Rig-A-Lite LED Luminaire Guide

advertisement
Rig-A-Lite
LED Luminaire Guide
Superior LED Technology for
Hazardous and Severe Environments
Five-Year Warranty
Rig-A-Lite LED Luminaires
The Rig-A-Lite LED luminaires are the perfect combination of
dependability, safety and energy efficiency for
facilities including hazardous and severe environments.
Since 1938, we have been at the forefront of lighting technology, providing industry
with intelligent solutions to their lighting dilemmas.
As LED technology has continued to improve, Rig-A-Lite has integrated it into our
vision of the future of lighting these specialty environments including petrochemical
refining, petroleum refining, waste water treatment facilities, pharmaceutical facilites,
food processing facilities, power plants and other industrial & manufacturing areas
where flammable vapors, gasses, ignitable dusts, fibers or flyings are present. Our
LED product series are also rated for marine environments, wet locations and heavy
hose-down applications- indoors or outdoors.
Compared to HID (high intensity discharge) technologies, LED (light emitting diode)
technology provides extended life expectancy, greater energy effeciency and reduced
maintenace costs with a comparable or better quality of light.
Highly efficient LED drivers provide current regulation for consistent performance in severe
environments. LED arrays also provide consistent, energy efficient and long life output.
Our die cast aluminum and acrylic housings allow for efficient heat sink and UL listed/
NEMA rated protection in a traditional style that the industry is familiar with.
All of our LED luminaires are fully retrofittable in the field, allowing our customers to
grow with the technology while minimizing the cost of doing so.
Photometric performance of LED luminaires is evolving quickly. We have made every
effort to accurately describe the actual performance of our luminaires and will
incorporate new technologies to assure maximum performance and energy savings as
they are available.
We will continue our commitment to quality by
providing a five year warranty against
manufacturing defects on
all LED luminaires.
2
XPEX Series LED
Features
•Explosion Proof LED Exit Light
•Red or green legend
•Single or dual panel edge lit design
•LED light source- 25 year life expectancy
•Maximum 3 watts power consumption
•Fully integrated electronic circut board and
components
•Integrated battery backup option with three
hour operation
•Emergency fixtures meet or exceed NFPA 70
and NFPA 101 standards
•Energy Star rated
•Factory sealed
•Custom colors available
•Custom legends available
Certifications
•Class I, Division 1, Groups C & D
•Class II, Division 1 & 2, Groups E, F & G
•Class III
•Class I, Zone 1, Groups IIA, IIB
•Zone 2, Groups IIA & IIB + H2 & IIC
•UL 1598A Marine Outside Type
•UL 844, 8750 & 924
•IP65
•Temperature Class (T-Rating)- T6
•Patent Number 7,287,347
Standard Materials
•Copper Free Cast Aluminum Alloy Housing
•Epoxy Powder Coated
•Wall/Pendant or End Mount Configurations
•Acrylic Lens
Certification Guide
Model
Legend
XPEX
XPEX
Green
Red
Ambient
Class II, Div. 1,
Temperature Class I, Div. 1, Groups E, F, G,
°C
Groups C, D
Class III
40
T6
T6
55
T6
T6
Simultaneous
Presence
Class I & Class II
T6
T6
Class I, Zone 1,
Groups IIA, IIB
T6
T6
UL1598A
Outdoor
YES
YES
3
XPEX Series LED
Catalog Number Logic
XPEX-2-G-DT-WP-XX
1
1
2
2
BASIC SERIES
XPEX Explosion Proof LED Exit Light
Class I, Division 1, Groups C, & D
Class II, Division 1 Groups E, F & G
Class III
Class I , Zone 1, Groups IIA, IIB,
Zone 2, Groups IIA, IIB + H2 & IIC
Marine Outside Type
UL 1598A, 8750, 844, 924
IP65
Temperature Class (T-Rating)-T6
NUMBER OF FACES
1 = Single Face
2 = Double Face
3
4
5
3
4
6
LEGEND COLOR
R = Red
G = Green
VOLTAGE/FREQUENCY
DT = 120/277V 60HZ
24 = 220-240V 50/60HZ
Other voltages available- consult factory
5
MOUNTING
WP = Wall/Pendant Mounting
EB =End Bracket
6
OPTIONS1
EM=Emergency Battery Backup
EU=Green Running Man Exit Legend
SD= Self Diagnostics
X = Exit Legend in Other Languages
Language Must Be Specified
1Consult factory for pricing.
