ADDENDA NO. 1 AUGUST 26, 2008 USPS FACILITY WINNETKA CARRIER ANNEX NORTHBROOK, ILLINOIS COMM. NO. 1597-104 WHEREAS THIS ADDENDA CONFLICTS WITH THE INFORMATION CONTAINED IN THE DRAWINGS AND/OR SPECIFICATIONS, THIS ADDENDA SHALL GOVERN. Drawings: S.1 – General Structural Notes. Amend the first paragraph, the first sentence, titled “Testing Laboratory Services” to read as follows: The Contractor shall employ….. Specifications: Delete Section 16510 – Interior Lighting and Section 16520 – Exterior Lighting dated 9/17/2007 and replace same with Section 16510 – Interior Lighting, pages 1 thru 17, and Section 16520 – Exterior Lighting, pages 1 thru 7, dated 2/12/2008. Specification Section 00010 – Table of Contents, revised and attached. Drawings: T1.1 – Title Sheet, Schedule of Drawings, Delete Drawings E1.0, E1.1, E1.2 and E1.4. Add Drawings E001, E101, E201 and E301 identified as Revision 1 and dated 9/5/2008. Drawings/ Specifications: A1.1 – The pre-engineered canopy shall be all inclusive including the required foundation system. Refer to attached Specification Section 13600 – Pre-Engineered Canopy. Specification: Refer to attached Spectification Section 09710 – Epoxy Flooring and Wall Coatings. WINNETKA CARRIER ANNEX NORTHBROOK, ILLINOIS USPS NO. J80967 COMM. NO. 1597-104 DOCUMENT 00010 - TABLE OF CONTENTS INTRODUCTORY INFORMATION Document Document Document Document 00001 00002 00007 00010 Project Title Page Project Directory Seals Page Table of Contents SCHEDULE, CLAUSES AND ATTACHMENTS, AND SOLICITATION REQUIREMENTS Issued separately by U.S. Postal Service. SPECIFICATIONS DIVISION 1 - GENERAL REQUIREMENTS Section Section Section Section Section Section Section Section Section Section Section Section Section Section 01110 Summary of Work 01110_A Summary of Work – Attachment A 01120 Contract Documents 01150 Environmental Procedures 01150_A Environmental Procedures – Attachment A 01150_B Environmental Procedures – Attachment B 01320 Construction Progress Documentation 01330 Submittal Procedures 01330f Schedule of Values 01450 Quality Control 01500 Temporary Facilities and Controls 01600 Product Requirements 01700 Execution Requirements 01780 Closeout Submittals and Training DIVISION 2 - SITEWORK Section Section Section Section Section Section Section Section Section Section Section Section Section Section Section Section Section Section 02220 02230 02300 02315 02370 02510 02530 02554 02630 02634 02743 02753 02765 02810 02917 02920 02930 02935 Site Demolition Site Clearing Earthwork Excavation and Fill Erosion and Sedimentation Control Water Distribution Sanitary Sewerage Gas Distribution Storm Drainage Storm Drainage Manholes Bituminous Concrete Pavement Plain Cement Concrete Pavement Pavement Markings Irrigation Systems Soil Preparation Lawns and Grasses Exterior Plants Plant Maintenance DIVISION 3 - CONCRETE Section Section Section 03100 03200 03300 Concrete Forms and Accessories Concrete Reinforcement Cast-In-Place Concrete 00010 - 1 USPS SSBD SPECIFICATION Issued Date: 9/17/2007 TABLE OF CONTENTS WINNETKA CARRIER ANNEX NORTHBROOK, ILLINOIS USPS NO. J80967 COMM. NO. 1597-104 DIVISION 4 - MASONRY Section Section Section 04100 04210 04220 Masonry Mortar and Grout Clay Unit Masonry Concrete Unit Masonry DIVISION 5 - METALS Section Section Section 05120 05500 05520 Structural Steel Metal Fabrications Handrails and Railings DIVISION 6 - WOOD AND PLASTICS Section Section Section Section 06100 06170 06175 06200 Rough Carpentry Wall Protection Wood Trusses Finish Carpentry DIVISION 7 - THERMAL AND MOISTURE PROTECTION Section Section Section Section Section Section 07190 07210 07310 07620 07840 07900 Water Repellents Building Insulation Shingles Sheet Metal Flashing and Trim Firestopping Joint Sealers DIVISION 8 - DOORS AND WINDOWS Section Section Section Section Section Section Section Section 08100 08210 08310 08360 08380 08410 08710 08800 Metal Doors and Frames Wood Doors Access Doors and Panels Sectional Overhead Doors Impact Traffic Doors Aluminum Windows, Entrances and Storefronts Door Hardware Glazing DIVISION 9 - FINISHES Section Section Section Section Section Section Section Section 09110 09250 09300 09510 09650 09680 09710 09900 Non-Load Bearing Wall Framing Gypsum Board Tile Acoustical Ceilings Resilient Flooring Carpet Epoxy Flooring and Wall Coatings Painting DIVISION 10 - SPECIALTIES Section Section Section Section Section Section Section Section Section 10125 10170 10200 10260 10350 10435 10436 10520 10810 Bulletin Boards Plastic Toilet Compartments Louvers and Vents Corner Guards Flagpoles Exterior Signage Miscellaneous Signage Fire Protection Specialties Toilet Accessories 00010 - 2 USPS SSBD SPECIFICATION Issued Date: 9/17/2007 TABLE OF CONTENTS WINNETKA CARRIER ANNEX NORTHBROOK, ILLINOIS USPS NO. J80967 COMM. NO. 1597-104 DIVISION 11 - EQUIPMENT Section 11160 Loading Dock Equipment DIVISION 12 - FURNISHINGS Section Section 12358 12490 Miscellaneous Casework Window Treatments DIVISION 13 - SPECIAL CONSTRUCTION Section Section Section Section 13600 13702 13851 13900 Pre-Engineered Canopy Intrusion Detection System Fire Alarm Fire Suppression DIVISION 14 - CONVEYING SYSTEMS Not Used. DIVISION 15 - MECHANICAL Section Section Section Section Section Section Section Section Section Section Section Section Section Section 15050 15080 15100 15410 15480 15736 15767 15769 15810 15830 15833 15850 15900 15950 Basic Mechanical Materials and Methods Mechanical Insulation Building Services Piping Plumbing Fixtures Water Heaters Split-System Air Conditioning Units Unit Heaters Electric Heating Ducts Ceiling Fans Centrifugal Fans Air Outlets and Inlets HVAC Instrumentation and Controls Testing, Adjusting, and Balancing DIVISION 16 - ELECTRICAL Section Section Section Section Section Section Section Section Section Section Section Section Section Appendix A 16050 16120 16130 16140 16210 16274 16410 16441 16510 16520 16582 16705 16720 Basic Electrical Materials and Methods Conductors and Cables Raceway and Boxes Wiring Devices Electrical Utility Services Power Transformers Enclosed Switches Panelboards Interior Luminaires Exterior Luminaires Lighting Controls Communications Cable and Equipment Intercommunication System Geotechnical Subsurface Investigation END OF DOCUMENT USPS SSBD Specifications issued: 9/17/2007 Last revised: 9/17/2007 00010 - 3 USPS SSBD SPECIFICATION Issued Date: 9/17/2007 TABLE OF CONTENTS WINNETKA CARRIER ANNEX NORTHBROOK, ILLINOIS USPS NO. J80967 COMM. NO. 1597-104 SECTION 09710 - EPOXY FLOORING AND WALL COATINGS A. SUMMARY 1. B. SUBMITTALS 1. 2. 3. C. Product Data: Required Samples: Required Color: Per USPS Non-Retail Standard Finishes schedule QUALITY ASSURANCE 1. 2. D. Epoxy flooring and wall coating in Toilet Rooms and Kitchens. Applicator to be certified and licensed by the flooring manufacturer. Field samples to be approved and serve as minimum acceptable standards for finished work. MANUFACTURERS 1. Stonhard: a. b. E. Floor Product: Stonclad GS Wall Product: Stonglaze VSC 2. Crossfield Products, Dex-O-Tex 3. General Polymers 4. Florock 5. Dur-A-Flex Inc. INSTALLATION 1. Apply coating systems in accordance with manufacturer instructions for material and substrate involved. 2. Provide ample ventilation during application. END OF SECTION USPS Major Facilities Master Outline Specification issued: 1/17/2007 Last revised: 3/22/2007 09710 - 1 USPS MMOS Issued Date: 1/17/2007 EPOXY FLOORING AND WALL COATINGS WINNETKA CARRIER ANNEX NORTHBROOK, ILLINOIS USPS NO. J80967 COMM. NO. 1597-104 SECTION 13600 – PRE-ENGINEERED CANOPY PART 1 - GENERAL 1.1 SUMMARY A. Section includes prefabricated steel or aluminum canopies. B. ADA-ABA Accessibility Guidelines: U.S. Architectural & Transportation Barriers Compliance Board's "Americans with Disabilities Act (ADA) Accessibility Guidelines for Buildings and Facilities; Architectural Barriers Act (ABA) Accessibility Guidelines." 1.2 A. PERFORMANCE REQUIREMENTS Structural Performance: Canopy shall withstand the effects of gravity loads and the following loads and stresses within limits and under conditions indicated according to ASCE/SEI 7: 1. 2. B. Thermal Movements: Allow for thermal movements from ambient and surface temperature changes. Base calculations on surface temperatures of materials due to both solar heat gain and nighttime-sky heat loss. 1. 1.3 Snow Loads: 25 psf. Wind Loads: 20 psf. Temperature Change (Range): 120 deg F (67 deg C), ambient; 180 deg F (100 deg C), material surfaces. SUBMITTALS A. Product Data: For each type of product indicated. Include construction details, material descriptions, dimensions of individual components and profiles, and finishes for canopy. B. Shop Drawings: For canopy. Include plans, elevations, sections, details, and attachments to other work. C. Samples for Initial Selection: For canopy with factory-applied color finishes. D. Samples for Verification: For exposed finishes, in manufacturer's standard sizes. E. Delegated-Design Submittal: Canopy indicated to comply with performance requirements and design criteria, including analysis data signed and sealed by the qualified professional engineer responsible for their preparation. F. Welding certificates. G. Maintenance Data. H. Warranty: Sample of special warranty. 1.4 A. QUALITY ASSURANCE Welding Qualifications: Qualify procedures and personnel according to the following: 1. 2. AWS D1.1/D1.1M, "Structural Welding Code - Steel." AWS D1.2/D1.2M, "Structural Welding Code - Aluminum." PRE-ENGINEERED CANOPY 13600 - 1 WINNETKA CARRIER ANNEX NORTHBROOK, ILLINOIS 3. B. 1.5 A. 1.6 A. USPS NO. J80967 COMM. NO. 1597-104 AWS D1.3, "Structural Welding Code - Sheet Steel." Regulatory Requirements: Comply with applicable provisions in the International Building Code 2006 Edition. COORDINATION Coordinate installation of anchorages. Furnish setting drawings, templates, and directions for installing anchorages, including sleeves, concrete inserts, anchor bolts, and items with integral anchors that are to be embedded in concrete or masonry. Deliver such items to Project site in time for installation. WARRANTY Special Warranty: Manufacturer's standard form in which manufacturer agrees to repair finish that fail in materials or workmanship within specified warranty period. 1. Warranty Period: Five years from date of Substantial Completion. PART 2 - PRODUCTS 2.1 A. MATERIALS Aluminum: Alloy and temper recommended by aluminum producer and manufacturer for type of use and finish indicated, and as follows: 1. 2. 3. Sheet: ASTM B 209 (ASTM B 209M). Extruded Shapes: ASTM B 221 (ASTM B 221M). Rolled Tread Plate: ASTM B 632/B 632M, Alloy 6061-T4 or Alloy 6061-T6. B. Zinc-Coated (Galvanized) Steel Sheet: ASTM A 653/A 653M, commercial quality, G90 (Z275) coating designation; mill phosphatized. C. Galvanized, Rolled Steel Tread Plate: ASTM A 786/A 786M, rolled from steel plate complying with ASTM A 572/A 572M, Grade 55 (380); hot-dip galvanized according to ASTM A 123/A 123M. D. Steel Structural Tubing: ASTM A 500, Grade B. E. Steel Plates, Shapes, and Bars: ASTM A 36/A 36M. F. Steel Mechanical Tubing: ASTM A 513, welded steel mechanical tubing. G. Zinc-Coated (Galvanized) Steel: Hot-dip galvanized according to ASTM A 123/A 123M. H. Anchorages: Anchor bolts; hot-dip galvanized according to ASTM A 153/A 153M or ASTM F 2329. 2.2 A. PREFABRICATED CANOPYS, GENERAL General: Provide a complete, integrated set of mutually dependent components that form a completely assembled, prefabricated canopy, ready for installation on Project site. 1. Building Style: As indicated on Drawings. PRE-ENGINEERED CANOPY 13600 - 2 WINNETKA CARRIER ANNEX NORTHBROOK, ILLINOIS 2.3 USPS NO. J80967 COMM. NO. 1597-104 GENERAL FINISH REQUIREMENTS A. Comply with NAAMM's "Metal Finishes Manual for Architectural and Metal Products" for recommendations for applying and designating finishes. B. Appearance of Finished Work: Noticeable variations in same piece are not acceptable. Variations in appearance of adjoining components are acceptable if they are within the range of approved Samples and are assembled or installed to minimize contrast. 