LM-TLS DALI DALI daylight control module 3x, cabinet Art. no. 22154141 Helvetica Helvetica Helvetica Helvetica LT LT Std LT Cond Std LTroom. Light Cond Light Std Device for controlling 3 continuous row luminaires depending on the daylight available inStd the Application The LM-TLS/DALI daylight-dependent control system is used in rooms where particularly stringent requirements as regards lighting must be met. With this system, the artificial light is continuously adjusted, depending on the daylight available in the room. In this way, any loss of daylight is compensated by artificial light. The three outputs are controlled independently of each other by means of DALI broadcast commands.Daylight-based lighting controls can also help save energy. Design notes • The operating devices connected to each DALI output cannot be individually addressed and controlled. • A maximum of 64 DALI-compatible operating devices can be connected to a DALI output. Variant LM-TLS/DALI(V) art. no. 22 154 250 The following functions can be defined when ordering the product variant LMTLS/DALI(V): • which of the 3 out of 20 possible scenes should be controlled dependent on daylight • whether external luminaire outputs connected to the LUXMATE bus should be controlled at the same time • whether the lighting should be adjusted for brightness by daylight dependent control or by user intervention, and whether all DALI outputs should then be switched on together or individually • whether the lighting should also be dimmed out automatically Functional description • whether all DALI outputs should always be dimmed out together • The LM-TLS/DALI control device controls 3 luminaire groups dependent on the level of natural light in the room. The natural light entering the room is registered with an LSD light sensor and the value measured is used to calculate the amount of artificial light required. A separate control characteristic curve can be programmed for each of the 3 DALI luminaire groups and used for adjusting the artificial light to compensate for changes in the amount of natural light. • whether the On/Off switch should operate as a key switch, i.e. in the “Off” position operation over the momentary action switches T>/T< is locked • whether the control units with a display (e.g. LM-EG) should indicate whether automatic operation is selected or not • further functions upon request. • The lighting can be switched on and off using a connected “ON/OFF” switch. • The luminaires operated over the 3 DALI outputs are dimmed brighter or darker by means of momentary action switches connected to the inputs “T>” and “T<”. • The switch connected to Man/Auto is used to switch between the modes Daylight and Manual. • Scene call-ups are possible via the operating devices connected to the LUXMATE bus. We reserve the right to make technical changes without prior notice. 01.10.2016 © Zumtobel - 5-year guarantee in compliance with the terms of guarantee at www.zumtobel.com/guarantee Wiring scheme Technical data Nominal voltage Permitted input voltage Power loss Inputs Netz/ L1 Mains/ L2 installation instructions Mounting Réseau/ and Rete/ L3 • If required, Red/ N several momentary action switches (T>/T<) may be wired in Net PE parallel. One momentary action switch must not be operated on several LUXMATE-Bus B1action switch inputs (LM-TLS/DALI). All connected inputs must momentary Bus LUXM ATE B2 have identical phases. The lower terminals of the inputs On/Off, Man/Auto, T> and T< are connected internally with the L-terminal. The current through the internal connection must not exceed ** 1A. Outputs LSD Interne Durchgangsverdrahtung! Internal through wiring! Câblage interne! Cablaggio di passaggio interno! Cableado de paso interno! Interne doorgaande bekabeling! • The LSD light sensor is directly connected to the LM-TLS/DALI. The LSD must be installed with an unobstructed view towards the window. (Follow L N PE installation manual!) B1 B2 S1 S2 DADADADA DADA DA Dimension Sensor in Grp1 Grp2 Grp3 DALI out DA LM-TLS DALI L N L On/ Off Man/ Auto T DALI ballast T * L N PE DA DA DALI ballast L N PE DA DA DALI ballast L N PE DA