Operating Temperature Range
Temperature Rating- T6
Red Legend
Green Legend
+10° C Minimum to +55° C Maximum
+10° C Minimum to +40° C Maximum
Battery Wattage
Red without battery- 1.5 Watts
Red with battery- 2.5 Watts
Green without battery- 2.3 Watts
Green with battery- 3 Watts
4
XPS Series LED
Features
•Explosion Proof LED Multipurpose Sign
Light
•Red or green legend
•Single or dual panel edge lit design
•LED light source- 25 year life expectancy
•Maximum 3 watts power consumption
•Fully integrated electronic circut board and
components
•Integrated battery backup option with three
hour operation
•Emergency fixtures meet or exceed NFPA 70
and NFPA 101 standards
•Energy Star rated
•Factory sealed
•Custom colors available
•Custom legends available
Certifications
•Class I, Division 2, Groups A, B, C & D
•Class II, Division 2, Groups F & G
•Class III
•UL 1598A Marine Outside Type
•UL 844, 8750 & 924
•ETL Listed
•IP65
•Temperature Class (T-Rating)- T6
•Patent Number 7,287,347
Standard Materials
•Copper Free Cast Aluminum Alloy Housing
•Epoxy Powder Coated
•Wall/Pendant or End Mount Configurations
•Acrylic Lens
Certification Guide
Model
Legend
XPS
XPS
Green
Red
Ambient
Temperature
°C
40
40
Class I, Div. 1,
Groups C, D
T6
T6
Class II, Div. 1,
Groups E, F, G,
Class III
T6
T6
Simultaneous
Presence
Class I, Zone 1, UL1598A
Class I & Class II Groups IIA, IIB Outdoor
T6
T6
YES
T6
T6
YES
5
XPS Series LED
Catalog Number Logic
XPS-2-G-DT-WP-XX
1
1
2
2 3
BASIC SERIES
XPS Explosion Proof LED Exit Light *
*Customer must specify sign color and legend
Class I, Division 1, Groups C, & D
Class II, Division 1 Groups E, F & G
Class III
Class I , Zone 1, Groups IIA, IIB,
Zone 2, Groups IIA, IIB + H2 & IIC
Marine Outside Type
UL 1598A, 8750, 844, 924
IP65
Temperature Class (T-Rating)-T6
NUMBER OF FACES
1 = Single Face
2 = Double Face
4
5
6
3
LEGEND COLOR
A = Amber B = Blue
R = Red
G = Green
X = Other (Consult Factory)
4
VOLTAGE/FREQUENCY
DT = 120/277V 60HZ
24 = 220-240V 50/60HZ
Other voltages available- consult factory
5
MOUNTING
WP = Wall/Pendant Mounting
EB =End Bracket
6
OPTIONS1
EM=Emergency Battery Backup
X = Specify Legend (Cannot Say EXIT)
Language Must Be Specified
1Consult factory for pricing.
Operating Temperature Range
Temperature Rating- T6
Red Legend
Green Legend
+10° C Minimum to +55° C Maximum
+10° C Minimum to +40° C Maximum
Battery Wattage
Red without battery- 1.5 Watts
Red with battery- 2.5 Watts
Green without battery- 2.3 Watts
Green with battery- 3 Watts
6
SXPJ Series LED
Features
•Glare Free Performance
•Replaces up to 250 watt Metal Halide and 250
watt High Pressure Sodium
•60,000 or more hours rated lamp life with 70%
lumen maintenance
•Constant Current
•120-277V 50/60Hz
•55º C Maximum Ambient Temperature
•Line Transient Protection: 4 KV line to line 2
KV line to ground
Certifications
•Class I, Division 1, Groups C & D
•Class II, Division 1, Groups E, F & G
•Class I, Zone I, Groups IIA & IIB
•Class III
•Factory Sealed
•NEMA 3, 4, 4X & 7CD
•UL 1598, 1598A, 8750, & 844
•Tested to LM79 & LM80 standards
Standard Materials
Mounting Options
•Copper Free Cast Aluminum Alloy Housing
•Baked Epoxy Powder Coating
•Stainless Steel External Hardware
•Prismatic Tempered Glass Globe
•Stainless Steel Guard
•Silicone Gaskets
•Stanchion
•Wall
•Ceiling
•Pendant
•Trunnion
Certification Guide
Lamp
Rated
Ambient
°C
Catalog #
SXPJ10L
SXPJ10L
Type
Watts
LED
LED
98
98
Class I, Groups C & D,
Class 1, Zone 1,
Groups IIA, IIB, & IIC
Mounts
Pendant, Wall
or Ceiling
40
55
85 (T6)
85 (T6)
Class II, Groups
E, F & G
Class III
Mounts
Trunnion
or
Stanchion
85 (T6)
85 (T6)
Pendant, Wall, Ceiling
or Stanchion only
85 (T6)
---
Supply Wire
Temperature
Rating,
Minimum °C
90
90
7
Catalog Number Logic
SXPJ 10-L-U-GG-P-XX
1
1
BASIC SERIES
Class I, Division 1, Groups C & D
Class II, Division 1, Groups E, F & G*
Class III
Class I, Zone 1, Groups IIA & IIB
Factory Sealed
UL 1598, 1598A, 8750 & 844
NEMA Type 4X, IP66
Tested to IESNA LM79 & LM80 standards
2
3 4
5
5
6
* Except Trunnion Mount
2
LAMP TYPE
10=98 Watt (LED Only)
3
LAMP CURRENT/LAMP WATTAGE
L=LED
4
BALLAST VOLTAGE
U=120-277V 50/60HZ
7
6
7
GLOBE & GUARD
GG = Globe and Guard
G = Globe only
MOUNTING STYLE
P = 3/4" Pendant Mount
P1 = 1" Pendant Mount
C = 3/4" Ceiling Mount
C1 = 1" Ceiling Mount
W = 3/4" Wall Mount
W1 = 1" Wall Mount
S = 1-1/4" Stanchion Mount
S1 = 1-1/2" Stanchion Mount
T = Trunnion Mount
OPTIONS¹
FB = Fuse Block ² ³
1Consult factory for pricing.
Please specify voltage. When installed, one fuse block is
provided for 120 & 277v and two fuse blocks are provided for
208 & 240v.
3Fuse option not available for marine listed fixtures.
