PADMOUNTED CAPACITOR BANKS
(DEADFRONT and LIVEFRONT)
Models SCBD and SCBL, 5-35 kV.
2400 kVAR Max.
SCBD
FRONT VIEW EXPOSED
SCBD
REAR VIEW EXPOSED
SCBL
FRONT VIEW EXPOSED
SCBL
REAR VIEW EXPOSED
Application:
Powergrid Solutions (PSI) Padmount Capacitor banks are known to Customers in Commercial,
Industrial, and Utility markets as an effective way to improve power quality, increase reliability, improve power flow, and help maintain desired voltages within the operating tolerances of an underground power system. PSI capacitor banks also reduce reactive current and help extend the range of substation. Capacitor Banks are also used by large manufacturing and industrial companies to adjust for start-up load and can be very effective in helping to avoid costly utility penalties for power sag. PSI offers a variety of capacitor switching devices to ensure reliable capacitive load switching in our capacitor banks. PSI Padmount Capacitor Banks are available in medium voltage (5kV to 35kv) and features are completely customizable to the Customer’s needs including; Live-Front or Dead-Front design, Capacitor Fusing, Vacuum or Oil Switches,
Control Power Transformers options, Surge Arresters, Reactors, and Interlocking Systems.
PSI Padmount Capacitor banks are supplied in an outdoor weatherproof enclosure available in a variety of construction materials to meet the environmental needs.
© 2015 Powergrid Solutions Inc.
Catalog Version 2.1.1
To find a listing for your local Powergrid Solutions representative, log on to www.powergridsolutionsinc.com
5.1.1
CONSTRUCTION FEATURES
5
1
10
2
8
3
10
1. Lifting provisions with removable lifting plates and blind-tapped bolt holes. NFPA.
2. Stainless steel hinges, loose joint pin, allows doors to be removed in the open position.
10. Screened Tamper Proof Louvers
3. 3-point positive mechanism with recessed penta-bolt
4. Door Stay Arms
11. 200 amp bushing wells or 600 amp bushings
(Deadfront Only)
5. Cross Kinked Roof
6. “No-Drip” insulating compound on inside of roof
12. Cable Support Channels
13. Rear Compartment Barriers
7. Manufacture’s data plate, noncorrosive, stamped and attached to enclosure.
14. Full Length Continuous Ground Bus
15. Full Height Equipment Wall
© 2015 Powergrid Solutions Inc.
Catalog Version 2.1.1
To find a listing for your local Powergrid Solutions representative, log on to www.powergridsolutionsinc.com
5.1.2
CONSTRUCTION FEATURES
5
1
4
12
8
2
3
10
1. Lifting provisions with removable lifting plates and blind-tapped bolt holes. NFPA.
2. Stainless steel hinges, loose joint pin, allows doors to be removed in the open position.
10. Screened Tamper Proof Louvers
3. 3-point positive mechanism with recessed penta-bolt
4. Door Stay Arms
11. 200 amp bushing wells or 600 amp bushings
(Deadfront Only)
5. Cross Kinked Roof
6. “No-Drip” insulating compound on inside of roof
12. Cable Support Channels
13. Rear Compartment Barriers
7. Manufacture’s data plate, noncorrosive, stamped and attached to enclosure.
14. Full Length Continuous Ground Bus
15. Full Height Equipment Wall
© 2015 Powergrid Solutions Inc.
Catalog Version 2.1.1
To find a listing for your local Powergrid Solutions representative, log on to www.powergridsolutionsinc.com
5.1.3
PADMOUNTED CAPACITOR BANKS
(DEADFRONT and LIVEFRONT)
Models SCBL and SCBD, 5-35 kV.
2400 kVAR Max.
Catalog Number Selection Sheet.
To be used in conjunction with Factory Check Sheet.
MODEL
SCBD - DEADFRONT
SCBL - LIVEFRONT
P1 - PADMOUNT, LIVEFRONT, FIXED
P2 - PADMOUNT, DEADFRONT, FIXED
P3 - PADMOUNT, LIVEFRONT, SWITCHED
P4 - PADMOUNT, DEADFRONT, SWITCHED
1
3 05
15
25
35
KVAR RATING
STYLE
ENCLOSURE MATERIAL
SPECIAL
DESIGNATIONS
AL - ALUMINUM
GA - GALVANNEAL
MS - MILD STEEL
SS - STAINLESS
STEEL
SW - SWITCHED
FX - FIXED
ST - MULTI-STEPPED
CONNECTION
U - UNGROUNDED WYE
G - GROUNDED WYE
W - DOUBLE WYE
D - DELTA
PADMOUNT, 72” MAX., ENCLOSURE HEIGHT.
