Back Light 2015 FD Series Inverter Packaged Air Conditioners Proudly supporting 2 FD Series Inverter Packaged Air Conditioners change setting by button taps only Run / Stop High power operation Energy-saving operation Maximum capacity operation (Max 15 minutes) • Increased compressor speed • Increased air flow • Changes set temperature at 28ºC in cooling mode and 22ºC in heating mode, 25ºC in auto mode. • Operation correction by outdoor temperature Main functions Energy management Peak cut timer • Automatic temperature set back • Weekly timer • Set ON/OFF timer by hour • Set ON/OFF timer by clock • Fan only operation • Sleep timer Comfort Individual flap control • High power operation • External ventilation ON/OFF • Warm up operation • Automatic fan speed • Temperature increment setting by 0.5ºC Convenience LCD contrast setting • Back light setting • Filter clean sign • Control sound • Outdoor silent mode • Summer time setting • Home leave mode • Indoor & outdoor temperature display • Heating standby display • Defrosting operation display • Auto cooling/heating display • ºC/ºF display • Administrator settings • Room name setting Service Error code display • Operation data display • Next service data display • Contact company display • USB connection (mini-B) Operation mode Cooling Dry FD series Inverter Packaged Air Conditioners 2015 Auto Fan Heating Advanced touch screen panel with full dot Liquid Crystal Display PRODUCTS Basic operation All settings are changed by tapping the touch screen panel Operation mode setting screen Temperature setting screen The operation mode can be selected by simply tapping this button. You can select the desired temperature by tapping the ▲▼ button. NEW IntesisHome Your our home in the cloud Intesis Wifi Adaptors RAC Model: IS-IR-WIFI-1 PAC Model: MH-RC-WIFI-1 3 FD Series 4 Hyperinverter Our advanced technology has allowed us to achieve high efficiency, powerful heating and long distance refrigerant piping specifications. This feature permits installation of the units when a heating in operation under temperature conditions down to -20˚C is required. Design flexibility has been improved by an extension of the refrigerant piping length to 100m (12.5 & 14.0kW). Micro SRC50ZMXA-S SRC60ZMXA-S FDCA71VNX FDC90VNP FDCA125VNX FDCA140VSX FDCA100VN FDCA160VSA FDCA200VSA Blue Fin 7.1-20.0kW Base heater kit (option) Due to application of blue coated fins (KS101) for the heat exchanger of the new outdoor unit, corrosion resistance has been improved compared to previous models. This kit is recommended for use in areas where the temperature drops below 0˚C. Blue Fin Blue Fin CW-H-E applied for FDCA100VN FDCA125~140VNX Micro Inverter Installation workability ø133mm diameter of shell& 14.0kW Long pipingOutside12.5 ø185mm Former compressor Height at 342mm Height at 440 mm Enhanced installation workability Compact design of outdoor thanks to the extended pipe units length – one of the longest levels * Vector control: FDCA100VN To convert the current in the industry. Units are prewave to a smooth Reduction in height by 22.3% sinusoidal waveform. 10.0kW condenser Our single fan micro charged with refrigerant. Reduction in volume by 44.1% is one of the most compact in the industry only 845(h)x970(w)x370(d) New model DC rotary compressor Height difference Height difference (Outdoor higher (Outdoor than Indoor) higher than Indoor) Piping length Piping length Refrigerant precharged piping MicroMicro Inverter Inverter length extending to Height difference Height difference30m (Outdoor higher (Outdoor than Indoor) higher than Indoor) Piping length Piping Height Piping length length kW difference Height difference 5~6 30m5~6 20m30m 20m 7.1 50m 7.1 30m50m 30m 12.5~14 100m 100m 12.5~1430m 30m kW FD series Inverter Packaged Air Conditioners 2015 Piping length Precharged refrigerant piping length extends up to 30m. (5.0 & 6.0kW up to 15m) This eliminates the need to Former model model Piping Height Piping Height add refrigerantCurrent on site, which length length difference kW kW difference 20msets it free from the trouble of 30m 9 20m30m 9 excessive or insufficient charging 30m 50m 10 30m50m 10 of refrigerant, and allows smooth 30m 70m* 70m* 16,20 16,20 30m installation. * Refer technical * Refer manual technical manual Size reduction and high efficiency performance of the DC twin rotary compressor * Vector control: To convert the current wave to a smooth sinusoidal waveform. Protection Improved operation of the electronic expansion valve allows for more reliable oil return and this assists to protect the compressor. Height at 342mm Height at 440 mm Reduction in height by 22.3% Reduction in volume by 44.1% Re-designing the fins to a straight shape has reduced the pressure loss of the air flow in the heat exchanger. A new surface treatment on the fins has enhanced the frost resistance capacity. A high speed fan motor has increased the airflow which allows cooling capacity to be maintained even at high outdoor air temperatures. FEATURES The DC twin rotary compressor can operate at speeds as high as 120 rps. Vector control provides perfect compressor control. Starting current has reduced significantly and vibration has been minimized. Improved efficiency of the heat exchanger Outside diameter of shell ø185mm ø133mm Former compressor New model DC rotary compressor Former model Current model High efficiency Reduction of air flow pressure loss common XR5 of the Heat transfer efficiency has improved by using high efficiency piping and by the redesign XR5 from 2 to 1 piece. XR1~5 : approx. DC12v Convenience XR1 XR2 XR4 XR3 XR4 A dry contact is fitted to each indoor unit which is used when a signal output is required. XR2 CnT CnT XR1 CnT terminal output3 (comp on) output4 (alarm) in put heat exchanger XR1 XR3 XR2 XR3 XR5 XR4 XR1~5 : approx. DC12v XR5 commoncommon XR1 output1 (run) output1 XR2 (run) output2 (heat) XR3 (heat) output3 (comp on) output2 XR4 output4 (alarm) output3 (comp on) in put XR5 output4 (alarm) in put source XR3 XR4 Power source Power XR3 XR4 Power source Increase of heat transfer efficiency CnT Pressure caused by air flow in the indoor unit is reduced by making the air outlet larger. The reduction of pressure XR1 output1 (run) XR1 reduces the load on the fan motor so increasing efficiency. XR2 output2 (heat) XR2 XR5 XR1~5 : approx. DC12v Monitoring Function Condensers are fitted with RS232C so you can connect directly to your PC for monitoring. MHI’s service software (Mente PC) makes service simpler. PAC converter necessary required to connect to PC directly Remote control RC-E5 The new remote control for all indoor units. Non-polar 2 core wiring is used. Installation is easier. Previous 3-core Current 2-core Previous 3-core Current 2-core All models employ R410A with RoHS* directive Previous Employment of lead free solder 3-core Current 2-core Adapt to RoHS Pressure caused by air flow in the indoor unit is reduced by making the air outlet larger. The reduction of pressure reduces the load on the fan motor so efficiency increases. *”RoHS” is the abbreviation of the European standard, which means Restriction of Hazardous Substances. Employment of R410A refrigerant All models of the FD inverter series use refrigerant R410A characterized by an ozone depletion coefficient of 0. 