app fotovoltaici 2010 GB:Contatori 08/10/10 12:56 Pagina 1 app fotovoltaici 2010 GB:Contatori 08/10/10 12:56 Pagina 2 ® srl was established in Milan, in 1983, with the intention of design and production of electrical measurement and control equipment for the electric and automation industries, accommodating all standard electrical parameters. In doing took full advantage of latest technologies to produce modern high quality products taking into consideration the requirements of each potential industry in relation to their installation and use in the field. It has always been Revalcos’ strategy to see that global quality is maintained to the high standard incorporated in the manufacture as managed by definite quality procedures supported by the Quality Assurance Officers. The procedures that that have been adopted and the organisation to apply them, has been approved by the CSQ (Certification of Quality Systems) and has certified that the quality of the systems conform to the standards of UNI EN ISO 9001/2000. The CISQ Federation (Italian Certification of Quality Systems), of which CSQ is an integral branch has collaborated with the certification offices of IQNet (International Quality Systems Assessment and Certification Network), to gain a mutual agreement in the recognition of the certifications. As a result of this agreement can claim the IQNet certification and international validity of CSQ certification. This prestigious recognition confirms the quality standard of products. The range of products cover a full market range of Analogue and Digital instruments, ranging from standard Ammeters and Voltmeters through to sophisticated Electronic Analysers and Multifunction Metering Systems, for both flush Panel, Switchboard mounting and also for Din Rail mounting. These are supported by a wide range of associated equipment such as Current and Voltage Transformers and Shunts, Measurement Transducers, Control Relay and Surge Protection. Other products available includes Time and Pulse Counters, Switches, Audio Alarms and Buzzers, Timers, Power Supplies, and Earth Leakage measurement equipment. Safety Transformers for general use and Bell Transformers Din Rail Modular versions being the latest additions to the very comprehensive range of products available from . Visit our Web Site www.revalco.it for further details. app fotovoltaici 2010 GB:Contatori 08/10/10 12:56 Pagina 3 ANALOGUE INSTRUMENTS VOLTMETERS, MOVING COIL INSTRUMENTS FOR DIRECT CURRENT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 AMMETERS, MOVING COIL INSTRUMENTS FOR DIRECT CURRENT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 HOUR METERS HOUR METERS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6 DIGITAL INSTRUMENTS VOLTMETERS 800V DC + option RS485 + option 4/20mA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 AMMETERS 5A (1A) or 60mV with “I max demand” + option RS485 + option 4/20mA . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 PROGRAMMINGS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 MULTIFUNCTION METERS LCD - 4 DIN MODULES D.C. VERSION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 kWh-METERS FOR DIRECT CURRENT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 MULTIVOLTAGE RELAYS ONE OUTPUT RELAY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 TWO OUTPUT RELAYS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 MEASUREMENT TRANSDUCERS - TRUE RMS SINGLE PHASE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 MEASUREMENT TRANSDUCERS CURRENT - EXTERNAL POWER SUPPLY 1CORIC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 VOLTAGE - EXTERNAL POWER SUPPLY 1CORUC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 1 DIN MODULE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 RS485 CONCENTRATOR 1RCD1485 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 SURGE ARRESTERS VARISTOR SYSTEM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 WITH CURRENT LIMITER - C GROUP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 CURRENT TRANSFORMERS “HALL” EFFECT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 SHUNTS SHUNTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 3 app fotovoltaici 2010 GB:Contatori 08/10/10 12:56 Pagina 4 ANALOGUE INSTRUMENTS VOLTMETERS MOVING COIL INSTRUMENTS FOR DIRECT CURRENT MODULAR VOLTMETER ERCM - BURDEN 1000Ω/V - CLASS 1,5 - RANGES MILLIVOLTMETERS: from 60 to 600 mV direct input VOLTMETERS: 1-1,5-2,5-4-5-6-10-15-20-25-40-60-100-150-250-300-400-500-600V direct input Different capacities can be carried out on request - DIMENSIONS / WEIGHT 3 DIN modules / 0,20 kg - EXAMPLES WHEN ORDERING ERC■ M■ ■ 30V■ ■ D direct input, end scale value 30V ERC■ M■ 250V■ ■ D direct input, end scale value 250V + - L1 N VOLTMETER (90°) ERC48 - ERC72 - ERC96 - ERC144 VOLTMETER (240°) ERCL48 - ERCL72 - ERCL96 - The main characteristic of these instruments is their low current consumption, in circuits where high internal consumption and drop in voltage can bring about measuring errors. The low consumption means that these instruments can also be used with converters, tacho generators or thermocouples. Up to 60A they can be provided with an incorporated shunt for direct connection, above 60A use a separate shunt. - BURDEN 1000Ω/V - CLASS 1,5 - RANGES MILLIVOLTMETERS: 60-100-150-250-400-600mV VOLTMETERS: 1-1,5-2,5-4-6-10-15-25-40-60-100-150-250-300-400-500-600V Different capacities can be carried out on request - EXAMPLES WHEN ORDERING ERC■ 72250V■ ■ D direct input, end scale value 250V, 90° ERC■ 96■ ■ 5V■ ■ D direct input, end scale value 5V, 90° ERCL72250V■ ■ D direct input, end scale value 250V, 240° - WEIGHT (kg) ERC48 (0,10); ERC72 (0,20); ERC96 (0,25); ERC144 (0,35) ERCL48 (0,21); ERCL72 (0,30); ERCL96 (0,40) VOLTMETER WITH 2 ALARM THRESHOLDS ERCC96V - ERCC96V24 - ERCC96V110 - BURDEN 3VA - POWER SUPPLY standard 230V +/-10% - DC auxiliary supply on request - FREQUENCY 45/65 Hz - RANGES 1-10-50-100-300-600V - Different capacities on request - RELAYS DATA Max interruption power with resistive laod 2kVA (8A,250V) ERCC96V=AL 1 (MIN) AL 2 (MAX) ERCC96VMA=AL 1 (MAX1) AL 2 (MAX2) ERCC96VMI=AL 1 (MIN1) AL 2 (MIN2) ERCC96VMM=AL 1 (MAX-) AL 2 (MAX+) - SIGNALLING DATA Adjustments by 2 frontal buttons Class +/- 1,5% referred to the end scale value Hysteresis < 1% of end scale value Delay time from 1 to 15 seconds, selectable by minidip situated under the white frame - How to select the alarms: press the button (AL1 or AL2) and maintain pressure until the lower led moves to the needed value. In alarm condition all leds flash quickly - EXAMPLES WHEN ORDERING ERCC96V■ ■ 600V MIN/MAX voltmeter, end scale 600V (230VAC) - WEIGHT (kg) 0,50 Default delay time selection AL1=1 sec AL2=1 sec C AL1 Input V 230V AL 1=1sec AL 2=1sec AL 1=3sec AL 2=5sec AL 1=15sec AL 2=1sec AL 1=1sec AL 2=3sec AL 1=3sec AL 2=15sec AL 1=15sec AL 2=3sec AL 1=1sec AL 2=5sec AL 1=5sec AL 2=1sec AL 1=15sec AL 2=5sec AL 1=1sec AL 2=15sec AL 1=5sec AL 2=3sec AL 1=15sec AL 2=15sec AL 1=3sec AL 2=1sec AL 1=5sec AL 2=5sec AL 1=3sec AL 2=3sec AL 1=5sec AL 2=15sec PANEL VOLTMETER EMC55M - EMC70M VOLTMETER WITH 55R OR 70R FRAME EMC55M+A55RE - EMC70M+A70R VOLTMETER WITH 55N OR 70N FRAME EMC55M+A55NE - EMC70M+A70N - Front in plastic, transparent acrylic with antistatic as standard - BURDEN 1000Ω/V - CLASS 1,5 - RANGES MILLIVOLTMETERS: 60-100-150-250-400-600mV VOLTMETERS: 1-1,5-2,5-4-6-10-15-25-40-60-100-150-250-300-400-500-600V Different capacities can be carried out on request - EXAMPLES WHEN ORDERING EMC■ 70M300V■ ■ D direct input, end scale value 300V, diameter 70mm - WEIGHT (kg) 0,18 4 C AL2 Delay time selection app fotovoltaici 2010 GB:Contatori 08/10/10 12:56 Pagina 5 VOLTMETER (HORIZONTAL PROFILE VERSION) ERPC24/O VOLTMETER (VERTICAL PROFILE VERSION) ERPC24/V - BURDEN 1mA - CLASS 1,5 - RANGES: MILLIVOLTMETERS: 60÷300mV VOLTMETERS: 1-1,5-2,5-4-6-10-15-30-40-50-60-80-100-150-200-250-300-400-500-600V Different capacities can be carried out on request - EXAMPLES WHEN ORDERING ERPC24/V■ 100V■ D direct input, end scale value 100V (vertical) ERPC24/O■ ■ 10V■ D direct input, end scale value 10V (horizontal) + - AMMETERS MOVING COIL INSTRUMENTS FOR DIRECT CURRENT MODULAR AMMETER - BURDEN - CLASS - RANGES MICROAMMETERS: MILLIAMMETERSI: AMPEROMETRI: ERCM 60mV 1,5 100-150-250-400-500-600µA direct input from 1 to 600 mA 4/20mA direct input 1-1,5-2,5-4-5-6-10-15-20-25-30A direct input .../60mV input by shunt, secondary 60mV Different capacities can be carried out on request - DIMENSIONS / WEIGHT 3 DIN modules / 0,20 kg - EXAMPLES WHEN ORDERING ERC■ M■ ■ 60MV■ ■ S input by shunt, secondary 60mV, without scale plate ESC■ M■ 200A■ ■ 60MV scale plate for ERCM, 200A/60mV ERC■ M■ ■ ■ 5A■ ■ D direct input, end scale value 5A L1 N + - + - Direct input Shunt input AMMETER INTERCHANGEABLE SCALE PLATE (90°) ERC48 - ERC72 - ERC96 - ERC144 AMMETER INTERCHANGEABLE SCALE PLATE (240°) ERCL48 - ERCL72 - ERCL96 - The main characteristic of these instruments is their low current consumption, in circuits where high internal consumption and drop in voltage can bring about measuring errors. The low consumption means that these instruments can also be used with converters, tacho generators or thermocouples. Up to 60A they can be provided with an incorporated shunt for direct connection, above 60A use a separate shunt. - BURDEN 60mV - CLASS 1,5 - RANGES MICROAMMETERS (ERC) 50-60-80-100-150-250-400-600-800-900µA MICROAMMETERS (ERCL) 100-150-250-400-600-800-900µA MILLIAMMETERS: 1-1,5-2,5-4-5-6-10-15-20-25-40-60-100-150-250-400-600-800-900mA 4/20mA AMMETERS: 1-1,5-2,5-4-6-10-15-25-40-60A direct input .../60mV, .../150mV input by shunt, secondary 60mV or 150mV Different capacities can be carried out on request - EXAMPLES WHEN ORDERING ERC■ 96■ 60A■ D direct input, end scale value 60A, 90° ERC■ 96■ 60MV■ ■ S input by shunt, secondary 60mV, without scale plate