cop catalistino AGENTI GB in A4:cop generale gb corretta 20/10/10 12:28 Pagina 1 Prices list 2010 01 listino GB analogici prezzi ITA:listino ITA 15/11/10 16:11 Pagina 2 INDEX ANALOGUE INSTRUMENTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Voltmeters ........................................................................................................................................................................................................ Ammeters ......................................................................................................................................................................................................... Frequencymeters ............................................................................................................................................................................................ Tachometer indicators / Sequency meters / Sinchronoscopes / Power factor meters ............................................................................ Wattmeters and Varmeters ............................................................................................................................................................................. Single phase insulation indicators ................................................................................................................................................................ Accessories ..................................................................................................................................................................................................... Switches ........................................................................................................................................................................................................... Hour run meters / Impulse counters ............................................................................................................................................................. DIGITAL INSTRUMENTS TABLE 4 4 6 10 11 12 13 14 15 16 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17-18 DIGITAL SWITCHBOARD INSTRUMENTS - STANDARD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Voltmeters, Ammeters and Frequencymeters (depth 82 mm) .................................................................................................................... 19 DIGITAL SWITCHBOARD INSTRUMENTS - TRUE RMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 Ammeters 5A, Ammeters 60mV and Voltmeters (reduced depth 53 mm) ................................................................................................. 20 DIGITAL SWITCHBOARD INSTRUMENTS - TRUE RMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 Voltmeters 500V or 100V (depth 82 mm) ....................................................................................................................................................... Voltmeters 10V or 1V ..................................................................................................................................................................................... Voltmeters 600VAC and Voltmeters 800VDC ............................................................................................................................................... Ammeters 5A (1A) or 60mV (depth 82 mm) .................................................................................................................................................. Milliammeters 1mA/5mA/10mA/20mA/4-20mA and Frequencymeters (depth 82 mm) ............................................................................. Double single phase and Triple three phase instruments (depth 82 mm) ................................................................................................ Bargraph indicators / LED indicators ............................................................................................................................................................ 21 22 23 24 25 26 27 DIGITAL MODULAR INSTRUMENTS - TRUE RMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 Voltmeters ........................................................................................................................................................................................................ 27 Voltmeters 10V or 1V and Ammeters ............................................................................................................................................................. 28 Milliammeters 1mA/5mA/10mA/20mA/4-20mA, Frequencymeters and Double single phase / three phase instruments .................... 29 NETWORK ANALIZERS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 ANALOGUE OUTPUTS MODULES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 MULTIFUNCTION INSTRUMENTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 LED - True RMS - Single phase and Three phase ........................................................................................................................................ 30 LED - Standard version .................................................................................................................................................................................. 31 LCD - True RMS - Three phase ...................................................................................................................................................................... 31 COMPUTER INTERFACES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 MULTIFUNCTION INSTRUMENTS TABLE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 ENERGY kWh METERS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 Single-phase DC kWhmeters / Single-phase AC Active Energy / Three-phase Active Energy ................................................................ 38 Three-phase Reactive Energy ......................................................................................................................................................................... 39 KWh meters with minimum load threshold and enabling for hour-meter certifiable (fiscal use) .......................................................... 39 INDUCTION kWh METERS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 SEALABLE TERMINALS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 UTF CERTIFICATIONS / CUSTOM AGENCY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 RECORDERS OF IMPULSES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 EARTH LEAKAGE RELAIS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41 ADAPTER TOROIDAL CURRENT TRANSFORMERS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41 TOROIDAL CURRENT TRANSFORMERS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42 INSULATION CONTROL RELAY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42 PRICES EXPRESSED IN EURO. ALL PRICES QUOTED ARE NET AND DO NOT INCLUDE ANY CARRIAGE COSTS 01 listino GB analogici prezzi ITA:listino ITA 15/11/10 16:11 Pagina 3 MEASUREMENT TRANSDUCERS - TRUE RMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42 Current / Voltage / Frequency / Single-phase Active Power / DC Line Power transducers ..................................................................... 42 MEASUREMENT TRANSDUCERS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43 Current and Voltage transducers / DC current and voltage transducers 1DIN ........................................................................................ 43 Power factor / Frequency / Active and Reactive / Active and Reactive +RS485 transducers ................................................................. 44 SURGE ARRESTERS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45 EQUIPMENT FOR INDUSTRIAL AUTOMATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49 8 alarm channels set / Control and sequence phase relay.......................................................................................................................... 49 Min / Max single phase AC Current / Voltage relay ..................................................................................................................................... 49 Ammeters - Double threshold (min/max) ...................................................................................................................................................... 49 STABILIZED SUPPLIES / AUTOMATIC BATTERY CHARGERS / EMERGENCY SUPPLY . . . . . . . . . . . . . . . . . . 50 EQUIPMENT FOR CIVIL AUTOMATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 Alarms / Emergency static lamp .................................................................................................................................................................... Analogue, Digital and Astronomical time switches / Crepuscular switches / Multivoltage relays / Impulse relays ............................ Stairs light electronic relay / Modular current socket / Safety Bell transformers ..................................................................................... Bells / Electronic bell, 3 tones / Buzzers / Bells and Buzzers with transformer ....................................................................................... 50 51 52 53 EQUIPMENTS FOR GENERATING SET . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53 PROGRAMMABLE RECORDERS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54 ADJUSTABLE TRANSFORMERS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55 VARIABLE RESISTORS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57 CURRENT TRANSFORMERS - NANO SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58 MEASURING OR PROTECTION TRANSFORMERS RANGE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61 ADJUSTABLE / PROTECTION CURRENT TRANSFORMERS / PASSIVE SPLIT CURRENT SENSOR . . . . . . . 61 SPLIT CORE / OVERLOAD / TOROIDAL CURRENT TRANSFORMERS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62 SATURABLE TRANSFORMERS RANGE FOR THERMAL RELAYS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63 CURRENT TRANSFORMERS - MINI SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63 CURRENT TRANSFORMERS - SMALL SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64 CURRENT TRANSFORMERS - STANDARD SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66 PROTECTION / DOUBLE RATIO CURRENT TRANSFORMERS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68 DC OUTPUT 4/20 mA CURRENT TRANSFORMERS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69 DC OUTPUT 4/20 mA WITH EXTERNAL POWER SUPPLY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69 DC OUTPUT 0-20 mA AND 0-10V CURRENT TRANSFORMERS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70 HALL EFFECT CURRENT TRANSFORMERS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71 SUMMATION / RATIO CORRECTING CURRENT TRANSFORMERS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71 CURRENT TRANSFORMERS FOR ELECTRONIC USE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72 VOLTAGE TRANSFORMERS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72 BAR INSULATORS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73 SHUNTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73 ACCESSORIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73 MEDIUM VOLTAGE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74 INSTRUMENTS FOR RAIL-WAY AND NAVAL USE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78 SPECIAL EXECUTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79 CONDITIONS OF SALE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79 3 01 listino GB analogici prezzi ITA:listino ITA 15/11/10 16:11 Pagina 4 ANALOGUE INSTRUMENTS VOLTMETERS A.C. MOVING IRON SCALE PLATE 90° MODULAR VERSION SCALE PLATE 90° Class 1,5 Dimensions: 3 DIN modules SWITCHBOARD VERSION Class 1,5 Dimensions: 48x48, 72x72, 96x96, 144x144 mm ERIM Voltmeters direct input 6-10-15-25-40-60-100-150-250-300-400-500-600 VD Voltmeters input by means of V.T., scale plate included When ordering, please indicate the primary voltage value ...100V; ......110V 30,40 30,40 Voltmeters direct input 6-10-15-25-40-60-100-150-250-300 -400-500-600 VD Voltmeters input by means of V.T., scale plate included. When ordering, please indicate the primary voltage value ...100V; ......110V WITH INCORPORATED SWITCH ERI48 ERI72 ERI96 ERI144 30,50 25,45 26,60 43,15 30,50 25,45 26,60 43,15 SWITCHBOARD VERSION Class 1,5 Instruments provided with switch, low voltage, for three phase-phase and three phase-neutral voltage L1N-L2N-L3N / L1L2-L2L3-L3L1 ERI72C 35,55 35,55 Voltmeters direct input 6-10-15-25-40-60-100-150-250-300-400-500-600 VD Voltmeters input by means of V.T., scale plate included. When ordering, please indicate the primary voltage value ...100V; ......110V WITH LED FREQUENCY METER ERI96C 37,80 37,80 SWITCHBOARD VERSION These instruments consint of the combination of a analogue voltmeter with 500V end scale value, and a three leds electronic circuit for the reading of the frequency. Principally used in small generating sets where more space is saved. Accuracy Class 1 Dimensions 72x72 mm ERI72VH 68,00 Voltage 500V Frequency 48-50-52 Hz DOUBLE VOLTMETER SWITCHBOARD VERSION These instruments consist of two equipments mounted on a common axis permitting the two pointers indicating on one graduation. In this way there is the immediate comparison of the parallel adjustment. The moving coil system reduces drastically the burden and permits linear graduations. Accuracy Class 1,5 Dimensions 96x96 mm ERI96D 185,40 Capacity 2x500V WITH 2 THRESHOLDS ALARM SWITCHBOARD VERSION Standard range: 600V direct input, different ranges on request Relays data: max break power with resistive load 2kVA (8A,250V) ERIC96V=AL 1 (MIN) AL 2 (MAX) ERIC96VMA=AL 1 (MAX1) AL 2 (MAX2) ERIC96VMI=AL 1 (MIN1) AL 2 (MIN2) ERIC96VMM=AL 1 (MAX-) AL 2 (MAX+) Setting by 2 front buttons Delayed alarm time from 1 to 15 seconds, selectable by minidip situated under the white frame Class 1,5 Dimensions 96x96 mm ERIC96V 257,50 Auxiliary power supply 230 VAC Direct insertion, auxiliary power supply 24 VAC Direct insertion, auxiliary power supply 110 VAC Direct insertion, DC auxiliary supply ZEROVOLTMETER 4 ERIC96V110 ERIC96VP6 288,40 288,40 339,90 SWITCHBOARD VERSION These instruments consist of moving coil movements with internal rectifier which can be used to replace the Sinchronoscope in the synchronizing of two generators or one generator in the network. When the two voltages to be synchronized are the same, the instrument indicates “zero”. Accuracy Class 1,5 Dimensions 48x48, 72x72, 96x96, 144x144 mm Standard capacity from 0 to 500V extended to 800V ERIC96V24 90˚ Scale plate 240˚ Scale plate ERZ48 77,25 ERZ72 77,25 ERZ96 77,25 ERZ144 93,75 ERZL48 133,90 ERZL72 133,90 ERZL96 133,90 01 listino GB analogici prezzi ITA:listino ITA 15/11/10 16:11 Pagina 5 VOLTMETERS WITH SUPPRESSED ZERO SWITCHBOARD VERSION These instruments consist of moving coil movements and internal rectifier which are used to determine very precisely the normal value of the sinusoidal alternating voltage Measuring ranges between 90 to 110% approximately of the voltage Accuracy Class 1,5 Dimensions 48x48, 72x72, 96x96, 144x144 mm Standard capacity 0-90/110V, 0-100/120V, 0-200/240V, 0-340/420V 90˚ Scale plate 240˚ Scale plate ERZS48 91,15 ERZS72 91,15 ERZS96 91,15 ERZS144 111,25 ERZSL48 129,80 ERZSL72 129,80 ERZSL96 129,80 PANEL VERSION Accuracy Class 1,5 Diameter 55 mm Direct input 6-10-15-25-40-60-100-150-250-300-400-500-600 VD Input by means of V.T., scale plate included ...100V; ......110V When ordering, please indicate the primary voltage value Black frontal jig Rectangular black frontal jig EMI55M 24,20 A55NE Diameter 70 mm A55RE EMI70M 26,25 24,20 A70N A70R 26,25 1,80 1,90 4,15 4,25 MOVING COIL FOR ALTERNATING CURRENT SWITCHBOARD VERSION Accuracy Class 1,5 Dimensions 48x48, 72x72, 96x96, 144x144 mm Version with internal rectifier 90˚ Scale plate Direct input 6-10-15-25-40-60-100-150-250-300-400-500-600 VD Input by means of V.T., scale plate included When ordering, please indicate the primary voltage value ...100V; ......110V 240˚ Scale plate ERR48 72,10 ERR72 72,10 ERR96 72,10 ERR144 84,45 ERIL48 122,55 ERIL72 122,55 ERIL96 122,55 72,10 72,10 72,10 84,45 122,55 122,55 122,55 PROFILE VERSION Accuracy Class 1,5 Version with internal rectifier Horizontal version: dimensions 24x96 mm Vertical version: dimensions 96x24 mm Direct input 6-10-15-25-40-60-100-150-250-300-400-500-600 VD Input by means of V.T., scale plate included. When ordering, please indicate the primary voltage value ...100V; ......110V ERPI24/O 108,15 108,15 ERPI24/V 108,15 108,15 MOVING COIL FOR DIRECT CURRENT MODULAR VERSION Class 1,5 Dimensions: 3 DIN modules Millivoltmeters direct input Voltmeters direct input 60......600 mVD 1-1,5-2,5-4-5-6-10-15-20-25-40-60-100-150-250-300-400-500-600 VD ERCM 50,45 50,45 SWITCHBOARD VERSION Class 1,5 Dimensions 48x48, 72x72, 96x96, 144x144 mm 90˚ Scale plate Millivoltmeters direct input Voltmeters direct input 60-100-150-250-400-600 mVD 6-10-15-25-40-60-100-150-250-300-400-500-600 VD ERC48 48,10 51,50 ERC72 48,10 51,50 ERC96 48,10 51,50 ERC144 63,35 63,35 240˚ Scale plate ERCL48 122,50 122,50 ERCL72 103,00 103,00 ERCL96 103,00 103,00 5 01 listino GB analogici prezzi ITA:listino ITA 15/11/10 16:11 Pagina 6 WITH 2 THRESHOLDS ALARM SWITCHBOARD VERSION Standard range: 1-10-50-100-300-600VD direct input, different ranges on request Relays data: max break power with resistive load 2kVA (8A,250V) ERCC96V=AL 1 (MIN) AL 2 (MAX) ERCC96VMA=AL 1 (MAX1) AL 2 (MAX2) ERCC96VMI=AL 1 (MIN1) AL 2 (MIN2) ERCC96VMM=AL 1 (MAX-) AL 2 (MAX+) Setting by 2 front buttons Delayed alarm time from 1 to 15 seconds, selectable by minidip situated under the white frame Class 1,5 Dimensions 96x96 mm ERCC96V 257,50 Auxiliary power supply 230 VAC Direct insertion, auxiliary power supply 24 VAC Direct insertion, auxiliary power supply 110 VAC Direct insertion, DC auxiliary supply ERCC96V24 ERCC96V110 ERCC96VP6 288,40 288,40 339,90 PANEL VERSION Class 1,5 Diameter 55 mm Millivoltmeters direct input 60-100-150-250-400-600 mVD Voltmeters direct input 1-1,5-2,5-4-6-10-15-25-40-60-100-150-250-300-400-500-600 VD Black frontal jig Rectangular black frontal jig EMC55M 38,60 A55NE A55RE 38,60 Diameter 70 mm EMC70M 39,15 A70N A70R 39,15 1,80 1,90 4,15 4,25 PROFILE VERSION Class 1,5 Horizontal version: dimensions 24x96 mm Vertical version: dimensions 96x24 mm Millivoltmeters direct input Voltmeters direct input 60.......300 mVD 1-1,5-2,5-4-6-10-15-30-40-50-60-80-100-150-200-250-300-400-500-600 VD ERPC24/O 108,15 108,15 ERPC24/V 108,15 108,15 AMMETERS INTERCHANGEABLE SCALE PLATE The DIN standards ranges (to be communicated when ordering) are: 1-1,2-1,5-2-2,5-3-4-5-6-8-10-15-20-25-30-40-50-60-75-80-100-120-150-200-250-300-400-500-600-800-1000-1,2k-1,5k-2k-2,5k-3k-4k-5k-6k A A.C. MOVING IRON MAXIMUM DEMAND AMMETERS SWITCHBOARD VERSION This type of instrument is used to check long over loading in transformers, cable and substations. They also make it possible to check, economically, distribution networks in the place of very costly recorders. A special sealable knob makes it possible to zero the general indicator. The capacity is 6A for use with .../5A C.T. and maximum over loading of 20%. On request instruments can be provided with a capacity of 1,2A for use with C.T. .../1A. Accuracy Class 3 Dimensions 72x72, 96x96 mm Input by means of C.T., secondary 5A, without scale plate Input by means of C.T., secondary 5A, without scale plate Input by means of C.T., secondary 1A, without scale plate Input by means of C.T., secondary 1A, without scale plate Interchangeable scale plate. When ordering, please indicate the primary current value 15 min 8 min 15 min 8 min A1 ERB48 55,50 55,50 55,50 55,50 ERB72 54,35 54,35 54,35 54,35 COMBINED MAXIMUM DEMAND AMMETERS ERB96 55,50 55,50 55,50 55,50 ESB48 ESB72 ESB96 3,20 3,20 3,20 SWITCHBOARD VERSION These instruments exploit the combining of thermal equipment with moving iron equipment, permitting deferred reading (typical of bimetallic systems) combined with instantaneous reading of the current values. The capacity is 6A for moving iron connection .../5A C.T. On request instruments can be provided with a capacity of 1,2A for connection to a 1A C.T. while the normal over loading in the moving iron system is of 100% and 20% in the bimetallic system. Moving iron system Class 1.5 - Bimetal system Class 3 Dimensions 72x72, 96x96 mm Input by means of C.T., secondary 5A, without scale plate Input by means of C.T., secondary 5A, without scale plate Input by means of C.T., secondary 1A, without scale plate Input by means of C.T., secondary 1A, without scale plate Interchangeable scale plate. When ordering, please indicate the primary current value 6 15 min 8 min 15 min 8 min A1 ERBC72 93,30 93,30 93,30 93,30 ERBC96 94,50 94,50 94,50 94,50 ESBC72 ESBC96 4,35 4,35 01 listino GB analogici prezzi ITA:listino ITA 15/11/10 16:11 Pagina 7 90° SCALE PLATE MODULAR VERSION Class 1,5 Dimensions: 3 DIN modules ERIM 28,30 28,30 28,30 26,25 26,25 26,25 26,25 26,25 26,25 Direct input 1In ERIM 1-1,5-2,5-4-5-6-10-15-20-25-30 A1D Direct input 2In ERIM 1-1,5-2,5-4-5-6-10-15-20-25-30 A2D Direct input 5In ERIM 1-1,5-2,5-4-5-6-10-15-20-25-30 A5D Input by means of C.T., secondary 1A, without scale plate, 1In ERIM1A1 Input by means of C.T., secondary 1A, without scale plate, 2In ERIM1A2 Input by means of C.T., secondary 1A, without scale plate, 5In ERIM1A5 Input by means of C.T., secondary 5A, without scale plate, 1In ERIM5A1 Input by means of C.T., secondary 5A, without scale plate, 2In ERIM5A2 Input by means of C.T., secondary 5A, without scale plate, 5In ERIM5A5 Interchangeable scale plate for ERIM1A1 = A11, for ERIM1A2 = A21, for ERIM1A5 = A51, for ERIM5A1 = A15, for ERIM5A2 = A25, for ERIM5A5 = A55 90° SCALE PLATE ESIM 2,05 SWITCHBOARD VERSION Class 1,5 Dimensions 48x48, 72x72, 96x96, 144x144 mm Milliammeters 250-400-600-800-900mA direct input Direct input 1In ERI... 1-1,5-2,5-4-5-6-10-15-20-25-30 A1D Direct input 2In ERI... 1-1,5-2,5-4-5-6-10-15-20-25-30 A2D Direct input 5In ERI... 1-1,5-2,5-4-5-6-10-15-20-25-30 A5D Direct input 1In ERI... 1-1,5-2,5-4-5-6-10-15-20-25-30-40-50-60 A1D Direct input 2In ERI... 1-1,5-2,5-4-5-6-10-15-20-25-30-40-50-60 A2D Direct input 5In ERI... 1-1,5-2,5-4-5-6-10-15-20-25-30-40-50-60 A5D Input by means of C.T., secondary 1A, without scale plate, 1In ERI...1A1 Input by means of C.T., secondary 1A, without scale plate, 2In ERI...1A2 Input by means of C.T., secondary 1A, without scale plate, 5In ERI...1A5 Input by means of C.T., secondary 5A, without scale plate, 1In ERI...5A1 Input by means of C.T., secondary 5A, without scale plate, 2In ERI...5A2 Input by means of C.T., secondary 5A, without scale plate, 5In ERI...5A5 Interchangeable scale plate for ERI...1A1 = A11, for ERI...1A2 = A21, for ERI...1A5 = A51, for ERI...5A1 = A15, for ERI...5A2 = A25, for ERI...5A5 = A55 ERI48 30,50 30,50 30,50 30,50 27,30 27,30 27,30 27,30 27,30 27,30 ERI72 27,20 ERI96 28,65 ERI144 43,15 27,20 27,20 27,20 24,00 24,00 24,00 24,00 24,00 24,00 28,65 28,65 28,65 24,00 24,00 24,00 24,00 24,00 24,00 43,15 43,15 43,15 39,05 39,05 39,05 39,05 39,05 39,05 WITH INCORPORATED SWITCH ESI48 ESI72 ESI96 ESI144 3,20 3,20 3,20 4,15 SWITCHBOARD VERSION Class 1,5 Instruments provided with one pole switch, low voltage, for three current transformers L1-L2-L3 ERI72C ERI96C 35,55 37,80 Input by means of C.T., secondary 5A, 2In, scale plate included 1-1,2-1,5-2-2,5-3-4-5-6-8-10-15-20-25-30-40-50-60-75-80-100-120-150-200-250-300-400-500-600-800-1000-1,2-1,5k-2k-2,5k-3k-4k-5k-6k A25 WITH 2 THRESHOLDS ALARM SWITCHBOARD VERSION Standard range: 1-1,2-1,5-2-2,5-3-4-5-6-8-10-15-20-25-30-40-50-60-75-80-100-120-150-200-250-300-400-500-600-800-1000-1,2-1,5k-2k-2,5k-3k-4k-5k-6k Input by means of C.T. 5A (secondary 1A on request), different ranges on request Relays data: max break power with resistive load 2kVA (8A,250V) ERIC96A=AL 1 (MIN) AL 2 (MAX) ERIC96AMA=AL 1 (MAX1) AL 2 (MAX2) ERIC96AMI=AL 1 (MIN1) AL 2 (MIN2) ERIC96AMM=AL 1 (MAX-) AL 2 (MAX+) Setting by 2 front buttons Delayed alarm time from 1 to 15 seconds, selectable by minidip situated under the white frame Class 1,5 Dimensions 96x96 mm ERIC96A 257,50 Auxiliary power supply 230 VAC Direct insertion, auxiliary power supply 24 VAC Direct insertion, auxiliary power supply 110 VAC Direct insertion, DC auxiliary supply ERIC96A24 ERIC96A110 ERIC96AP6 288,40 288,40 339,90 PANEL VERSION Class 1,5 Milliammeters direct input 250-400-600-800-900 mA1D Ammeters direct input 1In 1-1,5-2,5-4-5-6-10-15-25-30-40-50-60 A1D Input by means of C.T., secondary 1A, 1In, scale plate included When ordering, please indicate the primary current value A11 Input by means of C.T., secondary 5A, 1In, scale plate included A15 When ordering, please indicate the primary current value Black frontal jig Rectangular black frontal jig Diameter 55 mm EMI55M 24,20 24,20 A55NE A55RE 24,20 Diameter 70 mm EMI70M 26,25 26,25 A70N A70R 26,25 24,20 26,25 1,80 1,90 4,15 4,25 7 01 listino GB analogici prezzi ITA:listino ITA 15/11/10 16:11 Pagina 8 MOVING COIL FOR ALTERNATING CURRENT SWITCHBOARD VERSION Accuracy Class 1,5 Dimensions 48x48, 72x72, 96x96, 144x144 mm Version with internal rectifier 90˚ Scale plate Microammeters direct input 100-150-250-400-600 µAD Milliammeters direct input 1-1,5-2,5-4-5-6-10-15-20-25-30-40-60-100-150-250-400-600-800-900 mAD Ammeters direct input 1-1,5-2,5-4-5 AD Input by means of C.T., secondary 1A, 1In, whitout scale plate 1A1 Input by means of C.T., secondary 5A, 1In, whitout scale plate 5A1 Interchangeable scale plate for ERR / ERIL 1A1 Interchangeable scale plate for ERR / ERIL 5A1 A11 A15 240 Scale plate ERR48 72,10 ERR72 72,10 ERR96 72,10 ERR144 84,45 ERIL48 122,55 ERIL72 122,55 ERIL96 122,55 72,10 72,10 69,00 69,00 72,10 72,10 69,00 69,00 72,10 72,10 69,00 69,00 84,45 84,45 82,40 82,40 122,55 122,55 122,55 122,55 122,55 122,55 122,55 122,55 122,55 122,55 122,55 122,55 ESR48 3,20 3,20 ESR72 3,20 3,20 ESR96 3,20 3,20 ESR144 4,15 4,15 ESR48 3,20 3,20 ESR72 3,20 3,20 ESR96 3,20 3,20 PANEL VERSION Class 1,5 Horizontal version: dimensions 24x96 mm Vertical version: dimensions 96x24 mm Version with internal rectifier Direct input 1In Input by means of C.T., secondary 1A, 1In, scale plate included. When ordering, please indicate the primary current value Input by means of C.T., secondary 