Predator Brochure

advertisement
®
PREDATOR
The Predator floodlight offers
versatility, efficiency, and performance,
which provides a unique solution to a
variety of lighting needs. With the
Predator, Holophane continues its
legacy of utilizing technology to
develop creative and innovative
lighting solutions. Because the
Predator is capable of generating wide,
narrow, and spot distributions and is
able to withstand harsh environmental
extremes, it can be used in a range of
diverse applications. Flexibility in
mounting positions is maximized with
its 360° yoke. The quick disconnect
removable door, which includes all
electrical components, can be replaced
in 60 seconds, resulting in decreased
costs and inconvenience of downtime
®
PREDATOR
•
•
•
•
Variety of distributions
Extended component life
Variety of mounting methods
UL, CUL, and CSA listed for
general and hazardous locations
Features and Benefits
• Unique
fluted reflector
Produces the maximum amount
of light per input watt with
optimum uniformity. Transverse
elliptical fluting minimizes
redirected energy through the arc
tube and provides streak and
striation free illumination.
• Unitized electrical assembly Quick disconnect fixture
door includes ballast and socket.
Simplifies maintenance through
60 second replacement and
decreases costs through minimal
downtime.
2 – 4 mil TGIC polyester powder
paint, and hollow core high
temperature silicone gaskets.
• Corrosion resistance Con-
• 40°C
struction consists of low copper
(360.1 alloy) aluminum castings,
phosphate
pretreatment,
UL listing Extends
ballast and capacitor life 100% if
operated in 25°C (77°F) average
ambients.
BRIDGES
PAPER MILLS
POWER PLANTS
PETROCHEMICAL
PLANTS
WASTEWATER
FACILITIES
BUILDING FACADES
PARKING LOTS
OUTDOOR SECURITY
Application versatility
Normal environment - UL/
CUL 1598
• Protected
HPS starter
Protects starter and ballast from
damage when lamp fails.
• Mounting
versatility 360°
yoke for 100% flexibility. Knuckles
for 2 and 4 inch tenons. Junction
box mount.
• Stainless
steel exposed
hardware Provides long useful
life in harsh locations.
• Low Energy Use Holophanemanufactured ballasts provide
highest lamp wattage with lowest
input watts. Optional low loss
ballasts in 250 – 400W MH reduce
losses by an additional 10 to 20
watts per fixture.
• “Suitable
for
Wet
Locations”
Harsh environment - UL 844
• Class I, Division 2
• Class II, Division 1 & 2 (small
Predator only)
• Class III, Division 1 & 2 (small
Predator only)
• CSA Certified
UL 1598A*
• Marine Outside
*There are 4 levels of marine listings
defined by UL 1598A, with Marine
Outside having the most severe requirements.
®
PREDATOR
®
PREDATOR
Predator “CI” Fixtures
Class I, Division 2
Groups A, B, C, D
Hazardous Locations
Predator has been designed and
tested in accordance with UL
Standard 844. Therefore, it
complies with Article 501.9(B) (2)
of the National Electrical Code,
specifically, “tested in order to determine the marked operating
temperature or temperature range.”
Predator “CII” Fixtures
Class II, Division 1 & 2
Groups E, F, G
Class III, Division 1 & 2
Hazardous Locations
Predator has been designed and
tested in accordance with UL
Standard 844 to be “dust-ignitionproof” as required for Class II applications.
The fixture will exclude dust from
the inside of the enclosure and will
function at full rating without developing surface temperatures
high enough to cause excessive
dehydration or gradual carbonization of any organic dust deposits
that may build up. Maximum
surface temperatures will not
exceed 200°C (392°F) Group E and
Group F or 165°C (329°F) Group G
under normal conditions of use.
All temperature classifications are for 40°C ambient temperature.
Table 1 lists the UL tested maximum operating temperatures for lamp type and wattage based on
operation in the specific ambient for which it is approved. Please refer to the Maximum Surface
Temperature Code Table of the NEC.
Table 1 Predator Temperature Classification for Class I, Division 2, Hazardous Locations and Class II, III,
Division 1 & 2, Hazardous Locations.
