Rig-A-Lite LED Luminaire Guide Superior LED Technology for Hazardous and Severe Environments Five-Year Warranty Rig-A-Lite LED Luminaires The Rig-A-Lite LED luminaires are the perfect combination of dependability, safety and energy efficiency for facilities including hazardous and severe environments. Since 1938, we have been at the forefront of lighting technology, providing industry with intelligent solutions to their lighting dilemmas. As LED technology has continued to improve, Rig-A-Lite has integrated it into our vision of the future of lighting these specialty environments including petrochemical refining, petroleum refining, waste water treatment facilities, pharmaceutical facilites, food processing facilities, power plants and other industrial & manufacturing areas where flammable vapors, gasses, ignitable dusts, fibers or flyings are present. Our LED product series are also rated for marine environments, wet locations and heavy hose-down applications- indoors or outdoors. Compared to HID (high intensity discharge) technologies, LED (light emitting diode) technology provides extended life expectancy, greater energy effeciency and reduced maintenace costs with a comparable or better quality of light. Highly efficient LED drivers provide current regulation for consistent performance in severe environments. LED arrays also provide consistent, energy efficient and long life output. Our die cast aluminum and acrylic housings allow for efficient heat sink and UL listed/ NEMA rated protection in a traditional style that the industry is familiar with. All of our LED luminaires are fully retrofittable in the field, allowing our customers to grow with the technology while minimizing the cost of doing so. Photometric performance of LED luminaires is evolving quickly. We have made every effort to accurately describe the actual performance of our luminaires and will incorporate new technologies to assure maximum performance and energy savings as they are available. We will continue our commitment to quality by providing a five year warranty against manufacturing defects on all LED luminaires. 2 XPEX Series LED Features •Explosion Proof LED Exit Light •Red or green legend •Single or dual panel edge lit design •LED light source- 25 year life expectancy •Maximum 3 watts power consumption •Fully integrated electronic circut board and components •Integrated battery backup option with three hour operation •Emergency fixtures meet or exceed NFPA 70 and NFPA 101 standards •Energy Star rated •Factory sealed •Custom colors available •Custom legends available Certifications •Class I, Division 1, Groups C & D •Class II, Division 1 & 2, Groups E, F & G •Class III •Class I, Zone 1, Groups IIA, IIB •Zone 2, Groups IIA & IIB + H2 & IIC •UL 1598A Marine Outside Type •UL 844, 8750 & 924 •IP65 •Temperature Class (T-Rating)- T6 •Patent Number 7,287,347 Standard Materials •Copper Free Cast Aluminum Alloy Housing •Epoxy Powder Coated •Wall/Pendant or End Mount Configurations •Acrylic Lens Certification Guide Model Legend XPEX XPEX Green Red Ambient Class II, Div. 1, Temperature Class I, Div. 1, Groups E, F, G, °C Groups C, D Class III 40 T6 T6 55 T6 T6 Simultaneous Presence Class I & Class II T6 T6 Class I, Zone 1, Groups IIA, IIB T6 T6 UL1598A Outdoor YES YES 3 XPEX Series LED Catalog Number Logic XPEX-2-G-DT-WP-XX 1 1 2 2 BASIC SERIES XPEX Explosion Proof LED Exit Light Class I, Division 1, Groups C, & D Class II, Division 1 Groups E, F & G Class III Class I , Zone 1, Groups IIA, IIB, Zone 2, Groups IIA, IIB + H2 & IIC Marine Outside Type UL 1598A, 8750, 844, 924 IP65 Temperature Class (T-Rating)-T6 NUMBER OF FACES 1 = Single Face 2 = Double Face 3 4 5 3 4 6 LEGEND COLOR R = Red G = Green VOLTAGE/FREQUENCY DT = 120/277V 60HZ 24 = 220-240V 50/60HZ Other voltages available- consult factory 5 MOUNTING WP = Wall/Pendant Mounting EB =End Bracket 6 OPTIONS1 EM=Emergency Battery Backup EU=Green Running Man Exit Legend SD= Self Diagnostics X = Exit Legend in Other Languages Language Must Be Specified 1Consult factory for pricing. Operating Temperature Range Temperature Rating- T6 Red Legend Green Legend +10° C Minimum to +55° C Maximum +10° C Minimum to +40° C Maximum Battery Wattage Red without battery- 1.5 Watts Red with battery- 2.5 Watts Green without battery- 2.3 Watts Green with battery- 3 Watts 4 XPS Series LED Features •Explosion Proof LED Multipurpose Sign Light •Red or green legend •Single or dual panel edge lit design •LED light source- 25 year life expectancy •Maximum 3 watts power consumption •Fully integrated electronic circut board and components •Integrated battery backup option with three hour operation •Emergency fixtures meet or exceed NFPA 70 and NFPA 101 standards •Energy Star rated •Factory sealed •Custom colors available •Custom legends available Certifications •Class I, Division 2, Groups A, B, C & D •Class II, Division 2, Groups F & G •Class III •UL 1598A Marine Outside Type •UL 844, 8750 & 924 •ETL Listed •IP65 •Temperature Class (T-Rating)- T6 •Patent Number 7,287,347 Standard Materials •Copper Free Cast Aluminum Alloy Housing •Epoxy Powder Coated •Wall/Pendant or End Mount Configurations •Acrylic Lens Certification Guide Model Legend XPS XPS Green Red Ambient Temperature °C 40 40 Class I, Div. 1, Groups C, D T6 T6 Class II, Div. 1, Groups E, F, G, Class III T6 T6 Simultaneous Presence Class I, Zone 1, UL1598A Class I & Class II Groups IIA, IIB Outdoor T6 T6 YES T6 T6 YES 5 XPS Series LED Catalog Number Logic XPS-2-G-DT-WP-XX 1 1 2 2 3 BASIC SERIES XPS Explosion Proof LED Exit Light * *Customer must specify sign color and legend Class I, Division 1, Groups C, & D Class II, Division 1 Groups E, F & G Class III Class I , Zone 1, Groups IIA, IIB, Zone 2, Groups IIA, IIB + H2 & IIC Marine Outside Type UL 1598A, 8750, 844, 924 IP65 Temperature Class (T-Rating)-T6 NUMBER OF FACES 1 = Single Face 2 = Double Face 4 5 6 3 LEGEND COLOR A = Amber B = Blue R = Red G = Green X = Other (Consult Factory) 4 VOLTAGE/FREQUENCY DT = 120/277V 60HZ 24 = 220-240V 50/60HZ Other voltages available- consult factory 5 MOUNTING WP = Wall/Pendant Mounting EB =End Bracket 6 OPTIONS1 EM=Emergency Battery Backup X = Specify Legend (Cannot Say EXIT) Language Must Be Specified 1Consult factory for pricing. Operating Temperature Range Temperature Rating- T6 Red Legend Green Legend +10° C Minimum to +55° C Maximum +10° C Minimum to +40° C Maximum Battery Wattage Red without battery- 1.5 Watts Red with battery- 2.5 Watts Green without battery- 2.3 Watts Green with battery- 3 Watts 6 SXPJ Series LED Features •Glare Free Performance •Replaces up to 250 watt Metal Halide and 250 watt High Pressure Sodium •60,000 or more hours rated lamp life with 70% lumen maintenance •Constant Current •120-277V 50/60Hz •55º C Maximum Ambient Temperature •Line Transient Protection: 4 KV line to line 2 KV line to ground Certifications •Class I, Division 1, Groups C & D •Class II, Division 1, Groups E, F & G •Class I, Zone I, Groups IIA & IIB •Class III •Factory Sealed •NEMA 3, 4, 4X & 7CD •UL 1598, 1598A, 8750, & 844 •Tested to LM79 & LM80 standards Standard Materials Mounting Options •Copper Free Cast Aluminum Alloy Housing •Baked Epoxy Powder Coating •Stainless Steel External Hardware •Prismatic Tempered Glass Globe •Stainless Steel Guard •Silicone Gaskets •Stanchion •Wall •Ceiling •Pendant •Trunnion Certification Guide Lamp Rated Ambient °C Catalog # SXPJ10L SXPJ10L Type Watts LED LED 98 98 Class I, Groups C & D, Class 1, Zone 1, Groups IIA, IIB, & IIC Mounts Pendant, Wall or Ceiling 40 55 85 (T6) 85 (T6) Class II, Groups E, F & G Class III Mounts Trunnion or Stanchion 85 (T6) 85 (T6) Pendant, Wall, Ceiling or Stanchion only 85 (T6) --- Supply Wire Temperature Rating, Minimum °C 90 90 7 Catalog Number Logic SXPJ 10-L-U-GG-P-XX 1 1 BASIC SERIES Class I, Division 1, Groups C & D Class II, Division 1, Groups E, F & G* Class III Class I, Zone 1, Groups IIA & IIB Factory Sealed UL 1598, 1598A, 8750 & 844 NEMA Type 4X, IP66 Tested to IESNA LM79 & LM80 standards 2 3 4 5 5 6 * Except Trunnion Mount 2 LAMP TYPE 10=98 Watt (LED Only) 3 LAMP CURRENT/LAMP WATTAGE L=LED 4 BALLAST VOLTAGE U=120-277V 50/60HZ 7 6 7 GLOBE & GUARD GG = Globe and Guard G = Globe only MOUNTING STYLE P = 3/4" Pendant Mount P1 = 1" Pendant Mount C = 3/4" Ceiling Mount C1 = 1" Ceiling Mount W = 3/4" Wall Mount W1 = 1" Wall Mount S = 1-1/4" Stanchion Mount S1 = 1-1/2" Stanchion Mount T = Trunnion Mount OPTIONS¹ FB = Fuse Block ² ³ 1Consult factory for pricing. Please specify voltage. When installed, one fuse block is provided for 120 & 277v and two fuse blocks are provided for 208 & 240v. 3Fuse option not available for marine listed fixtures. 