2.4 A. FINISHES Steel and Galvanized-Steel Factory Finish: Immediately after cleaning and pretreating, apply manufacturer's standard two-coat, baked-on finish consisting of prime coat and thermosetting topcoat. 1. 2.5 A. Color and Gloss: As selected by Architect from manufacturer's full range. ALUMINUM FINISHES Color Anodic Finish: AAMA 611, AA-M12C22A42/A44, Class I, 0.018 mm or thicker. 1. Color: As selected by Architect from full range of industry colors and color densities. PART 3 - EXECUTION 3.1 EXAMINATION A. Examine substrates, areas, and conditions, with Installer present, for compliance with requirements for installation tolerances and other conditions affecting performance of the Work. B. Prepare written report, endorsed by Installer, listing conditions detrimental to performance of the Work. C. Proceed with installation only after unsatisfactory conditions have been corrected. END OF SECTION 13600 PRE-ENGINEERED CANOPY 13600 - 3 WINNETKA CARRIER ANNEX NORTHBROOK, ILLINOIS USPS NO. J80967 COMM. NO. 1597-104 SECTION 16510 - INTERIOR LIGHTING PART 1 - GENERAL 1.1 A. SUMMARY Section Includes: 1. 2. 3. 4. 5. 6. Interior luminaires and accessories. Emergency lighting units. Exit signs. Ballasts. Lamps. Luminaire accessories. B. Related Documents: The Contract Documents, as defined in Section 01110 - Summary of Work, apply to the Work of this Section. Additional requirements and information necessary to complete the Work of this Section may be found in other Documents. C. Related Sections: 1. 1.2 A. B. REFERENCES American National Standards Institute (ANSI): 1. ANSI C78.379 - Electric Lamps - Incandescent and High-Intensity Discharge Reflector Lamps - Classification of Beam Patterns. 2. ANSI C82.1 - Ballasts for Fluorescent Lamps - Specifications. 3. ANSI C82.4 - Ballasts for High-Intensity Discharge and Low Pressure Sodium Lamps (Multiple Supply Type). National Electrical Manufacturers Association (NEMA): 1. C. A. NEMA WD 6 - Wiring Devices-Dimensional Requirements. National Fire Protection Association (NFPA): 1. 2. 1.3 Section 16050 - Basic Electrical Materials and Methods: Basic electrical methods. NFPA 70 - National Electrical Code. NFPA 101 - Life Safety Code. SUBMITTALS Section 01330 - Submittals Procedures: Procedures for submittals. 1. Product Data: Provide dimensions, ratings, and performance data for each fixture specified. 2. Assurance/Control Submittals: 16510-1 USPS INTERIOR LIGHTING SPECIFICATION Issued Date: 2/12/2008 INTERIOR LIGHTING WINNETKA CARRIER ANNEX NORTHBROOK, ILLINOIS a. B. Manufacturer's Instructions: Indicate application conditions and limitations of use stipulated by Product testing agency. Include instructions for storage, handling, protection, examination, preparation, and installation of Product. Section 01780 - Closeout Submittals: Procedures for closeout submittals: 1. 1.4 USPS NO. J80967 COMM. NO. 1597-104 Operation and Maintenance Data: Submit manufacturer's operation and maintenance instructions for each type of fixture. QUALITY ASSURANCE A. Manufacturer Qualifications: Company specializing in manufacturing the Products specified in this section with minimum five years documented experience. B. Regulatory Requirements: 1. 2. 3. 1.5 Conform to requirements of NFPA 70. Conform to requirements of NFPA 101. Products: Listed and classified by Underwriters Laboratories Incorporated as suitable for the purpose specified and indicated. MAINTENANCE A. Section 01780 - Closeout Submittals: Procedures for closeout submittals. B. Extra Products: At completion of installation, deliver to Contracting Officer. 1. 2. Two of each plastic lens type. Each ballast type: Provide quantity equal to 10 percent of fixture total, but not less than two of each type. PART 2 - PRODUCTS 2.1 A. LUMINAIRE MANUFACTURERS Subject to compliance with project requirements, manufacturers offering Products which may be incorporated in the Work include the following: 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. Cooper Lighting (Halo, Invue, Lumark, McGraw-Edison, Metalux, Sure-Lites), Peachtree City, GA (770)486-4800. Cooper Crouse-Hinds, Syracuse, NY (315) 477-5531. Hubbell Lighting, Inc., (Columbia, Spaulding, Sterner) Spartanburg, SC (864) 599-6000. Indy Lighting, Fishers, IN (317) 849-1233. Kurt Versen Company, Westwood, NJ (201) 664-8200. Lightolier, Fall River, MA (508) 679-8131. Lithonia Lighting, Conyers, GA (770) 922-9000. Omega Lighting, Tupelo, MS (800) 234-1890. Phoenix Products Company, Inc., Milwaukee, WI (800) 973-3300. Prescolite Lighting, Spartanburg, SC (864) 599-6000. Day-Brite, Tupelo, MS (662) 842-7212. Holophane, Newark, OH (740) 345-9631. D.L. Manufacturing, North Syracuse, NY (315) 463-7348. Chloride Systems, Burgaw, NC (910) 259-1000. Day-O-Lite Manufacturing, Warwick, RI (401) 467-8232. Dual-Lite, Cheshire, CT (203) 699-2000. 16510-2 USPS INTERIOR LIGHTING SPECIFICATION Issued Date: 2/12/2008 INTERIOR LIGHTING WINNETKA CARRIER ANNEX NORTHBROOK, ILLINOIS 17. 18. 19. 20. 21. 22. 23. 24. 25. 26. 27. 28. 29. 30. 31. 32. 33. 34. 35. 36. 37. 38. 39. 40. B. 4. 5. 6. 7. 8. Description: Recessed, 2’W x 4’L x 4”D gasketed fluorescent grid troffer with acrylic lens. Lens: Prismatic acrylic, A-12 pattern, 0.125 inches thick. Housing:Cold rolled steel body, door is aluminum with mitered corners. Frame and housing finished with baked white enamel. Ballast: Two lamp electronic ballast. Mounting: Recessed in Inverted T suspended ceiling. Voltage: [277] [120]. Lamps: Two F32T8/SP41/IS/WM/ECO Alternate Manufacturers: a. Columbia 4PS24-232G-RAA12 E U b. Metalux 2GCRA-232A125 UNV EB8 Type A2Lithonia 2SP8-F-232RW-A12125 [277][120].GEB10IS: 1. 2. 3. 4. 5. 6. 7. 8. D. Edison-Price Lighting, Long Island City, NY (718) 685-0700. Gardco Lighting, San Leandro, CA (800) 227-0758. Gotham Lighting, Conyrs, GA (800) 315-4982. Guth Lighting, St. Louis, MO (314) 533-3200. H.E.Williams, Carthage, MO (417) 358-4065. Kenall Manufacturing, Gurnee, IL (847) 360-8200. Lumux Lighting, Los Angeles, CA (877) 895-5552. Pheonix Products, Milwaukee, WI (414) 438-1200. Selux Corporation, Highland, NY (845) 691-7723. LightAlarms (Thomas & Betts) Montreal, ON (888) 552-6467. Belfer Group, Farmingdale, NJ (732) 493-2666. Zumtobel Staff, Highland, NY (800) 448-4131. Kirlin Lighting, Detroit, MI (313) 259-6400. Kramer Lighting, Sturtevant, WI (800) 236-6800. Canlet Oak Lawn, IL (800) 441 1771 AEI, Meza,AZ (480)-733-6594 Optimum , Henderson,NC (800)541-9082 Lighting Alternatives, Cherry Hill, NJ (877)847-1102 Fostoria, Fostoria,OH (800)495-4525 Infinity, Carthage,MO (417)-359-3333 Widelite, San Marcos,TX (512)392-5821 GE Lighting Systems, Charlotte,NC (803)462-2016 Vista Simi Valley,CA, (805)527-0987 Nite-Brites, Tupelo,MS (800)234-1890 Type A1Lithonia 2WRT-G-232-A12125[277][120].GEB10IS: 1. 2. 3. C. USPS NO. J80967 COMM. NO. 1597-104 Description: Recessed, 2’W x 4’L x 4”D fluorescent flanged troffer with acrylic lens. Lens: Prismatic acrylic, A-12 pattern, 0.125 inches thick. Housing: Cold rolled steel body, door is aluminum with mitered corners. Frame and housing finished with baked white enamel. Ballast: Two lamp electronic ballast. Mounting: Recessed in a GWB ceiling. Voltage: [277] [120]. Lamps: Two F32T8/SP41/IS/WM/ECO Alternate Manufacturers: a. Columbia 4PS24-232F-RAA12125 EU b. Metalux 2FRAC-232A125 UNV EB8 Type A3Lithonia 2SP8-G-332RW-A12125 [277][120]. ].GEB10IS: 16510-3 USPS INTERIOR LIGHTING SPECIFICATION Issued Date: 2/12/2008 INTERIOR LIGHTING WINNETKA CARRIER ANNEX NORTHBROOK, ILLINOIS 1. 2. 3. 4. 5. 6. 7. 8. E. 4. 5. 6. 7. 8. 9. Description: Recessed, 2’W x 4’L x 4”D fluorescent grid troffer with acrylic lens. Lens: Prismatic acrylic, A-12 pattern, 0.125 inches thick. Housing: Cold rolled steel body, door is aluminum with mitered corners. Frame and housing finished with baked white enamel. Ballast: Four lamp electronic ballast. Mounting: Recessed in Inverted T suspended ceiling. Voltage: [277] [120]. Lamps: Four F32T8/SP41/IS/WM/ECO Alternate Manufacturers: a. Columbia 4PS24-432G-RAA12125 EU b. Metalux 2GRAC-432A125 UNV EB8 Switching: See electrical drawings for dual level workroom lighting requirements. Type A7Lithonia 2PM3N-G-A-232-16LS MVOLT GEB10 IS: 1. 2. 3. 4. 5. 6. 7. 8. G. Description: Recessed, 2’W x 4’L x 4”D fluorescent grid troffer with acrylic lens. Lens: Prismatic acrylic, A-12 pattern, 0.125 inches thick. Housing: Cold rolled steel body, door is aluminum with mitered corners. Frame and housing finished with baked white enamel. Ballast: Three lamp electronic ballast. Mounting: Recessed in Inverted T suspended ceiling. Voltage: [277] [120]. Lamps: Three F32T8/SP41/IS/WM/ECO Alternate Manufacturers: a. Columbia 4PS24-332G-RAA12.125 3EU b. Metalux 2GRAC-332A125 UNV EB8 Type A5Lithonia 2SP8- G-432RW-A12.125 [277] [120]. ].GEB10 IS: 1. 2. 3. F. USPS NO. J80967 COMM. NO. 1597-104 Description: Recessed, 2’W x 4’L x 6”D fluorescent parabolic troffer for grid ceiling. Louver: 3” deep low iridescent, vertical grain anodized aluminum precision parabolic louvers. 2 by 8 cells. Housing: die-formed prime cold-rolled steel, with contoured ballast/wireway cover. Ballast: Two lamp electronic ballast. Mounting: Recessed in Inverted T suspended ceiling. Voltage: [277] [120]. Lamps: Two F F32T8/SP41/IS/WM/ECO Alternate Manufacturers: a. Columbia P4D24-232G-LS28- E U b. MetaLux 2EP3GAX232S28I UNV EB8 Type B1Lithonia DMS-2-32-AR [277] [120].GEB10 IS: 1. 2. 3. 4. 5. 6. 7. 8. Description: Enclosed and gasketed industrial fluorescent fixture. UL listed for damp location. Lens: High impact acrylic diffuser. Housing: Steel housing Ballast: Two lamp electronic ballast. Mounting: Surface. Voltage: [277] [120]. Lamps: Two F32T8/SP41/IS/WM/ECO Alternate Manufacturers: a. Columbia LU4-232-E-DMR (Aluminum housing) b. Pheonix LFS232A (Aluminum housing) 16510-4 USPS INTERIOR LIGHTING SPECIFICATION Issued Date: 2/12/2008 INTERIOR LIGHTING WINNETKA CARRIER ANNEX NORTHBROOK, ILLINOIS H. Type CL1Lithonia C232-WGCSMR[277][120] GEB10 IS: 1. 2. 3. 4. 5. 6. 7. 8. I. Description; 4'-0" long, dual row, two fluorescent lamp strip luminaire with protective wire mesh with reflector around lamps. Lens: None Housing: Die-formed cold rolled steel housing with punched knockouts for mounting. End plates shall be die-formed heavy gauge rolled steel with punched knockouts for through wiring. White baked enamel with a minimum 85 percent reflectance. Ballast: Two lamp electronic ballast. Mounting: Surface mounted to the underside of the ceiling. Attach luminaire to ceiling grid by means of a gripper hanger which attaches to any standard ceiling grid system. For spaces without ceiling, suspend from structure with all-thread rods to required height. Electrical Contractor to determine quantity of hangers required for either method. Voltage: [277] [120]. Lamps: Two F32T8/SP41/IS/WM/ECO Alternate Manufacturers: a. Columbia CS4-232 EU-CSWG4-CSR4 b. Metalux SS-232-232I/GRP-SS-U-WG/SS-4FT-EB8 Type CV1Lithonia S132-GEB10 IS[277][120]: 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. J. USPS NO. J80967 COMM. NO. 1597-104 Description: Cove mounted; single lamp 4 feet long fluorescent strip luminaire. Louver: Lay-in chrome parabolic cube louver for illuminated cove, manufactured by American Louver Company, Skokie, Illinois (800) 323-4250, or approved substitution. Cell size- 1 1/2 inch x 1 1/2 inch x 1 inch. Width and Length - Refer to plans. Louver to be shipped to the site and installed with the protective film. Once the final inspection has been conducted the film is to be removed. Housing: Die-formed cold rolled steel with a painted exterior surface. Interlocked housing corners with positive locking and rigid construction. Housing to be finished in white baked enamel finish with a minimum reflectivity of 85 percent. Ballast: One or two lamp electronic ballast. Ballast to operate this fixture and an adjacent CV2 fixture where applicable. Note:Individual lead lengths shall not exceed 18 feet. Mounting: Surface mounted to the underside of the cove on a 2 inch spacer. Louver lays into constructed cove on wall angles (furnished and installed by general contractor). Louver shall be made into lengths and configurations shown on plans and fill the cove end to end. Voltage: [277] [120]. Lamp: F32T8/SP41/IS/WM/ECO Alternate Manufacturers: a. Metalux SN-132-UNV EB81 b. Columbia CS4-132-E U Type CV2Lithonia S117 [277] [120]GEB10 IS: 1. 