50 ... 60 [Hz] EN 62384 Admissible continuous voltage range (AC) 90 - 264 [VAC] EN 55015 Total harmonic distortion (THD) 15 %, at 100 % load EN 61547 Output data Constant current fixed Output current tolerance +/- 10 % • Certified as thermally protected device Max. ripple output current +/- 15 % • Conformance with international regulations, regarding safety and operation, electromagnetic compatibility and immunity to interference Output voltage limitation 60 VDC; SELV Galvanic separation to mains input yes, test voltage 3.75 kV Max. starting time 0.5 s • Nominal service life: 45,000 h with failure rate ≤ 10 % and operation at tc=tc,max Interfaces and dimming operation Dimming interfaces; depending on ECG model None Degree of protection Degree of protection 54 Product Catalogue 2014 | BAG electronics IP20 Designations Operating data Designation Material number No. of channels UCS135-20LI-11/100-240 10092212 1 UCS170-20LI-11/100-240 10092215 1 Output current Output voltage Max. total output power Input current Power factor ECG efficiency mA VDC W A 350 28 ... 58 20 0.22 0.9 85 700 14 ... 29 20 0.22 0.9 85 % UCS170-35LI-11/100-240 10092218 1 700 25 ... 51 35 0.38 0.9 85 UCS150-20LI-11/100-240 10106905 1 500 27 ... 40 20 0.22 0.9 85 1 1050 36 ... 48 50 0.62 0.9 85 Width Y Height Z Hole spacing XM (length direction) Hole spacing YM (width direction) Weight Ambient temperature ta Housing temperature tc,max UCS1105-50LI-11/100-240/ 10112613 AUX - All specifications with 230 VAC nominal operation and 100 % load Dimensions | weights | temperatures Short designation Length X mm mm mm mm mm kg °C °C UCS135-20LI-11... 140 45 25 133 37 0.130 -25 ... 50 80 UCS170-20LI-11... 140 45 25 133 37 0.130 -25 ... 50 80 UCS170-35LI-11... 140 45 31 133 37 0.155 -25 ... 50 80 UCS150-20LI-11... 140 45 25 133 37 0.130 -25 ... 50 80 UCS1105-50LI-11... 153 49 33 145 41 0.285 -25 ... 50 80 Electronic control gears | ZITARES UCS Y YM Case drawing XM X Wiring diagrams CH1 LED Components Connection of ECG input and output side + – BAG electronics | Product Catalogue 2014 55 ZITARES CCS Non-dimmable constant current ECG for LED modules (SELV) with single channel output Electronic control gears | ZITARES CCS Product information • Non-dimmable 1-channel ECG for constant current operation of LED modules • SELV equiv. output voltage ≤ 60 VDC • Very high efficiency of up to 90 % (100 % load) • Soft start and low output current ripple • For use in luminaires of protection class I LED Components • ECG extensively protected against abnormal operating conditions at the output e.g. short-circuit, open circuit or overload • Suitable for direct current operation and application in combination with central battery installations • Compact housing for maximum flexibility in luminaire design • Identical dimensions for dimmable and non-dimmable versions • Certified as thermally protected device • Conformance with international regulations, regarding safety and operation, electromagnetic compatibility and immunity to interference • Nominal service life: 50,000 h with failure rate ≤ 10 % and operation at tc=tc,max Industry Office & Commercial Outdoor Shop Technical data Conformity EN 61347-1 Mains voltage supply Rated voltage range 220 ... 240 [V] EN 61347-2-13 Rated frequency 0 / 50 ... 60 [Hz] EN 62384 Admissible continuous voltage range (AC) 198 - 264 [V] EN 61547 Admissible continuous voltage range (DC) 198 ... 278 [V] Max. leakage current 0.5 mA Total harmonic distortion (THD) 10 %, at 100 % load EN 55015 Switch-off of the LEDs at overvoltage appr. 320 VAC Overvoltage protection (time) 350 VAC / 2 h Output data Designations Constant current fixed Output current tolerance +/- 5% Max. ripple output current +/- 10% Output voltage limitation 60 VDC; SELV equiv. Galvanic separation to mains input yes, test voltage 3.75 kV Max. starting time 0.5 s Dimming interfaces; depending on ECG model None Degree of protection Degree of protection Product Catalogue 2014 | BAG electronics IEC 60068-2-27 Behaviour at mains overvoltage Interfaces and dimming operation 56 IEC 60068-2-6 IP20 Operating data Designation Material number No. of channels Output current Output voltage Max. total output power Input current CCS135-18QS-01/220-240 10078982 1 CCS170-35QS-01/220-240 10078983 Power factor ECG efficiency mA VDC W A 350 10 ... 50 18 0.19 0.95 88 1 700 10 ... 50 35 0.38 0.95 90 Width Y Height Z Hole spacing XM (length direction) Hole spacing YM (width direction) Weight Ambient temperature ta Housing temperature tc,max % - All specifications with 230 VAC nominal operation and 100 % load Dimensions | weights | temperatures Short designation Length X mm mm mm mm mm kg °C °C CCS1...18QS-01... 123 79 22 111 67 0.170 -25 ... 55 75 CCS1...35QS-01... 123 79 22 111 67 0.170 -25 ... 50 75 Electronic control gears | ZITARES CCS YM Y Z Case drawing XM X Wiring diagrams Connection of ECG input and output side PE L N + – LED Components CH1 more ECG BAG electronics | Product Catalogue 2014 57 ZITARES CCD Dimmable constant current ECG for LED modules (SELV) with single channel output Electronic control gears | ZITARES CCD Product information • Dimmable 1-channel ECG for constant current operation of LED modules • SELV equiv. output voltage ≤ 60 VDC • Very high efficiency of up to 90 % (100 % load) • Soft start and low output current ripple • For use in luminaires of protection class I LED Components • ECG extensively protected against abnormal operating conditions at the output e.g. short-circuit, open circuit or overload • Suitable for direct current operation and application in combination with central battery installations • Overvoltage protection of the DALI and 1–10 V interfaces up to 264 VAC • Push-Dim function of DALI interface: switching and dimming via push-button • Settable recovery function: automatic switch-on after mains failure • Dimming range: 1 ... 100 % luminous flux • PWM dimming with 500 Hz for flicker-free light and prevention of stroboscopic effects • Compact housing for maximum flexibility in luminaire design • Identical dimensions for dimmable and non-dimmable versions Office & Commercial Outdoor Shop Technical data Conformity EN 61347-1 Mains voltage supply Rated voltage range 220 ... 240 [V] EN 61347-2-13 Rated frequency 0 / 50 ... 60 [Hz] EN 62384 Admissible continuous voltage range (AC) 198 - 264 [V] EN 61547 Admissible continuous voltage range (DC) 198 ... 278 [V] Max. leakage current 0.5 mA Total harmonic distortion (THD) 10 %, at 100 % load EN 55015 Switch-off of the LEDs at overvoltage appr. 320 VAC Overvoltage protection (time) 350 VAC / 2 h Output data IEC 60068-2-6 IEC 60068-2-27 Designations Constant current fixed Output current tolerance +/- 5% Max. ripple output current +/- 10% Output voltage limitation 60 VDC; SELV equiv. Galvanic separation to mains input yes, test voltage 3.75 kV Max. starting time 0.5 s Interfaces and dimming operation Dimming interfaces; depending on ECG model 1-10V, DALI, Push-Dim Dimming range • Conformance with international regulations, regarding safety and operation, electromagnetic compatibility and immunity to interference Dimming technology PWM Max. Stand-by power (DALI & Push-Dim) 0.3 W Max. number of ECGs (Push-Dim) 25 Max. control current (1-10V) 0.6 mA 1...100% Degree of protection Degree of protection Product Catalogue 2014 | BAG electronics EN 62386-102 Behaviour at mains overvoltage • Certified as thermally protected device • Nominal service life: 50,000 h with failure rate ≤ 10 % and operation at tc=tc,max 58 Industry IP20 Operating data Designation Material number No. of channels Output current Output voltage Max. total output power Input current CCD135-18QS-01/ 220-240/1-10V 10078978 1 CCD135-18QS-01/ 220-240/DALI 10078979 CCD170-35QS-01/ 220-240/1-10V CCD170-35QS-01/ 220-240/DALI Power factor ECG efficiency mA VDC W A 350 10 ... 50 18 0.19 0.95 88 1 350 10 ... 50 18 0.19 0.95 88 10078980 1 700 10 ... 50 35 0.38 0.95 90 10078981 1 700 10 ... 50 35 0.38 0.95 90 Hole spacing XM (length direction) Hole spacing YM (width direction) Weight Ambient temperature ta Housing temperature tc,max % - All specifications with 230 VAC nominal operation and 100 % load - Power output in undimmed operation should not go below 20 % of the maximum permissible value Short designation Length X Width Y Height Z mm mm mm mm mm kg °C °C CCD1...18QS-01... / 1-10V 123 79 22 111 67 0.175 -25 ... 55 75 CCD1...18QS-01... / DALI 123 79 22 111 67 0.175 -25 ... 55 75 CCD1...35QS-01... / 1-10V 123 79 22 111 67 0.175 -25 ... 50 75 CCD1...35QS-01... / DALI 123 79 22 111 67 0.175 -25 ... 50 75 YM Y Z Case drawing XM X Wiring diagrams PE CH1 L 3 - Connection of ECG input and output side side for 1 - 10V control N + – DA DA DA DA more ECGs PE CH1 + – 1-10 V + – 1-10 V + – L N LED Components 1 - Connection of ECG input and output side for DALI control Electronic control gears | ZITARES CCD Dimensions | weights | temperatures more ECGs 2 - Connection of ECG input and output side for control via push-button PE CH1 L N + – Push-DIM DA DA L more ECGs BAG electronics | Product Catalogue 2014 59 ZITARES CCS 2nd Generation Non-dimmable constant current ECG for LED modules (SELV) with adjustable single channel output Electronic control gears | ZITARES CCS 2nd Generation Product information • Non-dimmable 1-channel ECG for constant current operation of LED modules • Adjustable output currents by plug-in of resistors (LEDset) • SELV equiv. output voltage ≤ 60 VDC • Very high efficiency of up to 90 % (100 % load) LED Components • Soft start and low output current ripple • For use in luminaires of protection class I • ECG extensively protected against abnormal operating conditions at the output e.g. short-circuit, open circuit or overload • Suitable for direct current operation and application in combination with central battery installations • Compact housing for maximum flexibility in luminaire design • Identical dimensions for dimmable and non-dimmable versions • Certified as thermally protected device • Conformance with international regulations, regarding safety and operation, electromagnetic compatibility and immunity to interference • Nominal service life: 50,000 h with failure rate ≤ 10 % and operation at tc=tc,max Industry Office & Commercial Outdoor Shop Technical data Conformity EN 61347-1 Mains voltage supply Rated voltage range 220 ... 240 [V] EN 61347-2-13 Rated frequency 0 / 50 ... 60 [Hz] EN 62384 Admissible continuous voltage range (AC) 198 - 264 [V] EN 61547 Admissible continuous voltage range (DC) 198 ... 278 [V] Max. leakage current 0.5 mA Total harmonic distortion (THD) 10 %, at 100 % load EN 55015 Switch-off of the LEDs at overvoltage appr. 320 VAC Overvoltage protection (time) 350 VAC / 2 h Output data Designations Constant current adjustable Output current tolerance +/- 5 % Max. ripple output current +/- 10% Output voltage limitation 60 VDC; SELV equiv. Galvanic separation to mains input yes, test voltage 3.75 kV Max. starting time 0.5 s Interfaces and dimming operation Sensor interface LEDset None Degree of protection Degree of protection Product Catalogue 2014 | BAG electronics IEC 60068-2-27 Behaviour at mains overvoltage Dimming interfaces; depending on ECG model 60 IEC 60068-2-6 IP20 Operating data Designation Material number No. of channels Output current range (default) Output voltage Max. total output power Input current Power factor ECG efficiency mA VDC W A CCS1100-50FR-20/220-240 10116434 1 500 ... 1000 (700) 22 ... 55 50 0.27 0.98 % 90 CCS1150-50FR-20/220-240 10116440 1 1000 ... 1500 (1400) 13 ... 50 50 0.27 0.98 90 Width Y Height Z Hole spacing XM (length direction) Hole spacing ZM (height direction) Weight Ambient temperature ta Housing temperature tc,max - All specifications with 230 VAC nominal operation and 100 % load - Available as of Q3/2014 Dimensions | weights | temperatures Short designation Length X mm mm mm mm mm kg °C °C CCS1100-50FR-20... 360 30 21 350 9 0.250 -25 ... 50 75 CCS1150-50FR-20... 360 30 21 350 9 0.250 -25 ... 50 75 Y Z ZM Electronic control gears | ZITARES CCS 2nd Generation Case drawing XM X Wiring diagrams 1 - Connection of ECG output side LEDset + – ohmic ohmic resistor LED Components CH1: LED A - Connection of ECG input side L N PE more ECGs BAG electronics | Product Catalogue 2014 61 ZITARES CCD 2nd Generation Dimmable constant current ECG for LED modules (SELV) with adjustable single channel output Electronic control gears | ZITARES CCD 2 Generation Product information • Dimmable 1-channel ECG for constant current operation of LED modules • Adjustable output currents by plug-in of resistors (LEDset) or digital programming * • SELV equiv. output voltage ≤ 60 VDC • Very high efficiency of up to 90 % (100 % load) LED Components • Soft start and low output current ripple • For use in luminaires of protection class I • ECG extensively protected against abnormal operating conditions at the output e.g. short-circuit, open circuit or overload • Suitable for direct current operation and application in combination with central battery installations • Overvoltage protection of the DALI interface up to 264 VAC Office & Commercial Outdoor Shop Technical data Conformity EN 61347-1 Mains voltage supply Rated voltage range 220 ... 240 [V] EN 61347-2-13 Rated frequency 0 / 50 ... 60 [Hz] EN 62384 Admissible continuous voltage range (AC) 198 - 264 [V] EN 61547 Admissible continuous voltage range (DC) 198 ... 278 [V] Max. leakage current 0.5 mA Total harmonic distortion (THD) 10 %, at 100 % load EN 55015 Switch-off of the LEDs at overvoltage appr. 320 VAC Overvoltage protection (time) 350 VAC / 2 h Output data • Push-Dim function of DALI interface: switching and dimming via push-button Output current tolerance +/- 5 % • Settable recovery function: automatic switch-on after mains failure Max. ripple output current +/- 10% Output voltage limitation 60 VDC; SELV equiv. Galvanic separation to mains input yes, test voltage 3.75 kV Max. starting time 0.5 s • Compact housing for maximum flexibility in luminaire design • Identical dimensions for dimmable and non-dimmable versions • Certified as thermally protected device • Conformance with international regulations, regarding safety and operation, electromagnetic compatibility and immunity to interference • Nominal service life: 50,000 h with failure rate ≤ 10 % and operation at tc=tc,max * Programming via software ZITARES 360 Product Catalogue 2014 | BAG electronics Interfaces and dimming operation Sensor interface Dimming interfaces; depending on ECG model LEDset DALI, Push-Dim Dimming range 1...100% Dimming technology PWM Max. Stand-by power (DALI & Push-Dim) 0.3 W Max. number of ECGs (Push-Dim) 25 Degree of protection Degree of protection EN 62386-207 IEC 60068-2-6 Designations adjustable • PWM dimming with 500 Hz for flicker-free light and prevention of stroboscopic effects EN 62386-102 IEC 60068-2-27 Behaviour at mains overvoltage Constant current • Dimming range: 1 ... 100 % luminous flux 62 Industry IP20 Operating data Designation Material number No. of channels CCD1100-50FR-20/ 220-240/DALI 10116437 1 CCD1150-50FR-20/ 220-240/DALI 10116443 1 Output current range (default) Output voltage Max. total output power Input current Power factor ECG efficiency mA VDC W A 500 ... 1000 (700) 22 ... 55 50 0.27 0.98 90 1000 ... 1500 (1400) 13 ... 50 50 0.27 0.98 90 % - All specifications with 230 VAC nominal operation and 100 % load - Power output in undimmed operation should not go below 40 % of the maximum permissible value - Available as of Q4/2014 Dimensions | weights | temperatures Short designation Length X Width Y Height Z Hole spacing XM (length direction) Hole spacing ZM (height direction) Weight Ambient temperature ta Housing temperature tc,max mm mm mm mm mm kg °C °C CCD1100-50FR-20... / DALI 360 30 21 350 9 0.260 -25 ... 50 75 CCD1150-50FR-20... / DALI 360 30 21 350 9 0.260 -25 ... 50 75 Y Z ZM Electronic control gears | ZITARES CCD 2nd Generation Case drawing XM X Wiring diagrams 1 - Connection of ECG output side C - Connection ECG-Programming Box for programming Software ZITARES 360 USB L LEDset DA Programming Box DA + – ohmic ohmic resistor LED Components CH1: LED N PE n.c. DA DA A - Connection of ECG input side for DALI control PE L N DA DA n.c. DA DA more ECG B - Connection of ECG input side for control via push-button L N PE n.c. DA DA Push-DIM more ECG BAG electronics | Product Catalogue 2014 63 ZITARES CCS Non-dimmable constant current ECG for LED modules (SELV) with 2 channel output Electronic control gears | ZITARES CCS Product information • Non-dimmable 2-channel ECG for constant current operation of LED modules • Asymmetrical load for the output channels is admissible • Selection of additional output currents by means of parallel connection of the output channels • SELV equiv. output voltage ≤ 60 VDC LED Components • Very high efficiency of up to 91 % (100 % load) • Soft start and low output current ripple • For use in luminaires of protection class I • ECG extensively protected against abnormal operating conditions at the output e.g. short-circuit, open circuit or overload • Suitable for direct current operation and application in combination with central battery installations • Compact housing for maximum flexibility in luminaire design • Identical dimensions for dimmable and non-dimmable versions • Certified as thermally protected device • Conformance with international regulations, regarding safety and operation, electromagnetic compatibility and immunity to interference • Nominal service life: 50,000 h with failure rate ≤ 10 % and operation at tc=tc,max Industry Office & Commercial Outdoor Shop Technical data Conformity EN 61347-1 Mains voltage supply Rated voltage range 220 ... 240 [V] EN 61347-2-13 Rated frequency 0 / 50 ... 60 [Hz] EN 62384 Admissible continuous voltage range (AC) 198 - 264 [V] EN 61547 Admissible continuous voltage range (DC) 198 ... 278 [V] EN 55015 Max. leakage current 0.5 mA Total harmonic distortion (THD) 10 %, at 100 % load Behaviour at mains overvoltage Switch-off of the LEDs at overvoltage appr. 320 VAC Overvoltage protection (time) 350 VAC / 2 h Output data Designations Constant current fixed Output current tolerance +/- 5 % Max. ripple output current +/- 10% Output voltage limitation 60 VDC; SELV equiv. Galvanic separation to mains input yes, test voltage 3.75 kV Max. starting time 0.5 s Interfaces and dimming operation Dimming interfaces; depending on ECG model None Degree of protection Degree of protection 64 Product Catalogue 2014 | BAG electronics IEC 60068-2-27 IP20 Operating data Designation Material number No. of channels Output current Output voltage Max. total output power Input current CCS235-35LS-01/220-240 10078966 2 CCS250-50LS-01/220-240 10105112 CCS270-70LS-01/220-240 10078973 Power factor ECG efficiency mA VDC W A 350 10 ... 50 35 0.18 0.98 90 2 500 10 ... 50 50 0.18 0.98 90 2 700 10 ... 50 70 0.18 0.98 91 Hole spacing XM (length direction) Hole spacing ZM (height direction) Weight Ambient temperature ta Housing temperature tc,max % - All specifications with 230 VAC nominal operation and 100 % load - Power output in undimmed operation should not go below 20 % of the maximum permissible value - Asymmetric load distribution on the outputs is permissible - Further output currents can be selected via parallel switching of the ECG outputs, see the table „Current selection“ Dimensions | weights | temperatures Short designation Length X Width Y Height Z mm mm mm mm mm kg °C °C CCS2...35LS-01... 280 39 21 270 9 0.290 -25 ... 55 75 CCS2...50LS-01... 280 39 21 270 9 0.290 -25 ... 50 75 CCS2...70LS-01... 280 39 21 270 9 0.290 -25 ... 50 75 XM X 1 - Connection of ECG output side Current selection Output current 350 mA + – + CH2: LED – CH1: LED CCS23535LS··· CCS25050LS··· CCS27070LS··· 2x 500 mA 2x 700 mA 1x 2x 1.050 mA 1x 1.400 mA s. Wiring diagrams 1x 1 2 1 2 1 2 2 - Connection of ECG output side LED Components Wiring diagrams Electronic control gears | ZITARES CCS Y Z ZM Case drawing + – + CH2: LED – CH1: LED A - Connection of ECG input side PE L N more ECG BAG electronics | Product Catalogue 2014 65 ZITARES CCD Dimmable constant current ECG for LED modules (SELV) with 2 channel output Electronic control gears | ZITARES CCD Product information • Dimmable 2-channel ECG for constant current operation of LED modules • Selection of additional output currents by means of parallel connection of the output channels • SELV equiv. output voltage ≤ 60 VDC • Very high efficiency of up to 91 % (100 % load) LED Components • Soft start and low output current ripple • For use in luminaires of protection class I • ECG extensively protected against abnormal operating conditions at the output e.g. short-circuit, open circuit or overload • Suitable for direct current operation and application in combination with central battery installations • Overvoltage protection of the DALI and 1–10 V interfaces up to 264 VAC Office & Commercial Outdoor Shop Technical data Conformity EN 61347-1 Mains voltage supply Rated voltage range 220 ... 240 [V] EN 61347-2-13 Rated frequency 0 / 50 ... 60 [Hz] EN 62384 Admissible continuous voltage range (AC) 198 - 264 [V] EN 61547 Admissible continuous voltage range (DC) 198 ... 278 [V] Max. leakage current 0.5 mA Total harmonic distortion (THD) 10 %, at 100 % load EN 55015 Switch-off of the LEDs at overvoltage appr. 320 VAC Overvoltage protection (time) 350 VAC / 2 h Output data • Push-Dim function of DALI interface: switching and dimming via push-button Output current tolerance +/- 5 % • Settable recovery function: automatic switch-on after mains failure Max. ripple output current +/- 10% Output voltage limitation 60 VDC; SELV equiv. Galvanic separation to mains input yes, test voltage 3.75 kV Max. starting time 0.5 s • Compact housing for maximum flexibility in luminaire design • Identical dimensions for dimmable and non-dimmable versions • Certified as thermally protected device • Conformance with international regulations, regarding safety and operation, electromagnetic compatibility and immunity to interference • Nominal service life: 50,000 h with failure rate ≤ 10 % and operation at tc=tc,max Product Catalogue 2014 | BAG electronics Interfaces and dimming operation Dimming interfaces; depending on ECG model Dimming range 1-10V, DALI, Push-Dim 1...100% Dimming technology PWM Max. Stand-by power (DALI & Push-Dim) 0.3 W Max. number of ECGs (Push-Dim) 25 Max. control current (1-10V) 0,6 mA Degree of protection Degree of protection EN 62386-207 IEC 60068-2-6 Designations fixed • PWM dimming with 500 Hz for flicker-free light and prevention of stroboscopic effects EN 62386-102 IEC 60068-2-27 Behaviour at mains overvoltage Constant current • Dimming range: 1 ... 