Electromechanical Relays Selection Guide Latching Non-Latching JAN Commercial RF Established Reliability Surface-Mount Environmental Attenuated Switching Solutions Teledyne Relays has been the world’s innovative leader in manufacturing ultraminiature, hermetically sealed, electromechanical and solid-state switching products for more than 40 years. The company’s comprehensive product line meets a wide range of requirements for defense and aerospace, industrial, commercial, medical and RF & wireless uses. Business Focus • MIL QPL & COTS Solid-State Relays • MIL QPL & COTS Electromechanical Relays • HiRel (Space) Electromechanical Relays • RF & Microwave Relays & Coaxial Switches • Industrial Solid-State Relays • Switching Matrices Markets • Commercial & Military Aviation • Defense & Aerospace • Telecom/Communications (Wireless) • Instrumentation & Test • Industrial Power & Motion Control • Medical Applications Teledyne Relays offer superior signal integrity up to 12 Gbps. See the RF relays section in our website. (800) 284-7007 • www.teledynerelays.com ♦ Product Assurance Under an aggressive Total Quality Management (TQM) program, Teledyne Relays has embraced a “continuous improvement” culture. With recognized certifications such as AS/EN/JISQ 9100 - Revision B and ISO 9001:9002, DSCC MIL-STD-790 and Boeing D6-82479 Appendix A, Teledyne Relays has become a primary supplier of switching solutions with the highest quality and reliability to industry leaders around the world. Technical Service & Customer Support Teledyne Relays provides easy access to technical service and customer support. Our websites make it easy to find technical information, buy products and even get e-mail responses within 24 hours. Switching solutions are only a mouse click away at www.teledynerelays.com or at teledyne-europe.com. Information about coax switches is available at www.teledynecoax.com. An online search function helps engineers locate specific solid-state relays, electromechanical relays and coaxial switches quickly by selecting parameters via drop-down Parametric Search — The Teledyne Relays website allows engineers to use drop-down menus to select relays and switches based on various parameters. +44 (0) 1236 453124 • www.teledyne-europe.com © 2008 Teledyne Relays RF SWITCHING SOLUTIONS CCR-59 and CCR-33K Coaxial Switches • DC to 33 GHz • Excellent insertion loss repeatability • Ultra low passive intermodulation (PIM) • 5 million cycles characteristic life • Failsafe and latching GRF312 Surface-Mount Relays • DC to 8GHz • Signal Integrity measured to 12 Gbps • Excellent pole-to-pole Isolation • Pick-and-place surface mount solution • Hermetically sealed - immune to cleaning solutions (800) 351-7368 • www.teledynecoax.com (800) 596-3855 • www.teledynerelays.com © 2008 Teledyne Relays SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE Page 1 RF Relays Selection Matrix Nominal Coil D P D T N O N L A T C H I N G Isolation Pole to Across Insertion Series Voltage Resistance Max Range VSWR Pole Contacts Loss (dB) (Vdc) (Ω) (GHz) (GHz) (dB) (dB) 5 50 DC-1 1.1 : 1 40 30 0.1 RF100 12 390 1-2 1.2 : 1 35 25 0.3 3 5 100 RF103 2-3 1.5 : 1 33 22 0.5 12 800 5 50 DC-1 1.1 : 1 50 34 0.2 GRF100 1-2 1.1 : 1 45 27 0.2 12 390 2-3 1.1 : 1 55 27 0.3 6 5 100 3-4 1.2 : 1 38 28 0.4 GRF103 4-5 1.5 : 1 40 26 0.7 12 800 5-6 1.8 : 1 38 24 1.1 5 50 DC-1 1.1 : 1 35 35 0.2 SGRF100 1-2 1.2 : 1 30 30 0.3 12 390 2-3 1.2 : 1 29 29 0.5 6 5 100 3-4 1.3 : 1 28 27 0.7 SGRF103 4-5 1.6 : 1 27 25 0.9 12 800 5-6 1.7 : 1 25 25 1.0 5 64 DC-1 1.1 : 1 50 35 0.1 GRF172 12 400 2.5 1-2 1.2 : 1 43 27 0.2 26.5 1600 2-3 1.1 : 1 50 25 0.2 5 50 DC-1 1.1 : 1 38 30 0.1 RF300 12 390 1-2 1.1 : 1 30 24 0.2 3 5 100 RF303 2-3 1.2 : 1 25 22 0.3 12 850 5 50 DC-1 1.1 : 1 46 32 0.1 GRF300 1-2 1.1 : 1 42 30 0.2 12 390 2-3 1.1 : 1 40 30 0.2 6 5 100 3-4 1.2 : 1 38 30 0.4 GRF303 4-5 1.3 : 1 35 28 0.8 12 850 5-6 1.4 : 1 30 25 0.9 GRF100 Page 2 Frequency SGRF103 (800) 284-7007 • www.teledynerelays.com ♦ GRF172 +44 (0) 1236 453124 • www.teledyne-europe.com GRF300 © 2008 Teledyne Relays RF Relays Selection Matrix Nominal Coil Series SGRF300 SGRF303 D P D T N O N L A T C H I N G Voltage Resistance Max Range VSWR (Vdc) (Ω) (GHz) (GHz) 5 50 12 390 5 100 12 850 5 50 RF312 N O N L A T C H RF311 RF331 6 8 12 390 5 50 GRF312 S P D T Frequency 8 12 390 5 12 63 500 26.5 2000 5 12 125 1025 26.5 4000 8 DC-1 1-2 2-3 3-4 4-5 5-6 DC-1 1-2 2-3 3-4 4-5 5-6 6-7 7-8 DC-1 1-2 2-3 3-4 4-5 5-6 6-7 7-8 DC-1 1-2 2-3 3-4 4-5 5-6 6-7 7-8 1.1 : 1 1.1 : 1 1.1 : 1 1.1 : 1 1.1 : 1 1.4 : 1 1.1 : 1 1.1 : 1 1.1 : 1 1.1 : 1 1.1 : 1 1.1 : 1 1.2 : 1 1.3 : 1 1.1 : 1 1.1 : 1 1.1 : 1 1.1 : 1 1.1 : 1 1.2 : 1 1.4 : 1 1.8 : 1 1.1 : 1 1.2 : 1 1.4 : 1 1.5 : 1 1.3 : 1 1.4 : 1 1.6 : 1 1.5 : 1 Isolation Pole to Across Insertion Pole Contacts Loss (dB) (dB) (dB) 43 33 0.2 40 38 0.2 45 35 0.3 28 44 0.6 23 35 0.7 18 32 0.8 45 30 0.1 35 24 0.2 30 22 0.3 38 27 0.4 26 32 0.5 25 40 0.6 23 25 0.7 22 24 0.8 70 40 0.1 65 32 0.2 50 34 0.3 35 38 0.4 35 42 0.6 38 33 0.4 40 28 0.7 42 28 1.3 38 0.1 32 0.2 27 0.3 23 0.3 20 0.4 20 0.5 17 0.7 17 0.8 GRF312 © 2008 Teledyne Relays SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE SGRF303 Page 3 RF Relays Selection Matrix Nominal Coil Series S P D T N O N L A T C H GRF311 RF180 D P D T L A T C H I N G GRF180 Frequency Voltage Resistance Max Range VSWR (Vdc) (Ω) (GHz) (GHz) 5 63 12 500 26.5 2000 5 61 12 500 26.5 2000 5 61 12 500 26.5 2000 5 61 8 6 6 GRF342 S P D T L A T C H RF341 6 12 500 5 61 12 500 26.5 2000 6 (800) 284-7007 • www.teledynerelays.com 1.1 : 1 1.2 : 1 1.3 : 1 1.4 : 1 1.4 : 1 1.4 : 1 1.5 : 1 1.5 : 1 1.1 : 1 1.1 : 1 1.2 : 1 1.2 : 1 1.4 : 1 2.2 : 1 1.1 : 1 1.1 : 1 1.2 : 1 1.2 : 1 1.5 : 1 2.1 : 1 1.1 : 1 1.1 : 1 1.2 : 1 1.1 : 1 1.1 : 1 1.4 : 1 1.1 : 1 1.1 : 1 1.1 : 1 1.1 : 1 1.2 : 1 1.3 : 1 GRF180 GRF311 Page 4 DC-1 1-2 2-3 3-4 4-5 5-6 6-7 7-8 DC-1 1-2 2-3 3-4 4-5 5-6 DC-1 1-2 2-3 3-4 4-5 5-6 DC-1 1-2 2-3 3-4 4-5 5-6 DC-1 1-2 2-3 3-4 4-5 5-6 Isolation Pole to Across Insertion Pole Contacts Loss (dB) (dB) (dB) 42 0.1 32 0.2 27 0.3 27 0.4 26 0.5 23 0.7 19 1.0 19 1.2 55 40 0.1 52 35 0.2 50 30 0.3 45 29 0.3 32 28 0.7 30 26 1.2 55 45 0.1 50 36 0.1 40 35 0.2 35 31 0.4 30 30 0.8 25 29 1.3 50 35 0.2 43 35 0.2 35 34 0.3 30 30 0.4 28 29 0.5 27 27 0.7 40 0.2 35 0.3 30 0.5 27 0.6 25 0.8 24 1.5 ♦ +44 (0) 1236 453124 • www.teledyne-europe.com GRF342 © 2008 Teledyne Relays RF Relays Selection Matrix Nominal Coil Series RF310 B Y P A S S RF313 RF320 RF323 A T T E N U A T O R 5 50 12 390 5 100 12 850 5 50 12 390 5 100 12 850 3 3 3 3 DC-1 1-2 2-3 DC-1 1-2 2-3 DC-1 1-2 2-3 DC-1 1-2 2-3 © 2008 Teledyne Relays N.O N.C 1.1 : 1 1.1 : 1 1.3 : 1 1.1 : 1 1.1 : 1 1.3 : 1 1.2 : 1 1.3 : 1 1.3 : 1 1.2 : 1 1.3 : 1 1.2 : 1 1.2 : 1 1.1 : 1 1.1 : 1 1.1 : 1 1.2 : 1 1.1 : 1 1.1 : 1 1.1 : 1 1.3 : 1 1.1 : 1 1.1 : 1 1.3 : 1 Frequency Voltage Resistance Max Range (Vdc) (Ω) (GHz) (GHz) 5 50 DC-1 12 390 1-2 A150 3 15 610 2-3 26.5 1560 5 50 DC-1 12 390 1-2 A152 5 15 610 2-3 26.5 1560 3-5 RF310 VSWR Voltage Resistance Max Range (Vdc) (Ω) (GHz) (GHz) Nominal Coil Series Frequency Isolation Pole to Across N.O N.C Pole Contacts (dB) (dB) (dB) (dB) 35 27 0.1 0.2 30 24 0.2 0.3 21 22 0.3 0.4 35 27 0.1 0.2 30 24 0.2 0.3 21 22 0.3 0.3 33 27 0.2 0.1 28 23 0.4 0.1 26 20 0.5 0.3 33 27 0.3 0.1 28 23 0.4 0.2 26 20 0.5 0.3 Insertion Loss (dB) VSWR Attenuated Path Typ. Max. Insertion Loss Through Path Typ. Max. Typ. Max. 1.20 : 1 1.30 : 1 1.25 : 1 1.10 : 1 1.20 : 1 1.35 : 1 1.20 : 1 1.25 : 1 0.1 0.2 0.25 0.35 1.40 : 1 1.45 : 1 1.25 : 1 1.30 : 1 0.3 0.55 1.20 : 1 1.30 : 1 1.40 : 1 1.25 : 1 1.10 : 1 1.20 : 1 1.35 : 1 1.20 : 1 1.25 : 1 1.45 : 1 1.25 : 1 1.30 : 1 See Datasheet 0.1 0.2 0.3 0.25 0.35 0.55 RF320 SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE A150 Page 5 Established Reliability T²R Relays Selection Matrix Series ER114 ER114D ER114 DPDT - Non-Latching ER114DD ER116C ER134 ER134D ER134DD ER134 ER136C SPDT - Non-Latching DPDT - Non-Latching ER411D ER411 ER411D ER411DD ER411T ER412 ER412D ER412DD ER412T Nominal Voltage (Vdc) 5, 6, 9, 12, 18, 26.5 5, 6, 9, 12, 18, 26.5 5, 6, 9, 12, 18, 26.5 5, 6, 9, 12, 18, 26.5 5, 6, 9, 12, 18, 26.5 5, 6, 9, 12, 18, 26.5 5, 6, 9, 12, 18, 26.5 5, 6, 9, 12, 18, 26.5 5, 6, 9, 12, 18, 26.5 5, 6, 9, 12, 18, 26.5 5, 6, 9, 12, 18, 26.5 5, 6, 9, 12, 18, 26.5 5, 6, 9, 12, 18, 26.5 5, 6, 9, 12, 18, 26.5 5, 6, 9, 12, 18, 26.5 5, 6, 9, 12, 18, 26.5 Nominal Coil Typical Resistance Operating (Ω) Power (mW) 50, 98, 220, 450 390, 880, 1560 50, 98, 220, 450 390, 880, 1560 39, 78, 220, 450 390, 880, 1560 39, 78, 220, 450 390, 880, 1560 100, 200, 400, 200 800, 1600, 3200 100, 200, 400, 200 800, 1600, 3200 64, 125, 400, 200 800, 1600, 3200 100, 200, 400 200 800, 1600, 3200 63, 125, 280, 300 500, 1130, 2000 63, 125, 280, 300 500, 1130, 2000 50, 98, 280, 300 500, 1130, 2000 63, 125, 280, 300 500, 1130, 2000 50, 98, 220, 450 390, 880, 1560 50, 98, 220, 450 390, 880, 1560 39, 78, 220, 450 390, 880, 1560 50, 98, 220, 450 390, 880, 1560 ER412 Page 6 (800) 284-7007 • www.teledynerelays.com ♦ +44 (0) 1236 453124 • www.teledyne-europe.com © 2008 Teledyne Relays Established Reliability T²R Relays Selection Matrix Series SPDT - Latching ER421 ER421D ER421DD ER420 ER420D DPDT - Latching ER420DD ER422 ER422D ER422DD SPDT - Non-Latching ER431 ER431D ER431DD ER431T DPDT - Non-Latching ER432 ER432D ER432DD ER432T Nominal Voltage (Vdc) 5, 6, 9, 12, 18, 26.5 5, 6, 9, 12, 18, 26.5 5, 6, 9, 12, 18, 