City of Blaine

advertisement
CITY OF BLAINE
REQUEST FOR BIDS
NOTICE IS HEREBY GIVEN that the City of Blaine is seeking bids for the purchase of various KVA
sizes of 3 Phase Transformers.
A bid package may be obtained, at no cost, on the City’s website (cityofblaine.com) or by faxing
inquiries to (360) 332-7124. All bids must be delivered to Blaine Public Works, 1200 Yew Avenue,
Blaine, WA 98230, no later than 10:00 am PST, March 9, 2016. The City reserves the right to reject
any or all bids, waive technicalities or irregularities, and accept any submittals if such action is
determined to be in the best interest of Blaine.
Sheri Sanchez, CMC
Administrative Services Director/City Clerk
Published: February 26, 2016
Page 1 of 25
BIDDING INSTRUCTIONS
1.
Bidders are required to reply to all items listed in the specifications. Attach any information
necessary to explain or clarify your bid. Any exceptions to given specifications must be explained in
detail.
2.
Proposed modification to a standard production unit, required to satisfy bid specifications, shall
be submitted with bid. Include a complete detailed explanation and drawing of proposed modifications.
All equipment cataloged as standard and all current production changes shall be furnished with the
equipment offered.
3.
Equipment shall conform to all legal requirements of Federal, State, and local vehicle laws and
regulations. Should minimum requirements conflict with regulations, bidder shall notify the Public
Works Department in writing prior to bid, of conflict and alternatives. The Public Works Department
shall determine which option, if any will be selected.
4.
Prices are to be stated in the units of issue in this invitation. Prices quoted shall be in U.S. funds
and include applicable federal duty, brokerage fees, packaging and transportation cost to the f.o.b. point
so that upon transfer of title, the commodity can be utilized without further cost, except that generated by
the City.
5.
Bids shall include Federal, State, and local taxes. Unless otherwise indicated in the Invitation to
Bid, Washington State sales tax must be included on the bid sheet as a separate line item.
6.
Bidders are requested to review this Invitation carefully, without delay, for defects and
questionable or objectionable matter. Questions, objections or comments should be made in writing and
received by the issuing office no later than 10 days prior to the bid opening, so that any necessary
amendments may be published and distributed to bidders to prevent the opening of a defective bid.
Bidders’ protests based upon any omission, or errors, or content of the Invitation to Bid will be
disallowed if not made known prior to the bid opening.
7.
This award shall be subject to RCW 39.34 Interlocal Cooperation Act wherein other government
agencies may purchase on the City bid request, in accordance with the terms and prices stated, over the
subsequent time period for which the bidder is willing to honor the bid price.
8.
The City of Blaine will NOT accept bids sent by facsimile machines (FAX).
9.
Unsuccessful bidders will not automatically be notified of bid results but may obtain results on
request.
10.
The Public Works Department will make any changes to the original bid specifications in
writing.
BID CONDITIONS
1.
Bids will not be accepted if received at the issuing office later than the date and time set for
opening. All bid envelopes should be clearly marked “TRANSFORMER BID,” and show the date of
opening. The bid label shall be attached to the bid envelope. It is the Bidder’s responsibility to deliver
the bid to the proper address by the assigned time. The City accepts no responsibility for misdirected or
lost bids prior to the bid opening.
Page 2 of 25
2.
The City reserves the right to reject any and all bids, to waive minor deviations from the
specifications, or to waive any informality in bids received, whenever such rejected or waiver is in the
best interest of the City. Among other things a bid may be rejected when: (1) the bidder is in arrears on
taxes or other claims due the City; (2) the bidder is not in a position to perform the contract; (3) the bid is
not signed; (4) the bidder fails to furnish bid bonds or surety deposits, plans specifications, samples, etc.,
when such were specifically called for in the Invitation to Bid; (5) the bidder has failed to use the
proposal form attached; (6) the bidder makes a material change in the specifications, terms or conditions
of the Invitation to Bid; (7) the bid contains a material alteration or erasure which is not initialed by the
signer of the bid; (8) any other reason determined to be in the best interest of the City.
3.
Where the description of an item includes specifications and a brand name and number, the
specifications shall govern in case of conflict. Brand name and number are for reference as to the type
and quality required and do not preclude offers of a comparable or better product, provided full
specifications and descriptive literature accompany the offer. Failure to include full descriptive literature
may be cause to reject the offer. Determination of product acceptability is at the sole discretion of the
City and City Staff.
4.
In case of error in the extension of prices in the bid, the unit prices will govern.
5.
Assignment of contract or bid award shall not be permitted unless authorized in advance by the
City Council.
6.
Prices quoted in accordance with this Invitation to Bid shall be good and firm for a period of 90days from the date of bid opening unless the City specifies a different period of time. A purchase order
issued within the 90-day period shall constitute acceptance of the bid and the bid prices even though
delivery and payment may fall beyond the 90-day period.
7.
In case of default by the vendor, for whatever reason, the City of Blaine may procure the
material or services from other sources and hold the bidder responsible for any excess cost occasioned
thereby. In the event of damage to City property in the performance of a contract, the primary vendor
will be held responsible and reimburse the City to the extent of damage.
8.
The vendor shall hold and save the City, its officers, agents and employees, harmless from
liability of any nature or kind, including costs and expenses, for or on account of any or all suits or
damages of any character whatsoever resulting from injuries or damages sustained by any person or
persons or property by virtue of performance of this contract, unless such suits or damages arise from
negligence on the part of the City or its employees in the performance of their assigned duties. The City
shall not be liable for any costs incurred by the bidder in bid preparation.
9.
Unless otherwise stated in the Invitation to Bid the term “final destination” is defined as City of
Blaine, Public Works, City Shop, 1200 Yew Avenue, Blaine, WA 98230. Unless otherwise stated in the
Invitation to Bid, the successful bidder shall prepay the necessary charges to cause his agent, or the
common carrier, to off-load the goods from the delivering vehicle and place them on the unloading point
at final destination and to be free of any further charges. Unless otherwise stated, the contractor shall
prepay all shipping charges to the receiving point.
10.
Bidder may withdraw its proposal at any time prior to the scheduled closing only if done in
writing.
11.
Unless otherwise specified, the successful bidder will be required to obtain all necessary and
lawful permits and licenses required by the City of Blaine and the State of Washington.
