QuickPAK now available for SubDrive 75, 150 & 300 What is SubDrive SubDrive is Franklin Electric’s variable frequency drive constant pressure system. SubDrive QuickPAK comprises of a Pump, Motor, Drive, Pressure tank and Sensor all in one quick and easy package. SubDrive controllers provide constant pressure by continually monitoring and adjusting the pump speed to meet water demands. SubDrive also eliminates pressure fluctuations during long running applications such as reticulation/irrigation systems and other domestic and industrial uses. Applications Residential Water Systems • City-like water pressure • Compact design saves space in garages and sheds L andscape Irrigation and Sprinkler Systems • Even distribution of water in zones • Eliminates need for separate system Features and benefits Constant water pressure with a wide range of settings Soft start feature eliminates water hammer and increases motor life Works with small pressure tanks or with larger tanks already in place Water Treatment Systems • More efficient back-flushing • Eliminates need for multiple pumps S mart Reset® technology allows well recovery before restarting the pump S ingle-phase input power with three-phase motor performance Geothermal Heating Systems E xcellent radio frequency interference shielding W ide operating voltage (190-260V) Built-in Diagnostics and Protection The SubDrive controller include diagnostic features and built-in protection for conditions that would be harmful to the system. This protection includes: Surge protection Underload Undervoltage Locked pump Open circuit Short circuit Overheated controller 75 5 5 W A RR Pressure Tank * AN T SubDrive SubDrive System Pressure Sensor All in one easy and quick package to get you pumping quickly. Pump Power Supply Motor Model YEAR Y SubDrive Order number SDQP75-25-160 93800705 SDQP75-30-135 93801005 SDQP75-45-105 93801505 SDQP75-60-83 93802005 SDQP75-70-82 93802505 SDQP75-100-55 93803505 18L Tank 106435103 SubDrive Pump SubDrive Motor SubDrive Controller Pressure Gauge Pressure Sensor Splice Kit 18 Litre Pressure Tank Also available: 8L to 80L Pressure Tanks Electrical Drop Cable Bore Accessories * 5 Year Warranty All SubDrive components: pump, motor, drive and tank are covered. • All pump ends up to 70 PM feature TriSeal hydraulics • For river, creek and dam installations, recommend 316SS 4” motors with mechanical seal with price adder. • SubDrive 75 enclosure is rated IP20 for indoor installation. Outdoor enclosure rated IP55 available with price adder. For more information go to constantpressure.com Constant Pressure – SubDrive QuickPAK SubDrive 75 25 lpm .75 Hp Curve #: 109099101m Date: 3/2/10 SDQP75-25-160 250 Total Head (M) 200 150 100 Recommended Operating Range 50 0 5 10 15 20 25 30 35 40 45 50 55 Flow (lpm) 25 LPM – 1.5m³/h Depth to Pumping Water Level, or Lift, in Metres Shaded Areas Indicate Most Efficient Performance Metres 1.1 0 5 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 Shut-off Metres 5 10 15 49 48 46 44 42 40 37 35 32 29 26 23 19 16 12 49 47 45 43 41 39 36 34 31 28 25 21 18 14 49 48 46 44 42 40 37 35 32 29 26 23 19 16 12 223 218 213 20 25 30 35 49 47 45 43 41 39 36 34 31 28 25 21 18 14 49 48 46 44 42 40 37 35 32 29 26 23 19 16 12 49 47 45 43 41 39 36 34 31 28 25 21 18 14 49 48 46 44 42 40 37 35 32 29 26 23 19 16 12 208 203 198 193 40 49 47 45 43 41 39 36 34 31 28 25 21 18 14 10 188 45 49 48 46 44 42 40 37 35 32 29 26 23 19 16 12 183 50 49 49 47 45 43 41 39 36 34 31 28 25 21 18 14 178 60 80 100 120 140 160 180 49 48 47 45 43 41 39 36 34 31 28 25 21 18 14 45 44 43 41 39 36 34 31 28 25 21 18 14 41 40 39 36 34 31 28 25 21 18 14 36 35 34 31 28 25 21 18 14 31 29 28 25 21 18 14 25 23 21 18 14 18 16 14 168 148 128 108 88 68 48 Shut Off Head 228 metres Motor kW NOTE: Running outside of ‘Recommenced Operating Range’ for short periods of time is permissible. Actual maximum performance of the SubDrive QuickPAK system is power limited by the SubDrive unit. This limit is based on the maximum allowable AMP load of the submersible motor. The result is that in some installations an 80 Hz speed may not be attained. Flow Rate Units = LPM 4 Constant Pressure – SubDrive QuickPAK SubDrive 75 30 lpm .75 HP Curve #: 109100101m Date: 3/2/10 Total Head (M) SDQP75-30-135 180 170 160 150 140 130 120 110 100 90 80 70 60 50 40 30 20 10 0 Recommended Operating Range 