2 Catalog logic is for explaining number structure only. Not all combinations are possible. Consult Factory 8 XP Series LED Features Certifications •2, 3 or 4 Lamp Versions •Emergency Battery Backup (2 ft. emergency operation only) •0-10 Volt Dimming Available •Outboard Option Available •60,000 or more hours rated lamp life with 70% lumen maintenance •Factory Sealed •Constant Current •120-277V 50/60Hz •-20º C-55º C Ambient Temperature •Line Transient Protection: 4 KV line to line 6 KV line to ground •Class I, Division 1, Groups C & D •Class II, Division 1, Groups E, F & G •Class III •Factory Sealed •NEMA 3, 4, 4X, 7CD & 9EFG •UL 1598, 1598A, 8750, & 844 •Class I, Zone 1, Groups IIA and IIB •Class I, Zone 2, Groups IIA, IIB & IIC •Paint Spray Booth •CUL Pending •IP66 •Tested to LM79 & LM80 standards •Patent Pending Standard Materials •Copper Free Aluminum Alloy Housing •Aluminum Driver Housing •Extruded Aluminum Reflectors •Explosion Proof, Heat Resistant and Impact Resistant Pyrex Tubes Certification Guide Model Ambient Temperature (°C) Class I, Div. 1, Groups C, D Class II, Div. 1, Groups E, F, G, Class III XP30L22LU XP40L23LU XP50L42LU XP75L43LU XP100L44LU 55 55 55 55 55 T6 T6 T6 T6 T6 T4A T5 T4A T5 T4A Simultaneou s Presence UL1598A Outdoor Class I & Class II T4A YES T5 YES T4A YES T5 YES T4A YES PAINT SPRAY BOOTH YES YES YES YES YES 9 LED XP Series Explosion Proof • Paint Spray Booth • UL 844 • UL 1598A Marine Outside Type • Factory Sealed XP Series LED Catalog Number Logic XP 75L- 4 -3L-U -XX 1 1 2 2 BASIC SERIES XP LED FIXTURE Class I, Division 1, Groups C & D Class II, Division 1, Groups E, F & G Class III Simultaneous Presence NEMA 3, 4X, 7CD, 9EFG UL 1598, UL 1598A, UL 844 & UL 8750 CUL Pending IP66 55°C Ambient Temperature Class I, Zone 1, Groups IIA & IIB Class I, Zone 2, Groups IIA, IIB & IIC Suitable for Inside Paint Spray Booth Patent Pending Tested to LM 79 & LM 80 3 5 4 3 6 NOMINAL FIXTURE LENGTH 2 = 2 Foot 4 = 4 Foot 4 NUMBER OF LAMPS 2L = 2 Tubes 3L = 3 Tubes 4L = 4 Tubes 5 VOLTAGE/FREQUENCY U = 120 thru 277V 50/60 HZ 6 OPTIONS1 EM = Emergency Battery Backup Pending D = Dimmable (0-10 Volt) F = Inline Fuse (External)2 OB = Out Board Option 35 = 3500K (CCT) 50 = 5000K (CCT) LAMP CURRENT/LAMP WATTAGE 30L = 30 Watt LED (2 ft. 2 tube) 40L = 40 Watt LED (2 ft. 3 tube) 50L = 46 Watt LED (4 ft. 2 tube) 75L = 73 Watt LED (4 ft. 3 tube) 100L = 93 Watt LED (4 ft. 4 tube) 1 2 Consult factory for pricing. Fuse option not available for marine listed fixtures. Catalog logic is for explaining catalog number structure only. Not all combinations are possible; consult factory for catalog numbers not listed in charts. www.rigalite.com 10 11 HLEX Series LED Features •Hazardous Location LED Exit Sign •Red or green legend •Single or dual panel edge lit design •LED light source- 25 year life expectancy •Maximum 3 watts power consumption •Fully integrated electronic circut board and components •Integrated battery backup option with three hour operation •Emergency fixtures meet or exceed NFPA 70 and NFPA 101 standards •Energy Star rated •Factory sealed •Custom colors available •Custom legends available Certifications •Class I, Division 2, Groups A, B, C & D •Class II, Division 2, Groups F & G •Class III •UL 1598A Marine Outside Type •UL 844, 8750 & 924 •ETL Listed •IP65 •Temperature Class (T-Rating)- T6 •Patent Number 7,287,347 Standard Materials •Copper Free Cast Aluminum Alloy Housing •Epoxy Powder Coated •Wall/Pendant or End Mount Configurations •Acrylic Lens Certification Guide Model HLEX HLEX Class II, Div. 1, Class I, Div. 1, Groups E, F, G, Ambient Legend Temperature °C Groups C, D Class III Green 40 T6 T6 Red 55 T6 T6 Simultaneous Presence Class I & Class II T6 T6 Class I, Zone 1, UL1598A Groups IIA, IIB Outdoor T6 YES T6 YES 11 HLEX Series LED Catalog Number Logic HLEX-2-G-DT-WP-XX 1 1 2 2 3 BASIC SERIES HLEX Hazardous Location Exit Light Class I, Division 2, Groups A, B, C, & D Class II, Division 2, Groups F & G Class III UL 1598A Marine Outside Type UL 844, 8750, 924 IP65 ETL Listed Temperature Class (T-Rating)-T6 NUMBER OF FACES 1 = Single Face 2 = Double Face 4 5 6 3 LEGEND COLOR R = Red G = Green 4 VOLTAGE/FREQUENCY DT =120/277V 60HZ 24 = 220-240V 50/60HZ Other voltages available- consult factory. 