5 6 FDT-FDTC Ceiling Cassette - 4way - Indoor units Individual flap control system Individual flap control is possible even after installation. This means that the installation area has become wider than before. The outlet design has been perfected to allow flow that can reach a long distance from the indoor unit. Previous Previous Upper position Flap control system The design of the heat exchanger has changed from 2 parts to a single piece. The height of the indoor unit has been reduced significantly. *RCH-E3 is not applicable to the Individual flap control system and the Flap control system. Previous Upper position Current Current Movable range Movable Lower range position Upper position Lower position For person who is far Movable range For person whoindoor is far unit from the from the indoor unit Lower position The thinnest design DC fan motors are used to increase efficiency. Weight has been reduced and as a result the unit has become one of the most compact in the industry. Current FDT125~140 FDT125~140 18% 18% reduction!! For person who is far from the indoor unit reduction!! 365mm 365mm FDT125~140 18% reduction!! 298298 mm mm For both persons who are For both persons who are feeling or cold feeling hot orhot cold 365mm FDT71 FDT71 Shape of heat heatexchanger exchanger Shape of For both persons who are 9%9% 298 reduction!! reduction!! feeling hot or cold mm 270mm 270mm Previous Previous Current Current FDT71 246 9% 246 mmmm reduction!! Shape of heat exchanger Can Can cool cool both both the kitchen the kitchen and the andguests the guests 270mm Previous Current FD series Inverter Packaged Air Conditioners 2015 246 mm Can cool both the kitchen and the guests FDUA Indoor Unit Duct Connected - High Static Pressure PRODUCTS External static pressure (E.S.P.) control Selecting the external static pressure setting the optimum air flow volume can be achieved. The indoor unit will recognize the external static pressure setting and keep rated air volume. New FDUA Duct Duct Longer Duct Ceiling Keep the same air flow volume Setting No. 1 E.S.P. (Pa) 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 200 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 E.S.P. button External static pressure can be set by E.S.P. button. Improved servicing Improved servicing Fan unit (impeller and motor) can be pulled out from the right side of the unit. Maintenance access is available from both the right side and below the unit. Pipe Unit Fan unit Maintenance hole Service space 7 FDUA Indoor Unit Duct Connected - High Static Pressure MODELS: FDUA71VF, FDUA100VF, FDUA125VF, FDUA140VF Remote control (Options) Wired Wireless DRED enabled model RC-E5 RCH-E3 RCN-KIT3-E 200 Duct dimension Dimension H 398 (1) Indoor units Model FDUA71VF 65 Unit:mm 740 Duct dimension Symbol A Gas piping B Liquid piping C1 Drain piping Drain piping C2 Gravity drainage D Hole for wiring E Suspension bolts F Inspection hole 185 41 RC-EX1A 39 FDUA100/125/140/160VF Return air duct H 280 Drain hose piece Accessory Content 15.88 5 8" Flare 9.52 3 8" Flare VP25 I.D.25,O.D.32 VP20 I.D.20,O.D.26 M10 450X450 Installed on site FD series Inverter Packaged Air Conditioners 2015 55 880 Duct dimension 55 100 1300 C2 635 510 471 413 175 105 Max. drain lift 76 D 600 or less 295 325 15 Under 60 less than 600mm 30 280 250 472 Suspension bolts pitch 135 Air supply duct 43 Flexible hose E 620 Note 1 The model name label is attached on the lid of the control box. B A 58 67 Duct dimension Drain can be discharged upwards by 600mm from the ceiling surface. It allows a piping layout with a high degree of freedom depending on the installation location. C1 69 600 Inspection hole Control box 600mm Drain Pump From bottom of unit or more Case 2 18 284 82 28 FDUA71VF 18 or more Hanger plate for suspension bolt 986 Suspension bolts pitch 950 170 8 467 30 FDUA FDUA71AVNXVF Set FDUA100AVNVF FDUA100AVNXVF Indoor FDUA71VF FDUA100VF FDUA100VF FDUA125VF FDUA140VF FDCA71VNX FDCA100VN FDCA100VNX FDCA125VNX FDCA140VNX 7.1 (3.2-8.0) 10.0 (4.0-11.2) 10.0 (4.0-11.2) 12.5 (5.0-14.0) 14.0 (5.0-14.5) 8.0 (3.6-9.0) 11.2 (4.0-12.5) 11.2 (4.0-12.5) 14.0 (4.0-17.0) 16.0 (4.0-18.0) 2.22 3.05 2.85 3.83 4.44 Outdoor Unit 1 Phase 220-240V 50Hz Cooling T1 kW Heating H1 Cooling T1 Input kW Heating H1 2.22 2.87 2.74 3.68 4.41 3.20 3.28 3.51 3.26 3.15 EER Cooling T1 COP Heating H1 3.60 3.90 4.09 3.80 3.63 Indoor P-Hi:38 Hi:33 Me:29 Lo:25 P-Hi:43 Hi:42 Me:40 Lo:37 P-Hi:43 Hi:42 Me:40 Lo:37 P-Hi:45 Hi:43 Me:41 Lo:37 P-Hi:47 Hi:46 Me:43 Lo:40 51 49 48 48 Sound pressure level (JIS C9612) dB(A) Outdoor Sound power level (JIS C9612) Outdoor Airflow 66 Indoor External static pressure External dimensions (HXWXD) Indoor Net weight Refrigerant piping 398x1150x650 750x880(+88)x340 845x970x370 1300x970x370 34 52 60 81 105 Ø9.52 mm Gas line Ø15.88 Connection method Refrigerant R410A Flare Connection Quantity kg Pre charged to pipe length m Maximum pipe length 2.95 3.8 4.5 30 m 50 Supply air connection mm 170x880 Return air connection mm 200x740 100 348x898 RC-E5, RC-EX1A or RCN-KIT3-E Controller UA-SP1-E (Optional) UA-SP2-E (Optional) 348 898 Duct dimension 181 472 Inspection hole C1 69 B A 150 506 Case 2 17.5 284 86 VP25 I.D.25,O.D.32 VP25 I.D.25,O.D.32 M10 450X450 12.7 1 2" 22.22 7 8" From bottom of unit 40 295 325 G Under 60 or less 15 215 Air supply duct 111 898 Duct dimension 182 181 192 C2 650 Notes 1) The model name label is attached on the lid of the control box. (2) Connect the piping with local pipe by using the pipe of the attachment. Liquid side and Gas side 61 74 E Flare Brazing 100 1150 C2 111 Drain piping Drain piping Gravity drainage Hole for wiring Suspension bolts Inspection hole Connecting position of the local pipe. liquid side Connecting