Page 3 of 25
QUESTIONS
All questions regarding this Invitation to Bid may be directed to Wayne Mathers at (360) 332.8820 or by
email to wmathers@cityofblaine.com
BIDDERS MUST COMPLY WITH CIVIL RIGHTS
AND EQUAL EMPLOYMENT OPPORTUNITY ACT
By signature on the bid form, the vendor indicates that he is complying with the applicable portion of the
Federal Civil Rights Act of 1964, and the Equal Employment Opportunity Act and the regulations issued
thereunder by the State and Federal Government. If any bidder fails to comply with the act or the
regulations issued thereunder, the City reserves the right to terminate the contract.
Page 4 of 25
BID PROPOSAL FORM
Price quoted does not include Washington State sales or use tax, but do include all other applicable taxes,
freight and customs levies. Washington State sales tax is stated separately and the applicable percent is
shown on bid proposal form.
Minimum order quantities or any other special conditions are indicated below or on separate sheet if
needed.
________________________________________________________________________
________________________________________________________________________
________________________________________________________________________
________________________________________________________________________
Bidder: _________________________________________________________________
By (Print Name and Title): _________________________________________________
Address: ________________________________________________________________
________________________________________________________________________
Signature: _____________________________________ Phone: ___________________
ACKNOWLEDGEMENT OF RECEIPT OF ADDENDA:
No. __________
Date ___________
___________________________
Bidder/Vendor
No. _________ Date ____________
______________________________
Signature
Page 5 of 25
BID PROPOSAL FORM
ELECTRICAL TRANSFORMER
Item
No.
Quantity
1
2 Each
Item With Written Unit Price
Description
Unit Price
500 Kva Three Phase Pad Mounted (277/480)
Dollars
$
(Written Unit Price)
2
1 Each
1500 Kva Three Phase Pad Mounted (277/480)
$
(Written Unit Price)
1 Each
75 Kva Three Phase Pad Mounted (120/208)
Dollars
1 Each
$
150 Kva Three Phase Pad Mounted (120/208)
Dollars
1 Each
$
300 Kva Three Phase Pad Mounted (120/208)
Dollars
1 Each
$
500 Kva Three Phase Pad Mounted (120/208)
Dollars
1 Each
$
each
$
(Written Unit Price)
7
$
each
(Written Unit Price)
6
$
each
(Written Unit Price)
5
$
each
(Written Unit Price)
4
$
each
Dollars
3
Total
$
each
1000 Kva Three Phase Pad Mounted (120/208)
Dollars
$
(Written Unit Price)
$
each
TOTAL ITEMS
$
Dollars
Cents
(Written Bid Price)
Washington Sales Tax Stated Separately (8.5%)
The City reserves the right to reject any or all bids, or any part thereof,
to waiver irregularities or informalities in the bid or bidding process.
$
REV 5/04
SECTION 16465
OIL-FILLED PAD MOUNTED TRANSFORMERS—THREE-PHASE
PART 1
1.1
GENERAL
REFERENCES
A.
B.
C.
1.2
SUBMITTALS
A.
B.
C.
1.3
Shop Drawings:
1.
Descriptive information.
2.
Dimensional drawings.
3.
Transformer nameplate data.
4.
Schematic and connection diagrams.
Quality Control Submittals:
1.
Operation and maintenance manual.
2.
Factory test reports certified for transformers 500 kVA and larger.
Transformer Equipment Information Statement (EIS). The tabulated information
request, listed at the end of this section, shall be submitted with the Quotation
Proposal for each transformer rated 500 kVA or greater.
EXTRA MATERIALS
A.
1.4
Transformers shall be designed, fabricated, tested and assembled in accordance
with the latest applicable ANSI, IEEE and NEMA standards and NEC
specifications.
Transformer construction shall conform with the Uniform Building Code (UBC)
Section 2312, Earthquake Requirements.
Transformer’s construction shall bear the ENERGY SEAL® efficiency label.
Furnish, tag, and box for shipment and storage of one quart of paint to match
color and quality of equipment final shop finish, and two spare fuses and fuse
links for each bayonet type fuse size.
WARRANTIES
A.
Equipment furnished under these Specifications shall be guaranteed against
defective parts and workmanship under terms of manufacturer's standard
warranty, but in no event shall it be for a period of less than 1 year from date of
initial energization of system and shall include labor and travel time for necessary
repairs at job site.
Section 16465
PART 2
2.1
PRODUCTS
GENERAL
A.
B.
C.
2.2
H.
I.
kVA Rating: See Data Sheet.
Primary Voltage: See Data Sheet.
Secondary Voltage: See Data Sheet.
BIL Rating: See Data Sheet.
Temperature Rise: See Data Sheet.
Impedance: See Data Sheet.
Primary Taps:
1.
Externally operated no-load tap changer.
2.
Provisions for locking handle in any position.
Wye-wye transformers wound on five-legged cores.
Sound Level: In accordance with manufacturer's standards.
ENCLOSURE
A.
B.
C.
2.4
Provide newly manufactured (not rebuilt), dead-front pad-mounted transformers
in accordance with the requirements herein as well as the Data Sheets provided
for each individual transformer. Requirements of the written specifications and
the Data Sheets are complementary. In the event of a conflict between the
requirements of this section and the Data Sheets, the Data Sheets shall take
precedence.
Integral Unit: Provide a compartmental type unit consisting of transformer, oilfilled tank, and high and low voltage terminating compartments, assembled on a
common structural base.
Anchor Bolts: Provide type 316 stainless steel mounting anchor bolts, as
necessary and as sized by equipment manufacturer.
TRANSFORMER
A.
B.
C.
D.
E.
F.
G.
2.3
Oil-Filled Pad Mounted Three-Phase Transformer
In accordance with ANSI C57.12.28 requirements.
Welded carbon steel tank, with cooling panels when required, and lifting eyes.
12-gauge sheet steel terminal compartment enclosure, tamper-resistant having no
exposed screws, bolts, or other fasteners which are externally removable.
TERMINAL COMPARTMENTS
A.
General: ANSI C57.12.28, enclosed high and low voltage compartments side by
side, separated by steel barrier, bolted to transformer tank.
1.
Doors:
a.
Individual, full-height.
b.
