Teledyne relays - Richardson RFPD

advertisement
Electromechanical Relays
Selection Guide
Latching
Non-Latching
JAN
Commercial
RF
Established
Reliability
Surface-Mount
Environmental
Attenuated
Switching Solutions
Teledyne Relays has been the world’s innovative leader
in manufacturing ultraminiature, hermetically sealed,
electromechanical and solid-state switching products
for more than 40 years. The company’s comprehensive
product line meets a wide range of requirements for
defense and aerospace, industrial, commercial, medical
and RF & wireless uses.
Business Focus
• MIL QPL & COTS Solid-State Relays
• MIL QPL & COTS Electromechanical Relays
• HiRel (Space) Electromechanical Relays
• RF & Microwave Relays & Coaxial Switches
• Industrial Solid-State Relays
• Switching Matrices
Markets
• Commercial & Military Aviation
• Defense & Aerospace
• Telecom/Communications (Wireless)
• Instrumentation & Test
• Industrial Power & Motion Control
• Medical Applications
Teledyne Relays offer superior signal integrity
up to 12 Gbps. See the RF relays section in our
website.
(800) 284-7007 • www.teledynerelays.com
♦
Product Assurance
Under an aggressive Total Quality Management (TQM)
program, Teledyne Relays has embraced a “continuous
improvement” culture. With recognized certifications such
as AS/EN/JISQ 9100 - Revision B and ISO 9001:9002,
DSCC MIL-STD-790 and Boeing D6-82479 Appendix
A, Teledyne Relays has become a primary supplier of
switching solutions with the highest quality and reliability
to industry leaders around the world.
Technical Service & Customer Support
Teledyne Relays provides easy access to technical
service and customer support. Our websites make it easy
to find technical information, buy products and even get
e-mail responses within 24 hours. Switching solutions
are only a mouse click away at www.teledynerelays.com
or at teledyne-europe.com. Information about coax
switches is available at www.teledynecoax.com. An
online search function helps engineers locate specific
solid-state relays, electromechanical relays and coaxial
switches quickly by selecting parameters via drop-down
Parametric Search — The Teledyne Relays website allows
engineers to use drop-down menus to select relays and
switches based on various parameters.
+44 (0) 1236 453124 • www.teledyne-europe.com
© 2008 Teledyne Relays
RF
SWITCHING
SOLUTIONS
CCR-59 and CCR-33K Coaxial Switches
• DC to 33 GHz
• Excellent insertion loss repeatability
• Ultra low passive intermodulation (PIM)
• 5 million cycles characteristic life
• Failsafe and latching
GRF312 Surface-Mount Relays
• DC to 8GHz
• Signal Integrity measured to 12 Gbps
• Excellent pole-to-pole Isolation
• Pick-and-place surface mount solution
• Hermetically sealed - immune to cleaning solutions
(800) 351-7368 • www.teledynecoax.com
(800) 596-3855 • www.teledynerelays.com
© 2008 Teledyne Relays
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE
Page 1
RF Relays Selection Matrix
Nominal Coil
D
P
D
T
N
O
N
L
A
T
C
H
I
N
G
Isolation
Pole to Across Insertion
Series
Voltage Resistance Max Range VSWR
Pole Contacts Loss (dB)
(Vdc)
(Ω)
(GHz) (GHz)
(dB)
(dB)
5
50
DC-1 1.1 : 1
40
30
0.1
RF100
12
390
1-2
1.2 : 1
35
25
0.3
3
5
100
RF103
2-3
1.5 : 1
33
22
0.5
12
800
5
50
DC-1 1.1 : 1
50
34
0.2
GRF100
1-2
1.1 : 1
45
27
0.2
12
390
2-3
1.1 : 1
55
27
0.3
6
5
100
3-4
1.2 : 1
38
28
0.4
GRF103
4-5
1.5 : 1
40
26
0.7
12
800
5-6
1.8 : 1
38
24
1.1
5
50
DC-1 1.1 : 1
35
35
0.2
SGRF100
1-2
1.2 : 1
30
30
0.3
12
390
2-3
1.2 : 1
29
29
0.5
6
5
100
3-4
1.3 : 1
28
27
0.7
SGRF103
4-5
1.6 : 1
27
25
0.9
12
800
5-6
1.7 : 1
25
25
1.0
5
64
DC-1 1.1 : 1
50
35
0.1
GRF172
12
400
2.5
1-2
1.2 : 1
43
27
0.2
26.5
1600
2-3
1.1 : 1
50
25
0.2
5
50
DC-1 1.1 : 1
38
30
0.1
RF300
12
390
1-2
1.1 : 1
30
24
0.2
3
5
100
RF303
2-3
1.2 : 1
25
22
0.3
12
850
5
50
DC-1 1.1 : 1
46
32
0.1
GRF300
1-2
1.1 : 1
42
30
0.2
12
390
2-3
1.1 : 1
40
30
0.2
6
5
100
3-4
1.2 : 1
38
30
0.4
GRF303
4-5
1.3 : 1
35
28
0.8
12
850
5-6
1.4 : 1
30
25
0.9
GRF100
Page 2
Frequency
SGRF103
(800) 284-7007 • www.teledynerelays.com
♦
GRF172
+44 (0) 1236 453124 • www.teledyne-europe.com
GRF300
© 2008 Teledyne Relays
RF Relays Selection Matrix
Nominal Coil
Series
SGRF300
SGRF303
D
P
D
T
N
O
N
L
A
T
C
H
I
N
G
Voltage Resistance Max Range VSWR
(Vdc)
(Ω)
(GHz) (GHz)
5
50
12
390
5
100
12
850
5
50
RF312
N
O
N
L
A
T
C
H
RF311
RF331
6
8
12
390
5
50
GRF312
S
P
D
T
Frequency
8
12
390
5
12
63
500
26.5
2000
5
12
125
1025
26.5
4000
8
DC-1
1-2
2-3
3-4
4-5
5-6
DC-1
1-2
2-3
3-4
4-5
5-6
6-7
7-8
DC-1
1-2
2-3
3-4
4-5
5-6
6-7
7-8
DC-1
1-2
2-3
3-4
4-5
5-6
6-7
7-8
1.1 : 1
1.1 : 1
1.1 : 1
1.1 : 1
1.1 : 1
1.4 : 1
1.1 : 1
1.1 : 1
