Valves Complete Connection Sets With Jaga Pro valves and Jaga valves Individual Valve Components With connection options Valve Technical Details Presettable valves and Pressure drop for both Jaga and Jaga Danfoss valves www.jaga.co.uk 65 Complete Connection Sets with Jaga Pro Valves Mini Freestanding, Heights 130mm, 230mm and 280mm Chrome/ White COLO.PF2.DC.3... Chrome COLO.PF2.JA.3... White COLO.PF2.JC.3... Silver Thermostatic head 4 COLO.PF2.DW.3... Jaga Pro valves 1 Code Connection to the floor 5 Sleeve couplings Mini Freestanding, All Heights Chrome/ White COLO.PF2.DC.2... Chrome COLO.PF2.JA.2... White COLO.PF2.JC.2... Silver Thermostatic valve 4 COLO.PF2.DW.2... Thermostatic head 5 1 Code Connection to the floor Sleeve couplings Straight lockshield Note: for heights 80mm and 130mm please use 100mm high fixed feet only to accomodate installation of straight lockshield valve. Head Types DW DC JA JC Chrome/ White Chrome White Silver For sleeve coupling details, see page 76-77. Complete ordering code with sleeve couplings according to the material used and diameter of the tube. 66 Complete Connection Sets with Jaga Valves Thermostatic valve COMC.JH2.MA.2... Manual COMC.JH2.DW.2... Chrome/ White COMC.JH2.JA.2... White COMC.JH2.RM.2... Remote controlled thermostatic head COMC.JH2.DS.2... Thermostatic head with sensor at distance Straight lockshield Sleeve couplings 4 Code Mini Canal, Depths 90mm and 110mm White Remote controlled thermostatic head Chrome/ White Thermostatic valve COMC.JV2.MA.2... Manual COMC.JV2.DW.2... Chrome/ White COMC.JV2.JA.2... White COMC.JV2.RM.2... Remote controlled thermostatic head COMC.JV2.DS.2... Thermostatic head with sensor at distance Thermostatic head with sensor at distance 4 Code Mini Canal, Depths 140mm and 190mm White Angled lockshield Chrome/ White Sleeve couplings Head Types MA DW JA RM DS Manual Chrome/ White White White Remote Head Chrome/ White Remote Sensor For sleeve coupling details, see page 76-77. Complete ordering code with sleeve couplings according to the material used and diameter of the tube. www.jaga.co.uk The details shown are part of a full and comprehensive range of valve and control components available. Please contact jaga@jaga.co.uk if you require any further information. 67 Complete Connection Sets with Jaga Valves Canal Compact and Canal Plus, All Depths Valve at the base of the duct - detachable heat exchanger Manual COCP.JF2.DW.2... Chrome/ White COCP.JF2.JA.2... White COCP.JF2.RM.2... Remote controlled thermostatic head COCP.JF2.DS.2... Thermostatic head with sensor at distance Example with thermostatic head and sensor at distance 4 Code Sleeve couplings COCP.JF2.MA.2... Flexible connections White Chrome/ White Connection details Thermostatic valve Window side Angled lockshield 190 Valve at the base of the duct - without detachable heat exchanger Connection details Window side 50 Thermostatic valve Thermostatic head with sensor at distance Angled lockshield Sleeve couplings 190 Head Types MA DW JA RM DS Manual Chrome/ White White White Remote Head Chrome/ White Remote Sensor For sleeve coupling details, see page 76-77. Complete ordering code with sleeve couplings according to the material used and diameter of the tube. 68 Complete Connection Sets with