2
Catalog logic is for explaining number structure only. Not all combinations are possible. Consult Factory
8
XP Series LED
Features
Certifications
•2, 3 or 4 Lamp Versions
•Emergency Battery Backup
(2 ft. emergency operation only)
•0-10 Volt Dimming Available
•Outboard Option Available
•60,000 or more hours rated lamp life with 70%
lumen maintenance
•Factory Sealed
•Constant Current
•120-277V 50/60Hz
•-20º C-55º C Ambient Temperature
•Line Transient Protection: 4 KV line to line 6
KV line to ground
•Class I, Division 1, Groups C & D
•Class II, Division 1, Groups E, F & G
•Class III
•Factory Sealed
•NEMA 3, 4, 4X, 7CD & 9EFG
•UL 1598, 1598A, 8750, & 844
•Class I, Zone 1, Groups IIA and IIB
•Class I, Zone 2, Groups IIA, IIB & IIC
•Paint Spray Booth
•CUL Pending
•IP66
•Tested to LM79 & LM80 standards
•Patent Pending
Standard Materials
•Copper Free Aluminum Alloy Housing
•Aluminum Driver Housing
•Extruded Aluminum Reflectors
•Explosion Proof, Heat Resistant and Impact
Resistant Pyrex Tubes
Certification Guide
Model
Ambient
Temperature
(°C)
Class I, Div. 1,
Groups C, D
Class II, Div. 1,
Groups E, F, G,
Class III
XP30L22LU
XP40L23LU
XP50L42LU
XP75L43LU
XP100L44LU
55
55
55
55
55
T6
T6
T6
T6
T6
T4A
T5
T4A
T5
T4A
Simultaneou
s Presence UL1598A
Outdoor
Class I &
Class II
T4A
YES
T5
YES
T4A
YES
T5
YES
T4A
YES
PAINT
SPRAY
BOOTH
YES
YES
YES
YES
YES
9
LED
XP Series
Explosion Proof • Paint Spray Booth • UL 844 • UL 1598A Marine Outside Type • Factory Sealed
XP Series LED
Catalog Number Logic
XP 75L- 4 -3L-U -XX
1
1
2
2
BASIC SERIES
XP LED FIXTURE
Class I, Division 1, Groups C & D
Class II, Division 1, Groups E, F & G
Class III
Simultaneous Presence
NEMA 3, 4X, 7CD, 9EFG
UL 1598, UL 1598A, UL 844 & UL 8750
CUL Pending
IP66
55°C Ambient Temperature
Class I, Zone 1, Groups IIA & IIB
Class I, Zone 2, Groups IIA, IIB & IIC
Suitable for Inside Paint Spray Booth
Patent Pending
Tested to LM 79 & LM 80
3
5
4
3
6
NOMINAL FIXTURE LENGTH
2 = 2 Foot
4 = 4 Foot
4
NUMBER OF LAMPS
2L = 2 Tubes
3L = 3 Tubes
4L = 4 Tubes
5
VOLTAGE/FREQUENCY
U = 120 thru 277V 50/60 HZ
6
OPTIONS1
EM = Emergency Battery Backup Pending
D = Dimmable (0-10 Volt)
F = Inline Fuse (External)2
OB = Out Board Option
35 = 3500K (CCT)
50 = 5000K (CCT)
LAMP CURRENT/LAMP WATTAGE
30L = 30 Watt LED (2 ft. 2 tube)
40L = 40 Watt LED (2 ft. 3 tube)
50L = 46 Watt LED (4 ft. 2 tube)
75L = 73 Watt LED (4 ft. 3 tube)
100L = 93 Watt LED (4 ft. 4 tube)
1
2
Consult factory for pricing.
Fuse option not available for marine listed fixtures.
Catalog logic is for explaining catalog number structure only. Not all combinations are possible; consult factory for catalog numbers not listed in charts.
www.rigalite.com
10
11
HLEX Series LED
Features
•Hazardous Location LED Exit Sign
•Red or green legend
•Single or dual panel edge lit design
•LED light source- 25 year life expectancy
•Maximum 3 watts power consumption
•Fully integrated electronic circut board and
components
•Integrated battery backup option with three
hour operation
•Emergency fixtures meet or exceed NFPA 70
and NFPA 101 standards
•Energy Star rated
•Factory sealed
•Custom colors available
•Custom legends available
Certifications
•Class I, Division 2, Groups A, B, C & D
•Class II, Division 2, Groups F & G
•Class III
•UL 1598A Marine Outside Type
•UL 844, 8750 & 924
•ETL Listed
•IP65
•Temperature Class (T-Rating)- T6
•Patent Number 7,287,347
Standard Materials
•Copper Free Cast Aluminum Alloy Housing
•Epoxy Powder Coated
•Wall/Pendant or End Mount Configurations
•Acrylic Lens
Certification Guide
Model
HLEX
HLEX
Class II, Div. 1,
Class
I,
Div.
1,
Groups
E, F, G,
Ambient
Legend
Temperature °C Groups C, D
Class III
Green
40
T6
T6
Red
55
T6
T6
Simultaneous Presence
Class I & Class II
T6
T6
Class I, Zone 1, UL1598A
Groups IIA, IIB Outdoor
T6
YES
T6
YES
11
HLEX Series LED
Catalog Number Logic
HLEX-2-G-DT-WP-XX
1
1
2
2 3
BASIC SERIES
HLEX Hazardous Location Exit Light
Class I, Division 2, Groups A, B, C, & D
Class II, Division 2, Groups F & G
Class III
UL 1598A Marine Outside Type
UL 844, 8750, 924
IP65
ETL Listed
Temperature Class (T-Rating)-T6
NUMBER OF FACES
1 = Single Face
2 = Double Face
4
5
6
3
LEGEND COLOR
R = Red
G = Green
4
VOLTAGE/FREQUENCY
DT =120/277V 60HZ
24 = 220-240V 50/60HZ
Other voltages available- consult factory.