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 Flow (lpm) 30 LPM – 2m³/h Depth to Pumping Water Level, or Lift, in Metres Shaded Areas Indicate Most Efficient Performance Metres 1.1 0 5 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 Shut-off Metres 5 63 59 56 52 48 44 39 34 29 24 18 173 10 15 64 61 57 54 50 46 41 37 32 27 21 63 59 56 52 48 44 39 34 29 24 18 168 163 20 25 64 61 57 54 50 46 41 37 32 27 21 63 59 56 52 48 44 39 34 29 24 18 158 153 30 35 64 61 57 54 50 46 41 37 32 27 21 63 59 56 52 48 44 39 34 29 24 18 148 143 40 45 64 61 57 54 50 46 41 37 32 27 21 64 63 59 56 52 48 44 39 34 29 24 18 138 133 50 60 80 100 120 140 64 63 61 57 54 50 46 41 37 32 27 21 61 59 57 54 50 46 41 37 32 27 21 54 52 50 46 41 37 32 27 21 46 44 41 37 32 27 21 37 35 32 27 21 27 24 21 128 118 98 78 58 38 Shut Off Head 177.5 metres Motor kW NOTE: Running outside of ‘Recommenced Operating Range’ for short periods of time is permissible. Actual maximum performance of the SubDrive QuickPAK system is power limited by the SubDrive unit. This limit is based on the maximum allowable AMP load of the submersible motor. The result is that in some installations an 80 Hz speed may not be attained. Flow Rate Units = LPM 5 Constant Pressure – SubDrive QuickPAK SubDrive 75 45 lpm .75 Hp Curve #: 109101101m Date:3/2/10 SDQP75-45-105 150 140 130 120 110 Total Head (M) 100 90 80 70 60 Recommended Operating Range 50 40 30 20 10 0 10 20 30 40 50 60 70 80 90 100 110 Flow (lpm) 45 LPM – 3m³/h Depth to Pumping Water Level, or Lift, in Metres Shaded Areas Indicate Most Efficient Performance Metres 1.1 0 5 10 20 30 40 50 60 70 80 90 100 110 120 Shut-off Metres 5 10 92 86 79 71 63 54 45 33 89 82 75 67 59 50 39 26 128 123 15 20 92 86 79 71 63 54 45 33 89 82 75 67 59 50 39 26 118 113 25 30 92 86 79 71 63 54 45 33 89 82 75 67 59 50 39 26 108 103 35 40 92 86 79 71 63 54 45 33 92 89 82 75 67 59 50 39 26 98 93 45 50 60 80 100 120 92 89 86 79 71 63 54 45 33 89 86 82 75 67 59 50 39 26 82 79 75 67 59 50 39 26 67 63 59 50 39 26 50 45 39 26 26 88 83 73 53 33 13 Shut Off Head 133 metres kW NOTE: Running outside of ‘Recommenced Operating Range’ for short periods of time is permissible. Actual maximum performance of the SubDrive QuickPAK system is power limited by the SubDrive unit. This limit is based on the maximum allowable AMP load of the submersible motor. The result is that in some installations an 80 Hz speed may not be attained. Flow Rate Units = LPM 6 Constant Pressure – SubDrive QuickPAK SubDrive 75 60 lpm .75 Hp Curve #: 109164101m Date: 3/2/10 SDQP75-60-83 100 90 80 Total Head (M) 70 60 50 Recommended Operating Range 40 30 20 10 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 Flow (lpm) 60 LPM – 3.5m³/h kW Metres 1.1 0 5 10 20 30 40 50 60 70 80 90 Shut-off Metres 5 10 128 119 107 92 76 58 123 114 100 84 68 42 91 86 15 20 128 119 107 92 76 58 123 114 100 84 68 42 81 76 25 30 128 119 107 92 76 58 128 123 114 100 84 68 42 71 66 35 40 45 50 60 80 128 123 119 107 92 76 58 123 119 114 100 84 68 42 119 114 107 92 76 58 114 107 100 84 68 42 100 92 84 68 42 68 58 42 61 56 51 46 36 16 Shut Off Head 95.85 metres Depth to Pumping Water Level, or Lift, in Metres Shaded Areas Indicate Most Efficient Performance NOTE: Running outside of ‘Recommenced Operating Range’ for short periods of time is permissible. Actual maximum performance of the SubDrive QuickPAK system is power limited by the SubDrive unit. This limit is based on the maximum allowable AMP load of the submersible motor. The result is that in some installations an 80 Hz speed may not be attained. Flow Rate Units = LPM 7 Constant Pressure – SubDrive QuickPAK SubDrive 75 70 lpm .75 Hp Curve #: 109103101m Date: 1/19/10 SDQP75-70-82 110 100 90 Total Head (M) 80 70 60 50 Recommended Operating Range 40 30 20 10 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 Flow (lpm) 70 LPM – 4m³/h kW Metres 1.1 0 5 10 20 30 40 50 60 70 80 90 Shut-off Metres 5 10 15 148 136 128 115 99 82 63 141 132 122 107 90 73 148 136 128 115 99 82 63 96 91 86 20 25 30 35 40 45 50 60 80 148 141 132 122 107 90 73 148 141 136 128 115 99 82 64 141 136 132 122 107 90 73 136 132 128 115 99 82 64 132 128 122 107 90 73 128 122 115 99 82 64 122 115 107 90 73 107 99 90 73 73 64 81 76 71 66 61 56 51 41 21 Shut Off Head 101 metres Depth to Pumping Water Level, or Lift, in Metres Shaded Areas Indicate Most Efficient Performance NOTE: Running outside of ‘Recommenced