ESC96300A600MV scale plate for ERC96, 300A/60mV - WEIGHT (kg) ERC48 (0,10); ERC72 (0,20); ERC96 (0,25); ERC144 (0,35) ERCL48 (0,21); ERCL72 (0,30); ERCL96 (0,40) Direct input Shunt input AMMETER WITH 2 ALARM THRESHOLDS ERCC96A - ERCC96A24 - ERCC96A110 - BURDEN 3VA - POWER SUPPLY standard 230V +/-10% DC auxiliary supply on request - FREQUENCY 45/65 Hz - RANGES MILLIAMMETERS: 1-20-4/20 mA (other on request) AMMETERS: 60mV, input by shunt (other on request) - RELAYS DATA Max interruption power with resistive laod 2kVA (8A,250V) ERCC96A=AL 1 (MIN) AL 2 (MAX) ERCC96AMA=AL 1 (MAX1) AL 2 (MAX2) ERCC96AMI=AL 1 (MIN1) AL 2 (MIN2) ERCC96AMM=AL 1 (MAX-) AL 2 (MAX+) - SIGNALLING DATA Adjustments by 2 frontal buttons Class +/- 1,5% referred to the end scale value Hysteresis < 1% of end scale value Delay time from 1 to 15 seconds, selectable by minidip situated under the white frame - How to select the alarms: press the button (AL1 or AL2) and maintain pressure until the lower led moves to the needed value. In alarm condition all leds flash quickly - EXAMPLES WHEN ORDERING ERCC96A■ ■ 100A1 MIN/MAX ammeter, end scale 100/60mV (230VAC) - WEIGHT (kg) 0,50 Default delay time selection AL1=1 sec AL2=1 sec C AL2 C AL1 Input A 230V AL 1=1sec AL 2=1sec AL 1=3sec AL 2=5sec AL 1=15sec AL 2=1sec AL 1=1sec AL 2=3sec AL 1=3sec AL 2=15sec AL 1=15sec AL 2=3sec AL 1=1sec AL 2=5sec AL 1=5sec AL 2=1sec AL 1=15sec AL 2=5sec AL 1=1sec AL 2=15sec AL 1=5sec AL 2=3sec AL 1=15sec AL 2=15sec AL 1=3sec AL 2=1sec AL 1=5sec AL 2=5sec AL 1=3sec AL 2=3sec AL 1=5sec AL 2=15sec Delay time selection 5 app fotovoltaici 2010 GB:Contatori 08/10/10 12:56 Pagina 6 PANEL AMMETER EMC55M - EMC70M AMMETER WITH 55R OR 70R FRAME EMC55M+A55RE - EMC70M+A70R AMMETER WITH 55N OR 70N FRAME EMC55M+A55NE - EMC70M+A70N - Housing in thermoplastic resin. Front in plastic, transparent acrylic with antistatic as standard - BURDEN 60mV - CLASS 1,5 - RANGES MICROAMMETERS: 50-60-100-150-250-400-500-600-800-900µA direct input MILLIAMMETERS: 1-1,5-2,5-4-5-6-10-15-20-25-30-40-60-100-150-250-400-600-800-900mA 4/20mA AMMETERS: 1-1,5-2,5-4-5-6-10-15-20-25-30-40-50-60A direct input .../60mV input with Shunt, secondary 60 mV Different capacities can be carried out on request - EXAMPLES WHEN ORDERING EMC■ 70M■ 60A■ ■ D direct input, end scale value 60A, 1In (60A), Ø70 mm - WEIGHT (kg) 0,18 Direct input Shunt input AMMETER (HORIZONTAL PROFILE VERSION) AMMETER (VERTICAL PROFILE VERSION) - BURDEN 1mA - CLASS 1,5 - RANGES: MICROAMMETERS: 25-50-100-150-200-250-500 µA MILLIAMMETERS: 1-5-10-50-100-150-200-250-500-600mA 4/20mA AMMETERS: 1-1,5-2-2,5-3-4-5A direct input .../60mV input with Shunt, secondary 60 mV Different capacities can be carried out on request - EXAMPLES WHEN ORDERING ERPC24/0■ 4-20MA direct input, end scale value 4/20mA ERPC24/O ERPC24/V Direct input Shunt input HOUR METERS - The hour meters are instruments for measuring time which are particulary suitable for: - determing the functioning time of electrical machines, elevators, boilers, electrical stoves etc. - determing the intervention time for changing the oil, replacing ball bearings etc. on machinery that is in constant use. - determing the functioning time of new machinery with the purpose of establishing when the guarantee expires, such as current rectifiers, valves, lamps etc. - determing the sum of the periods during fatigue tests, the duration of electrochemical processes etc. - In the DC version the movement of the motor is adjusted by a quartz crystal with great stability and a frequency such that, at every 22 degrees of oscillation, an impulse is released when amplified, activates electromagnetic converter. The display is composed by 6 entires and 1 decimal (4 mm height) - At the end of the counter, the counting begin again automatically from zero. It is not possible to reset the device. - The necessary voltage is 1,2....1,6V. - The precision is obtained by means of a variable condenser with a tolerance of +/-0,2 sec/day at room temperature. - Operating temperature: between -10°C and +55°C. Mounting position is indifferent and the housing is in black plastic material. - The reading class is 1/100 h (36 sec). This hourmeters are manufactured following the UL, IEC, TGL21-366, DIN Standards 4RK30 Fast-on 6,3x0,8 mm with screws terminal - Dimensions in mm 4RH72 4RH96 4RK46 ADAPTER FRAMES for 4RK46 for 4RK30 AMRK2448 AMRK4848 6 AMRK5555 AMRK7272 AMRKO58 AMRKO72 AM72 app fotovoltaici 2010 GB:Contatori 08/10/10 12:56 Pagina 7 FIXING SYSTEMS 4RK46 4RK46B 4RK46D DIN rail mounting 4RK46G Fast and “U-bolt” fixing system Fast fixing system RANGE SWITHCBOARD VERSION 4RK46Q 4RK301236C 4RK461050C 4RH721050C 4RH961050C 4RK47R DC CURRENT 4RH from 0,07 to 2W 10...50 V - BURDEN - POWER SUPPLY (to specify) 4RK30 from 0,04 to 0,2W 12...36V - DISPLAY - PROTECTION DEGREE - 999999,9 h (6 entires + 1 decimal) 4RK46 = IP54 IP40 4RH72 / 4RH96 = IP52 Using the AM72 frame with the hourmeter type 4RK46, this device change the external dimensions into 74x74 mm Model 4RK30 is supplied complete of fast fixing system and AMRK2448 frame Model 4RK46 is supplied with fast fixing system and “U-bolt” fixing system Model 4RK46D has DIN rail mounting system on the back. WEIGHT (kg): 4RK46 (0,09), 4RH72 (0,18), 4RH96 (0,20), 4RK30 (0,05) 4RK7R 4RH.... 4RK30 4RK46.... AC AND DC CURRENT 4RK47R - 4RK46Q 10...60V / 80...150V / 150...250V (+10% / -15%) 99999,99 h (5 ent. + 2 dec.) IP65 4RK46+AM72 4RK46B... 7 app fotovoltaici 2010 GB:Contatori 08/10/10 12:56 Pagina 8 DIGITAL INSTRUMENTS VOLTMETERS 800V DC + option RS485 + option 4/20mA DEPTH 82 mm Power supply 800V 2RCD96V230G-800 2RCD96V230G-800-RS 2RCD96V230G-800420 - 2RCD72V230-800 2RCD48V230G-800 2RCD36V230-800 2RCD72V230--800-RS 2RCD48V230G-800-RS 2RCD36V230--800-RS 2RCD72V230--800420 2RCD48V230G-800-RS 2RCD36V230--800420 BURDEN / CLASS 0,5VA / 0,5% ±2 digit referred to the end scale POWER SUPPLY 230VAC ±10% standard 50/60Hz. For different supply see the codes on the order examples. DISPLAY 1 display 4 digits red colour. 20 mm height for models 48x96 and 96x96; 14 mm height for models 36x72 and 72x72 DC RANGE 800V - PROGRAMMING see following pages As option, it is possible to have this range with an output RS485 MODBUS RTU (insulation 3kV). Option not available for model 36x72 mm with DC auxiliary supply. Option 4/20mA (passive 2 wires aux supply 20...30VDC). This analogue output cannot be present together with option RS485. Power supply 20...30VDC 4/20mADC - A RS485 B Red led = active current loop (4mA at least) Power supply 800V + PLC - ORDER EXAMPLES 2RCD36V230G-800 (2RCD36V230--800-RS) power supply 230VAC - 36x72mm (output RS485) 2RCD48V110G-800 (2RCD48V-P2G-800420) power supply 110VAC - 48x96mm (output 4/20mA) power supply 22....36VAC and 19....70VDC - 72x72mm (output RS485) 2RCD72V-P1--800 (2RCD72V-P1--800-RS) WITH THRESHOLD ALARM - DEPTH 82 mm C AL1 2RCD96V230GS800 - 8 2RCD72V230-S800 BURDEN / CLASS POWER SUPPLY DISPLAY 1 display 4 digits red colour. DC RANGE THRESHOLD ALARM RELAYS CHARACTERISTICS ORDER EXAMPLES 2RCD48V-24GS800 2RCD96V-P2GS800 2RCD48V230GS800 C AL2 2RCD36V230-S800 0,5VA / 0,5% ±2 digit referred to the end scale 230VAC ±10% standard 50/60Hz. For different supply see the codes on the order examples. 20 mm height for models 48x96 and 96x96; 14 mm height for models 36x72 and 72x72 800V 2 - PROGRAMMING see following pages 8A, 250V power supply 24VAC, input 500V or 100V - 48x96mm power supply 44....130VAC and 70....240VDC, input 500V or 100V - 96x96mm 800V Power supply app fotovoltaici 2010 GB:Contatori 08/10/10 12:56 Pagina 9 AMMETERS 5A (1A) or 60mV with “I max demand” + option RS485 + option 4/20mA Having the possibility of RS485 MODBUS RTU interface, it become easy to control the panel strings status. In order to calculate the power, with data received in MODBUS it is enough in DC to make a simple multiplication (P=VxI) DEPTH 82 mm 60mV Power supply 5A - 2RD96A230G 2RD72A230 2RD48A230G 2RD36A230 2RD96A230G-RS 2RD72A230--RS 2RD48A230G-RS 2RD36A230--RS 2RD96A230G-420 2RD72A230--420 2RD48A230G-420 2RD36A230--420 0,5VA / 0,5% ±2 digit referred to the end scale BURDEN / CLASS 230VAC ±10% standard 50/60Hz. For different supply see the codes on the order examples. POWER SUPPLY 0÷100 Hz FREQUENCY DISPLAY 1 display 4 digits red colour 20 mm height for 48x96 and 96x96, 14 mm height for 36x72 and 72x72 from 5,00 to 9999 - PROGRAMMING see following pages AC/DC RANGE • Input 5A - it is necessary to connect the CT .../5A correspondent to the end scale value setted. Input from 0500 to 9999A with 5A steps, selectable by a frontal button. lower ranges than 500A can be selected using the “Dot” function in “Programming page”. • Input 1A - This range is obtained multiplying the primary value of CT to use for the constant K= 5 (example: 1000/1A -> K=5000). Practically, if the primary current is 1000A, you have to connect the CT 1000/1A but on the programming page (FcS) you have to select 5000. The maximum CT in this case must be 2000/1A and the precision class is 1%. • Input 60mV - It is necessary to connect the shunt.../60mV correspondent to the end scale value setted These ammeters have the possibility to effect two measures (integrated on the time): - The medium current (AC+DC) in a certain time by a “fluent window” (Current Demand) selectable from 5 to 30 minutes (resolution 1 minute) - The maximum value reached by the medium current (Max Current Demand) during all the working period of the instrument (settable parameter) THE CONNECTION OF THESE 2 INPUTS CANNOT BE EFFECTED CONTEMPORARY. If 5A input is used, it is non possible to connect the 60mV terminals also and viceversa. Once the adhesive label is removed, Revalco is not responsible to damages caused by a wrong connections. As option, it is possible to have this range with an output RS485 MODBUS RTU (insulation 3kV). Option not available for