What is SubDrive
SubDrive is Franklin Electric’s variable frequency drive constant pressure system. SubDrive
QuickPAK comprises of a Pump, Motor, Drive, Pressure tank and Sensor all in one quick and
easy package. SubDrive controllers provide constant pressure by continually monitoring and
adjusting the pump speed to meet water demands.
SubDrive also eliminates pressure fluctuations during long running applications such
as reticulation/irrigation systems and other domestic and industrial uses.
Applications




Residential Water Systems
• City-like water pressure
• Compact design saves space
in garages and sheds
L andscape Irrigation and Sprinkler
Systems
• Even distribution of water in zones
• Eliminates need for separate system
Features and benefits

Constant water pressure with a wide
range of settings

Soft start feature eliminates water
hammer and increases motor life

Works with small pressure tanks or
with larger tanks already in place

Water Treatment Systems
• More efficient back-flushing
• Eliminates need for multiple pumps
S mart Reset® technology allows well
recovery before restarting the pump

S ingle-phase input power with
three-phase motor performance
Geothermal Heating Systems

E
xcellent radio frequency
interference shielding

W
ide operating voltage (190-260V)
Built-in Diagnostics and Protection
The SubDrive controller include diagnostic features and built-in protection
for conditions that would be harmful to the system.
This protection includes:



Surge protection
Underload
Undervoltage




Locked pump
Open circuit
Short circuit
Overheated controller
75
5
5
W
A
RR
Pressure
Tank
*
AN
T
SubDrive
SubDrive System
Pressure
Sensor
All in one easy and quick package
to get you pumping quickly.



Pump

Power
Supply


Motor

Model
YEAR
Y
SubDrive
Order number
SDQP75-25-160
93800705
SDQP75-30-135
93801005
SDQP75-45-105
93801505
SDQP75-60-83
93802005
SDQP75-70-82
93802505
SDQP75-100-55
93803505
18L Tank
106435103
SubDrive Pump
SubDrive Motor
SubDrive Controller
Pressure Gauge
Pressure Sensor
Splice Kit
18 Litre Pressure Tank
Also available:
8L to 80L Pressure Tanks
 Electrical Drop Cable
 Bore Accessories

