Wireless Infrastructure

advertisement
Wireless Infrastructure
Wireless Infrastructure
Solutions for remote radio systems and conventional cell sites
Edition 2011
Count on proven wireless Technology
Your partner for connectivity solutions
The HUBER+SUHNER group is a leading global supplier of components and systems for electrical and optical connectivity. Our
customers in communication, industry and transportation appreciate that we are specialists with detailed knowledge of practical
applications. We offer expertise in radio frequency, fiber optics and
low frequency all under one roof, thus providing a unique basis for
continual innovation which is focused on the needs of our customers
all over the world.
Our motto: “EXCELLENCE in CONNECTIVITY SOLUTIONS”. At the
heart of our offering is a broad range of products that can be relied
on to meet high quality standards, backed up by flexible, dependable services with fast response times worldwide. In the wireless
market, we concentrate on solutions that allow us to stand out by
adding value with special product features, application-specific
innovations, reduction of total cost of ownership and excellence in
delivery performance.
Excellence in Connectivity Solutions
Work with the Leader for Remote Radio Installation Solutions
Remote radio technology
Remote Radio systems evolved as the dominating technology in the wireless communication industry. Remote
radio heads (RRH) significantly reduce the network’s energy consumption while at the same time improving the
network performance. The number of RRH installations surpassed conventional corrugated cell site installations and poses new challenges for operators, installers and system integrators. The installation industry needs
to adapt to new cable technologies, e.g. fiber optics, work with new logistic models, and acquire fundamentally different installation know-how. HUBER+SUHNER helps to build reliable passive infrastructure fulfilling
today’s and tomorrow’s network requirements.
HUBER+SUHNER provides complete installation solutions
HUBER+SUHNER is the global leader for remote radio installation solutions. We have a comprehensive
offering of FTTA (fiber-to-the-antenna) and PTTA (power-to-the-antenna) products which are tailored to the
customer’s needs. We advise operators about which installation methods are available and what are their advantages. We are experts on how to make savings on installation costs and expensive follow-up costs can be
saved. HUBER+SUHNER implements future-proof passive cable network infrastructures which are compatible
with all vendor systems and endure the future generations of active equipment.
Be ready for LTE
LTE systems use remote radio technology. HUBER+SUHNER offers solutions that enables an efficient migration
from corrugated copper systems to RRHs systems while keeping the real-estate changes at the cell site to an
absolute minimum. HUBER+SUHNER has the optimum solution independent of the number or type of RRHs
deployed on the mast.
HUBER+SUHNER
5
Do not compromise your wireless Network Quality
Conventional cell sites technology
HUBER+SUHNER is an established full-range supplier of antenna supply lines for conventional cell-sites
solutions. From SUCOFEED corrugated cables in all sizes with matching easy-to-install QUICK-FIT connectors
on antenna supply lines, to RF LISCA jumpers for connecting the antenna to the network on top of the mast, to
lightning protection solutions of all types and additional products for efficient installation. HUBER+SUHNER
supplies complete updated passive low PIM components for existing or 4th generation LTE applications.
Global design & manufacturing leader of low passive intermodulation components
HUBER+SUHNER’s passive radio frequency components have an outstanding low PIM (passive intermodulation) performance. Our products and material expertise in combination with application know-how enables us
to keep intermodulation in the entire signal path small and to minimize unwanted PIM generated signals in the
uplink. This performance is of particular importance for operators moving to LTE, where frequency bands ranging from 700 MHz up to 2.6 GHz are used in parallel. Our RF products do not compromise your wireless
network performance.
HUBER+SUHNER
7
HUBER+SUHNER – a World Class Supplier for wireless Infrastructure
A guarantee of quality
Continuous quality improvement is a top priority for our organisation. For all our employees, high quality
means the complete fulfilment of all the expectations of our outside and in-house customers. Our systematic
quality and environmental management systems ensure that international standards are observed. Our global
management system is certified according to ISO 9001, ISO 14001 and in our automotive units we also
have ISO/TS 16949.
A truly global company
Market proximity is the advantage of our global presence, with subsidiaries in Australia, Brazil, Canada,
China, Denmark, Germany, France, India, Malaysia, Poland, Singapore, Sweden, Thailand, United Kingdom
and the US plus representatives in over 60 countries. Our customers benefit from all the advantages of a
global supplier, while being supported by local engineering teams, manufacturing and logistics.
Operational excellence
Considerable cost efficiency for us and our customers is made possible by our specialised competence
centres in our three most important markets, namely Europe, the Americas and Asia. Our global, IT-supported
production and logistics operations are managed and coordinated centrally, minimising purchasing and warehousing costs and maximising flexibility with regard to fluctuations in demand. We ensure we are able to meet
the logistic expectations of our customers, independent of high volume bulk shipments or fast and flexible onsite services with short lead-time requirements. Fulfilling challenging expectations for us is a matter of course.
Innovation and competence
We develop superior products and services in close collaboration with our customers. We are one of the few
globally active companies producing components and systems with the key technologies radio frequency,
fiber optics and low frequency under one roof – a unique and necessary combination for the leading solution
provider for remote radio installations. Our production facilities are state of the art; being based in Switzerland,
a hotbed of innovation, and offering high-quality products are both very important factors for us. Our outstanding research and production capabilities mean that we enjoy a great deal of credibility among customers
and stakeholders alike.
Corporate culture
Our corporate culture entails taking the long-term view and keeping an eye on the big picture. The cornerstone
of our present and future success is the dedication shown by our staff, who benefit from competitive employment conditions and attractive career development opportunities. Openness, mutual respect and teamwork are
the means by which we create a working environment where trust and an entrepreneurial spirit reign. Sound
finances and an optimally diversified portfolio of business activities give us the independence to guarantee
continuity within our company.
HUBER+SUHNER
9
Solutions for Cell Sites
Content
Remote radio installation solutions
12
Standard solution with discrete cables
16
Multi-riser cable with distribution box
26
Multi-riser cable with compact divider
44
Re-use of corrugated copper cables
52
Hybrid solutions
60
Fiber optic interfaces for remote radio heads
68
Conventional cell site solutions
82
RF jumpers LISCA
84
SUCOFEED corrugated cables
90
QUICK-FIT coaxial connectors
102
POLYCON lightweight connector
110
Lightning protectors
116
Accessories for conventional cell sites
128
Power splitters
138
Radio frequency antennas and
microwave modules
146
Excellence in Connectivity Solutions
Remote Radio Installation Solutions
Request your best practices guide:
How to install remote radio systems
The installation of remote radio systems poses new challenges for mobile operators, installers and system integrators.
What installation methods are available and what are their advantages? How can a network operator install a futureproof passive infrastructure? How can savings be made on installation costs and follow-up costs? HUBER+SUHNER
offers expert answers to these questions and discusses optimum installation solutions.
Download the White Paper
http://ipaper.ipapercms.dk/HUBERSUHNER/Marketsegments/Communication/RemoteRadioInstallationEN/
Order paper copy of White Paper
HUBER+SUHNER
Item no.
Language
84118113
English version
84118112
German version
13
Overview of RRH Installation Options
Suitable cell sites
#1 Individual cables
#2 Multi-riser cables and box
•Fiber optic: 2-fiber riser cables
•Fiber optic: MASTERLINE classic HT with
6 up to 24 fibers and FTTA Box
•Power supply: 2-wire copper cables
•Power supply: Multi-wire power cable with
grounded PTTA box
See page 16
See page 26
co-located and distributed antennas
only co-located antennas
Flexibility during RRH replacement
no
yes
Scalable for 3 to 12 RRHs
no
yes
Future-proof
no
yes
Overlength management
limited
yes
Installation time
medium
efficient
Cost efficiency / overall costs
€ - €€
€
Spread / frequency in practice
system vendor solution
rapid growth
14
HUBER+SUHNER
Overview of RRH Installation Options
#3 MASTERLINE extreme
•Fiber optic: MASTERLINE extreme with 3
up to 9 break-outs
•Power supply: MASTERLINE extreme
power with multi-wire power cable
See page 44
#4 Re-use of corrugated cables
#5 Hybrid cables
•Fiber optic: MASTERLINE classic HT with
special feed-through cable, 6 to 12 fibers
•Combined fiber optic and power cables
•Power supply: Smart DC kit
See page 52
See page 60
only co-located antennas
only co-located antennas
limited application
yes
yes
no
up to 9 RRHs
up to 6 RRHs
no
yes
yes
no
limited
yes
no
plug&play
efficient
inefficient
€
€
€€€
rapid growth
swap
rarely used under special conditions
HUBER+SUHNER
15
Standard Solution with discrete Cables
The standard solution with discrete cables supports every type of cell site installation whether if the remote radios
are co-located (mast-top installation) or distributed on rooftops of buildings. HUBER+SUHNER has a leading role
in the design and manufacturing of harsh environment connectors (e.g. ODC or Q-XCO) and cable assemblies for
remote radio systems. The installation method with discrete cables is the preferred choice of mobile system vendors
and HUBER+SUHNER is an approved and qualified cable assembly supplier for the majority of the tier 1 and tier 2
vendors.
LISCA RF jumper (page 84)
Overvoltage protection box (optional)
(page 42)
Fiber optic (FTTA) feeder (page 18)
Power supply cable (page 24)
Mounting clamps (page 23 and 128)
Overlength box (page 23)
16
HUBER+SUHNER
Application and features
• Suited for co-located antennas (e.g. mast-top installation) and distributed antennas (e.g. roof-top installation)
• Method supports any type of cell site installation
Benefits
•
•
•
•
•
Simplest and preferred method of system vendors
HUBER+SUHNER deliver customized cable assemblies (e.g. in increments of 10 m)
Vendor approved cable assemblies and guaranteed system compatibility
Short lead-time to fulfil stringent installation requirements
Auxiliary material available for trouble-free installation
Issues
•
•
•
•
•
For three sectors six cables need to be installed
Sub-optimum for longer distances due to time-consuming and complex cable installation
Minor flexibility with regard to RRH or interface replacement
Method does not support system expansions or network evolution
Cables not compatible in case of use of different systems/vendors in same network (e.g. different interfaces or
fiber types).
HUBER+SUHNER
17
FTTA Fiber-to-the-Antenna Feeder
Features
• FTTA feeders available for all types of RRHs and
systems (2G, 3G, 4G, Wimax, Microwave point-topoint links)
• Ruggedized design and installation proof
• Standard assemblies and customized lengths
available in short lead-time
• Cable diameter 4.8mm, 5.5mm or 7mm
• All cables rodent resistant and monkey bite
protected on request
• All cable assemblies factory-terminated and tested
Specifications
Outer cable diameter
4.8 mm
5.5 mm
7 mm
Jacket material
LSFH™
LSFH™
LSFH™
Maximum tensile strength
(during installation/service)
300/500 N
500/1000 N
650/1000 N
Cable crush resistance
(short-term/long-term)
200/400 N/cm
200/400 N/cm
300/1000 N/cm
Temperature range
–40°C to +95°C
–40°C to +80°C
–40°C to +80°C
Flame resistance
IEC 60332-1, IEC 60332-3-24, UL1666
UL approved
None
OFNR
OFNR
UV resistant
yes
yes
Yes
HUBER+SUHNER cables are deployed on a global
scale
Year by year, HUBER+SUHNER produces tens of thousands of FTTA
feeder cables and is globally a leading supplier to major system
vendors and operators. Our customers value our quality products which
are manufactured on all continents close to the local markets.
HUBER+SUHNER is also innovation leader for remote radio interfaces
and is owner of globally successful products like ODC, XCO or
Q-XCO.
18
HUBER+SUHNER
FTTA Fiber-to-the-Antenna Feeder
Ordering information
ODC feeder with Ø 5.5 mm cable
Length
Item no.
singlemode low-bend
Item no.
multimode
Description
1m
84122151
84124943
09H02FG.-..-A4/88-2-1 ..
2m
84122152
84124942
09H02FG.-..-A4/88-2-2 ..
5m
84078725
84078739
09H02FG.-..-A4/88-2-5 ..
10 m
84078726
84078740
09H02FG.-..-A4/88-2-10 ..
15 m
84078727
84078741
09H02FG.-..-A4/88-2-15 ..
20 m
84078728
84078742
09H02FG.-..-A4/88-2-20 ..
30 m
84078729
84078743
09H02FG.-..-A4/88-2-30 ..
40 m
84078730
84078744
09H02FG.-..-A4/88-2-40 ..
50 m
84078731
84078745
09H02FG.-..-A4/88-2-50 ..
60 m
84078732
84078746
09H02FG.-..-A4/88-2-60 ..
70 m
84078733
84078747
09H02FG.-..-A4/88-2-70 ..
80 m
84078734
84078748
09H02FG.-..-A4/88-2-80 ..
90 m
84078735
84078749
09H02FG.-..-A4/88-2-90 ..
100 m
84078736
84078750
09H02FG.-..-A4/88-2-100 ..
125 m
84078737
84078751
09H02FG.-..-A4/88-2-125 ..
150 m
84078738
84078752
09H02FG.-..-A4/88-2-150 ..
ODC feeder also available with 7 mm cable diameter or as 1-fiber version.
LC feeder with metal divider and ruggedized break-out, Ø 5.5 mm cable, low-bend fiber
Length
Item no.
Description
Length
Item no.
Description
1m
84122153
09H02FGG-LB-88/88-2-1.26 NN
60 m
84120595
09H02FGG-LB-88/88-2-60.26 NN
2m
84122154
09H02FGG-LB-88/88-2-2.26 NN
70 m
84120596
09H02FGG-LB-88/88-2-70.26 NN
5m
84120589
09H02FGG-LB-88/88-2-5.26 NN
80 m
84120597
09H02FGG-LB-88/88-2-80.26 NN
10 m
84120590
09H02FGG-LB-88/88-2-10.26 NN
90 m
84120598
09H02FGG-LB-88/88-2-90.26 NN
20 m
84120591
09H02FGG-LB-88/88-2-20.26 NN 100 m
84120599
09H02FGG-LB-88/88-2-100.26 NN
30 m
84120592
09H02FGG-LB-88/88-2-30.26 NN
125 m
84120600
09H02FGG-LB-88/88-2-125.26 NN
40 m
84120593
09H02FGG-LB-88/88-2-40.26 NN 150 m
84120601
09H02FGG-LB-88/88-2-150.26 NN
50 m
84120594
09H02FGG-LB-88/88-2-50.26 NN
Also available with 4.8 mm cable.
HUBER+SUHNER
19
FTTA Fiber-to-the-Antenna Feeder
LC feeder with Ø 7 mm cable
Item no.
singlemode low-bend
Item no.
multimode
Description
1m
84106141
84117532
09H02FG.-..-88/88-2-1 ..
2m
84106142
84085209
09H02FG.-..-88/88-2-2 ..
3m
84106143
84114473
09H02FG.-..-88/88-2-3 ..
4m
84125503
84125500
09H02FG.-..-88/88-2-4 ..
5m
84105041
84085208
09H02FG.-..-88/88-2-5 ..
6m
84125504
84125501
09H02FG.-..-88/88-2-6 ..
Length
8m
84125507
84125502
09H02FG.-..-88/88-2-8 ..
10 m
84104280
84115234
09H02FG.-..-88/88-2-10 ..
15 m
84106144
84115236
09H02FG.-..-88/88-2-15 ..
20 m
84106145
84085207
09H02FG.-..-88/88-2-20 ..
30 m
84106146
84085200
09H02FG.-..-88/88-2-30 ..
40 m
84106147
84085201
09H02FG.-..-88/88-2-40 ..
50 m
84106148
84085202
09H02FG.-..-88/88-2-50 ..
60 m
84106149
84124945
09H02FG.-..-88/88-2-60 ..
70 m
84106150
84085203
09H02FG.-..-88/88-2-70 ..
80 m
84106151
84084612
09H02FG.-..-88/88-2-80 ..
90 m
84106152
84124946
09H02FG.-..-88/88-2-90 ..
100 m
84106153
84085204
09H02FG.-..-88/88-2-100 ..
125 m
84106154
84124947
09H02FG.-..-88/88-2-125 ..
150 m
84106155
84085205
09H02FG.-..-88/88-2-150 ..
200 m
84124944
84085206
09H02FG.-..-88/88-2-200 ..
Item no.
singlemode low-bend
Item no.
multimode
Description
84122419
84122420
09H02FG.-..-88/88-2-2.5 ..
LC feeder with Ø 5.5 mm cable
Length
2.5 m
5m
84122418
84104136
09H02FG.-..-88/88-2-5 ..
15 m
84104111
84104137
09H02FG.-..-88/88-2-15 ..
30 m
84104112
84104138
09H02FG.-..-88/88-2-30 ..
50 m
84104113
84104139
09H02FG.-..-88/88-2-50 ..
70 m
84104114
84104140
09H02FG.-..-88/88-2-70 ..
85 m
84104115
84104142
09H02FG.-..-88/88-2-85 ..
100 m
84104116
84104143
09H02FG.-..-88/88-2-100 ..
150 m
84104117
84104144
09H02FG.-..-88/88-2-150 ..
200 m
84104118
84104145
09H02FG.-..-88/88-2-200 ..
250 m
84104120
84104146
09H02FG.-..-88/88-2-250 ..
300 m
84104121
84104147
09H02FG.-..-88/88-2-300 ..
20
HUBER+SUHNER
FTTA Fiber-to-the-Antenna Feeder
LC feeder with 90° boot, Ø 7 mm cable, multimode fiber
Only available for vendor approved companies.
Length
Item no.
Description
2m
84082925
09H02FG0-50-8C/8C-2-2 MM
5m
84122156
09H02FG0-50-8C/8C-2-5 MM
10 m
84083054
09H02FG0-50-8C/8C-2-10 MM
20 m
84083071
09H02FG0-50-8C/8C-2-20 MM
30 m
84083074
09H02FG0-50-8C/8C-2-30 MM
40 m
84083079
09H02FG0-50-8C/8C-2-40 MM
50 m
84083081
09H02FG0-50-8C/8C-2-50 MM
75 m
84083084
09H02FG0-50-8C/8C-2-75 MM
100 m
84083086
09H02FG0-50-8C/8C-2-100 MM
200 m
84083087
09H02FG0-50-8C/8C-2-200 MM
LC feeder with straight boot, Ø 7 mm cable
Only available for vendor approved companies.
Item no.
singlemode low-bend
Item no.
multimode
Description
1m
84124936
84124933
09H02FG.-..-8A/88-2-1 ..
2m
84124937
84124024
09H02FG.-..-8A/88-2-2 ..
Length
5m
84124938
84124054
09H02FG.-..-8A/88-2-5 ..
10 m
84125616
84123456
09H02FG.-..-8A/88-2-10 ..
15 m
84125617
84124055
09H02FG.-..-8A/88-2-20 ..
20 m
84125618
84124056
09H02FG.-..-8A/88-2-30
30 m
84062386
84124057
09H02FG.-..-8A/88-2-30 ..
50 m
84062387
84062408
09H02FG.-..-8A/88-2-50 ..
70 m
84062388
84062409
09H02FG.-..-8A/88-2-70 ..
90 m
84062389
84062410
09H02FG.-..-8A/88-2-90 ..
110 m
84062390
84062411
09H02FG.-..-8A/88-2-110 ..
130 m
84062391
84062412
09H02FG.-..-8A/88-2-130 ..
150 m
84062392
84062413
09H02FG.-..-8A/88-2-150 ..
170 m
84062393
84062414
09H02FG.-..-8A/88-2-170 ..
190 m
84062394
84062415
09H02FG.-..-8A/88-2-190 ..
210 m
84062395
84062416
09H02FG.-..-8A/88-2-210 ..
HUBER+SUHNER
21
FTTA Fiber-to-the-Antenna Feeder
ODC-4 feeder with Ø 5.5 mm cable
Length [m]
Fiber type
Description
L
singlemode low-bend
09H04FGG-LB-J2/88-3-L NN
L
multimode
09H04FG0-50-J2/88-3-L MM
Q-XCO feeder with Ø 5.5 mm cable
Length [m]
Fiber type
Description
L
singlemode low-bend
09H02FGG-LB-XA/88-2-L NN
L
multimode
09H02FG0-50-XA/88-2-L MM
Length [m]
Fiber type
Description
L
singlemode low-bend
09H02FGG-LB-X1/88-2-L NN
L
multimode
09H02FG0-50-X1/88-2-L MM
XCO feeder with Ø 5.5 mm cable
Further FTTA feeders for all types of remote radio systems available (e.g. R2CT, LC push-pull connector, industrial LC connector).
22
HUBER+SUHNER
FTTA Fiber-to-the-Antenna Feeder
Installation accessories
Description
Features
Item number
• outdoor installation
Excess length boxes
• store up to 20 m cable excess length
84103325
• easy mountable
1 cable, diameter 5 – 6 mm
84079464
1 cable, diameter 6 – 7 mm
84079465
3 cables, diameter 5 – 6 mm
84079466
3 cables, diameter 6 – 7 mm
84079467
Cable mounting clamps
HUBER+SUHNER
23
Power Supply Cable
Features
•
•
•
•
•
DC copper cable for RRH power supply
2 shielded copper wires
Cross section 4 mm2, 6 mm2, 10 mm2, 16 mm2
Suited for all remote radio systems
Raw cable or preconnected cable assemblies
available
• For indoor and outdoor application
Specifications
Jacket material
LSFH™
Conductor
tinned copper stranded
Braid
tinned copper
Tensile strength
1000 N
Bending radius
200 mm
Temperature range
–40°C to +70°C
Operating voltage
48 V DC
Breakdown voltage
2000 VRMS, 60 Hz, 1 minute between conductors
Current per conductor
max. 15 Amp (30 Amp @ 16mm2)
Resistance
max. 4.86 Ω/km @ 4 mm2
max. 3.27 Ω/km @ 6 mm2
max. 1.92 Ω/km @ 10 mm2
max. 1.22 Ω/km @ 16 mm2
Ordering information
Cross section
Cable diameter
Item no.
