RF100 Series
Installation Sheet
08/02
RegFlo™ RF100 Series Battery Module
Installation
TB1 TERMINATION
STRIP (REMOVED)
JUMPER (SHOWN
IN OFF POSITION)
Figure 1. RF100 Series Battery Module
Principle of Operation
This new and improved battery module design extends battery life and ensures sufficient voltage at low temperatures. It cannot be used in conjunction with external power and is not rechargeable. Table 1 shows the life expectancy of the battery in months for the different configurations. The Average Current Draw shown in Table 2 can be
used to size external power systems or batteries.
Installation
1. To activate the battery power output, remove the jumper from the battery module and replace it over the center
pin and pin marked I (on position). The pin marked 0 (off position) will not be covered by the jumper. The battery
should be stored in the off position to maintain life expectancy.
2. Remove the TB2 External Power Connector and TB1 I/O Termination Strip.
3. Remove the four screws and washers that hold the Electronics Module in place.
D103072X012
4. Plug the battery into the electronics module and replace the four screws and washers to hold the assembly
in place.
www.FISHERregulators.com
RF100 Series
Table 1. Battery Life Expectancy
MONTHS OF BATTERY LIFE(1)
COMMUNICATIONS MODE
Sample Interval
10 seco n d s
30 seco n d s
1 minute
2 minutes
5 minutes
Consumption(2)
10 minutes
30 minutes
9
22
35
49
58
74
81
Scheduled Auto Answer (30m)(3)
8
17
24
30
33
38
39
Scheduled Auto Answer (10m * 8hr)(4)
7
14
19
23
24
27
28
Scheduled Auto Answer (Full Time)(5)
2
3
3
3
3
3
3
B a se
Power up on Ring
Modem(6)
8
19
27
35
39
46
49
Only RS232 Card(6)
8
20
30
40
45
54
58
Only RS485 Card(6)
8
17
24
29
32
37
38
Powered Modem and RS485 card(6)
7
14
19
23
25
27
28
1. Assumes usable batery capacity is 80 percent (allows for operating temperature and shelf life).
2. Base Consumption assumes no Host communications and one connection (15 minute) with local RegLink once per week.
3. Scheduled Auto Answer (30m) assumes that modem is active for 30 minutes per day and has a 5 minute phone connection per day.
4. Schedules Auto Answer (10m * 8 hr) assumes that the modem is active for 80 minutes per day and has a 5 minute phone connection per day.
5. Scheduled Auto Answer (Full Time) assumes that the modem is active all of the time to receive a communication.
6. Assumes a 5 minute connection per day.
Table 2. Average Current Draw
AVERAGE CURRENT DRAW(1)
COMMUNICATIONS MODE
Sample Interval
10 seco n d s
30 seco n d s
1 minute
2 minutes
5 minutes
10 minutes
30 minutes
Base Consumption(2)
1.426
0.659
0.468
0.372
0.340
0.295
0.282
Scheduled Auto Answer (30m)(3)
1.621
0.854
0.663
0.567
0.535
0.490
0.477
Scheduled Auto Answer (10m * 8hr)(4)
1.829
1.062
0.871
0.775
0.743
0.698
0.685
Scheduled Auto Answer (Full Time)(5)
7.226
6.459
6.268
6.172
6.140
6.095
6.082
Power up on Ring Modem(6)
1.530
0.763
0.572
0.476
0.444
0.399
0.386
Only RS232 Card(6)
1.528
0.761
0.570
0.474
0.442
0.397
0.384
Only RS485 Card(6)
1.754
0.987
0.796
0.700
0.668
0.623
0.610
Powered Modem and RS485 card(6)
1.834
1.067
0.876
0.780
0.748
0.703
0.690
1. Average Current Draw when device is externally powered.
2. Base Consumption assumes no Host communications and one connection (15 minute) with local RegLink once per week.
3. Scheduled Auto Answer (30m) assumes that modem is active for 30 minutes per day and has a 5 minute phone connection per day.
4. Schedules Auto Answer (10m * 8 hr) assumes that the modem is active for 80 minutes per day and has a 5 minute phone connection per day.
5. Scheduled Auto Answer (Full Time) assumes that the modem is active all of the time to receive a communication.
6. Assumes a 5 minute connection per day.
Fisher is a mark owned by Fisher Controls International, Inc., a business of Emerson Process Management. The Emerson logo is a trademark and service mark of Emerson Electric Co. All other marks are the
property of their respective owners.
The contents of this publication are presented for informational purposes only, and while every effort has been made to ensure their accuracy, they are not to be construed as warranties or guarantees, express
or implied, regarding the products or services described herein or their use or applicability. We reserve the right to modify or improve the designs or specifications of such products at any time without notice.
Fisher does not assume responsibility for the selection, use or maintenance of any product. Responsibility for proper selection, use and maintenance of any Fisher product remains solely with the purchaser.
For information, contact Fisher:
Marshalltown, Iowa 50158 USA
McKinney, Texas 75070 USA
28320 Gallardon, France
40013 Castel Maggiore (BO), Italy
Sao Paulo 05424 Brazil
Singapore 128461
©Fisher Controls International, Inc., 2002; All Rights Reserved