2. 3. 4. Description: Cove mounted; single lamp 2 feet long fluorescent strip luminaire. Louver: Lay-in chrome parabolic cube louver for illuminated cove, manufactured by American Louver Company, Skokie, Illinois (800) 323-4250, or approved substitution paracube II. Cell size- 1 1/2 inch x 1 1/2 inch x 1 inch. Width and Length - Refer to plans. Louver to be shipped to the site and installed with the protective film. Once the final inspection has been conducted the film is to be removed. Housing: Die-formed cold rolled steel with a painted exterior surface. Interlocked housing corners with positive locking and rigid construction. Housing to be finished in white baked enamel finish with a minimum reflectivity of 85 percent. 16510-5 USPS INTERIOR LIGHTING SPECIFICATION Issued Date: 2/12/2008 INTERIOR LIGHTING WINNETKA CARRIER ANNEX NORTHBROOK, ILLINOIS 5. 6. 7. 8. 9. 10. K. 3. 4. 5. 6. 7. 8. 9. 10. 11. Description: Cove mounted; single lamp 3 feet long fluorescent strip fixture. Louver: Lay-in chrome parabolic cube louver for illuminated cove, manufactured by American Louver Company, Skokie, Illinois (800) 323-4250, or approved substitution paracude II. Cell size- 1 1/2 inch x 1 1/2 inch x 1 inch. Width and Length - Refer to plans. Louver to be shipped to the site and installed with the protective film. Once the final inspection has been conducted the film is to be removed. Housing: Die-formed cold rolled steel with a painted exterior surface. Interlocked housing corners with positive locking and rigid construction. Housing to be finished in white baked enamel finish with a minimum reflectivity of 85 percent. Ballast: One or two lamp electronic ballast. Ballast to operate this fixture and an adjacent CV2 fixture where applicable. Note: Individual lead lengths shall not exceed 18 feet. Mounting: Surface mounted to the underside of the cove on a 2 inch spacer. Louver lays into constructed cove on wall angles (furnished and installed by general contractor). Louver shall be made into lengths and configurations shown on plans and fill the cove end to end. Voltage: [277] [120]. Lamp: F25T8/SP41/ECO Alternate Manufacturers: a. Columbia CS3-125-E U b. Metalux SN-125-EB8-(T1LW) Type EM1Lithonia ELSQMN-LEX/ELA-FRK : 1. 2. 3. 4. 5. 6. 7. M. Ballast: This unit shall come complete, less ballast. Electrical contractor shall wire the lamp sockets to an adjacent CV1 or CV3 fixture. Mounting: Surface mounted to the underside of the cove on a 2 inch spacer. Louver lays into constructed cove on wall angles (furnished and installed by general contractor). Louver shall be made into lengths and configurations shown on plans and fill the cove end to end. Voltage: [277] [120]. Lamp: F17T8/SP41/ECO Alternate Manufacturers: a. Columbia CS2-117-E U b. Metalux SN-117-EB8 Type CV3Lithonia S125 [277] [120].GEB10 IS: 1. 2. L. USPS NO. J80967 COMM. NO. 1597-104 Description: Recessed 10.5 inch square decorative Nickel-Cadmium battery type emergency light unit. Provide with line latching, solid-state voltage limiting charger, solidstate switching, low voltage disconnect, brownout circuit, overload, short-circuit protection test switch and power indicator light. Lens: Lexan lens. Housing: Black thermoplastic body, UL924 listed, all components meet the UL 94-0.5VA flame retardant standard. Mounting: Provide with manufacturer rough-in kit for fully recessed installation. Voltage: [277] [120] Lamps: 10W Tungsten Halogen (included) Alternate Manufacturers: a. Chloride SPU30M-FR-PC (Polycarbonate Lens, 9” Square) b. Sure-Lites P4C7-PCL-FRK1/29-40 (9” Square) Type EM2Lithonia ELM627-B-N: 16510-6 USPS INTERIOR LIGHTING SPECIFICATION Issued Date: 2/12/2008 INTERIOR LIGHTING WINNETKA CARRIER ANNEX NORTHBROOK, ILLINOIS 1. 2. 3. 4. 5. 6. 7. N. 2. 3. 4. 5. 6. 7. Description: Industrial design emergency lighting unit with adjustable heads. Provide with line latching, solid-state voltage limiting charger, solid-state switching, low voltage disconnect, brownout circuit, overload, short-circuit protection test switch and power indicator light. Battery: Sealed, maintenance free Nickel-Cadmium, 6 volt, with 24 Watt capacity. Housing: 18-guage steel housing finished in instrument tan color, with hinged faceplate for ease of maintenance. UL924 listed, all components meet the UL 94-0.5VA flame retardant standard. Mounting: Wall mounted. Voltage: [277] [120]. Lamps: 8W Halogen (included) Alternate Manufacturers: a. Chloride CCL675DY2A-V (8W Sealed Par36 heads)) b. Dual-lite LM30N-V(7.2W halogen lamps) Type EM4(interior & exterior)Lithonia INDX12100W-ULT-H1212: 1. 2. 3. 4. 5. 6. 7. 8. P. Description: Compact contemporary design emergency lighting unit with adjustable heads. Provide with line latching, solid-state voltage limiting charger, solid-state switching, low voltage disconnect, brownout circuit, overload, short-circuit protection test switch and power indicator light. Battery: Sealed, maintenance free Nickel-Cadmium, 6 volt, with 27 Watt capacity. Housing: Black thermoplastic body, UL924 listed, all components meet the UL 94-0.5VA flame retardant standard. Mounting: Wall mounted. Voltage: [277] [120] Lamps: 9W krypton. (included) Alternate Manufacturers: a. Chloride S50N-T9-B-AM (50Watt cap., 9W Tungsten lamps) b. Dual-lite LZB20N (20Watt Cap., 5W halogen lamps) Type EM3Lithonia ELT24-N-AM-VM-H: 1. O. USPS NO. J80967 COMM. NO. 1597-104 Description: Surface Mounted UL wet location (NEMA 4X) listed emergency lighting unit Lamping: Sealed Beam PAR 36 Housing: Heavy-duty polycarbonate sealed, gasketed, and corrosion resisitant. Battery: Lead-Calcium, with self-diagnostics. Listed for cold weather (-40 degrees to 55 degrees C), damp and wet locations. Mounting: Surface wall. Voltage: Dual-voltage input capability (120/277). Lamps: Two 12W, 12V par36 composite halogen Alternate Manufacturers: a. Chloride: SV16L-W-HR (5.5W MR16 Lamps) b. Sure-Lites: UEL1WHSDAV (12W MR16 Lamps) Type MH1Kirlin HRR-08072/ED-17/MED100-43-40 [277][120]: 1. 2. 3. 4. 5. 6. Description: Recess mounted 8” aperture wet location downlight with horizontal lamp, tempered prismatic lens, regressed white door. Reflector: Upper reflector is highly reflective. Housing: Entire housing serviceable through removable trim assembly. Ballast: Constant wattage autotransformer encased and potted for qquiet operation. Voltage: [277] [120] Lamps: MP100/U/MED 16510-7 USPS INTERIOR LIGHTING SPECIFICATION Issued Date: 2/12/2008 INTERIOR LIGHTING WINNETKA CARRIER ANNEX NORTHBROOK, ILLINOIS 7. Q. 2. 3. 4. 5. 6. 7. 8. Description: Surface Mounted 18” diameter half cylinder wall mounted full cut-off luminaire with 12V emergency lighting. Lens door is fully gasketed with one-piece solid silicone. Reflector: Segmented reflector with wide throw optics. Housing: Die-cast single piece aluminum housing with 1/8” thick tempered glass lens. Ballast: Constant wattage autotransformer encased and potted for quiet operation. Mounting: Surface wall. Voltage: [277] [120] Lamps:MP100/U/MED & 100Q/CL/DC Alternate Manufacturers: a. Gardco: 104EMWT100MHBRP-FQ12v B84CG EMERGENCY b. Lumark: MH-IPC-100W-F-EM/SC/12V Type P1Phoenix DL-INC-IR-GG1: 1. 2. 3. 4. 5. 6. 7. T. Description: Surface mounted 17.5” square luminaire, overall height of 11.25” Housing: Die cast aluminum mounted directly to outlet box. Lens: Drop Polycarbonate refractor providing a square distribution. Ballast: Constant wattage autotransformer encased and potted for quiet operation. Voltage: [277] [120] Lamps: MP150/U/MED Alternative Manufacturers: a. Nite Brites DSS150MEPDPM-BLACK (25” SQ, 10” D) b. Lumark MHCL150BLK (21” SQ, 12” D) Type MH3LithoniaWSR100MWT (120)(277)-DC2012: 1. S. Alternative Manufacturers: a. Gotham LGHZ100M8RWT73 b. Kramer KL8100MHLHPLWSPYWFF Type MH2(interior)Lithonia KACM150MDPPDBL [277][120]: 1. 2. 3. 4. 5. 6. 7. R. USPS NO. J80967 COMM. NO. 1597-104 Description: Ceiling Mounted Dock Light with spring suspension swivel mounting, provide light head with glare guard and timer control switch. Light Head: Incandescent/Halogen. Housing: Fixture head of 18 gauge steel. Mounting: Swivel hanger for direct mounting to standard 4 inch junction box. Pendant to be 1/2 inch conduit with flexible spring for impact resistance and sufficient length to suspend center of light at 8’-6” AFF. Voltage: 120. Lamps: CF23EL/PAR38/BL/2/12 Sylvania Alternate Manufacturers: a. Fostoria DKL-25-FLX + INC + GS-1 Type PL1(interior & exterior) Infinity MHRL 13 175 ED28/MOG-H0RZ-FF: 1. 2. 3. 4. 5. 6. 7. Description: 12” Diameter Recessed shallow plenum, regressed lensed Metal Halide downlight compatible with metal slat ceiling systems. White smooth splay with prismatic lens. Reflector: Low brightness clear specular alzak finish reflector. Housing: Diecast aluminum lamp holder assembly. Ballast: Encased and potted constant wattage auto-transformer type, high power factor. Mounting: Mounting pan assembly with adjustable brackets. Voltage: [277] [120]. Lamps: M175/C/U. 16510-8 USPS INTERIOR LIGHTING SPECIFICATION Issued Date: 2/12/2008 INTERIOR LIGHTING WINNETKA CARRIER ANNEX NORTHBROOK, ILLINOIS 8. U. 4. 5. 6. 7. 8. Description: Pendant 10 inch diameter aperture compact fluorescent downlight. Reflector: Low brightness clear specular alzak finish reflector. Housing: Heavy gauge aluminum cylinder, finished white. Pendant hung on a 24” stem with a swivel canopy. Ballast: Two type 1, Class P, high power factor universal voltage electronic compact fluorescent ballasts, 1 or 2 lamp operation. Mounting: Pendant mounted, height as indicated by architectural elevations. Voltage: [277] [120]. Lamps: 3 – F32TBX/SPX35/A/4P Alternate Manufacturers: a. Infinity PHC13/12-PM Type R1 Gotham AF2/26DTT-8AR-[MVOLT]GEB10: 1. 2. 3. 4. 5. 6. 7. 8. 9. W. Alternate Manufacturers: a. KIRLIN HRR-11073-ED28-MOG175-43-40 b. Kramer KL11175MHLWSPYWFF (11”) Type PL2 Omega OM103H32PLTPCSPLPL-U (Univ:120/277): 1. 2. 3. V. USPS NO. J80967 COMM. NO. 1597-104 Description: Recessed compact fluorescent downlight with a nominal 8 1/4 inch diameter reflector opening. Baffle: specular clear alzak cone. Ballast: Type 1, Class P, high power factor universal voltage electronic compact fluorescent ballast Mounting Frame: Frame to be 16 gauge galvanized steel ring. Mounting ring shall be secured to grid ceiling bar hangers (supplied with fixture). NOTE: Luminaire frame to be supported from the structure by at least two opposing corners. Junction Box: Junction box to be code approved for through wiring. Junction box to be secured to the mounting ring and accessible from two sides. Junction box to be pre-wired and accessible per code through the ceiling trim opening. Mounting: 24 inch grid ceiling bar hangers shall be supplied by manufacturer and securely fastened to grid or 28 inch 'C' channel mounting bars for drywall ceilings. Voltage: [277] [120]. Lamp(s): Two (2) NEMA CFQ26W/G24d/835. Alternate Manufacturers: a. Kramer Lighting KL82X-26QPL-CFF b. Zumtobel/Staff S5D8204-U-8203RC Type R2 Gotham AFW2/26DTT-8AR MVOLT GEB10. 1. 2. 3. 4. 5. 6. 7. Description: Recessed compact fluorescent wallwasher. Baffle: Specular clear alzak cone. Ballast: Type 1, Class P, high power factor universal voltage electronic compact fluorescent ballast Mounting Frame: Frame to be 16 gauge galvanized steel ring. Mounting ring shall be secured to ceiling bar hangers (supplied with fixture). NOTE: Luminaire frame to be supported from the structure by at least two opposing corners. Junction Box: Junction box to be code approved for through wiring. Junction box to be secured to the mounting ring and accessible from two sides. Junction box to be pre-wired and accessible per code through the ceiling trim opening. Mounting: 24 inch grid ceiling bar hangers shall be supplied by manufacturer and securely fastened to grid or 28 inch "C" channel mounting bars for drywall ceiling. Voltage: [277] [120]. 16510-9 USPS INTERIOR LIGHTING SPECIFICATION Issued Date: 2/12/2008 INTERIOR LIGHTING WINNETKA CARRIER ANNEX NORTHBROOK, ILLINOIS 8. 9. X. 3. 4. 5. 6. 7. 