Low voltage door with three-point latching mechanism, vault type
handle, and single padlocking provision.
c.
High voltage door fastenings unaccessible until low voltage door has
been opened.
d.
Door Bolts: Penta-head type.
Section 16465
Oil-Filled Pad Mounted Three-Phase Transformer
e.
f.
g.
2.5
BUSHINGS
A.
B.
2.6
Internal, oil-immersed, gang-operated load break, manually operated switches.
Hot stick operated handle located in high voltage compartment.
Capable of operating at full-load current.
HIGH VOLTAGE PROTECTION
A.
2.8
High Voltage:
1.
Deadfront Termination:
a.
Universal bushing well rated at 15 kV in accordance with ANSI 386.
b.
Molded epoxy bushings, externally clamped and front removable.
c.
Standoff brackets located adjacent to bushings.
Low Voltage:
1.
Molded epoxy bushings, externally clamped to tank with NEMA stud type
terminals.
2.
Rated 150 percent of continuous full-load current, 30 kV BIL, 600 volts.
3.
Internally connected neutral extending to neutral bushing.
HIGH VOLTAGE SWITCHING
A.
B.
C.
2.7
Lift-off, stainless steel hinges and door stops.
Removable front sill to facilitate rolling or skidding over conduit
stubs.
Recessed lock pocket, with steel door release bolt adjacent to
secondary compartment door handle.
Combination Oil-Immersed Bayonet Expulsion and Current Limiting Fuses:
1.
Accessibility:
a.
Bayonet expulsion fuse accessible through primary compartment.
b.
Current-limiting fuse accessible through tank handhole.
2.
Expulsion Fuse for Low Current Faults: Interrupting capacity of
1,800 amperes rms asymmetrical.
3.
Current Limiting for High Current Faults: Interrupting capacity of
50,000 amperes rms symmetrical.
4.
Bayonet fuse externally replaceable with hot stick.
SURGE ARRESTERS
A.
B.
C.
Distribution Class Type: live front, with mounting bracket in accordance with
ANSI C62.11.
Elbow Valve Type: Un-insulated body, with barriers in accordance with
ANSI C62.11.
Metal-Oxide, Varistor Type:
1.
Insulated body, elbow type, in accordance with ANSI C62.11.
2.
Installed in high voltage compartment.
3.
Connected to transformer high voltage terminals.
Section 16465
2.9
TANK GROUNDING PADS
A.
2.10
B.
PART 3
Transformers shall be numbered as required by the City of Blaine.
EXECUTION
GENERAL
A.
B.
C.
3.2
Production tests in accordance with ANSI C57.12.90 and C57.12.00, Section 8
and Table 16.
Dielectric test in accordance with ANSI C57.12.26.
MARKING
A.
3.1
White laminated plastic, engraved to red core.
Engrave to read DO NOT OPERATE WHEN TRANSFORMER ENERGIZED.
Mount above tap changer handle.
FACTORY TESTS
A.
2.12
High and Low Voltage Compartments:
1.
Connected together with bare No. 2/0 stranded copper conductors.
2.
Wye-wye high and low voltage neutrals internally connected with link and
brought out to insulated low voltage bushing externally grounded to tank.
3.
Low voltage neutral connected to externally mounted insulating bushing in
low voltage compartment and grounded to tank with removable strap.
TAP CHANGER WARNING SIGN
A.
B.
C.
2.11
Oil-Filled Pad Mounted Three-Phase Transformer
Secure to mounting pads with anchor bolts.
Install plumb and longitudinally in alignment with pad or adjacent building.
Ground neutrals and enclosures in accordance with applicable codes.
SITE TESTING
A.
B.
C.
D.
Performance tests made in the field are to be made at times and under conditions
to be mutually agreed upon by Owner and Contractor.
Contractor shall provide certified copies of all performance tests to Owner.
When specific performance tests are required, the work on the apparatus shall not
proceed beyond that point until Owner has reviewed and approved certified
reports of all performance tests or waived such review and approval.
Provide all necessary tools, cables, and equipment to support the following site
tests:
1.
Turns ratio test: Perform test on all tap settings.
2.
Insulating oil dielectric test.
3.
Insulating oil gasification test.
4.
Megger test.
Section 16465
3.3
ADJUSTMENTS
A.
3.4
Oil-Filled Pad Mounted Three-Phase Transformer
Adjust voltage taps to obtain rated output voltage under normal operating load
conditions.
REQUIRED INFORMATION TO BE SUBMITTED WITH PROPOSAL
A.
In addition to forms and documents required to be submitted with the Quotation
Proposal, the following information must be included and titled Bidder’s
Equipment Information Statement (EIS) for transformer(s) rated 500 kVA or
greater. The EIS shall be submitted in a list format with item numbers which
correspond to the items listed below:
1.
Listing of exceptions taken to the document.
2.
Description of core and coil construction and materials.
3.
Description of protection, pressure relief, and safety devices.
4.
Description of manual tap changer.
5.
Guaranteed no-load (core) losses at rated voltage for each bid item.
6.
Guaranteed load (copper) losses, including auxiliary losses, at rated kVA
and voltage for each bid item.
END OF SECTION
BID ITEM 1 - DATA SHEET
THREE-PHASE PAD-MOUNTED DISTRIBUTION TRANSFORMER
(45-2500kVA)
In the case of conflicts, Data Sheet take precedence over Specifications.