EXAMPLE: SCBL-P3-3151200USW-MS-XXXX
PADMOUNT, LIVEFRONT CAPACITOR BANK, 60” x 60” x 60”, 3 PHASE, 15 KV,
1200 KVAR, UNGROUNDED WYE CONNECTED, SWITCHED, CABINET IS
CONSTRUCTED OF MILD STEEL.
© 2015 Powergrid Solutions Inc.
Catalog Version 2.1.1
To find a listing for your local Powergrid Solutions representative, log on to www.powergridsolutionsinc.com
5.1.4
PADMOUNTED CAPACITOR BANKS
(DEADFRONT and LIVEFRONT)
Models SCBL and SCBD, 5-35 kV.
2400 kVAR Max.
Types P1, P2, P3 and P4.
Factory Check Sheet.
To be used in conjunction with Catalog Number Selection Sheet.
RATINGS:
Nominal System Voltage/
Maximum Design Voltage
Basic Insulation Level (BIL)
Continuous Current
______ / ______ kV
□
5 kV, 60 kV BIL
□
15 kV, 95 kV BIL
□
25 kV, 125 kV BIL
□
35 kV, 150 kV BIL
Other ___ kV, ___ kV BIL
□
200 amp or 600 amp
□
____ amp, Type:
□
Oil
□
Vacuum Main Switching Device
Fusing Rate: kVAR Rating (TOTAL)
□
____ amp, Type: ____, Voltage: ____ kV
□
____ amp, Type: ____, Voltage: ____ kV
__________ kVAR
ENCLOSURE:
Material:
□
□
□
A36 Mild Steel
A60 Galvanneal Steel
304 L Stainless Steel
5052-H32 Aluminum
Paint Finish:
□
Green. Munsell No., 7GY 3.29/1.5
□
Gray (ANSI 70). Munsell No., 8.3G 7.0/0.4
□
Gray (ANSI 61). Munsell No., 8.3G 6.10/0.54
□
Other: ___________________
3-Point Latch Type:
□
Penta-Head Bolt
□
Hex-Head Bolt
Bushing Wells and/or Bushings, (Model SCBD only):
□
□
Bushing Wells: 200 amp
Bushings: 600 amp
Equipment Compartment Barriers:
□
3/16”, Glass Reinforced Polyester, (standard).
1/4”, Clear Polycarbonate (Lexan). Replaces 3/16” Glass Reinforced Polyester Compartment Barriers.
□
Ground Switch. Group operated, external operating handle.
□
Equipment Compartment Barriers:
□
□
Ground Bails
Ground Bosses, 1/2-13 UNC. Qty: ____, Location: ____________.
□
Louvers for enclosure ventilation.
□
Insulation “No-Drip” Compound.
Applied to the inside surface of the enclosure roof to prevent condensation.
□
Base Undercoating.
Applied to the bottom 2” of the enclosure. (Not required for Stainless Steel enclosures.)
□
Control Options:____________________________________________________________________________________
□
Control Power Transformer: __________________________________________________________________________
Specials:
__________________________________________________________________________________________
© 2015 Powergrid Solutions Inc.
Catalog Version 2.1.1
To find a listing for your local Powergrid Solutions representative, log on to www.powergridsolutionsinc.com
5.1.5
PADMOUNTED CAPACITOR BANKS
(LIVEFRONT)
Model SCBL, Livefront, 5-35 kV.
Type P1-Fixed
FRONT VIEW EXPOSED
SIDE VIEW EXPOSED
REAR VIEW EXPOSED
CIRCUIT DIAGRAM STYLE
SCBL-P1
KV
15
25
35
For 5 kV applications, use 15 kV table.
For special configurations and sizes, consult factory.
H
60"
BASE PLAN
W
60"
© 2015 Powergrid Solutions Inc.
Catalog Version 2.1.1
To find a listing for your local Powergrid Solutions representative, log on to www.powergridsolutionsinc.com
D
60"
Consult Factory
Consult Factory
WGT
1050 LB
5.1.6
PADMOUNTED CAPACITOR BANKS
(DEADFRONT)
Model SCBD, Deadfront, 5-35 kV.
