AT&T 368-047 Parcel Map ENGINEER: SITE NAME PREPARED FOR: NUNN MTN at&t at&t SITE NUMBER 10017514 CONSULTANT: GENERATOR INSTALLATION Wireless Services NUNN MTN SITE NUMBER: 10017514 SHEET # ORANGE COUNTY ZONING: TBD SEAL: SHEET DESCRIPTION T1 TITLE SHEET A1 OVERALL SITE PLAN A2 ENLARGED SITE PLAN S1 FOUNDATION DETAILS E1 ELECTRICAL & GROUNDING DETAILS E2 ELECTRICAL & GROUNDING DETAILS SP1 GENERAL NOTES O 8/07/13 A.D.A. COMPLIANCE: FACILITY IS UNMANNED AND NOT FOR HUMAN HABITATION NAD83 LATTITUDE: LONGITUDE: GROUND ELEV: FA NUMBER: HASTY UTILTIES INC. 6801 US 64 HIGHWAY E. KNIGHTDALE, NC 27545 CONTACT: PHONE: TBD TBD SITE NUMBER: 368-082 APPLICANT: GENERAL DYNAMICS 1750 FOUNDERS PARKWAY SUITE 120 ALPHARETTA, GA 30009 SCALE: N.T.S. APPROVALS SCALE: N.T.S. SITE ADDRESS: 609 PINEY MOUNTAIN ROAD CHAPEL HILL, NC 27514 ORANGE COUNTY PROJECT MANAGER DATE CONSTRUCTION MANAGER DATE SITE ACQUISITION DATE OWNER DATE FROM RALEIGH, NC, HEAD WEST ON I-40. TAKE EXIT 266 FOR N CAROLINA 86 S AND TURN LEFT. TURN LEFT ONTO WEAVER DAIRY ROAD THEN TAKE THE 2ND RIGHT ONTO KINGSTON ROAD. TURN RIGHT ONTO PARTIN ST AND THEN RIGHT ONTO EMILY ROAD. EMILY ROAD TURNS SLIGHTLY LEFT AND BECOMES PINEY MOUNTAIN ROAD. SITE ON LEFT. CODE COMPLIANCE ALL WORK SHALL BE PERFORMED AND MATERIALS INSTALLED IN ACCORDANCE WITH THE CURRENT EDITIONS OF THE FOLLOWING CODES AS ADOPTED BY THE LOCAL GOVERNING AUTHORITIES. NOTHING IN THESE PLANS IS TO BE CONSTRUED TO PERMIT WORK NOT CONFORMING TO THESE CODES. 0 PROJECT MANAGER: NORM GILES (770) 225-1564 PHONE: 368-082 SITE NAME: DRIVING DIRECTIONS TOWER OWNER: SITE NUMBER: 10017514 609 PINEY MOUNTAIN ROAD CHAPEL HILL, NC 27514 TBD SS IO N SEAL 032960 OCCUPANCY TYPE: UNMANNED SITE ADDRESS: FE L WATER TANK JURISDICTION: LIST OF DRAWINGS LOCATION MAP A TOWER TYPE: VICINITY MAP 1. 2. 3. 4. 5. 6. 2006 INTERNATIONAL BUILDING CODE (NORTH CAROLINA STATE BUILDING CODE, 2009) 2006 INTERNATIONAL PLUMBING CODE (NORTH CAROLINA STATE PLUMBING CODE, 2009) 2006 INTERNATIONAL MECHANICAL CODE (NORTH CAROLINA STATE MECHANICAL CODE, 2009) 2011 NATIONAL ELECTRIC CODE (NORTH CAROLINA STATE ELECTRICAL CODE, 2008) 2002 NORTH CAROLINA STATE ACCESSIBILITY CODE 2006 INTERNATIONAL ENERGY CONSERVATION CODE (NORTH CAROLINA STATE ENERGY CODE, 2009) CONSULTANT TEAM ENGINEER/ARCHITECT: CONTACT: TELEPHONE: PROJECT MANAGER: DO NOT SCALE DRAWINGS HANDICAP REQUIREMENTS OTHER REQUIREMENTS FACILITY IS UNMANNED AND NOT FOR HUMAN HABITATION. HANDICAP ACCESS IS NOT REQUIRED. - FACILITY HAS NO PLUMBING OR PARKING. - NO GRADING WILL BE REQUIRED FOR THIS SITE. CONTRACTOR SHALL VERIFY ALL PLANS & EXISTING DIMENSIONS & CONDITIONS ON THE JOB SITE & SHALL IMMEDIATELY NOTIFY THE ARCHITECT IN WRITING OF ANY DISCREPANCIES BEFORE PROCEEDING WITH THE WORK OR BE RESPONSIBLE FOR SAME. CONTACT: TELEPHONE: SSOE, INC. 320 SEVEN SPRINGS WAY, SUITE 350 BRENTWOOD, TN 37027 FLOYD WHITE (615) 661-7585 GENERAL DYNAMICS 1750 FOUNDERS PARKWAY, SUITE 120 ALPHARETTA, GA 30009 NORM GILES (770) 225-1564 NO. 08/07/13 CONSTRUCTION DRAWINGS DATE SUBJECT 320 Seven Springs Way, Suite 350 Brentwood, TN 37027 T 615-661-7585 013-00178-00 Floyd White Greg Dulnik Travis Leute TITLE SHEET T1 C:\dgn\d0355681\10017514_A&E_ConstructionDrawings_20130510.dwg DATE: Aug 07, 2013 - 3:50pm USER: 14200 SITE NAME: PR PROJECT SUMMARY ENGINEER: at&t X X X X X X X PREPARED FOR: EXISTING LP TANK X X X PROPOSED AT&T 600G LP TANK X X EXISTING SHELTER X X X PROPOSED 10' NO SPARK SOURCE RADIUS X X