HARDWIRED SURGE PROTECTIVE DEVICE ANSI / UL 1449 3rd Edition IG1240RC3 • For 120/240 VAC Single phase applications Also called 120/240 VAC Split phase • For installation in Type 1 & 2 locations Main panel • Parallel installation • All Mode protection 6 distinct protection modes Line-to-Neutral, Line-to-Ground Neutral-to-Ground, Line-to-Line • Individual thermally protected components • Green LED status indicator light • NEMA 3R polycarbonate plastic enclosure 1/2” nipple wire entry • 30” 12-gauge color coded leads • Permanently attached mounting feet • Flush mounting option (kit number IG1240FMP33) • CSA Listed to U.S. and Canadian safety standards ANSI / UL 1449 3rd Edition • Nominal Discharge Current Rating (In): 20 kA • Short Circuit Current Rating (SCCR) 50 kA • Five year product warranty • Five year $10,000 connected equipment warranty Type 1 & 2 Type 2 4.182” 5.26” 1” 4.182” 3.335” 1.75” 3.93” Appliance and Electronics Residential sites only • Compatible with power line type home automation and X10 systems Features and Applications: The IG1240RC3 features full mode protection and is recommended for residential and commercial applications. It is intended for installation on 120/240 volt AC panels. The IG1240RC3 incorporates the newest developments in large MOV technology and provides individual component thermal protection and monitoring. The failure of a single component will turn the LED indicator OFF. Flush Mount Plate The “All Mode” protective configuration provides protection between every conductor in the electrical system. When installed on service entrance, main panel, or sub-panel, protection is provided against all possible modes of surge energy with distinct line-to-line, line-to-neutral, line-to-ground, neutral-to-ground protection paths. The IG1240RC3 carries a 5 year product and 5 year residential connected equipment warranty of up to $10,000.00. See the complete warranty for details. Performance Ratings: Operating Frequencies: 50, 60, 400 Hz. Maximum Continuous Operating Voltage (MCOV): Line-to-Neutral150 VAC Line-to-Ground300 VAC Neutral-to-Ground150 VAC Line-to-Line300 VAC UL 1449 Voltage Protection Rating - (VPR): Line to Neutral 700 Line to Ground 1200 Neutral to Ground 700 Line to Line1200 Specifications: Configuration: Parallel technology permits installation over a wide range of applications and ampacities. Compact design provides a small footprint for easy installation. Protection Modes: All Mode protection; line to line, line to neutral, line to ground and neutral to ground. Components: Board configuration provides Very Low Impedance (VLI) surge paths. Thermal Protection: MOVs contain thermal detection and protection. Components react to excessive heat stress at each position and will trigger the circuit to decouple the affected suppression component. Operational Indicators: Dedicated circuits monitor each component in each mode and control the LED indicator. Lighted green indicator represents normal power-on and unit operational condition. Enclosure: NEMA 3R polycarbonate. Mounting: Two tabs molded into the unit housing are located on two faces. The unit may also be mounted by the use of the 1/2” offset nipple. Wiring: 30” of 12 gauge stranded copper wire is preconnected for each phase, neutral and ground. Wires exit the enclosure through a 1/2” nipple located at the left side of the enclosure. Wire Color Code: Black: phase leads, White: neutral lead, Green: ground lead. Weight: 1.1 pounds, 4.7 pounds in master carton of 4 units. Ambient Operating Temperature: -40º to +85º C (-40º to + 185º F) Agency Listings: cCSAus to ANSI / UL1449 3rd Edition Wiring Diagram: Type 1 Ground L1 L2 Wiring Diagram: Type 2 Utility /Power Feed BLACK BLACK Main panel or Sub panel BLACK BLACK WHITE WHITE GREEN GREEN Type 1 Surge Protection Devices may be installed without the use of a Circuit Breaker. Use of a Circuit Breaker is optional. A 15 or 20 Amp 2-pole breaker is recommended for ease of installation and convenient disconnect. LIMITED 5 YEAR WARRANTY If within the warranty period specified, this product fails due to a defect in material or workmanship, Intermatic Incorporated will repair or replace it, at its sole option, free of charge. This warranty is extended to the original household purchaser only and is not transferable. This warranty does not apply to: (a) damage to units caused by accident, dropping or abuse in handling, acts of God or any negligent use; (b) units which have been subject to unauthorized repair, opened, taken apart or otherwise modified; (c) units not used in accordance with instructions; (d) damages exceeding the cost of the product; (e) sealed lamps and/or lamp bulbs, LED’s and batteries; (f) the finish on any portion of the product, such as surface and/or weathering, as this is considered normal wear and tear; (g) transit damage, initial installation costs, removal costs, or reinstallation costs. INTERMATIC INCORPORATED WILL NOT BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES, SO THE ABOVE LIMITATION OR EXCLUSION MAY NOT APPLY TO YOU. THIS WARRANTY IS IN LIEU OF ALL OTHER EXPRESS OR IMPLIED WARRANTIES. ALL IMPLIED WARRANTIES, INCLUDING THE WARRANTY OF MERCHANTABILITYANDTHEWARRANTY OF FITNESS FORA PARTICULAR PURPOSE,ARE HEREBY MODIFIEDTO EXIST ONLYAS CONTAINED INTHIS LIMITED WARRANTY, AND SHALL BE OF THE SAME DURATION AS THE WARRANTY PERIOD STATED ABOVE. SOME STATES DO NOT ALLOW LIMITATIONS ON THE DURATION OF AN IMPLIED WARRANTY, SO THE ABOVE LIMITATION MAY NOT APPLY TO YOU. This warranty service is available by either (a) returning the product to the dealer from whom the unit was purchased, or (b) completing a warranty claim on line at www.intermatic.com. This warranty is made by: Intermatic Incorporated Customer Service, 7777 Winn Rd., Spring Grove, Illinois 60081-9698 / 815-675-7000 http://www.intermatic.com ©2010 Intermatic Inc. 7777 Winn Road, Spring Grove, IL 60081 www.intermatic.com 300IG10276