Type P2-Fixed
FRONT VIEW EXPOSED
SIDE VIEW EXPOSED
REAR VIEW EXPOSED
CIRCUIT DIAGRAM STYLE
SCBD-P2
KV
15
25
35
For 5 kV applications, use 15 kV table.
For special configurations and sizes, consult factory.
H
60"
BASE PLAN
W
60"
D
60"
Consult Factory
Consult Factory
WGT
1150 LB
© 2015 Powergrid Solutions Inc.
Catalog Version 2.1.1
To find a listing for your local Powergrid Solutions representative, log on to www.powergridsolutionsinc.com
5.1.7
PADMOUNTED CAPACITOR BANKS
(LIVEFRONT)
Model SCBL, Livefront, 5-35 kV.
Type P3-Switched
FRONT VIEW EXPOSED
SIDE VIEW EXPOSED
REAR VIEW EXPOSED
CIRCUIT DIAGRAM STYLE KV
15
SCBL-P3 25
35
For 5 kV applications, use 15 kV table.
For special configurations and sizes, consult factory.
H
60"
BASE PLAN
W
60"
D
60"
Consult Factory
Consult Factory
© 2015 Powergrid Solutions Inc.
Catalog Version 2.1.1
To find a listing for your local Powergrid Solutions representative, log on to www.powergridsolutionsinc.com
WGT
1175 LB
5.1.8
PADMOUNTED CAPACITOR BANKS
(DEADFRONT)
Model SCBD, Deadfront, 5-35 kV.
Type P4-Switched
FRONT VIEW EXPOSED
SIDE VIEW EXPOSED
REAR VIEW EXPOSED
BASE PLAN
CIRCUIT DIAGRAM STYLE KV
15
SCBD-P4 25
35
For 5 kV applications, use 15 kV table.
For special configurations and sizes, consult factory.
H
60"
W
60"
D
60"
Consult Factory
Consult Factory
© 2015 Powergrid Solutions Inc.
Catalog Version 2.1.1
To find a listing for your local Powergrid Solutions representative, log on to www.powergridsolutionsinc.com
WGT
1275 LB
5.1.9
METAL-ENCLOSED CAPACITOR BANKS
Model SCBM, 5-35 kV.
Types M1 and M2.
Externally Fused Capacitors.
FRONT VIEW SIDE VIEW
Application:
Powergrid Solutions (PSI) Metal-Enclosed Capacitor banks are known to Customers in Commercial, Industrial, and Utility markets as an effective way to improve power quality, increase reliability, improve power flow, and help maintain desired voltages within the operating tolerances of an underground power system. PSI capacitor banks also reduce reactive current and help extend the range of substation. Capacitor Banks are also used by large manufacturing and industrial companies to adjust for start-up load and can be very effective in helping to avoid costly utility penalties for power sag. PSI offers a variety of capacitor switching devices to ensure reliable capacitive load switching in our capacitor banks. PSI Metal-Enclosed Capacitor Banks are available in medium voltage (5kV to 35kv) and features are completely customizable to the customer’s needs including; Capacitor Fusing, Vacuum or Oil Switches, Control
Power Transformers options, Surge Arresters, Reactors, and Interlocking Systems. PSI Metal-
Enclosed Capacitor banks are supplied in either an weatherproof outdoor or indoor enclosure available in a variety of construction materials to meet the customer and environmental needs.
© 2015 Powergrid Solutions Inc.
Catalog Version 2.1.1
To find a listing for your local Powergrid Solutions representative, log on to www.powergridsolutionsinc.com
5.2.1
CONSTRUCTION FEATURES
10
1
5
7
2 3
1. Lifting provisions with removable lifting plates and blind-tapped bolt holes.
8. Phase Identification Labels
9. Screened Tamper Proof Louvers
2. Stainless steel hinges, loose joint pin, allows doors to be removed in the open position. 10. Switchblade viewing window
3. 3-Point positive rotary latch mechanism
11. Split full length, inner safety screen door
4. Door Stay Arms 12. 3/16” GPO-3 Glass Polyester barrier
5. Sloped Roof (Not standard on indoor gear line-ups) 13. Rear Compartment Barriers
6. Neoprene Gasketed Doors 14. Full Length Continuous Ground Bus
NFPA.