100 % luminous flux 66 Industry IP20 Operating data Designation Material number No. of channels Output current Output voltage Max. total output power Input current CCD235-35LS-01/ 220-240/1-10V 10078992 2 CCD235-35LS-01/ 220-240/DALI 10078993 CCD250-50LS-01/ 220-240/DALI Power factor ECG efficiency mA VDC W A 350 10 ... 50 35 0.18 0.98 90 2 350 10 ... 50 35 0.18 0.98 90 10105113 2 500 10 ... 50 50 0.27 0.98 90 CCD270-70LS-01/ 220-240/1-10V 10078996 2 700 10 ... 50 70 0.36 0.98 91 CCD270-70LS-01/ 220-240/DALI 10078997 2 700 10 ... 50 70 0.36 0.98 91 Hole spacing XM (length direction) Hole spacing ZM (height direction) Weight Ambient temperature ta Housing temperature tc,max % - All specifications with 230 VAC nominal operation and 100 % load - Power output in undimmed operation should not go below 20 % of the maximum permissible value - Asymmetric load distribution on the outputs is permissible - Further output currents can be selected via parallel switching of the ECG outputs, see the table „Current selection“ Short designation Length X Height Z mm mm mm mm mm kg °C °C CCD2...35LS-01... / 1-10V 280 39 21 270 9 0.295 -25 ... 55 75 CCD2...35LS-01... / DALI 280 39 21 270 9 0.295 -25 ... 55 75 CCD2...50LS-01... / DALI 280 39 21 270 9 0.295 -25 ... 50 75 CCD2...70LS-01... / 1-10V 280 39 21 270 9 0.295 -25 ... 50 75 CCD2...70LS-01... / DALI 280 39 21 270 9 0.295 -25 ... 50 75 Case drawing Current selection CCD23535LS··· Z ZM Output current 350 mA 2x 700 mA 2x 1x 1.050 mA XM CCD27070LS··· 2x 500 mA Y CCD25050LS··· 1x 1.400 mA X 1x 1 s. Wiring diagrams 2 1 2 1 2 Wiring diagrams 1 - Connection of ECG output side B - Connection of ECG input side for control via push-button PE L N + – + CH2: LED – CH1: LED DA DA Push-DIM LED Components Width Y Electronic control gears | ZITARES CCD Dimensions | weights | temperatures 2 - Connection of ECG output side more ECG + – + CH2: LED – CH1: LED C - Connection of ECG input side for 1 - 10V control L N PE – + – A - Connection of ECG input side for DALI control PE L + 1-10 V 1-10 V n.c. N DA DA DA DA n.c. more ECG more ECG BAG electronics | Product Catalogue 2014 67 ZITARES CCS Non-dimmable constant current ECG for LED modules (SELV) with 2 channel output Electronic control gears | ZITARES CCS Product information • Non-dimmable 2-channel ECG for constant current operation of LED modules • Asmmetrical load for the output channels is admissable • Selection of additional output currents by means of parallel connection of the output channels • SELV equiv. output voltage ≤ 60 VDC LED Components • Very high efficiency of up to 91 % • Soft start and low output ripple • For use in luminairs of protection class I • Comprehensive protection of the ECG against abnormal operating conditions at the output, e.g. short circuit, open circuit, overload • Suitable for direct current operation and application in combination with central battery installations • Housing in compact dimensions for installation in luminaires • Identical dimensions for DALI and non-dimmable versions • Certified as thermally protected device, e.g. for application in F-luminaires • Conformance with international regulations, regarding safety and operation, electromagnetic compatibility and immunity to interference • Nominal service life: 50,000 h with failure rate = 10 % and operation at tc=tc,max Product Catalogue 2014 | BAG electronics Office & Commercial Outdoor Shop Technical data Conformity EN 61347-1 Mains voltage supply Rated voltage range 220 ... 240 [V] EN 61347-2-13 Rated frequency 0 / 50 ... 60 [Hz] EN 62384 Admissible continuous voltage range (AC) 198 - 264 [V] EN 61547 Admissible continuous voltage range (DC) 198 ... 278 [V] Max. leakage current 0.5 mA Total harmonic distortion (THD) 10 %, at 100 % load EN 55015 IEC 60068-2-6 IEC 60068-2-27 Behaviour at mains overvoltage Switch-off of the LEDs at overvoltage appr. 320 VAC Overvoltage protection (time) 350 VAC / 2 h Output data Designations Constant current fixed Output current tolerance +/- 5 % Max. ripple output current +/- 10% Output voltage limitation 60 VDC; SELV equiv. Galvanic separation to mains input yes, test voltage 3.75 kV Max. starting time 0.5 s Interfaces and dimming operation Dimming interfaces; depending on ECG model None Degree of protection Degree of protection 68 Industry IP20 Operating data Designation Material number No. of channels Output current Output voltage Max. total output power Input current CCS235-35QS-01/220-240 10094454 2 CCS250-50QS-01/220-240 10098196 CCS270-70QS-01/220-240 10094457 Power factor ECG efficiency mA VDC W A 350 10 ... 50 35 0.18 0.98 90 2 500 10 ... 50 50 0.27 0.98 90 2 700 10 ... 50 70 0.36 0.98 91 Hole spacing XM (length direction) Hole spacing YM (width direction) Weight Ambient temperature ta Housing temperature tc,max % - All specifications with 230 VAC nominal operation and 100 % load - Power output in undimmed operation should not go below 20 % of the maximum permissible value - Asymmetric load distribution on the outputs is permissible - Further output currents can be selected via parallel switching of the ECG outputs, see the table „Current selection“ Dimensions | weights | temperatures Short designation Length X Width Y Height Z mm mm mm mm mm kg °C °C CCS2...35QS-01... 135 75 21 124 64 0.250 -25 ... 55 75 CCS2...50QS-01... 135 75 21 124 64 0.250 -25 ... 50 75 CCS2...70QS-01... 135 75 21 124 64 0.250 -25 ... 50 75 Current selection 1 - Connection of ECG output side Output current 350 mA CCS23535QS··· CCS25050QS··· 2x 500 mA 2x 700 mA 1x 2x 1.050 mA + – + CH2: LED – CH1: LED CCS27070QS··· 1x 1.400 mA s. Wiring diagrams 1x 1 2 1 2 1 2 2 - Connection of ECG output side LED Components Wiring diagrams Electronic control gears | ZITARES CCS Case drawing + – + CH2: LED – CH1: LED A - Connection of ECG input side PE + – + CH2: LED – CH1: LED L N ohmic resistor more ECG BAG electronics | Product Catalogue 2014 69 ZITARES CCD Dimmable constant current ECG for LED modules (SELV) with 2 channel output Electronic control gears | ZITARES CCD Product information • Dimmable 2-channel ECG for constant current operation of LED modules • Asmmetrical load for the output channels is admissable • Selection of additional output currents by means of parallel connection of the output channels • SELV equiv. output voltage ≤ 60 VDC LED Components • Very high efficiency of up to 91 % • Soft start and low output ripple • For use in luminairs of protection class I • Comprehensive protection of the ECG against abnormal operating conditions at the output, e.g. short circuit, open circuit, overload • Suitable for direct current operation and application in combination with central battery installations • Overvoltage protection of the DALI interface up to 264 VAC • Push-Dim function for DALI versions: dimming and switching via push-button, with memory function • Dimming range: 1 ... 100 % luminous flux • PWM dimming with 500 Hz for flicker-free light and prevention of stoboscopic effects • Housing in compact dimensions for installation in luminaires • Identical dimensions for DALI and non-dimmable versions • Certified as thermally protected device, e.g. for application in F-luminaires • Conformance with international regulations, regarding safety and operation, electromagnetic compatibility and immunity to interference • Nominal service life: 50,000 h with failure rate = 10 % and operation at tc=tc,max 70 Product Catalogue 2014 | BAG electronics Industry Office & Commercial Outdoor Shop Technical data Conformity EN 61347-1 Mains voltage supply Rated voltage range 220 ... 240 [V] EN 61347-2-13 Rated frequency 0 / 50 ... 60 [Hz] EN 62384 Admissible continuous voltage range (AC) 198 - 264 [V] EN 61547 Admissible continuous voltage range (DC) 198 ... 278 [V] Max. leakage current 0.5 mA Total harmonic distortion (THD) 10 %, at 100 % load EN 55015 Switch-off of the LEDs at overvoltage appr. 320 VAC Overvoltage protection (time) 350 VAC / 2 h Output data fixed Output current tolerance +/- 5 % Max. ripple output current +/- 10% Output voltage limitation 60 VDC; SELV equiv. Galvanic separation to mains input yes, test voltage 3.75 kV Max. starting time 0.5 s Interfaces and dimming operation DALI, Push-Dim 1...100% Dimming technology PWM Max. Stand-by power (DALI & Push-Dim) 0.3 W Max. number of ECGs (Push-Dim) 25 Degree of protection Degree of protection IEC 60068-2-6 Designations Constant current Dimming range EN 62386-207 IEC 60068-2-27 Behaviour at mains overvoltage Dimming interfaces; depending on ECG model EN 62386-102 IP20 Operating data Designation Material number No. of channels Output current Output voltage Max. total output power Input current CCD235-35QS-01/ 220-240/DALI 10094460 2 CCD250-0QS-01/ 220-240/DALI 10098207 CCD270-70QS-01/ 220-240/DALI 10094463 Power factor ECG efficiency mA VDC W A 350 10 ... 50 35 0.18 0.98 90 2 500 10 ... 50 50 0.27 0.98 90 2 700 10 ... 50 70 0.36 0.98 91 Hole spacing XM (length direction) Hole spacing YM (width direction) Weight Ambient temperature ta Housing temperature tc,max % - All specifications with 230 VAC nominal operation and 100 % load - Power output in undimmed operation should not go below 20 % of the maximum permissible value - Asymmetric load distribution on the outputs is permissible - Further output currents can be selected via parallel switching of the ECG outputs, see the table „Current selection“ Dimensions | weights | temperatures Short designation Length X mm mm mm mm mm kg °C °C CCD2...35QS-01... / DALI 135 75 21 124 64 0.255 -25 ... 55 75 CCD2...50QS-01... / DALI 135 75 21 124 64 0.255 -25 ... 50 75 CCD2...70QS-01... / DALI 135 75 21 124 64 0.255 -25 ... 50 75 Case drawing Height Z 10094460 Current selection Z Output current 350 mA CCD23535QS··· CCD25050QS··· 2x 500 mA 2x 700 mA 1x 2x 1.050 mA YM Y CCD27070QS··· 1x 1.400 mA 1x s. Wiring diagrams 1 2 1 2 1 2 XM X Wiring diagrams B - Connection of ECG input and output side for control via push-button PE + – + CH2: LED – L N LED Components 1 - Connection of ECG output side Electronic control gears | ZITARES CCD Width Y CH1: LED DA DA CH1: LED CH2: LED 2 - Connection of ECG input and output side + – + – more ECG + – + CH2: LED – CH1: LED A - Connection of ECG input and output side for DALI control PE L N DA DA DA DA + – + CH2: LED – CH1: LED more ECG BAG electronics | Product Catalogue 2014 71 ZITARES CCD 2nd Generation Dimmable constant current ECG for LED modules (SELV) with adjustable 2 channel output Electronic control gears | ZITARES CCD 2nd Generation Product information • Dimmable 2-channel ECG for constant current operation of LED modules Office & Commercial Outdoor Shop Technical data Conformity EN 61347-1 Mains voltage supply ED LEDKomponenten Components Rated voltage range 220 ... 240 [V] EN 61347-2-13 Rated frequency 0 / 50 ... 60 [Hz] EN 62384 • Selection of additional output currents by means of parallel connection of the output channels Admissible continuous voltage range (AC) 198 - 264 [V] EN 61547 • SELV equiv. output voltage ≤ 60 VDC Admissible continuous voltage range (DC) 198 ... 278 [V] Max. leakage current 0.5 mA Total harmonic distortion (THD) 10 %, at 100 % load • Adjustable output currents by plug-in of resistors or digital programming * • Very high efficiency of up to 91 % (100 % load) • Soft start and low output current ripple • For use in luminaires of protection class I • ECG extensively protected against abnormal operating conditions at the output e.g. short-circuit, open circuit or overload • Suitable for direct current operation and application in combination with central battery installations EN 55015 Switch-off of the LEDs at overvoltage appr. 320 VAC Overvoltage protection (time) 350 VAC / 2 h Output data • Overvoltage protection of the DALI interface up to 264 VAC Output current tolerance +/- 5 % • Push-Dim function of DALI interface: switching and dimming via push-button Max. ripple output current +/- 10% Output voltage limitation 60 VDC; SELV equiv. Galvanic separation to mains input yes, test voltage 3.75 kV Max. starting time 0.5 s • PWM dimming with 500 Hz for flicker-free light and prevention of stroboscopic effects • Compact housing for maximum flexibility in luminaire design • Certified as thermally protected device • Conformance with international regulations, regarding safety and operation, electromagnetic compatibility and immunity to interference • Nominal service life: 50,000 h with failure rate ≤ 10 % and operation at tc=tc,max * Programming via software ZITARES 360 Product Catalogue 2014 | BAG electronics Interfaces and dimming operation Sensor interface Dimming interfaces; depending on ECG model Rset DALI, Push-Dim Dimming range 1...100% Dimming technology PWM Max. Stand-by power (DALI & Push-Dim) 0.5 W Max. number of ECGs (Push-Dim) 25 Degree of protection Degree of protection EN 62386-207 IEC 60068-2-6 Designations adjustable • Dimming range: 1 ... 100 % luminous flux EN 62386-102 IEC 60068-2-27 Behaviour at mains overvoltage Constant current • Settable recovery function: automatic switch-on after mains failure 72 Industry IP20 Operating data Designation Material number No. of channels CCD290-60FR-20/ 220-240/DALI 10116445 2 CCD290-100FR-20/ 220-240/DALI 10116447 2 Output current range (default) Output voltage Max. total output power Input current Power factor ECG efficiency mA VDC W A 250 ... 900 (700) 10 ... 33 60 0.30 0.98 90 250 ... 900 (700) 25 ... 53 96 0.45 0.98 90 Hole spacing XM (length direction) Hole spacing ZM (height direction) Weight Ambient temperature ta Housing temperature tc,max % - All specifications with 230 VAC nominal operation and 100 % load - Power output in undimmed operation should not go below 40 % of the maximum permissible value - Asymmetric load distribution on the outputs is permissible - Further output currents can be selected via parallel switching of the ECG outputs, see the table „Current selection“ - Available as of Q2/2014 Short designation Length X Width Y Height Z mm mm mm mm mm kg °C °C CCD290-60FR-20... / DALI 360 30 21 350 9 0.315 -25 ... 50 75 CCD290-100FR-20... / DALI 360 30 21 350 9 0.315 -25 ... 50 75 Current selection Case drawing Z ZM Output current CCD290-60FR··· 250 ... 900 mA 2x Y 500 ... 1800 mA CCD290-100FR··· 2x 1x s. Wiring diagrams 1 2 1x 1 2 XM X Wiring diagrams 1 - Connection of ECG output side CH1: LED Rset PE L + N – LED LEDKomponenten Components CH2: LED B - Connection of ECG input and output side for control via push-button + DA – + – DA ohmic resistor Push-DIM n.c. 2 - Connection of ECG input and output side CH2: LED CH1: LED Rset + Electronic control gears | ZITARES CCD 2nd Generation Dimensions | weights | temperatures more ECGS – + – + – USB ohmic ohmic resistor resistor PE L A - Connection of ECG input and output side for DALI control Software ZITARES 360 N DA Programming Box DA DA PE L N DA DA n.c. DA DA DA n.c. more ECG BAG electronics | Product Catalogue 2014 73 ZITARES ICD Dimmable constant current ECG for LED modules (SELV) with programmable 2 channel output Electronic control gears | ZITARES ICD Product information • Dimmable 2 channel ECG for constant current operation of LED modules LED Components • Programmable functions* for modification according to specific applications - Individual output current in range 250-900 mA per channel - Dimming method: selection between Amplitude, PWM (500 Hz) and Mixed Mode - Compensation of LED degradation during operating time - Selection between 1 and 2 DALI addresses - Temperature-dependent control of output currents - Adjustment of output currents by means of resistors • Detect & React interface: analogue interface for connecting sensors e.g. for temperature or light detection • SELV equiv. output voltage ≤ 60 VDC Office & Commercial Outdoor Shop Technical data Conformity EN 61347-1 Mains voltage supply Rated voltage range 220 ... 240 [V] EN 61347-2-13 Rated frequency 0 / 50 ... 60 [Hz] EN 62384 Admissible continuous voltage range (AC) 198 - 264 [V] EN 61547 Admissible continuous voltage range (DC) 198 ... 278 [V] Max. leakage current 0.5 mA Total harmonic distortion (THD) 10 %, at 100 % load EN 55015 Switch-off of the LEDs at overvoltage appr. 320 VAC Overvoltage protection (time) 350 VAC / 2 h Output data adjustable • Soft start and low output current ripple Output current tolerance +/- 5 % • For use in luminaires of protection class I Max. ripple output current +/- 10% • ECG extensively protected against abnormal operating conditions at the output e.g. short-circuit, open circuit or overload Output voltage limitation 60 VDC; SELV equiv. Galvanic separation to mains input yes, test voltage 3.75 kV Max. starting time 0.5 s • Conformance with international regulations, regarding safety and operation, electromagnetic compatibility and immunity to interference • Nominal service life: 50,000 h with failure rate ≤ 10 % and operation at tc=tc,max * Programming via software ZITARES 360 Interfaces and dimming operation Sensor interface Dimming interfaces; depending on ECG model Product Catalogue 2014 | BAG electronics Detect & React Interface (DRI) DALI, Push-Dim Dimming range 1...100% Dimming technology PWM Max. number of ECGs (Push-Dim) 25 Degree of protection Degree of protection EN 62386-207 IEC 60068-2-6 Designations Constant current • Push-Dim function of DALI interface: switching and dimming via push-button EN 62386-102 IEC 60068-2-27 Behaviour at mains overvoltage • Very high efficiency of up to 90 % (100 % load) • Suitable for direct current operation and application in combination with central battery installations 74 Industry IP20 Operating data Designation Material number No. of channels ICD290-60LS-01/ 220-240/DALI 10105905 2 ICD290-100LS-01/ 220-240/DALI 10105906 2 Output current range (default) Output voltage Max. total output power Input current Power factor ECG efficiency mA VDC W A 250 ... 900 (700) 10 ... 33 60 0.30 0.98 90 250 ... 900 (700) 25 ... 53 96 0.45 0.98 90 Hole spacing XM (length direction) Hole spacing ZM (height direction) Weight Ambient temperature ta Housing temperature tc,max % - All specifications with 230 VAC nominal operation and 100 % load - Power output in undimmed operation should not go below 40 % of the maximum permissible value - Asymmetric load distribution on the outputs is permissible - Further output currents can be selected via parallel switching of the ECG outputs, see the table „Current selection“ Dimensions | weights | temperatures Short designation Length X Width Y Height Z mm mm mm mm mm kg °C °C ICD290-60LS-01... / DALI 360 30 21 350 9 0.315 -25 ... 50 75 ICD290-100LS-01... / DALI 360 30 21 350 9 0.315 -25 ... 50 75 ZM Z Output current ICD290-60LS··· 290-60LS··· ICD290-100LS··· 250 ... 900 mA 2x 2x 500 ... 1800 mA 1x 1 2 1 x 1 2 Y s. Wiring diagrams XM X Wiring diagrams 1 - Connection of ECG output side CH1: LED DRI PE L + N – + DA – + – DA sensor/ ohmic resistor Push-DIM LED Components CH2: LED B - Connection of ECG input side for control via push-button n.c. 2 - Connection of ECG input and output side CH2: LED CH1: LED DRI Electronic control gears | ZITARES ICD Current selection Case drawing + more ECG – C - Connection ECG-Programming Box for programming + – + – sensor/ ohmic ohmic resistor resistor A - Connection of ECG input and output side for DALI control USB PE L Software ZITARES 360 N DA Programming Box DA DA PE L N DA DA n.c. DA DA DA n.c. more ECG BAG electronics | Product Catalogue 2014 75 ZITARES CCS Non-dimmable constant current ECG for LED modules (SELV) with 4 channel output Electronic control gears | ZITARES CCS Product information • Non-dimmable 4-channel ECG for constant current operation of LED modules • Asymmetrical load for the output channels is admissible • Selection of additional output currents by means of parallel connection of the output channels • SELV equiv. output voltage ≤ 60 VDC LED Components • Very high efficiency of up to 93 % (100 % load) • Soft start and low output current ripple • For use in luminaires of protection class I • ECG extensively protected against abnormal operating conditions at the output e.g. short-circuit, open circuit or overload • Suitable for direct current operation and application in combination with central battery installations • Compact housing for maximum flexibility in luminaire design • Identical dimensions for dimmable and non-dimmable version • Certified as thermally protected device • Conformance with international regulations, regarding safety and operation, electromagnetic compatibility and immunity to interference • Nominal service life: 50,000 h with failure rate ≤ 10 % and operation at tc=tc,max Industry Office & Commercial Outdoor Shop Technical data Conformity EN 61347-1 Mains voltage supply Rated voltage range 220 ... 240 [V] EN 61347-2-13 Rated frequency 0 / 50 ... 60 [Hz] EN 62384 Admissible continuous voltage range (AC) 198 - 264 [V] EN 61547 Admissible continuous voltage range (DC) 198 ... 278 [V] Max. leakage current 0.5 mA Total harmonic distortion (THD) 10 %, at 100 % load EN 55015 Switch-off of the LEDs at overvoltage appr. 320 VAC Overvoltage protection (time) 350 VAC / 2 h Output data Designations Constant current fixed Output current tolerance +/- 5 % Max. ripple output current +/- 10% Output voltage limitation 60 VDC; SELV equiv. Galvanic separation to mains input yes, test voltage 3.75 kV Max. starting time 0.5 s Interfaces and dimming operation Dimming interfaces; depending on ECG model Degree of protection Product Catalogue 2014 | BAG electronics IEC 60068-2-27 Behaviour at mains overvoltage None Degree of protection 76 IEC 60068-2-6 IP20 Operating data Designation Material number No. of channels CCS435-70LS-01/220-240 10078975 4 CCS470-140LS-01/220-240 10078977 4 Output current Output voltage Max. total output power Input current Power factor ECG efficiency mA VDC W A 350 10 ... 