1.1 : 1
1.1 : 1
1.1 : 1
1.1 : 1
1.2 : 1
1.3 : 1
1.1 : 1
1.1 : 1
1.1 : 1
1.1 : 1
1.1 : 1
1.2 : 1
1.4 : 1
1.8 : 1
1.1 : 1
1.2 : 1
1.4 : 1
1.5 : 1
1.3 : 1
1.4 : 1
1.6 : 1
1.5 : 1
Isolation
Pole to Across Insertion
Pole Contacts Loss (dB)
(dB)
(dB)
43
33
0.2
40
38
0.2
45
35
0.3
28
44
0.6
23
35
0.7
18
32
0.8
45
30
0.1
35
24
0.2
30
22
0.3
38
27
0.4
26
32
0.5
25
40
0.6
23
25
0.7
22
24
0.8
70
40
0.1
65
32
0.2
50
34
0.3
35
38
0.4
35
42
0.6
38
33
0.4
40
28
0.7
42
28
1.3
38
0.1
32
0.2
27
0.3
23
0.3
20
0.4
20
0.5
17
0.7
17
0.8
GRF312
© 2008 Teledyne Relays
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE
SGRF303
Page 3
RF Relays Selection Matrix
Nominal Coil
Series
S
P
D
T
N
O
N
L
A
T
C
H
GRF311
RF180
D
P
D
T
L
A
T
C
H
I
N
G
GRF180
Frequency
Voltage Resistance Max Range VSWR
(Vdc)
(Ω)
(GHz) (GHz)
5
63
12
500
26.5
2000
5
61
12
500
26.5
2000
5
61
12
500
26.5
2000
5
61
8
6
6
GRF342
S
P
D
T
L
A
T
C
H
RF341
6
12
500
5
61
12
500
26.5
2000
6
(800) 284-7007 • www.teledynerelays.com
1.1 : 1
1.2 : 1
1.3 : 1
1.4 : 1
1.4 : 1
1.4 : 1
1.5 : 1
1.5 : 1
1.1 : 1
1.1 : 1
1.2 : 1
1.2 : 1
1.4 : 1
2.2 : 1
1.1 : 1
1.1 : 1
1.2 : 1
1.2 : 1
1.5 : 1
2.1 : 1
1.1 : 1
1.1 : 1
1.2 : 1
1.1 : 1
1.1 : 1
1.4 : 1
1.1 : 1
1.1 : 1
1.1 : 1
1.1 : 1
1.2 : 1
1.3 : 1
GRF180
GRF311
Page 4
DC-1
1-2
2-3
3-4
4-5
5-6
6-7
7-8
DC-1
1-2
2-3
3-4
4-5
5-6
DC-1
1-2
2-3
3-4
4-5
5-6
DC-1
1-2
2-3
3-4
4-5
5-6
DC-1
1-2
2-3
3-4
4-5
5-6
Isolation
Pole to Across Insertion
Pole Contacts Loss (dB)
(dB)
(dB)
42
0.1
32
0.2
27
0.3
27
0.4
26
0.5
23
0.7
19
1.0
19
1.2
55
40
0.1
52
35
0.2
50
30
0.3
45
29
0.3
32
28
0.7
30
26
1.2
55
45
0.1
50
36
0.1
40
35
0.2
35
31
0.4
30
30
0.8
25
29
1.3
50
35
0.2
43
35
0.2
35
34
0.3
30
30
0.4
28
29
0.5
27
27
0.7
40
0.2
35
0.3
30
0.5
27
0.6
25
0.8
24
1.5
♦
+44 (0) 1236 453124 • www.teledyne-europe.com
GRF342
© 2008 Teledyne Relays
RF Relays Selection Matrix
Nominal Coil
Series
RF310
B
Y
P
A
S
S
RF313
RF320
RF323
A
T
T
E
N
U
A
T
O
R
5
50
12
390
5
100
12
850
5
50
12
390
5
100
12
850
3
3
3
3
DC-1
1-2
2-3
DC-1
1-2
2-3
DC-1
1-2
2-3
DC-1
1-2
2-3
© 2008 Teledyne Relays
N.O
N.C
1.1 : 1
1.1 : 1
1.3 : 1
1.1 : 1
1.1 : 1
1.3 : 1
1.2 : 1
1.3 : 1
1.3 : 1
1.2 : 1
1.3 : 1
1.2 : 1
1.2 : 1
1.1 : 1
1.1 : 1
1.1 : 1
1.2 : 1
1.1 : 1
1.1 : 1
1.1 : 1
1.3 : 1
1.1 : 1
1.1 : 1
1.3 : 1
Frequency
Voltage Resistance Max Range
(Vdc)
(Ω)
(GHz) (GHz)
5
50
DC-1
12
390
1-2
A150
3
15
610
2-3
26.5
1560
5
50
DC-1
12
390
1-2
A152
5
15
610
2-3
26.5
1560
3-5
RF310
VSWR
Voltage Resistance Max Range
(Vdc)
(Ω)
(GHz) (GHz)
Nominal Coil
Series
Frequency
Isolation
Pole to Across
N.O N.C
Pole Contacts
(dB) (dB)
(dB)
(dB)
35
27
0.1 0.2
30
24
0.2 0.3
21
22
0.3 0.4
35
27
0.1 0.2
30
24
0.2 0.3
21
22
0.3 0.3
33
27
0.2 0.1
28
23
0.4 0.1
26
20
0.5 0.3
33
27
0.3 0.1
28
23
0.4 0.2
26
20
0.5 0.3
Insertion
Loss (dB)
VSWR
Attenuated Path
Typ.
Max.
Insertion
Loss
Through Path
Typ.
Max.
Typ.
Max.
1.20 : 1
1.30 : 1
1.25 : 1 1.10 : 1 1.20 : 1
1.35 : 1 1.20 : 1 1.25 : 1
0.1
0.2
0.25
0.35
1.40 : 1
1.45 : 1 1.25 : 1 1.30 : 1
0.3
0.55
1.20 : 1
1.30 : 1
1.40 : 1
1.25 : 1 1.10 : 1 1.20 : 1
1.35 : 1 1.20 : 1 1.25 : 1
1.45 : 1 1.25 : 1 1.30 : 1
See Datasheet
0.1
0.2
0.3
0.25
0.35
0.55
RF320
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE
A150
Page 5
Established Reliability T²R Relays Selection Matrix
Series
ER114
ER114D
ER114
DPDT - Non-Latching
ER114DD
ER116C
ER134
ER134D
ER134DD
ER134
ER136C
SPDT - Non-Latching
DPDT - Non-Latching
ER411D
ER411
ER411D
ER411DD
ER411T
ER412
ER412D
ER412DD
ER412T
Nominal
Voltage
(Vdc)
5, 6, 9,
12, 18, 26.5
5, 6, 9,
12, 18, 26.5
5, 6, 9,
12, 18, 26.5
5, 6, 9,
12, 18, 26.5
5, 6, 9,
12, 18, 26.5
5, 6, 9,
12, 18, 26.5
5, 6, 9,
12, 18, 26.5
5, 6, 9,
12, 18, 26.5
5, 6, 9,
12, 18, 26.5
5, 6, 9,
12, 18, 26.5
5, 6, 9,
12, 18, 26.5
5, 6, 9,
12, 18, 26.5
5, 6, 9,
12, 18, 26.5
5, 6, 9,
12, 18, 26.5
5, 6, 9,
12, 18, 26.5
5, 6, 9,
12, 18, 26.5
Nominal Coil
Typical
Resistance
Operating
(Ω)
Power (mW)
50, 98, 220,
450
390, 880, 1560
50, 98, 220,
450
390, 880, 1560
39, 78, 220,
450
390, 880, 1560
39, 78, 220,
450
390, 880, 1560
100, 200, 400,
200
800, 1600, 3200
100, 200, 400,
200
800, 1600, 3200
64, 125, 400,
200
800, 1600, 3200
100, 200, 400
200
800, 1600, 3200
63, 125, 280,
300
500, 1130, 2000
63, 125, 280,
300
500, 1130, 2000
50, 98, 280,
300
500, 1130, 2000
63, 125, 280,
300
500, 1130, 2000
50, 98, 220,
450
390, 880, 1560
50, 98, 220,
450
390, 880, 1560
39, 78, 220,
450
390, 880, 1560
50, 98, 220,
450
390, 880, 1560
ER412
Page 6
(800) 284-7007 • www.teledynerelays.com
♦
+44 (0) 1236 453124 • www.teledyne-europe.com
© 2008 Teledyne Relays
Established Reliability T²R Relays Selection Matrix
Series
SPDT - Latching
ER421
ER421D