5 MOUNTING WP = Wall/Pendant Mounting EB =End Bracket 6 OPTIONS1 EM = Emergency Battery Backup EU = Green Running Man Exit Legend SD = Self Diagnostics X = Exit Legend in Other Languages Language Must Be Specified 1Consult factory for pricing. Operating Temperature Range Temperature Rating- T6 Red Legend Green Legend +10° C Minimum to +55° C Maximum +10° C Minimum to +40° C Maximum Battery Wattage Red without battery- 1.5 Watts Red with battery- 2.5 Watts Green without battery- 2.3 Watts Green with battery- 3 Watts 12 HLS Series LED Features •Hazardous Location LED Multipurpose Sign Light •Red or green legend •Single or dual panel edge lit design •LED light source- 25 year life expectancy •Maximum 3 watts power consumption •Fully integrated electronic circut board and components •Integrated battery backup option with three hour operation •Emergency fixtures meet or exceed NFPA 70 and NFPA 101 standards •Energy Star rated •Factory sealed •Custom colors available •Custom legends available Certifications •Class I, Division 2, Groups A, B, C & D •Class II, Division 2, Groups F & G •Class III •UL 1598A Marine Outside Type •UL 844, 8750 & 924 •ETL Listed •IP65 •Temperature Class (T-Rating)- T6 •Patent Number 7,287,347 Standard Materials •Copper Free Cast Aluminum Alloy Housing •Epoxy Powder Coated •Wall/Pendant or End Mount Configurations •Acrylic Lens Certification Guide Model Legend HLS HLS Green Red Ambient Temperature Class I, Div. 1, °C Groups C, D 40 T6 55 T6 Class II, Div. 1, Groups E, F, G, Class III T6 T6 Simultaneous Presence Class I & Class T6 T6 Class I, Zone 1, Groups IIA, IIB T6 T6 UL1598A Outdoor YES YES 13 HLS Series LED Catalog Number Logic HLS-2-G-DT-WP-XX 1 1 2 2 3 4 5 6 BASIC SERIES HLS Hazardous Location LED Multipurpose Sign Light* * Customer must specify sign color and legend Class I, Division 2, Groups A, B, C, & D Class II, Division 2, Groups F & G Class III UL 1598A Marine Outside Type UL 844, 8750, 924 IP65 ETL Listed Temperature Class (T-Rating)-T6 3 LEGEND COLOR A = Amber B = Blue R = Red G = Green X = Other (Contact Factory) 4 VOLTAGE/FREQUENCY DT = 120/277V 60HZ 24 = 220-240V 50/60HZ Other voltages available- consult factory. NUMBER OF FACES 1 = Single Face 2 = Double Face 5 6 MOUNTING WP = Wall/Pendant Mounting EB =End Bracket OPTIONS1 EM=Emergency Battery Backup X = Specify Legend (Cannot Say EXIT) 1Consult factory for pricing. Operating Temperature Range Temperature Rating- T6 Red Legend Green Legend +10° C Minimum to +55° C Maximum +10° C Minimum to +40° C Maximum Battery Wattage Red without battery- 1.5 Watts Red with battery- 2.5 Watts Green without battery- 2.3 Watts Green with battery- 3 Watts 14 SAFR Series 75 Watt LED Features Certifications Mounting & Lens Options Standard Materials •Glare Free Performance with threaded and frosted refractors •Replaces up to 100 watt Metal Halide and 100 watt High Pressure Sodium •60,000 or more hours rated lamp life with 70% lumen maintenance •Constant Current •120-277V 50/60Hz •347/480V 60Hz •Junction Temperature: 97º C in a 55º C Ambient •Line Transient Protection: 1 KV line to line. 1 KV line to ground Mounting Styles Include •Stanchion (25° & 90°) •Wall •Ceiling •Pendant •Flexible Pendant •Cone Lens Options Include •Type V Refractor •Low Profile Clear Globe* •Low Profile Frosted Globe* •Class I, Division 2, Groups A, B, C & D •Class II, Division 1, Groups E, F & G •Class III •Class I, Zone 2, Groups IIA, IIB & IIC •Simultaneous Presence •Enclosed and Gasketed •NEMA 3R, 4X •UL 8750,1598,1598A & 844 •CUL •IP 66 •AEx nR II, T4 •Tested to LM79 & LM80 standards •Copper Free Cast Aluminum Alloy Housing •Epoxy Powder Coated •Stainless Steel Hardware •Tempered Glass Globe •Stainless Steel Guard •Silicone Gaskets * Patent # D637339S Certification Guide Class I, Div.2 