TALGIL COMPUTING & CONTROL LTD. P.O.B. 775 Kiryat Motzkin 26119 Tel : 972-4-8775948 Fax : 972-4-8775949 E-mail : talgil33@netvision.net.il Digital Differential Pressure Sensor The digital differential pressure sensor DP measures the pressure difference between two points and when the difference exceeds a predefined set-point it reacts by closing a dry contact output. The unit is meant to be used with backwashing systems of automatic filters, it is highly accurate and low power consuming. The red LED – blinks during normal operation and blinks fast when the battery is low The green LEDis ON when the contact is closed JP4- LEDS active/ not active JP5- for laboratory use- DON’T TOUCH ! JP1- for laboratory use- DON’T TOUCH ! Manual test switch S1 – 4 dip witches for set point setting 12 volt DC or 24 volt AC Red command tube to the high pressure point Black command tube to low pressure point Dry contact output with no polarity for signaling external controller Starting Up The electronic board contains 4 dip-switches (S1) which serve for starting up the system and selecting the reaction set-point. When all the 4 switches are in OFF position (pointing down) the unit is not active. When there is at least one switch ON (pointing up) the unit is active. The active state is indicated by the blinking of the red LED, a short blink each 5 seconds. TALGIL COMPUTING & CONTROL LTD. P.O.B. 775 Kiryat Motzkin 26119 Tel : 972-4-8775948 Fax : 972-4-8775949 E-mail : talgil33@netvision.net.il Reaction set-point setting The state of the 4 dip-switches S1 defines the pressure difference at which the unit will react by closing its dry contact output, this point is known as the reaction set-point. As long as the pressure difference stays above the defined set point the contact remains closed. The following table shows the connection between the position of S1 and the pressure difference associated with each setting, Position No. S1 (1-ON ; 0-OFF) Reaction pressure difference 1 2 3 4 Atm. psi 00 0 0 0 0 01 1 0 0 0 0.1 2 02 0 1 0 0 0.3 4 03 1 1 0 0 0.4 6 04 0 0 1 0 0.5 8 05 1 0 1 0 0.7 10 06 0 1 1 0 0.8 12 07 1 1 1 0 1.0 14 08 0 0 0 1 1.1 16 09 1 0 0 1 1.2 18 10 0 1 0 1 1.4 20 11 1 1 0 1 1.5 22 12 0 0 1 1 1.6 24 13 1 0 1 1 1.8 26 14 0 1 1 1 1.9 28 15 1 1 1 1 2.0 30 The unit is not active The red LED indications The LED behavior The LED is OFF A short blink every 5 seconds 3 fast blinks every 5 seconds Indicated state The unit is not active Normal operation & battery level above 9.5 v Operating with low battery, less than 9 v TALGIL COMPUTING & CONTROL LTD. P.O.B. 775 Kiryat Motzkin 26119 Tel : 972-4-8775948 Fax : 972-4-8775949 E-mail : talgil33@netvision.net.il Testing the dry contact operation The electronic board contains a “test switch” that when pushed will cause the dry contact to be closed for 5 seconds. As usually, the closing of the contact will be indicated by lighting the green LED. Remarks It is necessary to use a filter between the high pressure point and the RED command tube to eliminate blocking the command tube by the unfiltered water. For energy saving purposes the pressure difference is checked every 15 seconds. Then 16 samples are taken continuously, the average of these samples is considered as the current pressure difference reading. For energy saving purposes the position of JP4 can be changed so that the middle pin will be connected to the upper pin (instead of to the lower pin). As a result of this, the LED indications will be stopped. The user is not permitted to touch any of the jumpers except for JP4 ! Any change in the position of the jumpers may disturb the operation of the unit. The correct jumpers setting is as shown in the picture above. When the battery voltage drops bellow 6.5 volts the dry contact is opened regardless of the pressure difference and the unit turns itself OFF. CONNECTION DIAGRAMM FILTRON 8 DC AND DP ELECTRONIC FILTRON 8 DC FP1801 CONNECTION BOARD (FILTRON 8 DC) LCD & keyboard plug BUZZER Sets LCD type DP Electronic DP0002 F 3.6 DC FILTRON 8 DC OUTPUTS 1 - 8 OUT 4 OUT 6 OUT 8 OUT 2 + O C + O C + O C + O C + G G BATT. + O C + O C + O C + O C OUT 1 OUT 3 OUT 5 OUT 7 INPUTS 1 - 8 IN 2 I C I C IN 1 IN 4 I C IN 6 I C I C IN 3 I C IN 5 IN 8 I C I C IN 7 Input 1 : differential pressurstat C O + + _ Battery 12V SOLENOID NO NC Black Red Red Black White White FOR INPUTS I - Input C - Common of inputs Input 2 : pressurstat Input 3 : water meter DP ELECTRONIC CARD White White Green Green Red Red Black Black Non polarity power connection CONNECTION DIAGRAMM FILTRON 246 AC AND DP ELECTRONIC FILTRON 246 - 2 AC FP2120 FILTRON 246 - 4AC FP2140 FILTRON 246 - 6 AC FP2160 CONNECTION BOARD (FILTRON 246 AC) O N 1 23 45 67 8 24 VAC c FUSE 2A OUT 1 c OUT 2 c OUT 3 c OUT 4 c OUT 5 c OUT 6 +- In G DIP SWITCH COUNTER NOT USED White SOLENOID 24V AC Green Red Black DP Electronic DP0002 TRANSFORMER 220V / 24V AC Black Red DP ELECTRONIC CARD Green White CONNECTION DIAGRAMM FILTRON 246 DC AND DP ELECTRONIC FILTRON 246 - 2 DC FP1140 FILTRON 246 - 4DC FP1140 FILTRON 246 - DAC FP1160 CONNECTION BOARD (FILTRON 246 DC) ON 1 23 45 6 7 8 + - BATT + O C + O C OUT 1 OUT 2 + O C + O OUT 3 OUT 4 C + O OUT 5 C + O OUT 6 + - C In G DIP SWITCH COUNTER NOT USED SOLENOID 12V DC LATCH Normally Closed Normally Open c Red Black White o Black Red Green + White White Black Red DP Electronic DP0002 Red Black BATTERY 12V DP ELECTRONIC CARD Non polarity power connection Green White