position of the local pipe. gas side Control box 24 Duct dimension 40 348 or less 215 650 531 498 458 398 370 248 172 15 Under 60 D 600 Air supply duct Max. drain lift 40 295 325 Suspension bolts pitch Hanger plate for suspension bolt 61 74 Flare 600 100 1500 650 B A E 17.5 600 Inspection hole C1 69 150 Suspension bolts pitch 472 Control box 9.52 3 8" D E F G H Drain hose piece Accessory 28 From bottom of unit or more Case 2 17.5 284 82 28 1150 Flare Connecting position of the attached connecting pipe liquid side or more Return air duct 1185 Suspension bolts pitch Suspension bolts pitch 15.88 5 8" B C2 Installed on site or more 1185 Connecting position of the attached connecting pipe gas side or more M10 450X450 A C1 VP25 I.D.25,O.D.32 Installed on site 17.5 181 1500 898 Duct dimension Max. drain lift Drain hose piece Accessory 15.88 5 8" Flare 9.52 3 8" Flare VP25 I.D.25,O.D.32 111 Content H D 650 531 498 458 40 398 370 248 172 24 Return air duct Content Symbol 26 Symbol A Gas piping B Liquid piping C1 Drain piping Drain piping C2 Gravity drainage D Hole for wiring E Suspension bolts F Inspection hole Duct dimension Unit:mm 181 Unit:mm Model FDUA160VF 24 898 Duct dimension 26 111 348 Duct dimension Models FDUA100VF, 125VF, 140VF 600 Safety pan 24 P-Hi:850 Hi:800 Me:700 Lo:600 200 kg Outdoor Liquid line Hanger plate for suspension bolt P-Hi:717 Hi:650 Me:600 Lo:500 280x950x635 mm Outdoor 72 P-Hi:650 Hi:600 Me:550 Lo:483 Pa Indoor 49 70 P-Hi: 400 Hi: 317 Me: 250 Lo: 167 l/s Products Capacity Duct dimension FDUA140AVNXVF Outdoor Power supply 348 FDUA125AVNXVF 506 Note 1 The model name label is attached on the lid of the control box. Outline drawing (Unit:mm) 9 Model FDUM50VF Models FDUM60,71VF FDUA Indoor Unit 10 Duct Connected - High Static Pressure MODELS: FDUA140VF, FDUA160VF MODEL: FDUA200VG Remote control (Options) Wired Wireless DRED enabled model RC-EX1A RC-E5 RCH-E3 Compact design RCN-KIT3-E Drain pump standard enabled. Gravity drainage selectable. 600mm drain pump 379mm Flexible hose less than 600mm ■SW8-4 : ON (Range of use limitation : Setting 10Pa-200Pa) Model FDUA160VF Characteristic FAN (1) Model FDUA160VF Symbol 181 348 Flare 180 Connecting position of the attached connecting pipe liquid side 9.52 3 8" Flare 160 D E F G H Drain hose piece Accessory 1150 Case 2 17.5 284 86 VP25 I.D.25,O.D.32 M10 450X450 12.7 1 2" 22.22 7 8" 150 215 898 Duct dimension C2 H D 600 or less 15 G Me P-Hi 120 Hi 100 Lo Me 80 Setting 60Pa 60 0 30 P-Hi Hi Lo Me Setting 10Pa Lo Lo Me 35 40 1500 Max. drain lift 40 Under 60 111 Setting 120Pa 140 40 45 Hi 55 60 or more 600 Characteristic FAN (2) Range of approvable air flow 200 650 531 498 458 40 200P a 180 180P 160 140 120 Pa 100 120 80 100 Pa Pa 60 80P 40 60P a a 20 506 a 160P a 140 0 46 10P a 47 48 49 50 51 20P a 52 53 Air flow (m3/min) FD series Inverter Packaged Air Conditioners 2015 P-Hi 50 51 Air flow (m3/min) Notes 1) The model name label is attached on the lid of the control box. (2) Connect the piping with local pipe by using the pipe of the attachment. Liquid side and Gas side 61 74 182 181 192 Hi 220 B A 295 325 650 398 370 248 172 472 C1 69 Air supply duct 24 Inspection hole P-Hi Setting 200Pa 20 Control box E Flare Brazing From bottom of unit 28 17.5 Suspension bolts pitch VP25 I.D.25,O.D.32 100 1185 Suspension bolts pitch Drain piping Drain piping Gravity drainage Hole for wiring Suspension bolts Inspection hole Connecting position of the local pipe. liquid side Connecting position of the local pipe. gas side or more 24 Return air duct Hanger plate for suspension bolt Duct dimension 15.88 5 8" B C2 In case actual E.S.P. correspond setting of E.S.P. 200 Connecting position of the attached connecting pipe gas side C1 Installed on site 348 Content A External static pressure (Pa) 898 Duct dimension 26 111 220 External static pressure (Pa) Duct dimension Unit:mm 40P a 54 55 56 FDUA FDUA140AVSXVF Set FDUA160AVSAVF FDUA200AVSAVG Indoor FDUA140VF FDUA160VF FDUA200VG Outdoor FDCA140VSX FDCA160VSA FDCA200VSA Power supply Outdoor Unit 3 Phase 415V 50Hz Cooling T1 kW Heating H1 Cooling T1 Input 16.0 (6.9-20.0) 20.0 (6.9-28.0) 16.0 (4.0-18.0) 18.0 (5.5-22.4) 22.4(5.5-31.5) 4.44 4.83 6.03 4.44 4.66 5.5 3.15 3.31 3.32 kW Heating H1 EER Cooling T1 COP Heating H1 3.6 3.86 4.07 Indoor P-Hi:47 Hi:46 Me:43 Lo:40 P-Hi:49 Hi:48 Me:45 Lo:42 P-Hi:52 Hi:50 Me:47 Lo:45 49 59 Outdoor Sound power level (JIS C9612) dB(A) Outdoor Airflow Indoor l/s External static pressure 73 P-Hi:850 Hi:800 Me:700 Lo:600 P-Hi:850 Hi:800 Me:700 Lo:600 Pa Indoor External dimensions (HXWXD) Indoor Outdoor Refrigerant piping 200 Quantity 89 ■SW8-4 : ON (Range of use limitation : Setting 10Pa-200Pa) 105 Characteristic143 FAN (1) In case actual E.S.P. correcpond setting of E.S.P. Ø9.52 Connection method Refrigerant R410A 1505x970x370 52 mm Gas line 379x1600x893 1300x970x370 kg Liquid line Ø12.7* 240 Ø15.88 Ø22.22 , Ø25.4 or Ø28.58* 220 Flare Connection Setting 200Pa 200 Liquid: Flare / Gas: Brazing* kg 4.5 utomatic external static pressure (E.S.P.) control Maximum pipe length m 100 Pre charged to pipe length m Supply air connection P-Hi:1333 Hi:1200 Me:1067 Lo:933 398x1150x650 mm Outdoor Net weight 59 70 mm 30 External static pressure (Pa) Sound pressure level (JIS C9612) 180 7.2 Setting 120Pa 140 Me P-Hi 70* 120 100 Hi Lo Me 80 60 Model FDUA200VG *Refer to technical manual Model FDUA200VG S.P. FDUM Duct 0 50 ■SW8-4 : ON (Range of use limitation : Setting 10Pa-200Pa) Me 10Pa 20Pa 30Pa 40Pa No.5 50Pa No.6 60Pa No.7 70Pa Setting 120Pa 140 Me P-Hi 120 60 40 80Pa 20 0 50 90 No.9 Me No.10 Lo Hi Me 90Pa 100Pa Lo Hi Me Lo 60 180 200P 160 180P 140 160P 120 140 a a a Pa E.S.P. button 100 Hi Lo Setting 60Pa P-Hi Setting 10Pa P-Hi 70 Air flow proved servicing 80 90 120 Pa 80 100 Pa External static pressure can be set by E.S.P. button. 60 80P 40 60P a 10P 20 0 72 a 76 a a 80 a 40P 20P 84 88 Air flow (m3/min) (m3/min) Characteristic FAN (2) Range of approvable air flow 240 220 200 External static pressure (Pa) unit (impeller and motor) can be pulled from the right side of the unit. ntenance is available from the right side rom beneath. Hi 160 80 No.8 80 200 P-Hi External static pressure (Pa) No.4 External static pressure (Pa) No.3 P-Hi 70 220 Setting 200Pa Keep the 180 same air flow volume No.2 60 240 220 200 No.1 Setting 10Pa Hi Me Range of approvable air flow 240 100 Lo Lo Characteristic FAN (2) In case actual E.S.P. correcpond setting of E.S.P. Ceiling P-Hi Hi Air flow (m3/min) LongerCharacteristic Duct FAN (1) Duct Setting 60Pa 250x1450 Lo 40 20 P-Hi Hi 160 using a DC motor, the optimum air flow volume can be achieved by this automatic control. 