CLASS Il & lll MODEL AMBIENT °C Groups A,B,C & D GROUPS SAFR09L SAFR09L 40 55 T4A T4A E,F,G E,F,G Simultaneous Presence Class I, Zone 2 UL 1598A OUTDOOR T6 T6 T3C T3C YES YES AEx nR II T4 T4 CUL SUPPLY WIRE SUITABLE TEMP °C YES YES 90 105 15 SAFR Series 98 Watt LED Features Certifications Mounting & Lens Options Standard Materials •Glare Free Performance with threaded and frosted refractors •Replaces up to 175 watt Metal Halide and 150 watt High Pressure Sodium •60,000 or more hours rated lamp life with 70% lumen maintenance •Constant Current •120-277V 50/60Hz •347/480V 60 Hz •Line Transient Protection: 4 KV line to line. 2 KV line to ground •Class I, Division 2, Groups A, B, C & D •Class II, Division 1, Groups E, F & G •Class III •Class I, Zone 2, Groups IIA, IIB & IIC •Simultaneous Presence •Enclosed and Gasketed •NEMA 3R, 4X •UL 8750,1598,1598A & 844 •CUL •IP 66 •AEx nR II •Tested to LM79 & LM80 standards Mounting Styles Include •Stanchion (25° and 90°) •Wall •Ceiling •Pendant •Flexible Pendant •Cone Lens Options Include •Type V Refractor •Low Profile Clear Globe* •Low Profile Frosted Globe* •Copper Free Cast Aluminum Alloy Housing •Epoxy Powder Coated •Stainless Steel Hardware •Tempered Glass Globe •Stainless Steel Guard •Silicone Gaskets * Patent # D637339 Certification Guide Class I, Div.2 16 CLASS Il & lll MODEL AMBIENT °C Groups A,B,C & D GROUPS SAFR11L SAFR11L 40 55 T3A T3A E,F,G E,F,G Simultaneous Presence CID2 C2 D1 Class I, Zone 2 UL 1598A OUTDOOR T6 T6 T3A T3A YES YES AEx nR II T3 T3 CUL SUPPLY WIRE SUITABLE TEMP °C YES YES 90 105 Catalog Number Logic SAFR 09-L-U -T5G-P-XX 1 1 2 BASIC SERIES SAFR Hazardous Location LED Class I, Division 2, Groups A, B, C & D Class II, Division 1 & 2, Groups E, F & G Class III Simultaneous Presence Class I, Zone 2, Groups IIA, IIB & IIC Enclosed and Gasketed Wet Locations NEMA 3R, 4X; IP66 UL 1598, 1598A, 844 & 8750 CUL ABS Type Approved Restricted Breathing (Annual Testing Not Required) AEx nR II 2 5 3 4 5 6 7 GLOBE & GUARD LC = Low Profile Clear Globe Only LCG = Low Profile Clear Globe & Guard LF = Low Profile Frosted Globe Only LFG = Low Profile Frosted Globe & Guard T5 = Type V (Symmetric) Closed Bottom Glass Refractor T5G = Type V (Symmetric) Closed Bottom Glass Refractor & Guard 6 MOUNTING STYLE P = 3/4" Pendant Mount P1 = 1" Pendant Mount C = 3/4" Ceiling Mount C1 = 1" Ceiling Mount W = 3/4" Wall Mount W1 = 1" Wall Mount S = 1-1/4" 25° Stanchion Mount S1 = 1-1/2" 25° Stanchion Mount L = 1-1/4” 90° Stanchion Mount L1 = 1-1/2” 90° Stanchion Mount K = 3/4" Cone Top K1 = 1" Cone Top 7 OPTIONS1 SS = Stainless Steel Inserts (304) FB1 = Single Fuse Block 2,3 FB2 = Double Fuse Block 2,3 TB = Terminal Block LAMP CURRENT/LAMP WATTAGE 09 = 75 Watt 11 = 98 Watt 1 Consult 3 4 factory for pricing available unless incoming voltage is specified. When installed, one fuse block is provided for 120, 277V and two fuse blocks are provided for 208, 240 and 480V. Fuse not included. Not available on 347V or 480V 3 Fuse option not available for marine listed fixtures. 2 Not LAMP TYPE L = LED DRIVER VOLTAGE U = 120-277V 50/60HZ N = 347/480V 60HZ 17 SAFJ Series LED Features Certifications •Glare Free Performance with frosted globe •Replaces up to 70 watt Metal Halide and 70 watt High Pressure Sodium •60,000 or more hours rated lamp life with 70% lumen maintenance •Constant Current •120-277V 50/60Hz •347/480V 60Hz •Total Efficacy of 72.4 Lm/W with Clear Globe •Line Transient Protection: 4 KV line to line 2 KV line to ground •Class I, Division 2, Groups A, B, C & D •Class II, Division 1 & 2, Groups E, F & G •Class III •Simultaneous Presence •Enclosed and Gasketed •NEMA 3R, 4X •UL 1598A, 8750 •CUL •IP 66 •Tested to LM79 & LM80 standards Mounting & Lens Options •Copper Free Cast Aluminum Alloy Housing •Epoxy Powder Coated •Stainless Steel Hardware •Tempered Glass or Polycarbonate Clear or Frosted Globe •Stainless Steel Guard •Silicone Gaskets Mounting Styles Include •Stanchion (25° and 90°) •Wall •Ceiling •Pendant •Flexible Pendant Glass and Poly. Lens Options Include •Low Profile Clear Globe* •Low Profile Frosted Globe* Standard Materials * Patent # D637340S Ambient Watts Type Temperature °C Model