Lamp Type
& Wattage
Class I, Division 2
Maximum
Mounting
Temp. °C Code Restriction
50W HPS
70W HPS
100W HPS
150W HPS 55V
150W HPS 100V
250W HPS
400W HPS
175W MH
250W MH
400W MH
100W MV
175W MV
250W MV
400W MV
163
178
221
272
244
323
388
306
347
347
247
313
383
383
1
2
3
4
T3B
T3A
T2C
T2A
T2B
325*
T1
325*
350*
350*
T2B
325*
T1
T1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
Lamp Type
& Wattage
Class II, III, Divisions 1 & 2
Maximum
Temp. °C Group
Code
Mounting
Restriction
50W HPS
70W HPS
100W HPS
150W HPS 55V
150W HPS 100V
150W HPS 100V
175W MH
175W MH
100W MV
175W MV
163
178
221
272
244
244
306
306
247
313
2
2
2
3
3
4
3
4
2
2
E,F,G
E,F,G
E,F,G
E,F,G
E,F
E,F,G
E,F
E,F,G
E,F,G
E,F
T4A
T3C
T3C
T3C
T3A
T3B
T3
T3C
T3C
T3
Mounting restricted to lamp vertical, base down, +/- 90°.
Mounting restrictions are referenced to lamp vertical, base down, 25° back of vertical to 90° lens down.
Mounting restrictions are referenced to lamp vertical, base down, vertical to 90° lens down.
Mounting restrictions are referenced to lamp vertical, base down, 90° lens down only.
* UL Standards covering hazardous locations (UL 844) Paragraph 49.10 permits fixtures under Class I, Division 2, which are between 300°C and 450°C to be
marked with 325, 350, 375, 400, 425, 450 to indicate actual maximum temperature. (e.g. Code 325 = 325°C)
Note: Maximum temperatures for lamp type and wattage vary between Class I and Class II & III. Class I is established based upon the maximum temperature
inside or outside the luminaire. Class II and III maximum temperature is based upon external surface temperature.
Class III fixtures will exclude fibers
or flyings from the inside of the
enclosure and will function at full
rating without developing surface
temperature high enough to
cause excessive dehydration or
gradual carbonization of accumulated fibers or flyings.
NEC Requirements — UL Standard 844, File no. E12267
Performance Specification
Table 2. Photometric Data
Source Watts
HPS
50
70
100
150
250
400
MH
175
250
400
DX MV 250
400
1
2
Vertical
Distribution
Narrow
Wide
Narrow
Wide
Narrow
Wide
Narrow
Wide
Spot
Narrow
Wide
Spot
Narrow
Wide
Spot
Narrow
Wide
Spot
Narrow
Wide
Spot
Narrow
Wide
Spot
Narrow
Wide
Spot
Narrow
Wide
Spot
NEMA
Beam1
7x5
7x7
7x5
7x6
7x5
7x6
7x6
7x6
4x4
7x4
7x6
6x4
7x5
7x6
6x5
7x5
7x6
4x4
7x4
7x6
6x4
7x4
7x6
5x4
7x7
7x7
6x6
7x7
7x7
6x7
Beam
Total
Max.
Efficiency2 Efficiency Candela
64.2%
69.4%
63.4%
68.7%
64.3%
68.0%
65.3%
67.6%
47.8%
66.6%
70.1%
64.7%
67.0%
69.6%
64.6%
65.5%
70.9%
51.4%
59.2%
72.2%
56.6%
64.1%
71.4%
59.5%
67.4%
67.0%
66.5%
63.0%
62.5%
64.1%
71.0%
71.7%
70.1%
70.9%
69.5%
70.2%
69.7%
69.9%
72.4%
73.3%
73.4%
75.2%
72.3%
72.8%
74.5%
73.2%
73.4%
80.3%
74.9%
75.9%
77.8%
76.2%
75.7%
79.0%
69.0%
68.3%
71.6%
64.6%
64.0%
68.0%
Photometric
Test #
3172
1898
4556
2595
6264
4117
9658
6358
29994
20075
13852
25719
29653
22441
42203
10834
5527
23696
19769
11815
24413
32262
19407
43500
4981
4440
7066
7126
6513
11106
36339.IES
36363.IES
36337.IES
36361.IES
36335.IES
36359.IES
36333.IES
36347.IES
37019.IES
37199.IES
37200.IES
37198.IES
37196.IES
37191.IES
37197.IES
36343.IES
36367.IES
42320.IES
37218.IES
37219.IES
37217.IES
37202.IES
37201.IES
37203.IES
37224.IES
37225.IES
37223.IES
37208.IES
37207.IES
37209.IES
NCHA beam based on field angle
Beam efficiency based on field angles.Field angles are used because they more accurately represent lumens in beam
Fixture shall be Holophane catalog number
.