© 2015 Powergrid Solutions Inc.
Catalog Version 2.1.1
To find a listing for your local Powergrid Solutions representative, log on to www.powergridsolutionsinc.com
5.2.2
CONSTRUCTION FEATURES
12
6
11
5
3
7
15
10
1. Lifting provisions with removable lifting plates and blind-tapped bolt holes.
8. Phase Identification Labels
9. Screened Tamper Proof Louvers
2. Stainless steel hinges, loose joint pin, allows doors to be removed in the open position. 10. Switchblade viewing window
3. 3-Point positive rotary latch mechanism
11. Split full length, inner safety screen door
4. Door Stay Arms 12. 3/16” GPO-3 Glass Polyester barrier
5. Sloped Roof (Not standard on indoor gear line-ups) 13. Rear Compartment Barriers
6. Neoprene Gasketed Doors 14. Full Length Continuous Ground Bus
NFPA.
© 2015 Powergrid Solutions Inc.
Catalog Version 2.1.1
To find a listing for your local Powergrid Solutions representative, log on to www.powergridsolutionsinc.com
5.2.3
METAL-ENCLOSED CAPACITOR BANKS
Model SCBM, 5-35 kV.
Types M1 and M2.
Externally Fused Capacitors.
Catalog Number Selection Sheet.
To be used in conjunction with Factory Check Sheet.
S C B M
MODEL
TYPE
1
3
M1 - METAL-ENCLOSED, SINGLE-SIDE ACCESS
M2 - METAL-ENCLOSED, DUAL-SIDE ACCESS
KVAR RATING
05
15
25
35
STYLE
ENCLOSURE MATERIAL
SPECIAL
DESIGNATIONS
AL - ALUMINUM
GA - GALVANNEAL
MS - MILD STEEL
SS - STAINLESS
STEEL
SW - SWITCHED
FX - FIXED
ST - MULTI-STEPPED
CONNECTION
U - UNGROUNDED WYE
G - GROUNDED WYE
W - DOUBLE WYE
D - DELTA
EXAMPLE: SCBM-M1-3152400GSW-GA-XXXX
METAL-ENCLOSED, CAPACITOR BANK, 3 PHASE, 15 KV, 2400 KVAR, TYPE M1,
GROUNDED WYE CONNECTED, SWITCHED, CABINET IS CONSTRUCTED OF
GALVANNEAL STEEL.
© 2015 Powergrid Solutions Inc.
Catalog Version 2.1.1
To find a listing for your local Powergrid Solutions representative, log on to www.powergridsolutionsinc.com
5.2.4
METAL-ENCLOSED CAPACITOR BANKS
Model SCBM, 5-35 kV.
Types M1 and M2.
Externally Fused Capacitors.
Factory Check Sheet.
To be used in conjunction with Catalog Number Selection Sheet.
RATINGS:
Nominal System Voltage/
Maximum Design Voltage
Basic Insulation Level (BIL)
Continuous Current
Main Disconnect Switching Device
______ / ______ kV
□
5 kV, 60 kV BIL
□
15 kV, 95 kV BIL
25 kV, 125 kV BIL
□
35 kV, 150 kV BIL
□
Other ___ kV, ___ kV BIL
____ amp
□
____ amp, ____ kV, ____ kV BIL
□
____ amp, ____ kV, ____ kV BIL Capacitor Switching Device
Fusing Rate:
□
____ amp, Type: ____, Voltage: ____ kV
□
____ amp, Type: ____, Voltage: ____ kV
__________ kVAR kVAR Rating (TOTAL)
ENCLOSURE:
Enclosure Type:
□
Indoor
Outdoor
Material:
□
A36 Mild Steel
□
A60 Galvanneal Steel
304 L Stainless Steel
□
5052-H32 Aluminum
Paint Finish:
□
Green. Munsell No., 7GY 3.29/1.5
□
Gray (ANSI 70). Munsell No., 8.3G 7.0/0.4
□
Gray (ANSI 61). Munsell No., 8.3G 6.10/0.54
Other: ___________________
3-Point Latch Type:
□
Penta-Head Bolt
□
Hex-Head Bolt
Padlocking Handle
□
Forced Air Ventilation. (Based on heat-rise calculations).
□
Strip Heaters.
□
Ground Options:
□
Ground Bails
Ground Bosses, 1/2-13 UNC. Qty: ____, Location: ____________.