26.5 5, 6, 9, 12, 18, 26.5 5, 6, 9, 12, 18, 26.5 5, 6, 9, 12, 18, 26.5 5, 6, 9, 12, 18, 26.5 5, 6, 9, 12, 18, 26.5 5, 6, 9, 12, 18, 26.5 5, 6, 9, 12, 18, 26.5 5, 6, 9, 12, 18, 26.5 5, 6, 9, 12, 18, 26.5 5, 6, 9, 12, 18, 26.5 5, 6, 9, 12, 18, 26.5 5, 6, 9, 12, 18, 26.5 5, 6, 9, 12, 18, 26.5 5, 6, 9, 12, 18, 26.5 DPDT = Double-Pole, Double-Throw SPDT = Single-Pole, Double-Throw © 2008 Teledyne Relays Nominal Coil Typical Resistance Operating (Ω) Power (mW) 61, 120, 280, 290 500, 1130, 2000 61, 120, 280, 290 500, 1130, 2000 48, 97, 280, 290 500, 1130, 2000 61, 120, 280, 290 500, 1130, 2000 61, 120, 280, 290 500, 1130, 2000 48, 97, 280, 290 500, 1130, 2000 61, 120, 280, 290 500, 1130, 2000 61, 120, 280, 290 500, 1130, 2000 48, 97, 280, 290 500, 1130, 2000 125, 255, 630, 150 1025, 2300, 4000 125, 255, 630, 150 1025, 2300, 4000 100, 200, 630, 150 1025, 2300, 4000 125, 255, 630, 150 1025, 2300, 4000 100, 200, 400, 200 850, 1600, 3300 100, 200, 400, 200 850, 1600, 3300 64, 125, 400, 200 850, 1600, 3300 100, 200, 400, 200 850, 1600, 3300 ER420 ER422 ER431D ER = Teledyne Relays Established Reliability T²R Program see Appendix B for more details. SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE Page 7 Military Qualified (JAN) Relays Selection Matrix QPL Number Series J114 J114 M39016/17 J114D M39016/18 DPDT - Non-Latching J114DD M39016/19 J116C M28776/6 J134 M39016/41 J134D M39016/42 J134DD M39016/43 J134 SPDT - Non-Latching J136C M28776/7 J411 M39016/7 J411D M39016/23 J411DD M39016/24 J411T M28776/5 J412 M39016/9 J412D M39016/15 J412D DPDT - Non-Latching J412DD M39016/20 J412T M28776/1 J255 M39016/45 Nominal Voltage (Vdc) 5, 6, 9, 12, 18, 26.5 5, 6, 9, 12, 18, 26.5 5, 6, 9, 12, 18, 26.5 5, 6, 9, 12, 18, 26.5 5, 6, 9, 12, 18, 26.5 5, 6, 9, 12, 18, 26.5 5, 6, 9, 12, 18, 26.5 5, 6, 9, 12, 18, 26.5 5, 6, 9, 12, 18, 26.5 5, 6, 9, 12, 18, 26.5 5, 6, 9, 12, 18, 26.5 5, 6, 9, 12, 18, 26.5 5, 6, 9, 12, 18, 26.5 5, 6, 9, 12, 18, 26.5 5, 6, 9, 12, 18, 26.5 5, 6, 9, 12, 18, 26.5 Nominal Coil Typical Resistance Operating (Ω) Power (mW) 50, 98, 220, 450 390, 880, 1560 50, 98, 220, 450 390, 880, 1560 39, 78, 220, 450 390, 880, 1560 39, 78, 220, 450 390, 880, 1560 100, 200, 400, 200 800, 1600, 3200 100, 200, 400, 200 800, 1600, 3200 64, 125, 400, 200 800, 1600, 3200 100, 200, 400 200 800, 1600, 3200 63, 125, 280, 300 500, 1130, 2000 63, 125, 280, 300 500, 1130, 2000 50, 98, 280, 300 500, 1130, 2000 63, 125, 280, 300 500, 1130, 2000 50, 98, 220, 450 390, 880, 1560 50, 98, 220, 450 390, 880, 1560 39, 78, 220, 450 390, 880, 1560 50, 98, 220, 450 390, 880, 1560 5, 6, 12, 26.5 45, 63, 254, 1000 550 J255 Page 8 (800) 284-7007 • www.teledynerelays.com ♦ +44 (0) 1236 453124 • www.teledyne-europe.com © 2008 Teledyne Relays Military Qualified (JAN) Relays Selection Matrix SPDT - Latching Series QPL Number J421 M39016/8 J421D M39016/27 J421DD M39016/28 J420 M39016/12 J420D M39016/29 DPDT - Latching J420DD M39016/30 J422 M39016/12 J422D M39016/29 J422DD M39016/30 SPDT - Non-Latching J431 M39016/10 J431D M39016/25 J431DD M39016/26 DPDT - Non-Latching J431T M28776/4 J432 M39016/11 J432D M39016/16 J432DD M39016/21 J432T M28776/3 DPDT = Double-Pole, Double-Throw SPDT = Single-Pole, Double-Throw © 2008 Teledyne Relays Nominal Voltage (Vdc) 5, 6, 9, 12, 18, 26.5 5, 6, 9, 12, 18, 26.5 5, 6, 9, 12, 18, 26.5 5, 6, 9, 12, 18, 26.5 5, 6, 9, 12, 18, 26.5 5, 6, 9, 12, 18, 26.5 5, 6, 9, 12, 18, 26.5 5, 6, 9, 12, 18, 26.5 5, 6, 9, 12, 18, 26.5 5, 6, 9, 12, 18, 26.5 5, 6, 9, 12, 18, 26.5 5, 6, 9, 12, 18, 26.5 5, 6, 9, 12, 18, 26.5 5, 6, 9, 12, 18, 26.5 5, 6, 9, 12, 18, 26.5 5, 6, 9, 12, 18, 26.5 5, 6, 9, 12, 18, 26.5 Nominal Coil Typical Resistance Operating (Ω) Power (mW) 61, 120, 280, 290 500, 1130, 2000 61, 120, 280, 290 500, 1130, 2000 48, 97, 280, 290 500, 1130, 2000 61, 120, 280, 290 500, 1130, 2000 61, 120, 280, 290 500, 1130, 2000 48, 97, 280, 290 500, 1130, 2000 61, 120, 280, 290 500, 1130, 2000 61, 120, 280, 290 500, 1130, 2000 48, 97, 280, 290 500, 1130, 2000 125, 255, 630, 150 1025, 2300, 4000 125, 255, 630, 150 1025, 2300, 4000 100, 200, 630, 150 1025, 2300, 4000 125, 255, 630, 150 1025, 2300, 4000 100, 200, 400, 200 850, 1600, 3300 100, 200, 400, 200 850, 1600, 3300 64, 125, 400, 200 850, 1600, 3300 100, 200, 400, 200 850, 1600, 3300 J421 J422D J431 JAN = Teledyne Relays Military Qualified Relays see Appendix B for more details. SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE Page 9 Commercial Relays Selection Matrix Nominal Voltage (Vdc) 5, 6, 9, S114 12, 18, 26.5 5, 6, 9, S114D 12, 18, 26.5 5, 6, 9, S114DD 12, 18, 26.5 5, 6, 9, S134 12, 18, 26.5 5, 6, 9, S134D 12, 18, 26.5 5, 6, 9, S134DD 12, 18, 26.5 S172 5, 12, 26.5 S172D 5, 12, 26.5 Series S172 Non-Latching