Analog Panelmeters Do not risk your safety! www.sigmaelektrik.com ANALOG PANELMETERS ANALOG G Analog Panelmeters ANALOG PANELMETERS Features • • • • • For measurement of AC currents and voltages Good read-out survey on larger distance Exchangeable dial Resistance to mechanical vibrations Protective cover for terminals Technical Specifications Description Movement Type Accuracy Self Consumption Operating Voltage Test Voltage Construction & Desing Scale Glass Faceplate Mounting Fasteners/Clamps Temperature Conditions SA96 SA72 Moving iron meter of 90° deflection with interchangeable scale facility Moving iron spring-mounted jewel bearing suspencion ±1.5% of full scale as per EN 60051 (IEC51) Ammeters (upto 5A AC) ≤ 0.6VA; Voltmeters (upto 500V AC) ≤ 5VA 600V RMS max. 2.5KV for 1 minute at 50 Hz According to IEC51 According to DIN 43802 Flat Glass. Ergonomic easy mountable clamps and nuts for easy installation on Switchboards Panles, Mosaics etc. - 10 °C to + 55 °Ci RH < 90% (Operating) and -20 °C to + 70 °C, RH < 90% (Storage) EN60051 (IEC51) www.sigmaelektrik.com 111 ANALOG PANELMETERS Analog Panelmeters ACMIDPAV Regulations and Standards Our meters and indicator/controllers comply with the regulations of the European Guidelines 73/23/EWG and 89/336/EVG. This is confirmed bby the compliance with the following standards: IEC/EN 61010-1/A2.VDE 0411-1/A1(Safety Regulations) IEC 60 051/EN 60 051/DIN EN 60051 (Meters with cale Display) EN 50 081-2:1993 EMC (Emitted Interference, Industries) EN 50 082-2:1995 EMC (Emitted Resistance, Industries) Given below are the most important regulations for the fabrication and the required properties of electrical meters. Terminal Protection Full sized polycarbonate back cover to provide protection against accidental contact (hand and fingers) acc. to VDE 0410, Safety Precautions 1. Instruments with damaged bezels or window glasses must be disconnected from the mains. 2. The back cover must be snapped into place after connector wires have been clamped for protection against accidental contact. 3. Scales may only be replaced under voltage-free conditions. 4. Bezels and window glasses may only be replaced under voltage-free conditions. www.sigmaelektrik.com 112 ANALOG PANELMETERS Analog Panelmeters Effects of Vibration and Shock Unless otherwise specified. class 1 and higher measuring instruments and Accessories must withstand the following shock and vibration test. To which they are subjected during the course of type testing: Vibration Test Vibration testing must be performed with the following specifications: - Sweep frequency range: 10 Hz - 55 Hz - 10 Hz - Wave amplitude: 0.15 mm (corresponds to 1.5 g at 50 Hz) - Number of sweep cycles:5: - Sweep velocity 1 octave per minute The vibration plane is vertical and the measuing instrument is mounted to the vibration table in its usual operating positions. Connections Dimensions Type A B C D E F 96x96 72x72 96 72 91 67 90 66 5.5 5.5 65 65 43 43 www.sigmaelektrik.com 113 ANALOG PANELMETERS Analog Panelmeters Insulation Voltage 2 kV for one minute between mechanism and casing, and between electrically insulated terminals. Vibration and Shock Resistance Our measuring instruments comply with requirements per DIN EN 60051-1 Model Vibration Test Shock Test Standard 10 Hz-55 Hz-10 Hz 0,15 mm [1.5 g at 50 Hz] 147 m/s2 [15 gn] 11 ms Excessive Stress 5 Hz-55 Hz-5 Hz 0.25 mm [2.5 g at 50 Hz] 294 m/s2 [30 gn] 11 ms Exchanging Of Scales Press the cover, on top of the instrument, in the direction of the arrow and extract the scale with a suitable toll. After exchanging the scale, carefully close the opening with the cover. Vibration and Shock Resistance Our measuring instruments comply with requirements per DIN EN 60051-1 The instrument must be disconnected during the Exchange Procedure. The exchangeable scale has a number of advantages: Quick and simple adaptation of the instrument to variable user technical requirements shorter delivery time allows flexible planning Ordering Data: • • • Instrument type Measuring range and scale Transmission ratio of instrument transformer. www.sigmaelektrik.com 114 ANALOG PANELMETERS Analog Panelmeters Ordering Type Description Specifications Dim. mm Package pcs. Box pcs. Cat. Number SA 96A Ammeter 30 A directly measurement 96x96 1 60 SA96A-D030 SA 96A Ammeter 50 A directly measurement 96x96 1 60 SA96A-DO50 SA 96A Ammeter 100 A directly measurement 96x96 1 60 SA96A-D100 SA 96A Ammeter *X/5 with CT 96x96 1 60 *SA96A-X SA 72A Ammeter 30 A directly measurement 72x72 1 100 SA72A-D030 SA 72A Ammeter 50 A directly measurement 72x72 1 100 SA72A-D050 SA 72A Ammeter 100 A directly measurement 72x72 1 100 SA72A-D100 SA 72A Ammeter *X/5 with CT 72x72 1 100 * SA72A-X SA 96A Voltmeter 0-500 V AC 96x96 1 60 SA96V-0500 SA 96A Voltmeter 0-250 V AC 96x96 1 60 SA96V-0250 SA 72A Voltmeter 0-500 V AC 72x72 1 100 SA72V-0500 SA 72A Voltmeter 0-250 V AC 72x72 1 100 SA72V-0250 www.sigmaelektrik.com 115 Digital Instruments Do not risk your safety! www.sigmaelektrik.com DI Digital Instruments Universal Electronic Ammeter Digital ammeter is used to measure the AC current that goes the meter on its ring circuit. It also can be used in other working condition that is on the purpose of current measuring. The max value of the instantaneous conveyanoc current should not ezceed 5A. The transforming rate of the can be set from 1/5A to 5000/5 with the panel pushbutton. When the power sutting over, the class value set can be kept in the meter and the meter can be working on this condition. The working power supply input terminals(1-2) and the measuring signal connection terminals (3-4)are on the back board of the meter and the display screen is on the font panel. Setting Of Current Transformer Ratio: 1. Press the key and then display screen will indicate the current value. 