ARCLITE T6/7AA Spec Sheet ® recessed T6 metal halide accent H I D 8-675 light Features Arclite T6/7AA is a 7” aperture adjustable accent light designed for use with 39-watt, 70-watt or 150-watt T6 metal halide lamps, and is equipped with an electronic ballast and a protective glass shield. The fixture provides 358° horizontal lamp rotation and 0°– 40° angular adjustment with lockable focus. Precise reflector design minimizes aperture brightness. The standard top reflector configuration produces a narrow flood distribution; optional configurations are available for very narrow spot, spot or flood distributions. Arclite T6/7AA is relamped from below after removal of the bottom reflector and the protective glass. Both the bottom reflector and the protective glass are spring-mounted and require no tools for removal or re-insertion. Reflectors are available in clear, natural aluminum in two finishes: EvenTone, our standard clear finish, partially diffuse, anti-iridescent and gently luminous in appearance; and EasyTone, diffuse and luminous. Reflectors are also available in pewter and black. Arclite T6/7AA includes a pair of mounting bars (¾” x 27” C channel). Specialty bars for wood joist and T-bar installations are also available. Requires ceiling opening of 7 7/8” (200mm) for Overlap or Flush Detail. Requires ceiling opening of 8 3/16” (208mm) for Trim Flush Detail. PRODUCT CODE For complete product code, list basic unit and select one item from each following box. Basic Unit (narrow flood distribution)............................ARCT6/7AA Wattage 39-watt ballast (no fixture spacing restrictions) ......................–39 70-watt ballast (no fixture spacing restrictions)........................–70 150-watt ballast (see fixture spacing restrictions below).............. –150 APPLICATIONS Fixture is suitable for accent and display lighting in stores, malls, auditoriums, airports and sports facilities – especially in lobbies, atria and other public areas. Fixture is listed for Damp Location and suitable for use in a fire rated ceiling. Fixture is prewired with electronic ballast and thermal protector and is approved for ten #12 wire 90°C branch circuit pullthrough wiring. The ballast and junction box are accessible through the aperture of the fixture. fixture spacing restrictions Fixtures for use with 150-watt lamps must be spaced at least 36” apart and 18” from walls, and must have ½” clearance above housing. MODIFICATIONS AVAILABLE Voltage 120 volt service ................120 Reflector Color and Detail Overlap Trim Flush* EvenTone Clear.................................... VOL......................... VTF EasyTone Clear................................... ECOL...................... ECTF Pewter................................................ POL......................... PTF Black.................................................. BOL......................... BTF Other reflector finishes available on special order. Overlap Flange continues reflector finish. White painted flanges and custom painted flanges are available on special order. Add WF (white flange) or CCF (custom color flange). *Trim Flush reflector trim requires the use of a plaster ring Accessory (see below). Reflectors detailed for metal or wood ceilings available on special order. options Specify by adding to the end of basic unit. Narrow spot distribution . ....................................................– NSP Spot distribution ................................................................... – SP Flood distribution . ...............................................................– FLD Emergency: DC bayonet base socket only ................................ – EMA Auxiliary: DC bayonet base socket prewired to restrike relay;100 watt max lamp on 120 v service; 50 watt max on 277 v service .......