model 36x72 mm with DC auxiliary supply. -M2 -MIS +M2 +MIS This label covers the terminals related to the lower voltage input in order to avoid wrong connections. A RS485 B 60mV -M2 -MIS +M2 +MIS Power supply 20...30VDC Option 4/20mA (passive 2 wires aux supply 20...30VDC). This analogue output cannot be present together with option RS485. Red led = active current loop (4mA at least) 4/20mADC - ORDER EXAMPLES 22....36VAC and 19....70VDC, input 5A or 60mV - 72x72mm (output RS485) 2RD72A-P1 (2RD72A-P1-RS) 2RD96A-P2G (2RD72A-P1-420) 44....130VAC and 70....240VDC, input 5A or 60mV - 96x96mm (output 4/20mA) Power supply 5A + - PLC WITH THRESHOLD ALARM - DEPTH 82 mm C C AL1 2RD96A230GS 2RD72A230-S 2RD488A230-S 2RD48A230GS 2RD36A230-S 0,5VA / 0,5% ±2 digit referred to the end scale BURDEN / CLASS 230VAC ±10% standard 50/60Hz. For different supply see the codes on the order examples. POWER SUPPLY 0÷100 Hz FREQUENCY 1 display 4 digits red colour DISPLAY 20 mm height digit for 48x96 and 96x96, 14 mm height digit for 36x72 and 72x72, 8 mm height digit for 48x48 - On 48x48 model the left upper side led is lighted-on with DC measures only from 5,00 to 9999 - AC/DC RANGE • Input 5A - it is necessary to connect the CT .../5A correspondent to the end scale value setted. Input from 0500 to 9999A with 5A steps, selectable by a frontal button. lower ranges than 500A can be selected using the “Dot” function in “Programming page”. - The ammeters have also the possibility to calculate the “I demand” from 5min to 30min and the “I max demand”. - - - AL2 • Input 1A - This range is obtained multiplying the primary value of CT to use for the constant K= 5 (example: 1000/1A -> K=5000). Practically, if the primary current is 1000A, you have to connect the CT 1000/1A but on the programming page (FcS) you have to select 5000. The maximum CT in this case must be 2000/1A and the precision class is 1%. • Input 60mV - It is necessary to connect the shunt.../60mV correspondent to the end scale value setted 1 threshold alarm for model 48x48, 2 threshold alarms for other model THRESHOLD ALARM 8A, 250V (0,1A - 230V for model 48x48) RELAYS CHARACTERISTICS THE CONNECTION OF THESE 2 INPUTS CANNOT BE EFFECTED CONTEMPORARY. If 5A input is used, it is non possible to connect the 60mV terminals also and viceversa. Once the adhesive label is removed, Revalco is not responsible to damages caused by a wrong connections. ORDER EXAMPLES power supply 230VAC, input 5A or 60mV - 36x72mm 2RD36A230-S power supply 24VAC, input 5A or 60mV - 48x96mm 2RD48A-24GS power supply 110VAC, input 5A or 60mV - 48x48mm 2RD488A110-S power supply 22....36VAC and 19....70VDC, input 5A or 60mV - 72x72mm 2RD72A-P1-S power supply 44....130VAC and 70....240VDC, input 5A or 60mV - 96x96mm 2RD96A-P2GS see following pages PROGRAMMING 60mV Power supply 5A -M2 -MIS +M2 +MIS This label covers the terminals related to the lower voltage input in order to avoid wrong connections. -MIS +MIS 5A Alarm +M2 -M2 60mV Power supply 2RD488A230-S 9 app fotovoltaici 2010 GB:Contatori 08/10/10 12:56 Pagina 10 PROGRAMMINGS FOR SWITCHBOARD INSTRUMENTS SERIE 2RD.... DEPTH 82 mm Measurements displaing: the measurements and signalling pages which appear (pushing and releasing the frontal button) are the following PUSHED BUTTON RELEASED BUTTON DESCRIPTION TRMS value (AC+DC). The measured value which appear is the true RMS. The measure doesn’t has any mark AC+DC value (if voltmeter) AC+DC value (if ammeter) To enter in programming page, make a long pressure (4 seconds about) on the front button. When the programming request is recognised “ Set” page appears. Releasing the button all words will flash quickly, this situation will remain until the end of procedure. After 4 seconds the pages with configuration parameters start to be displayed; one every 4 seconds showing the actual selected value. If it is necessary to see the values without any modification don’t touch nothing until the automatic end of the showed pages. To change the values of parameters, it is enough to press the frontal button while this parameter is displayed. To fast forward maintain pressure on the frontal button. The value is automatically saved in permanent way when the automatic display of the pages starts again. The following programming pages can be present or not depending by the model used. DEFAULT PARAMETER POSSIBLE VALUES End scale selector VALUE from 0 to 1 End scale average VALORE tra 5 e 30 Max Demand Interval. This page select the control period in Minutes, so the samplement numbers of medium current (I) in 1 minute on which is possible to calculate the Iavg (current demand). Every minute a new medium value of current (I) is inserted and the oldest will be eliminated. Default value 30. VALUE from 500 to 9999 This page selects the end scale value (except the dicimal point) which must be shown when the input signal is maximum. For DC measurements there is simmetricity also for negative values obtained when the input polarity is inverted. Used in combination whit “SSc” parameter it permits personalized visualizations. Default value 500.0 VALUE from 1 to 255 It is the number (n) of single measures effected on the electrical parameter before it’s visualization on the display. Practically it is the filter of the measure stabilization. The numbering rise up from 1 to 255; more higher is the selected number, more slow are the eventual variations of reading. This is valid for all the measured parameters. Default value 30. Selects the position of decimal point. The end scale value is showed, and after every pressure of button, it change the position as per the following sequence: 500.0 (default decimal); 50.00 (centesimal); 5.000 (millesimal); 5000 (entire value) decimal point beginning scale This page selects the full scale calibration. To grant the maximum accuracy, the input value applied to terminals +MIS and -MIS is calibrated in different way respect to terminals -M2 and +M2. If FcS = 0 is selected, you have to connect teminals +MIS/-MIS (500V or 10V or 5A) If FcS = 1 is selected, you have to connect teminals -M2/+M2. (100V or 1V or 60mV) Current Max Demand Reset.This is not an operative parameter. By pressing the button (when this page appears) the Imax and Iavg values go to zero and all memorized samplements are eliminated, except the actual samplement which will be memorized after 1 minute. This phase is very quick and immediately the instrument goes out from programming. Reset max Demand Max Demand Interval DESCRIPTION VALUE from -9999 to +9999 Select a beginning scale correction (except the decimal point) used to obtain a certain value when input signal is 0 or when the input signal is 0 or has an initial value. Default value 0. Pratical example of SSc and FSc parameters: from a converter you have a signal 4/20mA which rappresent a current 0-300A, we want that an ammeter with input 20 mA (calibrated to the max current 20mA) gives this indication. Solution: assuming that we need 4 mA = 0 and 20 mA = 300 = FSc we will use the formule: VALMIS = 300x4 = 60 knowing that VALMIS at 4mA (with SSc = 0) is a direct proportion of FSc. 20 To have the SSc value (unknown) we use the following formule: 0= VALMIS FSc x (FSc - SSc) + SSc putting VALMIS to 0. Now is possible to have SSc value by the formule: SSc= VALMIS x FSc = 60 x 300 = -75 VALMIS - FSc 60 - 300 Available page for AC + DC (TRMS) readings. Selected in factory on “Yes” position - DON’T MODIFY IT Available page for AC readings. Selected in factory on “No” position - DON’T MODIFY IT Available page for DC readings. Selected in factory on “No” position - DON’T MODIFY IT Available page for percentage ondulation factor (Ripple). Selected in factory on “No” position. DON’T MODIFY IT This page actives (yes) or don’t actives (no) the vision of “Current Demand” values. Imax and Iavg switch Default value Yes. Not actived pages Actived pages zeroing MODBUS address 10 VALUE from 0 to 200 In case the display (once powered and without input connection) shows a value different from zero, select this page and set the same value pushing the frontal button. Example: is display shows 002, select 2 by the frontal button. Default value 0. VALUE from 1 to 255 This is the MODBUS node assigned to the instrument. It must be univocal on RS485 net. Default value 1. app fotovoltaici 2010 GB:Contatori 08/10/10 12:56 Pagina 11 VALUE from 0 to 4 RS485 speed RS485 serial port speed. Default value 4. 