EQUIPMENT TAG NUMBER
____________________
Location
[x] Outdoor
RATING:
500
Temperature Rise:
Liquid Type:
kVA, 3-phase
[x] 65C
Frequency:
[ ] 55/65C
[x]
ANSI Standard
[ ] Indoor
[ ] 50 HZ
[x] 60 HZ
Cooling:
[ ] 55C
[ ] OA
[ ] _______
[ ] Other_______________
[x] Non-PCB Mineral Oil
Impedance:
Size:
[ ] Outdoor, near building
[ ]
______% Nominal
[ ]
_______ Maximum
[ ]
______%Minimum
[ ] Compact Size_______________
[x] Standard Size
PRIMARY
Voltage (Line to Line):
[ ]
Delta – Wye
Connection:
Primary Connection:
Primary
Switches:
Primary
Fusing:
[ ]
Grounded Wye - Wye
[ ]
4 @ 2.5%
below
Primary Taps
Primary
Bushings:
12470/GRY/7200 Volts
[ ]
Wells Only
(200 A)
[x]
4 @ 2.5%
above
95 kV
BIL:
[ ]
Delta -Delta
[ ]
None
[ ] Radial Feed (Dead Front)
[x]
Wells and
Inserts (200 A)
[ ]
Wye- Delta
[ ]
NEMA Std
2-2.5% above
2-2.5% below
[ ] Other:
__________
[x] Loop Feed (Dead Front)
[ ]
Wells and Feed thru
Inserts (200 A)
[x] On/Off Loadbreak Switch
[ ] 4-Position Sectionalizing Switch
[ ] Two On/Off Loadbreak Switches
[ ] Three On/Off Loadbreak Switches
[x]
Wye –Wye
[ ]
Deadbreak OnePiece Bushings
(600 A)
[ ] T-Blade Switch
[ ]
Wells with
Removable Studs
(200 A)
[ ] V-Blade Switch
[x] Bayonet Expulsion Fuse with Isolation Link
[ ] Bayonet Expulsion Fuse in Series with Partial Range Internal Current Limiting Fuse
[ ] Dual Sensing
[ ] Current Sensing
[ ] Drywell Canister Fuse
[ ] Non-Loadbreak
[ ] Loadbreak
[ ] Expulsion Cartridge Fuse
[ ] None
Arrestors:
(Distribution Class)
Rating: ________ kV
[ ] Elbow Arresters
[ ] External Arresters
[ ] Under-oil Arresters
[x] None
SECONDARY
Voltage:
277/480 Volts
[ ] wye
[ ] ___-Hole Spade
[x] 4-Stud
Secondary Bushings:
[ ] delta
30 kV
BIL:
[ ] Supported (standard for 10-hole and above)
[ ] - Standard
OPTIONS & ACCESSORIES
Dollars/kW (No Load):
Dollars/kW (Load):
Loss Evaluation:
Optional
Accessories:
Special Features:
$
$
3,167 /kW
1,206 /kW
[x]
Liquid Level Gauge
[x]
Pressure/Vacuum Gauge
[ ]
[ ]
30” Extended Depth Cabinet
[ ]
Hexhead Captive Bolt (replaces
Pentahead Bolt)
Breaker Mounting Provisions
[x]
[ ]
[x]
[ ]
Dial Type Thermometer
SS Nameplate
SS Tank Base & Cabinet Sides and Sill
[x]
[ ]
[ ]
Reverse positions of Drain Plug
& Valve
HV Warning Signs
SS Tank Base & Cabinet
Nitrogen Blanket with Bleeder
and Purge Valve
[ ]
[ ]
[ ]
2” Service Entrance in Sill
CT Space
PT Space
[ ]
[x]
[ ]
All Copper Windings
Dial Type Thermometer
Globe Type Upper Fill Valve
Color:
[x]
Standard Munsell No.
7GY3.29/1.5 Green
Testing:
[x]
ANSI Standard
[ ]
Certified Test
Results
Operating Conditions:
[ ]
[ ]
Other
[x]
[ ]
[ ]
[ ]
[ ]
[ ]
Liquid Level Gauge
Pressure/Vacuum Gauge
K-Factor Rated
K=9
K=20
K=30
Other ___________________
_______________________________
_______________________________
_______________________________
Maximum Elevation of Installation Site Above Sea Level:
Maximum Ambient Air Temperature:
Minimum Ambient Air Temperature:
Seismic:
feet
degrees f
degrees f
BID ITEM 2 - DATA SHEET
THREE-PHASE PAD-MOUNTED DISTRIBUTION TRANSFORMER
(45-2500kVA)
In the case of conflicts, Data Sheet take precedence over Specifications.
EQUIPMENT TAG NUMBER
____________________
Location
[x] Outdoor
RATING:
1500
Temperature Rise:
Liquid Type:
kVA, 3-phase
[x] 65C
Frequency:
[ ] 55/65C
[x]
ANSI Standard
[ ] Indoor
[ ] 50 HZ
[x] 60 HZ
Cooling:
[ ] 55C
[ ] OA
[ ] _______
[ ] Other_______________
[x] Non-PCB Mineral Oil
Impedance:
Size:
[ ] Outdoor, near building
[ ]
______% Nominal
[ ]
_______ Maximum
[ ]
______%Minimum
[ ] Compact Size_______________
[x] Standard Size
PRIMARY
Voltage (Line to Line):
[ ]
Delta – Wye
Connection:
Primary Connection:
Primary
Switches:
Primary
Fusing:
[ ]
Grounded Wye - Wye
[ ]
4 @ 2.5%
below
Primary Taps
Primary
Bushings:
12470/GRY/7200 Volts
[ ]
Wells Only
(200 A)
[x]
4 @ 2.5%
above
95 kV
BIL:
[ ]
Delta -Delta
[ ]
None
[ ] Radial Feed (Dead Front)
[x]
Wells and
Inserts (200 A)
[ ]
Wye- Delta
[ ]
NEMA Std
2-2.5% above
2-2.5% below
[ ] Other:
__________
[x] Loop Feed (Dead Front)
[ ]
Wells and Feed thru
Inserts (200 A)
[x] On/Off Loadbreak Switch
[ ] 4-Position Sectionalizing Switch
[ ] Two On/Off Loadbreak Switches
[ ] Three On/Off Loadbreak Switches
[x]
Wye –Wye
[ ]
Deadbreak OnePiece Bushings
(600 A)
[ ] T-Blade Switch
[ ]
Wells with
Removable Studs
(200 A)
[ ] V-Blade Switch
[x] Bayonet Expulsion Fuse with Isolation Link
[ ] Bayonet Expulsion Fuse in Series with Partial Range Internal Current Limiting Fuse
[ ] Dual Sensing
[ ] Current Sensing
[ ] Drywell Canister Fuse
[ ] Non-Loadbreak
[ ] Loadbreak
[ ] Expulsion Cartridge Fuse
[ ] None
Arrestors:
(Distribution Class)
Rating: ________ kV
[ ] Elbow Arresters
[ ] External Arresters
[ ] Under-oil Arresters
[x] None
SECONDARY
Voltage:
277/480 Volts
[ ] wye
[ ] ___-Hole Spade
[x] 4-Stud
Secondary Bushings:
[ ] delta
30 kV
BIL:
[ ] Supported (standard for 10-hole and above)
[ ] - Standard
OPTIONS & ACCESSORIES
Dollars/kW (No Load):
Dollars/kW (Load):
Loss Evaluation:
Optional
Accessories:
Special Features:
$
$
3,167 /kW
1,206 /kW
[x]
Liquid Level Gauge
[x]
Pressure/Vacuum Gauge
[ ]
[ ]
30” Extended Depth Cabinet
[ ]
Hexhead Captive Bolt (replaces
Pentahead Bolt)
Breaker Mounting Provisions
[x]
[ ]
[x]
[ ]
Dial Type Thermometer
SS Nameplate
SS Tank Base & Cabinet Sides and Sill
[x]
[ ]
[ ]
Reverse positions of Drain Plug
& Valve
HV Warning Signs
SS Tank Base & Cabinet
Nitrogen Blanket with Bleeder
and Purge Valve
[ ]
[ ]
[ ]
2” Service Entrance in Sill
CT Space
PT Space
[ ]
[x]
[ ]
All Copper Windings
Dial Type Thermometer
Globe Type Upper Fill Valve
Color:
[x]
Standard Munsell No.