5
MOUNTING
WP = Wall/Pendant Mounting
EB =End Bracket
6
OPTIONS1
EM = Emergency Battery Backup
EU = Green Running Man Exit Legend
SD = Self Diagnostics
X = Exit Legend in Other Languages
Language Must Be Specified
1Consult factory for pricing.
Operating Temperature Range
Temperature Rating- T6
Red Legend
Green Legend
+10° C Minimum to +55° C Maximum
+10° C Minimum to +40° C Maximum
Battery Wattage
Red without battery- 1.5 Watts
Red with battery- 2.5 Watts
Green without battery- 2.3 Watts
Green with battery- 3 Watts
12
HLS Series LED
Features
•Hazardous Location LED Multipurpose Sign
Light
•Red or green legend
•Single or dual panel edge lit design
•LED light source- 25 year life expectancy
•Maximum 3 watts power consumption
•Fully integrated electronic circut board and
components
•Integrated battery backup option with three
hour operation
•Emergency fixtures meet or exceed NFPA 70
and NFPA 101 standards
•Energy Star rated
•Factory sealed
•Custom colors available
•Custom legends available
Certifications
•Class I, Division 2, Groups A, B, C & D
•Class II, Division 2, Groups F & G
•Class III
•UL 1598A Marine Outside Type
•UL 844, 8750 & 924
•ETL Listed
•IP65
•Temperature Class (T-Rating)- T6
•Patent Number 7,287,347
Standard Materials
•Copper Free Cast Aluminum Alloy Housing
•Epoxy Powder Coated
•Wall/Pendant or End Mount Configurations
•Acrylic Lens
Certification Guide
Model
Legend
HLS
HLS
Green
Red
Ambient Temperature Class I, Div. 1,
°C
Groups C, D
40
T6
55
T6
Class II, Div. 1,
Groups E, F, G,
Class III
T6
T6
Simultaneous
Presence
Class I & Class
T6
T6
Class I, Zone 1,
Groups IIA, IIB
T6
T6
UL1598A
Outdoor
YES
YES
13
HLS Series LED
Catalog Number Logic
HLS-2-G-DT-WP-XX
1
1
2
2 3
4
5
6
BASIC SERIES
HLS Hazardous Location LED Multipurpose Sign Light*
* Customer must specify sign color and legend
Class I, Division 2, Groups A, B, C, & D
Class II, Division 2, Groups F & G
Class III
UL 1598A Marine Outside Type
UL 844, 8750, 924
IP65
ETL Listed
Temperature Class (T-Rating)-T6
3
LEGEND COLOR
A = Amber
B = Blue
R = Red
G = Green
X = Other (Contact Factory)
4
VOLTAGE/FREQUENCY
DT = 120/277V 60HZ
24 = 220-240V 50/60HZ
Other voltages available- consult factory.
NUMBER OF FACES
1 = Single Face
2 = Double Face
5
6
MOUNTING
WP = Wall/Pendant Mounting
EB =End Bracket
OPTIONS1
EM=Emergency Battery Backup
X = Specify Legend (Cannot Say EXIT)
1Consult factory for pricing.
Operating Temperature Range
Temperature Rating- T6
Red Legend
Green Legend
+10° C Minimum to +55° C Maximum
+10° C Minimum to +40° C Maximum
Battery Wattage
Red without battery- 1.5 Watts
Red with battery- 2.5 Watts
Green without battery- 2.3 Watts
Green with battery- 3 Watts
14
SAFR Series 75 Watt LED
Features
Certifications
Mounting & Lens Options
Standard Materials
•Glare Free Performance with threaded and
frosted refractors
•Replaces up to 100 watt Metal Halide and 100
watt High Pressure Sodium
•60,000 or more hours rated lamp life with 70%
lumen maintenance
•Constant Current
•120-277V 50/60Hz
•347/480V 60Hz
•Junction Temperature: 97º C in a 55º C Ambient
•Line Transient Protection: 1 KV line to line. 1 KV
line to ground
Mounting Styles Include
•Stanchion (25° & 90°)
•Wall
•Ceiling
•Pendant
•Flexible Pendant
•Cone
Lens Options Include
•Type V Refractor
•Low Profile Clear Globe*
•Low Profile Frosted Globe*
•Class I, Division 2, Groups A, B, C & D
•Class II, Division 1, Groups E, F & G
•Class III
•Class I, Zone 2, Groups IIA, IIB & IIC
•Simultaneous Presence
•Enclosed and Gasketed
•NEMA 3R, 4X
•UL 8750,1598,1598A & 844
•CUL
•IP 66
•AEx nR II, T4
•Tested to LM79 & LM80 standards
•Copper Free Cast Aluminum Alloy Housing
•Epoxy Powder Coated
•Stainless Steel Hardware
•Tempered Glass Globe
•Stainless Steel Guard
•Silicone Gaskets
* Patent # D637339S
Certification Guide
Class I, Div.2
CLASS Il & lll
MODEL
AMBIENT
°C
Groups
A,B,C & D
GROUPS
SAFR09L
SAFR09L
40
55
T4A
T4A
E,F,G
E,F,G
Simultaneous
Presence
Class I, Zone 2
UL 1598A
OUTDOOR
T6
T6
T3C
T3C
YES
YES
AEx nR II
T4
T4
CUL
SUPPLY
WIRE
SUITABLE
TEMP °C
YES
YES
90
105
15
SAFR Series 98 Watt LED
Features
Certifications
Mounting & Lens Options
Standard Materials
•Glare Free Performance with threaded and