* 5 Year Warranty
All SubDrive components:
pump, motor, drive and tank
are covered.
• All pump ends up to 70 PM feature TriSeal hydraulics
• For river, creek and dam installations, recommend 316SS 4” motors with mechanical seal
with price adder.
• SubDrive 75 enclosure is rated IP20 for indoor installation. Outdoor enclosure rated IP55
available with price adder.
For more information go to constantpressure.com
Constant Pressure – SubDrive QuickPAK
SubDrive 75 25 lpm .75 Hp
Curve #: 109099101m
Date: 3/2/10
SDQP75-25-160
250
Total Head (M)
200
150
100
Recommended Operating Range
50
0
5
10
15
20
25
30
35
40
45
50
55
Flow (lpm)
25 LPM – 1.5m³/h
Depth to Pumping Water Level, or Lift, in Metres Shaded Areas Indicate Most Efficient Performance
Metres
1.1
0
5
10
20
30
40
50
60
70
80
90
100
110
120
130
140
150
160
170
180
190
Shut-off
Metres
5
10
15
49
48
46
44
42
40
37
35
32
29
26
23
19
16
12
49
47
45
43
41
39
36
34
31
28
25
21
18
14
49
48
46
44
42
40
37
35
32
29
26
23
19
16
12
223
218
213
20
25
30
35
49
47
45
43
41
39
36
34
31
28
25
21
18
14
49
48
46
44
42
40
37
35
32
29
26
23
19
16
12
49
47
45
43
41
39
36
34
31
28
25
21
18
14
49
48
46
44
42
40
37
35
32
29
26
23
19
16
12
208
203
198
193
40
49
47
45
43
41
39
36
34
31
28
25
21
18
14
10
188
45
49
48
46
44
42
40
37
35
32
29
26
23
19
16
12
183
50
49
49
47
45
43
41
39
36
34
31
28
25
21
18
14
178
60
80
100 120 140 160 180
49
48
47
45
43
41
39
36
34
31
28
25
21
18
14
45
44
43
41
39
36
34
31
28
25
21
18
14
41
40
39
36
34
31
28
25
21
18
14
36
35
34
31
28
25
21
18
14
31
29
28
25
21
18
14
25
23
21
18
14
18
16
14
168
148
128
108
88
68
48
Shut Off Head 228 metres
Motor
kW
NOTE: Running outside of ‘Recommenced Operating Range’ for short periods of time is permissible.
Actual maximum performance of the SubDrive QuickPAK system is power limited by the SubDrive unit. This limit is based on the
maximum allowable AMP load of the submersible motor. The result is that in some installations an 80 Hz speed may not be attained.
Flow Rate Units = LPM
4
Constant Pressure – SubDrive QuickPAK
SubDrive 75 30 lpm .75 HP
Curve #: 109100101m
Date: 3/2/10
Total Head (M)
SDQP75-30-135
180
170
160
150
140
130
120
110
100
90
80
70
60
50
40
30
20
10
0
Recommended Operating Range
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
Flow (lpm)
30 LPM – 2m³/h
Depth to Pumping Water Level, or Lift, in Metres Shaded Areas Indicate Most Efficient Performance
Metres
1.1
0
5
10
20
30
40
50
60
70
80
90
100
110
120
130
140
150
160
Shut-off
Metres
5
63
59
56
52
48
44
39
34
29
24
18
173
10
15
64
61
57
54
50
46
41
37
32
27
21
63
59
56
52
48
44
39
34
29
24
18
168
163
20
25
64
61
57
54
50
46
41
37
32
27
21
63
59
56
52
48
44
39
34
29
24
18
158
153
30
35
64
61
57
54
50
46
41
37
32
27
21
63
59
56
52
48
44
39
34
29
24
18
148
143
40
45
64
61
57
54
50
46
41
37
32
27
21
64
63
59
56
52
48
44
39
34
29
24
18
138
133
50
60
80
100
120
140
64
63
61
57
54
50
46
41
37
32
27
21
61
59
57
54
50
46
41
37
32
27
21
54
52
50
46
41
37
32
27
21
46
44
41
37
32
27
21
37
35
32
27
21
27
24
21
128
118
98
78
58
38
Shut Off Head 177.5 metres
Motor
kW
NOTE: Running outside of ‘Recommenced Operating Range’ for short periods of time is permissible.
Actual maximum performance of the SubDrive QuickPAK system is power limited by the SubDrive unit. This limit is based on the
maximum allowable AMP load of the submersible motor. The result is that in some installations an 80 Hz speed may not be attained.
Flow Rate Units = LPM
5
Constant Pressure – SubDrive QuickPAK
SubDrive 75 45 lpm .75 Hp
Curve #: 109101101m
Date:3/2/10
SDQP75-45-105
150
140
130
120
110
Total Head (M)
100
90
80
70
60
Recommended Operating Range
50
40
30
20
10
0
10
20
30
40
50
60
70
80
90
100
110
Flow (lpm)
45 LPM – 3m³/h
Depth to Pumping Water Level, or Lift, in Metres Shaded Areas Indicate Most Efficient Performance
Metres
1.1
0
5
10
20
30
40
50
60
70
80
90
100
110
120
Shut-off
Metres
5
10
92
86
79
71
63
54
45
33
89
82
75
67
59
50
39
26
128
123
15
20
92
86
79
71
63
54
45
33
89
82
75
67
59
50
39
26
118
113
25
30
92
86
79
71
63
54
45
33
89
82
75
67
59
50
39
26
108
103
35
40
92
86
79
71
63
54
45
33
92
89
82
