50KQA, KQD007-019 CONSOLE WATER SOURCE HEAT PUMPS

advertisement
50KQ-3SB
TM
50KQA, KQD007-019
CONSOLE WATER SOURCE
HEAT PUMPS
— PERFORMANCE DATA
— CERTIFIED DIMENSION PRINTS
© Copyright 2002 Carrier Corporation • Syracuse, New York 13221
Form 50KQ-3SB
Replaces: 50KQ-2SB
Printed in U.S.A.
7-02
Catalog No. 515-00017
Date:
Supersedes:
50KQA
50KQD
50KQA, KQD007-019
CONSOLE WATER SOURCE HEAT PUMPS
JOB NAME:
LOCATION:
BUYER:
BUYER P.O.#
UNIT NUMBER:
MODEL NUMBER:
PERFORMANCE DATA CERTIFIED BY:
Rev:
-3SB
CARRIER#
DATE:
DESCRIPTION
The 50KQA and KQD Water Source Heat Pumps are single package consoles with self-contained line voltage thermostats for commercial
applications. Units are factory wired, piped, charged and tested, ready for installation. The low temperature unit (50KQD) is available with an
extended operating range of 40 to 110 F.
STANDARD FEATURES
Standard safety features include: high-pressure switch, freeze protection switches,
and loss of charge protection.
Each unit is run tested at the factory to ensure proper operation of all components
and safety switches.
Anti-short cycle timer provides a minimum off-time to prevent unit from short
cycling.
Fan motors and compressors are sound isolated.
The water-to-refrigerant heat exchanger has copper inner and steel outer tubing to
provide corrosion resistance protection.
Units are ARI (Air Conditioning & Refrigeration Institute) Standard 320-93
certified.
Filter racks permit easy filter replacement.
Convenient large service access panels can be used for on-site testing or refrigerant recovery.
The standard Complete C electronic controls provide short cycle protection,
random start, remote alarm, and intelligent reset. Self-diagnostic capability
includes fault-type indication and memory.
An optional Deluxe D electronic controller offers advanced system control capabilities such as night setback and emergency shutdown.
PERFORMANCE DATA
UNIT
Operating Weight _____________________________________________ lbs
Shipping Weight______________________________________________ lbs
COOLING
Total Capacity_______________________________________________Btuh
Sensible Capacity ____________________________________________Btuh
Unit CFM ____________________________ at ______________ in. wg ESP
Total Heat of Rejection________________________________________Btuh
Entering Air Temperature_______________ °F db ________________°F wb
Entering Water Temperature______________________________________°F
Leaving Water Temperature ______________________________________°F
GPM_________________________________________________________
Water Pressure Drop____________________________________________ ft
Unit Power Input _____________________________________________kW
EER (ARI) ____________________________________________________
HEATING
Total Capacity ______________________________________________ Btuh
Unit CFM ___________________ at _______________________in. wg ESP
Total Heat of Absorption______________________________________ Btuh
Entering Air Temperature _______________________________________ °F
Entering Water Temperature _____________________________________ °F
Leaving Water Temperature _____________________________________ °F
GPM _________________________________________________________
Water Pressure Drop ____________________________________________ ft
Unit Power Input________________________________________________
COP (ARI) ____________________________________________________
ELECTRICAL DATA
Power Supply to Unit _________ Volts___________Phase__________Hertz
Compressor RLA _______________________________________________
Fan FLA ______________________________________________________
Unit Minimum Circuit Amps ______________________________________
Maximum Fuse Amps____________________________________________
FACTORY-INSTALLED OPTIONS
Return Air Configurations:
Return Bottom, Discharge Top with Left or Right configuration
Return Front, Discharge Top with Left or Right configuration
Base:
3-in. base
5-in. base
Deluxe D Controls
Locking Control Panel
2
Motorized Damper
Motorized Water Valve
Autoflow Regulator, 2.5 GPM per ton
Autoflow Regulator, 3.0 GPM per ton
PremierLink™ Controller
Fused or Unfused Disconnect Switch
20 A Plug and Cord
Cupronickel Heat Exchangers
FIELD-INSTALLED ACCESSORIES
Hose Kit (Stainless steel or galvanized)
Hose Kit assemblies with GPM Autoflow valves
Ball Valves (with and without Pressure Temperature ports)
Y Strainers (with plugs and blow down valves)
Solenoid Valves
Thermostats
Loop Controllers
Adjoining Room Kit
Discharge Grille for Adjoining Room Kit
Duct Extension for Adjoining Room Kit
__________________________________________________________
CERTIFIED DIMENSION PRINT
50KQA,KQD BOTTOM RETURN CABINET DIMENSIONS — RIGHT-HAND PIPING
5
(127)
16
(406)
1 1/2
(38)
Air
Discharge
30°
Control Access Door
24
(610)
Air
Inlet
AIR INLET AREA
9 1/2
(241)
48
(1219)
10
(254)
FRONT VIEW
9 1/2
(241)
3
(76)
R.H. Pipe &
Electric Area
7 1/4
(184)
1 1/2
(38)
1 1/2
(38)
3 1/4
(83)
1 (25)
1 (25)
*Optional 5-in. (127) subbase will increase damper
opening to 3.63 in. (92)
high and increase overall
unit height by 2 in. (51).