Jaga Valves Canal Plus Only, Standard Depths Valve at the top of the duct With TRV Head in the Duct Thermostatic head COCP.E60.MA.2... Manual COCP.E60.JA.2... White 4 Connection right Thermostatic valve Sleeve couplings COCP.E30.MA.2... Manual Straight lockshield COCP.E30.JA.2... White 4 Code Connection left Extended connection Remote controlled Connection right COCP.E60.RM.2... White Connection left COCP.E30.RM.2... Remote controlled thermostatic head White 50 Window side Connection details 190 Head Types MA Manual For sleeve coupling details, see page 76-77. Complete ordering code with sleeve couplings according to the material used and diameter of the tube. www.jaga.co.uk JA RM White White Remote Head 69 Individual Valve Components Jaga Pro valve Jaga Pro Valve Connection Options To the wall To the floor To the floor 1 2 4 5 4 3 5095.020 5095.020 Jaga, Jaga Type 6 and Jaga Danfoss Connection Options To the floor 5090.108 5090.109 8 Standard With extension pipe With 1 lockshield 1/2” 180° To the floor 5090.108 5090.109 11 5090.109 5090.109 With extension pipe and lockshield 1/2” 70 11 12 5090.108 5090.108 5090.108 5090.109 12 With extension pipe and 2 lockshields 1/2“ 180° Individual Valve Components Jaga Pro Valve 50 1/2" max 80 max 80 ø 39 51 use PFTE tape 4 ø 50 Dimensions The valve extends to 2 cm below the casing Code 5094.414 max 85 max 138 ø 52 38 1 M 24 6 5 Regulator screw (hex screw 6 mm). Position see pressure drop graph. max 90 --Specially shortened thermostatic valve in order to be fully concealed within the casing --With pre-setting at the flow, completely lockable (flow and return) --For connection to the floor --With screw thread M30 x 1.5 (Heimeier compatible) --With synthetic spindle protection for setting on site Elbow 90° M24 x M24 25 31 Code 5095.020 M 24 21 M 24 Pro key Code 5090.1120 Tool for easy mounting of the Jaga Pro valve For sleeve coupling details, see page 76-77. www.jaga.co.uk 71 Individual Valve Components Jaga Type 6 Valve M24 male thread, suited for shortened connection distance Dimensions 25 M24 30 max 80 max 105 max 135 ø 39 use PFTE tape Code 5090.407 24 ø 50 G 1/2" --Specially shortened thermostatic valve in order to be fully concealed within the casing --With pre-setting in 6 steps --With screw thread M30 x 1.5 (Heimeier compatible) --With synthetic spindle protection for setting on site --For connection to the floor 5 ø 52 1 max 85 max 90 Jaga Valve ½" BSP female thread, suited for shortened connection distance Dimensions max 80 max 105 max 135 ø 39 G 1/2" 25 30 ø 50 24 Code 5090.405 use PFTE tape 4 G 1/2" 72 ø 52 1 max 85 5 --Specially shortened thermostatic valve in order to be fully concealed within the casing --With pre-setting in 6 steps --With screw thread M30 x 1.5 (Heimeier compatible) --With synthetic spindle protection for setting on site --For connection to the floor max 90 Individual Valve Components Jaga Danfoss Valve For Jaga Danfoss thermostatic heads ø 56 24 G 1/2" 30 28 81 139 109 ø 45 use PFTE tape G 1/2" Code 5090.402 81 --Specially shortened thermostatic valve in order to be fully concealed within the casing --Integrated presettable water flow delimitation to control maximum amount of flowing water --With synthetic spindle protection for setting on