50 70 0.36 0.98 92 700 10 ... 50 140 0.72 0.98 93 Hole spacing XM (length direction) Hole spacing ZM (height direction) Weight Ambient temperature ta Housing temperature tc,max % - All specifications with 230 VAC nominal operation and 100 % load - Power output in undimmed operation should not go below 20 % of the maximum permissible value - Asymmetric load distribution on the outputs is permissible - Further output currents can be selected via parallel switching of the ECG outputs, see the table „Current selection“ Dimensions | weights | temperatures Short designation Length X Width Y Height Z mm mm mm mm mm kg °C °C CCS4...70LS-01... 360 39 21 350 9 0.390 -25 ... 55 80 CCS4...140LS-01... 360 39 21 350 9 0.390 -25 ... 50 80 Current selection Output current CCS435-70LS··· 350 mA 4x 700 mA 2x 1x 2x 1.050 mA Y CCS470-140LS··· 1x 4x 1.400 mA XM 2.100 mA X 2.800 mA s. Wiring diagrams 2x 1x 1x 1x 1x 2x 1x 1x 1 2 3 4 5 1 2 3 4 5 Wiring diagrams 5 - Connection of ECG output side + – + CH2: LED – + CH3: LED – + CH4: LED – + – + CH2: LED – + CH3: LED – + CH4: LED – CH1: LED 2 - Connection of ECG output side CH1: LED LED LEDKomponenten Components 1 - Connection of ECG output side A - Connection of ECG input side PE L Electronic control gears | ZITARES CCS Z ZM Case drawing N + – + CH2: LED – + CH3: LED – + CH4: LED – CH1: LED 3 - Connection of ECG output side + – + CH2: LED – + CH3: LED – + CH4: LED – CH1: LED more ECG 4 - Connection of ECG output side + – + CH2: LED – + CH3: LED – + CH4: LED – CH1: LED BAG electronics | Product Catalogue 2014 77 ZITARES CCD Dimmable constant current ECG for LED modules (SELV) with 4 channel output Electronic control gears | ZITARES CCD Product information • Dimmable 4-channel ECG for constant current operation of LED modules • Asymmetrical load for the output channels is admissible • Selection of additional output currents by means of parallel connection of the output channels • SELV equiv. output voltage ≤ 60 VDC LED Components • Very high efficiency of up to 93 % (100 % load) • Soft start and low output current ripple • For use in luminaires of protection class I • ECG extensively protected against abnormal operating conditions at the output e.g. short-circuit, open circuit or overload • Suitable for direct current operation and application in combination with central battery installations • Overvoltage protection of the DALI and 1–10 V interfaces up to 264 VAC • Push-Dim function of DALI interface: switching and dimming via push-button • Settable recovery function: automatic switch-on after mains failure • Dimming range: 1 ... 100 % luminous flux • PWM dimming with 500 Hz for flicker-free light and prevention of stroboscopic effects • Compact housing for maximum flexibility in luminaire design • Identical dimensions for dimmable and non-dimmable versions • Certified as thermally protected device • Conformance with international regulations, regarding safety and operation, electromagnetic compatibility and immunity to interference • Nominal service life: 50,000 h with failure rate ≤ 10 % and operation at tc=tc,max 78 Product Catalogue 2014 | BAG electronics Industry Office & Commercial Outdoor Shop Technical data Conformity EN 61347-1 Mains voltage supply Rated voltage range 220 ... 240 [V] EN 61347-2-13 Rated frequency 0 / 50 ... 60 [Hz] EN 62384 Admissible continuous voltage range (AC) 198 - 264 [V] EN 61547 Admissible continuous voltage range (DC) 198 ... 278 [V] Max. leakage current 0.5 mA Total harmonic distortion (THD) 10 %, at 100 % load EN 55015 Switch-off of the LEDs at overvoltage appr. 320 VAC Overvoltage protection (time) 350 VAC / 2 h Output data fixed Output current tolerance +/- 5 % Max. ripple output current +/- 10% Output voltage limitation 60 VDC; SELV equiv. Galvanic separation to mains input yes, test voltage 3.75 kV Max. starting time 0.5 s Interfaces and dimming operation 1-10V, DALI, Push-Dim 1...100% Dimming technology PWM Max. Stand-by power (DALI & Push-Dim) 0.3 W Max. number of ECGs (Push-Dim) 25 Max. control current (1-10V) 0.6 mA Degree of protection Degree of protection IEC 60068-2-6 Designations Constant current Dimming range EN 62386-207 IEC 60068-2-27 Behaviour at mains overvoltage Dimming interfaces; depending on ECG model EN 62386-102 IP20 Operating data Designation Material number No. of channels Output current Output voltage Max. total output power Input current CCD435-70LS-01/ 220-240/1-10V 10079000 4 CCD435-70LS-01/ 220-240/DALI 10079001 CCD470-140LS-01/ 220-240/1-10V CCD470-140LS-01/ 220-240/DALI Power factor ECG efficiency mA VDC W A 350 10 ... 50 70 0.36 0.98 92 4 350 10 ... 50 70 0.36 0.98 92 10079004 4 700 10 ... 50 140 0.72 0.98 93 10079005 4 700 10 ... 50 140 0.72 0.98 93 Hole spacing XM (length direction) Hole spacing ZM (height direction) Weight Ambient temperature ta Housing temperature tc,max % - All specifications with 230 VAC nominal operation and 100 % load - Power output in undimmed operation should not go below 20 % of the maximum permissible value - Asymmetric load distribution on the outputs is permissible - Further output currents can be selected via parallel switching of the ECG outputs, see the table „Current selection“ Short designation Length X Width Y Height Z mm mm mm mm mm kg °C °C CCD4...70LS-01... / 1-10V 360 39 21 350 9 0.395 -25 ... 55 80 CCD4...70LS-01... / DALI 360 39 21 350 9 0.395 -25 ... 55 80 CCD4...140LS-01... / 1-10V 360 39 21 350 9 0.395 -25 ... 50 80 CCD4...140LS-01... / DALI 360 39 21 350 9 0.395 -25 ... 50 80 Case drawing Z ZM Current selection Output current CCD435-70LS··· 350 mA 4x 700 mA 2x 1x 2x 1.050 mA Y CCD470-140LS··· 1x 4x 1.400 mA XM 2.100 mA X 2.800 mA s. Wiring diagrams 2x 1x 1x 1x 1x 2x 1x 1x 1 2 3 4 5 1 2 3 4 5 1 - Connection of ECG output side + – + CH2: LED – + CH3: LED – + CH4: LED – CH1: LED 2 - Connection of ECG output side + – + CH2: LED – + CH3: LED – + CH4: LED – CH1: LED LED Components Wiring diagrams Electronic control gears | ZITARES CCD Dimensions | weights | temperatures 4 - Connection of ECG output side + – + CH2: LED – + CH3: LED – + CH4: LED – CH1: LED 5 - Connection of ECG output side + – + CH2: LED – + CH3: LED – + CH4: LED – CH1: LED 3 - Connection of ECG output side + – + CH2: LED – + CH3: LED – + CH4: LED – CH1: LED BAG electronics | Product Catalogue 2014 79 Wiring diagrams A - Connection of ECG input side for DALI control PE L N PE L – DA + DA – DA + n.c. n.c. more ECG B - Connection of ECG input side for control via push-button N DA DA n.c. Electronic control gears | ZITARES CCD more ECG LED Components 80 N DA more ECG PE L C - Connection of ECG input side for 1-10 V control Product Catalogue 2014 | BAG electronics Push-DIM 1-10 V 1-10 V BAG electronics | Product Catalogue 2014 81 LED Components Electronic control gears | ZITARES CCD ZITARES NCS Non-dimmable constant current ECG for LED modules (non-SELV) with single channel output Electronic control gears | ZITARES NCS Product information • Non-dimmable 1-channel ECG for constant current operation of LED modules • Non-SELV output voltage • Very high efficiency of up to 91 % (100 % load) • Soft start and low output current ripple • For use in luminaires of protection class I LED Components • ECG extensively protected against abnormal operating conditions at the output e.g. short-circuit, open circuit or overload • Suitable for direct current operation and application in combination with central battery installations • Conformance with international regulations, regarding safety and operation, electromagnetic compatibility and immunity to interference • Nominal service life: 50,000 h with failure rate ≤ 10 % and operation at tc=tc,max Industry Office & Commercial Outdoor Shop Technical data Conformity EN 61347-1 Mains voltage supply Rated voltage range 220 ... 240 [V] EN 61347-2-13 Rated frequency 0 / 50 ... 60 [Hz] EN 62384 Admissible continuous voltage range (AC) 198 - 264 [VAC] EN 61547 Admissible continuous voltage range DC 198 ... 278 [V] EN 55015 Max. leakage current 0.5 mA Total harmonic distortion (THD) 10 %, at 100 % load Behaviour at mains overvoltage Switch-off of the LEDs at overvoltage appr. 320 VAC Overvoltage protection (time) 350 V / 2 h Output data Designations Constant current fixed Output current tolerance +/- 5 % Max. ripple output current +/- 25 % Galvanic separation to mains input no Max. starting time 0.5 s Interfaces and dimming operation Dimming interfaces; depending on ECG model None Degree of protection Degree of protection 82 Product Catalogue 2014 | BAG electronics IEC 60068-2-27 IP00 Operating data Designation Material number No. of channels NCS170-60LP-01/220-240 10091635 1 Width Y Output current Output voltage Max. total output power Input current Power factor ECG efficiency mA VDC W A 700 33 ... 85 60 0.25 0.98 91 Height Z Hole spacing XM (length direction) Hole spacing YM (width direction) Weight Ambient temperature ta Housing temperature tc,max % - All specifications with 230 VAC nominal operation and 100 % load Dimensions | weights | temperatures Short designation Length X mm mm mm mm mm kg °C °C NCS170-60LP-01... 255 28 26 218 21.4 0.110 -25 ... 60 80 Case drawing Y YM XM Electronic control gears | ZITARES NCS X Wiring diagrams 1 - Connection of ECG output side + CH1 n.c. LED Components – BAG electronics | Product Catalogue 2014 83 ZITARES LCS Non-dimmable constant current ECG for LED modules (non-SELV) with single channel output Electronic control gears | ZITARES LCS Product information • Non-dimmable 1-channel ECG for constant current operation of LED modules • Non-SELV output voltage • Very high efficiency of up to 93 % (100 % load) • For use in luminaires of protection class I LED Components • ECG extensively protected against abnormal operating conditions at the output e.g. short-circuit, open circuit or overload • Compact housing for maximum flexibility in luminaire design • Certified as thermally protected device • Conformance with international regulations, regarding safety and operation, electromagnetic compatibility and immunity to interference • Nominal service life: 30,000 h with failure rate ≤ 10 % and operation at tc=tc,max Industry Office & Commercial Outdoor Shop Technical data Conformity EN 61347-1 Mains voltage supply Rated voltage range 220 ... 240 [V] EN 61347-2-13 Rated frequency 50 ... 60 [Hz] EN 62384 Admissible continuous voltage range (AC) 198 - 264 [VAC] EN 61547 Admissible continuous voltage range DC 198 ... 278 [V] EN 55015 Max. leakage current 0.5 mA Total harmonic distortion (THD) 15 %, at 100 % load Behaviour at mains overvoltage Switch-off of the LEDs at overvoltage appr. 320 VAC Overvoltage protection (time) 350 V / 2 h Output data Designations Constant current fixed Output current tolerance +/- 10 % Max. ripple output current +/- 20 % Galvanic separation to mains input no Max. starting time 0.5 s Interfaces and dimming operation Dimming interfaces; depending on ECG model None Degree of protection Degree of protection 84 Product Catalogue 2014 | BAG electronics IEC 60068-2-27 IP20 Operating data Designation Material number No. of channels Output current Output voltage Max. total output power Input current LCS135-70FX-01/220-240 10116496 1 LCS150-70FX-01/220-240 10116500 LCS170-70FX-01/220-240 10116504 Power factor ECG efficiency mA VDC W A 350 60 ... 200 70 0.31 0.98 93 1 500 60 ... 140 70 0.31 0.98 93 1 700 60 ... 100 70 0.31 0.98 93 Width Y Height Z Hole spacing XM (length direction) Hole spacing ZM (height direction) Weight Ambient temperature ta Housing temperature tc,max % - All specifications with 230 VAC nominal operation and 100 % load - Available as of Q3/2014 Dimensions | weights | temperatures Short designation Length X mm mm mm mm mm kg °C °C LCS135-70FX-01... 280 30 21 270 9 0.190 -25 ... 50 75 LCS150-70FX-01... 280 30 21 270 9 0.190 -25 ... 50 75 LCS170-70FX-01... 280 30 21 270 9 0.190 -25 ... 50 75 Y Electronic control gears | ZITARES LCS Z Zm Case drawing Xm X Wiring diagrams 1 1 - Connection of ECG output side + – LED Components CH1: LED A - Connection of ECG input side L N PE more ECG BAG electronics | Product Catalogue 2014 85 ZITARES NCS 2nd Generation Non-dimmable constant current ECG for LED modules (non-SELV) with adjustable single channel output Electronic control gears | ZITARES NCS 2nd Generation Product information • Non-dimmable 1-channel ECG for constant current operation of LED modules • Adjustable output currents by plug-in of resistors (LEDset) • Non-SELV output voltage • Very high efficiency of up to 94 % (100 % load) LED Components • Soft start and low output current ripple • For use in luminaires of protection class I • ECG extensively protected against abnormal operating conditions at the output e.g. short-circuit, open circuit or overload • Suitable for direct current operation and application in combination with central battery installations • Compact housing for maximum flexibility in luminaire design • Identical dimensions for dimmable and non-dimmable versions • Certified as thermally protected device • Conformance with international regulations, regarding safety and operation, electromagnetic compatibility and immunity to interference • Nominal service life: 50,000 h with failure rate ≤ 10 % and operation tc=tc,max Industry Office & Commercial Outdoor Shop Technical data Conformity EN 61347-1 Mains voltage supply Rated voltage range 220 ... 240 [V] EN 61347-2-13 Rated frequency 0 / 50 ... 60 [Hz] EN 62384 Admissible continuous voltage range (AC) 198 - 264 [VAC] EN 61547 Admissible continuous voltage range DC 198 ... 278 [V] Max. leakage current 0.5 mA Total harmonic distortion (THD) 10 %, at 100 % load EN 55015 Switch-off of the LEDs at overvoltage appr. 320 VAC Overvoltage protection (time) 350 V / 2 h Output data Designations Constant current adjustable Output current tolerance +/- 5 % Max. ripple output current +/- 10 % Galvanic separation to mains input no Max. starting time 0.5 s Interfaces and dimming operation Sensor interface Dimming interfaces; depending on ECG model Degree of protection Product Catalogue 2014 | BAG electronics IEC 60068-2-27 Behaviour at mains overvoltage LEDset None Degree of protection 86 IEC 60068-2-6 IP20 Operating data Designation Material number No. of channels Output current range (default) Output voltage Max. total output power Input current NCS135-70FX-20/220-240 10112200 1 NCS180-100FX-20/220-240 10112201 Power factor ECG efficiency mA VDC W A 120 ... 350 (350) 60 … 190 70 0.31 0.98 94 1 350 ... 800 (700) 30 ... 125 100 0.44 0.98 94 Width Y Height Z Hole spacing XM (length direction) Hole spacing ZM (height direction) Weight Ambient temperature ta Housing temperature tc,max % - All specifications with 230 VAC nominal operation and 100 % load - Available as of Q3/2014 Dimensions | weights | temperatures Short designation Length X mm mm mm mm mm kg °C °C NCS135-70FX-20... 280 30 21 270 9 0.200 -25 ... 60 75 NCS180-100FX-20... 280 30 21 270 9 0.250 -25 ... 60 75 Y Z Zm Electronic control gears | ZITARES NCS 2nd Generation Case drawing Xm X Wiring diagrams 1 - Connection of ECG output side LEDset + – ohmic ohmic resistor LED Components CH1: LED A - Connection of ECG input side L N PE more ECG BAG electronics | Product Catalogue 2014 87 ZITARES NCD 2nd Generation Dimmable constant current ECG for LED modules (non-SELV) with adjustable single channel output Electronic control gears | ZITARES NCD 2nd Generation Product information • Dimmable 1-channel ECG for constant current operation of LED modules • Adjustable output currents by plug-in of resistors or digital programming * • Non-SELV output voltage • Very high efficiency of up to 93 % (100 % load) LED Components • Soft start and low output current ripple • For use in luminaires of protection class I • ECG extensively protected against abnormal operating conditions at the output e.g. short-circuit, open circuit or overload • Suitable for direct current operation and application in combination with central battery installations Office & Commercial Outdoor Shop Technical data Conformity EN 61347-1 Mains voltage supply Rated voltage range 220 ... 240 [V] EN 61347-2-13 Rated frequency 0 / 50 ... 60 [Hz] EN 62384 Admissible continuous voltage range (AC) 198 - 264 [VAC] EN 61547 Max. leakage current 0.5 mA Total harmonic distortion (THD) 10 %, at 100 % load EN 55015 Behaviour at mains overvoltage Switch-off of the LEDs at overvoltage appr. 320 V Overvoltage protection (time) 350 V / 2 h Constant current adjustable Output current tolerance +/- 5 % • Push-Dim function of DALI interface: switching and dimming via push-button Max. ripple output current +/- 10% Galvanic separation to mains input no Max. starting time 0.5 s • Dimming range: 1 ... 100 % luminous flux • PWM dimming with 500 Hz for flicker-free light and prevention of stroboscopic effects • Compact housing for maximum flexibility in luminaire design • Identical dimensions for dimmable and non-dimmable versions • Certified as thermally protected device • Conformance with international regulations, regarding safety and operation, electromagnetic compatibility and immunity to interference • Nominal service life: 50,000 h with failure rate ≤ 10 % and operation at tc = tc,max * Programming via software ZITARES 360 Product Catalogue 2014 | BAG electronics IEC 60068-2-6 IEC 60068-2-27 EN 62386-102 EN 62386-207 Output data • Overvoltage protection of the DALI interface up to 264 VAC • Settable recovery function: automatic switch-on after mains failure 88 Industry Interfaces and dimming operation Sensor interface Dimming interfaces; depending on ECG model LEDset DALI, Push-Dim Dimming range 1...100% Dimming technology PWM Max. Stand-by power (DALI & Push-Dim) 0.3 W Max. number of ECGs (Push-Dim) 25 Degree of protection Degree of protection IP20 Designations Operating data Designation Material number No. of channels NCD135-70FX-20/ 220-240/DALI 10116488 1 NCD180-100FX-20/ 220-240/DALI 10116492 1 Output current range (default) Output voltage Max. total output power Input current Power factor ECG efficiency mA VDC W A 120 ... 350 (350) 60 … 190 70 0.31 0.98 93 350 ... 800 (700) 30 ... 125 100 0.44 0.98 93 % - All specifications with 230 VAC nominal operation and 100 % load - Power output in undimmed operation should not go below 20 % of the maximum permissible value - Available as of Q4/2014 Dimensions | weights | temperatures Length X Width Y Height Z Hole spacing XM (length direction) Hole spacing ZM (height direction) Weight Ambient temperature ta Housing temperature tc,max mm mm mm mm mm kg °C °C NCD135-70FX-20... / DALI 280 30 21 270 9 0.260 -25 ... 60 75 NCD180-70FX-20... / DALI 280 30 21 270 9 0.260 -25 ... 60 75 Electronic control gears | ZITARES NCD 2nd Generation Short designation Y Z Zm Case drawing Xm X Wiring diagrams C - Connection ECG-Programming Box for programming USB CH1: LED + L – LEDset ohmic ohmic resistor A - Connection of ECG input side for DALI control PE L Software ZITARES 360 N PE DA Programming Box DA LED Components 1 - Connection of ECG output side n.c. DA DA N DA DA n.c. DA DA more ECG B - Connection of ECG input side for control via push-button L N PE n.c. DA DA Push-DIM more ECG BAG electronics | Product Catalogue 2014 89 ZITARES OCS Non-dimmable constant current ECG for LED modules for outdoor applications Electronic control gears | ZITARES OCS Product information • 1-channel ECG for constant current operation of LED modules • Selectable output current via dip-switch • Very high efficiency of up to 93 % (100 % load) • Low ripple and tolerance of the output current for optimum LED operation LED Components • Certified as thermally protected device • High Surge immunity 6kV sym. and asym. • No additional surge protection component needed in the luminaire • LEDprotect protects the LED driver and the LED modules • Double insulated design - only basic insulation of LED modules in class II luminaires • Nominal service life: 80,000 h with failure rate ≤ 10 % and operation at tc = tc,max Industry Office & Commercial Outdoor Shop Technical data Conformity EN 61347-1 Mains voltage supply Rated voltage range 220 ... 240 [V] EN 61347-2-13 Rated frequency 50 / 60 Hz EN 62384 Admissible continuous voltage range (AC) 198 - 264 [V] EN 61547 Max. leakage current 0.5 mA Total harmonic distortion (THD) 10 %, at 100 % load EN 55015 Behaviour at mains overvoltage Switch-off of the LEDs at overvoltage appr. 320 VAC Overvoltage protection (time) 350 VAC / 48 h Output current tolerance +/- 5% Max. ripple output current +/- 10% Max. starting time 0.5 s Interfaces and dimming operation None Degree of protection Degree of protection Product Catalogue 2014 | BAG electronics IEC 60068-2-27 Output data Dimming interfaces; depending on ECG model 90 IEC 60068-2-6 IP40 Designations Operating data Designation 1 2 Material number No. of channels Output current Output voltage Max. total output power Input current Power factor ECG efficiency mA VDC W A OCS170-40LS-01/220-240 1 10111551 1 500/600/700 57 40 0.20 0.95 % 85 OCS170-80LS-01/220-240 2 10111552 1 500/600/700 114 80 0.40 0.95 90 OCS170-150LS-01/ 220-240 2 10111553 1 500/600/700 214 150 0.75 0.95 93 OCS1140-80LS-01/ 220-240 2 10116782 1 1050/1200/ 1400 60 80 0.40 0.95 90 OCS1140-150LS-01/ 220-240 2 10116783 1 1050/1200/ 1400 110 150 0.75 0.95 93 Available as of Q4/2014 Available as of Q3/2014 All specifications with 230 VAC nominal operation and 100 % load Short designation Length X Width Y Height Z Hole spacing XM (length direction) Weight Ambient temperature ta Housing temperature tc,max mm mm mm mm kg °C °C OCS170-40LS-01... 184 59 36 175 0.640 -30 ... 55 75 OCS170-80LS-01... 184 59 36 175 0.640 -30 ... 55 75 OCS170-150LS-01... 235 59 39 226 0.900 -30 ... 55 75 OCS1140-80LS-01... 184 59 36 175 0.640 -30 ... 55 75 OCS1140-150LS-01... 235 59 39 226 0.900 -30 ... 