ER421DD
ER420
ER420D
DPDT - Latching
ER420DD
ER422
ER422D
ER422DD
SPDT - Non-Latching
ER431
ER431D
ER431DD
ER431T
DPDT - Non-Latching
ER432
ER432D
ER432DD
ER432T
Nominal
Voltage
(Vdc)
5, 6, 9,
12, 18, 26.5
5, 6, 9,
12, 18, 26.5
5, 6, 9,
12, 18, 26.5
5, 6, 9,
12, 18, 26.5
5, 6, 9,
12, 18, 26.5
5, 6, 9,
12, 18, 26.5
5, 6, 9,
12, 18, 26.5
5, 6, 9,
12, 18, 26.5
5, 6, 9,
12, 18, 26.5
5, 6, 9, 12,
18, 26.5
5, 6, 9, 12,
18, 26.5
5, 6, 9, 12,
18, 26.5
5, 6, 9, 12,
18, 26.5
5, 6, 9, 12,
18, 26.5
5, 6, 9, 12,
18, 26.5
5, 6, 9, 12,
18, 26.5
5, 6, 9, 12,
18, 26.5
DPDT = Double-Pole, Double-Throw
SPDT = Single-Pole, Double-Throw
© 2008 Teledyne Relays
Nominal Coil
Typical
Resistance
Operating
(Ω)
Power (mW)
61, 120, 280,
290
500, 1130, 2000
61, 120, 280,
290
500, 1130, 2000
48, 97, 280,
290
500, 1130, 2000
61, 120, 280,
290
500, 1130, 2000
61, 120, 280,
290
500, 1130, 2000
48, 97, 280,
290
500, 1130, 2000
61, 120, 280,
290
500, 1130, 2000
61, 120, 280,
290
500, 1130, 2000
48, 97, 280,
290
500, 1130, 2000
125, 255, 630,
150
1025, 2300, 4000
125, 255, 630,
150
1025, 2300, 4000
100, 200, 630,
150
1025, 2300, 4000
125, 255, 630,
150
1025, 2300, 4000
100, 200, 400,
200
850, 1600, 3300
100, 200, 400,
200
850, 1600, 3300
64, 125, 400,
200
850, 1600, 3300
100, 200, 400,
200
850, 1600, 3300
ER420
ER422
ER431D
ER = Teledyne Relays Established Reliability T²R Program
see Appendix B for more details.
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE
Page 7
Military Qualified (JAN) Relays Selection Matrix
QPL
Number
Series
J114
J114
M39016/17
J114D
M39016/18
DPDT - Non-Latching
J114DD M39016/19
J116C
M28776/6
J134
M39016/41
J134D
M39016/42
J134DD M39016/43
J134
SPDT - Non-Latching
J136C
M28776/7
J411
M39016/7
J411D
M39016/23
J411DD M39016/24
J411T
M28776/5
J412
M39016/9
J412D
M39016/15
J412D
DPDT - Non-Latching
J412DD M39016/20
J412T
M28776/1
J255
M39016/45
Nominal
Voltage
(Vdc)
5, 6, 9,
12, 18, 26.5
5, 6, 9,
12, 18, 26.5
5, 6, 9,
12, 18, 26.5
5, 6, 9,
12, 18, 26.5
5, 6, 9,
12, 18, 26.5
5, 6, 9,
12, 18, 26.5
5, 6, 9,
12, 18, 26.5
5, 6, 9,
12, 18, 26.5
5, 6, 9,
12, 18, 26.5
5, 6, 9,
12, 18, 26.5
5, 6, 9,
12, 18, 26.5
5, 6, 9,
12, 18, 26.5
5, 6, 9,
12, 18, 26.5
5, 6, 9,
12, 18, 26.5
5, 6, 9,
12, 18, 26.5
5, 6, 9,
12, 18, 26.5
Nominal Coil
Typical
Resistance
Operating
(Ω)
Power (mW)
50, 98, 220,
450
390, 880, 1560
50, 98, 220,
450
390, 880, 1560
39, 78, 220,
450
390, 880, 1560
39, 78, 220,
450
390, 880, 1560
100, 200, 400,
200
800, 1600, 3200
100, 200, 400,
200
800, 1600, 3200
64, 125, 400,
200
800, 1600, 3200
100, 200, 400
200
800, 1600, 3200
63, 125, 280,
300
500, 1130, 2000
63, 125, 280,
300
500, 1130, 2000
50, 98, 280,
300
500, 1130, 2000
63, 125, 280,
300
500, 1130, 2000
50, 98, 220,
450
390, 880, 1560
50, 98, 220,
450
390, 880, 1560
39, 78, 220,
450
390, 880, 1560
50, 98, 220,
450
390, 880, 1560
5, 6,
12, 26.5
45, 63,
254, 1000
550
J255
Page 8
(800) 284-7007 • www.teledynerelays.com
♦
+44 (0) 1236 453124 • www.teledyne-europe.com
© 2008 Teledyne Relays
Military Qualified (JAN) Relays Selection Matrix
SPDT - Latching
Series
QPL
Number
J421
M39016/8
J421D
M39016/27
J421DD M39016/28
J420
M39016/12
J420D
M39016/29
DPDT - Latching
J420DD M39016/30
J422
M39016/12
J422D
M39016/29
J422DD M39016/30
SPDT - Non-Latching
J431
M39016/10
J431D
M39016/25
J431DD M39016/26
DPDT - Non-Latching
J431T
M28776/4
J432
M39016/11
J432D
M39016/16
J432DD M39016/21
J432T
M28776/3
DPDT = Double-Pole, Double-Throw
SPDT = Single-Pole, Double-Throw
© 2008 Teledyne Relays
Nominal
Voltage
(Vdc)
5, 6, 9,
12, 18, 26.5
5, 6, 9,
12, 18, 26.5
5, 6, 9,
12, 18, 26.5
5, 6, 9,
12, 18, 26.5
5, 6, 9,
12, 18, 26.5
5, 6, 9,
12, 18, 26.5
5, 6, 9,
12, 18, 26.5
5, 6, 9,
12, 18, 26.5
5, 6, 9,
12, 18, 26.5
5, 6, 9,
12, 18, 26.5
5, 6, 9,
12, 18, 26.5
5, 6, 9,
12, 18, 26.5
5, 6, 9,
12, 18, 26.5
5, 6, 9,
12, 18, 26.5
5, 6, 9,
12, 18, 26.5
5, 6, 9,
12, 18, 26.5
5, 6, 9,
12, 18, 26.5
Nominal Coil
Typical
Resistance
Operating
(Ω)
Power (mW)
61, 120, 280,
290
500, 1130, 2000
61, 120, 280,
290
500, 1130, 2000
48, 97, 280,
290
500, 1130, 2000
61, 120, 280,
290
500, 1130, 2000
61, 120, 280,
290
500, 1130, 2000
48, 97, 280,
290
500, 1130, 2000
61, 120, 280,
290
500, 1130, 2000
61, 120, 280,
290
500, 1130, 2000
48, 97, 280,
290
500, 1130, 2000
125, 255, 630,
150
1025, 2300, 4000
125, 255, 630,
150
1025, 2300, 4000
100, 200, 630,
150
1025, 2300, 4000
125, 255, 630,
150
1025, 2300, 4000
100, 200, 400,
200
850, 1600, 3300
100, 200, 400,
200
850, 1600, 3300
64, 125, 400,
200
850, 1600, 3300
100, 200, 400,
200
850, 1600, 3300
J421
J422D
J431
JAN = Teledyne Relays Military Qualified Relays
see Appendix B for more details.