0=9600 baud rate 1=19200 baud rate 2=38400 baud rate 3=57600 baud rate 4=115200 baud rate Proper relay and led will be actived when the value of the measure will be higher than the selected limit (max threshold) active max threshold Default value “Hi”. threshold 1 or 2 activation or deactivation Proper relay and led will be actived when the value of the measure will be lower than the selected limit (min threshold) active min threshold Relay and led will be never active so the other programming pages connected with the thresholds will be not available. deactive threshold Available page only if “th1” and/or “th2” are different from “OFF” Delay time is applied during the activation. Relay will works after the selected delay time. Excitation delay threshold 1 or 2 delay application Delay time is applied during the deactivation. Relay will works after the selected delay time. Not excitation delay Available page only if “th1” and/or “th2” are different from “OFF” threshold 1 or 2 delay time VALUE from 0.0 to 25.5 This page selects the delay time value, expressed in seconds. Default value 0.2 Available page only if “th1” and/or “th2” are different from “OFF” threshold 1 or 2 source AC+DC value (UAd or AAd) The threshold is applied to the RMS (AC+DC) value Available page only if “th1” and/or “th2” are different from “OFF” It is the threshold intervention value (except the decimal point) VALUE from threshold 1 or 2 value -9999 to +9999 Default value 250 11 app fotovoltaici 2010 GB:Contatori 08/10/10 12:56 Pagina 12 MULTIFUNCTION METERS LCD - 4 DIN MODULES D.C. VERSION DIMENSIONS in mm 58 - Weight kg 0,70 - Sealable terminals cover included 85 45 70 GENERAL DESCRIPTION The 4 DIN instrument is suited for use in industrial and civil market, specially on sectors related to the production of alternative energy (photovoltaic, wind energy) . Simple and extremely compact, it features an alphanumerical display with 2 lines of eight-character lines, 6 auxiliary LEDS and 2 buttons for display selection and keyboard programming. The machine is extremely user-friendly and information is presented clearly on the display. It is unlikely you will need to consult instruction manual which is not generally kept readily available at the site. When properly installed, the instrument measures the current from external shunt ..60mV. The instruments have the possibility to select the current end scale value between 5,0 A to 3000 A DC by steps of 5,0A. Two principal families (direct and “H” insertion) forecast respectively the voltmeter measure in DC direct insertion ( -800,.0 / + 800,0 VDC) or by external voltage divider …../ 100VDC. Other executions can be manufactured on request ( ex. 24VDC, 48VDC, 150VDC etc) but must be considered as “special executions” with different costs. The instruments related to “H” family have the possibility to select the voltage end scale value between 10.0V to 3000 V DC by steps of 1,0V. The high accuracy class measures offered by each instrument are the most used on the DC field. Every direct measure (Voltage, Current and Power) is bidirectional; so the inversion of polarity is shown and the measured range is the same in positive or negative case; practically if the end scale is 3000.0A, these instruments are able to measure from + 3000,0A to – 3000,0 ADC. The individually resettable Energies and Ampere Hour can be easily calculated when you need to service the system and/or periodical test line operation, determine zone consumption values, establish cost centres, etc. NOTE: The instruments use simple Energy and Ampere Hour totalizing methods for purposes of diagnostics and statistics. These instruments cannot be considered as substitute of Energy kWhmeters. The following are provided according to model: 1 threshold with output on “N.O.” control relay (500mA/1000V), fully programmable (model “S”) 1 x RS485 3kV optoinsulated programmable high speed interface with MODBUS RTU protocol (model “RS485) PARAMETERS Electrical parameters 1RAEM4C DC • • • • • • • • • • - DC Voltage 800.0 V max - DC Voltage ..../100V by divider - DC Current .../60mV - Bidirectional power (kW) - Total active energy (Import) resettable parameter - Total active energy (Export) resettable parameter - Ampère-hour Ah+ (Import) resettable parameter - Ampère-hour Ah- (Export) resettable parameter - Total working hours - Partial working hours settable parameter - Indication of failed voltage supply - Programmed threshold V-A-W - Output relay NO (500mA/1000V) - Threshold activation signal - Threshold status summary page - Interface RS485 3kV optoinsulated 9600...115200bps - MODBUS SLAVE RTU full compliance - Remote configurable settings - Keypad configurable settings - Remote resetting of energies - ampere/hour - counter - Remote relay output control (if the threshold is OFF) - Configurable password for access to programming - Restore factory settings - Programming of initial page upon start-up - Programming of current 5 to 3000ADC with step of 5A - Programming of voltage from 10 to 3000.0VDC step 1V - Programming of analog average (VDC, ADC and W) - Download the software for free from our website www.revalco.it 12 1RAEM4C SDC • • • • • • • • • • • • • • • • • • • • • • • • • • 1RAEM4C 485DC • • • • • • • • • • • • • • • • • • • • 1RAEM4C S485DC • • • • • • • • • • • • • • • • • • • • • • • • • 1RAEM4C HDC 1RAEM4C HSDC 1RAEM4C H485DC 1RAEM4C HS485DC • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • app fotovoltaici 2010 GB:Contatori 08/10/10 12:56 Pagina 13 TECHNICAL SPECIFICATIONS Auxiliary power supply - UAUX nominal value Partial counter - Counting capacity 99999:59 hhhhhh:mm - Counting period 15 minutes - Reset YES Accuracy class 2 % max. - max rated consumption 2 VA Screens Voltmeter measuring circuits (instrument for direct insertion) - Back-lighted Display LCD, 8 characters x 2 lines, temp. -20°/+70° - Max applicable voltage (Vmax) +/- 960 VDC - Auxiliary signals 6 red LEDS - Rated voltage measurement (Vnom) +/- 800 VDC Relay control output (“S” models only) - Direct measuring field +/- 960 VDC - Type of contact N.O. - Input impedance of voltage circuit approx 2MΩ - Contact specifications 1000VAC / 0.5A AC(resistive. load) / 20VA max -Accuracy class 0.2% *2Vmax ± 2 digits - Reel-contact insulation 4.25kVAC Voltmeter measuring circuits - Remote operation via MODBUS YES, only for “S485” models (models “H” instruments; insertion from Voltage divider… /100VDC) RS485 serial interface ( “RS485” models only) - Max. applicable voltage (Vmax) +/- 125 mVDC - Insulation 3kV - Rated voltage measurement (Vnom) +/- 100 mVDC - Max communication speed 115.200 bps - Direct measuring range +/- 125 mVDC. - Communication protocol MODBUS RTU Full-compliant / JBUS - Imput impedance about 250 KΩ - Programmability and remote controls YES - End scale Range FsV +/-10VDC.....+/-3000VDC step 1V Special functions -Accuracy Class 0.2%*Vmax ± 2 digit - 3-digit password for programming the settings Ammeter measuring circuits for Shunt …/60mV - Black-out indicator system - Max applicable current (Vmax) +/- 72 mVDC Mechanical properties - Rated voltage measurement (Vnom) +/- 60 mVDC - Dimensions Standard 4 DIN modules - Direct measuring range +/- 72 mVDC. - Type of mounting DIN50022 bar - Imput impedance about 50 KΩ - Degree of protection complete device IP20 - End scale Range FsA +/-15ADC.....+/-3000ADC step 5A Front IP30 -Accuracy Class 0.2%*2Vmax ± 2 digit Environmental conditions Power measurement - Operating temperature: Nominal range 0...+45 °C - Measurement capacity for direct insertion (end scale) ±3,57 MW Extreme range -5...+55 °C - Measurement capacity for “H” models (end scale) ±12,96 MW - Storage temperature -10...+70 °C -Accuracy class 0,5 % full scale ± 2 digits - Relative humidity 10...95 % Energy totalizing - Atmospheric pressure 70...110 kPa - Counting capacity 99999999kWh Standards - Counting period 15 minutes - Safety CEI EN 61010-1 300V CAT III - Reset YES - Accuracy class CEI EN 60688 (ex EN 50082-2) -Accuracy class 2 % max. - Electromagnetic compatibility (immunity) CEI EN 61000-6-2 (ex EN 50081-2) Ampere-Hour totalizing - Electromagnetic compatibility (emission) CEI EN 61000-6-4 - Counting capacity 99999999 Ah - Cover protection (IP code) CEI EN 60529 - Counting period 15 minutes Modbus: - Reset YES -Protocol specifications V1.1b, 28.12.2006 -Accuracy class 2 % max. Operating counter - Counting capacity 99999:59 hhhhhh:mm - Counting period 15 minutes - Reset NO Accuracy class 2 % max. 110 230 -P1 -P2 110V 50/60Hz 230V 50/60 Hz 22...36VAC and 19...70VDC 44...130VAC and 70....240VDC GENERAL OPERATION (FOR ALL MODELS) The instrument calculates and monitors the electrical measurements of the plant to which it is connected. It displays the information on the selected pages of display by quick pressure of the buttons. The right button is for “next” and the left button is for “previous” page. The 6 LEDS on the right help to indicate the main electrical measurement pages and switch on according to the type of measurement shown on the display at the time. The first measurement page that appears upon start-up can be programmed. The “S” models with threshold allow you to configure the measurement to be controlled, the type of threshold (off, maximum or minimum), the millesimal threshold value in relation to the full scale of the controlled measurement, time delay upon activation or deactivation, if applicable, and the time delay in tenths of a second up to 25.5 seconds (0=no delay). Refer to the “Programming” section for details on programming values and the “Operation of the programmable threshold” section. The “RS485” models with RS485 interface can communicate via network when they are assigned a programmable address between 1 and 255. You are advised not to put more than 32 devices on a network so as to ensure reliable communication. If this is not adequate, there are “special” versions able to support more than 64 devices. Communication speed can be set at between 9600bps and 115,200bps.You are advised to set the communication speed at maximum if only these devices are used. If the speed is set too low and there are frequent requests and/or there is a high number of required records, interactions with the instrument may also slow down. Allmeasurements and parameters can be viewed on the MODBUS RTU reader interface. The instrument also enables “on the fly” remote programming of the work settings via the MODBUS writer interface with the respective records that support it. In certain situations you are also allowed to carry out some macro-operations and controls, such as restoring the factory settings of models that enable this, resetting of the totalizers or direct switching on and off of the output relay for models with threshold. Note: the “RS485” models offer additional measurements via MODBUS, in particular the TRUE RMS values to verify the presence or not of ripple or alternate components residuals. All models feature a blackout indication page. It is like the measurement page but with flashing content which has to be programmed like the initial page shown on start-up. When you press the keys to change the measurement page, the “blackout” condition is reset. This is proposed again after any programming of the settings on the keyboard. All models feature 2 hour counters; one for total operation and another that can be resetted. The latter allows you to check the average consumption if resetted together with one or more Energy totalizers. All models require a 3-digit password (that can be excluded) to change the work settings and reset the counters. This password is not intended to guarantee full protection but to prevent accidental access to the programming area and ensure the settings are not changed by someone not authorized to do so. There is no easy way to recover or cancel a password that has been configured and then forgotten. You will have to try all the combinations or return the product to the factory for reprogramming. 