frosted refractors
•Replaces up to 175 watt Metal Halide and 150
watt High Pressure Sodium
•60,000 or more hours rated lamp life with 70%
lumen maintenance
•Constant Current
•120-277V 50/60Hz
•347/480V 60 Hz
•Line Transient Protection: 4 KV line to line. 2 KV
line to ground
•Class I, Division 2, Groups A, B, C & D
•Class II, Division 1, Groups E, F & G
•Class III
•Class I, Zone 2, Groups IIA, IIB & IIC
•Simultaneous Presence
•Enclosed and Gasketed
•NEMA 3R, 4X
•UL 8750,1598,1598A & 844
•CUL
•IP 66
•AEx nR II
•Tested to LM79 & LM80 standards
Mounting Styles Include
•Stanchion (25° and 90°)
•Wall
•Ceiling
•Pendant
•Flexible Pendant
•Cone
Lens Options Include
•Type V Refractor
•Low Profile Clear Globe*
•Low Profile Frosted Globe*
•Copper Free Cast Aluminum Alloy Housing
•Epoxy Powder Coated
•Stainless Steel Hardware
•Tempered Glass Globe
•Stainless Steel Guard
•Silicone Gaskets
* Patent # D637339
Certification Guide
Class I, Div.2
16
CLASS Il & lll
MODEL
AMBIENT
°C
Groups
A,B,C & D
GROUPS
SAFR11L
SAFR11L
40
55
T3A
T3A
E,F,G
E,F,G
Simultaneous
Presence
CID2
C2 D1
Class I, Zone 2
UL 1598A
OUTDOOR
T6
T6
T3A
T3A
YES
YES
AEx nR II
T3
T3
CUL
SUPPLY
WIRE
SUITABLE
TEMP °C
YES
YES
90
105
Catalog Number Logic
SAFR 09-L-U -T5G-P-XX
1
1
2
BASIC SERIES SAFR
Hazardous Location LED
Class I, Division 2, Groups A, B, C & D
Class II, Division 1 & 2, Groups E, F & G
Class III
Simultaneous Presence
Class I, Zone 2, Groups IIA, IIB & IIC
Enclosed and Gasketed
Wet Locations
NEMA 3R, 4X; IP66
UL 1598, 1598A, 844 & 8750
CUL
ABS Type Approved
Restricted Breathing
(Annual Testing Not Required)
AEx nR II
2
5
3 4
5
6
7
GLOBE & GUARD
LC = Low Profile Clear Globe Only
LCG = Low Profile Clear Globe & Guard
LF = Low Profile Frosted Globe Only
LFG = Low Profile Frosted Globe & Guard
T5 = Type V (Symmetric)
Closed Bottom Glass Refractor
T5G = Type V (Symmetric)
Closed Bottom Glass Refractor & Guard
6
MOUNTING STYLE
P = 3/4" Pendant Mount
P1 = 1" Pendant Mount
C = 3/4" Ceiling Mount
C1 = 1" Ceiling Mount
W = 3/4" Wall Mount
W1 = 1" Wall Mount
S = 1-1/4" 25° Stanchion Mount
S1 = 1-1/2" 25° Stanchion Mount
L = 1-1/4” 90° Stanchion Mount
L1 = 1-1/2” 90° Stanchion Mount
K = 3/4" Cone Top
K1 = 1" Cone Top
7
OPTIONS1
SS = Stainless Steel Inserts (304)
FB1 = Single Fuse Block 2,3
FB2 = Double Fuse Block 2,3
TB = Terminal Block
LAMP CURRENT/LAMP WATTAGE
09 = 75 Watt
11 = 98 Watt
1 Consult
3
4
factory for pricing
available unless incoming voltage is specified.
When installed, one fuse block is provided for 120,
277V and two fuse blocks are provided for 208,
240 and 480V. Fuse not included. Not available on
347V or 480V
3 Fuse option not available for marine listed fixtures.
2 Not
LAMP TYPE
L = LED
DRIVER VOLTAGE
U = 120-277V 50/60HZ
N = 347/480V 60HZ
17
SAFJ Series LED
Features
Certifications
•Glare Free Performance with frosted globe
•Replaces up to 70 watt Metal Halide and 70
watt High Pressure Sodium
•60,000 or more hours rated lamp life with 70%
lumen maintenance
•Constant Current
•120-277V 50/60Hz
•347/480V 60Hz
•Total Efficacy of 72.4 Lm/W with Clear Globe
•Line Transient Protection: 4 KV line to line 2
KV line to ground
•Class I, Division 2, Groups A, B, C & D
•Class II, Division 1 & 2, Groups E, F & G
•Class III
•Simultaneous Presence
•Enclosed and Gasketed
•NEMA 3R, 4X
•UL 1598A, 8750
•CUL
•IP 66
•Tested to LM79 & LM80 standards
Mounting & Lens Options
•Copper Free Cast Aluminum Alloy Housing
•Epoxy Powder Coated
•Stainless Steel Hardware
•Tempered Glass or Polycarbonate Clear or
Frosted Globe
•Stainless Steel Guard
•Silicone Gaskets
Mounting Styles Include
•Stanchion (25° and 90°)
•Wall
•Ceiling
•Pendant
•Flexible Pendant
Glass and Poly. Lens Options Include
•Low Profile Clear Globe*
•Low Profile Frosted Globe*
Standard Materials
* Patent # D637340S
Ambient
Watts Type Temperature
°C
Model
SAFJ06
SAFJ06
18
45
45
1
2
LED
LED
40
55
Supply
Class I, Div. 21 Class II, Div. 12 Simultaneous Wire Suitable UL1598A CUL
Groups A,B, C, D
Class III
Presence
Temp °C
Outdoor
T3C
T3C
T5 (E, F & G)
T3A (E & F)
T3
T3
105
105
Yes
Yes
Yes
Yes
With or without external reflectors (fixtures can be used with or without external reflectors in Class I, Div. 2 areas only).