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE
Page 9
Commercial Relays Selection Matrix
Nominal
Voltage
(Vdc)
5, 6, 9,
S114
12, 18, 26.5
5, 6, 9,
S114D
12, 18, 26.5
5, 6, 9,
S114DD
12, 18, 26.5
5, 6, 9,
S134
12, 18, 26.5
5, 6, 9,
S134D
12, 18, 26.5
5, 6, 9,
S134DD
12, 18, 26.5
S172 5, 12, 26.5
S172D 5, 12, 26.5
Series
S172
Non-Latching
Latching
122C
DPDT
172
172D
172
Non-Latching
712
712D
712TN
Latching
Non-Latching
712
Page 10
722
722D
732
732D
732TN
(800) 284-7007 • www.teledynerelays.com
♦
Nominal Coil
Resistance
(Ω)
50, 98, 220,
390, 880, 1560
50, 98, 220,
390, 880, 1560
39, 78, 220,
390, 880, 1560
100, 200, 400,
800, 1600, 3200
100, 200, 400,
800, 1600, 3200
64, 125, 400,
800, 1600, 3200
64, 400, 1600
64, 400, 1600
5, 6, 9,
48, 120, 280
12, 18, 26.5 500, 1130, 2000
5, 12, 26.5
5, 12, 26.5
5, 6, 9,
12, 18, 26.5
5, 6, 9,
12, 18, 26.5
5, 6, 9,
12, 18, 26.5
5, 6, 9,
12, 18, 26.5
5, 6, 9,
12, 18, 26.5
5, 6, 9,
12, 18, 26.5
5, 6, 9,
12, 18, 26.5
5, 6, 9,
12, 18, 26.5
64, 400, 1600
64, 400, 1600
50, 98, 220,
390, 880, 1560
50, 98, 220,
390, 880, 1560
50, 98, 220,
390, 880, 1560
61, 120, 280,
500, 1130, 2000
61, 120, 280,
500, 1130, 2000
100, 200, 400,
850, 1600, 3300
100, 200, 400,
850, 1600, 3300
100, 200, 400,
850, 1600, 3300
+44 (0) 1236 453124 • www.teledyne-europe.com
Typical
Operating
Power (mW)
450
450
450
200
200
200
390
390
290
390
390
450
450
450
290
290
200
200
200
© 2008 Teledyne Relays
Special Environmental Relays Selection Matrix
Nominal
Voltage
(Vdc)
5, 6, 9,
12, 18, 26.5
Nominal Coil
Typical
Resistance
Operating
(Ω)
Power (mW)
50, 98, 220,
450
390, 880, 1560
432H
5, 6, 9,
12, 18, 26.5
100, 200, 400,
850, 1600,
3300
422H
5, 6, 9,
12, 18, 26.5
422K
5, 6, 9,
12, 18, 26.5
Series
High Temperature
Non-Latching
412H
Latching
High Shock
DPDT
Non-Latching
High Vibration
5, 6, 9,
12, 18, 26.5
5, 6, 9,
412V
12, 18, 26.5
5, 6, 9,
412DV
12, 18, 26.5
5, 6, 9,
412DDV
12, 18, 26.5
5, 6, 9,
432V
12, 18, 26.5
5, 6, 9,
432DV
12, 18, 26.5
412K
DPDT = Double-Pole, Double-Throw
SPDT = Single-Pole, Double-Throw
61, 120, 280,
500, 1130,
2000
61, 120, 280,
500, 1130,
2000
50, 80, 160,
300, 600, 1350
50, 70, 155,
235, 610, 1130
33, 44, 125,
215, 470, 1050
33, 44, 125,
215, 470, 1050
80, 120, 240,
480, 950, 1900
80, 120, 240,
480, 950, 1900
200
412H
290
290
500
620
620
620
422H
350
350
JAN = Teledyne Relays Military Qualified Relays
see Appendix B for more details.
432DV
© 2008 Teledyne Relays
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE
Page 11
Teledyne Relays Part Numbering System
RF Attenuator Relays
A150
-
20
-
26
/
S
Q
Relay Series
Q = Solder-Coated Leads
G = Gold-Plated Leads (RoHS Compliant)
* Parts ordered without Suffix may be received with
Solder-Coated or Gold-Plated leads.
Attenuation Value (dB)
S = 0.187” Leads
No Suffix = 0.75” Leads
Nominal Coil Voltage
(26 = 26.5 V)
RF Relays
RF100
X
-
26
/
S
Q
Relay Series
Q = Solder-Coated Leads
G = Gold-Plated Leads (RoHS Compliant)
Ground Pin Option
(See Appendix A)
* Parts ordered without Suffix may be received with
Solder-Coated or Gold-Plated leads.
* Not Applicable for GRF Relays
S = 0.187” Leads
No Suffix = 0.75” Leads
* Not Applicable for GRF Relays
Nominal Coil Voltage
(26 = 26.5 V)
T2R Established Reliability Relays
ER
114
Y
M4
-
26
A
/
S
Established Reliability Designator
Q
Q = Solder-Coated Leads
G = Gold-Plated Leads (RoHS Compliant)
Relay Series
* Parts ordered without Suffix may be received with
Solder-Coated or Gold-Plated leads.
Ground Pin Option
(See Appendix A)
Pad Option
(See Appendix A)
Nominal Coil Voltage
(26 = 26.5 V)
S = 0.187” Leads
W = 1.5” Leads
No Suffix = 0.75” Leads
Screening and Reliability Level
(See Appendix for Screening Options B)
Military Qualified (JAN) Relays
J
114
Z
Military (JAN) Designator
26
P
L
P = 0.187” Leads
W = 1.5” Leads
No Suffix = 0.75” Leads
Ground Pin Option
(See Appendix A)
Pad Option
(See Appendix A)
(800) 284-7007 • www.teledynerelays.com
-
Screening and Reliability Level
(See Appendix for Screening Options B)
Relay Series
Page 12
M4
Nominal Coil Voltage
(26 = 26.5 V)
♦
+44 (0) 1236 453124 • www.teledyne-europe.com
© 2008 Teledyne Relays
Teledyne Relays Part Numbering System
Commercial Surface Mount Relays
S114D
-
26
/
G
Q = Solder-Coated Leads
G = Gold-Plated Leads (RoHS Compliant)
Relay Series
* Surface Mount Relays are Solder-Coated by default
Nominal Coil Voltage
(26 = 26.5 V)
Commercial Relays
172
X
M4
-
26
/
S
Q
Q = Solder-Coated Leads
G = Gold-Plated Leads (RoHS Compliant)
Relay Series
* Parts ordered without Suffix may be received with
Solder-Coated or Gold-Plated leads.