7GY3.29/1.5 Green
Testing:
[x]
ANSI Standard
[ ]
Certified Test
Results
Operating Conditions:
[ ]
[ ]
Other
[x]
[ ]
[ ]
[ ]
[ ]
[ ]
Liquid Level Gauge
Pressure/Vacuum Gauge
K-Factor Rated
K=9
K=20
K=30
Other ___________________
_______________________________
_______________________________
_______________________________
Maximum Elevation of Installation Site Above Sea Level:
Maximum Ambient Air Temperature:
Minimum Ambient Air Temperature:
Seismic:
feet
degrees f
degrees f
BID ITEM 3 - DATA SHEET
THREE-PHASE PAD-MOUNTED DISTRIBUTION TRANSFORMER
(45-2500kVA)
In the case of conflicts, Data Sheet take precedence over Specifications.
EQUIPMENT TAG NUMBER
Location
[ ] Outdoor, near building
[x] Outdoor
RATING:
kVA, 3-phase
75
Temperature Rise:
Liquid Type:
[x] 65C
Frequency:
[ ] 55/65C
[x]
ANSI Standard
[ ] Indoor
[ ] 50 HZ
[x] 60 HZ
Cooling:
[ ] 55C
[ ] OA
[ ] _______
[ ] Other_______________
[x] Non-PCB Mineral Oil
Impedance:
Size:
____________________
[ ]
______% Nominal
[ ]
_______ Maximum
[ ]
______%Minimum
[ ] Compact Size_______________
[x] Standard Size
PRIMARY
Voltage (Line to Line):
[ ]
Delta – Wye
Connection:
Primary Connection:
Primary
Switches:
Primary
Fusing:
[ ]
Grounded Wye - Wye
[ ]
4 @ 2.5%
below
Primary Taps
Primary
Bushings:
12470/GRY/7200 Volts
[ ]
Wells Only
(200 A)
[x]
4 @ 2.5%
above
95 kV
BIL:
[ ]
Delta -Delta
[ ]
None
[ ] Radial Feed (Dead Front)
[x]
Wells and
Inserts (200 A)
[ ]
Wye- Delta
[ ]
NEMA Std
2-2.5% above
2-2.5% below
[ ] Other:
__________
[x] Loop Feed (Dead Front)
[ ]
Wells and Feed thru
Inserts (200 A)
[x] On/Off Loadbreak Switch
[ ] 4-Position Sectionalizing Switch
[ ] Two On/Off Loadbreak Switches
[ ] Three On/Off Loadbreak Switches
[x]
Wye –Wye
[ ]
Deadbreak OnePiece Bushings
(600 A)
[ ] T-Blade Switch
[ ]
Wells with
Removable Studs
(200 A)
[ ] V-Blade Switch
[x] Bayonet Expulsion Fuse with Isolation Link
[ ] Bayonet Expulsion Fuse in Series with Partial Range Internal Current Limiting Fuse
[ ] Dual Sensing
[ ] Current Sensing
[ ] Drywell Canister Fuse
[ ] Non-Loadbreak
[ ] Loadbreak
[ ] Expulsion Cartridge Fuse
[ ] None
Arrestors:
(Distribution Class)
Rating: ________ kV
[ ] Elbow Arresters
[ ] External Arresters
[ ] Under-oil Arresters
[x] None
SECONDARY
Voltage:
120/208 Volts
[ ] wye
[ ] ___-Hole Spade
[x] 4-Stud
Secondary Bushings:
[ ] delta
30 kV
BIL:
[ ] Supported (standard for 10-hole and above)
[ ] - Standard
OPTIONS & ACCESSORIES
Dollars/kW (No Load):
Dollars/kW (Load):
Loss Evaluation:
Optional
Accessories:
Special Features:
$
$
3,167 /kW
1,206 /kW
[x]
Liquid Level Gauge
[x]
Pressure/Vacuum Gauge
[ ]
[ ]
30” Extended Depth Cabinet
[ ]
Hexhead Captive Bolt (replaces
Pentahead Bolt)
Breaker Mounting Provisions
[x]
[ ]
[x]
[ ]
Dial Type Thermometer
SS Nameplate
SS Tank Base & Cabinet Sides and Sill
[x]
[ ]
[ ]
Reverse positions of Drain Plug
& Valve
HV Warning Signs
SS Tank Base & Cabinet
Nitrogen Blanket with Bleeder
and Purge Valve
[ ]
[ ]
[ ]
2” Service Entrance in Sill
CT Space
PT Space
[ ]
[x]
[ ]
All Copper Windings
Dial Type Thermometer
Globe Type Upper Fill Valve
Color:
[x]
Standard Munsell No.