8. Description: Recessed 2 feet x 2 feet, two lamp, nine cell parabolic fluorescent troffer. Louver: Post-anodized, highly specular, 3” deep, 9 cell parabolic louver constructed of high purity aluminum. Louver shall have a smooth, crack free, brilliant surface without iridescence. Louver shall be held by internal spring catches and center itself in the housing when it is snapped-in. Housing: Die-formed 20 gauge sheet with a baked white acrylic enamel finish. Housing shall be prepared in a three step process of cleaning, degreasing and washing prior to painting. Ballast: two lamp electronic ballast. Mounting: Recessed in Inverted T suspended ceiling. Voltage: [277] [120]. Lamps: Two FB032/841XP/6/SS/ECO Alternate Manufacturers: a. Metalux 2EP3GX-2U6T8S33MI-EB81 b. Columbia P4D22-232U6G-LS33-S-EB8LH Type R4 Lithonia 2PM3X33218LDGEB10RS: 1. 2. 3. 4. 5. 6. 7. 8. Z. Lamp(s): Two (2) CFQ26W/G24d/835. Alternate Manufacturers: a. Kramer Lighting KL82X-26QPLWW-CFF b. Zumtobel/Staff S5D8204-U-8203WC Type R3 Lithonia Lighting 2PM3NGB2U3169LS MVOLT GEB10RS 1. 2. Y. USPS NO. J80967 COMM. NO. 1597-104 Description: Surface mounted 2 feet x 4 feet, three lamp, eighteen cell parabolic fluorescent troffer. Louver: Post-anodized, highly specular eighteen cell parabolic louver constructed of high purity aluminum. Louver shall have a smooth, crack free, brilliant surface without iridescence. Louver shall be held by internal spring catches and center itself in the housing when it is snapped-in. Housing: Die-formed 20 gauge sheet with a baked white acrylic enamel finish. Housing shall be prepared in a three step process of cleaning, degreasing and washing prior to painting. Ballast: Three lamp electronic ballast. Mounting: Surface to ceiling. Voltage: [277] [120]. Lamps: F32T8/SP41/IS/WM/ECO Alternate Manufacturers: a. Metalux 2EP3GX-332S36MI-277-ER81 b. Columbia P4D24-332G-LS36-S-3E Type R5 Lithonia 2SP-GB232-A12125-GEB10RS. 1. 2. 3. 4. 5. 6. 7. 8. Description: Recessed 2 feet x 4 feet, two lamp, lensed troffer. Louver: clear prismatic acrylic lens, 0.125 inch thick. Housing: Die-formed 20 gauge sheet with a baked white acrylic enamel finish. Housing shall be prepared in a three step process of cleaning, degreasing and washing prior to painting. Ballast: two lamp electronic ballast. Mounting: Recessed in Inverted T suspended ceiling. Voltage: [277] [120]. Lamps: Two F32T8/SP41/IS/WM/ECO Alternate Manufacturers: 16510-10 USPS INTERIOR LIGHTING SPECIFICATION Issued Date: 2/12/2008 INTERIOR LIGHTING WINNETKA CARRIER ANNEX NORTHBROOK, ILLINOIS a. b. AA. Metalux 2GC232-A125ER81 Columbia 4PS24-232-G-FS-A12125-EP Type R6 Lithonia 2SP-G-432-A12125-GEB10RS. 1. 2. 3. 4. 5. 6. 7. 8. BB. USPS NO. J80967 COMM. NO. 1597-104 Description: Recessed 2 feet x 4 feet, four lamp, lensed troffer. Louver: clear prismatic acrylic lens. Housing: Die-formed 20 gauge sheet with a baked white acrylic enamel finish. Housing shall be prepared in a three step process of cleaning, degreasing and washing prior to painting. Ballast: two lamp electronic ballasts. Mounting: Recessed in Inverted T suspended ceiling. Voltage: [277] [120]. Lamps: F32T8/SP41/IS/WM/ECO Alternate Manufacturers: a. Metalux 2GC432-A125ER8 b. Columbia 4PS24-432-G-FS-A12125EB Type SP5(exterior) Lithonia KSF1175M R2 SF DBB [277] [208]: 1. 2. 3. 4. 5. 6. 7. 8. Description: Rectilinear architectural arm-mounted full cut-off. Reflector: Anodized segmented reflectors. Type II distribution. Housing: Rugged aluminum rectilinear housing with all seams continuously welded for integrity. Corrosion-resistant polyester powder coat Ballast: Constant wattage auto-transformer type, high power factor. Mounting: 12 – 15’ Square straight aluminum pole. Voltage: [277] [208]. Lamps: M175/C/U. Alternate Manufacturers: a. McGraw Edison CAL175MHMT2SF BZ b. Hubbell RCS-A-H17-H3-F-Q-DBW4 CC. Type T3: 1. Track: Lytespan 6001NWH. 2. 3. Fixture: Lightolier 8279ENWH. Description: 4 feet long single circuit track with recessed feed-end connector and t-bar attachment clips. Features: White track light wall wash fixture. Mounting: T-bar ceiling clip. Voltage: 120. Lamps: (2) FT40W/DL/2G11/RS/835. Alternate Manufacturers: a. Prescolite AKTHLCE240WH and ArchiTrak. 4. 5. 6. 7. 8. DD. Type UC1 Lithonia N2S-17-120-TW2: 1. 2. 3. 4. 5. Description: Under cabinet mounted 2 feet long, single fluorescent lamp luminaire, with solid front. Housing: Die formed cold rolled steel. Lens: Clear acrylic prismatic serrated diffuser shall snap into place without tools. Finish: White polyester powder coat, 92 % overall reflectance. Ballast: This unit shall come complete, less ballast. Electrical contractor shall wire the lamp sockets to an adjacent UC 2 fixture. 16510-11 USPS INTERIOR LIGHTING SPECIFICATION Issued Date: 2/12/2008 INTERIOR LIGHTING WINNETKA CARRIER ANNEX NORTHBROOK, ILLINOIS 6. 7. 8. EE. 2. 3. 4. 5. 6. 7. 8. Description: Under cabinet mounted 3'-0" long, single fluorescent lamp luminaire, with solid front Housing: Die formed cold rolled steel. Lens: Clear acrylic prismatic serrated diffuser shall snap into place without tools. Finish: White polyester powder coat, 92 % overall reflectance. Ballast: One Magnetek Triad OCTIC T8, one or two lamp ballast. Ballast to operate this fixture and an adjacent UC 1 fixture where applicable. Individual lead lengths shall not exceed 18 feet. Voltage: 120. Lamp: F25T8/XL/SP41/ECO Alternate Manufacturers: a. H.E.Williams 2SF-24-125-2Lamp ballast-120 b. Belfer 6316-FO25-1-2Lamp ballast Type W1 Lithonia TAF10332-Mvolt-GEB10IS-DLAF ME: 1. 2. 3. 4. 5. 6. 7. 8. GG. Voltage: 120. Lamp: F17T8/XL/SP41/ECO Alternate Manufacturers: a. H.E.Williams 2SF-24-117-Tandem-120 b. Belfer 6316-FO17-1-T8/41K Tandem Type UC2 Lithonia N2S-25-120-TW2: 1. FF. USPS NO. J80967 COMM. NO. 1597-104 Description: Pendant mounted, 8 feet long, fluorescent industrial fixture providing 10 percent uplighting. Louver: Aluminum cross louver provides 30 degree shielding both crosswise and lengthwise. Finished in white polyester acrylic paint. Housing: Channel and end plates of formed steel. Reflector of one piece steel strengthened by formed apertures, embossed ribs and upturned edge beads. Slots in reflector provide 10 percent uplighting with 11o crosswise shielding from formed reflector. Finished with 88 percent minimum reflectance polyester acrylic paint. Ballast: 2-3 lamp electronic ballasts. Mounting: Steel pipe pendant (5/8” diameter) and canopy. Voltage: [277] [120]. Lamps: Six (6) F32T8/SP41/IS/WM/ECO Alternate Manufacturers: a. Columbia IC-8-332-3E ICVWCB b. H.E.Williams 82-8-632-EB3 – LOUVER Type W2 Lithonia AF10332-Mvolt-GEB10IS-DLAF ME: 1. 2. 3. 4. 5. 6. 7. Description: Pendant mounted, 4 feet long, fluorescent industrial fixture providing 10 percent uplighting. Louver: Aluminum cross louver provides 30 degree shielding both crosswise and lengthwise. Finished in white polyester acrylic paint. Housing: Channel and end plates of formed steel. Reflector of one piece steel strengthened by formed apertures, embossed ribs and upturned edge beads. Slots in reflector provide 10 to15 percent uplighting with 11o crosswise shielding from formed reflector. Finished with 88 percent minimum reflectance polyester acrylic paint. Ballast: 3 lamp electronic ballast. Mounting: Steel pipe pendant stem (5/8 inch diameter) and canopy. Voltage: [277] [120] Lamps: Three (3) F32T8/SP41/IS/WM/ECO 16510-12 USPS INTERIOR LIGHTING SPECIFICATION Issued Date: 2/12/2008 INTERIOR LIGHTING WINNETKA CARRIER ANNEX NORTHBROOK, ILLINOIS 8. USPS NO. J80967 COMM. NO. 1597-104 Alternate Manufacturers: a. Columbia IC-4-332-3E ICVWCB b. H.E.Williams 82-4-332-EB3 – LOUVER HH. Type W3 Holophane HBT4DSNNNO46-EP-2: 1. 2. 3. 4. 5. 6. II. Type W6 LIGHTING ALTERNATIVES FWHB24/T8848-RFW-MB4-WG-FH-2X432T8PSUNV: 1. 2. 3. 4. 5. 6. 7. 8. JJ. Description: Pendant mounted industrial fluorescent high bay with wide beam distribution and (2) programmed start ballasts with a ballast factor of at least 0.88. Features: Single stem pendant mount, wire guard. Housing: Cold rolled steel painted before fabrication with 92% reflectance white reflector. Mounting: Ceiling, 20’ and above. Voltage: [277] [120] Lamps: Eight (8) F32T8/SP41/IS/WM/ECO Warranty for combination Lamp and ballast systems shall be utilized, similar to Quick 60+ by Sylvania for a system consisting of Quicktronic PSX T8 ballast with Octron XP lamps. Alternate Manufacturers: a. OPTIMUM LIGHTING G21832UV2PSWPSWG b. AEI LIGHTING T8CLS 832 UNI41 PSWH SP Type XF1Canlet 68-02-01-0G-11: 1. 2. 3. 4. 5. 6. 7. KK. Description: Pendant mounted industrial fluorescent high bay with wide beam distribution and (2) programmed start T8 ballasts for 2-level switching. Housing: Cold rolled steel painted before fabrication with 92% reflectance white reflector. Mounting: Ceiling, above 15’ and below 20’ Voltage: [277] [120] Lamps: Six (6) F32T8/SP41/IS/WM/ECO Alternate Manufacturers: a. Lighting Alternatives FWHB24/T8/6/48/RFW/FH/ 2/2X332T8/IS INV b. Day-Brite FBF632T8-2/3EBH-U Description: Vaportight incandescent listed and labeled for Class I, Div. 2, Groups C,D, hazardous locations in accordance with article 501 of the National Electrical Code. Lens: Heat and impact resistant glass globe. Housing: Body and guard of lexan polycarbonate. Mounting: Surface ceiling mounted. Voltage: 120 Lamps: 135W/A19/130V Alternate Manufacturer: a. Hubbell NVX15GHG Type X1Sure-Lites CCX-71-70-R-WH-SD : 1. 2. 3. 4. 5. 6. 7. Description: Ceiling mount, single face exit sign with canopy. Features: Red Letters, White Stencil, White Housing (verify colors with local jurisdiction). Injection molded UL94-5V rated polycarbonate frame and canopy. Mounting: Ceiling or end-mount. Battery: Maintenance free sealed Nickel Cadmium with long life, full recharge time of 24 hours max. Voltage: 120. Lamps: LED lamp module. Alternate Manufacturers: 16510-13 USPS INTERIOR LIGHTING SPECIFICATION Issued Date: 2/12/2008 INTERIOR LIGHTING WINNETKA CARRIER ANNEX NORTHBROOK, ILLINOIS a. b. LL. USPS NO. J80967 COMM. NO. 1597-104 Chloride SLN1RW-AD Lightalarms XQ-U-ELR-D Type X2Sure-Lites CCX-72-70-R-WH-SD : 1. 2. 3. 4. 5. 6. Description: Ceiling mount, double face exit sign with canopy. Features: Red Letters, White Stencil, White Housing (verify colors with local jurisdiction). Injection molded UL94-5V rated polycarbonate frame and canopy. Two bottom apertures snap out to emit downlight as required. Mounting: Ceiling or end-mount. Voltage: 120. Lamps: LED lamp module. Alternate Manufacturers: a. Chloride SLN2RW-AD b. Lightalarms XQ-U-ELR-D MM. Type CI02Vista AGVSP-LED-DC-HL-C-ZN-WT-UNV-MW: 1. 2. 3. 4. 5. 6. 7. 8. 2.2 A. Description: Recessed 9.25”w x 3.3”h x 4.3”d step light with L.E.D. source Features: Die cast aluminum step light with louver face. Housing: Back box constructed of die-cast aluminum alloy. Louvers: Die-cast aluminum alloy. Mounting: Recessed wall mounting. Voltage: Universal (both120 & 277) Lamp: White LED’s included Alternate Manufacturers: a. Kenall MSLS)DBCPWLL [120] [277] (9.25”w x 3.75”h x 3.5”d) b. Lumux SL630/LED/BRONZE [120] [277] (10.25”w x 4”h x 3.25”d) ok ELECTRONIC FLUORESCENT LAMP BALLASTS Manufacturers: 1. 2. 3. 4. 5. Advance Transformer Company, Rosemont, IL (847) 390-5000. Motorola, Lake Zurich, IL (800) 654-0089. Universal Lighting Technologies, Nashville, TN (615) 316-5100. Osram/Sylvania, Danvers, MA (800) 544-4828. Hatch Transformers, Tampa, FL (813)288-8006 B. Description: High frequency, energy efficient, electronic fluorescent lamp ballasts operating lamps at a frequency above 42 kHz with power factor of 0.98 for primary lamp. Ballast shall be compatible for operating the lamps indicated. Ballast shall have a minimum ballast factor for primary lamp of 0.85. Ballast shall provide independent lamp operation for instant start allowing remaining lamp(s) to maintain full light output when one or more lamps fail. The lamp crest factor shall measure 1.7 or less. Ballasts shall have a minimum "Ballast Factor" of 0.87. Ballasts shall meet or exceed all EMI and RFI standards of the Federal Communications Commission (FCC) regulations Part 18 (including 15J). Ballasts shall be UL labeled and comply with all local, State and Federal efficiency standards. C. Compact fluorescent ballasts shall be high efficiency, energy efficient, electronic ballasts operating at a frequency above 50 kHz with a power factor of 0.99. Total harmonic distortion shall range fro 5 to 13%, depending upon lamp/ballast combination. Compact fluorescent ballasts shall operate 10 to 32 Watt lamps, either two lamp ballasts, or a single lamp ballast (in three lamp fixtures). Ballasts shall be factory tested and meet ANSI 15 C62.41, ANSI C82.1 Class P. 16510-14 USPS INTERIOR LIGHTING SPECIFICATION Issued Date: 2/12/2008 INTERIOR LIGHTING WINNETKA CARRIER ANNEX NORTHBROOK, ILLINOIS D. 2.3 A. Voltage 120 and 277 volts to match luminaire voltage. HIGH INTENSITY DISCHARGE (HID) BALLASTS Manufacturers: 1. 