DA *** * Eintastersteuerung Single switch control Commande par bouton-poussoir simple Comando per pulsante singolo Control por pulsador simple Eentoetsbesturing ** Group lll R1G3M3 Addressing Operating mode LN PE DALI control wiring DA DA Control range Terminals Protection type LN Housing material PE DA DA Installation Dimensions L N PE DALI ballast DALI ballast DALI 230/240 V AC, 50/60 Hz 207-264V AC, 50-60Hz <9W 230/240 V AC, 50/60 Hz 1 LSD light sensor (2 x 1,5 mm²; max. 250 m) LUXMATE bus (B1, B2) 4 single-pole inputs 15 V 3 DALI control outputs each with 64 DALI compatible lamp operating devices max. 64 DALI compatible operating devices per output 1 room, group, individual address per output L INTENS (brightness 02) N DALI H05VV-U 2 x 1.5 PE mm², max. 250 m per output ballast DA DA 0; 1-100 % (relative luminous intensity) 0,75 ... 2,5 mm² L IP20 N DALI PE ballast Polycarbonate (PC), halogen-free, flame retardant DA DA On 35 mm top-hat rail according to EN 50022 8 units at 17,5 mm 140 x 90 x 59 mmLN DALI PE 0 °C ... +50 °C DA ballast Permitted ambientDA ballast DA DA temperature L N PE DA DA L N PE DA kg DA Weight Approx. 0.4 Miscellaneous Status indication of operating state *** ***LED for Group Group ll l Momentary action test switch for testing the R1G2M2 R1G1M1 installation ACHTUNG: Der Lichtsensor LSD ist mit freiem Blick Richtung Fenster zu montieren. (Montageanleitung beachten!) PLEASE NOTE: The LSD light sensor must be installed with an unobstructed view towards the window (please obse rve installation instructions!) ATTENTION: La cellule photoélectrique LSD s'installe avec l'œil dirigé vers la fenêtre (consulter la notice de montage!) ATTENZIONE: II fotosensore LSD deve essere montato in direzione della finestra senza ostacoli davanti. (Osse rvare le istruzioni di montaggio!) ATENCION: El sensor de luz LSD debe montarse de tal modo que no haya obstáculos entre él y la ventana. (¡Consulte las instrucciones de montaje!) LET OP: De lichtcel LSD met vrij uitzicht richting raam monteren. (Montagehandleiding volgen!) 64 DALI-kompatible Lampenbetriebsgeräte *** max. max. of 64 lamp control gear DALI-compatible max. 64 ballast électronique compatible DALI max. 64 reattori compatibili DALI máx. 64 dispositivos de control de lámparas compatibles con DALI max. 64 DALI-compatibele hulpapparaten voor lampen Label/connections Mounting and installation instructions Technical data • If required, several momentary action switches (T>/T<) may be wired in parallel. One momentary action switch must not be operated on several momentary action switch inputs (LM-TLS/DALI). All connected inputs must have identical phases. The lower terminals of the inputs On/Off, Man/Auto, T> and T< are connected internally with the L-terminal. The current through the internal connection must not exceed 1A. Nominal voltage Permitted input voltage Power loss Inputs • The LSD light sensor is directly connected to the LM-TLS/DALI. The LSD must be installed with an unobstructed view towards the window. (Follow installation manual!) Dimension Outputs Addressing Operating mode DALI control wiring Control range Terminals Protection type Housing material Installation Dimensions Permitted ambient temperature Weight Miscellaneous 230/240 V AC, 50/60 Hz 207-264V AC, 50-60Hz <9W 1 LSD light sensor (2 x 1,5 mm²; max. 250 m) LUXMATE bus (B1, B2) 4 single-pole inputs 3 DALI control outputs each with 64 DALI compatible lamp operating devices max. 64 DALI compatible operating devices per output 1 room, group, individual address per output INTENS (brightness 02) H05VV-U 2 x 1.5 mm², max. 250 m per output 0; 1-100 % (relative luminous intensity) 0,75 ... 2,5 mm² IP20 Polycarbonate (PC), halogen-free, flame retardant On 35 mm top-hat rail according to EN 50022 8 units at 17,5 mm 140 x 90 x 59 mm 0 °C ... +50 °C Approx. 0.4 kg Status LED for indication of operating state Momentary action test switch for testing the installation Label/connections We reserve the right to make technical changes without prior notice. 01.10.2016 © Zumtobel - 5-year guarantee in compliance with the terms of guarantee at www.zumtobel.com/guarantee