348x898 Return air connection mm indoor unit will recognize external static pressure automatically and keep rated RC-E5, RC-EX1A or RCN-KIT3-E Controller flow volume. Safety pan UA-SP2-E (Optional) tting No. Products Capacity 14.0 (5.0-14.5) 180 160 140 120 100 80 60 The fan unit (impeller and motor) can be Unitaccessed easily 200P a Maintenanceand pulled out from 180P a hole the right side of the 160P a unit. Maintenance is 140 Pa accessible from both 120 Service Pa the right side and 100 space Pa underneath the unit Fan unit 80P a 40 60P 10P 20 0 72 Pipe a 76 a a 80 Air flow (m3/min) a 40P 20P 84 88 11 FDUM Indoor Unit 12 Duct Connected - Medium Static Pressure MODELS: FDUM50VF, FDUM60VF, FDUM71VF1, FDUM90VNPVF1, FDUM100VF1, FDUM125VF, FDUM140VF Remote control (Options) Wired Wireless DRED enabled model RC-EX1A RC-E5 RCH-E3 RCN-KIT3-E 600mm Drain Pump Thin design Drain can be discharged upwards by 600mm from the ceiling surface. It allows a piping layout with a high degree of freedom depending on the installation location. The height of all FDUM models is only 280mm. less than 600mm FDUM50/60/71VF C2 31 986 18 Hanger plate for suspension bolt Suspension bolts pitch 950 18 284 81 Control box 4 4 Holes for tapping screws 635 510 471 413 30 M Air supply duct FD series Inverter Packaged Air Conditioners 2015 295 325 D 55 467 4 4 Holes for tapping screws 139 E 880 Duct dimension 55 F G View M 30 Max. drain lift 30 58 67 or less 90 262 170 Hole 76 G 152 124 B A 135 Suspension bolts pitch 113 F 170 C1 69 G 600 472 F 2" Flare 6.35 1 4" Flare VP20 standard:I.D.20, O.D.26 or VP25 Used with attached socket:I.D.25, O.D.34 Note 2 Drain piping VP20 standard:I.D.20, O.D.26 or VP25 C2 Gravity drainage Used with attached socket:I.D.25, O.D.34 D Hole for wiring E M10 Suspension bolts Outside air opening F 150 Knock out for ducting Air outlet opening 125 Knock out G for ducting H 450X450 Inspection hole Notes 1 The model name label is attached on the lid of the control box. 2 Prepare the connecting socket VP20 or VP25 on site. 4 4 Holes for tapping screws 15 262 Drain piping 113 450X450 C1 105 39 Return air duct 14 4 Holes for tapping screw Liquid piping 90 635 510 471 413 170 30 175 31 170 Installed on site Content 12.7 1 B 280 250 Duct dimension 41 200 Drain hose piece Accessory 50 Max. drain lift 76 Symbol A Gas piping 65 46 28 152 Hole 15 50 55 860 Duct dimension 4 200=800 200 125 Knock out View M D 680 Duct dimension 150 Knock out 170 295 325 65 46 M10 139 B A 135 Air supply duct 4 4 Holes for tapping screws 124 C1 600 or less 472 Hole for wiring Suspension bolts Outside air opening for ducting Air outlet opening for ducting Inspection hole H 69 E 43 D E Notes 1 The model name label is attached on the lid of the control box. 2 Prepare the connecting socket VP20 or VP25 on site. 18 284 81 28 750 58 67 170 Drain piping Gravity drainage F Suspension bolts pitch G Duct dimension Suspension bolts pitch C2 G Control box 55 Drain piping 12.7 1 2" Flare 6.35 1 4" Flare VP20 standard:I.D.20, O.D.26 or VP25 Used with attached socket:I.D.25, O.D.34 Note 2 VP20 standard:I.D.20, O.D.26 or VP25 Used with attached socket:I.D.25, O.D.34 43 Return air duct 12 4 Holes for tapping screw C1 105 39 31 Installed on site Gas piping Liquid piping Duct dimension 170 Drain hose piece Accessory F M H 280 Content A B 170 31 65 46 280 250 175 Duct dimension 41 200 660 Duct dimension 200 200 200 786 H 280 FDUM60VF Symbol 18 H 299 Model FDUM60VF Model FDUM50VF Hanger plate for suspension bolt 19mm less H 350 FDUM100/125/140VF FDUM50VF 65 46 70mm less Flexible hose C2 467 Outline drawing (Unit:mm) Model FDUM50VF FDUM Set FDUM50ZMXAVF FDUM60ZMXAVF FDUM71AVNXVF1 FDUM90VNPVF1 FDUM50VF FDUM60VF FDUM71VF1 FDUM100VF1 FDUM100VF1 FDUM125VF FDUM140VF SRC50ZMXA-S SRC60ZMXA-S FDCA71VNX FDC90VNP FDCA100VN FDCA125VNX FDCA140VNX Indoor Outdoor Power supply Outdoor Unit 1 Phase 220-240V 50Hz Cooling T1 Heating H1 Input kW FDUM140VF FDCA140VSX 3 Phase 415V 50Hz 5.0 (2.2-5.6) 5.6 (2.8-6.3) 7.1 (3.2-8.0) 9.0 (1.9-9.0) 10.0 (4.0-11.2) 12.5 (5.0-14.0) 14.0 (5.0-14.5) 14.0 (5.0-14.5) 5.4 (0.6-6.3) 6.7 (0.6-7.1) 8.0 (3.6-9.0) 9.0 (1.9-9.0) 11.2 (4.0-12.5) 14.0 (4.0-17.0) 16.0 (4.0-18.0) 16.0 (4.0-16.5) Heating H2 4.3 4.9 7.0 N/A 11.4 13.7 14.3 Cooling T1 1.56 1.75 2.20 2.65 2.92 3.60 4.40 1.70 2.00 2.20 2.25 3.20 3.90 4.54 kW Heating H1 FDUM140AVSXVF PRODUCTS Capacity FDUM100AVNVF1 FDUM125AVNXVF FDUM140AVNXVF N/A 4.40 4.54 EER Cooling T1 3.21 3.20 3.23 3.40 3.42 3.47 3.18 COP Heating H1 3.18 3.35 3.64 4.00 3.50 3.59 3.52 3.52 Indoor P-Hi:37 Hi:32 Me:29 Lo:26 P-Hi:36 Hi:31 Me:28 Lo:25 P-Hi:38 Hi:33 Me:29 Lo:25 P-Hi:44 Hi:38 Me:36 Lo:30 P-Hi:44 Hi:38 Me:36 Lo:30 P-Hi:45 Hi:40 Me:34 Lo:29 P-Hi:47 Hi:40 Me:35 Lo:30 P-Hi:47 Hi:40 Me:35 Lo:30 50 54 51 55 49 50 49 49 63 64 66 69 72 70 P-Hi: 217 Hi: 167 Me: 150 Lo: 133 P-Hi:333 Hi:250 Me:217 Lo:167 P-Hi: 400 Hi: 316 Me: 250 Lo: 166 P-Hi: 600 Hi: 467 Me: 417 Lo: 317 P-Hi:800 Hi:583 Me:467 Lo:367 P-Hi:800 Hi:583 Me:467 Lo:367 Sound pressure level (JIS C9612) Outdoor Sound power level (JIS C9612) dB(A) Outdoor Airflow Indoor l/s External static pressure 70 Pa Indoor External dimensions (HXWXD) Indoor Net weight Liquid line 280x950x635 640x800(+71)x290 29 280x1370x740 750x880(+88)x340 34 mm Gas line Refrigerant piping 280x750x635 kg Outdoor P-Hi:650 Hi:533 Me:433 Lo:333 100 mm Outdoor P-Hi: 600 Hi: 467 Me: 417 Lo: 317 750x880(+88)x340 845x970x370 1300x970x370 34 54 45 60 57 Ø6.35 Ø9.52 Ø9.52/Ø6.35/Ø6.35 81 105 Ø9.52 Ø12.7 Ø15.88 Connection method Flare Connection Quantity kg 1.5 2.95 2.1 Pre charged to pipe length m 15 30 15 Maximum pipe length m 30 50 30 Supply air connection mm 170x680 170x1200 mm 200x660 235x1280 Return air connection 2 wire or infrared Controller 55 18 284 81 124 B A G 71 170 C1 Hole 180 295 325 104 D 1200 Duct dimension 104 C2 92 45 15 Air supply duct Max. drain lift E 43 467 Hole for wiring Suspension bolts M10 Outside air opening 150 Knock out for ducting Air outlet opening G 125 Knock out for ducting 450X450 H Inspection hole Notes 1 The model name label is attached on the lid of the control box. 4 4 2 Prepare the connecting socket VP20 or VP25 on site. 4 4 Holes for Holes for tapping screws 152 285 tapping screws Control box 59 69 M C2 F Suspension bolts pitch 30 Duct dimension 635 510 471 413 170 Drain piping Drain piping Gravity drainage D E Return air duct 1368 C1 15.88 5 8" Flare 9.52 3 