EXISTING ICE BRIDGE X CONSULTANT: X X X X X X EXISTING SHELTER X Wireless Services X X X EXISTING WATER TANK TOWER EXISTING WATER TANK X X PROPOSED AT&T MOBILITY GENERATOR ON EXISTING CONCRETE PAD X SEAL: PR X X SS I O N X SEAL 032960 X X FE L EXISTING SHELTER O A X X X X X 8/07/13 X X X X FA NUMBER: SITE NUMBER: X X 10017514 368-082 X X SITE NAME: 609 PINEY MOUNTAIN ROAD CHAPEL HILL, NC 27514 ORANGE COUNTY X X X X SITE ADDRESS: X X X X X X X X X X X X X X X X 0 08/07/13 CONSTRUCTION DRAWINGS DATE SUBJECT X NO. X X X X 320 Seven Springs Way, Suite 350 Brentwood, TN 37027 T 615-661-7585 X X 013-00178-00 X X Floyd White Greg Dulnik Travis Leute X X X X X X X X X X X X X X X X X X X X X X X X X X 1 X X OVERALL SITE PLAN X OVERALL SITE PLAN SCALE: 1" = 30' NORTH A1 C:\dgn\d0355681\10017514_A&E_ConstructionDrawings_20130510.dwg DATE: Aug 07, 2013 - 3:50pm USER: 14200 X X X EXISTING GENERATOR EXISTING SHELTER X EXISTING EQUIPMENT PAD X X SEE DWG. E-1 FOR CONDUIT & WIRING SPECIFICATION/SINGLE LINE. EXISTING SHELTER X X 4. X CHANGE ORDERS WILL NOT BE ACCEPTED FOR UNAPPROVED WORK. X 3. X REFER TO DRAWINGS SP-1 FOR GENERAL NOTES. X 2. PROPOSED BOLLARDS (TYP.) X CONTRACTOR TO CALL 811 OR (800) 382-5544 OR OTHER LOCAL JOINT UTILITY LOCATOR SERVICE TO VERIFY THE LOCATION OF EXISTING UNDERGROUND UTILITIES PRIOR TO CONSTRUCTION. X 1. X EXISTING GENERATOR NOTES: ENGINEER: X NOTES: X X X 3. CHANGE ORDERS WILL NOT BE ACCEPTED FOR UNAPPROVED WORK. 4. SEE DWG. E-1 FOR CONDUIT & WIRING SPECIFICATION/SINGLE LINE. X PROPOSED AT&T 600G LP TANK PREPARED FOR: 13'-11" 4'-6" (TYP.) X REFER TO DRAWINGS SP-1 FOR GENERAL NOTES. PROPOSED BOLLARDS (TYP.) EXISTING GENERATOR at&t EXISTING SHELTER X X 2. X CONTRACTOR TO CALL 811 OR (800) 382-5544 OR OTHER LOCAL JOINT UTILITY LOCATOR SERVICE TO VERIFY THE LOCATION OF EXISTING UNDERGROUND UTILITIES PRIOR TO CONSTRUCTION. X 1. PROPOSED 10' NO SPARK SOURCE RADIUS 7'-6" (TYP.) X CONSULTANT: X X 3' (TYP.) 11'-6" X X Wireless Services X SEAL: X PROPOSED LP LINE X X 8'-3" 9' X X FE SS I O N SEAL 032960 EXISTING AT&T CABINETS AT&T METER RACK X O L PR X X X A X PROPOSED AT&T SUB-PANEL 7'-2" 8/07/13 EXISTING ICE BRIDGE M X X EXISTING ICE BRIDGE X FA NUMBER: SITE NUMBER: 10017514 368-082 X SITE NAME: X 23' SITE ADDRESS: 4'-10" 609 PINEY MOUNTAIN ROAD CHAPEL HILL, NC 27514 ORANGE COUNTY X X 3'-5" 10" EXISTING EQUIPMENT PAD PROPOSED AT&T MOBILITY GENERATOR ON EXISTING CONCRETE PAD X X X 8" POWER & COMMUNICATION CONDUITS (TYP. 4) TO EXIST. ATS INSIDE CABINET. SEE SHEET E-1 EXISTING WATER TANK TOWER EXISTING ASCO 300L SERIES ATS 5'-7" 3' 0 08/07/13 CONSTRUCTION DRAWINGS DATE SUBJECT X X NO. X X 320 Seven Springs Way, Suite 350 Brentwood, TN 37027 T 615-661-7585 013-00178-00 EXISTING GENERATOR Floyd White Greg Dulnik Travis Leute X X 10'-4" ENLARGED SITE PLAN 1 ENLARGED SITE PLAN SCALE: 1/8" = 1' NORTH A2 C:\dgn\d0355681\10017514_A&E_ConstructionDrawings_20130510.dwg DATE: Aug 07, 2013 - 3:51pm USER: 14200 4'-9" X X X X PROPOSED AT&T MOBILITY 5'-6"x11'-0" GENERATOR LEASE AREA X EXISTING SITE FENCE 3' ENGINEER: OUTLINE OF GENERATOR FOOTPRINT PREPARED FOR: at&t PROVIDE ADDITIONAL #4 U-BARS, TYPICAL AT EACH END OF STUB-UP AREA CONSULTANT: 4'-0" ELECTRICAL STUB-UP AREA REINFORCING BAR GRID; FOR SIZE AND SPACING, SEE SECTION 2 Wireless Services 60 FT-LB OF INSTALLATION TORQUE PR SS I O N SEAL 023408 4-1/8" 3-7/8" FE L 7-1/8"" O A 5-1/2" SEAL: 8/07/13 10'-0" FA NUMBER: STRONG BOLT 2 STAINLESS STEEL WEDGE ANCHORS, OR