□
Insulation “No-Drip” Compound.
Applied to the inside surface of the enclosure roof to prevent condensation.
□
Base Undercoating. Applied to the bottom 2” of the enclosure. (Not required for Stainless Steel enclosures.)
(Factory Check Sheet continued on page 5.2.6)
© 2015 Powergrid Solutions Inc.
Catalog Version 2.1.1
To find a listing for your local Powergrid Solutions representative, log on to www.powergridsolutionsinc.com
5.2.5
METAL-ENCLOSED CAPACITOR BANKS
Model SCBM, 5-35 kV.
Types M1 and M2.
Externally Fused Capacitors.
Factory Check Sheet (continued).
Main Disconnect Section:
□
Disconnecting Switches: ____ amp, ____ kV, Type: ____, Manufacturer: ________.
600 amperes, Non-loadbreak Elbow Terminators.
□
Main Fusing: ____ amp, ____ kV, Type: ____, Manufacturer: ________.
□
Surge Arresters: ____ kV, Type: ____, Manufacturer: ________.
Capacitor Switching Section:
□
Vacuum Circuit Breaker, (special sizing required, consult factory): ____ amp, ____ kV, Type: ____, Manufacturer: ________.
Vacuum Contactor, (5 kV applications max): ____ amp, ____ kV, Type: ____, Manufacturer: ________.
□
Vacuum Switch: ____ amp, ____ kV, Type: ____, Manufacturer: ________.
□
Oil Switch: ____ amp, ____ kV, Type: ____, Manufacturer: ________.
Other: ____ amp, ____ kV, Type: ____, Manufacturer: ________.
Reactors:
□
Air Core: ____ uH, ____ amp, Manufacturer (if other than Powergrid Solutions): ________.
Iron Core: ____ uH, ____ amp, Manufacturer: ________. (Special sizing may be required, consult factory).
Capacitor Section.
Section Type:
□
Internally Fused Capacitors. (Consult Factory)
□
Externally Fused Capacitors.
1 Capacitor per phase, (standard 15 kV size: 102 H x 60 W x 60 D).
□
2 Capacitors per phase, (standard 15 kV size: 102 H x 80 W x 60 D).
Note: When selecting Capacitor section type for Type M2 Capacitor Banks, the section type must be the same front and rear alignment.
Capacitors: ____ kVAR, ____ kV, ____ BIL, Manufacturer: ________.
Capacitor Fusing: ____ amp, ____ kV, Type: ____, Manufacturer: ________.
□
Ground Switches:
Control Power Transformer:
□
Specials:
____________________________________________________________________________________________
____________________________________________________________________________________________
For 5 kV applications, use 15 kV sizing.
For 25 kV and 35 kV sizes, consult factory.
For internally fused capacitor designs, please consult factory.
For special configurations and sizes, consult factory.
© 2015 Powergrid Solutions Inc.
Catalog Version 2.1.1
To find a listing for your local Powergrid Solutions representative, log on to www.powergridsolutionsinc.com
5.2.6
METAL-ENCLOSED CAPACITOR BANKS
Model SCBM, 5-35 kV.
Type M1.
Externally Fused Capacitors.
FRONT VIEW SIDE VIEW
FRONT VIEW EXPOSED
LINE DIAGRAM
PLAN VIEW
© 2015 Powergrid Solutions Inc.
Catalog Version 2.1.1
To find a listing for your local Powergrid Solutions representative, log on to www.powergridsolutionsinc.com
5.2.7
METAL-ENCLOSED CAPACITOR BANKS
Model SCBM, 5-35 kV.
Type M1.
Externally Fused Capacitors.
MAIN DISCONNECT SWITCH
SIDE VIEW EXPOSED
CAPACITOR SWITCH
SIDE VIEW EXPOSED
CAPACITOR SECTION
SIDE VIEW EXPOSED
The Capacitor Bank illustrations on pages 5.2.7 and 5.2.8 are shown as examples. This unit illustrated includes the following:
Main Disconnect Section / 600 AMP, Group operated switch.
Capacitor Switching Section / Vacuum Switch, Powergrid Solutions Current-Limiting Reactors,
Powergrid Solutions 4 Pole Ground Capacitor Switch.
Capacitor Section, 18 Can Rack: Capacitor Fuses and Capacitors.
Refer to Selection Guide for specific applications.
© 2015 Powergrid Solutions Inc.
