Circuit Breakers

advertisement
02-Circuit Breakers
4/16/09
12:27 PM
Page 2-8
Circuit Breakers
Arc-Fault Circuit Interrupters (AFCI)
• UL Listed
• HACR & SWD Rated
• Standard 1 inch per pole format with plug-in design
2
Combination Type AFCI 햳
AFCI’s detect arcing faults (an unintentional arcing condition in a circuit) that standard circuit
breakers are unable to detect. The Combination Type AFCI detects all three possible types of
arc fault: line-to-ground, line-to-neutral, and series. The device is intended to mitigate the
effects of arcing faults by functioning to de-energize the circuit when an arc-fault is detected.
CIRCUIT BREAKERS
10,000 A IR
Breaker
Type
MP-AT/
MP-HAT
1-Pole 120V AC
MP-AT/
MP-HAT
2-Pole 120/240V AC
Ampere
Rating
22,000 A IR
Catalog
Number
List
Price $
Catalog
Number
List
Price $
15
MP115AFC햲
300.00
MP115AFCH■햲
606.00
20
MP120AFC햲
300.00
MP120AFCH■햲
606.00
15
MP215AFC햲
600.00
MP215AFCH■햲
1212.00
20
햲
600.00
MP220AFCH■햲
1212.00
MP220AFC
1-Pole Combination
Type AFCI
2-Pole Combination
Type AFCI
Branch-Feeder AFCI
AFCI’s detect arcing faults (an unintentional arcing condition in a circuit) that standard circuit
breakers are unable to detect. The Branch-Feeder AFCI detects line-to-ground and line-to-neutral arcs. The device is intended to mitigate the effects of arcing faults by functioning to deenergize the circuit when an arc-fault is detected.
10,000 A IR
Breaker
Type
MP-AT/
MP-HAT
1-Pole 120V AC
MP-AT/
MP-HAT
2-Pole 120/240V AC
Ampere
Rating
22,000 A IR
Catalog
Number
List
Price $
Catalog
Number
List
Price $
15
MP115AF햲
270.00
MP115AFH■햲
545.00
20
MP120AF햲
270.00
MP120AFH■햲
545.00
15
MP215AF
463.00
MP215AFH■
698.00
20
MP220AF
463.00
MP220AFH■
698.00
1-Pole Branch
Feeder AFCI
AFCI Accessories
Description
Catalog Number
List Price $
Padlocking Device for 1" & Twin Breakers
ECPLD1
10.70
Padlocking Device for 2" & Quad Breakers
ECPLD2
10.80
Handle Blocking Device for 1/2" Circuit Breakers
ECBX231M
10.30
■ Built to order. Allow 2–3 weeks for delivery.
햲
UL Listed as SWD (Switching Duty) Rated, suitable for
120V AC Fluorescent Lighting.
Discount Schedule RESI
햳
White line neutral (pigtail) must be connected to the
panel neutral for the device to function.
2008-2009 Electrical Distribution Products
2-8
Siemens / Speedfax
Original Folio # new page
Sieme
Circuit Breakers
Ground-Fault Circuit Interrupters (GFCI)
• UL Listed and CSA Certified
• HACR Rated
• Standard 1 inch per pole format with plug-in design
Ground-Fault Circuit Interrupters (Class A - 5mA)햳
Ground-fault circuit interrupters (GFCI) provide Class A ground fault protection. A GFCI is a
device intended for personnel protection and will de-energize the circuit when a fault current to
ground is 6 milliamperes or more.
2
1-Pole
120V AC
MP-GT/
MP-HGT
2-Pole
120/240V AC
15
20
25
30
MP115 GF햲
MP120 GF햲
MP125 GF■
MP130 GF
270.00
270.00
270.00
270.00
MP115GFH ■ 햲
MP120GFH ■ 햲
—
MP130GFH■
545.00
545.00
15
20
30
40
50
60
MP215 GF
MP220 GF
MP230 GF
MP240 GF
MP250 GF
MP260 GF
483.00
483.00
483.00
483.00
483.00
483.00
MP215GFH■
MP220GFH■
MP230GFH■
MP240GFH■
MP250GFH■
MP260GFH■
717.00
717.00
717.00
717.00
717.00
717.00
CIRCUIT BREAKERS
MP-GT/
MP-HGT
545.00
1-Pole GFCI
2-Pole GFCI
햳
Ground Fault Equipment Protection (30mA)
Type EQF circuit breakers provide protection of equipment from damaging line-to-ground fault
currents by de-energizing the circuit for all ungrounded conductors of the faulted circuit.
MP-ET/
MP-HET
1-Pole
120V AC
MP-ET/
MP-HET
2-Pole
120/240V AC
15
20
30
MP115 EG햲
MP120 EG햲
MP130 EG
492.00
492.00
492.00
MP115EGH ■ 햲
MP120EGH ■ 햲
MP130EGH ■
15
20
30
40
50
60
MP215 EG
MP220 EG
MP230 EG
MP240 EG
MP250 EG
MP260 EG■
651.00
651.00
651.00
651.00
651.00
651.00
MP215EGH■
MP220EGH■
MP230EGH■
MP240EGH■
MP250EGH■
MP260EGH■
808.00
808.00
808.00
1074.00
1074.00
1074.00
1074.00
1074.00
1074.00
AFCI and GFCI Accessories
Description
Catalog Number
List Price $
Padlocking Device for 1" & Twin Breakers
ECPLD1
10.70
Padlocking Device for 2" & Quad Breakers
ECPLD2
10.80
Handle Blocking Device for 1/2" Circuit Breakers
ECBX231M
10.30
■ Built to order. Allow 2–3 weeks for delivery.
햲
UL Listed as SWD (Switching Duty) Rated, suitable for
120V AC Fluorescent Lighting.
햳
Wiring Diagrams
White line neutral (pigtail) must be connected to the
panel neutral for the device to function.
2008-2009 Electrical Distribution Products
Discount Schedule RESI
2-9
Related documents
Download