– AUX accessories Specify as a separate line item. Plaster ring allows use of 7 7/8” OD Trim Flush (-TF) reflector in sheetrock ceiling; 8 3/16” dia hole required.......TF RING/7 Contact factory with quantity for pricing; orders may require shop drawing approval. CHP-: 70-watt fixture suitable for Chicago Plenum; add CHP- as prefix to Product Code. CONC-: 70-watt fixture suitable for poured-in-place concrete; add CONC- as prefix to Product Code. EXP-: `European-style´ install-from-below fixture; add EXP- as prefix to Product Code. +2”CLG: fixture suitable for installation in 2” thick ceiling material; add +2”CLG to Product Code. +DOD: fixture suitable for high humidity environments; add +DOD to Product Code. +MAR: reflector suitable for marine environments; add +MAR to Product Code. +TR: fixture prepared for top re-lamping; add +TR to Product Code. 277 volt service................ 277 Decorative reflector rings are available on special order. Contact factory. 41-50 22ND STREET, L IC NY 11101 © Copyright, Edison Price Lighting 2015 tel 718.685.0700 fax 718.786.8530 www.epl.com Arclite is a registered trademark of Edison Price Lighting 10:15 ® arclite T6/7AA Luminaire................lamp holder aimed at 30° above vertical Lamp......................Philips CDM150/T6/830, rated 14,000 lumens BALLAST INFORMATION Voltage 120 277 Voltage 120 277 Input Watts 165 161 Power Factor (%) >90 >90 Line Current (A) 1.4 .6 Min. Starting Temp (°F) –20 –20 PHOTOMETRIC REPORT – narrow FLOOD (standard configuration) Luminaire Testing Laboratory Report No. 12518. Original test report furnished upon request. Total luminaire efficiency: 59.7% Horizontal Angle 0 5 15 25 35 45 55 65 75 90 LUMINANCE DATA (Candela/m2) 0 45 90 135 180 5767 6572 10783 15863 15498 8562 2627 186 3 0 5767 6271 7757 7091 4932 2253 542 11 0 0 5767 5533 4876 2690 971 249 5 8 0 0 5767 5051 3343 1943 273 9 0 0 0 0 5767 4948 3154 1886 88 0 0 0 0 0 Vertical Angle Average Average Average 0° Longitude 90° Longitude 180° Longitude 487645 184452 17725 467 0 45 55 65 75 85 128319 38056 1048 0 0 14182 351 762 0 0 To convert cd/m2 to footlamberts, multiply by 0.2919. PHOTOMETRIC REPORT – narrow spot (optional configuration) Luminaire Testing Laboratory Report No. 12520. Original test report furnished upon request. Total luminaire efficiency: 43.3% Horizontal Angle 0 5 15 25 35 45 55 65 75 90 LUMINANCE DATA (Candela/m2) 0 45 90 135 180 2965 3406 7411 40116 43932 5708 252 0 0 0 2965 3296 3895 2555 1419 173 0 0 0 0 2965 2760 1876 363 32 0 0 0 0 0 2965 2271 647 47 0 0 0 0 0 0 2965 2208 536 0 0 0 0 0 0 0 Vertical Angle 45 55 65 75 85 Average Average Average 0° Longitude 90° Longitude 180° Longitude 325170 17718 0 0 0 9881 0 0 0 0 0 0 0 0 0 To convert cd/m2 to footlamberts, multiply by 0.2919. PHOTOMETRIC REPORT – spot (optional configuration) Luminaire Testing Laboratory Report No. 12519. Original test report furnished upon request. Total luminaire efficiency: 53.5% Horizontal Angle 0 5 15 25 35 45 55 65 75 90 LUMINANCE DATA (Candela/m2) 0 45 90 135 180 4857 6560 11574 19522 18670 8515 2428 158 0 0 4857 5819 7506 6197 3643 1498 426 0 0 0 4857 4510 3359 1419 583 205 0 0 0 0 4857 3832 1656 1088 173 0 0 0 0 0 4857 3658 1325 1167 32 0 0 0 0 0 Vertical Angle 45 55 65 75 85 Average Average Average 0° Longitude 90° Longitude 180° Longitude 484968 170479 15056 0 0 85318 29911 0 0 0 11676 0 0 0 0 To convert cd/m2 to footlamberts, multiply by 0.2919. PHOTOMETRIC REPORT – FLOOD (optional configuration) Luminaire Testing Laboratory Report No. 12517. Original test report furnished upon request. Total luminaire efficiency: 59.6% Horizontal Angle 0 5 15 25 35 45 55 65 75 90 LUMINANCE DATA (Candela/m2) 0 45 90 135 180 6278 6629 9061 12180 11789 7544 2655 129 3 0 6278 6669 7824 7181 5305 2597 587 13 0 0 6278 6323 5940 3616 1273 266 11 9 0 0 6278 5946 4559 2422 273 13 9 6 0 0 6278 5872 4292 2223 82 16 0 0 0 0 Vertical Angle 45 55 65 75 85 Average Average Average 0° Longitude 90° Longitude 180° Longitude 429666 186418 12293 467 0 147911 41216 1239 0 0 15150 772 858 0 0 To convert cd/m2 to footlamberts, multiply by 0.2919.