5A, 1In, scale plate included. When ordering, please indicate the primary current value 0,5-1-1,5-2-2,5-5 A1D A11 A15 ERPI24/O 108,15 108,15 108,15 ERPI24/V 108,15 108,15 108,15 MOVING COIL FOR DIRECT CURRENT 90° SCALE PLATE MODULAR VERSION Class 1,5 Dimensions: 3 DIN modules Secondary 50mV or 75mV on request Microammeters direct input Milliammeters direct input 100-150-250-400-500-600 µAD 1.....600 mAD 4/20 mAD 1-1,5-2,5-4-5-6-10-15-20-25-30 AD .../60 mV 4/20 mA A60 mV 4/20 mA Ammeters direct input Millivoltmeters Input by means off shunt, secondary 60mV, without scale plate Milliammeters without scale plate Interchangeable scale plate ESCM60mV. When ordering, please indicate the primary current value Interchangeable scale plate ESCM4/20mA. When ordering, please indicate the primary current value ERCM 50,45 ESCM 50,45 50,45 48,40 48,40 2,05 2,05 SWITCHBOARD VERSION Class 1,5 Dimensions 48x48, 72x72, 96x96, 144x144 mm Secondary 50mV or 75mV on request 90˚ Scale plate 240° Scale plate ERC48 ERC72 ERC96 ERC144 ERCL48 ERCL72 ERCL96 55,40 55,40 55,40 55,40 55,40 55,40 55,40 55,40 122,55 122,55 113,30 113,30 113,30 113,30 48,10 48,10 48,10 48,10 122,55 113,30 113,30 55,40 45,85 55,40 45,85 55,40 45,85 55,40 45,85 122,55 119,35 113,30 110,10 113,30 110,10 ESC48 ESC72 ESC96 ESC144 ESCL48 ESCL72 ESCL96 3,20 3,20 3,20 4,15 3,20 3,20 3,20 Microammeters direct input 50-60-100-150-250-400-600-800-900 µAD Microammeters direct input 100-150-250-400-600-800-900 µAD Milliammeters 1-1,5-2,5-4-5-6-10-15-20-25-30-40-60-100-150-250-400-600-800-900 mAD 4/20 mA Ammeters direct input 1-1,5-2,5-4,6-10-15-25-40-60 AD Input by means off shunt, secondary 60mV, without scale plate .../60 mV Interchangeable scale plate ERC / ERCL 60mV When ordering, please indicate the primary current value 8 A60mV 01 listino GB analogici prezzi ITA:listino ITA 15/11/10 16:11 Pagina 9 WITH 2 THRESHOLDS ALARM SWITCHBOARD VERSION Milliammeters ranges: 1-20-4/20mA (other on request) Ammeters ranges: 1-1,2-1,5-2-2,5-3-4-5-6-8-10-15-20-25-30-40-50-60-75-80-100-120-150-200-250-300-400-500-600-800-1000-1,2k-1,5k-2k-2,5k-3k-4k-5k-6k Input by means of shunt 60mV, different ranges on request Relays data: max break power with resistive load 2kVA (8A,250V) ERCC96A=AL 1 (MIN) AL 2 (MAX) ERCC96AMA=AL 1 (MAX1) AL 2 (MAX2) ERCC96AMI=AL 1 (MIN1) AL 2 (MIN2) ERCC96AMM=AL 1 (MAX-) AL 2 (MAX+) Setting by 2 front buttons Delayed alarm time from 1 to 15 seconds, selectable by minidip situated under the white frame Class 1,5 Dimensions 96x96 mm ERCC96A 257,50 Auxiliary power supply 230 VAC Direct insertion, auxiliary power supply 24 VAC Direct insertion, auxiliary power supply 110 VAC Direct insertion, DC auxiliary supply ERCC96A24 ERCC96A110 ERCC96AP6 288,40 288,40 339,90 PANEL VERSION Class 1,5 Secondary 50mV or 75mV on request Microammeters direct input 50-60-100-150-250-400-500-600-800-900 µAD Milliammeters direct input 1-1,5-2,5-4-5-6-10-15-20-25-30-40-60-100-150-250-400-600-800-900 - 4/20 mAD Ammeters direct input 1-1,5-2,5-4-5-6-10-15-25-30-40-50-60 AD Input by means of shunt, secondary 60mV, scale plate included A60mV When ordering, please indicate the primary current value Black frontal jig Rectangular black frontal jig Diameter 55 mm EMC55M 38,65 A55NE A55RE 38,65 38,65 Diameter 70 mm EMC70M 39,15 A70N A70R 39,15 39,15 38,65 39,15 1,80 1,90 4,15 4,25 PROFILE VERSION Class 1,5 Horizontal version: dimensions 24x96 mm Vertical version: dimensions 96x24 mm Secondary 50mV or 75mV on request Microammeters direct input 25-50-100-150-200-250-500 µAD Milliammeters direct input 1-5-10-50-100-150-200-250-500-600 - 4/20 mAD Ammeters direct input 1-1,5-2-2,5-3-4-5 AD Input by means of shunt, secondary 60mV, scale plate included. When ordering, please indicate the primary current value A60mV ERPC24/O 108,15 108,15 108,15 108,15 ERPC24/V 108,15 108,15 108,15 108,15 9 01 listino GB analogici prezzi ITA:listino ITA 15/11/10 16:11 Pagina 10 FREQUENCYMETERS POINTER MODULAR VERSION Class 0,5 Dimensions 3 DIN modules Moving coil system with incorporated electronics Supply voltage: 110V, 230V, 400V (to be specify when ordering) Standard scale plate: 45/65 Hz (different capacities on request) Standard range 45/65 Hz POINTER SWITCHBOARD VERSION Class 0,5 Dimensions 48x48, 72x72, 96x96, 144x144 mm Moving coil system with incorporated electronics Supply voltage: 110V, 230V, 400V (to be specify when ordering) Standard scale plate: 45/65 Hz (different capacities on request) Standard range ERFM 96,80 90˚ Scale plate 45/65 Hz ERF48 89,35 ERF72 77,25 ERF96 80,85 ERF144 94,75 DOUBLE POINTER 240˚ Scale plate ERFL72 147,80 ERFL96 163,25 SWITCHBOARD VERSION These instruments consist of two equipments mounted on a common axis permitting the two pointers indicating on one graduation. In this way there is the immediate comparison of the parallel adjustment. The moving coil system reduces drastically the burden and permits linear graduations. Class 0,5 Dimensions 96x96 mm Standard range 2x45/65 Hz WITH 2 THRESHOLDS ALARM ERF96D 247,20 SWITCHBOARD VERSION Standard range: 45/65 Hz (other on request) Voltage input 100÷600V Relays data: max break power with resistive load 2kVA (8A,250V) ERFC96A=AL 1 (MIN) AL 2 (MAX) ERFC96AMA=AL 1 (MAX1) AL 2 (MAX2) ERFC96AMI=AL 1 (MIN1) AL 2 (MIN2) ERFC96AMM=AL 1 (MAX-) AL 2 (MAX+) Setting by 2 front buttons Delayed alarm time from 1 to 15 seconds, selectable by minidip situated under the white frame Class 1,5 Dimensions 96x96 mm Auxiliary power supply 230 VAC Direct insertion, auxiliary power supply 24 VAC Direct insertion, auxiliary power supply 110 VAC Direct insertion, DC auxiliary supply VIBRATING REEDS ERFC96A 278,10 ERFC96A24 ERFC96A110 ERFC96AP6 288,40 288,40 370,80 SWITCHBOARD VERSION Class 0,5 Dimensions 72x72, 96x96 Nominal voltages: 110V, 230V, 400V (to be specified when ordering) Standard range Standard range DOUBLE VIBRATING REEDS 45/55 Hz or 47/53 Hz - 11 reeds 55/65 Hz or 57/63 Hz - 11 reeds ERFV72 127,70 127,70 ERFV96 127,70 127,70 SWITCHBOARD VERSION Class 0,5 Dimensions 96x96 Nominal voltages: 2x110V, 2x230V, 2x400V (to be specified when ordering) Standard range Standard range 10 2x45/55 Hz or 2x47/53 Hz - 2x11 reeds 2x55/65 Hz or 2x57/63 Hz - 2x11 reeds ERFVD96 198,30 198,30 01 listino GB analogici prezzi ITA:listino ITA 15/11/10 16:11 Pagina 11 TACHOMETER INDICATORS POINTER SWITCHBOARD VERSION Accuracy Class 1,5 Dimensions 48x48, 72x72, 96x96, 144x144 mm When ordering, indicate the scale, unit of measurement, input voltage and number of revolutions. 90˚ Scale plate 240˚ Scale plate Tacho generator indicator (DC) ERCT48D 64,90 ERCT72D 64,90 ERCT96D 64,90 ERCT144D 73,10 ERCTL48D ERCTL72D ERCTL96D 118,45 118,45 118,45 Tacho alternator indicator (AC) ERCT48A 74,15 ERCT72A 74,15 ERCT96A 74,15 ERCT144A 84,45 ERCTL48A ERCTL72A ERCTL96A 118,45 118,45 118,45 SEQUENCY METERS ELECTRONIC MODULAR AND SWITCHBOARD VERSION These instruments, for alternating three-phase current, and are used when it is necessary to know whether the sequence of the phases of a three-phase line are correct or not. If the sequence is exact (L1-L2-L3), the green pilot light comes in; if not, the red pilot light will come on. Should one of the phases be missing, the two pilot lights will come on at the same time with a luminous intensity which will be half the original intensity. Accuracy Class 0,5 Dimensions 3DIN, 72x72 e 96x96 mm Single supply voltage from 150V to 600V 1RSM 83,45 ERS72 52,00 ERS96 55,10 SYNCHRONOSCOPES ELECTRONIC SWITCHBOARD VERSION These instruments are intended for measuring phase difference Δϕ between a bus-bar and a generator.They are provided with a synchronising check relay which enables switch-on of synchronisation when the set parameters are reached. These instruments are equipped with a circular display of phase angle which consists of 18 led’s.Momentary phase difference is displayed by led. Within synchronisation range (Δϕ=0° between -15°el and +15°el) resolution is increased to 5°el. If difference of frequency between input voltages exceeds 3Hz, three leds above FAST (fgen > frete) or SLOW (fgen < frete) inscription are alternately illuminated. A green SYNC. LED is illuminated when synchronisation conditions are made. A red ΔU led is illuminated when difference between voltages is above the set value or when the bus-bar voltage is lower then 80% of nominal value Un. In these instruments comparison of the input voltage of generator Ugen and net Unet method is used ,through and A/D converter of the microprocessor.The input voltages are galvanically insulated by a transformer and a microprocessor controls all the operations of the synchronoscope verifying the values of the input voltages coming from the A/D converter, determining the difference of phase (Δϕ) between generator and net. The synchronoscopes are provided with three potentiometers for settting conditions of a synchronisation relay switch-on at the instrument rear side: for setting permitted phase difference Δϕ, for setting permitted voltage difference ΔU, for a delay of synchronisation relay switch-on (DELAY). When phase difference and voltage difference between a generator and bus-bar for time of delay of synchronisation check relay are within the set limits, the synchronisation check relay is switched on for approx 150ms. In that time the SYNC. Led is illuminated as well. Dimensions 96x96 mm ERSI96 288,40 Nominal voltages 57, 100, 230, 400V (to be specified when ordering) Nominal voltages 57, 100, 230, 400V (to be specified when ordering) with frontal display for voltage and frequency visualization ERSI96D 319,30 POWER FACTOR METERS WITH INCORPORATED ELECTRONIC SWITCHBOARD VERSION Class 2,5 Dimensions 96x96 mm Standard capacity 0,5 - 1 - 0,5 cosϕ Nominal voltages: 110V, 230V, 400V (to be specified when ordering) Input current 5A 90˚ Scale plate ERFA96/1 235,85 Single phase Three phase, balanced load without neutral ERFA96/2 235,85 WITH EXTERNAL ELECTRONIC 240˚ Scale plate ERFAL96/1 ERFAL96/2 318,25 318,25 MODULAR AND SWITCHBOARD VERSION Dimensions 48x48, 72x72, 96x96, 144x144 mm for reading instruments; 6 DIN modules for transducers These instruments are made by an external transducer and an signal reader instrument Standard scale plate: 0,5 - 1 - 0,5 cosϕ Accuracy Class 1,5 90˚ Scale plate Single phase transducer, output 1mA Three phase, balanced load without neutral transducer, output 1mA DC reading instruments, input 1mA 1CORFP10 1CORFP20 336,80 DC reading instruments with 2 thresholds alarm, input 1mA 240˚ Scale plate ERCM ERC48 ERC72 ERC96 ERC144 ERCL48 ERCL72 ERCL96 50,45 48,10 48,10 48,10 63,35 118,95 103,00 103,00 336,80 ERCC96 360,50 11 01 listino GB analogici prezzi ITA:listino ITA 15/11/10 16:11 Pagina 12 WATTMETERS AND VARMETERS MULTISCALE FUNCTION By adopting a single instrument with an interchangeable scale and multi-voltage converter it is possible to obtain all of the capacities shown on the table below. It is necessary to select the input voltage on the accessory and to insert the scale corresponding to the current transformer. If for example there is a need for a monophase, 400V Wattmeter (Varmeter) with a C.T. ratio of 300/5A; the corresponding scale to insert into the instrument has a 120KW (KVAR) scale as highlighted in the table below. This function only applies if the input voltage is direct and not by means of a V.T. in which case calibration in the factory is prefered. Where it is necessary to take advantage of the multi-scale function, even if the input voltage derives from a V.T., eg: 1500/100V, it is necessary to determine the voltage constant by dividing the primary with the secondary 1500:100=15. In order to select the scale value to insert into the indicating instrument, it is necessary to multiply the number found 15 (as calculated in the above example) by the value of the scale on the table corresponding to C.T. 300/5A, which is 30KW (KVar) Therefore 15 x 30KW (KVar) = 450KW (KVar) TABLE OF INTERCHANGEABLE SCALES CURRENT TRANSFORMER 5/5 A 10/5 A 15/5 A 20/5 A 25/5 A 30/5 A 40/5 A 50/5 A 60/5 A 80/5 A 100/5 A 150/5 A 200/5 A 250/5 A 300/5 A 400/5 A 500/5 A 600/5 A 800/5 A 1000/5 A 1500/5 A 2000/5 A 2500/5 A THREE-PHASE WATTMETER AND VARMETER 100V 230V 400V SINGLE-PHASE WATTMETER AND VARMETER 100V 230V 400V 500 W (VAR) 1000 W (VAR) 1500 W (VAR) 2000 W (VAR) 2500 W (VAR) 3000 W (VAR) 4000 W (VAR) 5000 W (VAR) 6000 W (VAR) 8000 W (VAR) 10 KW (KVAR) 15 KW (KVAR) 20 KW (KVAR) 25 KW (KVAR) 30 KW (KVAR) 40 KW (KVAR) 50 KW (KVAR) 60 KW (KVAR) 80 KW (KVAR) 100 KW (KVAR) 150 KW (KVAR) 200 KW (KVAR) 250 KW (KVAR) 1000 W (VAR) 2000 W (VAR) 3000 W (VAR) 4000 W (VAR) 5000 W (VAR) 6000 W (VAR) 8000 W (VAR) 10 KW (KVAR) 12 KW (KVAR) 16 KW (KVAR) 20 KW (KVAR) 30 KW (KVAR) 40 KW (KVAR) 50 KW (KVAR) 60 KW (KVAR) 80 KW (KVAR) 100 KW (KVAR) 120 KW (KVAR) 160 KW (KVAR) 200 KW (KVAR) 300 KW (KVAR) 400 KW (KVAR) 500 KW (KVAR) 2000 W (VAR) 4000 W (VAR) 6000 W (VAR) 8000 W (VAR) 10 KW (KVAR) 12 KW (KVAR) 16 KW (KVAR) 20 KW (KVAR) 24 KW (KVAR) 32 KW (KVAR) 40 KW (KVAR) 60 KW (KVAR) 80 KW (KVAR) 100 KW (KVAR) 120 KW (KVAR) 160 KW (KVAR) 200 KW (KVAR) 240 KW (KVAR) 320 KW (KVAR) 400 KW (KVAR) 600 KW (KVAR) 800 KW (KVAR) 1000 KW (KVAR) 1000 W (VAR) 2000 W (VAR) 3000 W (VAR) 4000 W (VAR) 5000 W (VAR) 6000 W (VAR) 8000 W (VAR) 10 KW (KVAR) 12 KW (KVAR) 16 KW (KVAR) 20 KW (KVAR) 30 KW (KVAR) 40 KW (KVAR) 50 KW (KVAR) 60 KW (KVAR) 80 KW (KVAR) 100 KW (KVAR) 120 KW (KVAR) 160 KW (KVAR) 200 KW (KVAR) 300 KW (KVAR) 400 KW (KVAR) 500 KW (KVAR) WITH INCORPORATED ELECTRONIC 2000 W (VAR) 4000 W (VAR) 6000 W (VAR) 8000 W (VAR) 10 KW (KVAR) 12 KW (KVAR) 16 KW (KVAR) 20 KW (KVAR) 24 KW (KVAR) 32 KW (KVAR) 40 KW (KVAR) 60 KW (KVAR) 80 KW (KVAR) 100 KW (KVAR) 120 KW (KVAR) 160 KW (KVAR) 200 KW (KVAR) 240 KW (KVAR) 320 KW (KVAR) 400 KW (KVAR) 600 KW (KVAR) 800 KW (KVAR) 1000 KW (KVAR) 4000 W (VAR) 8000 W (VAR) 12 KW (KVAR) 16 KW (KVAR) 20 KW (KVAR) 24 KW (KVAR) 32 KW (KVAR) 40 KW (KVAR) 48 KW (KVAR) 64 KW (KVAR) 80 KW (KVAR) 120 KW (KVAR) 160 KW (KVAR) 200 KW (KVAR) 240 KW (KVAR) 320 KW (KVAR) 400 KW (KVAR) 480 KW (KVAR) 640 KW (KVAR) 800 KW (KVAR) 1200 KW (KVAR) 1600 KW (KVAR) 2000 KW (KVAR) SWITCHBOARD VERSION The scales are linear with values expressed in: - wattmeters: watt (W), kilowatt (KW), megawatt (MW) - varmeters: var (Var), kilovar (Kvar), megavar (Mvar) Indications necessary when ordering: phase-phase or phase-neutral voltage, current, end scale value, primary and secondary value of CT or VT (if present) Accuracy Class 1,5 Dimensions 96x96 mm Wattmeters - 90˚ Scale plate Active Energy Single phase 3 phase, balanced load, w/out neutral, 3 wire 3 phase, unbalanced load, without neutral, 3 wire (ARON) 3 phase, balanced load, with neutral, 4 wire 3 phase, unbalanced load, with neutral, 4 wire ERW96/1 283,25 Reactive Energy Single phase 3 phase, balanced load, w/out neutral, 3 wire 3 phase, unbalanced load, without neutral, 3 wire (ARON) 3 phase, balanced load, with neutral, 4 wire 3 phase, unbalanced load, with neutral, 4 wire ERV96/1 283,25 ERW96/2 ERW96/3 ERW96/4 ERW96/5 ERWL96/1 350,20 346,10 ERWL96/2 ERWL96/3 ERWL96/4 350,20 391,40 346,10 355,35 391,40 ERV96/2 ERWL96/5 355,35 Varmeters - 90˚ Scale plate 12 Wattmeters - 240˚ Scale plate ERV96/3 ERV96/4 ERV96/5 346,10 406,85 Varmeters - 240˚ Scale plate ERVL96/1 350,20 ERVL96/2 ERVL96/3 ERVL96/4 ERVL96/5 355,35 350,20 391,40 346,10 355,35 391,40 406,85 01 listino GB analogici prezzi ITA:listino ITA 15/11/10 16:11 Pagina 13 WITH EXTERNAL ELECTRONIC 90° SCALE PLATE Dimensions 48x48, 72x72, 96x96, 144x144 mm for reading instruments; 6 DIN modules for transducers These instruments are made up of an direct current indicator (230 standard power supply, other on request) and by an external accessory The scales are linear with values expressed in: - wattmeters: watt (W), kilowatt (KW), megawatt (MW) - varmeters: var (Var), kilovar (Kvar), megavar (Mvar) Indications necessary when ordering: phase-phase or phase-neutral voltage, current, end scale value, primary and secondary value of CT or VT (if present) Reading instruments ERCC96 have 2 thresholds alarm Class 1,5 WATTMETER Active Energy Single phase 3 phase, balanced load, w/out neutral, 3 wire 3 phase, unbalanced load, without neutral, 3 wire (ARON) 3 phase, balanced load, with neutral, 4 wire 3 phase, unbalanced load, with neutral, 4 wire DC Reading instruments, input 1 mA 1CORPA10 1CORPA20 1CORPA30 1CORPA40 1CORPA50 355,35 355,35 453,20 355,35 520,15 VARMETER Reactive Energy Single phase 3 phase, balanced load, w/out neutral, 3 wire 3 phase, unbalanced load, without neutral, 3 wire (ARON) 3 phase, balanced load, with neutral, 4 wire 3 phase, unbalanced load, with neutral, 4 wire DC Reading instruments, input 1 mA 1CORPR10 1CORPR20 1CORPR30 1CORPR40 1CORPR50 365,65 365,65 453,20 365,65 530,45 ERCM ERC48 ERC72 ERC96 ERC144 ERCC96 50,45 48,10 48,10 48,10 63,35 360,50 ERCM ERC48 ERC72 ERC96 ERC144 ERCC96 50,45 48,10 48,10 48,10 63,35 360,50 WITH EXTERNAL ELECTRONIC 240° SCALE PLATE Dimensions 48x48, 72x72, 96x96, 144x144 mm for reading instruments; 6 DIN modules for transducers These instruments are made up of an direct current indicator (230 standard power supply, other on request) and by an external accessory The scales are linear with values expressed in: - wattmeters: watt (W), kilowatt (KW), megawatt (MW) - varmeters: var (Var), kilovar (Kvar), megavar (Mvar) Indications necessary when ordering: phase-phase or phase-neutral voltage, current, end scale value, primary and secondary value of CT or VT (if present) Class 1,5 WATTMETER Active Energy Single phase 3 phase, balanced load, w/out neutral, 3 wire 3 phase, unbalanced load, without neutral, 3 wire (ARON) 3 phase, balanced load, with neutral, 4 wire 3 phase, unbalanced load, with neutral, 4 wire DC Reading instruments, input 1 mA 1CORPA10 1CORPA20 1CORPA30 1CORPA40 1CORPA50 355,35 355,35 453,20 355,35 520,15 VARMETER Reactive Energy Single phase 3 phase, balanced load, w/out neutral, 3 wire 3 phase, unbalanced load, without neutral, 3 wire (ARON) 3 phase, balanced load, with neutral, 4 wire 3 phase, unbalanced load, with neutral, 4 wire DC Reading instruments, input 1 mA 1CORPR10 1CORPR20 1CORPR30 1CORPR40 1CORPR50 365,65 365,65 453,20 365,65 530,45 ERCL48 ERCL72 ERCL96 122,55 103,00 103,00 ERCL48 ERCL72 ERCL96 122,55 103,00 103,00 SINGLE PHASE INSULATION INDICATORS SINGLE PHASE MODULAR AND SWITCHBOARD VERSION These instruments are used to measure continuously, with power applied, the insulation value respect to the earth of single phase lines with insulated neutral; or the insulation respect to the mass of the positive and negative of direct current lines. The indicators ERCC96MI are provided with a separate accessory transducer (1RAMI) on which the power circuit is included. Auxiliary power supply 100VCA Auxiliary power supply 400VCA Auxiliary power supply 220VCC 100 380 220C ERCMMI (ERCM + 1RAMI) 154,50 154,50 ERC48MI (ERC48 + 1RAMI) 154,50 154,50 ERC72MI (ERC72 + 1RAMI) 154,50 154,50 ERC96MI (ERC96 + 1RAMI) 154,50 154,50 ERC144MI ERCC96MI (ERC144 + 1RAMI) (ERCC96 + 1RAMI) 169,95 360,50 169,95 360,50 412,00 13 01 listino GB analogici prezzi ITA:listino ITA 15/11/10 16:11 Pagina 14 ACCESSORIES FRONT PROTECTION SYSTEMS IP65 FRONT PROTECTION The hole made in the panel may need to be increased by up 2 mm depending on the accuracy of the original cut out, in respect to the corresponding dimensions indicated on catalogue ARP432 17,20 instrument 48x96 instrument 72x72 instrument 96x96 ARP433 ARP434 20,65 24,00 AKIP6548 4,25 instrument 48x48 instrument 72x72 instrument 96x96 A48G 0,55 AKIP6596 4,85 5,45 RUBBER GASKETS instrument 48x48 instrument 72x72 instrument 96x96 AKIP6572 REAR TERMINAL COVERS A72G A96G 0,60 0,65 A48C 2,15 instrument 48x48 instrument 72x72 instrument 96x96 and 144x144 A72C A96C 2,25 2,35 FIXING SYSTEMS ASF1 4,75 with internal spring for instruments 48x48, 72x72 and 96x96 screws (standard) for instruments 48x48, 72x72 and 96x96 screws with flat terminal to avoid holes on plastic panels for instruments 48x48, 72x72 and 96x96 screws for synotic switchboard for instruments 48x48, 72x72 and 96x96 with internal spring for instruments 36x72 and 48x96 ASF2 ASF21 ASF22 88ASACDGT 0,70 0,85 1,20 4,75 BLANK PLATES ARP48 7,75 instrument 48x48 instrument 72x72 instrument 96x96 instrument 48x96 ARP72 ARP96 ARP4896 7,75 9,75 9,75 GLASSES For 90˚ instruments A4890V 2,50 instrument 48x48 instrument 72x72 instrument 96x96 A48240V 4,95 A72240V A4890VA 4,95 A7290VA A9690VA 6,60 A48240VA 9,95 5,40 A72240VA APG7290 APG9690 11,60 APG48240 8,50 9,20 APG72240 9,95 MAXIMUM DEMAND AMMETER KIT The kit is composed by: white frame, glass, red pointer and zero adjusting for black pointer AKIR48 9,45 APG96240 9,20 9,95 RED POINTER KIT A96240VA 10,75 5,80 APG4890 8,50 A96240V 5,80 3,30 instrument 48x48 - policarbonate instrument 72x72 - policarbonate instrument 96x96 - policarbonate 14 A9690V 2,90 instrument 48x48 - antireflex instrument 72x72 - antireflex instrument 96x96 - antireflex instrument 48x48 instrument 72x72 instrument 96x96 A7290V For 240˚ instruments The kit is composed by: white frame, glass, red pointer and zero adjusting AKIR72 Standard Combined AKIR96 10,05 10,65 instrument 72x72 instrument 96x96 AKB72 2,95 AKB96 3,55 AKBC72 4,75 AKBC96 5,35 01 listino GB analogici prezzi ITA:listino ITA 15/11/10 16:11 Pagina 15 ADAPTERS Adapter 72x72 for instruments 48x48 Adapter 96x96 for instruments 72x72 Adapter 96x96 for instruments 48x48 Adapter 48x96 for instruments 36x72 Adapter 72x72 for 2 module instruments Adapter 72x72 for 3 module instruments Adapter 96x96 for 2 module instruments Adapter 96x96 for 3 module instruments Adapter 96x96 for 4 module instruments ARAD7248 8,65 ARAD9672 ARAD9648 ARAD482 ARAD722 ARAD723 ARAD962 ARAD963 ARAD964 10,80 10,80 10,80 14,20 14,20 15,35 15,35 15,35 TRANSFORMING FROM A 4 MODULES METER TO A 96X96 METER + ARAD964 = 4 DIN modules 96x96 mm instruments SWITCHES MODULAR AND SWITCHBOARD VERSION The mechanical life is 1.5 million operations with running temperature ranging from -20°C to + 60°C Nominal Current 12A The contacts are electrosoldered in Silver/Nickel The voltage referring to the insulation is 690V The degrees of protection on the clamps is in IP20 Contact angle 45° AMMETER SELECTOR SWITCHES Single pole three current transformers, 3 elements Single pole three current transformers, 3 elements in case dimensions VOLTMETER SELECTOR SWITCHES Phase-Neutral connection, 2 elements 0-L1N-L2N-L3N Phase-Phase connection, 2 elements 0-L1L2-L2L3-L3L1 Phase-Phase and Phase-Neutral connection, 3 elements L3N-L2N-L1N / 0 / L1L2-L2L3-L3L1 Phase-Phase and Phase-Neutral connection, 3 elements in case L3N-L2N-L1N / 0 / L1L2-L2L3-L3L1 Phase-Phase two different lines connection, 4 elements L3L1-L2L3-L1L2 / 0 / L1L2-L2L3-L3L1 dimensions ON-OFF SWITCHES single-pole two-pole three-pole four-pole dimensions 0-1 0-1 0-1 0-1 1RIN1201D 15,95 1RCO1215D 22,20 1RCO1216D 3DIN 1RCO1218D 22,20 1RCO1222DS 37,10 3DIN 2RCO1222QP 24,85 52x52 1RCO1218DS 2RCO1215QP 2RCO1216QP 2RCO1217QP 2RCO1218QP 18,15 18,15 27,30 23,70 36,05 3DIN 1RIN1203D 3DIN 1RIN1204D 26,25 3DIN 1RCO1222D 26,80 3DIN 22,15 REVERSING SWITCHES three-pole dimensions 1RIN1202D 0-L1-L2-L3 0-L1-L2-L3 3DIN 30,40 3DIN 1RINV1208D 24,70 1-0-1 3DIN 3DIN 3DIN 52x52 CHANGE-OVER SWITCHES single-pole two-pole three-pole dimensions ACCESSORIES Flexible transparent protective casing 1-0-2 1-0-2 1-0-2 52x52 31,20 52x52 52x52 1RCO1205D 1RCO1206D 1RCO1207D 18,05 22,20 25,75 3DIN 3DIN 3DIN AR109DF 1,85 15 01 listino GB analogici prezzi ITA:listino ITA 15/11/10 16:11 Pagina 16 HOUR RUN METERS MODULAR VERSION Frequency: 50 or 60 Hz in AC to be specified when ordering Display AC 99999,99 h 2 x 99999,99 h DC 99999,9 h Dimensions: 1 or 2 DIN modules Single 1RH1 61,80 Multi Power supply from 12V AC/DC to 250V AC/DC ± 10% Power supply 24 V AC ± 10% Power supply 110 V AC ± 10% Power supply 230 V AC ± 10% Power supply 400 V AC ± 10% Power supply 12-36 V DC Power supply 2 x 230 V AC ± 10% 1RH24 1RH110 1RH230 1RH400 1RH36C Double 1RHD230 28,85 28,85 28,85 30,90 47,40 47,40 SWITCHBOARD VERSION Frequency: 50 or 60 Hz in AC to be specified when ordering Display AC 99999,99 h; DC 999999,9 h Protection IP65 (4RK47R and 4RK46Q) Nominal voltage in AC and DC 10...60V 80...150V 150...250V Nominal voltage in AC: 24V, 48V, 60V, 110V, 230V, 380V Nominal voltage in DC: 10...50VCC Nominal voltage in DC: 12...36VCC Dimensions in mm 4RK47R 20,00 25,00 30,00 4RK30 4RK301236C 4RK46Q 20,00 25,00 30,00 20,70 4RK46 4RK461050C 4RH72 16,50 4RH721050C 21,30 ø58 24x36 55x55 55x55 AM72E 1,90 Accessories Adapter Jig for type 4RK46 Adapter Jig for type 4RK30 Dimensions mm 72x72 WITH CERTIFICATIONS FOR FISCAL USE 46,35 55x55 4RH961050C 23,70 36,05 30,90 24x36 4RH96 72x72 51,50 72x72 96x96 96x96 AMRK2448 AMRK4848 AMRK5555 AMRK7272 AMRK058 AMRK072 1,35 24x48 1,55 48x48 1,70 55x55 1,90 72x72 1,70 Ø58 1,90 Ø72 MODULAR AND SWITCHBOARD VERSION Different auxiliary poer supply on request Frequency: 50 or 60 Hz in AC to be specified when ordering Multi Power supply from 12V AC/DC to 250V AC/DC ± 10% Power supply 230V Power supply 230V and 100V to be specified when ordering one input current 5A Power supply 230V and 100V to be specified when ordering three input currents 5A Power supply 230V and 100V to be specified when ordering one input current 1A Power supply 230V and 100V to be specified when ordering three input currents 1A Full certification service Dimensions 1RH1 61,80 1RH230 1RH3 28,85 149,35 1RHA315 1RHA335 1RHA311 1RHA331 4RK46 RMCC 16,50 195,70 221,45 195,70 221,45 123,60 1DIN 2DIN 3DIN 3DIN 3DIN 3DIN 3DIN 55x55 IMPULSE COUNTERS MODULAR AND SWITCHBOARD VERSION Display 999999 (6 entires, height 4 mm) Power supply (to specify when ordering): Power supply (to specify when ordering): Power supply 16 6 - 12 - 24 - 48 - 110 - 230 VCA 6 - 12 - 24 - 48 - 60 - 110 VCC 220 VCC 5RSI62.0 20,60 17,00 19,05 5RSI62.2 20,60 17,00 19,05 5RSI62.4 21,65 17,50 19,55 02 listino GB digitali prezzi ITA:listino ITA 15/11/10 16:12 Pagina 17 DIGITAL INSTRUMENTS TABLE SWITCHBOARD VERSION 4 DIGIT MODULAR VERSION 3 DIGIT STANDARD TRUE RMS TRUE RMS TRUE RMS max depth 82 mm max depth 53 mm max depth 82 mm 2 DIN modules A.C. and D.C. current A.C. and D.C. current A.C. current D.C. current Alarm thresholds A.C. current NO D.C. current 1 threshold NO 1 threshold 2 thresholds (1 for 48x48) VOLTMETERS 96X96 72X72 end scale 48X96 800V 36X72 Option RS485 Option 4/20mA With alarms end scale 500V ...420 2RID96V...