Mechanical Construction: The housing shall
be die cast low copper (360.1 alloy) aluminum
finished with a 7-stage pretreatment and an
electrostatically applied 2 - 4 mil coat of polyester
powder paint. The finish shall withstand a 160
inch-pound impact measured with a standard
Gardner Impact Tester. It shall have passed a 1000
hour salt spray test as specified by ASTM B-117. It
shall exhibit no cracking or loss of adhesion from a
180° bend over a 1/8 inch mandrel diameter per
ASTM D522. All external screws shall be captive
and be Type 316 stainless steel. The yoke shall be
either AISI Type 316 stainless steel or zinc electroplated and yellow chromate finished cold rolled
steel. The yoke shall be capable of being rotated
360° about the fixture for top, bottom, or back
mounting. The door shall be hinged to provide
easy access during lamping and shall be secured to
the fixture while open. The door assembly shall
include mechanical stops to assure proper
compression of the gasket. The yoke mounted
fixture shall have a threaded entry to accommodate
1/2” NPT conduit or connector. When the junction
box mount fixture is used, a 1” NPT entry shall be
provided.
Water-tightness: No water shall enter the
fixture when exposed to a solid stream of water
from 3 GG40 brass spray nozzles - each supplying
12 gallons per minute at 100 PSI. The nozzles shall
be 30 inches apart, centered on, and 24 inches
from the fixture plane. Three tests shall be
conducted for 15 minutes each with the vertical
distance of the fixture at 6, 12, and 16 inches
above the nozzles. The gasket shall be hollow
core, Durometer 60 silicone, and have a 200°C
continuous service temperature. It shall have
demonstrated no visible deterioration after artificial
aging for 96 hours in oxygen at a pressure of 300
pounds per square inch at a temperature of 156° F.
Dust-tightness: An enclosure of a fixture for
Class II locations shall be exposed for at least six
heating and cooling cycles and for at least 30 hours
to a circulating dust-air atmosphere to determine
that the fixture is dust-ignition-proof with regard to
exclusion of dust. There shall be no entrance of the
dust into the device as determined by visual
examination following the chamber test described.
The fixture is to be installed in a test chamber to
permit free circulation of the dust-air mixture
around the fixture. The test chamber is to be
provided with a cover and with dust-air-inlet and outlet connections. The fixture is to be exposed to
the dust-air atmosphere that is to be produced by
auxiliary apparatus and introduced into the test
chamber. The tests are to be conducted at an
ambient temperature of 10-40°C (50-104°F) and a
relative humidity of 40-60 percent. Grain dust
consisting of wheat or com dust, or both, that has
passed through a U.S.A. Standard 150-micron
(100-mesh) wire cloth is to be used for the dust-air
atmosphere if the fixture is for Class II, Group F,
Group G, or Groups F and G locations. Magnesium
dust, all of which has passed through a U.S.A.
Standard 250-micron (60 mesh) wire cloth, 66
percent of which has passed through a 150-micron
(100-mesh) wire cloth, and 22 percent of which
has passed through a 75-micron (200-mesh) wire
cloth, is to be used for the dust-air atmosphere if
the fixture is for Class II, Group E, Groups E and F,
Groups E and G, or Groups E, F, and G locations.
Quick Disconnect Electrical: The fixture door
shall contain all ballast components, including the
socket, and be designed for fast removal as a
complete assembly without disturbing aiming. The
fixture shall be capable of being changed to a
different wattage, voltage, or lamp source by
simple change out of the unitized electrical
assembly. Replacement shall take less than 60
seconds.
Optical and Socket Assembly: The reflector
shall consist of high purity alloy #3002 aluminum
of minimum 0.08 thick sheet. Lens shall be 4.5
mm minimum thickness tempered glass. The
beam efficiency shall be no less than ___*___. The
total efficiency shall be no less than ____*___.
Lamp holders shall be porcelain with high
temperature 16 ga. wiring. Sockets shall be pulse
rated. The screw shell shall be nickel-plated brass
with anti-vibration grips.
