® PREDATOR The Predator floodlight offers versatility, efficiency, and performance, which provides a unique solution to a variety of lighting needs. With the Predator, Holophane continues its legacy of utilizing technology to develop creative and innovative lighting solutions. Because the Predator is capable of generating wide, narrow, and spot distributions and is able to withstand harsh environmental extremes, it can be used in a range of diverse applications. Flexibility in mounting positions is maximized with its 360° yoke. The quick disconnect removable door, which includes all electrical components, can be replaced in 60 seconds, resulting in decreased costs and inconvenience of downtime ® PREDATOR • • • • Variety of distributions Extended component life Variety of mounting methods UL, CUL, and CSA listed for general and hazardous locations Features and Benefits • Unique fluted reflector Produces the maximum amount of light per input watt with optimum uniformity. Transverse elliptical fluting minimizes redirected energy through the arc tube and provides streak and striation free illumination. • Unitized electrical assembly Quick disconnect fixture door includes ballast and socket. Simplifies maintenance through 60 second replacement and decreases costs through minimal downtime. 2 – 4 mil TGIC polyester powder paint, and hollow core high temperature silicone gaskets. • Corrosion resistance Con- • 40°C struction consists of low copper (360.1 alloy) aluminum castings, phosphate pretreatment, UL listing Extends ballast and capacitor life 100% if operated in 25°C (77°F) average ambients. BRIDGES PAPER MILLS POWER PLANTS PETROCHEMICAL PLANTS WASTEWATER FACILITIES BUILDING FACADES PARKING LOTS OUTDOOR SECURITY Application versatility Normal environment - UL/ CUL 1598 • Protected HPS starter Protects starter and ballast from damage when lamp fails. • Mounting versatility 360° yoke for 100% flexibility. Knuckles for 2 and 4 inch tenons. Junction box mount. • Stainless steel exposed hardware Provides long useful life in harsh locations. • Low Energy Use Holophanemanufactured ballasts provide highest lamp wattage with lowest input watts. Optional low loss ballasts in 250 – 400W MH reduce losses by an additional 10 to 20 watts per fixture. • “Suitable for Wet Locations” Harsh environment - UL 844 • Class I, Division 2 • Class II, Division 1 & 2 (small Predator only) • Class III, Division 1 & 2 (small Predator only) • CSA Certified UL 1598A* • Marine Outside *There are 4 levels of marine listings defined by UL 1598A, with Marine Outside having the most severe requirements. ® PREDATOR ® PREDATOR Predator “CI” Fixtures Class I, Division 2 Groups A, B, C, D Hazardous Locations Predator has been designed and tested in accordance with UL Standard 844. Therefore, it complies with Article 501.9(B) (2) of the National Electrical Code, specifically, “tested in order to determine the marked operating temperature or temperature range.” Predator “CII” Fixtures Class II, Division 1 & 2 Groups E, F, G Class III, Division 1 & 2 Hazardous Locations Predator has been designed and tested in accordance with UL Standard 844 to be “dust-ignitionproof” as required for Class II applications. The fixture will exclude dust from the inside of the enclosure and will function at full rating without developing surface temperatures high enough to cause excessive dehydration or gradual carbonization of any organic dust deposits that may build up. Maximum surface temperatures will not exceed 200°C (392°F) Group E and Group F or 165°C (329°F) Group G under normal conditions of use. All temperature classifications are for 40°C ambient temperature. Table 1 lists the UL tested maximum operating temperatures