-600 2RID72V...-600 2RID48V...-600 2RID36V...-600 ...-600RS ...420 ...S600 2ERID96V... 2ERID72V... 2ERID488V... 2ERID48V... 2ERID36V... 2ERCD96V... 2ERCD72V... 2ERCD488V... 2ERCD48V... 2ERCD36V... 2RID96SV... 2RID96SV...S 2RID96SV... 2RID96SV...S 2RID72SV... 2RID72SV... 2RID48SV... 2RID48SV...S 2RID48SV... 2RID48SV...S 2RID36SV... 2RID36SV... 1RIMD2V... 96X96 72X72 48X48 end scale 48X96 500V or 36X72 100V 2DIN Option RS485 Option 4/20mA input 5A 96X96 72X72 48X48 48X96 36X72 2DIN 2RD96V...G100 2RD72V...100 2RD48V...G100 2RD36V...100 1RMD2V... ...420 2ERID96A... 2ERID72A... 2ERID488A... 2ERID48A... 2ERID36A... 2RID96SA... 2RID96SA...S 2RID72SA... 2RID48SA... 2RID48SA...S 2RID36SA... 1RIMD2A... ...C100 AMMETERS 96X96 72X72 input 60mV 48X48 48X96 36X72 2ERCD96A... 2ERCD72A... 2ERCD488A... 2ERCD48A... 2ERCD36A... FREQUENCYMETERS 1RSDI ...C100 2RCD96SA... 2RCD96SA...S 2RCD72SA... 2RCD48SA... 2RCD48SA...S 2RCD36SA... 96X96 72X72 48X48 input 5A (1A) 48X96 or 60mV with “Imax 36X72 demand” 2DIN Option RS485 Option 4/20mA DIGIT height 2RD96V...GS100 2RD72V...-S100 2RD488V...-S100 2RD48V...GS100 2RD36V...-S100 ...100RS Option split current CT 96X96 72X72 48X48 48X96 36X72 2DIN Option RS485 Option 4/20mA 1 MIN + 1 MAX ...S800 96X96 72X72 48X96 end scale 600V 36X72 Option RS485 Option 4/20mA With alarms 96X96 72X72 48X48 48X96 36X72 2DIN NO 2RCD96V...-800 2RCD72V...-800 2RCD48V...-800 2RCD36V...-800 ...-800RS 2RD96A...G 2RD72A... 2RD48A...G 2RD36A... 2RD96A...GS 2RD72A...-S 2RD488A...-S 2RD48A...GS 2RD36A...-S 1RMD2A... ...RS ...420 2ERID96SF... 2ERID72SF.... 2ERID488SF.... 2ERID48SF.... 2ERID36SF.... 2RD96F...G 2RD72F... 2RD48F...G 2RD36F... 2RD96F...GS 2RD72F...-S 2RD488F...-S 2RD48F...GS 2RD36F...-S 1RIMD2F... ...RS ...420 14 mm (8 mm 48x48) 14 mm 8 mm (48x48); 14 mm (36x72 e 72x72), 20 mm (96x96 e 48x96) 10 mm 17 02 listino GB digitali prezzi ITA:listino ITA 15/11/10 16:12 Pagina 18 DIGITAL INSTRUMENTS TABLE SWITCHBOARD VERSION 4 DIGIT STANDARD TRUE RMS TRUE RMS TRUE RMS max depth 82 mm max depth 53 mm max depth 82 mm 2 DIN modules A.C. and D.C. current A.C. and D.C. current A.C. current D.C. current Alarm thresholds PROCESS INSTRUMENTS supplied with several measuring units set MODULAR VERSION 3 DIGIT A.C. current NO D.C. current 1 threshold NO 1 threshold 2 thresholds (1 for 48x48) 96X96 72X72 VOLTMETERS 48X48 end scale 48X96 10V or 1V 36X72 2DIN Option RS485 Option 4/20mA 2RD96V...G101 2RD72V...101 2RD488V...101 2RD48V...G101 2RD36V...101 96X96 72X72 48X48 48X96 36X72 2DIN Option RS485 Option 4/20mA 2RD96T...G-... 2RD72T...--... NO 1 MIN + 1 MAX 2RD96V...GS101 2RD72V...-S101 2RD488V...-S101 2RD48V...GS101 2RD36V...-S101 1RMD2V100(101) ..101RS ...420 MILLI AMMETERS input to define when ordering between: 1-5-10-204/20 mA 2RD96T...GS... 2RD72T...-S... 2RD488T...-S... 2RD48T...GS... 2RD36T...-S... 2RD48T...G-... 2RD36T...--... 1RMD2T... ..RS ...420 SINGLE-PHASE DOUBLE V+A 96X96 72X72 2DIN SINGLE-PHASE DOUBLE V+F 2DIN 1RIMD2VF 250... THREE-PHASE DOUBLE V+A 2DIN 1RIMD23AV THREE-PHASE TRIPLE V+A+F 96X96 72X72 2RD96AV..G 2RD72AV.. 2RD96AV...GS 2RD72AV...-S 1RIMDA2V... 2RD963AV.. 2RD723AV.. ...C100 Option split current CT DIGIT height 14 mm (8 mm 48x48) 8 mm (48x48); 14 mm (36x72 e 72x72), 20 mm (96x96 e 48x96) 14 mm 10 mm DIGITAL SWITCHBOARD INSTRUMENTS - STANDARD CODES TABLES 2 E R I D 7 2 V - P E R I D 4 8 8 A power supply dimensions digital instruments identification 2 6 measuring unit ammeters, voltmeters and frequencymeters 48x48 power supply measuring unit dimensions digital instruments identification ammeters, voltmeters and frequencymeters 36x72, 48x96, 72x72 and 96x96 2 3 0 I = AC C = DC 36 = 36x72 72 = 72x72 48 = 48x96 96 = 96x96 A = ammeter AC = 5A; DC = 60mV V = voltmeter AC and DC = 500V F = frequencymeter (40-80Hz) 230 = 230VAC -P6 = 48...230VAC and 48...250VDC Spaces reserved to the codes when VT .../100V and/or TV..../110V is connected. Example: 2010=20kV/100V; 2011=20kV/110V; 1510=15kV/100V; 1511=15kV/110V 18 Space reserved to ammeters only: = secondary 5A 1 = secondary 1A 02 listino GB digitali prezzi ITA:listino ITA 15/11/10 16:12 Pagina 19 VOLTMETERS FOR A.C. CURRENT SWITCHBOARD VERSION 1 display, 4 digit red colour, digit height 14 mm (8 mm for models 48x48 and 36x72) Frequency: 45÷65 Hz Class 0,5% ±2 digit referred to the end scale value Standard end scale value 500V Input 100V and 110V insertion by VT: Supply 230V=19,00 Euro; Supply -P6=24,00 Euro Depth: 82 mm Standard auxiliary power supply 230VAC Sole auxiliary power supply 48...230VAC and 48...250VDC Dimensions mm 230 -P6 2ERID96V... 70,05 103,00 96x96 2ERID72V... 70,05 103,00 72x72 FOR D.C. CURRENT 2ERID488V... 70,05 103,00 48x48 2ERID48V... 70,05 103,00 48x96 2ERID36V... 70,05 103,00 36x72 SWITCHBOARD VERSION 1 display, 4 digit red colour, digit height 14 mm (8 mm for models 48x48 and 36x72) Class 0,5% ±2 digit referred to the end scale value Standard end scale value 500V Depth: 82 mm Standard auxiliary power supply 230VAC Sole auxiliary power supply 48...230VAC and 48...250VDC Dimensions mm 230 -P6 2ERCD96V... 2ERCD72V... 70,05 70,05 103,00 103,00 96x96 72x72 2ERCD488V... 70,05 103,00 48x48 2ERCD48V... 2ERCD36V... 70,05 70,05 103,00 103,00 48x96 36x72 AMMETERS FOR A.C. CURRENT SWITCHBOARD VERSION 1 display, 4 digit red colour, digit height 14 mm (8 mm for models 48x48 and 36x72) Frequency: 45÷65 Hz Class 0,5% ±2 digit referred to the end scale value Selectable end scale value between 1 and 9000A, according to DIN standards Input 5A - it is necessary to connect the CT .../5A correspondent to the end scale value setted Depth: 82 mm Standard auxiliary power supply 230VAC Sole auxiliary power supply 48...230VAC and 48...250VDC Dimensions mm 230 -P6 2ERID96A... 70,05 103,00 96x96 2ERID72A... 2ERID488A... 2ERID48A... 70,05 70,05 70,05 103,00 103,00 103,00 72x72 48x48 48x96 FOR D.C. CURRENT 2ERID36A... 70,05 103,00 36x72 SWITCHBOARD VERSION 1 display, 4 digit red colour, digit height 14 mm (8 mm for models 48x48 and 36x72) Class 0,5% ±2 digit referred to the end scale value Selectable end scale value between 1 and 9000A, according to DIN standards Input 60mV - it is necessary to connect the SHUNT .../60mV correspondent to the end scale value setted Depth: 82 mm Standard auxiliary power supply 230VAC Sole auxiliary power supply 48...230VAC and 48...250VDC Dimensions mm 230 -P6 2ERCD96A... 2ERCD72A... 2ERCD488A... 2ERCD48A... 2ERCD36A... 70,05 70,05 70,05 70,05 70,05 103,00 103,00 103,00 103,00 103,00 96x96 72x72 48x48 48x96 36x72 FREQUENCYMETERS SWITCHBOARD VERSION 1 display, 4 digit red colour, digit height 14 mm (8 mm for models 48x48 and 36x72) Frequency: 45÷65 Hz Class 0,5% ±2 digit referred to the end scale value End scale value between 0 to 80Hz max 500V Depth: 82 mm Standard auxiliary power supply 230VAC Sole auxiliary power supply 48...230VAC and 48...250VDC Dimensions mm 230 -P6 2ERID96F 133,90 144,20 96x96 2ERID72F 133,90 144,20 72x72 2ERID488F 133,90 144,20 48x48 2ERID48F 133,90 144,20 48x96 2ERID36F 133,90 144,20 36x72 19 02 listino GB digitali prezzi ITA:listino ITA 15/11/10 16:12 Pagina 20 SWITCHBOARD INSTRUMENTS - TRMS - REDUCED DEPTH AMMETERS 5A + option “Split current CT” FOR A.C. CURRENT SWITCHBOARD VERSION 1 display, 4 digit red colour, maximum reading: 9000 Class: 0,5 Input 5A - it is necessary to connect the CT .../5A correspondent to the end scale value setted These codes (....-C100) are supplied together with a mini split core transformer in class 1 able to measure up to 100A and powers up to 23kW single phase. This solution permits a quick installation in already existing panels or nets as that it is not necessary to disconnect the power cable as needed by the classic current transformers. This CT accepts a cable diameter 12mm maximum and its position on the cable doesn’t influence the readings. Standard auxiliary power supply 230VAC Auxiliary power supply 24VCA Auxiliary power supply 110VCA Option “Split current CT” suffix ....C100 Dimensions mm 230 -24 110 Extra price Frequency: 50/60 Hz Selectable end scale value between 1 and 9999A, steps 5A each Depth: 53 mm 2RID36SA 2RID48SA 2RID72SA 2RID96SA 2RID36SA...C100 2RID48SA...C100 2RID72SA...C100 2RID96SA...C100 82,40 82,40 82,40 82,40 87,55 87,55 87,55 87,55 87,55 87,55 87,55 87,55 16,00 16,00 16,00 16,00 36x72 48x96 72x72 96x96 FOR A.C. CURRENT WITH THRESHOLD ALARM 1 display, 4 digit red colour, maximum reading: 9000 Frequency: 50/60 Hz Class: 0,5 Selectable end scale value between 1 and 9999A, steps 5A each Input 5A - it is necessary to connect the CT .../5A correspondent to the end scale value setted Depth: 53 mm One threshold alarm N.O. - 0,5A/1000V Standard auxiliary power supply 230VAC Auxiliary power supply 24VCA Auxiliary power supply 110VCA Option “Split current CT” suffix ....C100 Dimensions mm 230 -24 110 Extra price 2RID48SA...S 2RID96SA...S 2RID48SA...S-C100 2RID96SA...S-C100 103,00 103,00 108,15 108,15 108,15 108,15 16,00 16,00 48x96 96x96 AMMETERS 60mV FOR D.C. CURRENT SWITCHBOARD VERSION 1 display, 4 digit red colour, maximum reading: 9000 Class: 0,5 Selectable end scale value between 1 and 9999A, steps 5A each Input 60mV - it is necessary to connect the SHUNT .../60mV correspondent to the end scale value setted Depth: 53 mm Standard auxiliary power supply 230VAC Auxiliary power supply 24VCA Auxiliary power supply 110VCA Dimensions mm 230 -24 110 2RCD36SA 82,40 87,55 87,55 36x72 2RCD48SA 82,40 87,55 87,55 48x96 2RCD72SA 82,40 87,55 87,55 72x72 2RCD96SA 82,40 87,55 87,55 96x96 FOR D.C. CURRENT WITH THRESHOLD ALARM 1 display, 4 digit red colour, maximum reading: 9000 Class: 0,5 Selectable end scale value between 1 and 9999A, steps 5A each Input 60mV - it is necessary to connect the SHUNT .../60mV correspondent to the end scale value setted Depth: 53 mm One threshold alarm N.O. - 0,5A/1000V Standard auxiliary power supply 230VAC Auxiliary power supply 24VCA Auxiliary power supply 110VCA Dimensions mm 230 -24 110 2RCD48SA...S 2RCD96SA...S 103,00 103,00 108,15 108,15 108,15 108,15 48x96 96x96 VOLTMETERS FOR A.C. AND D.C. CURRENT SWITCHBOARD VERSION 1 display, 4 digit red colour, maximum reading: 500,0 Frequency: 50/60 Hz Class: 0,5 End scale value 500V - In D.C. current the instrument shows positive measure only Depth: 53 mm Standard auxiliary power supply 230VAC Auxiliary power supply 24VCA Auxiliary power supply 110VCA Dimensions mm 20 230 -24 110 2RID36SV... 82,40 87,55 87,55 36x72 2RID48SV... 82,40 87,55 87,55 48x96 2RID72SV... 82,40 87,55 87,55 72x72 2RID96SV... 82,40 87,55 87,55 96x96 02 listino GB digitali prezzi ITA:listino ITA 15/11/10 16:12 Pagina 21 FOR A.C. AND D.C. CURRENT WITH THRESHOLD ALARM 1 display, 4 digit red colour, maximum reading: 500,0 Frequency: 50/60 Hz Class: 0,5 End scale value 500V - In D.C. current the instrument shows positive measure only Depth: 53 mm One threshold alarm N.O. - 0,5A/1000V Standard auxiliary power supply 230VAC Auxiliary power supply 24VCA Auxiliary power supply 110VCA Dimensions mm 230 -24 110 2RID48SV...S 2RID96SV...S 103,00 103,00 108,15 108,15 108,15 108,15 48x96 96x96 SWITCHBOARD INSTRUMENTS - TRUE RMS - DEPTH 82mm ammeters, voltmeters and frequencymeters 36x72, 48x96, 72x72 and 96x96 ammeters, voltmeters and frequencymeters 48x48 voltmeters voltmeters 2 4 0 1 0 4 2 0 2 R D 4 8 8 A 2 3 0 - S range power supply measuring unit dimensions digital instruments identification Options - range - alarm threshold - digit dimensions V alarm threshold 2 ammeters and frequencymeters digit dimensions 2 R D 7 power supply measuring unit dimensions digital instruments identification ammeters and frequencymeters 0 0 1 -24 = 24VAC 110 = 110VAC 230 = 230VAC -P1 = 22...36VAC and 19...70VDC -P2 = 44...130VAC and 70...240VDC 36 = 36x72 72 = 72x72 48 = 48x96 96 = 96x96 A = ammeter (5A-60mV) V = voltmeter F = frequencymeter (45-100Hz) T = settable only for models - = 14 mm 48x96 and 96x96 G = 20 mm 2 alarm thresholds - = NO S = YES 001 = 1mA 010 = 10mA 420 = 4/20mA 420 = Option 4/20mA -RS = Option RS485 LBR = Option LED brightness reduction - = 8 mm 005 = 5mA 020 = 20mA 1 alarm threshold S = YES 100 = 500V or 100V 101 = 10V or 1V ADHESIVE LABELS Where indicated this adhesive labels set is supplied free of charge. It contains several measuring units to apply on the proper front area under necessity VOLTMETERS 500V or 100V + option RS485 + option 4/20mA + option LBR FOR A.C. AND D.C. CURRENT kA A V kV kVA kW l/sec l/min m/min m/sec m/min g °C BAR °F Giri/min RPM % bar mA Personal unit % W Hz kvar l/h m/h kg RPM RPM dB SWITCHBOARD VERSION A.C. and D.C. range 500V (lower ranges can be selected using the “Dot” function in “Programming page”) or 100V (used as end scale value or secondary input from VT). Primaries values between 0500 to 9999V with 5V steps can be selected by the front button The connection of these 2 inputs cannot be effected contemporary. If 500V input is used, it is non possible to connect the 100V terminals also and viceversa. As option, it is possible to have this range with an output RS485 MODBUS RTU (insulation 3kV). Option not available for model 36x72 mm with DC auxiliary supply. Option 4/20mA (passive 2 wires aux supply 20...30VDC). This analogue output cannot be present together with option RS485. Option LED Brightness Reduction permits to reduce the brightness of led when requested. Expecially indicated for naval and rail-way use 1 display, 4 digit red colour Frequency: 0÷100 Hz Class 0,5% ±2 digit referred to the end scale value Depth: 82 mm Standard auxiliary power supply 230V Auxiliary power supply 24V Auxiliary power supply 110V Sole auxiliary power supply 22...36VAC and 19...70VDC Sole auxiliary power supply 44...130VAC and 70...240VDC Option RS485 MODBUS RTU (not available for 36x72 DC aux supply) Option 4/20mA Option LBR Digit height mm Dimensions mm 230 -24 110 -P1 -P2 Extra price Extra price Extra price 2RD96V...G100 2RD96V...G100-RS 2RD96V...G100420 2RD96V...G100LBR 123,60 128,75 128,75 182,00 182,00 60,00 50,00 30,00 20 96x96 2RD72V...100 2RD72V...100-RS 2RD72V...100420 2RD72V...100LBR 113,30 118,45 118,45 172,00 172,00 60,00 50,00 30,00 14 72x72 2RD48V...G100 2RD48V...G100-RS 2RD48V...G100420 2RD48V...G100LBR 123,60 128,75 128,75 182,00 182,00 60,00 50,00 30,00 20 48x96 2RD36V...100 2RD36V...100-RS 2RD36V...100420 2RD36V...100LBR 113,30 118,45 118,45 172,00 172,00 60,00 50,00 30,00 14 36x72 21 02 listino GB digitali prezzi ITA:listino ITA 15/11/10 16:12 Pagina 22 FOR A.C. AND D.C. CURRENT WITH THRESHOLD ALARM SWITCHBOARD VERSION A.C. and D.C. range 500V (lower ranges can be selected using the “Dot” function in “Programming page”) or 100V (used as end scale value or secondary input from VT). Primaries values between 0500 to 9999V with 5V steps can be selected by the front button The connection of these 2 inputs cannot be effected contemporary. If 500V input is used, it is non possible to connect the 100V terminals also and viceversa. 1 display, 4 digit red colour Frequency: 0÷100 Hz Class 0,5% ±2 digit referred to the end scale value One threshold alarm N.O. for model 48x48, two thresholds for others models Relay data: 8A, 250V Depth: 82 mm Standard auxiliary power supply 230V Auxiliary power supply 24V Auxiliary power supply 110V Sole auxiliary power supply 22...36VAC and 19...70VDC Sole auxiliary power supply 44...130VAC and 70...240VDC Digit height mm Dimensions mm 230 -24 110 -P1 -P2 2RD96V...GS100 2RD72V...-S100 2RD488V...-S100 2RD48V...GS100 2RD36V...-S100 154,50 144,20 144,20 154,50 144,20 159,65 149,35 149,35 159,65 149,35 159,65 149,35 149,35 159,65 149,35 213,00 202,00 202,00 213,00 202,00 213,00 202,00 202,00 213,00 202,00 20 14 8 20 14 96x96 72x72 48x48 48x96 36x72 VOLTMETERS 10V or 1V + option RS485 + option 4/20mA + option LBR FOR A.C. AND D.C. CURRENT SWITCHBOARD VERSION A.C. and D.C. range 10V or 1V. Primaries values between 0500 to 9999V with 5V steps can be selected by the front button The connection of these 2 inputs cannot be effected contemporary. If 500V input is used, it is non possible to connect the 100V terminals also and viceversa. As option, it is possible to have this range with an output RS485 MODBUS RTU (insulation 3kV). Option not available for model 36x72 mm with DC auxiliary supply. Option 4/20mA (passive 2 wires aux supply 20...30VDC). This analogue output cannot be present together with option RS485. Option LED Brightness Reduction permits to reduce the brightness of led when requested. Expecially indicated for naval and rail-way use Adhesive labels set supplied containing several measuring units to apply on the proper front area under necessity 1 display, 4 digit red colour Frequency: 0÷100 Hz 2RD96V...G101 Class 0,5% ±2 digit referred to the end scale value 2RD96V...G101-RS 2RD96V...G101420 Depth: 82 mm Standard auxiliary power supply 230V Auxiliary power supply 24V Auxiliary power supply 110V Sole auxiliary power supply 22...36VAC and 19...70VDC Sole auxiliary power supply 44...130VAC and 70...240VDC Option RS485 MODBUS RTU (not available for 36x72 DC aux supply) Option 4/20mA Option LBR Digit height mm Dimensions mm 230 -24 110 -P1 -P2 Extra price Extra price Extra price 2RD96V...G101LBR 123,60 128,75 128,75 182,00 182,00 60,00 50,00 30,00 20 96x96 FOR A.C. AND D.C. CURRENT WITH THRESHOLD ALARM 2RD72V.....101 2RD72V...101-RS 2RD72V...101420 2RD72V...101LBR 113,30 118,45 118,45 172,00 172,00 60,00 50,00 30,00 14 72x72 2RD48V...G101 2RD48V...G101-RS 2RD48V...G101420 2RD48V...G101LBR 123,60 128,75 128,75 182,00 182,00 60,00 50,00 30,00 20 48x96 2RD36V...101 2RD36V...101-RS 2RD36V...101420 2RD36V...101LBR 113,30 118,45 118,45 172,00 172,00 60,00 50,00 30,00 14 36x72 SWITCHBOARD VERSION A.C. and D.C. range 10V or 1V. Primaries values between 0500 to 9999V with 5V steps can be selected by the front button The connection of these 2 inputs cannot be effected contemporary. If 10V input is used, it is non possible to connect the 1V terminals also and viceversa. Adhesive labels set supplied containing several measuring units to apply on the proper front area under necessity 1 display, 4 digit red colour Frequency: 0÷100 Hz Class 0,5% ±2 digit referred to the end scale value One threshold alarm N.O. for model 48x48, two thresholds for others models Relay data: 8A, 250V Depth: 82 mm Standard auxiliary power supply 230V Auxiliary power supply 24V Auxiliary power supply 110V Sole auxiliary power supply 22...36VAC and 19...70VDC Sole auxiliary power supply 44...130VAC and 70...240VDC Digit height mm Dimensions mm 22 230 -24 110 -P1 -P2 2RD96V...GS101 2RD72V...-S101 2RD488V...-S101 2RD48V...GS101 2RD36V...-S101 154,50 144,20 144,20 154,50 144,20 159,65 149,35 149,35 159,65 149,35 159,65 149,35 149,35 159,65 149,35 213,00 202,00 202,00 213,00 202,00 213,00 202,00 202,00 213,00 202,00 20 14 8 20 14 96x96 72x72 48x48 48x96 36x72 02 listino GB digitali prezzi ITA:listino ITA 15/11/10 16:12 Pagina 23 VOLTMETERS 600V AC + option RS485 + option 4/20mA + option LBR FOR A.C. CURRENT SWITCHBOARD VERSION A.C. range 600V As option, it is possible to have this range with an output RS485 MODBUS RTU (insulation 3kV). Option not available for model 36x72 mm with DC auxiliary supply. Option 4/20mA (passive 2 wires aux supply 20...30VDC). This analogue output cannot be present together with option RS485. Option LED Brightness Reduction permits to reduce the brightness of led when requested. Expecially indicated for naval and rail-way use 1 display, 4 digit red colour 2RD96V...G600 Frequency: 0÷100 Hz 2RD96V...G600-RS Class 0,5% ±2 digit referred to the end scale value 2RD96V...G600420 Depth: 82 mm Standard auxiliary power supply 230V 230 Auxiliary power supply 24V -24 Auxiliary power supply 110V 110 Sole auxiliary power supply 22...36VAC and 19...70VDC -P1 Sole auxiliary power supply 44...130VAC and 70...240VDC -P2 Option RS485 MODBUS RTU (not available for 36x72 and DC aux supply) Extra price Option 4/20mA Extra price Option LBR Extra price Digit height mm Dimensions mm 2RD96V...G600LBR 123,60 128,75 128,75 182,00 182,00 60,00 50,00 30,00 20 96x96 2RD72V.....600 2RD72V...600-RS 2RD72V...600420 2RD72V...600LBR 113,30 118,45 118,45 172,00 172,00 60,00 50,00 30,00 14 72x72 FOR A.C. CURRENT WITH THRESHOLD ALARM 2RD48V...G600 2RD48V...G600-RS 2RD48V...G600420 2RD48V...G600LBR 123,60 128,75 128,75 182,00 182,00 60,00 50,00 30,00 20 48x96 2RD36V...600 2RD36V...600-RS 2RD36V...600420 2RD36V...600LBR 113,30 118,45 118,45 172,00 172,00 60,00 50,00 30,00 14 36x72 SWITCHBOARD VERSION A.C. range 600V. 1 display, 4 digit red colour Frequency: 0÷100 Hz Class 0,5% ±2 digit referred to the end scale value One threshold alarm N.O. for model 48x48, two thresholds for others models Relay data: 8A, 250V Depth: 82 mm Standard auxiliary power supply 230V Auxiliary power supply 24V Auxiliary power supply 110V Sole auxiliary power supply 22...36VAC and 19...70VDC Sole auxiliary power supply 44...130VAC and 70...240VDC Digit height mm Dimensions mm 230 -24 110 -P1 -P2 2RD96V...GS600 2RD72V...-S600 2RD48V...GS600 2RD36V...-S600 154,50 144,20 154,50 144,20 159,65 149,35 159,65 149,35 159,65 149,35 159,65 149,35 213,00 202,00 213,00 202,00 213,00 202,00 213,00 202,00 20 14 20 14 96x96 72x72 48x96 36x72 VOLTMETERS 800V DC + option RS485 + option 4/20mA + option LBR FOR D.C. CURRENT SWITCHBOARD VERSION D.C. range 800V As option, it is possible to have this range with an output RS485 MODBUS RTU (insulation 3kV). Option not available for model 36x72 mm with DC auxiliary supply. Option 4/20mA (passive 2 wires aux supply 20...30VDC). This analogue output cannot be present together with option RS485. Option LED Brightness Reduction permits to reduce the brightness of led when requested. Expecially indicated for naval and rail-way use 2RCD96V...G800 2RCD72V.....800 2RCD48V...G800 2RCD36V...800 1 display, 4 digit red colour Depth: 82 mm 2RCD96V...G800-RS 2RCD72V...800-RS 2RCD48V...G800-RS 2RCD36V...800-RS Class 0,5% ±2 digit referred to the end scale value 2RCD96V...G800420 2RCD72V...800420 2RCD48V...G800420 2RCD36V...800420 Standard auxiliary power supply 230V Auxiliary power supply 24V Auxiliary power supply 110V Sole auxiliary power supply 22...36VAC and 19...70VDC Sole auxiliary power supply 44...130VAC and 70...240VDC Option RS485 MODBUS RTU (not available for 36x72 DC aux supply) Option 4/20mA Option LBR Digit height mm Dimensions mm 230 -24 110 -P1 -P2 Extra price Extra price Extra price 2RCD96V...G800LBR 123,60 128,75 128,75 182,00 182,00 60,00 50,00 30,00 20 96x96 FOR D.C. CURRENT WITH THRESHOLD ALARM 2RCD72V...800LBR 113,30 118,45 118,45 172,00 172,00 60,00 50,00 30,00 14 72x72 2RCD48V...G800LBR 123,60 128,75 128,75 182,00 182,00 60,00 50,00 30,00 20 48x96 2RCD36V...800LBR 113,30 118,45 118,45 172,00 172,00 60,00 50,00 30,00 14 36x72 SWITCHBOARD VERSION D.C. range 800V. 1 display, 4 digit red colour Class 0,5% ±2 digit referred to the end scale value One threshold alarm N.O. for model 48x48, two thresholds for others models Relay data: 8A, 250V Depth: 82 mm Standard auxiliary power supply 230V Auxiliary power supply 24V Auxiliary power supply 110V Sole auxiliary power supply 22...36VAC and 19...70VDC Sole auxiliary power supply 44...130VAC and 70...240VDC Digit height mm Dimensions mm 230 -24 110 -P1 -P2 2RCD96V...GS800 2RCD72V...-S800 2RCD48V...GS800 2RCD36V...-S800 154,50 144,20 154,50 144,20 159,65 149,35 159,65 149,35 159,65 149,35 159,65 149,35 213,00 202,00 213,00 202,00 213,00 202,00 213,00 202,00 20 14 20 14 96x96 72x72 48x96 36x72 23 02 listino GB digitali prezzi ITA:listino ITA 15/11/10 16:12 Pagina 24 AMMETERS 5A (1A) or 60mV with “I max demand” + option RS485 + option 4/20mA + option LBR FOR A.C. AND D.C. CURRENT SWITCHBOARD VERSION A.C. and D.C. range between 5,00 to 9999 - Input 5A - it is necessary to connect the CT .../5A correspondent to the end scale value setted. Input between 0500 to 9999A with 5A steps, selectable by the front button. Lower ranges then 500A can be selected using the “Dot” function in “Programming page”. - Input 1A - This range is obtained multiplying the primary value of CT to use for the constant K= 5 (example: 1000/1A -> K=5000). Practically, if the primary current is 1000A, you have to connect the CT 1000/1A but on the programming page (FcS) you have to select 5000. The maximum CT in this case must be 2000/1A and the precision class is 1%. - Input 60mV - it is necessary to connect the SHUNT .../60mV correspondent to the end scale value setted Frequency: 0÷100 Hz 1 display, 4 digit red colour Depth: 82 mm Class 0,5% ±2 digit referred to the end scale value These ammeters have the possibility to effect two measures (integrated on the time): - The medium current (AC+DC) in a certain time by a “fluent window” (Current Demand) selectable from 5 to 30 minutes (resolution 1 minute) - The maximum value reached by the medium current (Max Current Demand) during all the working period of the instrument (settable parameter) THE CONNECTION OF THESE 2 INPUTS CANNOT BE EFFECTED CONTEMPORARY. If 5A input is used, it is non possible to connect the 60mV terminals also and viceversa. Once the adhesive label is removed, Revalco is not responsible to damages caused by a wrong connections. As option, it is possible to have this range with an output RS485 MODBUS RTU (insulation 3kV). Option not available for model 36x72 mm with DC auxiliary supply. Option 4/20mA (passive 2 wires aux supply 20...30VDC). This analogue output cannot be present together with option RS485. Option LED Brightness Reduction permits to reduce the brightness of led when requested. Expecially indicated for naval and rail-way use Standard auxiliary power supply 230V Auxiliary power supply 24V Auxiliary power supply 110V Sole auxiliary power supply 22...36VAC and 19...70VDC Sole auxiliary power supply 44...130VAC and 70...240VDC Option RS485 MODBUS RTU (not available for 36x72 DC aux supply) Option 4/20mA Option LBR Digit height mm Dimensions mm 230 -24 110 -P1 -P2 Extra price Extra price Extra price 2RD96A...G 2RD96A...G-RS 2RD96A...G-420 2RD96A...G-LBR 133,90 139,05 139,05 192,00 192,00 60,00 50,00 30,00 20 96x96 2RD72A... 2RD72A...-RS 2RD72A...-420 2RD72A...-LBR 123,60 128,75 128,75 182,00 182,00 60,00 50,00 30,00 14 72x72 FOR A.C. AND D.C. CURRENT WITH THRESHOLD ALARM 2RD48A...G 2RD48A...G-RS 2RD48A...G-420 2RD48A...G-LBR 133,90 139,05 139,05 192,00 192,00 60,00 50,00 30,00 20 48x96 2RD36A... 2RD36A...-RS 2RD36A...-420 2RD36A...