Latching 122C DPDT 172 172D 172 Non-Latching 712 712D 712TN Latching Non-Latching 712 Page 10 722 722D 732 732D 732TN (800) 284-7007 • www.teledynerelays.com ♦ Nominal Coil Resistance (Ω) 50, 98, 220, 390, 880, 1560 50, 98, 220, 390, 880, 1560 39, 78, 220, 390, 880, 1560 100, 200, 400, 800, 1600, 3200 100, 200, 400, 800, 1600, 3200 64, 125, 400, 800, 1600, 3200 64, 400, 1600 64, 400, 1600 5, 6, 9, 48, 120, 280 12, 18, 26.5 500, 1130, 2000 5, 12, 26.5 5, 12, 26.5 5, 6, 9, 12, 18, 26.5 5, 6, 9, 12, 18, 26.5 5, 6, 9, 12, 18, 26.5 5, 6, 9, 12, 18, 26.5 5, 6, 9, 12, 18, 26.5 5, 6, 9, 12, 18, 26.5 5, 6, 9, 12, 18, 26.5 5, 6, 9, 12, 18, 26.5 64, 400, 1600 64, 400, 1600 50, 98, 220, 390, 880, 1560 50, 98, 220, 390, 880, 1560 50, 98, 220, 390, 880, 1560 61, 120, 280, 500, 1130, 2000 61, 120, 280, 500, 1130, 2000 100, 200, 400, 850, 1600, 3300 100, 200, 400, 850, 1600, 3300 100, 200, 400, 850, 1600, 3300 +44 (0) 1236 453124 • www.teledyne-europe.com Typical Operating Power (mW) 450 450 450 200 200 200 390 390 290 390 390 450 450 450 290 290 200 200 200 © 2008 Teledyne Relays Special Environmental Relays Selection Matrix Nominal Voltage (Vdc) 5, 6, 9, 12, 18, 26.5 Nominal Coil Typical Resistance Operating (Ω) Power (mW) 50, 98, 220, 450 390, 880, 1560 432H 5, 6, 9, 12, 18, 26.5 100, 200, 400, 850, 1600, 3300 422H 5, 6, 9, 12, 18, 26.5 422K 5, 6, 9, 12, 18, 26.5 Series High Temperature Non-Latching 412H Latching High Shock DPDT Non-Latching High Vibration 5, 6, 9, 12, 18, 26.5 5, 6, 9, 412V 12, 18, 26.5 5, 6, 9, 412DV 12, 18, 26.5 5, 6, 9, 412DDV 12, 18, 26.5 5, 6, 9, 432V 12, 18, 26.5 5, 6, 9, 432DV 12, 18, 26.5 412K DPDT = Double-Pole, Double-Throw SPDT = Single-Pole, Double-Throw 61, 120, 280, 500, 1130, 2000 61, 120, 280, 500, 1130, 2000 50, 80, 160, 300, 600, 1350 50, 70, 155, 235, 610, 1130 33, 44, 125, 215, 470, 1050 33, 44, 125, 215, 470, 1050 80, 120, 240, 480, 950, 1900 80, 120, 240, 480, 950, 1900 200 412H 290 290 500 620 620 620 422H 350 350 JAN = Teledyne Relays Military Qualified Relays see Appendix B for more details. 432DV © 2008 Teledyne Relays SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE Page 11 Teledyne Relays Part Numbering System RF Attenuator Relays A150 - 20 - 26 / S Q Relay Series Q = Solder-Coated Leads G = Gold-Plated Leads (RoHS Compliant) * Parts ordered without Suffix may be received with Solder-Coated or Gold-Plated leads. Attenuation Value (dB) S = 0.187” Leads No Suffix = 0.75” Leads Nominal Coil Voltage (26 = 26.5 V) RF Relays RF100 X - 26 / S Q Relay Series Q = Solder-Coated Leads G = Gold-Plated Leads (RoHS Compliant) Ground Pin Option (See Appendix A) * Parts ordered without Suffix may be received with Solder-Coated or Gold-Plated leads. * Not Applicable for GRF Relays S = 0.187” Leads No Suffix = 0.75” Leads * Not Applicable for GRF Relays Nominal Coil Voltage (26 = 26.5 V) T2R Established Reliability Relays ER 114 Y M4 - 26 A / S Established Reliability Designator Q Q = Solder-Coated Leads G = Gold-Plated Leads (RoHS Compliant) Relay Series * Parts ordered without Suffix may be received with Solder-Coated or Gold-Plated leads. Ground Pin Option (See Appendix A) Pad Option (See Appendix A) Nominal Coil Voltage (26 = 26.5 V) S = 0.187” Leads W = 1.5” Leads No Suffix = 0.75” Leads Screening and Reliability Level (See Appendix for Screening Options B) Military Qualified (JAN) Relays J 114 Z Military (JAN) Designator 26 P L P = 0.187” Leads W = 1.5” Leads No Suffix = 0.75” Leads Ground Pin Option (See Appendix A) Pad Option (See Appendix A) (800) 284-7007 • www.teledynerelays.com - Screening and Reliability Level (See Appendix for Screening Options B) Relay Series Page 12 M4 Nominal Coil Voltage (26 = 26.5 V) ♦ +44 (0) 1236 453124 • www.teledyne-europe.com © 2008 Teledyne Relays Teledyne Relays Part Numbering System Commercial Surface Mount Relays S114D - 26 / G Q = Solder-Coated Leads G = Gold-Plated Leads (RoHS Compliant) Relay Series * Surface Mount Relays are Solder-Coated by default Nominal Coil Voltage (26 = 26.5 V) Commercial Relays 172 X M4 - 26 / S Q Q = Solder-Coated Leads G = Gold-Plated Leads (RoHS Compliant) Relay Series * Parts ordered without Suffix may be received with Solder-Coated or Gold-Plated leads. Ground Pin Option (See Appendix A) Pad Option (See Appendix A) S = 0.187” Leads No Suffix = 0.75” Leads Nominal Coil Voltage (26 = 26.5 V) Special Environmental / HI-REL Relays 412DV Relay Series Ground Pin Option (See Appendix A) Pad Option (See Appendix A) X M - 26 / S G Q = Solder-Coated Leads G = Gold-Plated Leads (RoHS Compliant) * Parts ordered without Suffix may be received with Solder-Coated or Gold-Plated leads. S = 0.187” Leads W = 1.5” Leads No Suffix = 0.75” Leads Nominal