Catalog Version 2.1.1
To find a listing for your local Powergrid Solutions representative, log on to www.powergridsolutionsinc.com
5.2.8
METAL-ENCLOSED CAPACITOR BANKS
Model SCBM, 5-35 kV.
Type M2.
Externally Fused Capacitors.
FRONT VIEW SIDE VIEW
FRONT VIEW EXPOSED
LINE DIAGRAM
PLAN VIEW
© 2015 Powergrid Solutions Inc.
Catalog Version 2.1.1
To find a listing for your local Powergrid Solutions representative, log on to www.powergridsolutionsinc.com
5.2.9
METAL-ENCLOSED CAPACITOR BANKS
Model SCBM, 5-35 kV.
Type M2.
Externally Fused Capacitors.
MAIN DISCONNECT SWITCH
SIDE VIEW EXPOSED
CAPACITOR SWITCH
SIDE VIEW EXPOSED
CAPACITOR SECTION
SIDE VIEW EXPOSED
The Capacitor Bank illustrations on page 5.2.9 and 5.2.10 are shown as examples. This unit illustrated includes the following:
Main Disconnect Section: 1– 600 AMP, group operated switch.
Front Capacitor Switching Section: 1 - Vacuum Switch, 3 - Powergrid Solutions Current-Limiting Reactors, 1 - Powergrid Solutions 4 Pole Ground Switch.
Front Capacitor Section, 18 Can Rack: Capacitor Fuses and Capacitors.
Rear Capacitor Switching Section: 1 - Vacuum Switch, 3 - Powergrid Solutions Current-Limiting Reactors, 1 - Powergrid Solutions 4 Pole Ground Switch.
Rear Capacitor Section, 18 Can Rack: Capacitor Fuses and Capacitors.
Refer to Selection Guide for specific applications.
© 2015 Powergrid Solutions Inc.
Catalog Version 2.1.1
To find a listing for your local Powergrid Solutions representative, log on to www.powergridsolutionsinc.com
5.2.10
MULTI-STEP CAPACITOR BANKS
Model SCBM, 5-35 kV.
Types S1 and S2.
Externally Fused Capacitors.
FRONT VIEW
Application:
Powergrid Solutions (PSI) Multi-Step Capacitor banks are known to Customers in Commercial,
Industrial, and Utility markets as an effective way to improve power quality, increase reliability, improve power flow, and help maintain desired voltages within the operating tolerances of an underground power system. PSI capacitor banks also reduce reactive current and help extend the range of substation. Capacitor Banks are also used by large manufacturing and industrial companies to adjust for start-up load and can be very effective in helping to avoid costly utility penalties for power sag. PSI offers a variety of capacitor switching devices to ensure reliable capacitive load switching in our capacitor banks. PSI Multi-Step Capacitor Banks are available in medium voltage (5kV to 35kv) and features are completely customizable to the Customer’s needs including; Live-Front or Dead-Front design, Capacitor Fusing, Vacuum or Oil Switches,
Control Power Transformers options, Surge Arresters, Reactors, and Interlocking Systems.
PSI Multi-Step Capacitor banks are supplied in an outdoor weatherproof enclosure available in a variety of construction materials to meet the environmental needs.
© 2015 Powergrid Solutions Inc.
Catalog Version 2.1.1
To find a listing for your local Powergrid Solutions representative, log on to www.powergridsolutionsinc.com
5.3.1
MULTI-STEP CAPACITOR BANKS
Model SCBM, 5-35 kV.
Types S1 and S2.
Externally Fused Capacitors.
Catalog Number Selection Sheet.
To be used in conjunction with Factory Check Sheet.
S C B M
MODEL
TYPE
1
3
S1 - METAL-ENCLOSED, SINGLE-SIDE ACCESS, MULTI-STEP
S2 - METAL-ENCLOSED, DUAL-SIDE ACCESS, MULTI-STEP
05
15
25
35
KVAR RATING
STYLE
ENCLOSURE MATERIAL
SPECIAL
DESIGNATIONS
AL - ALUMINUM
GA - GALVANNEAL
MS - MILD STEEL
SS - STAINLESS
STEEL
SW - SWITCHED
FX - FIXED
ST - MULTI-STEPPED
CONNECTION
U - UNGROUNDED WYE
G - GROUNDED WYE
W - DOUBLE WYE
D - DELTA
EXAMPLE: SCBM-S2-3151800GSW-MS-XXXX
METAL-ENCLOSED, CAPACITOR BANK, 3 PHASE, 15 KV, 1800 KVAR, TYPE S2,
GROUNDED WYE CONNECTED, SWITCHED, CABINET IS CONSTRUCTED OF
MILD STEEL.