EQUAL, W/ 4-1/2" EMBEDMENT. COORDINATE LOCATION W/ EQUIPMENT DRAWINGS. PLAN FOR 10'-0"X4'-0" GENERATOR PAD SCALE: (5) #4 CHAMFER (TYP.) OUTLINE OF GENERATOR FOOTPRINT 2" MIN. COVER (TYP.) 8" MIN. SLAB THICKNESS 1. UNLESS NOTED OTHERWISE, CONCRETE SHALL REACH A MINIMUM COMPRESSIVE STRENGTH OF 3,000 PSI IN 28 DAYS FOR FOUNDATIONS, SLABS, AND CONDUIT ENCASEMENTS. CONCRETE SHALL HAVE A 4" NOMINAL SLUMP AND 4.5-6.5% AIR CONTENT. COMPRESSIVE BREAK TEST TO BE PERFORMED ON FOUNDATION ONLY. #4@12" C/C 2. UNLESS NOTED OTHERWISE, ALL REINFORCING STEEL SHALL BE NEW BILLET STEEL, CONFORMING TO ASTM A-615, GRADE 60, DEFORMED. 4" MIN. SLOPE FINISHED GRADE AWAY FROM FOUNDATION (TYP.) 3. UNLESS NOTED OTHERWISE, ALL DETAILING, FABRICATION AND PLACING OF REINFORCING STEEL SHALL CONFORM TO THE MANUAL OF STANDARD PRACTICE FOR DETAILING REINFORCED CONCRETE STRUCTURES (ACI 318). 4. ALL BAR SPLICES SHALL BE CLASS "B" TENSION SPLICES, UNLESS NOTED OTHERWISE. 5. CHAMFER ALL EXPOSED EXTERNAL CORNERS OF CONCRETE WITH A 34 OTHERWISE. 1 4". FINISHED GRADE (TYP.) COMPACTED SUB GRADE SECTION A-A SCALE: SITE ADDRESS: 7. FLEXIBLE UTILITY CONNECTIONS SHOULD BE USED AT UNDERGROUND TO GENERATOR INTERACTIONS. 8. EQUIPMENT PAD DESIGN BASED ON AN ASSUMED ALLOWABLE CAPACITY OF 2000 PSF AND MAXIMUM SOIL PLASTICITY INDEX OF 27. TESTING AGENCY SHALL FIELD VERIFY CONDITIONS BEFORE PLACEMENT OF CONCRETE. 0 NO. 08/07/13 CONSTRUCTION DRAWINGS DATE SUBJECT 320 Seven Springs Way, Suite 350 Brentwood, TN 37027 T 615-661-7585 013-00178-00 Floyd White Greg Dulnik Travis Leute FOUNDATION DETAILS 9. INSTALL EQUIPMENT ANCHORAGE PER MANUFACTURER'S WRITTEN RECOMMENDATIONS S1 C:\dgn\d0355681\10017514_A&E_ConstructionDrawings_20130510.dwg DATE: Aug 07, 2013 - 3:51pm USER: 14200 3 4" 368-082 SITE NAME: 609 PINEY MOUNTAIN ROAD CHAPEL HILL, NC 27514 ORANGE COUNTY GENERAL NOTES 2" (TYP.) SITE NUMBER: 10017514 ENGINEER: GENERAL NOTES: #2 AWG SOLID TINNED TEST LOOP COVER REMOVABLE BY HAND FINISHED GRADE CABLE AND CONDUIT SCHEDULE WIRES EACH CONDUIT QUANT. SIZE QUANT. SIZE GROUND SIZE 2 2" 3 #3/0 2 1 2" 2 SHIELDED CAT5 1" 1 6 EXISTING TELCO SERVICE FROM LOCAL UTILITY ALARM/CONTROL CONDUIT, 66 BLOCK TO GENERATOR 20A/120VAC POWER FOR BATTERY CHARGER/HEATER, UPC TO GENERATOR 1 #12 #12 AWG CRUSHED ROCK 24" INSIDE, BELOW, AND MIN. AROUND SLEEVE; EXOTHERMIC WELD TO REMAIN VISIBLE 200A/240VAC POWER TO AT&T (GENERATOR TO UPC/ATS) 1 #6 1 3 REMARKS GROUND ROD BONDED TO BURIED GROUND CONDUCTOR UTILIZING T-TYPE EXOTHERMIC WELD CONTRACTOR SHALL COORDINATE INCOMING SERVICES WITH LOCAL UTILITIES PRIOR TO TRENCHING. 2. ALL CONDUCTORS SHALL BE COPPER, 75 DEGREES C RATED, AND CONDUCTOR INSULATION BE THWN OR THHN. 3. ALL TERMINATION SHALL BE LISTED AND IDENTIFIED FOR USE 4. GROUND FAULT PROTECTION REQUIRED FOR UTILITY RECEPTACLES. 5. GENERATOR NEUTRAL SHALL BE GROUNDED AT ONE LOCATION ONLY. REFER TO ONE-LINE NOTE 5. 6. EQUIPMENT LOCATED OUTSIDE OR EXPOSED TO MOISTURE SHALL BE NEMA 3R RATED. 7. CONTRACTOR SHALL USE SCHEDULE 80 PVC CONDUIT THROUGHOUT, UNLESS OTHERWISE NOTED. 