8" Flare VP20 standard:I.D.20, O.D.26 or VP25 Used with attached socket:I.D.25, O.D.34 Note 2 VP20 standard:I.D.20, O.D.26 or VP25 Used with attached socket:I.D.25, O.D.34 139 21.5 24.5 14 4 Holes for tapping screw Content Gas piping Liquid piping 113 24.5 235 205 Installed on site F 530 113 G View M 90 Drain hose piece Accessory 1404 139 or less 880 Duct dimension C2 76 50 D F 30 Max. drain lift 295 325 15 Air supply duct Hole 600 472 E 43 262 170 B A 135 Suspension bolts pitch C1 69 58 67 Duct dimension 152 124 4 4 Holes for tapping screws A B 64 100 28 4 4 Holes for tapping screws 1280 Duct dimension 4 280=1120 280 18 Hanger plate for suspension bolt Suspension bolts pitch 18 284 81 28 950 170 Suspension bolts pitch G 170 D E Air outlet opening 125 Knock out for ducting H 450X450 Inspection hole Notes 1 The model name label is attached on the lid of the control box. 2 Prepare the connecting socket VP20 or VP25 on site. Control box 55 100 Symbol 64 100 G F M C1 C2 F Return air duct 14 4 Holes for tapping screw 9.52 3 8" Flare VP20 standard:I.D.20, O.D.26 or VP25 Used Drain piping with attached socket:I.D.25, O.D.34 Note 2 Drain piping VP20 standard:I.D.20, O.D.26 or VP25 Gravity drainage Used with attached socket:I.D.25, O.D.34 Hole for wiring M10 Suspension bolts Outside air opening 150 Knock out for ducting 105 39 31 170 Installed on site Flare Liquid piping 175 31 Drain hose piece Accessory Duct dimension B Content 15.88 5 8" 23.5 Symbol A Gas piping 65 46 280 250 Duct dimension 41 200 860 Duct dimension 4 200=800 986 50 FDUM100VF, 125VF, 140VF 200 18 30 Models FDUM100VF, 125VF, 140VF FDUM71VF Hanger plate for suspension bolt 4.5 RC-E5, RC-EX1A or RCN-KIT3-E Model FDUM71VF 65 46 3.8 30 600 or less 280 250 184.5 134.5 Refrigerant R410A 3.18 F G View M 90 738 635 468 405 170 30 467 13 EX1A FDTC - Indoor Unit 14 Ceiling Cassette-4way Compact 600x600mm MODELS: FDTC50VF Remote control (Option) Wireless Wired FDTC50VF Remote control (Options) Wired RCH-E3 RC-E5 Wireless RCN-TC-24W-ER DRED enabled model RC-EX1A RC-E5 RCH-E3 RCN-TC-24W-ER Outline drawing (Unit:mm) G G G D A B C F G FD series Inverter Packaged Air Conditioners 2015 FDTC Set FDTC50ZMXAVF Indoor FDTC50VF Outdoor SRC50ZMXA-S Outdoor Unit 1 Phase 220-240V 50Hz Cooling T1 Capacity 5.0(1.1-5.6) Heating H1 Input kW 5.4 (0.6-6.3) Heating H2 5.10 Cooling T1 1.56 kW Heating H1 1.45 EER Cooling T1 COP Heating H1 3.72 Indoor P-Hi:47 Hi:42 Me:36 Lo:30 Sound pressure level (JIS C9612) 3.20 Outdoor Sound power level (JIS C9612) dB(A) 54 P-Hi: 225 Hi: 191 Me: 150 Lo: 133 Outdoor 63 Airflow Indoor l/s Panel TC-PSA-25W-E mm Indoor External dimensions (HXWXD) Indoor 640x800(+71)x290 Unit 15 Panel 3.5 kg Outdoor Liquid line Refrigerant piping 35x700x700 248x570x570 mm Outdoor Net weight 45 Ø6.35 mm Gas line Ø12.7 Connection method Flare connection Quantity Refrigerant R410A Products Power supply kg Pre charged to pipe length Maximum pipe length 1.5 m 15 m 30 Controller RC-E5, RC-EX1A or RCN-TC-24W-ER Quiet operation Taking OA (Outside air intake) into inside Sound Pressure level in the Lo mode (dB) OA Spacer TC-OAS-E (option) (dB) 36 3dB 35dB 36 3dB Joint Duct TC-OAD-E (option) 35 35dB Down 35 Down (dB) 34 Utilizing OA spacer which 36 3dB 35dB34 (dB) 33 (dB) 32dB comes as optional equipment, 35 Indoor Unit FDTC Down 33 36 36 3dB 3dB 32dB Indoor Unit FDTC 35dB 35dB 32 34 32 35 35 Down Down outside air can be taken 31 33 30dB 34 31 34 32dB Indoor Unit FDTC 30dB into inside. 30 33 32 33 30 32dB 32dB Indoor Unit FDTC 31 Indoor Unit FDTC 29 Using 1 joint duct: 32 32 30dB 5dB 29 5dB 300mm 300mm 30 OA 28 3 31 31 28 OA comes up to 1.3m /min.OA 30dBDown Down 30dB 29 Spacer Spacer 30 300mm 27 5dB 27 30 Using 2 joint ducts: OA 28 29 29 Down 26 5dB 26 5dB Spacer 300mm 300mm OA OA 27 Ceiling Ceiling OA OA OA 2.6m3/min. 28 28 OA OA comes from 1.3 to Down 25Down 25 surface surface Spacer Spacer Panel Ceiling OA surface Ceiling OA surface OA Panel Panel Panel Joint Duct Joint Duct Duct OA Ceiling OA Joint surface Joint Duct OA Panel 26 27 25 26 27 Previous Joint Duct (Cooling/Heating) Previous (Cooling/Heating) 25 Previous New Previous 26 (Cooling/Heating) 25(Cooling/Heating) New New(Cooling) (Cooling) (Heating) Previous New New (Cooling) (Cooling/Heating) (Heating) New New (Cooling) (Heating) New (Cooling) New (Heating) New (Heating) Compact and Convenient “CLEARER”Air Flow New shape & angled louver redirects the air current away from the ceiling, to reduce ceiling stains Installation Workability For wireless control simply insert the infrared receiver kit onwireless a corner of the panel wireless 248mm remote wirelesscontrol wirelesswireless 248mm remote control RCN-TC-24W-ER remote control remote remote controlcontrol RCN-TC-24W-ER RCN-TC-24W-ER RCN-TC-24W-ER • 600mm Drain Pump Drain can be discharged upward by 600 mm from the ceiling surface close to the indoor unit. It allows a piping layout with a high degree of freedom depending on the installation location. • 600 x 600 ceiling Indoor unit size (W:570 x D:570) brings easy installation for 600 x 600 ceiling and Panel size (700 x 700) is suitable for 600 x 600 ceiling. Height is one of the industry’s lowest level at 248mm and weight is only 16.5kg. Flexible hose Flexible hose Flexible hose 248mm 600mm 600mm 248mm 248mm Flexible Flexiblehose hose 600mm 600mm 600mm RCN-TC-24W-ER 15 FDT - Indoor Unit 16 Ceiling Cassette-4way MODELS: FDT60VF, FDT71VF1, FDT90VNPVF1, FDT100VF1, FDT125VF, FDT140VF ol (Option) Wired RC-E5 Wireless Remote control (Options) Wired Wireless RCH-E3 RCN-T-36W-E DRED enabled model RC-EX1A RC-E5 RCH-E3 RCN-T-36W-E Outline drawing (Unit:mm) Model FDT 60,71VF Model 100,125,140VF H G H G H H H H H H C B A C F F B A H H D D G G FD series Inverter Packaged Air Conditioners 2015 FDT Set FDT60ZMXAVF Indoor Outdoor Power supply FDT100AVNVF1 FDT125AVNXVF FDT140AVNXVF FDT60VF FDT71VF1 FDT100VF1 FDT100VF1 FDT125VF FDT140VF FDT140VF SRC60ZMXA-S FDCA71VNX FDC90VNP FDCA100VN FDCA125VNX FDCA140VNX FDCA140VSX 5.6 (1.1-6.3) 7.1 (3.2-8.0) 9.0 (1.9-9.0) 10.0 (4.0-11.2) 12.5 (5.0-14.0) 14.0 (5.0-16.0) 14.0 (5.0-16.0) 6.7 (0.6-7.1) 8.0 (3.6-9.0) 9.0 (1.5-9.0) 11.2 (4.0-12.5) 14.0 (4.0-17.0) 16.0 (4.0-18.0) 16.0 (4.0-20.0) 1 Phase 220-240V 50Hz kW FDT140AVSXVF 3 Phase 415V 50Hz Heating H2 5.29 7.2 N/A N/A 15.6 13.8 N/A Cooling T1 1.52 2.04 2.67 2.76 3.28 4.19 4.19 Heating H1 kW 1.70 1.94 2.19 2.74 3.43 4.2 4.20 EER Cooling T1 3.68 3.48 3.37 3.62 3.81 3.34 3.34 COP Heating H1 3.94 4.12 4.11 4.09 4.08 3.81 3.81 Indoor P-Hi:46 Hi:33 Me:31 