13 app fotovoltaici 2010 GB:Contatori 08/10/10 12:56 Pagina 14 NOTES AND OPERATING INSTRUCTIONS DO NOT PRESS ANY OF THE KEYS while switching on the instrument (i.e. when connecting it to the auxiliary power supply). Otherwise you may accidentally start the calibration procedure normally carried out at the factory which, if the instrument is connected to the system rather than to the respective calibration devices, could cause the instrument to be permanently not calibrated. In the interest of safety, ALWAYS WAIT FOR THE INITIAL DIAGNOSTICSTO FINISH (scanning of the LEDS) before pressing any of the keys. “S” instruments with threshold: The threshold relay is blocked for the first ten seconds after the instrument is switched on. The relay is “frozen” until you have finished configuring the settings. 1RAEM4C DC / ...SDC / ...485DC / ...S485DC 1RAEM4C HDC / ...HSDC / ...H485DC / ...HS485DC OPERATION When you start up the device, the firmware information page appears for a few seconds and all the LEDS switch on in sequence (initial diagnostics). You will then see, for a few seconds, the page with the “title” of the measurements that will appear on the display, and the respective LED will switch on if the page requires it to do so. When the first measurement page appears, you can press the buttons to scroll through the available pages. You can scroll FORWARDS by QUICKLY PRESSING the RIGHT-HAND button, or BACKWARDS by pressing the LEFT-HAND button. Pressing and holding the right-hand button will take you to the next page as well as allow you to program the instrument’s settings. Pressing one of the 2 buttons quickly displays the “title” of the measurement page to be displayed The measurement and indication pages which can be accessed by pressing and Quickly releasing the RIGHT-HAND button are the follows: Appears only for about 3 seconds when the instrument is switched on. 03.12.08 Provides information on the instrument’s firmware and operating details. 84.00.00 When this page is displayed, the LEDS flash quickly to indicate they are working properly. Black-out page. For this to appear, it has to be configured as the default page. Appears only when the instrument is switched on. It disappears as soon as the display is moved. It reappears after the settings are configured using the keypad. PowerOn Ready INFO page. Indicates the instrument model and version. The lightt-up square (first line on the right) indicates the voltage phases are OUT OF SEQUENCE. The square does not appear when the sequence is correct. Only in the case of the “RS485” models does the last value at the bottom on the right indicate the node number of the instrument on the MODBUS network. RAECSDCH 485:001 PRESSED BUTTON WHEN RELEASED Volt DC Volt DC 100.0 DESCRIPTION Value of DC Voltage component, with + or - (V) DC Voltage measure Amp DC Amp DC -100.0 Value of DC Current component, with + or - (A) DC Current measure kW DC kW DC -10.00 Value of DC Power component, with + or - (kW) DC Power measure kWh+ kWh+ 78973588 Total positive Energy (kWh) Positive Energy totalizing kWh- kWh1347 Total negative Energy (kWh) Negative Energy totalizing Ah+ Ah+ 1546170 Total positive Ampere-hour (Ah) Positive Ampere-hour totalizing Ah- Total negative Ampere-hour (Ah) Ah2723 Negative Ampere-hour totalizing T Time T Time 97163:58 Total counter 14 Operating time in hours and minutes (hhhhh:mm) app fotovoltaici 2010 GB:Contatori 08/10/10 12:56 Pagina 15 R Time Time since last reset, in hours and minutes (hhhhh:mm) R Time 80445:21 Partial counter Out FOR “S” MODELS ONLY Status of output relay contact (On=closed) and source of the threshold Out= On Src= Wt Relay OPERATION OF THE PROGRAMMABLE THRESHOLD (“S” models only). These models allow you to apply a max or min threshold as a percentage of the required size, in relation toits intended full scale. Required parameter (Th1 Src) Full scale (= 100.0%) Description kW+ FsA * FsV Max/Min instantly consumed positive Active Power kWFsA * FsV Max/Min instantly consumed negative Active Power A+ FsA Max/Min positive current AFsA Max/Min negative current V+ FsV Max/Min positive voltage VFsV Max/Min negative voltage The threshold activation (threshold active) point is the condition “more than Th1 Val” if Th1 Sel = Hi; otherwise “less than Th1 Val” if Th1 Sel = Lo The threshold’s quiescent operating (threshold inactive) point is the condition “less than or equal to Th1 Val” if Th1 Sel=Hi; otherwise “more than or equal to Th1 Val” if Th1 Sel=Lo. OFF ON - Hi + 0 OFF - OFF - ON 0 Hi ON Lo + 0 OFF ON + - 0 Lo + The “active threshold” condition attempts to CLOSE the relay’s “N.O.” contacts and this occurs instantly unless there is the delay Th1 Dly if Th1 DD is “Off-On” The “inactive threshold” condition attempts to OPEN the relay’s “N.O.” contacts and this occurs instantly unless there is the delay Th1 Dly if Th1 DD is “On-Off”. There are 2 cases whereby the output relay does NOT mirror the threshold condition. These are as follows: - During the first 10 seconds from starting up the instrument, when the relay is kept inactive to avoid unwanted operation while the measurements are stabilized, and - when the settings are being programmed on the keypad, it is kept at the same status at the time of starting the procedure, to prevent partial modification of the settings from causing unwanted change to its status. Relay status is shown on the display at page “OUT”, together with the title of the size of the threshold selected in Th1 Src. Closing of the relay also determines flashing of the LED associated with the selected size (when applicable), providing the selected measurement page is not the one associated with the LED, in which case the LED light remains steady. “RS485” Models: when Th1 Sel=OFF (threshold OFF), there is the option of controlling the relay directly by means of MODBUS commands to open and close INSTANTLY, regardless of the Th1 Dly and Th1 DD settings. “Src=REM”(REMOTE) appears on the OUT page to indicate remote access of the relay. PROGRAMMING For programming, press and hold the RIGHT-HAND button (for 4 seconds or more). The first page to appear when you are granted access to the programming mode is the one of programmable values. Releasing the button will make the display flash (to indicate you are in programming mode) and the pages begin to scroll through slowly (one every 4 seconds or so), indicating the title and value of the current set-point. If you do not touch the button when you get the last page, normal operation is restored without saving any changes. To make a change, simply press one of the buttons when the required page appears, respectively: LEFT-HAND button = DECREASES the value; RIGHT-HAND button = INCREASES the value. At that point (after pressing the button) the display remains steady so you can check the modification and the value changes by one unit. If you have to modify a value quite considerably, you can press and hold the button for more than 2 seconds to speed up the process. The longer you hold down the button, the faster you can scroll through the numbers (4 speeds). They are all “roll” values so when you get to the maximum permitted value you restarted from the minimum value, and vice versa. When you have set the value as required, release the button and wait for over 4 seconds. The pages then continue scrolling and the modification is automatically saved. Modifiable pages then follow. Program Mode Indicates you have entered the setting configuration phase. Password 000 A password is only requested if NewPassw is set at a value other than 0 (see below). Select the correct number and wait for the next page. In the case of a missing or incorrect entry, the instrument returns to normal operation after about 4 seconds. Default Param By pressing a key when this page is shown, all value parameters return equal to the factory programming, except totalizer resetting one by one. FsA Set 100 To set the Current end scale value (…./60mVDC)in Ampere. Settable between 5 and 3000 at steps of 5 Default = 100 15 app fotovoltaici 2010 GB:Contatori 08/10/10 12:56 Pagina 16 FsV Set 100 Average 25 THE WINDOWS BELOW APPLY ONLY TO THE “H” MODELS To select the Voltage end scale value from voltage divider. Selectable from 10.0V to 3000 V DC by steps of 1,0V. Default=100 Average of the analogue values measured (V, A and P). To stabilize the displayed values. More higher is the number, more stable are the measurements , although they will be slow to update. Settable between 1 and 15 at steps of 1. Default = 25 Default Page Configuration of the first measurement page to be viewed upon start-up. Using the buttons to scroll through displays the “titles” of the available pages – the same ones that appear when you press the right-hand button in sequence. Settable on all the available pages. Default = Blackout detection page NewPassw 0 Setting this at zero disables password protection for programming with the keypad. The same applies for password protection for programming by remote control. Settable between 0 and 999 at steps of 1. Default = 0 (disabled) kWh+ ->0 78973588 Resetting the Totalizer of positive Energy kWh- ->0 1347 Pressing and