Description
2
2 x 4 mm
9.4 mm
84119282
0204-03-LSFH15-01
2 x 6 mm2
10.6 mm
84112973
0206-03-LSFH15-01
2 x 10 mm
14 mm
84112975
0210-03-LSFH20-01
2 x 16 mm
19.6 mm
84115986
0216-03-LSFH20-01
2
2
Connectorized power cable assemblies available upon request.
24
HUBER+SUHNER
HUBER+SUHNER
25
Multi-riser Cable with Distribution Box
This solution uses multi-riser cables for fiber optic and copper that are routed in separate connection boxes (or in a
combined hybrid box) which are then linked to the RRHs with short jumper cables. This installation method is costeffective and installation friendly and is therefore the preferred choice of mobile network operators who have control
over network design and deployment. The passive cable infrastructure is future-proof, supports network expansions
and saves on installation and follow-up costs. HUBER+SUHNER is a complete solution provider and manufacturer for
the passive cable infrastructure between base station and antenna.
LISCA RF jumper (page 84)
RRH jumper (page 34)
Power jumper (page 51)
FTTA box (page 28)
PTTA box (page 40)
MASTERLINE classicHT (page 30)
Power feeder (page 36)
CTB 19" termination box [optional]
(page 55)
LC patchcord [optional]
(page 55)
26
HUBER+SUHNER
Application and features
•
•
•
•
Optimum for co-located antennas, e.g. mast-top installation
Preferred method of network operators
Passive cable infrastructure is system and vendor independent
Cable installation systems designed for 20-years life time to support network evolution over future generations of
active equipment
Benefits
•
•
•
•
•
•
Reduced installation times, lower level of investment (CAPEX)
For 3-sector site, just 2 multi-riser cables instead of 6 individual cables, plug-and play
Scalable for 3 up to 12 RRHs, perfect for planned LTE roll-outs and expansions
Future-proof as the passive cable infrastructure supports all aspects of network evolution
Best flexibility in case of RRH replacement as short jumpers can be easily exchanged
HUBER+SUHNER designs and delivers complete systems
Issues
• Limited suitability for cell sites with distributed antennas
HUBER+SUHNER
27
FTTA Fiber-to-the-Antenna Box
Features
•
•
•
•
Ruggedized outdoor fiber distribution box
Supports up to 8/12 remote radio heads
Fitted with bend radius limiting mandrels
Suitable for mounting on poles, walls and tower
legs with round-, L-, V- and -shape.
• Easy to mount and install with integrated screws and
pre-mounted brackets
• Compatible with splice cassettes and MTP modules
• Fully electrically isolated / RoHs compliant
Specifications
small FTTA box
medium FTTA box
Number of RRH
3, 6, 8 RRH
up to 12 RRH
Compatible with MASTERLINE
6, 12, 16 fibers
24 fibers
Dimensions
255 x 180 x 65 mm
230 x 300 x 85 mm
Cable entry (left knock-out holes)
2 x M16 for MASTERLINE small
1 x M26 for MASTERLINE
medium
Cable exit (right knock-out holes)
2 x M25 for 3-fold cable gland
2x M32 for 6-fold cable gland
Material
glass-filled polycarbonate, halogen free
Material flammability rating
UL 94 HB
Ingress protection
IP 66/67 (EN 60529), NEMA 1, 4, 4X, 6, 12 and 13
Impact resistance
IK 07 (EN 62262)
Operating temperature range
–40°C to +85°C
Customized or hybrid boxes are available upon request.
HUBER+SUHNER’s MASTERLINE solution is a
win for LTE
The multi-fiber cabling and box solution makes the infrastructure easier
to deploy, reduces field failures, and supports multi-vendor installations.
By installing additional fibers, the sites are ready for LTE roll-outs and
scalable for future applications.
Global and local operators are convinced of the benefits of this
cabling system. Therefore, names like Vodafone, T-Mobile,
Telenor, Bouygues Telecom and many others trust and rely on
HUBER+SUHNER’s MASTERLINE solution to make their passive
infrastructure future-proof, scalable and ready for LTE.
28
HUBER+SUHNER
FTTA Fiber-to-the-Antenna Box
Ordering information and accessories
Description
Feature
Item no.
Small FTTA box
up to 16 fibers
84074085
Medium FTTA box
up to 24 fibers
84112317
3 LC duplex adapter, nut for
MASTERLINE, cable gland
3 x Ø 5.5 mm and Ø 7.0 mm,
laser label, 2 blind plugs
84121039
6 LC duplex adapter, nut for
MASTERLINE, 2 cable glands
3 x Ø 5.5 mm and Ø 7.0 mm,
laser label, 2 blind plugs
84121040
singlemode
84083886
multimode
84090245
M16 up to 12 fibers
23040540
M26 up to 24 fibers
23236878
3 x cable Ø 5.5 – 7.0 mm
84121958
4 x cable Ø 5.5 mm
84121959
6 x cable Ø 5.5 - 7.0 mm
84113000
Installation kit for 3 RRH,
singlemode
Installation kit for 3 RRH,
multimode
Installation kit for 6 RRH,
singlemode
Installation kit for 6 RRH,
multimode
Picture
for small FTTA box
84121041
for medium FTTA box
84121042
LC duplex adapter
Nut for MASTERLINE
Cable gland M25
(for small box)
Cable gland M32
(for medium box)
Blind plugs for cable gland
84090788
clamping diameter 30 – 155 mm 84076411
Quick hose clamp
(stainless steel)
clamping diameter 60 – 500 mm 84076412
N-Ventil
(for pressure equalization)
HUBER+SUHNER
23038472
29
Fiber Optic MASTERLINE classicHT*
Features
•
•
•
•
•
Pre-assembled plug&play cabling system
Ruggedized design with robust pulling tube
Outdoor and indoor with high flame resistance
Temperature range –40 °C up to +75 °C
Loose tube cables with up to 24 fibers, rodentprotected and UV resistant
• Fibers and connectors colour coded for easy
channel identification
• Easy and time-saving installation
• Each system factory tested
*HT = High Temperature
Specifications
Number of fibers
up to 12
up to 24
Divider
small
medium
Build-in hole dimension
15.6 -16.4 mm
25.5 - 26.5 mm
Outer diameter
23.5 mm
31 mm
Maximum tensile strength
1000 N
1000 N
Crush resistance
250 N/cm
250 N/cm
Ingress protection
IP 67
IP 67
Pulling tube with pulling eye
Glass-armoured loose-tube cable
Jacket material
LSFH™
Cable diameter
2- 24 fibers
8.5 mm
Tensile strength
during installation
in service
3000 N
1500 N
Crush resistance
short-term
long-term
400 N/cm
200 N/cm
Temperature range
installation
service
–25°C to 75°C
–40°C to 75°C
Flame resistance
IEC 60332-1
IEC 60332-3-24
passed
pulling tube (screwed down)
divider with thread and mounting groove
pulling eye for installation
seal ring
installed length pigtail:
30
pulling tube (tread-proof, waterproof)
shortest length
longest length
HUBER+SUHNER
Fiber Optic MASTERLINE classicHT
Standard portfolio
• MASTERLINE classicHT with 6, 12, and 24 fibers
• Both sides terminated with colour coded LC duplex connectors
• Small FTTA box compatible for 6 and 12 fibers, medium FTTA box for 24 fibers
Colour coding
RRH 1+7
RRH 2+8
RRH 3+9
RRH 4+10
RRH 5+11
RRH 6+12
red
green
blue
yellow
white
black
Ordering information
MASTERLINE classicHT
6 fibers
3 RRH
Length
Fiber type
12 fibers
6 RRH
24 fibers
12 RRH
Item number
20 m
84117833
84117846
84117858
30 m
84117834
84117847
84117859
40 m
84117835
84117848
84117860
50 m
84117836
84117849
84117861
60 m
84117837
84117850
84117862
70 m
84117838
84117851
84117863
84117839
84117852
84117864
80 m
singlemode
90 m
84117840
84117853
84117865
100 m
84117841
84117854
84117866
125 m
84117842
84117855
84117867
150 m
84117843
84117856
84117868
200 m
84117845
84117857
84117869
20 m
84117870
84117882
84117895
30 m
84117871
84117883
84117896
40 m
84117872
84117884
84117897
50 m
84117873
84117885
84117898
60 m
84117874
84117886
84117899
84117875
84117887
84117900
84117876
84117888
84117901
84117877
84117889
84117902
100 m
84117878
84117890
84117903
125 m
84117879
84117891
84117904
150 m
84117880
84117892
84117905
200 m
84117881
84117894
84117906
70 m
80 m
90 m
HUBER+SUHNER
multimode OM2
31
Fiber Optic MASTERLINE MPO / MTP ™
Features
•
•
•
•
•
•
Pre-assembled plug&play cabling system
MTP connector with up to 12 fibers
Ruggedized design with robust pulling tube
Outdoor and indoor with high flame resistance
Temperature range –40 °C up to +75 °C
Loose tube cables, rodent-protected and UV
resistant
• Easy and time-saving installation
• Each system factory tested
• Compatible with FTTA boxes in combination with
MTP cassette
Specifications
Number of fibers
up to 12
up to 24
Number of MTP connectors (without pins)
1
2
Compatibility
small FTTA Box
medium FTTA Box
MASTERLINE divider
small Ø 16 mm
small Ø 16 mm
adapter required to fit M26
cable entry
Whip cable diameter
3.5 mm
Pulling tube with pulling eye
Outer diameter
23.5 mm
Maximum tensile strength
1000 N
Crush resistance
250 N/cm
Ingress protection
IP 67
MTP Module for FTTA Box
Features
• Pre-assembled MTP fiber module with fan-out to
LC duplex adapters
• Compatible to mount in small FTTA box
• With 6 and 12 fibers available (3 and 6 RRHs)
• LC adapters colour-coded
Ordering information (module only / without box)
Description
Number of fibers
Fiber type
Item no.
MTP module, 6-fiber MTP (in),
3 x LC duplex adapter (out)
6
singlemode
84122225
6
multimode
84122226
MTP module, 12-fiber MTP (in),
6 x LC duplex adapter (out)
12
singlemode
84122227
12
multimode
84122228
32
HUBER+SUHNER
MASTERLINE MTP™ Standard Portfolio
Ordering information
MASTERLINE MTP to MTP
Singlemode
Length
Multimode
6 fibers – 3 RRH
12 fibers – 6 RRH
6 fibers – 3 RRH
12 fibers – 6 RRH
20 m
84121976
84121988
84122000
84122012
30 m
84121977
84121989
84122001
84122013
40 m
84121978
84121990
84122002
84122014
50 m
84121979
84121991
84122003
84122015
60 m
84121980
84121992
84122004
84122016
70 m
84121981
84121993
84122005
84122017
80 m
84121982
84121994
84122006
84122018
90 m
84121983
84121995
84122007
84122019
100 m
84121984
84121996
84122008
84122020
125 m
84121985
84121997
84122009
84122021
150 m
84121986
84121998
84122010
84122022
200 m
84121987
84121999
84122011
84122023
6 fibers – 3 RRH
12 fibers – 6 RRH
6 fibers – 3 RRH
12 fibers – 6 RRH
20 m
84122024
84122036
84122048
84122060
30 m
84122025
84122037
84122049
84122061
MASTERLINE classic HT to MTP
Singlemode
Length
Multimode
40 m
84122026
84122038
84122050
84122062
50 m
84122027
84122039
84122051
84122063
60 m
84122028
84122040
84122052
84122064
70 m
84122029
84122041
84122053
84122065
80 m
84122030
84122042
84122054
84122066
90 m
84122031
84122043
84122055
84122067
100 m
84122032
84122044
84122056
84122068
125 m
84122033
84122045
84122057
84122069
150 m
84122034
84122046
84122058
84122070
200 m
84122035
84122047
84122059
84122071
HUBER+SUHNER
33
RRH Jumpers
Features
• Jumper available for all types of RRH
• Cable diameter 4.8 mm, 5.5 mm or 7 mm
• Standard lengths of 1, 2 or 5 m, any customized
length available.
• On request, colour coded jumpers for easy
installation available.
Ordering information and accessories
Jumper description
•ODC plug - LC duplex
•Cable Ø 5.5 mm
•LC jumper with metal divider
•Cable Ø 5.5 mm
•LC duplex jumper
•Cable Ø 7 mm
Item no.
Singlemode low-bend
Item no.
Multimode
1m
84122151
84124943
2m
84122152
84124942
5m
84078725
84078739
1m
84122153
–
2m
84122154
–
5m
84120589
–
1m
84106141
84117532
2m
84106142
84085209
5m
84105041
84085208
2.5 m
84122419
84122420
5m
84122418
84104136
2m
–
84124939
5m
–
84124940
10 m
–
84124941
1m
84124936
84124933
2m
84124937
84124024
5m
84124938
84124054
Length
Picture of RRH connector (second connector
LCD)
•LC duplex jumper
•Cable Ø 5.5 mm
•LC boot jumper
•Cable Ø 7 mm
•LC boot jumper – straight
•Cable Ø 7 mm
Further jumpers for all types of remote radio systems available (e.g. Q-XCO, XCO, R2CT, LC push-pull connector, industrial LC connector).
34
HUBER+SUHNER
PTTA Power-to-the-Antenna Box
Features
• Ruggedized outdoor power distribution box
• Supports 3 or 6 remote radio heads
• DIN rail to mount clamps, circuit breakers or surge
protectors
• Robust power cable entry/exit
• Optional cable entry for grounding
• Suitable for mounting on poles, walls and tower
legs with round, L, V and -shape.
• Easy to mount and install with integrated screws and
pre-mounted brackets
• Compatible with all common power cables
• Fully electrically isolated / RoHs compliant
Specifications
Small PTTA box
Medium PTTA box
Number of RRH
3 RRH
6 RRH
Compatibility
Common power cables and Smart DC Kit
Dimensions
255 x 180 x 110 mm
230 x 300 x 110mm
Cable entry
(left knock-out holes)
1 x M32
for power multiwire cable
2 x M32
for power multiwire cable
Cable exit
(right knock-out holes)
3 x M20
for power jumpers
6 x M20
for power jumpers
Grounding (knock-out hole)
M16
M16
Material
Glass-filled polycarbonate, halogen free
Material flammability rating
UL 94 HB
Ingress protection
IP 66/67 (EN 60529), NEMA 1, 4, 4X, 6, 12 and 13
Impact resistance
IK 07 (EN 62262)
Operating temperature range
–40 °C to +85 °C
Ordering information and accessories
Description
Small PTTA box
available in Q2/2011
Medium PTTA box
available in Q3/2011
Cable glands
for PTTA boxes
Quick hose clamp (stainless steel)
Feature
Item no.
up to 3 RRH
84125862
up to 6 RRH
84125865
M32, cable Ø 13 – 20 mm
84125911
M20, cable Ø 6 – 12 mm
84125912
M16, cable Ø 4 – 8 mm
84125913
clamping diameter 30 – 155 mm
84076411
clamping diameter 60 – 500 mm
84076412
Picture
Customized or hybrid boxes are available upon request.
HUBER+SUHNER
35
Power Multiwire and Jumper Cables
Features
•
•
•
•
•
DC copper cable for RRH power supply
6 copper wires
Cross section 6 mm2 and 10 mm2
Suited for all remote radio systems
Raw cable or connectorized cable assemblies
available
• For indoor and outdoor application
Specifications
Jacket material
LSFH™
Conductor
tinned copper stranded
Braid
tinned copper
Tensile strength
1000 N
Bending radius
200 mm
Temperature range
–40°C to +70°C
Operating voltage
48 V DC
Breakdown voltage
300 VRMS, 60 Hz, 1 minute between conductors
Current per conductor
max. 15 Amp
Resistance
max. 3.27 Ω/km @ 6 mm2
max. 1.92 Ω/km @ 10 mm2
Ordering information
6 wire power cable - connection between base station and PTTA box
Cross section
Cable diameter
Item no.
Description
6 x 6 mm
14.50 ± 0.50 mm
84119330
0606-03-LSFH15-01
6 x 10 mm
19.20 ± 0.80 mm
84119329
0610-03-LSFH20-01
2
2
2 wire power jumper – connection from PTTA box to RRH
Cross section
Cable diameter
Item no.
Description
2 x 4 mm2
9.4 mm
84119282
0204-03-LSFH15-01
2 x 6 mm2
10.6 mm
84112973
0206-03-LSFH15-01
Connectorized power cable assemblies available upon request.
Power Supply Cable
Features
•
•
•
•
•
DC copper cable for RRH power supply
2 shielded copper wires
Cross section 4 mm2, 6 mm2, 10 mm2, 16 mm2
Suited for all remote radio systems
Raw cable or connectorized cable assemblies
available
• For indoor and outdoor application
For specifications see page 24.
36
HUBER+SUHNER
Overvoltage Protection (OVP)
Overvoltage protection / type 1, class I
Features
Type 9079.99.002
Type 9079.99.003
• Solution for lightning protection
• Lighting current arrestors type 1, class I coordinated
spark gap technology with 35 kA (10/350 µs)
current discharge capacity
• Low voltage protection level
• Load current = 80 A (DC) maximum
• Operating state / fault indication by indicator flag
and with remote signalling contacts for the
monitoring system
• Easy replacement of protection modules without
tools due to special locking system
• Vibration- and shock- tested according to
EN 60068-2
Specifications see page 38.
Overvoltage protection / type 2, class II
Features
Type 9079.99.001
• Solution for surge protection
• Surge arrestor type 2, class II capable of handling
40 kA (8/20 µs) maximum discharge current due to
deployed heavy-duty zinc oxide varistor
• High reliability based on a "thermo dynamic
control" SPD monitoring device
• Low voltage protection level
• Operating state / fault indication by indicator flag
and with remote signalling contacts for the
monitoring system
• Easy replacement of protection modules without
tools due to special locking system
• Vibration- and shock-tested according to
EN 60068-2
Specifications see page 39.
HUBER+SUHNER
37
Overvoltage Protection (OVP)
Specifications for type 1, class I (10/350 µsec) solution
RRH- DC protection circuits for
48 V DC, (60 V max., 80 A)
Outdoor box (at RRH)
Indoor box (base station)
OVP circuit description
OVP circuit description:
2XWGRRU%R[
,QGRRU%R[
²
²
1<&:<[PPVFUHHQHG
SPD acc.
EN 61643-11: type 1
IEC 61643-1: class 1
Outdoor protection:
9
'&
55+
•OVP circuit 9079.99.003
Indoor protection:
•OVP circuit 9079.99.0002
$&
3(6FUHHQ
3(6FUHHQ
9'&²55+0DVW
Electrical data
1RWH
SROHLVFRQQHFWHGZLWKJURXQG
LQWKH9UHIOHFWLHU
9'&²5HFWLILHU
9079.99.0002M
9079.99.0004M
9079.99.0002M
Max. continuous operating
voltage AC (Uc)
150 V
255 V
150 V
Lightning impulse current
(10/350 µs) Iimp
35 kA
100 kA
35 kA
Nominal discharge current
(8/20 µs) In
35 kA
100 kA
35 kA
Voltage protection level Up
Response time tA
Max. backup fuse (L–L’)
1.5 kV
1.5 kV
1.5 kV
≤100ns
≤100ns
≤100ns
125 A gL/gG
–
125 A gL/gG
Specifications
Operating temperature range
–40°C…+60°C
Operating state / fault indication
green / red
Cross-sectional area min.
10 mm2 solid / flexible
Cross-sectional area max.
50 (35) mm2 stranded / 35 (25) mm2 flexible
For mounting on
35 mm DIN rail acc. to EN 60715
Enclosure material
thermoplast, red, UL 94 V-0
Degree of protection
Capacity
IP 20
4 modules, DIN 43880
Type of remote signalling contact
2 modules, DIN 4380
changeover contact
Switching capacity AC
250 V/0.5 A
Switching capacity DC
250 V/0.1 A; 125 V/0.2 A; 75 V/0.5 A
Cross-sectional area remote
signal terminal
max. 1.5 mm2 solid / flexible
Ordering information / type
OVP unit
Module
38
9079.99.0003
9079.99.0002M
9079.99.0004M
9079.99.0002
9079.99.0002M
HUBER+SUHNER
Overvoltage Protection (OVP)
Specifications for type 2, class II (8/20 µsec) solution
Outdoor box (at RRH)
Indoor box (base station)
OVP circuit description
OVP circuit description:
2XWGRRU%R[
RRH- DC protection circuits for 48
V DC, (60 V max., 80 A)
SPD acc.
EN 61643-11: type 2
IEC 61643-1: class II
Outdoor protection:
,QGRRU%R[
²
²
1<&:<[PPVFUHHQHG
9
'&
55+
•Two OVP circuits 9079.99.001
Indoor protection:
•One OVP circuit 9079.99.001
3(6FUHHQ
3(6FUHHQ
9'&²55+0DVW
Electrical data
$&
1RWH
SROHLVFRQQHFWHGZLWKJURXQG
LQWKH9UHIOHFWLHU
9'&²5HFWLILHU
9079.99.0001M
9079.99.0001M
9079.99.0001M
Max. continuous operating
voltage AC (Uc)
100 V
100 V
100 V
Max. discharge current
(8/20 µs) Imax
40 kA
40 kA
40 kA
Nominal discharge current
(8/20 µs) In
10 kA
10 kA
10 kA
Voltage protection level Up
≤0.4kV
≤0.4kV
≤0.4kV
Response time tA
≤25ns
≤25ns
≤25ns
125 A gL/gG
125 A gL/gG
125 A gL/gG
Max. backup fuse (L–L’)
Specifications
Operating temperature range
–40°C…+80°C
Operating state / fault indication
green / red
Cross-sectional area min.