8. ALL NEWLY INSTALLED EQUIPMENT SHALL BE RATED "AT 10K AIC" MINIMUM. HIGHER RATINGS SHALL BE REQUIRED WHERE AVAILABLE FAULT CURRENT EXCEEDS THIS VALUE. EXACT FAULT CURRENT AVAILABLE SHALL BE COORDINATED WITH LOCAL UTILITY BASED ON EXACT CONDITIONS (XFMR SIZE, PERCENT IMPEDANCE, LENGTH OF CONDUCTORS, ETC). GROUND WIRE SIZE AS NOTED ON PLANS 6" EXISTING 200A, 120/240V, 1 PHASE UTILITY SERVICE FROM LOCAL UTILITY GROUND ROD, COPPERWELD 5/8" DIAMETER x10'-0" LONG 2 EXISTING 200A SERVICE TO AT&T CONSULTANT: Wireless Services SEAL: GROUND ROD SCALE: N.T.S. O FE SS I O N L 200A/2P at&t A EXISTING 200A, 240V, 1 PHASE METER AND DISCONNECT ON SITE (RACK MOUNTED SEPARATELY OR AT METER CENTER) WH 1" WIDE SLOT FOR GROUND CONDUCTOR; EXTEND 2" ABOVE CONDUCTOR PREPARED FOR: PR CONDUIT MARK 2'-0" x 6" DIAMETER SCHEDULE 40 WHITE PVC 1. SEAL 032960 ELECTRICAL SYMBOLS LEGEND CADWELD TYPE CONNECTION 8/07/13 COMPRESSION TYPE CONNECTION NEW GROUNDING EXISTING 3#3/0, #4G 2-1/2"C TO AT&T EQUIPMENT 1 GROUND RING 3 6 TELCO EXISTING GENERATOR FLANGED INLET ONE LINE DIAGRAM NOTES BY SYMBOL " 200A/ 2P 200A/ 2P GEN. 1 BKR 66 BLOCK UTILITY BKR TVSS PLYWOOD TELCO BACKBOARD, FURNISHED WITH POWER CABINET CAP OFF EXISTING CAMLOCK CONNECTION, LABEL AND LEAVE COILED WITHIN LOAD CENTER EXISTING ASCO AUTOMATIC TRANSFER SWITCH (ATS), 200A, 240V, 2P, 3W, FURNISHED WITH POWER CABINET 3 MGN LCP ": 1. CONTRACTOR SHALL FURNISH AND INSTALL CONDUITS AND POWER CONDUCTORS AS INDICATED FROM GENERATOR TO POWER CABINET. 2. CONTRACTOR SHALL PROVIDE AND INSTALL FEEDS FROM POWER CABINET TO GENERATOR FOR BATTERY CHARGER AND BLOCK HEATER AS INDICATED. 3. AUTOMATIC TRANSFER SWITCH (ATS), FURNISHED BY CUSTOMER AND INSTALLED BY CONTRACTOR. ATS IS 120/240V, 2 POLE, 200A, NEMA 3R WITH SINGLE PHASE SENSING, AUTOMATIC ENGINE STARTING, UL LISTED 1008. 4. THE CONTRACTOR SHALL REFER TO CABINET SPECIFICATIONS FOR ALARM WIRING TO EXTERNAL DEVICES (GENERATOR). INTERIOR ALARMS ARE PRE-WIRED. POWER POWER EXISTING GROUNDING 5. SMGB EXISTING LOAD CENTER PANELBOARD "LCP", 200A, 120/240VAC, 30 POLE, MAIN LUGS ONLY, BOLT ON BREAKERS, RE: 3/E2 6. SITE ADDRESS: POWER & COMMUNICATION CONDUITS 609 PINEY MOUNTAIN ROAD CHAPEL HILL, NC 27514 ORANGE COUNTY 0 NO. EXISTING SERVICE DISCONNECT DO NOT BOND GENERATOR NEUTRAL TO GROUND OR GENERATOR FRAME, GENERATOR NEUTRAL IS BONDED TO SERVICE ENTRANCE NEUTRAL. BOND VIA SOLIDLY GROUNDED ATS (OPEN TRANSITION, FLOATING NEUTRAL AT GENERATOR). ROUTE POWER CONDUCTORS FROM AT&T PANEL TO GENERATOR BATTERY CHARGER & HEATER THROUGH PROPOSED CONDUIT. 368-082 EXISTING AUTOMATIC TRANSFER SWITCH PTS EXISTING UNIVERSAL POWER CABINET (UPC) 4 SITE NUMBER: SITE NAME: EXISTING EQUIPMENT PAD CONCRETE PAD W/ 50KW GENERATOR FA NUMBER: 10017514 #2 AWG BARE TINNED GROUND WIRE TO EXISTING EQUIPMENT GROUND RING. IF MORE THAN 20' FROM EXISTING GROUND RING, INSTALL GROUND ROD (5/8" X 10' SS). ROD SPACING: MIN. 10', MAX. 20'. TOP OF ROD AND GROUND WIRE TO BE BELOW FROST LINE. GROUND GENERATOR PER MANUFACTURERS RECOMMENDATIONS. EXISTING EQUIPMENT PAD GROUND RING (FIELD LOCATE) 3 GROUNDING PLAN SCALE: N.T.S. EXISTING GROUND WIRE 08/07/13 CONSTRUCTION DRAWINGS DATE SUBJECT 320 Seven Springs Way, Suite 350 Brentwood, TN 37027 T 615-661-7585 013-00178-00 Floyd White Greg Dulnik Travis Leute 2 1 ONE LINE DIAGRAM SCALE: N.T.S. ELECTRICAL & GROUNDING DETAILS E1 C:\dgn\d0355681\10017514_A&E_ConstructionDrawings_20130510.dwg DATE: Aug 07, 2013 - 3:51pm USER: 14200 G 200A/2P 2 EMERGENCY GENERATOR SET (EG), 50KW, FURNISHED BY AT&T, REFER TO GENERATOR DRAWINGS FOR ADDITIONAL DETAILS 1 5 ENGINEER: PREPARED FOR: at&t CONSULTANT: Wireless Services SOIL STABILIZER FABRIC COMPACTED GRANULAR TO 95% PROCTOR DENSITY SEAL: 12" 6" WIDE YELLOW WARNING TAPE COMPRESSED BACKFILL, RE: NEC 300-5(f) 12" SCH. 80 PVC AUXILIARY POWER CONDUIT WITH PULL STRINGS SS I O N 8/07/13 SCH. 80 PVC ALARM CONDUIT WITH