for lamp type and wattage based on operation in the specific ambient for which it is approved. Please refer to the Maximum Surface Temperature Code Table of the NEC. Table 1 Predator Temperature Classification for Class I, Division 2, Hazardous Locations and Class II, III, Division 1 & 2, Hazardous Locations. Lamp Type & Wattage Class I, Division 2 Maximum Mounting Temp. °C Code Restriction 50W HPS 70W HPS 100W HPS 150W HPS 55V 150W HPS 100V 250W HPS 400W HPS 175W MH 250W MH 400W MH 100W MV 175W MV 250W MV 400W MV 163 178 221 272 244 323 388 306 347 347 247 313 383 383 1 2 3 4 T3B T3A T2C T2A T2B 325* T1 325* 350* 350* T2B 325* T1 T1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Lamp Type & Wattage Class II, III, Divisions 1 & 2 Maximum Temp. °C Group Code Mounting Restriction 50W HPS 70W HPS 100W HPS 150W HPS 55V 150W HPS 100V 150W HPS 100V 175W MH 175W MH 100W MV 175W MV 163 178 221 272 244 244 306 306 247 313 2 2 2 3 3 4 3 4 2 2 E,F,G E,F,G E,F,G E,F,G E,F E,F,G E,F E,F,G E,F,G E,F T4A T3C T3C T3C T3A T3B T3 T3C T3C T3 Mounting restricted to lamp vertical, base down, +/- 90°. Mounting restrictions are referenced to lamp vertical, base down, 25° back of vertical to 90° lens down. Mounting restrictions are referenced to lamp vertical, base down, vertical to 90° lens down. Mounting restrictions are referenced to lamp vertical, base down, 90° lens down only. * UL Standards covering hazardous locations (UL 844) Paragraph 49.10 permits fixtures under Class I, Division 2, which are between 300°C and 450°C to be marked with 325, 350, 375, 400, 425, 450 to indicate actual maximum temperature. (e.g. Code 325 = 325°C) Note: Maximum temperatures for lamp type and wattage vary between Class I and Class II & III. Class I is established based upon the maximum temperature inside or outside the luminaire. Class II and III maximum temperature is based upon external surface temperature. Class III fixtures will exclude fibers or flyings from the inside of the enclosure and will function at full rating without developing surface temperature high enough to cause excessive dehydration or gradual carbonization of accumulated fibers or flyings. NEC Requirements — UL Standard 844, File no. E12267 Performance Specification Table 2. Photometric Data Source Watts HPS 50 70 100 150 250 400 MH 175 250 400 DX MV 250 400 1 2 Vertical Distribution Narrow Wide Narrow Wide Narrow Wide Narrow Wide Spot Narrow Wide Spot Narrow Wide Spot Narrow Wide Spot Narrow Wide Spot Narrow Wide Spot Narrow Wide Spot Narrow Wide Spot NEMA Beam1 7x5 7x7 7x5 7x6 7x5 7x6 7x6 7x6 4x4 7x4 7x6 6x4 7x5 7x6 6x5 7x5 7x6 4x4 7x4 7x6 6x4 7x4 7x6 5x4 7x7 7x7 6x6 7x7 7x7 6x7 Beam Total Max. Efficiency2 Efficiency Candela 64.2% 69.4% 63.4% 68.7% 64.3% 68.0% 65.3% 67.6% 47.8% 66.6% 70.1% 64.7% 67.0% 69.6% 64.6% 65.5% 70.9% 51.4% 59.2% 72.2% 56.6% 64.1% 71.4% 59.5% 67.4% 67.0% 66.5% 63.0% 62.5% 64.1% 71.0% 71.7% 70.1% 70.9% 69.5% 70.2% 69.7% 69.9% 72.4% 73.3% 73.4% 75.2% 72.3% 72.8% 74.5% 73.2% 73.4% 80.3% 74.9% 75.9% 77.8% 76.2% 75.7% 79.0% 69.0% 68.3% 71.6% 64.6% 64.0% 68.0% Photometric Test # 3172 1898 4556 2595 6264 4117 9658 6358 29994 20075 13852 25719 29653 22441 42203 10834 5527 23696 19769 11815 24413 32262 19407 43500 4981 4440 7066 7126 6513 11106 36339.IES 36363.IES 36337.IES 36361.IES 36335.IES 36359.IES 36333.IES 36347.IES 37019.IES 37199.IES 37200.IES 37198.IES 37196.IES 37191.IES 37197.IES 36343.IES 36367.IES 42320.IES 37218.IES 37219.IES 37217.IES 37202.IES 37201.IES 37203.IES 37224.IES 37225.IES 37223.IES 37208.IES 37207.IES 37209.IES NCHA beam based on field angle Beam efficiency based on field angles.Field angles are used because they more accurately represent lumens in beam Fixture shall be Holophane