1.5 mm2 solid / flexible
Cross-sectional area max.
35 mm2 stranded / 25 mm2 flexible
For mounting on
35 mm DIN rail acc. to EN 60715
Enclosure material
thermoplast, grey, UL 94 V-0
Degree of protection
IP 20
Capacity
1 module, DIN 43880
Type of remote signalling contact
changeover contact
Switching capacity AC
250 V/0.5 A
Switching capacity DC
250 V/0.1 A; 125 V/0.2 A; 75 V/0.5 A;
Cross-sectional area remote
signal terminal
max. 1.5 mm2 solid / flexible
Ordering information / type
OVP unit
Module
HUBER+SUHNER
2 units 9079.99.0001
9079.99.0001M
9079.99.0001M
1 unit 9079.99.0001
9079.99.0001M
39
Power Distribution and Overvoltage Protection (OVP) Boxes
•
•
•
•
•
•
•
•
HUBER+SUHNER designs customized solutions dependent on local regulations and operator requirement
Systems for 48 V (DC) power supply
With or without overvoltage protectors and circuit breakers.
Various housing materials and sizes depending on the requirements
For indoor and outdoor applications
Cable entry for multi-wire power cables
Cable exits for power jumpers to each RRH
With pressure compensation elements on request
Configuration example #1: Distribution box without OVP and circuit breakers
Features
• Ruggedized outdoor 48 V power distribution box
for 3 RRH
• Aluminium die cast box
• Ingress protection IP67
• Brackets for mounting on poles, walls and tower
legs
• 1 power entry for cable Ø 11 – 17 mm, minimum
wire cross section 6 x 6 mm2 (AWG 10)
• 3 power outputs for cable Ø 8 – 13 mm, minimum
wire cross section 4 mm2 (AWG 12), 9.5 A (DC)
per line
• Connection terminals for internal wiring
;
558
558
558
558
558
558
Wiring diagram
;
/
/
/
/
;
/
/
/
3(
3(
3(
3RZHU,Q
40
HUBER+SUHNER
Power Distribution and Overvoltage Protection (OVP) Boxes
Configuration example #2: Power distribution box with circuit breakers
Features
• 48 V (DC) power distribution box with output circuit
breakers for 3 RRH
• Box material polycarbonate
• Ingress protection IP65
• 1 power entry for cable Ø 19 – 22 mm, minimum
wire cross section 6 mm2 (AWG 10)
• 3 power outputs for cable Ø 14 – 16 mm, minimum
wire cross section 4 mm2 (AWG 12), 10 A (DC) per
line
• Grounding exit for cable Ø 10 – 12 mm, grounding
wire cross section 16 mm2 (AWG 5)
• 3 circuit breakers 10 A class C (60 V DC)
• Free space to upgrade for 3 additional RRH
)
)
)
&LUFXLW%UHDNHUV
9
3ROH&$
;
558
558
558
558
558
558
Wiring diagram
;
/
/
;
/
/
3(
3(
/
/
3(
3RZHU,Q
HUBER+SUHNER
41
Power Distribution and Overvoltage Protection (OVP) Boxes
Configuration example #3: Box with surge protectors and circuit breakers
Features
• 48 V (DC) power distribution box with type 2,
class II overvoltage protection modules and output
circuit breakers for 3 RRH
• Box material polycarbonate
• 1 power entry for cable Ø 19 – 22 mm, minimum
wire cross section 6 mm2 (AWG 10)
• 3 power outputs for cable Ø 14 – 16 mm, minimum
wire cross section 4 mm2 (AWG 12), 10 A (DC)
per line
• Grounding exit for cable Ø 10 – 12 mm, grounding
wire cross section 16 mm2 (AWG 5)
• 3 circuit breakers 10 A class C (60 V DC)
• 2 type 2, class II overvoltage protection elements
– Voltage protection level Up ≤ 400 V
– Max. discharge current (8/20 µs)
Imax.= 40 kA
– Built in remote signalling contact
558
558
558
558
558
558
Wiring diagram
5HPRWHVLJQDOOLQJ
FRQWDFWV
)
)
)
;
;
/
;
/
/
/
/
/
;
3(
3(
3(
5
2937\SH,,
8F9a
,QN$
,PD[N$
8
5
8
2937\SH,,
8F9a
,QN$
,PD[N$
&LUFXLW%UHDNHUV
9
3ROH&$
3(
3RZHU,Q
42
HUBER+SUHNER
Multi-riser Cable with compact Divider
This installation method uses robust cable divider instead of distribution boxes which makes the solution compact
and space-saving. The genuine plug-and-play cabling system makes this method most cost-effective and installation
friendly. It is the preferred choice of network installers who care about reliable and efficient field deployment without
troubles. HUBER+SUHNER’s MASTERLINE extreme product family is unique in the market and provides the best
value for money. The resulting passive cable infrastructure is future-proof, supports network expansions and saves
installation and follow-up costs.
LISCA RF jumper (page 84)
FTTA extension jumpers (page 48)
Power extension jumpers
(page 51)
MASTERLINE extreme (page 46)
MASTERLINE extreme Power
(page 50)
Overlength box (page 23)
44
HUBER+SUHNER
Application and features
•
•
•
•
Optimum for co-located antennas, e.g. mast-top installation
Preferred method of network installers
Use of ODC jumper cables makes the passive cable infrastructure system and vendor independent
Cable system designed for 20-years life time which enables network evolution for future generations of active
equipment
Benefits
•
•
•
•
•
•
The most cost-effective installation method (CAPEX)
Minimum installation times, genuine plug&play system
Flexible in relation to RRH replacement with ODC jumpers
Scalable for 3 up to 9 RRH, supports planned LTE roll-outs and network expansions
Future-proof as passive cable infrastructure supports all aspects of network evolution
Space saving and low wind load
Issues
• Limited suitability for cell sites with distributed antennas
• Slightly reduced flexibility and scalability in comparison with the box solution
HUBER+SUHNER
45
Fiber Optic MASTERLINE extreme
Features
•
•
•
•
•
•
Pre-assembled plug&play cabling system
Terminated with ODC or with RRH-specific interface
Ruggedized design with robust break-out cables
Outdoor and indoor with high flame resistance
Temperature range –40 °C up to +75 °C
Loose tube cables with up to 24 fibers, rodentprotected and UV resistant
• Fibers and connectors colour coded for easy
channel identification
• Easy and time-saving installation
Specifications
Number of fibers
6
up to 18
Numer of RRHs
3
up to 9
Divider
small
medium
Build-in hole dimension
15.6 –16.4 mm
25.5 – 26-5 mm
Tensile load on individual break-out cables
600 N
Ingress protection with ODC connector
IP68
Maximum break-out lengths
4m
Break-out cable diameter
Ø 5 mm
Glass-armoured loose-tube cable
Jacket material
LSFH
Cable diameter
2 – 24 fibers
8.5 mm
during installation
3000 N
in service
1500 N
short-term
400 N/cm
long-term
200 N/cm
installation
–25°C to 75°C
in service
–40°C to 75°C
IEC 60332-1,
IEC 60332-3-24
passed
Tensile strength
Crush resistance
Temperature range
Flame resistance
divider with thread and mounting groove
seal ring
installed
length
pigtail:
46
shortest length
longest length
HUBER+SUHNER
MASTERLINE extreme
Standard portfolio
•
•
•
•
•
MASTERLINE extreme with 6, 8, and 12 fibers
Side A (RRH) terminated with ODC connectors
Side B (base station) terminated with LC connectors (MASTERLINE classic HT)
Adaptation to any RRH interface with ODC extension jumpers
Colour coded connectors
Colour coding
RRH 1+7
RRH 2+8
RRH 3+9
RRH 4+10
RRH 5+11
RRH 6+12
red
green
blue
yellow
white
black
Ordering information
MASTERLINE extreme with ODC / MASTERLINE classic HT with LC duplex connectors
6 fibers – 3 RRH
Length
Fiber type
8 fibers – 4 RRH
12 fibers – 6 RRH
Item number
20 m
84118386
84118411
84118435
30 m
84118387
84118412
84118436
40 m
84118388
84118413
84118437
50 m
84118389
84118414
84118438
60 m
84118390
84118415
84118439
70 m
84118391
84118416
84118440
84118392
84118417
84118441
80 m
singlemode
90 m
84118393
84118418
84118442
100 m
84118395
84118419
84118443
125 m
84118396
84118420
84118444
150 m
84118397
84118421
84118445
200 m
84118398
84118422
84118446
20 m
84118399
84118423
84118447
30 m
84118400
84118424
84118448
40 m
84118401
84118425
84118449
50 m
84118402
84118426
84118450
60 m
84118403
84118427
84118451
70 m
84118404
84118428
84118452
84118405
84118429
84118453
84118406
84118430
84118454
80 m
90 m
multimode OM2
100 m
84118407
84118431
84118455
125 m
84118408
84118432
84118456
150 m
84118409
84118433
84118457
200 m
84118410
84118434
84118458
HUBER+SUHNER
47
Fiber Optic MASTERLINE
Further MASTERLINE product configurations are available upon request.
MASTERLINE extreme with ODC / MASTERLINE classic HT with MTP connector
MASTERLINE extreme with RRH specific connectors for direct mating
ODC Extension Jumpers
Features
• Ruggedized and robust cable extension - easy and
reliable to install
• ODC extension connector (female) compatible with
ODC plug connector (male)
• Used in combination with MASTERLINE extreme
terminated with ODC connectors
• Extension jumpers available for all types of RRH
• Cable diameter 4.8 mm, 5.5 mm or 7 mm
• Standard lengths of 1, 2 or 5 m, any customized
length available.
• Ingress protection IP68
• Tensile load 800 N
• On request, colour coded jumpers for easy
installation available
48
HUBER+SUHNER
ODC Extension Jumpers
Ordering information
Jumper description
•Extension jumper with
LC duplex and metal divider
Item no.
Singlemode low-bend
Item no.
Multimode
1m
84094368
–
2m
84122229
–
5m
84122230
–
1.5 m
84124948
84096703
3m
84124949
84096917
6m
84124950
84096918
1m
84124951
84124954
2m
84124952
84124955
5m
84124953
84124956
1m
–
84122231
2m
–
84122232
5m
–
84122233
1m
84124959
84087050
2m
84124960
84124957
5m
84124961
84124958
Length
Picture
•Cable Ø 5.5 mm
•Extension jumper with
LC duplex
•Cable Ø 7 mm
•Extension jumper with
LC duplex
•Cable Ø 5.5 mm
•Extension jumper with
LC boot 90 degree
•Cable Ø 7 mm
•Extension jumper with LC
straight degree
•Cable Ø 7 mm
Further extension jumpers for all type of remote radio systems available (e.g. Q-XCO, XCO, R2CT, LC push-pull connector,
industrial LC connector).
MASTERLINE extreme - a preferred solution in
North American and European market
This ruggedized cable systems reduces the installation time and helps
operators to roll out their networks efficiently. Installers are positive
about the real plug&play system which proved to be extremely
robust and hard-wearing in the field.
HUBER+SUHNER has delivered thousands of MASTERLINE extreme
solutions to operators, e.g. Sasktel, and additional network roll-outs are
planned in North America and Europe.
HUBER+SUHNER
49
MASTERLINE extreme Power
Features
•
•
•
•
•
•
•
•
Pre-assembled plug&play power cabling system
Open-end or terminated with power connector
Ruggedized design with robust break-out cables
Heat, moisture and sunlight (UV) resistant
Outdoor and indoor with high flame resistance
Colour coding for easy channel identification
Easy and time-saving installation
Break-out cable available with cross section
2 x 4 mm2 (AWG 12) and 2 x 6 mm2 (AWG 10)
• Main-cable available with cross section 6 x 6 mm2
(AWG 10), 6 x 10 mm2 (AWG 8) and 2 x 16 mm2
(AWG 6)
• Optional with additional power jumpers for higher
installation flexibility
Specifications
Enclosure
aluminium, black anodized
Connector
polyimide, UL94V-0/UV resistant
Contacts
nickel brass, 32 A
Temperature range
–40°C to +75°C
Ingress protection
IP68
Tensile load
1700 N (depended on cable type)
Max. available length
200 m
Packaging
individual cable reels
Cable
European version (under development)
US version
Jacket material
heat, moisture, and sunlight resistant LSFH™ jacket
heat, moisture, and sunlight resistant polyvinyl
chloride (PVC) jacket
Conductor
tinned copper stranded
class B stranded, soft drawn, bare copper
conductors
Braid
tinned copper
tinned copper (85 % coverage)
Ground wires
no
3 symmetrical wires
Bending radius
200 mm
230 mm (AWG 10) / 300mm (AWG 8)
Temperature range
–40°C to +70°C
–40°C to +90°C
Flammability rating
flame resistant
FT4 vertical flame test
Voltage
breakdown 300 VRMS, 60 Hz, 1 minute between
conductors
voltage rating 600V
6 x 6 mm2
14.50 ± 0.50 mm
6 x 10 AWG
20.1 ± 0.50 mm
6 x 10 mm 19.20 ± 0.80 mm
6 x 8 AWG
24.5 ± 1 mm
Cable diameter
2
MASTERLINE extreme Power, connectorized
Please contact HUBER+SUHNER for customized MASTERLINE extreme Power solutions.
50
HUBER+SUHNER
MASTERLINE extreme Power Jumpers
Features
• Power jumper for connection between MASTERLINE
extreme Power and RRH
• Plug & play for direct deployment (no tools
required)
• Open-end or terminated with second RRH power
connector
• Heat moisture and sunlight (UV) resistant
• Outdoor and indoor with high flame resistance
• Easy and time-saving installation
• Break-out cable available with cross section
2 x 4 mm2 (AWG 12) and 2 x 6 mm2 (AWG 10)
Specifications
Connector
polyimide, UL94V-0/UV resistant
Contacts
nickel brass, 32A
Temperature range
–40°C to +75°C
Ingress protection
IP68
Jacket material
LSFH™
PVC
Conductor
tinned copper stranded
bare copper
Braid
tinned copper
tinned copper
Temperature range
–40°C to +70°C
–40°C to +90°C
2 x 4 mm2
9.4 mm
2 x 12 AWG
2 x 6 mm 10.6 mm
–
Cable diameter
2
10.9 mm
Power jumper for MASTERLINE extreme Power
Please contact HUBER+SUHNER for customized MASTERLINE extreme Power solutions.
HUBER+SUHNER
51
Re-use of Corrugated Copper Cables
In recent network upgrades, conventional cell sites using corrugated cables are often converted into remote radio
systems. The installed corrugated cables are decommissioned, cut at both ends and re-used as supply lines for the
RRHs.
The inner and outer conductor of a corrugated cable are used for the power supply. The special Power Smart DC
adapter is fitted at both ends of the currugated cable, guaranteeing secure and reliable contacts. Short jumper
cables are laid on both sides, leading to the base station or to the box on the mast. A thin multi-riser fiber optic cable
is drawn into the inner conductor of a second corrugated cable from "above" (RRH side). The MASTERLINE classic is
pre-terminated with connectors on one side and is inserted into the box, while the cable is spliced on the base station
side. This installation method saves expensive work on the "cable path" and consequently, no structural work is
required for wall and roof ducts, cable conduits do not need to be opened and no new cables need to be laid.
RRH jumper (page 34)
Power jumper (page 51)
FTTA box (page 28)
Power box (page 41)
MASTERLINE classic HT with
3.5 mm cable (page 54)
Seal kit (page 54)
Power Smart DC kit (page 57)
CTB 19" splicing box (page 55)
LC patchcord (page 55)
52
HUBER+SUHNER
Application and features
•
•
•
•
Conversion of conventional cell sites (with corrugated feeders) into RRH systems
Re-use of corrugated feeder cables – no new cable installation required
Optimum for co-located antennas, e.g. mast-top installation
3 corrugated cables do support up to 6 RRHs (2 cables for power supply, 1 cable for fiber optic routing)
Benefits
•
•
•
•
•
•
Significant savings per converted cell site
No expensive installation work on the "cable path" required
Reduced installation times, lower level of investment (CAPEX)
Scalable for 3 up to 6 RRH, suited for planned LTE roll-outs and expansions
Future-proof because the passive cable infrastructure supports all aspects of network evolution
Best flexibility in case of RRH replacement as short jumpers can be easily exchanged
Issues
• Limited suitability for cell sites with distributed antennas
• Power supply per corrugated cable limited to max. 3 RRH
HUBER+SUHNER FIBER
53
Fiber Optic MASTERLINE classic HT for Corrugated Cables
Features
• Special cabling system pulled to inner conductor of
corrugated copper cable
• Compatible with 7/8", 1 1/4" and 1 5/8" cables
• Cable drawn from "above" (RRH side) - tested for
cable runs up to 50m (with repeated bendings)
• System supports up to 6 fibers (3 RRHs)
• MASTERLINE classic HT plugged into FTTA box and
spliced at base station
• Ruggedized design with robust pulling tube
• Easy and time-saving installation
Specifications
General MASTERLINE classic HT specifications
see page 30
Cable type
multifiber loose-tube cable
Cable jacket
PE flame retardant / halogen-free
Cable diameter
3.5 mm
Tensile strength
Crush resistance
Temperature range
during installation
900 N
in service
250 N
short-term
300 N/cm
long-term
100 N/cm
in service
35 mm
installation
–25°C to 50°C
in service
–40°C to 70°C
Contact HUBER+SUHNER to design and order MASTERLINE classic for corrugated feeders
HT
Seal Kit for Corrugated Cables
Features
• Sealing of fiber optic cable entry into corrugated
feeders
• Field mountable kit
• Seal kits for 7/8", 1 1/4" and 1 5/8" cables
• Ingress protection IP67
Ordering information
Description
Quantity
Item no.
Seal kit 7/8"
2 seals
84074074
Seal kit 1 1/4" and 1 5/8"
2 seals
84074075
54
HUBER+SUHNER
19" CTB Cable Termination Box
Features
•
•
•
•
•
Space saving 19" rack installation
Flush or recessed (70 mm) installation
Front plate with mounted LC duplex adapters
Pullout tray for easy access
Interface for MCM splice cassette with bend radius
35 mm throughout
• LC pigtails for splicing included
• Material standard aluminium
Ordering information
Description
CTB 19" fiber frame,
MCM splice cassette,
LC pigtails, LC adapters
Number of fibers Fiber type
Ordering code
6
singlemode
FB1-B88-0306-09-11-H5-AK-20ODK
6
multimode
FB1-B88-0306-50-11-H5-AK-20OMK
12
singlemode
FB1-B88-0612-09-11-H5-AK-20ODK
12
multimode
FB1-B88-0612-50-11-H5-AK-20OMK
LC connector patchcords
Features
• LC patchcord to connect 19" CTB to active
equipment (base station)
• Robust 2 mm cable
• Simplex and duplex patchcords available
• Upon request, colour coded connectors
Ordering information
Description
Number of fibers Fiber type
simplex
LC patchcord with length L [m]
duplex
HUBER+SUHNER FIBER
Ordering code
singlemode
20H01CE0-09-85/85-2-L NN
multimode
20H01CE0-50-85/85-2-L MM
singlemode
20HD8CE0-09-88/88-2-L NN
multimode
20HD8CE0-50-88/88-2-L MM
55
Re-use of Corrugated Copper Cables
Re-use of corrugated cables – HUBER+SUHNER
pioneered first successful roll-out with Vodafone
Germany
An increasing number of traditional base stations using corrugated feeder cables are converted into RRH systems. With the use of
HUBER+SUHNER’s Smart DC Kits and MASTERLINE classic, cell
sites can be upgraded with minimum downtime and with completely
avoiding expensive cable routing. These advantages saved millions of
Euros of installation costs for Vodafone Germany. HUBER+SUHNER
was the preferred partner to upgrade the 3G network. More conversions all over Europe are on their way, especially with the increasing
number of LTE installations.
Additional products
FTTA Fiber-to-the-Antenna box
See page 28
RRH jumpers
See page 34
56
HUBER+SUHNER
Smart DC Kit
Features
• For adaptation of DC power cable to corrugated
copper cable
• Kits for cables sizes 7/8’’, 1 1/4’’ and 1 5/8’’
• Available as stand-alone kit or as adapter pigtail
with 2 x 10 mm2 or 2 x 16mm2 DC cable (solid or
stranded wire)
• DC current rating 40 A
• Lightning current handling 50 kA
• Multibrand corrugated cable compatibility
Benefits
• Saving installation time and costs
• Quick and easy field installation
• Tooling support for both – stripping and easy
coax flaring
Specifications
Product conformity (TÜV approved)
IEC/EN 61984
Corrugated cable compatibility list
see datasheets
DC current rating
40 A1)
DC voltage rating
100 V
Rated impulse voltage
1.5 kV, 1.2/50 µs
Overvoltage category IEC 60664-1
III
Partial lightning current handling
50 kA, 10/350 µs, 3 pulses
IP rating IEC 60529
IP 67
Pollution degree
1
Upper limiting temperature
+ 85 °C
Lower limiting temperature
– 40 °C
Cable retention / cable gland
≥ 70 N, typ. 105 N
Material
Body
brass, nickel plated
Contact holder
brass, nickel plated
Centre contact
CuBe, nickel plated
Cable gland
brass, nickel plated
1) Higher current rating for 1 1/4" Smart DC Kit possible
HUBER+SUHNER FIBER
57
Smart DC Kit
Ordering information
Smart DC kit
H+S type
Item no.