75
67
59
50
39
26
98
93
45
50
60
80
100 120
92
89
86
79
71
63
54
45
33
89
86
82
75
67
59
50
39
26
82
79
75
67
59
50
39
26
67
63
59
50
39
26
50
45
39
26
26
88
83
73
53
33
13
Shut Off Head 133 metres
kW
NOTE: Running outside of ‘Recommenced Operating Range’ for short periods of time is permissible.
Actual maximum performance of the SubDrive QuickPAK system is power limited by the SubDrive unit. This limit is based on the
maximum allowable AMP load of the submersible motor. The result is that in some installations an 80 Hz speed may not be attained.
Flow Rate Units = LPM
6
Constant Pressure – SubDrive QuickPAK
SubDrive 75 60 lpm .75 Hp
Curve #: 109164101m
Date: 3/2/10
SDQP75-60-83
100
90
80
Total Head (M)
70
60
50
Recommended Operating Range
40
30
20
10
0
10
20
30
40
50
60
70
80
90 100 110 120 130 140 150
Flow (lpm)
60 LPM – 3.5m³/h
kW
Metres
1.1
0
5
10
20
30
40
50
60
70
80
90
Shut-off
Metres
5
10
128
119
107
92
76
58
123
114
100
84
68
42
91
86
15
20
128
119
107
92
76
58
123
114
100
84
68
42
81
76
25
30
128
119
107
92
76
58
128
123
114
100
84
68
42
71
66
35
40
45
50
60
80
128
123
119
107
92
76
58
123
119
114
100
84
68
42
119
114
107
92
76
58
114
107
100
84
68
42
100
92
84
68
42
68
58
42
61
56
51
46
36
16
Shut Off Head 95.85 metres
Depth to Pumping Water Level, or Lift, in Metres Shaded Areas Indicate Most Efficient Performance
NOTE: Running outside of ‘Recommenced Operating Range’ for short periods of time is permissible.
Actual maximum performance of the SubDrive QuickPAK system is power limited by the SubDrive unit. This limit is based on the
maximum allowable AMP load of the submersible motor. The result is that in some installations an 80 Hz speed may not be attained.
Flow Rate Units = LPM
7
Constant Pressure – SubDrive QuickPAK
SubDrive 75 70 lpm .75 Hp
Curve #: 109103101m
Date: 1/19/10
SDQP75-70-82
110
100
90
Total Head (M)
80
70
60
50
Recommended Operating Range
40
30
20
10
0
10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160
Flow (lpm)
70 LPM – 4m³/h
kW
Metres
1.1
0
5
10
20
30
40
50
60
70
80
90
Shut-off
Metres
5
10
15
148
136
128
115
99
82
63
141
132
122
107
90
73
148
136
128
115
99
82
63
96
91
86
20
25
30
35
40
45
50
60
80
148
141
132
122
107
90
73
148
141
136
128
115
99
82
64
141
136
132
122
107
90
73
136
132
128
115
99
82
64
132
128
122
107
90
73
128
122
115
99
82
64
122
115
107
90
73
107
99
90
73
73
64
81
76
71
66
61
56
51
41
21
Shut Off Head 101 metres
Depth to Pumping Water Level, or Lift, in Metres Shaded Areas Indicate Most Efficient Performance
NOTE: Running outside of ‘Recommenced Operating Range’ for short periods of time is permissible.
Actual maximum performance of the SubDrive QuickPAK system is power limited by the SubDrive unit. This limit is based on the
maximum allowable AMP load of the submersible motor. The result is that in some installations an 80 Hz speed may not be attained.
Flow Rate Units = LPM
8
Constant Pressure – SubDrive QuickPAK
SubDrive 75 100-55
Curve #: 108377101-3m
Date: 10/16/08
SDQP75-100-55
80
70
Total Head (M)
60
50
40
30
Recommended Operating Range
20
10
0
50
100
150
200
250
Flow (lpm)
100 LPM – 6m³/h
kW
Metres
1.1
0
5
10
20
30
40
50
60
70
Shut-off
Metres
5
227
183
154
125
97
68
72
10
15
20
25
30
35
40
45
50
60
227
201
168
140
110
83
227
201
183
154
125
97
68
201
183
168
140
111
83
183
168
154
125
97
69
168
154
140
111
83
154
140
125
97
69
140
125
111
83
125
111
97
69
111
97
83
83
69
67
62
57
52
47
42
37
32
27
17
Shut Off Head 77.0
metres
Depth to Pumping Water Level, or Lift, in Metres Shaded Areas Indicate Most Efficient Performance
NOTE: Running outside of ‘Recommenced Operating Range’ for short periods of time is permissible.
Actual maximum performance of the SubDrive QuickPAK system is power limited by the SubDrive unit. This limit is based on the
maximum allowable AMP load of the submersible motor. The result is that in some installations an 80 Hz speed may not be attained.
Flow Rate Units = LPM
9
Constant Pressure – SubDrive QuickPAK
Notes
SubDrive
150
SubDrive
SubDrive System
Pressure
Tank
Pressure
Sensor
All in one easy and quick package
to get you pumping quickly.