2. 3. 4. 5. B. C. 2.4 A. USPS NO. J80967 COMM. NO. 1597-104 Advance Transformer Company, Rosemont, IL (847) 390-5000. General Electric Company, Nela Park, OH (800) 435-2677. Universal Lighting Technologies, Nashville, TN (615) 316-5100. Osram/Sylvania, Danvers, MA (800) 544-4828. Robertson, Blue Island, IL (800) 323-5633 Description: 1. Metal Halide Electronic Ballast for lamps up to 100 Watt: Power factor of .98 to 1.0, ballast factor of 1.0, capable of powering two, 400, 350 or 320 watt standard or pulse start lamps with integral color coded leads. Multi-voltage capable and shall operate from a nominal voltage range of 208 – 277 volts AC. System efficiency of greater than 93% under full lamp operation and FCC compliant for EMI/RFI as per parts 18.305 and 18.307. Total harmonic distortion of less than 5%. Lamp wattage shall not vary more than 0.5% for a 10% change in input line voltage. A crest factor of 1.5 shall not be exceeded. Where applicable a means of continuous dimming shall be part of the ballast system. Dimming control is to be of common 0 – 10 volt DC, two wire IEC protocol. Dimming shall range from 100% down to no less than 50% of input power. Ballast assembly shall be UL listed for damp locations, 40 degrees C, and comply with all local, state and federal efficiency standards. 2. Ballast for Metal-Halide Lamps 175 – 400 Watt: Comply with ANSI C82.4 and UL 1029. Constant-wattage autotransformer or regulating high-power-factor type, with a minimum starting temperature of Minus 30 deg C for single-lamp ballasts, and a normal operation temperature of 40 degrees C. Open-circuit operation of ballast shall not reduce average life. To prevent ballast noise, Manufacturers' standard epoxy-encapsulated models, which are designed to minimize audible fixture noise shall be utilized. Voltage: Match luminaire voltage. LAMPS Incandescent, Fluorescent and High Intensity Discharge (HID) Lamp Manufacturers: 1. 2. 3. General Electric Company, Nela Park, OH (800) 435-2677. Osram/Sylvania, Danvers, MA (800) 544-4828. Philips Lighting Company, Somerset, NJ (800) 555-0050. B. Lamp Types: As specified for luminaire. Refer to Section 01600 for substitutions and product options. C. Reflector Lamp Beam Patterns: ANSI C78.379. D. Four foot long T8 and U-bend T8 linear fluorescent lamps shall have a mercury content of less than 20 ppm. E. Linear fluorescent, compact fluorescent and incandescent amps must pass the federal Toxic Characteristic Leaching Procedure (TCLP) test and be classified non-hazardous waste. 16510-15 USPS INTERIOR LIGHTING SPECIFICATION Issued Date: 2/12/2008 INTERIOR LIGHTING WINNETKA CARRIER ANNEX NORTHBROOK, ILLINOIS USPS NO. J80967 COMM. NO. 1597-104 PART 3 - EXECUTION 3.1 EXAMINATION A. Section 01700 - Execution Requirements: Verification of existing conditions before starting work. B. Verification of Conditions: Verify that field measurements, surfaces, substrates and conditions are as required, and ready to receive Work. C. Report in writing to Contracting Officer prevailing conditions that will adversely affect satisfactory execution of the Work of this Section. Do not proceed with Work until unsatisfactory conditions have been corrected. D. By beginning Work, Contractor accepts conditions and assumes responsibility for correcting unsuitable conditions encountered at no additional cost to the United States Postal Service. 3.2 INSTALLATION A. Install suspended luminaires and exit luminaire signs using pendants supported from swivel hangers or in accordance with details shown on drawings. Provide pendant length required to suspend luminaire at indicated height. B. Support recessed fluorescent fixtures 2 foot x 2 foot and larger using a minimum of four wire hangers of same gauge as ceiling suspension system supported from building structure independent of ceiling framing. C. Locate recessed ceiling luminaires as indicated on reflected ceiling plan. D. Install surface mounted luminaires and exit luminaire signs plumb and adjust to align with building lines and with each other. Secure to prevent movement. Mount exit signs to outlet box mounted flush in wall or ceilings. Outlet box for ceiling mounted exit signs: Connect to rigid conduit system. E. Exposed Grid Ceilings: Support surface mounted luminaires on grid ceiling directly from building structure. F. Install recessed luminaires to permit removal from below. G. Install recessed luminaires using accessories and firestopping materials to meet regulatory requirements for fire rating. In fire rated ceilings recessed luminaires must carry 1 hour UL fire rating classification. H. Install earthquake clips to secure recessed grid-supported luminaires in place. I. Install a minimum of four independent wire hangers, one on each corner supported from building structure. J. Install wall mounted luminaires, emergency lighting units and exit luminaire signs at height as scheduled. K. Install accessories furnished with each luminaire. L. Connect luminaires, emergency lighting units and exit luminaire signs to separate branch circuits using minimum 1/2 inch (12 mm) flexible metal conduit whips maximum 5 feet in length. 16510-16 USPS INTERIOR LIGHTING SPECIFICATION Issued Date: 2/12/2008 INTERIOR LIGHTING WINNETKA CARRIER ANNEX NORTHBROOK, ILLINOIS USPS NO. J80967 COMM. NO. 1597-104 M. Bond products and metal accessories to branch circuit equipment grounding conductor. N. Install specified lamps in each emergency lighting unit, exit luminaire sign, and luminaire. 3.3 FIELD QUALITY CONTROL A. Section 01450 - Quality Control: Field testing and inspection. B. Operate each luminaire after installation and connection. Inspect for proper connection and operation. 3.4 ADJUSTING A. Aim and adjust luminaires as directed by Contracting Officer. B. Position exit luminaire sign directional arrows as indicated. 3.5 CLEANING A. Section 01700 - Execution Requirements: Cleaning installed work. B. Clean electrical parts to remove conductive and deleterious materials. C. Remove dirt and debris from enclosures. D. Clean photometric control surfaces as recommended by manufacturer. E. Clean finishes and touch up damage. F. Relamp fixtures with defective or burned out lamps just prior to Final Acceptance. END OF SECTION 16510-17 USPS INTERIOR LIGHTING SPECIFICATION Issued Date: 2/12/2008 INTERIOR LIGHTING WINNETKA CARRIER ANNEX NORTHBROOK, ILLINOIS USPS NO. J80967 COMM. NO. 1597-104 SECTION 16520 - EXTERIOR LIGHTING PART 1 - GENERAL 1.1 A. SUMMARY Section Includes: 1. 2. Exterior luminaires and accessories. Poles. B. Related Documents: The Contract Documents, as defined in Section 01110 - Summary of Work, apply to the Work of this Section. Additional requirements and information necessary to complete the Work of this Section may be found in other Documents. C. Related Sections: 1. 2. 1.2 A. B. REFERENCES American National Standards Institute (ANSI): 1. ANSI C78.379 - Electric Lamps - Incandescent and High-Intensity Discharge Reflector Lamps - Classification of Beam Patterns. 2. ANSI C82.4 - Ballasts for High-Intensity-Discharge and Low Pressure Sodium Lamps (Multiple-Supply Type). Illuminating Engineering Society (IES): 1. 2. C. A. IES RP-8 - Recommended Practice for Roadway Lighting. IES RP-20 - Lighting for Parking Facilities. National Fire Protection Association (NFPA): 1. 1.3 Section 03300 - Cast-in-Place Concrete: Concrete for pole foundation. Section 16050 - Basic Electrical Materials and Methods: Basic electrical methods. NFPA 70 - National Electrical Code. SUBMITTALS Section 01330 - Submittal Procedures: Procedures for submittals. 1. Product Data: a. b. 2. Fixture dimensions, ratings, and performance data. Complete computer data printout of illumination levels based on a grid system of multiples of spacing to pole height. Shop Drawings: a. Indicate dimensions and components for each luminaire which is not a standard Product of the manufacturer. 16520-1 USPS EXTERIOR LIGHTING SPECIFICATION Issued Date: 2/12/2008 EXTERIOR LIGHTING b. 1.4 A. QUALITY ASSURANCE Qualifications: 1. B. A. Manufacturer: Company specializing in manufacturing the Products specified in this section with minimum five years documented experience. Regulatory requirements: 1. 2. 1.5 Indicate illumination levels in accordance with layout and scheduled luminaires indicated on Drawings. Conform to requirements of NFPA 70. Products: Listed and classified by Underwriters Laboratories, Inc. as suitable for the purpose specified and indicated. DELIVERY, STORAGE, AND HANDLING Section 01600 - Material and Equipment: Transport, handle, store, and protect products. PART 2 - PRODUCTS 2.1 A. LUMINAIRE MANUFACTURERS Subject to compliance with project requirements, manufacturers offering Products which may be incorporated in the Work include the following: 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 2.2 A. Cooper Lighting (Halo, Invue, Lumark, McGraw-Edison, Metalux, Sure-Lites), Peachtree City, GA (770)486-4800. Cooper Crouse-Hinds, Syracuse, NY (315) 477-5531. Hubbell Lighting, Inc., (Columbia, Spaulding, Sterner) Spartanburg, SC (864) 599-6000. Lightolier, Fall River, MA (508) 679-8131. Lithonia Lighting, Conyers, GA (770) 922-9000. Holophane, Newark, OH (740) 345-9631. Gardco Lighting, San Leandro, CA (800) 227-0758. Gotham Lighting, Conyrs, GA (800) 315-4982. Guth Lighting, St. Louis, MO (314) 533-3200. LSI Industries, Inc, Cincinnati, OH (513) 793-3200. Pheonix Products, Milwaukee, WI (414) 438-1200. Selux Corporation, Highland, NY (845) 691-7723. FIXTURE TYPES Type EM4(interior & exterior)Lithonia INDX12100W-ULT-H1212: 1. 2. 3. 4. 5. 6. 7. 8. Description: Surface Mounted UL wet location (NEMA 4X) listed emergency lighting unit Lamping: Sealed Beam PAR 36 Housing: Heavy-duty polycarbonate sealed, gasketed, and corrosion resisitant. Battery: Lead-Calcium, with self-diagnostics. Listed for cold weather (-40 degrees to 55 degrees C), damp and wet locations. Mounting: Surface wall. Voltage: Dual-voltage input capability (120/277). Lamps: Two 12W, 12V par36 composite halogen Alternate Manufacturers: a. Chloride: SV16L-W-HR (5.5W MR16 Lamps) b. Sure-Lites: UEL1WHSDAV (12W MR16 Lamps) 16520-2 USPS MASTER SPECIFICATION Issue Date: 9/17/2005 EXTERIOR LIGHTING WINNETKA CARRIER ANNEX NORTHBROOK, ILLINOIS B. Type MH2(Exterior)LithoniaWSR100MWT(120)(277)SF: 1. 2. 3. 4. 5. 6. 7. 8. C. 2. 3. 4. 5. 6. 7. 8. Description: 12” Diameter Recessed shallow plenum, regressed lensed Metal Halide downlight compatible with metal slat ceiling systems. White smooth splay with prismatic lens. Reflector: Low brightness clear specular alzak finish reflector. Housing: Diecast aluminum lamp holder assembly. Ballast: Encased and potted constant wattage auto-transformer type, high power factor. Mounting: Mounting pan assembly with adjustable brackets. Voltage: [277] [120]. Lamps: M175/C/U. Alternate Manufacturers: a. KIRLIN HRR-11073-ED28-MOG175-43-40 b. Kramer KL11175MHLWSPYWFF (11”) Type SB1(exterior) Lithonia KBA650MR5TBDDB SF: 1. 2. 3. 4. 5. 6. 7. 