Description
Smart DC kit with solid wire 2 x 10 mm2 cable NYCWY 2 x 10RE/10
7/8"
1 1/4"
1 5/8"
73_Z-50-23-5
84117348
no pigtail
73_Z-50-23-8
84123654
assembled with 5 m DC cable
73_Z-50-23-9
84123656
assembled with 10 m DC cable
73_Z-50-32-5
84122432
no pigtail
73_Z-50-32-8
84123745
assembled with 5 m DC cable
73_Z-50-32-9
84123754
assembled with 10 m DC cable
73_Z-50-42-5
84122550
no pigtail
73_Z-50-42-8
84123742
assembled with 5 m DC cable
73_Z-50-42-9
84123743
assembled with 10 m DC cable
Smart DC kit with solid wire 2 x 16 mm2 cable NYCWY 2 x 16RE/16
7/8"
1 1/4"
1 5/8"
73_Z-50-23-5
84117348
no pigtail
73_Z-50-23-6
84115873
assembled with 5 m DC cable
73_Z-50-23-7
84115875
assembled with 10 m DC cable
73_Z-50-32-5
84122432
no pigtail
73_Z-50-32-6
84122548
assembled with 5 m DC cable
73_Z-50-32-7
84122549
assembled with 10 m DC cable
73_Z-50-42-5
84122550
no pigtail
73_Z-50-42-6
84122553
assembled with 5 m DC cable
73_Z-50-42-7
84122557
assembled with 10 m DC cable
Smart DC kit with stranded wire 2x16mm2 cable N2XC2Y 2 x 16
7/8"
73_Z-50-23-15
84123563
no pigtail
73_Z-50-32-15
84123734
assembled with 5 m DC cable
73_Z-50-42-15
84123746
assembled with 10 m DC cable
74_Z-0-23-18
84074476
trimming tool
74_Z-0-32-14
23010533
jacket stripping
74_Z-0-32-15
84120843
flaring tool
74_Z-0-42-14
23010534
jacket stripping
74_Z-0-42-15
84085074
flaring tool
Trimming and flaring tools for coaxial cable
7/8"
1 1/4"
1 5/8"
58
HUBER+SUHNER
Smart DC Kit
Additional products
PTTA Power-to-the-Antenna box
See page 35
Power distribution box with surge protectors and circuit
breakers
See page 42
Power supply cable
See page 24
HUBER+SUHNER FIBER
59
Hybrid Solutions
Hybrid cables combine glass fibers and copper wires in a single cable and are used to supply RRH directly. At first
glance, hybrid seems to be easy and straight-forward. In fact, hybrid cables are the most complex and cost-intensive
installation method and certain hybrid solutions can even be regarded as an obstable to installation. Nevertheless,
there are installation scenarios and niche-applications for which hybrid cables can be the optimum choice.
In contrast to corrugated feeder or power supply cables, hybrid cables can not be cut to length in the field and
terminated. Cutting hybrid cables to length requires either that the fiber optic connectors are able to be terminated
in the field or that the optical fibers are spliced with pre-terminated connector pigtails. Most RRH interfaces require
harsh environment connectors or ruggedized cable designs which can only be factory produced. Field-termination of
fiber optic connectors is simply a no-go. The other option is fusion splicing of optical fibers. Splicing requires special
skills and equipment but is a realiable process in protected environments, e.g. inside telecom rooms or cabinets. However, at roof-top or mast applications, remote radios are exposed to extreme temperature changes, vibrations due
to wind load and changes in humidity. These extreme conditions can lead to breakage of fusion splices resulting in
drop outs of the radio cells. Fusion splices bear an unpredictable network reliablity risk.
Hybrid
Cut-to-length
in field
Field-termination connector
Factory terminated
(fixed length)

Splicing on mast

Overlength management
Hybrid, corrugated
Hybrid, standard
Factory terminated cables are always delivered with a certain excess length to prevent installation failures because
of cables that are too short. Cable overlength management is necessary and is usually done at the bottom of the
mast or inside the cabinet. While storage of thin and flexible fiber optic excess cable is common practice, overlength
management for thick and bulky hybrid cable can be a real challenge and is a waste of expensive copper cable.
Standard hybrid cables with braided shieldings are relatively flexible and the copper part of the cable can be stripped back avoiding space consuming cable storage. Corrugated hybrid cables are more rigid, provide no flexibility
in terms of overlength management and are comparatively expensive. However, standard grounding and mounting
clamps for corrugated copper cables can be used.
60
HUBER+SUHNER
Application and features
• Niche application – only suited for special installation scenarios
• By far the most complex and expensive installation method
• Disadvantageous combination of two cable technologies which are fundamentally different
– Fiber optic cables are bending radius sensitive, factory terminated, connectorized, and delivered at
pre-defined lengths
– Copper cables can be cut and clamped in the field, need to be shielded and grounded, and are
3 to 5 times thicker than fiber optic cables.
• Fiber optic cables can support distances beyond 1 km while hybrid cables are limited to distances of
about 100 m.
Benefits
• Only one cable needs to be installed.
Disadvantages
•
•
•
•
Hybrid cables are always more expensive than separated fiber optic and power supply cables
Long site installation times and inefficient
Hybrid cable overlength management challenging or impossible for pre-assembled systems
Field termination of hybrid cables is very complex and entails high levels of risk in terms of installation and
reliability
• Corrugated hybrid cables are not compatible with RRH interfaces and required cable diameters.
HUBER+SUHNER
61
MASTERLINE extreme Hybrid
This factory-terminated hybrid cable assembly minimizes the amount of cables running up the mast. A compact
divider splits the multi-fiber / wire cable into individual ruggedized outdoor cables which are linked to the RRHs –
either directly or via special jumpers. The jumpers allow an adaptation to different RRH interfaces and therefore make
the solution independent from the system vendor’s hardware.
MASTERLINE extreme Hybrid is tailored for mobile operators who do not have own tower infrastructure but rent the
majority of their tower cell sites. A common cost model is that the tower owner charges a variable rental fee based
on the amount of cables running up the mast. The hybrid solution minimizes the annually recurring rental fee at the
one-time cost of a more expensive and complex cable infrastructure. However, without having this special rental requirement, a cable infrastructure with separated fiber optic cables and power cables is the better choice.
LISCA RF jumper (page 84)
FTTA jumpers (page 18)
Power jumpers (page 51)
MASTERLINE extreme Hybrid
(page 63)
CTB 19" splicing box (optional)
(page 55)
LC patchcord (optional)
(page 55)
62
HUBER+SUHNER
MASTERLINE extreme Hybrid
Features
• Pre-assembled hybrid cabling system for 3 up to 4
RRHs
• Ruggedized enclosure with robust break-out cables
– eliminates distribution box and excess hardware
• Plug&play for direct deployment (no tools required)
• Power cable connectorized at RRH and open end
at base station
• Fiber optic cable connectorized at both ends
• Ripcord to strip back and cut power cable at base
station (for overlength management)
• Supplied on reels for easy deployment
• Colour coding for easy channel identification
• Outdoor and indoor with high flame resistance
• Optional with additional fiber optic and power
jumpers for higher installation flexibility
Specifications
Temperature range
–40°C to +70°C
Ingress protection
IP68
Enclosure
aluminium, black anodized
Cable head RRH
FO: MASTERLINE extreme with ODC or RRH connector
power: connectorized or open end
Cable head base station
FO: MASTERLINE classicHT with LC duplex connector
power: open end
ripcord for hybrid cable jacket stripping
Power breakout cable
AWG 12
Fiber optic breakout cable
Ø 5 mm (2 fibers), Ø 6 mm (4 fibers)
Packaging
individual cable reels
Hybrid cable
Jacket material
PVC, resistant to sunlight (UV), moisture, and corrosive agents
Installation
suitable for use in ducts, conduits, aerials, exposed runs, cable trays, and direct burial installations
Copper
up to 8 x 8 AWG (4 pairs)
Conductors
bare copper, 8 AWG class C 19 strand
Color code
ICEA S-73-532 E6 (NEMA WC 57), black, white, red, blue, green, orange, yellow, brown
Shielding
copper/mylar foil (100 % coverage)
Drain wires
tinned copper, 16 AWG, 7 strand
Fiber optic
up to 14 fibers (singlemode or multimode)
Cable diameter
25 mm (8 x 8 AWG)
Cable weight
1.15 kg/m
Pulling tension
2.8 kN
Minimum bending radius
30 cm
Voltage rating
600 V
Nom. DC Resistance
2.1 Ω/km @ 20°C
Flammability rating
UL 1685 (UL 1581) vertical tray flame test (70,000 BTU/hr)
HUBER+SUHNER
63
MASTERLINE extreme Hybrid
MASTERLINE extreme Hybrid for 3 RRHs
Please contact HUBER+SUHNER to design customized MASTERLINE extreme Hybrid solution.
Additional products
ODC extension jumper
See page 48
Power extension jumper
See page 51
Excess length box
See page 23
64
HUBER+SUHNER
Hybrid Roof Top Application
In urban areas and highly populated areas, antennas are often mounted on rooftops of tall buildings. In the case of
traditional corrugated feeder systems, large and heavy base stations need to be lifted by crane to the rooftops and
require high-power provisioning. Remote radio systems allow for longer distances between antennas and the base
station which can therefore be located in special telecoms room inside the building.
On the rooftop, cables need be laid from a distribution box (or base station) to the individual RRHs close to the antennas. In this scenario, factory-terminated hybrid cable can be the optimum choice. Instead of running separated signal and power supply cables in special conduits, ruggedized hybrid cables (e.g. reinforced against being stepped
on) are routed. Additionally, the required cable runs are usually well known and the hybrid cable can be terminated
at the exact required length at the factory – overlength management is not an issue in this case.
Hybrid cable assembly (page 66)
Hybrid box
MASTERLINE classicHT (page 30)
Power feeder (page 36)
HUBER+SUHNER
65
Hybrid Assemblies
Features
• Pre-assembled hybrid cable at pre-defined length
• Integrated power cable with braided shielding for
highest flexibility
• Ruggedized cable design and splitter for
• Power cable connectorized at RRH or open end at
both sides
• Fiber optic cable connectorized at both ends
• Plug-and-play installation – no field termination /
wrapping / preparation necessary
• Available in all dimensions and fiber types
• Outdoor and indoor with high flame resistance
Specifications
Temperature range
–40°C to +75°C
Ingress protection
IP68
Cable head RRH
FO: terminated with ODC or RRH specific connector
power: connectorized or open end
Cable head base station
FO: terminated with LC duplex connector or ODC
power: open end
Cable divider
glued heat shrink
Power breakout cable
shielded
Fiber optic breakout cable
Ø 5.5 mm (2 or 4 fibers)
Hybrid cable
Jacket material
LSFH™
Copper
2 x 4 mm2, 2 x 6 mm2 or 2 x 10 mm2
Cable diameter
15 – 20 mm (depending on cable construction)
Pulling tension
800 N (fiber optic breakout cable)
Order information
Hybrid cable assembly terminated with ODC and power connector.
Please contact HUBER+SUHNER to design customized Hybrid solutions.
66
HUBER+SUHNER
HUBER+SUHNER
67
Fiber Optic Interfaces for Remote Radio Heads
HUBER+SUHNER is the leading supplier of harsh environment fiber optic interfaces for remote radio heads. RRH
are installed in many different types of environments like coastal areas, urban buildings or rural tower sites and extreme temperatures, vibration, salt mist, corrosive gases and humidity are all typical challenges. Therefore robustness
and reliablity are crucial for the design of RRH interfaces. Additionally, the interface needs to be safe to install and
must not cause for any installation errors – this is essential to compensate for unskilled installers. Damage to fiber
optic interfaces is the number one cause of defects during RRH installation. Innovation and field-experience enables
HUBER+SUHNER to design leading RRH interfaces like the ODC.
68
HUBER+SUHNER
Content
HUBER+SUHNER
Q-XCO
quick-lock ruggedized SFP connector
70
ODC ® -2
outdoor connector plug / socket 74
Q-ODC ®
outdoor connector plug / socket 76
ODC ® -4
outdoor connector plug / socket
78
XCO
quick-lock ruggedized SFP connector
80
69
Q-XCO – Quick-lock ruggedized SFP Connector
Features
• Quick-lock mating connector for remote radio head
and industrial applications
• Ruggedized outdoor design with 2 x LC interface
• Plugs directly into SFP module, compatible with all
standard SFP modules
• Full compensation of positioning tolerances and SFP
module tolerances
• Bayonet, blind-mating mechanism and highest
installation safety
• Full protection of optical interface during installation
• Access and exchange of SFP module possible
• RoHs compliant
Mating mechanism
1-step blind mating
bayonet
mating references
visual and latch
z-axis
± 2.25 mm
x,y-axis
± 0.6 mm (± 0.8 mm depending on SFP module)
Latching of LC connector
use of LC HQ technology
automating latching and unlatching
Mating durability
IEC 61300-2-2
100 cycles
Mating
Compensation of positioning
tolerances of SFP module
Force on SFP module
no force in mated state
Specifications
Technology
Housing material
LC full ceramic ferrules
connector
high-performance plastic
socket
die-casting with zinc plating
Material flammability rating
UL94-V0
IEC 61300-2-4
≤ 400 N tensile load
IEC 61300-2-42
≤ 30 N static side load
IEC 61300-2-5
180° cable torsion, passed
operation, IEC 61300-2-22
–40°C to +85°C
installation
–40°C to +55°C
Ingress protection
IEC 60529-20
IP67 (mated or with dust cap)
Salt mist
IEC 61300-2-26, MIL-STD-202G Method 101E
192 h
Vibration
IEC 61300-2-1, MIL-STD-202G, Method 204G
passed 10 Hz – 500 Hz / 10 g
Shock
IEC 61300-3-3, MIL-STD-202G, Method 213B
passed 50 g
UV resistance
ISO 4982-2
passed 2000 h @ 2000 MJ/m2
Mechanical performance
Thermal performance
Optical performance
Insertion loss
Return loss
70
singlemode
typ. ≤ 0.20 dB
97% ≤ 0.45 dB
multimode
typ. ≤ 0.20 dB
97% ≤ 0.50 dB
singlemode
≥ 50 dB
HUBER+SUHNER
Q-XCO – Quick-lock ruggedized SFP Connector
Q-XCO plug
Q-XCO flange small
hole pattern
Q-XCO flange large with asymmetric build-in dimension
Description
Picture
XA (for assembly code)
Q-XCO connector
Item no. 84108683
Q-XCO flange small
Item no. 84108684
Q-XCO flange large
HUBER+SUHNER
Dust cap
71
Q-XCO – Quick-lock ruggedized SFP Connector
Installation safety for LTE and microwave links
Q-XCO is the most installation safe fiber optic interface on the market. The
connector is designed for harsh outdoor applications and for installation
in challenging environments like high up on radio masts under any atmospheric condition. Its "one-hand" blind mating performance in combination
with full SFP tolerance compensation makes this connector the best in its
class. For that reason, leading system vendors have chosen Q-XCO as the
fiber optic interface for LTE remote radios and for state-of-the-art microwave
backhaul systems – simply to have better connections.
Tolerance compensation
± 0.6 mm
± 2.25 mm
The connector compensates for all
tolerances of SFP modules and for
mounting tolerances
Exchange of SFP module
Release and pull SFP module
Mating sequence
Rotate to find correct keying position
72
Slide connector into flange and
rotate 155° until snap-in position
Connector mated with visual reference
for correct installation
HUBER+SUHNER
Q-XCO – Quick-lock ruggedized SFP Connector
SFP cage positioning specification
Exclusion zone for connector mating
HUBER+SUHNER
73
ODC® -2 outdoor Connector Plug / Socket
Features
•
•
•
•
•
•
•
•
•
•
•
•
2 fibers, singlemode or multimode
Compact design with 2 x 1.25 mm ferrules
Built-in socket with square or hexagonal flange
Extension connector for cable chaining
Screwed locking mechanism
Easy and safe installation
Waterproof, dust proof and corrosion resistant
Waterproof protection caps
EMI protected
RoHs compliant
Full compatibility with previous version
Fulfills performance standard IEC 61753-1 Cat. E
Specifications
Technology
full ceramic ferrule and sleeve
Housing material
nickel-plated brass
ODC plug
≤ 800 N tensile load
≤ 30 N static side load
ODC socket
≤ 30 N tensile load
Installation torque force
min. 1 Nm
max. 2 Nm
Operating temperature1)
IEC 61300-2-22
–40°C up to + 85 °C
Mechanical performance
1000 cycles2)
Mating durability
1)
Ingress protection (mated)
IEC 60529
IP68
Salt mist
IEC 61300-2-26
30 days passed
Vibration
IEC 61300-2-1
passed 10 – 500 Hz / 10g
Shock
IEC 61300-2-9
passed 100 g
depending on cable type
2)
with repeated cleaning
Optical performance
Insertion loss
IEC 61300-3-34
singlemode
typ. ≤ 0.20 dB
97% ≤ 0.45 dB
multimode
typ. ≤ 0.20 dB
97% ≤ 0.50 dB
Return loss
singlemode
≥ 50 dB
Standard type A1, A4: ODC-2 plug
Standard type E1, E3: ODC-2 extension
74
HUBER+SUHNER
ODC® -2 outdoor Connector Plug / Socket
Overview of ODC-2 connector types
Type
Connector
A1
Dust cap
screwed cap with chain
ODC-2 plug
screwed cap with pulling
feature
A4
E1
screwed cap
ODC-2 extension
(socket type)
E3
screwed cap with chain
C1
screwed cap
ODC-2 socket,
square small
C3
screwed cap with chain
ODC – Worldwide the most often installed remote radio interface
We believe there is no country in the world in which ODC assemblies have not been installed yet. There is no
other RRH interface which is used more often and which was chosen by more system vendors. The success
comes from the fact that ODC is an extremely robust outdoor connector which withstands all installation
hazards – and most important – does not permit handling errors. ODC makes mobile networks more reliable
and guarantees 100% performance.
HUBER+SUHNER
75
Q-ODC® outdoor Connector Plug / Socket
Features
•
•
•
•
•
•
•
•
•
•
•
2 fibers, singlemode or multimode
Compact design with 2 x 1.25 mm ferrules
Built-in socket with square flange
Extension connector for cable chaining
Robust push-pull coupling mechanism – two clearly
defined mating states
Highest outdoor installation safety
Waterproof, dust proof and corrosion resistant
Waterproof protection caps available
EMI protected
RoHs compliant
Fulfills performance standard IEC 61753-1 Cat. E
Specifications
Technology
full ceramic ferrule and sleeve
Housing material
nickel-plated brass
Mating mechanism
push-pull with two clearly defined states
Mechanical performance
Operating
1)
temperature1)
Q-ODC plug
≤ 450 N tensile load
≤ 30 N static side load
Q-ODC socket
≤ 30 N tensile load
IEC 61300-2-22
–40°C up to + 85 °C
Mating durability
IEC 61300-2-2
200 cycles2)
Ingress protection (mated)
IEC 60529
IP67
Salt mist
IEC 61300-2-26
30 days passed
Vibration
IEC 61300-2-1
IEC 61373
passed 10 Hz – 500 Hz / 10 g
passed category 1A/B, 2, 3
Shock
IEC 61300-2-9
IEC 61373
passed 50 g
passed category 1, 2
depending on cable type
2)
with repeated cleaning
Optical performance
Insertion loss / IEC 61300-3-34
Return loss
singlemode
typ. ≤ 0.20 dB
97% ≤ 0.45 dB
multimode
typ. ≤ 0.20 dB
97% ≤ 0.50 dB
singlemode
≥ 50 dB
Mating sequence
Push plug slightly into
connector socket
76
Rotate to find keying
position
Unmated - push connector
to mate
Mated – connector snaps in
and is fully strain relieved
Pull coupling ring to unmate
HUBER+SUHNER
Q-ODC® outdoor Connector Plug / Socket
Overview of Q-ODC connector types
Type
Connector
Dust cap
QA
push-on
IP54
snap-on
IP67
QB
snap-on with chain
IP67
QE
push-on
IP54
snap-on
IP67
QG
snap-on with chain
IP67
QS
push-on
IP54
snap-on
IP67
snap-on with chain
IP67
QC
QF
QT
QU
Q-ODC plug
Q-ODC extension
Q-ODC socket square
Q-ODC – Push-pull connector for modular cell site
installations
Q-ODC is used by a growing number of operators who build a modular
and flexible cell site cable infrastructure. The push-pull connectors allows
for quick and reliable cable connections, e.g. for top-mast boxes or
jumpers. Additionally, the interface is designed that it is either mated or
unmated – nothing in between. This makes each installation of cell site
infrastructure safe.