Ground Pin Option
(See Appendix A)
Pad Option
(See Appendix A)
S = 0.187” Leads
No Suffix = 0.75” Leads
Nominal Coil Voltage
(26 = 26.5 V)
Special Environmental / HI-REL Relays
412DV
Relay Series
Ground Pin Option
(See Appendix A)
Pad Option
(See Appendix A)
X
M
-
26
/
S
G
Q = Solder-Coated Leads
G = Gold-Plated Leads (RoHS Compliant)
* Parts ordered without Suffix may be received with
Solder-Coated or Gold-Plated leads.
S = 0.187” Leads
W = 1.5” Leads
No Suffix = 0.75” Leads
Nominal Coil Voltage
(26 = 26.5 V)
If you don’t see what you’re looking for
in this Selection Guide, contact us!
© 2008 Teledyne Relays
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE
Page 13
CERTIFICATE OF COMPLIANCE
It is Hereby Stated and Certified
That the Company (TELEDYNE RELAYS) complies with the
Restrictions on Hazardous Substances (RoHS) Directives
to the extent stated herein:
Teledyne Relays does not use any of the Restricted Substances specified by
the RoHS Directives (listed below) as components in TO-5 and Centigrid®
Electromechanical Relay products, nor are these substances employed during
any electromechanical relay manufacturing process:
Lead
Mercury
Cadmium
Hexavalent Chromium
Polybrominated Biphenyls (PBB’s)
Polybrominated Diphenyl Ethers (PBDE’s)
However, upon request from the Customer, relay leads may be coated with
solder, which contains 60% tin and 40% lead.
www.teledynerelays.com
(800) 284-7007 relays@teledyne.com
Page 14
(800) 284-7007 • www.teledynerelays.com
♦
+44 (0) 1236 453124 • www.teledyne-europe.com
© 2008 Teledyne Relays
Appendix A: Spacer Pads
Pad designation and
bottom view dimensions
Ø.150
Ø.150
[3.81]
[3.81]
(REF)
(REF)
Ø.150
[3.81] Ø.150
(REF) [3.81]
(REF)
Ø.150
Ø.150 [3.81]
[3.81] Ø.150
(REF)
(REF)
Ø.150 [3.81]
[3.81] (REF)
(REF)
“M4” Pad for TO-5
Height
Dim H
Dim H
MAX
MAX
Dim H
MAX Dim H
MAX
Dim H
Dim H MAX
MAX Dim H
Dim H MAX
MAX
Dim H
Dim H
MAX
MAX
Dim H
MAX Dim H
MAX
Dim H
Dim H MAX
MAX Dim H
Dim H MAX
MAX
“M4” Pad for TO-5
Dim H
Dim H
MAX
MAX
Dim H
MAX Dim H
MAX
.156
[3.96]
(REF)
.156
[3.96]
(REF)
.156
[3.96]
(REF)
.256
[6.5]
(REF)
.156
[3.96]
(REF)
.156
.156
[3.96]
[3.96] (REF)
.156
(REF)
.156
[3.96]
[3.96] (REF)
(REF)
.256 Pad for Centigrid®
“M4”
[6.5]
.256
[6.5]
(REF)
.256
[6.5]
(REF)
.256
[6.5]
(REF)
(REF)
.256
[6.5]
(REF)
.256
[6.5]
(REF)
.256
[6.5]
(REF)
“M9” Pad for Centigrid®
Dim H
Dim H MAX
MAX Dim H
Dim H MAX
MAX
Dim H
Dim H
MAX
MAX
For use with the following:
ER411T
ER412, ER412D, ER412DD
712, 712D, 712TN,
RF300, RF310, RF320
ER420, ER422D, ER420DD, 421,
ER421D, ER421DD, ER422, ER422D,
ER422DD, 722, 722D, RF341
ER431T, ER432T,
ER432, ER432D, ER432DD
732, 732D, 732TN, RF303, RF313,
RF323
Dim. H
Max.
.295 (7.49)
.300 (7.62)
.305 (7.75)
.400 (10.16)
.410 (10.41)
RF312
.350 (8.89)
ER411, ER411D, ER411DD
.295 (7.49)
ER431, ER431D, ER431DD
.400 (10.16)
RF311
.300 (7.62)
RF331
.410 (10.41)
172, 172D
.305 (7.75)
ER114, ER114D, ER114DD,
J114, J114D, J114DD
.300 (7.62)
ER134, ER134D, ER134DD,
J134, J134D, J134DD
.400 (10.16)
RF100
.315 (8.00)
RF103
.420 (10.67)
Dim H
MAX Dim H
MAX
122C, A152
.320 (8.13)
Dim H
Dim H MAX
MAX Dim H
Dim H MAX
MAX
ER116C, J116C
.300 (7.62)
ER136C, J136C
.400 (10.16)
RF180
.325 (8.25)
A150
.305 (7.75)
Notes:
1. Spacer pad material: Polyester film.
2. To specify an “M4” or “M9” spacer pad, refer to the mounting variants portion of the part numbering
example in the applicable datasheet.