7GY3.29/1.5 Green
Testing:
[x]
ANSI Standard
[ ]
Certified Test
Results
Operating Conditions:
[ ]
[ ]
Other
[x]
[ ]
[ ]
[ ]
[ ]
[ ]
Liquid Level Gauge
Pressure/Vacuum Gauge
K-Factor Rated
K=9
K=20
K=30
Other ___________________
_______________________________
_______________________________
_______________________________
Maximum Elevation of Installation Site Above Sea Level:
Maximum Ambient Air Temperature:
Minimum Ambient Air Temperature:
Seismic:
feet
degrees f
degrees f
BID ITEM 4 - DATA SHEET
THREE-PHASE PAD-MOUNTED DISTRIBUTION TRANSFORMER
(45-2500kVA)
In the case of conflicts, Data Sheet take precedence over Specifications.
EQUIPMENT TAG NUMBER
____________________
Location
[x] Outdoor
RATING:
150
Temperature Rise:
Liquid Type:
kVA, 3-phase
[x] 65C
Frequency:
[ ] 55/65C
[x]
ANSI Standard
[ ] Indoor
[ ] 50 HZ
[x] 60 HZ
Cooling:
[ ] 55C
[ ] OA
[ ] _______
[ ] Other_______________
[x] Non-PCB Mineral Oil
Impedance:
Size:
[ ] Outdoor, near building
[ ]
______% Nominal
[ ]
_______ Maximum
[ ]
______%Minimum
[ ] Compact Size_______________
[x] Standard Size
PRIMARY
Voltage (Line to Line):
[ ]
Delta – Wye
Connection:
Primary Connection:
Primary
Switches:
Primary
Fusing:
[ ]
Grounded Wye - Wye
[ ]
4 @ 2.5%
below
Primary Taps
Primary
Bushings:
12470/GRY/7200 Volts
[ ]
Wells Only
(200 A)
[x]
4 @ 2.5%
above
95 kV
BIL:
[ ]
Delta -Delta
[ ]
None
[ ] Radial Feed (Dead Front)
[x]
Wells and
Inserts (200 A)
[ ]
Wye- Delta
[ ]
NEMA Std
2-2.5% above
2-2.5% below
[ ] Other:
__________
[x] Loop Feed (Dead Front)
[ ]
Wells and Feed thru
Inserts (200 A)
[x] On/Off Loadbreak Switch
[ ] 4-Position Sectionalizing Switch
[ ] Two On/Off Loadbreak Switches
[ ] Three On/Off Loadbreak Switches
[x]
Wye –Wye
[ ]
Deadbreak OnePiece Bushings
(600 A)
[ ] T-Blade Switch
[ ]
Wells with
Removable Studs
(200 A)
[ ] V-Blade Switch
[x] Bayonet Expulsion Fuse with Isolation Link
[ ] Bayonet Expulsion Fuse in Series with Partial Range Internal Current Limiting Fuse
[ ] Dual Sensing
[ ] Current Sensing
[ ] Drywell Canister Fuse
[ ] Non-Loadbreak
[ ] Loadbreak
[ ] Expulsion Cartridge Fuse
[ ] None
Arrestors:
(Distribution Class)
Rating: ________ kV
[ ] Elbow Arresters
[ ] External Arresters
[ ] Under-oil Arresters
[x] None
SECONDARY
Voltage:
120/208 Volts
[ ] wye
[ ] ___-Hole Spade
[x] 4-Stud
Secondary Bushings:
[ ] delta
30 kV
BIL:
[ ] Supported (standard for 10-hole and above)
[ ] - Standard
OPTIONS & ACCESSORIES
Dollars/kW (No Load):
Dollars/kW (Load):
Loss Evaluation:
Optional
Accessories:
Special Features:
$
$
3,167 /kW
1,206 /kW
[x]
Liquid Level Gauge
[x]
Pressure/Vacuum Gauge
[ ]
[ ]
30” Extended Depth Cabinet
[ ]
Hexhead Captive Bolt (replaces
Pentahead Bolt)
Breaker Mounting Provisions
[x]
[ ]
[x]
[ ]
Dial Type Thermometer
SS Nameplate
SS Tank Base & Cabinet Sides and Sill
[x]
[ ]
[ ]
Reverse positions of Drain Plug
& Valve
HV Warning Signs
SS Tank Base & Cabinet
Nitrogen Blanket with Bleeder
and Purge Valve
[ ]
[ ]
[ ]
2” Service Entrance in Sill
CT Space
PT Space
[ ]
[x]
[ ]
All Copper Windings
Dial Type Thermometer
Globe Type Upper Fill Valve
Color:
[x]
Standard Munsell No.
7GY3.29/1.5 Green
Testing:
[x]
ANSI Standard
[ ]
Certified Test
Results
Operating Conditions:
[ ]
[ ]
Other
[x]
[ ]
[ ]
[ ]
[ ]
[ ]
Liquid Level Gauge
Pressure/Vacuum Gauge
K-Factor Rated
K=9
K=20
K=30
Other ___________________
_______________________________
_______________________________
_______________________________
Maximum Elevation of Installation Site Above Sea Level:
Maximum Ambient Air Temperature:
Minimum Ambient Air Temperature:
Seismic:
feet
degrees f
degrees f
BID ITEM 5 - DATA SHEET
THREE-PHASE PAD-MOUNTED DISTRIBUTION TRANSFORMER
(45-2500kVA)
In the case of conflicts, Data Sheet take precedence over Specifications.