PULL STRINGS 7 1/2" FE SEAL 032960 COMPACTED SAND SCH. 80 PVC POWER CONDUIT WITH PULL STRINGS O L PR EARTH A MINIMUM COVER REQUIREMENTS 24" MIN/30" MAX PER NEC TABLE 300-5 FA NUMBER: SITE NUMBER: 10017514 368-082 SITE NAME: 18" SITE ADDRESS: 2 609 PINEY MOUNTAIN ROAD CHAPEL HILL, NC 27514 ORANGE COUNTY GENERATOR TRENCH DETAIL SCALE: N.T.S. PROPOSED SUB-PANEL LAYOUT 1 ALARM PIN-OUT SCALE: N.T.S. BREAKER TYPE 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 2P 1P 1P VACANT VACANT VACANT VACANT VACANT VACANT VACANT VACANT VACANT VACANT VACANT ON/ OFF GFCI SIZE (A) CIRCUIT ASSIGNMENT LABEL SOURCE 1 NEW NO 20 3 LIGHT GENERATOR SPACE SPACE SPACE SPACE SPACE SPACE SPACE SPACE SPACE SPACE SPACE SIZE (A) CIRCUIT ASSIGNMENT LABEL BREAKER POSITION BREAKER TYPE 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 2P SOURCE 2 2P SOURCE 3 2P 3G BTS VACANT VACANT VACANT VACANT VACANT VACANT VACANT VACANT VACANT SPACE SPACE SPACE SPACE SPACE SPACE SPACE SPACE SPACE PANEL LAYOUT SCALE: N.T.S. ON/ OFF GFCI 0 NO. 08/07/13 CONSTRUCTION DRAWINGS DATE SUBJECT 320 Seven Springs Way, Suite 350 Brentwood, TN 37027 T 615-661-7585 013-00178-00 Floyd White Greg Dulnik Travis Leute ELECTRICAL & GROUNDING DETAILS E2 C:\dgn\d0355681\10017514_A&E_ConstructionDrawings_20130510.dwg DATE: Aug 07, 2013 - 3:51pm USER: 14200 PROPOSED 20AMP BREAKER FOR NEW AT&T GENERATOR BREAKER POSITION ENGINEER: NOTES TO SUBCONTRACTOR: 4. POWER WIRING SIZE SHALL NOT BE SMALLER THAN #12 AWG. 5. ALL WIRING SHALL BE COPPER. ALUMINUM WILL NOT BE ACCEPTABLE. ALL POWER CIRCUITS SHALL CONTAIN A GROUND WIRE. 6. PHASE MARKINGS TO BE USED AT POWER CONDUCTOR TERMINATIONS. 7. CONTRACTOR SHALL INSURE INTEGRITY IS MAINTAINED WHEN INSTALLING CONDUIT AND WIRING. 8. INSTALL PULL STRING IN ALL CONDUIT. 9. FOR ROOFTOP INSTALLS AND BUILD-OUTS, CONDUITS INSIDE BUILDING AND ON ROOF SHALL BE RGS, UNLESS OTHERWISE NOTED. FOR RAW LAND SITES AND CO-LOCATES, PVC SCHEDULE 80 SHALL BE UTILIZED UNLESS NOTED OTHERWISE. SPECIFICATIONS: 2. 3. 4. 5. 6. IT IS THE INTENTION OF THESE DRAWINGS TO SHOW THE COMPLETED INSTALLATION. THE SUBCONTRACTOR SHALL BE RESPONSIBLE FOR ALL TEMPORARY BRACING, SHORING, TIES, FORM WORK, ETC. IN ACCORDANCE WITH ALL NATIONAL, STATE AND LOCAL ORDINANCES TO SAFELY EXECUTE ALL WORK AND SHALL BE RESPONSIBLE FOR SAME. ALL WORK SHALL BE IN ACCORDANCE WITH LOCAL CODES. THE SUBCONTRACTOR SHALL USE ADEQUATE NUMBER OF SKILLED WORKMAN WHO ARE THOROUGHLY TRAINED AND EXPERIENCED IN THE NECESSARY CRAFTS AND WHO ARE COMPLETELY FAMILIAR WITH THE SPECIFIED REQUIREMENTS AND METHOD NEEDED FOR PROPER PERFORMANCE OF THE WORK. GENERAL 1. 2. ALL WIRING AND EQUIPMENT SHOWN ON ELECTRICAL SHEETS SHALL BE FURNISHED AND INSTALLED UNDER ELECTRICAL PORTION OF CONTRACT UNLESS OTHERWISE NOTED. 4. UNINTERRUPTED ELECTRICAL SERVICE FOR EXISTING EQUIPMENT SHALL BE MAINTAINED DURING THE INSTALLATION OF THE WORK DESCRIBED UNDER THESE DOCUMENTS. TEMPORARY EQUIPMENT, CABLES AND WHATEVER ELSE IS NECESSARY SHALL BE PROVIDED AS REQUIRED TO MAINTAIN ELECTRICAL SERVICE. TEMPORARY SERVICE FACILITIES, IF REQUIRED AT ANY TIME, SHALL NOT BE DISCONNECTED OR REMOVED UNTIL NEW SERVICE EQUIPMENT IS IN PROPER OPERATION. IF ANY SERVICE OR SYSTEM MUST BE INTERRUPTED, THE CONTRACTOR SHALL REQUEST PERMISSION IN WRITING STATING THE DATE, TIME, ETC. THE SERVICE WILL BE INTERRUPTED AND THE AREAS AFFECTED. THIS REQUEST SHALL BE MACE IN SUFFICIENT TIME FOR PROPER ARRANGEMENTS TO BE MADE. WRITTEN PERMISSION SHALL BE OBTAINED FROM THE OWNER BEFORE INTERRUPTING ELECTRICAL SERVICES. ALL WORK SHALL BE ACCOMPLISHED IN ACCORDANCE WITH ALL LOCAL, STATE AND FEDERAL CODES OR ORDINANCES. THE MOST STRINGENT CODE WILL APPLY IN THE CASE OF DISCREPANCIES OR DIFFERENCES IN THE CODE REQUIREMENTS. 