Lo:30 P-Hi:46 Hi:35 Me:33 Lo:31 P-Hi:51 Hi:40 Me:37 Lo:35 P-Hi:51 Hi:40 Me:37 Lo:35 P-Hi:51 Hi:42 Me:40 Lo:37 P-Hi:51 Hi:43 Me:41 Lo:38 P-Hi:51 Hi:43 Me:41 Lo:38 dB(A) 54 51 55 49 50 52 49 Outdoor 65 66 69 70 70 72 72 Indoor l/s P-Hi: 466 Hi: 300 Me: 266 Lo: 233 P-Hi: 466 Hi: 350 Me: 316 Lo: 283 P-Hi: 617 Hi: 450 Me: 400 Lo: 333 P-Hi: 616 Hi: 450 Me: 400 Lo: 333 P-Hi: 616 Hi: 500 Me: 450 Lo: 383 P-Hi: 616 Hi: 500 Me: 450 Lo: 383 P-Hi: 617 Hi: 500 Me: 683 Lo: 383 Sound pressure level (JIS C9612) Sound power level (JIS C9612) Airflow Outdoor Panel mm External dimensions (HXWXD) Indoor Outdoor Indoor Net weight Outdoor Liquid line Refrigerant piping Gas line mm kg mm T-PSA-3BW-E (35x950x950) 246x840x840 640x800(+71)x290 298x840x840 750x880(+88)x340 Unit 24 Panel 5.5 45 1300x970x370 60 57 Unit 27 Panel 5.5 81 105 Ø6.35 Ø9.52 Ø12.7 Ø15.88 Flare connection Quantity kg 1.5 2.95 2.1 Pre charged to pipe length m 15 30 15 m 30 50 30 Maximum pipe length 845x970x370 Unit 27 Panel 5.5 Connection method Refrigerant R410A Products Heating H1 Input FDT90VNPVF1 Indoor Unit Cooling T1 Capacity FDT71AVNXVF1 Controller 3.8 4.5 30 50 100 RC-E5, RC-EX1A or RCN-T-36W-E Installation Infrared control option Detachable covers at each corner allows for easy alignment and balance. The panel does not need to be removed. Installation time is reduced. For wireless control simply insert the infrared receiver kit on the corner. wireless remote control wireless remote control RCN-T-36W-E RCN-T-36W-E wireless remote remote control control wireless RCN-T-36W-E RCN-T-36W-E Easy checking of drain pan 700mm Drain Pump To check the drain pan simply remove the corner lid. Drain can be discharged upwards by Flexible 700mm from Flexible hose the hose ceiling surface. The 260mm flexible hose is supplied as standard equipment. thanthan Flexiblehose hoselessless Flexible 700mm 700mm lessthan than less 700mm 700mm 17 FDEN - Indoor Unit Ceiling Suspended MODELS: FDEN100VF1, FDEN125VF FDEN 100/125VF Remote control (Options) Wired Wireless DRED enabled model Remote control (Option) RC-EX1A Wired RC-E5 RCH-E3 Wireless RCN-E1R Outline drawing (Unit:mm) RC-EX1A b 40 40 c 52 68 Air outlet 690 195 235 271 75 Liquid piping Gas piping Air inlet grille 110 Drain hole connection(1) (VP20(I.D.20)) 135 Dimension Table model FDEN100~125 a b c d e 1572 1540 1620 255 250 FD series Inverter Packaged Air Conditioners 2015 53 Note(1) The slope of drain piping inside the unit is able to take incline of 10mm. 10 Drain hole connection(1) (VP20(I.D.20)) 76 100 or more 150 or more RCH-E3 RCN-E1R RC-E5 Indication board Space for installation and service Liquid piping Gas piping e d 173 5 135 Holes for suspension bolts (M8 to M10x4pcs.Not included) 410 145 300 or more 290(Suspension bolts pitch) 24 53 109 a (Suspension bolts pitch) 24 308 18 Obstacles Drain hole connection(1) (VP20 (I.D.20)) 5 or more FDEN Set Indoor Outdoor FDEN100VNVF1 FDEN125AVNXVF FDEN100VF1 FDEN125VF FDCA100VN FDCA125VNX Outdoor Unit 1 Phase 220-240V 50Hz Cooling T1 Capacity 10.0 (4.0-11.2) 12.5 (5.0-14.0) 11.2 (4.0-12.5) 14.0 (4.0-17.0) Heating H2 8.7 15.0 Cooling T1 2.85 3.86 2.97 3.77 3.51 3.23 Heating H1 Input Heating H1 kW kW EER Cooling T1 COP Heating H1 3.77 3.71 Indoor P-Hi:46 Hi:44 Me:41 Lo:39 P-Hi:50 Hi:46 Me:44 Lo:43 Sound pressure level (JIS C9612) Outdoor Sound power level (JIS C9612) dB(A) 49 50 Outdoor Airflow Indoor Indoor External dimensions (HXWXD) Outdoor Indoor Net weight Outdoor Liquid line Refrigerant piping Gas line 70 l/s mm kg P-Hi:466 Hi:433 Me:383 Lo:350 845x970x370 1300x970x370 49 81 105 Ø9.52 mm Ø15.88 Flare Connection Quantity kg Pre charged to pipe length m Maximum pipe length P-Hi:533 Hi:483 Me:433 Lo:383 250x1620x690 Connection method Refrigerant R410A Products Power supply m 3.8 4.5 30 50 100 Controller RC-E5, RC-EX1A or RCN-E-E Improved installation workability Increased freedom of a piping layout Up Right Rear The refrigerant pipe from the unit can be arranged in three directions, rear, right and up. The drain pipe can be arranged in two directions, left and right. This will allow a free layout of piping for various installation conditions. The unit can only be serviced from below. Compact and modern design Height 250mm ht All models fit compactly on ceiling. (Height-210mm or 250mm). Plain, modern design featuring rounded edges gives room a comfortable atmosphere. 19 20 SUPERLINK- Control System KX6 series SC-SL1N-E RAC series (SRK/SRF-ZMA-S) SC-BIKN-E SC-ADNA-E SC-SL4AE SC-ADNA-E SC-ADNA-E Central Control SC-SL1N-E SC-SL2NA-E SC-SL4-AE/BE Start/stop control of up to 16 indoor units is possible either individually or collectively. With simple operations, you can effect centralised control. Centralised control of up to 64 indoor units. Allows connection with a weekly timer without using any interface. Easy operation through the large color LCD and touch panel. Up to 128 indoor units can be controlled, when three SUPERLINK-II systems are connected. PC windows central control SC-WGWNA-A/B (SC-WGWNA-B has electric power calculation function) BMS interface unit SC-BGWNA-A/B (LonWorks gateway) Up to 96 cells (some cells can have two or more indoor units and total number of indoor units can be up to 128 units) are controlled centrally from a BMS. Up to 96 indoor units (48 indoor unit x 2) are linked as an open network. Centrally controlled through LonWorks. (SC-WGWN-B has electric power calculation function) Up to 96 cells (some cells can have two or more indoor units and total number of indoor units can be up to 128 units) are controlled from the Internet. Additional engineering service, in the case of SCWGWNB256-A/B up to 256 cells cost is required. Please consult your dealer when using this central control. FD series Inverter Packaged Air Conditioners 2015 SC-LGWNA-A (BACnet gateway) Additional engineering service, in the case of SCWGWNB256-A/B up to 256 cells cost cost is required. In case of SC-BGWN-B, communication test by qualified person regarding electric cost calculation function is required before commissioning. Please Additional engineering service cost is required. Please consult your dealer when using this gateway. SUPERLINK E BOARD (SC-ADNA-E) (1) Functions (a) Transmits the settings from the network option to the indoor units. (b) Returns the priority indoor unit data in response to a data request from the network option. (c) Inspects the error status of connected indoor units and transmits the inspection codes to the network option. (d) A maximum of 16 units can be controlled (if in the same operation mode). (2) Wiring connection diagram Blue A Run Abnormal SL E board A Blue B LED3 LED2 X White Y Y ON SW3 OFF SW2 SW1 Connected to the terminals for Superlink signal lines MVVS 0.75 - 1.25mm2 B Black X Connected to the remote controller terminals (no polarity) (the length should be 600 m or shorter) 200 m or shorter 0.5 mm2 x 2 cores 300 m or shorter 0.75 mm2 x 2 cores 400 m or shorter 1.25 mm2 x 2 cores 600 m or shorter 2.0 mm2 x 2 cores Network address setting switches [000]-(127) Master/Sub address Basic Connections Plural Controls by Multiple Remote Controls. Mixture of Multiple Units Outdoor unit Outdoor unit Internal/external Crossing Internal/external Crossing Indoor unit X Y SL E Board X Y A B Inside Inside Inside Inside Remote control X Y SL E Board Network options Network A B options R R • Transmit the information of plural “Master” units to the network. • Transmit the abnormalities of the “Slave” units to the network. Setting the plural “Master/Slave” units with the dip SW of the printed circuit board. Setting the “Master/Slave” remote controls with the dip SW of the remote control board. Plural Controls by Multiple Remote Controls. Mixture of Multiple Units Outdoor unit Outdoor unit Internal/external Crossing R Inside Inside Inside SL E Board R Network options Without Remote Control Outdoor unit Internal/external Crossing Inside Inside Inside Inside SL E Board CONTROL SYSTEM This board is used when conducting control of the single package (wired remote control unit) 1-type series using a network option (SC-SL1N-E, SC-SL2NA-E, etc). R R Set up “000” to “127” using address switch on the SL E board. Internal/external Crossing Inside Inside SL E Board Network options Set the SL E board dip SW to “Master” SW3-1 ON. The network option SLA-1-E, SL1N-E is not allowed (This will disturb switching of the operation mode) Wireless Kit Outdoor unit Internal/external Crossing Inside Inside SL E Board Network options Wireless Kit Wireless remote control (3) Metal box dimension 85 35 30 70 90 5 22.5 100 40 2-ø6 21 22 Control System Individual Control Remote Control line up indoor unit wired remote control RC-E5 RCH-E3 RC-EX1A all models wireless indoor unit FDT FDTC FDUM, FDU FDEN remote control RCN-T-36W-E RCN-TC-24W-ER RCN-KIT3-E RCN-E-E Wired remote control with weekly timer (option) RC-E5 Run hour metres to facilitate maintenance checking RC-E5 stores operation data when an anomaly occurs and indicates the error on the LCD. It also displays cumulative operation hours of the air conditioner and compressor since commissioning. The RC-E5 controller enables extensive access to service and maintenance technical data combined with easy to use functions and a clear LCD display. Weekly timer function as standard RC-E5 provides (as a standard feature) a weekly timer, which allows one-week operation schedules to be registered. A user can specify up to four times a day to start/stop the air conditioner. (Temperature setting is also possible with the timer). Timer operation Room temperature controlled by the remote control sensor The temperature sensor is housed in the top section of the remote control unit. This arrangement has improved the sensitivity of the remote control unit’s sensor, which permits more finely controlled air conditioning. Changeable set temperature ranges RC-E5 allows the upper and lower limits of a set temperature range to be specified separately. By adjusting a set temperature range, you can ensure energy saving air conditioning by avoiding excessive cooling or heating. Changeable range Upper limit 20~30C(effective for heating operation) Lower limit 18~26C(effective for non-heating operation) Simple remote control (option) RCH-E3 (wired) Considering specialised usage in hotel rooms, control buttons are limited only to minimum required functions such as ON/OFF, mode, temperature setting and fan speed. It is really simple and easy to use. RCH-E3 is not applicable to the Individual flap control system and the Flap control system. When RCH-E3 is used, the fan has 3 speed settings (Hi-Me-Lo) only. Up to 16 units It can control up to 16 units individually, by pressing the AIR CON No. button. AUTO restart This function allows starting the air conditioner automatically when power supply is restored after power failure or by turning on the power switch. Wireless remote control (option) Thermistor (option) SC-THB-E3 For wireless control simply insert the infrared receiver kit on a corner of the panel. RCN-T-36W-E, RCN-TC-24W-ER RCN-KIT3-E When wireless remote control is used, the fan has 3 speed settings (Hi-Me-Lo) only. FD series Inverter Packaged Air Conditioners 2015 RCN-E-E This sensor is used when individual remote control is not required in each room and the system is under central control. By installing sensors in strategic locations through out the structure greater comfort control is achieved. In many instances one additional sensor is all that is required. KXZ-KXR Industry leading energy efficiency and reliability from our advanced technology PRODUCTS Mitsubishi Heavy Industries offers one of the largest ranges of VRF multi inverter products in the industry. The compact M series (11.2 to 15.5kW) is a single fan, single phase outdoor that is providing air conditioning solutions all over Australia and New Zealand. The larger side blow (22.4 to 33.5kW) and top discharge (40 to 68kW) units can be used singularly or in combination to deliver up to 136kW of heat pump or heat recovery technology and energy saving in high rise and mid rise structures. With 16 types of indoor units and 78 different capacities available designs are only limited by imagination. Our eSolution software makes selection simple. The SuperlinkII network can control up to 128 indoor units via a central control or BMS interface such as Web or BACnet gateways. Mente PC can be connected for fault finding and recording test run reports. VRF inverter multi-system Air-Conditioners SR Residential Air Conditioner Mitsubishi Heavy Industries wall mounted and floor standing inverter split systems are the ideal choice to control comfort in any residential situation. Mitsubishi Heavy Industries residential air conditioners have received great reviews in consumer magazines here and overseas when tested and compared to the competitions similar products. Energy efficiency, quite operation and ease of use were the standout differences. SCM Residential Air Conditioner These residential use inverter multi systems can condition 2 to 6 rooms using either wall mounted, floor standing, low static bulkhead or compact cassette type indoor units. The SCM series offers a total of 7 outdoor units and many indoor units making hundreds of different comfort combinations possible. Perfect for homes and apartments. 