3. Dimensions are in inches (mm).
4. Unless otherwise specified, tolerance is ± .010 (.25).
5. Add 10 mΩ to the contact resistance shown in the datasheet.
6. Add 0.01 oz. (0.25 g) to the weight of the relay assembly shown in the datasheet.
© 2008 Teledyne Relays
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE
Page 15
Appendix A: Spreader Pads
Pad designation and
bottom view dimensions
.370[9.4]
[9.4]
.370
MAX SQ
SQ
MAX
.370[9.4]
[9.4]
.370
MAX SQ
SQ
MAX
.370
.370[9.4]
[9.4]
MAX
MAX SQ
SQ
.150
.150
[3.81]
[3.81]
.150
.150
[3.81]
[3.81]
.300
.300
[7.62]
[7.62]
.300
.300
[7.62] .150
[7.62]
.150
[3.81]
[3.81]
.300
.300
[7.62]
[7.62]
.100
.100
[2.54]
[2.54]
.100
.100
[2.54]
[2.54]
.100
.100
[2.54]
[2.54]
.100
.100
[2.54]
[2.54]
.100
.100
[2.54]
[2.54]
.200
.200
[5.08]
[5.08]
.200
.200
[5.08]
[5.08]
.200
.200
[5.08]
[5.08]
.390
[9.91]
.390
[9.91]
SQ
SQ
.390[9.91]
[9.91]
.390
SQ
SQ
.100
.100
[2.54]
[2.54]
"M" Pad 5/ 6/
.390
.390[9.91]
[9.91]
SQ
SQ
.100
.100
[2.54]
[2.54]
.100
.100
[2.54]
.300 [2.54]
.300
[7.62]
[7.62]
.300 .100
.300
.100
[7.62] [2.54]
[7.62]
[2.54]
.300
.300
[7.62]
[7.62]
.300
.300
[7.62]
[7.62]
.300
.3007/ 8/
"M2" Pad
[7.62]
[7.62]
.370[9.4]
[9.4]
.370
MAX SQ
SQ
MAX
.370[9.4]
[9.4]
.370
MAX SQ
SQ
MAX
.370
.370[9.4]
[9.4]
MAX
MAX SQ
SQ
.150
.150
[3.81]
[3.81]
.150
.150
[3.81]
[3.81]
.300
.300
[7.62]
[7.62]
.300
.300
[7.62] .150
[7.62]
.150
[3.81]
[3.81]
.300
.300
[7.62]
[7.62]
.100
.100
.150
.150
[2.54]
[2.54]
[3.81]
[3.81]
.150
.150
[3.81]
[3.81]
.150
.150
[3.81]
[3.81]
.150
.150
[3.81]
[3.81]
.150
.150
[3.81]
[3.81]
.100
.100
[2.54]
[2.54]
.100
.100
[2.54]
[2.54]
.100
.100
[2.54]
[2.54]
.100
.100
[2.54]
[2.54]
.100
.100
[2.54]
[2.54]
.200
.200
[5.08]
[5.08]
.200
.200
[5.08]
[5.08]
.200
.200
[5.08]
[5.08]
Dim HH
Dim
MAX
MAX
Dim
Dim
HH
MAX
MAX
For use with the following:
.014
.014
[0.36]
[0.36]
.014
.014
(REF)
(REF)
[0.36]
[0.36]
(REF)
(REF)
.014
.014
[0.36]
[0.36]
(REF)
(REF)
Dim
Dim HH
MAX
MAX
.370
.370
[9.4]
[9.4]
.370
.370
MIN
MIN
[9.4]
[9.4]
MIN
MIN
.370
.370
[9.4]
[9.4]
MIN
MIN
.100
.100
[2.54]
[2.54]
.100
.100
[2.54]
[2.54]
.150
.150
[3.81]
[3.81]
.300
.300
[7.62]
[7.62]
Height
.100
.100
[2.54]
[2.54]
Dim HH
Dim
MAX
MAX
Dim
Dim
HH
MAX
MAX
ER411T, J411T, ER412, ER412D
ER412DD, J412, J412D, J412DD
ER412T, J412T
712, 712D, 712TN
ER431T, J431T, ER432, ER432D
ER432DD, J432, J432D, J432DD
ER432T, J432T
732, 732D, 732TN
.130
.130
[3.3]
[3.3]
.130
.130
[3.3]
[3.3]
.130
.130
[3.3]
[3.3]
H
MAX
MAX
.014
.014
[0.36]
[0.36]
.014
.014
(REF)
(REF)
[0.36]
[0.36]
(REF)
(REF)
.014
.014
[0.36]
[0.36]
(REF)
(REF)
Dim
Dim HH
MAX
MAX
.370
.370
[9.4]
[9.4]
.370
.370
MIN
MIN
[9.4]
[9.4]
MIN
MIN
.370
.370
[9.4]
[9.4]
MIN
MIN
"M3" Pad 5/ 6/ 9/
.393 (9.99)
.493 (12.52)
.503 (12.78)
.398 (10.11)
ER411T
ER412, ER412D, ER412DD
J412, J412D, J412DD
.441 (11.20)
732, 732D
Dim HH
Dim
MAXH
MAX
Dim
Dim
.388 (9.86)
ER420, J420, ER420D, J420D
ER420DD, J420DD, ER421, J421
ER421D, J421D, ER421DD
J422D, ER422DD, J422DD, 722
712, 712D
ER421, ER421D, ER421DD
722, 732D
ER431T
ER432, ER432D, ER432DD
Dim
Dim HH
MAX
MAX
Dim. H
Max.
ER411, ER411D, ER411DD
ER411TX
ER412X, ER412DX, ER412DDX
ER412TX
712X, 712DX, 712TNX
ER420X, ER420DX, ER420DDX
ER421X, ER421DX, ER421DDX
ER422X, ER422DX
ER422DDX, 722X, 722DDX
ER431, ER431D, ER431DD
ER431TX
ER432X, ER432DX, ER432DDX
ER432TX
732X, 732DX, 732TNX
.451 (11.46)
.451 (11.46)
.546 (13.87)
.556 (14.12)
.388 (9.86)
.393 (9.99)
.398 (10.11)
.493 (12.52)
.503 (12.78)
Notes:
1. Spreader pad material: Diallyl Phthalate.
2. To specify an “M”, “M2” or “M3” spreader pad, refer to the mounting variants portion of the part number example
in the applicable datasheet.
3. Dimensions are in inches (mm).
4. Unless otherwise specified, tolerance is ± .010” (0.25).
5/. Add 25 mΩ to the contact resistance shown in the datasheet.
6/. Add .01 oz. (0.25 g) to the weight of the relay assembly shown in the datasheet.
7/. Add 50 mΩ to the contact resistance shown in the datasheet.
8/. Add 0.025 oz (0.71 g) to the weight of the relay assembly shown in the datasheet.
9/. M3 pad to be used only when the relay has a center pin (e.g. ER411M3-12A, 722XM3-26.)