EQUIPMENT TAG NUMBER
____________________
Location
[x] Outdoor
RATING:
300
Temperature Rise:
Liquid Type:
kVA, 3-phase
[x] 65C
Frequency:
[ ] 55/65C
[x]
ANSI Standard
[ ] Indoor
[ ] 50 HZ
[x] 60 HZ
Cooling:
[ ] 55C
[ ] OA
[ ] _______
[ ] Other_______________
[x] Non-PCB Mineral Oil
Impedance:
Size:
[ ] Outdoor, near building
[ ]
______% Nominal
[ ]
_______ Maximum
[ ]
______%Minimum
[ ] Compact Size_______________
[x] Standard Size
PRIMARY
Voltage (Line to Line):
[ ]
Delta – Wye
Connection:
Primary Connection:
Primary
Switches:
Primary
Fusing:
[ ]
Grounded Wye - Wye
[ ]
4 @ 2.5%
below
Primary Taps
Primary
Bushings:
12470/GRY/7200 Volts
[ ]
Wells Only
(200 A)
[x]
4 @ 2.5%
above
95 kV
BIL:
[ ]
Delta -Delta
[ ]
None
[ ] Radial Feed (Dead Front)
[x]
Wells and
Inserts (200 A)
[ ]
Wye- Delta
[ ]
NEMA Std
2-2.5% above
2-2.5% below
[ ] Other:
__________
[x] Loop Feed (Dead Front)
[ ]
Wells and Feed thru
Inserts (200 A)
[x] On/Off Loadbreak Switch
[ ] 4-Position Sectionalizing Switch
[ ] Two On/Off Loadbreak Switches
[ ] Three On/Off Loadbreak Switches
[x]
Wye –Wye
[ ]
Deadbreak OnePiece Bushings
(600 A)
[ ] T-Blade Switch
[ ]
Wells with
Removable Studs
(200 A)
[ ] V-Blade Switch
[x] Bayonet Expulsion Fuse with Isolation Link
[ ] Bayonet Expulsion Fuse in Series with Partial Range Internal Current Limiting Fuse
[ ] Dual Sensing
[ ] Current Sensing
[ ] Drywell Canister Fuse
[ ] Non-Loadbreak
[ ] Loadbreak
[ ] Expulsion Cartridge Fuse
[ ] None
Arrestors:
(Distribution Class)
Rating: ________ kV
[ ] Elbow Arresters
[ ] External Arresters
[ ] Under-oil Arresters
[x] None
SECONDARY
Voltage:
120/208 Volts
[ ] wye
[ ] ___-Hole Spade
[x] 4-Stud
Secondary Bushings:
[ ] delta
30 kV
BIL:
[ ] Supported (standard for 10-hole and above)
[ ] - Standard
OPTIONS & ACCESSORIES
Dollars/kW (No Load):
Dollars/kW (Load):
Loss Evaluation:
Optional
Accessories:
Special Features:
$
$
3,167 /kW
1,206 /kW
[x]
Liquid Level Gauge
[x]
Pressure/Vacuum Gauge
[ ]
[ ]
30” Extended Depth Cabinet
[ ]
Hexhead Captive Bolt (replaces
Pentahead Bolt)
Breaker Mounting Provisions
[x]
[ ]
[x]
[ ]
Dial Type Thermometer
SS Nameplate
SS Tank Base & Cabinet Sides and Sill
[x]
[ ]
[ ]
Reverse positions of Drain Plug
& Valve
HV Warning Signs
SS Tank Base & Cabinet
Nitrogen Blanket with Bleeder
and Purge Valve
[ ]
[ ]
[ ]
2” Service Entrance in Sill
CT Space
PT Space
[ ]
[x]
[ ]
All Copper Windings
Dial Type Thermometer
Globe Type Upper Fill Valve
Color:
[x]
Standard Munsell No.
7GY3.29/1.5 Green
Testing:
[x]
ANSI Standard
[ ]
Certified Test
Results
Operating Conditions:
[ ]
[ ]
Other
[x]
[ ]
[ ]
[ ]
[ ]
[ ]
Liquid Level Gauge
Pressure/Vacuum Gauge
K-Factor Rated
K=9
K=20
K=30
Other ___________________
_______________________________
_______________________________
_______________________________
Maximum Elevation of Installation Site Above Sea Level:
Maximum Ambient Air Temperature:
Minimum Ambient Air Temperature:
Seismic:
feet
degrees f
degrees f
BID ITEM 6 - DATA SHEET
THREE-PHASE PAD-MOUNTED DISTRIBUTION TRANSFORMER
(45-2500kVA)
In the case of conflicts, Data Sheet take precedence over Specifications.
EQUIPMENT TAG NUMBER
____________________
Location
[x] Outdoor
RATING:
500
Temperature Rise:
Liquid Type:
kVA, 3-phase
[x] 65C
Frequency:
[ ] 55/65C
[x]
ANSI Standard
[ ] Indoor
[ ] 50 HZ
[x] 60 HZ
Cooling:
[ ] 55C
[ ] OA
[ ] _______
[ ] Other_______________
[x] Non-PCB Mineral Oil
Impedance:
Size:
[ ] Outdoor, near building
[ ]
______% Nominal
[ ]
_______ Maximum
[ ]
______%Minimum
[ ] Compact Size_______________
[x] Standard Size
PRIMARY
Voltage (Line to Line):
[ ]
Delta – Wye
Connection:
Primary Connection:
Primary
Switches:
Primary
Fusing:
[ ]
Grounded Wye - Wye
[ ]
4 @ 2.5%
below
Primary Taps
Primary
Bushings:
12470/GRY/7200 Volts
[ ]
Wells Only
(200 A)
[x]
4 @ 2.5%
above
95 kV
BIL:
[ ]
Delta -Delta
[ ]
None
[ ] Radial Feed (Dead Front)
[x]
Wells and
Inserts (200 A)
[ ]
Wye- Delta
[ ]
NEMA Std
2-2.5% above
2-2.5% below
[ ] Other:
__________
[x] Loop Feed (Dead Front)
[ ]
Wells and Feed thru
Inserts (200 A)
[x] On/Off Loadbreak Switch
[ ] 4-Position Sectionalizing Switch
[ ] Two On/Off Loadbreak Switches
[ ] Three On/Off Loadbreak Switches
[x]
Wye –Wye
[ ]
Deadbreak OnePiece Bushings
(600 A)
[ ] T-Blade Switch
[ ]
Wells with
Removable Studs
(200 A)
[ ] V-Blade Switch
[x] Bayonet Expulsion Fuse with Isolation Link
[ ] Bayonet Expulsion Fuse in Series with Partial Range Internal Current Limiting Fuse
[ ] Dual Sensing
[ ] Current Sensing
[ ] Drywell Canister Fuse
[ ] Non-Loadbreak
[ ] Loadbreak
[ ] Expulsion Cartridge Fuse
[ ] None
Arrestors:
(Distribution Class)
Rating: ________ kV
[ ] Elbow Arresters
[ ] External Arresters
[ ] Under-oil Arresters
[x] None
SECONDARY
Voltage:
120/208 Volts
[ ] wye
[ ] ___-Hole Spade
[x] 4-Stud
Secondary Bushings:
[ ] delta
30 kV
BIL:
[ ] Supported (standard for 10-hole and above)
[ ] - Standard
OPTIONS & ACCESSORIES
Dollars/kW (No Load):
Dollars/kW (Load):
Loss Evaluation:
Optional
Accessories:
Special Features:
$
$
3,167 /kW
1,206 /kW
[x]
Liquid Level Gauge
[x]
Pressure/Vacuum Gauge
[ ]
[ ]
30” Extended Depth Cabinet
[ ]
Hexhead Captive Bolt (replaces
Pentahead Bolt)
Breaker Mounting Provisions
[x]
[ ]
[x]
[ ]
Dial Type Thermometer
SS Nameplate
SS Tank Base & Cabinet Sides and Sill
[x]
[ ]
[ ]
Reverse positions of Drain Plug
& Valve
HV Warning Signs
SS Tank Base & Cabinet
Nitrogen Blanket with Bleeder
and Purge Valve
[ ]
[ ]
[ ]
2” Service Entrance in Sill
CT Space
PT Space
[ ]
[x]
[ ]
All Copper Windings
Dial Type Thermometer
Globe Type Upper Fill Valve
Color:
[x]
Standard Munsell No.