-LBR 123,60 128,75 128,75 182,00 182,00 60,00 50,00 30,00 14 36x72 SWITCHBOARD VERSION A.C. and D.C. range between 5,00 to 9999 - Input 5A - it is necessary to connect the CT .../5A correspondent to the end scale value setted. Input between 0500 to 9999A with 5A steps, selectable by the front button. Lower ranges then 500A can be selected using the “Dot” function in “Programming page”. - Input 1A - This range is obtained multiplying the primary value of CT to use for the constant K= 5 (example: 1000/1A -> K=5000). Practically, if the primary current is 1000A, you have to connect the CT 1000/1A but on the programming page (FcS) you have to select 5000. The maximum CT in this case must be 2000/1A and the precision class is 1%. - Input 60mV - it is necessary to connect the SHUNT .../60mV correspondent to the end scale value setted These ammeters have the possibility to effect two measures (integrated on the time): - The medium current (AC+DC) in a certain time by a “fluent window” (Current Demand) selectable from 5 to 30 minutes (resolution 1 minute) - The maximum value reached by the medium current (Max Current Demand) during all the working period of the instrument (settable parameter) THE CONNECTION OF THESE 2 INPUTS CANNOT BE EFFECTED CONTEMPORARY. If 5A input is used, it is non possible to connect the 60mV terminals also and viceversa. Once the adhesive label is removed, Revalco is not responsible to damages caused by a wrong connections. 1 display, 4 digit red colour Frequency: 0÷100 Hz Class 0,5% ±2 digit referred to the end scale value One threshold alarm N.O. for model 48x48, two thresholds for others models Relay data: 8A, 250V Depth: 82 mm Standard auxiliary power supply 230V Auxiliary power supply 24V Auxiliary power supply 110V Sole auxiliary power supply 22...36VAC and 19...70VDC Sole auxiliary power supply 44...130VAC and 70...240VDC Digit height mm Dimensions mm 24 230 -24 110 -P1 -P2 2RD96A...GS 164,80 169,95 169,95 223,00 223,00 20 96x96 2RD72A...-S 154,50 159,65 159,65 213,00 213,00 14 72x72 2RD488A...-S 154,50 159,65 159,65 213,00 213,00 8 48x48 2RD48A...GS 164,80 169,95 169,95 223,00 223,00 20 48x96 2RD36A...-S 154,50 159,65 159,65 213,00 213,00 14 36x72 02 listino GB digitali prezzi ITA:listino ITA 15/11/10 16:12 Pagina 25 MILLIAMMETERS 1mA / 5mA / 10mA / 20mA / 4-20mA + option RS485 + option 4/20mA + option LBR FOR A.C. AND D.C. CURRENT SWITCHBOARD VERSION Range: 0-20mA = 2RD..T230---020 4-20mA = 2RD..T230---420 0-10mA = 2RD..T230---010 0-5mA = 2RD..T230---005 0-1mA = 2RD..T230---001 This instruments has one input only which must be specified during the order As option, it is possible to have this range with an output RS485 MODBUS RTU (insulation 3kV). Option not available for model 36x72 mm with DC auxiliary supply. Option 4/20mA (passive 2 wires aux supply 20...30VDC). This analogue output cannot be present together with option RS485. Option LED Brightness Reduction permits to reduce the brightness of led when requested. Expecially indicated for naval and rail-way use Adhesive labels set supplied containing several measuring units to apply on the proper 2RD96T...G-... 2RD72T...--... 2RD48T...G-... 2RD36T...--... front area under necessity 2RD96T...G-...RS 2RD72T...--...RS 2RD48T...G-...RS 2RD36T...--...RS 1 display, 4 digit red colour Frequency: 0÷100 Hz 2RD96T...G-...420 2RD72T...--...420 2RD48T...G-...420 2RD36T...--...420 Class 0,5% ±2 digit referred to the end scale value Depth: 82 mm Standard auxiliary power supply 230V 230 Auxiliary power supply 24V -24 Auxiliary power supply 110V 110 Sole auxiliary power supply 22...36VAC and 19...70VDC -P1 Sole auxiliary power supply 44...130VAC and 70...240VDC -P2 Option RS485 MODBUS RTU (not available for 36x72 DC aux supply) Option 4/20mA Option LBR Digit height mm Dimensions mm 020 / 420 / 010 / 005 / 001 020 / 420 / 010 / 005 / 001 020 / 420 / 010 / 005 / 001 020 / 420 / 010 / 005 / 001 020 / 420 / 010 / 005 / 001 Extra price Extra price Extra price 2RD96T...G-...LBR 2RD72T...--...LBR 2RD48T...G-...LBR 2RD36T...--...LBR 149,35 139,05 149,35 139,05 154,50 144,20 154,50 144,20 154,50 144,20 154,50 144,20 208,00 198,00 208,00 198,00 208,00 198,00 208,00 198,00 60,00 60,00 60,00 60,00 50,00 50,00 50,00 50,00 30,00 30,00 30,00 30,00 20 14 20 14 96x96 72x72 48x96 36x72 FOR A.C. AND D.C. CURRENT WITH THRESHOLD ALARM SWITCHBOARD VERSION Range: 0-20mA = 2RD..T230—020 4-20mA = 2RD..T230—420 0-10mA = 2RD..T230—010 This instruments has one input only which must be specified during the order Adhesive labels set supplied containing several measuring units to apply on the proper front area under necessity 1 display, 4 digit red colour Frequency: 0÷100 Hz Class 0,5% ±2 digit referred to the end scale value One threshold alarm N.O. for model 48x48, two thresholds for others models Relay data: 8A, 250V Depth: 82 mm Standard auxiliary power supply 230V 230 Auxiliary power supply 24V -24 Auxiliary power supply 110V 110 Sole auxiliary power supply 22...36VAC and 19...70VDC -P1 Sole auxiliary power supply 44...130VAC and 70...240VDC -P2 Digit height mm Dimensions mm 020 / 420 / 010 / 005 / 001 020 / 420 / 010 / 005 / 001 020 / 420 / 010 / 005 / 001 020 / 420 / 010 / 005 / 001 020 / 420 / 010 / 005 / 001 2RD96T...GS... 180,25 185,40 185,40 239,00 239,00 20 96x96 0-5mA = 2RD..T230—005 2RD72T...-S... 169,95 180,25 180,25 229,00 229,00 14 72x72 2RD488T...-S... 169,95 180,25 180,25 229,00 229,00 8 48x48 0-1mA = 2RD..T230—001 2RD48T...GS... 180,25 185,40 185,40 239,00 239,00 20 48x96 2RD36T...-S... 169,95 180,25 180,25 229,00 229,00 14 36x72 FREQUENCYMETERS + option RS485 + option 4/20mA + option LBR SWITCHBOARD VERSION As option, it is possible to have this range with an output RS485 MODBUS RTU (insulation 3kV). Option not available for model 36x72 mm with DC auxiliary supply. Option 4/20mA (passive 2 wires aux supply 20...30VDC). This analogue output cannot be present together with option RS485. Option LED Brightness Reduction permits to reduce the brightness of led when requested. Expecially indicated for naval and rail-way use Adhesive labels set supplied containing several measuring units to apply on the proper front area under necessity 2RD96F...G 2RD72F... 2RD48F...G 2RD36F... 1 display, 4 digit red colour Depth: 82 mm 2RD96F...G-RS 2RD72F...-RS 2RD48F...G-RS 2RD36F...-RS Frequency: 10÷100 Hz max 500V (min 70V) and max 100V fromt VT (min 15V) 2RD96F...G420 2RD72F...420 2RD48F...G420 2RD36F...420 Class 0,005% ±1 digit referred to the end scale value between 45÷65Hz 2RD96F...GLBR 2RD72F...LBR 2RD48F...GLBR 2RD36F...LBR Standard auxiliary power supply 230V Auxiliary power supply 24V Auxiliary power supply 110V Sole auxiliary power supply 22...36VAC and 19...70VDC Sole auxiliary power supply 44...130VAC and 70...240VDC Option RS485 MODBUS RTU (not available for 36x72 DC aux supply) Option 4/20mA Option LBR Digit height mm Dimensions mm 154,50 159,65 159,65 213,00 213,00 60,00 50,00 30,00 20 96x96 230 -24 110 -P1 -P2 Extra price Extra price Extra price WITH THRESHOLD ALARM 154,50 159,65 159,65 213,00 213,00 60,00 50,00 30,00 20 48x96 154,50 159,65 159,65 213,00 213,00 60,00 50,00 30,00 14 36x72 SWITCHBOARD VERSION Adhesive labels set supplied containing several measuring units to apply on the proper front area under necessity 1 display, 4 digit red colour Depth: 82 mm Frequency: 10÷100 Hz max 500V (min 70V) and max 100V fromt VT (min 15V) Class 0,005% ±1 digit referred to the end scale value between 45÷65Hz One threshold alarm N.O. for model 48x48, two thresholds for others models Relay data: 8A, 250V (0,1A - 230V for model 48x48) Standard auxiliary power supply 230V Auxiliary power supply 24V Auxiliary power supply 110V Sole auxiliary power supply 22...36VAC and 19...70VDC Sole auxiliary power supply 44...130VAC and 70...240VDC Digit height mm Dimensions mm 154,50 159,65 159,65 213,00 213,00 60,00 50,00 30,00 14 72x72 230 -24 110 -P1 -P2 2RD96F...GS 185,40 190,55 190,55 244,00 244,00 20 96x96 2RD72F...-S 185,40 190,55 190,55 244,00 244,00 14 72x72 2RD488F...-S 185,40 190,55 190,55 244,00 244,00 8 48x48 2RD48F...GS 185,40 190,55 190,55 244,00 244,00 20 48x96 2RD36F...-S 185,40 190,55 190,55 244,00 244,00 14 36x72 25 02 listino GB digitali prezzi ITA:listino ITA 15/11/10 16:12 Pagina 26 DOUBLE SINGLE PHASE INSTRUMENTS with “I max demand” + option RS485 + option 4/20mA + option LBR VOLTMETERS + AMMETERS FOR A.C. AND D.C. CURRENT SWITCHBOARD VERSION Voltmeter range A.C. and D.C. 500V or 100V Ammeter range A.C. and D.C. between 5,00 to 9999 - Input 5A - it is necessary to connect the CT .../5A correspondent to the end scale value setted. Input between 0500 to 9999A with 5A steps, selectable by the front button. Lower ranges then 500A can be selected using the “Dot” function in “Programming page”. - Input 60mV - it is necessary to connect the SHUNT .../60mV correspondent to the end scale value setted These ammeters have the possibility to effect two measures (integrated on the time): - The medium current (AC+DC) in a certain time by a “fluent window” (Current Demand) selectable from 5 to 30 minutes (resolution 1 minute) - The maximum value reached by the medium current (Max Current Demand) during all the working period of the instrument (settable parameter) The connection of these 2 inputs cannot be effected contemporary. If 5A input is used, it is non possible to connect the 60mV terminals also and viceversa. If 500V input is used, it is non possible to connect the 100V terminals also and viceversa. As option, it is possible to have this range with an output RS485 MODBUS RTU (insulation 3kV). Option 4/20mA (passive 2 wires aux supply 20...30VDC). This analogue output cannot be present together with option RS485. Option LED Brightness Reduction permits to reduce the brightness of led when requested. Expecially indicated for naval and rail-way use 2 displayes, 4 digit red colour. Digit height 14 mm (20 mm for model 96x96) Class 0,5% ±2 digit referred to the end scale value Frequency: 0÷100 Hz Depth: 82 mm Standard auxiliary power supply 2 x 230V Auxiliary power supply 2 x 24V Auxiliary power supply 2 x 110V Sole auxiliary power supply 2 x 22...36VAC and 19...70VDC Sole auxiliary power supply 2 x 44...130VAC and 70...240VDC Option RS485 MODBUS RTU Option 4/20mA Option LBR Dimensions mm 230 -24 110 -P1 -P2 Extra price Extra price Extra price 2RD96AV...G 2RD96AV...G-RS 2RD96AV...G420 2RD96AV...GLBR 164,80 169,95 169,95 282,00 282,00 120,00 100,00 60,00 96x96 VOLTMETERS+AMMETERS FOR A.C. AND D.C. CURRENT WITH THRESHOLD ALARM 2RD72AV... 2RD72AV...-RS 2RD72AV...420 2RD72AV...LBR 144,20 149,35 149,35 261,00 261,00 120,00 100,00 60,00 72x72 SWITCHBOARD VERSION Voltmeter range A.C. and D.C. 500V or 100V Ammeter range A.C. and D.C. between 5,00 to 9999 - Input 5A - it is necessary to connect the CT .../5A correspondent to the end scale value setted. Input between 0500 to 9999A with 5A steps, selectable by the front button. Lower ranges then 500A can be selected using the “Dot” function in “Programming page”. - Input 60mV - it is necessary to connect the SHUNT .../60mV correspondent to the end scale value setted These ammeters have the possibility to effect two measures (integrated on the time): - The medium current (AC+DC) in a certain time by a “fluent window” (Current Demand) selectable from 5 to 30 minutes (resolution 1 minute) - The maximum value reached by the medium current (Max Current Demand) during all the working period of the instrument (settable parameter) The connection of these 2 inputs cannot be effected contemporary. If 5A input is used, it is non possible to connect the 60mV terminals also and viceversa. If 500V input is used, it is non possible to connect the 100V terminals also and viceversa. 2 displayes, 4 digit red colour. Digit height 14 mm (20 mm for model 96x96) Frequency: 0÷100 Hz Class 0,5% ±2 digit referred to the end scale value Two thresholds alarm N.O. on Voltmeter and two thresholds alarm N.O. on Ammeter Relay data: 8A, 250V Depth: 82 mm Standard auxiliary power supply 2 x 230V Auxiliary power supply 2 x 24V Auxiliary power supply 2 x 110V Sole auxiliary power supply 2 x 22...36VAC and 19...70VDC Sole auxiliary power supply 2 x 44...130VAC and 70...240VDC Dimensions mm 230 -24 110 -P1 -P2 2RD96AV...GS 206,00 211,15 211,15 323,00 323,00 96x96 2RD72AV...-S 154,50 159,65 159,65 272,00 272,00 72x72 TRIPLE THREE PHASE INSTRUMENTS + option “Split current CT” VOLTMETERS+AMMETERS+FREQUENCYMETERS FOR A.C. AND D.C. CURRENT Ammeter range between 5 to 999A with 5A steps, selectable by the front button Input 5A - it is necessary to connect the CT .../5A correspondent to the end scale value setted Voltmeter range (phase-neutral) 290V max - (phase-phase) 500V max Frequencymeter range 45/80 Hz 3 displayes, 3 digit red colour. Digit height 7 mm Class 0,5% ±2 digit referred to the end scale value Depth: 82 mm These codes (....-C100) are supplied together with a mini split core transformer in class 1 L3 L2 able to measure up to 100A and powers up to 23kW single phase. This solution permits a quick installation in already existing panels or nets as that it is not necessary to disconnect the power cable as needed by the classic current transformers. This CT accepts a cable diameter 12mm maximum and its position on the cable doesn’t influence the readings. Standard auxiliary power supply 3 x 230V Auxiliary power supply 3 x 24V Auxiliary power supply 3 x 110V Sole auxiliary power supply 3 x 22...36VAC and 19...70VDC Sole auxiliary power supply 3 x 44...130VAC and 70...240VDC Option “Split current CT” suffix ....C100 Dimensions mm 26 SWITCHBOARD VERSION Frequency: 0÷100 Hz L1 230 -24 110 -P1 -P2 Extra price 2RD723AV... 2RD723AV...C100 118,45 118,45 118,45 294,00 294,00 16,00 72x72 2RD963AV... 2RD963AV...C100 122,45 122,45 122,45 298,00 298,00 16,00 96x96 02 listino GB digitali prezzi ITA:listino ITA 15/11/10 16:12 Pagina 27 BARGRAPH INDICATORS LED SWITCHBOARD VERSION LED test: when powered, these devices make a self test lighting-on each LED every 200ms The measure of the values is in true RMS also in presence of distorsions up to the 20th harmonic wave. These instruments are provvided by a relay with commutation function when (after minimum 10 sec from the powering) the following permanent conditions (for minimum 5 sec) are present: 190V > voltage < 260V; 48Hz > frequency < 52Hz; or 58Hz > frequency < 62Hz The condition “contact in alarm” is immediate; condition “light-off device” means that the contact is in alarm position as well as voltage and/or frequency been out of the mentioned range. Self power supply 140...260V Voltage input 290V max Current input 5A 2RI72HAVH...A Current, Voltage and Frequency Voltage and Frequency Current, Voltage, Frequency and hourmeter Dimensions mm 2RI36AVHZ...APT 66,95 2RI36VHZPT 61,80 77,25 72x72 36x72 36x72 LED INDICATORS VOLTMETER SWITCHBOARD VERSION Economic Voltmeter constituted by 5 red LEDS suitable for use on generating sets or any net subjected to vibrations. This device is available in horizontal (2RI33V230) and vertical (2RI33V230T) version able to read voltage at 230V, or in horizontal (2RI33V400) and vertical (2RI33V400T) version able to read voltage at 400V, (but referred to 230VAC auxiliary power supply) Instrument measures phase-neutral voltage only (230V). The same instrument can shows the measure of 400V (model 2RI33V400 and 2RI33V400T), but in any case the connection must be linked to 230V (230V x 3= 400V ) Auxiliary power supply self supplied Range 40...300VAC Voltmeter circuit Direct insertion max 300V Thermic overload 400V for 5 seconds Frequency range 45...65Hz 2RI33V230 Patented instruments VA/2006/A/33 2RI33V400 13,40 Horizontal version Vertical version Dimensions mm 2RI33V230T 2RI33V400T 13,40 30,6x47 47x30,6 VOLTMETER + FREQUENCYMETER SWITCHBOARD VERSION These instruments make it possible to adjust the voltage and frequency in small electronic units. As it is possible to replace the voltmeter and frequency meter there is a considerable saving from a economical point of view as well as space on the electrical switchboard. Instruments are calibrated at 230V, 50Hz - If the electronic unit delivers 230V at 50Hz the green Led lights up - If there is a drop in the voltage of the above-mentioned data, the yellow Led lights up (while the green Led remains light) - If on the other hand there is an increase in the above-mentioned data, the red Led lights up (while the green Led remains light) - In order to restore the normal values it is sufficient to accellerate or slow down the speed of the electronic unit motor until the yellow or red Leds go out. In a three phase system, the phase-neutral connection (230V) is comparable to a phase-phase connection (400V) Burden / Class: 0,5VA / 1% Display by 2 or 3 groups of leds Selfpowered auxiliary supply: 230V +/-10% Standard instruments are calibrated at 230V, 50Hz Input 230V phase-neutral connection (reading between 210 to 250 V): Frequency input 50Hz (reading between 48 to 52 Hz) Input 230V phase-neutral connection (reading between 380 to 420 V): Frequency input 50Hz (reading between 48 to 52 Hz) Dimensions mm DIGITAL MODULAR INSTRUMENTS - 2RI36VH400 2RI36VH230 49,00 49,00 36x72 36x72 TRUE RMS VOLTMETERS SOLE INPUT 500V MODULAR VERSION Frequency: 0÷100 Hz Class 0,5% ±2 digit referred to the end scale value 1 display, 3 digit red colour. Digit height 10 mm Out scale indication: frontal red led lights on End scale value: 500VAC standard Standard auxiliary power supply 230V Auxiliary power supply 24V Auxiliary power supply 110V Sole auxiliary power supply 22...36VAC and 19...70VDC Sole auxiliary power supply 44...130VAC and 70...240VDC Dimensions mm 230 -24 110 -P1 -P2 1RIMD2V... 66,95 82,40 82,40 125,50 125,50 2DIN 27 02 listino GB digitali prezzi ITA:listino ITA 15/11/10 16:12 Pagina 28 DOUBLE INPUT 500V or 100V MODULAR VERSION Frequency: 0÷100 Hz Class 0,5% ±2 digit referred to the end scale value 1 display, 3 digit red colour. Digit height 10 mm Out scale indication: frontal red led lights on End scale value: 500V AC/DC or 100V AC/DC standard Instruments usefull for direct input 500V or by selectable VT (400/100V - 500/100V) The connection of these 2 inputs cannot be effected contemporary. If 500V input is used, it is non possible to connect the 100V terminals also and viceversa. Standard auxiliary power supply 230V Auxiliary power supply 24V Auxiliary power supply 110V Sole auxiliary power supply 22...36VAC and 19...70VDC Sole auxiliary power supply 44...130VAC and 70...240VDC Dimensions mm 230 -24 110 -P1 -P2 1RMD2V... 66,95 82,40 82,40 125,50 125,50 2DIN VOLTMETERS 10V or 1V FOR A.C. AND D.C. CURRENT MODULAR VERSION A.C. and D.C. range 10V (1RMD2V100...) or 1V (1RMD2V101...) 1 display, 3 digit red colour. Digit height 10 mm Frequency: 0÷100 Hz Class 0,5% ±2 digit referred to the end scale value Standard auxiliary power supply 230V Auxiliary power supply 24V Auxiliary power supply 110V Sole auxiliary power supply 22...36VAC and 19...70VDC Sole auxiliary power supply 44...130VAC and 70...240VDC Dimensions mm 230 -24 110 -P1 -P2 1RMD2V100... 80,35 98,90 98,90 139,00 139,00 2DIN 1RMD2V101... 80,35 98,90 98,90 139,00 139,00 2DIN AMMETERS SOLE INPUT 5A MODULAR VERSION Frequency: 0÷100 Hz Class 0,5% ±2 digit referred to the end scale value 1 display, 3 digit red colour. Digit height 10 mm Ammeter range between 5 to 999A with 5A steps, selectable by the front button Input 5A - it is necessary to connect the CT .../5A correspondent to the end scale value setted Standard auxiliary power supply 230V Auxiliary power supply 24V Auxiliary power supply 110V Sole auxiliary power supply 22...36VAC and 19...70VDC Sole auxiliary power supply 44...130VAC and 70...240VDC Dimensions mm DOUBLE INPUT 5A or 60mV 230 -24 110 -P1 -P2 1RIMD2A... 66,95 82,40 82,40 125,50 125,50 2DIN MODULAR VERSION Frequency: 0÷100 Hz Class 0,5% ±2 digit referred to the end scale value 1 display, 3 digit red colour. Digit height 10 mm End scale value A.C. and D.C.: between 5 to 999A with 5A steps, selectable by the front button - Input 5A - it is necessary to connect the CT .../5A correspondent to the end scale value setted - Input 1A - This range is obtained multiplying the primary value of CT to use for the constant K= 5 (example: 100/1A -> K=500). Practically, if the primary current is 100A, you have to connect the CT 100/1A but on the programming page (FcS) you have to select 500. The maximum CT in this case must be 200/1A and the precision class is 1%. - Input 60mV - it is necessary to connect the SHUNT .../60mV correspondent to the end scale value setted The connection of these 2 inputs cannot be effected contemporary. If 5A input is used, it is non possible to connect the 60mV terminals also and viceversa. 1RMD2A... Standard auxiliary power supply 230V Auxiliary power supply 24V Auxiliary power supply 110V Sole auxiliary power supply 22...36VAC and 19...70VDC Sole auxiliary power supply 44...130VAC and 70...240VDC Dimensions mm DOUBLE THRESHOLD (MIN/MAX) 230 -24 110 -P1 -P2 66,95 82,40 82,40 125,50 125,50 2DIN MODULAR VERSION 2 displayes, 3 digit red colour. Digit height 8 mm End scale value: between 0,1 to 999A selectable by the front button - Input 5A - it is necessary to connect the CT .../5A correspondent to the end scale value setted CT setting range between 5 to 999A with 5A steps, selectable by the front button Maximum current 6A Relay: 1 contact N.O., 250V/10A resistive load Function: - True RMS current measure by CT .../5A - 2 settable current thresholds with only one output by N.O. relay - thresholds indication - Settable optical pre-alarm Standard auxiliary power supply 230V +/- 10%, 50/60 Hz Dimensions 28 1RSDI 92,70 2DIN 02 listino GB digitali prezzi ITA:listino ITA 15/11/10 16:12 Pagina 29 MILLIAMMETERS 1mA / 5mA / 10mA / 20mA / 4-20mA FOR A.C. AND D.C. CURRENT MODULAR VERSION Range: 0-20mA = 1RMD2T---020 4-20mA = 1RMD2T---420 0-10mA = 1RMD2T---010 This instruments has one input only which must be specified during the order 1 display, 3 digit red colour. Digit height 10 mm Frequency: 0÷100 Hz Class 0,5% ±2 digit referred to the end scale value 0-5mA = 1RMD2T---005 Standard auxiliary power supply 230V Auxiliary power supply 24V Auxiliary power supply 110V Sole auxiliary power supply 22...36VAC and 19...70VDC Sole auxiliary power supply 44...130VAC and 70...240VDC Dimensions mm 230 -24 110 -P1 -P2 0-1mA = 1RMD2T---001 020 / 420 / 010 / 005 / 001 020 / 420 / 010 / 005 / 001 020 / 420 / 010 / 005 / 001 020 / 420 / 010 / 005 / 001 020 / 420 / 010 / 005 / 001 1RMD2T... 80,35 98,90 98,90 139,00 139,00 2DIN FREQUENCYMETERS MODULAR VERSION 1 display, 3 digit red colour. Digit height 10 mm Frequency: 10÷100 Hz max 500V (min 70V) Class 0,005% ±1 digit referred to the end scale value between 45÷65Hz Standard auxiliary power supply 230V Auxiliary power supply 24V Auxiliary power supply 110V Sole auxiliary power supply 22...36VAC and 19...70VDC Sole auxiliary power supply 44...130VAC and 70...240VDC Dimensions mm 230 -24 110 -P1 -P2 1RIMD2F... 92,70 103,00 103,00 151,00 151,00 2DIN DOUBLE SINGLE PHASE INSTRUMENTS VOLTMETERS + AMMETERS MODULAR VERSION 2 displayes, 3 digit red colour. Digit height 10 mm Frequency: 10÷100 Hz max 500V (min 70V) Class 0,5% ±2 digit referred to the end scale value Voltmeter end scale value: 500V standard Ammeter end scale value: between 5 to 999A with 5A steps, selectable by the front button. Input 5A - it is necessary to connect the CT .../5A correspondent to the end scale value setted. Standard auxiliary power supply 230V Auxiliary power supply 24V Auxiliary power supply 110V Sole auxiliary power supply 22...36VAC and 19...70VDC Sole auxiliary power supply 44...130VAC and 70...240VDC Dimensions mm VOLTMETERS + FREQUENCYMETERS 230 -24 110 -P1 -P2 1RIMD2AV... 85,50 93,75 93,75 144,00 144,00 2DIN MODULAR VERSION Frequency: 45÷100 Hz Class 0,5% ±2 digit referred to the end scale value 2 displayes, 3 digit red colour. Digit height 10 mm Input: 250V max Standard auxiliary power supply 230V Auxiliary power supply 24V Auxiliary power supply 110V Sole auxiliary power supply 22...36VAC and 19...70VDC Sole auxiliary power supply 44...130VAC and 70...240VDC Dimensions mm 230 -24 110 -P1 -P2 1RIMD2VF250... 113,30 123,60 123,60 172,00 172,00 2DIN DOUBLE THREE PHASE INSTRUMENTS VOLTMETERS + AMMETERS MODULAR VERSION Class 0,5% ±2 digit referred to the end scale value 3 displayes, 3 digit red colour. Digit height 7 mm Ammeter range between 5 to 999A with 5A steps, selectable by the front button Input 5A - it is necessary to connect the CT .../5A correspondent to the end scale value setted Voltmeter range (phase-neutral) 290V max Voltmeter range (phase-phase): 500V max Standard auxiliary self power supply 230V Dimensions 1RIMD23AV 118,45 2DIN 29 03 listino GB multifunzione prezzi ITA:listino ITA 15/11/10 16:16 Pagina 30 NETWORK ANALYSER MODULAR AND SWITCHBOARD VERSION Power supply: 230V ± 10% Protocoll: MODBUS SLAVE RTU Memory EEPROM 2kbyte Accuary class: 0,5% for voltages phase-neutral and currents - 1,5% for voltages phase-phase - 0,3% for frequency - 1% other parameters ±2 digit Serial communication RS 485 (2 wires opto insulated) present on the analyser with the possibility of 255 address monitoring Voltage input: three inputs between 0..150V - 0..300V - 0..500V end scale (for inputs 100V by means voltage transformer, select 150V) Current input 5A RMS with possibility to choose the current transformer up to 10.000/5A Inputs: 4, optoinsulated used for to count external impulses. Voltage from 10 to 30 VDC Outputs: 2, by N.O. reed relays 0,5A/100V Electrical parameters Voltage (RMS) phase-neutral, Voltage (RMS) phase-phase, Current (RMS), Active Power, Reactive Power, Frequency, Apparent Power, Power Factor, Total Active Power, Total Reactive Power, Total Apparent Power, Total Power Factor, Harmonic distorsion (numerical and graphic), Total harmonic distorsion, Voltage crest factor, Current crest factor, Active Energy in 4 tarifs (positive and negative), Reactive Energy in 4 tarifs (positive and negative) Dimensions 1RANM8N 2RAN968N 618,00 587,10 8DIN 96x96 ANALOGUE OUTPUT MODULES Selection of analogue output between 0-20mA; 4/20mA: 0-10V; 0-5V through the minidips situated under the cover 2 outputs are galvanically insulated from the other 2 and all are galvanically insulated from output RS485 Power supply 230 VAC Communication MODBUS RS485 RTU Selection of 4 positive DC outputs Selection of 4 positive and negative DC outputs 1RUAN3 . PRICES ON REQUEST 1RUAN4 . MULTIFUNCTION INSTRUMENTS LED - TRUE RMS SINGLE PHASE MODULAR VERSION The single phase multifunction meter that work as PRIORITY RELAY also in civil or industrial field Nominal input values: Voltage 300V Max; Current Max 32A direct insertion; Current by means of CT 5A insertion - Frequency form 50 to 60 Hz Standard power supply: 230 VAC 50/60Hz Dimensions: 2 DIN modules Class 2% ±2 digit for energy and power factor measures 1% ±2 digit for power measure 0,5% ±2 digit for voltage and current measure 0,3% ±1 digit for frequency Electrical parameters (* Settable parameter) Voltage phase-neutral, Current (direct insertion), Power Factor, Active Power, Active Energy *, Partial working hours *, Acoustic pre-alarm, OUTPUT relay N.C. (16A-250V-2500VA) Voltage phase-neutral, Current (insertion by means of CT), Power Factor, Apparent Power, Active Power, Reactive Power, Frequency, Active Energy *, Reactive Energy *, Partial working hours *, OUTPUT relay N.A. (10A-250V-2500VA) THREE PHASE MODULAR AND SWITCHBOARD VERSION 1RANM2 74,15 84,45 + OPTION “SPLIT CURRENT CT” Selectable capacities: from 5A to 1000A with steps of 5A – from 1000A to 6000A with steps of 50A Class: 2% ± 2 digit (Power and Energy) 0,5% ± 2 digit (all other values) Nominal input values Voltage 500V; Frequency from 40 to 60 Hz Primary current from 5A to 6000A selectable by button located at the front Secondary current 5A (1A on request) Memory: EEPROM Measures reading in True RMS up to 20th harmonic wave These codes (....