ACOLAN 550 UF

advertisement
ACOLAN 550 UF
Horizontal cable 10 Gigabit Ethernet U/FTP - Category 6a - 4P & 2x4P LSOH
Applications
10 Gigabit high speed data transmission cables are designed for horizontal cable distribution local
computer networks.
These cables allow the use of the protocol supported by the EA class for the 10 GBASE-T application.
They are characterized of up to 550 MHz.
Colour code
Cable construction
- Conductor diameter : 23AWG
- Insulation
: Pe ∅ 1,45 mm
- Cable assembly
: pairs
Number of pairs : 4 and 8 (2x4)
- Individual screen around each pair : Alu/Polyester tape
- Drain wire
- Sheath material
: LSOH
Blue
Orange
Green
Brown
+
+
+
+
Fire resistance
Directive / standard
Applications
Cables
Cabling
System
IEEE 802.3
White
White
White
White
Draft IEC 61156-5 ed. 2
Draft EN 50288-10
Cabling system
installation
standards
Directive
Sheath LSOH
EN 50174
RoHS 2002/95/EC
IEC 60332-1
NF C 32-070 2.1 (C2)
(low smoke emission)
IEC 60754-1
IEC 60754-2
IEC 61034
standard
IS 11801 ed.2
EN 50173-1
EIA/TIA 568
Additional information and references
Reference
Colour
Max diameter
Weight
mm
Kg/km
PCS
(superior calorific capacity)
MJ/Km
KWh/m
Max. pulling
tension (N)
ACOLAN 550 UF 4P LSOH
R7293
Ivory
8,00
57
674
0,187
78
ACOLAN 550 UFD 2x4P LSOH
R7294
Ivory
8,00x16,20
116
1 380
0,383
156
Reel packaging
Type of cable
4P
2x4P
Palettes packaging 1200 x 800
Length
Drum
Weight loaded drum
(kg)
500 m
KL
32
500 m
XL
64
Type of cable
4P
2x4P
Length
Drum
500 m
12
Weight loaded palette
(kg)
398
500 m
4
270
ACOME 52, Rue du Montparnasse – 75014 PARIS – France – T. +(33) 1.42.79.14.00 – F. +(33) 1.42.79.15.00
E-mail : BRTC@acome.fr - Web site : acome.com
Rev. 2006-10-30
Type
1
ACOLAN 550 UF
Horizontal cable 10 Gigabit Ethernet U/FTP - Category 6a - 4P & 2x4P LSOH
Mechanical characteristics
Bending radius
Temperature range
Dynamic (installation)
≥ 70 mm
Static (installed)
≥ 35 mm
In service
- 20°C at + 60°C
At the installation
0°C at + 50°C
Transport and storage
0°C at + 50°C
Electrical characteristics at 20°C
Complete conductor resistance
≤ 146,4 Ω / km
Resistance unbalance
≤2%
Dielectric strength
Continuous current 50 Hz
1kV during 1 minute = no breakdown
Insulation resistance
(500 V)
≥ 5000 MΩ . km
Capacitance unbalance
Real-ground
≤ 1600 pF / km
Characteristic impedance
at 100 MHz
100 ± 5 Ω
Velocity
nominal
78 %
Transfer impedance
at
≤ 50 mΩ / m
1 MHz
at 10 MHz
≤ 50 mΩ / m
at 30 MHz
≤ 70 mΩ / m
at 100 MHz
≤ 100 mΩ / m
Transmission characteristics at 20°C (indicatives values not contractual pending of the standardization)
Frequency
(MHz)
Max. attenuat.
(dB/100m)
Next
(dB)
PS Next
(dB)
ELFEXT
(dB/100 m)
PS ELFEXT
(dB/100 m)
Return Loss
(dB)
PS ANEXT
(dB)
4
10
20
62.5
100
250
500
550**
3.6
5.6
8
14.2
18.1
28.9
41.2
43.5
3.8
5.9
8.4
15
19.1
31.1
45.3
-
90
90
82
75
72
65
60
59
65.3
59.3
54.8
47.4
44.3
38.3
33.8
-
Typical value
87
87
79
72
69
62
57
56
Cat. 6a* (min.)
63.3
57.3
52.8
45.4
42.3
36.3
31.8
-
Typical value
Cat.
6a*
(max.)
Typical value
Cat.
6a*
(min.)
Typical value
80
80
77
71
67
52
46
45
Cat. 6a* (min.)
58
50
44
34.1
30
22
16
-
Typical value
77
77
74
68
64
49
43
42
(min.)
55
47
41
31.1
27
19
13
-
Typical value
25
26
26
23
22
19
18
16
23
25
25
21.5
20.1
17.3
17.3
-
Cat.
Cat.
6a*
6a*
(min.)
Typical value
85
85
85
85
80
73
68
67
Cat. 6a* (min.)
76.5
72.5
69.5
64.5
62.5
56.5
52
-
* Category 6a acc. to Draft IEC 61156-5 Ed.2
** For information only
ACOME 52, Rue du Montparnasse – 75014 PARIS – France – T. +(33) 1.42.79.14.00 – F. +(33) 1.42.79.15.00
E-mail : BRTC@acome.fr - Web site : acome.com
2
Download