site --For connection to the floor Jaga Connection Components Extension Pipe 1/2" 1/2" 51 51 1/2" 51 Code 5090.108 1/2" 1/2" 1/2" Lockshield ½" 180° 1/2" 1/2" 1/2" Code 5090.109 60 60 60 1/2" 1/2" Lockshield ½" 90° 1/2" 24 1/2" 1/2" 24 Code 5090.110 1/2" 1/2" 1/2" www.jaga.co.uk 30 1/2" 30 30 73 Individual Valve Components Thermostatic Heads for Jaga Valves Technical data --Liquid filled Jaga and Jaga Deco thermostatic head: setting deviation 0.5 ≤ XP=2K --Maximum water flow temperature: 110°C --Thermostatic head liquid filled with anti-freeze protection 6°C --Minimum and maximum temperature control (5°C-26°C) by ringsystem --Screw connection M30 x 1.5 Code Jaga thermostatic head 5090.1104 White 5090.1111 Chrome 5090.1110 Chrome / White 5090.1119 Silver White RAL 9010 White White --Thermostatic head liquid filled with anti-freeze protection 8°C --Minimum and maximum temperature control (10°C-27°C) by ringsystem --Screw connection M30 x 1.5 Code Deco thermostatic head Code 5090.110101 --Remote controlled TRV head for heating elements --Technical data as per Jaga thermostatic head above Code 5090.1106 --Remote sensing TRV head for heating elements --Sensor with 2m long capillary --Technical data as per Jaga Deco thermostatic head above Code Manual head 5090.1115 --Valve cap for manual on/off control Jaga remote controlled thermostatic head 74 Individual Valve Components Thermostatic Heads for Jaga Danfoss Valves Technical data --RA gas filled Jaga Danfoss thermostatic head and RAX liquid filled --Head: setting deviation 0.5 ≤ XP=2K --Maximum water flow temperature: 120°C Code Thermostatic head 5090.105 White RAL 9010 type RA 5090.10501 White type RAX 5090.10502 Chrome type RAX Thermostatic Head Type RA: --With click connection --Gas filled TRV (super fast reaction) --Anti-freeze protection 7.5°C --2 locking pins by which the TRV can be blocked or limited both at a minimum and maximum temperature (5°C-26°C) --Locking pin for theft prevention Thermostatic Head Type RAX: --With click connection --Liquid filled --Anti-freeze protection 8°C --Regulates from 8°C up to 30°C Code Remote controlled thermostatic head 5090.107 --Remote controlled TRV head for heating elements. --Remote sensor, wire and the setting knob are all liquid filled --Anti-freeze protection 7.5°C --Both the minimum and maximum temperature can be limited (6°C 8.5 28°C) --Length of capillary: 2m --Minimal interior diameter of the tube for conducting the capillary = 22mm White RAL 9010 Code Manual head 5090.102 White RAL 9010 --Valve cap for manual on/off control www.jaga.co.uk 75 Individual Valve Components 1/2” Sleeve Couplings M24 for Complete Connection Sets Only Just for tube 18/1 Just for tube 18/1 1/2” Just foJrutsutbfeor1t8u/b1e 18/1 1/2” 1/2” Just for tube 15/1 Just for tube 15/1 1/2” For flexible steel or copper tube 1/2” Tube Ø 110 10/1 112 12/1 114 14/1 115 15/1 116 16/1 118 18/1 1/2” 1/2” 1/2” 1/2” Just for tube 15/1 Code Just forJust tube for15/1 tube 15/1 Example COLO. PW2.DW. 32. (insert relevant code from below) Just for tube 18/1 Included in the price of the connection sets. Complete ordering code with sleeve couplings according to the material used and diameter of the 1/2” tube. (The correct type of sleeve coupling is determined by the ordering code of the connection set). 