Pump

Power
Supply


Motor

Model
Order number
SDQP150-25-300
93800790
SDQP150-30-245
93801090
SDQP150-45-195
93801590
SDQP150-60-155
93802090
SDQP150-65-137
93802590
SDQP150-100-94
93803590
SDQP150-150-65
93804590
35L Tank
106435104
SubDrive Pump
SubDrive Motor
SubDrive Controller
Pressure Gauge
Pressure Sensor
Splice Kit
35 Litre Pressure Tank
Also available:
8L to 80L Pressure Tanks
 Electrical Drop Cable
 Bore Accessories

5 Year Warranty
All SubDrive components:
pump, motor, drive and tank
are covered.
• All pump ends up to 70 PM feature TriSeal hydraulics
• For river, creek and dam installations, recommend 316SS 4” motors with mechanical seal
with price adder.
• SubDrive 150 enclosure is rated IP55 for outdoor/indoor installation.
For more information go to constantpressure.com
Constant Pressure – SubDrive QuickPAK
SubDrive 150 1.5 Hp 25 lpm
Curve #: 109113101m
Date: 9/8/09
SDQP150-25-300
450
400
350
Total Head (M)
300
250
200
Recommended Operating Range
150
100
50
0
5
10
15
20
25
30
Flow (lpm)
12
35
40
45
50
55
Constant Pressure – SubDrive QuickPAK
Constant Pressure – SubDrive QuickPAK
25 LPM – 1m³/h
Depth to Pumping Water Level, or Lift, in Metres Shaded Areas Indicate Most Efficient Performance
kW
Metres
2.2
0
5
10
20
30
40
50
60
70
80
90
100
110
120
130
140
150
160
170
180
190
Shut-off Metres
5
10
15
20
25
49
48
47
46
45
44
43
42
41
40
39
48
47
46
45
44
43
42
41
40
39
38
49
48
47
46
45
44
43
42
41
40
39
38
48
47
46
45
44
43
42
41
40
39
38
37
49
48
47
46
45
44
43
42
41
40
39
38
36
5
10
15
20
25
30
35
40
45
48
47
46
45
44
43
42
41
40
39
38
37
36
49
48
47
46
45
44
43
42
41
40
39
38
36
35
48
47
46
45
44
43
42
41
40
39
38
37
36
34
49
48
47
46
45
44
43
42
41
40
39
38
36
35
34
30
35
40
45
50
60
80
100
48
48
47
46
45
44
43
42
41
40
39
38
37
36
35
33
32
31
29
28
26
100
48
47
46
45
44
43
42
41
40
39
38
37
36
34
33
48
47
46
45
44
43
42
41
40
39
38
37
36
35
33
32
48
47
46
45
44
43
42
41
40
39
38
37
36
35
33
32
31
29
50
60
80
Depth to Pumping Water Level, or Lift, in Metres Shaded Areas Indicate Most Efficient Performance
Metres
2.2
0
5
10
20
30
40
50
60
70
80
90
100
110
120
130
140
150
160
170
180
190
Shut-off Metres
120 140 160 180 200 220 240 260 280 300 320 340 360 380
46
46
45
44
43
42
41
40
39
38
37
36
35
33
32
31
29
28
27
25
24
44
44
43
42
41
40
39
38
37
36
35
33
32
31
29
28
27
25
24
22
20
42
42
41
40
39
38
37
36
35
33
32
31
29
28
27
25
24
22
20
19
17
40
40
39
38
37
36
35
33
32
31
29
28
27
25
24
22
20
19
17
15
13
38
38
37
36
35
33
32
31
29
28
27
25
24
22
20
19
17
15
13
10
36
35
35
33
32
31
29
28
27
25
24
22
20
19
17
15
13
11
33
33
32
31
29
28
27
25
24
22
20
19
17
15
13
11
31
30
29
28
27
25
24
22
20
19
17
15
13
11
28
27
27
25
24
22
20
19
17
15
13
11
25
24
24
22
20
19
17
15
13
11
22
21
20
19
17
15
13
11
19
18
17
15
13
11
15
14
13
11
11
9
120
140
160
180
200
220
240
260
280
300
320
340
360
380
Shut-off 417m
kW
NOTE: Running outside of ‘Recommenced Operating Range’ for short periods of time is permissible.
Actual maximum performance of the SubDrive QuickPAK system is power limited by the SubDrive unit. This limit is based on the
maximum allowable AMP load of the submersible motor. The result is that in some installations an 80 Hz speed may not be attained.
Flow Rate Units = LPM
13
Constant Pressure – SubDrive QuickPAK
SubDrive 150 30 lpm 1.5 Hp
Curve #: 109151101m
Date: 9/8/09
SDQP150-30-245
350
300
Total Head (M)
250
200
150
Recommended Operating Range
100
50
0
5
10
15
20
25
30
35
40
45
Flow (lpm)
14
50
55
60
65
70
75
Constant Pressure – SubDrive QuickPAK
30 LPM – 2m³/h
Depth to Pumping Water Level, or Lift, in Metres Shaded Areas Indicate Most Efficient Performance
kW
Metres
2.2
0
5
10
20
30
40
50
60
70
80
90
100
110
120
130
140
150
160
Shut-off
Metres
5
10
15
20
25
68
66
65
63
62
60
58
56
54
52
67
66
64
63
61
59
57
55
53
51
68
66
65
63
62
60
58
56
54
52
50
67
66
64
63
61
59
57
55
53
51
49
68
66
65
63
62
60
58
56
54
52
50
48
5
10
15
20
25
30
35
40
45
50
60
67
66
64
63
61
59
57
55
53
51
49
46
44
41
67
66
64
63
61
59
57
55
53
51
49
46
44
41
38
50
60
67
66
64
63
61
59
57
55
53
51
49
46
68
66
65
63
62
60
58
56
54
52
50
48
45
67
66
64
63
61
59
57
55
53
51
49
46
44
68
66
65
63
62
60
58
56
54
52
50
48
45
42
30
35
40
45
Depth to Pumping Water Level, or Lift, in Metres Shaded Areas Indicate Most Efficient Performance
Metres
80
100
120
140
160
180
200
220
240
260
280
67
66
66
64
63
61
59
57
55
53
51
49
46
44
41
38
35
32
64
63
63
61
59
57
55
53
51
49
46
44
41
38
35
32
28
25
61
60
59
57
55
53
51
49
46
44
41
38
35
32
28
25
21
18
57
56
55
53
51
49
46
44
41
38
35
32
28
25
21
18
53
52
51
49
46
44
41
38
35
32
28
25
21
18
49
48
46
44
41
38
35
32
28
25
21
18
44
42
41
38
35
32
28
25
21
18
38
36
35
32
28
25
21
18
32
30
28
25
21
18
25
23
21
18
18
16
2.2
0
5
10
20
30
40
50
60
70
80
90
100
110
120
130
140
150
160
80
100
120
140
160
180
200
220
240
260
280
Shut-off
Metres
Shut-off 338m
kW
NOTE: Running outside of ‘Recommenced Operating Range’ for short periods of time is permissible.
Actual maximum performance of the SubDrive QuickPAK system is power limited by the SubDrive unit. This limit is based on the
maximum allowable AMP load of the submersible motor. The result is that in some installations an 80 Hz speed may not be attained.
Flow Rate Units = LPM
15
Constant Pressure – SubDrive QuickPAK
SubDrive 150 45 lpm 1.5 Hp
Curve #: 109115101m
Date:9/8/09
SDQP150-45-195
250
Total Head (M)
200
150
100
Recommended Operating Range
50
0
10
20
30
40
50
60
70
80
90
100
110
Flow (lpm)
45 LPM – 3m³/h
Depth to Pumping Water Level, or Lift, in Metres Shaded Areas Indicate Most Efficient Performance
Metres
2.2
0
5
10
20
30
40
50
60
70
80
90
100
110
120
Shut-off Metres
5
10
15
97
94
91
88
84
81
77
96
92
89
86
83
79
75
97
94
91
88
84
81
77
73
5
10
15
20
25
30
35
96
92
89
86
83
79
75
71
97
94
91
88
84
81
77
73
69
96
92
89
86
83
79
75
71
67
97
94
91
88
84
81
77
73
69
64
20
25
30
35
40
45
50
60