catalog number . Mechanical Construction: The housing shall be die cast low copper (360.1 alloy) aluminum finished with a 7-stage pretreatment and an electrostatically applied 2 - 4 mil coat of polyester powder paint. The finish shall withstand a 160 inch-pound impact measured with a standard Gardner Impact Tester. It shall have passed a 1000 hour salt spray test as specified by ASTM B-117. It shall exhibit no cracking or loss of adhesion from a 180° bend over a 1/8 inch mandrel diameter per ASTM D522. All external screws shall be captive and be Type 316 stainless steel. The yoke shall be either AISI Type 316 stainless steel or zinc electroplated and yellow chromate finished cold rolled steel. The yoke shall be capable of being rotated 360° about the fixture for top, bottom, or back mounting. The door shall be hinged to provide easy access during lamping and shall be secured to the fixture while open. The door assembly shall include mechanical stops to assure proper compression of the gasket. The yoke mounted fixture shall have a threaded entry to accommodate 1/2” NPT conduit or connector. When the junction box mount fixture is used, a 1” NPT entry shall be provided. Water-tightness: No water shall enter the fixture when exposed to a solid stream of water from 3 GG40 brass spray nozzles - each supplying 12 gallons per minute at 100 PSI. The nozzles shall be 30 inches apart, centered on, and 24 inches from the fixture plane. Three tests shall be conducted for 15 minutes each with the vertical distance of the fixture at 6, 12, and 16 inches above the nozzles. The gasket shall be hollow core, Durometer 60 silicone, and have a 200°C continuous service temperature. It shall have demonstrated no visible deterioration after artificial aging for 96 hours in oxygen at a pressure of 300 pounds per square inch at a temperature of 156° F. Dust-tightness: An enclosure of a fixture for Class II locations shall be exposed for at least six heating and cooling cycles and for at least 30 hours to a circulating dust-air atmosphere to determine that the fixture is dust-ignition-proof with regard to exclusion of dust. There shall be no entrance of the dust into the device as determined by visual examination following the chamber test described. The fixture is to be installed in a test chamber to permit free circulation of the dust-air mixture around the fixture. The test chamber is to be provided with a cover and with dust-air-inlet and outlet connections. The fixture is to be exposed to the dust-air atmosphere that is to be produced by auxiliary apparatus and introduced into the test chamber. The tests are to be conducted at an ambient temperature of 10-40°C (50-104°F) and a relative humidity of 40-60 percent. Grain dust consisting of wheat or com dust, or both, that has passed through a U.S.A. Standard 150-micron (100-mesh) wire cloth is to be used for the dust-air atmosphere if the fixture is for Class II, Group F, Group G, or Groups F and G locations. Magnesium dust, all of which has passed through a U.S.A. Standard 250-micron (60 mesh) wire cloth, 66 percent of which has passed through a 150-micron (100-mesh) wire cloth, and 22 percent of which has passed through a 75-micron (200-mesh) wire cloth, is to be used for the dust-air atmosphere if the fixture is for Class II, Group E, Groups E and F, Groups E and G, or Groups E, F, and G locations. Quick Disconnect Electrical: The fixture door shall contain all ballast components, including the socket, and be designed for fast removal as a complete assembly without disturbing aiming. The fixture shall be capable of being changed to a different wattage, voltage, or lamp source by simple change out of the unitized electrical assembly. Replacement