8. E. Description: Surface Mounted 18” diameter half cylinder wall mounted full cut-off luminaire. Lens door is fully gasketed with one-piece solid silicone. Reflector: Segmented reflector with wide throw optics. Housing: Die-cast single piece aluminum housing with 1/8” thick tempered glass lens. Ballast: Constant wattage autotransformer encased and potted for quiet operation. Mounting: Surface wall. Voltage: [277] [120] Lamps:MP100/U/MED Alternate Manufacturers: a. Gardco: 104WT100MHBRPF b. Lumark: MH-IP-C-100W-F1 Type PL1(interior & exterior) Infinity MHRL 13 175 ED28/MOG-H0RZ-FF: 1. D. USPS NO. J80967 COMM. NO. 1597-104 Description: 36“ High extruded one piece aluminum domed top round bollard with flared cone. Reflector: Anodized aluminum upper reflector with spun anodized aluminum flared cone Housing: extruded, one piece aluminum, 0.156” wall thickness. Top cover is a weldment of 0.125” wall extrusion and 0.25” top plate. Top seals to housing with closed cell EPDM gasketing. Ballast: Pulse start electronic, high power factor. Mounting: Four ½” x 11” anchor bolts with double nuts and washers, 4-1/2” bolt circle included. Voltage: [120] [277] Lamps: MH50W/E17 Alternate Manufacturers: a. McGraw-Edison BRC3650MHDARKBRONZE-F b. Spaulding FN2P50D0DBFDM36 Type SF1(exterior) InVue VFS-K-70-MH-NS: 1. 2. 3. 4. 5. 6. 7. 8. Description: Enclosed Micro Floodlight to illuminate a flag pole. Reflector: Diffuse axial parabolic narrow reflector. Housing: Die-cast aluminum, 6.25” x 9.75” x 4.75”. Ballast: High reactance autotransformer. Mounting: 1/2 inch threaded fitter Voltage: [277] [208]. Lamps: MH70W/G12 Alternate Manufacturers: 16520-3 USPS EXTERIOR LIGHTING SPECIFICATION Issued Date: 2/12/2008 EXTERIOR LIGHTING a. b. F. Type SP1(exterior) Lithonia KSF2250M R2 SF DDB [277][208]: 1. 2. 3. 4. 5. 6. 7. 8. G. 4. 5. 6. 7. 8. Description: Rectilinear architectural arm-mounted full cut-off. Reflector: Anodized segmented reflectors. Type III distribution. Housing: Rugged aluminum rectilinear housing with all seams continuously welded for integrity. Corrosion-resistant polyester powder coat Ballast: Constant wattage auto-transformer type, high power factor. Mounting: 20 – 25’ Square straight aluminum pole. Voltage: [277] [208]. Lamps: M400/C/U. Alternate Manufacturers: a. McGraw Edison CAL400MHMT3SFDark bronze b. Hubbell RCS-A-H40-F-Q-DBW4 Type SP5(exterior) Lithonia KSF1175M R2 SF DBB [277] [208: 1. 2. 3. 4. 5. 6. 7. 8. I. Description: Rectilinear architectural arm-mounted sharp cut-off. Reflector: Anodized segmented reflectors, Type II distribution. Housing: Rugged aluminum rectilinear housing with all seams continuously welded for integrity. Corrosion-resistant polyester powder coat Ballast: Constant wattage auto-transformer type, high power factor. Mounting: 20 – 25’ Square straight aluminum pole. Voltage: [277] [208]. Lamps: M250/C/U. Alternate Manufacturers: a. McGraw Edison CAL250MHMT2SFDark bronze OK b. Hubbell RCS-A-H25H3-F-Q-DBW4 Type SP2(exterior) Lithonia KSF2400M R3 SF DDB [277][208]: 1. 2. 3. H. Sterner CA5D/70MH/RN/SW Beta Lighting BCQ6407-D[277][208 Description: Rectilinear architectural arm-mounted full cut-off. Reflector: Anodized segmented reflectors. Type II distribution. Housing: Rugged aluminum rectilinear housing with all seams continuously welded for integrity. Corrosion-resistant polyester powder coat Ballast: Constant wattage auto-transformer type, high power factor. Mounting: 12 – 15’ Square straight aluminum pole. Voltage: [277] [208]. Lamps: M175/C/U. Alternate Manufacturers: a. McGraw Edison CAL175MHMT2SF BZ b. Hubbell RCS-A-H17-H3-F-Q-DBW4 Type CI02Vista AGVSP-LED-DC-HL-C-ZN-WT-UNV-MW: 1. 2. 3. 4. 5. 6. 7. 8. Description: Recessed 9.25”w x 3.3”h x 4.3”d step light with L.E.D. source Features: Die cast aluminum step light with louver face. Housing: Back box constructed of die-cast aluminum alloy. Louvers: Die-cast aluminum alloy. Mounting: Recessed wall mounting. Voltage: Universal (both120 & 277) Lamp: White LED’s included Alternate Manufacturers: a. Kenall MSLS)DBCPWLL [120] [277] (9.25”w x 3.75”h x 3.5”d) 16520-4 USPS MASTER SPECIFICATION Issue Date: 9/17/2005 EXTERIOR LIGHTING WINNETKA CARRIER ANNEX NORTHBROOK, ILLINOIS b. J. 2. 3. 4. 5. 6. 7. A. Lumux SL630/LED/BRONZE [120] [277] (10.25”w x 4”h x 3.25”d) ok Type XF1Canlet 68-02-01-0G-11: 1. 2.3 USPS NO. J80967 COMM. NO. 1597-104 Description: Vaportight incandescent listed and labeled for Class I, Div. 2, Groups C,D, hazardous locations in accordance with article 501 of the National Electrical Code. Lens: Heat and impact resistant glass globe. Housing: Body and guard of lexan polycarbonate. Mounting: Surface ceiling mounted. Voltage: 120 Lamps: 135W/A19/130V Alternate Manufacturer: a. Hubbell NVX15GHG HIGH INTENSITY DISCHARGE (HID) BALLAST Manufacturers: 1. 2. 3. 4. 5. Advance Transformer Company, Rosemont, IL (847) 390-5000. General Electric Company, Nela Park, OH (800) 435-2677. Magnetek, Nashville, TN (615) 316-5100. Osram/Sylvania, Danvers, MA (800) 544-4828. Section 01600 - Product Requirements: Product options and substitutions. Substitutions: Permitted. B. Description: ANSI C82.4, high pressure sodium lamp ballast. C. Provide ballast suitable for lamp specified. D. Voltage: [277] 208 ] 2.4 A. COMPACT FLUORESCENT BALLAST Manufacturers: 1. 2. 3. 4. Advance Transformer Company, Rosemont, IL (847) 390-5000. Motorola, Lake Zurich, IL (800) 654-0089. Magnetek, Nashville, TN (615) 316-5100. Osram/Sylvania, Danvers, MA (800) 544-4828. B. Description: High frequency, energy efficient, electronic fluorescent lamp ballasts with high power factor suitable and compatible for operating the lamps indicated. The lamp crest factor shall measure 1.7 or less. Ballasts shall have a minimum "Ballast Factor" of 0.87. Ballasts shall meet or exceed all EMI and RFI standards of the Federal Communications Commission (FCC) regulations Part 18 (including 15J). Ballasts shall be UL labeled and comply with all local, State and Federal efficiency standards. C. Voltage 120 and 277 volts to match luminaire voltage. 2.5 A. LAMPS High Intensity Discharge (HID) Lamp Manufacturers: 1. 2. 3. General Electric Company, Nela Park, OH (800) 435-2677. Osram/Sylvania, Danvers, MA (800) 544-4828. Philips Lighting Company, Somerset, NJ (800) 555-0050. 16520-5 USPS EXTERIOR LIGHTING SPECIFICATION Issued Date: 2/12/2008 EXTERIOR LIGHTING 4. Section 01600 - Product Requirements: Product options and substitutions. Substitutions: Permitted. B. NEMA CFT designated lamps must pass the federal Toxic Characteristic Leaching Procedure (TCLP) test and be classified non-hazardous waste. C. Lamp Types: As specified for luminaire. Refer to Section 01600 for substitutions and product options. D. Reflector Lamp Beam Patterns: ANSI C78.379. 2.6 A. POLES Manufacturers: 1. 2. 3. Lithonia: #SSA25 6G-DM DDB. McGraw Edison SSA6 M25 Wx. Hubbell SSA-25-60 B. Section 01600 - Product Requirements: Permitted. C. Material and Finish: Aluminum with dark bronze finish. D. Section Shape and Dimensions: 6 inch (15 cm) Square. E. Height: 25 feet, (7.62 m). F. Base: Nonbreakaway. G. Accessories: 1. 2. 3. H. Product options and substitutions. Substitutions: Handhole. Anchor bolts. Base Cover. Approximate Loading Capacity Ratings: 1. 2. 3. Luminaire Weight: 72 pounds. Luminaire and Bracket Effective Projected Area: 5.6 square feet, 12.68 square meters. Steady Wind: [70] [ ___ ] miles per hour minimum, with gust factor of [1.3] [ ___ ]. PART 3 - EXECUTION 3.1 INSTALLATION A. Provide 3000 PSI minimum concrete bases for lighting poles at locations indicated, in accordance with Section 03300 and details shown on drawings. B. Install poles plumb. Provide double nuts to adjust plumb. Grout around each base. C. Install lamps in each luminaire. 16520-6 USPS MASTER SPECIFICATION Issue Date: 9/17/2005 EXTERIOR LIGHTING WINNETKA CARRIER ANNEX NORTHBROOK, ILLINOIS D. 3.2 USPS NO. J80967 COMM. NO. 1597-104 Bond luminaires, metal accessories and metal poles to branch circuit equipment grounding conductor. Provide supplementary 5/8 inch x 10 foot copper clad rod grounding electrode at each pole. FIELD QUALITY CONTROL A. Section 01400 : Field inspection. B. Operate each luminaire after installation and connection. Inspect for improper connections and operation. C. Measure illumination levels to verify conformance with layout and performance requirements. D. Take measurements during night sky, without moon or with heavy overcast clouds effectively obscuring moon. 3.3 A. 3.4 ADJUSTING Aim and adjust luminaires to provide illumination levels and distribution as directed. CLEANING A. Section 01700 - Contract Closeout: Cleaning installed work. B. Clean electrical parts to remove conductive and deleterious materials. C. Remove dirt and debris from enclosure. D. Clean photometric control surfaces as recommended by manufacturer. E. Clean finishes and touch up damage. 3.5 PROTECTION OF FINISHED WORK A. Section 01700 - Contract Closeout: Protecting installed work. B. Relamp all luminaires at Substantial Completion. END OF SECTION 16520-7 USPS EXTERIOR LIGHTING SPECIFICATION Issued Date: 2/12/2008 EXTERIOR LIGHTING Page 1 of 14 General Decision Number: IL080009 08/22/2008 IL9 Superseded General Decision Number: IL20070009 State: Illinois Construction Types: Building, Heavy, Highway and Residential County: Cook County in Illinois. BUILDING, RESIDENTIAL, HEAVY, AND HIGHWAY PROJECTS (does not include landscape projects). Modification Number 0 1 2 3 4 5 6 7 Publication Date 02/08/2008 02/22/2008 03/21/2008 04/25/2008 06/06/2008 07/04/2008 07/25/2008 08/22/2008 ASBE0017-001 06/01/2007 Rates Fringes HAZARDOUS MATERIAL HANDLER includes preparation, wetting, stripping removal scrapping, vacuuming, bagging and disposal of all insulation materials, whether they contain asbestos or not, from mechanical systems..........$ 26.00 15.48 Insulator/asbestos worker Includes the application of all insulating materials, protective coverings, coatings, and finishes to all types of mechanical systems..........$ 37.15 19.18 ---------------------------------------------------------------BOIL0001-001 07/01/2004 Rates Fringes BOILERMAKER......................$ 35.07 16.26 ---------------------------------------------------------------* BRIL0021-001 06/01/2008 Rates Fringes BRICKLAYER.......................$ 38.03 18.25 ---------------------------------------------------------------* BRIL0021-004 06/01/2008 http://www.wdol.gov/wdol/scafiles/davisbacon/IL9.dvb 9/4/2008 Page 2 of 14 Rates Fringes Marble Mason.....................$ 38.03 18.25 ---------------------------------------------------------------* BRIL0052-001 06/01/2008 Rates Fringes Pointer, cleaner and caulker.....$ 38.20 16.41 ---------------------------------------------------------------CARP0555-001 06/01/2004 Rates Fringes CARPENTER CARPENTERS, LATHERS, MLLWRIGHTS, PILEDRIVER, & SOFT FLOOR LAYERS...........$ 34.32 10.93 ---------------------------------------------------------------CARP0555-002 10/01/2004 Rates Fringes CARPENTER (Excluding structures with elevators and structures over 3 1/2 stories)...$ 34.32 10.91 ---------------------------------------------------------------ELEC0009-003 05/26/2008 Rates Fringes Line Construction Groundman...................$ 30.11 40.66% Lineman and Equipment Operator....................$ 38.60 40.66% ---------------------------------------------------------------ELEC0134-001 06/04/2007 Rates Fringes ELECTRICIAN Building....................$ 37.80 18.63 Residential.................$ 37.80 18.23 ---------------------------------------------------------------ELEC0134-002 04/01/1998 Rates Fringes ELECTRICIAN ((CLASS B) (Install magnetic or electronic replacement ballasts either singly or in groups including necessary wiring within fixture; Install replacement lamp holders and/or sockets including necessary wiring within fixture including relocating sockets within fixture; Install replacement http://www.wdol.gov/wdol/scafiles/davisbacon/IL9.dvb 9/4/2008 Page 3 of 14 lighting circuit breakers where necessary; Install replacement lighting switches where necessary; Repair lighting fixtures other than ballast or socket replacements; Rewire chandeliers or incandescent fixtures only within fixtures themselves.).....................$ 20.71 2.975+a+b FOOTNOTES: a-Paid Vacation- Employees who have been employed for one year but less than three years receive 1 week of paid vacation; employees who have been employed three years but less than ten years receive 2 weeks of paid vacation; Employees who have been employed ten years but less than twenty years receive 3 weeks of paid vacation; and employees who have worked twenty or more years receive 4 weeks of paid vacation. b-Funeral Leave-In the instance of the death of a mother, other-in-law-; father, father-in-law, sister, brother, husband, wife, or a child of an employee shall receive up to three days of paid funeral leave. ---------------------------------------------------------------ELEC0134-003 06/07/2004 Rates ELECTRICIAN ELECTRICAL TECHNICIAN.......