7GY3.29/1.5 Green
Testing:
[x]
ANSI Standard
[ ]
Certified Test
Results
Operating Conditions:
[ ]
[ ]
Other
[x]
[ ]
[ ]
[ ]
[ ]
[ ]
Liquid Level Gauge
Pressure/Vacuum Gauge
K-Factor Rated
K=9
K=20
K=30
Other ___________________
_______________________________
_______________________________
_______________________________
Maximum Elevation of Installation Site Above Sea Level:
Maximum Ambient Air Temperature:
Minimum Ambient Air Temperature:
Seismic:
feet
degrees f
degrees f
BID ITEM 7 - DATA SHEET
THREE-PHASE PAD-MOUNTED DISTRIBUTION TRANSFORMER
(45-2500kVA)
In the case of conflicts, Data Sheet take precedence over Specifications.
EQUIPMENT TAG NUMBER
____________________
Location
[x] Outdoor
RATING:
1000
Temperature Rise:
Liquid Type:
kVA, 3-phase
[x] 65C
Frequency:
[ ] 55/65C
[x]
ANSI Standard
[ ] Indoor
[ ] 50 HZ
[x] 60 HZ
Cooling:
[ ] 55C
[ ] OA
[ ] _______
[ ] Other_______________
[x] Non-PCB Mineral Oil
Impedance:
Size:
[ ] Outdoor, near building
[ ]
______% Nominal
[ ]
_______ Maximum
[ ]
______%Minimum
[ ] Compact Size_______________
[x] Standard Size
PRIMARY
Voltage (Line to Line):
[ ]
Delta – Wye
Connection:
Primary Connection:
Primary
Switches:
Primary
Fusing:
[ ]
Grounded Wye - Wye
[ ]
4 @ 2.5%
below
Primary Taps
Primary
Bushings:
12470/GRY/7200 Volts
[ ]
Wells Only
(200 A)
[x]
4 @ 2.5%
above
95 kV
BIL:
[ ]
Delta -Delta
[ ]
None
[ ] Radial Feed (Dead Front)
[x]
Wells and
Inserts (200 A)
[ ]
Wye- Delta
[ ]
NEMA Std
2-2.5% above
2-2.5% below
[ ] Other:
__________
[x] Loop Feed (Dead Front)
[ ]
Wells and Feed thru
Inserts (200 A)
[x] On/Off Loadbreak Switch
[ ] 4-Position Sectionalizing Switch
[ ] Two On/Off Loadbreak Switches
[ ] Three On/Off Loadbreak Switches
[x]
Wye –Wye
[ ]
Deadbreak OnePiece Bushings
(600 A)
[ ] T-Blade Switch
[ ]
Wells with
Removable Studs
(200 A)
[ ] V-Blade Switch
[x] Bayonet Expulsion Fuse with Isolation Link
[ ] Bayonet Expulsion Fuse in Series with Partial Range Internal Current Limiting Fuse
[ ] Dual Sensing
[ ] Current Sensing
[ ] Drywell Canister Fuse
[ ] Non-Loadbreak
[ ] Loadbreak
[ ] Expulsion Cartridge Fuse
[ ] None
Arrestors:
(Distribution Class)
Rating: ________ kV
[ ] Elbow Arresters
[ ] External Arresters
[ ] Under-oil Arresters
[x] None
SECONDARY
Voltage:
120/208 Volts
[ ] wye
[ ] ___-Hole Spade
[x] 4-Stud
Secondary Bushings:
[ ] delta
30 kV
BIL:
[ ] Supported (standard for 10-hole and above)
[ ] - Standard
OPTIONS & ACCESSORIES
Dollars/kW (No Load):
Dollars/kW (Load):
Loss Evaluation:
Optional
Accessories:
Special Features:
$
$
3,167 /kW
1,206 /kW
[x]
Liquid Level Gauge
[x]
Pressure/Vacuum Gauge
[ ]
[ ]
30” Extended Depth Cabinet
[ ]
Hexhead Captive Bolt (replaces
Pentahead Bolt)
Breaker Mounting Provisions
[x]
[ ]
[x]
[ ]
Dial Type Thermometer
SS Nameplate
SS Tank Base & Cabinet Sides and Sill
[x]
[ ]
[ ]
Reverse positions of Drain Plug
& Valve
HV Warning Signs
SS Tank Base & Cabinet
Nitrogen Blanket with Bleeder
and Purge Valve
[ ]
[ ]
[ ]
2” Service Entrance in Sill
CT Space
PT Space
[ ]
[x]
[ ]
All Copper Windings
Dial Type Thermometer
Globe Type Upper Fill Valve
Color:
[x]
Standard Munsell No.
7GY3.29/1.5 Green
Testing:
[x]
ANSI Standard
[ ]
Certified Test
Results
Operating Conditions:
[ ]
[ ]
Other
[x]
[ ]
[ ]
[ ]
[ ]
[ ]
Liquid Level Gauge
Pressure/Vacuum Gauge
K-Factor Rated
K=9
K=20
K=30
Other ___________________
_______________________________
_______________________________
_______________________________
Maximum Elevation of Installation Site Above Sea Level:
Maximum Ambient Air Temperature:
Minimum Ambient Air Temperature:
Seismic:
feet
degrees f
degrees f
Download