SAFJ06 SAFJ06 18 45 45 1 2 LED LED 40 55 Supply Class I, Div. 21 Class II, Div. 12 Simultaneous Wire Suitable UL1598A CUL Groups A,B, C, D Class III Presence Temp °C Outdoor T3C T3C T5 (E, F & G) T3A (E & F) T3 T3 105 105 Yes Yes Yes Yes With or without external reflectors (fixtures can be used with or without external reflectors in Class I, Div. 2 areas only). Without external reflectors (use of external reflectors is not permitted for fixtures in Class II environments) SAFJ Series LED Catalog Number Logic SAFJ 06-L-U- LFG-C- X 1 1 2 3 4 2 3 4 BASIC SERIES SAFJ LED Class I, Division 2, Groups A, B, C, & D Class II, Division 1, Groups E, F & G Class III Simultaneous Presence Enclosed & Gasketed Wet Locations UL1598A Marine Outside Type UL 844 Hazardous Locations UL 8750 LED Safety NEMA 3R,4X IP66 CUL ABS Type Approved 5 6 LAMP CURRENT/LAMP WATTAGE 06 = 45 Watt LAMP TYPE L = LED DRIVER VOLTAGE U = 120-277V 50/60HZ N = 347/480V 60HZ 7 5 6 7 GLOBE & GUARD LC = Low Profile Clear GlassGlobe LCG = Low Profile Clear Glass Globe & Guard LPC = Low Profile Clear Polycarbonate LPCG = Low Profile Clear Polycarbonate & Guard LF = Low Profile Frosted Glass Globe LFG = Low Profile Frosted Glass Globe & Guard LPF = Low Profile Frosted Polycarbonate Globe LPFG = Low Profile Frosted Polycarbonate Globe & Guard MOUNTING STYLE P = ¾" Pendant Mount P1 = 1" Pendant Mount C = ¾" Ceiling Mount C1 = 1" Ceiling Mount W = ¾" Wall Mount W1 = 1" Wall Mount S = 1-¼" 25°Stanchion Mount S1 = 1-½" 25°Stanchion Mount L = 1-¼" 90°Stanchion Mount L1 = 1-½" 90°Stanchion Mount OPTIONS1 SS = Stainless Steel Inserts SC = Safety Cable FB1 = Single Fuse Block FB2 = Double Fuse Block 1Consult factory for pricing. available with universal dirver unless incoming voltage is specified. When installed, one fuse block is provided for 120 & 277V and two fuse blocks are provided for 208, 220, 240, 347 and 480V. Fuse not provided. 3FB option not available for marine listed fixtures. 2Not Catalog logic is for explaining catalog number structure only. Not all combinations are possible; consult factory for catalog numbers not listed in charts. 19 MHDA/MHDS Series LED Features •Hazardous location marine rated LED •Stainless steel mounting brackets •Heavy duty injection molded lens with reinforced corners •Dual stainless steel lens tethers •Ceiling mount or pendant mount options •60,000 or more hours rated lamp life with 70% lumen maintenance •3/4” NPT Aluminum Conduit Hubs •Water tight gasket attached to the lens for superior ingress protection •Line Transient Protection: 4 KV line to line. 2 KV line to ground •Constant Current Certifications •Class I, Division 2, Groups A, B, C & D •Class II, Division 2, Groups F & G •Class III •UL 1598A Marine Outside Type •UL 844, 8750 •Tested to LM79 & LM80 •CSA C22.2 #137 •CSA C22.2 #213 •ETL Listed •55° C Ambient Temperature •IP66 Standard Materials •Copper Free Cast Aluminum Alloy Housing or 304 Stainless Steel- 316 Stainless Steel Option Available •Epoxy Powder Coated White •Captive Stainless Steel Latches •Acrylic Lens- Polycarbonate Option Available Certification Guide Model MHDA/S10L4U 20 Ambient Class II, Div. 2, Class I, Div. 2 Groups Temperature Groups F & G, A, B, C & D °C Class III 55 T4A T4 Supply Wire Suitable Temperature °C 105 MHDA/MHDS Series LED Catalog Number Logic MHDA 10-L- 4 -U-XX 1 1 2 3 4 2 BASIC SERIES MHDA Aluminum LED MHDS Stainless Steel LED Class I, Division 2, Groups A, B, C and D Class II, Division 2 Groups F & G Group III UL 844 Hazardous Locations UL 1598A Marine Outside Type UL 8750 LED Safety CSA C22.2 #137; C22.2 #213 ETL Listed Tested to LM79 & LM80 55° C Ambient Temperature IP66 LAMP CURRENT/LAMP WATTAGE 10 = 80 Watt 3 4 6 5 5 6 VOLTAGE/FREQUENCY U = 120-277V 50/60 HZ OPTIONS1 P = Polycarbonate Lens FB = Fuse Block2 TB = Terminal Block TW = Thru Wire Cable Installations Only PM = Pendant Mount SP = Surge Protector 316 = 316 Stainless Steel Housing 1 Consult factory for pricing. option not available for marine listed fixtures. 