1/2” For synthetic tube Code Tube Ø 212 12/2 214 14/2 219 16/1.5 216 16/2 217 17/2 218 18/2 1/2” 1/2” 1/2” 1/2” 1/2” For RPE/ALU tube Code Tube Ø 314 14/2 316 16/2 326 16/2.2 318 18/2 1/2” 1/2” 1/2” Steel tube for C.H Code Tube Ø 501 1/2” 503 3/8” 1/2” 1/2” 1/2” 1/2” Short coupling for flexible steel tube or copper tube ø 15mm 1/2” Code Tube Ø 125 15/1 1/2” Eurocone flexible steel or copper 1/2” Code Tube Ø 112 12/1 114 14/1 115 15/1 116 16/1 118 18/1 1/2” 1/2” 1/2” Eurocone synthetic or RPE/ALU Code Tube Ø 612 12/2 614 14/2 616 16/2 617 17/2 618 18/2 615 15/2.5 619 16/1.5 620 20/2 ø denotes diameter. Complete ordering code with sleeve couplings according to the material used and diameter of the tube. 76 Individual Valve Components Sleeve Couplings for M24 - Jaga Pro and Jaga Type 6 For flexible steel or copper tube Code Description 5094.110 ø M24 x 10/1 5094.112 ø M24 x 12/1 5094.114 ø M24 x 14/1 5094.115 ø M24 x 15/1 5094.116 ø M24 x 16/1 5094.118 ø M24 x 18/1 For RPE/ALU tube Just for tube 18/1 M24 Just for tube 15/1 Code Description 5094.314 ø M24 x 14/2 5094.316 ø M24 x 16/2 5094.326 ø M24 x 16/2.2 5094.318 ø M24 x 18/2 M24 For synthetic tube Steel tube for C.H Code Description Code Description 5094.212 ø M24 x 12/2 5094.501 ø M24 x 1/2” 5094.214 ø M24 x 14/2 5094.503 ø M24 x 3/8” 5094.219 ø M24 x 16/1,5 5094.216 ø M24 x 16/2 5094.217 ø M24 x 17/2 5094.218 ø M24 x 18/2 M24 Description 5098.110 ø 1/2” x 10/1 5098.112 ø 1/2” x 12/1 5098.114 1/2” For RPE/ALU tube 1/2” Code Description 5098.314 ø 1/2” x 14/2 5098.316 ø 1/2” x 16/2 ø 1/2” x 14/1 5098.326 ø 1/2” x 16/2.2 5098.115 ø 1/2” x 15/1 5098.318 ø 1/2” x 18/2 5098.116 ø 1/2” x 16/1 5098.118 ø 1/2” x 18/1 Just for tube 18/1 1/2” 1/2” RPE tube = reticulated polyethylene tube with an intermediate aluminium layer. Just for tube 15/1 Steel tube for C.H For synthetic tube Code Description 5094.502 ø 1/2” x 1/2” 5094.504 ø 1/2” x 3/8” Code Description 5098.212 ø 1/2” x 12/2 5098.214 ø 1/2” x 14/2 5098.219 ø 1/2” x 16/1.5 5098.216 ø 1/2” x 16/2 5098.217 ø 1/2” x 17/2 Code Description ø 1/2” x 18/2 5098.015 ø 1/2” x 15/1 5098.218 M24 Sleeve Couplings for Jaga and Jaga Danfoss Valves For flexible steel or copper tube Code M24 1/2” 1/2” Short coupling for flexible steel tube or copper tube ø 15mm 1/2” ø denotes diameter. Complete ordering code with sleeve couplings according to the material used and diameter of the tube. www.jaga.co.uk 77 Valve Technical Details Presettable Valves Why a balancing thermostatic radiator valve? Due to the application of the specially designed Jaga and Jaga Danfoss presettable TRV’s, the water flow volume (Kv) in the heating elements can be adjusted precisely to ensure optimal performance of the TRV. A similar TRV with built-in balancing may be considered as having two control possibilities. The first option gives a variable control, determined by the required room temperature. The second option, through balancing offers control of the maximum water flow rate. Without Balancing TRV With Balancing TRV The above diagrams indicate the water distribution to heating elements at start-up. The system on the right has balanced TRV fitted, the one on the left does not. Benefits --When the water flow volume is