Page 16
(800) 284-7007 • www.teledynerelays.com
♦
+44 (0) 1236 453124 • www.teledyne-europe.com
© 2008 Teledyne Relays
.050
[1.27]
.050
[1.27]
"X"
POSITION
"X" POSITION
Appendix A: Ground
Pin Positions
"U" POSITION
"U" POSITION
.100
[2.54]
Ø.200
[Ø5.08]
Ø.200
[Ø5.08]
.100
[2.54]
.100
[2.54]
36°±3°
.100
[2.54]
(ER116C and
ER136C
(ER116C
andonly)
ER136C only)
"Z"
POSITION
"Z" POSITION
"X"
POSITION
"X" POSITION
"Y" POSITION
"Y" POSITION
"Y" POSITION
36°±3°
"Z"
POSITION
"Z" POSITION
Ø.200
[Ø5.08]
LEGEND:
45°±3°
"Y"
45°±3°
Ø.200
[Ø5.08]
POSITION
"Y" POSITION
Glass Insulated Lead
position
"Z" POSITION
TO-5 Relays:
ER411T, ER412, ER412T, ER420, ER421, ER422,
ER431T, ER432, ER432T, 712, 712TN, 400H, 400K,
400V, RF300, RF303, RF341, RF312, RF310, RF313,
RF320, RF323
TO-5 Relays:
Ground
PinER431,
position
ER411,
RF311, RF331
Either Ground Pin or
Insulated Lead position
depending on Relay type
.100
[2.54]
"Y"
.100
[2.54]
"W"
"Z"
.100
[2.54]
.050
[1.27]
"X"
[Ø5.08]
ON
ITION
ON
ON
POSITION
"X"
POSITION
(ER116C and ER136C only)
[2.54]
Insulated Lead position
lead position
Indicates ground pin or lead position
Either
Ground
PinPOSITION
or type
depending
on"Y"
Relay
Ground
Pin position
depending
on position
relay type
Insulated
Lead
depending
on
Relay
Either Ground Pin or type
Insulated Lead position
on Relay type
© 2008 Teledynedepending
Relays
POSITION
"Y"
POSITION
"W"
POSITION
Ø.200
[Ø5.08]
position
Glass Insulated Lead
LEGEND:
position
Indicates
Ground
Pinground
positionpin position
36°±3°
"Z"
.100
[2.54]
Centigrid® Relays:
RF100, RF103, ER114, ER134, 172
.100"Z" POSITION
POSITION
Glass
Insulated
Lead
Ground
Pinglass
position
Indicates
insulated
Either
Ground
Pin
or
position
POSITION
.100
[2.54]
POSITION
LEGEND:
Glass Insulated Lead
ITION
"Y"
POSITION
Centigrid® Relays:
RF180, ER116C, 122C, ER136C
"Z" POSITION
LEGEND:
.100
[2.54]
"U"
.100
[2.54]
ON
Ø.200
POSITION
45°±3°
"Z" POSITION
NOTES.100
[2.54]
1. Terminal views shown
2. Dimensions
are in inches (mm)
.050
[1.27]
"X" POSITION
3. Tolerances:
± .010 (±.25) unless otherwise specified
4. Ground pin positions are within .015 (0.38) dia. of true position
"Y" dia.,
POSITION
5. Ground pin head
0.035 (0.89) ref: height 0.010 (0.25) ref.
"U" POSITION
6. Lead dia. 0.017 (0.43) nom. .100
[2.54]
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE
(ER116C and ER136C only
Page 17
Appendix B: Teledyne Relays T2R Program
Teledyne Relays’
program was developed to provide the JAN relay user an alternate means of specifying and procuring
relay is the same as that of its JAN counterpart.
program
established reliability relays. The form, fit and function of a
requirements differ in certain regimens/tests found in both MIL-PRF-28776 and MIL-PRF-39016 that add cost but no value to
the relay.
This program parallels the military specifications in most aspects. The components that make up such a program are intricate
and varied. It is very difficult to detail on a one-to-one basis how the two programs differ. The following page presents a table
that compares the 100% screening performed on JAN relays and
relays prior to shipment.
Other significant highlights of the
program include:
• Two unique screening levels
• The ability to define lead finish
• Spacer pad options not allowed by the military specifications
• Ground pin options not allowed by the military specifications
• Reduced lead time
• Reduced cost
The program is fully defined for both general product requirements and detailed product requirements in the following Teledyne
Relays specifications:
TR-R-1
TR-STD-1
TR-STD-2
TR-ERL-1
TR-R-1/XXX
TR Supplement
Copies of these documents are available from Teledyne Relays. We suggest that users check with Teledyne Relays from time
to time to assure that they have the latest issue.
Can’t Find What You Need?
Check out our full line of relays and switches. Order literature online at
http://www.teledynerelays.com/litrequest.asp
Page 18
(800) 284-7007 • www.teledynerelays.com
♦
+44 (0) 1236 453124 • www.teledyne-europe.com
© 2008 Teledyne Relays
Appendix B: Teledyne Relays T2R Program
Screening Levels
Applicable To
INSPECTION
A Level
1.5%/10K Cycles
B Level
.75%/10K Cycles
JAN L Level
3%/10K Cycles
JAN M Level
1%/10K Cycles
X
X
X
X
Subgroup 1
Screening, Internal Moisture AQL
Vibration (Sinusoidal) AQL
X
Vibration (Sinusoidal) 100%
X
Screening, Burn-In (Hybrids only)
X
X
X
X
X
X
Screening, Run-In (Room Temperature)
X
X
Screening, Run-In (+125°C and –65°C)
Subgroup 2
Coil Resistance or Coil Current
X
X
X
X
Insulation Resistance
X
X
X
X
Dielectric Withstanding Voltage
X
X
X
X
Static Contact Resistance
X
X
X
X
Pickup and Dropout or Set and Reset Voltage
X
X
X
X
Operate and Release or Set and Reset Time
X
X
X
X
X
X
X
X
Hold Voltage
Turn-On and Turn-Off Time (Hybrids only)
X
Contact Bounce Time
X
Contact Stabilization Time
X
X
X
X
Turn-On Current (T Hybrids only)
X
X
X
X
Turn-On voltage (C Hybrids only)
X
X
X
X
Turn-Off Voltage (Hybrids only)
X
X
X
X
Coil Transient Suppression
(D, DD and Hybrids only)
X
X
X
X
Diode Blocking Integrity (DD only)
X
X
X
X
Zener Voltage (C Hybrid only)
X
X
X
X
Neutral Screen (Latching Relays only)
X
X
X
X
Break Before Make Verification
X
X
Contact Simultaneity
X
X
Subgroup 3
Solderability 2 Samples per Daily Solderability
Inspection Lot
X
X
X
X
Leak Test
X
X
X
X
External Visual and Mechanical Inspection 2/Lot for
Dimension and Weight Check
X
X
X
X
© 2008 Teledyne Relays
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE
Page 19
Appendix: Teledyne Relays HI-REL Program
Teledyne Relays: Because in deep space
there is no acceptable failure rate
Teledyne Relays has a long history of supplying High
Reliability relays for use in space bound vehicles. From the
earliest deep space probes, such as Voyager I, now nearing
10 billion miles out in space, to the next generation of probes
scheduled for the future , Teledyne Relays continues to be
the preeminent supplier of Hi-Reliability relays to the space
market.
Relay Types
TO-5 Magnetic-Latching Relays
TO-5 Non-Latching Relays
TO-5 Magnetic-Latching, High-Shock Relays
TO-5 Non-Latching, High-Shock Relays
TO-5 Non-Latching, High-Vibration Relays
Hi-Rel Screening Capabilities
100% Open Electrical Inspection
100% Precap Inspection
Fully Automated Small Particle Inspection
(Millipore Clean)
Asynchronous Miss Test
Coil Continuity
Sine Vibration
Random Vibration
High/Low Run In
(Miss Test) –65 ºC ± 125 ºC
Radiographic Inspection
Mechanical Shock Test
Thermal Shock Test
Teledyne Screening Document 0-40-837
NASA approved screening regimen based on NASA/GSFC Acceleration
Radiographic Inspection (X-ray)
S-311-P.754
Mechanical Shock Test
Thermal Shock Test
Acceleration
Load Banks for a Variety of Life Test Load
Serialized Printed Electrical Data
Continuous Life Testing
Environmental Testing
Vertical Integration
Teledyne Relays Hi-Reliability Specification:
TR-HIREL-1
• Eliminates the need for customers to develop and maintain
specifications.
• Manufacturing and Quality Assurance requirements are
fully defined and documented.
• Meets the general requirements of both ESA/SCC and
NASA/GSFC documents.