HUBER+SUHNER
77
ODC® -4 outdoor Connector Plug / Socket
Features
•
•
•
•
•
•
•
•
•
•
•
•
4 fibers, singlemode or multimode
Compact design with 4 x 1.25 mm ferrules
Built-in socket with square or hexagonal flange
Extension connector for cable chaining
Screwed locking mechanism
Easy and safe installation
Waterproof, dust proof and corrosion resistant
Waterproof protection caps
EMI protected
RoHs compliant
Full compatibility with previous version
Fulfills performance standard IEC 61753-1 Cat. E
Specifications
Technology
full ceramic ferrule and sleeve
Housing material
nickel-plated brass
ODC-4 plug
≤ 800 N tensile load
≤ 30 N static side load
ODC-4 socket
≤ 30 N tensile load
Installation torque force
min. 1 Nm
max. 2 Nm
Operating temperature1)
IEC 61300-2-22
–40°C up to + 85 °C
Mechanical performance
1000 cycles2)
Mating durability
Ingress protection (mated)
1)
IEC 60529
IP68
Salt mist
IEC 61300-2-26
30 days passed
Vibration
IEC 61300-2-1
passed 10 – 500 Hz / 10g
Shock
IEC 61300-2-9
passed 100 g
depending on cable type
2)
with repeated cleaning
Optical performance
Insertion loss
IEC 61300-3-34
singlemode
typ. ≤ 0.20 dB
97% ≤ 0.45 dB
multimode
typ. ≤ 0.20 dB
97% ≤ 0.50 dB
Return loss
singlemode
≥ 50 dB
Type J2, J3: ODC-4 plug
Type E4, E6: ODC-4 extension
78
HUBER+SUHNER
ODC® -4 outdoor Connector Plug / Socket
Standard type K2, K3: ODC-4 socket – hexagonal
hole pattern
Standard type K6, K7: ODC-4 socket – square small
hole pattern
Overview of ODC-4 connector types
Type
Connector
Dust cap
screwed cap with pulling
feature
J2
ODC-4 plug
J3
screwed cap with chain
E4
screwed cap
ODC-4 extension
(socket type)
E6
screwed cap with chain
K2
screwed cap
ODC-4 socket,
hexagonal
K3
screwed cap with chain
K6
screwed cap
ODC-4 socket,
square small
K7
HUBER+SUHNER
screwed cap with chain
79
XCO- ruggedized exchangeable SFP Connector
Features
• 2 fibers, singlemode or multimode
• Standard LC duplex interface
• Ruggedized outdoor connector for fiber-to-the-antenna
and industrial applications
• Exchange and service of SFP module possible
• Easy manual installation – no tool required
• High installation safety due to reliable snap-in strain relief
system (patent pending)
• Waterproof protection cap with pulling eye
• EMI protected
• RoHs compliant
Specifications
Technology
LC with full ceramic ferrules
Housing material
nickel-plated brass
Mating mechanism
snap-in strain relief system
Mechanical performance
≤ 500 N tensile load
≤ 30 N static side load
Operating temperature1)
1)
–40 °C up to +85 °C
Mating durability
IEC 61300-2-2
500 cycles
Ingress protection (mated)
IEC 60529
IP67
Salt mist
IEC 61300-2-26
30 days passed
Vibration
IEC 61300-2-1
passed 10 Hz – 500 Hz / 10 g
Shock
IEC 61300-2-9
passed 50 g
singlemode
typ. ≤ 0.20 dB
97% ≤ 0.45 dB
multimode
typ. ≤ 0.20 dB
97% ≤ 0.50 dB
singlemode
≥ 50 dB
depending on cable type
Optical performance
Insertion loss
Return loss
Mating sequence
Remove protection cap and slide
back connector housing
80
Snap connector into flange – full
strain relief
Remove LC dust caps and plug LC
duplex connectors into SFP module
Screw-on housing to seal connector
HUBER+SUHNER
XCO- ruggedized exchangeable SFP Connector
Type X1: XCO connector plug
Type: XCO build-in flange
hole pattern
Description
Connector
Dust cap
X1
XCO connector
IP67
Item number
84074439
XCO build-in flange
IP67
Positioning dimensions of SFP module
Front face of housing
Top view
PCB
Cage
Transceiver
Lateral mounting tolerance between
SFP module and XCO flange = ± 0.5 mm
recommended 0.2
HUBER+SUHNER
81
Conventional Cell Site Solutions
Content
Contents
Remote radio installation solutions
Standard solution with discrete cables
16
Multi-riser cable with distribution box
26
Multi-riser cable with compact divider
44
Re-use of corrugated copper cables
52
Hybrid solutions
60
Fiber optic interfaces for remote radio heads
68
Conventional cell site solutions
HUBER+SUHNER
12
82
RF jumpers LISCA
84
SUCOFEED corrugated cables
90
QUICK-FIT coaxial connectors
102
POLYCON lightweight connector
110
Lightning protectors
116
Accessories for conventional cell sites
128
Power splitters
138
Radio frequency antennas and
microwave modules
146
83
RF Jumpers - LISCA
LISCA products are designed to meet customer specifications,
delivery requirements and budgets.
LISCA – Low Loss and Low Intermodulation Soldered
Corrugated Cable Assembly.
84
HUBER+SUHNER
Application
This product line is designed to be used:
• As jumper cables for indoor and outdoor applications
• As internal connections for mobile phone base stations
• In antenna links
• As test leads for low intermodulation test equipment
• In general radio transceivers with requirements for low reflection (VSWR),
low attenuation and low intermodulation products
Features
•
•
•
•
•
•
Excellent RF performance
High RF shielding efficiency
Low attenuation
Moisture protection IP68
High flexibility and small bending radius
Low, stable intermodulation products
Benefits
•
•
•
•
•
RoHS compliant (2002/95/EC)
Wide variety of corrugated cable and connector types
Standard products as well as customized assemblies with special
Lengths and markings according to customer specifications
High volume capacity thanks to standard assembly processing at all main
HUBER+SUHNER production sites worldwide
HUBER+SUHNER
85
RF Jumpers – LISCA
Description
LISCA cable assemblies are specially developed for applications where low VSWR and low attenuation combined
with low intermodulaiton products are required. The excellent performance is achieved by utilizing corrugated cables
with low intermodulation connectors and a controlled assembly process with HUBER+SUHNER solder technology.
These products are factory-made cable assemblies and can only be ordered in predetermined lengths. A
hot-polyamide moulding between connector and cable jacket guarantees highest stability and tightness.
Standard LISCA assemblies
These assemblies are produced under stringent quality
manufacturing standards in order to achieve consistent
high performance. All standard products are based on
SUCOFEED cables with black PE jacket material. The
assemblies are 100% tested for attenuation and return
loss according to the technical data. These LISCA products are factory-made cable assemblies and can only
be ordered in predetermined lengths.
Customized LISCA assemblies
HUBER+SUHNER’s strengths also include the production of products according to customer specifications.
This product line offers additional possibilities for demanding customer wishes based on the LISCA standard
requirements.
Additional features:
• Improved return loss values
• Example: better –28 dB at 2.2 GHz with straight N
or DIN 7/16 connectors
• 100% factory tested products for intermodulation
• Example: max. –155 dBc at 1.8 GHz with
2 x 20 W carriers
• Factory tested products on phase length/tolerance
and delay time
• Specified for frequencies up to 6 GHz
• Customized marking, labelling and product
packaging
• Special connector designs
• Products with lengths up to 150 m
86
HUBER+SUHNER
RF Jumpers – LISCA
Assembly performance code
Performance code
LIS...-51
LIS...-52
LIS…-81
LIS…-01
Description
Standard
LTE*
Standard USA
Test leads
Customer specific
Impedance
50 Ω
50 Ω
50 Ω
50 Ω
50 Ω
1)
LIS...-71
Frequency (max. operating)
6 GHz
6 GHz
6 GHz
6 GHz
6 GHz
6 GHz
Length of assemblies
≤ 10 m
≤5m
≤ 12 m
≤5m
≤5m
≤ 120 m
≥ 28 dB
≥ 26 dB
–
–
–
≥ 28 dB
≥ 26 dB
≥ 23 dB
–
–
≥ 28 dB
≥ 26 dB
≥ 21 dB
–
–
≥ 28 dB
≥ 26 dB
–
≥ 22 dB
–
≥ 24 dB
≥ 24 dB
–
–
–
open
–162 dBc (typical)
–150 dBc
–162 dBc (typical)
–160 dBc
–165 dBc
QN: –155 dBc
open
DC ..1.0 GHz
>1.0 .. 2.2 GHz
>2.2 .. 2.7 GHz
>2.2 .. 4.0 GHz
>4.0 .. 6.0 GHz
Return loss
Intermodulation IM3 (2 x 20 W)
RF power
see cable specification
Attenuation
see cable specification
LTE = Long Term Evolution
1)
special marking on cable
Order number for standard LISCA
Example:
LIS - C9F - 11 716 -16 716- 02000 - 51
Product name
SUCOFEED_1/4_HF
C5
SUCOFEED_3/8_HF
C7
SUCOFEED_1/2_HF
C9
SUCOFEED_1/2
Flame retardant: F
Cable type
C12
PE: no indication
Straight male
11
Right angle male
16
Straight female
21
Pattern of connector
716
Connector interface
DIN 7/16
N
Pattern of connector
1
2
1
2
N
QN
QN
Assembly length in mm
Jumper performance code
example: 51
Technical performance
Assembly length: tolerance +/– 1%
Plug to plug
HUBER+SUHNER
Plug to jack
Plug to right angle plug
87
RF Jumpers – LISCA
LISCA connector pattern
Description
Series DIN 7/16
Series N
Series QN
cable: C5, C7, C9, C12
cable: C5, C7, C9, C12
cable: C5, C7, C9, C12
cable: C5, C7, C9, C12
cable: C5, C7, C9, C12
cable: C5, C7, C9, C12
cable: C5, C7, C9, C12
cable: C5, C7, C9, C12
cable: C5, C7, C9
cable: C5, C7
cable: C5, C7
cable: C7
Straight male
(Pattern code: 11)
Right angle male
(Pattern code: 16)
Straight female
(Pattern code: 21)
Straight bulkhead female
(Pattern code: 24)
Right angle bulkhead female
(Pattern code: 29)
Straight bulkhead female
(Pattern code: 25)
cable: C5, C7
88
HUBER+SUHNER
HUBER+SUHNER
89
SUCOFEED – Corrugated Cables
HUBER+SUHNER SUCOFEED product range of foam corrugated coaxial cables with suitable stripping
tools and connectors has excellent electrical, mechanical and climatic properties for indoor as well as for
outdoor installations.
The cables guarantee optimal shielding, low attenuation, low VSWR, excellent intermodulation performance and flexibility for handling and installation on sites.
90
HUBER+SUHNER
Application
• Antenna links and internal connection of cellular base station
• Jumper cables and feeder lines
Features
•
•
•
•
•
Low attenuation design available
High power capability
High shielding effectiveness
UV-resistant
Guaranteed performance up to 3 GHz
Benefits
• In copper and aluminum
• Long history and experience
• Designed for:
– Harsh environments in polar regions
– Extreme heat in the desert
– High humidity in the rain forest
HUBER+SUHNER
91
SUCOFEED – Corrugated Cables
1/4" high-flex
Order/
type no.
Dimension
SUCOFEED_1/4_HF
SUCOFEED_1/4_HF_FR SUCOFEED_1/4_HF_FR_UL
1/4" high-flex
1/4" high-flex
1/4" high-flex
Cable group
M5
M5
M5
Cable design
Jacket version
standard
flame retardant
flame retardant / UL-listed
Inner conductor
(Ø in mm)
Dielectric
(Ø in mm)
Outer conductor
(Ø in mm)
Jacket
(Ø in mm)
1.90
4.60
4.40
6.40
7.60
7.95
Electrical data
Typ. operating frequency
(GHz)
≤18
Impedance
(W)
Capacitance
(pF/m)
79.7
80
Relative signal propagation
(%)
83.5
83
Signal delay
(ns/m)
4.00
Max. operating voltage
(kVrms)
0.6
Typ. attenuation @ 1 GHz
(dB/100m)
19.54
19.56
Typ. attenuation @ 2 GHz
(dB/100m)
28.45
28.53
Typ. attenuation @ 2.2 GHz
(dB/100m)
29.98
30.08
Typ. attenuation @ 2.5 GHz
(dB/100m)
32.17
32.30
Typ. attenuation @ 3.0 GHz
(dB/100m)
35.60
35.77
Max. power @ 1 GHz (40°C)
(kW)
≤0.290
Max. power @ 2 GHz (40°C)
(kW)
≤0.205
Max. power @ 2.2 GHz (40°C) (kW)
≤0.196
Max. power @ 2.5 GHz (40°C) (kW)
≤0.183
Max. power @ 3.0 GHz (40°C) (kW)
≤0.167
50 ± 1
General data
Temp. range operating
(°C)
Temp. range installation
(°C)
Typ. weight
(kg/100m)
Min. bending radius
(mm)
–55 / +85
–40 / +85
–25 / +60
7.5
8.7
25
For detailed data sheets please go to www.hubersuhner.com and then search for type “SUCOFEED”.
92
HUBER+SUHNER
SUCOFEED – Corrugated Cables
3/8" high-flex
Order/
type no.
Dimension
SUCOFEED_3/8_HF
SUCOFEED_3/8_HF_FR SUCOFEED_3/8_HF_FR_UL
3/8" high-flex
3/8" high-flex
3/8" high-flex
Cable group
M7
M7
M7
Cable design
Jacket version
standard
flame retardant
flame retardant / UL-listed
Inner conductor
(Ø in mm)
Dielectric
(Ø in mm)
Outer conductor
(Ø in mm)
Jacket
(Ø in mm)
2.80
7.00
6.90
9.50
10.80
11.15
Electrical data
Typ. operating frequency
(GHz)
Impedance
(W)
Capacitance
(pF/m)
Relative signal propagation
(%)
≤12
50 ± 1
79.5
80
83
Signal delay
(ns/m)
4.00
Max. operating voltage
(kVrms)
0.9
Typ. attenuation @ 1 GHz
(dB/100m)
13.33
Typ. attenuation @ 2 GHz
(dB/100m)
19.43
Typ. attenuation @ 2.2 GHz
(dB/100m)
20.48
Typ. attenuation @ 2.5 GHz
(dB/100m)
21.99
Typ. attenuation @ 3.0 GHz
(dB/100m)
24.34
Max. power @ 1 GHz (40°C)
(kW)
≤0.540
Max. power @ 2 GHz (40°C)
(kW)
≤0.382
Max. power @ 2.2 GHz (40°C) (kW)
≤0.364
Max. power @ 2.5 GHz (40°C) (kW)
≤0.342
Max. power @ 3.0 GHz (40°C) (kW)
≤0.312
General data
Temp. range operating
(°C)
Temp. range installation
(°C)
Typ. weight
(kg/100m)
Min. bending radius
(mm)
HUBER+SUHNER
–55 / +85
–40 / +85
–25 / +60
12.2
13.2
14.2
25
93
SUCOFEED – Corrugated Cables
1/2" high-flex
Order/
type no.
Dimension
SUCOFEED_1/2_HF
SUCOFEED_1/2_HF_FR SUCOFEED_1/2_HF_FR_UL
1/2" high-flex
1/2" high-flex
1/2" high-flex
Cable group
M9
M9
M9
Cable design
Jacket version
standard
flame retardant
flame retardant / UL-listed
Inner conductor
(Ø in mm)
Dielectric
(Ø in mm)
Outer conductor
(Ø in mm)
12.20
12.10
Jacket
(Ø in mm)
13.40
13.65
3.60
9.0
Electrical data
Typ. operating frequency
(GHz)
Impedance
(W)
Capacitance
(pF/m)
Relative signal propagation
(%)
≤10
50 ± 1
80.3
78.5
81
85
Signal delay
(ns/m)
Max. operating voltage
(kVrms)
4.00
3.90
Typ. attenuation @ 1 GHz
(dB/100m)
11.77
10.67
Typ. attenuation @ 2 GHz
(dB/100m)
17.48
15.69
Typ. attenuation @ 2.2 GHz
(dB/100m)
18.48
16.56
Typ. attenuation @ 2.5 GHz
(dB/100m)
19.92
17.81
Typ. attenuation @ 3.0 GHz
(dB/100m)
22.19
19.78
Max. power @ 1 GHz (40°C)
(kW)
≤0.83
≤0.780
Max. power @ 2 GHz (40°C)
(kW)
≤0.587
≤0.552
Max. power @ 2.2 GHz (40°C) (kW)
≤0.56
≤0.526
Max. power @ 2.5 GHz (40°C) (kW)
≤0.525
≤0.499
Max. power @ 3.0 GHz (40°C) (kW)
≤0.479
≤0.450
1.27
General data
Temp. range operating
(°C)
–55 / +85
–40 / +85
Temp. range installation
(°C)
Typ. weight
(kg/100m)
20
Min. bending radius
(mm)
25
–25 / +60
For detailed data sheets please go to www.hubersuhner.com and then search for “SUCOFEED”.
94
HUBER+SUHNER
SUCOFEED – Corrugated Cables
1/2"
Order/
type no.
Dimension
SUCOFEED_1/2
SUCOFEED_1/2_FR
SUCOFEED_1/2_FR_UL
1/2"
1/2"
1/2"
Cable group
M12
M12
M12
Cable design
Jacket version
standard
flame retardant
flame retardant / UL-listed
Inner conductor
(Ø in mm)
4.80
Dielectric
(Ø in mm)
12.10
11.90
Outer conductor
(Ø in mm)
13.80
13.70
Jacket
(Ø in mm)
15.90
16.00
Electrical data
Typ. operating frequency
(GHz)
≤8
Impedance
(W)
Capacitance
(pF/m)
Relative signal propagation
(%)
Signal delay
(ns/m)
3.80
Max. operating voltage
(kVrms)
1.60
Typ. attenuation @ 1 GHz
(dB/100m)
7.29
Typ. attenuation @ 2 GHz
(dB/100m)
10.62
Typ. attenuation @ 2.2 GHz
(dB/100m)
11.20
Typ. attenuation @ 2.5 GHz
(dB/100m)
12.02
Typ. attenuation @ 3.0 GHz
(dB/100m)
13.31
Max. power @ 1 GHz (40°C)
(kW)
≤1.040
Max. power @ 2 GHz (40°C)
(kW)
≤0.735
Max. power @ 2.2 GHz (40°C) (kW)
≤0.701
Max. power @ 2.5 GHz (40°C) (kW)
≤0.658
Max. power @ 3.0 GHz (40°C) (kW)
≤0.600
50 ± 1
75.9
88
General data
Temp. range operating
(°C)
Temp. range installation
(°C)
Typ. weight
(kg/100m)
Min. bending radius
(mm)
HUBER+SUHNER
–55 / +85
–40 / +85
–25 / +60
25.0
27.6
25.8
70
95
SUCOFEED – Corrugated Cables
7/8" high-flex and low attenuation
Order/
type no.
Dimension
SUCOFEED_7/8_HF
SUCOFEED_7/8
7/8" high-flex
7/8"
Cable group
M24
M23
Cable design
Jacket version
standard
standard
Inner conductor
(Ø in mm)
9.40
9.00
Dielectric
(Ø in mm)
22.40
22.30
Outer conductor
(Ø in mm)
25.00
24.80
Jacket
(Ø in mm)
27.50
27.60
Typ. operating frequency
(GHz)
≤4.9
≤5
Impedance
(W)
50 ± 1
50 ± 1
Capacitance
(pF/m)
75.4
75.8
Relative signal propagation
(%)
85
88
Electrical data
Signal delay
(ns/m)
3.90
3.80
Max. operating voltage
(kVrms)
3.00
2.91
Typ. attenuation @ 1 GHz
(dB/100m)
4.25
4.11
Typ. attenuation @ 2 GHz
(dB/100m)
6.42
6.11
Typ. attenuation @ 2.2 GHz
(dB/100m)
6.81
6.46
Typ. attenuation @ 2.5 GHz
(dB/100m)
7.37
6.96
Typ. attenuation @ 3.0 GHz
(dB/100m)
8.26
7.76
Max. power @ 1 GHz (40°C)
(kW)
≤1.940
≤2.190
Max. power @ 2 GHz (40°C)
(kW)
≤1.372
≤1.549
Max. power @ 2.2 GHz (40°C) (kW)
≤1.308
≤1.476
Max. power @ 2.5 GHz (40°C) (kW)
≤1.227
≤1.385
Max. power @ 3.0 GHz (40°C) (kW)
≤1.120
≤1.264
General data
Temp. range operating
(°C)
–55 / +85
Temp. range installation
(°C)
–25 / +60
Typ. weight
(kg/100m)
Min. bending radius
(mm)
48.0
53
90
120
For detailed data sheets please go to www.hubersuhner.com and then search for “SUCOFEED”.
96
HUBER+SUHNER
SUCOFEED – Corrugated Cables
7/8"
Order/
type no.
Dimension
SUCOFEED_7/8_FR
SUCOFEED_7/8_LA
SUCOFEED_7/8_LA_FR
7/8"
7/8" low attenuation
7/8" low attenuation
Cable group
M23
M25
M25
Cable design
Jacket version
flame retardant
standard
flame retardant
Inner conductor
(Ø in mm)
9.00
Dielectric
(Ø in mm)
22.30
22.70
Outer conductor
(Ø in mm)
24.80
25.40
Jacket
(Ø in mm)
27.60
27.90
≤5
≤5.0
50 ± 1
50 ± 1
75.8
73.8
88
90.3
9.50
Electrical data
Typ. operating frequency
(GHz)
Impedance
(W)
Capacitance
(pF/m)
Relative signal propagation
(%)
Signal delay
(ns/m)
3.80
3.70
Max. operating voltage
(kVrms)
2.91
3.00
Typ. attenuation @ 1 GHz
(dB/100m)
4.11
3.76
Typ. attenuation @ 2 GHz
(dB/100m)
6.11
5.53
Typ. attenuation @ 2.2 GHz
(dB/100m)
6.46
5.83
Typ. attenuation @ 2.5 GHz
(dB/100m)
6.96
6.28
Typ. attenuation @ 3.0 GHz
(dB/100m)
7.76
6.97
Max. power @ 1 GHz (40°C)
(kW)
≤2.190
≤2.440
Max. power @ 2 GHz (40°C)
(kW)
≤1.549
≤1.725
Max. power @ 2.2 GHz (40°C) (kW)
≤1.476
≤1.645
Max. power @ 2.5 GHz (40°C) (kW)
≤1.385
≤1.543
Max. power @ 3.0 GHz (40°C) (kW)
≤1.264
≤1.409
General data
Temp. range operating
(°C)
Temp. range installation
(°C)
Typ. weight
(kg/100m)
Min. bending radius
(mm)
HUBER+SUHNER
–40 / +85
–55 / +85
–40 / +85
–25 / +60
65.0
48
52
120
97
SUCOFEED – Corrugated Cables
1 1/4" high-flex and low attenuation
Order/
type no.