holding the right-hand button for more than 4 seconds, the value will be resetted kWh+ ->0 0 Resetting the Totalizer of negative Energy Pressing and holding the right-hand button for more than 4 seconds, the value will be resetted kWh-Pressing ->0 0 Ah+ ->0 1546170 Resetting the Totalizer of positive Ampere-hour Ah+ ->0 0 Pressing and holding the right-hand button for more than 4 seconds, the value will be resetted Ah- ->0 2723 Resetting the Totalizer of negative Ampere-hour Ah- ->0 0 Pressing and holding the right-hand button for more. than 4 seconds, the value will be resetted R Time->0 80445:21 R Time->0 0:00 Resetting the Partial counter Pressing and holding the right-hand button for more than 4 seconds, the value will be resetted THE WINDOWS BELOW APPLY ONLY TO THE “S” MODELS Th1 Sel Hi Th1 Dly 0.1 Th1 DD Off-On Th1 Src W+ Th1 Val% kW+ 50.0 Selecting the threshold operation mode. Settable between: Hi=High threshold, Lo=Low threshold and Off=threshold disabled. If the threshold is OFF, you will not view the following pages. Default = Hi (high threshold). Delay time for activation of the output relay (page displayed only if Th1 Sel is not Off) Expressed in seconds. Settable between 0.0 and 25.5 in steps of 0.1. Default = 0.1 Assigning the delay time for activating the threshold (page displayed only if Th1 Sel is not Off) The delay time is applicable from the start of threshold activation (Off-On) or at the end (On-Off). Default = Off-On (at the start) Assigning the size for activating the threshold (page displayed only if Th1 Sel is not Off) Settable at: kW +, k W -, V+, V-, A +, A -. Default =k W+ Regulating the threshold value as a percentage of the full scale (page displayed only if Th1 Sel is not Off) 5.00 kW+ 50.0 THE WINDOWS BELOW APPLY ONLY TO THE “485” MODELS Assigning the MODBUS address node number Node (of the “INFO”, ADR: nnn page). 1 Settable between 1 and 255. Default = 1 Speed 4 At the top is the effective value of the threshold for the selected parameter. Settable between: 0.0 and 100.0, in steps of 0.1. Default = 50.0 (%) Configuring the speed of the RS485 serial port (bps) Settable between 0 and 4 (0=9600, 1=19200, 2=38400, 3=57600, 4=115200). Default = 4 CONNECTION DIAGRAM + - + shunt .../60mV + Option for “485” version Option for “S” version 16 0,5A-1000V 20VA C N.O. + app fotovoltaici 2010 GB:Contatori 08/10/10 12:56 Pagina 17 kWh-METERS FOR DIRECT CURRENT BURDEN POWER SUPPLY ACCURACY CLASS TEMPERATURE READING RESOLUTION DISPLAY SIGNALLING LED < 4W 48V DC (40 ÷ 54 V DC) selfsupplied 2 functioning -5°C ÷ +50°C / storage -25°C ÷ +70°C 0,01 kWh 99999,99 kWh (5 entires + 2 decimals) yellow OFF = correct connection yellow ON = wrong connection it is necessary to check the measuring circuit connections, if the connection is inverted, the numberer will block and stop counting until the anomaly is resolved red flashing = active consumption NOMINAL CURRENT DC from external shunt (....A/60mV) The value of primary current must be indicated during the order between: 30A - 40A - 50A - 60A - 80A - 100A - 120A - 150A MAXIMUM ADMITTED CURRENT 1,2 In OUTPUT IMPULSES Open-Collector System (SO, DIN43864), max 36V/20mA DC - Impulse duration 100 ms DIMENSIONS / WEIGHT kg. 2 DIN modules / 0,13 open-collector - max 36V / 20mA DC 100 ms + t 6 7 3 1 4 Connection sequence: 1- Connect the shunt.....A/60mV 2- Make the other connections + 60mV shunt 48V DC - LOAD 1RCEM2C + - MULTIVOLTAGE RELAYS ONE OUTPUT RELAY 1RMR1 Wide voltage coil range for every application in VDC or VAC, range from 12....400VDC and 12....270VAC for electrical maintenance or new installation not depending by the voltage supply and electrical photovoiltaic applications. Low consumption 0.4W for pick up time; 0.2W all working time - SAFETY APPROVALS – STANDARD COIL CONSUMPTION NOMINAL FREQUENCY VOLTAGE TEMPERATURE - RELAY - CONTACT RATING (Inom) - DIELECTRIC STRENGTH N.O. C EN61010-1 / EN61810-1..ec..-2 <0.2W TRMS for all voltage supply DC or from 49Hz to 600Hz operative range -20....+55°C storage -25....+70°C led light = relay on 8 A, AC resistive load 250VAC 6 A, DC resistive load 125VDC 5000 Vrms Power Supply N.C. TWO OUTPUT RELAYS 1RMR2 Wide voltage coil range for every application in VDC or VAC, range from 12....400VDC and 12....270VAC for electrical maintenance or new installation not depending by the voltage supply and electrical photovoiltaic applications. Low consumption 0.4W for pick up time; 0.2W all working time - SAFETY APPROVALS – STANDARD COIL CONSUMPTION NOMINAL FREQUENCY VOLTAGE TEMPERATURE - RELAY - CONTACT RATING (Inom) - DIELECTRIC STRENGTH EN61010-1 / EN61810-1..ec..-2 <0.2W TRMS for all voltage supply DC or from 49Hz to 600Hz operative range -20....+55°C storage -25....+70°C led light = relay on 8 A, AC resistive load 250VAC 6 A, DC resistive load 125VDC 5000 Vrms Relay 2 Relay 1 Power Supply 17 app fotovoltaici 2010 GB:Contatori 08/10/10 12:56 Pagina 18 MEASUREMENT TRANSDUCERS - TRUE RMS SINGLE PHASE Current transducers Voltage transducers DC line power transducers Sole power supply 24VAC Sole power supply 110VAC Sole power supply 22...36VAC and 19...70VDC Sole power supply 44...130VAC and 70...240VDC 230 230 230 24 110 -P1 -P2 O R 1 C 2 A 2 3 230 -24 110 -P1 -P2 = 230VAC = 24VAC = 110VAC = 22...36VAC and 19...70VDC = 44...130VAC and 70...240VDC CODES TABLE 0 - 1 A 1COR2A... • 1COR2C... • • • • • • • • • • • • • • C -500V = input 500V AC or DC -100V = input 100V AC or DC -110V = input 110V AC or DC -150V = input 150V AC or DC -250V = input 250V AC or DC 100R3V = input 100V: 3 AC or DC 110R3V = input 110V: 3 AC or DC A = current V = voltage C = DC line power -5A50V = calibration 5A 50V DC (voltage/current measure has a common point) POSITIVE / NEGATIVE SELECTABLE OUTPUTS POSITIVE SELECTABLE OUTPUTS 1 2 3 4 5 6 7 8 9 10 1COR2V... -5DC = input 5A DC -10DC = input 10A DC -60MV = input 60mV DC (or -100MV / -150MV / -300MV) input measuring unit power supply Selectable output nominal values 1-5-10VDC and 1-5-10-20-4/20mADC ±1, ±5, ±10 VDC and ±1, ±5, ±10, ±20, 4/20 mA DC Class 0,5 Transparent sealable front cover 2 DIN modules transducers identification Auxiliary power supply: see table Input nominal values: see table Response time ≤ 300 ms Dimensions: 2 DIN modules Resistive load: 700Ω 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 4(-) 12(0) mA 20(+) AC /DC Signal input (V) Power supply + - - Power supply + + - + - - + DC Signal input (mV) V DC V DC V DC 1COR2A... 18 DC Signal input (50V) Power supply Signal input (mV) mA DC mA DC mA DC mA DC mA DC V) mA DC mA DC mA DC mA DC mA DC V DC V DC V DC 1COR2V... mA DC mA DC mA DC mA DC mA DC 1COR2C.... V DC V DC V DC app fotovoltaici 2010 GB:Contatori 08/10/10 12:56 Pagina 19 MEASUREMENT TRANSDUCERS CURRENT EXTERNAL POWER SUPPLY 1CORIC - - AUXILIARY SUPPLY (separate) 230V AC standard NOMINAL INPUT VALUES 1A and 5A present on the same transducer NOMINAL OUTPUT VALUES (selectable) 1 - 5 - 10 VDC and 1 - 5 - 10 - 20 - 4/20 mA DC RESISTIVE LOAD 700Ω MEASURING RANGE 0 ÷ In ACCURACY CLASS 0,5 OVERLOAD Permanent: 2 In Instantaneous: 10 In for 1 sec. RESPONSE TIME ≤ 300 ms ALTERNATED RESIDUAL ≤ 1% OPERATING FREQUENCY 50/60 Hz BURDEN current circuit: ≤ 0,8 VA - power supply: ≤ 4VA GALVANIC SEPARATION BETWEEN INPUTS AND OUTPUTS • insulation between inputs, outputs, power supply 2kV for 1min at 50Hz • insulation between the all circuits and earth 4kV for 1min at 50Hz OPERATING TEMPERATURE 0 °C ÷ +55 °C INPUT WAVE FORM OS DIMENSIONS / WEIGHT Kg. 6 DIN modules (3 DIN modules) / 0,54 (0,27) Different technical characteristic can be considered, under specific requests The selection of the required output is achieved by adjusting the minidip keys as described in the following diagram: Where a Voltage output is required connection is by terminal N 13 and 14; for Current output connect to terminals N 17 and 18. 10 V DC 5 V DC 1 V DC + - 13 14 4÷20 20 10 5 1 mA DC mA DC mA DC mA DC mA DC - + 17 18 7 8 10 - 12 + Input signal 60 mV Power supply + VOLTAGE EXTERNAL POWER SUPPLY 1CORUC - - AUXILIARY SUPPLY (separate) 230V AC standard NOMINAL INPUT VALUES to be specified when ordering NOMINAL OUTPUT VALUES (selectable) 1 - 5 - 10 VDC and 1 - 5 - 10 - 20 - 4/20 mA DC RESISTIVE LOAD 700Ω MEASURING RANGE 0 ÷ In ACCURACY CLASS 0,5 OVERLOAD Permanent: 2 In Instantaneous: 10 In for 1 sec. RESPONSE TIME ≤ 300 ms ALTERNATED RESIDUAL ≤ 1% OPERATING FREQUENCY 50/60 Hz BURDEN current circuit: ≤ 0,8 VA - power supply: ≤ 4VA GALVANIC SEPARATION BETWEEN INPUTS AND OUTPUTS • insulation between inputs, outputs, power supply 2kV for 1min at 50Hz • insulation between the all circuits and earth 4kV for 1min at 50Hz OPERATING TEMPERATURE 0 °C ÷ +55 °C INPUT WAVE FORM OS DIMENSIONS / WEIGHT Kg. 6 DIN modules (3 DIN modules) / 0,54 (0,27) Different technical characteristic can be considered, under specific requests The selection of the required output is achieved by adjusting the minidip keys as described in the following diagram: Where a Voltage output is required connection is by terminal Nos, 13 and 14 and for Current output connect to terminal Nos, 17 and 18. 