Operating Range’ for short periods of time is permissible. Actual maximum performance of the SubDrive QuickPAK system is power limited by the SubDrive unit. This limit is based on the maximum allowable AMP load of the submersible motor. The result is that in some installations an 80 Hz speed may not be attained. Flow Rate Units = LPM 8 Constant Pressure – SubDrive QuickPAK SubDrive 75 100-55 Curve #: 108377101-3m Date: 10/16/08 SDQP75-100-55 80 70 Total Head (M) 60 50 40 30 Recommended Operating Range 20 10 0 50 100 150 200 250 Flow (lpm) 100 LPM – 6m³/h kW Metres 1.1 0 5 10 20 30 40 50 60 70 Shut-off Metres 5 227 183 154 125 97 68 72 10 15 20 25 30 35 40 45 50 60 227 201 168 140 110 83 227 201 183 154 125 97 68 201 183 168 140 111 83 183 168 154 125 97 69 168 154 140 111 83 154 140 125 97 69 140 125 111 83 125 111 97 69 111 97 83 83 69 67 62 57 52 47 42 37 32 27 17 Shut Off Head 77.0 metres Depth to Pumping Water Level, or Lift, in Metres Shaded Areas Indicate Most Efficient Performance NOTE: Running outside of ‘Recommenced Operating Range’ for short periods of time is permissible. Actual maximum performance of the SubDrive QuickPAK system is power limited by the SubDrive unit. This limit is based on the maximum allowable AMP load of the submersible motor. The result is that in some installations an 80 Hz speed may not be attained. Flow Rate Units = LPM 9 Constant Pressure – SubDrive QuickPAK Notes SubDrive 150 SubDrive SubDrive System Pressure Tank Pressure Sensor All in one easy and quick package to get you pumping quickly. Pump Power Supply Motor Model Order number SDQP150-25-300 93800790 SDQP150-30-245 93801090 SDQP150-45-195 93801590 SDQP150-60-155 93802090 SDQP150-65-137 93802590 SDQP150-100-94 93803590 SDQP150-150-65 93804590 35L Tank 106435104 SubDrive Pump SubDrive Motor SubDrive Controller Pressure Gauge Pressure Sensor Splice Kit 35 Litre Pressure Tank Also available: 8L to 80L Pressure Tanks Electrical Drop Cable Bore Accessories 5 Year Warranty All SubDrive components: pump, motor, drive and tank are covered. • All pump ends up to 70 PM feature TriSeal hydraulics • For river, creek and dam installations, recommend 316SS 4” motors with mechanical seal with price adder. • SubDrive 150 enclosure is rated IP55 for outdoor/indoor installation. For more information go to constantpressure.com Constant Pressure – SubDrive QuickPAK SubDrive 150 1.5 Hp 25 lpm Curve #: 109113101m Date: 9/8/09 SDQP150-25-300 450 400 350 Total Head (M) 300 250 200 Recommended Operating Range 150 100 50 0 5 10 15 20 25 30 Flow (lpm) 12 35 40 45 50 55 Constant Pressure – SubDrive QuickPAK Constant Pressure – SubDrive QuickPAK 25 LPM – 1m³/h Depth to Pumping Water Level, or Lift, in Metres Shaded Areas Indicate Most Efficient Performance kW Metres 2.2 0 5 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 Shut-off Metres 5 10 15 20 25 49 48 47 46 45 44 43 42 41 40 39 48 47 46 45 44 43 42 41 40 39 38 49 48 47 46 45 44 43 42 41 40 39 38 48 47 46 45 44 43 42 41 40 39 38 37 49 48 47 46 45 44 43 42 41 40 39 38 36 5 10 15 20 25 30 35 40 45 48 47 46 45 44 43 42 41 40 39 38 37 36 49 48 47 46 45 44 43 42 41 40 39 38 36 35 48 47 46 45 44 43 42 41 40 39 38 37 36 34 49 48 47 46 45 44 43 42 41 40 39 38 36 35 34 30 35 40 45 50 60 80 100 48 48 47 46 45 44 43 42 41 40 39 38 37 36 35 33 32 31 29 28 26 100 48 47 46 45 44 43 42 41 40 39 38 37 36 34 33 48 47 46 45 44 43 42 41 40 39 38 37 36 35 33 32 48 47 46 45 44 43 42 41 40 39 38 37 36 35 33 32 31 29 50 60 80 Depth to Pumping Water Level, or Lift, in Metres Shaded Areas Indicate Most Efficient Performance Metres 2.2 0 5 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 Shut-off Metres 120 140 160 180 200 220 240 260 280 300 320 340 360 380 46 46 45 44 43 42 41 40 39 38 37 36 35 33 32 31 29 28 27 25 24 44 44 43 42 41 40 39 38 37 36 35 33 32 31 29 28 27 25 24 22 20 42 42 41 40 39 38 37 36 35 33 32 31 29 28 27 25 24 22 20 19 17 40 40 39 38 37 36 35 33 32 31 29 28 27 25 24 22 20 19 17 15 13 38 38 37 36 35 33 32 31 29 28 27 25 24 22 20 19 17 15 13 10 36 35 35 33 32 31 29 28 27 25 24 22 20 19 17 15 13 11 33 33 32 31 29 28 27 25 24 22 20 19 17 15 13 11 31 30 29 28 27 25 24 22 20 19 17 15 13 11 28 27 27 25 24 22 20 19 17 15 13 11 25 24 24 22 20 19 17 15 13 11 22 21 20 19 17 15 13 11 19 18 17 15 13 11 15 14 13 11 11 9 120 140 160 180 200 220 240 260 280 300 320 340 360 380 Shut-off 417m kW NOTE: Running outside of ‘Recommenced Operating Range’ for short periods of time is permissible. Actual maximum performance of the SubDrive QuickPAK system is power limited by the SubDrive unit. This limit is based on the maximum allowable AMP load of the submersible motor. The result is that in some installations an 80 Hz speed may not be attained. Flow Rate Units = LPM 13 Constant Pressure – SubDrive QuickPAK SubDrive 150 30 lpm 1.5 Hp Curve #: 109151101m Date: 9/8/09 SDQP150-30-245 350 300 Total Head (M) 250 200 150 Recommended Operating Range 100 50 0 5 10 15 20 25 30 35 40 45 Flow (lpm) 14 50 55 60 65 70 75 Constant Pressure – SubDrive QuickPAK 30 LPM – 2m³/h Depth to Pumping Water Level, or Lift, in Metres Shaded Areas Indicate Most Efficient Performance kW Metres 2.2 0 5 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 Shut-off Metres 5 10 15 20 25 68 66 65 63 62 60 58 56 54 52 67 66 64 63 61 59 57 55 53 51 68 66 65 63 62 60 58 56 54 52 50 67 66 64 63 61 59 57 55 53 51 49 68 66 65 63 62 60 58 56 54 52 50 48 5 10 15 20 25 30 35 40 45 50 60 67 66 64 63 61 59 57 55 53 51 49 46 44 41 67 66 64 63 61 59 57 55 53 51 49 46 44 41 38 50 60 67 66 64 63 61 59 57 55 53 51 49 46 68 66 65 63 62 60 58 56 54 52 50 48 45 67 66 64 63 61 59 57 55 53 51 49 46 44 68 66 65 63 62 60 58 56 54 52 50 48 45 42 30 35 40 45 Depth to Pumping Water Level, or Lift, in Metres Shaded Areas Indicate Most Efficient Performance Metres 80 100 120 140 160 180 200 220 240 260 280 67 66 66 64 63 61 59 57 55 53 51 49 46 44 41 38 35 32 64 63 63 61 59 57 55 53 51 49 46 44 41 38 35 32 28 25 61 60 59 57 55 53 51 49 46 44 41 38 35 32 28 25 21 18 57 56 55 53 51 49 46 44 41 38 35 32 28 25 21 18 53 52 51 49 46 44 41 38 35 32 28 25 21 18 49 48 46 44 41 38 35 32 28 25 21 18 44 42 41 38 35 32 28 25 21 18 38 36 35 32 28 25 21 18 32 30 28 25 21 18 25 23 21 18 18 16 2.2 0 5 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 80 100 120 140 160 180 200 220 240 260 280 Shut-off Metres Shut-off 338m kW NOTE: Running outside of ‘Recommenced Operating Range’ for short periods of time is permissible. Actual maximum performance of the SubDrive QuickPAK system is power limited by the SubDrive unit. This limit is based on the maximum allowable AMP load of the submersible motor. The result is that in some installations an 80 Hz speed may not be attained. Flow Rate Units = LPM 15 Constant Pressure – SubDrive QuickPAK SubDrive 150 45 lpm 1.5 Hp Curve #: 109115101m Date:9/8/09 SDQP150-45-195 250 Total Head (M) 200 150 100 Recommended Operating Range 50 0 10 20 30 40 50 60 70 80 90 100 110 Flow (lpm) 45 LPM – 3m³/h Depth to Pumping Water Level, or Lift, in Metres Shaded Areas Indicate Most Efficient Performance Metres 2.2 0 5 10 20 30 40 50 60 70 80 90 100 110 120 Shut-off Metres 5 10 15 97 94 91 88 84 81 77 96 92 89 86 83 79 75 97 94 91 88 84 81 77 73 5 10 15 20 25 30 35 96 92 89 86 83 79 75 71 97 94 91 88 84 81 77 73 69 96 92 89 86 83 79 75 71 67 97 94 91 88 84 81 77 73 69 64 20 25 30 35 40 45 50 60 80 100 120 140 160 180 200 220 92 91 89 86 83 79 75 71 67 62 58 53 48 42 86 84 83 79 75 71 67 62 58 53 48 42 36 29 80 100 120 140 160 180 200 220 96 92 89 86 83 79 75 71 67 62 97 94 91 88 84 81 77 73 69 64 60 96 92 89 86 83 79 75 71 67 62 58 97 96 92 89 86 83 79 75 71 67 62 58 53 40 45 50 60 79 77 75 71 67 62 58 53 48 42 36 29 21 71 69 67 62 58 53 48 42 36 29 21 62 60 58 53 48 42 36 29 21 53 50 48 42 36 29 21 42 39 36 29 21 NOTE: Running outside of ‘Recommenced Operating Range’ for short periods of time is permissible. Actual maximum performance of the SubDrive QuickPAK system is power limited by the SubDrive unit. This limit is based on the maximum allowable AMP load of the submersible motor. The result is that in some installations an 80 Hz speed may not be attained. Flow Rate Units = LPM 16 29 25 21 Shut-off 248m kW Constant Pressure – SubDrive QuickPAK SubDrive 150 60 lpm 1.5 Hp Curve #: 109153101m Date: 9/8/09 Total Head (M) SDQP150-60-155 180 170 160 150 140 130 120 110 100 90 80 70 60 50 40 30 20 10 0 Recommended Operating Range 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 Flow (lpm) 60 LPM – 3.5m³/h kW Metres 2.2 0 5 10 20 30 40 50 60 70 80 90 Shut-off Metres 5 10 15 132 125 120 114 128 122 117 110 132 125 120 114 106 5 10 15 20 25 30 35 128 122 117 110 102 132 125 120 114 106 98 128 122 117 110 102 94 132 125 120 114 106 98 90 20 25 30 35 40 45 50 60 80 100 120 140 160 123 110 120 107 117 