Dimension
SUCOFEED_1 _1/4
SUCOFEED_1 _1/4_FR
1 1/4"
1 1/4"
Cable group
M32
M32
Cable design
Jacket version
standard
flame retardant
Inner conductor
(Ø in mm)
13.10
Dielectric
(Ø in mm)
32.40
Outer conductor
(Ø in mm)
35.80
Jacket
(Ø in mm)
39.50
Electrical data
Typ. operating frequency
(GHz)
Impedance
(W)
Capacitance
(pF/m)
Relative signal propagation
(%)
≤3
50 ± 1
76.5
88
Signal delay
(ns/m)
3.80
Max. operating voltage
(kVrms)
4.20
Typ. attenuation @ 1 GHz
(dB/100m)
2.94
Typ. attenuation @ 2 GHz
(dB/100m)
4.43
Typ. attenuation @ 2.2 GHz
(dB/100m)
4.69
Typ. attenuation @ 2.5 GHz
(dB/100m)
5.08
Typ. attenuation @ 2.7 GHz
(dB/100m)
5.68
Max. power @ 1 GHz (40°C)
(kW)
≤3.120
Max. power @ 2 GHz (40°C)
(kW)
≤2.206
Max. power @ 2.2 GHz (40°C) (kW)
≤2.104
Max. power @ 2.5 GHz (40°C) (kW)
≤1.973
Max. power @ 2.7 GHz (40°C) (kW)
≤1.801
General data
Temp. range operating
(°C)
Temp. range installation
(°C)
Typ. weight
(kg/100m)
Min. bending radius
(mm)
–55 / +85
–40 / +85
–25 / +60
92
110.0
200
For detailed data sheets please go to www.hubersuhner.com and then search for “SUCOFEED”.
98
HUBER+SUHNER
SUCOFEED – Corrugated Cables
1 5/8"
Order/
type no.
Dimension
SUCOFEED_
1_5/8
SUCOFEED_
1_5/8_FR
SUCOFEED_
1_5/8_LA
SUCOFEED_
1_5/8_LA_FR
1 5/8"
1 5/8"
1 5/8" low att.
1 5/8" low att.
Cable group
M42
M42
M43
M43
Cable design
Jacket version
standard
flame retardant
standard
flame retardant
Inner conductor
(Ø in mm)
17.30
17.60
Dielectric
(Ø in mm)
42.40
41.00
Outer conductor
(Ø in mm)
46.50
46.50
Jacket
(Ø in mm)
49.80
50.30
Electrical data
Typ. operating frequency
(GHz)
≤2.75
Impedance
(W)
Capacitance
(pF/m)
76.80
72.50
Relative signal propagation
(%)
87.50
92
50 ± 1
Signal delay
(ns/m)
Max. operating voltage
(kVrms)
5.40
3.80
5.50
Typ. attenuation @ 1 GHz
(dB/100m)
2.43
2.25
Typ. attenuation @ 2 GHz
(dB/100m)
3.71
3.36
Typ. attenuation @ 2.2 GHz
(dB/100m)
3.94
3.56
Typ. attenuation @ 2.5 GHz
(dB/100m)
4.27
3.84
Typ. attenuation @ 2.7 GHz
(dB/100m)
4.48
4.02
Max. power @ 1 GHz (40°C)
(kW)
≤4.100
Max. power @ 2 GHz (40°C)
(kW)
≤2.899
Max. power @ 2.2 GHz (40°C) (kW)
≤2.764
Max. power @ 2.5 GHz (40°C) (kW)
≤2.593
Max. power @ 2.7 GHz (40°C) (kW)
≤2.495
General data
Temp. range operating
(°C)
Temp. range installation
(°C)
Typ. weight
(kg/100m)
Min. bending radius
(mm)
HUBER+SUHNER
–55 / +85
–40 / +80
–55 / +85
–40 / +85
–25 / +60
144.8
160.0
300
110.0
130.0
300
99
SUCOFEED Aluminium – Corrugated Cables
Available types:
Example types:
SUCOFEED_1/2_LW
SUCOFEED_1/2_LW_FR
SUCOFEED_7/8_LW_LA
SUCOFEED_7/8_LW_LA_FR
SUCOFEED_1_5/8_LW_LA
SUCOFEED_1_5/8_LW_LA_FR
100
HUBER+SUHNER
HUBER+SUHNER
101
QUICK-FIT Coaxial Connectors
General description
HUBER+SUHNER QUICK-FIT connectors are worldwide approved N and 7/16 connectors for foam dielectric
corrugated copper tube cables. They offer a greatly simplified and economic approach to cable preparation and
assembly. The product line meets the requirements of multi-carrier, high-channel-count transceivers such as base
stations of today’s mobile communication infrastructure networks.
102
HUBER+SUHNER
Application
• Rugged connectors for easy outdoor termination of corrugated feeder and jumper cables
• Meeting the special requirements of BTS applications
Features
•
•
•
•
•
•
•
Excellent RF performance
Low, stable and reproducible PIM (Passive Intermodulation Product) – typically –165 dBc
Safe assembly process performance – in-field termination with reproducible electrical performance
Quick and easy assembly – 2 main connector parts, 4 steps in less than 4 minutes
High IP rating – IP68
Multi-brand, multi-design and multi-material cable compatibility
Backward compatibility
Benefits
•
•
•
•
•
Easy field installation
Time saving
Simplified logistics
Low cost of ownership
Support quality of a proven connector house
HUBER+SUHNER
103
QUICK-FIT Coaxial Connectors
Technical data
Electrical data
Requirements
Impedance
50 Ω
Frequency range (for connector interface)
N: DC ... 11 GHz
7/16: DC ... 7.5 GHz
VSWR
≤ 1.06 (RL ≥ 30 dB);
PIM
better than -155 dBc
1)
f ≤ 2.5 GHz
1) Carrier to 3rd order intermodulation product ratio with 2 x 20 W (43 dBm) carrier power, f ≤ 1.88 GHz
Mechanical data
Requirements
Recommended coupling nut torque IEC
N: 0.68 ... 1.13 Nm / 0.49 ... 0.82 ft lb. IEC 61169-16
7/16: 25 ... 30 Nm / 18.05 ... 21.66 ft lb. IEC 61169-4
Recommended coupling nut torque HUBER+SUHNER
N: 3 Nm / 2.2 ft lb. with 100 matings max.
Coupling nut retention force
N: ≥ 450 N / 101.2 lbs.
7/16: ≥ 1000 N / 225.0 lbs.
Centre contact
captivated
Durability (matings)
≥ 500
Environmental data
Requirements
Temperature range
– 40°C ... + 85°C / – 40 °F ... + 185 °F
IP rating
IP 68 (acc. to IEC 60529)
Material data
Connector part
Material
Plating
Cable entry
brass
SUCOPLATE®
Connector head
brass
SUCOPLATE®
Outer contact
brass
SUCOPLATE®
Centre contact
spring bronce/brass
silver
Insulators
PTFE or PFA
Gaskets
rubber
Some connectors may have a specification that differs from the above mentioned data. The products are designed
and guaranteed to pass the above mentioned test procedures. Any additional or different requirement arising from
specific applications or environmental conditions which is not covered by these test procedures is subject to request.
104
HUBER+SUHNER
QUICK-FIT Coaxial Connectors
For cable size 1/2"_HF; 1/2"_HF_FR and 1/2"_HF_FR_UL
Type no.
Connector style
Item no.
11_716-50-9-9
DIN 7/16 male
22660309
16_716-50-9-5
DIN 7/16 male
right angle
23007298
21_716-50-9-9
DIN 7/16 female
22660310
11_N-50-9-9
N male
22660311
16_N-50-9-6
N female right angle
23007299
21_N-50-9-9
N female
22660312
Assembly
instruction
Item no.
Stripping tool stripping tool
DOC0000179418
74_Z-0-9-15
23001006
Cable compatibility list on request.
For cable size 1/2"; 1/2"_FR and 1/2”_FR_UL
Type no.
Connector style
Item no.
11_716-50-12-10
DIN 7/16 male
22658311
16_716-50-12-11
DIN 7/16 male
right angle
23011827
21_716-50-12-10
DIN 7/16 female
22658313
11_N-50-12-10
N male
22658314
16_N-50-12-9
N female right angle
23011828
21_N-50-12-10
N female
22658315
Assembly
instruction
Item no.
Stripping tool stripping tool
DOC0000179113
74_Z-0-12-15 23000319
Cable compatibility list on request.
For cable size 7/8"; 7/8"_FR; 7/8”_LA; 7/8”_LA_FR and 7/8"_HF
Type no.
Connector style
Item no.
11_716-50-23-44 DIN 7/16 male
84069135
21_716-50-23-44 DIN 7/16 female
84069194
11_N-50-23-43
N male
84124063
21_N-50-23-43
N female
84124062
Assembly
instruction
Stripping tool
Item no.
stripping tool
DOC74_Z-0-23-18 84074476
0000295365
Cable compatibility list on request.
HUBER+SUHNER
105
QUICK-FIT Coaxial Connectors
For cable size 1_1/4" and 1_1/4"_FR
Assembly
instruction
Stripping/
flairing tool
84116150
DOC0000341341
74_Z-0-32-14/ 23010533/
74_Z-0-32-15 84120843
Connector style
Item no.
Assembly
instruction
Stripping/
flairing tool
11_716-50-42-4
DIN 7/16 male
21_716-50-42-4
DIN 7/16 female
84079343 DOC74_Z-0-42-14/ 23010534/
84079305 0000299051 74_Z-0-42-15 84085074
Type no.
Connector style
Item no.
11_716-50-32-4
DIN 7/16 male
84116088
21_716-50-32-4
DIN 7/16 female
Item no.
stripping tool
Cable compatibility list on request.
For cable size 1_5/8"_LA
Type no.
Item no.
stripping tool
Cable compatibility list on request.
106
HUBER+SUHNER
Tools for QUICK-FIT Coaxial Connectors
Cable stripping tools and spare parts
For easy cable preparation in one single operation (can be used manually or with electrical power tool)
Type no.
Item no.
Part description
1/2” HF
1/2”
7/8”
1 1/4”
74_Z-0-9-15
23001006
stripping tool (1/2” HF)
74_Z-0-12-15
23000319
stripping tool (1/2”)
74_Z-0-23-18
84074476
stripping tool (7/8”)
74_Z-0-32-14
23010533
stripping tool (1_1/4”)
X
74_Z-0-32-15
84120843
flaring tool (1_1/4”)
X
74_Z-0-42-14
23010534
stripping tool (1_5/8”)
1 5/8”
1 5/8”_LA
X
X
X
X
X
74_Z-0-42-15
84085074
flaring tool (1_5/8”)
74_Z-0-0-359
23014976
handle (for stripping tools)
X4)
X4)
X
74_Z-0-0-402
22652193
abrasive paper 320
X
X
74_Z-0-0-424
23001952
spanner AF 17 mm
74_Z-0-0-425
23001953
spanner AF 18 mm
74_Z-0-0-426
23001954
spanner AF 19 mm
74_Z-0-0-427
23001955
spanner AF 21 mm
X
74_Z-0-0-428
23001956
spanner AF 22 mm
X
74_Z-0-0-429
23001957
spanner AF 24 mm
74_Z-0-0-415
22652206
counter sink
optional optional optional
X
optional
X
X
X1)
74_Z-0-0-418
22652209
Stanley knife
74_Z-0-0-420
22652211
steel brush
X
74_Z-0-0-422
22652213
steel measure 200 mm
74_Z-0-0-432
23002005
screw driver 2)
74_Z-0-0-433
23002007
screw driver 4)
74_Z-0-0-12
22642718
small metal saw
74_Z-0-0-434
23002166
monkey wrench
Type no.
Item no.
Part description
74_Z-0-0-347
23000937
blade (cutting corrugated copper tube) for 74_Z-0-12-15
74_Z-0-0-349
23001008
blade (cutting corrugated copper tube) for 74_Z-0-9-15
74_Z-0-0-355
23008264
blade (cutting jacket) for 74_Z-0-32-14
74_Z-0-0-356
23010537
blade (cutting jacket) 74_Z-0-42-14
X2)
X1)
X1)
X1)
X
X
X
X
X
X
X
X
X
X
X2)
X2)
X2)
X2)
X2)
X
X
X
X
X
X
X
X
X
X
X
X
X
X
3)
Type no.
Item no.
Part description
74_Z-0-0-416
22652207
allen wrench AF 2.5 mm/.098 in. for 74_Z-0-9-15, 74_Z-0-12-15, 74_Z-0-32-14 and 74_Z-0-42-14
74_Z-0-0-423
23000311
allen wrench AF 4 mm/.157 in. for removing the BIT adaptor
74_Z-0-0-421
22652212
screwdriver, Torx 1 (Torx T7) for changing the triangle knife 74_Z-0-0-348
1) for assembly use either the Stanley knife or the counter sink
2) only necessary without HUBER+SUHNER stripping tool
3) 2 wrenches are needed for assembling
4) handle included in QUICK-FIT stripping tool delivery
HUBER+SUHNER
107
Cold shrink Tubes for additional Protection
This special cold shrink tube reliably protects coaxial connectors against humidity and harsh environmental influences
like icy conditions or a polluted atmosphere. It especially allows for outdoor feeder line installations in mobile
communications and other wireless systems.
The simple and fast assembly of this cold shrink tube, by pulling out the supporting spiral, enables a reliable installation without special tools. After the assembly the cold shrink tube provides reliable protection by its continuous radial
contact pressure.
Features
•
•
•
•
•
•
Quick and easy installation without tool
No torches or heat required
Accommodates a wide range of cable sizes
Good thermal stability
Resists acids and bases, ozone and UV radiation
Water resistant
Type no.
Item no.
For connector pair
84062968
1/2” HF – 1/2” HF
1/2” HF – 1/2”
1/2” HF – 7/8”
1/2” – 1/2”
1/2” – 7/8”
7/8” – 7/8”
73_Z-0-0-339/---_-E
22658885
1/2” HF – 1 1/4”
1/2” HF – 1 5/8”
1/2” – 1 1/4”
1/2” – 1 5/8”
7/8” – 1 1/4"
7/8” – 1 5/8”
73_Z-0-0-340/---_-Y
22658886
1 1/4” – 1 1/4”
1 1/4” – 1 5/8”
1 5/8” – 1 5/8”
73_Z-0-0-678/---_-E
108
HUBER+SUHNER
Fast-Wrap weatherproofing Kit
Fast-Wrap is a unique, time saving, weatherproofing solution for the telecom industry. The cross-linked butyl on elastomer carrier becomes a powerful sealing mechanism that can withstand the continued assault of outdoor elements
above or below ground. This same material technology has been used successfully for over thirty years in the roofing
and construction industries where it is exposed to the harshest environments. In fact, time and heat only serve to enhance it’s self amalgamation and sealing properties. Fast-Wrap is a comprehensive replacement for common butyl
tape weatherproofing kits and installs three times faster. Unlike butyl tape, Fast-Wrap is clean, easy to cut, simple to
wrap, removable, and will not flow after installation.
Applications
•
•
•
•
•
Outdoor corrugated feeder line to jumper cable connections
Cable to lightning protector or antenna connections
Grounding kits
Fiber or dataline connections above or below ground
Component connections
Colour
Black
Dimensions
2-1/8” x 5 ft
(per roll)
Specific gravity
1.08 +/- .05
tested per ASTM D792-79
Penetration
40/120
tested per ASTM D217 (300Cone)
Ozone/UV resistance
high
tested per ASTM D1149-81 with no
degradation
Elongation
300%
tested per ASTM D412-80
Low temperature
- 49F
tested per ASTM D746
Flash point
350F
tested per ASTM D92
Shear strength
15 PSI min
tested per ASTM D816
Peel strength
3 PSI min.
tested per ASTM D413
Tensile strength
50 PSI max.
v per ASTM D412
Odor
nil
Volatile % by volume
.001 %
Shelf life
10 years
Resistance to
5 % acids, 5 % NaOH, water soluble solvents, acid and basic
soils, heat up to 90 °C for one year, heat spikes at 130 °C for
24 hrs
Do not expose to
Oil, carbon tetrachloride, naphtha, mineral spirits, gasoline
Warranty
3 years
Patent pending
For connector pair
Connections per kit
1-5/8” to 1/2”
2
1-1/4” to 1/2”
2
7/8” to 1/2”
4
1/2” to 1/2”
12
7/8” to device
12
1/2” to device
12
HUBER+SUHNER
Item number:
84125631
109
POLYCON lightweight Connector
This POLYCON family is based on the well established connector series DIN 7/16 and designed for flange
connectors used in indoor and outdoor applications.
110
HUBER+SUHNER
Application
• Outdoor and indoor
Features
•
•
•
•
High corrosion resistance
Light weight
Low and stable intermodulation values
For extreme harsh environments
Benefits
•
•
•
•
•
Cost effective solution
Durability
Excellent electrical values (RL/IL)
No stress corrosion cracking
Good UV radiation resistance
HUBER+SUHNER
111
POLYCON lightweight Connector
Open-air tests at 2500 m (8200 ft) altitude
After having been installed over three years in an extremely harsh environment, the POLYCON connectors were still in
perfect condition and have showed:
• No stress corrosion cracking
• Good UV radiation resistance
• Low stable intermodulation
• Excellent electrical values (RL/IL)
The POLYCON connector body is made of
100% recyclable polymer and marked according to
DIN EN ISO 11469 and ISO 18064
112
HUBER+SUHNER
POLYCON lightweight Connector
Concept and design
The distinctive feature of this design is the separation of the connector body as an electrical part, using well known
materials and surface plating and the mechanical part, which uses injection moulded high-strength polymer.
Electrical part of connector
Inserts according to customer needs
(incl. centre contact and insulator)
Mechanical part of connector
Available polymer bodies: standard and
long neck version
Interface DIN 7/16
Outer contact (insert)
Panel screw
Polymer body
Grounding
Panel
HUBER+SUHNER
113
POLYCON lightweight Connector
Technical data
General
interface standard
temperature
Environmental
flammability
Mechanical
–40 °C to +85 °C
installation
–25 °C to +60 °C
connector on panel
tested acc. UL 94V-0
2002/95/EC (RoHS)
waterproof
Electrical
DIN 7/16, acc. to IEC 61169-4
operating
compliant
(if needed)
IP 68 (20°C / 24 h / 0.1 m, in mated condition)
UV radiation
resistance acc. ISO 4892-2
impedance
50Ω
interface frequency
7.5 GHz
intermodulation (PIM)
better -165 dBc
power handling
0.4 GHz:
0.8 GHz:
1.8 GHz:
2.2 GHz:
2'000 Watt
1'500 Watt
1'000 Watt
800 Watt
coupling nut torque
on panel
20 Nm to 30 Nm
number of matings
on panel
500
Available standard products
Panel connector with M3:
23_716-I50-0-123/00-_-Y
Panel connector for cable:
25_716-I50-5-28/00-_-Y
Further products on request.
114
HUBER+SUHNER
HUBER+SUHNER
115
Lightning Protectors
General description
Four decades of experience in developing and manufacturing coaxial lightning EMP and NEMP protectors are the
foundation of the current HUBER+SUHNER RF-protection portfolio. Our products are designed to meet the stringent
requirements of the RF/microwave, telecommunications and wireless industry and cover civil, security and defense
applications. An extensive high-voltage impulse laboratory has been established to verify our designs in accordance
with the valid international lightning, surge and NEMP standards. Important inventions are covered by worldwide
patents.
116
HUBER+SUHNER
Application
•
•
•
•
•
•
Lightning protection for all mobile communication bands
BIAS-T with lightning protection for applications with active electronics on top of the mast
Lightning protection for active electronics in Point to Point / Backhaul applications
Lightning protection for active electronics in GPS applications
DC block for multiband / site sharing installations with TMAs
DC line protection circuits for Radio Remote Heads in FTTA applications (for details see page 68,
fiber optic chapter "Fiber Optic Interfaces for Remote Radio Heads")
Features
•
•
•
•
•
•
Broadband designs
Excellent RF performance
High lightning current handling capability
Low residual energy
PIM optimized
High CW and PIP power rating
Benefits
•
•
•
•
•
Elevates system availability
Lowers operational risk
LP’s perform the same before and after rated lightning pulses
Best suited for outdoor installations
Easy installation
HUBER+SUHNER
117
Broadband Cellular Lightning Protectors
Application
•
•
•
•
•
λ/4 shorting stub lightning protectors for high power and low PIM applications without DC
Broadband GDT protectors for single channel or low power applications
Hybrid GDT protectors for multiple channel, high power and low PIM applications
Bias–T protectors to support active electronics with DC on top of the mast
Optimized for outdoor installations
Broadband cellular
QUARTER LAMBDA SHORTING STUB 3400
Type no.
3400.17.0431 1)
3400.41.0263 1)
3400.41.0257 1)
Frequency range
690 to 2200 MHz
690 to 2200 MHz
790 to 2620 MHz
Return loss
≥ 24 dB
≥ 26 dB
≥ 20.8 dB
Insertion loss
≤ 0.15 dB
≤ 0.15 dB
≤ 0.1 dB
Supports AISG at
–
–
–
–
–

–

–
–

–
DC interface
–
–
–
PIM 3rd order
≤ –150 dBc
≤ –155 dBc
≤ –150 dBc
RF power (CW) max.
≤ 500 W
≤ 1500 W
≤ 1000 W
RF power (PIP) max.
25 kW
25 kW
–
GDT
n.a.
n.a.
n.a.
max. DC voltage
no DC
no DC
no DC
Surge current (8/20 µs)
single
multiple
50 kA
50 kA
80 kA
80 kA
80 kA
60 kA
Residual energy (typ.) 4 kV 1.2/50 µs; 2 kA 8/20 µs
10 µJ
10 µJ
9 µJ
Ingress protection rating
IP67
IP67
IP68
84080266
3400.17.0431
84092647
3400.41.0263
84062515
3400.41.0257
RF Interface
7/16 female / female
7/16 male / female
N male / female
Order information
Item no.
Type no.