$ 30.89 Fringes 12.59 The work shall consist of the installation, operation, inspection, maintenance, repair and service of radio, television, recording, voice sound vision production and reproduction, telephone and telephone interconnect, facsimile, data appatatus, coaxial, fibre optic and wireless equipment, appliances and systems used for the transmission and reception of signals of any nature, business, domestic, commercial, education, entertainment and residential purposes, including but not limited to communication and telephone, electronic and sound equipment, fibre optic and data communication systems, and the performance of any task directly related to such installation or service whether at new or existing sites, such tasks to include the placing of wire and cable and electrical power conduit or other raceway work within the equipment room and pulling wire and/or cable through conduit and the installation of any incidential conduit. ---------------------------------------------------------------ELEV0002-003 01/01/2008 Rates ELEVATOR MECHANIC................$ 43.93 Fringes 16.285+A+B FOOTNOTES: http://www.wdol.gov/wdol/scafiles/davisbacon/IL9.dvb 9/4/2008 Page 4 of 14 A. Eight paid holidays: New Year's Day; Memorial Day; Independence Day; Labor Day; Thanksgiving Day; Day after Thanksgiving; Veterans' Day and Christmas Day. B. Employer contributes 8% of regular basic hourly rate as vacation pay credit for employees with more than 5 years of service; and 6% for 6 months to 5 years of service. ---------------------------------------------------------------* ENGI0150-006 06/01/2006 Rates Power equipment operators: GROUP 1....................$ GROUP 2....................$ GROUP 3....................$ GROUP 4....................$ 41.55 40.25 37.70 35.95 Fringes 15.05 15.05 15.05 15.05 POWER EQUIPMENT OPERATORS CLASSIFICATIONS GROUP 1: Mechanic; Asphalt Plant*; Asphalt Spreader; Autograde*; Backhoes with Caisson attachment*:Batch Plant*; Benoto(Requires two Engineers); Boiler and Throttle Valve; Caisson Rigs*; Central Redi-Mix Plant*; Combination Backhoe Front Endloader Machine; Compressor and Throttle Valve; Concrete Breaker (Truck Mounted)*; Concrete Conveyor; Concrete Conveyor, Truck Mounted; Concrete Paver over 27E cu. ft.*; Concrete Paver 27E cu ft and Under*; Concrete Placer*; Concrete Placing Boom; Concrete Pump (Truck Mounted); Concrete Tower; Cranes*; Cranes, Hammerhead*; Cranes, (GCI and similar type Requires two operators only); Creter Crane; Crusher, Stone, etc; Derricks; Derricks, Traveling*; Formless Curb and Gutter Machine*; Grader, Elevating; Grouting Machines; Highlift Shovels or Front Endloader 2 1/4 yd. and over; Hoists, Elevators, Outside Type Rack and pinion and similar Machines; Hoists, One, Two, and Three Drum; Hoists, Two Tugger One Floor; Hydraulic Backhoes*; Hydraulic Boom Trucks; Hydraulic Vac (and similar equipment);Locomotives; Motor Patrol*; Pile Drivers amd Skid Rig*; Post Hole Digger; Pre- Stress Machine; Pump Cretes Dual Ram(Requiring frequent Lubrication and Water); Pump Cretes; Squeeze Cretes-Screw Type Pumps Gypsum Bulker and Pump; Raised and Blind Hole Drill*; Roto Mill Grinder (36" and Over)*; Roto Mill Grinder (Less Than 36")*; Scoops-Tractor Drawn; Slip-Form Paver*; Straddle Buggies; Tournapull; Tractor with Boom, and Side Boom; and Trenching Machines*. GROUP 2: Bobcat (over 3/4 cu yd); Boilers; Broom, Power Propelled; Bulldozers; Concrete Mixer (Two Bag and over); Conveyor, Portable; Forklift Trucks; Greaser Engineer; Highlift Shovels or Front End loaders under 2 1/4 cu yd; Aotomatic Hoists, Hoists, Inside Elevators; Hoists, Sewer Dragging Machine; Hoists, Tugger Single Drum; Laser Screed; Rock Drill (Self-Propelled); Rock Drill (Truck Mounted)*; Rollers; Steam Generators; Tractors; Tractor Drawn Vibratory Roller (Receives an additional $.50 per hour); Winch Trucks with "A" Frame. GROUP 3: Air Compressor-Small 250 and Under (1 to 5 not to http://www.wdol.gov/wdol/scafiles/davisbacon/IL9.dvb 9/4/2008 Page 5 of 14 exceed a total of 300 ft); Air Compressor-Large over 250; Combination-Small Equipment Operator; Generator- Small 50 kw and under; Generator-Large over 50 kw; Heaters, Mechanical; Hoists, Inside Elevators (Remodeling or Renovatin work); Hydrualic Power Units (Pile Driving, Extracting, and Drilling); Low Boys; Pumps Over 3" (1 To 3 not to exceed a total of 300 ft); Pumps, Well Points; Welding Machines (2 through 5); Winches, 4 Small Electric Drill Winches; Bobcat (up to and including 3/4 cu yd) GROUP 4 - Bobcats and/or other Skid Steer Loaders; Brick Forklifts; Oilers *-Requires Oiler ---------------------------------------------------------------* ENGI0150-025 06/01/2008 Rates Power equipment operators: GROUP 1.....................$ GROUP 2.....................$ GROUP 3.....................$ GROUP 4.....................$ GROUP 5.....................$ 42.00 41.45 39.40 38.00 36.80 Fringes 20.30 20.30 20.30 20.30 20.30 POWER EQUIPMENT OPERATOR CLASSIFICATIONS GROUP 1: Asphalt Plant*; Asphalt Heater and Planer combination; Asphalt Heater Scarfire*, Asphalt Spreader; Autograder/ GOMACO or similar; ABG Paver*, Backhoes with Caisson attachment*, Ballast Regulator, Belt Loader*; Caisson Rigs*Car Dumper, Central Redi-Mix Plant*, Combination Backhoe; Front End Loader Machine (1 cu yd or over Backhoe bucket or with attachments); Concrete Breaker (truck mounted); Concrete Conveyor; Concrete Paver over 27E cu ft*; Concrete Placer*; Concrete Tube Float; Cranes, all attachments*; Cranes, Hammerhead, Linden, Peco and machines of a like nature*; Creter Crane; Crusher, stone; All Derricks; Derrick Boats; Derricks, traveling*; Dowell Machine with Air Compressor ($1.00 above Class 1); Dredges*; Field Mechanic Welder; Formless Curb and Gutter Machine*; Gradall and machines of a like nature*; Grader, Elevating; Grader, Motor Grader, Motor Patrol, Auto Patrol, Form Grader, Pull Grader, Subgrader; Guard Rail Post Driver mounted*; Hoists, one, two, and three Drum; Hydraulic Backhoes*; Backhoes with Shear attachments*; Mucking Machine; Pile Drivers and Skid Rig*; Pre-Stress Machine; Pump Cretes Dual Ram (requires frequent lubrication and water)*; Rock Drill- Crawler or Skid Rig*; Rock Drill truck mounted*; Rock/ Track Tamper; Roto Mill Grinder, (36" and over)*; Slip-Form Paver*; Soil Test Drill Rig, truck mounted*; Straddle Buggies; Hydraulic Telescoping Form (tunnel); Tractor Drawn Belt Loader*; Tractor Drawn Belt Loader with attached Pusher (two engineers); Tractor with boom; Tractaire with attachment; Traffic Barrier Transfer Machine*; Trenching Machine; Truck Mounted Concrete Pump with boom*; Underground Boring and/or Mining Machines 5 ft in diameter and over tunnel, etc.*; Wheel Excavator* & Widener (Apsco); Raised or Blind Hoe Drill, Tunnel & Shaft* http://www.wdol.gov/wdol/scafiles/davisbacon/IL9.dvb 9/4/2008 Page 6 of 14 GROUP 2: Batch Plant*; Bituminous Mixer; Boiler and Throttle Valve; Bulldozer; Car Loader Trailing Conveyors; Combination Backkhoe Front End Loader Machine, (less than 1 cu yd Backhoe Bucket with attachments); Compressor and Throttle Valve; Compressor, common receiver (3); Concrete Breaker or Hydro Hammer; Concrete Grinding Machine; Concrete Mixer or Paver 7S series to and including 27 cu ft; Concrete Spreader; Concrete Curing Machine; Burlap Machine; Belting Machine and Sealing Machine; Concrete Wheel Saw; Conveyor Muck Cars (Haglund or similar type); Drills (all); Finishing Machine-Concrete; Greaser Engineer; Highlift Shovels or Front End Loader; Hoist- Sewer Dragging Machine; Hydraulic Boom Trucks, all attachments; Hydro-Blaster (requires two operators); Laser Screed*; Locomotives, Dinky; Off-Road Hauling Units (including articulating); Pump Cretes; Squeeze Cretes-Screw Type pumps, Gypsum Bulker and Pump; Roller Asphalt; Rotary Snow Plows; Rototiller, Seaman, self-Propelled; Scoops-Tractor Drawn; Self- propelled Compactor; Spreader-Chip-Stone; Scraper; Scraper-Prime Mover in Tandem regardless of size (add $1.00 to Group 2 hourly rate for each hour and for each machine attached thereto add $1.00 to Group 2 hourly rate for each hour); Tank Car Heater; Tractors, Push, pulling Sheeps Foot, Disc, or Compactor, etc; Tug Boats GROUP 3: Boilers; Brooms, all power propelled; Cement Supply Tender; Compressor, Common Receiver (2); Concrete Mixer, two bag and over; Conveyor, Portable; Farm type Tractors used for mowing, seeding, etc; Fireman on Boilers; Forklift Trucks; Grouting Machines; Hoists, Automatic; Hoists, all Elevators; Hoists, Tugger single Drum; Jeep Diggers; Low Boys; Pipe Jacking Machines; Post-hole Digger; Power Saw, Concrete, Power Driven; Pug Mills; Rollers, other than asphalt; Seed and Straw Blower; Steam Generators; Stump Machine; Winch Trucks with A-Frame; Work Boats; Tamper-Form motor driven GROUP 4: Air compressor - Small 250 and under (1 to 5 not to exceed a total of 300 ft); Air Compressor - Large over 250; Combination - Small Equipment Operator; Directional Boring Machine; Generators - Small 50 kw and under; Generators Large , over 50 kw; Heaters, Mechanical; Hydraulic power unit (Pile Driving, Extracting or Drilling); Light Plants (1 to 5); Pumps, over 3" (1 to 3, not to exceed a total of 300 ft); Pumps, Well Points; Tractaire; Welding Machines (2 through 5); Winches, 4 small electric drill winches; GROUP 5: Bobcats (All); Brick Forklifts; Oilers; Directional Boring *Requires Oiler ---------------------------------------------------------------IRON0001-026 06/01/2008 Rates Fringes IRONWORKER (Structural and Reinforcing).....................$ 40.25 24.99 ---------------------------------------------------------------- http://www.wdol.gov/wdol/scafiles/davisbacon/IL9.dvb 9/4/2008 Page 7 of 14 IRON0063-001 06/01/2008 Rates Fringes IRONWORKER, ORNAMENTAL...........$ 39.05 19.64 ---------------------------------------------------------------IRON0063-002 06/01/2007 Rates Fringes IRONWORKER Fence Erector...............$ 28.64 12.75 Metal Fence Erector.........$ 22.54 12.04 ---------------------------------------------------------------IRON0136-001 07/01/2006 Rates Fringes IRONWORKER Machinery Movers & Riggers..$ 30.24 19.87 Master Riggers..............$ 32.74 19.87 ---------------------------------------------------------------LABO0002-006 06/01/2007 Rates Laborers: GROUP 1....................$ 33.15 GROUP 2....................$ 33.15 GROUP 3....................$ 33.225 GROUP 4....................$ 33.25 GROUP 5....................$ 33.30 GROUP 6....................$ 33.35 GROUP 7....................$ 33.375 GROUP 8....................$ 33.375 GROUP 9....................$ 33.475 GROUP 10....................$ 33.60 GROUP 11....................$ 33.425 GROUP 12....................$ 34.15 Fringes 13.87 13.87 13.87 13.87 13.87 13.87 13.87 13.87 13.87 13.87 13.87 13.87 LABORER CLASSIFICATIONS GROUP 1: Building Laborers; Plasterer Tenders; Pumps for Dewatering; and other unclassified laborers. GROUP 2: Fireproofing and Fire Shop laborers. GROUP 3: Cement Gun. GROUP 4: Chimney over 40 ft.; Scaffold Laborers. GROUP 5: Cement Gun Nozzle Laborers (Gunite); Windlass and capstan person. GROUP 6: Stone Derrickmen & Handlers. GROUP 7: Jackhammermen; Power driven concrete saws; and other power tools. GROUP 8: Firebrick & Boiler Laborers. http://www.wdol.gov/wdol/scafiles/davisbacon/IL9.dvb 9/4/2008 Page 8 of 14 GROUP 9: Chimney on fire brick; Caisson diggers; & Well Point System men. GROUP 10: Boiler Setter Plastic Laborers. GROUP 11: Jackhammermen on fire brick work only. GROUP 12: Dosimeter use (any device) monitoring nuclear exposure); Asbestos Abatement Laborer; Toxic and Hazardous Waste Removal Laborers. ---------------------------------------------------------------LABO0002-007 06/01/2007 Rates Laborers: GROUP GROUP GROUP GROUP GROUP 1.....................