shall take less than 60 seconds. Optical and Socket Assembly: The reflector shall consist of high purity alloy #3002 aluminum of minimum 0.08 thick sheet. Lens shall be 4.5 mm minimum thickness tempered glass. The beam efficiency shall be no less than ___*___. The total efficiency shall be no less than ____*___. Lamp holders shall be porcelain with high temperature 16 ga. wiring. Sockets shall be pulse rated. The screw shell shall be nickel-plated brass with anti-vibration grips. Ballast: Shall be copper wound, high power factor, Lead or Low Loss Lead as specified. Ballasts shall reliably start and operate the lamp in ambient temperatures to minus 40° F. The lamp extinguishing voltage shall be as low as 39% of nominal. Ballast shall provide 100% wattage to the lamp and have a published Ballast Factor of 1.0 per ANSI C82.2. The fixture shall be UL listed for 40° C. When operated at 10° C below rated ambient temperature, ballast insulation and capacitor life shall be extended 100%. The low loss ballast available for 250 – 400 watt lamps, if specified, shall have a core of grain oriented M-6 steel to reduce ballast losses 10 to 20 watts per fixture. A protected started for High Pressure Sodium lamps, if specified, shall sense an inoperative lamp and automatically shut down to prevent continuous pulsing and thermal damage to itself and ballast secondary windings. Warranty: The electrical assembly shall be warranted for a period of 5 years and the luminaire for a period of 2 years from the date of shipment. Listing: The fixture shall be UL/CUL 1598 listed for 40° C ambient “Suitable for Wet Location.” It shall be UL 844 listed for Class I, Division 2; Class II, Division 1 & 2; Class III, Division 1 & 2. It shall be UL 1598A listed for Marine Outside. *Note: See Table 2 for applicable beam efficiency and total efficiency. ® PREDATOR ® PREDATOR¤ Low copper (360.1 1alloy)Housing: die cast aluminum with 1 3 polyester powder paint. Mounting: 360° swivel of 2mounting yoke around fixture provides top, bottom, or back mounting. 2 Unique reflector 3designReflector: eliminates bright streaks, provides uniform illumination, and low surface brightness. 5 4 Tempered glass lens removable 5door:Quick-disconnect Includes all electrical 4 components, including the socket. Captive stainless steel screws. Door does not distort when fastened. 6 Gasket: Hollow core high temperature silicone gasket. 6 Mounting versatility Since the yoke can rotate 360° around the fixture, the Predator can be mounted from below, above, or any intermediate position. An optional knuckle fitter, adjustable in 5° increments, can be ordered in lieu of the yoke, or a slip fit adaptor can be supplied as an accessory to the yoke for mounting on a 2" tenon. For ceiling mounting in tunnels or back mounting for sign lighting, a box mount can be supplied in lieu of the yoke to give a 15° tilt from the mounting plane. The knuckle fitter, junction box, and slip fit adaptor options are not suitable for hazardous locations. 08657 2" Tenon pole adaptor Junction box mount Knuckle fitter Mounting Options Ordering Data How to construct a catalog number for Predator Fixture type_____________________________ EXAMPLE: PD — 050HP — 12 — H — N — 3 1 Catalog no. 2 3 Luminaire type 2 Source and wattage 3 PD __ 050HP __ 070HP __ 100HP __ 15AHP __ 175MH PF __ 250HP __ 25LHP __ 400HP __ 40LHP __ 250MH __ 25LMH __ 40LMH __ 250MV __ 400MV 6 — PS 7 8 Small Predator (UL 844, UL 1598A, UL/CUL 1598, 40°C wet location) Medium Predator (UL 844 and UL/CUL 1598, 40°C wet location) 50W HPS (120 volt only) 70W HPS 100W HPS 150W/55V HPS 175W MH 250W 250W 400W 400W 250W 250W 400W 250W 400W H HPS HPS, energy saving HPS HPS, energy saving MH MH, energy