1)
118
LTE = Long term evolution
HUBER+SUHNER
Characteristics and specialities
•
•
•
•
•
•
Excellent RF performance
High lightning current handling capability
Low passive intermodulation
Low residual energy
Supports AISG frequency (2.176 MHz)
25 kW PIP performance allows the multiple channel operation with "Linear Simulcast Modulation Techniques"
GDT 3402
HYBRID 3409
BIAS T 3410
Type no.
3402.41.A 1) and 2)
3409.41.0084 1) and 2)
Frequency range
DC to 2500 MHz
690 to 2200 MHz
690 to 2200 MHz
Return loss
≥ 20 dB
≥ 24 dB
≥ 24 dB
Insertion loss
≤ 0.2 dB
≤ 0.15 dB
≤ 0.1 dB
Supports AISG at
2.176 MHz
2.176 MHz
2.176 MHz

–
–
–

–
–

–
DC interface
–
–
TNC female
PIM 3rd order
n.a.
≤ –155 dBc
≤ –155 dBc
RF power (CW) max.
dep. on GDT
≤ 1500 W
≤ 500 W
RF power (PIP) max.
–
25 kW
25 kW
GDT
max. DC voltage
replaceable
not included
dep. on GDT
replaceable,
9071.99.0548/90 V
≤ 48 V
fix installed,
90 V
≤ 48 V
Surge current (8/20 µs)
single
multiple
30 kA
20 kA
30 kA
20 kA
30 kA
20 kA
Residual energy (typ.) 4 kV 1.2/50 µs; 2 kA 8/20 µs
350 µJ
350 µJ
20 µJ
Ingress protection rating
IP67
IP67
IP67
Item no.
Type no.
22642813
3402.41.A
84092645
3409.41.0084
84115900
3410.41.0029
Item no.
Type no.
–
–
3410.41.0029 1) and 2)
3410.41.0030 1) and 2)
RF Interface
7/16 female / female
7/16 male / female
N male / female
Order information
2)
84115182
3410.41.0030
AISG = Antenna Interface Standards Group
HUBER+SUHNER
119
Cellular Backhaul Lightning Protectors
Application
• Protection of backhaul equipment with coaxial interfaces
• Protection of backhaul equipment with RJ45 interfaces
Cellular backhaul - POINT-TO-POINT radios
GDT 3402
3402.17.0088
Type no.
GDT 3406
3406.17.0027
3402.17.0089
3406.17.0028
Frequency range
0 to 2500 MHz
Return loss
≥20dB
≥20dB
Insertion loss
≤0.2dB
≤0.2dB
RF Interface
N female / female
N male / female
RF power (CW) max.
DC to 4000 MHz
3402.17.0088
3406.17.0027
3402.17.0089
3406.17.0028
dep. on GDT
≤60W
–
–
GDT
replaceable, not included
not replaceable, fix installed, 90 V
Max. DC voltage
dep. on GDT
60 V
Surge current (8/20 µs)
single
30 kA
10 kA
multiple
20 kA
5 kA
I nominal (line-PG)
–
–
Total I nominal (line-PG)
–
–
I nominal (shield-PG)
–
–
RJ45
Residual energy (typ.) 4 kV 1.2/50 µs; 2 kA 8/20 µs 350 µJ
250 µJ
Ingress protection rating
IP65
IP68
84102700
3402.17.0088
84041874
3406.17.0027
Order information
Item no.
Type no.
Item no.
Type no.
120
84102779
3402.17.0089
84041875
3406.17.0028
HUBER+SUHNER
Characteristics and specialities
• Coaxial protector with bandwidth DC to 2500 MHz
• Optional with self extinguishing GDT technology
• Data line protector supports cat.5 class D and
alternatively Gigabit Ethernet cat. 6, class E
• Indoor and outdoor versions available
3414.99.0001
/
3414.99.0008
3414.99.0021
/
3414.99.0022
0
3414.99.0001
for indoor
3414.99.0008
for outdoor
3414.99.0001
Type no.
3414.99.0021
for indoor
3414.99.0022
for outdoor
3414.99.0021
3414.99.0008
3414.99.0022
Frequency range
DC to 100 MHz
DC to 250 MHz
Ethernet cabling standard
cat. 5; class D
cat. 6; class E
Insertion loss
–
–
–
–
–
–
3414.99.0001
3414.99.0021
RF Interface
N female / female
N male / female
RF power (CW) max.
RJ45
3414.99.0008
3414.99.0022
GDT
not replaceable, fix installed
not replaceable, fix installed
Max. DC voltage
58 V between pairs
58 V between pairs
Surge current (8/20 µs)
single
–
–
multiple
–
–
I nominal (line-PG)
2.5 kA
2.5 kA
Total I nominal (line-PG)
10 kA
10 kA
I nominal (shield-PG)
6 kA
shield (connected) to PG
Residual energy (typ.) 4 kV 1.2/50 µs; 2 kA 8/20 µs –
Ingress protection rating
indoor:
–
IP20 (3414.99.0001)
outdoor: IP68 (3414.99.0008)
indoor:
IP20 (3414.99.0021)
outdoor: IP68 (3414.99.0022)
Order information
Item no.
Type no.
Item no.
Type no.
HUBER+SUHNER
23033695
3414.99.0001
84108159
3414.99.0021
84014284
84122191
3414.99.0008
3414.99.0022
121
GPS Lightning Protectors
Application
• Fine protector hybrid technology to protect GPS electronics
Characteristics and specialities
•
•
•
•
Very low residual pulse energy
Full lightning protection (20kA ; 8/20µs)
DC bypass function
Easy bulkhead installation
GPS
Fine protector 3403
3403.17.0060
Type no.
3403.17.0063
Frequency range
800 to 2500 MHz
Return loss
≥ 26 dB
Insertion loss
≤ 0.3 dB
RF Interface
N female / female
N male / female
3403.17.0060
3403.17.0063
DC bypass voltage
other voltage on request
≤6V
DC bypass current
≤4A
Surge current (8/20 µs)
single
20 kA
multiple
10 kA
Residual energy (typ.) 4 kV 1.2/50 µs; 2 kA 8/20 µs
6 µJ
Ingress protection rating
IP67
Order information
Item no.
Type no.
Item no.
Type no.
122
84030303
3403.17.0060
84038163
3403.17.0063
HUBER+SUHNER
DC Block
Application
• Blocking of DC (galvanic isolation of the inner conductor)
• Blocking or reducing of switching transients on transmission lines
Characteristics and specialities
•
•
•
•
•
•
Braodband operation for all cellular bands
Max. operation DC voltage ≤ 1 kV
Isolation @ 1 kHz ≥ 80 dB
Robust and compact
Low weight
IP67 rated
DC block
DC block 9077
Type no.
9077.41.0035
Frequency range
350 – 3000 MHz
650 – 2700 MHz
Return loss
≥ 20 dB
≥ 26.5 dB
Insertion loss
≤ 0.1 dB
Interface
7/16 male /
female
RF power (CW) max.
750 W, 10 kW
(peak)
RF power (PIP) max.
25 kW
PIM 3rd order
≤ –160 dBc typ.
DC blocking voltage
≤ 1kV
Isolation
at 100 kHz
≥ 40 dB
at 10 kHz
≥ 60 dB
at 1 kHz
≥ 80 dB
Ingress protection rating
IP67
Order information
Item no.
Type no.
HUBER+SUHNER
84082135
9077.41.0035
123
Gas Discharge Tube (GDT)
Gas discharge tubes
The best fitting gas discharge tube (GDT) can be selected according
to the applied continuous RF power. If a DC signal is superimposed on
the RF transmission line follow the guidelines given in the Lightning
protection catalogue.
Type no.
9071.99.0547
9071.99.0548
UZstat
(V)
230 ±15 %
90 ±20 %
Item no.
23034582
23011009
UZdyn max.
(V)
675
500
IS 8/20 µs
(kA)
20
20
ISG 8/20 µs
(kA)
30
30
UARC
(V)
10 – 15
10 – 15
Dim.
(mm)
6x8
6x8
Ÿ6\VWHP
3:
9
9
*5HIOHFWLRQIDFWRU
124
96:5
HUBER+SUHNER
SEMPER™ – self-extinguishing Gas Discharge Tube with automatic Recovery
Features and benefits
• Self-extinguishing gas discharge tube with automatic recovery
• Extinguishing under any coaxial line condition including:
– Malfunction of electronic fused DC supplies
– Malfunction of RF line monitoring
– Absence of any such mechanism
• Can be employed for any HUBER+SUHNER GDT protector with
exchangeable gas tube
• Field replacement allows cost-effective system upgrades
• Product options ensure availability for any application
• Higher safety
• Negligible system downtime
SEMPER™ GDT units for retrofit and replacement for series 3401 and 3402
Type no.
9071.99.0647
9071.99.0648
Item no.
84015427
84010426
UZstat
(V)
230 ± 15 %
90 ± 20 %
UZdyn max.
(V)
675
500
IS 8/20 µs
(kA)
20
20
ISG 8/20 µs
(kA)
30
30
UARC
(V)
10 – 15
10 – 15
ISG 8/20 µs
(kA)
30
30
UARC
(V)
10 – 15
10 – 15
SEMPER™ GDT units for retrofit and replacement for series 3409
Type no.
9071.99.0747
9071.99.0748
Item no.
84014462
84014401
UZstat
(V)
230 ± 15 %
90 ± 20 %
UZdyn max.
(V)
675
500
IS 8/20 µs
(kA)
20
20
Sectional view of SEMPER™ GDT module
GDT capsule holder
Liquid silicone rubber
Switch gap closed in normal state
Switch gap open in activated state
Gas discharge tube
HUBER+SUHNER
125
Grounding Kits
Application
• Series 9076 grounding kits enable reliable outdoor
grounding of today’s usual corrugated copper tube and
RG cables for radio transmitter antenna installations.
Characteristics and specialities
•
•
•
•
•
•
•
126
Quick and easy installation
No loose parts
Lowcontacttransitionresistance(1mΩmax.)
Grounding cable AWG 6 (16 mm2)
Current handling capability 100 kA, 8/20 µs; 25 kA, 10/350 µs
Waterproof IP67
Corrosion resistant
HUBER+SUHNER
Grounding Kits
For cable size SUCOFEED
"A" (mm)
"B" (mm)
"C" (mm)
Stripping
length (mm)
Grounding
screw
Type no.
Item no.
Andrew, Nokia, Kabelmetal,
RFS, Eupen, etc.
9076.99.N013-50
84124422
1/2” highflex
500
50
32
26
M8
9076.99.N012-50
84124423
1/2”
500
50
32
26
M8
9076.99.N078-50
84069990
7/8”, 7/8” highflex
500
50
44
26
M8
9076.99.N114-50
84069991
1 1/4”
500
50
59
26
M8
9076.99.N158
23012647
1 5/8”
840
70
69
30
M8
HUBER+SUHNER
127
Accessories for Conventional Cell Sites
General description
We offer a large selection of advanced products, which are rich in exclusive features and highly appreciated by the
operators of leading companies in the sector because we provide total fastening safety along with practical and
easy mounting.
128
HUBER+SUHNER
Application
• Secure fixing of the corrugated, fiberoptic and DC cables on the mast
Features
• Small structure
• Resistance to atmospheric factors (rays and salty air)
• Fixing of 1 to 8 coaxial cables depending on version
Benefits
• Solutions for conventional and FTTA available
• Secured components for easy and quick installation
• Absolute safety for cables and installer
HUBER+SUHNER
129
Accessories for Conventional Cell Sites
General:
This product summary shows only a small range of products. Clamps for other profiles or cable types on request.
RFM self clamping hanger
Main features
Description
For profile
Picture
For profile
Picture
For profile
Picture
•Easy and quick installation
•Resistance to atmospheric factors
•SAS single saddle or SAT twin saddle
Components
•Metal bow
•Hexagon headed locking screw
•Metal pressure plate
Material
USC single clamp
Main features
•Stainless steel AISI 301
•Reglas reinforced polyamide, black
Description
•Space-saving block
•Resistance to atmospheric factors
•SAM single saddle
•Threaded bar M8
Components
•Flat washer RPI 10/20
•Hexagonal nuts UNI 5588
•Flexible hinge
•Adapter self locking M8 (compact clamp)
Material
UCC twin clamp
Main features
•Stainless steel AISI 304 (V 2A)
•Reglass HDPE., UV proof, black
Description
•Space-saving block
•Resistance to atmospheric factors
•SAB twin saddle
•Threaded bar M8
Components
•PUC steel-flanges
•Hexagonal nuts UNI 5588
•Elastic washer DIN 6798
•Adapter self locking M8 (compact clamp)
Material
130
•Stainless steel AISI 304 (V 2A)
•Reglass HDPE, UV proof, black
HUBER+SUHNER
LCC quick-fit fastener
Main features
Description
For profile
Picture
For profile
Picture
•Easy and quick installation
•Resistance to atmospheric factors
•SAL twin saddle
•Threaded bar M8
Components
•PSL steel-flanges
•Hexagon nuts UNI 5588
•Elastic washer DIN 6798
•Adapter self locking M8 (compact clamp)
Material
•Stainless steel AISI 304 (V 2A)
•Reglass HDPE, UV proof, black
SCM click collar
Description
Main features
•Easy and quick installation
Components
Material
HUBER+SUHNER
•Metal collar
•Adapter M6 (compact clamp)
•Stainless steel AISI 304 (V 2A)
131
Accessories for Conventional Cell Sites
Type: RFM
Self clamping hanger with calibrated saddles for flat 3 – 25 mm
and round 8 – 25 mm profile
Main features:
• Easy and quick installation
• Resistance to atmospheric factors
Components:
•
•
•
•
Single saddle SAS or twin saddle SAT
Metal bow
Hexagon headed locking screw
Metal pressure plate
Material:
• Stainless steel AISI 301
• Reglass reinforced polyamide, black
Number of cables:
1x
Cable type
1/2" (Ø17)
7/8" (Ø28)
1-1/4" (Ø40)
2x
H+S description
3x
No. of
cables
Item no.
4x
Quantities
kit with
Weight
in g
6x
L (mm)
L1 (mm)
h1 (mm) h2 (mm)
RFM_1556_0012
1x
84107915
50 pcs
68
22
28
34
63
RFM_1556_0212
2x
84107916
50 pcs
98
22
28
63
90
RFM_1556_0312
3x
84107917
50 pcs
126
22
28
91
117
RFM_1556_0412
4x
84107918
50 pcs
160
46
53
58
93
RFM_1556_0612
6x
84107919
50 pcs
185
46
53
85
117
RFM_1556_0078
1x
84045465
50 pcs
108
34
41
46
74
RFM_1556_0278
2x
84045466
50 pcs
166
34
41
87
112
RFM_1556_0378
3x
84045467
50 pcs
223
34
41
128
150
RFM_1556_0478
4x
84107920
25 pcs
240
70
77
83
117
RFM_1556_0678
6x
84107921
25 pcs
276
70
77
123
153
RFM_1556_0114
1x
84107922
50 pcs
153
46
53
58
92
RFM_1556_2114
2x
84107923
50 pcs
238
46
53
111
143
RFM_1556_3114
3x
84107925
50 pcs
322
46
53
165
194
RFM_1556_0158
1x
84107926
25 pcs
188
58
65
72
105
1-5/8" (Ø52) RFM_1556_2158
2x
84045469
25 pcs
211
58
65
137
169
RFM_1556_3158
3x
84045470
25 pcs
403
58
65
202
233
132
HUBER+SUHNER
Type: USC
Single clamp with elastic cushions including angle adapter for flat and angular 3 - 25 mm
and round 8 – 26 mm profile
Main features:
• Space-saving block
• Resistance to atmospheric factors
Components:
•
•
•
•
SAM single saddle, threaded bar M8
RPI 10/20 flat washer, hexagonal nuts UNI 5588
Flexible hinge
Adapter self locking M8 (compact clamp)
Material:
• Stainless steel AISI 304 (V 2A)
• Reglass HDPE, UV proof, black
Number of cables:
1x
Cable type
1/2" (Ø17)
7/8" (Ø28)
1-1/4" (Ø40)
2x
3x
H+S description
No. of
cables
USC_1572_0012
1x
Item no.
84107927
Quantities
kit with
Weight
in g
H (mm)
h1 (mm)
L (mm)
20 pcs
105
75
27
34
USC_1572_0212
2x
84107928
20 pcs
130
100
54
34
USC_1572_0312
3x
84107929
20 pcs
155
125
81
34
USC_1572_0078
1x
84107930
20 pcs
132
100
38
45
USC_1572_0278
2x
84107931
20 pcs
170
125
76
45
USC_1572_0378
3x
84107932
20 pcs
207
200
114
45
USC_1572_0114
1x
84107933
20 pcs
155
100
54
57
USC_1572_2114
2x
84107934
20 pcs
200
200
108
57
UCS_1572_3114
3x
84107935
20 pcs
245
250
150
57
USC_1572_0158
1x
84107936
20 pcs
155
125
66
68
1-5/8" (Ø52) USC_1572_2158
2x
84107937
20 pcs
200
200
132
68
USC_1572_3158
3x
84107938
20 pcs
290
300
198
68
HUBER+SUHNER
133
Accessories for Conventional Cell Sites
Type: UCC
Twin clamp with elastic cushions including angle adapter for flat 3 – 25 mm
and round 8 – 26 mm profile
Main features:
• Space-saving block
• Resistance to atmospheric factors
Components:
•
•
•
•
Twin saddle SAB, threaded bar M8
PUC steel-flanges, hexagonal nuts UNI 5588
Elastic washers DIN 6798
Adapter self locking M8 (compact clamp)
Material:
• Stainless steel AISI 304 (V 2A)
• Reglass HDPE, UV proof, black
Number of cables:
2x
Cable type
1/2" (Ø17)
7/8" (Ø28)
1-1/4" (Ø40)
4x
H+S description
6x
No. of
cables
Item no.
Quantities
kit with
Weight
in g
H (mm)
h1 (mm)
L (mm)
75
27
68
UCC_1560_0212
2x
84107943
20 pcs
210
UCC_1560_0412
4x
84107944
20 pcs
260
125
54
68
UCC_1560_0612
6x
84107945
20 pcs
310
150
81
68
UCC_1560_0278
2x
84107946
20 pcs
265
100
38
90
UCC_1560_0478
4x
84107947
20 pcs
340
150
76
90
UCC_1560_0678
6x
84107949
20 pcs
415
200
114
90
UCC_1560_2114
2x
84107950
20 pcs
310
150
54
114
UCC_1560_4114
4x
84107951
20 pcs
400
200
108
114
UCS_1560_6114
6x
84107953
20 pcs
490
250
150
114
UCC_1560_2158
2x
84107954
20 pcs
310
150
66
137
1-5/8" (Ø52) UCC_1560_4158
4x
84107955
20 pcs
400
250
132
137
UCC_1560_6158
6x
84107956
20 pcs
580
300
198
137
134
HUBER+SUHNER
Type: LCC
Quick-fit fastener with elastic cushions including angle adapter for flat and
angular 3 – 25 mm and round 8 – 26 mm profile
Main features:
• Easy and quick installation
• Resistance to atmospheric factors
Components:
•
•
•
•
SAL twin saddle, threaded bar M8
PSL steel flanges, hexagonal nuts UNI 5588
Elastic washers DIN 6798
Adapter self locking M8 (compact clamp)
Material:
• Stainless steel AISI 304 (V 2A)
• Reglass HDPE, UV proof, black
Number of cables:
2x
Cable type
1/2" (Ø17)
7/8" (Ø28)
1-1/4" (Ø40)
4x
6x
H+S description
No. of
cables
LCC_1563_2012
2x
Item no.
84107958
Quantities
kit with
Weight
in g
H (mm)
h1 (mm)
L (mm)
20 pcs
240
75
30
62
LCC_1563_4012
4x
84107960
20 pcs
270
100
54
62
LCC_1563_6012
6x
84107962
20 pcs
300
125
84
62
LCC_1563_2078
2x
84107964
20 pcs
250
75
41
84
LCC_1563_4078
4x
84107965
20 pcs
290
125
79
84
LCC_1563_6078
6x
84107966
20 pcs
330
150
117
84
LCC_1563_2114
2x
84107968
20 pcs
280
100
53
102
LCC_1563_4114
4x
84107970
20 pcs
350
150
103
102
LCS_1563_6114
6x
84107971
20 pcs
420
200
153
102
LCC_1563_2158
2x
84107973
20 pcs
310
100
64
119
1-5/8" (Ø52) LCC_1563_4158
4x
84107974
20 pcs
390
200
125
119
LCC_1563_6158
6x
84094910
20 pcs
470
250
186
119
HUBER+SUHNER
135
Accessories for Conventional Cell Sites
Type: SCM
Click collar made in metal including angle adapter for flat and angular 3 – 25 mm
and round 8 – 26 mm profile
Main features:
• Easy and quick installation
Components:
• Metal collar
• Adapter M6 (compact clamp)
Material:
• Stainless steel AISI 301
Number of cables:
1x
Cable type
H+S description
No. of
cables
Item no.
Quantities
kit with
Weight
in g
H (mm)
1/2" (Ø17)
SCM_2012_4013
1x
84107976
20 pcs
77
44
7/8" (Ø28)
SCM_2012_4020
1x
84107977
20 pcs
80
55
1-1/4" (Ø40)
SCM_2012_4030
1x
84107979
20 pcs
85
67
1-5/8" (Ø52) SCM_2012_4150
1x
84107980
20 pcs
88
79
136
HUBER+SUHNER
HUBER+SUHNER
137
Power Splitters
General description
The RF power splitters are low loss reactive splitters for the distribution of RF signals to radio transceiver antenna
systems and radiating cables. The RF power is equally distributed to all outputs with excellent amplitude and phase
balance.