55 75 LED Components Y Z Case drawing Electronic control gears | ZITARES OCS Dimensions | weights | temperatures Xm X Wiring diagrams Wiring ECG output side with LEDprotect LEDprotect CH1 heatsink + – BAG electronics | Product Catalogue 2014 91 ZITARES OCD Dimmable constant current ECG for LED modules for outdoor applications Electronic control gears | ZITARES OCD Product information • Dimmable 1-channel ECG for constant current operation of LED modules • Programmable output current* • 3 dimming methods - geoDIM - independent adaptiv power reduction - DALI broadcast mode LED Components - control phase dimming • Very high efficiency of up to 93 % (100 % load) • Low ripple and tolerance of the output current for optimum LED operation • Certified as thermally protected device • High Surge immunity 6kV sym. and asym. • No additional surge protection component needed in the luminaire • LEDprotect protects the LED driver and the LED modules • Double insulated design - only basic unsulation of LED modules in class II luminaires • Nominal service life: 80,000 h with failure rate ≤ 10 % and operation at tc = tc,max * Programming via software ZITARES 360 92 Product Catalogue 2014 | BAG electronics Industry Office & Commercial Outdoor Shop Technical data Conformity EN 61347-1 Mains voltage supply Rated voltage range 220 ... 240 [V] EN 61347-2-13 Rated frequency 50 / 60 Hz EN 62384 Admissible continuous voltage range (AC) 198 - 264 [V] EN 55015 Max. leakage current 0.5 mA Total harmonic distortion (THD) 10 %, at 100 % load EN 61547 Behaviour at mains overvoltage Switch-off of the LEDs at overvoltage appr. 320 VAC Overvoltage protection (time) 350 VAC / 48 h EN 62386-102 IEC 60068-2-6 IEC 60068-2-27 Output data Output current tolerance +/- 5% Max. ripple output current +/- 10% Interfaces and dimming operation Dimming interfaces; depending on ECG model DALI, geoDIM, Control phase Dimming range 40...100% Dimming technology Amplitude Degree of protection Degree of protection IP40 Designations Operating data 1 2 Designation Material number No. of channels Output current range (default) Output voltage Max. total output power Input current OCD175-40LS-01/ 220-240/DALI 1 10111554 1 OCD175-80LS-01/ 220-240/DALI 2 10111555 OCD175-160LS-01/ 220-240/DALI 2 10111556 Power factor ECG efficiency mA VDC W A 350 ... 750 (700) 57 40 0.20 0.95 85 1 350 ... 750 (700) 114 80 0.40 0.95 90 1 350 ... 750 (700) 214 160 0.75 0.95 93 % Available as of Q4/2014 Available as of Q3/2014 All specifications with 230 VAC nominal operation and 100 % load Dimensions | weights | temperatures Short designation Length X Width Y Height Z Hole spacing XM (length direction) Weight Ambient temperature ta Housing temperature tc,max mm mm mm mm kg °C °C OCD175-40LS-01... / DALI 184 59 39 175 0.690 -30 ... 55 75 OCD175-80LS-01... / DALI 184 59 39 175 0.690 -30 ... 55 75 OCD175-160LS-01... / DALI 235 59 39 226 0.900 -30 ... 55 75 Y Z Electronic control gears | ZITARES OCD Case drawing Xm LED Components X Wiring diagrams Wiring ECG output by use of geoDIM LEDprotect heatsink LEDprotect CH1 Wiring ECG output side with LEDprotect by use of DALI use + CH1 – heatsink + – DA DA DA DA Wiring ECG output with LEDprotect by use of control phase dimming L more ECG N LEDprotect L N CH1 heatsink + – CP N more ECG BAG electronics | Product Catalogue 2014 93 ASTARES linear 2nd Generation LED modules in linear shape Product information LED Modules • Linear LED modules for use in linear and flat luminaires • Simple electrical connection via plug terminals with push buttons • Module mounting via screw fastening • Colour rendering CRI 84 for use in all standard applications LED Components • Very low tolerance in colour consistency with 3 SDCM • Very high efficiency of LED modules with up to 140 lm/W • LED modules suitable for operation in SELV and nonSELV applications Industry Office & Commercial Outdoor Shop Technical data Conformity EN 62031 Photometrical data Color consistency (initial SDCM) <3 EN 62471 Color consistency (after 50.000 h) < 4 EN 61547 Light distribution 120 ° (FWHM) Lambertian light distribution EN 55015 Tolerances of luminous flux ≤ 7.5 % Photo biological safety class 0 Electrical Data Operation Constant current • Matrix topology of LED arrangement for avoidance of dark zones with failure of individual LEDs Nominal operating current 700 mA Max. admissible operating current range 200 … 900 mA • In compliance with Zhaga specification Book 7 Max. admissible string voltage (for multiple connected modules) 300 VDC Min. creepage and clearance distances 4.0 mm Forward voltage 5% Assembly informationen Methode of fixing M4 screws Torque (pre-taped holes) 0.4 … 0.8 Nm Type of connector Push-In connector with release option MOLEX S-Poke 2P Operating temperature Max. case temperature (tc,max) +75 °C Max. performance temperature (tp,max) +65 °C Life time 94 Product Catalogue 2014 | BAG electronics Nominal life time 50,000 h Lumen maintenance (L-value) 80% (L80) Mortality (B-value) 50% (B50) Designations Operating data Designation Material number Typ. luminous flux Typ. colour temperature Typ. colour rendering Rated operation current Max. operating voltage Typ. power Typ. efficiency lm K CRI mA VDC W lm/W LMC-AS-110-830-LP-20/ L28W4 10107824 1050 3000 82 700 12 8 135 550 3000 82 350 12 4 135 LMC-AS-110-840-LP-20/ L28W4 10107825 1100 4000 84 700 12 8 140 550 4000 84 350 12 4 140 LMC-AS-200-830-LP-20/ L56W4 10107826 2100 3000 82 700 24 16 135 1050 3000 82 350 24 8 135 LMC-AS-200-840-LP-20/ L56W4 10107827 2200 4000 84 700 24 16 140 1100 4000 84 350 24 8 140 All operating data are refering to nominal operation at Tc = 65°C Dimensions Application notes In case of any handling of the modules precautions against mechanical stress and electrostatic discharge (ESD) have to be considered. 5 40 220 Ø 7 4, 11 System design have to fulfill all safety standards related to eletrical supply and installation conditions. 279,7 501 61 4, 7 40 5 Ø 11 57 281 560,7 LED Modules 82,9 Wiring diagrams – IN – + IN + OUT – OUT+ – IN – + IN + OUT – OUT+ IN – IN + LED Components ECG/EVG OUT – OUT+ ECG/EVG See accessories page 150 BAG electronics | Product Catalogue 2014 95 ASTARES plane 2nd Generation LED modules in planar shape Product information LED Modules • Flat LED modules for use in flat luminaires with diffuse covers Industry Office & Commercial Outdoor Shop Technical data Conformity EN 62031 Photometrical data LED Components Color consistency (initial SDCM) <3 EN 62471 Color consistency (after 50.000 h) <4 EN 61547 • High flexibility with installation in luminaires via conventional plug terminals for use of standard connection cables Light distribution 120 ° (FWHM) Lambertian light distribution EN 55015 • Optimised temperature distribution for simplified thermal management in the luminaire Tolerances of luminous flux ≤ 7.5 % Photo biological safety class 0 • Simple electrical interconnection of LED modules for assembly of systems • High value for colour rendering CRI 84 Electrical Data • Low colour tolerance of 3 SDCM Operation • Very high efficiency of LED modules with up to 145 lm/W Nominal operating current 700 mA Max. admissible operating current range 400 … 1400 mA Max. admissible string voltage (for multiple connected modules) 120 DC Min. creepage and clearance distances 2.5 mm Forward voltage 5% • Simple installation of modules in the luminaire via screw fastenings • Operation of LED modules optionally to dimmable or non-dimmable ECG with constant current • LED modules suitable for operation in SELV applications • Matrix topology of LED arrangement for avoidance of dark zones with failure of individual LEDs Constant current Assembly informationen Methode of fixing M4 screws, locking of open PCB ends in fixture Torque (pre-taped holes) 0.4 … 0.8 Nm Type of connector Push-In connector with release option MOLEX S-Poke 2P Operating temperature Max. case temperature (tc,max) +75 °C Max. performance temperature (tp,max) +65 °C Life time 96 Product Catalogue 2014 | BAG electronics Nominal life time 50,000 h Lumen maintenance (L-value) 80% (L80) Mortality (B-value) 50% (B50) Designations Operating data Designation Material number Typ. luminous flux Typ. colour temperature Typ. colour rendering Rated operation current Max. operating voltage Typ. power Typ. efficiency lm K CRI mA VDC W lm/W LMC-AS-120-840-PP-20 10112594 1250 4000 84 700 12 8 145 LMC-AS-120-830-PP-20 10112595 1200 3000 82 700 12 8 140 All operating data are refering to nominal operation at Tc = 65°C Application notes Dimensions 259 250 5,6 18 In case of any handling of the modules precautions against mechanical stress and electrostatic discharge (ESD) have to be considered. 18,5 14,5 250 199,75 System design have to fulfill all safety standards related to eletrical supply and installation conditions. 22 12 1,6 LED Modules Wiring diagrams – + LED Components ECG/EVG BAG electronics | Product Catalogue 2014 97 NEXARES 2nd generation All-In-One-systems Product information LED Modules • Flat LED light engine with integral LED module and electronic control gear in a single unit for use in luminaires with diffuse cover • Suitable for direct connection to mains voltage supply 220 - 240 V; 50 ... 60 Hz Industry Office & Commercial Outdoor Shop Technical data LED Components • Optimised temperature distribution for simplified thermal management in the luminaire • Low luminance tolerances via integrated current control on the PCB • High value for colour rendering CRI 84 • Low colour tolerance of 3 SDCM • High module efficiency of up to 135 lm/W • Simple installation of modules in the luminaire via screw fastenings • Space-saving installation in the luminaire because no additional control unit is needed EN 62031 Photometrical data Color consistency (initial SDCM) <3 EN 62471 Color consistency (after 50.000 h) <4 EN 61547 Light distribution 120 ° (FWHM) Lambertian light distribution EN 55015 • System power factor > 0.95 • Extremely flat design with a construction height of 8 mm with high uniformity of light distribution Conformity Tolerances of luminous flux ≤ 7.5 % Photo biological safety class 0 Operation Mains voltage supply Rated voltage range 220 ... 240 [V] Rated frequency 50 ... 60 [Hz] Min. creepage and clearance distances 4.0 Assembly informationen Methode of fixing M4 screws Torque (pre-taped holes) 0.4 … 0.8 Nm Type of connector Push-In connector with release option WAGO (Series 2060) Max. case temperature (tc,max) +75 °C Max. performance temperature (tp,max) +65 °C Life time Product Catalogue 2014 | BAG electronics EN 61347-2-13 Electrical Data Operating temperature 98 EN 61347-1 Nominal life time 50,000 h Lumen maintenance (L-value) 80% (L80) Mortality (B-value) 50% (B50) Designations Operating data Designation Material number Typ. luminous intensity Typ. colour temperature lm K LMM-NE-110-830-RP-02 10108580 1300 3000 Typ. colour rendering index Rated voltage range Rated frequency Rated operating Rated current power Typ. efficiency VAC HZ mA W lm/W 82 220 ... 240 50 ... 60 45 10.4 125 LMM-NE-110-840-RP-02 10108581 1300 4000 84 220 ... 240 50 ... 60 42 9.6 135 LMM-NE-200-830-RP-02 10108582 2000 3000 82 220 ... 240 50 ... 60 70 16 125 LMM-NE-200-840-RP-02 10108583 2000 4000 84 220 ... 240 50 ... 60 65 14.8 135 All operating data are refering to nominal operation at Tc = 65°C Dimensions Application notes 1,6 In case of any handling of the modules precautions against mechanical stress and electrostatic discharge (ESD) have to be considered. LED Components LED Modules 1,6 System design have to fulfill all safety standards related to eletrical supply and installation conditions. Wiring diagrams N L BAG electronics | Product Catalogue 2014 99 100 Product Catalogue 2014 | BAG electronics Komponentenforfürfluorescent Components Leuchtstofflampen lamps Elektronische Electronic control Vorschaltgeräte units for für T5-fluorescent T5 Leuchtstofflampen lamps MLS EVO MLD EVO DIM DALI BCS PRIMUS BCD 1-10 V T5 and und TC-L | Multi-Lamp-Technology Multi-Lamp-Technologie | linear .............. ...............102 112 T5 and und TC-L | Multi-Lamp-Technology Multi-Lamp-Technologie | linear .............. ...............106 116 T5 and und TC-L/F | linear ........................................................... ............................................................110 120 T5 | linear ..................................................................................124 ...................................................................................114 Electronic control units for T8 fluorescent lamps Elektronische BCS PRIMUS Vorschaltgeräte T8 | linear ..................................................................................128 für BCD 1-10 V T8 and TC-L/F | linear........................................................... 130 BCS PRIMUS BCD 1-10 V T8 | linear .................................................................................. 118 T8 und TC-L/F | linear .......................................................... 120 T8- Leuchtstofflampen fluorescent lamps BCS TC CFL, T5 and T8 | compact ......................................................134 BCS TCTWINGLE CFL, T5 and T8 | compact ......................................................136 BCS TCTWINGLE CFL, T5 and T8 | independent .............................................. 140 BCS TC Elektronische Vorschaltgeräte CFL, T5 and T8 | linear für ............................................................144 EBS MINIPOWER CFL, T5 and T8 | compact ......................................................148 BCD TC DALI Kompaktleuchtstofflampen CFL, T5 and T8 | Twingle-Technology |compact ................152 BCS TC 1-10 V BCD CFL, T5 and und T8 | Twingle-Technology kompakt ......................................................124 |compact ................154 BCS TCTWINGLE BCD CFL 1-10 V CFL, and CFL T5 und T5 |T8 compact | kompakt .............................................................156 ......................................................126 BCS TCTWINGLE CFL, T5 und T8 | unabhängig ............................................... 130 BCS TC CFL, T5 und T8 | linear ............................................................134 EBS MINIPOWER CFL, T5 und T8 | kompakt ......................................................138 BCD TC DALI CFL, T5 und T8 | Twingle-Technologie |kompakt ..............142 BCD TC 1-10 V CFL, T5 und T8 | Twingle-Technologie |kompakt ..............144 BCD CFL 1-10 V CFL und T5 | kompakt.............................................................146 BAG electronics | Product Catalogue 2014 Komponenten Components for für fluorescent Leuchtstofflampen lamps Electronic control units for compact 101 Productfinder - Selection table Power Number of Lamps Description Order No. [W] T5 102 Lenght X Width Y Height Z [mm] [mm] [mm] Interface Page 6 1 EBS16.1C-01/220-240 10050989 80 41 19 - 148 6 1 EBS16.1M-01/220-240 10050993 150 22 22 - 148 8 1 EBS16.1C-01/220-240 10050989 80 41 19 - 148 8 1 EBS16.1C-01/220-240 10050989 80 41 19 - 148 8 1 EBS16.1M-01/220-240 10050993 150 22 22 - 148 14 1 BCD35.1F-01/220-240/1-10V 10097244 360 30 21 1-10V 124 14 1 BCS21.1-2LS-01/220-240 10095043 150 42 30 - 112 14 1 BCS21.1-2Q-01/220-240 10097543 103 67 30 - 136 14 1 BCS21.1-2QI-01/220-240 10095743 180 86 33 - 140 14 1 BCS35.1FX-11/220-240 10077579 280 30 21 - 120 14 1 EBS21.1M-01/220-240 10050994 150 22 22 - 148 14 1 MLD39.1FR-11/220-240/DALI 10097811 360 30 21 DALI, Push-Dim 116 14 1 MLS39.1-2FR-11/220-240 10092026 280 30 21 - 112 14 2 BCD35.2F-01/220-240/1-10V 10097294 425 30 21 1-10V 124 14 2 BCS21.1-2LS-01/220-240 10095043 150 42 30 - 112 14 2 BCS21.1-2Q-01/220-240 10097543 103 67 30 - 136 14 2 BCS21.1-2QI-01/220-240 10095743 180 86 33 - 140 14 2 BCS35.2FX-11/220-240 10077580 280 30 21 - 120 14 2 MLD39.2FR-11/220-240/DALI 10092117 360 30 21 DALI, Push-Dim 116 14 2 MLS39.1-2FR-11/220-240 10092026 280 30 21 - 112 14 3 BCD14.3F-01/220-240/1-10V 10097281 360 39 21 1-10V 124 14 3 BCS14.3-4FR-01/220-240 10052868 280 42 21 - 120 14 3 MLD14/24.3FR-04/220-240/DALI 10105150 360 39 22 DALI, Push-Dim 116 14 3 MLS14/24.3-4.FR-11/220-240 10095345 280 39 21 - 112 14 4 BCD14.4F-01/220-240/1-10V 10097291 360 39 21 1-10V 124 14 4 BCS14.3-4FR-01/220-240 10052868 280 42 21 - 120 14 4 MLD14/24.4FR-04/220-240/DALI 10105151 360 39 22 DALI, Push-Dim 116 14 4 MLS14/24.3-4.FR-11/220-240 10095345 280 39 21 - 112 14 1 EBS16.1C-01/220-240 10050989 80 41 19 - 148 14 1 EBS16.1M-01/220-240 10050993 150 22 22 - 148 21 1 BCD35.1F-01/220-240/1-10V 10097244 360 30 21 1-10V 124 21 1 BCS21.1-2LS-01/220-240 10095043 150 42 30 - 112 21 1 BCS21.1-2Q-01/220-240 10097543 103 67 30 - 136 21 1 BCS21.1-2QI-01/220-240 10095743 180 86 33 - 140 21 1 BCS35.1FX-11/220-240 10077579 280 30 21 - 120 21 1 EBS21.1M-01/220-240 10050994 150 22 22 - 148 21 1 MLD39.1FR-11/220-240/DALI 10097811 360 30 21 DALI, Push-Dim 116 21 1 MLS39.1-2FR-11/220-240 10092026 280 30 21 - 112 21 2 BCD35.2F-01/220-240/1-10V 10097294 420 30 20 1-10V 124 21 2 BCS35.2FX-11/220-240 10077580 280 30 21 - 120 21 2 MLD39.2FR-11/220-240/DALI 10092117 360 30 21 DALI, Push-Dim 116 21 2 MLS39.1-2FR-11/220-240 10092026 280 30 21 - 112 24 1 BCD39.1F-01/220-240/1-10V 10097246 360 30 21 1-10V 124 24 1 BCD57.1/32.2Q-01/220-240/1-10V 10096387 103 67 30 1-10V 154 24 1 BCD57.1/32.2Q-01/220-240/DALI 10096397 103 67 30 DALI, Push-Dim 152 24 1 BCS39.1FX-11/220-240 10077581 280 30 21 - 120 24 1 BCS42.1/26.2LS-01/220-240 10095045 150 42 30 - 112 24 1 BCS42.1/26.2Q-01/220-240 10097545 103 67 30 - 136 24 1 BCS42.1/26.2QI-01/220-240 10095745 180 86 33 - 140 Product Catalogue 2014 | BAG electronics Productfinder - Selection table Power Number of Lamps Description Order No. [W] Lenght X Width Y Height Z [mm] [mm] [mm] Interface Page 24 1 BCS42.1Q-01/220-240 10097535 103 67 30 - 134 24 1 EBS26.1C-01/220-240 10050992 80 41 19 - 148 24 1 EBS26.1M-01/220-240 10050996 150 22 22 - 148 24 1 MLD39.1FR-11/220-240/DALI 10097811 360 30 21 DALI, Push-Dim 116 24 1 MLS39.1-2FR-11/220-240 10092026 280 30 21 - 112 24 2 BCD39.2F-01/220-240/1-10V 10097296 425 30 21 1-10V 124 24 2 BCD57.1/32.2Q-01/220-240/1-10V 10096387 103 67 30 1-10V 154 24 2 BCD57.1/32.2Q-01/220-240/DALI 10096397 103 67 30 DALI, Push-Dim 152 24 2 BCS39.2FX-11/220-240 10077582 280 30 21 - 120 24 2 BCS42.1/26.2LS-01/220-240 10095045 150 42 30 - 112 24 2 BCS42.1/26.2Q-01/220-240 10097545 103 67 30 - 136 24 2 BCS42.1/26.2QI-01/220-240 10095745 180 86 33 - 140 24 2 MLD39.2FR-11/220-240/DALI 10092117 360 30 21 DALI, Push-Dim 116 24 2 MLS39.1-2FR-11/220-240 10092026 280 30 21 - 112 24 3 BCD18.3-4F-01/220-240/1-10V 10097171 360 39 21 1-10V 130 24 3 MLD14/24.3FR-04/220-240/DALI 10105150 360 39 22 DALI, Push-Dim 116 24 3 MLS14/24.3-4.FR-11/220-240 10095345 280 39 21 - 112 24 4 MLD14/24.4FR-04/220-240/DALI 10105151 360 39 22 DALI, Push-Dim 116 24 4 MLS14/24.3-4.FR-11/220-240 10095345 280 39 21 - 112 28 1 BCD35.1F-01/220-240/1-10V 10097244 360 30 21 1-10V 124 28 1 BCS35.1FX-11/220-240 10077579 280 30 21 - 120 28 1 MLD54.1FR-11/220-240/DALI 10097815 360 30 21 DALI, Push-Dim 116 28 1 MLS80.1/54.2FR-11/220-240 10071609 280 30 21 - 112 28 1 MLS80.1FR-11/220-240 10071608 280 30 21 - 112 28 2 BCD35.2F-01/220-240/1-10V 10097294 420 30 20 1-10V 124 28 2 BCS35.2FX-11/220-240 10077580 280 30 21 - 120 28 2 MLD54.2FR-11/220-240/DALI 10092121 360 30 21 DALI, Push-Dim 116 28 2 MLS80.1/54.2FR-11/220-240 10071609 280 30 21 - 112 35 1 BCD35.1F-01/220-240/1-10V 10097244 360 30 21 1-10V 124 35 1 BCS35.1FX-11/220-240 10077579 280 30 21 - 120 35 1 MLD54.1FR-11/220-240/DALI 10097815 360 30 21 DALI, Push-Dim 116 35 1 MLD80.1FR-11/220-240/DALI 10097820 360 30 21 DALI, Push-Dim 116 35 1 MLS80.1/54.2FR-11/220-240 10071609 280 30 21 - 112 35 1 MLS80.1FR-11/220-240 10071608 280 30 21 - 112 35 2 BCD35.2F-01/220-240/1-10V 10097294 420 30 20 1-10V 124 35 2 BCS35.2FX-11/220-240 10077580 280 30 21 - 120 35 2 MLD54.2FR-11/220-240/DALI 10092121 360 30 21 DALI, Push-Dim 116 35 2 MLD80.2FR-11/220-240/DALI 10101905 425 30 21 DALI, Push-Dim 116 35 2 MLS80.1/54.2FR-11/220-240 10071609 280 30 21 - 112 39 1 BCD39.1F-01/220-240/1-10V 10097246 360 30 21 1-10V 124 39 1 BCD57.1/32.2Q-01/220-240/1-10V 10096387 103 67 30 1-10V 154 39 1 BCD57.1/32.2Q-01/220-240/DALI 10096397 103 67 30 DALI, Push-Dim 152 39 1 BCS39.1FX-11/220-240 10077581 280 30 21 - 120 39 1 BCS42.1/26.2LS-01/220-240 10095045 150 42 30 - 112 39 1 BCS42.1/26.2Q-01/220-240 10097545 103 67 30 - 136 39 1 BCS42.1/26.2QI-01/220-240 10095745 180 86 33 - 140 39 1 BCS42.1Q-01/220-240 10097535 103 67 30 - 134 39 1 MLD39.1FR-11/220-240/DALI 10097811 360 30 21 DALI, Push-Dim 116 39 1 MLS39.1-2FR-11/220-240 10092026 280 30 21 - 112 T5 BAG electronics | Product Catalogue 2014 103 Productfinder - Selection table Power Number of Lamps Description Order No. [W] T5 104 Lenght X Width Y Height Z [mm] [mm] [mm] Interface Page 39 2 BCD39.2F-01/220-240/1-10V 10097296 425 30 21 1-10V 124 39 2 BCS39.2FX-11/220-240 10077582 280 30 21 - 120 39 2 MLD39.2FR-11/220-240/DALI 10092117 360 30 21 DALI, Push-Dim 116 39 2 MLS39.1-2FR-11/220-240 10092026 280 30 21 - 112 49 1 BCD49.1F-01/220-240/1-10V 10097247 360 30 21 1-10V 124 49 1 BCS49.1FX-11/220-240 10077583 280 30 21 - 120 49 1 MLD54.1FR-11/220-240/DALI 10097815 360 30 21 DALI, Push-Dim 116 49 1 MLD80.1FR-11/220-240/DALI 10097820 360 30 21 DALI, Push-Dim 116 49 1 MLS80.1/54.2FR-11/220-240 10071609 280 30 21 - 112 49 1 MLS80.1FR-11/220-240 10071608 280 30 21 - 112 49 2 BCD49.2F-01/220-240/1-10V 10097297 425 30 21 1-10V 124 49 2 BCS49.2FX-11/220-240 10077584 280 30 21 - 120 49 2 MLD54.2FR-11/220-240/DALI 10092121 360 30 21 DALI, Push-Dim 116 49 2 MLD80.2FR-11/220-240/DALI 10101905 425 30 21 DALI, Push-Dim 116 49 2 MLS80.1/54.2FR-11/220-240 10071609 280 30 21 - 112 54 1 BCD54.1F-01/220-240/1-10V 10097248 360 30 21 1-10V 124 54 1 BCS54.1FX-11/220-240 10077585 280 30 21 - 120 54 1 MLD54.1FR-11/220-240/DALI 10097815 360 30 21 DALI, Push-Dim 116 54 1 MLS80.1/54.2FR-11/220-240 10071609 280 30 21 - 112 54 1 MLS80.1FR-11/220-240 10071608 280 30 21 - 112 54 2 BCD54.2F-01/220-240/1-10V 10097298 425 30 21 1-10V 124 54 2 BCS54.2FX-11/220-240 10077586 280 30 21 - 120 54 2 MLD54.2FR-11/220-240/DALI 10092121 360 30 21 DALI, Push-Dim 116 54 2 MLS80.1/54.2FR-11/220-240 10071609 280 30 21 - 112 80 1 BCD80.1F-01/220-240/1-10V 10097249 360 30 21 1-10V 124 80 1 BCS80.1FX-11/220-240 10077587 280 30 21 - 120 80 1 MLD80.1FR-11/220-240/DALI 10097820 360 30 21 DALI, Push-Dim 116 80 1 MLS80.1/54.2FR-11/220-240 10071609 280 30 21 - 112 80 1 MLS80.1FR-11/220-240 10071608 280 30 21 - 112 80 2 BCD80.2F-01/220-240/1-10V 10097299 425 30 21 1-10V 124 80 2 MLD80.2FR-11/220-240/DALI 10101905 425 30 21 DALI, Push-Dim 116 Product Catalogue 2014 | BAG electronics