Without external reflectors (use of external reflectors is not permitted for fixtures in Class II environments)
SAFJ Series LED
Catalog Number Logic
SAFJ 06-L-U- LFG-C- X
1
1
2
3
4
2
3
4
BASIC SERIES
SAFJ LED
Class I, Division 2, Groups A, B, C, & D
Class II, Division 1, Groups E, F & G
Class III
Simultaneous Presence
Enclosed & Gasketed
Wet Locations
UL1598A Marine Outside Type
UL 844 Hazardous Locations
UL 8750 LED Safety
NEMA 3R,4X
IP66
CUL
ABS Type Approved
5
6
LAMP CURRENT/LAMP WATTAGE
06 = 45 Watt
LAMP TYPE
L = LED
DRIVER VOLTAGE
U = 120-277V 50/60HZ
N = 347/480V 60HZ
7
5
6
7
GLOBE & GUARD
LC = Low Profile Clear GlassGlobe
LCG = Low Profile Clear Glass Globe & Guard
LPC = Low Profile Clear Polycarbonate
LPCG = Low Profile Clear Polycarbonate & Guard
LF = Low Profile Frosted Glass Globe
LFG = Low Profile Frosted Glass Globe & Guard
LPF = Low Profile Frosted Polycarbonate Globe
LPFG = Low Profile Frosted Polycarbonate Globe & Guard
MOUNTING STYLE
P = ¾" Pendant Mount
P1 = 1" Pendant Mount
C = ¾" Ceiling Mount
C1 = 1" Ceiling Mount
W = ¾" Wall Mount
W1 = 1" Wall Mount
S = 1-¼" 25°Stanchion Mount
S1 = 1-½" 25°Stanchion Mount
L = 1-¼" 90°Stanchion Mount
L1 = 1-½" 90°Stanchion Mount
OPTIONS1
SS = Stainless Steel Inserts
SC = Safety Cable
FB1 = Single Fuse Block
FB2 = Double Fuse Block
1Consult
factory for pricing.
available with universal dirver
unless incoming voltage is specified.
When installed, one fuse block is
provided for 120 & 277V
and two fuse blocks are provided for
208, 220, 240, 347 and 480V.
Fuse not provided.
3FB option not available for marine listed
fixtures.
2Not
Catalog logic is for explaining catalog number structure only. Not all combinations are possible; consult factory for catalog numbers not listed in charts.
19
MHDA/MHDS Series LED
Features
•Hazardous location marine rated LED
•Stainless steel mounting brackets
•Heavy duty injection molded lens with
reinforced corners
•Dual stainless steel lens tethers
•Ceiling mount or pendant mount options
•60,000 or more hours rated lamp life with 70%
lumen maintenance
•3/4” NPT Aluminum Conduit Hubs
•Water tight gasket attached to the lens for
superior ingress protection
•Line Transient Protection: 4 KV line to line. 2
KV line to ground
•Constant Current
Certifications
•Class I, Division 2, Groups A, B, C & D
•Class II, Division 2, Groups F & G
•Class III
•UL 1598A Marine Outside Type
•UL 844, 8750
•Tested to LM79 & LM80
•CSA C22.2 #137
•CSA C22.2 #213
•ETL Listed
•55° C Ambient Temperature
•IP66
Standard Materials
•Copper Free Cast Aluminum Alloy Housing
or 304 Stainless Steel- 316 Stainless Steel
Option Available
•Epoxy Powder Coated White
•Captive Stainless Steel Latches
•Acrylic Lens- Polycarbonate Option Available
Certification Guide
Model
MHDA/S10L4U
20
Ambient
Class II, Div. 2,
Class I, Div. 2 Groups
Temperature
Groups F & G,
A, B, C & D
°C
Class III
55
T4A
T4
Supply Wire
Suitable
Temperature °C
105
MHDA/MHDS Series LED
Catalog Number Logic
MHDA 10-L- 4 -U-XX
1
1
2
3
4
2
BASIC SERIES
MHDA Aluminum LED
MHDS Stainless Steel LED
Class I, Division 2, Groups A, B, C and D
Class II, Division 2 Groups F & G
Group III
UL 844 Hazardous Locations
UL 1598A Marine Outside Type
UL 8750 LED Safety
CSA C22.2 #137; C22.2 #213
ETL Listed
Tested to LM79 & LM80
55° C Ambient Temperature
IP66
LAMP CURRENT/LAMP WATTAGE
10 = 80 Watt
3
4
6
5
5
6
VOLTAGE/FREQUENCY
U = 120-277V 50/60 HZ
OPTIONS1
P = Polycarbonate Lens
FB = Fuse Block2
TB = Terminal Block
TW = Thru Wire
Cable Installations Only
PM = Pendant Mount
SP = Surge Protector
316 = 316 Stainless Steel Housing
1
Consult factory for pricing.
option not available for marine listed fixtures.