saving MH, energy saving MV MV W D 2X 10.7mm (.422”) (2) clearance holes for mounting bolts __ 12 __ 20 __ 24 __ 27 __ 34 __ 48 __ MT 120 volt 208 volt 240 volt 277 volt 347 volt (Canada only) 480 volt Multi-voltage (120 - 277 volt USA) NA with 050HP, 250 and 400MV Vari-tap (120, 277, 347 volt) Only available with 250HP, 250 MH, 400HP UL/CUL listing PD __ H __ J __ K __ L PF __ B __ K __ L Class I only (UL 844) Class I, II, III, and marine outside (UL 844) Wet location (UL/CUL 1598) Marine outside (UL 1598A) Class I (UL 844), and marine outside (UL 1598A) Wet location (UL/CUL 1598) Marine outside (UL 1598A) 5 Optical 6 Mounting 7 Color 8 Options and accessories __ N __ W __ S __ 1 __ 2 __ 3 __ 4 __ 5 __ G __ B __ K __ W Protractor markings every 15° for a 180° total 2 places Clearance holes for luminaire mounting Voltage __VT 4 5 Description 1 __ PD __ PF 4 — G 63.5mm (2.5”) 31.8mm (1.25”) 25mm (1.0”) 51mm (2.0”) (1) 13.5mm (.53”) hole for wiring Predator PD PF W H D 13.125” 17.875” 7.875” 16.875” 22.75” 10.5” Effective Projected Area (In Ft2) Tilt above Small Predator Nadir EPA 15° 1.14 45° 1.66 90° 1.93 135° 1.70 180° 1.14 Weight 20-23 lbs. 39-46 lbs. Medium Predator EPA 1.86 2.66 2.87 2.45 1.61 Narrow vertical, wide horizontal beam Wide vertical, wide horizontal beam Spot distribution (UL/CUL 1598 & UL 1598A on PD only ) 2” Knuckle fitter (UL/CUL 1598 only) Box mount (UL/CUL 1598 and UL 1598A only) Stainless steel yoke Zinc plated yoke (UL/CUL 1598 only) 4” Knuckle fitter (UL/CUL 1598 only) Gray Bronze Black (UL/CUL 1598 on PF only) White (UL/CUL 1598 on PF only) See page 8 Order number ___________________ Job name ___________________ ® PREDATOR Options and Accessories Wire guard Visor Visor & side shield Catalog no. Options (factory installed) __ A __ C __ D __ E __ F __ H __ L __ J __ PS __ R1 _ TB1 Gray top visor Bronze top visor Gray side shield (UL/CUL 1598 only) Bronze side shield (UL/CUL 1598 only) Black top visor (UL/CUL 1598 on PF only) White top visor (UL/CUL 1598 on PF only) Black side shields (UL/CUL 1598 on PF only) White side shields (UL/CUL 1598 on PF only) Protected starter for HPS units only Photocontrol receptacle (NEMA twistlock) (UL/CUL 1598 on PF only) Terminal block Accessories (shipped separately) __ LAMP Ship appropriate lamp as line item __ F1 Single fuse assembly for 120, 240, 277, or 347 volt (UL/CUL 1598 only) __ F2 Double fuse assembly for 208, 240, or 480 volt (UL/CUL 1598 only) __ PDWG Wire guard for “PD” unit __ PFWG Wire guard for “PF” unit __ PDPR12 120V photocontrol (UL/CUL 1598 only) __ PDPR 208, 240, 277V photocontrol (UL/CUL 1598 only) __ PDPR34 347V photocontrol __ 08657-xx2 2” tenon pole adapter (UL/CUL 1598 only) Notes: 1 Contact TSG 2 Insert GR-Gray, BZ-Bronze, BK-Black, WA-White for “xx” in catalog number Acuity Lighting Group, Inc. 214 Oakwood Ave., Newark, OH 43055 / Holophane Canada, Inc. 9040 Leslie Street, Suite 208, Richmond Hill, ON L4B 3M4 / Holophane Europe Limited, Bond Ave., Milton Keynes MK1 1JG, England / Holophane, S.A. de C.V., Apartado Postal No. 986, Naucalpan de Juarez, 53000 Edo. de Mexico Contact your local Holophane factory sales representative for application assistance, and computer-aided design and cost studies. For information on other Holophane products and systems, call the Inside Sales Service Department at 740-345-9631. In Canada call 905-7075830 or fax 905-707-5695. Limited Warranty and Limitation of Liability Refer to the Holophane limited material warranty and limitation of liability on this product, which are published in the “Terms and Conditions” section of the current product digest, and is available from our local Holophane sales representative. Visit our web site at www.holophane.com