80 100 120 140 160 180 200 220
92
91
89
86
83
79
75
71
67
62
58
53
48
42
86
84
83
79
75
71
67
62
58
53
48
42
36
29
80
100 120 140 160 180 200 220
96
92
89
86
83
79
75
71
67
62
97
94
91
88
84
81
77
73
69
64
60
96
92
89
86
83
79
75
71
67
62
58
97
96
92
89
86
83
79
75
71
67
62
58
53
40
45
50
60
79
77
75
71
67
62
58
53
48
42
36
29
21
71
69
67
62
58
53
48
42
36
29
21
62
60
58
53
48
42
36
29
21
53
50
48
42
36
29
21
42
39
36
29
21
NOTE: Running outside of ‘Recommenced Operating Range’ for short periods of time is permissible.
Actual maximum performance of the SubDrive QuickPAK system is power limited by the SubDrive unit. This limit is based on the
maximum allowable AMP load of the submersible motor. The result is that in some installations an 80 Hz speed may not be attained.
Flow Rate Units = LPM
16
29
25
21
Shut-off 248m
kW
Constant Pressure – SubDrive QuickPAK
SubDrive 150 60 lpm 1.5 Hp
Curve #: 109153101m
Date: 9/8/09
Total Head (M)
SDQP150-60-155
180
170
160
150
140
130
120
110
100
90
80
70
60
50
40
30
20
10
0
Recommended Operating Range
10
20
30
40
50
60
70
80
90 100 110 120 130 140 150
Flow (lpm)
60 LPM – 3.5m³/h
kW
Metres
2.2
0
5
10
20
30
40
50
60
70
80
90
Shut-off
Metres
5
10
15
132
125
120
114
128
122
117
110
132
125
120
114
106
5
10
15
20
25
30
35
128
122
117
110
102
132
125
120
114
106
98
128
122
117
110
102
94
132
125
120
114
106
98
90
20
25
30
35
40
45
50
60
80 100 120 140 160
123 110
120 107
117 103
110 94
103 85
94 76
85 66
76 53
66 32
53
32
128
122
117
110
102
94
85
132
125
120
114
106
98
90
81
128
122
117
110
103
94
85
76
132
128
122
117
110
103
94
85
76
66
40
45
50
60
80
94
90
85
76
66
53
32
76
71
66
53
32
53
44
32
Shut-off 177m
Depth to Pumping Water Level, or Lift, in Metres Shaded Areas Indicate Most Efficient Performance
100 120 140 160
NOTE: Running outside of ‘Recommenced Operating Range’ for short periods of time is permissible.
Actual maximum performance of the SubDrive QuickPAK system is power limited by the SubDrive unit. This limit is based on the
maximum allowable AMP load of the submersible motor. The result is that in some installations an 80 Hz speed may not be attained.
Flow Rate Units = LPM
17
Constant Pressure – SubDrive QuickPAK
SubDrive 150 70 lpm 1.5 Hp
Curve #: 109117101m
Date: 9/8/09
SDQP150-65-137
160
150
140
130
120
110
Total Head (M)
100
90
80
70
Recommended Operating Range
60
50
40
30
20
10
0
10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160
Flow (lpm)
70 LPM – 4m³/h
kW
Metres
2.2
0
5
10
20
30
40
50
60
70
80
90
5
10
15
149
140
132
122
144
136
127
116
149
140
132
122
110
5
10
15
Shut-off
Metres
20
25
30
35
144
136
127
116
104
149
140
132
122
110
98
144
136
127
116
104
92
149
140
132
122
110
98
87
20
25
30
35
40
45
50
60
144
136
127
116
104
92
81
149
140
132
122
110
98
87
74
144
136
127
116
104
92
81
66
149
144
136
127
116
104
93
81
66
38
40
45
50
60
80
100 120 140
136
132
127
117
104
93
81
66
39
117
111
104
93
81
66
39
93
87
81
66
39
66
55
39
80
100
120
140
NOTE: Running outside of ‘Recommenced Operating Range’ for short periods of time is permissible.
Actual maximum performance of the SubDrive QuickPAK system is power limited by the SubDrive unit. This limit is based on the
maximum allowable AMP load of the submersible motor. The result is that in some installations an 80 Hz speed may not be attained.
18
Flow Rate Units = LPM
Shut-off 152m
Depth to Pumping Water Level, or Lift, in Metres Shaded Areas Indicate Most Efficient Performance
Constant Pressure – SubDrive QuickPAK
SubDrive 150 100 lpm 1.5 Hp
Curve #: 109118101m
Date: 9/8/09
SDQP150-100-94
120
110
100
90
Total Head (M)
80
70
60
50
Recommended Operating Range
40
30
20
10
0
50
100
150
200
250
Flow (lpm)
100 LPM – 6m³/h
kW
Metres
2.2
0
5
10
20
30
40
50
60
70
Shut-off
Metres
5
10
15
20
25
30
35
40
45
50
60
80
100
224
217
208
191
169
144
123
224
220
217
208
191
169
144
123
105
220
217
213
200
180
157
133
114
98
217
213
208
191
169
144
123
105
89
213
208
200
181
157
133
114
98
78
208
200
191
169
145
123
105
89
63
200
191
181
157
133
114
98
78
191
181
169
145
123
105
89
63
169
157
145
123
105
89
63
123
114
106
89
63
89
79
63
220
213
200
180
156
133
224
220
213
200
180
156
133
114
5
10
15
20
25
30
35
40
45
50
60
80
100
Shut-off 118m
Depth to Pumping Water Level, or Lift, in Metres Shaded Areas Indicate Most Efficient Performance
NOTE: Running outside of ‘Recommenced Operating Range’ for short periods of time is permissible.
Actual maximum performance of the SubDrive QuickPAK system is power limited by the SubDrive unit. This limit is based on the
maximum allowable AMP load of the submersible motor. The result is that in some installations an 80 Hz speed may not be attained.
Flow Rate Units = LPM
19
Constant Pressure – SubDrive QuickPAK
SubDrive 150 150 lpm 1.5 Hp
Curve #: 109119101m
Date: 9/9/09
SDQP150-150-65
100
90
80
Total Head (M)
70
60
50
Recommended Operating Range
40
30
20
10
0
50
100
150
200
250
300
Flow (lpm)
150 LPM – 9m³/h
Depth to Pumping Water Level, or Lift, in Metres Shaded Areas Indicate Most Efficient Performance
Metres
2.2
0
5
10
20
30
40
50
60
70
Shut-off
Metres
5
10
15
227
187
150
113
252
206
168
131
94
227
187
150
113
74
5
10
15
20
25
252
206
168
131
95
227
187
150
113
74
20
25
30
35
252
206
168
131
95
252
227
187
150
113
74
30
35
40
45
50
60
80
252
227
206
168
132
95
227
206
187
150
113
74
206
187
168
132
95
169
150
132
95
95
75
40
45
50
60
80
Shut-off 97m
kW
NOTE: Running outside of ‘Recommenced Operating Range’ for short periods of time is permissible.
Actual maximum performance of the SubDrive QuickPAK system is power limited by the SubDrive unit. This limit is based on the
maximum allowable AMP load of the submersible motor. The result is that in some installations an 80 Hz speed may not be attained.
Flow Rate Units = LPM
20
SubDrive
300
SubDrive
SubDrive System
Pressure
Tank
Pressure
Sensor
All in one easy and quick package
to get you pumping quickly.