103 110 94 103 85 94 76 85 66 76 53 66 32 53 32 128 122 117 110 102 94 85 132 125 120 114 106 98 90 81 128 122 117 110 103 94 85 76 132 128 122 117 110 103 94 85 76 66 40 45 50 60 80 94 90 85 76 66 53 32 76 71 66 53 32 53 44 32 Shut-off 177m Depth to Pumping Water Level, or Lift, in Metres Shaded Areas Indicate Most Efficient Performance 100 120 140 160 NOTE: Running outside of ‘Recommenced Operating Range’ for short periods of time is permissible. Actual maximum performance of the SubDrive QuickPAK system is power limited by the SubDrive unit. This limit is based on the maximum allowable AMP load of the submersible motor. The result is that in some installations an 80 Hz speed may not be attained. Flow Rate Units = LPM 17 Constant Pressure – SubDrive QuickPAK SubDrive 150 70 lpm 1.5 Hp Curve #: 109117101m Date: 9/8/09 SDQP150-65-137 160 150 140 130 120 110 Total Head (M) 100 90 80 70 Recommended Operating Range 60 50 40 30 20 10 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 Flow (lpm) 70 LPM – 4m³/h kW Metres 2.2 0 5 10 20 30 40 50 60 70 80 90 5 10 15 149 140 132 122 144 136 127 116 149 140 132 122 110 5 10 15 Shut-off Metres 20 25 30 35 144 136 127 116 104 149 140 132 122 110 98 144 136 127 116 104 92 149 140 132 122 110 98 87 20 25 30 35 40 45 50 60 144 136 127 116 104 92 81 149 140 132 122 110 98 87 74 144 136 127 116 104 92 81 66 149 144 136 127 116 104 93 81 66 38 40 45 50 60 80 100 120 140 136 132 127 117 104 93 81 66 39 117 111 104 93 81 66 39 93 87 81 66 39 66 55 39 80 100 120 140 NOTE: Running outside of ‘Recommenced Operating Range’ for short periods of time is permissible. Actual maximum performance of the SubDrive QuickPAK system is power limited by the SubDrive unit. This limit is based on the maximum allowable AMP load of the submersible motor. The result is that in some installations an 80 Hz speed may not be attained. 18 Flow Rate Units = LPM Shut-off 152m Depth to Pumping Water Level, or Lift, in Metres Shaded Areas Indicate Most Efficient Performance Constant Pressure – SubDrive QuickPAK SubDrive 150 100 lpm 1.5 Hp Curve #: 109118101m Date: 9/8/09 SDQP150-100-94 120 110 100 90 Total Head (M) 80 70 60 50 Recommended Operating Range 40 30 20 10 0 50 100 150 200 250 Flow (lpm) 100 LPM – 6m³/h kW Metres 2.2 0 5 10 20 30 40 50 60 70 Shut-off Metres 5 10 15 20 25 30 35 40 45 50 60 80 100 224 217 208 191 169 144 123 224 220 217 208 191 169 144 123 105 220 217 213 200 180 157 133 114 98 217 213 208 191 169 144 123 105 89 213 208 200 181 157 133 114 98 78 208 200 191 169 145 123 105 89 63 200 191 181 157 133 114 98 78 191 181 169 145 123 105 89 63 169 157 145 123 105 89 63 123 114 106 89 63 89 79 63 220 213 200 180 156 133 224 220 213 200 180 156 133 114 5 10 15 20 25 30 35 40 45 50 60 80 100 Shut-off 118m Depth to Pumping Water Level, or Lift, in Metres Shaded Areas Indicate Most Efficient Performance NOTE: Running outside of ‘Recommenced Operating Range’ for short periods of time is permissible. Actual maximum performance of the SubDrive QuickPAK system is power limited by the SubDrive unit. This limit is based on the maximum allowable AMP load of the submersible motor. The result is that in some installations an 80 Hz speed may not be attained. Flow Rate Units = LPM 19 Constant Pressure – SubDrive QuickPAK SubDrive 150 150 lpm 1.5 Hp Curve #: 109119101m Date: 9/9/09 SDQP150-150-65 100 90 80 Total Head (M) 70 60 50 Recommended Operating Range 40 30 20 10 0 50 100 150 200 250 300 Flow (lpm) 150 LPM – 9m³/h Depth to Pumping Water Level, or Lift, in Metres Shaded Areas Indicate Most Efficient Performance Metres 2.2 0 5 10 20 30 40 50 60 70 Shut-off Metres 5 10 15 227 187 150 113 252 206 168 131 94 227 187 150 113 74 5 10 15 20 25 252 206 168 131 95 227 187 150 113 74 20 25 30 35 252 206 168 131 95 252 227 187 150 113 74 30 35 40 45 50 60 80 252 227 206 168 132 95 227 206 187 150 113 74 206 187 168 132 95 169 150 132 95 95 75 40 45 50 60 80 Shut-off 97m kW NOTE: Running outside of ‘Recommenced Operating Range’ for short periods of time is permissible. Actual maximum performance of the SubDrive QuickPAK system is power limited by the SubDrive unit. This limit is based on the maximum allowable AMP load of the submersible motor. The result is that in some installations an 80 Hz speed may not be attained. Flow Rate Units = LPM 20 SubDrive 300 SubDrive SubDrive System Pressure Tank Pressure Sensor All in one easy and quick package to get you pumping quickly. Pump Power Supply Motor Model Order number SubDrive Pump SubDrive Motor SubDrive Controller Pressure Gauge Pressure Sensors Splice Kit 80 Litre Pressure Tank Also available: 8L to 80L Pressure Tanks Electrical Drop Cable Bore Accessories SDQP300-30-400 93801095 SDQP300-45-335 93801595 SDQP300-60-265 93802095 SDQP300-70-240 93802595 SDQP300-100-165 93803595 5 Year Warranty SDQP300-150-118 93804595 SDQP300-200-82 93806095 SDQP300-270-60 93809095 All SubDrive components: pump, motor, drive and tank are covered. 