2 Fuse LAMP TYPE L = LED NOMINAL FIXTURE LENGTH 4 = Four Foot 21 MAR2 Series LED Features •Hazardous Location Marine Rated LED •Cast Aluminum End Caps •UV Resistant Non-Metallic Hinges •Extruded Aluminum Lens Frame •360° Mounting Flexibility •60,000 or more hours rated lamp life with 70% lumen maintenance •3/4” NPT Aluminum Conduit Hubs •Water tight gasket attached to the lens for superior ingress protection •Line Transient Protection: 4 KV line to line. 2 KV line to ground •Constant Current Certifications •Class I, Division 2, Groups A, B, C & D •UL 1598A Marine Outside Type •UL 844 Hazardous Locations •UL 8750 LED Safety •Tested to LM79 & LM80 •CSA C22.2 #137 •CSA C22.2 #213 •ETL Listed •55° C Ambient Temperature Standard Materials •Copper Free Extruded Aluminum Housing •Stainless Steel Cam Action Latches •Shatter and Heat Resistant Acrylic Lens Certification Guide Supply Ambient Wire Class I, Division 2 Groups Temperature Suitable A, B, C & D °C Model Temp °C MAR210L4U 55 T4A 105 MAR210L2U 55 T4A 105 22 MAR2 Series LED Catalog Number Logic MAR2 10 - L - 4 - U - XX 1 1 2 3 2 BASIC SERIES MAR2 LED Fixture Class I, Division 2, Groups A, B, C & D UL 844 Hazardous Locations UL 1598A Marine Outside Type UL 8750 LED CSA C22.2 #137 CSA C22.2 #213 ETL Listed 55°C Ambient Temperature LAMP CURRENT/LAMP WATTAGE 10 = 80 Watt LAMP TYPE L = LED 3 4 4 5 6 5 6 NOMINAL FIXTURE LENGTH 2 = Two Foot 4 = Four Foot VOLTAGE/FREQUENCY U = 120-277 50/60HZ OPTIONS1 TW = End Mounting/Thru Wire Cable Installations Only F = Single Fuse2 TM = Tempered Glass EB = Eye Bolt Only SC = Safety Cable with Eye Bolt SP = Surge Protector 1Consult 2Fuse factory for pricing. option not available for marine listed fixtures. 23 WFH Series LED Features •Low copper content aluminum minimizes corrosion • Philips LED System •Replaces up to 400 watt Metal Halide •Color Temperature: 4,100 CCT (K) standard. 3,500K and 5,000K •CRI: > 82 •60,000 or more hours rated life expectancy with minimum 70% lumen maintenance •Total Lumens: 148 Watts clear: 14,112 prismatic: 13,090 •Constant Current •120-277V, 50/60Hz or 347/480V, 60Hz •Line Transient Protection: 4 KV line to line, 2 KV line to ground •Standard fixture suitable for freezer applications •Fixture suitable for -20°F (-28°C) to +50°C (+122°F) ambient temperature 24 Certifications •Class I, Division 2, Groups A,B,C,D •Class II, Division 2, Groups F & G •Class III •UL 844 Hazardous Locations •UL 8750 LED Safety •NEMA Type 4X •CUL Listed •NSF Certified Food Equipment •Enclosed and Gasketed •Tested to LM79 & LM80 standards •Hose Down Tested Standard Materials •Continuously welded aluminum construction •FDA accepted powder coated finish •Stainless steel hardware •Extruded silicone lens frame gasket •Hinged reflector assembly WFH Series LED Catalog Number Logic WFH 150- 24 -4S-CA-U- DH-XX 1 1 2 3 4 2 BASIC SERIES WFH LED Hazrdous Location High Bay Class I, Division 2, Groups A,B,C & D Class II, Division 2, Groups F & G Class III UL 844 Hazardous Locations UL 1598 Wet Locations UL 8750 LED Safety CUL NEMA 4X Wash Down Rated Hose Down Tested to 1200psi Fire Hose Tested at 65gpm NSF Certified Food Equipment LED MAXIMUM SYSTEM WATTAGE 150 = 148 Watt LED NOMINAL LUMINAIRE SIZE 24= 2 x 4 Foot NUMBER OF LIGHT STRIPS 4S=4 LED Strips 3 4 5 6 7 5 LENS TYPE CA = Clear Acrylic PA =Prismatic Acrylic 6 VOLTAGE/FREQUENCY U = 120-277V 50/60 HZ N = 347-480V 60 HZ 7 MOUNTING DH=Dual Hub 1/2 in. NPT SH=Single Hub 3/4 in. NPT 8 OPTIONS1 F = Single Fuse- For USL Luminaires Only (For Luminaires Rated 277 VAC or Less) D = Dimmable (0-10 Volt) DF = Double Fuse- For USL Luminaires Only (For Luminaires Rated 277 VAC or Less) HNG = Hinged Lens Frame 35 = 3500K (CCT) 50 = 5000K (CCT) 1 Consult Factory for Pricing Catalog logic is for explaining number structure only. Not all combinations are possible. Consult Factory 25 WFHN Series LED Features •Low copper content aluminum minimizes corrosion • Philips LED System •Replaces up to 400 watt Metal Halide •Color Temperature: 4,100 CCT (K) standard. 