Coil Voltage (26 = 26.5 V) If you don’t see what you’re looking for in this Selection Guide, contact us! © 2008 Teledyne Relays SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE Page 13 CERTIFICATE OF COMPLIANCE It is Hereby Stated and Certified That the Company (TELEDYNE RELAYS) complies with the Restrictions on Hazardous Substances (RoHS) Directives to the extent stated herein: Teledyne Relays does not use any of the Restricted Substances specified by the RoHS Directives (listed below) as components in TO-5 and Centigrid® Electromechanical Relay products, nor are these substances employed during any electromechanical relay manufacturing process: Lead Mercury Cadmium Hexavalent Chromium Polybrominated Biphenyls (PBB’s) Polybrominated Diphenyl Ethers (PBDE’s) However, upon request from the Customer, relay leads may be coated with solder, which contains 60% tin and 40% lead. www.teledynerelays.com (800) 284-7007 relays@teledyne.com Page 14 (800) 284-7007 • www.teledynerelays.com ♦ +44 (0) 1236 453124 • www.teledyne-europe.com © 2008 Teledyne Relays Appendix A: Spacer Pads Pad designation and bottom view dimensions Ø.150 Ø.150 [3.81] [3.81] (REF) (REF) Ø.150 [3.81] Ø.150 (REF) [3.81] (REF) Ø.150 Ø.150 [3.81] [3.81] Ø.150 (REF) (REF) Ø.150 [3.81] [3.81] (REF) (REF) “M4” Pad for TO-5 Height Dim H Dim H MAX MAX Dim H MAX Dim H MAX Dim H Dim H MAX MAX Dim H Dim H MAX MAX Dim H Dim H MAX MAX Dim H MAX Dim H MAX Dim H Dim H MAX MAX Dim H Dim H MAX MAX “M4” Pad for TO-5 Dim H Dim H MAX MAX Dim H MAX Dim H MAX .156 [3.96] (REF) .156 [3.96] (REF) .156 [3.96] (REF) .256 [6.5] (REF) .156 [3.96] (REF) .156 .156 [3.96] [3.96] (REF) .156 (REF) .156 [3.96] [3.96] (REF) (REF) .256 Pad for Centigrid® “M4” [6.5] .256 [6.5] (REF) .256 [6.5] (REF) .256 [6.5] (REF) (REF) .256 [6.5] (REF) .256 [6.5] (REF) .256 [6.5] (REF) “M9” Pad for Centigrid® Dim H Dim H MAX MAX Dim H Dim H MAX MAX Dim H Dim H MAX MAX For use with the following: ER411T ER412, ER412D, ER412DD 712, 712D, 712TN, RF300, RF310, RF320 ER420, ER422D, ER420DD, 421, ER421D, ER421DD, ER422, ER422D, ER422DD, 722, 722D, RF341 ER431T, ER432T, ER432, ER432D, ER432DD 732, 732D, 732TN, RF303, RF313, RF323 Dim. H Max. .295 (7.49) .300 (7.62) .305 (7.75) .400 (10.16) .410 (10.41) RF312 .350 (8.89) ER411, ER411D, ER411DD .295 (7.49) ER431, ER431D, ER431DD .400 (10.16) RF311 .300 (7.62) RF331 .410 (10.41) 172, 172D .305 (7.75) ER114, ER114D, ER114DD, J114, J114D, J114DD .300 (7.62) ER134, ER134D, ER134DD, J134, J134D, J134DD .400 (10.16) RF100 .315 (8.00) RF103 .420 (10.67) Dim H MAX Dim H MAX 122C, A152 .320 (8.13) Dim H Dim H MAX MAX Dim H Dim H MAX MAX ER116C, J116C .300 (7.62) ER136C, J136C .400 (10.16) RF180 .325 (8.25) A150 .305 (7.75) Notes: 1. Spacer pad material: Polyester film. 2. To specify an “M4” or “M9” spacer pad, refer to the mounting variants portion of the part numbering example in the applicable datasheet. 3. Dimensions are in inches (mm). 4. Unless otherwise specified, tolerance is ± .010 (.25). 5. Add 10 mΩ to the contact resistance shown in the datasheet. 6. Add 0.01 oz. (0.25 g) to the weight of the relay assembly shown in the datasheet. © 2008 Teledyne Relays SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE Page 15 Appendix A: Spreader Pads Pad designation and bottom view dimensions .370[9.4] [9.4] .370 MAX SQ SQ MAX .370[9.4] [9.4] .370 MAX SQ SQ MAX .370 .370[9.4] [9.4] MAX MAX SQ SQ .150 .150 [3.81] [3.81] .150 .150 [3.81] [3.81] .300 .300 [7.62] [7.62] .300 .300 [7.62] .150 [7.62] .150 [3.81] [3.81] .300 .300 [7.62] [7.62] .100 .100 [2.54] [2.54] .100 .100 [2.54] [2.54] .100 .100 [2.54] [2.54] .100 .100 [2.54] [2.54] .100 .100 [2.54] [2.54] .200 .200 [5.08] [5.08] .200 .200 [5.08] [5.08] .200 .200 [5.08] [5.08] .390 [9.91] .390 [9.91] SQ SQ .390[9.91] [9.91] .390 SQ SQ .100 .100 [2.54] [2.54] "M" Pad 5/ 6/ .390 .390[9.91] [9.91] SQ SQ .100 .100 [2.54] [2.54] .100 .100 [2.54] .300 [2.54] .300 [7.62] [7.62] .300 .100 .300 .100 [7.62] [2.54] [7.62] [2.54] .300 .300 [7.62] [7.62] .300 .300 [7.62] [7.62] .300 .3007/ 8/ "M2" Pad [7.62] [7.62] .370[9.4] [9.4] .370 MAX SQ SQ MAX .370[9.4] [9.4] .370 MAX SQ SQ MAX .370 .370[9.4] [9.4] MAX MAX SQ SQ .150 .150 [3.81] [3.81] .150 .150 [3.81] [3.81] .300 .300 [7.62] [7.62] .300 .300 [7.62] .150 [7.62] .150 [3.81] [3.81] .300 .300 [7.62] [7.62] .100 .100 .150 .150 [2.54] [2.54] [3.81] [3.81] .150 .150 [3.81] [3.81] .150 .150 [3.81] [3.81] .150 .150 [3.81] [3.81] .150 .150 [3.81] [3.81] .100 .100 [2.54] [2.54] .100 .100 [2.54] [2.54] .100 .100 [2.54] [2.54] .100 .100 [2.54] [2.54] .100 .100 [2.54] [2.54] .200 .200 [5.08] [5.08] .200 .200 [5.08] [5.08] .200 .200 [5.08] [5.08] Dim HH Dim MAX MAX Dim Dim HH MAX MAX For use with the