80L Tank 106435106 • All pump ends up to 70 PM feature TriSeal hydraulics • For river, creek and dam installations, recommend 316SS 4” motors with mechanical seal with price adder. • SubDrive 300 enclosure is rated IP55 for outdoor/indoor installation. For more information go to constantpressure.com Constant Pressure – SubDrive QuickPAK SubDrive 300 30 lpm 3 Hp Curve #: 109154101m Date: 9/8/09 SDQP300-30-400 550 500 450 Total Head (M) 400 350 300 250 Recommended Operating Range 200 150 100 50 0 5 10 15 20 25 30 35 40 45 Flow (lpm) 22 50 55 60 65 70 75 Constant Pressure – SubDrive QuickPAK 30 LPM – 2m³/h Depth to Pumping Water Level, or Lift, in Metres Shaded Areas Indicate Most Efficient Performance kW Metres 3.7 0 5 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 Shut-off Metres 5 10 15 20 25 30 67 66 68 67 66 67 66 65 68 67 66 65 67 66 65 64 68 67 66 65 63 5 10 15 20 25 30 35 40 45 50 67 66 65 64 63 68 67 66 65 63 62 67 66 65 64 63 62 68 67 66 65 63 62 61 35 40 45 50 60 80 100 120 140 68 67 66 65 63 62 61 60 58 57 55 54 68 67 66 65 63 62 61 60 58 57 55 54 52 50 68 67 66 65 63 62 61 60 58 57 55 54 52 50 49 47 100 120 140 68 67 66 65 63 62 61 60 68 67 66 65 63 62 61 60 58 57 60 80 Depth to Pumping Water Level, or Lift, in Metres Shaded Areas Indicate Most Efficient Performance 3.7 Metres 160 180 200 220 240 260 280 300 320 340 360 380 400 420 440 460 0 5 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 Shut-off Metres 67 66 66 65 63 62 61 60 58 57 55 54 52 50 49 47 45 44 65 64 63 62 61 60 58 57 55 54 52 50 49 47 45 44 42 40 62 62 61 60 58 57 55 54 52 50 49 47 45 44 42 40 38 36 60 59 58 57 55 54 52 50 49 47 45 44 42 40 38 36 35 33 57 56 55 54 52 50 49 47 45 44 42 40 38 36 35 33 31 29 54 53 52 50 49 47 45 44 42 40 38 36 35 33 31 29 28 26 50 50 49 47 45 44 42 40 38 36 35 33 31 29 28 26 24 22 47 46 45 44 42 40 38 36 35 33 31 29 28 26 24 22 19 17 44 43 42 40 38 37 35 33 31 29 28 26 24 22 19 17 15 40 39 38 37 35 33 31 29 28 26 24 22 19 17 15 37 36 35 33 31 29 28 26 24 22 19 17 15 33 32 31 29 28 26 24 22 19 17 15 29 29 28 26 24 22 19 17 15 26 25 24 22 20 17 15 22 21 20 17 15 17 16 15 160 180 200 220 240 260 280 300 320 340 360 380 400 420 440 460 Shut-off 512M kW NOTE: Running outside of ‘Recommenced Operating Range’ for short periods of time is permissible. Actual maximum performance of the SubDrive QuickPAK system is power limited by the SubDrive unit. This limit is based on the maximum allowable AMP load of the submersible motor. The result is that in some installations an 80 Hz speed may not be attained. Flow Rate Units = LPM 23 Constant Pressure – SubDrive QuickPAK SubDrive 300 45 lpm 3 Hp Curve #: 109155101m Date:9/8/09 SDQP300-45-335 450 400 350 Total Head (M) 300 250 200 Recommended Operating Range 150 100 50 0 10 20 30 40 50 60 Flow (lpm) 24 70 80 90 100 110 Constant Pressure – SubDrive QuickPAK 45 LPM – 3m³/h Depth to Pumping Water Level, or Lift, in Metres Shaded Areas Indicate Most Efficient Performance kW Metres 3.7 0 5 10 20 30 40 50 60 70 80 90 100 110 120 Shut-off Metres 5 10 15 20 25 30 97 94 93 98 96 93 92 97 94 93 91 98 96 93 92 90 97 94 93 91 89 98 96 93 92 90 88 5 10 15 20 25 30 35 40 45 50 97 94 93 91 89 87 98 96 93 92 90 88 86 97 94 93 91 89 87 86 98 96 93 92 90 88 86 85 35 40 45 50 60 80 100 98 97 96 93 92 90 88 86 85 83 81 78 76 73 100 98 96 93 92 90 88 86 85 83 98 96 93 92 90 88 86 85 83 81 78 60 80 Depth to Pumping Water Level, or Lift, in Metres Shaded Areas Indicate Most Efficient Performance Metres 3.7 0 5 10 20 30 40 50 60 70 80 90 100 110 120 Shut-off Metres 120 140 160 180 200 220 240 260 280 300 320 340 360 380 94 93 92 90 88 86 85 83 81 78 76 73 71 68 90 89 88 86 85 83 81 78 76 73 71 68 66 63 86 86 85 83 81 78 76 73 71 68 66 63 60 57 83 82 81 78 76 73 71 68 66 63 60 57 55 52 78 77 76 73 71 68 66 63 60 57 55 52 49 47 73 72 71 68 66 63 60 