2 Fuse
LAMP TYPE
L = LED
NOMINAL FIXTURE LENGTH
4 = Four Foot
21
MAR2 Series LED
Features
•Hazardous Location Marine Rated LED
•Cast Aluminum End Caps
•UV Resistant Non-Metallic Hinges
•Extruded Aluminum Lens Frame
•360° Mounting Flexibility
•60,000 or more hours rated lamp life with 70%
lumen maintenance
•3/4” NPT Aluminum Conduit Hubs
•Water tight gasket attached to the lens for
superior ingress protection
•Line Transient Protection: 4 KV line to line. 2
KV line to ground
•Constant Current
Certifications
•Class I, Division 2, Groups A, B, C & D
•UL 1598A Marine Outside Type
•UL 844 Hazardous Locations
•UL 8750 LED Safety
•Tested to LM79 & LM80
•CSA C22.2 #137
•CSA C22.2 #213
•ETL Listed
•55° C Ambient Temperature
Standard Materials
•Copper Free Extruded Aluminum Housing
•Stainless Steel Cam Action Latches
•Shatter and Heat Resistant Acrylic Lens
Certification Guide
Supply
Ambient
Wire
Class I, Division 2 Groups
Temperature
Suitable
A, B, C & D
°C
Model
Temp °C
MAR210L4U
55
T4A
105
MAR210L2U
55
T4A
105
22
MAR2 Series LED
Catalog Number Logic
MAR2 10 - L - 4 - U - XX
1
1
2
3
2
BASIC SERIES
MAR2 LED Fixture
Class I, Division 2, Groups A, B, C & D
UL 844 Hazardous Locations
UL 1598A Marine Outside Type
UL 8750 LED
CSA C22.2 #137
CSA C22.2 #213
ETL Listed
55°C Ambient Temperature
LAMP CURRENT/LAMP WATTAGE
10 = 80 Watt
LAMP TYPE
L = LED
3
4
4
5
6
5
6
NOMINAL FIXTURE LENGTH
2 = Two Foot
4 = Four Foot
VOLTAGE/FREQUENCY
U = 120-277 50/60HZ
OPTIONS1
TW = End Mounting/Thru Wire
Cable Installations Only
F = Single Fuse2
TM = Tempered Glass
EB = Eye Bolt Only
SC = Safety Cable with Eye Bolt
SP = Surge Protector
1Consult
2Fuse
factory for pricing.
option not available for marine listed fixtures.
23
WFH Series LED
Features
•Low copper content aluminum minimizes
corrosion
• Philips LED System
•Replaces up to 400 watt Metal Halide
•Color Temperature: 4,100 CCT (K) standard.
3,500K and 5,000K
•CRI: > 82
•60,000 or more hours rated life expectancy
with minimum 70% lumen maintenance
•Total Lumens:
148 Watts clear: 14,112 prismatic: 13,090
•Constant Current
•120-277V, 50/60Hz or 347/480V, 60Hz
•Line Transient Protection: 4 KV line to line,
2 KV line to ground
•Standard fixture suitable for freezer applications
•Fixture suitable for -20°F (-28°C) to +50°C
(+122°F) ambient temperature
24
Certifications
•Class I, Division 2, Groups A,B,C,D
•Class II, Division 2, Groups F & G
•Class III
•UL 844 Hazardous Locations
•UL 8750 LED Safety
•NEMA Type 4X
•CUL Listed
•NSF Certified Food Equipment
•Enclosed and Gasketed
•Tested to LM79 & LM80 standards
•Hose Down Tested
Standard Materials
•Continuously welded aluminum construction
•FDA accepted powder coated finish
•Stainless steel hardware
•Extruded silicone lens frame gasket
•Hinged reflector assembly
WFH Series LED
Catalog Number Logic
WFH 150- 24 -4S-CA-U- DH-XX
1
1
2
3
4
2
BASIC SERIES
WFH LED Hazrdous Location High Bay
Class I, Division 2, Groups A,B,C & D
Class II, Division 2, Groups F & G
Class III
UL 844 Hazardous Locations
UL 1598 Wet Locations
UL 8750 LED Safety
CUL
NEMA 4X
Wash Down Rated
Hose Down Tested to 1200psi
Fire Hose Tested at 65gpm
NSF Certified Food Equipment
LED MAXIMUM SYSTEM WATTAGE
150 = 148 Watt LED
NOMINAL LUMINAIRE SIZE
24= 2 x 4 Foot
NUMBER OF LIGHT STRIPS
4S=4 LED Strips
3
4
5
6
7
5
LENS TYPE
CA = Clear Acrylic
PA =Prismatic Acrylic
6
VOLTAGE/FREQUENCY
U = 120-277V 50/60 HZ
N = 347-480V 60 HZ
7
MOUNTING
DH=Dual Hub 1/2 in. NPT
SH=Single Hub 3/4 in. NPT
8
OPTIONS1
F = Single Fuse- For USL Luminaires Only
(For Luminaires Rated 277 VAC or Less)
D = Dimmable (0-10 Volt)
DF = Double Fuse- For USL Luminaires Only
(For Luminaires Rated 277 VAC or Less)
HNG = Hinged Lens Frame
35 = 3500K (CCT)
50 = 5000K (CCT)
1
Consult Factory for Pricing
Catalog logic is for explaining number structure only. Not all combinations are possible. Consult Factory
25
WFHN Series LED
Features
•Low copper content aluminum minimizes
corrosion
• Philips LED System
•Replaces up to 400 watt Metal Halide
•Color Temperature: 4,100 CCT (K) standard.