5. 6. 7. 8. COORDINATE NEW WORK WITH OTHER TRADES AND VERIFY EXISTING CONDITIONS TO AVOID INTERFERENCE. IN CASE OF INTERFERENCE, AT&T MOBILITY'S REPRESENTATIVE WILL DECIDE WHICH WORK IS TO BE RELOCATED, REGARDLESS OF WHICH WAS FIRST INSTALLED. THE INSTALLATION MUST COMPLY WITH NEC AND ALL FEDERAL, STATE AND LOCAL RULES AND REGULATIONS. THE DRAWINGS ARE DIAGRAMMATIC AND INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS AND EQUIPMENT UNLESS OTHERWISE DEFINED BY DIMENSIONS OR DETAILS. EXACT EQUIPMENT LOCATIONS AND RACEWAY ROUTING SHALL BE GOVERNED BY ACTUAL FIELD CONDITIONS AND/OR DIRECTIONS FOR AT&T MOBILITY'S REPRESENTATIVE. CUSTOMER SHALL PAY ALL PERMIT AND FEES REQUIRED. at&t 10. MAINTAIN MINIMUM 1'-0" VERTICAL AND 1'-0" HORIZONTAL SEPARATION FROM ANY MECHANICAL GAS PIPING. 11. ALL WIRING ROUTED IN PLENUM TO BE PLENUM RATED OR IN METALLIC FLEX (LIQUIDTITE) CONDUIT. CONSULTANT: EQUIPMENT 1. EQUIPMENT/PARTS CONNECTED TO EXISTING PANELS, DUCTS, ETC. SHALL MATCH THE CHARACTERISTICS (A/C, V, A) OF THAT EQUIPMENT. 2. ALL ELECTRICAL EQUIPMENT OUTSIDE SHALL BE NEMA OR 3R RATED. GROUNDING 1. ALL GROUND CONNECTIONS TO BUILDING SHALL BE MADE USING TWO-HOLE CONNECTORS. PROVIDE STAINLESS STEEL BOLTS AND LOCK WASHERS ON ALL MECHANICAL GROUND CONNECTIONS. 2. ALL EQUIPMENT SURFACES TO BE BONDED TO GROUNDING SYSTEM SHALL BE STRIPPED OF ALL PAINT AND DIRT. CONNECTIONS TO VARIOUS METALS SHALL BE OF A TYPES AS TO NOT CAUSE A GALVANIC OR CORROSIVE REACTION. AREA SHALL BE REPAINTED FOLLOWING BONDING. 3. ANY METALLIC ITEM WITHIN 6' OF GROUND CONDUCTORS MUST BE CONNECTED TO THE GROUNDING SYSTEM. 4. EXTERIOR, ABOVE GRADE GROUND CONNECTIONS SHALL BE FURNISHED WITH A LIBERAL PROTECTIVE COATING OF ANTI-OXIDE COMPOUND. 5. ALL MATERIALS AND LABOR REQUIRED FOR THE GROUNDING SYSTEM AS INDICATED ON THE PLANS AND DETAILS, AND AS DESCRIBED HEREIN SHALL BE FURNISHED BY THE SUBCONTRACTOR UNLESS OTHERWISE NOTED. Wireless Services SEAL: O FE SS I O N SEAL 032960 8/07/13 9. 9. ANY DAMAGE TO THE ADJACENT PROPERTIES WILL BE CORRECTED AT THE SUBCONTRACTOR'S EXPENSE TO THE SATISFACTION OF THE LANDOWNER AND THE ENGINEER. THE COMPLETE BID PACKAGE INCLUDES THESE CONSTRUCTION DRAWINGS ALONG WITH THE SPECIFICATIONS, SUBCONTRACTOR IS RESPONSIBLE FOR REVIEW OF TOTAL BID PACKAGE PRIOR TO BID SUBMITTAL. 10. SUBCONTRACTOR SHALL VERITY LOCATION OF ALL EXISTING UTILITIES WITHIN CONSTRUCTION LIMITS PRIOR TO CONSTRUCTION. 11. THE SUBCONTRACTOR IS RESPONSIBLE FOR MAINTAINING POSITIVE DRAINAGE ON THE SITE AT ALL TIMES. SILT AND EROSION CONTROL SHALL BE MAINTAINED ON THE DOWNSTREAM SIDE OF THE SITE AT ALL TIMES. ANY DAMAGE TO ADJACENT PROPERTIES WILL BE CORRECTED AT THE SUBCONTRACTOR'S EXPENSE. 12. PERMITS: THE SUBCONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING ALL REQUIRED PERMITS, INSPECTIONS, CERTIFICATES, ETC. THE CUSTOMER WILL INCUR ALL COSTS. 13. RECORD DRAWINGS: MAINTAIN A RECORD OF ALL CHANGES, SUBSTITUTIONS BETWEEN WORK AS SPECIFIED AND INSTALLED. RECORD CHANGES ON A CLEAN SET OF CONTRACT DRAWING WHICH SHALL BE TURNED OVER TO THE CONSTRUCTION MANAGER UPON COMPLETION OF THE PROJECT. 