© 2015 Powergrid Solutions Inc.
Catalog Version 2.1.1
To find a listing for your local Powergrid Solutions representative, log on to www.powergridsolutionsinc.com
5.3.2
MULTI-STEP CAPACITOR BANKS
Model SCBM, 5-35 kV.
Types S1 and S2.
Externally Fused Capacitors.
Factory Check Sheet.
To be used in conjunction with Catalog Number Selection Sheet.
RATINGS:
Nominal System Voltage/
Maximum Design Voltage
Basic Insulation Level (BIL)
Continuous Current
Main Disconnect Switching Device
Capacitor Switching Device
Fusing Rate:
______ / ______ kV
□
5 kV, 60 kV BIL
15 kV, 95 kV BIL
□
25 kV, 125 kV BIL
□
35 kV, 150 kV BIL
□
Other ___ kV, ___ kV BIL
□
____ amp
□
____ amp, ____ kV, ____ kV BIL
□
____ amp, ____ kV, ____ kV BIL kVAR Rating (TOTAL)
□
____ amp, Type: ____, Voltage: ____ kV
□
____ amp, Type: ____, Voltage: ____ kV
__________ kVAR
ENCLOSURE:
Enclosure Type:
□
Indoor
Outdoor
Material:
□
A36 Mild Steel
□
A60 Galvanneal Steel
304 L Stainless Steel
□
5052-H32 Aluminum
Paint Finish:
□
Green. Munsell No., 7GY 3.29/1.5
□
Gray (ANSI 70). Munsell No., 8.3G 7.0/0.4
Gray (ANSI 61). Munsell No., 8.3G 6.10/0.54
□
Other: ___________________
3-Point Latch Type:
□
Penta-Head Bolt
□
Hex-Head Bolt
□
Padlocking Handle
□
Forced Air Ventilation. (Based on heat-rise calculations).
□
Strip Heaters.
□
Ground Options:
□
Ground Bails
Ground Bosses, 1/2-13 UNC. Qty: ____, Location: ____________.
□
Insulation “No-Drip” Compound.
Applied to the inside surface of the enclosure roof to prevent condensation.
□
Base Undercoating. Applied to the bottom 2” of the enclosure. (Not required for Stainless Steel enclosures.)
(Factory Check Sheet continued on page 5.3.4)
© 2015 Powergrid Solutions Inc.
Catalog Version 2.1.1
To find a listing for your local Powergrid Solutions representative, log on to www.powergridsolutionsinc.com
5.3.3
MULTI-STEP CAPACITOR BANKS
Model SCBM, 5-35 kV.
Types S1 and S2.
Externally Fused Capacitors.
Factory Check Sheet (continued).
Main Disconnect Section:
□
Disconnecting Switches: ____ amp, ____ kV, Type: ____, Manufacturer: ________.
600 amperes, Non-loadbreak Elbow Terminators.
□
Main Fusing: ____ amp, ____ kV, Type: ____, Manufacturer: ________.
□
Surge Arresters: ____ kV, Type: ____, Manufacturer: ________.
Capacitor Switching Section:
Selection Type:
□
1 Capacitor per phase, (standard 15 kV size: 102 H x 60 W x 60 D).
2 Capacitors per phase, (standard 15 kV size: 102 H x 80 W x 60 D).
Note:
When selecting Capacitor section type for Type S2 Capacitor Banks, the section type must be the same front and rear to maitain front and rear alignment.
Selection Type:
□
Single pole vacuum switches, 200 amp on 15 kV, 95 kV BIL systems or 200 amp on 25 kV, 125 kV BIL applied on grounded
wye systems.
□
Three pole vacuum switch, 200 amp on 15 kV, 95 kV BIL systems or 200 amp on 25 kV, 125 kV BIL applied on grounded
wye systems.
□
Single pole oil switches, 200 amp on 15 kV, 95 kV BIL; or 25 kV, 125 kV BIL systems; or 35 kV, 150 kV BIL applied
on grounded wye systems.