Pump
Power
Supply

Motor
Model

Order number


SubDrive Pump
SubDrive Motor
SubDrive Controller
Pressure Gauge
Pressure Sensors
Splice Kit
80 Litre Pressure Tank
Also available:
8L to 80L Pressure Tanks
 Electrical Drop Cable
 Bore Accessories
SDQP300-30-400
93801095
SDQP300-45-335
93801595
SDQP300-60-265
93802095
SDQP300-70-240
93802595
SDQP300-100-165
93803595
5 Year Warranty
SDQP300-150-118
93804595
SDQP300-200-82
93806095
SDQP300-270-60
93809095
All SubDrive components:
pump, motor, drive and tank
are covered.
80L Tank
106435106

• All pump ends up to 70 PM feature TriSeal hydraulics
• For river, creek and dam installations, recommend 316SS 4” motors with mechanical seal
with price adder.
• SubDrive 300 enclosure is rated IP55 for outdoor/indoor installation.
For more information go to constantpressure.com
Constant Pressure – SubDrive QuickPAK
SubDrive 300 30 lpm 3 Hp
Curve #: 109154101m
Date: 9/8/09
SDQP300-30-400
550
500
450
Total Head (M)
400
350
300
250
Recommended Operating Range
200
150
100
50
0
5
10
15
20
25
30
35
40
45
Flow (lpm)
22
50
55
60
65
70
75
Constant Pressure – SubDrive QuickPAK
30 LPM – 2m³/h
Depth to Pumping Water Level, or Lift, in Metres Shaded Areas Indicate Most Efficient Performance
kW
Metres
3.7
0
5
10
20
30
40
50
60
70
80
90
100
110
120
130
140
150
160
Shut-off
Metres
5
10
15
20
25
30
67
66
68
67
66
67
66
65
68
67
66
65
67
66
65
64
68
67
66
65
63
5
10
15
20
25
30
35
40
45
50
67
66
65
64
63
68
67
66
65
63
62
67
66
65
64
63
62
68
67
66
65
63
62
61
35
40
45
50
60
80
100 120 140
68
67
66
65
63
62
61
60
58
57
55
54
68
67
66
65
63
62
61
60
58
57
55
54
52
50
68
67
66
65
63
62
61
60
58
57
55
54
52
50
49
47
100
120
140
68
67
66
65
63
62
61
60
68
67
66
65
63
62
61
60
58
57
60
80
Depth to Pumping Water Level, or Lift, in Metres Shaded Areas Indicate Most Efficient Performance
3.7
Metres 160 180 200 220 240 260 280 300 320 340 360 380 400 420 440 460
0
5
10
20
30
40
50
60
70
80
90
100
110
120
130
140
150
160
Shut-off
Metres
67
66
66
65
63
62
61
60
58
57
55
54
52
50
49
47
45
44
65
64
63
62
61
60
58
57
55
54
52
50
49
47
45
44
42
40
62
62
61
60
58
57
55
54
52
50
49
47
45
44
42
40
38
36
60
59
58
57
55
54
52
50
49
47
45
44
42
40
38
36
35
33
57
56
55
54
52
50
49
47
45
44
42
40
38
36
35
33
31
29
54
53
52
50
49
47
45
44
42
40
38
36
35
33
31
29
28
26
50
50
49
47
45
44
42
40
38
36
35
33
31
29
28
26
24
22
47
46
45
44
42
40
38
36
35
33
31
29
28
26
24
22
19
17
44
43
42
40
38
37
35
33
31
29
28
26
24
22
19
17
15
40
39
38
37
35
33
31
29
28
26
24
22
19
17
15
37
36
35
33
31
29
28
26
24
22
19
17
15
33
32
31
29
28
26
24
22
19
17
15
29
29
28
26
24
22
19
17
15
26
25
24
22
20
17
15
22
21
20
17
15
17
16
15
160
180
200
220
240
260
280
300
320
340
360
380
400
420
440
460
Shut-off 512M
kW
NOTE: Running outside of ‘Recommenced Operating Range’ for short periods of time is permissible.
Actual maximum performance of the SubDrive QuickPAK system is power limited by the SubDrive unit. This limit is based on the
maximum allowable AMP load of the submersible motor. The result is that in some installations an 80 Hz speed may not be attained.
Flow Rate Units = LPM
23
Constant Pressure – SubDrive QuickPAK
SubDrive 300 45 lpm 3 Hp
Curve #: 109155101m
Date:9/8/09
SDQP300-45-335
450
400
350
Total Head (M)
300
250
200
Recommended Operating Range
150
100
50
0
10
20
30
40
50
60
Flow (lpm)
24
70
80
90
100
110
Constant Pressure – SubDrive QuickPAK
45 LPM – 3m³/h
Depth to Pumping Water Level, or Lift, in Metres Shaded Areas Indicate Most Efficient Performance
kW
Metres
3.7
0
5
10
20
30
40
50
60
70
80
90
100
110
120
Shut-off
Metres
5
10
15
20
25
30
97
94
93
98
96
93
92
97
94
93
91
98
96
93
92
90
97
94
93
91
89
98
96
93
92
90
88
5
10
15
20
25
30
35
40
45
50
97
94
93
91
89
87
98
96
93
92
90
88
86
97
94
93
91
89
87
86
98
96
93
92
90
88
86
85
35
40
45
50
60
80
100
98
97
96
93
92
90
88
86
85
83
81
78
76
73
100
98
96
93
92
90
88
86
85
83
98
96
93
92
90
88
86
85
83
81
78
60
80
Depth to Pumping Water Level, or Lift, in Metres Shaded Areas Indicate Most Efficient Performance
Metres
3.7
0
5
10
20
30
40
50
60
70
80
90
100
110
120
Shut-off
Metres
120 140 160 180 200 220 240 260 280 300 320 340 360 380
94
93
92
90
88
86
85
83
81
78
76
73
71
68
90
89
88
86
85
83
81
78
76
73
71
68
66
63
86
86
85
83
81
78
76
73
71
68
66
63
60
57
83
82
81
78
76
73
71
68
66
63
60
57
55
52
78
77
76
73
71
68
66
63
60
57
55
52
49
47
73
72
71
68
66
63
60
58
55
52
49
47
44
40
68
67
66