following: .014 .014 [0.36] [0.36] .014 .014 (REF) (REF) [0.36] [0.36] (REF) (REF) .014 .014 [0.36] [0.36] (REF) (REF) Dim Dim HH MAX MAX .370 .370 [9.4] [9.4] .370 .370 MIN MIN [9.4] [9.4] MIN MIN .370 .370 [9.4] [9.4] MIN MIN .100 .100 [2.54] [2.54] .100 .100 [2.54] [2.54] .150 .150 [3.81] [3.81] .300 .300 [7.62] [7.62] Height .100 .100 [2.54] [2.54] Dim HH Dim MAX MAX Dim Dim HH MAX MAX ER411T, J411T, ER412, ER412D ER412DD, J412, J412D, J412DD ER412T, J412T 712, 712D, 712TN ER431T, J431T, ER432, ER432D ER432DD, J432, J432D, J432DD ER432T, J432T 732, 732D, 732TN .130 .130 [3.3] [3.3] .130 .130 [3.3] [3.3] .130 .130 [3.3] [3.3] H MAX MAX .014 .014 [0.36] [0.36] .014 .014 (REF) (REF) [0.36] [0.36] (REF) (REF) .014 .014 [0.36] [0.36] (REF) (REF) Dim Dim HH MAX MAX .370 .370 [9.4] [9.4] .370 .370 MIN MIN [9.4] [9.4] MIN MIN .370 .370 [9.4] [9.4] MIN MIN "M3" Pad 5/ 6/ 9/ .393 (9.99) .493 (12.52) .503 (12.78) .398 (10.11) ER411T ER412, ER412D, ER412DD J412, J412D, J412DD .441 (11.20) 732, 732D Dim HH Dim MAXH MAX Dim Dim .388 (9.86) ER420, J420, ER420D, J420D ER420DD, J420DD, ER421, J421 ER421D, J421D, ER421DD J422D, ER422DD, J422DD, 722 712, 712D ER421, ER421D, ER421DD 722, 732D ER431T ER432, ER432D, ER432DD Dim Dim HH MAX MAX Dim. H Max. ER411, ER411D, ER411DD ER411TX ER412X, ER412DX, ER412DDX ER412TX 712X, 712DX, 712TNX ER420X, ER420DX, ER420DDX ER421X, ER421DX, ER421DDX ER422X, ER422DX ER422DDX, 722X, 722DDX ER431, ER431D, ER431DD ER431TX ER432X, ER432DX, ER432DDX ER432TX 732X, 732DX, 732TNX .451 (11.46) .451 (11.46) .546 (13.87) .556 (14.12) .388 (9.86) .393 (9.99) .398 (10.11) .493 (12.52) .503 (12.78) Notes: 1. Spreader pad material: Diallyl Phthalate. 2. To specify an “M”, “M2” or “M3” spreader pad, refer to the mounting variants portion of the part number example in the applicable datasheet. 3. Dimensions are in inches (mm). 4. Unless otherwise specified, tolerance is ± .010” (0.25). 5/. Add 25 mΩ to the contact resistance shown in the datasheet. 6/. Add .01 oz. (0.25 g) to the weight of the relay assembly shown in the datasheet. 7/. Add 50 mΩ to the contact resistance shown in the datasheet. 8/. Add 0.025 oz (0.71 g) to the weight of the relay assembly shown in the datasheet. 9/. M3 pad to be used only when the relay has a center pin (e.g. ER411M3-12A, 722XM3-26.) Page 16 (800) 284-7007 • www.teledynerelays.com ♦ +44 (0) 1236 453124 • www.teledyne-europe.com © 2008 Teledyne Relays .050 [1.27] .050 [1.27] "X" POSITION "X" POSITION Appendix A: Ground Pin Positions "U" POSITION "U" POSITION .100 [2.54] Ø.200 [Ø5.08] Ø.200 [Ø5.08] .100 [2.54] .100 [2.54] 36°±3° .100 [2.54] (ER116C and ER136C (ER116C andonly) ER136C only) "Z" POSITION "Z" POSITION "X" POSITION "X" POSITION "Y" POSITION "Y" POSITION "Y" POSITION 36°±3° "Z" POSITION "Z" POSITION Ø.200 [Ø5.08] LEGEND: 45°±3° "Y" 45°±3° Ø.200 [Ø5.08] POSITION "Y" POSITION Glass Insulated Lead position "Z" POSITION TO-5 Relays: ER411T, ER412, ER412T, ER420, ER421, ER422, ER431T, ER432, ER432T, 712, 712TN, 400H, 400K, 400V, RF300, RF303, RF341, RF312, RF310, RF313, RF320, RF323 TO-5 Relays: Ground PinER431, position ER411, RF311, RF331 Either Ground Pin or Insulated Lead position depending on Relay type .100 [2.54] "Y" .100 [2.54] "W" "Z" .100 [2.54] .050 [1.27] "X" [Ø5.08] ON ITION ON ON POSITION "X" POSITION (ER116C and ER136C only) [2.54] Insulated Lead position lead position Indicates ground pin or lead position Either Ground PinPOSITION or type depending on"Y" Relay Ground Pin position depending on position relay type Insulated Lead depending on Relay Either Ground Pin or type Insulated Lead position on Relay type © 2008 Teledynedepending Relays POSITION "Y" POSITION "W" POSITION Ø.200 [Ø5.08] position Glass Insulated Lead LEGEND: position Indicates Ground Pinground positionpin position 36°±3° "Z" .100 [2.54] Centigrid® Relays: RF100, RF103, ER114, ER134, 172 .100"Z" POSITION POSITION Glass Insulated Lead Ground Pinglass position Indicates insulated Either Ground Pin or position POSITION .100 [2.54] POSITION LEGEND: Glass Insulated Lead ITION "Y" POSITION Centigrid® Relays: RF180, ER116C, 122C, ER136C "Z" POSITION LEGEND: .100 [2.54] "U" .100 [2.54] ON Ø.200 POSITION 45°±3° "Z" POSITION NOTES.100 [2.54] 1. Terminal views shown 2. Dimensions are in inches (mm) .050 [1.27] "X" POSITION 3. Tolerances: ± .010 (±.25) unless otherwise specified 4. Ground pin positions are within .015 (0.38) dia. of true position "Y" dia., POSITION 5. Ground pin head 0.035 (0.89) ref: height 0.010 (0.25) ref. "U" POSITION 6. Lead dia. 0.017 (0.43) nom. .100 [2.54] SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE (ER116C and ER136C only Page 17 Appendix B: Teledyne Relays T2R Program Teledyne Relays’ program was developed to provide the JAN relay user an alternate means of specifying and procuring relay is the same as that of its JAN counterpart. program established reliability relays. The form, fit and function of a requirements differ in certain regimens/tests found in both MIL-PRF-28776 and MIL-PRF-39016 that add cost but no value to the relay. This program parallels the military specifications in most aspects. The components that make up such a program are intricate and varied. It is very difficult to detail on a one-to-one basis how the two programs differ. The following page presents a table that compares the 100% screening performed on JAN relays and relays prior to shipment. Other significant highlights of the program include: • Two unique screening levels • The ability to define lead finish • Spacer pad options not allowed by the military specifications • Ground pin options not allowed by the military specifications • Reduced lead time • Reduced cost The program is fully defined for both general product requirements and detailed product requirements in the following Teledyne Relays specifications: TR-R-1 TR-STD-1 TR-STD-2 TR-ERL-1 TR-R-1/XXX TR Supplement Copies of these documents are available from Teledyne Relays. We suggest that users check with Teledyne Relays from time to time to assure that they have the latest issue. Can’t Find What You Need? Check out our full line of relays and switches. Order literature online at http://www.teledynerelays.com/litrequest.asp Page 18 (800) 284-7007 • www.teledynerelays.com ♦ +44 (0) 1236 453124 • www.teledyne-europe.com © 2008 Teledyne Relays Appendix B: Teledyne Relays T2R Program Screening Levels Applicable To INSPECTION A Level 1.5%/10K Cycles B Level .75%/10K Cycles JAN L Level 3%/10K Cycles JAN M Level 1%/10K Cycles X X X X Subgroup 1 Screening, Internal Moisture AQL Vibration (Sinusoidal) AQL X Vibration (Sinusoidal) 100% X Screening, Burn-In (Hybrids only) X X X X X X Screening, Run-In (Room Temperature) X X Screening, Run-In (+125°C and –65°C) Subgroup 2 Coil Resistance or Coil Current X X X X Insulation Resistance X X X X Dielectric Withstanding Voltage X X X X Static Contact Resistance X X X X Pickup and Dropout or Set and Reset Voltage X X X X Operate and Release or Set and Reset Time X X X X X X X X Hold Voltage Turn-On and Turn-Off Time (Hybrids only) X Contact Bounce Time X Contact Stabilization Time X X X X Turn-On Current (T Hybrids only) X X X X Turn-On voltage (C Hybrids only) X X X X Turn-Off Voltage (Hybrids only) X X X X Coil Transient Suppression (D, DD and Hybrids only) X X X X Diode Blocking Integrity (DD only) X X X X Zener Voltage (C Hybrid only) X X X X Neutral Screen (Latching Relays only) X X X X Break Before Make Verification X X Contact Simultaneity X X Subgroup 3 Solderability 2 Samples per Daily Solderability Inspection Lot X X X X Leak Test X X X X External Visual and Mechanical Inspection 2/Lot for Dimension and Weight Check X X X X © 2008 Teledyne Relays SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE Page 19 Appendix: Teledyne Relays HI-REL Program Teledyne Relays: Because in deep space there is no acceptable failure rate Teledyne Relays has a long history of supplying High Reliability relays for use in space bound vehicles. From the earliest deep space probes, such as Voyager I, now nearing 10 billion miles out in space, to the next generation of probes scheduled for the future , Teledyne Relays continues to be the preeminent supplier of Hi-Reliability relays to the space market. Relay Types TO-5 Magnetic-Latching Relays TO-5 Non-Latching Relays TO-5 Magnetic-Latching, High-Shock Relays TO-5 Non-Latching, High-Shock Relays TO-5 Non-Latching, High-Vibration Relays Hi-Rel Screening Capabilities 100% Open Electrical Inspection 100% Precap Inspection Fully Automated Small Particle Inspection (Millipore Clean) Asynchronous Miss Test Coil Continuity Sine Vibration Random Vibration High/Low Run In (Miss Test) –65 ºC ± 125 ºC Radiographic Inspection Mechanical Shock Test Thermal Shock Test Teledyne Screening Document 0-40-837 NASA approved screening regimen based on NASA/GSFC Acceleration Radiographic Inspection (X-ray) S-311-P.754 Mechanical Shock Test Thermal Shock Test Acceleration Load Banks for a Variety of Life Test Load Serialized Printed Electrical Data Continuous Life Testing Environmental Testing Vertical Integration Teledyne Relays Hi-Reliability Specification: TR-HIREL-1 • Eliminates the need for customers to develop and maintain specifications. • Manufacturing and Quality Assurance requirements are fully defined and documented. • Meets the general requirements of both ESA/SCC and NASA/GSFC documents. • Offers options for 100% Group A