-C100) are supplied together with a mini split core transformer in class 1 able to measure up to 100A and powers up to 23kW single phase. This solution permits a quick installation in already existing panels or nets as that it is not necessary to disconnect the power cable as needed by the classic current transformers. This CT accepts a cable diameter 12mm maximum and its position on the cable doesn’t influence the readings. Electrical parameters (* Settable parameter) 1RANM23 Voltage phase-phase, Voltage phase-neutral, Medium phase voltage, Current, Medium phase current, Current on neutral, Phase Active Power (+/-), Total Active Power (+/-), Phase Reactive Power, Total Reactive Power, Phase Apparent Power, Total Apparent Power, Total Active Energy, Total Active Energy (import) *, Total Active 149,35 Energy (export) *, Total Reactive Energy *, Partial and Total working hours *, Power Factor, Total equivalent Power Factor, Frequency, Phase sequence, Phase-Neutral voltage asimmetry, Standard selfpower supply: 230 VAC 50/60Hz 230 Power supply 230VAC Sole power supply 22....36VAC and 19....70VDC -P1 Sole power supply 44....130VAC and 70....240VDC -P2 With RS485 output, power supply 230VAC 230 With RS485 output, sole power supply 22....36VAC and 19....70VDC -P1 With RS485 output, sole power supply 44....130VAC and 70....240VDC -P2 Option “Split current CT” suffix ...C100 Extra price Dimensions 2DIN 30 1RANM2CT L3 L2 L1 2RAN72C 2RAN96C 2RAN72C...C100 2RAN72C485 2RAN96C...C100 2RAN96C485 144,00 202,00 202,00 220,00 279,00 279,00 189,00 248,00 248,00 48,00 72x72 72x72 288,00 347,00 347,00 48,00 96x96 96x96 03 listino GB multifunzione prezzi ITA:listino ITA 15/11/10 16:16 Pagina 31 LED - STANDARD VERSION THREE PHASE MODULAR AND SWITCHBOARD VERSION Selectable capacities: from 5A to 1000A with steps of 5A – from 1000A to 6000A with steps of 50A Class: 2% ± 2 digit (Power and Energy) 0,5% ± 2 digit (all other values) Nominal input values Voltage 500V; Frequency from 40 to 60 Hz Primary current from 5A to 6000A selectable by button located at the front Secondary current 5A (1A on request) Memory: EEPROM Dimensions: 6 DIN modules and 96x96mm 1RANM6 1RANM6R 1RANM6C 1RANM6CS 1RANM6C485 Electrical parameters Voltage phase-phase Voltage phase-neutral Current Total Active Power Total Reactive Power Total Apparent Power Total Active Energy Partial Active Energy Total Reactive Energy Power factor Frequency Sequence of phases Partial and Total hourmeter Software is available, free of charge, on our internet address www.revalco.it TWO OUTPUT REED RELAYS NO (0,5A-1000V) PROTOCOLL MODBUS SLAVE RTU SERIAL OUTPUT Standard self power supply: 230 VAC 50/60Hz 2RAN96 • • • 2RAN96R • • • 2RAN96C • • • • • • • • • • • • • • 180,25 267,80 2RAN96CS • • • • • • • • • • • • • 2RAN96C485 • • • • • • • • • • • • • • 262,65 298,70 • RS485 288,40 1RANM6CS485 2RAN96CS485 • • • • • • • • • • • • • • • • RS485 345,05 2RAN96C232 • • • • • • • • • • • • • •• • RS232 345,05 LCD - TRUE RMS A.C. THREE PHASE MODULAR VERSION - 6 DIN OSCILLOSCOPE function Dimensions: 6 DIN modules or 96x96mm Nominal input values: Voltage 500V; Frequency 50/60 Hz Primary current between 5A to 6000A selectable by button located at the front; Secondary current 5A (1A on request) Class 2% ±2 digit for energy and power factor measures, 1% ±2 digit for power measure 0,5% ±2 digit for voltage and current measure, 0,3% ±1 digit for frequency Electrical parameters Voltage phase-neutral Voltage phase-phase Medium phase voltage Current Power Factor, Total equivalent Power Factor Apparent Power Total Apparent Power Active Power (+/-) Total Active Power (+/-) Reactive Power Total Reactive Power Frequency Total Active Energy (import) settable parameter Total Active Energy (export) settable parameter Total Reactive Energy settable parameter Total working hours settable parameter Partial working hours settable parameter Phase sequence Phase-Neutral voltage asimmetry TWO OUTPUT REED RELAYS N.O. (1000V-0,5A-20VA) MODBUS SLAVE RTU Baude rate 9600-19200-38400-56800-115200 BLUETOOTH ACCESS (max 10 meters - Class 2) Baude rate 115200 Software is available, free of charge, on our internet address www.revalco.it PERMANENT MEMORY FOR SET POINT AND ENERGY (EEPROM) Standard self power supply 230 VAC 50/60Hz Sole power supply 22....36VAC and 19....70VDC Sole power supply 44....130VAC and 70....240VDC 1RAEM • • • • • 1RAEMC • • • • • • • • • • • • • • • • • • • • • 1RAEMCS • • • • • • • • • • • • • • • • • • • • 1RAEMC485 • • • • • • • • • • • • • • • • • • • • • • 1RAEMCS485 • • • • • • • • • • • • • • • • • • • • • • • • 247,20 306,00 306,00 • • 247,20 306,00 306,00 • • 272,95 332,00 332,00 1RAEMBL485 • • • • • • • • • • • • • • • • • • • • • 230 -P1 -P2 216,30 275,00 275,00 • 226,60 285,00 285,00 • 679,80 738,00 738,00 31 03 listino GB multifunzione prezzi ITA:listino ITA 15/11/10 16:16 Pagina 32 A.C. THREE PHASE MODULAR VERSION - 4 DIN Nominal input values: Direct voltage or by VT Primary current from 5A to 6000A selectable by button located at the front Secondary current 5A (1A on request) Frequency from 50 to 60 Hz Class 2% ±2 digit for energy and power factor measures, 1% ±2 digit for power measure 0,5% ±2 digit for voltage and current measure, 0,3% ±1 digit for frequency These codes (....-C100) are supplied together with a mini split core transformer in class 1 able to measure up to 100A and powers up to 23kW single phase. This solution permits a quick installation in already existing panels or nets as that it is not necessary to disconnect the power cable as needed by the classic current transformers. This CT accepts a cable diameter 12mm maximum and its position on the cable doesn’t influence the readings. Electrical parameters 3 phase-to-phase voltages, direct or from VT (optional) 3 phase-to-neutral voltages, direct or from VT (optional) 3 currents from CT..../5A (1 decimal) Current in neutral from CT..../5A (1 decimal) Frequency with 2 decimals 3 x Active Powers with 4 dialsi Total Active Powers with 4 dials 3 x Reactive Powers with 4 dials Total Reactive Powers with 4 dials 3 x Apparent Powers Total Apparent Power Power Factor of the 3 phases Total Power Factor Total Active Energy (import) resettable parameter Total Active Energy ( export) resettable parameter Total Reactive Energy resettable parameter Total operation counter Partial operation counter resettable parameter Programmable threshold with “NO” relay output 500mA/1000V Threshold status summary page Threshold activation signal Indication of the correct voltage phase sequence Indication of failed voltage supply RS485 3kV optoinsulated high-speed 5-speed interface MODBUS RTU SLAVE PROTOCOL Full compliance Keypad configurable settings Remote configurable settings Remote resetting of the energies Remote resetting of the partial counter Remote relay output control (if the threshold is OFF) Configurable password for access to programming Restore factory settings Programming of initial page upon start-up Programming of CT.../5A of 5 to 6000A with step of 5A Programming of VT (optional) with double indication L-L and L-N Programming of the analog average (V, A and P) Download the software for free from our website www.revalco.it Standard self power supply 230 VAC 50/60Hz Sole power supply 22....36VAC and 19....70VDC Sole power supply 44....130VAC and 70....240VDC Option “Split current CT” suffix ...C100 32 230 -P1 -P2 Extra price 1RAEM4C 1RAEM4C-C100 • • • • • 1RAEM4CS 1RAEM4CS-C100 • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • 150,00 208,00 208,00 48,00 170,00 229,00 229,00 48,00 L3 1RAEM4C485 1RAEM4C485-C100 • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • 195,00 254,00 254,00 48,00 L2 L1 1RAEM4CS485 1RAEM4CS485-C100 • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • 215,00 274,00 274,00 48,00 03 listino GB multifunzione prezzi ITA:listino ITA 15/11/10 16:16 Pagina 33 THREE PHASE A.C. DIRECT INPUT MODULAR VERSION - 4 DIN These instruments are compatible with the correspondent currents of magneto-thermic switches present on the distribution boards and requested by the market. Nominal input values: Direct current Class 2% ±2 digit for energy and power factor measures, 1% ±2 digit for power measure 0,5% ±2 digit for voltage and current measure, 0,3% ±1 digit for frequency 1RAEM463C - direct insertion 63A - direct insertion 32A - direct insertion 16A - direct insertion 10A 1RAEM432C 1RAEM416C 1RAEM410C 3x voltages Phase-phase • Medium voltage three-phase • Voltage asimmetry • 3 phase-to-neutral voltages • 3x currents, 2 decimals • Medium current, 2 decimals • Current in neutral, 2 decimals • Frequency with 2 decimals • 3 x Active Powers, 4 dials • Total Active Powers, 4 dials • 3 x Reactive Powers, 4 dials • Total Reactive Powers, 4 dials • 3 x Apparent Powers • Total Apparent Power • Power Factor of the 3 phases, 4 dials • Total Power Factor, 4 dials • Total Active Energy (import / export) resettable parameter • Total Reactive Energy resettable parameter • Total operation counter • Partial operation counter resettable parameter • Programmable threshold with “NO” relay output 500mA/1000V Threshold status summary page / Threshold activation signal RS485 3kV optoinsulated high-speed 5-speed interface MODBUS RTU SLAVE PROTOCOL Full compliance Remote configurable settings Remote resetting of the energies / partial counter Indication of the correct voltage phase sequence / Indication of failed voltage supply • Keypad configurable settings • Configurable password for access to programming • Restore factory settings • Programming of initial page upon start-up • Programming of the analog average (V, A and P) • Download the software for free from our website www.revalco.it • Standard self power supply 230 VAC 50/60Hz 230 200,00 Sole power supply 22....36VAC and 19....70VDC -P1 258,00 Sole power supply 44....130VAC and 70....240VDC -P2 258,00 1RAEM463CS 1RAEM432CS 1RAEM416CS 1RAEM410CS • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • 250,00 308,00 308,00 • • • • • • • 215,00 273,00 273,00 1RAEM463C485 1RAEM432C485 1RAEM416C485 1RAEM410C485 • • • • • • • • • • • • • • • • • • • • • • • • • • • • • 265,00 323,00 323,00 D.C. SINGLE PHASE • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • 245,00 304,00 304,00 • • • • • • • • • • • 295,00 354,00 354,00 MODULAR VERSION - 4 DIN Nominal input values: Class DC voltage 800v maximum (or by external divider .../100V) Primary current from 5A to 3000A selectable by button located at the front Secondary 60 mV DC 2% ±2 digit for energy and power factor measures, 1% ±2 digit for power measure 0,5% ±2 digit for voltage and current measure, 0,3% ±1 digit for frequency DC Voltage 800.0 V max DC Voltage ..../100V by divider DC Current .../60mV Bidirectional power (kW) Total active energy (Import/ Export) resettable parameter Ampère-hour Ah+ (Import) resettable parameter Ampère-hour Ah- (Export) resettable parameter Total working hours Partial working hours settable parameter Indication of failed voltage supply Programmed threshold V-A-W Output relay NO (500mA/1000V) Threshold activation signal / Threshold status summary page Interface RS485 3kV optoinsulated 9600...115200bps MODBUS SLAVE RTU full compliance Remote configurable settings Keypad configurable settings Remote resetting of energies - ampere/hour - counter Remote relay output control (if the threshold is OFF) Configurable password for access to programming Restore factory settings Programming of initial page upon start-up Programming of current 5 to 3000ADC with step of 5A Programming of voltage from 10 to 3000.0VDC step 1V Programming of analog average (VDC, ADC and W) Download the software for free from our website www.revalco.it Standard self power supply 230 VAC 50/60Hz 230 Sole power supply 22....36VAC and 19....70VDC -P1 Sole power supply 44....130VAC and 70....240VDC -P2 1RAEM4C DC 1RAEM4C SDC 1RAEM4C 485DC 1RAEM4C S485DC • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • 250,00 308,00 308,00 270,00 329,00 329,00 • • 295,00 354,00 354,00 • • 315,00 374,00 374,00 • • • • • 1RAEM4C HDC • • • • • • • • • 1RAEM4C 1RAEM4C 1RAEM4C HSDC H485DC HS485DC • • • • • • • • • • • • • • • • • • • • • • • • • • 300,00 358,00 358,00 320,00 379,00 379,00 • • • • • • • • • • • • • • • • • • • • • 345,00 404,00 404,00 • • • • • • • • • • • • • • • • • • • • • • • • • 365,00 424,00 424,00 33 03 listino GB multifunzione prezzi ITA:listino ITA 15/11/10 16:16 Pagina 34 THREE PHASE SWITCHBOARD VERSION Nominal input values: Voltage 500V; Frequency 50/60 Hz Primary current between 5A to 6000A selectable by button located at the front; Secondary current 5A Instruments available with secondary current 1A and prices on request. The ordering code is obtained changing ..L4.. with ..L1... Example: 2RAE96L1C Class 2% ±2 digit for energy and power factor measures, 1% ±2 digit for power measure 0,5% ±2 digit for voltage and current measure, 0,3% ±1 digit for frequency Dimensions 72x72 or 96x96 mm 2RAE96L7C.... VT..../100V insertion, 3 or 4 wires, 2 or 3 systems Standard self power supply 230 VAC 50/60Hz Sole power supply 22....36VAC and 19....70VDC Sole power supply 44....130VAC and 70....240VDC Standard self power supply 230 VAC 50/60Hz - 7 Displayes Sole power supply 22....36VAC and 19....70VDC - 7 Displayes Sole power supply 44....130VAC and 70....240VDC - 7 Displayes VT..../100V insertion, 3 or 4 wires, 2 or 3 systems Standard self power supply 230 VAC 50/60Hz Sole power supply 22....36VAC and 19....70VDC Sole power supply 44....130VAC and 70....240VDC Standard self power supply 230 VAC 50/60Hz - 7 Displayes Sole power supply 22....36VAC and 19....70VDC - 7 Displayes Sole power supply 44....130VAC and 70....240VDC - 7 Displayes *Option Ethernet from serial transducer: suffix ETH2S *Option Ethernet from web server: suffix ETH2WS *Option Profibus: suffix PROF 34 230 -P1 -P2 230 -P1 -P2 • 236,90 288,40 288,40 . . . • 257,50 309,00 309,00 . . . 230 -P1 -P2 230 -P1 -P2 2RAE96L4CH1 2RAE72L4CH1 2RAE96L7CH1 236,90 288,40 288,40 . . . Primary Voltage up to 9,9kV 230 -P1 -P2 230 PRICES ON -P1 REQUEST -P2 2RAE96L4CH2 2RAE72L4CH2 2RAE96L7CH2 236,90 288,40 288,40 . . . Primary Voltage 10...100kV 230 -P1 -P2 230 PRICES ON -P1 REQUEST -P2 2RAE96L4CH3 2RAE72L4CH3 2RAE96L7CH3 236,90 288,40 288,40 . . . PRICES ON REQUEST PRICES ON REQUEST 2RAE96L7CS • • • • • • • • • • • • • • • • • • • • • 2RAE96L4C485* 2RAE96L4CS485* 2RAE72L4C485 2RAE96L7C485* 2RAE96L7CS485* • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • 257,50 283,25 309,00 334,75 309,00 334,75 . . . . . . 2RAE96L4CS485H1* 2RAE72L4C485H1 322,50 374,00 374,00 2RAE96L7CS485H1* 283,25 334,75 334,75 . . . 2RAE96L4CS485H2* 2RAE72L4C485H2 322,50 374,00 374,00 2RAE96L7CS485H2* 283,25 334,75 334,75 . . . 2RAE96L4CS485H3* 2RAE72L4C485H3 Aux supply 230VAC Aux supply -P1 (22....36VAC and 19....70VDC) or -P2 (44....130VAC and 70....240VDC) Aux supply 230VAC Aux supply -P1 (22....36VAC and 19....70VDC) or -P2 (44....130VAC and 70....240VDC) 322,50 374,00 374,00 2RAE96L7CS485H3* 283,25 334,75 334,75 . . . Extra price Extra price Extra price Extra price Extra price . . . . . PR I EQ CE U SO ES N T 400V insertion, 3 or 4 wires, 2 or 3 systems Standard self power supply 230 VAC 50/60Hz Sole power supply 22....36VAC and 19....70VDC Sole power supply 44....130VAC and 70....240VDC Standard self power supply 230 VAC 50/60Hz - 7 Displayes Sole power supply 22....36VAC and 19....70VDC - 7 Displayes Sole power supply 44....130VAC and 70....240VDC - 7 Displayes 2RAE96L4CS R Electrical parameters Voltage phase-neutral Voltage phase-phase Medium phase voltage Current Power Factor Total equivalent Power Factor Apparent Power Total Apparent Power Active Power (+/-) Total Active Power (+/-) Reactive Power Total Reactive Power Frequency Total Active Energy (import) settable parameter Total Active Energy (export) settable parameter Total Reactive Energy settable parameter Total working hours settable parameter Partial working hours settable parameter Phase sequence Phase-Neutral voltage asimmetry TWO OUTPUT REED RELAYS N.O. (1000V-0,5A-20VA) MODBUS SLAVE RTU Baude rate 9600 - 19200 - 38400 - 56800 - 115200 PERMANENT MEMORY FOR SET POINT AND ENERGY (EEPROM) Standard self power supply 230 VAC 50/60Hz Sole power supply 22....36VAC and 19....70VDC Sole power supply 44....130VAC and 70....240VDC Standard self power supply 230 VAC 50/60Hz - 7 Displayes Sole power supply 22....36VAC and 19....70VDC - 7 Displayes Sole power supply 44....130VAC and 70....240VDC - 7 Displayes 2RAE96L4C 2RAE72L4C 2RAE96L7C • • • • • • • • • • • • • • • • • • • • 03 listino GB multifunzione prezzi ITA:listino ITA 15/11/10 16:16 Pagina 35 COMPUTER INTERFACE MODULAR VERSION Power supply: 230V +/- 10% 50/60Hz Dimensions: 3 DIN modules Serial, bidirectional selectable communication RS 232 / RS 422 and RS 232 / 485 1RINT 226,60 CABLE VERSION The USB serial converter permits the installation of a virtual serial port (COM) by the use of a PC USB port. New installed port will be “seen” by the operative Windows system as an additional COM port and it can be used in every application. This device is supplied in a standard kit which includes: 232 adapter cable able to create the virtual serial port starting from an USB port. Software driver for Windows XP and Windows Vista. Software present on our web site www.revalco.it RINTC 221,45 RS232 to RS485 interface ETHERNET VERSION Power supply: Baud rate Protocols Dimensions and weight Data interface 10-30VDC 1.2W from 1200bps to 115Kbps ARP,UDP, TCP, ICMP, HTTP, DHCP, IP 75x150x25 mm - 240g Ethernet RJ45 10Mbps - RS232 (removable terminals) - RS422/485 (removable terminals) 2TRP 695,25 35 1RANM8N 2RAN968N DC Voltage 800 V max DC Voltage ..../100V by divider DC Current .../60mV Bidirectional power (kW) Bidirectional Total Energy (import/export) Bidirectional Ampere-hour Ah (import/export) Harmonic distorsion • Total Harmonic distorsion • Voltage / Current crest factor • Active Energy 4 tarifs (+/-) • Reactive Energy 4 tarifs (+/-) • Total integration time (15min) 10,15,20,30,60min selectable Voltage phase-neutral • Voltage phase-phase • Medium phase voltage • Current (direct insertion) Current (insertion by CT) • Current on neutral • Medium Current • Power Factor • Total Power Factor • Apparent Power • Total Apparent Power • Active Power (+/-) • Total Active Power (+/-) • Reactive Power • Total Reactive Power • Frequency • Total Active Energy (import) resettable • Relative Active Energy • Total Active Energy (export) resettable • Total Reactive Energy resettable • Total working hours • Partial working hours resettable • Acoustic pre-alarm Phase sequence • Voltage asimmetry OUTPUT RELAY (alarm threshold) • MODBUS SLAVE RTU RS232 MODBUS SLAVE RTU RS485 • BLUETOOTH ACCESS (max 10 meters - Class 2) Baude rate 115200 PERMANENT MEMORY (EEPROM) • selectable 400V insertion, 3 or 4 wires, 2 or 3 systems (H1) selectable VT..../100V, 3 or 4 wires, 2 or 3 systems (0...9,9kV) (H2) VT..../100V, 3 or 4 wires, 2 or 3 systems (10...100kV) (H3) selectable Software on www.revalco.it • Option Split Core CT (up to 100A) Option ETHERNET or PROFIBUS Dimensions in mm 8 DIN / 96x96 1RANM2 • 2 DIN • • • 1 • • 1 • • • • • • • • • 2 • • • • • • • • • • • • • • 6 DIN / 96x96 • • • • • • • • • • • • • • • • 2 • • • • • • • • • • • • • • • • • • • • • • • • • • • 2 • 1RANM6C 2RAN96C • • 1RANM6CS 2RAN96CS • • 1RANM6R 2RAN96R • • 1RANM6C485 2RAN96C485 • • 1RANM6 2RAN96 • • 1RANM6CS485 2RAN96CS485 • • • • • • • • • • • • • • • • • • • • • • 2RAN72C485 2RAN96C485 2RAN...C485-C100 72x72 / 96x96 • • • • • • • • 2 DIN • • • • • • • • • • • • • • • 2RAN72C 2RAN96C 2RAN...C-C100 • • • • • • • • • • • • • • • • • 1RANM23 • 1RANM2CT • • • 6 DIN • 2 • • • • • • • • • • • • • • • 1RANM6C232 • • • 1RAEM • • • • • • • • • • • • • • • • • • • • 1RAEMCS • 2 • • • • • • • • • • • • • • • • • • • • • • • • • • 2 • • • • • • • • • • • • • • • • • • • • • • • • • • 1RAEMCS485 • • • • • • • • • • • • • • 1RAEMC485 6 DIN / 96x96 1RAEMC • • • 1RAEMBL485 • • • • 2 • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • 1RAEM4C 1RAEM4C-C100 PARAMETERS TABLE • • 1 • • • • • • • • • • • • • • • 1RAEM4CS 1RAEM4CS-C100 MULTIFUNCTION METERS THREE PHASE A.C. AND SINGLE PHASE D.C. VERSIONS • • • • • • • • 1 • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • 1RAEM4C485 1RAEM4C485-C100 SINGLE PHASE 1RAEM4CS485 1RAEM4CS485-C100 NETWORK ANALYSER THREE PHASE 1 • 4 DIN • • • • • • • • 1 1RAEM4CDC 1RAEM4CSDC 1RAEM4C485DC 1RAEM4CS485DC • 1 • • • • • 1 1RAEM4CHDC 1RAEM4CSHDC 1RAEM4C485HDC 1RAEM4CS485HDC • • • • • 1RAEM410CS - 1RAEM416CS 1RAEM432CS - 1RAEM463CS • • 1 1 • • • • • • • • • • • • • • • • • • • • • • • • • 1RAEM410C485 - 1RAEM416C485 1RAEM432C485 - 1RAEM463C485 • • • • • • • • • • • • • • • • • • • • • • 2RAE96L4CS • 2 • • • • • • • • • • • • • • • • • • • • • 96x96 • 96x96 • • • • • • • 2 • • • • • • • • • • • • • • • • • • • • 2RAE96L4CS485 • • • • • • • • • • • • • • • • • • • • • • 2RAE96L4C485 2RAE72L4C485 72x72 / 96x96 2RAE96L4C 2RAE72L4C • • • 03 listino GB multifunzione prezzi ITA:listino ITA 15/11/10 16:16 Pagina 36 1RAEM410C - 1RAEM416C 1RAEM432C - 1RAEM463C 04 listino GB cont_energia prezzi ITA:04 nuovo listino ITA cont_energia 15/11/10 16:17 Pagina 37 ENERGY kWh METERS "MID" NORMATIVE EN50470-1, EN50470-3, EN62059-41 Taken from the Official Gazette of the European Union The requisites of attachment I, the specific requisites of this attachment and the assessment and conformity procedures listed in this attachment, are applied to active electric energy meters destined for residential, trade and light commercial uses. Note: the electric energy meters can be used together with the external transformers, depending on the measuring technique applied. However, this attachment takes into account only electric meters and not the transformers. DEFINITIONS: An active electric energy meter is a device which measures the active electric energy used in a circuit I= intensity of electric current which circulates in the meter Itr = I value above which the error is kept within the tolerable minimum limits corresponding to the class index of the meter. Transition current In = specified reference current for which the transformer in function has from which the KWh is in class within minimum limits been planned Imax = I maximum value for which the error remains within the tolerable Ist = minimum I declared value in correspondence of which the meter starts maximum limits to count the active electric energy at unit power factor (balanced load U = electric energy voltage supplied to the meter polyphase meters), but it is not in class Ufn = specified reference electric energy voltage Imin = I value above which the error is kept within the tolerable maximum limits (balanced load polyphase meters). Minimum function current in f= electric voltage frequency supplied to the meter class within the maximum limits from Ist to Itr fn = specified reference frequency Iref = reference current (ex Ib) PF = power factor = cosφ = phasing cosφ between I and U SPECIFIC REQUISITES 1. Accuracy: the manufacturer specifies the class index of the meters. The class indexes are defined as follows: Class A, Class B and Class C. 2. Nominal functioning conditions: the manufacturer specifies the nominal functioning conditions of the meter, in particular the values of: fn , Un, In, Ist, Imin, Itr, Imax applicable to the meter. For the chosen values, the meter must satisfy the conditions in the following table: Class A Class B Class C For meters with direct connection Iref 10xItr Itr Imax /50 Ist ≤ 0,05 x Itr ≤ 0,04 x Itr ≤ 0,04 x Itr Imin ≤ 0,5 x Itr ≤ 0,5 x Itr ≤ 0,3 x Itr Imax ≥ 50 x Itr ≥ 50 x Itr ≥ 50 x Itr For meters functioning through a transformer Itr In/20 Ist ≤ 0,06 x Itr ≤ 0,04 x Itr ≤ 0,02 x Itr Imin ≤ 0,4 x Itr ≤ 0,2 x Itr (*) ≤ 0,2 x Itr In = 20 x Itr = 20 x Itr = 20 x Itr Imax ≥ 1,2 x In ≥ 1,2 x In ≥ 1,2 x In (*) For electromechanical meters Imin of class B apply ≤ 0,4 x Itr EXAMPLE: for class A monophase direct meters (Gazette EU-L135/51-30.04.2004-Table 1) = (EN50470-1:2006-Table 3) - Standard values V = 230/400V (EN50470-1:2006-Table 1) Standard values Itr = 0.5-1-1.5-2A (EN50470-1:2006-Table 2) Imax X Pre-fixed Standard values F = 50Hz (EN50470-1:2006-4.3) Max current measure circuit consumption at Iref = 2.5VA ± 2% cosφ 0,5-1-0,8 (EN50470-3:2006-Table 4) (EN50470-3:2006-Table 2) Iref = 10 x Itr - Measuring points to evaluate the % error (at least 3 measures per point = Imin, Itr, Iref, Imax (EN50470-3:2006-Table 13) ≤ Imax / 50 Itr - Monophase absolute errors (EN50470-3:2006-Table 4): X X ± 2,5% cosφ 1 (EN50470-3:2006-Table 4) between Imin and Itr only cosφ 1 = ± 2.5%; between Itr and Imax Imin ≤ Itr / 2 X cosφ 0.5-1-0.8 = ± 2% Ist ≤ Itr / 20 (EN50470-3:2006-Table 15) - Polyphase absolute errors with balanced voltage and load on single phase only between Itr and Imax cosφ 0.5-1 (no C)= ± 3% 0 (EN50470-3:2006-Table 5) - Additional errors due to the temperature (EN50470-3:2006-Table 