58 55 52 49 47 44 40 68 67 66 63 60 58 55 52 49 47 44 40 37 33 63 62 60 58 55 52 49 47 44 40 37 33 28 22 58 56 55 52 49 47 44 40 37 33 28 22 52 51 49 47 44 40 37 33 28 22 47 45 44 40 37 33 28 22 40 39 37 33 28 22 33 30 28 22 22 19 120 140 160 180 200 220 240 260 280 300 320 340 360 380 Shut-off 405M kW NOTE: Running outside of ‘Recommenced Operating Range’ for short periods of time is permissible. Actual maximum performance of the SubDrive QuickPAK system is power limited by the SubDrive unit. This limit is based on the maximum allowable AMP load of the submersible motor. The result is that in some installations an 80 Hz speed may not be attained. Flow Rate Units = LPM 25 Constant Pressure – SubDrive QuickPAK SubDrive 300 60 lpm 3 Hp Curve #: 109156101m Date: 9/8/09 SDQP300-60-265 350 300 Total Head (M) 250 200 150 Recommended Operating Range 100 50 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 Flow (lpm) 60 LPM – 3.5m³/h Depth to Pumping Water Level, or Lift, in Metres Shaded Areas Indicate Most Efficient Performance 3.7 0 5 10 20 30 40 50 60 70 80 90 Shut-off Metres 5 10 15 20 25 30 35 40 45 50 60 80 100 120 140 160 180 200 220 240 260 280 132 130 128 125 122 119 116 112 109 105 100 125 123 122 119 116 112 109 105 100 96 92 119 117 116 112 109 105 100 96 92 87 83 113 111 109 105 100 96 92 87 83 78 73 105 102 100 96 92 87 83 78 73 67 58 96 94 92 87 83 78 73 67 58 47 31 87 85 83 78 73 67 58 47 31 78 76 73 67 58 47 31 67 63 58 47 31 132 130 132 130 128 126 132 130 128 126 125 123 132 130 128 126 124 123 122 120 132 128 125 122 119 132 128 125 122 119 116 132 128 125 122 119 116 112 109 10 50 60 80 100 120 140 160 180 200 220 240 260 280 15 20 25 30 35 40 45 NOTE: Running outside of ‘Recommenced Operating Range’ for short periods of time is permissible. Actual maximum performance of the SubDrive QuickPAK system is power limited by the SubDrive unit. This limit is based on the maximum allowable AMP load of the submersible motor. The result is that in some installations an 80 Hz speed may not be attained. 26 47 40 31 Flow Rate Units = LPM Shut-off 301M kW Metres 5 Constant Pressure – SubDrive QuickPAK SubDrive 300 70 lpm 3 Hp Curve #: 109157101m Date: 9/8/09 SDQP300-70-240 300 250 Total Head (M) 200 150 Recommended Operating Range 100 50 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 Flow (lpm) 70 LPM – 4m³/h Depth to Pumping Water Level, or Lift, in Metres Shaded Areas Indicate Most Efficient Performance 3.7 0 5 10 20 30 40 50 60 70 80 90 Shut-off Metres 10 15 20 25 30 35 40 45 50 60 80 100 120 140 160 180 200 220 240 151 149 147 145 144 142 141 5 10 149 145 142 140 151 147 144 141 138 149 145 142 140 136 151 147 144 141 138 135 15 20 25 30 149 145 142 140 136 133 151 147 144 141 138 135 131 149 145 142 140 136 133 129 151 147 144 141 138 135 131 127 35 40 45 50 151 147 144 141 138 135 131 127 122 147 145 144 141 138 135 131 127 122 117 112 141 140 138 135 131 127 122 117 112 107 102 135 133 131 127 122 117 112 107 102 97 92 127 124 122 117 112 107 102 97 92 86 79 117 115 112 107 102 97 92 86 79 69 56 107 105 102 97 92 86 79 69 56 97 95 92 86 79 69 56 86 83 79 70 56 70 63 56 60 80 100 120 140 160 180 200 220 240 Shut-off 258M kW Metres 5 NOTE: Running outside of ‘Recommenced Operating Range’ for short periods of time is permissible. Actual maximum performance of the SubDrive QuickPAK system is power limited by the SubDrive unit. This limit is based on the maximum allowable AMP load of the submersible motor. The result is that in some installations an 80 Hz speed may not be attained. Flow Rate Units = LPM 27 Constant Pressure – SubDrive QuickPAK SubDrive 300 100 lpm 3 Hp Curve #: 109158101m Date: 9/8/09 SDQP300-100-165 220 200 180 Total Head (M) 160 140 120 100 Recommended Operating Range 80 60 40 20 0 50 100 150 200 250 Flow (lpm) 100 LPM – 6m³/h kW Metres 3.7 0 5 10 20 30 40 50 60 70 Shut-off Metres 5 10 15 224 214 205 219 209 201 224 214 205 197 5 10 15 20 25 30 35 219 209 201 193 224 214 205 197 188 219 209 201 193 183 224 214 205 197 188 178 20 25 30 35 40 45 50 60 80 100 120 140 160 180 219 214 209 201 193 183 172 160 148 201 197 193 183 172 160 148 135 123 183 178 172 160 148 135 123 110 96 160 154 148 135 123 110 96 79 57 135 129 123 110 96 79 57 110 104 96 79 57 80 69 57 60 80 100 120 140 160 180 219 209 201 193 183 172 224 214 205 197 188 178 166 224 219 209 201 193 183 172 160 40 45 50 NOTE: Running