3,500K and 5,000K
•CRI: > 82
•60,000 or more hours rated life expectancy
with minimum 70% lumen maintenance
•Total Lumens:
148 Watts clear: 14,112 prismatic: 13,090
•Constant Current
•120-277V, 50/60Hz or 347/480V, 60Hz
•Line Transient Protection: 4 KV line to line,
2 KV line to ground
•Standard fixture suitable for freezer applications
•Fixture suitable for -20°F (-28°C) to +50°C
(+122°F) ambient temperature
26
Certifications
•NEMA Type 4X
•CUL Listed
•NSF Certified Food Equipment
•Enclosed and Gasketed
•Tested to LM79 & LM80 standards
•Hose Down Tested
Standard Materials
•Continuously welded aluminum construction
•FDA accepted powder coated finish
•Stainless steel hardware
•Extruded silicone lens frame gasket
•Hinged reflector assembly
WFHN Series LED
Catalog Number Logic
WFH N 150- 24 -4S-CA-U- DH-XX
1
1
2
3
4
2
BASIC SERIES
WFHN LED Hose Down High Bay
UL 1598 Wet Locations
UL 8750 LED Safety
CUL
NEMA 4X
Wash Down Rated
Hose Down Tested to 1200psi
Fire Hose Tested at 65gpm
NSF Certified Food Equipment
LED MAXIMUM SYSTEM WATTAGE
150 = 148 Watt LED
NOMINAL LUMINAIRE SIZE
24= 2 x 4 Foot
NUMBER OF LIGHT STRIPS
4S=4 LED Strips
3
5
4
6
7
5
LENS TYPE
CA = Clear Acrylic
PA =Prismatic Acrylic
6
VOLTAGE/FREQUENCY
U = 120-277V 50/60 HZ
N = 347-480V 60 HZ
7
8
MOUNTING
DH=Dual Hub 1/2 in. NPT
SH=Single Hub 3/4 in. NPT
OPTIONS1
F = Single Fuse- For USL Luminaires Only
(For Luminaires Rated 277 VAC or Less)
D = Dimmable (0-10 Volt)
DF = Double Fuse- For USL Luminaires Only
(For Luminaires Rated 277 VAC or Less)
HNG = Hinged Lens Frame
35 = 3500K (CCT)
50 = 5000K (CCT)
1
Consult Factory for Pricing
Catalog logic is for explaining number structure only. Not all combinations are possible. Consult Factory
27
FPF Series LED
Features
•Unique design tolerates high teperatures,
temperature swings and high pressure hose
down
•No flat surfaces to collect contaminants
•Enclosed housing eliminates the need for
shatterproof lamps
•50,000 or more hours rated lamp life with 70%
lumen maintenance
•Constant Current
•120-277V, 50/60Hz or 347/480V, 60Hz
•Up to 180 LEDs
•Line Transient Protection: 4 KV line to line,
2 KV line to ground
•Standard fixture suitable for freezer applications
•Fixture suitable for -40°C (-40°F) to +45°C
(+104°F) ambient temperature
•Line Transient Protection: 4 KV line to line. 2
KV line to ground
•Constant Current
28
Certifications
•UL 1598 Wet Locations
•UL 8750 LED Safety
•NSF Certified Food Equipment
•Enclosed and Gasketed
•Tested to LM79 & LM80 standards
•Hose down tested
Standard Materials
•Impact resistant DR acrylic housing
•Glare free shield
•Polycarbonate endcaps standard- stainless
steel available
•Stainless steel fixed mount kit standardstainless steel chain and band mount kits
available
•Stainless steel external hardware
•3 foot lead with cord grip standard- water tight
disconnects available
FPF Series LED
Catalog Number Logic
FPF 05L-4-U-XX
1
1
2
3
4
BASIC SERIES1
FPF Non Metallic LED Fixture
UL 1598 Wet Locations
UL 8750 LED Safety
NSF Certified Food Equipment
2
5
3 4
5
OPTIONS2
F = Single Fuse
SS = Stainless Steel End Caps
Fixtures are furnished with non-metallic cord grip and 3 ft. long #16
AWG 3 conductor type SOA cable.
2
Consult factory for pricing.
1
LED MAXIMUM SYSTEM WATTAGE
03L=25 Watt (2 foot)
05L=50 Watt (4 foot)
10L= 100 Watt (8 foot)
NOMINAL FIXTURE LENGTH
2 = 2 Foot
4 = 4 Foot
8 = 8 Foot
VOLTAGE/FREQUENCY
U = 120-277V 50/60 HZ
29
CEX Series LED
Features
•Non-metallic
•Red or Green legend
•Single or dual panel design
•LED light source- 25 year life expectancy
•Maximim 4 watts power consumption
•Fully integrated electronic circut board and
components
•Integrated battery backup option with three
hour operation
•Emergency fixtures meet or exceed NFPA 70
and NFPA 101 standards
•Energy Star rated
•Enclosed & gasketed
•Operating temperature 0° C- 40° C
30
Certifications
•Heavy Hose-Down
•UL 924 Emergency Lighting
•UL 8750 LED Safety
Standard Materials
•Acrylic outer water sheild
•Stainless steel hardware
•Polycarbonate end caps
CEX Series LED
Catalog Number Logic
CEX-L-2-R-W-A-XX
1
2 3 4
6
5
7
1
BASIC SERIES
CEX = Composite Exit Sign
5
HOUSING COLOR
W = White
2
LAMP SOURCE
L = LED–Light Emitting Diode
6
3
NUMBER OF FACES
1 = Single Face
2 = Double Face
7
VOLTAGE
A = 120V 60HZ
C = 277V 60HZ
4
LETTER COLOR
R = Red
G = Green
OPTIONS1
EM = Emergency Battery Backup
VR = Vandal Resistant Hardware
1Consult
factory for pricing.
31
Western Commercial Lighting
Unit #122, 9704 - 39 Avenue
Edmonton, Alberta T6E6M7
Phone: +17804401197
www.WesternCL.com
Download