6): between Imin and Imax cosφ 1 = ± 1.8%; between Itr and Imax cosφ 0.5-1-0.8 = ± 2.7% - Additional errors due to the voltage variation ± 10% (EN50470-3:2006-Table 6): between Imin and Imax cosφ 1 = ± 1%; between Itr and Imax cosφ 0.5-1-0.8 = ± 1.5% - Additional errors due to the frequency variation ± 2% (EN50470-3:2006-Table 6): between Imin and Imax cosφ 1 = ± 0.8%; between Itr and Imax cosφ 0.5-1-0.8 = ± 1% - In 5°C... 30°C range, the total sum of errors cannot exceed ± 3.5% (EN50470-3:2006-Table 8) DETAILS FOR ORDERING CHANGE FROM A 4 MODULES METER TO A 96x96 METER The three-phase energy meters are calibrated with the following standard values: Input in 5A current and primary selected through minidip; Input in 400V voltage Upon request, it is possible to calibrate the meters with the following parameters which are to be indicated when ordering: Input 1A current; Input under voltage:100/√3/V, 110/√3V, 100V, 110V, 230V, 440V, 500V ARAD964 + "MID" Meter with 4 modules = "MID" 96x96 Meter SELECTION OF CURRENT TRANSFORMERS AND OUTPUT IMPULSES - 96x96 meters Minidip view from behind the instrumen Max 1500A 1 impulse = 100 Wh 1 impulse = 1 Rear panel kWh 1 impulse = 10 kWh SELECTION OF CURRENT TRANSFORMERS AND OUTPUT IMPULSES - 4 modules meters Minidip view from behind the instrument Max 4000A 37 04 listino GB cont_energia prezzi ITA:04 nuovo listino ITA cont_energia 15/11/10 16:17 Pagina 38 SELECTION OF CURRENT TRANSFORMERS AND OUTPUT IMPULSES - 6 modules meters Minidip view from behind the instrument Max 4000A 1 impulse = 100 Wh 1 impulse = 1 kWh 1 impulse = 10 kWh SINGLE-PHASE DC kWh-METERS MODULAR VERSION Power supply Accuracy class Display Nominal current Maximum admitted current Output impulses 48V DC (40 ÷ 54 V DC) selfsupplied 2 99999,99 kWh (5 entires + 2 decimals) DC from external shunt (....A/60mV) the value of primary current must be indicated during the order between: 30A - 40A - 50A - 60A - 80A - 100A - 120A - 150A 1,2 In Open-Collector System (SO, DIN43864), Max 36V/20mA DC - impulse duration 100 ms PRICES ON REQUEST Dimensions 2 DIN 1RCEM2C . SINGLE-PHASE ACTIVE ENERGY kWh-METERS MODULAR AND SWITCHBOARD VERSION Class A (Class 2 for switchboard version) Nominal current 5A, Nominal voltage 230V, relay NO 0,5A/100V, Impulse duration 100ms Max current 30A, Nominal voltage 230V, Output pulse Open Collector max 60VDC/30mADC, Impulse duration >80ms Max current 30A, Nominal voltage 230V, Output pulse Open Collector max 36V/20mADC, Impulse duration 100ms With sealable case and terminals for certification Max current 30A, Output pulse Open Collector max 36V/20mADC, Impulse duration 100ms Max current 63A, Output pulse Open Collector max 60VDC/30mADC, Impulse duration >80ms Nominal current 5A, Nominal voltage 230V, relay NO 0,5A/100V, Impulse duration 100ms Display (entires + decimals) Dimensions DIGITAL DISPLAY 1RCEM41 1RCEM41D 206,00 230,00 DIGITAL DISPLAY 1RCEM1 1RCEM2 1RCEM2D 66,95 84,00 DIGITAL DISPLAY 1RCEM3U 1RCEM263 1RCEM263D 2RCEM96230 66,95 119,20 6+1 4DIN 6+1 4DIN 5+2 1DIN 5+2 2DIN 5+2 2DIN 133,90 154,00 6+1 2DIN 6+1 2DIN 5+2 3DIN 339,90 6+1 96x96 THREE-PHASE ACTIVE ENERGY kWh-METERS 3 WIRES WITHOUT NEUTRAL (ARON) - INSERTION ON CT 5A Output pulse Open Collector, max 60VDC/30mADC, Impulse duration >80ms (for 1RCTM354 model) Class A (Class 2 for switchboard version) Nominal current 5A Nominal voltage 3x230V / 400V Relay NO, 0,5A / 100V; Impulse duration 100 ms Dimensions 4DIN Dimensions 4DIN for certification Dimensions 6DIN Dimensions 6DIN, with sealable terminals for certification Dimensions 96x96mm Dimensions 96x96mm, with sealable terminals for certification Display (entires + decimals) 38 MODULAR AND SWITCHBOARD VERSION DIGITAL DISPLAY 1RCETM354 226,60 1RCETM354U 1RCETM354D 250,00 242,00 1RCETM35 1RCETM35U 2RCET9635 2RCET9635U 267,80 283,25 309,00 6+1 6+1 6+1 6+1 6+1 6+1 334,75 6+1 04 listino GB cont_energia prezzi ITA:04 nuovo listino ITA cont_energia 15/11/10 16:17 Pagina 39 4 WIRES WITH NEUTRAL - INSERTION ON CT 5A Output pulse Open Collector, max 60VDC/30mADC, Impulse duration >80ms (for 1RCTM454 model) Class A (Class 2 for switchboard version) Nominal current 5A Nominal voltage 3x230V / 400V Relay NO, 0,5A / 100V, Impulse duration 100 ms Display (6 entires + 1 decimal) Dimensions 4DIN Dimensions 4DIN for certification Dimensions 6DIN Dimensions 6DIN, with sealable terminals for certification Dimensions 96x96mm Dimensions 96x96mm, with sealable terminals for certification 1RCETM454 221,45 MODULAR AND SWITCHBOARD VERSION DIGITAL DISPLAY 1RCETM454U 1RCETM454D 250,00 237,00 1RCETM45 1RCETM45U 2RCET9645 2RCET9645U 267,80 283,25 309,00 334,75 4 WIRES WITH NEUTRAL - DIRECT INSERTION 30A MODULAR VERSION DIGITAL DISPLAY Class A (Class 2 for 1RCETM430 model) Max current 32A Nominal voltage 3x230V / 400V Relay NO, 0,5A / 100V, Impulse duration 100 ms Output pulse Open Collector, max 60VDC/30mADC, Impulse duration >80ms (for 1RCTM304 model) Display (6 entires + 1 decimal) 1RCETM304 221,45 Dimensions 4DIN Dimensions 6DIN 1RCETM304D 240,00 1RCETM430 309,00 4 WIRES WITH NEUTRAL - DIRECT INSERTION 63A MODULAR VERSION DIGITAL DISPLAY Class A Max current 63A Nominal voltage 3x230V / 400V Output pulse Open Collector, max 60VDC/30mADC, Impulse duration >80ms Display (6 entires + 1 decimal) 1RCETM63 242,05 Dimensions 4DIN Dimensions 4DIN for certification 1RCETM63U 1RCETM63D 260,00 258,00 THREE-PHASE REACTIVE ENERGY kWh-METERS INSERTION ON CT 5A MODULAR AND SWITCHBOARD VERSION Class 3 Nominal current 5A Nominal voltage 400V Relay NO, 0,5A / 100V, Impulse duration 100 ms Display (6 entires + 1 decimal) 3 wires without neutral (ARON), Dimensions 6DIN 4 wires with neutral, Dimensions 6DIN 3 wires without neutral (ARON), Dimensions 96x96mm 4 wires with neutral, Dimensions 96x96mm 1RCETRM35 324,45 1RCETRM45 2RCETR9635 2RCETR9645 324,45 324,45 324,45 kWh-METERS WITH MINIMUM LOAD THRESHOLD AND ENABLING FOR HOUR-METER CERTIFIABLE (FISCAL USE) INSERTION ON CT 5A MODULAR AND SWITCHBOARD VERSION DIGITAL DISPLAY Class 2 (Class A for 1RCETM454C version) Nominal current 5A Nominal voltage 3x230V / 400V Relay NO, 0,5A / 100V, Impulse duration 100 ms Output pulse Open Collector, max 60VDC/30mADC, Impulse duration >80ms (for 1RCTM454C model) Dimensions 6DIN, with sealable terminals for certification Dimensions 4DIN, with sealable terminals for certification Dimensions 96x96mm, with sealable terminals for certification 1RCETM45C 309,00 1RCETM454C 1RCETM454CD 257,50 260,00 2RCET9645UC 339,90 39 04 listino GB cont_energia prezzi ITA:04 nuovo listino ITA cont_energia 15/11/10 16:17 Pagina 40 INDUCTION kWh-METERS MONOPHASE ACTIVE ENERGY - 2 WIRES Class 2 Current 5/20A Current 5/20A Current 5/20A Current 10/40A Current 20/80A 100V 230V 400V 230V 230V 3RCEMI5100 3RCEMI5230 3RCEMI5400 3RCEMI10230 3RCEMI20230 82,40 72,10 82,40 82,40 82,40 THREE-PHASE ACTIVE AND REACTIVE ENERGY - 2 SYSTEMS Classe 2 for Active Energy, Classe 3 for Reactive Energy 3 wires without neutral (ARON) Active Energy Current 5/20A Current 5/20A Current 10/40A Current 20/80A 2x100V 2x400V 2x400V 2x400V 3RCETI351 118,45 3RCETI354 118,45 Reactive Energy 3RCETI3104 3RCETI3204 3RCETRI351 3RCETRI354 164,80 154,50 118,45 118,45 THREE-PHASE ACTIVE AND REACTIVE ENERGY - 3 SYSTEMS Classe 2 for Active Energy, Classe 3 for Reactive Energy 4 wires with neutral Active Energy Current 5/20A Current 5/20A Current 10/40A Current 20/80A 3x100√3/100V 3x230/400V 3x230/400V 3x230/400V 3RCETI451 164,800 3RCETI454 144,20 Reactive Energy 3RCETI4104 3RCETI4204 3RCETRI451 3RCETRI454 185,40 185,40 164,800 144,20 SEALABLE TERMINALS Single phase meters Three phase meters - 2 systems Three phase meters - 3 systems Dimensions 95x85x48 mm Dimensions 170x85x48 mm Dimensions 245x85x48 mm ARMS1 175,10 ARMS2 ARMS3 236,90 309,00 UTF CERTIFICATIONS / CUSTOMS AGENCY Revalco is able to supply the certification of the measuring groups in case the Customs Technical Department requests it. The certification of the whole plant is to be requested at the competent UTF offices of the area. In case of a measuring group with three systems composed of 3 current transformers and one meter, 5 inspection certificates are necessary. When the measuring group to be inspected is a 2 system, 4 certificates are requested as the interested CT are only two. ACERT-U 123,60 RECORDERS OF IMPULSES 5 INPUTS WITH OUTPUT RS485 Device for the collection of impulses coming from: energy meters, water meters, gas meters, heat recorders, step count, people count, access count, piece count or any other count application equipped with a free relay count from potential or from an "Open Collector" (example: photocell or proximity sensor). The impulses received on the 5 independent channels can be counted inside the device so that the totals are available to a "Master" Modbus requesting it. The counting of every channel is deposited in appropriate dedicated registers, one for the totalisation and the others to supply "Weighed" measures Complete software available on our web site: www.revalco.it Power wupply 230V 40 1RCD5485 221,45 05 listino GB rele diff+aut+elett prezzi ITA:listino ITA 15/11/10 16:17 Pagina 41 EARTH LEAKAGE RELAYS MODULAR VERSION Earth leakage relay intervenes also after a loss of connection with the toroidal current transformer. It is possible to effect the remote reset simply by removing and applying again the auxiliary voltage supply. The Test and Reset buttons are accessible from the front with sealed front window also These earth leakage relays are developped to be used with toroids having ratio 50/0,1. For toroids with ratio 60/0,1 (1000/0,1) add suffix 60 (1000) to the standard code of earth leakage relays. Auxiliary power supply: 230V AC ± 10% - 40 / 60 Hz Output, one change-over contact 10A, 250V 1RDT1 Current selection (IΔN) 30 - 100 - 300 - 500 mA 1 - 3 A Time selection 0 - 4 sec Type A Current selection (IΔN) 30 - 50 - 100 mA (x10...x100) with incorporated toroid ø18mm Time selection 2 - 33 msec / 0,5 - 1,5 - 3 sec (summable) Type A Current selection (IΔN) 30 - 50 - 100 - 150 - 230 - 300 - 350 mA 0,5 - 1 - 1,5 - 2 - 3 A Type A Time selection 0 - 0,25 - 0,5 - 1 - 2 - 3 - 4 - 5 - 6 - 7 - 8 - 10 sec Current selection (IΔN) 30 - 100 - 300 mA 0,5 - 1 - 1,5 - 2 - 3 - 5 10 - 20 - 30 A Time selection 0 - 0,25 - 0,5 - 1 - 2 - 3 - 4 - 5 - 6 - 7 - 8 - 10 sec Type A Current selection (IΔN) 30 - 300 - 500 mA 1 - 3 - 30 A Time selection 0 - 1 - 2 - 3 - 4 sec Type A Current selection (IΔN) 30mA - 300mA - 3A Time selection 0 - 0,2 - 0,5 - 3 - 5 sec Type AC Sole power supply 22...36VAC and 19...70VDC PD1 Sole power supply 44...130VAC and 70...240VDC PD2 400Hz version suffix “H” Extra price Dimensions 1RDT1H 1RDT3 RDT30KC 1RDT30E 1RDT3S 84,00 110,00 112,25 112,25 100,40 +30 euro 1 DIN +30 euro 1 DIN 171,00 171,00 +30 euro 3 DIN 1RDT4 Current selection (IΔN) 30 - 300 - 500 mA 1 - 3 - 30 A 1 relay with 2 contacts Type A Time selection 0 - 1 - 2 - 3 - 4 sec Current selection (IΔN) 30 - 300 - 500 mA 1 - 3 - 30 A 2 change over relays Time selection 0 - 1 - 2 - 3 - 4 sec With prealarm threshold - Type A Current selection (IΔN) 30 - 100 - 150 - 200 - 300 - 500 mA Special toriod supplied together with the relay Time selection 0 - 10 sec with prealarm threshold and high sensibility from 2 to 65 Hz - Type A Current selection (IΔN) 30 - 50 - 100 - 150 - 230 - 300 - 350 mA 0,5 - 1 - 1,5 - 2 - 3 A Time selection 0 - 0,25 - 0,5 - 1 - 2 - 3 - 4 - 5 - 6 - 7 - 8 - 10 sec Type A Sole power supply 22...36VAC and 19...70VDC PD1 Sole power supply 44...130VAC and 70...240VDC PD2 400Hz version suffix “H” Extra price Dimensions 171,00 171,00 +30 euro 3 DIN 160,00 160,00 +30 euro 3 DIN 1RDT430E 1RDT4265E 100,40 160,00 160,00 +30 euro 3 DIN 1RDT4S 125,00 160,00 400,00 185,00 185,00 +30 euro 4 DIN 219,00 219,00 +30 euro 4 DIN 459,00 459,00 +30 euro 4 DIN 125,00 185,00 185,00 +30 euro 4 DIN SWITCHBOARD VERSION Earth leakage relay intervenes also after a loss of connection with the toroidal current transformer. It is possible to effect the remote reset simply by removing and applying again the auxiliary voltage supply. The Test and Reset buttons are accessible from the front with sealed front window also These earth leakage relays are developped to be used with toroids having ratio 50/0,1. For toroids with ratio 60/0,1 (1000/0,1) add suffix 60 (1000) to the standard code of earth leakage relays. Auxiliary power supply: 230V AC ± 10% - 40 / 60 Hz Output, one change-over contact 10A, 250V Dimensions 48x48, 72x72 and 96x96 mm 2RDT4848 2RDT7272 Current selection (IΔN) Time selection Current selection (IΔN) Time selection Current selection (IΔN) Time selection Current selection (IΔN) 30 - 300 - 500 mA 1 - 3 - 30 A 1 relay with 2 contacts 0 - 1 - 2 - 3 - 4 sec Type A 30 - 100 - 300 mA 0,5 - 1 - 3 - 10 - 30 A 0 - 0,25 - 0,5 - 1 - 2 - 3 - 4 - 5 - 6 - 7 - 8 - 10 sec Type A 30 - 300 - 500 mA 1 - 3 - 30 A 2 change over relays With prealarm threshold - Type A 0 - 1 - 2 - 3 - 4 sec 30 - 100 - 150 - 200 - 300 - 500 mA Special toriod supplied together with the relay Time selection 0 - 10 sec with prealarm threshold and high sensibility from 2 to 65 Hz - Type A Sole power supply 22...36VAC and 19...70VDC PD1 Sole power supply 44...130VAC and 70...240VDC PD2 400Hz version suffix “H” Extra price 190,00 2RDT72 2RDT96 123,60 128,75 2RDT96430E 2RDT96265E 203,00 175,00 475,00 248,00 248,00 +30 euro 261,00 261,00 +30 euro 195,70 195,70 +30 euro 200,85 200,85 +30 euro 234,00 234,00 +30 euro 534,00 534,00 +30 euro ADAPTER TOROIDAL CURRENT TRANSFORMERS Used to solve problem of earth leakage ralais connection when the bars are too big or far each other. Class 0,2 Power 1VA 5/0,1A 5+5+5/0,1A 5+5+5+5/0,1A TORAD 68,00 TORSD3 TORSD4 121,55 134,95 41 05 listino GB rele diff+aut+elett prezzi ITA:listino ITA 15/11/10 16:18 Pagina 42 TOROIDAL CURRENT TRANSFORMERS Suffix “R” version is used with very low currents relays (10mA) or high frequences (400Hz) Toroidal ratio: 50/0,1 A Numbers of turns: 500 Ø Internal 23 mm Ø hole 15 mm, modular Ø Internal 35 mm Ø Internal 35 mm, without head Ø Internal 60 mm Ø Internal 80 mm Ø Internal 110 mm Ø Internal 160 mm Ø Internal 210 mm Ø Internal 40 mm, split core Ø Internal 60 mm, split core Ø Internal 110 mm, split core Ø Internal 210 mm, split core TOR30 36,55 TOR15 TOR3ST TOR6 TOR8 TOR11 TOR16 TOR21 TORA40 TORA60 TORA11 TORA21 45,30 36,55 36,55 52,00 57,15 59,75 116,40 135,95 190,55 211,15 155,55 TOR30R 13,00 10mA or 400Hz use TOR3 SPLIT CORE VERSION TOR15R 13,00 TOR3R 13,00 TOR3STR 13,00 TOR6R 19,50 TOR8R 20,80 TOR11R 26,20 TOR16R 37,00 TOR21R 44,60 233,80 TORA40R TORA60R TORA11R TORA21R 53,80 55,00 53,80 95,40 INSULATION CONTROL RELAY Max measure current: ≤ 25µA Class: ±10% of selected value Dimensions: 3 DIN modules Power supply: 230V AC ±20% (other on request) Max voltage of net to control: ≤ 400V AC Measure voltage: ≤ 24V DC Selectable intervention value between 30÷300 and 300÷800 Kohm Sole power supply 22...36VAC and 19...70VDC Sole power supply 44...130VAC and 70...240VDC -P1 -P2 1RCI 128,75 154,50 154,50 MEASUREMENT TRANSDUCERS - TRUE RMS SINGLE PHASE Selectable output nominal values 1-5-10VDC and 1-5-10-20-4/20mADC ±1, ±5, ±10 VDC and ±1, ±5, ±10, ±20, 4/20 mA DC Class 0,5 Transparent sealable front cover O R 2 A 1 C 2 3 230 -24 110 -P1 -P2 = 230VAC = 24VAC = 110VAC = 22...36VAC and 19...70VDC = 44...130VAC and 70...240VDC 1COR2A... 125,00 input CODES TABLE 0 - 1 A A = current V = voltage F = frequency P = active power C = DC line power C 1COR2V... 1COR2F... 1COR2P... 1COR2C... 125,00 125,00 125,00 135,00 135,00 184,00 184,00 135,00 135,00 184,00 184,00 -1AC -5AC -5DC -10DC -60MV 135,00 135,00 184,00 184,00 135,00 135,00 184,00 184,00 . . . . . PR I EQ CE U SO ES N T 230 230 230 230 230 24 110 -P1 -P2 power supply measuring unit 2 DIN modules transducers identification Current transducers Voltage transducers Frequency transducers Single phase active power transducers DC line power transducers Sole power supply 24VAC Sole power supply 110VAC Sole power supply 22...36VAC and 19...70VDC Sole power supply 44...130VAC and 70...240VDC R Auxiliary power supply: see table Input nominal values: see table Response time ≤ 300 ms Dimensions: 2 DIN modules Resistive load: 700Ω = input 1A AC (internal CT measurement) = input 5A AC (internal CT measurement) = input 5A DC = input 10A DC = input 60mV DC (or -100MV / -150MV / -300MV) -500V = input 500V AC or DC -100V = input 100V AC or DC -110V = input 110V AC or DC -150V = input 150V AC or DC -250V = input 250V AC or DC 100R3V = input 100V: 3 AC or DC 110R3V = input 110V: 3 AC or DC -4555HZ = input 45/55 Hz -4565HZ = input 45/65 Hz -5A500V = calibration 5A 500V AC (internal CT measurement) -5A50V 42 = calibration 5A 50V DC (voltage/current measure has a common point) 05 listino GB rele diff+aut+elett prezzi ITA:listino ITA 15/11/10 16:18 Pagina 43 MEASUREMENT TRANSDUCERS The three phase active and reactive power transducers are calibrated with the following standard values: Current input 5A and the primary values are selectable by minidips Voltage input 400V On request it is possible to calibrate the transducers with the following parameters which must be indicated when ordering: Current input 1A Voltage input: 100/√3/V, 110/√3V, 100V, 110V, 230V, 440V, 500V When ordering the end scale plate value must be specified CURRENT TRANSDUCERS SELF SUPPLIED CURRENT TRANSDUCERS Response time ≤ 300 ms Dimensions: 2 DIN modules Resistive load: 300Ω for output 20mA; >10kΩ for output 10V Class 1 1CORIAA 5 20 75,00 A.C. current input 5A, Output 20mA DC input 1A, Output 20mA DC input 5A, Output 10V DC input 1A, Output 10V DC 1CORIAA 1 20 1CORIAA 5 10 1CORIAA 1 10 75,00 75,00 75,00 EXTERNAL POWER SUPPLY - AC CURRENT EXTERNAL POWER SUPPLY - DC CURRENT Standard auxiliary power supply 230VAC Selectable output nominal values 1-5-10VDC and 1-5-10-20-4/20mADC Resistive load: 700Ω Response time ≤ 300 ms Class 0,5 Standard auxiliary power supply 230VAC Selectable output nominal values 1-5-10VDC and 1-5-10-20-4/20mADC Resistive load: 700Ω Response time ≤ 300 ms Class 0,5 A.C. current Nominal input values 1A and 5A on the same device Power supply 24VAC Power supply 110VAC Sole power supply 22...36VAC and 19...70VDC Sole power supply 44...130VAC and 70...240VDC Dimensions 230 24 110 -P1 -P2 1CORIA 128,75 144,20 144,20 187,00 187,00 3DIN D.C. current Nominal input values 60 mV Power supply 24VAC Power supply 110VAC Sole power supply 22...36VAC and 19...70VDC Sole power supply 44...130VAC and 70...240VDC Dimensions 230 24 110 -P1 -P2 1CORIC 235,00 270,00 270,00 294,00 294,00 6 DIN VOLTAGE TRANSDUCERS SELF SUPPLIED VOLTAGE TRANSDUCERS Response time ≤ 300 ms Dimensions: 2 DIN modules Resistive load: 300Ω for output 20mA; >10kΩ for output 10V Class 1 1CORUAA 100 20 75,00 A.C. voltage input 100V, Output 20mA DC input 100: 3 , Output 20mA DC input 230V, Output 20mA DC input 400V, Output 20mA DC input 100V, Output 10V DC input 100: 3 , Output 10V DC input 230V, Output 10V DC input 400V, Output 10V DC 1CORUAA 100R3 20 1CORUAA 230 20 1CORUAA 400 20 1CORUAA 100 10 1CORUAA 100R3 10 1CORUAA 230 10 1CORUAA 400 10 75,00 75,00 75,00 75,00 75,00 75,00 75,00 EXTERNAL POWER SUPPLY AC VOLTAGE Standard auxiliary power supply 230VAC Selectable output nominal values 1-5-10VDC and 1-5-10-20-4/20mADC Resistive load: 700Ω Response time ≤ 300 ms Class 0,5 EXTERNAL POWER SUPPLY DC VOLTAGE Standard auxiliary power supply 230VAC Selectable output nominal values 1-5-10VDC and 1-5-10-20-4/20mADC Resistive load: 700Ω Response time ≤ 300 ms Class 0,5 A.C. voltage Nominal input values to be specified when ordering Power supply 24VAC Power supply 110VAC Sole power supply 22...36VAC and 19...70VDC Sole power supply 44...130VAC and 70...240VDC Dimensions 230 24 110 -P1 -P2 1CORUA 128,75 144,20 144,20 187,00 187,00 3DIN D.C. Voltage Nominal input values to be specified when ordering Power supply 24VAC Power supply 110VAC Sole power supply 22...36VAC and 19...70VDC Sole power supply 44...130VAC and 70...240VDC Dimensions 230 24 110 -P1 -P2 1CORUC 235,00 270,00 270,00 294,00 294,00 6 DIN DC CURRENT / VOLTAGE TRANSDUCERS - 1DIN AUXILIARY SUPPLY 24VDC Signal concentrator supports 32 single units 1CORC1. It can be connected in parallel up to 256 units for a total of (32x256) 8192 positions readable by RS485 Resistive load: 500Ω max Response time 1s Class 1 Dimensions: 1 DIN module input 15ADC, output 4/20mA input 20ADC, output 4/20mA input 15ADC, output RS485 input 20ADC, output RS485 input 600VDC, output 4/20mA input 600VDC, output RS485 input RS485, output RS485 current transducer current transducer current transducer current transducer voltage transducer voltage transducer signal concentrator 1CORIC1 125,00 1CORIC1-20 1CORIC1-RS 1CORIC1-20-RS 1CORUC1 1CORUC1-RS 1RCD1485 195,00 PRICES ON R E Q.U E S T 125,00 195,00 195,00 125,00 43 05 listino GB rele diff+aut+elett prezzi ITA:listino ITA 15/11/10 16:18 Pagina 44 POWER FACTOR TRANSDUCERS Auxiliary power supply 230VAC standard Selectable output nominal values: positive and negative ±1, ±5, ±10 VDC and ±1, ±5, ±10, ±20, 4/20 mA DC It is also possible to select the required conversion between: - proportional to the phase angle, with output 1mA DC (in degrees) for connection with an analogue measuring instrument. - proportional to cos ϕ with output ±1, ±5, ±10, ±20, ±4/20 mA and ±1, ±5, ±10 V for all other use Resistive load: 700Ω Response time ≤ 300 ms Class 0,5 Dimensions: 6 DIN modules single phase Nominal input values: voltage: 230VAC; current: 5A (1A 1CORFP10B model) three phase Nominal input values: voltage: 400VAC; current: 5A (1A 1CORFP20B model) Power supply 24VAC Power supply 110VAC Sole power supply 22...36VAC and 19...70VDC Sole power supply 44...130VAC and 70...240VDC 230 230 24 110 -P1 -P2 1CORFP10 336,80 1CORFP20 336,80 357,40 357,40 383,15 383,15 357,40 357,40 383,15 383,15 FREQUENCY TRANSDUCERS Auxiliary power supply: 230VAC standard Selectable nominal output values 1-5-10VDC and 1-5-10-20-4/20mADC Resistive load: 700Ω Response time ≤ 300 ms Measuring range 45/65Hz Class 0,5 Dimensions 3 DIN modules Nominal input values: voltage 100V ÷ 500V AC Power supply 24VAC Power supply 110VAC Sole power supply 22...36VAC and 19...70VDC Sole power supply 44...130VAC and 70...240VDC 230 24 110 -P1 -P2 1CORF 309,00 334,75 334,75 355,35 375,95 ACTIVE AND REACTIVE TRANSDUCERS POSITIVE AND NEGATIVE OUTPUTS Selectable nominal output values: ±1, ±5, ±10 VDC and ±1, ±5, ±10, ±20, 4/20 mADC Standard calibration: 100V,5A=500W (VAR) 230V,5A=1000W (VAR) 400V,5A=2000W (VAR) Input nominal values: voltage 230V (400V) - current 5A standard Auxiliary power supply 230/400VAC standard Response time ≤ 300 ms Resistive load: 700Ω Class 0,5 Active Power Dimensions: 6 DIN modules Reactive Power 1CORPA10 1CORPA20 1CORPA30 1CORPA40 1CORPA50 1CORPR10 1CORPR20 1CORPR30 1CORPR40 1CORPR50 365,65 single phase 230 355,35 355,35 365,65 3 phase, balanced load, 3 wires, without neutral 400 453,20 453,20 3 phase, unbalanced load, 3 wires, without neutral (ARON) 400 355,35 365,65 3 phase, balanced load, 4 wires, with neutral 400 520,15 530,45 3 phase, unbalanced load, 4 wires, with neutral 400 375,95 375,95 540,75 386,25 386,25 551,05 386,25 473,80 473,80 Sole power supply 22...36VAC and 19...70VDC -P1 375,95 401,70 499,55 401,70 566,50 412,00 412,00 499,55 412,00 576,80 Sole power supply 44...130VAC and 70...240VDC -P2 401,70 ACTIVE AND REACTIVE TRANSDUCERS + RS485 POSITIVE AND NEGATIVE OUTPUTS Selectable nominal output values: ±1, ±5, ±10 VDC and ±1, ±5, ±10, ±20, 4/20 mADC Standard calibration: 100V,5A=500W (VAR) 230V,5A=1000W (VAR) 400V,5A=2000W (VAR) Input nominal values: voltage 230V (400V) - current 5A standard MODBUS SLAVE RTU Protocol Auxiliary power supply 230/400VAC standard Response time ≤ 300 ms Resistive load: 700Ω Class 0,5 Dimensions: 6 DIN modules Active Power 1CORPA 10485 single phase 230 372,85 3 phase, balanced load, 3 wires, without neutral 400 3 phase, unbalanced load, 3 wires, without neutral (ARON) 400 3 phase, balanced load, 4 wires, with neutral 400 3 phase, unbalanced load, 4 wires, with neutral 400 Sole power supply 22...36VAC and 19...70VDC -P1 393,45 Sole power supply 44...130VAC and 70...240VDC -P2 419,20 44 1CORPA 20485 1CORPA 30485 1CORPA 40485 384,20 471,75 384,20 404,80 430,55 492,35 518,10 404,80 430,55 Reactive Power 1CORPA 1CORPR 1CORPR 1CORPR 1CORPR 1CORPR 50485 10485 20485 30485 40485 50485 386,25 396,55 471,75 386,25 545,90 545,90 566,50 566,50 417,15 492,35 406,85 406,85 592,25 432,60 442,90 518,10 432,60 592,25 05 listino GB rele diff+aut+elett prezzi ITA:listino ITA 15/11/10 16:18 Pagina 45 SURGE ARRESTERS DISCHARGERS WITH GAS TUBE FOR INTERNAL MOUNTING – GROUP B The protective element consists of a gas tube only. Used as galvanic separation between N-PE in a TT system. Suitable for protection against direct and indirect lightning overvoltages. Suitable for protection in zone 0A - 1. Case in policarbonate material, V0 self-extinguishing Dimensions: 1 DIN module 1RAOB 100G max working voltage Uc (AC/DC) max discharge current Imax (8/20 µs) 255V 100kA Nominal discharge current In (8/20 µs) Max discharge current Iimp (10/350 µs) 100kA 100kA 265,00 DISCHARGERS WITH VARISTOR FOR INTERNAL MOUNTING – GROUP B Dischargers with incorporated thermic protection. Suitable for installation in main distribution panels, for protection against direct or indirect lighting overvoltages. The protective element is a varistor so there are no residual currents. Suitable for protection in zones 0A - 1. Case in policarbonate material, V0 self-extinguishing. Without remote control Optical signal of fault. 