14. THE PLANS SHOW SOME KNOWN SUBSURFACE STRUCTURES, ABOVE GROUND STRUCTURES AND/OR EXISTING UTILITIES BELIEVED TO BE IN THE WORKING AREA. IT IS THE RESPONSIBILITY OF THE SUBCONTRACTOR TO VERIFY ALL UTILITIES, PIPELINES AND OTHER STRUCTURES SHOWN OR NOT SHOWN ON THESE PLANS. THE SUBCONTRACTOR SHALL CONTACT IN INDIANA (811) OR (800) 382-5544 BEFORE DIGGING OR DRILLING. ANY DAMAGE TO EXISTING UTILITIES SHALL BE REPAIRED TO THE SATISFACTION OF THE OWNER AND ENGINEER AT THE SUBCONTRACTOR'S EXPANSE. 10. CONTRACTOR SHALL REVIEW PLANS, DETAILS AND SPECIFICATIONS IN DETAIL AND ADJUST WORK TO CONFIRM WITH ACTUAL SITE CONDITIONS SO THAT ELECTRICAL DEVICES AND EQUIPMENT WILL BE PROPERLY LOCATED AND READILY ACCESSIBLE. QUANTITIES LISTED IN MATERIAL LISTS ONT HE DRAWINGS ARE FOR INFORMATION ONLY. THE CONTRACTOR SHALL PROVIDE HIS OWN TAKEOFF FOR MATERIAL QUANTITY AND TYPES BASED ON ACTUAL SITE CONDITIONS. IN ADDITION, CONTRACTOR SHALL PROVIDE ALL NECESSARY MATERIALS TO INSTALL EQUIPMENT FURNISHED BY AT&T MOBILITY OR ITS SUPPLIERS. ALL ITEMS NOT SPECIFICALLY MENTIONED HEREIN OR SHOWN ON THE CONTRACT DRAWINGS, BUT WHICH ARE OBVIOUSLY NECESSARY TO MAKE A COMPLETE WORKING INSTALLATION, SHALL BE INCLUDED. 11. THE CONTRACTOR OR BIDDER SHALL BEAR THE RESPONSIBILITY OF NOTIFYING (IN WRITING) AT&T MOBILITY'S REPRESENTATIVE OF ANY CONFLICTS PRIOR TO THE SUBMISSION OF CONTRACTOR'S PROPOSAL OR CONTRACTOR SHALL PRICE THE MORE COSTLY OR EXTENSIVE WORK, UNLESS DIRECTED IN WRITING OTHERWISE. 12. ALL FLOORS WHERE PENETRATIONS ARE REQUIRED IN BUILDING ARE TO BE CORE DRILLED AND THEN FIREPROOFED. WIRING/CONDUIT 15. ALL MATERIAL SHALL BE FURNISHED AND WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE PROJECT SPECIFICATIONS. 1. PROVIDE PULL BOXES AND JUNCTION BOXES WHERE SHOWN OR AS REQUIRED BY CODE SUCH THAT NO MORE THAN THE EQUIVALENT OF FOUR QUARTER BENDS (360 DEGREES TOTAL) EXIST IN/ON CONDUIT RUN. 2. ALL POWER AND CONTROL/INDICATION WIRING SHALL BE TYPE THHN/THWN 800V RATED 75 DEGREES CELSIUS, UNLESS NOTED OTHERWISE. 3. CONDUIT BENDS SHALL BE MADE IN ACCORDANCE WITH NEC TABLE 346-10. NO RIGHT ANGLE DEVICE OTHER THAN STANDARD CONDUIT ELBOWS WITH 12" MINIMUM INSIDE SWEEPS FOR ALL CONDUITS 2" OR LARGER. 16. SUBCONTRACTOR SHALL BE RESPONSIBLE FOR REPAIRING ANY DAMAGE CAUSED BY THE CONSTRUCTION OPERATION. 17. SUBCONTRACTOR SHALL REMOVE ALL TRASH AND DEBRIS FROM THE SITE ON A DAILY BASIS. 18. INFORMATION SHOWN ON THESE DRAWINGS WAS OBTAINED FROM DRAWING PROVIDED BY THE SITE OWNER. SUBCONTRACTOR SHALL NOTIFY AT&T MOBILITY OF ANY DISCREPANCIES PRIOR TO ORDERING MATERIAL OR PRECEDING WITH CONSTRUCTION. FA NUMBER: SITE NUMBER: 10017514 368-082 SITE NAME: 6. EXACT LOCATION OF GROUND CONNECTION POINTS SHALL BE DETERMINED IN FIELD. ADJUST LOCATIONS INDICATED ON THE PLANS ACCORDING TO ACTUAL EQUIPMENT LOCATIONS TO KEEP THE GROUND CONNECTIONS CABLES AS SHORT AS POSSIBLE. 7. PROVIDE ALL ELECTRICAL SYSTEM AND EQUIPMENT GROUNDS AS REQUIRED BY THE CURRENT EDITION OF THE NATIONAL ELECTRICAL CODE AND THE CURRENT EDITION OF THE NATIONAL ELECTRICAL SAFETY CODE. BONDING JUMPERS WITH APPROVED GROUND FITTINGS SHALL BE INSTALLED AT ALL RACEWAYS, EQUIPMENT ENCLOSURES, PULL BOXES, ETC. TO MAINTAIN GROUND CONTINUITY WHERE REQUIRED BY CODE. 8. ALL EQUIPMENT GROUND CONDUCTORS SHALL BE TIN COATED, #2 AWG COPPER UNLESS NOTED OTHERWISE ON THE DRAWINGS. SITE ADDRESS: 609 PINEY MOUNTAIN ROAD CHAPEL HILL, NC 27514 ORANGE COUNTY GROUNDING 1. 2. 3. 