63
60
58
55
52
49
47
44
40
37
33
63
62
60
58
55
52
49
47
44
40
37
33
28
22
58
56
55
52
49
47
44
40
37
33
28
22
52
51
49
47
44
40
37
33
28
22
47
45
44
40
37
33
28
22
40
39
37
33
28
22
33
30
28
22
22
19
120
140
160
180
200
220
240
260
280
300
320
340
360
380
Shut-off 405M
kW
NOTE: Running outside of ‘Recommenced Operating Range’ for short periods of time is permissible.
Actual maximum performance of the SubDrive QuickPAK system is power limited by the SubDrive unit. This limit is based on the
maximum allowable AMP load of the submersible motor. The result is that in some installations an 80 Hz speed may not be attained.
Flow Rate Units = LPM
25
Constant Pressure – SubDrive QuickPAK
SubDrive 300 60 lpm 3 Hp
Curve #: 109156101m
Date: 9/8/09
SDQP300-60-265
350
300
Total Head (M)
250
200
150
Recommended Operating Range
100
50
0
10
20
30
40
50
60
70
80
90 100 110 120 130 140 150
Flow (lpm)
60 LPM – 3.5m³/h
Depth to Pumping Water Level, or Lift, in Metres Shaded Areas Indicate Most Efficient Performance
3.7
0
5
10
20
30
40
50
60
70
80
90
Shut-off
Metres
5
10 15 20 25 30 35 40 45 50 60 80 100 120 140 160 180 200 220 240 260 280
132
130
128
125
122
119
116
112
109
105
100
125
123
122
119
116
112
109
105
100
96
92
119
117
116
112
109
105
100
96
92
87
83
113
111
109
105
100
96
92
87
83
78
73
105
102
100
96
92
87
83
78
73
67
58
96
94
92
87
83
78
73
67
58
47
31
87
85
83
78
73
67
58
47
31
78
76
73
67
58
47
31
67
63
58
47
31
132 130
132 130 128 126
132 130 128 126 125 123
132 130 128 126 124 123 122 120
132
128
125
122
119
132
128
125
122
119
116
132
128
125
122
119
116
112
109
10
50
60
80 100 120 140 160 180 200 220 240 260 280
15
20
25
30
35
40
45
NOTE: Running outside of ‘Recommenced Operating Range’ for short periods of time is permissible.
Actual maximum performance of the SubDrive QuickPAK system is power limited by the SubDrive unit. This limit is based on the
maximum allowable AMP load of the submersible motor. The result is that in some installations an 80 Hz speed may not be attained.
26
47
40
31
Flow Rate Units = LPM
Shut-off 301M
kW Metres 5
Constant Pressure – SubDrive QuickPAK
SubDrive 300 70 lpm 3 Hp
Curve #: 109157101m
Date: 9/8/09
SDQP300-70-240
300
250
Total Head (M)
200
150
Recommended Operating Range
100
50
0
10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160
Flow (lpm)
70 LPM – 4m³/h
Depth to Pumping Water Level, or Lift, in Metres Shaded Areas Indicate Most Efficient Performance
3.7
0
5
10
20
30
40
50
60
70
80
90
Shut-off
Metres
10 15 20 25 30 35 40 45 50 60 80 100 120 140 160 180 200 220 240
151
149 147
145 144
142 141
5
10
149
145
142
140
151
147
144
141
138
149
145
142
140
136
151
147
144
141
138
135
15
20
25
30
149
145
142
140
136
133
151
147
144
141
138
135
131
149
145
142
140
136
133
129
151
147
144
141
138
135
131
127
35
40
45
50
151
147
144
141
138
135
131
127
122
147
145
144
141
138
135
131
127
122
117
112
141
140
138
135
131
127
122
117
112
107
102
135
133
131
127
122
117
112
107
102
97
92
127
124
122
117
112
107
102
97
92
86
79
117
115
112
107
102
97
92
86
79
69
56
107
105
102
97
92
86
79
69
56
97
95
92
86
79
69
56
86
83
79
70
56
70
63
56
60
80 100 120 140 160 180 200 220 240
Shut-off 258M
kW Metres 5
NOTE: Running outside of ‘Recommenced Operating Range’ for short periods of time is permissible.
Actual maximum performance of the SubDrive QuickPAK system is power limited by the SubDrive unit. This limit is based on the
maximum allowable AMP load of the submersible motor. The result is that in some installations an 80 Hz speed may not be attained.
Flow Rate Units = LPM
27
Constant Pressure – SubDrive QuickPAK
SubDrive 300 100 lpm 3 Hp
Curve #: 109158101m
Date: 9/8/09
SDQP300-100-165
220
200
180
Total Head (M)
160
140
120
100
Recommended Operating Range
80
60
40
20
0
50
100
150
200
250
Flow (lpm)
100 LPM – 6m³/h
kW
Metres
3.7
0
5
10
20
30
40
50
60
70
Shut-off
Metres
5
10
15
224
214
205
219
209
201
224
214
205
197
5
10
15
20
25
30
35
219
209
201
193
224
214
205
197
188
219
209
201
193
183
224
214
205
197
188
178
20
25
30
35
40
45
50
60
80
100 120 140 160 180
219
214
209
201
193
183
172
160
148
201
197
193
183
172
160
148
135
123
183
178
172
160
148
135
123
110
96
160
154
148
135
123
110
96
79
57
135
129
123
110
96
79
57
110
104
96
79
57
80
69
57
60
80
100
120
140
160
180
219
209
201
193
183
172
224
214
205
197
188
178
166
224
219
209
201
193
183
172
160
40
45
50