1RAOB 1RAOB 1RAOB Dimensions: 2 DIN modules 150/100 max working voltage Uc (AC/DC) nominal discharge current In (8/20 µs) max discharge current Imax (8/20 µs) max discharge current Iimp (10/350 µs) max working voltage Uc (AC/DC) nominal discharge current In (8/20 µs) max discharge current Imax (8/20 µs) max discharge current Iimp (10/350 µs) max working voltage Uc (AC/DC) nominal discharge current In (8/20 µs) max discharge current Imax (8/20 µs) max discharge current Iimp (10/350 µs) max working voltage Uc (AC/DC) nominal discharge current In (8/20 µs) max discharge current Imax (8/20 µs) max discharge current Iimp (10/350 µs) 150/200V 40kA 100kA 25kA 275/350V 40kA 100kA 25kA 320/420V 40kA 100kA 25kA 440/580V 25kA 100kA 25kA 275/100 With remote control 1RAOB 440/100 320/100 180,00 1RAOB 1RAOB 1RAOB 1RAOB 150/100-T 275/100-T 320/100-T 440/100-T 190,00 180,00 190,00 180,00 190,00 180,00 190,00 DISCHARGERS WITH VARISTOR FOR INTERNAL MOUNTING – GROUP C Dischargers with incorporated thermic protection. Suitable for installation in sub distribution panels or close to the main device offering protection against indirect lighting overvoltages. The protective element is a varistor so there are no residual currents.Suitable for protection in zones 0B - 1. Case in policarbonate material, V0 self-extinguishing. Optical signal of fault. Dimensions: 1 DIN module Without remote control With remote control 1RAOC 1RAOC 1RAOC 1RAOC 1RAOC 1RAOC 1RAOC 1RAOC 1RAOC 1RAOC Interchangeable varistor 75/40 150/40 275/40 320/40 440/40 75/40-T 150/40-T 275/40-T 320/40-T 440/40-T max working voltage Uc (AC/DC) nominal discharge current In (8/20 µs) max discharge current Imax (8/20 µs) max working voltage Uc (AC/DC) nominal discharge current In (8/20 µs) max discharge current Imax (8/20 µs) max working voltage Uc (AC/DC) nominal discharge current In (8/20 µs) max discharge current Imax (8/20 µs) max working voltage Uc (AC/DC) nominal discharge current In (8/20 µs) max discharge current Imax (8/20 µs max working voltage Uc (AC/DC) nominal discharge current In (8/20 µs) max discharge current Imax (8/20 µs) 75/100V 20kA 40kA 150/200V 20kA 40kA 275/350V 20kA 40kA 320/420V 20kA 40kA 440/580V 20kA 40kA 62,00 1RAOC 75/40-F 47,00 68,00 62,00 62,00 1RAOC 275/40-F 40,00 68,00 62,00 1RAOC 320/40-F 40,00 68,00 62,00 68,00 Without remote control 1RAOC 275/10 max working voltage Uc (AC/DC) nominal discharge current In (8/20 µs) max discharge current Imax (8/20 µs) max working voltage Uc (AC/DC) nominal discharge current In (8/20 µs) max discharge current Imax (8/20 µs) max working voltage Uc (AC/DC) nominal discharge current In (8/20 µs) max discharge current Imax (8/20 µs) 1RAOC 150/40-F 43,00 68,00 275/350V 10kA 20kA 275/350V 15kA 40kA 275/350V 30kA 70kA 1RAOC 275/15 1RAOC 440/40-F 47,00 With remote control 1RAOC 275/30 46,00 1RAOC 1RAOC 1RAOC 275/10-T 275/15-T 275/30-T 1RAOC 275/10-F 31,00 56,00 55,00 1RAOC 275/15-F 40,00 65,00 95,00 Interchangeable varistor 102,00 1RAOC 275/30-F 65,00 45 05 listino GB rele diff+aut+elett prezzi ITA:listino ITA 15/11/10 16:18 Pagina 46 These devices have independent termination for L-PE and N-PE protection Without remote control 1RAOC 150/2x40 max working voltage Uc (AC/DC) nominal discharge current In (8/20 µs) max discharge current Imax (8/20 µs) max working voltage Uc (AC/DC) nominal discharge current In (8/20 µs) max discharge current Imax (8/20 µs) max working voltage Uc (AC/DC) nominal discharge current In (8/20 µs) max discharge current Imax (8/20 µs) 150/200V 15kA/pole 40kA/polo 275/350V 15kA/pole 40kA/polo 440/580V 15kA/pole 40kA/polo 1RAOC 275/2x40 With remote control 1RAOC 440/2x40 115,00 Interchangeable 1RAOC 1RAOC 1RAOC varistor 150/2x40-T 275/2x40-T 440/2x40-T 1RAOC 150/2x40-F 76,00 125,00 115,00 1RAOC 275/2x40-F 76,00 125,00 115,00 125,00 1RAOC 440/2x40-F 76,00 DISCHARGERS WITH GAS TUBE FOR INTERNAL MOUNTING – GROUP C Dischargers with incorporated thermic protection. Suitable for installation in sub distribution panels or close to the main device offering protection against indirect lighting overvoltages. Suitable for protection in zones 0B - 1. Case in policarbonate material, V0 self-extinguishing. The protective element consists of a gas tube in serie with a varistor Dimensions: 1 DIN module Without remote control 1RAOC 275/20G max working voltage Uc (AC/DC) nominal discharge current In (8/20 µs) max discharge current Imax (8/20 µs) max working voltage Uc (AC/DC) nominal discharge current In (8/20 µs) max discharge current Imax (8/20 µs) 275/350V 10kA 20kA 275/350V 15kA 30kA 1RAOC 275/30G 93,00 102,00 Interchangeable varistor 1RAOC 275/20G-F 80,00 120,00 1RAOC 275/30G-F 80,00 With remote control 1RAOC 1RAOC 275/2x10G 275/2x20G 275/350V 5kA/polo 10kA/polo 275/350V 10kA/polo 20kA/polo 1RAOC 1RAOC 275/20G-T 275/30G-T 102,00 Without remote control The protective element consists of a varistor and a gas tube mounted in series These devices have independant termination for L-PE and N-PE protection max working voltage Uc (AC/DC) nominal discharge current In (8/20 µs) max discharge current Imax (8/20 µs) max working voltage Uc (AC/DC) nominal discharge current In (8/20 µs) max discharge current Imax (8/20 µs) With remote control 80,00 1RAOC 1RAOC 275/2x10G-T 275/2x20G-T 1RAOC 275/2x10G-F 65,00 115,00 115,00 Interchangeable varistor 125,00 1RAOC 275/2x20G-F 80,00 The protective element consists of a varistor and a gas tube. Used as galvanic separation N-PE in Class II dischargers Protection against indirect lighting overvoltages. Suitable for protection in zones 0B - 1. Case in policarbonate material, V0 self-extinguishing. 1RAOC 255/40G max working voltage Uc (AC/DC) nominal discharge current In (8/20 µs) max discharge current Imax (8/20 µs) 255V 20kA 40kA 137,00 DISCHARGERS WITH VARISTOR FOR INTERNAL MOUNTING – GROUP D Dischargers with incorporated thermic protection. Suitable for installation close to the main device offering protection against indirect lighting overvoltages or overcurrents.The protective element is a varistor so there are no residual currents. Suitable for protection in zones 1-2. Case in policarbonate material, V0 self-extinguishing. Optical signal of fault. Without remote control With remote control Dimensions: 1 DIN module Interchangeable 1RAOD 1RAOD 1RAOD 1RAOD 1RAOD 1RAOD 1RAOD 1RAOD varistor 150/10 275/10 320/10 440/10 150/10-T 275/10-T 320/10-T 440/10-T max working voltage Uc (AC/DC) max discharge current Imax (8/20 µs) max working voltage Uc (AC/DC) max discharge current Imax (8/20 µs) max working voltage Uc (AC/DC) max discharge current Imax (8/20 µs max working voltage Uc (AC/DC) max discharge current Imax (8/20 µs) 150/200V 10kA 275/350V 10kA 320/420V 10kA 440/580V 10kA 50,00 60,00 46,00 56,00 46,00 Dischargers with incorporated thermic protection Suitable for installation in printed circuits against short circuits Internal fuse 16A Signal of fault max working voltage Uc: 150VC max working voltage Uc: 275VCA max working voltage Uc: 320VCA max working voltage Uc: 440VCA 46 max discharge current Imax (8/20 µs): 10kA max discharge current Imax (8/20 µs): 10kA max discharge current Imax (8/20 µs): 10kA max discharge current Imax (8/20 µs): 10kA 56,00 50,00 60,00 1RAOD 150/10-F 32,00 1RAOD 275/10-F 32,00 1RAOD 320/10-F 32,00 1RAOD 440/10-F 32,00 1RAODCS 1RAODCS 1RAODCS 1RAODCS 150/10 275/10 320/10 440/10 10,00 10,00 10,00 10,00 05 listino GB rele diff+aut+elett prezzi ITA:listino ITA 15/11/10 16:18 Pagina 47 DISCHARGERS WITH VARISTOR FOR INTERNAL MOUNTING – GROUP C Dischargers for fotovoltaic system protection against direct and indirect lighting overvoltages or overcurrents. Suitable for protection in zones 1-2 according to the IEC62305 standards FOTOVOLTAIC SYSTEM 1RAOCPV 1RAOCPV 1RAOCPV 40/100 40/550 40/1000 max working voltage Uc (AC/DC) max discharge current Imax (8/20 µs) max working voltage Uc (AC/DC) max discharge current Imax (8/20 µs) max working voltage Uc (AC/DC) max discharge current Imax (8/20 µs) Dimensions DIN modules 100 40kA 550 40kA 1000 40kA With remote control Without remote control 1RAOCPV 1RAOCPV 1RAOCPV 40/100-T 40/550-T 40/1000-T 100,00 110,00 90,00 2 100,00 135,00 3 2 2 145,00 3 2 Interchangeable varistor 1RAOCPV 40/100-F 45,00 1RAOCPV 40/550-F 41,00 1RAOCPV 40/1000-F 41,00 1 SURGE PROTECTION DEVICE FOR POWER SUPPLY On which the protective element consists of a varistor, a gas tube with thermic protection. Suitable for installation in sub distribution panels or close to the main device offering protection against indirect lighting overvoltages. Category IEC/EN/VDE Class II - Type 2/C. Case in thermoplastic material, UL 94-V0 selfextinguishing. Optical signal of fault. Protection modes L/N -PE. MOV protective element. High surge discharge rating Imax=40kA. Standards IEC-61643-1. Without remote control W NE TION RA E N GE 1RAOSAFE C150/40 max working voltage Uc (AC/DC) max discharge current Imax (8/20 µs) max working voltage Uc (AC/DC) max discharge current Imax (8/20 µs) max working voltage Uc (AC/DC) max discharge current Imax (8/20 µs) Dimensions DIN modules 150/200V 40kA 275/350V 40kA 440/580V 40kA 1RAOSAFE C275/40 With remote control 1RAOSAFE C440/40 1RAOSAFE C-T150/40 80,00 1RAOSAFE C-T275/40 80,00 150/200V 40kA per pole 275/350V 40kA per pole 440/580V 40kA per pole 83,00 1 1 1RAOSAFE C 275/80 (1+1) 1RAOSAFE C 440/80 (1+1) 141,00 1 1 With remote control 1RAOSAFE C-T 1RAOSAFE C-T 1RAOSAFE C-T 150/80 (1+1) 275/80 (1+1) 440/80 (1+1) 2 166,00 144,00 2 2 2 Without remote control 1RAOSAFE C 150/80 (2+0) max working voltage Uc (AC/DC) max discharge current Imax (8/20 µs) max working voltage Uc (AC/DC) max discharge current Imax (8/20 µs) max working voltage Uc (AC/DC) max discharge current Imax (8/20 µs) Dimensions DIN modules 150/200V 40kA per pole 275/350V 40kA per pole 440/580V 40kA per pole 1RAOSAFE C 275/80 (2+0) 1RAOSAFE C 440/80 (2+0) 160,00 1RAOSAFE C-T 1RAOSAFE C-T 1RAOSAFE C-T 150/80 (2+0) 275/80 (2+0) 440/80 (2+0) 173,00 2 173,00 165,00 2 2 2 Without remote control 1RAOSAFE C 150/120 (3+0) max working voltage Uc (AC/DC) max discharge current Imax (8/20 µs) max working voltage Uc (AC/DC) max discharge current Imax (8/20 µs) max working voltage Uc (AC/DC) max discharge current Imax (8/20 µs) Dimensions DIN modules 150/200V 40kA per pole 275/350V 40kA per pole 440/580V 40kA per pole 1RAOSAFE C 275/120 (3+0) 1RAOSAFE C 440/120 (3+0) 240,00 178,00 2 1RAOSAFE C-T 1RAOSAFE C-T 1RAOSAFE C-T 150/120 (3+0) 275/120 (3+0) 440/120 (3+0) 445,00 3 445,00 377,00 3 Interchangeable varistor 1RAOSAFEC150/80-F . 1RAOSAFEC275/80-F . 1RAOSAFEC440/80-F . 1 With remote control 240,00 3 169,00 2 With remote control 160,00 2 Interchangeable varistor 166,00 141,00 2 95,00 1 1RAOSAFEC150/40-F 70,00 1RAOSAFEC275/40-F 75,00 1RAOSAFEC440/40-F 75,00 1 93,00 Without remote control max working voltage Uc (AC/DC) max discharge current Imax (8/20 µs) max working voltage Uc (AC/DC) max discharge current Imax (8/20 µs) max working voltage Uc (AC/DC) max discharge current Imax (8/20 µs) Dimensions DIN modules Interchangeable varistor 93,00 1 1RAOSAFE C 150/80 (1+1) 1RAOSAFE C-T440/40 3 3 460,00 3 Interchangeable varistor 1RAOSAFEC150/120-F . 1RAOSAFEC275/120-F . 1RAOSAFEC440/120-F . 1 47 05 listino GB rele diff+aut+elett prezzi ITA:listino ITA 15/11/10 16:18 Pagina 48 Without remote control 1RAOSAFE C 150/160 (3+1) max working voltage Uc (AC/DC) max discharge current Imax (8/20 µs) max working voltage Uc (AC/DC) max discharge current Imax (8/20 µs) max working voltage Uc (AC/DC) max discharge current Imax (8/20 µs) Dimensions DIN modules 150/200V 40kA per pole 275/350V 40kA per pole 440/580V 40kA per pole 1RAOSAFE C 275/160 (3+1) With remote control 1RAOSAFE C 440/160 (3+1) 1RAOSAFE C-T 1RAOSAFE C-T 1RAOSAFE C-T 150/160 (3+1) 275/160 (3+1) 440/160 (3+1) 300,00 351,00 300,00 4 351,00 309,00 4 4 4 359,00 4 4 Without remote control 1RAOSAFE C 150/160 (4+0) max working voltage Uc (AC/DC) max discharge current Imax (8/20 µs) max working voltage Uc (AC/DC) max discharge current Imax (8/20 µs) max working voltage Uc (AC/DC) max discharge current Imax (8/20 µs) Dimensions DIN modules 150/200V 40kA per pole 275/350V 40kA per pole 440/580V 40kA per pole 1RAOSAFE C 275/160 (4+0) 1RAOSAFE C 440/160 (4+0) 1RAOSAFE C-T 1RAOSAFE C-T 1RAOSAFE C-T 150/160 (4+0) 275/160 (4+0) 440/160 (4+0) 383,00 320,00 383,00 330,00 4 4 4 393,00 4 4 SURGE PROTECTION DEVICE 1RAOSAFE C75PV 75/150V 40kA 300/600V 40kA 600/1200V 40kA 1000/2000V 25kA 1200/1200V 40kA Interchangeable varistor 1RAOSAFEC150/160-F . 1RAOSAFEC275/160-F . 1RAOSAFEC440/160-F . 1 FOR PHOTOVOLTAIC SYSTEM On which the protective element consists of a varistor, a gas tube with thermic protection. Suitable for installation in sub distribution panels or close to the main device offering protection against indirect lighting overvoltages. Category IEC/EN/VDE Class II - Type 2/C. Case in thermoplastic material, UL 94-V0 self-extinguishing. Optical signal of fault. Without Protection modes (+) + (-) - PE, (+) - PE / (-) - PE. MOV protective element. remote control High surge discharge rating Imax=40kA. Standards IEC-61643-1; UTE 61740-51. Backup fuses are not necessary max working voltage Uc (AC/DC) max discharge current Imax (8/20 µs) max working voltage Uc (AC/DC) max discharge current Imax (8/20 µs) max working voltage Uc (AC/DC) max discharge current Imax (8/20 µs) max working voltage Uc (AC/DC) max discharge current Imax (8/20 µs) max working voltage Uc (AC/DC) max discharge current Imax (8/20 µs) Dimensions DIN modules 1RAOSAFEC150/160-F . 1RAOSAFEC275/160-F . 1RAOSAFEC440/160-F . 1 With remote control 320,00 4 Interchangeable varistor 1RAOSAFE C300PV 1RAOSAFE C600PV 1RAOSAFE C1000PV 1RAOSAFE C1200PV Interchangeable varistor 270,00 3 1RAOSAFEC75PV-F 77,00 1RAOSAFEC300PV-F 80,00 1RAOSAFEC600PV-F 80,00 1RAOSAFEC1000PV-F 92,00 1RAOSAFEC1200PV-F 95,00 1 95,00 165,00 185,00 195,00 2 2 2 2 W NE TION A ER N GE With remote control 1RAOSAFE C-T75PV max working voltage Uc (AC/DC) max discharge current Imax (8/20 µs) max working voltage Uc (AC/DC) max discharge current Imax (8/20 µs) max working voltage Uc (AC/DC) max discharge current Imax (8/20 µs) max working voltage Uc (AC/DC) max discharge current Imax (8/20 µs) max working voltage Uc (AC/DC) max discharge current Imax (8/20 µs) Dimensions DIN modules 48 75/150V 40kA 300/600V 40kA 600/1200V 40kA 1000/2000V 25kA 1200/1200V 40kA 1RAOSAFE C-T300PV 1RAOSAFE C-T600PV 1RAOSAFE 1RAOSAFE C-T1000PV C-T1200PV 110,00 180,00 200,00 210,00 2 2 2 2 285,00 3 Interchangeable varistor 1RAOSAFEC75PV-F 77,00 1RAOSAFEC300PV-F 80,00 1RAOSAFEC600PV-F 80,00 1RAOSAFEC1000PV-F 92,00 1RAOSAFEC1200PV-F 95,00 1 05 listino GB rele diff+aut+elett prezzi ITA:listino ITA 15/11/10 16:18 Pagina 49 EQUIPMENT FOR INDUSTRIAL AUTOMATION 8 ALARM CHANNELS SET Control device and signalling alarms device in accordance to the functional standard ”ISA M” (ex ISA 2C) that represent the most diffused device in industrial and marine fields.It is manufactured in a DIN 96x96 flush mounting box and contains eight signalling correspondent to as much alarm conditions, a relay positive safety cumulative alarms), a silenceable electric siren relay and an RS485 interface (10 devices can be connected simultaneously). Alarms legend (changeable thin cards) permits to the user to describe the typology of alarm. Front panel permits the access to the thin cards and to the settable input mini switches (easy safety access without opening the electrical board). Power supply 230VAC Sole power supply 22...36VAC and 19...70VDC Sole power supply 44...130VAC and 70...240VDC 230 -P1 -P2 2RISA96 360,50 415,50 415,50 1RSQI 1RSQE CONTROL AND SEQUENCE PHASE RELAYS Power supply: 400V (selfpowered) ~50/60Hz Appliable load: three-phase voltage Output relay NO-C-NC 1RSQ To control the correct sequence and presence of the phases in a three phase system and the control of the voltage values within the limits (70-100%) To control the correct sequence and presence of the phases in a three phase system, presence of the neutral and the control of the voltage values within the limits (70-100%) To control the correct sequence, presence and asimmetry of the three phases To control the correct sequence and presence of the three phases Dimensions 1RSQN 92,70 108,15 77,25 3DIN 3DIN 41,20 2DIN 2DIN MIN / MAX SINGLE-PHASE A.C. CURRENT RELAYS Power supply standard: 230V 50Hz ±10% (galvanically insulated) Output relay: 16A 250V ~ resistive load Hysteresis: 1 ÷ 45% adjustable potentiometer on front Delay time: 1 ÷ 30 sec adjustable potentiometer on front Calibration: 30 ÷ 100% adjustable potentiometer on front Dimensions: 3 DIN modules Minimum current relay - N° 3 inputs for 3 different ranges between 2A, 5A and 10A Maximum current relay - N° 3 inputs for 3 different ranges between 2A, 5A and 10A Minimum current relay - N° 3 inputs for 4 different ranges between 1mA, 10mA and 20mA (4÷20mA) Maximum current relay - N° 3 inputs for 4 different ranges between 1mA, 10mA and 20mA (4÷20mA) Sole power supply 22...36VAC and 19...70VDC Sole power supply 44...130VAC and 70...240VDC AC AC DC DC 230 230 230 230 -P1 -P2 1RSLI 123,60 1RSHI 1RSLIC 1RSHIC 123,60 97,85 182,00 182,00 182,00 182,00 156,00 156,00 97,85 156,00 156,00 1RSHV 1RSLVC 1RSHVC MIN / MAX SINGLE-PHASE A.C. VOLTAGE RELAYS The input voltage signal must be specified when ordering Power supply standard: 230V 50Hz ±10% (galvanically insulated) Output relay: 16A 250V ~ resistive load Hysteresis: 1 ÷ 45% adjustable potentiometer on front Delay time: 1 ÷ 30 sec adjustable potentiometer on front Calibration: 30 ÷ 100% adjustable potentiometer on front Dimensions: 3 DIN modules Minimum voltage relay Maximum voltage relay Minimum voltage relay Maximum voltage relay Sole power supply 22...36VAC and 19...70VDC Sole power supply 44...130VAC and 70...240VDC AC AC DC DC 230 230 230 230 -P1 -P2 1RSLV 97,85 97,85 97,85 156,00 156,00 156,00 156,00 156,00 156,00 97,85 156,00 156,00 AMMETERS - DOUBLE THRESHOLD (MIN / MAX) Power supply standard: 230V 50Hz ±10% (galvanically insulated) Measure of current in TRUE RMS from CT.../5A 2 selectable current threshold with only one ON output relay Thresholds indication Selectable optical pre.alarm Dimensions: 2 DIN modules Power supply standard: 230V 50Hz ±10% (galvanically insulated) Sole power supply 22...36VAC and 19...70VDC Sole power supply 44...130VAC and 70...240VDC 230 -P1 -P2 1RSDI 92,70 151,00 151,00 49 05 listino GB rele diff+aut+elett prezzi ITA:listino ITA 15/11/10 16:18 Pagina 50 STABILISED SUPPLIES Power supply: 230V ± 10%, 50/60 Hz Galvanic separation between input and output Protected against short-circuits, the polarity inversions and overtemperature 1RAL12 Stabilized output as supplier 12 VDC ± 2% - 0,5 A Stabilized output as battery charger 13 VDC - 1 A Stabilized output as supplier 24 VDC ± 2% - 0,5 A Stabilized output as battery charger 26 VDC - 0,5 A Power 55VA; Output voltage 14 VAC (2A) Stabilized output 13 VDC - 2 A; Relay NO (0,5 A/40VDC) Power 55VA; Output voltage 28 VAC (2A) Stabilized output 26 VDC - 2 A; Relay NO (0,5 A/40VDC) Output voltage 2x13,2VDC - Output current 2x2ADC Dimensions 1RAL24 1RAL122 1RAL242 1RAL800 57,70 57,70 123,60 123,60 3DIN 3DIN 8DIN 80,00 6DIN 8DIN AUTOMATIC BATTERY CHARGERS Power supply: 230-400VCA +/- 10% 50/60 Hz (230V ± 10% for model RAL2E12) Galvanic separation between input and output Protected against short-circuits, the polarity inversions and overtemperature 2A, 12VDC 5A, 12VDC 5A, 24VDC 12A, 24VDC power 20VA power 80VA power 80VA power 750VA RAL2E12 100,00 RAL5SE12 RAL5SE24 RAL12PRO24 220,00 220,00 600,00 EMERGENCY SUPPLY Automatic battery charging, DIN rail mounting. Small size of battery, dimensions 100x45x120 mm Output supply during black out (L) with automatic shut down for preserve the battery integrity Galvanic isolation from auxiliary supply (230vac) tipical for electrical safety device (insulation 4 kv between 230VAC and 12VDC) Charge 24 hour before that be used RAL12E 100,00 Auxiliary supply 230VAC live EQUIPMENT FOR CIVIL AUTOMATION ALARMS MODULAR VERSION Power supply: 230 VAC Burden 5mA at 230V Acoustic power 84dB at 1 meter Dimensions: 2 DIN modules 1RSA 34,00 Multi-use employment EMERGENCY STATIC LAMP MODULAR VERSION Static illuminant element with unlimited duration (Absence of batteries, ecologic device) with high luminosity intensity (8000 mcd peak). The unlimited duration produces an ideal device for the use in the cases of the certainty of work when the auxiliary power supply is fundamental. Useful autonomy illumination: 2 h Recharge time: 2 h Dimensions: 2 DIN modules Power supply: 230 VAC 50/60 Hz 50 1RLE 56,65 05 listino GB rele diff+aut+elett prezzi ITA:listino ITA 15/11/10 16:18 Pagina 51 ANALOGUE TIME SWITCHES MODULAR VERSION Switching contact (silver/cadmio) one change over, 16A - 250V (2A inductive load) Accuracy: time: ± 25 sec/month; operating: ± 3 min Power supply: from 180 to 240V ± 10% Manual operating switch: OFF - ON - AUTOMATIC Quartz movement Dimensions: 3 DIN modules 1ROM1RE Daily time switch, without back-up time Minimum setting interval: 15 min Daily time switch, with back-up time (150 hours) Minimum setting interval: 15 min Weekly time switch, with back-up time (150 hours) Minimum setting interval: 2 h, sealable front 1ROM1R 1ROM7R Power supply: from 220 to 240V ± 10% 50/60 Hz Accuracy: time: ± 3 sec/day Manual operating switch 2 positions: AUTOMATIC - PERMANENT Switching contact (silver/cadmio) one change over, 16A - 250V (4A inductive load) Sealable front Dimensions: 1 DIN module 1ROM1DR Daily time switch Quartz movement Minimum setting interval: 15 min back-up time 100 hours 51,00 72,10 39,15 99,00 DIGITAL TIME SWITCHES MODULAR VERSION Power supply: 230V ± 10% - 50/60 Hz Manual operating switch: Manual ON - Auto - Manual OFF Sealable front Dimensions: 2 DIN modules Accuracy time: ± 1 min/month Contact: 1A=10A/250V, 16A/30VDC 1C=10A/250V, 12A/30VDC Summer/Winter function 1ROM2ER 77,25 Daily time switch - Minimum settable cycle: 1 min - Backup time 300 hours ASTRONOMICAL TIME SWITCHES MODULAR VERSION The device is an electronic time-switch to manage electrical applicances from sunset to dawn, according to the geographic area set. It performs type 1B actions and is designed for household and similar purposes in enviroments with normal pollution degree and overvoltage category III. Reference standards: Compliance with Community Directives 2006/95/CEE (Low Voltage - LVD ) and 2004/108/CE ( Electromagnetic compatibility E.M.C.)is declared with reference to the following standards: CEI EN60730-2-7 E.M.C. : CEI EN 61000-6-1 / CEI EN 61000-6-3 Power supply: 230V (-15%....+10%) - 50/60 Hz 1RLUX 145,00 One output relay Two output relays 1RLUX2 175,00 CREPUSCULAR SWITCH MODULAR VERSION The modular crepuscolar swith is an electronic device to manage electrical applicances from sunset to dawn. It performs type 1B actions and is designed for household and similar purposes in enviroments with normal pollution degree and overvoltage category III. Reference standards: Compliance with Community Directives 2006/95/CEE (Low Voltage - LVD ) and 2004/108/CE ( Electromagnetic compatibility E.M.C.)is declared with reference to the following standards: CEI EN606692-1 (97) E.M.C. : CEI EN55014 (94 / CEI EN 55104 (96) Power supply: 230V (-15%....+10%) - 50/60 Hz 1RLUX1 85,00 With external probe MULTIVOLTAGE RELAYS MODULAR VERSION Wide voltage coil range for every application in VDC or VAC, range from 12....400VDC and 12....270VAC for electrical maintenance or new installation not depending by the voltage supply and electrical photovoiltaic applications. Low consumption 0.4W for pick up time; 0.2W all working time 1RMR1 . ON ES T IC UES R P EQ R One output relay Two output relays 1RMR2 . IMPULSE RELAYS 2 sequences Elettromechanical 1 contact, 12 VAC Elettromechanical 1 contact, 24 VAC Elettromechanical 1 contact, 230 VAC Elettromechanical 2 contacts, 12 VAC Elettromechanical 2 contacts, 24 VAC Elettromechanical 2 contacts, 230 VAC Elettromechanical 2 contacts, 12 VAC Elettromechanical 2 contacts, 24 VAC Elettromechanical 2 contacts, 230 VAC Electronic, 16A, 230VAC, 1DIN RRI012-12 7,50 RRI012-24 RRI012-230 RRI022-12 RRI022-24 RRI022-230 RRI032-12 RRI032-24 RRI032-230 1REP 7,50 7,50 9,00 9,00 9,00 9,00 9,00 9,00 33,00 51 05 listino GB rele diff+aut+elett prezzi ITA:listino ITA 15/11/10 16:18 Pagina 52 STAIRS LIGHT ELECTRONIC RELAY MODULAR VERSION Power supply: 230 VAC Burden <2W Dimensions: 1 DIN modules Nominal current 16A 1RET 29,85 With end-time notice Without end-time notice 1RET-A 29,85 MODULAR CURRENT SOCKET MODULAR VERSION For connection of non modular devices and tools into switcboards and panels Nominal Voltage Un 250V Nominal Current In 16A Frequency 50/60 Hz 1RPIT 9,00 Bivalent italian / schuko SAFETY BELL TRANSFORMERS WITH PTC AND SWITCH Resistant to the short-circuit series Standards: EN61558-1-2-8 Nominal frequency 50Hz Thermic and short-circuit protection by PTC Dimensions: 2 DIN modules Power supply 230VAC IMQ on type 1RTC88M On/Off switch INTERMITTENT USE 1RTC88M 1RTC812M 1RTC824M 25,75 secondary voltage 8V - non continuous power on the secondary 8V=8VA secondary voltage 12V - non continuous power on the secondary 12V=8VA secondary voltage 24V - non continuous power on the secondary 24V=8VA 25,75 25,75 SAFETY BELL TRANSFORMERS WITH PTC IMQ on types 1RTC1512 / 1RTC1524, 1RTC3012 /1RTC3024, 1RTC4012 /1RTC4024 Resistant to the short-circuit series Thermic and short-circuit protection by PTC Standards: EN61558-1-2-8 Power supply 230VAC Nominal frequency 50Hz INTERMITTENT USE 1RTC1512 1RTC1524 1RTC168 1RTC1612 1RTC1624 1RTC3012 1RTC3024 1RTC4012 1RTC4024 secondary voltages 4 - 8 and 12V non continuous power on the secondary 4V=5VA - 8V=10VA - 12V=15VA secondary voltages 12 -12 and 24V non continuous power on the secondary 12V=7,5VA - 12V=7,5VA -24V=15VA secondary voltages 8V potenza discontinua sul secondary 8V=16VA secondary voltages 12V non continuous power on the secondary 12V=16VA secondary voltages 24V non continuous power on the secondary 24V=16VA secondary voltages 4 - 8 and 12V non continuous power on the secondary 4V=10VA - 8V=20VA - 12V=30VA secondary voltages 12 -12 and 24V non continuous power on the secondary 12V=15VA - 12V=15VA - 24V=30VA secondary voltages 4 - 8 and 12V non continuous power on the secondary 4V=13VA - 8V=27VA - 12V=40VA secondary voltages 12 -12 and 24V non continuous power on the secondary 12V=20VA - 12V=20VA - 24V=40VA Dimensions DIN modules 20,60 20,60 19,30 19,30 19,30 26,50 26,50 29,60 2 2 2 2 2 3 SAFETY BELL TRANSFORMERS 3 3 29,60 3 STANDARD SERIES Standards: EN61558-1-2-8 Power supply 230VAC Nominal frequency 50Hz IMQ on all range INTERMITTENT USE secondary voltages 4 - 8 and 12V non continuous power on the secondary secondary voltages 12 -12 and 24V non continuous power on the secondary secondary voltages 4 - 8 and 12V non continuous power on the secondary secondary voltages 12 -12 and 24V non continuous power on the secondary secondary voltages 4 - 8 and 12V non continuous power on the secondary secondary voltages 12 -12 and 24V non continuous power on the secondary secondary voltages 4 - 8 and 12V non continuous power on the secondary secondary voltages 12 -12 and 24V non continuous power on the secondary Dimensions DIN modules 52 4V=3,3VA - 8V=6,6VA - 