□
Three pole oil switches, 200 amp on 15 kV, 95 kV BIL; or 25 kV, 125 kV BIL systems; or 35 kV, 150 kV BIL applied
on grounded wye systems.
□
Vacuum contactor, on 5 kV, 60 kV BIL systems.
Reactors:
□
Other: ____ amp, ____ kV, Type: ____, Manufacturer: ________.
□
Air Core: ____ uH, ____ amp, Manufacturer (if other than Powergrid Solutions): ________.
□
Iron Core: ____ uH, ____ amp, Manufacturer: ________. (Special sizing may be required, consult factory).
□
Ground Switches:
□
Control Power Transformer:
□
Specials:
____________________________________________________________________________________________
____________________________________________________________________________________________
____________________________________________________________________________________________
For 5 kV applications, use 15 kV sizing.
For 25 kV and 35 kV sizes, consult factory.
For special configurations and sizes, consult factory.
© 2015 Powergrid Solutions Inc.
Catalog Version 2.1.1
To find a listing for your local Powergrid Solutions representative, log on to www.powergridsolutionsinc.com
5.3.4
MULTI-STEP CAPACITOR BANKS
Model SCBM, 5-35 kV.
Type S1.
Externally Fused Capacitors.
FRONT VIEW SIDE VIEW
FRONT VIEW EXPOSED
PLAN VIEW
© 2015 Powergrid Solutions Inc.
Catalog Version 2.1.1
To find a listing for your local Powergrid Solutions representative, log on to www.powergridsolutionsinc.com
5.3.5
MULTI-STEP CAPACITOR BANKS
Model SCBM, 5-35 kV.
Type S1.
Externally Fused Capacitors.
MAIN DISCONNECT SWITCH
SIDE VIEW EXPOSED
CAPACITOR SECTION
SIDE VIEW EXPOSED
LINE DIAGRAM
The Capacitor Bank illustrations on pages 5.3.5 and 5.3.6 are shown as examples. This illustration includes the following:
Main Disconnect Section: 1 - 600 AMP, Group operated switch.
Capacitor Section: 2 Capacitors per phase; 3 - Vacuum Switches, 3 - Powergrid Solutions Current-
Limiting Reactors, 1 - Powergrid Solutions 4 Pole Ground Switch, and Capacitor Fuses.
Capacitor Section: 1 Capacitor per phase; 3 - Vacuum Switches, Powergrid Solutions Current-
Limiting Reactors, 1 - Powergrid Solutions 4 Pole Ground Switch, and Capacitor Fuses.
For specific applications, refer to the Selection Guide.
© 2015 Powergrid Solutions Inc.
Catalog Version 2.1.1
To find a listing for your local Powergrid Solutions representative, log on to www.powergridsolutionsinc.com
5.3.6
MULTI-STEP CAPACITOR BANKS
Model SCBM, 5-35 kV.
Type S2.
Externally Fused Capacitors.
FRONT VIEW
FRONT VIEW EXPOSED
SIDE VIEW
PLAN VIEW
© 2015 Powergrid Solutions Inc.
Catalog Version 2.1.1
To find a listing for your local Powergrid Solutions representative, log on to www.powergridsolutionsinc.com
5.3.7
MULTI-STEP CAPACITOR BANKS
Model SCBM, 5-35 kV.
Type S2.
Externally Fused Capacitors.
MAIN DISCONNECT SWITCH
SIDE VIEW EXPOSED
CAPACITOR SECTION
SIDE VIEW EXPOSED
LINE DIAGRAM
The Capacitor Bank illustrations on pages 5.3.7 and 5.3.8 are shown as examples. This illustration includes the following:
Main Disconnect Section: 1 - 600 AMP, Group operated switch.
Capacitor Section: 2 Capacitors per phase; 3 - Vacuum Switches, 3 - Powergrid Solutions Current-
Limiting Reactors, 1 - Powergrid Solutions 4 Pole Ground Switch, and Capacitor Fuses.
Capacitor Section: 1 Capacitor per phase; 3 - Vacuum Switches, 3 - Powergrid Solutions Current-
Limiting Reactors, 1 - Powergrid Solutions 4 Pole Ground Switch, and Capacitor Fuses.
For specific applications, refer to the Selection Guide.
© 2015 Powergrid Solutions Inc.
Catalog Version 2.1.1
To find a listing for your local Powergrid Solutions representative, log on to www.powergridsolutionsinc.com
5.3.8