Productfinder - Selection table Power Number of Lamps Description Order No. [W] Lenght X Width Y Height Z Interface Page 154 [mm] [mm] [mm] 22 1 BCD57.1/32.2Q-01/220-240/1-10V 10096387 103 67 30 1-10V 22 1 BCD57.1/32.2Q-01/220-240/DALI 10096397 103 67 30 DALI, Push-Dim 152 22 1 BCS42.1/26.2LS-01/220-240 10095045 150 42 30 - 112 22 1 BCS42.1/26.2Q-01/220-240 10097545 103 67 30 - 136 22 1 BCS42.1/26.2QI-01/220-240 10095745 180 86 33 - 140 22 1 BCS42.1Q-01/220-240 10097535 103 67 30 - 134 22 1 EBS26.1C-01/220-240 10050992 80 41 19 - 148 22 1 EBS26.1M-01/220-240 10050996 150 22 22 - 148 22 2 BCD57.1/32.2Q-01/220-240/1-10V 10096387 103 67 30 1-10V 154 22 2 BCD57.1/32.2Q-01/220-240/DALI 10096397 103 67 30 DALI, Push-Dim 152 22 2 BCS42.1/26.2LS-01/220-240 10095045 150 42 30 - 112 22 2 BCS42.1/26.2Q-01/220-240 10097545 103 67 30 - 136 22 2 BCS42.1/26.2QI-01/220-240 10095745 180 86 33 - 140 22 2 BCS70.1/42.2Q-01/220-240 10097546 103 67 30 - 136 40 1 BCD57.1/32.2Q-01/220-240/1-10V 10096387 103 67 30 1-10V 154 40 1 BCD57.1/32.2Q-01/220-240/DALI 10096397 103 67 30 DALI, Push-Dim 152 40 1 BCS42.1/26.2LS-01/220-240 10095045 150 42 30 - 112 40 1 BCS42.1/26.2Q-01/220-240 10097545 103 67 30 - 136 40 1 BCS42.1/26.2QI-01/220-240 10095745 180 86 33 - 140 40 1 BCS42.1Q-01/220-240 10097535 103 67 30 - 134 55 1 BCD55.1Q-01/220-240/1-10V 10096388 103 67 30 - 156 55 1 BCS55.1Q-01/220-240/T5C 10097634 103 67 30 - 134 60 1 BCD60.1Q-01/220-240/1-10V 10096389 103 67 30 - 156 60 1 BCS60.1Q-01/220-240 10097635 103 67 30 - 134 T5C T5 BAG electronics | Product Catalogue 2014 105 Productfinder - Selection table Power Lamp Number Description of Lamps Order No. [W] T8 T5 106 Lenght X Width Y Height Z Interface Page [mm] [mm] [mm] 15 1 T8 BCD57.1/32.2Q-01/220-240/1-10V 10096387 103 67 30 1-10V 154 15 1 T8 BCD57.1/32.2Q-01/220-240/DALI 10096397 103 67 30 DALI, Push-Dim 152 15 1 T8 BCS42.1/26.2LS-01/220-240 10095045 150 42 30 - 112 15 1 T8 BCS42.1/26.2Q-01/220-240 10097545 103 67 30 - 136 15 1 T8 BCS42.1/26.2QI-01/220-240 10095745 180 86 33 - 140 15 1 T8 BCS42.1Q-01/220-240 10097535 103 67 30 - 134 15 1 T8 EBS26.1C-01/220-240 10050992 80 41 19 - 148 15 2 T8 BCD57.1/32.2Q-01/220-240/1-10V 10096387 103 67 30 1-10V 154 15 2 T8 BCD57.1/32.2Q-01/220-240/DALI 10096397 103 67 30 DALI, Push-Dim 152 15 2 T8 BCS42.1/26.2LS-01/220-240 10095045 150 42 30 - 112 15 2 T8 BCS42.1/26.2Q-01/220-240 10097545 103 67 30 - 136 15 2 T8 BCS42.1/26.2QI-01/220-240 10095745 180 86 33 - 140 18 1 T8 BCD18.1F-01/220-240/1-10V 10097143 360 30 21 1-10V 130 18 1 T8 BCD57.1/32.2Q-01/220-240/1-10V 10096387 103 67 30 1-10V 154 18 1 T8 BCD57.1/32.2Q-01/220-240/DALI 10096397 103 67 30 DALI, Push-Dim 152 18 1 T8 BCS18.1FX-11/220-240 10077588 280 30 21 - 128 18 1 T8 BCS39.1FX-11/220-240 10077581 280 30 21 - 120 18 1 T8 BCS42.1/26.2LS-01/220-240 10095045 150 42 30 - 112 18 1 T8 BCS42.1/26.2Q-01/220-240 10097545 103 67 30 - 136 18 1 T8 BCS42.1/26.2QI-01/220-240 10095745 180 86 33 - 140 18 1 T8 BCS42.1Q-01/220-240 10097535 103 67 30 - 134 18 1 T8 EBS16.1C-01/220-240 10050989 80 41 19 - 148 18 1 T8 EBS16.1M-01/220-240 10050993 150 22 22 - 148 18 1 T8 EBS26.1C-01/220-240 10050992 80 41 19 - 148 18 1 T8 EBS26.1M-01/220-240 10050996 150 22 22 - 148 18 2 T8 BCD18.2F-01/220-240/1-10V 10097193 425 30 21 1-10V 130 18 2 T8 BCD57.1/32.2Q-01/220-240/1-10V 10096387 103 67 30 1-10V 154 18 2 T8 BCD57.1/32.2Q-01/220-240/DALI 10096397 103 67 30 DALI, Push-Dim 152 18 2 T8 BCS18.2FX-11/220-240 10077589 280 30 21 - 128 18 2 T8 BCS42.1/26.2LS-01/220-240 10095045 150 42 30 - 112 18 2 T8 BCS42.1/26.2Q-01/220-240 10097545 103 67 30 - 136 18 2 T8 BCS42.1/26.2QI-01/220-240 10095745 180 86 33 - 140 18 3 T8 BCD18.3-4F-01/220-240/1-10V 10097171 360 39 21 1-10V 130 18 3 T8 BCS18.3-4LR-01/220-240 10050999 290 42 28 - 128 18 3 T8 MLD14/24.3FR-04/220-240/DALI 10105150 360 39 22 DALI, Push-Dim 116 18 4 T8 BCD18.3-4F-01/220-240/1-10V 10097171 360 39 21 1-10V 130 18 4 T8 BCS18.3-4LR-01/220-240 10050999 290 42 28 - 128 18 4 T8 MLD14/24.4FR-04/220-240/DALI 10105151 360 39 22 DALI, Push-Dim 116 30 1 T8 BCD18.1F-01/220-240/1-10V 10097143 360 30 21 1-10V 130 30 1 T8 BCS28.1LS-01/220-240 10097426 150 42 30 - 112 30 2 T8 BCD18.2F-01/220-240/1-10V 10097193 425 30 21 1-10V 130 36 1 T8 BCD36.1F-01/220-240/1-10V 10097144 360 30 21 1-10V 130 36 1 T8 BCD57.1/32.2Q-01/220-240/1-10V 10096387 103 67 30 1-10V 154 36 1 T8 BCD57.1/32.2Q-01/220-240/DALI 10096397 103 67 30 DALI, Push-Dim 152 36 1 T8 BCS36.1FX-11/220-240 10077590 280 30 21 - 128 36 1 T8 BCS38.1LS-01/220-240 10097427 150 42 30 - 112 36 1 T8 BCS39.1FX-11/220-240 10077581 280 30 21 - 120 36 1 T8 BCS42.1/26.2LS-01/220-240 10095045 150 42 30 - 112 36 1 T8 BCS42.1/26.2Q-01/220-240 10097545 103 67 30 - 136 36 1 T8 BCS42.1/26.2QI-01/220-240 10095745 180 86 33 - 140 36 1 T8 BCS42.1Q-01/220-240 10097535 103 67 30 - 134 36 2 T8 BCD36.2F-01/220-240/1-10V 10097194 425 30 21 1-10V 130 36 2 T8 BCD57.1/32.2Q-01/220-240/1-10V 10096387 103 67 30 1-10V 154 36 2 T8 BCD57.1/32.2Q-01/220-240/DALI 10096397 103 67 30 DALI, Push-Dim 152 36 2 T8 BCS36.2FX-11/220-240 10077591 280 30 21 - 128 36 3 T8 MLS14/24.3-4.FR-11/220-240 10095345 280 39 21 - 112 58 1 T8 BCD58.1F-01/220-240/1-10V 10097145 360 30 21 1-10V 130 58 1 T8 BCS54.1FX-11/220-240 10077585 280 30 21 - 120 58 1 T8 BCS58.1FX-11/220-240 10077592 280 30 21 - 128 Product Catalogue 2014 | BAG electronics Productfinder - Selection table Power Lamp Number Description of Lamps Order No. [W] Lenght X Width Y Height Z [mm] Interface Page [mm] [mm] 58 2 T8 BCD58.2F-01/220-240/1-10V 10097195 425 30 21 1-10V 130 58 2 T8 BCS58.2FX-11/220-240 10077593 280 30 21 - 128 10 1 TC-DD BCS21.1-2LS-01/220-240 10095043 150 42 30 - 112 10 1 TC-DD BCS21.1-2Q-01/220-240 10097543 103 67 30 - 136 10 1 TC-DD BCS21.1-2QI-01/220-240 10095743 180 86 33 - 140 10 1 TC-DD EBS16.1C-01/220-240 10050989 80 41 19 - 148 10 2 TC-DD BCS21.1-2LS-01/220-240 10095043 150 42 30 - 112 10 2 TC-DD BCS21.1-2Q-01/220-240 10097543 103 67 30 - 136 10 2 TC-DD BCS21.1-2QI-01/220-240 10095743 180 86 33 - 140 16 1 TC-DD BCS21.1-2LS-01/220-240 10095043 150 42 30 - 112 16 1 TC-DD BCS21.1-2Q-01/220-240 10097543 103 67 30 - 136 16 1 TC-DD BCS21.1-2QI-01/220-240 10095743 180 86 33 - 140 16 1 TC-DD EBS16.1C-01/220-240 10050989 80 41 19 - 148 16 1 TC-DD EBS16.1M-01/220-240 10050993 150 22 22 - 148 16 2 TC-DD BCS21.1-2LS-01/220-240 10095043 150 42 30 - 112 16 2 TC-DD BCS21.1-2Q-01/220-240 10097543 103 67 30 - 136 16 2 TC-DD BCS21.1-2QI-01/220-240 10095743 180 86 33 - 140 28 1 TC-DD BCS28.1LS-01/220-240 10097426 150 42 30 - 112 28 1 TC-DD BCS28.1Q-01/220-240 10097436 103 67 30 - 134 38 1 TC-DD BCS38.1LS-01/220-240 10097427 150 42 30 - 112 38 1 TC-DD BCS38.1Q-01/220-240 10097437 103 67 30 - 134 55 1 TC-DD BCS55.1Q-01/220-240/TC-DD 10097439 103 67 30 - 134 T8 TC-DD T5 BAG electronics | Product Catalogue 2014 107 Productfinder - Selection table Power Lamp Number Description of Lamps Order No. [W] TC-DEL TC-TEL TC-SEL T5 108 Lenght X Width Y Height Z Interface Page [mm] [mm] [mm] 7 TC-SEL 1 EBS16.1C-01/220-240 10050989 80 41 19 - 148 7 TC-SEL 1 EBS16.1M-01/220-240 10050993 150 22 22 - 148 9 TC-SEL 1 BCS21.1-2LS-01/220-240 10095043 150 42 30 - 112 9 TC-SEL 1 BCS21.1-2QI-01/220-240 10095743 180 86 33 - 140 9 TC-SEL 1 EBS16.1C-01/220-240 10050989 80 41 19 - 148 9 TC-SEL 1 EBS16.1M-01/220-240 10050993 150 22 22 - 148 9 TC-SEL 2 BCS21.1-2LS-01/220-240 10095043 150 42 30 - 112 9 TC-SEL 2 BCS21.1-2Q-01/220-240 10097543 103 67 30 - 136 9 TC-SEL 2 BCS21.1-2QI-01/220-240 10095743 180 86 33 - 140 9 TC-SEL 1 BCS21.1-2Q-01/220-240 10097543 103 67 30 - 136 10 TC-DEL 1 BCS21.1-2LS-01/220-240 10095043 150 42 30 - 112 10 TC-DEL 1 BCS21.1-2Q-01/220-240 10097543 103 67 30 - 136 10 TC-DEL 1 BCS21.1-2QI-01/220-240 10095743 180 86 33 - 140 10 TC-DEL 1 EBS16.1C-01/220-240 10050989 80 41 19 - 148 10 TC-DEL 1 EBS16.1M-01/220-240 10050993 150 22 22 - 148 10 TC-DEL 2 BCS21.1-2LS-01/220-240 10095043 150 42 30 - 112 10 TC-DEL 2 BCS21.1-2Q-01/220-240 10097543 103 67 30 - 136 10 TC-DEL 2 BCS21.1-2QI-01/220-240 10095743 180 86 33 - 140 11 TC-SEL 1 BCS21.1-2LS-01/220-240 10095043 150 42 30 - 112 11 TC-SEL 1 BCS21.1-2Q-01/220-240 10097543 103 67 30 - 136 11 TC-SEL 1 BCS21.1-2QI-01/220-240 10095743 180 86 33 - 140 11 TC-SEL 1 EBS16.1C-01/220-240 10050989 80 41 19 - 148 11 TC-SEL 1 EBS16.1M-01/220-240 10050993 150 22 22 - 148 11 TC-SEL 2 BCS21.1-2LS-01/220-240 10095043 150 42 30 - 112 11 TC-SEL 2 BCS21.1-2Q-01/220-240 10097543 103 67 30 - 136 11 TC-SEL 2 BCS21.1-2QI-01/220-240 10095743 180 86 33 - 140 13 TC-DEL 1 BCD13.1-2Q-01/220-240/1-10V 10096393 103 67 30 1-10V 154 13 TC-DEL 1 BCS21.1-2LS-01/220-240 10095043 150 42 30 - 112 13 TC-DEL 1 BCS21.1-2Q-01/220-240 10097543 103 67 30 - 136 13 TC-DEL 1 BCS21.1-2QI-01/220-240 10095743 180 86 33 - 140 13 TC-DEL 1 EBS21.1C-01/220-240 10050990 80 41 19 - 148 13 TC-DEL 1 EBS21.1M-01/220-240 10050994 150 22 22 - 148 13 TC-TEL 2 BCD13.1-2Q-01/220-240/1-10V 10096393 103 67 30 1-10V 154 13 TC-TEL 2 BCS21.1-2LS-01/220-240 10095043 150 42 30 - 112 13 TC-TEL 2 BCS21.1-2Q-01/220-240 10097543 103 67 30 - 136 13 TC-TEL 2 BCS21.1-2QI-01/220-240 10095743 180 86 33 - 140 18 TC-DEL 1 BCD18.1-2Q-01/220-240/1-10V 10096385 103 67 30 1-10V 154 18 TC-DEL 1 BCD18.1-2Q-01/220-240/DALI 10096395 103 67 30 DALI, Push-Dim 152 18 TC-DEL 1 BCS18.1-2LS-01/220-240 10095044 150 42 30 - 112 18 TC-DEL 1 BCS18.1-2Q-01/220-240 10097544 103 67 30 - 136 18 TC-DEL 1 BCS18.1-2QI-01/220-240 10095744 180 86 33 - 140 18 TC-DEL 1 BCS18.1Q-01/220-240 10097534 103 67 30 - 134 18 TC-DEL 1 EBS21.1C-01/220-240 10050990 80 41 19 - 148 18 TC-DEL 1 EBS21.1M-01/220-240 10050994 150 22 22 - 148 18 TC-DEL 2 BCS18.1-2LS-01/220-240 10095044 150 42 30 - 112 18 TC-DEL 2 BCS18.1-2Q-01/220-240 10097544 103 67 30 - 136 18 TC-DEL 2 BCS18.1-2QI-01/220-240 10095744 180 86 33 - 140 18 TC-TEL 2 BCD18.1-2Q-01/220-240/1-10V 10096385 103 67 30 1-10V 154 18 TC-TEL 2 BCD18.1-2Q-01/220-240/DALI 10096395 103 67 30 DALI, Push-Dim 152 26 TC-DEL 1 BCS42.1/26.2LS-01/220-240 10095045 150 42 30 - 112 26 TC-DEL 1 BCS42.1/26.2Q-01/220-240 10097545 103 67 30 - 136 26 TC-DEL 1 BCS42.1/26.2QI-01/220-240 10095745 180 86 33 - 140 26 TC-DEL 1 BCS42.1Q-01/220-240 10097535 103 67 30 - 134 26 TC-DEL 1 BCS70.1/42.2Q-01/220-240 10097546 103 67 30 - 136 26 TC-DEL 1 EBS26.1C-01/220-240 10050992 80 41 19 - 148 26 TC-DEL 1 EBS26.1M-01/220-240 10050996 150 22 22 - 148 26 TC-DEL 1 SCS42.1Q-01/220-240/4kV 166772 103 67 31 - 134 26 TC-DEL 2 BCS42.1/26.2LS-01/220-240 10095045 150 42 30 - 112 Product Catalogue 2014 | BAG electronics Productfinder - Selection table Power Lamp Number Description of Lamps Order No. [W] Lenght X Width Y Height Z Interface Page [mm] [mm] [mm] 26 TC-DEL 2 BCS42.1/26.2Q-01/220-240 10097545 103 67 30 - 136 26 TC-DEL 2 BCS42.1/26.2QI-01/220-240 10095745 180 86 33 - 140 26 TC-DEL 2 BCS70.1/42.2Q-01/220-240 10097546 103 67 30 - 136 26 TC-TEL 1 BCD57.1/32.2Q-01/220-240/1-10V 10096387 103 67 30 1-10V 154 26 TC-TEL 1 BCD57.1/32.2Q-01/220-240/DALI 10096397 103 67 30 DALI, Push-Dim 152 26 TC-TEL 2 BCD42.2Q-01/220-240/1-10V 10097580 123 102 33 - 156 154 26 TC-TEL 2 BCD57.1/32.2Q-01/220-240/1-10V 10096387 103 67 30 1-10V 26 TC-TEL 2 BCD57.1/32.2Q-01/220-240/DALI 10096397 103 67 30 DALI, Push-Dim 152 32 TC-TEL 1 BCD57.1/32.2Q-01/220-240/1-10V 10096387 103 67 30 1-10V 154 32 TC-TEL 1 BCD57.1/32.2Q-01/220-240/DALI 10096397 103 67 30 DALI, Push-Dim 152 32 TC-TEL 1 BCS42.1/26.2LS-01/220-240 10095045 150 42 30 - 112 32 TC-TEL 1 BCS42.1/26.2Q-01/220-240 10097545 103 67 30 - 136 32 TC-TEL 1 BCS42.1/26.2QI-01/220-240 10095745 180 86 33 - 140 32 TC-TEL 1 BCS42.1Q-01/220-240 10097535 103 67 30 - 134 32 TC-TEL 1 BCS70.1/42.2Q-01/220-240 10097546 103 67 30 - 136 32 TC-TEL 1 SCS42.1Q-01/220-240/4kV 166772 103 67 30 - 134 32 TC-TEL 2 BCD42.2Q-01/220-240/1-10V 10097580 123 102 33 - 156 32 TC-TEL 2 BCD57.1/32.2Q-01/220-240/1-10V 10096387 103 67 30 1-10V 154 32 TC-TEL 2 BCD57.1/32.2Q-01/220-240/DALI 10096397 103 67 30 DALI, Push-Dim 152 32 TC-TEL 2 BCS70.1/42.2Q-01/220-240 10097546 103 67 30 - 136 154 42 TC-TEL 1 BCD57.1/32.2Q-01/220-240/1-10V 10096387 103 67 30 1-10V 42 TC-TEL 1 BCD57.1/32.2Q-01/220-240/DALI 10096397 103 67 30 DALI, Push-Dim 152 42 TC-TEL 1 BCS42.1/26.2LS-01/220-240 10095045 150 42 30 - 112 42 TC-TEL 1 BCS42.1/26.2Q-01/220-240 10097545 103 67 30 - 136 42 TC-TEL 1 BCS42.1/26.2QI-01/220-240 10095745 180 86 33 - 140 42 TC-TEL 1 BCS42.1Q-01/220-240 10097535 103 67 30 - 134 42 TC-TEL 1 BCS70.1/42.2Q-01/220-240 10097546 103 67 30 - 136 42 TC-TEL 1 SCS42.1Q-01/220-240/4kV 166772 103 67 30 - 134 42 TC-TEL 2 BCD42.2Q-01/220-240/1-10V 10097580 123 102 33 - 156 42 TC-TEL 2 BCS70.1/42.2Q-01/220-240 10097546 103 67 30 - 136 57 TC-TEL 1 BCD57.1/32.2Q-01/220-240/1-10V 10096387 103 67 30 1-10V 154 57 TC-TEL 1 BCD57.1/32.2Q-01/220-240/DALI 10096397 103 67 30 DALI, Push-Dim 152 57 TC-TEL 1 BCS70.1/42.2Q-01/220-240 10097546 103 67 30 - 136 70 TC-TEL 1 BCS70.1/42.2Q-01/220-240 10097546 103 67 30 - 136 TC-DEL TC-TEL TC-SEL T5 BAG electronics | Product Catalogue 2014 109 Productfinder - Selection table Power Lamp Number Description of Lamps Order No. [W] TC-L/F 110 Lenght X Width Y Height Z Interface Page 154 [mm] [mm] [mm] 18 TC-L, TC-F 1 BCD57.1/32.2Q-01/220-240/1-10V 10096387 103 67 30 1-10V 18 TC-L, TC-F 1 BCD57.1/32.2Q-01/220-240/DALI 10096397 103 67 30 DALI, Push-Dim 152 18 TC-L, TC-F 1 BCS39.1FX-11/220-240 10077581 280 30 21 - 120 18 TC-L, TC-F 1 BCS42.1/26.2LS-01/220-240 10095045 150 42 30 - 112 18 TC-L, TC-F 1 BCS42.1/26.2Q-01/220-240 10097545 103 67 30 - 136 18 TC-L, TC-F 1 BCS42.1/26.2QI-01/220-240 10095745 180 86 33 - 140 18 TC-L, TC-F 1 BCS42.1Q-01/220-240 10097535 103 67 30 - 134 18 TC-L, TC-F 1 EBS26.1C-01/220-240 10050992 80 41 19 - 148 18 TC-L, TC-F 1 EBS26.1M-01/220-240 10050996 150 22 22 - 148 116 18 TC-L, TC-F 1 MLD39.1FR-11/220-240/DALI 10097811 360 30 21 DALI, Push-Dim 18 TC-L, TC-F 1 MLS39.1-2FR-11/220-240 10092026 280 30 21 - 112 18 TC-L, TC-F 1 SCS42.1Q-01/220-240/4kV 166772 103 67 30 - 134 154 18 TC-L, TC-F 2 BCD57.1/32.2Q-01/220-240/1-10V 10096387 103 67 30 1-10V 18 TC-L, TC-F 2 BCD57.1/32.2Q-01/220-240/DALI 10096397 103 67 30 DALI, Push-Dim 152 18 TC-L, TC-F 2 BCS39.2FX-11/220-240 10077582 280 30 21 - 120 18 TC-L, TC-F 2 BCS42.1/26.2LS-01/220-240 10095045 150 42 30 - 112 18 TC-L, TC-F 2 BCS42.1/26.2Q-01/220-240 10097545 103 67 30 - 136 18 TC-L, TC-F 2 BCS42.1/26.2QI-01/220-240 10095745 180 86 33 - 140 18 TC-L, TC-F 2 MLD39.2FR-11/220-240/DALI 10092117 360 30 21 DALI, Push-Dim 116 18 TC-L, TC-F 2 MLS39.1-2FR-11/220-240 10092026 280 30 21 - 112 18 TC-L 3 BCD18.3-4F-01/220-240/1-10V 10097171 360 39 21 1-10V 130 18 TC-L, TC-F 3 MLD14/24.3FR-04/220-240/DALI 10105150 360 39 22 DALI, Push-Dim 116 18 TC-L, TC-F 3 MLS14/24.3-4.FR-11/220-240 10095345 280 39 21 - 112 130 18 TC-L 4 BCD18.3-4F-01/220-240/1-10V 10097171 360 39 21 1-10V 18 TC-L, TC-F 4 MLD14/24.4FR-04/220-240/DALI 10105151 360 39 22 DALI, Push-Dim 116 18 TC-L, TC-F 4 MLS14/24.3-4.FR-11/220-240 10095345 280 39 21 - 112 154 24 TC-L, TC-F 1 BCD57.1/32.2Q-01/220-240/1-10V 10096387 103 67 30 1-10V 24 TC-L, TC-F 1 BCD57.1/32.2Q-01/220-240/DALI 10096397 103 67 30 DALI, Push-Dim 152 24 TC-L, TC-F 1 BCS39.1FX-11/220-240 10077581 280 30 21 - 120 24 TC-L, TC-F 1 BCS42.1/26.2LS-01/220-240 10095045 150 42 30 - 112 24 TC-L, TC-F 1 BCS42.1/26.2Q-01/220-240 10097545 103 67 30 - 136 140 24 TC-L, TC-F 1 BCS42.1/26.2QI-01/220-240 10095745 180 86 33 - 24 TC-L, TC-F 1 BCS42.1Q-01/220-240 10097535 103 67 30 - 134 24 TC-L, TC-F 1 EBS26.1C-01/220-240 10050992 80 41 19 - 148 24 TC-L, TC-F 1 EBS26.1M-01/220-240 10050996 150 22 22 - 148 24 TC-L, TC-F 1 MLD39.1FR-11/220-240/DALI 10097811 360 30 21 DALI, Push-Dim 116 24 TC-L, TC-F 1 MLS39.1-2FR-11/220-240 10092026 280 30 21 - 112 24 TC-L, TC-F 1 SCS42.1Q-01/220-240/4kV 166772 103 67 31 - 134 24 TC-L, TC-F 2 BCD57.1/32.2Q-01/220-240/1-10V 10096387 103 67 30 1-10V 154 24 TC-L, TC-F 2 BCD57.1/32.2Q-01/220-240/DALI 10096397 103 67 30 DALI, Push-Dim 152 24 TC-L, TC-F 2 BCS39.2FX-11/220-240 10077582 280 30 21 - 120 24 TC-L, TC-F 2 BCS42.1/26.2LS-01/220-240 10095045 150 42 30 - 112 24 TC-L, TC-F 2 BCS42.1/26.2Q-01/220-240 10097545 103 67 30 - 136 24 TC-L, TC-F 2 BCS42.1/26.2QI-01/220-240 10095745 180 86 33 - 140 24 TC-L, TC-F 2 MLD39.2FR-11/220-240/DALI 10092117 360 30 21 DALI, Push-Dim 116 112 24 TC-L, TC-F 2 MLS39.1-2FR-11/220-240 10092026 280 30 21 - 24 TC-L, TC-F 3 MLD14/24.3FR-04/220-240/DALI 10105150 360 39 22 DALI, Push-Dim 116 24 TC-L, TC-F 3 MLS14/24.3-4.FR-11/220-240 10095345 280 39 21 - 112 24 TC-L, TC-F 4 MLD14/24.4FR-04/220-240/DALI 10105151 360 39 22 DALI, Push-Dim 116 24 TC-L, TC-F 4 MLS14/24.3-4.FR-11/220-240 10095345 280 39 21 - 112 36 TC-L, TC-F 1 BCD36.1F-01/220-240/1-10V 10097144 360 30 21 1-10V 130 36 TC-L, TC-F 1 BCS38.1LS-01/220-240 10097427 150 42 30 - 112 36 TC-L, TC-F 1 BCS38.1Q-01/220-240 10097437 103 67 30 - 134 36 TC-L, TC-F 1 BCS39.1FX-11/220-240 10077581 280 30 21 - 120 36 TC-L, TC-F 1 BCS42.1Q-01/220-240 10097535 103 67 30 - 134 36 TC-L, TC-F 1 MLS39.1-2FR-11/220-240 10092026 280 30 21 - 112 36 TC-L, TC-F 2 BCD36.2F-01/220-240/1-10V 10097194 425 30 21 1-10V 130 36 TC-L, TC-F 2 BCD36.2Q-01/220-240/1-10V 10096326 103 67 30 - 156 36 TC-L, TC-F 2 BCS39.2FX-11/220-240 10077582 280 30 21 - 120 Product Catalogue 2014 | BAG electronics Productfinder - Selection table Power Lamp Number Description of Lamps Order No. [W] Lenght X Width Y Height Z [mm] Interface Page [mm] [mm] 36 TC-L, TC-F 2 MLS39.1-2FR-11/220-240 10092026 280 30 21 - 112 40 TC-L 1 BCD36.1F-01/220-240/1-10V 10097144 360 30 21 1-10V 130 154 40 TC-L 1 BCD57.1/32.2Q-01/220-240/1-10V 10096387 103 67 30 1-10V 40 TC-L 1 BCD57.1/32.2Q-01/220-240/DALI 10096397 103 67 30 DALI, Push-Dim 152 40 TC-L 1 BCS39.1FX-11/220-240 10077581 280 30 21 - 120 40 TC-L 1 BCS42.1/26.2LS-01/220-240 10095045 150 42 30 - 112 40 TC-L 1 BCS42.1/26.2Q-01/220-240 10097545 103 67 30 - 136 40 TC-L 1 BCS42.1/26.2QI-01/220-240 10095745 180 86 33 - 140 40 TC-L 1 BCS42.1Q-01/220-240 10097535 103 67 30 - 134 40 TC-L 1 MLD39.1FR-11/220-240/DALI 10097811 360 30 21 DALI, Push-Dim 116 40 TC-L 1 MLS39.1-2FR-11/220-240 10092026 280 30 21 - 112 130 40 TC-L 2 BCD36.2F-01/220-240/1-10V 10097194 425 30 21 1-10V 40 TC-L 2 BCS39.2FX-11/220-240 10077582 280 30 21 - 120 40 TC-L 2 MLD39.2FR-11/220-240/DALI 10092117 360 30 21 DALI, Push-Dim 116 40 TC-L 2 MLS39.1-2FR-11/220-240 10092026 280 30 21 - 112 55 TC-L 1 BCD55.1F-01/220-240/1-10V 10097079 360 30 21 1-10V 130 55 TC-L 1 BCS54.1FX-11/220-240 10077585 280 30 21 - 120 55 TC-L 1 BCS55.1Q-01/220-240/T5C 10097634 103 67 30 - 134 116 55 TC-L 1 MLD80.1FR-11/220-240/DALI 10097820 360 30 21 DALI, Push-Dim 55 TC-L 1 MLS80.1/54.2FR-11/220-240 10071609 280 30 21 - 112 55 TC-L 2 BCD55.2F-01/220-240/1-10V 10097089 425 30 21 1-10V 130 55 TC-L 2 BCS54.2FX-11/220-240 10077586 280 30 21 - 120 55 TC-L 2 MLD80.2FR-11/220-240/DALI 10101905 425 30 21 DALI, Push-Dim 116 55 TC-L 2 MLS80.1/54.2FR-11/220-240 10071609 280 30 21 - 112 80 TC-L 1 BCD80.1F-01/220-240/1-10V 10097249 360 30 21 1-10V 124 80 TC-L 1 BCS80.1FX-11/220-240 10077587 280 30 21 - 120 80 TC-L 1 MLD80.1FR-11/220-240/DALI 10097820 360 30 21 DALI, Push-Dim 116 80 TC-L 2 BCD80.2F-01/220-240/1-10V 10097299 425 30 21 1-10V 124 80 TC-L 2 MLD80.2FR-11/220-240/DALI 10101905 425 30 21 DALI, Push-Dim 116 TC-L/F BAG electronics | Product Catalogue 2014 111 MLS EVO Non-dimmable electronic control gear for T5 and TC-L lamps with Multi-Lamp-Technology Electronic control gears (non-dimmable) | MLS EVO Product information • Multi-Lamp technology for automatic lamp recognition and optimum operation of T5 and TC-L/F lamps • Luminaire can be fitted with different lamps (e.g. T5: 35W, 49W, 80W) • Compact housing in slim design for space-saving application in luminaires Control gear for FL • Energy-controlled electrode preserving lamp warm start for maximum lamp life irrespective of switching frequency; starting time < 1 s • Cut-Off technology: minimised heat current through electrodes during operation, for optimum light output and reduced power loss. Office & Commercial Outdoor Shop Technical data Conformity EN 61347-1 Mains voltage supply Rated voltage range 220 ... 240 [V] EN 61347-2-3 Rated frequency 0 / 50 ... 60 [Hz] EN 61347-2-3/C Admissible continuous voltage range (AC) 198 - 264 [V] EN 60929 EN 61 00-3-2 Battery operation Voltage range continuous DC 198 VDC - 278 VDC Voltage short time DC min. 176 VDC Overvoltage protection (time) 350V / 2 h Max. leakage current 0.5 mA EN 6100-3-3 EN 61547 EN 55015 • Automatic restart after lamp replacement • Safety switch-off in case of abnormal lamp operation, e. g. defective electrode and end of lamp life; tested acc. to EN 61347-2-3 + Test 2 • Constant lamp output independent of mains voltage fluctuations • Optimum ignition safety even at low temperatures: automatic second start if necessary • Automatic restart after lamp replacement • Suitable for direct current operation and emergency lighting installations; complies with requirements for emergency lighting according to EN 61347- 2-3/J • Quick restart of lamps after short power disruptions • Connecting earth can be disregarded in suitable luminaires with safety classification II • Energy efficiency EEI = A2BAT • Nominal service life: 50.000 h with failure rate of ≤ 10% and operation at tc=tc,max 112 Industry Product Catalogue 2014 | BAG electronics Designations Operating data Lamp designation W W A kHz MLS80.1FR-11/220-240 10071608 1 x T5 28 32 0.15 90 0.97 28 3 ENEC, EMV 1 x T5 35 39 0.18 90 0.97 35 3 ENEC, EMV LS80.1/54.2FR-11/220-240 MLS39.1-2FR-11/220-240 MLS14/24.3-4.FR-11/ 220-240 10071609 10092026 10095345 System rating Input current Operation frequency Power factor Rated power lamps Picture reference Approval for lamps 1 x T5 49 53.5 0.24 75 0.97 49 3 ENEC, EMV 1 x T5 54 60 0.27 42 0.97 54 3 ENEC, EMV 1 x T5 80 86 0.37 41 0.97 80 3 ENEC, EMV 1 x T5 28 32 0.15 67 0.93 28 23 ENEC, EMV 2 x T5 28 64 0.28 63 0.98 28 23 ENEC, EMV 1 x T5 35 39 0.18 66 0.95 35 23 ENEC, EMV 2 x T5 35 80 0.35 62 0.99 35 23 ENEC, EMV 1 x T5 49 55 0.24 57 0.97 49 23 ENEC, EMV 2 x T5 49 104 0.45 59 0.99 49 23 ENEC, EMV 1 x T5 54 60 0.26 47 0.98 54 23 ENEC, EMV 2 x T5 54 113 0.48 47 0.99 54 23 ENEC, EMV 1 x T5 80 86 0.37 46 0.99 80 23 ENEC, EMV 1 x TC-L 55 56 0.25 47 0.98 55 23 ENEC, EMV 2 x TC-L 55 105 0.43 47 0.99 55 23 ENEC, EMV 1 x T5 14 17 0.08 98 0.85 14 23 ENEC, EMV 2 x T5 14 33 0.15 86 0.93 14 23 ENEC, EMV 1 x T5 21 24.5 0.11 92 0.9 21 23 ENEC, EMV 2 x T5 21 48 0.20 82 0.97 21 23 ENEC, EMV 1 x T5 24 28 0.12 67 0.92 24 23 ENEC, EMV 2 x T5 24 54 0.23 66 0.97 24 23 ENEC, EMV 1 x T5 39 42 0.17 67 0.96 39 23 ENEC, EMV 2 x T5 39 82 0.35 66 0.98 39 23 ENEC, EMV 1 x TC-L 18 19 0.09 66 0.9 16 23 ENEC, EMV 2 x TC-L 18 35.5 0.15 67 0.94 16 23 ENEC, EMV 1 x TC-F 18 19 0.09 66 0.9 16 23 ENEC, EMV 2 x TC-F 18 35.5 0.15 67 0.94 16 23 ENEC, EMV 1 x TC-L 24 27 0.12 67 0.92 22 23 ENEC, EMV 2 x TC-L 24 50 0.23 67 0.97 22 23 ENEC, EMV 1 x TC-F 24 27 0.12 67 0.92 22 23 ENEC, EMV 2 x TC-F 24 50 0.23 67 0.97 22 23 ENEC, EMV 1 x TC-L 36 34.5 0.14 67 0.94 32 23 ENEC, EMV 2 x TC-L 36 69 0.29 67 0.98 32 23 ENEC, EMV 1 x TC-F 36 34.5 0.14 67 0.94 32 23 ENEC, EMV 2 x TC-F 36 69 0.29 67 0.98 32 23 ENEC, EMV 1 x TC-L 40 43.5 0.20 67 0.96 40 23 ENEC, EMV 2 x TC-L 40 88 0.38 67 0.98 40 23 ENEC, EMV 3 x T5 14 W 51 0.23 66 kHz 0.96 14 15, 66 ENEC, EMV 4 x T5 14 W 61 0.27 66 kHz 0.98 14 15, 66 ENEC, EMV 3 x T5 24 W 80 0.35 52 kHz 0.99 24 15, 66 ENEC, EMV 3 x TC-L 18 W 54 0.24 52 kHz 0.97 16 25, 29 ENEC, EMV 4 x TC-L 18 W 70 0.30 52 kHz 0.98 16 25, 29 ENEC, EMV 3 x TC-L 24 W 79 0.35 52 kHz 0.98 22 25, 29 ENEC, EMV ENEC, EMV 4 x TC-L 24 W 98 0.43 52 kHz 0.99 22 25, 29 3 x T8 36 W 105 0.46 52 kHz 0.99 32 15 ENEC, EMV 4 x T5 24 W 98 0.43 52 kHz 0.99 24 15, 66 ENEC, EMV BAG electronics | Product Catalogue 2014 Electronic control gears (non-dimmable) | MLS EVO Materialnumber Control gear for FL Designation 113 Dimensions | weights | temperatures Short designation Length X Width Y Height Z Hole spacing XM (length direction) mm mm mm mm mm MLS80.1FR-11 280 30 21 270 MLS80.1 / 54.2FR-11 280 30 21 MLS39.1-2FR-11 280 30 21 MLS14 / 24.3-4FR-11 280 39 21 Hole spacing ZM (height direction) Diagram Weight kg °C °C 8.5 B 0.230 -25 ... 