DATA SHEET: TEMBREAK 2 L400-PE MCCB WITH Icu = 70kA @ 690V AC MCCB Electrical Characteristics to IEC 60947-2, EN 60947-2, JIS C 8201-2-1 ANN.1, AS/NZS 3947-2 Frame Reference Quantity Unit Condition TB2 H/L 400 Maximum In (A) of Frame 400 Model Number of Poles Type L400 3 PE Nominal current Ratings In (A) 50°C Rated operational voltage Rated insulation voltage Rated impulse voltage Ue Ui U imp (V) (V) (kV) AC 50/60 Hz 690 800 8 Ultimate breaking capacity (IEC, JIS,AS/NZS) I cu (kA) 690V AC 70 Service breaking capacity (IEC, JIS,AS/NZS) I cs (kA) 690V AC 50 Rated short-time withstand I cw (kA) 0.3 Seconds 5 250, 400 Electrical characteristics Protection Adjustable thermal, adjustable magnetic Microprocessor Utilisation Category B Installation Front Connection (FC) Extension Bar (FB) Cable Clamp (FW) Rear Connection (RC) Plug-in (PM) Din Rail Mounting (DA) Dimensions: Weight - height width depth (mm) (mm) (mm) 3 pole weight (kg) 3 pole • 260 140 140 7.1 Operation Direct Opening Action Toggle operation Door mounted (HS)/ Breaker mounted handle (HB) Motor operation Endurance • • Electrical Mechanical cycles cycles 1,000 4,000 690V AC Standard • Optional - Not Available Page 1 of 4 DATA SHEET: TEMBREAK 2 L400-PE MCCB WITH Icu = 70kA @ 690V AC Outline Dimensions L400-PE ASL: Arrangement Standard Line HL: Handle Frame Centre Line Rear connected Insulation plate ✽ 83.5 78.5 Insulation plate ✽ Groove for dissipating heat generated by overcurrent HL Terminal cover 5 HL 1.6 Mounting plate Stud can be turned 45 or 90 60 140 60 83.5 78.5 260 140 39 108.4 110 Conductor overlap, max 15 70 68.4 51 ø1 3 CL 1.6 Insulation plate ✽ 260 427 270 116 30 45 45 Mounting plate M6 Tapped hole 135.6 141.6 183.6 8 ✽ Be sure to install the insulation plates (supplied as standard). Note: Studs are factory installed in horizontal direction both on the line and load sides. Panel cutout dimensions shown give an allowance of 1.0mm around the handle escutcheon. Rear connected with Motor Operator 140 136 Insulation plate ✽ 1.6 Mounting plate Groove for dissipating heat generated by overcurrent 15 Stud can be turned 45 or 90 175 250 5 Manual operating handle (removable) Terminal cover 108.4 110 39 15 ø1 Conductor overlap, max 3 70 68.4 1.6 Insulation plate ✽ 30 45 45 Mounting plate 16 176.1 ✽ Be sure to install the insulation plates (supplied as standard). Note: Studs are factory installed in horizontal direction both on the line and load sides. Panel cutout dimensions shown give an allowance of 1.5mm around motor operator. Page 2 of 4 DATA SHEET: TEMBREAK 2 L400-PE MCCB WITH Icu = 70kA @ 690V AC Outline Dimensions L400-PE, Plug in Version ASL: Arrangement Standard Line HL: Handle Frame Centre Line Termination of Busbar Outline Dimensions Preperation of conductor 5 Terminal cover 20 (max.) 20 (max.) ø11 8 Mounting screw M10✕30 max. 188 30 (max.) 230 8 (max.) Mounting on a support or rails (shown with optional connection bars oriented for rear access) 5 Terminal cover 8 188 Mounting Angle 230 Mounting through the backplate (shown with optional connection bars oriented for rear access) 113 102 Mounting plate Mounting Plate 198 258 276 260 102 90 6t 5 6t Mounting screw M5✕20 Terminal cover 8 134 175 217 65 48 Mounting on the backplate (optional connection bars must be oriented for front access) Insulating plate ✽ 33 32 1 Mounting screw M6✕70 Mounting plate 6t 260 102 90 5 Terminal cover CL 134 32 8 241 283 1 12 Insulating plate ø13 Mounting plate ✽ Be sure to install the insulation plates (supplied as standard). Insulating plate ✽ Page 3 of 4 DATA SHEET: TEMBREAK 2 L400-PE MCCB WITH Icu = 70kA @ 690V AC Time/Current Characteristic Curves L400-PE Percent Rated Current In Percent Rated Current IR In = 400A; 250A Note (1) IR (A) LTD Pick-up current Characteristics Standard LT ST INST PTA Option gF Note(4) NP tR Isd tsd Ii Ip tp Ig tg IN tN IR No. (s) xIR (s) xIR xIR (s) xIn (s) xIR (s) xIn 0.4 1 11 0.5 2 21 at 200% x IR 2.5 0.1 0.63 3 21 0.8 4 5 0.9 0.95 5 6 10 19 at 600% x IR 5 10 0.2 14(Max: 13 x In) Note (2) 0.8 40 0.2 0.2 1.0/0.5 Note (3) 1.0 7 29 tN=tR Note (1) gF is not available when In is 250A. (2) Ii max. = 13 x In. (3) 1.0 x IR or 0.5 x IR can be selected. Characteristic of neutral protection (tN vs. IN) is identical to characteristic of phase protection (tR vs. IR). (4) When you specify gF on MCCBs with 3 poles the terminal block is automatically fitted to connect with the external neutral CT for 3 phases 4 wires system. See terminal blocks in section 4. Page 4 of 4