screening • Offers options for 3 levels of Lot Acceptance Testing (LAT). For information or answers to your questions, contact Dan Yracheta, Program Manager, at (323) 241-1218 or dyracheta@teledyne.com. Page 20 (800) 284-7007 • www.teledynerelays.com ♦ +44 (0) 1236 453124 • www.teledyne-europe.com © 2008 Teledyne Relays Authorized Distributors NORTH AMERICA ALLIED ELECTRONICS Tel: (800) 433-5700 www.alliedelec.com/search.asp FINLAND ARROW Finland Oy Tel: +358 9 4766 6396 www.arrowne.com ASAP ELECTRONICS Tel: (800) 477-1272 www.asapelectronics.com FRANCE ARROW France Tel: +33 1 4180 8424 E-mail: ralves@arrowfrance.com AVNET Tel: (800) 772-8638 www.em.avnet.com CCA-WESCO (Solid State Relays Only) Tel: (508) 870-5000 www.cca-corp.com MASTER DISTRIBUTORS Tel: (888) 473-5297 www.onlinecomponents.com MOUSER ELECTRONICS Tel: (800) 346-6873 www.mouser.com RICHARDSON ELECTRONICS Tel: (800) 737-6937 www.rell.com SHERBURN ELECTRONICS Tel: (800) 366-3066 www.sherburn.com INTERNATIONAL RICHARDSON ELECTRONICS Tel: (800) 737-6937 www.rell.com BELGIUM & LUXEMBOURG Nijkerk Electronics nv Tel: +32 (0) 3 544 7066 E-mail: peter.vanhal@nijkerk.be www.nijkerk-ne.com CANADA Cee-Jay Microsystems Tel: (613) 599-5626 www.cjmicro.com CHINA & HONG KONG El-Pax, Inc. USA Head Office Tel: 650-692-8896 E-mail: elpax@fiaco.com Beijing Office Tel: 86-10-6503-2171 E-mail: beijing@fiaco.com CZECH REPUBLIC Amtek spol. s.r.o. Tel: +420 547 125 555 E-mail: amtek@amtek.cz www.amtek.cz DENMARK ARROW Denmark A/S Tel: +45 (0) 70102211 E-mail: jbh@arrownordic.com www.arrowne.com ESTONIA ARROW Estonia Tel: +372 6 774250 E-mail: estonia@arrownordic.com www.arrowne.com © 2008 Teledyne Relays GERMANY Adelco Elektronik GmbH Tel: +49 (0) 4106 61040 E-mail: adelco@t-online.de www.adelco-elektronik.de Hot Electronic GmbH Tel:+49 (0) 89 666 2836 E-mail: info@hot-electronic.de www.hot-electronic.de MRC Components oHG Tel: +49 (0) 8161 98480 E-mail: info@mrccomponents.de www.mrccomponents.de Zettler electronics GmbH Tel: +49 (0) 89 800 97-0 E-mail: office@zettlerelectronics.com www.zettlerelectronics.com INDIA Specsynergy Technologies, Inc. San Jose, CA (Main Office) Tel: (408) 954-8474 x105 E-mail: karthik@spectraus.com Specsynergy Technologies, Inc. New Delhi Office Tel: 91 11 25860 752 E-mail: malik@specsynergytech.com ISRAEL STG International Ltd. Tel: +972 (0) 3 733 1400 E-mail: davidb@stggroup.co.il www.stggroup.co.il ITALY SINCRON s.r.l. Tel: +39 02 95384218 E-mail: ermanno.baschieri@sincron.it www.sincron.it JAPAN Comcraft Corporation Tokyo Tel: 81-3-3395-5553 E-mail: trcsales@comcraft.co.jp www.comcraft.co.jp Comcraft Corporation Osaka Tel: 81-6-6396-7722 E-mail: trcsales@comcraft.co.jp www.comcraft.co.jp KOREA Electro-Comm USA Tel: (323) 254-7790 E-mail: briansong@anyeparts.com www.anyeparts.com Electro-Comm SEOUL Tel: 82-31-713-4216 E-mail: tony_jang@anyeparts.com www.anyeparts.com LATVIA ARROW Latvia Tel: +371 7311490 E-mail: latvia@arrownordic.com http:www.arrowne.com LITHUANIA ARROW Lithuania Tel: +370-37-759015 E-mail: lithuania@arrownordic.com http:www.arrowne.com MALAYSIA Device Electronics PTE, Ltd. Tel: (603) 7880 8626/8636 E-mail: ngthomas@devicelect.com NETHERLANDS Nijkerk Electronics B.V. Tel: +32 (0) 3 544 7066 E-mail: peter.vanhal@nijkerk.be www.nijkerk-ne.com NORWAY ARROW Norway A/S Tel: +47 (0) 21306532 stondevoldshagen@arrownordic.com www.arrowne.com POLAND Zettler electronics Poland sp.z.o.o. Tel: +48 (0) 68 4791438 E-mail: office@zettlerelectronics.pl www.zettlerelectronics.pl RUSSIA Petersburg Electronic Company JSC Tel: +7 812 4488 777 e-mail: dkizha@pec.spb.ru www.pec.spb.ru SINGAPORE Device Electronics PTE, Ltd. Tel: 65-288 6455 E-mail: ngthomas@devicelect.com SWEDEN OEM Electronics Tel: +46 75 242 4562 E-mail: ulf.nygren@oemelectronics.se www.oemelectronics.se SWITZERLAND ENA AG Tel: +41 56 6342834 E-mail: rolf.hochstrasser@ena.ch www.ena.ch TAIWAN Bright Toward Industrial Co., Ltd. Tel: +886-2-822-76000 E-mail: philip@relays.com.tw www.relays.com.tw UNITED KINGDOM Arrow Electronics UK Ltd. Tel: +44 (0) 1279 626 777 www.arrowne.com Willow Technologies Ltd. Tel: +44 (0) 1342 835 234 E-mail: sales@willow.co.uk www.willow.co.uk 2001 Electronic Components Ltd. Tel: +44 (0) 1438 742 001 E-mail: sales@2001elec.co.uk www.2001elec.co.uk SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE Page 21 HEADQUARTERS 12525 Daphne Ave. Hawthorne, CA 90250 Phone: (323) 777-0077 or (800) 284-7007 Fax: (323) 241-1287 E-mail: relays@teledyne.com www.teledynerelays.com EUROPE 9-13 Napier Road Wardpark North Cumbernauld G68 OEF Scotland UK Phone: +44 (0) 1236 453 124 Fax: +44 (0) 1236 780 651 E-mail: sales_europe@teledyne.com www.teledyne-europe.com PRINTED IN U.S.A. TR0408