NOTE: Running outside of ‘Recommenced Operating Range’ for short periods of time is permissible.
Actual maximum performance of the SubDrive QuickPAK system is power limited by the SubDrive unit. This limit is based on the
maximum allowable AMP load of the submersible motor. The result is that in some installations an 80 Hz speed may not be attained.
Flow Rate Units = LPM
28
Shut-off 205M
Depth to Pumping Water Level, or Lift, in Metres Shaded Areas Indicate Most Efficient Performance
Constant Pressure – SubDrive QuickPAK
SubDrive 300 150 lpm 3 Hp
Curve #: 109159101m
Date: 9/9/09
SDQP300-150-118
180
160
140
Total Head (M)
120
100
80
Recommended Operating Range
60
40
20
0
50
100
150
200
250
300
Flow (lpm)
150 LPM – 9m³/h
kW
Metres
3.7
0
5
10
20
30
40
50
60
70
Shut-off
Metres
5
10
15
20
25
30
263
248
232
271
256
240
223
263
248
232
215
271
256
240
224
206
263
248
232
215
196
271
256
240
224
206
187
5
10
15
20
25
30
35
40
45
50
60
80
100 120 140 160
271
263
256
240
224
206
187
166
144
256
248
240
224
206
187
166
144
120
224
215
206
187
166
144
120
94
67
187
177
166
144
120
94
67
39
11
144
132
120
94
67
39
11
94
81
67
39
11
39
25
11
50
60
80
100
120
140
160
263
248
232
215
196
176
271
256
240
224
206
187
166
271
263
248
232
215
196
176
155
35
40
45
Shut-off 174M
Depth to Pumping Water Level, or Lift, in Metres Shaded Areas Indicate Most Efficient Performance
NOTE: Running outside of ‘Recommenced Operating Range’ for short periods of time is permissible.
Actual maximum performance of the SubDrive QuickPAK system is power limited by the SubDrive unit. This limit is based on the
maximum allowable AMP load of the submersible motor. The result is that in some installations an 80 Hz speed may not be attained.
Flow Rate Units = LPM
29
Constant Pressure – SubDrive QuickPAK
SubDrive 300 200 lpm 3 Hp
Curve #: 109160101m
Date: 9/9/09
SDQP300-200-82
140
130
120
110
Total Head (M)
100
90
80
70
60
50
Recommended Operating Range
40
30
20
10
0
50
100
150
200
250
300
350
400
Flow (lpm)
200 LPM – 12m³/h
kW
Metres
3.7
0
5
10
20
30
40
50
60
70
Shut-off
Metres
5
10
15
357
328
296
260
223
343
312
279
242
204
357
328
296
260
223
185
5
10
15
20
25
30
35
40
45
50
60
80
100
357
343
328
296
261
223
185
150
117
343
328
312
279
242
204
168
133
328
312
296
261
223
186
150
117
312
296
279
242
204
168
134
279
261
242
204
168
134
204
186
168
134
134
117
35
40
45
50
60
80
100
343
312
279
242
204
167
357
328
296
261
223
185
150
357
343
312
279
242
204
168
133
20
25
30
Shut-off 129M
Depth to Pumping Water Level, or Lift, in Metres Shaded Areas Indicate Most Efficient Performance
NOTE: Running outside of ‘Recommenced Operating Range’ for short periods of time is permissible.
Actual maximum performance of the SubDrive QuickPAK system is power limited by the SubDrive unit. This limit is based on the
maximum allowable AMP load of the submersible motor. The result is that in some installations an 80 Hz speed may not be attained.
Flow Rate Units = LPM
30
Constant Pressure – SubDrive QuickPAK
SubDrive 300 270 lpm 3 Hp
Curve #: 109161101m
Date: 9/9/09
SDQP300-270-60
90
80
70
Total Head (M)
60
50
40
Recommended Operating Range
30
20
10
0
50
100
150
200
250
300
350
400
450
500
550
600
Flow (lpm)
270 LPM – 16m³/h
kW
Metres
3.7
0
5
10
20
30
40
50
60
70
Shut-off
Metres
5
10
558
481
392
302
224
522
438
346
262
185
5
10
15
20
558
482
392
303
224
558
522
438
346
262
185
15
20
25
30
35
40
45
50
60
558
522
482
392
303
224
522
482
438
346
262
185
482
438
392
303
224
438
392
346
262
185
392
347
303
224
347
303
262
186
262
224
186
25
30
35
40
45
50
60
Shut-off 83m
Depth to Pumping Water Level, or Lift, in Metres Shaded Areas Indicate Most Efficient Performance
NOTE: Running outside of ‘Recommenced Operating Range’ for short periods of time is permissible.
Actual maximum performance of the SubDrive QuickPAK system is power limited by the SubDrive unit. This limit is based on the
maximum allowable AMP load of the submersible motor. The result is that in some installations an 80 Hz speed may not be attained.
Flow Rate Units = LPM
31
AUSTRALIA / NEW ZEALAND
Franklin Electric (Australia) Pty. Ltd.
106-110 Micro Circuit
Dandenong South, Victoria 3175
Australia
Toll Free: 1
300 FRANKLIN
1300 372 655
Fax: +61 3 9799 5050
Tel: +61 3 9799 5000
www.franklin-electric.com.au
United States
Franklin Electric Co., Inc.
400 E. Spring Street, Bluffton, IN 46714 USA
Tel: +1.260.824.2900 Fax: +1.260.824.2909
FE781 03/12
Download