4. THE CONTRACTOR, UPON COMPLETION OF HIS WORK, SHALL PROVIDE AS-BUILT DRAWINGS. INFORMATION SHOULD BE GIVEN TO THE GENERAL CONTRACTOR FOR INCLUSION IN FINAL AS-BUILT SURVEY DOCUMENTS TO BE GIVEN TO THE OWNER. CONTRACTOR SHALL SUPPLY DOCUMENTATION ATTESTING TO THE COMPLETE GROUND SYSTEM'S RESISTIVITY (MAX. 5 OHMS). AN ELECTRICAL INSPECTION SHALL BE MADE BY AN INSPECTING AGENCY APPROVED BY AT&T MOBILITY'S REPRESENTATIVE. CONTRACTOR SHALL COORDINATE ALL INSPECTIONS AND OBTAIN POWER COMPANY APPROVAL. CONTRACTOR SHALL HAVE ATS AND GENERATOR RELAY INSTALLATION AND CONNECTIONS INSPECTED BY OTHERS TO ENSURE THAT UL LISTING FOR THAT EQUIPMENT IS NOT VOIDED. 0 NO. 08/07/13 CONSTRUCTION DRAWINGS DATE SUBJECT 320 Seven Springs Way, Suite 350 Brentwood, TN 37027 T 615-661-7585 013-00178-00 Floyd White Greg Dulnik Travis Leute GENERAL NOTES SP1 C:\dgn\d0355681\10017514_A&E_ConstructionDrawings_20130510.dwg DATE: Aug 07, 2013 - 3:51pm USER: 14200 8. ALL MATERIALS SHALL BE FURNISHED AND WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE APPLICABLE SECTIONS OF THE STANDARDS REFERENCED BELOW: 9.1. ANSI (AMERICAN NATIONAL STANDARDS INSTITUTE) 9.2. ASTM (AMERICAN SOCIETY FOR TESTING MATERIALS) 9.3. ETL (ELECTRICAL TESTING LABORATORY) 9.4. ICEA (INSULATED CABLE ENGINEERS ASSOCIATION) 9.5. IEEE (INSTITUTE OF ELECTRICAL AND ELECTRONIC ENGINEERS) 9.6. NBFU (NATIONAL BOARD OF FIRE UNDERWRITERS) 9.7. NESC (NATIONAL ELECTRICAL SAFETY CODE) 9.8. NEMA (NATIONAL ELECTRICAL MANUFACTURER'S ASSOCIATION) 9.9. UL (UNDERWRITERS LABORATORY) PREPARED FOR: L ALL WORK SHALL COMPLY WITH OSHA AND STATE SAFETY REQUIREMENTS. PROCEDURES FOR THE PROTECTION OF EXCAVATIONS, EXISTING CONSTRUCTION AND UTILITIES SHALL BE ESTABLISHED PRIOR TO FOUNDATION INSTALLATION. IF FAA LIGHTING AND MARKING IS PRESENT ON SITE AND IS POWERED BY ELECTRICAL SERVICE THAT IS TO BE INTERRUPTED, IT IS THE SUBCONTRACTOR'S RESPONSIBILITY TO MAINTAIN THE NECESSARY LIGHTS AND NOTIFY THE PROPER AUTHORITIES IN THE EVENT OF A PROBLEM. COORDINATE LOCATION AND REQUIREMENTS FOR ELECTRICAL SERVICE WITH THE PROPERTY REPRESENTATIVE, AT&T MOBILITY AND UTILITY COMPANIES. ROUTING OF CONDUITS MAY BE MODIFIED TO MEET SITE REQUIREMENTS. EXACT CONDUIT ROUTING TO BE DETERMINED IN THE FIELD. 3. CONSTRUCTION SUBCONTRACTOR AGREES THAT IN ACCORDANCE WITH GENERALLY ACCEPTED CONSTRUCTION PRACTICES, CONSTRUCTION, SUBCONTRACTORS WILL BE REQUIRED TO ASSUME SOLE AND COMPLETE RESPONSIBILITY FOR JOB SITE CONDITIONS DURING THE COURSE OF CONSTRUCTION OF THE PROJECT, INCLUDING THE SAFETY OF ALL PERSONS AND PROPERTY. THAT IS REQUIREMENT SHALL BE MADE TO APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS AND CONSTRUCTION SUBCONTRACTOR FURTHER AGREES TO INDEMNIFY AND HOLD DESIGN ENGINEER HARMLESS FROM ANY AND ALL LIABILITY, REAL OR ALLEGED, IN CONNECTION WITH PERFORMANCE OF WORK ON THIS PROJECT. SITE GROUNDING SHALL COMPLY WITH AT&T MOBILITY WIRELESS SERVICES TECHNICAL SPECIFICATIONS FOR FACILITY GROUNDING FOR CELL SITE STANDARDS, LATEST EDITION, AND COMPLY WITH AT&T MOBILITY TOWERS GROUNDING CHECKLIST, LATEST VERSION. WHEN NATIONAL AND LOCAL GROUNDING CODES ARE MORE STRINGENT, THEY SHALL GOVERN. COORDINATE LOCATION AND PROPER REQUIREMENTS OF ALL EQUIPMENT WITH AT&T MOBILITY AND EQUIPMENT SUPPLIES PRIOR TO INSTALLATION. A 7. THE GENERAL SUBCONTRACTOR MUST VERIFY ALL DIMENSIONS, CONDITIONS AND ELEVATIONS BEFORE STARTING WORK. ALL DISCREPANCIES SHALL BE RESOLVED BEFORE PROCEEDING WITH THE WORK. ALL WORK SHALL BE PERFORMED IN A WORKMANLIKE MANNER IN ACCORDANCE WITH ACCEPTED CONSTRUCTION PRACTICES. PR 1.