4 1/2
(114)
REAR VIEW
REAR
ACCESS
21
(533)
1 5/8
(41)
DAMPER OPENING*
11 3/4
(298)
48
(1219)
3
(76)
13/16
(20)
OPTIONAL DAMPER
18 1/8
(460)
NOTE: All measurements in inches. Measurements in parentheses are in millimeters.
3
CERTIFIED DIMENSION PRINT
50KQA,KQD BOTTOM RETURN CABINET DIMENSIONS — LEFT-HAND PIPING
12 1/2
(317)
1 1/2
(38)
1 1/2
(38)
Air
Discharge
30°
Control Access Door
24
(610)
AIR INLET AREA
AIR
INLET
48
(1219)
9 1/2
(241)
7 1/4
(184)
1 1/2
(38)
3
(76)
10
(254)
FRONT VIEW
L.H. Pipe &
Electric Area
9 1/2
(241)
1 1/2
(38)
3 1/4
(83)
1 (25)
*Optional 5-in. (127) subbase will increase damper
opening to 3.63 in. (92)
high and increase overall
unit height by 2 in. (51).
1
(25)
REAR VIEW
4 1/2
(114)
REAR
ACCESS
21
(533)
1 5/8
(41)
DAMPER OPENING*
11 3/4
(298)
13/16
(20)
3
(76)
18 1/8
(460)
48
(1219)
NOTE: All measurements in inches. Measurements in parentheses are in millimeters.
4
OPTIONAL DAMPER
CERTIFIED DIMENSION PRINT
50KQA,KQD FRONT RETURN CABINET DIMENSIONS — RIGHT-HAND PIPING
AIRFLOW OPTIONS
PLAN VIEW
16
(406)
5
(127)
1 1/2
(38)
Air
Discharge
30°
Control Access Door
21
(533)
Filter
Air
Inlet
48
(1219)
10
(254)
FRONT VIEW
NO DAMPER AVAILABLE WITH FRONT RETURN OPTION.
1 1/2
(38)
41 3/4
(1041)
R.H. PIPE &
ELECTRIC AREA
9 1/2
(241)
BLOCK OFF PLATE ON
BOTTOM OF CHASSIS
1 1/2
(38)
48
(1219)
3 1/4
(83)
1
(25)
1
(25)
4 1/2
(114)
REAR VIEW
21
(533)
REAR
ACCESS
48
(1219)
NOTE: All measurements in inches. Measurements in parentheses are in millimeters.
5
CERTIFIED DIMENSION PRINT
50KQA,KQD FRONT RETURN CABINET DIMENSIONS — LEFT-HAND PIPING
12.5
(318)
1.5
(38)
1.5
(38)
Air
Discharge
30°
Control Access Door
21
(533)
Filter
Air
Inlet
48
(1219)
FRONT VIEW
10
(254)
NO DAMPER AVAILABLE WITH FRONT RETURN OPTION.
41.75
(1060)
1.5 (38)
L.H. PIPE &
ELECTRIC AREA
9.5
(241)
BLOCK OFF PLATE ON
BOTTOM OF CHASSIS
0.75 (19)
3.5
(89)
48
(1219)
1 (25)
4.5
(114)
REAR VIEW
REAR
ACCESS
20
(508)
48
(1219)
NOTE: All measurements in inches. Measurements in parentheses are in millimeters.
6
1
(25)
21
(533)
CERTIFIED DIMENSION PRINT
CHASSIS DIMENSIONS 50KQA,KQD007,009,012,015,019
POWER
SUPPLY IN
3 3/8 (86)
41
(1041)
2 (51)
1 (25)
WATER OUT
30°
WATER
IN
CONTROL BOX
4 (182)
3 1/2
(89)
6 1/2
(165)
1 5/16
(33)
20 7/16
(519)
2
(51)
16 9/16
(420)
13 1/2 (343)
BLOWER DECK
CONDENSATE
RELIEF
COMPRESSOR
ACCESS
PANEL
BLOWER ACCESS PANEL
3 9/32
(83)
3/4
(19)
9 1/2 (241)
3/4
(19)
FRONT VIEW (LH)
SIDE VIEW (LH)
POWER
SUPPLY IN
3 3/8 (86)
41
(1041)
2 (51)
WATER
IN
1 (25)
30°
WATER
OUT
CONTROL BOX
4 (182)
20 7/16
(519)
3 1/2 (89)
BLOWER DECK
6 1/2
(165)
2 (51)
16 9/16
(420)
BLOWER ACCESS PANEL
COMPRESSOR
ACCESS
PANEL
3/4
(19)
3/4
(19)
FRONT VIEW (RH)
13 1/2 (343)
CONDENSATE
RELIEF
1 1/2
(33)
1 (25)
9 1/2 (241)
SIDE VIEW (RH)
NOTE: All measurements in inches. Measurements in parentheses are in millimeters.
7