outside of ‘Recommenced Operating Range’ for short periods of time is permissible. Actual maximum performance of the SubDrive QuickPAK system is power limited by the SubDrive unit. This limit is based on the maximum allowable AMP load of the submersible motor. The result is that in some installations an 80 Hz speed may not be attained. Flow Rate Units = LPM 28 Shut-off 205M Depth to Pumping Water Level, or Lift, in Metres Shaded Areas Indicate Most Efficient Performance Constant Pressure – SubDrive QuickPAK SubDrive 300 150 lpm 3 Hp Curve #: 109159101m Date: 9/9/09 SDQP300-150-118 180 160 140 Total Head (M) 120 100 80 Recommended Operating Range 60 40 20 0 50 100 150 200 250 300 Flow (lpm) 150 LPM – 9m³/h kW Metres 3.7 0 5 10 20 30 40 50 60 70 Shut-off Metres 5 10 15 20 25 30 263 248 232 271 256 240 223 263 248 232 215 271 256 240 224 206 263 248 232 215 196 271 256 240 224 206 187 5 10 15 20 25 30 35 40 45 50 60 80 100 120 140 160 271 263 256 240 224 206 187 166 144 256 248 240 224 206 187 166 144 120 224 215 206 187 166 144 120 94 67 187 177 166 144 120 94 67 39 11 144 132 120 94 67 39 11 94 81 67 39 11 39 25 11 50 60 80 100 120 140 160 263 248 232 215 196 176 271 256 240 224 206 187 166 271 263 248 232 215 196 176 155 35 40 45 Shut-off 174M Depth to Pumping Water Level, or Lift, in Metres Shaded Areas Indicate Most Efficient Performance NOTE: Running outside of ‘Recommenced Operating Range’ for short periods of time is permissible. Actual maximum performance of the SubDrive QuickPAK system is power limited by the SubDrive unit. This limit is based on the maximum allowable AMP load of the submersible motor. The result is that in some installations an 80 Hz speed may not be attained. Flow Rate Units = LPM 29 Constant Pressure – SubDrive QuickPAK SubDrive 300 200 lpm 3 Hp Curve #: 109160101m Date: 9/9/09 SDQP300-200-82 140 130 120 110 Total Head (M) 100 90 80 70 60 50 Recommended Operating Range 40 30 20 10 0 50 100 150 200 250 300 350 400 Flow (lpm) 200 LPM – 12m³/h kW Metres 3.7 0 5 10 20 30 40 50 60 70 Shut-off Metres 5 10 15 357 328 296 260 223 343 312 279 242 204 357 328 296 260 223 185 5 10 15 20 25 30 35 40 45 50 60 80 100 357 343 328 296 261 223 185 150 117 343 328 312 279 242 204 168 133 328 312 296 261 223 186 150 117 312 296 279 242 204 168 134 279 261 242 204 168 134 204 186 168 134 134 117 35 40 45 50 60 80 100 343 312 279 242 204 167 357 328 296 261 223 185 150 357 343 312 279 242 204 168 133 20 25 30 Shut-off 129M Depth to Pumping Water Level, or Lift, in Metres Shaded Areas Indicate Most Efficient Performance NOTE: Running outside of ‘Recommenced Operating Range’ for short periods of time is permissible. Actual maximum performance of the SubDrive QuickPAK system is power limited by the SubDrive unit. This limit is based on the maximum allowable AMP load of the submersible motor. The result is that in some installations an 80 Hz speed may not be attained. Flow Rate Units = LPM 30 Constant Pressure – SubDrive QuickPAK SubDrive 300 270 lpm 3 Hp Curve #: 109161101m Date: 9/9/09 SDQP300-270-60 90 80 70 Total Head (M) 60 50 40 Recommended Operating Range 30 20 10 0 50 100 150 200 250 300 350 400 450 500 550 600 Flow (lpm) 270 LPM – 16m³/h kW Metres 3.7 0 5 10 20 30 40 50 60 70 Shut-off Metres 5 10 558 481 392 302 224 522 438 346 262 185 5 10 15 20 558 482 392 303 224 558 522 438 346 262 185 15 20 25 30 35 40 45 50 60 558 522 482 392 303 224 522 482 438 346 262 185 482 438 392 303 224 438 392 346 262 185 392 347 303 224 347 303 262 186 262 224 186 25 30 35 40 45 50 60 Shut-off 83m Depth to Pumping Water Level, or Lift, in Metres Shaded Areas Indicate Most Efficient Performance NOTE: Running outside of ‘Recommenced Operating Range’ for short periods of time is permissible. Actual maximum performance of the SubDrive QuickPAK system is power limited by the SubDrive unit. This limit is based on the maximum allowable AMP load of the submersible motor. The result is that in some installations an 80 Hz speed may not be attained. Flow Rate Units = LPM 31 AUSTRALIA / NEW ZEALAND Franklin Electric (Australia) Pty. Ltd. 106-110 Micro Circuit Dandenong South, Victoria 3175 Australia Toll Free: 1 300 FRANKLIN 1300 372 655 Fax: +61 3 9799 5050 Tel: +61 3 9799 5000 www.franklin-electric.com.au United States Franklin Electric Co., Inc. 400 E. Spring Street, Bluffton, IN 46714 USA Tel: +1.260.824.2900 Fax: +1.260.824.2909 FE781 03/12