3,500K and 5,000K •CRI: > 82 •60,000 or more hours rated life expectancy with minimum 70% lumen maintenance •Total Lumens: 148 Watts clear: 14,112 prismatic: 13,090 •Constant Current •120-277V, 50/60Hz or 347/480V, 60Hz •Line Transient Protection: 4 KV line to line, 2 KV line to ground •Standard fixture suitable for freezer applications •Fixture suitable for -20°F (-28°C) to +50°C (+122°F) ambient temperature 26 Certifications •NEMA Type 4X •CUL Listed •NSF Certified Food Equipment •Enclosed and Gasketed •Tested to LM79 & LM80 standards •Hose Down Tested Standard Materials •Continuously welded aluminum construction •FDA accepted powder coated finish •Stainless steel hardware •Extruded silicone lens frame gasket •Hinged reflector assembly WFHN Series LED Catalog Number Logic WFH N 150- 24 -4S-CA-U- DH-XX 1 1 2 3 4 2 BASIC SERIES WFHN LED Hose Down High Bay UL 1598 Wet Locations UL 8750 LED Safety CUL NEMA 4X Wash Down Rated Hose Down Tested to 1200psi Fire Hose Tested at 65gpm NSF Certified Food Equipment LED MAXIMUM SYSTEM WATTAGE 150 = 148 Watt LED NOMINAL LUMINAIRE SIZE 24= 2 x 4 Foot NUMBER OF LIGHT STRIPS 4S=4 LED Strips 3 5 4 6 7 5 LENS TYPE CA = Clear Acrylic PA =Prismatic Acrylic 6 VOLTAGE/FREQUENCY U = 120-277V 50/60 HZ N = 347-480V 60 HZ 7 8 MOUNTING DH=Dual Hub 1/2 in. NPT SH=Single Hub 3/4 in. NPT OPTIONS1 F = Single Fuse- For USL Luminaires Only (For Luminaires Rated 277 VAC or Less) D = Dimmable (0-10 Volt) DF = Double Fuse- For USL Luminaires Only (For Luminaires Rated 277 VAC or Less) HNG = Hinged Lens Frame 35 = 3500K (CCT) 50 = 5000K (CCT) 1 Consult Factory for Pricing Catalog logic is for explaining number structure only. Not all combinations are possible. Consult Factory 27 FPF Series LED Features •Unique design tolerates high teperatures, temperature swings and high pressure hose down •No flat surfaces to collect contaminants •Enclosed housing eliminates the need for shatterproof lamps •50,000 or more hours rated lamp life with 70% lumen maintenance •Constant Current •120-277V, 50/60Hz or 347/480V, 60Hz •Up to 180 LEDs •Line Transient Protection: 4 KV line to line, 2 KV line to ground •Standard fixture suitable for freezer applications •Fixture suitable for -40°C (-40°F) to +45°C (+104°F) ambient temperature •Line Transient Protection: 4 KV line to line. 2 KV line to ground •Constant Current 28 Certifications •UL 1598 Wet Locations •UL 8750 LED Safety •NSF Certified Food Equipment •Enclosed and Gasketed •Tested to LM79 & LM80 standards •Hose down tested Standard Materials •Impact resistant DR acrylic housing •Glare free shield •Polycarbonate endcaps standard- stainless steel available •Stainless steel fixed mount kit standardstainless steel chain and band mount kits available •Stainless steel external hardware •3 foot lead with cord grip standard- water tight disconnects available FPF Series LED Catalog Number Logic FPF 05L-4-U-XX 1 1 2 3 4 BASIC SERIES1 FPF Non Metallic LED Fixture UL 1598 Wet Locations UL 8750 LED Safety NSF Certified Food Equipment 2 5 3 4 5 OPTIONS2 F = Single Fuse SS = Stainless Steel End Caps Fixtures are furnished with non-metallic cord grip and 3 ft. long #16 AWG 3 conductor type SOA cable. 2 Consult factory for pricing. 1 LED MAXIMUM SYSTEM WATTAGE 03L=25 Watt (2 foot) 05L=50 Watt (4 foot) 10L= 100 Watt (8 foot) NOMINAL FIXTURE LENGTH 2 = 2 Foot 4 = 4 Foot 8 = 8 Foot VOLTAGE/FREQUENCY U = 120-277V 50/60 HZ 29 CEX Series LED Features •Non-metallic •Red or Green legend •Single or dual panel design •LED light source- 25 year life expectancy •Maximim 4 watts power consumption •Fully integrated electronic circut board and components •Integrated battery backup option with three hour operation •Emergency fixtures meet or exceed NFPA 70 and NFPA 101 standards •Energy Star rated •Enclosed & gasketed •Operating temperature 0° C- 40° C 30 Certifications •Heavy Hose-Down •UL 924 Emergency Lighting •UL 8750 LED Safety Standard Materials •Acrylic outer water sheild •Stainless steel hardware •Polycarbonate end caps CEX Series LED Catalog Number Logic CEX-L-2-R-W-A-XX 1 2 3 4 6 5 7 1 BASIC SERIES CEX = Composite Exit Sign 5 HOUSING COLOR W = White 2 LAMP SOURCE L = LED–Light Emitting Diode 6 3 NUMBER OF FACES 1 = Single Face 2 = Double Face 7 VOLTAGE A = 120V 60HZ C = 277V 60HZ 4 LETTER COLOR R = Red G = Green OPTIONS1 EM = Emergency Battery Backup VR = Vandal Resistant Hardware 1Consult factory for pricing. 31 Western Commercial Lighting Unit #122, 9704 - 39 Avenue Edmonton, Alberta T6E6M7 Phone: +17804401197 www.WesternCL.com