$ 2.....................$ 3.....................$ 4.....................$ 5.....................$ 33.15 33.425 33.30 33.425 34.15 Fringes 13.87 13.87 13.87 13.87 13.87 LABORER CLASSIFICATIONS GROUP 1: Common laborer; Tenders; Material expeditor (asphalt plant); Street paving, Grade separation, sidewalk, curb & gutter, strippers & All laborers not otherwise mentioned GROUP 2: Ashpalt tampers & smoothers; Cement gun laborers GROUP 3: Cement Gun Nozzle (laborers), Gunite GROUP 4: Rakers, Lutemen; Machine-Screwmen; Kettlemen; Mixermen; Drun-men; Jackhammermen (asphalt); Paintmen; Mitre box spreaders; Laborers on birch, overman and similar spreader equipment; Laborers on APSCO; Laborers on air compressor; Paving Form Setter; Jackhammermen (concrete); Power drive concrete saws; other power tools. GROUP 5: Asbestos Abatement Laborers; Toxic and Hazardous Waste Removal Laborers, Dosimeter (any device) monitoring nuclear exposure ---------------------------------------------------------------LABO0002-008 06/01/2007 Rates Laborers: (Compressed Air) 0 - 15 POUNDS...............$ 16 - 20 POUNDS..............$ 21 - 26 POUNDS..............$ 27 - 33 POUNDS..............$ 34 - AND OVER...............$ Laborers: (Tunnel and Sewer) GROUP 1.....................$ GROUP 2.....................$ GROUP 3.....................$ GROUP 4.....................$ Fringes 34.15 34.65 35.15 36.15 37.15 13.87 13.87 13.87 13.87 13.87 33.15 33.275 33.375 33.50 13.87 13.87 13.87 13.87 http://www.wdol.gov/wdol/scafiles/davisbacon/IL9.dvb 9/4/2008 Page 9 of 14 GROUP 5.....................$ 34.15 13.87 LABORER CLASSIFICATIONS (TUNNEL) GROUP 1: Cage tenders; Dumpmen; Flagmen; Signalmen; Top laborers GROUP 2: Air hoist operator; Key board operator; concrete laborer; Grout; Lock tenders (Free Air Side); Steel setters; Tuggers; Switchmen; Car pusher GROUP 3: Concrete repairmen; Lock tenders (pressure side); Mortar men; Muckers; Grout machine operators; Track layers GROUP 4: Air trac drill operator; Miner; Bricklayer tenders; Concrete blower operator; Drillers; Dynamiters; Erector operator; Form men; Jackhammermen; Powerpac; Mining machine operators; Mucking machine operator; Laser beam operator; Liner plate and ring setters; Shield drivers; Power knife operator; Welder- burners; Pipe jacking machine operator; skinners; Maintenance technician GROUP 5: Asbestos abatement laborer; Toxic and hazardous waste removal laborer; Dosimeter (any device) monitoring nuclear exposure LABORER CLASSIFICATIONS (SEWER) GROUP 1: Signalmen; Top laborers and All other laborers GROUP 2: Concrete laborers and Steel setters GROUP 3: Cement carriers; Cement mixers; Concrete repairmen; Mortar men; Scaffold men; Second Bottom men GROUP 4: Air trac drill operator; Bottom men; Bracers-bracing; Bricklayer tenders; Catch basin diggers; Drainlayers; dynamiters; Form men; Jackhammermen; Powerpac; Pipelayers; Rodders; Welder-burners; Well point systems men GROUP 5: Asbestos abatement laborer, Toxic and hazardous waste removal laborer; Dosimeter (any device) monitoring nuclear exposure ---------------------------------------------------------------LABO0225-001 06/01/2007 Rates Laborers: (DEMOLITION/WRECKING) Group 1.....................$ 26.85 Group 2.....................$ 32.40 Group 3.....................$ 33.15 Fringes 13.87 13.87 13.87 LABORER CLASSIFICATIONS GROUP 1 - Complete Demolition GROUP 2 - Interior Wrecking and Strip Out Work http://www.wdol.gov/wdol/scafiles/davisbacon/IL9.dvb 9/4/2008 Page 10 of 14 GROUP 3 - Asbestos Work with Complete Demolition/Wrecking or Strip Out Work ---------------------------------------------------------------* MARB0067-001 06/01/2008 Rates Fringes TERRAZZO WORKER/SETTER...........$ 37.39 17.38 TILE FINISHER....................$ 32.15 13.62 TILE SETTER......................$ 38.63 15.34 ---------------------------------------------------------------* MARB0087-001 06/01/2008 Rates Fringes MARBLE FINISHER..................$ 28.65 18.17 ---------------------------------------------------------------PAIN0014-001 06/01/2008 Rates Fringes PAINTER Including Taper.............$ 36.90 16.32 ---------------------------------------------------------------PAIN0027-001 06/01/2008 Rates Fringes GLAZIER..........................$ 37.00 20.13 ---------------------------------------------------------------PLAS0005-002 07/01/2008 Rates Fringes PLASTERER........................$ 38.10 16.35 ---------------------------------------------------------------PLAS0502-001 06/01/2008 Rates Fringes CEMENT MASON/CONCRETE FINISHER...$ 41.85 15.43 ---------------------------------------------------------------PLUM0130-001 06/01/2007 Rates Fringes PLUMBER..........................$ 41.00 16.93 ---------------------------------------------------------------* PLUM0597-002 06/01/2008 Rates Fringes PIPEFITTER.......................$ 42.05 17.58 ---------------------------------------------------------------ROOF0011-001 12/01/2007 Rates Fringes ROOFER...........................$ 35.00 11.00 ---------------------------------------------------------------- http://www.wdol.gov/wdol/scafiles/davisbacon/IL9.dvb 9/4/2008 Page 11 of 14 SFIL0281-001 01/01/2008 Rates Fringes SPRINKLER FITTER.................$ 40.50 16.00 ---------------------------------------------------------------SHEE0073-001 01/01/2007 Rates Fringes Sheet Metal Worker...............$ 36.96 17.42 ---------------------------------------------------------------SHEE0073-002 01/01/2007 Rates Fringes Sheet Metal Worker ALUMINUM GUTTER WORK........$ 24.03 17.42 ---------------------------------------------------------------TEAM0731-001 06/01/2008 Rates TRUCK DRIVER 2 & 3 Axles.................$ 4 Axles.....................$ 5 Axles.....................$ 6 Axles.....................$ Fringes 30.70 30.95 31.15 31.35 12.20 12.20 12.20 12.20 FOOTNOTES FOR TRUCK DRIVERS: A. Paid Holidays: New Year's Day, Memorial Day, Independence Day, Labor Day, Thanksgiving Day, and Christmas Day. B. 900 straight time hours or more in 1 calendar year for the same employer shall receive 1 week paid vacation; 3 years - 2 weeks paid vacation; 10 years - 3 weeks paid vacation; 20 years - 4 weeks paid vacation. ---------------------------------------------------------------TEAM0731-002 06/01/2008 Rates Fringes TRUCK DRIVER (DEMOLITION) 2 OR 3 Axles................$ 30.70 12.20 4 Axles.....................$ 30.95 12.20 5 Axles.....................$ 31.15 12.20 6 Axles.....................$ 31.35 12.20 ---------------------------------------------------------------TEAM0731-003 05/01/1997 Rates Fringes Traffic Control Device Monitor TRAFFIC SAFETY WORKERS: Traffic Safety Worker primary duties include but are not limited to the delivery, maintenance and http://www.wdol.gov/wdol/scafiles/davisbacon/IL9.dvb 9/4/2008 Page 12 of 14 pick-up of traffic control devices, the set-up and installation of traffic signs, pavement markings, barricades, crash barrels and glare screens, and traffic control surveillance, the repair and maintenance of the company's trucks, cars, arrow boards, message signs, barricade and sign fabrication equipment......$ 16.15 108.75/wk+a FOOTNOTE a: 1. The following paid holidays: New Year's Day; Memorial Day; Independence Day; Labor Day; Thanksgiving Day; and Christmas Day provided the employee has earned a vacation the previous year or have worked thirty-one days in the current year before the holiday, or have seniority as stated herein; work the scheduled work day before and the scheduled day after the holiday; work one day in the holiday week; and work one scheduled work day after the holiday. 2. Paid vacation is earned the first year of employment, but may not be taken until after their first anniversary date. One and two years of employment receive 40 hours of paid vacation; Three thru nine years of employment receive 80 hours of paid vacation; Ten thru nineteen years of employment receive 120 hours of paid vacation; and Twenty years and over receive 160 hours of paid vacation. 3. Personal time (floating holidays) will be earned on a per hour worked basis. New employees will earn personal time during the first year of employment, but may not be take personal time until after their first anniversary date. Personal time is earned in the following way: One and two years receive 8 hours of personal time; Three thru nine years receive sixteen hours of personal time; and ten years and over receive twenty-four hours of personal time. ---------------------------------------------------------------TEAM0786-001 06/01/2004 Rates TRUCK DRIVER 2 & 3 Axles.................$ 4 Axles.....................$ 5 Axles.....................$ 6 Axles.....................$ Fringes 27.625 27.875 28.075 28.625 d,e,f d,e,f d,e,f d,e,f FOOTNOTES FOR TRUCK DRIVERS (BUILDING & RESIDENTIAL): d. $327.00 per week. e. Paid Holidays: New Year's Day, Memorial Day, Independence Day, Labor Day, Thanksgiving Day, and Christmas Day. http://www.wdol.gov/wdol/scafiles/davisbacon/IL9.dvb 9/4/2008 Page 13 of 14 f. 900 straight time hours or more in 1 calendar year for the same employer shall receive 1 week paid vacation; 3 years - 2 weeks paid vacation; 10 years - 3 weeks paid vacation; 20 years - 4 weeks paid vacation. ---------------------------------------------------------------WELDERS - Receive rate prescribed for craft performing operation to which welding is incidental. ================================================================ Unlisted classifications needed for work not included within the scope of the classifications listed may be added after award only as provided in the labor standards contract clauses (29CFR 5.5 (a) (1) (ii)). ---------------------------------------------------------------In the listing above, the "SU" designation means that rates listed under the identifier do not reflect collectively bargained wage and fringe benefit rates. Other designations indicate unions whose rates have been determined to be prevailing. ---------------------------------------------------------------WAGE DETERMINATION APPEALS PROCESS 1.) Has there been an initial decision in the matter? This can be: * * * * an existing published wage determination a survey underlying a wage determination a Wage and Hour Division letter setting forth a position on a wage determination matter a conformance (additional classification and rate) ruling On survey related matters, initial contact, including requests for summaries of surveys, should be with the Wage and Hour Regional Office for the area in which the survey was conducted because those Regional Offices have responsibility for the Davis-Bacon survey program. If the response from this initial contact is not satisfactory, then the process described in 2.) and 3.) should be followed. With regard to any other matter not yet ripe for the formal process described here, initial contact should be with the Branch of Construction Wage Determinations. Write to: Branch of Construction Wage Determinations Wage and Hour Division U.S. Department of Labor 200 Constitution Avenue, N.W. Washington, DC 20210 2.) If the answer to the question in 1.) is yes, then an interested party (those affected by the action) can request review and reconsideration from the Wage and Hour Administrator (See 29 CFR Part 1.8 and 29 CFR Part 7). Write to: http://www.wdol.gov/wdol/scafiles/davisbacon/IL9.dvb 9/4/2008 Page 14 of 14 Wage and Hour Administrator U.S. Department of Labor 200 Constitution Avenue, N.W. Washington, DC 20210 The request should be accompanied by a full statement of the interested party's position and by any information (wage payment data, project description, area practice material, etc.) that the requestor considers relevant to the issue. 3.) If the decision of the Administrator is not favorable, an interested party may appeal directly to the Administrative Review Board (formerly the Wage Appeals Board). Write to: Administrative Review Board U.S. Department of Labor 200 Constitution Avenue, N.W. Washington, DC 20210 4.) All decisions by the Administrative Review Board are final. ================================================================ END OF GENERAL DECISION http://www.wdol.gov/wdol/scafiles/davisbacon/IL9.dvb 9/4/2008