2. Press the ADD key (upwelling) or press the DOWN key (down welling) and select the needed rate. 3. After select the rate, when press the set key, the display screen will be dark for one time and the rate will be kept in the meter automatically. 4. Attention: When press the button, the time must exceed 3 minutes or the operation will be of no effect. A SET SİGMA Warning: • A switch or circuit breaker must be connected between the network and the auxiliary supply input of device • Connected switch or circuit breaker must be in close proximity to the device • Connected switch or circuit breaker must be marked as the disconnecting device for the equipment • The type of used fuse must be FF type and the current of the used fuse must be 1A www.sigmaelektrik.com 118 SV 96 A DI Digital Instruments Dimensions SD96A Control Panel Cut Out 73 mm 68 mm 92 mm 90 mm 90 mm 64 mm 90 mm 68 mm 92 mm SD72A 83 mm SD96A (96x96) (72x72) 66 mm 66 mm 76 mm SD96A 66 mm The Area Measurements on The Control Panel Wall Wall 73 mm 64 mm 90 mm 66 mm 83 mm 76 mm SD96A SD72A 50 mm 50 mm *Warning: No need of a vantilator in the installation area Connection Diagram Technical Data: Auxiliary Supply (Un) : 230VAC Operating Range : (0.9-1.1)x Un Operating Frequency : 50/60Hz. Measuring Range : 0-5A Measurement Category: CAT III Class SD72A Amperemeter Amperemeter 4 3 : 1%+1 digit [(10%-100%)Xfull scale] o o Ambient Temperature : -5 C;+50 C Display SD96A 2 1 4 3 2 1 1A Measuring Input L N Measuring Input : Red LED Display Please check the device label for proper value www.sigmaelektrik.com 119 DI Digital Instruments Digital Voltmeter Digital voltmeter is used to measure the AC voltage that goes through the meter on its ring circuit lt also can de used in other working condition that is on the purpose of voltage measuring. The max value of the instantaneous conveyance voltage should not exceed 600V The working power supply input terminals (3-4) and the measuring signal connection terminals (1-2) are on the back board of the meter and the display screen is on the front panel. Precautions For Installation And Safe Use • Failure to follow those instruction will result in death or serious injury • Disconnect all power before working on equipment. • When the device is connected to the network, do not remove the front panel. • Do not try to clean the device with so/vent or the like. Only clean the device with a dried cloth. • Verify correct terminal connections when wiring. • Electrical equipment should be serviced only by your compedent seller. No responsibility is assured by SIGMA A.S. orany of its subsidiaries for any consequences arising out of the use of this metenal. Warning: • A switch or circuit breaker must be connected between the network and the auxiliary supply input of device • Connected switch or circuit breaker must be in close proximity to the device • Conencted switch or circuit breaker must be marked as the disconnecting device for the equipment www.sigmaelektrik.com 120 V SİGMA SV 96 V DI Digital Instruments Control Panel Cut Out Dimensions SD96V 73 mm 90 mm 68 mm 92 mm 90 mm 90 mm 64 mm 92 mm SD72V 83 mm SD96V SD96V (96x96) (72x72) 66 mm 66 mm 76 mm 68 mm 66 mm Connection Diagram SD96V Voltmeter 4 3 SD72V Voltmeter 2 1 4 3 2 1 1A Measuring Input L N 1A Measuring Input L N Technical Data: Auxiliary Supply (Un) : 220VAC Operating Range : (0.9-1.1)x Un Operating Frequency : 50/60Hz. Measuring Range : 0-600V~ Measurement Category : CAT III Class : 1%+1 digit [(10%-100%)Xfull scale] Ambient Temperature : -5°C;+50°C Display : Red LED Display *Please check the device label for proper value www.sigmaelektrik.com 121 DI Digital Instruments Ordering Digital AC Ammeter Type Description Spcifications Dim. mm Pacage pcs. Box pcs. Cat Number. SD 96A Ammeter 1-5000/5A with CT 96x96 1 60 SD96A-5000 SD 72A Ammeter 1-5000/5A with CT 72x72 1 100 SD72A-5000 Digital AC Voltmeter www.sigmaelektrik.com 122 Type Description Spcifications Dim. mm Pacage pcs. Box pcs. Cat Number. SD 96V Voltmeter 0-500 V AC 96x96 1 60 SD96V-0600 SD 72V Voltmeter 0-600 V AC 72x72 1 100 SD72V-0600 I D Do not risk your safety! VİTAMİN NOVA 0212 507 18 31 - 61 Do not risk your safety! Ekşioğlu Mah. Yeni Şile Cad. No:40 34794 Alemdağ - Çekmeköy / İstanbul / TURKEY Phone: +90 216 429 72 01 (pbx) Fax : +90 216 484 41 01 sigma@sigmaelektrik.com www.sigmaelektrik.com ISO 9001 : 2000 Made in