55 70 270 8.5 B 0.247 -25 ... 55 75 270 8.5 B 0.217 -25 ... 55 75 270 9 B 0.265 -20 ... 50 75 Case drawing Y Z ZM B XM X Electronic control gears (non-dimmable) | MLS EVO Wiring diagrams 3 25 1 2 3 4 Control gear for FL 1 2 3 4 5 6 7 8 9 10 1 2 9 10 1 2 3 4 5 6 7 8 9 10 15 1 2 3 4 5 6 7 8 9 10 1 2 9 10 23 1 2 3 4 5 6 66 1 2 9 10 114 1 2 9 10 1 2 3 4 5 6 7 8 9 10 Product Catalogue 2014 | BAG electronics 29 Ambient temperature ta Housing temperature tc,max BAG electronics | Product Catalogue 2014 115 Control gear for FL Electronic control gears (non-dimmable) | MLS EVO MLD EVO DALI DALI dimmable electronic control gear for T5 and TC-L lamps with Multi-Lamp-Technology Electronic control gears (dimmable) | MLD EVO DIM DALI Product information • Multi-Lamp technology for automatic lamp recognition and optimum operation of T5 and TC-L/F lamps • Twingle operation with 1 or 2 lamps* • Luminaire can be fitted with different lamps (e.g. T5: 35W, 49W, 80W) Control gear for FL • Compact housing in slim design for space-saving application in luminaires • Energy-controlled electrode preserving lamp warm start for maximum lamp life irrespective of switching frequency; starting time < 1 s • Cut-Off technology: minimised heat current through electrodes during operation, for optimum light output and reduced power loss. • Automatic restart after lamp replacement • Safety switch-off in case of abnormal lamp operation, e. g. defective electrode and end of lamp life; tested acc. to EN 61347-2-3 + Test 2 Industry Office & Commercial Outdoor Shop Technical data Conformity EN 61347-1 Mains voltage supply Rated voltage range 220 ... 240 [V] EN 61347-2-3 Rated frequency 0 / 50 ... 60 [Hz] EN 61347-2-3/C Admissible continuous voltage range (AC) 198 - 264 [V] EN 60929 EN 62386-102 Battery operation Voltage range continuous DC 198 VDC - 278 VDC Voltage short time DC min. 176 VDC Overvoltage protection (time) 350V / 2 h Overvoltage protection DALI interface 264 V / permanent Max. leakage current 0.5 mA EN 61 00-3-2 EN 6100-3-3 EN 61547 EN 55015 Designations • Constant lamp output independent of mains voltage fluctuations • Optimum ignition safety even at low temperatures: automatic second start if necessary • Automatic restart after lamp replacement • Suitable for direct current operation and emergency lighting installations; complies with requirements for emergency lighting according to EN 61347- 2-3/J • Quick restart of lamps after short power disruptions • Connecting earth can be disregarded in suitable luminaires with safety classification II • Energy efficiency EEI = A2/A2BAT • Nominal service life: 50.000 h with failure rate of ≤ 10% and operation at tc=tc,max 116 Product Catalogue 2014 | BAG electronics push Operating data Lamp designation W W A kHz MLD39.2FR-11/ 220-240/DALI 10092117 2 x T5 14 33 0.15 69 ... 120 0.94 14 99 ENEC, EMV 2 x T5 21 45 0.20 72 ... 120 0.97 21 99 ENEC, EMV MLD54.2FR-11/ 220-240/DALI MLD39.1FR-11/ 220-240/DALI MLD54.1FR-11/ 220-240/DALI MLD80.1FR-11/ 220-240/DALI MLD80.2FR-11/ 220-240/DALI MLD14/24.3FR-04 /220-240/DALI MLD14/24.4FR-04 /220-240/DALI 10092121 10097811 10097815 10097820 10101905 10105150 10105151 System rating Input current Operation frequency Power factor Rated power lamps Picture reference Approval for lamps 2 x T5 24 49 0.22 40 ... 120 0.97 24 99 ENEC, EMV 2 x T5 39 79 0.35 40 ... 120 0.99 39 99 ENEC, EMV 2 x TC-F 18 36 0.16 40 ... 120 0.97 16 99 ENEC, EMV 2 x TC-F 24 48 0.22 40 ... 120 0.97 22 99 ENEC, EMV 2 x TC-L 18 36 0.16 40 ... 120 0.97 16 99 ENEC, EMV 2 x TC-L 24 48 0.22 40 ... 120 0.97 22 99 ENEC, EMV 2 x TC-L 40 85 0.37 40 ... 120 0.99 40 99 ENEC, EMV 2 x T5 28 63 0.28 40 ... 120 0.98 28 99 ENEC, EMV 2 x T5 35 78 0.34 40 ... 120 0.99 35 99 ENEC, EMV 2 x T5 49 104 0.45 40 ... 120 0.99 49 99 ENEC, EMV 2 x T5 54 115 0.51 40 ... 120 0.99 54 99 ENEC, EMV 1 x T5 14 17 0.09 99 ... 120 0.9 14 20. 28, 58 ENEC, EMV 1 x T5 21 22 0.11 96 ... 120 0.92 21 20. 28, 58 ENEC, EMV 1 x T5 24 28 0.13 69 ... 120 0.93 24 20. 28, 58 ENEC, EMV 1 x T5 39 39 0.18 71 ... 100 0.96 39 20. 28, 58 ENEC, EMV 1 x TC-F 18 19 0.09 64 ... 120 0.9 16 20. 28, 58 ENEC, EMV 1 x TC-F 24 26 0.12 69 ... 120 0.94 22 20. 28, 58 ENEC, EMV 1 x TC-L 18 19 0.09 64 ... 120 0.9 16 20. 28, 58 ENEC, EMV 1 x TC-L 24 26 0.12 69 ... 120 0.94 22 20. 28, 58 ENEC, EMV 1 x TC-L 40 41 0.18 73 ... 100 97 40 20. 28, 58 ENEC, EMV 1 x T5 28 33 0.16 90 ... 100 0.94 28 20. 28, 58 ENEC, EMV 1 x T5 35 40 0.17 87 ... 100 0.95 35 20. 28, 58 ENEC, EMV 1 x T5 49 55 0.25 79 ... 100 0.98 49 20. 28, 58 ENEC, EMV 1 x T5 54 56 0.27 52 ... 100 0.99 54 20. 28, 58 ENEC, EMV 1 x T5 35 39 0.17 88 ... 100 0.96 35 20. 28, 58 ENEC, EMV 1 x T5 49 55 0.25 79 ... 100 0.98 49 20. 28, 58 ENEC, EMV 1 x T5 80 81 0.38 45 ... 100 0.99 80 20. 28, 58 ENEC, EMV 1 x TC-L 55 68 0.28 46 ... 100 0.99 55 20. 28, 58 ENEC, EMV 1 x TC-L 80 83 0.38 45 ... 100 0.99 80 20. 28, 58 ENEC, EMV 2 x T5 35 77 0.34 42 ... 115 0.98 35 99, 28, 58 ENEC, EMV 2 x T5 49 101 0.46 42 ... 115 0.99 49 99, 28, 58 ENEC, EMV 2 x T5 80 177 0.74 42 ... 115 0.99 80 99, 28, 58 ENEC, EMV 2 x TC-L 55 125 0.47 42 ... 115 0.99 55 99, 28, 58 ENEC, EMV 2 x TC-L 80 177 0.74 42 ... 115 0.99 80 99, 28, 58 ENEC, EMV 3 x T5 14 49 0.22 42 ... 110 0.95 14 24, 55, 65 ENEC, EMV 3 x T5 24 77 0.35 42 ... 110 0.95 24 24, 55, 65 ENEC, EMV 3 x TC-L 18 50 0.23 42 ... 110 0.95 16 24, 55, 65 ENEC, EMV 3 x TC-L 24 75 0.34 42 ... 110 0.95 22 24, 55, 65 ENEC, EMV 3 x T8 18 58 0.27 42 ... 110 0.95 16 24, 55, 65 ENEC, EMV 4 x T5 14 63 0.29 42 ... 110 0.95 14 26, 55, 65 ENEC, EMV ENEC, EMV 4 x T5 24 103 0.47 42 ... 110 0.95 24 26, 55, 65 4 x TC-L 18 71 0.32 42 ... 110 0.95 16 26, 55, 65 ENEC, EMV 4 x TC-L 24 100 0.46 42 ... 110 0.95 22 26, 55, 65 ENEC, EMV 4 x T8 18 75 0.34 42 ... 110 0.95 16 26, 55, 65 ENEC, EMV Diagram Weight Ambient temperature ta kg °C °C B, M 0.265 5 ... 55 75 Electronic control gears (dimmable) | MLD EVO DIM DALI Materialnumber Control gear for FL Designation Dimensions | weights | temperatures Short designation Length X Width Y Height Z Hole spacing XM (length direction) mm mm mm mm mm MLD39.2FR-11 360 30 21 350 9 Hole spacing ZM (height direction) Housing temperature tc,max MLD54.2FR-11 360 30 21 350 9 B, M 0.318 5 ... 55 75 MLD39.1FR-11 360 30 21 350 9 B, M 0.270 5 ... 60 75 MLD54.1FR-11 360 30 21 350 9 B, M 0.275 5 ... 60 75 MLD80.1FR-01 360 30 21 350 9 B, M 0.275 5 ... 60 75 MLD80.2FR-11 425 30 21 415 9 B, M 0.366 5 ... 55 75 MLD14 / 24.3FR-04 360 39 22 350 - B, M 0.370 5 ... 50 75 MLD14 / 24.4FR-04 360 39 22 350 - B, M 0.380 5 ... 50 75 BAG electronics | Product Catalogue 2014 117 Case drawing M Y Y Z Z ZM ZM B XM X XM X Wiring diagrams 20 28 Electronic control gears (dimmable) | MLD EVO DIM DALI DA DA 1 2 3 4 Push-DIM L N PE L N DA DA Push-DIM L N DA DALI DA 24 ▼ ▼ ▼ ▼ ▼ DA DA Push-DIM L N 1 2 3 4 55 5 6 PE L N 7 8 9 10 DA DA Push-DIM L N 26 DA DA Control gear for FL Push-DIM L N DA DALI DA 1 2 3 4 ▼ ▼ ▼ ▼ ▼ 5 6 58 PE L N 7 8 9 10 Taster DA DA 99 DA DA Push-DIM L N 1 2 3 4 5 6 7 ▼ ▼ ▼ Push-DIM L N ▼ 65 PE L N Taster DA DA ▼ ▼ ▼ 118 Product Catalogue 2014 | BAG electronics ▼ Push-DIM L N BAG electronics | Product Catalogue 2014 119 Control gear for FL Electronic control gears (dimmable) | MLD EVO DIM DALI BCS PRIMUS T5 Non-dimmable electronic control gear for T5 and TC-L/F lamps Electronic control gears (non-dimmable) | BCS PRIMUS T5 Product information • Short housing in flat design for space-saving application in luminaires • Multipower - Technology for operation with different lamps on the same control gear Control gear for FL • Energy controlled, electrode preserving lamp warm start for maximum lamp life irrespective of switching frequency; starting time < 1,5 s • Cut-Off technology: minimised heat current through electrodes during operation, for optimum light output and reduced power loss. • Safety switch-off in case of abnormal lamp operation, e. g. defective electrode and end of lamp life; tested acc. to EN 61347-2-3 + Test 2 • Flimmer free light through high frequency lamp operation, no stroboscope effect • Constant lamp output independent of mains voltage fluctuations • Optimum ignition safety even at low temperatures: automatic second start if necessary • Automatic restart after lamp replacement • Suitable for direct current operation and emergency lighting installations; complies with requirements for emergency lighting according to EN 61347- 2-3/J • Quick restart of lamps after short power disruptions • Connecting earth can be disregarded in suitable luminaires with safety classification II • Energy efficiency EEI= A2BAT • Extended nominal service life*: 75.000 h at tc=tc,max with failure rate of ≤ 10% 100.000 h operation at tc=tc,max -10 K with failure rate ≤ 10 % 120 Product Catalogue 2014 | BAG electronics Industry Office & Commercial Outdoor Shop Technical data Conformity EN 61347-1 Mains voltage supply Rated voltage range 220 ... 240 [V] EN 61347-2-3 Rated frequency 0 / 50 ... 60 [Hz] EN 61347-2-3/C Admissible continuous voltage range (AC) 198 - 264 [V] EN 60929 EN 61 00-3-2 Battery operation Voltage range continuous DC 198 VDC - 278 VDC Voltage short time DC min. 176 VDC Overvoltage protection (time) 350 V / 2 h, 350V / 2h Max. leakage current 0.5 mA EN 6100-3-3 EN 61547 EN 55015 Designations Operating data Lamp designation W W A kHz BCS14.3-4FR-01/220-240 10052868 3 x T5 14 47 0.22 50 0.96 14 52 ENEC, EMV 4 x T5 14 59 0.26 50 0.96 14 53 ENEC, EMV BCS35.1FX-11/220-240 BCS35.2FX-11/220-240 BCS39.1FX-11/220-240 BCS39.2FX-11/220-240 10077579 10077580 10077581 10077582 System rating Input current Operation frequency Power factor Rated power lamps Picture reference Approval for lamps 1 x T5 14 17 0.08 48 0.93 14 3 ENEC, EMV 1 x T5 21 24 0.10 48 0.96 21 3 ENEC, EMV 1 x T5 28 31 0.14 48 0.98 28 3 ENEC, EMV 1 x T5 35 39 0.17 48 0.99 35 3 ENEC, EMV 2 x T5 14 31 0.15 51 0.97 14 23 ENEC, EMV 2 x T5 21 47 0.21 51 0.97 21 23 ENEC, EMV 2 x T5 28 64 0.28 51 0.97 28 23 ENEC, EMV 2 x T5 35 74 0.34 51 0.97 35 23 ENEC, EMV 1 x T5 24 27 0.12 44 0.98 24 3 ENEC, EMV 1 x T5 39 41 0.18 44 0.97 39 3 ENEC, EMV 1 x T8 18 18 0.08 45 0.99 16 3 - 1 x T8 36 36 0.16 45 0.99 32 3 - 1 x TC-F 18 19 0.08 44 0.96 16 3 ENEC, EMV 1 x TC-F 24 26 0.12 44 0.98 22 3 ENEC, EMV 1 x TC-F 36 37 0.16 44 0.99 32 3 ENEC, EMV 1 x TC-L 18 19 0.08 44 0.96 16 3 ENEC, EMV 1 x TC-L 24 26 0.12 44 0.98 22 3 ENEC, EMV 1 x TC-L 36 37 0.16 44 0.99 32 3 ENEC, EMV 1 x TC-L 40 41 0.18 44 0.99 40 3 ENEC, EMV 2 x T5 24 53 0.24 42 0.98 24 23 ENEC, EMV 2 x T5 39 82 0.35 42 0.99 39 23 ENEC, EMV 2 x TC-L 18 34 0.15 42 0.96 16 23 ENEC, EMV 2 x TC-L 24 50 0.23 42 0.98 22 23 ENEC, EMV 2 x TC-L 36 67 0.29 42 0.99 32 23 ENEC, EMV 2 x TC-L 40 86 0.35 42 0.99 40 23 ENEC, EMV 2 x TC-F 18 34 0.15 42 0.96 16 23 ENEC, EMV 2 x TC-F 24 50 0.23 42 0.98 22 23 ENEC, EMV 2 x TC-F 36 67 0.29 42 0.99 32 23 ENEC, EMV BCS49.1FX-11/220-240 10077583 1 x T5 49 54 0.23 52 0.99 49 3 ENEC, EMV BCS49.2FX-11/220-240 10077584 2 x T5 49 109 0.48 52 0.99 49 23 ENEC, EMV BCS54.1FX-11/220-240 10077585 1 x T5 54 59 0.26 49 0.99 54 3 ENEC, EMV 1 x T8 58 55 0.25 49 0.99 58 3 ENEC, EMV 1 x TC-L 55 59 0.26 49 0.99 55 3 ENEC, EMV BCS54.2FX-11/220-240 10077586 2 x T5 54 107 0.47 46 0.99 54 23 ENEC, EMV 2 x TC-L 55 108 0.47 46 0.99 55 23 ENEC, EMV BCS80.1FX-11/220-240 10077587 1 x T5 80 87 0.38 47 0.99 80 3 ENEC, EMV 1 x TC-L 80 87 0.38 47 0.99 80 3 ENEC Electronic control gears (non-dimmable) | BCS PRIMUS T5 Materialnumber Control gear for FL Designation Dimensions | weights | temperatures Short designation Length X Width Y Height Z Hole spacing XM (length direction) mm mm mm mm mm BCS14.3-4FR-01 280 42 21 270 BCS35.1FX-11 280 30 21 BCS35.2FX-11 280 30 21 BCS39.1FX-11 280 30 BCS39.2FX-11 280 BCS49.1FX-11 Hole spacing ZM (height direction) Diagram Weight Ambient temperature ta Housing temperature tc,max kg °C °C 9 B 0.250 -20 ... 60 70 270 9 B 0.177 -20 ... 60 75 270 9 B 0.205 -20 ... 55 70 21 270 9 B 0.174 -20 ... 60 75 30 21 270 9 B 0.192 -20 ... 55 75 280 30 21 270 9 B 0.184 -20 ... 60 70 BCS49.2FX-11 280 30 21 270 9 B 0.221 -20 ... 55 75 BCS54.1FX-11 280 30 21 270 9 B 0.185 -20 ... 60 75 BCS54.2FX-01 280 30 21 270 9 B 0.204 -20 ... 55 80 BCS80.1FR-01 280 30 21 270 9 B 0.189 -20 ... 55 75 BAG electronics | Product Catalogue 2014 121 Case drawing Y Z Zm B Xm X Wiring diagrams 3 Electronic control gears (non-dimmable) | BCS PRIMUS T5 Control gear for FL 122 1 2 3 4 23 1 2 3 4 5 6 52 1 2 7 8 9 10 1 2 3 4 5 6 53 1 2 7 8 9 10 1 2 3 4 5 6 Product Catalogue 2014 | BAG electronics BAG electronics | Product Catalogue 2014 123 Control gear for FL Electronic control gears (non-dimmable) | BCS PRIMUS T5 BCD T5 1-10V Dimmable electronic control gear for T5 lamps Electronic control gears (dimmable) | BCD T5 1-10V Product information • Dimming interface: 1–10 V • Dimming range 1...100% luminous flux • Energy controlled, electrode preserving lamp warm start for maximum lamp life irrespective of switching frequency; starting time < 1,5 s Control gear for FL • Cut-Off technology at 100% luminous flux: minimised heat current through electrodes during operation, for optimum light output and reduced power loss. • Automatic restart after lamp replacement • Safety switch-off in case of abnormal lamp operation, e. g. defective electrode and end of lamp life; tested acc. to EN 61347-2-3 • Suitable for direct current operation and emergency lighting installations; complies with requirements for emergency lighting according to EN 61347- 2-3/J • Energy efficiency index EEI=A1 • Nominal service life: 50.000 h with failure rate of ≤ 10% and operation at tc=tc,max 124 Product Catalogue 2014 | BAG electronics Industry Office & Commercial Outdoor Shop Technical data Conformity EN 61347-1 Mains voltage supply Rated voltage range 220 ... 240 [V] EN 61347-2-3 Rated frequency 0 / 50 ... 60 [Hz] EN 61347-2-3/C Admissible continuous voltage range (AC) 198 ... 264 [V] EN 60929 EN 61 00-3-2 Battery operation Voltage range continuous DC 198 VDC - 278 VDC Voltage short time DC min. 176 VDC Overvoltage protection (time) 350V / 2 h Max. leakage current 0.5 mA Max. control current (1-10V) 0.2 mA EN 6100-3-3 EN 61547 EN 55015 Designations Operating data Materialnumber Lamp designation W W A kHz BCD35.1F-01/ 220-240/1-10V 10097244 1 x T5 14 18 0.08 50 ... 85 0.96 14 64 ENEC 1 x T5 21 25 0.12 50 ... 85 0.96 21 64 ENEC 10097246 BCD49.1F-01/ 220-240/1-10V Input current Operation frequency Power factor Rated power lamps Picture reference Approval for lamps 1 x T5 28 32 0.15 50 ... 85 0.96 28 64 ENEC 1 x T5 35 39 0.19 50 ... 85 0.96 35 64 ENEC 1 x T5 24 26 0.12 45 ... 105 0.98 24 64 ENEC 1 x T5 39 38.5 0.17 45 ... 105 0.98 39 64 ENEC 10097247 1 x T5 49 55 0.24 55 ... 80 0.97 49 64 ENEC BCD54.1F-01/ 220-240/1-10V 10097248 1 x T5 54 58 0.26 55 ... 120 0.97 54 64 ENEC BCD80.1F-01/ 220-240/1-10V 10097249 BCD14.3F-01/ 220-240/1-10V 1 x T5 80 86 0.37 45 ... 115 0.98 80 64 ENEC 1 x TC-L 80 86 0.37 45 ... 115 0.98 80 64 ENEC 10097281 3 x T5 14 50 0.22 56 ... 66 0.95 14 76 ENEC BCD14.4F-01/ 220-240/1-10V 10097291 4 x T5 14 66 0.29 48 ... 80 0.95 14 75 ENEC BCD35.2F-01/ 220-240/1-10V 10097294 BCD39.2F-01/ 220-240/1-10V 10097296 BCD49.2F-01/ 220-240/1-10V 2 x T5 14 34 0.15 45 ... 90 0.97 14 74 ENEC 2 x T5 21 48 0.21 45 ... 90 0.97 21 74 ENEC 2 x T5 28 64 0.28 45 ... 90 0.97 28 74 ENEC 2 x T5 35 78 0.35 45 ... 90 0.97 35 74 ENEC 2 x T5 24 53 0.23 40 ... 110 0.97 24 74 ENEC 2 x T5 39 78 0.34 40 ... 110 0.97 39 74 ENEC 10097297 2 x T5 49 106 0.47 50 ... 90 0.98 49 74 ENEC BCD54.2F-01/ 220-240/1-10V 10097298 2 x T5 54 115 0.51 40 ... 145 0.97 54 74 ENEC BCD80.2F-01/ 220-240/1-10V 10097299 2 x T5 80 172 0.75 45 ... 120 0.97 80 74 ENEC 2 x TC-L 80 172 0.75 45 ... 120 0.97 80 74 ENEC Dimensions | weights | temperatures Short designation Length X Width Y Height Z Hole spacing XM (length direction) mm mm mm mm mm BCD35.1F-01 360 30 21 350 BCD39.1F-01 360 30 21 BCD49.1F-01 360 30 21 BCD54.1F-01 360 30 BCD80.1F-01 360 30 BCD14.3F-01 360 BCD14.4F-01 BCD35.2F-01 Hole spacing ZM (height direction) Diagram Weight Ambient temperature ta kg °C °C 9 M 0.250 5 ... 55 75 350 9 M 0.246 5 ... 55 70 350 9 M 0.252 5 ... 55 70 21 350 9 M 0.262 5 ... 55 70 21 350 9 M 0.262 5 ... 55 70 39 21 350 9 M 0.325 5 ... 60 75 360 39 21 350 9 M 0.317 5 ... 60 75 420 30 20 415 9 M 0.328 5 ... 55 75 BCD39.2F-01 425 30 21 415 9 M 0.328 5 ... 55 70 BCD49.2F-01 425 30 21 415 9 M 0.356 5 ... 55 70 BCD54.2F-01 425 30 21 415 9 M 0.330 5 ... 55 75 BCD80.2F-01 425 30 21 415 9 M 0.386 5 ... 55 75 Housing temperature tc,max Control gear for FL BCD39.1F-01/ 220-240/1-10V System rating Electronic control gears (dimmable) | BCD T5 1-10V Designation Case drawing Y Z ZM M XM X BAG electronics | Product Catalogue 2014 125 Wiring diagrams 64 1 2 3 4 1−10 V 74 1−10 V Electronic control gears (dimmable) | BCD T5 1-10V Control gear for FL 126 1 2 3 4 5 6 7 75 17 16 15 14 n.c. 1 2 3 4 5 6 7 + 1-10V – 76 17 16 15 14 n.c. 1 2 3 4 5 6 7 + 1-10V – Product Catalogue 2014 | BAG electronics BAG electronics | Product Catalogue 2014 127 Control gear for FL Electronic control gears (dimmable) | BCD T5 1-10V BCS PRIMUS T8 Non-dimmable electronic control gear for T8 lamps Electronic control gears (non-dimmable) | BCS PRIMUS T8 Product information • Short housing in flat design for space-saving application in luminaires • Energy controlled, electrode preserving lamp warm start for maximum lamp life irrespective of switching frequency; starting time < 1,5 s Control gear for FL • Cut-Off technology: minimised heat current through electrodes during operation, for optimum light output and reduced power loss. • Safety switch-off in case of abnormal lamp operation, e. g. defective electrode and end of lamp life; tested acc. to EN 61347-2-3 + Test 2 • Flimmer free light through high frequency lamp operation, no stroboscope effect • Constant lamp output independent of mains voltage fluctuations • Optimum ignition safety even at low temperatures: automatic second start if necessary • Automatic restart after lamp replacement • Suitable for direct current operation and emergency lighting installations; complies with requirements for emergency lighting according to EN 61347- 2-3/J • Constant light output irrespective of mains power fluctuation • Quick restart of lamps after short power disruptions • Connecting earth can be disregarded in suitable luminaires with safety classification II • Energy efficiency EEI= A2BAT • Extended nominal service life*: 75.000 h at tc=tc,max with failure rate of ≤ 10% 100.000 h operation at tc=tc,max -10 K with failure rate ≤ 10 % 128 Product Catalogue 2014 | BAG electronics Industry Office & Commercial Outdoor Shop Technical data Conformity EN 61347-1 Mains voltage supply Rated voltage range 220 ... 240 [V] EN 61347-2-3 Rated frequency 0 / 50 ... 60 [Hz] EN 61347-2-3/C Admissible continuous voltage range (AC) 198 - 264 [V] EN 60929 EN 61 00-3-2 Battery operation Voltage range continuous DC 198 VDC - 278 VDC Voltage short time DC min. 176 VDC Overvoltage protection (time) 350V /2 h Max. leakage current 0.5 mA EN 6100-3-3 EN 61547 EN 55015 Designations Operating data Designation Material number Lamp designation System rating Input current Operation frequency Power factor Rated power lamps Picture reference Approval for lamps W W A kHz BCS18.3-4LR-01/220-240 10050999 3 x T8 18 58 0.26 47 0.98 16 50 ENEC, EMV 4 x T8 18 76 0.33 47 0.99 16 51 ENEC, EMV BCS18.1FX-11/220-240 10077588 1 x T8 18 19 0.08 49 0.97 16 3 ENEC, EMV BCS18.2FX-11/220-240 10077589 2 x T8 18 36 0.16 45 0.97 16 23 ENEC, EMV BCS36.1FX-11/220-240 10077590 1 x T8 36 35 0.16 44 0.97 32 3 ENEC, EMV BCS36.2FX-11/220-240 10077591 2 x T8 36 71 0.32 45 0.99 32 23 ENEC, EMV BCS58.1FX-11/220-240 10077592 1 x T8 58 55 0.25 45 0.99 58 3 ENEC, EMV BCS58.2FX-11/220-240 10077593 2 x T8 58 108 0.50 45 0.99 58 23 ENEC, EMV Short designation Length X Width Y Height Z Hole spacing XM (length direction) mm mm mm mm mm BCS18.3-4LR-01 290 42 28 280 BCS18.1FX-11 280 30 21 BCS18.2FX-11 280 30 21 BCS36.1FX-11 280 30 BCS36.2FX-11 280 30 BCS58.1FX-11 280 BCS58.2FX-11 280 Hole spacing ZM (height direction) Diagram Weight Ambient temperature ta kg °C °C - B 0.270 -20 ... 60 75 265 9 B 0.183 -20 ... 60 75 265 9 B 0.177 -20 ... 60 75 21 265 9 B 0.183 -20 ... 60 75 21 265 9 B 0.191 -20 ... 60 75 30 21 265 9 B 0.185 -20 ... 60 75 30 21 265 9 B 0.209 -20 ... 