10 V DC 5 V DC 1 V DC - + 13 14 4÷20 20 10 5 1 mA DC mA DC mA DC mA DC mA DC - + 17 18 7 Power supply + 8 10 - When ordering it is necessary to specify the required input signal 12 + Input signal (V) 19 app fotovoltaici 2010 GB:Contatori 08/10/10 12:56 Pagina 20 MEASUREMENT TRANSDUCERS - 1 DIN MODULE CURRENT TRANSDUCERS 1CORIC1 1CORIC1-20 1CORIC1-RS 1CORIC1-20-RS 24VDC +/- 10% 32mA no load, 36 mA at 4mA, 80mA 41 mA at 12mA, 47mA at 20mA 15A DC 20ADC 15A DC 20ADC 1CORUC1-20 1CORUC1-RS 1CORUC1-20-RS 24VDC +/- 10% 32mA no load, 36 mA at 4mA, 41 mA at 12mA, 47mA at 20mA 600VDC max (single or bipolar to specify when ordering) single pole 0,1 Ω 0,4 W 3 mΩ 675 mW 0,1 Ω 0,4 W - INTERNAL SHUNT (resistance) DISSIPATION POWER MAXIMUM CURRENT FOR 1 sec OUTPUT VALUES (different under request) - RESISTIVE LOAD ACCURACY CLASS RESPONSE TIME GALVANIC SEPARATION (insulation between inputs, outputs and power supply) 2kV for 1min at 50Hz TEMPERATURE -5 °C ÷ +55 °C DIMENSIONS / WEIGHT kg. 1 DIN module / 0,27 READING FILTER YES STANDARDS CE, EN 61010-1, EN 60742, EN 61000-6-4, EN 61000-6-2 FUNCTIONING INDICATORS Actual measure / Active output Actual measure 3 mΩ 675 mW 60A 4/20mA RS485 address and speedy selectable by frontal minidip 500Ω max 1% 1 sec 1CORIC1 1CORIC1-RS Power supply + Input + - Input + - Output RS485 MODBUS RTU Output 4/20mA RS485 address and speedy selectable by frontal minidip 500Ω max 1% 1 sec 2kV for 1min at 50Hz -5 °C ÷ +55 °C 1 DIN module / 0,27 YES CE, EN 61010-1, EN 60742, EN 61000-6-4, EN 61000-6-2 Actual measure / Active output Actual measure Input Input 4/20mA Power supply - 80mA + - Output 4/20mA Output RS485 MODBUS RTU RS485 CONCENTRATOR - 1RCD1485 Impulses concentrator for 2 .... 32 devices in one sole serial output RS485 - AUXILIARY SUPPLY BURDEN INPUT OUTPUT GALVANIC SEPARATION (insulation between RS485) TEMPERATURE DIMENSIONS / WEIGHT kg. DATA CONTROL STANDARDS FUNCTIONING INDICATORS 24VDC +/- 10% 80mA serial RS485 MODBUS RTU SLAVE with address and transmission speedy selectable by a frontal minidip serial RS485 (9600 Bps) MODBUS RTU master to the transducers (max 32) 2kV for 1min at 50Hz (high frequency transformer) -5 °C ÷ +55 °C 1 DIN module / 0,27 Software CRC CE, EN 61010-1, EN 60742, EN 61000-6-4, EN 61000-6-2 Red = TX master, Yellow = RX master, Green = TX slave, White = RX slave Slave RS485 - Master RS485 20 Master RS485 + - Master RS485 + - Master RS485 + - Alimentazione - Misura 32 Alimentazione + Misura 3 Alimentazione Misura 2 Alimentazione + Power supply Misura 1 Power supply - INPUT VALUES 1CORUC1 Power supply - AUXILIARY SUPPLY - BURDEN VOLTAGE TRANSDUCERS Master RS485 app fotovoltaici 2010 GB:Contatori 08/10/10 12:56 Pagina 21 SURGE ARRESTERS VARISTOR SURGE ARRESTERS 1RAOCPV / 1RAOCPV-T (with remote control) Surge arresters with internal thermis protection. Suitable for photovoltaic systems protection against direct and indirect surge arresters for installation between the photovoltaic panels and AC/DC inverter. Protective element is a varistor, so residual currents will be not present. Suitable for zone 1-2 protection according to the IEC62305 standards. Policarbonate, V0 self-extinguishing case. Optical signalling of fault. Connection can be effected with "T" system and "V" system. 1RAOCPV 40/100 1RAOCPV 40/550 1RAOCPV 40/1000 MAXIMUM CONTINUOUS VOLTAGE Ucpv (+ PE, - PE) 100V 550V 1000V MAXIMUM CONTINUOUS VOLTAGE Ucpv (+ - ) 200V 1100V 1000V PROTECTION VOLTAGE Up at In <0,7 kV <2,1 kV <4 kV MAX CURRENT DISCHARGE Imax (8/20 µs) 40 kA / polo RESPONSE TIME tA < 25 ns SHORT CIRCUIT 25 kA / 50 Hz WORKING TEMPERATURE -40°C ÷ +80°C SECTION OF WIRES 35 mm2 (single wire) - 25 mm2 (multiple wire) REMOTE CONTROL AC: 250V / 0,5A ; 125V / 3A Section of wire 1,5 mm2 max PROTECTION DEGREE IP20 CLASS (IEC / EN / VDE) II / Type 2 / C DIMENSIONS / WEIGHT kg 2 DIN modules / 0,28 2 DIN modules / 0,31 3 DIN modules / 0,40 It is possible to substitute the fault varistor (1RAOCPV-F) without the disconnection of the auxiliary power supply Internal circuit - + - Remote control + PE PE 1RAOCPV... 1RAOCPV 40/100 (550) 1RAOCPV...-T 1RAOCPV 40/100-T (550-T) Internal circuit PE + - PE - Remote control + 1RAOCPV40/1000 1RAOCPV40/1000-T 1RAOCPV 40/1000 Internal circuit + F1 F2 F1 F2 - “T” connection diagram PE F1, F2 = PV fuses 1RAOCPV 40/1000-T 21 app fotovoltaici 2010 GB:Contatori 08/10/10 12:56 Pagina 22 SCARICATORI CON LIMITATORE DI CORRENTE - GRUPPO C Dopo anni di vendite, esperienze e prove è risultato evidente al mercato, che il problema più importante da risolvere negli scaricatori fosse quello di annullare o quantomeno ridurre al massimo il rischio di incendi dovuti al formarsi dell’arco fotovoltaico nel contatto del relè termico durante la commutazione. In aggiunta al fatto che recentemente le nuove normative stanno prendendo in considerazione questa problematica, Revalco ha deciso di sviluppare una nuova generazione di scaricatori adottando una diversa tecnologia; il relè termico è collegato in linea con il varistore (MOV) e se la corrente aumenta, il secondo stadio di protezione reagisce scollegando il varistore stesso dall’alimentazione. 1. Condizione Normale 2. Come funziona 3. In caso di sovratensioni di lunga durata - In caso di sovra tensioni fino al 50% della Uc, poiché interviene il limitatore di corrente ( attorno a 10mA), il variatore (MOV) non viene danneggiato. - In caso di sovra tensioni oltre il 50% della Uc, il limitatore di corrente interviene a proteggere il relè termico T.C. T.C. - Questo nuovo sistema di protezione (brevettato) non permette la formazione dell’arco fotovoltaico; l’energia che quindi attraversa lo scaricatore è molto bassa (I2 x T) T.C. Via percorsa da sovratensioni di breve durata (transiente) Via percorsa da sovratensioni di lunga durata Il limitatore di corrente riduce la corrente che attraversa il varistore (MOV) MOV Varistore Metal-Ossido GDT Ampolla a Gas Limitatore di corrente Relè termico 1RAOSAFE C...PV / 1RAOSAFE C-T...PV (with remote control) DC circuit breaker PV PHOTOVOLTAIC MODULE - On which the protective element consists of a varistor, a gas tube with thermic protection. - Suitable for installation in sub distribution panels or close to the main device offering protection against indirect lighting overvoltages. - Category IEC/EN/VDE Class II - Type 2/C. Case in thermoplastic material, UL 94-V0 self-extinguishing. - Optical signal of fault. - Protection modes (+) + (-) - PE, (+) - PE / (-) - PE. MOV protective element. - High surge discharge rating Imax=40kA. - Standards IEC-61643-1; UTE 61740-51; EN 50539-11. - Backup fuses are not necessary Inverter + + - - L N PE 1RAOSAFE C75PV 1RAOSAFE C300PV 1RAOSAFE C600PV 1RAOSAFE C1000PV 1RAOSAFE C1200PV MAXIMUM CONTINUOUS VOLTAGE Ucpv (+ PE, - PE) 75V 300V 600V 1000V 1200V Ucpv (+ - ) 150V 600V 1200V 2000V 1200V PROTECTION VOLTAGE Up <0,6 kV <1,7 kV <2,2 kV <2,8 kV <4,6 kV NOMINAL DISCHARGE CURRENT (8/20µs) In (+) - PE / (-) - PE 20kA 12,5kA 20kA In (+) + (-) - PE 40kA 25kA 20kA MAX DISCHARGE CURRENT (8/20 µs) Imax (+) - PE / (-) - PE 40 kA 25kA 40kA Imax (+) + (-) - PE 80 kA 50kA 40kA MAX SHORT CIRCUIT WITHSTAND CURRENT Iscwpv NO LIMIT FOLLOW CURRENT If / RESPONSE TIME tA NO / < 25 ns THERMAL PROTECTION / PROTECTION DEGREE YES / IP20 TERMINAL SCREW TORQUE / TERMINAL CROSS SECTION 3,5Nm max / 35 mm2 (solid) - 25 mm2 (stranded) WORKING TEMPERATURE -40°C ÷ +80°C DIMENSIONS / WEIGHT kg 2 DIN modules / 0,40 3 DIN modules / 0,60 REMOTE CONTROL 250 VAC / 0,5A Load 125 V / 3A Section of wire 1,5 mm2 max Terminal torque 0,25Nm It is possible to substitute the fault module (1RAOSAFE CPV-F) without the disconnection of the auxiliary power supply Internal circuit - T.C. T.C. Remote control + 1RAOSAFE C 75...1000PV 1RAOSAFE C-T 75...1000PV 1RAOSAFE C...PV PE + - T.C. T.C. 14 11 12 1RAOSAFE C-T...PV PE Internal circuit + PE - + PE - T.C. T.C. T.C. T.C. T.C. T.C. 14 11 Remote control 12 1RAOSAFE C 1200PV 22 1RAOSAFE C-T 1200PV 1RAOSAFE C1200PV 1RAOSAFE C-T1200PV app fotovoltaici 2010 GB:Contatori 08/10/10 12:56 Pagina 23 CURRENT TRANSFORMERS “HALL” EFFECT Burden: < 2,5VA Auxiliary power supply 230VCA (12 - 24 - 48VDC on request) Response time 500 msec Resistive load 500 ohm max Testing voltage: 0,72kV/3kV Sealable terminals cover included Different characteristics on request Positive and negative output (except secondary 4/20mA) GENERAL DESCRIPTION Function of sensor is based on “Hall effect” fisic principe: when a magnetic field is applied in a perpendicular way to a cable, a transverse voltage to the current flux direction is generated (Hall voltage). Operative system “Open Loop (O/L)” The magnetic flux creaded by primary current IP, is concentradet in a magnetic circuit and measured on the open part of toroid by and Hall sensor. The signal exiting from this sensor is conditioned in the way to represent exactly the primary current value. This type of C.T. can be used as alternative to the shunts when high voltages are in the field and it is necesasry to have more higher galvanic separations. CONNECTION DIAGRAM FOR TAHPD1 CONNECTION DIAGRAM FOR OTHER TAH... + _ + _ Aux 230 VAC Input A Output 4/20mA Aux 230 VAC Output 4/20mA TAHPD1 76 21 Transformer with wound primary cable, primary and secondary currents on the terminals Fixing system: to wall by accessories supplied together with the current transformer Momodirectional output 18,5 44 60 3,7 121 100 55 Base Mounting dimensions 85 0,5 A secondary current 20mA secondary current 10V code code code TAHPD1-1/4-20MA TAHPD1-1/20MA TAHPD1-5/4-20MA TAHPD1-5/20MA TAHPD1-10/4-20MA TAHPD1-10/20MA TAHPD1-15/4-20MA TAHPD1-15/20MA TAHPD1-1/10V TAHPD1-5/10V TAHPD1-10/10V TAHPD1-15/10V kg weigth 1 5 10 15 class 1 secondary current 4/20mA primary current weigth kg primary current A 20 25 40 0,5 class 1 secondary current 4/20mA secondary current 20mA secondary current 10V code code code TAHPD1-20/4-20MA TAHPD1-20/20MA TAHPD1-25/4-20MA TAHPD1-25/20MA TAHPD1-40/4-20MA TAHPD1-40/20MA TAHPD1-20/10V TAHPD1-25/10V TAHPD1-40/10V 23 app fotovoltaici 2010 GB:Contatori 08/10/10 12:56 Pagina 24 TAHPD2 21 76 Fixing system: to wall by accessories supplied together with the current transformer Transformer with wound primary cable, primary current from incorporated central bar 15x3x110 mm up to 200A 25x3x135 mm up to 300A 25x5x135 mm up to 400A secondary currents on terminals 18,5 10,5 3,7 44 121 55 3(5) 100 Base Mounting dimensions ) 15 (25 60 110 (135) 85 A secondary current 10V code code code TAHPD2-50/20MA TAHPD2-60/20MA TAHPD2-80/20MA TAHPD2-100/20MA TAHPD2-150/20MA TAHPD2-50/10V TAHPD2-60/10V TAHPD2-80/10V TAHPD2-100/10V TAHPD2-150/10V weigth