Ballast: Shall be copper wound, high power
factor, Lead or Low Loss Lead as specified. Ballasts
shall reliably start and operate the lamp in ambient
temperatures to minus 40° F. The lamp
extinguishing voltage shall be as low as 39% of
nominal. Ballast shall provide 100% wattage to
the lamp and have a published Ballast Factor of 1.0
per ANSI C82.2. The fixture shall be UL listed for
40° C. When operated at 10° C below rated
ambient temperature, ballast insulation and
capacitor life shall be extended 100%. The low loss
ballast available for 250 – 400 watt lamps, if
specified, shall have a core of grain oriented M-6
steel to reduce ballast losses 10 to 20 watts per
fixture. A protected started for High Pressure
Sodium lamps, if specified, shall sense an
inoperative lamp and automatically shut down to
prevent continuous pulsing and thermal damage
to itself and ballast secondary windings.
Warranty: The electrical assembly shall be
warranted for a period of 5 years and the luminaire
for a period of 2 years from the date of shipment.
Listing: The fixture shall be UL/CUL 1598 listed
for 40° C ambient “Suitable for Wet Location.” It
shall be UL 844 listed for Class I, Division 2; Class II,
Division 1 & 2; Class III, Division 1 & 2. It shall be
UL 1598A listed for Marine Outside.
*Note: See Table 2 for applicable beam efficiency
and total efficiency.
®
PREDATOR
®
PREDATOR¤
Low copper (360.1
1alloy)Housing:
die cast aluminum with
1
3
polyester powder paint.
Mounting: 360° swivel of
2mounting
yoke around fixture
provides top, bottom, or back mounting.
2
Unique reflector
3designReflector:
eliminates bright streaks,
provides uniform illumination, and
low surface brightness.
5
4 Tempered glass lens
removable
5door:Quick-disconnect
Includes all electrical
4
components, including the socket.
Captive stainless steel screws. Door
does not distort when fastened.
6
Gasket: Hollow core high
temperature silicone gasket.
6
Mounting versatility
Since the yoke can rotate 360°
around the fixture, the Predator
can be mounted from below,
above, or any intermediate position. An optional knuckle fitter,
adjustable in 5° increments, can
be ordered in lieu of the yoke, or
a slip fit adaptor can be supplied
as an accessory to the yoke for
mounting on a 2" tenon. For
ceiling mounting in tunnels or
back mounting for sign lighting,
a box mount can be supplied in
lieu of the yoke to give a 15° tilt
from the mounting plane. The
knuckle fitter, junction box, and
slip fit adaptor options are not
suitable for hazardous locations.
08657 2" Tenon pole adaptor
Junction box mount
Knuckle fitter
Mounting Options
Ordering Data
How to construct a catalog number for Predator
Fixture type_____________________________
EXAMPLE: PD — 050HP — 12 — H — N — 3
1
Catalog no.
2
3
Luminaire type
2
Source and wattage
3
PD
__ 050HP
__ 070HP
__ 100HP
__ 15AHP
__ 175MH
PF
__ 250HP
__ 25LHP
__ 400HP
__ 40LHP
__ 250MH
__ 25LMH
__ 40LMH
__ 250MV
__ 400MV
6
— PS
7
8
Small Predator (UL 844, UL 1598A, UL/CUL 1598, 40°C wet location)
Medium Predator (UL 844 and UL/CUL 1598, 40°C wet location)
50W HPS (120 volt only)
70W HPS
100W HPS
150W/55V HPS
175W MH
250W
250W
400W
400W
250W
250W
400W
250W
400W
H
HPS
HPS, energy saving
HPS
HPS, energy saving
MH
MH, energy saving
MH, energy saving
MV
MV
W
D
2X 10.7mm (.422”)
(2) clearance holes
for mounting bolts
__ 12
__ 20
__ 24
__ 27
__ 34
__ 48
__ MT
120 volt
208 volt
240 volt
277 volt
347 volt (Canada only)
480 volt
Multi-voltage (120 - 277 volt USA) NA with 050HP, 250 and
400MV
Vari-tap (120, 277, 347 volt) Only available with 250HP, 250
MH, 400HP
UL/CUL listing
PD
__ H
__ J
__ K
__ L
PF
__ B
__ K
__ L
Class I only (UL 844)
Class I, II, III, and marine outside (UL 844)
Wet location (UL/CUL 1598)
Marine outside (UL 1598A)
Class I (UL 844), and marine outside (UL 1598A)
Wet location (UL/CUL 1598)
Marine outside (UL 1598A)
5
Optical
6
Mounting
7
Color
8
Options and accessories
__ N
__ W
__ S
__ 1
__ 2
__ 3
__ 4
__ 5
__ G
__ B
__ K
__ W
Protractor
markings
every 15° for a
180° total 2 places
Clearance
holes for
luminaire
mounting
Voltage
__VT
4
5
Description
1
__ PD
__ PF
4
— G
63.5mm (2.5”)
31.8mm (1.25”)
25mm (1.0”)
51mm (2.0”)
(1) 13.5mm (.53”)
hole for wiring
Predator
PD
PF
W
H
D
13.125” 17.875” 7.875”
16.875” 22.75” 10.5”
Effective Projected Area (In Ft2)
Tilt above
Small Predator
Nadir
EPA
15°
1.14
45°
1.66
90°
1.93
135°
1.70
180°
1.14
Weight
20-23 lbs.