controlled, the required volume of water is delivered to the various heating elements. This process saves energy and ensures maximum comfort. --At start-up, when all TRV’s are fully opened, the balancing control allows the heating elements furthest away to get the required amount of hot water. --The water flow temperature can be reduced earlier because every heating element warms up in a uniform manner, eliminating restrictive energy loss that can be caused by overheating incorrectly balanced elements. --The noise of excessive water flow will also be reduced thanks to the balancing flow control. --The optimal water distribution allows a smaller water circulation pump to be installed. --The water distribution to the different heating elements can easily be adapted when extending or changing the heating system. 78 Valve Technical Details Pressure Drop for Jaga Valve --Maximum water flow temperature: 120°C --Maximum pressure of system: 10 bar --Maximum pressure drop 0.6 bar complying to the noise standard ISO 3743 mWK mCE mWS mWC bar Pre-setting 1 2 3 4 5 6 KvS Kv: m3/h/ΔP=1 bar 0.1 0.2 0.3 0.4 0.5 0.6 0.8 2-pipe 1 2 3 4 5 6 Kvs kPa 1 100 8 0.8 80 6 5 0.6 0.5 60 50 4 0.4 40 3 0.3 10 30 Pressure drop 30 dB(A) 2 0.2 1.5 0.15 20 15 25 dB(A) 10 8 1.0 0.1 0.8 0.08 0.6 0.5 0.4 0.06 0.05 0.04 6 5 0.3 0.03 3 0.2 0.02 2 0.15 0.015 1.5 0.1 0.01 0.08 0.008 0.8 0.06 0.05 0.04 0.006 0.005 0.004 0.6 0.5 0.03 0.003 0.3 0.02 0.002 0.2 0.015 0.0015 0.15 0.01 0.001 4 1 Example Heat exchanger 1 kW (Table ΔT=50) ΔT = 10 °C (75 - 65 = 10°C) ΔP = 0.1 bar (to be setted over the valve) Pre-setting = 3 0.4 0.1 7 10 20 30 40 50 70 100 200 300 400 500 700 1000 Water flow in kg/h t=10°C 0.08 0.12 0.23 0.5 0.7 t=15°C 0.12 0.17 0.35 0.7 1 t=20°C 0.16 0.23 0.47 0.7 1 t=40°C 0.33 0.47 0.93 2 1 2 2 2 3 4 3 5 7 3 4 5 3 4 5 7 4 5 7 10 10 www.jaga.co.uk 20 7 10 Note kW 10 30 kW 20 kW 40 kW Details shown are for valves with standard Kv. Reduced Kv valves are available, please contact Jaga's technical department on 01531 631 533. 79 Valve Technical Details --Maximum water flow temperature: 120°C --Maximum pressure of system: 10 bar --Maximum pressure drop 0.6 bar complying to the noise standard ISO 3743 Pressure Drop for Jaga Danfoss Valve Pre-setting 1 Kv: m3 /h/ ΔP=1 bar 0.06 2 3 4 5 6 7 N NKvS Open 0.10 0.17 0.25 0.35 0.45 0.56 0.71 1 1.1 10 1 2 3 4 5 6 7 N 1-pipe kPa 1 100 8 0.8 80 6 5 0.6 0.5 60 50 4 0.4 40 3 0.3 2 Pressure drop bar Nkvs mWK mCE mWS mWC One pipe 2-pipe 30 30 dB(A) 20 0.2 15 25 dB(A) 1.5 0.15 1.0 0.1 0.8 0.08 0.6 0.5 0.4 0.06 0.05 0.04 6 5 0.3 0.03 3 0.2 0.02 2 0.15 0.015 1.5 0.1 0.01 0.08 0.008 0.8 0.06 0.05 0.04 0.006 0.005 0.004 0.6 0.5 0.03 0.003 0.3 0.02 0.002 0.2 0.015 0.0015 0.15 0.01 0.001 10 8 4 1 Example Heat exchanger 1 kW (Table ΔT=50) ΔT = 10°C (75 - 65 = 10°C) ΔP = 0.1 bar (to be set over the valve) Pre-setting = 4 0.4 0.1 7 10 20 30 40 50 70 100 200 300 400 500 700 1000 Water flow in kg/h 80 t=10°C 0.08 0.12 0.23 0.5 0.7 t=15°C 0.12 0.17 0.35 0.7 1 t=20°C 0.16 0.23 0.47 0.7 1 t=40°C 0.33 0.47 0.93 2 1 2 2 2 3 4 3 5 7 3 4 5 3 4 5 7 4 5 7 10 10 20 7 10 Note kW 10 30 kW 20 kW 40 kW Details shown are for valves with standard Kv. Reduced Kv valves are available, please contact Jaga's technical department on 01531 631 533.