• Offers options for 100% Group A screening
• Offers options for 3 levels of Lot Acceptance Testing
(LAT).
For information or answers to your questions, contact
Dan Yracheta, Program Manager, at (323) 241-1218 or
dyracheta@teledyne.com.
Page 20
(800) 284-7007 • www.teledynerelays.com
♦
+44 (0) 1236 453124 • www.teledyne-europe.com
© 2008 Teledyne Relays
Authorized Distributors
NORTH AMERICA
ALLIED ELECTRONICS
Tel: (800) 433-5700
www.alliedelec.com/search.asp
FINLAND
ARROW Finland Oy
Tel: +358 9 4766 6396
www.arrowne.com
ASAP ELECTRONICS
Tel: (800) 477-1272
www.asapelectronics.com
FRANCE
ARROW France
Tel: +33 1 4180 8424
E-mail: ralves@arrowfrance.com
AVNET
Tel: (800) 772-8638
www.em.avnet.com
CCA-WESCO
(Solid State Relays Only)
Tel: (508) 870-5000
www.cca-corp.com
MASTER DISTRIBUTORS
Tel: (888) 473-5297
www.onlinecomponents.com
MOUSER ELECTRONICS
Tel: (800) 346-6873
www.mouser.com
RICHARDSON ELECTRONICS
Tel: (800) 737-6937
www.rell.com
SHERBURN ELECTRONICS
Tel: (800) 366-3066
www.sherburn.com
INTERNATIONAL
RICHARDSON ELECTRONICS
Tel: (800) 737-6937
www.rell.com
BELGIUM & LUXEMBOURG
Nijkerk Electronics nv
Tel: +32 (0) 3 544 7066
E-mail: peter.vanhal@nijkerk.be
www.nijkerk-ne.com
CANADA
Cee-Jay Microsystems
Tel: (613) 599-5626
www.cjmicro.com
CHINA & HONG KONG
El-Pax, Inc.
USA Head Office
Tel: 650-692-8896
E-mail: elpax@fiaco.com
Beijing Office
Tel: 86-10-6503-2171
E-mail: beijing@fiaco.com
CZECH REPUBLIC
Amtek spol. s.r.o.
Tel: +420 547 125 555
E-mail: amtek@amtek.cz
www.amtek.cz
DENMARK
ARROW Denmark A/S
Tel: +45 (0) 70102211
E-mail: jbh@arrownordic.com
www.arrowne.com
ESTONIA
ARROW Estonia
Tel: +372 6 774250
E-mail: estonia@arrownordic.com
www.arrowne.com
© 2008 Teledyne Relays
GERMANY
Adelco Elektronik GmbH
Tel: +49 (0) 4106 61040
E-mail: adelco@t-online.de
www.adelco-elektronik.de
Hot Electronic GmbH
Tel:+49 (0) 89 666 2836
E-mail: info@hot-electronic.de
www.hot-electronic.de
MRC Components oHG
Tel: +49 (0) 8161 98480
E-mail: info@mrccomponents.de
www.mrccomponents.de
Zettler electronics GmbH
Tel: +49 (0) 89 800 97-0
E-mail: office@zettlerelectronics.com
www.zettlerelectronics.com
INDIA
Specsynergy Technologies, Inc.
San Jose, CA (Main Office)
Tel: (408) 954-8474 x105
E-mail: karthik@spectraus.com
Specsynergy Technologies, Inc.
New Delhi Office
Tel: 91 11 25860 752
E-mail: malik@specsynergytech.com
ISRAEL
STG International Ltd.
Tel: +972 (0) 3 733 1400
E-mail: davidb@stggroup.co.il
www.stggroup.co.il
ITALY
SINCRON s.r.l.
Tel: +39 02 95384218
E-mail: ermanno.baschieri@sincron.it
www.sincron.it
JAPAN
Comcraft Corporation Tokyo
Tel: 81-3-3395-5553
E-mail: trcsales@comcraft.co.jp
www.comcraft.co.jp
Comcraft Corporation Osaka
Tel: 81-6-6396-7722
E-mail: trcsales@comcraft.co.jp
www.comcraft.co.jp
KOREA
Electro-Comm USA
Tel: (323) 254-7790
E-mail: briansong@anyeparts.com
www.anyeparts.com
Electro-Comm SEOUL
Tel: 82-31-713-4216
E-mail: tony_jang@anyeparts.com
www.anyeparts.com
LATVIA
ARROW Latvia
Tel: +371 7311490
E-mail: latvia@arrownordic.com  
http:www.arrowne.com   LITHUANIA
ARROW Lithuania
Tel: +370-37-759015
E-mail: lithuania@arrownordic.com  
http:www.arrowne.com     MALAYSIA
Device Electronics PTE, Ltd.
Tel: (603) 7880 8626/8636
E-mail: ngthomas@devicelect.com
NETHERLANDS
Nijkerk Electronics B.V.
Tel: +32 (0) 3 544 7066
E-mail: peter.vanhal@nijkerk.be
www.nijkerk-ne.com
NORWAY
ARROW Norway A/S
Tel: +47 (0) 21306532
stondevoldshagen@arrownordic.com
www.arrowne.com
POLAND
Zettler electronics Poland sp.z.o.o.
Tel: +48 (0) 68 4791438
E-mail: office@zettlerelectronics.pl
www.zettlerelectronics.pl
RUSSIA
Petersburg Electronic Company JSC
Tel: +7 812 4488 777
e-mail: dkizha@pec.spb.ru
www.pec.spb.ru
SINGAPORE
Device Electronics PTE, Ltd.
Tel: 65-288 6455
E-mail: ngthomas@devicelect.com
SWEDEN
OEM Electronics
Tel: +46 75 242 4562
E-mail: ulf.nygren@oemelectronics.se
www.oemelectronics.se
SWITZERLAND
ENA AG
Tel: +41 56 6342834
E-mail: rolf.hochstrasser@ena.ch
www.ena.ch
TAIWAN
Bright Toward Industrial Co., Ltd.
Tel: +886-2-822-76000
E-mail: philip@relays.com.tw
www.relays.com.tw
UNITED KINGDOM
Arrow Electronics UK Ltd.
Tel: +44 (0) 1279 626 777
www.arrowne.com
Willow Technologies Ltd.
Tel: +44 (0) 1342 835 234
E-mail: sales@willow.co.uk
www.willow.co.uk
2001 Electronic Components Ltd.
Tel: +44 (0) 1438 742 001
E-mail: sales@2001elec.co.uk
www.2001elec.co.uk
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE
Page 21
HEADQUARTERS
12525 Daphne Ave.
Hawthorne, CA 90250
Phone: (323) 777-0077 or (800) 284-7007
Fax: (323) 241-1287
E-mail: relays@teledyne.com
www.teledynerelays.com
EUROPE
9-13 Napier Road
Wardpark North
Cumbernauld G68 OEF
Scotland UK
Phone: +44 (0) 1236 453 124
Fax: +44 (0) 1236 780 651
E-mail: sales_europe@teledyne.com
www.teledyne-europe.com
PRINTED IN U.S.A.
TR0408
Download