39-46 lbs.
Medium Predator
EPA
1.86
2.66
2.87
2.45
1.61
Narrow vertical, wide horizontal beam
Wide vertical, wide horizontal beam
Spot distribution (UL/CUL 1598 & UL 1598A on PD only )
2” Knuckle fitter (UL/CUL 1598 only)
Box mount (UL/CUL 1598 and UL 1598A only)
Stainless steel yoke
Zinc plated yoke (UL/CUL 1598 only)
4” Knuckle fitter (UL/CUL 1598 only)
Gray
Bronze
Black (UL/CUL 1598 on PF only)
White (UL/CUL 1598 on PF only)
See page 8
Order number ___________________
Job name ___________________
®
PREDATOR
Options and Accessories
Wire guard
Visor
Visor & side shield
Catalog no.
Options (factory installed)
__ A
__ C
__ D
__ E
__ F
__ H
__ L
__ J
__ PS
__ R1
_ TB1
Gray top visor
Bronze top visor
Gray side shield (UL/CUL 1598 only)
Bronze side shield (UL/CUL 1598 only)
Black top visor (UL/CUL 1598 on PF only)
White top visor (UL/CUL 1598 on PF only)
Black side shields (UL/CUL 1598 on PF only)
White side shields (UL/CUL 1598 on PF only)
Protected starter for HPS units only
Photocontrol receptacle (NEMA twistlock) (UL/CUL 1598 on PF only)
Terminal block
Accessories (shipped separately)
__ LAMP
Ship appropriate lamp as line item
__ F1
Single fuse assembly for 120, 240, 277, or 347 volt (UL/CUL 1598 only)
__ F2
Double fuse assembly for 208, 240, or 480 volt (UL/CUL 1598 only)
__ PDWG
Wire guard for “PD” unit
__ PFWG
Wire guard for “PF” unit
__ PDPR12
120V photocontrol (UL/CUL 1598 only)
__ PDPR
208, 240, 277V photocontrol (UL/CUL 1598 only)
__ PDPR34
347V photocontrol
__ 08657-xx2
2” tenon pole adapter (UL/CUL 1598 only)
Notes: 1 Contact TSG
2 Insert GR-Gray, BZ-Bronze, BK-Black, WA-White for “xx” in catalog number
Acuity Lighting Group, Inc.
214 Oakwood Ave., Newark, OH 43055 /
Holophane Canada, Inc. 9040 Leslie Street, Suite
208, Richmond Hill, ON L4B 3M4 / Holophane
Europe Limited, Bond Ave., Milton Keynes MK1
1JG, England / Holophane, S.A. de C.V.,
Apartado Postal No. 986, Naucalpan de Juarez,
53000 Edo. de Mexico
Contact your local Holophane factory sales
representative for application assistance, and
computer-aided design and cost studies. For
information on other Holophane products and
systems, call the Inside Sales Service Department
at 740-345-9631. In Canada call 905-7075830 or fax 905-707-5695.
Limited Warranty and Limitation of Liability
Refer to the Holophane limited material
warranty and limitation of liability on this
product, which are published in the “Terms and
Conditions” section of the current product
digest, and is available from our local Holophane
sales representative.
Visit our web site at www.holophane.com
Download