55 75 Housing temperature tc,max Case drawing Y Z ZM B Electronic control gears (non-dimmable) | BCS PRIMUS T8 Dimensions | weights | temperatures XM Control gear for FL X Wiring diagrams 3 50 1 2 3 4 5 6 7 8 9 10 23 1 2 3 4 5 6 1 2 3 4 5 6 51 5 6 7 8 9 10 1 2 3 4 5 6 BAG electronics | Product Catalogue 2014 129 BCD T8 1-10V Dimmable electronic control gear for T8- and TC-L/F lamps Electronic control gears (dimmable) | BCD T8 1-10V Product information • Dimming interface: 1–10 V • Dimming range 1...100% luminous flux • Multi-Power technology for operation of different lamps and wattages on the same ECG Control gear for FL • Electrode preserving warm start for maximum lamp life, even at increased switching frequency; starting time < 1.5 s Office & Commercial Outdoor Shop Technical data Conformity EN 61347-1 Mains voltage supply Rated voltage range 220 ... 240 [V] EN 61347-2-3 Rated frequency 0 / 50 ... 60 [Hz] EN 61347-2-3/C Admissible continuous voltage range (AC) 198 - 264 [V] EN 60929 EN 61 00-3-2 Battery operation Voltage range continuous DC 198 VDC - 278 VDC Voltage short time DC min. 176 VDC • Cut-Off technology at 100% luminous flux: minimised heat current through electrodes during operation, for optimum light output and reduced power loss. Overvoltage protection (time) 350 V / 2 h • Automatic restart after lamp replacement Max. leakage current 0.5 mA Max. control current (1-10V) 0.2 mA • Safety switch-off in case of abnormal lamp operation, e. g. defective electrode and end of lamp life; tested acc. to EN 61347-2-3 • Suitable for direct current operation and emergency lighting installations; complies with requirements for emergency lighting according to EN 61347- 2-3/J • Energie efficiency EEI=A1 • Nominal service life: 50.000 h with failure rate of ≤ 10% and operation at tc=tc,max 130 Industry Product Catalogue 2014 | BAG electronics EN 6100-3-3 EN 61547 EN 55015 Designations Material number Lamp designation W W A kHz BCD55.1F-01/ 220-240/1-10V 10097079 1 x TC-L 55 59 0.27 BCD55.2F-01/ 220-240/1-10V 10097089 2 x TC-L 55 122 0.54 BCD18.1F-01/ 220-240/1-10V 10097143 BCD36.1F-01/ 220-240/1-10V 10097144 BCD58.1F-01/ 220-240/1-10V 10097145 BCD18.3-4F-01/ 220-240/1-10V 10097171 System rating Input current Operation frequency Power factor Rated power lamps Picture reference Approval for lamps 45 ... 120 0.98 55 64 ENEC 50 ... 140 0.98 55 74 ENEC ENEC 1 x T8 18 19 0.09 50 ... 100 0.96 16 64 1 x T8 30 30 0.13 50 ... 100 0.96 30 64 45 ... 90 1 x T8 36 36 0.16 1 x TC-F 36 36 0.16 0.98 32 64 ENEC 0.98 32 64 ENEC 1 x TC-L 36 36 0.21 0.98 32 64 ENEC 1 x TC-L 40 46 0.21 45 ... 90 0.98 40 64 ENEC 1 x T8 58 57 0.25 50 ... 110 0.97 58 64 ENEC 3 x T5 24 76 0.33 47 ... 75 0.95 24 76 ENEC 3 x T8 18 47 0.25 47 ... 75 0.95 16 76 ENEC 3 x TC-L 18 57 0.25 47 ... 75 0.95 16 76 ENEC 4 x T8 18 74 0.32 47 ... 75 0.95 16 77 ENEC 4 x TC-L 18 74 0.32 47 ... 75 0.95 16 77 ENEC BCD18.2F-01/ 220-240/1-10V 10097193 2 x T8 18 39 0.17 45 ... 140 0.97 16 74 ENEC 2 x T8 30 58 0.26 45 ... 140 0.97 30 74 BCD36.2F-01/ 220-240/1-10V 10097194 2 x T8 36 74 0.31 40 ... 110 0.97 32 74 ENEC 2 x TC-F 36 74 0.31 40 ... 110 0.97 32 74 ENEC BCD58.2F-01/ 220-240/1-10V 10097195 2 x TC-L 36 74 0.31 40 ... 110 0.97 32 74 ENEC 2 x TC-L 40 89 0.38 40 ... 110 0.97 40 74 ENEC 2 x T8 58 110 0.48 40 ... 145 0.97 58 74 ENEC Dimensions | weights | temperatures Short designation Length X Width Y Height Z Hole spacing XM (length direction) mm mm mm mm mm BCD55.1F-01 360 30 21 350 BCD55.2F-01 425 30 21 BCD18.1F-01 360 30 21 BCD36.1F-01 360 30 BCD58.1F-01 360 BCD18.3-4F-01 Hole spacing ZM (height direction) Diagram Weight Ambient temperature ta Housing temperature tc,max kg °C °C 9 M 0.250 5 ... 55 70 415 9 M 0.355 5 ... 55 70 350 9 M 0.246 5 ... 55 70 21 350 9 M 0.250 5 ... 55 70 30 21 350 9 M 0.260 5 ... 55 70 360 39 21 350 9 M 0.310 5 ... 60 75 BCD18.2F-01 425 30 21 415 9 M 0.325 5 ... 55 70 BCD36.2F-01 425 30 21 415 9 M 0.328 5 ... 55 75 BCD58.2F-01 425 30 21 415 9 M 0.330 5 ... 55 75 Control gear for FL Designation Electronic control gears (dimmable) | BCD T8 1-10V Operating data Case drawing Y Z Zm M Xm X BAG electronics | Product Catalogue 2014 131 Wiring diagrams 64 1 2 3 4 1−10 V 74 1−10 V Electronic control gears (dimmable) | BCD T8 1-10V Control gear for FL 132 1 2 3 4 5 6 7 76 17 16 15 14 n.c. 1 2 3 4 5 6 7 + 1-10V – 77 17 16 15 14 n.c. 1 2 3 4 5 6 7 + 1-10V – Product Catalogue 2014 | BAG electronics BAG electronics | Product Catalogue 2014 133 Control gear for FL Electronic control gears (dimmable) | BCD T8 1-10V BCS TC Non-dimmable electronic control gear for CFL, T5 and T8 lamps Electronic control gears (non-dimmable) | BCS TC Product information • All models in compact housing for space-saving application in luminaires • Multi-Power technology for operation of different lamps and wattages on the same ECG Control gear for FL • Electrode preserving warm start for maximum lamp life, even at increased switching frequency; starting time < 1.5 s • Cut-Off technology: minimised heat current through electrodes during operation, for optimum light output and reduced power loss. • Safety switch-off in case of abnormal lamp operation, e. g. defective electrode and end of lamp life; tested acc. to EN 61347-2-3 + Test 2 • Suitable for direct current operation and emergency lighting installations; complies with requirements for emergency lighting according to EN 61347- 2-3/J • Constant lamp output independent of mains voltage fluctuations • Optimum ignition safety even at low temperatures: automatic second start if necessary • Automatic restart after lamp replacement • Suitable for direct current operation and emergency lighting installations; complies with requirements for emergency lighting according to EN 61347- 2-3/J • Quick restart of lamps after short power disruptions • Connecting earth can be disregarded in suitable luminaires with safety classification II • Energy efficiency EEI=A2 • Nominal service life: 50.000 h with failure rate of ≤ 10% and operation at tc=tc,max 134 Product Catalogue 2014 | BAG electronics Industry Office & Commercial Outdoor Shop Technical data Conformity EN 61347-1 Mains voltage supply Rated voltage range 220 ... 240 [V] EN 61347-2-3 Rated frequency 0 / 50 ... 60 [Hz] EN 61347-2-3/C Admissible continuous voltage range (AC) 198 - 264 [V] EN 60929 EN 61 00-3-2 Battery operation Voltage range continuous DC 198 VDC - 278 VDC Voltage short time DC min. 176 VDC Overvoltage protection (time) 350 V / 2 h Max. leakage current 0.5 mA EN 6100-3-3 EN 61547 EN 55015 Designations Operating data Lamp designation System rating Input current Operation frequency Power factor Rated power lamps Picture reference Approval for lamps W W A kHz BCS28.1Q-01/220-240 10097436 1 x TC-DD 28 28 0.12 45 0.97 28 11 ENEC BCS38.1Q-01/220-240 10097437 1 x TC-DD 38 38 0.17 42 0.98 38 11 ENEC 1 x TC-F 36 37 0.16 42 0.98 32 11 ENEC 1 x TC-L 36 37 0.16 42 0.98 32 11 ENEC BCS55.1Q-01/220-240/ 10097439 1 x TC-DD 55 58 0.25 45 0.95 55 11 ENEC BCS18.1Q-01/220-240 10097534 1 x TC-DEL 18 18 0.08 45 0.95 16 11 ENEC, EMV 1 x TC-TEL 18 18 0.08 45 0.95 16 11 ENEC, EMV BCS42.1Q-01/220-240 10097535 1 x T12 40 42 0.19 45 0.96 40 11 - 1 x T5C 22 24 0.11 45 0.96 22 11 ENEC, EMV 1 x T5C 40 42 0.19 45 0.96 40 11 ENEC, EMV 1 x T5 24 27 0.12 45 0.96 24 11 - 1 x T5 39 38 0.17 45 0.96 39 11 - 1 x T8 15 18 0.08 45 0.96 14 11 - 1 x T8 18 19 0.09 45 0.96 16 11 - 1 x T8 36 35 0.16 45 0.96 32 11 - 1 x T8 38 37 0.17 45 0.96 32 11 - 1 x TC-DEL 26 27 0.12 45 0.96 24 11 ENEC, EMV 1 x TC-F 18 18 0.08 45 0.96 16 11 ENEC, EMV 1 x TC-F 24 24 0.11 45 0.96 22 11 ENEC, EMV 1 x TC-F 36 35 0.16 45 0.96 32 11 ENEC, EMV 1 x TC-L 18 18 0.08 45 0.96 16 11 ENEC, EMV 1 x TC-L 24 24 0.11 45 0.96 22 11 ENEC, EMV 1 x TC-L 36 35 0.16 45 0.96 32 11 ENEC, EMV 1 x TC-L 40 42 0.19 45 0.96 40 11 ENEC, EMV 1 x TC-TEL 26 27 0.12 45 0.96 24 11 ENEC, EMV 1 x TC-TEL 32 35 0.16 45 0.96 32 11 ENEC, EMV 1 x TC-TEL 42 46 0.21 45 0.96 42 11 ENEC, EMV BCS55.1Q-01/220-240/T5C 10097634 1 x T5C 55 59 0.26 45 0.98 55 11 ENEC, EMV 1 x TC-L 55 59 0.26 45 0.98 55 11 ENEC, EMV BCS60.1Q-01/220-240 10097635 1 x T5C 60 64 0.28 48 0.98 60 11 ENEC, EMV SCS42.1Q-01/220-240/4kV 166772 1 x TC-DEL 26 27 0.12 45 0.94 24 11 ENEC, EMV 1 x TC-F 18 19 0.11 45 0.87 16 11 VDE, EMV 1 x TC-F 24 25 0.11 45 0.92 22 11 VDE, EMV 1 x TC-L 18 19 0.11 45 0.87 16 11 VDE, EMV 1 x TC-L 24 25 0.11 45 0.92 22 11 VDE, EMV 1 x TC-TEL 26 27 0.12 45 0.94 24 11 ENEC, EMV 1 x TC-TEL 32 36 0.16 45 0.96 32 11 ENEC, EMV 1 x TC-TEL 42 46 0.20 45 0.98 42 11 ENEC, EMV Electronic control gears (non-dimmable) | BCS TC Material number Control gear for FL Designation Dimensions | weights | temperatures Short designation Length X Width Y Height Z Hole spacing XM (length direction) Hole spacing YM (width direction) Hole spacing ZM (height direction) Diagram Weight Ambient temperature ta Housing temperature tc,max °C mm mm mm mm mm mm kg °C BCS28.1Q-01 103 67 30 94 57 28 G 0.118 -20 ... 60 75 BCS38.1Q-01 103 67 30 94 57 28 G 0.118 -20 ... 60 75 BCS55.1Q-01 103 67 30 94 57 28 G 0.118 -20 ... 50 75 BCS18.1Q-01 103 67 30 94 57 28 G 0.112 -20 ... 60 75 BCS42.1Q-01 103 67 30 94 57 28 G 0.112 -20 ... 60 75 BCS60.1Q-01 103 67 30 94 57 28 G 0.146 -20 ... 50 70 SCS42.1Q-01 103 67 31 94 57 28 G 0.145 -20 ... 55 80 Case drawing 11 ZM Z X1 YM Y G Wiring diagrams XM X 1 2 3 4 BAG electronics | Product Catalogue 2014 135 BCS TC Twingle Non-dimmable electronic control gear for CFL, T5 and T8 lamps with TwingleTechnology Electronic control gears (non-dimmable) | BCS TC Twingle Product information • All models in compact housing for space-saving application in luminaires • Multi-Power technology for operation of different lamps and wattages on the same ECG • Twingle function: operation with 1 or 2 lamps Control gear for FL • Electrode preserving warm start for maximum lamp life, even at increased switching frequency; starting time < 1.5 s • Cut-Off technology: minimised heat current through electrodes during operation, for optimum light output and reduced power loss. • Safety switch-off in case of abnormal lamp operation, e. g. defective electrode and end of lamp life; tested acc. to EN 61347-2-3 + Test 2 • Constant lamp output independent of mains voltage fluctuations • Optimum ignition safety even at low temperatures: automatic second start if necessary • Automatic restart after lamp replacement • Suitable for direct current operation and emergency lighting installations; complies with requirements for emergency lighting according to EN 61347- 2-3/J • Quick restart of lamps after short power disruptions • Connecting earth can be disregarded in suitable luminaires with safety classification II • Energy efficiency EEI=A2 • Nominal service life: 50.000 h with failure rate of ≤ 10% and operation at tc=tc,max 136 Product Catalogue 2014 | BAG electronics Industry Office & Commercial Outdoor Shop Technical data Conformity EN 61347-1 Mains voltage supply Rated voltage range 220 ... 240 [V] EN 61347-2-3 Rated frequency 0 / 50 ... 60 [Hz] EN 61347-2-3/C Admissible continuous voltage range (AC) 198 - 264 [V] EN 60929 EN 61 00-3-2 Battery operation Voltage range continuous DC 198 VDC - 278 VDC Voltage short time DC min. 176 VDC Overvoltage protection (time) 350 V / 2 h Max. leakage current 0.5 mA EN 6100-3-3 EN 61547 EN 55015 Designations Operating data Lamp designation W W A kHz BCS21.1-2Q-01/220-240 10097543 1 x T5 14 15 0.07 50 0.9 14 31 - 1 x T5 21 22 0.10 50 0.9 21 31 - BCS18.1-2Q-01/220-240 10097544 BCS42.1/26.2Q-01/220-240 10097545 BCS70.1/42.2Q-01/220-240 10097546 System rating Input current Operation frequency Power factor Rated power lamps Picture reference Approval for lamps 1 x TC-DD 10 12 0.05 50 0.9 10 31 - 1 x TC-DD 16 17 0.07 50 0.9 16 31 - 1 x TC-DEL 10 12 0.05 50 0.9 10 31 ENEC 1 x TC-DEL 13 14 0.07 50 0.9 13 31 ENEC 1 x TC-SE 9 11 0.05 50 0.9 9 31 ENEC 1 x TC-SE 11 13 0.06 50 0.9 11 31 ENEC 1 x TC-TEL 13 14 0.07 50 0.9 13 31 ENEC 2 x T5 14 28 0.13 50 0.9 14 31 - 2 x TC-DD 10 21 0.10 50 0.9 10 31 - 2 x TC-DD 16 29 0.14 50 0.9 16 31 - 2 x TC-DEL 10 21 0.10 50 0.9 10 31 ENEC 2 x TC-DEL 13 27 0.13 50 0.9 13 31 ENEC 2 x TC-SE 9 20 0.09 50 0.9 9 31 ENEC 2 x TC-SE 11 25 0.12 50 0.9 11 31 ENEC 2 x TC-TEL 13 27 0.13 50 0.9 13 31 ENEC 1 x TC-DEL 18 19 0.08 41 0.95 16 31 ENEC, EMV 1 x TC-TEL 18 19 0.08 41 0.95 16 31 ENEC, EMV 2 x TC-DEL 18 37 0.17 41 0.95 16 31 ENEC, EMV 2 x TC-TEL 18 37 0.17 41 0.95 16 31 ENEC, EMV 1 x T12 40 37 0.17 45 0.95 40 31 - 1 x T5C 22 24 0.11 45 0.95 22 31 ENEC, EMV 1 x T5C 40 42 0.19 45 0.95 40 31 ENEC, EMV 1 x T5 24 26 0.12 45 0.95 24 31 - 1 x T5 39 40 0.17 45 0.95 39 31 - 1 x T8 15 17 0.08 45 0.95 14 31 - 1 x T8 18 19 0.09 45 0.95 16 31 - 1 x T8 36 36 0.16 45 0.95 32 31 - 1 x T8 38 37 0.17 45 0.95 32 31 - 1 x TC-DEL 26 26 0.12 45 0.95 24 31 ENEC, EMV 1 x TC-F 18 18 0.08 45 0.95 16 31 ENEC, EMV 1 x TC-F 24 24 0.11 45 0.95 22 31 ENEC, EMV 1 x TC-L 18 18 0.08 45 0.95 16 31 ENEC, EMV 1 x TC-L 24 24 0.11 45 0.95 22 31 ENEC, EMV 1 x TC-L 40 42 0.19 45 0.95 40 31 ENEC, EMV 1 x TC-TEL 26 26 0.12 45 0.95 24 31 ENEC, EMV 1 x TC-TEL 32 35 0.16 45 0.95 32 31 ENEC, EMV 1 x TC-TEL 42 45 0.21 45 0.95 42 31 ENEC, EMV 2 x T5C 22 48 0.22 45 0.95 22 31 ENEC, EMV 2 x T5 24 52 0.24 45 0.95 24 31 - 2 x T8 15 33 0.15 45 0.95 14 31 - 2 x T8 18 38 0.16 45 0.95 16 31 - 2 x TC-DEL 26 52 0.24 45 0.95 24 31 ENEC, EMV 2 x TC-F 18 36 0.16 45 0.95 16 31 ENEC, EMV 2 x TC-F 24 48 0.22 45 0.95 22 31 ENEC, EMV 2 x TC-L 18 36 0.16 45 0.95 16 31 ENEC, EMV 2 x TC-L 24 48 0.22 45 0.95 22 31 ENEC, EMV 2 x TC-TEL 26 52 0.24 45 0.95 24 31 ENEC, EMV 1 x TC-DEL 26 27 0.13 45 0.95 24 31 ENEC 1 x TC-TEL 26 27 0.13 45 0.95 24 31 ENEC 1 x TC-TEL 32 35 0.16 45 0.95 32 31 ENEC 1 x TC-TEL 42 47 0.21 45 0.95 42 31 ENEC 1 x TC-TEL 57 61 0.27 45 0.95 57 31 ENEC 1 x TC-TEL 70 75 0.33 45 0.95 70 31 ENEC 2 x T5C 22 49 0.22 45 0.95 22 31 ENEC 2 x T5C 40/22 68 0.30 45 0.95 22 31 ENEC 2 x TC-DEL 26 53 0.24 45 0.95 24 31 ENEC 2 x TC-TEL 26 53 0.24 45 0.95 24 31 ENEC 2 x TC-TEL 32 71 0.31 45 0.95 32 31 ENEC 2 x TC-TEL 42 94 0.42 45 0.95 42 31 ENEC BAG electronics | Product Catalogue 2014 Electronic control gears (non-dimmable) | BCS TC Twingle Material number Control gear for FL Designation 137 Dimensions | weights | temperatures Short designation Length X Width Y Hole spacing XM (length direction) Hole spacing YM (width direction) Hole spacing ZM (height direction) Diagram Weight Ambient temperature ta Housing temperature tc,max °C mm mm mm mm mm mm kg °C BCS21.1-2Q-01 103 67 30 94 57 28 G 0.126 -20 ... 60 75 BCS18.1-2Q-01 103 67 30 94 57 28 G 0.128 -20 ... 60 75 BCS42.1 / 26.2Q-01 103 67 30 94 57 28 G 0.135 -20 ... 60 75 BCS70.1 / 42.2Q-01 103 67 30 94 57 28 G 0.150 -20 ... 50 80 Case drawing G Electronic control gears (non-dimmable) | BCS TC Twingle YM Y ZM Z X1 XM X Wiring diagrams 31 1 2 3 4 5 6 Control gear for FL 138 Height Z Product Catalogue 2014 | BAG electronics BAG electronics | Product Catalogue 2014 139 Control gear for FL Electronic control gears (non-dimmable) | BCS TC Twingle BCS TC Twingle Independent Non-dimmable electronic control gear for CFL, T5 and T8 lamps with TwingleTechnology in independent housing Electronic control gears (non-dimmable) | BCS TC Twingle Independent Product information • Housing with integrated strain relief and terminal cover, separate for mains power supply and lamp connection • Plug-in positions for standard terminal blocks designed for easy feed through • Multi-Power technology for operation of different lamps and wattages on the same ECG Control gear for FL • Twingle function: operation with 1 or 2 lamps • Electrode preserving warm start for maximum lamp life, even at increased switching frequency; starting time < 1.5 s • Cut-Off technology: minimised heat current through electrodes during operation, for optimum light output and reduced power loss. • Safety switch-off in case of abnormal lamp operation, e. g. defective electrode and end of lamp life; tested acc. to EN 61347-2-3 + Test 2 • Constant lamp output independent of mains voltage fluctuations • Optimum ignition safety even at low temperatures: automatic second start if necessary • Automatic restart after lamp replacement • Suitable for direct current operation and emergency lighting installations; complies with requirements for emergency lighting according to EN 61347- 2-3/J • Quick restart of lamps after short power disruptions • Connecting earth can be disregarded in suitable luminaires with safety classification II • Energy efficiency EEI=A2 • Nominal service life: 50.000 h with failure rate of ≤ 10% and operation at tc=tc,max 140 Product Catalogue 2014 | BAG electronics Industry Office & Commercial Outdoor Shop Technical data Conformity EN 61347-1 Mains voltage supply Rated voltage range 220 ... 240 [V] EN 61347-2-3 Rated frequency 0 / 50 ... 60 [Hz] EN 61347-2-3/C Admissible continuous voltage range (AC) 198 - 264 [V] EN 60929 EN 61 00-3-2 Battery operation Voltage range continuous DC 198 VDC - 278 VDC Voltage short time DC min. 176 VDC Overvoltage protection (time) 350 V / 2 h Max. leakage current 0.5 mA EN 6100-3-3 EN 61547 EN 55015 Designations Operating data Lamp designation W W A kHz BCS21.1-2QI-01/220-240 10095743 1 x T5 14 15 0.07 50 0.9 14 31 - 1 x T5 21 22 0.10 50 0.9 21 31 - BCS18.1-2QI-01/220-240 BCS42.1/26.2QI-01/ 220-240 10095744 10095745 System rating Input current Operation frequency Power factor Rated power lamps Picture reference Approval for lamps 1 x TC-DD 10 15 0.06 50 0.9 10 31 - 1 x TC-DD 16 17 0.07 50 0.9 16 31 - 1 x TC-DEL 10 12 0.06 50 0.9 10 31 ENEC 1 x TC-DEL 13 14 0.06 50 0.9 13 31 ENEC 1 x TC-SE 9 11 0.05 50 0.9 9 31 ENEC 1 x TC-SE 11 13 0.06 50 0.9 11 31 ENEC 1 x TC-TEL 13 14 0.06 50 0.9 13 31 ENEC 2 x T5 14 28 0.13 50 0.9 14 31 - 2 x TC-DD 10 21 0.10 50 0.9 10 31 - 2 x TC-DD 16 29 0.14 50 0.9 16 31 - 2 x TC-DEL 10 21 0.10 50 0.9 10 31 ENEC 2 x TC-DEL 13 27 0.13 50 0.9 13 31 ENEC 2 x TC-SE 9 20 0.09 50 0.9 9 31 ENEC 2 x TC-SE 11 25 0.12 50 0.9 11 31 ENEC 2 x TC-TEL 13 27 0.13 50 0.9 13 31 ENEC 1 x TC-DEL 18 19 0.08 50 0.95 16 31 ENEC 1 x TC-TEL 18 19 0.08 50 0.95 16 31 ENEC 2 x TC-DEL 18 37 0.17 50 0.95 16 31 ENEC 2 x TC-TEL 18 37 0.17 50 0.95 16 31 ENEC 1 x T12 40 37 0.17 45 0.95 40 31 - 1 x T5C 22 24 0.11 45 0.95 22 31 ENEC 1 x T5C 40 42 0.19 45 0.95 40 31 ENEC 1 x T5 24 26 0.12 45 0.95 24 31 - 1 x T5 39 40 0.17 45 0.95 39 31 - 1 x T8 15 17 0.08 45 0.95 14 31 - 1 x T8 18 19 0.09 45 0.95 16 31 - 1 x T8 36 36 0.16 45 0.95 32 31 - 1 x T8 38 37 0.17 45 0.95 32 31 - 1 x TC-DEL 26 26 0.12 45 0.95 24 31 ENEC 1 x TC-F 18 18 0.08 45 0.95 16 31 ENEC 1 x TC-F 24 24 0.11 45 0.95 22 31 ENEC 1 x TC-L 18 18 0.08 45 0.95 16 31 ENEC 1 x TC-L 24 24 0.11 45 0.95 22 31 ENEC 1 x TC-L 40 42 0.19 45 0.95 40 31 ENEC 1 x TC-TEL 26 26 0.12 45 0.95 24 31 ENEC 1 x TC-TEL 32 35 0.16 45 0.95 32 31 ENEC 1 x TC-TEL 42 45 0.21 45 0.95 42 31 ENEC 2 x T5C 22 48 0.22 45 0.95 22 31 ENEC 2 x T5 24 52 0.24 45 0.95 24 31 - 2 x T8 15 33 0.15 45 0.95 14 31 - 2 x T8 18 35 0.16 45 0.95 16 31 - 2 x TC-DEL 26 52 0.24 45 0.95 24 31 ENEC 2 x TC-F 18 36 0.16 45 0.95 16 31 ENEC 2 x TC-F 24 48 0.22 45 0.95 22 31 ENEC 2 x TC-L 18 36 0.16 45 0.95 16 31 ENEC 2 x TC-L 24 48 0.22 45 0.95 22 31 ENEC 2 x TC-TEL 26 52 0.24 45 0.95 24 31 ENEC Electronic control gears (non-dimmable) | BCS TC Twingle Independent Material number Control gear for FL Designation Dimensions | weights | temperatures Short designation Length X Width Y Height Z Hole spacing XM (length direction) Diagram Weight Ambient temperature ta Housing temperature tc,max mm mm mm mm BCS21.1-2QI-01 180 86 33 191 R kg °C °C 0.190 -20 ... 60 BCS18.1-2QI-01 180 86 33 191 75 R 0.190 -20 ... 60 BCS42.1 / 26.2QI-01 180 86 33 191 75 R 0.195 -20 ... 60 75 BAG electronics | Product Catalogue 2014 141 Control gear for FL Product Catalogue 2014 | BAG electronics 142 Wiring diagrams 31 1 2 3 4 5 6 Z Electronic control gears (non-dimmable) | BCS TC Twingle Independent Y Y Z Case drawing R X XM BAG electronics | Product Catalogue 2014 143 Control gear for FL Electronic control gears (non-dimmable) | BCS TC Twingle Independent BCS TC Linear Non-dimmable electronic control gear for CFL, T5 and T8 lamps Electronic control gears (non-dimmable) | BCS TC Linear Product information • Alternative housing to conventional control gear • Multi-Power technology for operation of different lamps and wattages on the same ECG • Twingle function: operation with 1 or 2 lamps Control gear for FL • Electrode preserving warm start for maximum lamp life, even at increased switching frequency; starting time < 1.5 s • Cut-Off technology: minimised heat current through electrodes during operation, for optimum light output and reduced power loss. • Safety switch-off in case of abnormal lamp operation, e. g. defective electrode and end of lamp life; tested acc. to EN 61347-2-3 + Test 2 • Flimmer free light through high frequency lamp operation, no stroboscope effect • Constant lamp output independent of mains voltage fluctuations • Optimum ignition safety even at low temperatures: automatic second start if necessary • Automatic restart after lamp replacement • Suitable for direct current operation and emergency lighting installations; complies with requirements for emergency lighting according to EN 61347- 2-3/J • Quick restart of lamps after short power disruptions • Connecting earth can be disregarded in suitable luminaires with safety classification II • Energy efficiency EEI=A2 • Nominal service life: 50.000 h with failure rate of ≤ 10% and operation at tc=tc,max 144 Product Catalogue 2014 | BAG electronics Industry Office & Commercial Outdoor Shop Technical data Conformity EN 61347-1 Mains voltage supply Rated voltage range 220 ... 240 [V] EN 61347-2-3 Rated frequency 0 / 50 ... 