secondary current 20mA 50 60 80 100 150 TAHPD2-50/4-20MA TAHPD2-60/4-20MA 0,5 TAHPD2-80/4-20MA TAHPD2-100/4-20MA TAHPD2-150/4-20MA kg weigth class 1 secondary current 4/20mA primary current kg primary current A 200 250 300 400 0,5 class 1 secondary current 4/20mA secondary current 20mA secondary current 10V code code code TAHPD2-200/4-20MA TAHPD2-250/4-20MA TAHPD2-300/4-20MA TAHPD2-400/4-20MA TAHPD2-200/20MA TAHPD2-250/20MA TAHPD2-300/20MA TAHPD2-400/20MA TAHPD2-200/10V TAHPD2-250/10V TAHPD2-300/10V TAHPD2-400/10V 56 3,7 TAH4D3 21 60 18,5 Transformer suitable for primary current by cable with maximum diameter 25mm or horyzontal bar 30x10 mm; vertical bar 30x10 mm Fixing system: - to wall or DIN rail by accessories - directly to cable or busbar by screws accessories and screws are supplied together with the current transformers 44 45,5 Base Mounting dimensions 109 DIN rail accessory 10,6 30,5 30,5 10,6 87 25 Screws M3,5x38 Central section 75 A weigth secondary current 20mA 50 60 80 100 150 TAH4D3-50/4-20MA TAH4D3-60/4-20MA 0,7 TAH4D3-80/4-20MA TAH4D3-100/4-20MA TAH4D3-150/4-20MA secondary current 10V code code TAH4D3-50/20MA TAH4D3-60/20MA TAH4D3-80/20MA TAH4D3-100/20MA TAH4D3-150/20MA TAH4D3-50/10V TAH4D3-60/10V TAH4D3-80/10V TAH4D3-100/10V TAH4D3-150/10V code kg class 1 secondary current 4/20mA weigth class 1 secondary current 4/20mA primary current kg primary current A 200 250 300 400 TAH4D3-200/4-20MA TAH4D3-250/4-20MA 0,7 TAH4D3-300/4-20MA TAH4D3-400/4-20MA secondary current 20mA secondary current 10V code code TAH4D3-200/20MA TAH4D3-250/20MA TAH4D3-300/20MA TAH4D3-400/20MA TAH4D3-200/10V TAH4D3-250/10V TAH4D3-300/10V TAH4D3-400/10V code TAH5 21 76 Transformer suitable for primary current by cable with maximum diameter 30mm or bus bar: horyzontal 30x30 - 40x25 - 50x20 mm; vertical 30x10 mm Fixing system: - to wall by accessories - directly to cable or bus bar by screws accessories and screws are supplied together with the current transformer 18,5 45 52,1 42,2 60,7 100 25,3 34,2 31,3 21,4 3,7 121 12 Base Mounting dimensions 34,3 54 Central section Screws M3,5x38 85 24 0,5 secondary current 20mA A secondary current 10V code code code TAH5-100/4-20MA TAH5-150/4-20MA TAH5-200/4-20MA TAH5-100/20MA TAH5-150/20MA TAH5-200/20MA TAH5-100/10V TAH5-150/10V TAH5-200/10V 250 300 400 kg weigth class 1 secondary current 4/20mA primary current 100 150 200 kg weigth primary current A 0,5 class 1 secondary current 4/20mA secondary current 20mA secondary current 10V code code code TAH5-250/4-20MA TAH5-300/4-20MA TAH5-400/4-20MA TAH5-250/20MA TAH5-300/20MA TAH5-400/20MA TAH5-250/10V TAH5-300/10V TAH5-400/10V app fotovoltaici 2010 GB:Contatori 08/10/10 12:56 Pagina 25 SHUNTS The purpose of the shunt is to permit the passage of the current which exceeds the capacity of the instrument. The latter will therefore be supplied only with a current which corresponds to its capacity, thus avoiding the risk of damaging the measuring equipment. The shunts are resistances of very little value and for this reason they are at times formed by conductors with a bar of limited length and substantial rectangular section. For heat dissipation several bars in parallel are used, terminating in two clamps with a large contact surface. Alongside the two current clamps there are a further two clamps which serve to connect the ammeter.These clamps have lesser section as the current necessary for the instrument is much lower than that of the shunt. Infact , it is not so much a question of the shunt being parallel with the instrument as the instrument deriving from the clamps of the shunt, of which it utilizes the drop in voltage, withdrawing a part of the current of the circuit, proportionate with the total current. TECHNICAL CHARACTERISTICS STANDARDS Electrical characteristics: CENELEC HD 233, CEI 13-6, IEC 51, VDE 0410, BS 89, C 42-100 Safety regulations: CENELEC HD 215, CEI 13-10, IEC 414, DIN 57410, BS 5458, C 42-010 Dimensions DIN 43703 Body: Brass OT58 - UNI 4892 Derivation with Manganina 43 Accessories: zinc-iron 8.8 TEMPERATURES Referred temperature: 20°C ± 10°C respecting the precision of their class Working temperature: -25°C ÷ +60°C Storage temperature: -40°C ÷ +80°C Temperature's coefficient: 0,002% for each °C % VARIATION OF RESISTANCE RESISTANCE OF MANGANINE / TEMPERATURE MATERIALS + 0,04 + 0,02 0 - 0,02 - 0,04 20 30 40 50 60 70 80 TEMPERATURE °C HUMIDITY Relative humidity of the ambient ≤ 95% PRECISION Class 0,5 OVERLOAD 1,2 In continuously 10 In for 5 seconds up to 250A 5 In for 5 seconds from 300 to 2000A 2 In for 5 seconds from 2500 to 6000A GENERAL Standard application: 60 mV and 150 mV The 60mV shunts are used with a maximum load of 0,25 ohm ; in the case of greater loads or long connection cables, the 150mV shunts should be used. Standards require the following primary values: 1 - 1,5 - 2,5 - 4 - 6 - 10 - 15 - 25 - 40 - 60 - 100 - 150 - 250 - 400 - 600 - 1000 - 1500 - 2500 4000 - 6000 - 10000 - 15000 A. Primary values different from the standard can be manufactured on request. To ensure the unit functions perfectly Revalco insists the following points are observed: 1. They can be fitted in either a horizontal or vertical position (if horizontal there is a greater dissipation of heat) 2. The contact surface must be completely used. 3. The contact surface must be clean; after connecting, cover with special grease. 4. The screws and bolts must be perfectly tightened. 5. The shunts must be sufficiently ventilated. Due the fact that the shunts are not insulated, it is better to protect them against accidental contacts. CODES LEGEND Code SH1K0A60MV identify a 1000A/60mV shunt Code SH1K5A60MV identify a 1500A/60mV shunt Code SH10KA60MV identify a 10000A/60mV shunt Code SH1K2A150MV identify a 1200A/150mV shunt Code SH5K0A60MV identify a 5000A/60mV shunt 25 app fotovoltaici 2010 GB:Contatori 08/10/10 12:56 Pagina 26 DIMENSIONS in mm secondary 60 mV SH1A60MV ÷ SH25A60MV Fixing packs: 2 screws M5x8 DIN 933 + 2 screws M5x12 DIN 933 + 4 washers M5 DIN 125A weight: 0,11 Kg SH30A60MV ÷ SH200A60MV Fixing packs: 2 screws M5x8 DIN 933 + 2 screws M8x16 DIN 933 + 2 washers M5 DIN 125A + 2 washers M8 DIN 125A Weight: 0,14 Kg SH250A60MV ÷ SH350A60MV Fixing packs: 2 screws M5x8 DIN 933 + 2 screws M12x40 DIN 933 + 2 nuts M12 DIN 934 + 2 washers M5 DIN 125A + 2 washers M12 DIN 125A + 2 grower washers M12 DIN 127B Weight: 0,53 Kg SH400A60MV ÷ SH700A60MV Fixing packs: 2 screws M5x8 DIN 933 + 2 screws M16x45 DIN 933 + 2 nuts M16 DIN 934 + 2 washers M5 DIN 125A + 2 washers M16 DIN 125A + 2 grower washers M16 DIN 127B Weight: 0,80 Kg SH750A60MV ÷ SH1K0A60MV Fixing packs: 2 screws M5x8 DIN 933 + 2 screws M20x50 DIN 933 + 2 nuts M20 DIN 934 + 2 washers M5 DIN 125A + 2 washers M20 DIN 125A + 2 grower washers M20 DIN 127B Weight: 1,40 Kg 26 secondary 150 mV SH1A150MV ÷ SH25A150MV Fixing packs: 2 screws M5x8 DIN 933 + 2 screws M5x12 DIN 933 + 4 weight M5 DIN 125A Peso: 0,11 Kg SH30A150MV ÷ SH200A150MV Fixing packs: 2 screws M5x8 DIN 933 + 2 screws M8x16 DIN 933 + 2 washers M5 DIN 125A + 2 washers M8 DIN 125A Weight: 0,20 Kg SH250A150MV ÷ SH350A150MV Fixing packs: 2 screws M5x8 DIN 933 + 2 screws M12x40 DIN 933 + 2 nuts M12 DIN 934 + 2 washers M5 DIN 125A + 2 washers M12 DIN 125A + 2 grower washers M12 DIN 127B Weight: 0,65 Kg SH400A150MV ÷ SH700A150MV Fixing packs: 2 screws M5x8 DIN 933 + 2 screws M16x45 DIN 933 + 2 nuts M16 DIN 934 + 2 washers M5 DIN 125A + 2 washers M16 DIN 125A + 2 grower washers M16 DIN 127B Weight: 0,95 Kg SH750A150MV ÷ SH1K0A150MV Fixing packs: 2 screws M5x8 DIN 933 + 2 screws M20x50 DIN 933 + 2 nuts M20 DIN 934 + 2 washers M5 DIN 125A + 2 washers M20 DIN 125A + 2 grower washers M20 DIN 127B Weight: 1,55 Kg app fotovoltaici 2010 GB:Contatori 08/10/10 12:56 Pagina 27 DIMENSIONS in mm secondary 60 mV SH1K2A60MV ÷ SH1K5A60MV Fixing packs: 2 screws M5x8 DIN 933 + 4 screws M16x45 DIN 933 + 4 nuts M16 DIN 934 + 2 washers M5 DIN 125A + 4 washers M16 DIN 125A + 4 grower washers M16 DIN 127B Weight: 1,90 Kg SH2K0A60MV ÷ SH2K5A60MV Fixing packs: 2 screws M5x8 DIN 933 + 4 screws M20x50 DIN 933 + 4 nuts M20 DIN 934 + 2 washers M5 DIN 125A + 4 washers M20 DIN 125A + 4 grower washers M20 DIN 127B Weight: 2,75 Kg SH4K0A60MV Fixing packs: 2 screws M5x8 DIN 933 + 4 screws M20x60 DIN 933 + 4 nuts M20 DIN 934 + 2 washers M5 DIN 125A + 4 washers M20 DIN 125A + 4 grower washers M20 DIN 127B Weight: 4,10 Kg SH5K0A60MV ÷ SH6K0A60MV Fixing packs: 2 screws M5x8 DIN 933 + 6 screws M20x75 DIN 933 + 6 nuts M20 DIN 934 + 2 washers M5 DIN 125A + 6 washers M20 DIN 125A + 6 grower washers M20 DIN 127B Weight: 9,00 Kg secondary 150 mV SH1K2A150MV ÷ SH1K5A150MV Fixing packs: 2 screws M5x8 DIN 933 + 4 screws M16x60 DIN 933 + 4 nuts M16 DIN 934 + 2 washers M5 DIN 125A + 4 washers M16 DIN 125A + 4 grower washers M16 DIN 127B Weight: 2,20 Kg SH2K0A150MV ÷ SH2K5A150MV Fixing packs: 2 screws M5x8 DIN 933 + 4 screws M20x60 DIN 933 + 4 nuts M20 DIN 934 + 2 washers M5 DIN 125A + 4 washers M20 DIN 125A + 4 grower washers M20 DIN 127B Weight: 3,10 Kg SH4K0A150MV Fixing packs: 2 screws M5x8 DIN 933 + 4 screws M20x75 DIN 933 + 4 nuts M20 DIN 934 + 2 washers M5 DIN 125A + 4 washers M20 DIN 125A + 4 grower washers M20 DIN 127B Weight: 4,65 Kg SH5K0A150MV ÷ SH6K0A150MV Fixing packs: 2 screws M5x8 DIN 933 + 6 screws M20x75 DIN 933 + 6 nuts M20 DIN 934 + 2 washers M5 DIN 125A + 6 washers M20 DIN 125A + 6 grower washers M20 DIN 127B Weight: 9,00 Kg 27 Kazakhstan Gost Russia Underwriters Laboratories Inc. USA Via Giorgio Stephenson, 90 - 20157 MILANO ITALY Telephone ++39 02.39002153 - Fax ++39 02.39002207 E-mail: info@revalco.it - Web site: www.revalco.it Revalco® is a trade mark - Made in Italy 28 ® 55DEAPFV-GB Ediz. 2010.01.GB - Validity of the catalogue: until the release of a new edition which cancels and replaces the previous one app fotovoltaici 2010 GB:Contatori 08/10/10 12:56 Pagina 28