A broad range of power splitters with N, DIN 7/16 and SMA connectors has been designed to split even high
power multi-carrier signals of all existing mobile phone systems. Multiband units simplify logistics for OEMs and
multi-system operators. Smaller units with SMA connectors can be provided for picocell wireless communication
systems.
138
HUBER+SUHNER
Application
• Power splitters for most mobile communication bands
• RF signal distribution to antennas and radiating cables
• 2-way, 3-way or 4-way RF-power splitting
Features
•
•
•
•
•
•
•
•
•
Superior RF performance, low VSWR and insertion loss
50ΩImpedance
PIM level typically -150 dBc (3rd order, N and 7/16 connector styles)
Available in the frequency range from 800 MHz to 6 GHz
2-way, 3-way and 4-way configurations
DC continuity for outdoor powering
Rugged and reliable design
Waterproof IP 65 (N and 7/16 connector styles)
Protective cover kit optionally for outdoor installations available
Benefits
• Cost efficient solution for connecting a couple or more antennas to only one radio transceiver
• Installer friendly robust design
HUBER+SUHNER
139
Power Splitters
Functionality
Nominal split loss
Isolation between ports
2 way splitters
3.0 dB
3 way splitters
4.8 dB
4 way splitters
6.0 dB
2 way splitters
6.0 dB
3 way splitters
9.5 dB
4 way splitters
12.0 dB
Specifications
Operation temperature range
-40°C…+85°C / -40°F…+185°F
Waterproof degree
(IEC 60529)
IP65 (SMA styles IP64)
Temperature shock
MIL-STD-202, Meth. 107, Cond. B
Moisture resistance
MIL-STD-202, Meth. 106
Vibration
MIL-STD-202, Meth. 204, Cond. D
We recommend additional taping for long term outdoor applications.
DIN 7/16 types with frequency range 800 – 2500 MHz
Type no.
5502.41.0026
5502.41.0027
5502.41.0028
Item no.
84020588
84023443
84023731
Split
2-way
3-way
4-way
Frequency
800 - 2500 MHz
800 - 2500 MHz
800 - 2500 MHz
Input port
7/16 female
7/16 female
7/16 female
Output port
7/16 female
7/16 female
7/16 female
Return loss (input)
min. 20 dB
min. 20 dB
min. 20 dB
Insertion loss
typ. 0.3 dB
typ. 0.3 dB
typ. 0.2 dB
Average power
500 W
500 W
500 W
IP rating
IP65
IP65
IP65
Weight
0.85 kg
0.95 kg
1.05 kg
LTE versions available in July 2011
140
HUBER+SUHNER
Power Splitters
N types with frequency range 2000 – 6000 MHz
Type no.
5504.17.0004
5504.17.0005
Item no.
84005364
84011465
Split
2-way
2-way
Frequency
2000 - 6000 MHz
2000 - 6000 MHz
Input port
N male
N female
Output port
N female
N female
Return loss (input)
min. 20 dB
min. 20 dB
Insertion loss
typ. 0.2 dB
typ. 0.2 dB
Average power
300 W
300 W
IP rating
IP65
IP65
Weight
0.8 kg
0.8 kg
SMA types with frequency range 2000 - 2500 MHz
Type no.
5502.19.0004
5502.19.0005
5502.19.0006
Item no.
22650303
22650304
22650305
Split
2-way
3-way
4-way
Frequency
2000 - 2500 MHz
2100 - 2500 MHz
2100 - 2500 MHz
Input port
SMA male
SMA male
SMA male
Output port
SMA female
SMA female
SMA female
Return loss (input)
min. 19 dB
min. 17.5 dB
min. 16.5 dB
Insertion loss
typ. 0.2 dB
typ. 0.2 dB
typ. 0.2 dB
Average power
100 W
100 W
100 W
Weight
0.012 kg
0.014 kg
0.015 kg
HUBER+SUHNER
141
Power Splitters – Accessories
The protective cover kit suitable for series 5500 and
5502 provides additional protection for RF Power Splitters exposed to harsh environmental conditions.
Important: The installation of the protective kit requires
right angle adaptors on all output ports. Since series
5500 and 5502 are supplied with straight connector
shapes (female) only, you will have to use either jumpers
with right angle interfaces (male) or separately ordering
right angle adaptors as listed below.
Type no.
Item no.
Suitable for
Weight (kg)
73_Z-0-0-614/---_-E
84072501
Series 5500 / 5502
0.4334
The protective cover kit includes the protective cover with screw M8x1 and screw fixation cord and rubber bellows
with hose clamp.
Right angle adaptors to be ordered separately
1 adapter required per output port
Type no.
53_N-50-0-4/133_UE
53_716-50-0-1/003_-E
Item no.
22658908
22641259
Shape
right angle adaptor
right angle adaptor
Connector series
N
7/16
Connector gender
plug/jack [m/f]
plug/jack [m/f]
Mounting hardware
This mounting hardware allows you to fix series 5500
and 5502 RF power splitters on masts of 40 to 360 mm
diameter by means of non corrosive steel hose clamps.
It can be used for wall mounting (2 x 8.0 mm diameter
holes) too.
Type no.
Item no.
Suitable for
For mast diameter
Weight (kg)
9075.99.0001
22648739
Series 5500 / 5502
40 - 50 mm
0.35
9075.99.0002
22648738
Series 5500 / 5502
50 - 360 mm
0.45
One set consists of a complete bracket plus two steel hose clamps adjusted to the selected mast diameter.
142
HUBER+SUHNER
HUBER+SUHNER
143
Low PIM and Cable Impairment Test Kit
Features
• Use of high performing PIM components
– N and DIN 7/16
– Load
– Standard / source
Benefits
• Existing and approved technology
• All components are available for on-site
IM testing
• High mating cycles
Technical data
Electrical
Impedance
50Ω
Frequency range
690 MHz to 2700 MHz
RF CW power
50 W
Environmental
Operating temperature
0 °C up to +40 °C
2002/95/EC (RoHS)
compliant
Mechanical
Number of matings
500 with max. torque of 30 Nm for DIN 716 or max. torque of 1 Nm for N interfaces,
increased torque may reduce the number of matings significantly
Material
Piece part
Material
Surface Plating
Body
Brass
Tri-metal plating
Centre contact female
Copper beryllium alloy
Gold plating / Silver plating / Tri-metal plating
Centre contact male
Brass
Gold plating / Silver plating / Tri-metal plating
Order information
Low PIM and cable impairment test kit, item no. 84108289
144
HUBER+SUHNER
Low PIM and Cable Impairment Test Kit
Kit content
Part ID
Description
Configuration
(connector series – gender)
PIM Adapter, ≤ -155dBc, 3rd order IM level, at 2 x 43 dBm
(2 x 20 Watt) carrier power
ADP-1
adapter 1
DIN 7/16 female – female
ADP-2
adapter 2
DIN 7/16 male – male
ADP-3
adapter 3
DIN 7/16 male – female
ADP-4
adapter 4
N male - DIN 7/16 female
ADP-5
adapter 5
N female - DIN 7/16 female
ADP-6
adapter 6
N male - DIN 7/16 male
ADP-7
adapter 7
DIN 7/16 male - N female
ADP-8
adapter 8
N female – female
PIM Standard, adjusted to -57 dBm for 3rd order IM level,
at 2 x 43 dBm (2 x 20 Watt) carrier power
IMS-1
IM standard 1,
at 900 MHz
DIN 7/16 male – female
IMS-2
IM standard 2,
at 1800 MHz
DIN 7/16 male – female
PIM Load, ≤ -155dBc, 3rd order IM level, at 2 x 43 dBm (2 x 20 Watt) carrier power
LOD-1
Load termination 1
DIN 7/16 male and female
Part ID
Description
Configuration
(connector series – gender)
Open Circuit, ≤ -155 dBc typ. for 3rd order PIM performance
OPN-1
open circuit 1
N male
OPN-2
open circuit 2
N female
OPN-3
open circuit 3
DIN 7/16 male
OPN-4
open circuit 4
DIN 7/16 female
Short Circuit, ≤ -155 dBc typ. for 3rd order PIM performance
SHT-1
short circuit 1
N male
SHT-2
short circuit 2
N female
SHT-3
short circuit 3
DIN 7/16 male
SHT-4
short circuit 4
DIN 7/16 female
50 Ω Termination, power rating: 1 W, VSWR max.: 1.1 for N series; 1.15 for DIN 7/16 series, no PIM rating
TRM-1
fixed
termination 1
N male
TRM-2
fixed
termination 2
N female
TRM-3
fixed
termination 3
DIN 7/16 male
TRM-4
fixed
termination 4
DIN 7/16 female
HUBER+SUHNER
145
Radio Frequency Antennas and Microwave Modules
Wireless communication applications have taken off over the past years. In addition to voice services, wireless
systems are now also handling an increasing volume of data traffic, with the demand being for high transmission
capacities.
To provide these capacities, mobile radio cells (GSM, UMTS and LTE) are steadily shrinking, allowing multiple use of
frequency bands, which in turn enables capacity to be increased.
HUBER+SUHNER provides application specific antennas for base station synchronization and microwave modules
for Radio Access Network (RAN).
146
HUBER+SUHNER
GPS Antennas
General description
Accurate timing, phase and frequency synchronisation are essential for today’s wireless networks in the field of digital
communication. Handover, TDD scheduling, interference cancellation and terminal location tracking are based on
GPS or Glonass time reference.
HUBER+SUHNER offers a high-quality portfolio of standard and customised GPS and GLONASS antennas for the
synchronisation of mobile communication base stations and the support of position detection for mobile terminal
equipment.
The GPS/Glonass antennas are equipped with a low-noise preamplifier and are provided with integral lightning and
overvoltage protection. This is of crucial importance in view of the often exposed position of the antennas. Through
the location of the EMP protection in the antennas, separate installation of an external EMP protection can be dispensed with. The antennas thus combine compact size with optimal functionality and reliability.
Applications
• For timing and frequency synchronisation in cellular
base stations derived from the GPS or
GLONASS signal
• Use in position-detection systems for the tracking of
mobile terminal equipment
Features
• Small and unobtrusive design
• Low-noise preamplifier for compensation of antenna
cable loss
• Amplifier feed via antenna cable
• Integrated lightning and overvoltage protection
• Cone-shaped radome prevents snow, ice and dirt
deposits
• Mounting bracket for mast and wall mounting included in the scope of supply
Benefits
• Reliably supports timing and frequency
synchronisation in mobile communication networks
• Can be used with all standard GPS/GLONASS
receivers
• Simple and time-saving installation; no special tools
required
• Easy commissioning
HUBER+SUHNER
147
GPS Antennas
Product overview
Type no.
Item no.
1315.17.0026
84119684
1315.17.0028
84121280
1315.17.0027
84119712
1315.17.0029
84121325
1316.17.0002
84061412
1316.17.0001
84058690
Frequency [MHz]
1565 – 1585 (GPS)
1565 – 1585 (GPS)
1565 – 1625 (GPS + GLONASS)
Antenna gain [dB]
5
5
5
Antenna gain @
10° elevation [dB]
2
2
–
LNA gain [dB]
31
40
40
Noise figure [dB]
3
3
3.5
VSWR
Operational voltage
Current consumption
Lightning protector
Radome colour
Mounting bracket
148
1.8
1.8
2
4V-6V DC
4V-6V DC
4V-6V DC
50 mA
50 mA
50 mA
integrated
integrated
integrated
RAL 9003(signal white)
L- shape bracket
for pole and wall
mounting included
bracket not included
RAL 9003(signal white)
L- shape bracket
for pole and wall
mounting included
bracket not included
RAL 7035(light grey)
L- shape bracket
for pole and wall
mounting included
bracket not included
HUBER+SUHNER
SENCITY®LINK 60
General description
Network deployments in urban areas, especially LTE technology, have brought in a reduction of cell size of up to 600
m. Therefore 60 GHz point-to-point links are being used by wireless carriers for the backhaul applications of radio
base stations. The benefits of SL60 for cellular backhaul are the extremely small size, the interference free frequency
band due to oxygen absorption at 60 GHz and the high data rate of the links thanks to huge spectrum availability.
SL60 is very convenient for deployments under the roof top or on street level. Its size and flat panel antenna
technology allows packing the radio and BTS into the same enclosure.
Application
• Radio Access Network (RAN) backhaul
Features
•
•
•
•
•
•
•
Transparent point-to-point ethernet connection
Data rate up to 1’000 Mbps full-duplex
License free
Optical alignment
Low power
Distance up to 1’600 m
Supports SNMP
Benefits
• Low-profile design
• Small and lightweight equipment with integrated
antenna
• Low installation costs
• Easy and fast installation
• Interference-free
• High data rates
• Remote manageable
HUBER+SUHNER
149
SENCITY®LINK 60
Product portfolio
Type no.
SL60-401
SL60-501
SL60-4010
Item no.
84092438
84092442
84119340
Data throughput wireless
680 MBit/s
340 MBit/s
220 MBit/s
Net throughput for full duplex via
cable
320 MBit/s
160 MBit/s
100 MBit/s
Coverage
800 m
1.600 m
800 m
Dimensions
182 x 182 x 68 mm
Availability
up to 99.999%
Antenna gain
Frequency range
Weight
Power consumption
38 dBi
59.5 / 62.0 GHz (FDD)
2.5 kg
18 W POE (IEEE802 3at)
Assembly
Alignment unit and telescope
Ambient conditions
ETSI EN 300 019-2-4 T 4.1E
Connection
RJ45 outdoor
For more information please visit our website: www.sl60.com/products
150
HUBER+SUHNER
SENCITY®LINK 60
The influence of weather conditions
The Sencity®Link 60 is not susceptible to fog or snow and can be used in all weather conditions. Heavy rain damps
the signal, so that the maximum distance is temporarily reduced.
Rain
SL60 - 4010
800 m
680 m
SL60 - 401
800 m
680 m
540 m
540 m
SL60 - 501
1600 m
1200 m
960 m
SL60 - 4010
800 m
800 m
800 m
SL60 - 401
800 m
800 m
800 m
SL60 - 501
1600 m
1600 m
1600 m
SL60 - 4010
800 m
800 m
800 m
SL60 - 401
800 m
800 m
800 m
SL60 - 501
1600 m
1600 m
1600 m
Fog
Snow
HUBER+SUHNER
151
Sencity®Link 60
Accessories
PoE injector
•100-250VAC universal input
84021333
•Power ON LED
•10/100/1000 (Mbps) data rates
•Desktop style / non-vented case for indoor use
Data-line protector
•Power over ethernet
84122191
•Hybrid protector
•Shield and ground separated
•All lines protected
Mast bracket
84015652
•Mast diameter 50 – 115 mm
•Stainless steel (M8)
Alignment scope
•The optical alignment tool is easily mounted on the terminal. It
enables both ends of the link to be aligned quickly, simply and
independently
84082886
84031068
84028025
84028026
84041974
84028029
152
(2 m)
(10 m)
(30 m)
(50 m)
(90 m)
Outdoor ethernet cable
•S/STP Cat. 7, 1200MHz
•UV stable
•UL approved
HUBER+SUHNER
HUBER+SUHNER
153
Your Contacts at HUBER+SUHNER. Wherever you are.
AUSTRALIA
HUBER+SUHNER (Australia) Pty Ltd
Unit 6, 4 Skyline Place Frenchs Forest
AU-Sydney NSW 2086
Tel. +61 (0)2 8977 1200
Fax +61 (0)2 9972 7549
info.au@hubersuhner.com
BRAZIL
HUBER+SUHNER América Latina Ltda
Av. Rui Barbosa, 3613 Alto da Ponte
BR-12212-531 São José dos Campos-SP
Tel. +55 12 3946 9500
Fax +55 12 3946 9528
info.br@hubersuhner.com
CHINA
HUBER+SUHNER (Hong Kong) Ltd
Unit 1101 & 1121, Level 11, Tower 1
Grand Central Plaza
No. 138 Shatin Ruralo Committee Road
Shatin, N.T., HK-Hong Kong
Tel. +852 2866 6600
Fax +852 2866 6313
info.hk@hubersuhner.com
HUBER+SUHNER (Shanghai) Co., Ltd
Part B 2-3, 2/F
333 Fu Te Xi Yi Road Waigaoqiao
CN-Shanghai 200131, P.R. China
Tel. +86 (0) 21 5899 3808
Fax +86 (0) 21 5899 1860
infoshanghai@hubersuhner.com
HUBER+SUHNER (Shanghai)
Transmission & Communication
Manufacture Co., Ltd
1330, Jin Hu Road
Jin Qiao, Pu Dong New District
CN-Shanghai 201206, P.R. China
Tel. +86 (0) 21 5899 3808
Fax +86 (0) 21 5899 1860
infoshanghai@hubersuhner.com
DENMARK
HUBER+SUHNER A/S
Kirke Vaerløsevej 14
DK-3500 Vaerløse
Tel. +45 48 100 500
Fax +45 48 100 555
info@hubersuhner.dk
FRANCE
HUBER+SUHNER France
21 E, rue Jacques-Cartier
FR-78960 Voisins-le-Bretonneux
Tel. +33 (0)1 61 37 25 55
Fax +33 (0)1 30 64 73 68
info.fr@hubersuhner.com
GERMANY
SwITZERLAND
HUBER+SUHNER GmbH
Mehlbeerenstr. 6
DE-82024 Taufkirchen
Tel. +49 (0)89 612 01 0
Fax +49 (0)89 612 01 162
info.de@hubersuhner.com
HUBER+SUHNER AG
CH-9100 Herisau
Tel. +41 (0)71 353 41 11
Fax +41 (0)71 353 44 44
info@hubersuhner.com
HUBER+SUHNER AG
CH-8330 Pfäffikon ZH
Tel. +41 (0)44 952 22 11
Fax +41 (0)44 952 24 24
info@hubersuhner.com
INDIA
HUBER+SUHNER Electronics
Private Limited
682, Udyog Vihar, Phase V
IN-Gurgaon 122 016, Haryana
Tel. +91 (0)124 410 27 01/02/03
Fax +91 (0)124 410 27 04
info.in@hubersuhner.com
THAILAND
HUBER+SUHNER
(Thailand) Co., Ltd.
2210/64
Narathiwatratchanakharin Road
Kwaeng Chongnonsee
Khet Yannawa
TH-Bangkok 10120
Tel. +66 (0)2 285 4277
Fax +66 (0)2 285 4278
info.th@hubersuhner.com
MALAYSIA
HUBER+SUHNER
(Malaysia) Sdn. Bhd.
Lot 24, Jln Pengacara U1/48
Temasya Industrial Park
40150 Shah Alam
MY-Selangor
Tel. +60 3 7628 0202
Fax +60 3 7628 0303
sales.my@hubersuhner.com
GREAT BRITAIN
HUBER+SUHNER (UK) Limited
Telford Road
GB-Bicester
Oxfordshire OX26 4LA
Tel. +44 (0)1 869 364 100
Fax +44 (0)1 869 249 046
info.uk@hubersuhner.com
POLAND
HUBER+SUHNER Sp. z o.o.
Ul. Baldowska 26
PL-83-110 Tczew
Tel. +48 58 560 2100
Fax +48 58 560 2172
info.pl@hubersuhner.com
USA
HUBER+SUHNER, Inc.
19 Thompson Drive
US-Essex Jct.
VT 05452
Tel. +1 800 493 9758
Fax +1 802 878 9880
info.na@hubersuhner.com
SINGAPORE
HUBER+SUHNER (Singapore) Pte Ltd
11 Chang Charn Road
#05-02 Shriro House
SG-Singapore 159640
Tel. +65 6573 5500
Fax +65 6473 5522
info.sg@hubersuhner.com
SwEDEN
HUBER+SUHNER AB
Knarrarnäsgatan 7
Box 1247
SE-164 28 Kista
Tel. +46 (0)8 447 5200
Fax +46 (0)8 447 5201
info.se@hubersuhner.com
UAE
HUBER+SUHNER
Middle East Trading LLC
Dubai Investments Park *
European Business Center, Office 156
N 25° 00’ 13.83’’/ E 55° 09’ 19.06’’
P.O.Box 75843
Dubai (United Arab Emirates)
Tel. +971 4 81 35 35 - 0
Fax +971 4 81 35 35 - 1
info.me@hubersuhner.com
Additional Catalogues
Fiber Optic Connectors
and Assemblies
Item no. 84101808
Distributed Antenna
Sytems
Item no. 84078171
Connectors and adapters
Cable assemblies
Connectors for harsh
environment
Equipment for serial production and measurement
RF connectors, cables,
assemblies, components
Antennas
Fiber management
systems
Fiber Optic Cables
Item no. 84019826
RF and Microwave Components
Edition 2010
RF and Microwave
Components
Item no. 84068668
Indoor cables
Universal cables
Outdoor cables
Special cables
Coaxial attenuators
Terminations
RF power splitters
Special products
Fiber Optic Cabling
Systems
Item no. 23029084
Lightning Protection
Item no. 23002023
Pre-terminated cabling
systems
MASTERLINE
SMARTLINE
Mobile cabling system
Lightning EMP protectors
NEMP protectors
Data line protectors
DC blocks
RF Coaxial Connectors
General Cataloque
Item no. 84019826
Micro miniature
connectors
Cable connectors
Subminiature connectors
Adaptors
WAIVER
It is exclusively in written agreements that we provide our
customers with warrants and representations as to the technical specifications and/or the fitness for any particular purpose. The facts and figures contained herein are carefully
compiled to the best of our knowledge, but they are intended
for general informational purposes only.
HUBER+SUHNER AG
Degersheimerstrasse 14
9100 Herisau
Switzerland
Tel. +41 71 353 4111
Fax +41 71 353 4444
info@hubersuhner.com
84126953/04.2011
HUBER+SUHNER is certified according to
ISO 9001, ISO 14001, ISO/TS 16949 and IRIS.
hubersuhner.com
Download