23 Before starting use Heating performance Refrigerant leakage The heating performance values (kW) described in catalog are the values obtained by operating at an outdoor temperature of 7C and indoor temperature of 20C as set forth in the ISO Standards. As the heating performance decreases as the outdoor temperature drops, if the outdoor temperature is too low and the heating performance is insufficient, use other heating appliances as well. The refrigerant (R410A) used for Air conditioner is non-toxic and nonflammable in its original state. However, in consideration of a state where the refrigerant leaks into the room, measures against refrigerant leaks must be taken in small rooms where the tolerable level could be exceeded. Take measures by installing ventilation devices, etc. Indication of sound values The sound values are the values (A scale) measured in a chamber such as an anechoic chamber following the ISO Standards. In the actual installation state, the value is normally larger than the values given in the catalog due to the effect of surrounding noise and echo. Take this into consideration when installing. Use in oil atmosphere Avoid installing this unit in as atmosphere where oil scatters or builds up, such as in a kitchen or machine factory. If the oil adheres to the heat exchanger, the heat exchanging performance will drop, mist may be generated, and the synthetic resin parts may deform and break. Use in snowy areas Take the following measures when installing the outdoor unit in snowy areas. Snow prevention Install a snow-prevention hood so that the snow does not obstruct the air intake port or enter and freeze in the outdoor unit. Snow piling In areas with heavy snow fall, the piled snow could block the air intake port. In this case, a frame that is 50cm or higher than the estimated snow fall must be installed underneath the outdoor unit. Automatic defrosting device Use in acidic or alkaline atmosphere If this unit is used in acidic atmosphere such as hot spring areas having high level of sulfuric gases or in alkaline atmosphere including ammonia or calcium chloride, places where the exhaust of the heat exchanger is sucked in, or at coastal areas where the unit is subject to salt breezes, the outer plate or heat exchanger, etc., will corrode. Please ask a dealer or specialist when you use an air conditioner in places differing from a general atmosphere. If the temperature is low, and the humidity is high, frost will stick to the heat exchanger of the outdoor unit. If use is continued, the heating performance will drop. The “Automatic defrosting device” will function to remove this frost. After heating for approx, three to ten minutes, it will stop, and the frost will be removed. After defrosting, hot air will be blown again. Use in places with high ceilings Servicing the air-conditioner If the ceiling is high, install a circulator to improve the heat and air flow distribution when heating. After the air-conditioner is used for several seasons, dirt will build up in the air-conditioner causing the performance to drop. In addition to regular servicing, we recommend the maintenance contract (charged for) by a specialist. Safety Precautions Air-conditioner usage target Installation The air-conditioner described in this catalog is a dedicated cooling/heating device for human use. Do not use it for special applications such as the storage of foodstuffs, animals or plants, computer server rooms, precision devices or valuable art, etc. This could cause the quality of the items to drop, etc. Do not use this for cooling vehicles or ships. Water leakage or current leaks could occur. Always commission the installation to a dealer or specialist. Improper installation will lead to water leakage, electric shocks and fires. Make sure that the outdoor unit is stable in installation. Fix the unit to stable base. Before use Always read the “User's Manual” thoroughly before starting use. Usage place Do not install in places where combustible gas could leak or where there are sparks. Installation in a place where combustible gas could be generated, flow or accumulate, or places containing carbon fibers could lead to fires. Only persons that are qualified and licensed are permitted to install and service products that contain refrigerants in Australia, go to www.arctick.org. Suitable access for service must be provided in compliance with industry standards and local regulations. Proudly supporting Australia: New Zealand: ABN 92 133 980 275 G.S.T. 105-673-620 Phone: 1300 138 007 Fax: 1800 644 329 Phone: 0800 138 007 Fax: 09 442 5346 NSW & Head Office Victoria Brisbane Townsville Western Australia Auckland 9C Commercial Road Kingsgrove NSW 2208 PO Box 318 Kingsgrove NSW 1480 2/24 Lakeside Drive Burwood East VIC 3151 5/26 Flinders Parade North Lakes QLD 4509 12/31 Fleming Street Aitkenvale QLD 4812 PO Box 1386 Aitkenvale QLD 4814 Unit 3A 2 Mulgul Rd Malaga WA 6090 PO Box 2089 Malaga WA 6944 Unit 2 100 Bush Road Albany 0632 PO Box 300552 Albany 0632 www.mhiaa.com.au MRE SPARE PARTS www.mrespareparts.com.au Tel: +61 (0) 2 9600 7444 Fax: +61 (0) 2 9600 8044 ISO9001 BIWAJIMA PLANT Mitsubishi Heavy Industries, Ltd. Air-conditioning & Refrigeration Systems Headquarters Certified ISO 9001 Certificate number : JQA-0709 MITSUBISHI HEAVY INDUSTRIESMAHAJAK AIR CONDITIONERS CO., LTD. Certified ISO 9001 Certificate Number : 04100 1998 0813 ISO 14001 Certificate 04104 1998 0813 E5 BIWAJIMA PLANT Mitsubishi Heavy Industries, Ltd. Air-conditioning & Refrigeration Systems Headquarters Certified ISO 14001 Certificate number : JQA-EM0256 MITSUBISHI HEAVY INDUSTRIESMAHAJAK AIR CONDITIONERS CO.,LTD. Certificate Number : 04104 1998 0813 E5 P Our Air Conditioning & Refrigeration Systems Headquarters has been assessed and found to comply with the requirements of ISO14001. nd Lab ou ts a ar 5 Ye a r Wa r r a n ty Because of our policy of continuous improvement, we reserve the right to make changes in all specifications without notice. E&OE. MHIAA446_PAC Series 2015_08 ISO14001 r Our Air Conditioning & Refrigeration Systems Headquarters is an ISO9001 approved factory for residential air conditioners and commercial-use air conditioners (including heat pumps). www.mhiaa.co.nz