60 [Hz] EN 61347-2-3/C Admissible continuous voltage range (AC) 198 - 264 [V] EN 60929 EN 61 00-3-2 Battery operation Voltage range continuous DC 198 VDC - 278 VDC Voltage short time DC min. 176 VDC Overvoltage protection (time) 350 V / 2 h Max. leakage current 0.5 mA EN 6100-3-3 EN 61547 EN 55015 Designations Operating data Lamp designation W W A kHz BCS21.1-2LS-01/220-240 10095043 1 x T5 14 15 0.07 50 0.9 14 91 - 1 x T5 21 22 0.10 50 0.9 21 91 - BCS18.1-2LS-01/220-240 10095044 BCS42.1/26.2LS-01/220-240 10095045 System rating Input current Operation frequency Power factor Rated power lamps Picture reference Approval for lamps 1 x TC-DD 10 15 0.06 50 0.9 10 91 - 1 x TC-DD 16 17 0.07 50 0.9 16 91 - 1 x TC-DEL 10 12 0.05 50 0.9 10 91 ENEC 1 x TC-DEL 13 14 0.07 50 0.9 13 91 ENEC 1 x TC-SE 9 11 0.05 50 0.9 9 91 ENEC 1 x TC-SE 11 13 0.06 50 0.9 11 91 ENEC 1 x TC-TEL 13 14 0.07 50 0.9 13 91 ENEC 2 x T5 14 28 0.13 50 0.9 14 91 - 2 x TC-DD 10 21 0.10 50 0.9 10 91 - 2 x TC-DD 16 29 0.14 50 0.9 16 91 - 2 x TC-DEL 10 21 0.10 50 0.9 10 91 ENEC 2 x TC-DEL 13 27 0.13 50 0.9 13 91 ENEC 2 x TC-SE 9 20 0.09 50 0.9 9 91 ENEC 2 x TC-SE 11 25 0.12 50 0.9 11 91 ENEC 2 x TC-TEL 13 27 0.13 50 0.9 13 91 ENEC 1 x TC-DEL 18 19 0.08 41 0.95 16 91 ENEC 1 x TC-TEL 18 19 0.08 41 0.95 16 91 ENEC 2 x TC-DEL 18 37 0.17 41 0.95 16 91 ENEC 2 x TC-TEL 18 37 0.17 41 0.95 16 91 ENEC 1 x T12 40 37 0.17 45 0.95 40 91 - 1 x T5C 22 24 0.11 45 0.95 22 91 ENEC 1 x T5C 40 42 0.19 45 0.95 40 91 ENEC 1 x T5 24 26 0.12 45 0.95 24 91 - 1 x T5 39 40 0.17 45 0.95 39 91 - 1 x T8 15 17 0.08 45 0.95 14 91 - 1 x T8 18 19 0.09 45 0.95 16 91 - 1 x T8 36 36 0.16 45 0.95 32 91 - 1 x T8 38 37 0.17 45 0.95 32 91 - 1 x TC-DEL 26 26 0.12 45 0.95 24 91 ENEC 1 x TC-F 18 18 0.08 45 0.95 16 91 ENEC 1 x TC-F 24 24 0.11 45 0.95 22 91 ENEC 1 x TC-L 18 18 0.08 45 0.95 16 91 ENEC 1 x TC-L 24 24 0.11 45 0.95 22 91 ENEC 1 x TC-L 40 42 0.19 45 0.95 40 91 ENEC 1 x TC-TEL 26 26 0.12 45 0.95 24 91 ENEC 1 x TC-TEL 32 35 0.16 45 0.95 32 91 ENEC 1 x TC-TEL 42 45 0.21 45 0.95 42 91 ENEC 2 x T5C 22 48 0.22 45 0.95 22 91 ENEC 2 x T5 24 52 0.24 45 0.95 24 91 - 2 x T8 15 33 0.15 45 0.95 14 91 - 2 x T8 18 35 0.16 45 0.95 16 91 - 2 x TC-DEL 26 52 0.24 45 0.95 24 91 ENEC 2 x TC-F 18 36 0.16 45 0.95 16 91 ENEC 2 x TC-F 24 48 0.22 45 0.95 22 91 ENEC 2 x TC-L 18 36 0.16 45 0.95 16 91 ENEC 2 x TC-L 24 48 0.22 45 0.95 22 91 ENEC 2 x TC-TEL 26 52 0.24 45 0.95 24 91 ENEC BCS28.1LS-01/220-240 10097426 1 x T8 30 30 0.13 45 0.97 30 13 - 1 x TC-DD 28 28 0.12 45 0.97 28 13 ENEC BCS38.1LS-01/220-240 10097427 1 x T8 36 35 0.15 42 0.98 32 13 ENEC 1 x TC-DD 38 38 0.17 42 0.98 38 13 ENEC 1 x TC-F 36 36 0.16 42 0.98 32 13 ENEC 1 x TC-L 36 36 0.16 42 0.98 32 13 ENEC BAG electronics | Product Catalogue 2014 Electronic control gears (non-dimmable) | BCS TC Linear Material number Control gear for FL Designation 145 Dimensions | weights | temperatures Short designation Length X Width Y mm mm mm mm BCS21.1-2LS-01 150 42 30 140 Q BCS18.1-2LS-01 150 42 30 140 BCS42.1 / 26.2LS-01 150 42 30 BCS28.1LS-01 150 42 BCS38.1LS-01 150 42 Case drawing Electronic control gears (non-dimmable) | BCS TC Linear Control gear for FL 146 Y Z Q XM X Wiring diagrams 13 1 2 3 4 5 6 91 1 2 3 4 5 6 Product Catalogue 2014 | BAG electronics Height Z Hole spacing XM (length direction) Diagram Weight Ambient temperature ta Housing temperature tc,max kg °C °C 0.121 -20 ... 60 75 Q 0.121 -20 ... 60 75 140 Q 0.119 -20 ... 60 75 30 140 Q 0.119 -20 ... 60 70 30 140 Q 0.119 -20 ... 60 70 BAG electronics | Product Catalogue 2014 147 Control gear for FL Electronic control gears (non-dimmable) | BCS TC Linear EBS MINIPOWER Non-dimmable electronic control gear for T5, T8 and CFL lamps Electronic control gears (non-dimmable) | EBS MINIPOWER Product information • Electronic control gear for system ratings ≤ 25 W in small housing • Electrode preserving warm start for maximum lamp life,starting time < 1.2 s • Multi-Power technology for operation of different lamps and wattages on the same ECG Control gear for FL • Safety switch-off in case of abnormal lamp operation, e. g. defective electrode and end of lamp life; tested acc. to EN 61347-2-3 • Flimmer free light through high frequency lamp operation, no stroboscope effect • Automatic restart after lamp replacement • Certified as thermally protected control gear, e.g. for application in luminaires • Suitable for constant current operation and use in emergency lighting installations • Suitable for luminaires in protection class II • Energy efficiency EEI=A2 • Nominal service life: 40.000 h with a failure rate of ≤ 10% and operation at tc=tc,max 148 Product Catalogue 2014 | BAG electronics Industry Office & Commercial Outdoor Shop Technical data Conformity EN 61347-1 Mains voltage supply Rated voltage range 220 ... 240 [V] EN 61347-2-3 Rated frequency 0 / 50 ... 60 [Hz] EN 61347-2-3/C Admissible continuous voltage range (AC) 198 - 264 [V] EN 60929 EN 61 00-3-2 Battery operation Voltage range continuous DC 198 VDC - 278 VDC Voltage short time DC min. 176 VDC Overvoltage protection (time) 320V / 2 h, 320V / Max. leakage current 0.5 mA EN 6100-3-3 EN 61547 EN 55015 Designations Operating data Lamp designation W W A kHz EBS16.1C-01/220-240 10050989 1 x T5 4 7 0.05 45 0.53 4 9 - 1 x T5 6 6.9 0.06 40 0.5 6 9 VDE, EMV EBS21.1C-01/220-240 EBS26.1C-01/220-240 EBS16.1M-01/220-240 EBS21.1M-01/220-240 EBS26.1M-01/220-240 10050990 10050992 10050993 10050994 10050996 System rating Input current Operation frequency Power factor Rated power lamps Picture reference Approval for lamps 1 x T5 8 9 0.07 40 0.5 8 9 VDE, EMV 1 x T5 13 15 0.09 40 0.5 13 9 VDE, EMV 1 x T8 16 15 0.10 40 0.5 16 9 VDE, EMV 1 x TC-DD 10 12 0.08 40 0.5 10 9 VDE, EMV 1 x TC-DD 16 14 0.10 40 0.5 16 9 VDE, EMV 1 x TC-DEL 10 12 0.08 40 0.5 10 9 VDE, EMV 1 x TC-SE 5 7 0.05 45 0.53 5 9 VDE, EMV 1 x TC-SE 7 8 0.06 40 0.5 7 9 VDE, EMV 1 x TC-SE 9 10 0.07 40 0.5 9 9 VDE, EMV 1 x TC-SE 11 12 0.09 40 0.5 11 9 VDE, EMV 1 x TC-DEL 18 17 0.13 40 0.55 16 9 VDE, EMV 1 x TC-TEL 13 14 0.12 40 0.55 13 9 VDE, EMV 1 x TC-TEL 18 17 0.13 40 0.55 16 9 VDE, EMV 1 x TC-DEL 13 14 0.12 40 0.55 13 9 VDE, EMV 1 x T5C 22 21 0.15 40 0.55 22 9 VDE, EMV 1 x T5 24 24 0.18 40 0.55 24 9 VDE, EMV 1 x T8 15 17 0.12 45 0.55 14 9 VDE, EMV 1 x T8 18 16 0.13 40 0.55 16 9 VDE, EMV 1 x TC-DEL 26 25 0.18 40 0.55 24 9 VDE, EMV 1 x TC-F 18 16 0.13 40 0.55 16 9 VDE, EMV 1 x TC-F 24 24 0.17 40 0.55 22 9 VDE, EMV 1 x TC-L 24 24 0.17 40 0.55 22 9 VDE, EMV 1 x TC-TEL 26 25 0.18 40 0.55 24 9 VDE, EMV 1 x T5 6 6.9 0.06 40 0.5 6 9 VDE, EMV 1 x T5 8 9 0.07 40 0.5 8 9 VDE, EMV 1 x T5 13 15 0.09 40 0.5 13 9 VDE, EMV 1 x T8 16 15 0.10 40 0.5 16 9 VDE, EMV 1 x TC-DD 16 14 0.10 40 0.5 16 9 VDE, EMV 1 x TC-DEL 10 12 0.08 40 0.5 10 9 VDE, EMV 1 x TC-SE 7 8 0.06 40 0.5 7 9 VDE, EMV 1 x TC-SE 9 10 0.07 40 0.5 9 9 VDE, EMV 1 x TC-SE 11 12 0.09 40 0.5 11 9 VDE, EMV 1 x T5 14 17 0.12 40 0.55 14 9 VDE, EMV 1 x T5 21 22 0.16 40 0.55 21 9 VDE, EMV 1 x TC-DEL 13 14 0.12 40 0.55 13 9 VDE, EMV 1 x TC-TEL 13 14 0.12 40 0.55 13 9 VDE, EMV 1 x TC-DEL 18 17 0.13 40 0.55 16 9 VDE, EMV 1 x TC-TEL 18 17 0.13 40 0.55 16 9 VDE, EMV 1 x T5C 22 21 0.15 40 0.55 22 9 VDE, EMV 1 x T5 24 24 0.18 40 0.55 24 9 VDE, EMV 1 x T8 18 16 0.13 40 0.55 16 9 VDE, EMV 1 x TC-F 18 16 0.13 40 0.55 16 9 VDE, EMV VDE, EMV 1 x TC-L 24 24 0.17 40 0.55 22 9 1 x TC-F 24 24 0.17 40 0.55 22 9 VDE, EMV 1 x TC-DEL 26 25 0.18 40 0.55 24 9 VDE, EMV 1 x TC-TEL 26 25 0.18 40 0.55 24 9 VDE, EMV BAG electronics | Product Catalogue 2014 Electronic control gears (non-dimmable) | EBS MINIPOWER Materialnumber Control gear for FL Designation 149 Dimensions | weights | temperatures Short designation Length X Width Y Height Z Weight Ambient temperature ta Housing temperature tc,max mm mm mm mm EBS16.1C-01 80 42 20 70 P kg °C °C 0.053 -20 ... 55 EBS21.1C-01 80 42 20 70 75 P 0.053 -20 ... 55 EBS26.1C-01 80 42 20 80 70 P 0.053 -20 ... 55 EBS16.1M-01 150 22 80 19 140 F 0.050 -20 ... 55 EBS21.1M-01 150 75 22 19 140 F 0.050 -20 ... 55 EBS26.1M-01 150 75 22 19 - F 0.050 -20 ... 55 80 Case drawing Diagram Wiring diagrams F Y Z 9 XM X Z P Y Electronic control gears (non-dimmable) | EBS MINIPOWER XM X Control gear for FL 150 Hole spacing XM (length direction) Product Catalogue 2014 | BAG electronics 1 2 3 4 BAG electronics | Product Catalogue 2014 151 Control gear for FL Electronic control gears (non-dimmable) | EBS MINIPOWER BCD TC DALI DALI dimmable electronic control gear for CFL, T5 and T8 lamps with Twingle-Technology Electronic control gears (dimmable) | BCD TC DALI Product information • Dim interface: DALI/Push-Dim • Dim range 3...100% luminous flux • Multi-Power technology for operation of different lamps and wattages on the same ECG • Twingle function: operation with 1 or 2 lamps • Suitable for dimming amalgam lamps Control gear for FL • Electrode preserving warm start for maximum lamp life, even at increased switching frequency; starting time < 1.5 s • Cut-Off technology at 100% luminous flux: minimised heat current through electrodes during operation, for optimum light output and reduced power • Safety switch-off in case of abnormal lamp operation, e. g. defective electrode and end of lamp life; tested acc. to EN 61347-2-3 + Test 2 Industry Office & Commercial Outdoor Shop Technical data Conformity EN 61347-1 Mains voltage supply Rated voltage range 220 ... 240 [V] EN 61347-2-3 Rated frequency 0 / 50 ... 60 [Hz] EN 61347-2-3/C Admissible continuous voltage range (AC) 198 - 264 [V] EN 60929 EN 62386-102 Battery operation Voltage range continuous DC 198 VDC - 278 VDC Voltage short time DC min. 176 VDC Overvoltage protection (time) 350V / 2 h Overvoltage protection DALI interface 264 V / permanent Max. leakage current 0.5 mA EN 61 00-3-2 EN 6100-3-3 EN 61547 EN 55015 Designations • Constant lamp output independent of mains voltage fluctuations • Automatic restart after lamp replacement • Suitable for direct current operation and emergency lighting installations; complies with requirements for emergency lighting according to EN 61347- 2-3/J • Quick restart of lamps after short power disruptions • Energy efficiency EEI=A1 • Nominal service life: 50.000 h with failure rate of ≤ 10% and operation at tc=tc,max 152 Product Catalogue 2014 | BAG electronics push Operating data Lamp designation W W A kHz BCD18.1-2Q-01/ 220-240/DALI 10096395 1 x TC-DEL 18 20 0.09 48 ... 100 0.96 16 88 ENEC 1 x TC-TEL 18 20 0.09 48 ... 100 0.96 16 88 ENEC BCD57.1/32.2Q-01/ 220-240/DALI 10096397 System rating Input current Operation frequency Power factor Rated power lamps Picture reference Approval for lamps 2 x TC-DEL 18 38 0.17 48 ... 100 0.96 16 88 ENEC 2 x TC-TEL 18 38 0.17 48 ... 100 0.96 16 88 ENEC 1 x T5C 22 27.5 0.12 50 ... 125 0.95 22 88 ENEC 1 x T5C 40 44 0.20 50 ... 125 0.95 40 88 ENEC 1 x T5 24 27.5 0.12 50 ... 125 0.95 24 88 - 1 x T5 39 44 0.20 50 ... 125 0.95 39 88 - 1 x T8 15 18 0.08 50 ... 125 0.92 14 88 - 1 x T8 18 20.5 0.09 50 ... 125 0.92 16 88 - 1 x T8 36 37 0.16 50 ... 125 0.95 32 88 - 1 x T8 38 37 0.16 50 ... 125 0.95 32 88 - 1 x TC-DEL 26 27.5 0.13 50 ... 125 0.95 24 88 ENEC 1 x TC-F 18 21 0.10 50 ... 125 0.92 16 88 ENEC 1 x TC-F 24 27 0.12 50 ... 125 0.95 22 88 ENEC 1 x TC-L 18 21 0.10 50 ... 125 0.92 16 88 ENEC 1 x TC-L 24 27 0.12 50 ... 125 0.95 22 88 ENEC 1 x TC-L 40 45 0.20 50 ... 125 0.95 40 88 ENEC 1 x TC-TEL 26 27.5 0.13 50 ... 125 0.95 24 88 ENEC 1 x TC-TEL 32 37 0.17 50 ... 125 0.95 32 88 ENEC 1 x TC-TEL 42 45 0.20 50 ... 125 0.95 42 88 ENEC 1 x TC-TEL 57 63 0.29 50 ... 125 0.95 57 88 ENEC 2 x T5C 22 53 0.24 50 ... 125 0.95 22 88 ENEC 2 x T5C 40/22 70 0.31 50 ... 125 0.95 22 88 ENEC 2 x T5 24 52 0.23 50 ... 125 0.95 24 88 - 2 x T8 15 34 0.15 50 ... 125 0.95 14 88 - 2 x T8 18 38 0.17 50 ... 125 0.95 16 88 - 2 x T8 36 70 0.31 50 ... 125 0.95 32 88 - 2 x TC-DEL 26 55 0.25 50 ... 125 0.95 24 88 ENEC 2 x TC-F 18 39 0.17 50 ... 125 0.95 16 88 ENEC 2 x TC-F 24 53 0.24 50 ... 125 0.95 22 88 ENEC 2 x TC-L 18 39 0.17 50 ... 125 0.95 16 88 ENEC 2 x TC-L 24 53 0.24 50 ... 125 0.95 22 88 ENEC 2 x TC-TEL 26 55 0.25 50 ... 125 0.95 24 88 ENEC 2 x TC-TEL 32 70 0.32 50 ... 125 0.95 32 88 ENEC Dimensions | weights | temperatures Short designation Length X Width Y Height Z Hole spacing XM (length direction) Hole spacing YM (width direction) Hole spacing ZM (height direction) mm mm mm mm mm mm BCD18.1-2Q-01 103 67 30 94 57 28 BCD57.1 / 32.2Q-01 103 67 30 11 90 30 Case drawing Diagram Weight Ambient temperature ta Housing temperature tc,max kg °C °C G 0.139 5 ... 50 75 G 0.162 5 ... 50 75 Electronic control gears (dimmable) | BCD TC DALI Material number Control gear for FL Designation Wiring diagrams 88 Y Ym Y G Xm X Push-DIM L N Push-DIM DA L DA N DA DA 1 2 3 4 5 6 1 2 3 4 5 6 EVG_AB_10096397_Twingle_DALI(110223).eps EVG_AB_10096397_Twingle_DALI(110223).eps BAG electronics | Product Catalogue 2014 153 BCD TC 1-10V Dimmable electronic control gear for CFL, T5 and T8 lamps with Twingle-Technology Electronic control gears (dimmable) | BCD TC 1-10V Product information • Dim interface: 1–10 V • Dim range 3...100% luminous flux • Multi-Power technology for operation of different lamps and wattages on the same ECG • Twingle function: operation with 1 or 2 lamps • Suitable for dimming amalgam lamps Control gear for FL • Electrode preserving warm start for maximum lamp life, even at increased switching frequency; starting time < 1.5 s • Cut-Off technology at 100% luminous flux: minimised heat current through electrodes during operation, for optimum light output and reduced power • Safety switch-off in case of abnormal lamp operation, e. g. defective electrode and end of lamp life; tested acc. to EN 61347-2-3 + Test 2 • Constant lamp output independent of mains voltage fluctuations • Automatic restart after lamp replacement • Suitable for direct current operation and emergency lighting installations; complies with requirements for emergency lighting according to EN 61347- 2-3/J • Quick restart of lamps after short power disruptions • Energy efficiency EEI=A1 • Nominal service life: 50.000 h with failure rate of ≤ 10% and operation at tc=tc,max 154 Product Catalogue 2014 | BAG electronics Industry Office & Commercial Outdoor Shop Technical data Conformity EN 61347-1 Mains voltage supply Rated voltage range 220 ... 240 [V] EN 61347-2-3 Rated frequency 0 / 50 ... 60 [Hz] EN 61347-2-3/C Admissible continuous voltage range (AC) 198 - 264 [V] EN 60929 EN 61 00-3-2 Battery operation Voltage range continuous DC 198 VDC - 278 VDC Voltage short time DC min. 176 VDC Overvoltage protection (time) 350 V / 2 h Max. leakage current 0.5 mA Max. control current (1-10V) 0.2 mA EN 6100-3-3 EN 61547 EN 55015 Designations Operating data BCD18.1-2Q-01/220-240/1- 10096385 10V BCD57.1/32.2Q-01/220240/1-10V 10096387 BCD13.1-2Q-01/220-240/1- 10096393 10V Lamp designation System rating Input current Operation frequency Power factor Rated power lamps Picture reference Approval for lamps W A kHz 1 x TC-DEL 18 20 0.09 50 ... 125 0.96 16 78 ENEC 1 x TC-TEL 18 20 0.09 50 ... 125 0.96 16 78 ENEC 2 x TC-DEL 18 38 0.17 50 ... 125 0.96 16 78 ENEC 2 x TC-TEL 18 38 0.17 50 ... 125 0.96 16 78 ENEC 1 x T5C 22 27 0.12 50 ... 125 0.95 22 78 ENEC 1 x T5C 40 44 0.20 50 ... 125 0.95 40 78 ENEC 1 x T5 24 27 0.12 50 ... 125 0.95 24 78 - 1 x T5 39 43 0.19 50 ... 125 0.95 39 78 - 1 x T8 15 18 0.08 50 ... 125 0.95 14 78 - 1 x T8 18 20 0.09 50 ... 125 0.95 16 78 - 1 x T8 36 36 0.16 50 ... 125 0.95 32 78 - 1 x T8 38 36 0.16 50 ... 125 0.95 32 78 - 1 x TC-DEL 26 27 0.13 50 ... 125 0.95 24 78 ENEC 1 x TC-F 18 20 0.09 50 ... 125 0.92 16 78 ENEC 1 x TC-F 24 26 0.12 50 ... 125 0.95 22 78 ENEC 1 x TC-L 18 20 0.09 50 ... 125 0.92 16 78 ENEC 1 x TC-L 24 26 0.12 50 ... 125 0.95 22 78 ENEC 1 x TC-L 40 44 0.20 50 ... 125 0.95 40 78 ENEC 1 x TC-TEL 26 27 0.13 50 ... 125 0.95 24 78 ENEC 1 x TC-TEL 32 36 0.16 50 ... 125 0.96 32 78 ENEC 1 x TC-TEL 42 45 0.20 50 ... 125 0.95 42 78 ENEC 1 x TC-TEL 57 63 0.28 50 ... 125 0.95 57 78 ENEC 2 x T5C 22 52 0.23 50 ... 125 0.95 22 78 ENEC 2 x T5C 40/22 69 0.30 50 ... 125 0.95 22 78 ENEC 2 x T5 24 52 0.23 50 ... 125 0.95 24 78 - 2 x T8 15 34 0.15 50 ... 125 0.95 14 78 - 2 x T8 18 38 0.17 50 ... 125 0.95 16 78 - 2 x T8 36 70 0.31 50 ... 125 0.95 32 78 - 2 x TC-DEL 26 55 0.25 50 ... 125 0.95 24 78 ENEC 2 x TC-F 18 38 0.17 50 ... 125 0.95 16 78 ENEC 2 x TC-F 24 52 0.23 50 ... 125 0.95 22 78 ENEC 2 x TC-L 18 38 0.17 50 ... 125 0.95 16 78 ENEC 2 x TC-L 24 52 0.23 50 ... 125 0.95 22 78 ENEC 2 x TC-TEL 26 55 0.25 50 ... 125 0.95 24 78 ENEC 2 x TC-TEL 32 70 0.31 50 ... 125 0.96 32 78 ENEC 1 x TC-DEL 13 16 0.07 50 ... 125 0.96 13 78 ENEC Electronic control gears (dimmable) | BCD TC 1-10V Material number Control gear for FL Designation 1 x TC-TEL 13 16 0.07 50 ... 125 0.96 13 78 ENEC 2 x TC-DEL 13 32 0.13 50 ... 125 0.98 13 78 ENEC 2 x TC-TEL 13 32 0.13 50 ... 125 0.98 13 78 ENEC Diagram Weight Ambient temperature ta Housing temperature tc,max Dimensions | weights | temperatures Short designation Length X Width Y Height Z Hole spacing XM (length direction) Hole spacing YM (width direction) Hole spacing ZM (height direction) mm mm mm mm mm mm kg °C °C BCD18.1-2Q-01 103 67 30 94 57 28 G 0.132 5 ... 50 75 BCD57.1 / 32.2Q-01 103 67 30 94 57 28 G 0.157 5 ... 50 75 BCD13.1-2Q-01 103 67 30 94 57 28 G 0.132 5 ... 50 75 Wiring diagrams G 78 Ym Y Case drawing Y 1−10 V Xm X 1 2 3 4 5 6 BAG electronics | Product Catalogue 2014 155 BCD CFL and T5-C 1-10V Dimmable electronic control gear for CFL and T5-C lamps Electronic control gears (dimmable) | BCD CFL and T5-C 1-10V Product information • Dim interface: 1–10 V • Dim range 3...100% luminous flux • Multi-Power technology for operation of different lamps and wattages on the same ECG • Suitable for dimming amalgam lamps Control gear for FL • Electrode preserving warm start for maximum lamp life, even at increased switching frequency; starting time < 1.5 s • Cut-Off technology at 100% luminous flux: minimised heat current through electrodes during operation, for optimum light output and reduced power • Safety switch-off in case of abnormal lamp operation, e. g. defective electrode and end of lamp life; tested acc. to EN 61347-2-3 + Test 2 • Constant lamp output independent of mains voltage fluctuations • Automatic restart after lamp replacement • Suitable for direct current operation and emergency lighting installations; complies with requirements for emergency lighting according to EN 61347- 2-3/J • Quick restart of lamps after short power disruptions • Energy efficiency EEI=A1 • Nominal service life: 50.000 h with failure rate of ≤ 10% and operation at tc=tc,max 156 Product Catalogue 2014 | BAG electronics Industry Office & Commercial Outdoor Shop Technical data Conformity EN 61347-1 Mains voltage supply Rated voltage range 220 ... 240 [V] EN 61347-2-3 Rated frequency 0 / 50 ... 60 [Hz] EN 61347-2-3/C Admissible continuous voltage range (AC) 198 - 264 [V] EN 60929 EN 61 00-3-2 Battery operation Voltage range continuous DC 198 VDC - 278 VDC Voltage short time DC min. 176 VDC Overvoltage protection (time) 350V / 2 h Max. leakage current 0.5 mA Max. control current (1-10V) 0.2 mA EN 6100-3-3 EN 61547 EN 55015 Designations Designation Material number Lamp designation System rating Input current Operation frequency Power factor Rated power lamps Picture reference Approval for lamps W W A kHz BCD36.2Q-01/220-240/110V 10096326 2 x TC-L 36 70 0.31 40 ... 120 0.95 32 78 ENEC BCD55.1Q-01/220-240/110V 10096388 1 x T5C 55 59 0.26 40 ... 120 0.98 55 63 ENEC BCD60.1Q-01/220-240/110V 10096389 1 x T5C 60 64 0.28 40 ... 120 0.98 60 63 ENEC BCD42.2Q-01/220-240/110V 10097580 2 x TC-DEL 26 55 0.24 40 ... 120 0.98 24 73 ENEC 2 x TC-TEL 26 55 0.24 40 ... 120 0.98 24 73 ENEC 2 x TC-TEL 32 70 0.31 40 ... 120 0.98 32 73 ENEC 2 x TC-TEL 42 90 0.40 40 ... 120 0.95 42 73 ENEC Dimensions | weights | temperatures Short designation Length X Width Y Height Z Hole spacing XM (length direction) mm mm mm BCD36.2Q-01 103 67 30 BCD55.1Q-01 103 67 30 94 Hole spacing YM (width direction) Hole spacing ZM (height direction) Diagram mm mm mm 94 57 28 G 57 28 G Weight Ambient temperature ta Housing temperature tc,max kg °C °C 0.156 5 ... 50 80 0.142 5 ... 50 80 BCD60.1Q-01 103 67 30 94 57 28 G 0.142 5 ... 50 80 BCD42.2Q-01 123 102 33 94 90 30 G 0.237 5 ... 50 75 Case drawing Wiring diagrams 63 Zm Z G Y 1−10 V Xm X Control gear for FL 1 2 3 4 Electronic control gears (dimmable) | BCD CFL and T5-C 1-10V Operating data 73 L N 1−10 V 1 2 3 4 5 6 7 8 78 1−10 V 1 2 3 4 5 6 BAG electronics | Product Catalogue 2014 157 Accessories Diffusor for linear LED modules Product information • Plastic profile for ASTARES linear LED modules 2nd Generation • 3 different standard lengths • Toolless clip fastening on holder element • Suitable as protection against touching in case of non-SELV operation • Diffuse light distribution with high optical system efficiency of 94% • Material: PMMA; white 1,2 5 Model 22,10 R1 8 3 Drawing 46,20 Material Number Length [mm] Diffusor ASTARES linear L593 10111464 593 Diffusor ASTARES linear L1131 10111463 1131 Diffusor ASTARES linear L1431 10111461 1431 Holder element Product information • Holder element for ASTARES linear LED modules 2nd Generation • Optimized thermal-mechanical fixation of LED module • Toolless clip fastening of optical covers (optional) • M4 screw with TORX drive included • Material: PBT, white Zubehör 158 Product Catalogue 2014 | BAG electronics Model Material Number Dimensions [mm] Holder element ASTARES Linear 10111465 38 x 13,6 x 9 Accessories Release spike Product information • Operating tool for wire release • Suitable for terminals with release hole • Ergonomic soft grip handle • Flattened spike with 1,0 mm diameter and depth gauge Model Release spike Material Number Dimensions [mm] 10075741 138 x 20 x 20 ZITARES Programming Tool Product information • Programming tool for parameter setting and monitoring of ZITARES DALI ECGs • To be used together with ZITARES 360 PC software • USB port (2.0; type B) for standard PC connection; Push-in termianls for flexible wiring of ECGs • Optional auxiliary DC power input for increase of DALI bus supply current • Status indication (data transmit, data receive, power) by coloured LEDs • Compact housing with terminal cover and strain reliefs Material Number Dimensions [mm] ZITARES Programming Tool 10112596 180 x 86 x 33 Zubehör Model ZITARES 360 Programming Software Product information • ZITARES 360 graphical user interface for programming and analysis of ZITARES DALI ECGs • System requirement: PC with Microsoft Windows incl. USB port • Separated user levels for development, production and analysis of operation • Intuitively use of software supported by integrated FAQ • Direct ECG plug & program solution for fast programming • Full traceability concept T5 Please contact us for further information and software download. BAG electronics | Product Catalogue 2014 159