12V=10VA 1RT1012 1RT1024 1RT1512 1RT1524 1RT3012 1RT3024 1RT4012 1RT4024 14,60 14,60 12V=5VA - 12V=5VA - 24V=10VA 17,00 4V=5VA - 8V=10VA - 12V=15VA 17,00 12V=7,5VA - 12V=7,5VA - 24V=15VA 22,95 4V=10VA - 8V=20VA - 12V=30VA 22,95 12V=15VA - 12V=15VA - 24V=30VA 27,00 4V=13VA - 8V=27VA - 12V=40VA 12V=20VA - 12V=20VA - 24V=40VA 2 2 2 2 3 3 3 27,00 3 05 listino GB rele diff+aut+elett prezzi ITA:listino ITA 15/11/10 16:18 Pagina 53 SAFETY BELL TRANSFORMERS WITH PTC Resistant to the short-circuit series Thermic and short-circuit protection by PTC Power supply 230VAC Standards: EN61558-1-2-8 Nominal frequency 50Hz IMQ on all range CONTINUOUS USE secondary voltages 12 and 24V - continuous power on the secondary 12V=15VA - 24V=15VA secondary voltages 12 and 24V - continuous power on the secondary 12V=25VA - 24V=25VA secondary voltages 12 and 24V - continuous power on the secondary 12V=40VA - 24V=40VA secondary voltages 12 and 24V - continuous power on the secondary 12V=63VA - 24V=63VA Dimensions DIN modules BELLS 1RSTC15 26,35 1RSTC25 1RSTC40 1RSTC63 32,45 42,25 3 3 54,60 6 4 3 TONES ELECTRONIC BELL Intermittent use Acoustic power 84 dB at 1 meter Dimensions: 1 DIN module power supply 230VAC power supply 12VAC Intermittent use Acoustic power 100 dB at 1 meter Dimensions: 2 DIN modules burden 10VA burden 5VA 1RSU230 3,00 1RSU12 power supply 230VAC burden 5VA 1RSUE 39,15 1RTRZ 1RTRS 3,00 BUZZERS Intermittent use Acoustic power 84 dB at 1 meter Dimensions: 1 DIN module power supply 230VAC power supply 12VAC burden 10VA burden 5VA BELLS AND BUZZERS WITH TRANSFORMERS Bell acoustic power 80 dB at 1 meter Magnetization primary current 30mA max IMQ on all range Buzzer acoustic power 70 dB at 1 meter Dimensions: 2 DIN modules secondary voltage 24VAC - power on secondary 24V 6,1VA secondary voltage 24VAC - power on secondary 24V 6,1VA secondary voltage 24VAC - power on secondary 24V 3,8VA + 3,8VA 1RTSU 27,30 27,30 32,45 EQUIPMENTS FOR GENERATING SET OVER SPEED CONTROL RELAYS Power supply: 12VDC and 24VDC present on the same relay For petrol and diesel engines, input by pick-up Two output relais Dimensions: 3 DIN modules 1RSV 1224 103,00 Speed limit adjustable from 0 to 6000 Hz MANUAL PROTECTION 3 alarm inputs with motor stopping: oil pressure, water temperature, overspeed 2 alarm inputs without motor stopping: battery charge, fuel level Auxiliary power supply 12/24 VDC Overspeed by load Overspeed by electrical generator frequency Semi-automatic model 2RPM72 206,00 2RPM72F 2RPM72SA 231,75 242,05 53 05 listino GB rele diff+aut+elett prezzi ITA:listino ITA 15/11/10 16:18 Pagina 54 PROGRAMMABLE RECORDERS PROGRAMMABLE RECORDERS WITH DIGITAL DISPLAY Roll or Z-fold chart Pre-configured, Universal, Isolated inputs PC configuration Annotation (optional) Chart illumination 236 mm overall depht behind panel Front access to pen zero/span adjust Up to 8 relay outputs Ready for immediate use 6REG2C/1CH 4841,00 1 3-Colour digital display pens number 6REG2C/2CH 6180,00 2 6REG2C/3CH 6REG2C/4CH 7210,00 8343,00 3 4 PROGRAMMABLE RECORDERS WITH DIGITAL DISPLAY AND CONFIGURATION BOARD Roll or Z-fold chart Front panel or PC configuration Universal isolated inputs Chart illumination Maths, timers, counters and totalisers Memory card (PCMCIA) reader MODBUS® communications 236 mm total depht behind panel Up to 16 relay outputs Up to 4 analogue outputs 16 contact inputs 6REG3C/1CH 6180,00 1 4-Colour digital display with analogue bargraphs pens number 6REG3C/2CH 7055,50 2 6REG3C/3CH 8755,00 3 6REG3C/4CH 10094,00 4 PROGRAMMABLE RECORDERS WITH DIGITAL DISPLAY - 6 MULTIPOINT PENS Roll or Z-fold chart 3-Colour digital display Pre-configured, Universal, Isolated inputs PC configuration Annotation 236 mm overall depht behind panel Front access to pen zero/span adjust Up to 8 relay outputs Ready for immediate use 6REG2T/6CH 6798,00 6 pens PROGRAMMABLE RECORDERS WITH DIGITAL DISPLAY AND CONFIGURATION BOARD - 6 MULTIPOINT PENS 4-Colour digital display with analogue bargraphs Roll or Z-fold chart Front panel or PC configuration Universal isolated inputs Chart illumination Maths, timers, counters and totalisers Memory card (PCMCIA) reader MODBUS® communications 236 mm overall depht behind panel Up to 16 relay outputs Up to 4 analogue outputs 16 contact inputs 6REG3T/6CH 8755,00 6 pens ACCESSORIES Fold format chart (50 standard divisions) Roll format chart (50 standard divisions) Roll chart drawer (32 meter) BLUE pen (chanel 1) RED pen (chanel 2) GREEN pen (chanel 3) VIOLET pen (chanel 4) BLACK pen (for Annotator) 6 colours cartridge for 6REG...T Annotator for date and hour writting in European format Annotator for date and hour writting in American format PC configuration package (disk + connection cable) 54 AZFOLD 41,20 AROL ACASS APEN1 APEN2 APEN3 APEN4 APENA ACAR6 36,05 288,40 44,30 44,30 44,30 44,30 49,45 206,00 AFE 1091,80 AFA CONFED 1091,80 839,45 06 listino GB variat prezzi ITA:listino ITA 15/11/10 16:18 Pagina 55 ADJUSTABLE TRANSFORMERS The standard versions are supplied by 230V +10% input voltages. This voltage must never be higher than 6% of the nominal value to avoid possible increases of the temperature in the winding over the admitted limit. The secondary circuit conforms to standards VDE 0552/5.69, must be protected against the short circuits by a fuse or thermic protection. The primary circuit must be protected by a time delayed fuse with proper range. The standard working frequence is 50Hz. Models with frequence at 400Hz can be available on request; it should be understood however that the losses of the core caused by the magnetic hysteresys increases with the increase of the frequence Test voltage is 2,5kV at 50Hz from the metallic parts and the points under voltage Protection degree: class I SINGLE-PHASE OPEN EXECUTION Input voltage 48V - Adjustment range 0...48V Input voltage 230V - Adjustment range 0...230V Input voltage 230V - Adjustment range 0...250V Input voltage 230V - Adjustment range 0...250V Input voltage 230V - Adjustment range 0...250V Input voltage 230V - Adjustment range 0...260V Input voltage 230V - Adjustment range 0...260V Input voltage 230V - Adjustment range 0...230V Power VA / Model 5A 0,8A 1,2A 2,5A 5A 8A 13A 1A Input voltage 230V - Adjustment range 0...230V Input voltage 230V - Adjustment range 0...230V Input voltage 230V - Adjustment range 0...230V Input voltage 230V - Adjustment range 0...230V Input voltage 230V - Adjustment range 0...230V Input voltage 230V - Adjustment range 0...230V Input voltage 230V - Adjustment range 0...230V Input voltage 230V - Adjustment range 0...230V Power VA / Model 1,25A 1,6A 2A 2,5A 3A 4A 4,5A 6A Input voltage 230V - Adjustment range 0...230V Input voltage 230V - Adjustment range 0...230V Input voltage 230V - Adjustment range 0...230V Input voltage 230V - Adjustment range 0...230V Input voltage 230V - Adjustment range 0...230V Input voltage 230V - Adjustment range 0...230V Input voltage 230V - Adjustment range 0...260V Input voltage 230V - Adjustment range 0...260V Power VA / Model 8A 10A 12A 18A 23A 32A 0,8A 1A Input voltage 230V - Adjustment range 0...260V Input voltage 230V - Adjustment range 0...260V Input voltage 230V - Adjustment range 0...260V Input voltage 230V - Adjustment range 0...260V Input voltage 230V - Adjustment range 0...260V Input voltage 230V - Adjustment range 0...260V Input voltage 230V - Adjustment range 0...260V Input voltage 230V - Adjustment range 0...260V Power VA / Model 1,4A 1,6A 2A 2,5A 3A 3,5A 4,5A 6,3A Input voltage 230V - Adjustment range 0...260V Input voltage 230V - Adjustment range 0...260V Input voltage 230V - Adjustment range 0...260V Input voltage 230V - Adjustment range 0...260V Input voltage 230V - Adjustment range 0...260V Power VA / Model 8A 10A 15A 20A 30A 7HSG0011/48 7HSG0011/230 211,15 211,15 7HSG0022 7HSG0052 7HSG0102 7HSG0202 7HSG0302 7HSG230/1 242,05 262,65 298,70 381,10 597,40 240 180 300 620 1250 2080 3380 221,45 230 / M15 7HSG230/1,25 226,60 7HSG230/1,6 7HSG230/2 7HSG230/2,5 7HSG230/3 7HSG230/4 7HSG230/4,5 7HSG230/6 257,50 262,65 267,80 293,55 298,70 375,95 287 / M15 368 / M30 460 / M30 575 / M30 690 / M50 920 / M50 1035 / M100 381,10 1380 / M100 7HSG230/8 453,20 7HSG230/10 7HSG230/12 7HSG230/18 7HSG230/23 7HSG230/32 7HSG260/0,8 7HSG260/1 504,70 669,50 993,95 1318,40 1843,70 226,60 1840 / M200 2300 / M200 2760 / M250 4140 / M300 5290 / M400 7360 / M500 208 / M15 236,90 230 / M15 7HSG260/1,4 257,50 7HSG260/1,6 7HSG260/2 7HSG260/2,5 7HSG260/3 7HSG260/3,5 7HSG260/4,5 7HSG260/6,3 262,65 267,80 298,70 309,00 370,80 381,10 364 / M30 416 / M30 520 / M30 650 / M50 780 / M50 7HSG260/8 484,10 7HSG260/10 7HSG260/15 7HSG260/20 7HSG260/30 910 / M100 1170 / M100 453,20 1638 / M100 597,40 988,80 1318,40 2080 / M200 2600 / M250 3900 / M300 5200 / M400 SINGLE-PHASE 1843,70 7800 / M500 METALLIC CASE EXECUTION Input voltage 230V Adjustment range 0...250V Adjustment range 0...260V Adjustment range 0...260V Adjustment range 0...260V Adjustment range 0...260V Adjustment range 0...260V Adjustment range 0...260V Adjustment range 0...260V Adjustment range 0...260V Power VA / Model 5A 7A 13A 4,5A 8A 10A 15A 20A 30A 7HSN0103 515,00 7HSN0203 7HSN0303 7HSN260/4,5 7HSN260/8 7HSN260/10 7HSN260/15 7HSN260/20 7HSN260/30 587,10 798,25 643,75 772,50 1030,00 1606,80 2039,40 1250 1820 3380 1170 / M100 2080 / M200 2600 / M250 3900 / M300 5200 / M400 2765,55 7800 / M500 55 06 listino GB variat prezzi ITA:listino ITA 15/11/10 16:18 Pagina 56 THREE-PHASE OPEN EXECUTION Input voltage 400V - Adjustment range 0...430V Input voltage 400V - Adjustment range 0...430V Input voltage 400V - Adjustment range 0...450V Input voltage 400V - Adjustment range 0...450V Input voltage 400V - Adjustment range 0...400V Input voltage 400V - Adjustment range 0...400V Input voltage 400V - Adjustment range 0...400V Input voltage 400V - Adjustment range 0...400V Power VA / Model 2,5A 5A 8A 13A 1A 1,25A 1,6A 2A Input voltage 400V - Adjustment range 0...400V Input voltage 400V - Adjustment range 0...400V Input voltage 400V - Adjustment range 0...400V Input voltage 400V - Adjustment range 0...400V Input voltage 400V - Adjustment range 0...400V Input voltage 400V - Adjustment range 0...400V Input voltage 400V - Adjustment range 0...400V Input voltage 400V - Adjustment range 0...400V Power VA / Model 2,5A 3A 4A 4,5A 6A 8A 10A 12A Input voltage 400V - Adjustment range 0...400V Input voltage 400V - Adjustment range 0...400V Input voltage 400V - Adjustment range 0...400V Input voltage 400V - Adjustment range 0...450V Input voltage 400V - Adjustment range 0...450V Input voltage 400V - Adjustment range 0...450V Input voltage 400V - Adjustment range 0...450V Input voltage 400V - Adjustment range 0...450V Power VA Model 18A 23A 32A 0,8A 1A 1,4A 1,6A 2A Input voltage 400V - Adjustment range 0...450V Input voltage 400V - Adjustment range 0...450V Input voltage 400V - Adjustment range 0...450V Input voltage 400V - Adjustment range 0...450V Input voltage 400V - Adjustment range 0...450V Input voltage 400V - Adjustment range 0...450V Input voltage 400V - Adjustment range 0...450V Input voltage 400V - Adjustment range 0...450V Power VA Model 2,5A 3A 3,5A 4,5A 6,3A 8A 10A 15A Input voltage 400V - Adjustment range 0...450V Input voltage 400V - Adjustment range 0...450V Power VA Model 20A 30A 7HTO0152 1014,55 7HTO0302 7HTO0702 7HTO0902 56 7HTG400/1,25 7HTG400/1,6 7HTG400/2 1133,00 1318,40 1998,20 844,60 860,05 937,30 1900 3700 6240 10140 690 / 3-M15 861 / 3-M15 1104 / 3-M30 957,90 1380 / 3-M30 7HTG400/2,5 963,05 7HTG400/3 7HTG400/4 7HTG400/4,5 7HTG400/6 7HTG400/8 7HTG400/10 7HTG400/12 1030,00 1091,80 1297,80 1318,40 1565,60 1725,25 1725 / 3-M30 2070 / 3-M50 2214,50 2760 / 3-M50 3105 / 3-M100 4140 / 3-M100 5520 / 3-M200 6900 / 3-M200 8280 / 3-M250 7HTG400/18 3223,90 7HTG400/23 7HTG400/32 7HTG450/0,8 7HTG450/1 7HTG450/1,4 7HTG450/1,6 7HTG450/2 4326,00 6607,45 860,05 865,20 957,90 957,90 12420 3-M300 15870 3-M400 22080 3-M500 620 3-M15 780 3-M15 1092 3-M30 1248 3-M30 963,05 1560 3-M30 7HTG450/2,5 1081,50 7HTG450/3 7HTG450/3,5 7HTG450/4,5 7HTG450/6,3 7HTG450/8 7HTG450/10 7HTG450/15 1091,50 1297,80 1318,40 1565,60 1648,00 2008,50 1950 3-M50 2340 3-M50 7HTG450/20 4326,00 7HTG450/30 15600 3-M400 2730 3-M100 3510 3-M100 4914 3-M200 6240 3-M200 7800 3-M250 3223,90 11700 3-M300 6607,45 23400 3-M500 THREE-PHASE Input voltage 400V - Adjustment range 0...450V Input voltage 400V - Adjustment range 0...450V Input voltage 400V - Adjustment range 0...450V Input voltage 400V - Adjustment range 0...450V Input voltage 400V - Adjustment range 0...450V Input voltage 400V - Adjustment range 0...450V Input voltage 400V - Adjustment range 0...450V Power VA Model 7HTG400/1 METALLIC CASE EXECUTION 7A 13A 8A 10A 15A 20A 30A 7HTN0703 1276,00 7HTN0903 7HTN450/8 7HTN450/10 7HTN450/15 7HTN450/20 7HTN450/30 1906,00 1733,00 2000,00 2940,00 3728,00 5460 10140 6240 3-M200 7800 3-M250 11700 3-M300 15600 3-M400 5455,00 23400 3-M500 06 listino GB variat prezzi ITA:listino ITA 15/11/10 16:18 Pagina 57 MOTORISATION Adjustable transformers in motorised execution Input voltage 230V Adjustment range 0...230V Adjustment range 0...230V Adjustment range 0...230V Adjustment range 0...260V Adjustment range 0...260V Adjustment range 0...260V Power VA / Model 18A 23A 32A 15A 20A 30A 7HSM230/18 1946,70 7HSM230/23 7HSM230/32 7HSM260/15 7HSM260/20 7HSM260/30 2286,60 2863,40 1946,70 2286,60 4140 / M300 5290 / M400 7360 / M500 3900 / M300 5200 / M400 2863,40 7800 / M500 7HMAM50 731,30 7HMAM100 7HMAM200 7HMAM250 Motorisation for single-phase adjustable transformers The auxiliary power supply of the motor is 230VAC The travel time of the brushes to make one complete round is about 23 seconds Other transformers can be motorised using the correct motor choosing it between the following models Available for types M50 Available for types M100 Available for types M200 Available for types M250 762,20 762,20 762,20 Motorisation for three-phase adjustable transformers The auxiliary power supply of the motor is 230VAC The travel time of the brushes to make one complete round is about 23 seconds Other transformers can be motorised using the correct motor choosing it between the following models 7HMA3/M50 890,95 Available for types 3-M50 Available for types 3-M100 Available for types 3-M200 Available for types 3-M250 Available for types 3-M300 Available for types 3-M400 Available for types 3-M500 7HMA3/M100 7HMA3/M200 7HMA3/M250 7HMA3/M300 7HMA3/M400 7HMA3/M500 906,40 906,40 906,40 937,30 952,75 952,75 ACCESSORIES AMAN458 13,40 Knob for open adjustable transformer HSG0022 with shaft Ø 8mm Knob for all other open adjustable transformers model HSG with shaft Ø 8mm and three-phase open adjustable transformers model HTO Knob for open single-phase and three-phase adjustable transformer from model M15 to M50 with shaft Ø 6mm Knob for open single-phase and three-phase adjustable transformer from model M100 to M500 with shaft Ø 10mm Graduated scale plate for adjustable transformer HSG0022, M15 and M30 Graduated scale plate for all other adjustable transformer AMAN808 AMAN456 AMAN810 ASG1 ASG2 14,42 13,40 15,45 7,30 7,30 VARIABLE RESISTORS Precision class ±10% Insulation resistance: > 5MΩ Earthing resistance: < 0,1Ω Allowed voltage at terminals: max 800V Insulation voltage against casing: > 1,5 kV Insulation: Class B Protection degree: IP20 Standards: DIN 41480-SE6 / DIN 40050 / VDE 0110 / 750V rms SINGLE-PHASE Power 160W Resistive value Resistive value Resistive value Resistive value Resistive value Resistive value Resistive value Resistive value 1Ω 3,3 Ω 10 Ω 33 Ω 100 Ω 330 Ω 1000 Ω 3300 Ω 7PRN162 310,00 310,00 300,00 300,00 300,00 300,00 300,00 300,00 Potenza 320W Resistive value Resistive value Resistive value Resistive value Resistive value Resistive value Resistive value Resistive value Resistive value 1Ω 3,3 Ω 10 Ω 33 Ω 100 Ω 330 Ω 1000 Ω 3300 Ω 10000 Ω 7PRN322 540,00 460,00 460,00 400,00 415,00 390,00 390,00 390,00 390,00 Potenza 640W Resistive value Resistive value Resistive value Resistive value Resistive value Resistive value Resistive value Resistive value Resistive value 0,5 Ω 1,6 Ω 5Ω 16,5 Ω 50 Ω 165 Ω 500 Ω 1650 Ω 5000 Ω 7PRN642 1060,00 880,00 880,00 855,00 755,00 755,00 755,00 755,00 790,00 Potenza 960W Resistive value Resistive value Resistive value Resistive value Resistive value Resistive value Resistive value Resistive value Resistive value 0,33 Ω 1,1 Ω 3,33 Ω 11 Ω 33 Ω 110 Ω 333 Ω 1100 Ω 3330 Ω 7PRN962 1380,00 1175,00 1215,00 1125,00 1015,00 1005,00 1005,00 1005,00 1045,00 THREE-PHASE Power 3x320W Resistive value Resistive value Resistive value Resistive value Resistive value Resistive value Resistive value Resistive value Resistive value 3x1 Ω 3x3,3 Ω 3x10 Ω 3x33 Ω 3x100 Ω 3x330 Ω 3x1000 Ω 3x3300 Ω 3x10000 Ω 7PRN3/322 1380,00 1125,00 1125,00 1125,00 1015,00 1015,00 1015,00 1015,00 1015,00 57 07 listino GB TA prezzi ITA:listino ITA 15/11/10 16:19 Pagina 58 CURRENT TRANSFORMERS - NANO SERIES STANDARD CLASSES High temperature resistant case suffix RT (Vampmid 66 2530 V0 P60 - softening temperature max 250°C) Price increase 10% Secondary current 5A standard (example code TCSN3 80A); Secondary current 1A (example code TCSN31 80A) price = Secondary current 5A x coefficent 1,4 Single-phase TCSNPDE1 40,00 1A 1A 40,00 5A 5A 40,00 10 A 10A 40,00 15 A 15A 40,00 20 A 20A 40,00 25 A 25A 40,00 30 A 30A 40,00 40 A 40A 50 A 50A 60 A 60A 75 A 75A 80 A 80A 100 A 100A 120 A 120A 125 A 125A 150 A 150A 200 A 200A 250 A 250A 300 A 300A 400 A 400A 500 A 500A 600 A 600A 750 A 750A 800 A 800A 1000 A 1k0A 1200 A 1k2A 1250 A 1k25A 1500 A 1k5A Singlephase 100 A 100A 120 A 120A 125 A 125A 150 A 150A 200 A 200A 250 A 250A 300 A 300A 400 A 400A 500 A 500A 600 A 600A 750 A 750A 800 A 800A 1000 A 1k0A 1200 A 1k2A 1250 A 1k25A 1500 A 1k5A 1600 A 1k6A 2000 A 2k0A 2500 A 2k5A 3000 A 3k0A 4000 A 4k0A TCSN54 Singlephase 400 A 400A 500 A 500A 600 A 600A 750 A 750A 800 A 800A 1000 A 1k0A 1200 A 1k2A 1250 A 1k25A 1500 A 1k5A 1600 A 1k6A 2000 A 2k0A 2500 A 2k5A 3000 A 3k0A 4000 A 4k0A TCSN8V 34,30 38,85 38,85 38,85 43,55 43,55 51,80 51,80 51,80 51,80 75,40 75,40 58 29,00 29,00 29,70 31,10 31,10 32,10 33,80 34,10 36,50 40,00 44,00 48,50 TCSNPD1 64,00 64,00 64,00 64,00 64,00 64,00 64,00 64,00 TCSN6 TCSNPDE2 TCSNPD2 48,00 48,00 48,00 48,00 60,00 60,00 60,00 60,00 68,00 68,00 68,00 68,00 68,00 72,00 72,00 72,00 76,00 84,00 84,00 84,00 84,00 84,00 TCSN65 TCSN622 TCSN22D TCSN320D 14,95 14,95 14,95 14,95 14,95 14,95 14,95 14,95 14,95 14,95 14,95 14,95 18,05 18,05 18,05 18,05 18,05 18,05 18,05 18,05 18,05 TCSN645 TCSN8 44,80 44,80 47,90 47,90 51,50 58,70 58,70 59,75 59,75 64,90 66,95 56,20 56,20 64,90 64,90 64,90 69,00 83,20 83,20 83,20 90,45 104,35 104,35 . 50,20 50,20 50,20 52,00 52,00 42,00 42,00 44,00 46,00 48,00 48,00 50,50 54,20 54,20 74,15 74,15 83,00 42,00 42,00 44,00 46,00 48,00 48,00 50,50 54,20 54,20 74,15 74,15 83,00 TCSN10V2 TCSN10V3 51,50 51,50 56,65 56,65 61,80 66,95 66,95 72,10 72,10 85,50 103,00 113,00 51,50 51,50 56,65 56,65 61,80 66,95 66,95 72,10 72,10 85,50 103,00 113,00 139,05 TCSN3D 18,05 18,05 18,05 18,05 18,05 18,05 18,05 18,05 19,45 19,45 21,40 22,50 26,05 26,05 TCSN832 66,20 66,20 74,90 74,90 74,90 79,00 93,20 93,20 TCSN4D 22,50 22,50 25,30 25,30 26,30 28,35 28,35 31,30 31,30 TCSN4D3 TCSN432 28,55 28,55 28,55 28,55 28,55 28,55 28,55 28,55 28,55 28,55 29,70 31,30 34,10 37,00 37,00 18,05 18,05 18,05 18,05 18,05 18,05 18,05 18,05 19,45 19,45 21,40 22,50 26,05 26,05 TCSN5 31,95 31,95 37,00 37,00 39,75 39,75 43,25 48,95 48,95 49,95 49,95 TCSN10 TCSN103 TCSN1080 TCSN12 66,95 66,95 66,95 80,35 97,85 97,85 97,85 99,90 113,30 113,30 154,50 154,50 66,95 66,95 66,95 80,35 97,85 97,85 97,85 99,90 113,30 113,30 154,50 154,50 66,95 66,95 66,95 80,35 97,85 97,85 97,85 99,90 113,30 113,30 154,50 154,50 76,20 76,20 76,20 76,20 106,10 108,85 108,85 108,85 108,85 121,55 121,55 161,70 161,70 TCSN12V 71,60 71,60 71,60 82,35 82,35 82,35 82,35 90,95 113,30 123,60 149,35 Three-phase 60 A 60A 75 A 75A 80 A 80A 100 A 100A 120 A 120A 125 A 125A 150 A 150A 200 A 200A 250 A 250A 300 A 300A 400 A 400A 500 A 500A 600 A 600A TCSN20T 51,50 51,50 51,50 51,50 51,50 51,50 51,50 56,65 56,65 TCSN35T 66,95 70,05 80,35 82,40 TCSN535 31,30 34,10 37,00 37,00 40,15 42,25 45,30 45,30 48,95 51,50 Height Width Depth interaxis min. 1 5 10 15 20 25 30 40 50 60 75 80 100 125 150 200 250 300 400 500 600 750 800 1000 1200 1250 1500 1600 2000 2500 3000 Primary Current (A) VERTICAL BAR CABLE 2 3 61,5 105 50 31,5 2 80 146 50 45 3 4 5 6 Class 0,5 Class 0,5 1 3 1 1 1 1,5 1,5 Power (VA) 3 x (10x30) 3 x (30 mm) Power (VA) 3 x (20 mm) EXECUTION Dimensions 3 x (35x10) Passing primary Passing primary HORIZ. BAR TCSN35T TCSN20T CENTRAL SECTION TYPE THREE PHASE 72 60 43 3 3 3 3 3 3 3 3 Class 1 Power (VA) Wound primary TCSNPDE1 87 70 43 6 6 6 6 6 6 6 6 Class 0,5 Power (VA) Wound primary TCSNPD1 72 60 43 3 3 3 3 3 3 3 3 Class 1 87 70 43 6 6 6 6 6 6 6 6 6 6 6 6 Class 0,5 Power (VA) 15x3 (<300A) 25x5 (400/500A) 15x3 included Power (VA) Wound primary TCSNPD2 Wound primary TCSNPDE2 2,5 4 5 5 67 43 44 21,5 1 1 1 1,5 2 3 1,2 Class 0,5 1 3 Power (VA) 20 mm Passing primary TCSN22D 3 5 6 6 71 49 43 24,5 1,5 1,5 1,5 2 3 3 2 Class 0,5 1 3 Power (VA) 20 mm Passing primary TCSN320D 3 3 3 5 6 6 6 71 49 43 24,5 2 2 2 2 2,5 3 Class 0,5 1 Power (VA) 30x10 Passing primary TCSN3D 2,5 2,5 2,5 2,5 6 6 6 6 6 72 60 43 30 3 Class 0,5 1 Power (VA) 40x10 30x10 Passing primary TCSN4D 3 3 5 8 10 10 10 10 72 60 43 30 1,5 2 3 4 4 3 Class 0,5 1 Power (VA) 30x10 Passing primary TCSN4D3 2,5 3 3 5 5 6 6 6 72 60 43 30 2,5 2 2 2,5 3 Class 0,5 1 3 Power (VA) 10x20 21 mm 20x10 30x10 Passing primary TCSN432 SINGLE PHASE 87 70 43 35 2,5 3 4 6 10 10 10 10 10 10 10 20 Class 0,5 Power (VA) Passing primary 50x20 50x10 40x20 TCSN5 87 70 43 35 6 6 10 10 10 10 10 10 10 20 Class 0,5 Power (VA) 35 mm Passing primary TCSN535 6 8 10 15 15 15 15 15 15 15 30 87 70 43 35 8 Class 0,5 1 Power (VA) 40x20 40x10 Passing primary TCSN54 102 84 50 42 6 6 10 10 10 10 15 20 20 20 20 20 Class 0,5 Power (VA) 60x20 50x20 Passing primary TCSN6 102 84 50 42 6 6 10 10 10 10 15 20 20 20 20 20 Class 0,5 Power (VA) 50x30 Passing primary TCSN65 102 84 50 42 5 6 10 15 20 Class 0,5 Power (VA) 22 mm Passing primary TCSN622 6 6 10 10 10 10 15 20 20 20 20 20 20 112 105 55 52,5 102 84 50 42 Class 0,5 Power (VA) 80x30 60x30 Passing primary TCSN8 15 20 20 20 20 20 20 20 40 40 40 Class 0,5 Power (VA) 50 mm Passing primary TCSN645 112 105 55 52,5 5 5 6 10 15 20 30 Class 0,5 Power (VA) 32 mm Passing primary TCSN832 CURRENT TRANSFORMERS RANGE NANO SERIES - STANDARD CLASSES 07 listino GB TA prezzi ITA:listino ITA 15/11/10 16:19 Pagina 59 59 10 10 10 10 10 15 20 20 20 20 20 20 158 138 61 69 10 10 10 10 10 15 20 20 20 20 20 20 158 138 61 69 Height Width Depth interaxis min. Class 0,5 Class 0,5 400 500 600 750 800 1000 1200 1250 1500 1600 2000 2500 3000 4000 Primary Current (A) VERTICAL BAR CABLE Power (VA) 3x(100x10) 100x40 80x40 Power (VA) Passing primary Passing primary EXECUTION HORIZ. BAR TCSN103 TCSN10 CENTRAL SECTION Dimensions 60 TYPE 158 138 61 69 10 10 10 10 10 15 20 20 20 20 20 20 Class 0,5 Power (VA) 80 mm Passing primary TCSN1080 182 175 64 87,5 10 10 10 15 20 20 20 20 20 30 40 40 50 Class 0,5 Power (VA) Passing primary 125x50 100x50 80x50 TCSN12 142 102 63 51 10 10 10 10 10 10 10 10 10 10 20 20 Class 0,5 Power (VA) 30x80 Passing primary TCSN8V 165 95 50 47,5 6 6 8 8 10 10 10 10 10 15 20 20 Class 0,5 Power (VA) 20x100 Passing primary TCSN10V2 165 115 50 57,5 6 6 8 8 10 10 10 10 10 15 20 20 20 Class 0,5 Power (VA) 30x100 Passing primary TCSN10V3 187 107 63 53,5 10 10 10 10 10 12 12 15 20 20 20 Class 0,5 Power (VA) 35x125 Passing primary TCSN12V SINGLE PHASE 07 listino GB TA prezzi ITA:listino ITA 15/11/10 16:19 Pagina 60 07 listino GB TA prezzi ITA:listino ITA 15/11/10 16:19 Pagina 61 MEASURING OR PROTECTON TRANSFORMERS RANGE Measuring or Protection CTs can be manufactured on request Terminals with sealable cover, can be fixed on 4 different positions to specify when ordering: Position A = on the higher long side: Position B = on the higher short side; Position C = on the frontal long side; Position D = on the frontal short side In absence of informations, terminals will be always fixed on position “A” These CTs can be supplied with Resin (R) or Air (O) insulation Primary currents from 1000A to 10000A Secondary currents 5A or 1A Class and power (VA) on request 110x170 mm for vertical bars 170x110 mm for horizontal bars 130x140 mm for vertical bars 140x130 mm for horizontal bars TCSN1117 . ON ICE EST R P QU RE TCSN1711 TCSN1314 TCSN1413 . . . ADJUSTABLE CURRENT TRANSFORMERS Modularity of thermoplastic case technology, permits to obtain current transformers (resin insulation) with different internal and external dimensions, reducing costs and delivery times Measuring or Protection CTs can be manufactured on request Maximum dimensions: internal 205x210 mm; external 265x310mm Vertical or horizontal bars Secondary currents 5A or 1A Class and power (VA) on request ON TAA..... ICE EST R P Primary currents from 1000A to 10000A . U Q RE PROTECTION CURRENT TRANSFORMERS The C.T. when used as a current generator for protection relays has electrical characteristics which differ from those of the measuring transformer. Infact the measuring C.T. is expected to give a saturation of the magnetic circuit with 5P in primary currents while, in the case of protective C.T., it is necessary for the secondary current value to follow the increase in the primary current up to 10-15-20 In, so as to guarantee the intervention of the relay in the case of unforeseen breakdown current. It is important not to load the C.T. with a P performance which is greater than that indicated, so as not to modify the saturation value of the C.T.P=RI2 where: P= load on the C.T. R= resistance of the relay + resistance of the cables I= nominal secondary current of the C.T. Secondary current 5A standard (example of code TCSN8/P 1k2A 5P5) Secondary current 1A (example of code TCSN81/P 1k2A 5P5) price = Secondary current 5A x multiplicator 1,4 Classes 5P5, 5P10, 5P15, 5P20 to specify when ordering ON T ICE PR UES Q RE 1200 1500 2000 2500 3000 4000 5000 6000 A A A A A A A A 1k2A 1k5A 2k0A 2k5A 3k0A 4k0A 5k0A 6k0A TCSN8/P . . . . . TCSN103/P . . . . . . TCSN12/P . . . . TCSN8V/P . . . . TCSN10V3/P TCSN12V/P TCS126/P . . . . . . . . . . . . . . TCS200/P TCS166V/P . . . . . . . . . . . TCSN1117/P TCSN1314/P . . . . . . . . . . . . PASSIVE SPLIT CURRENT SENSOR Input signal 100A is converted into an output signal 4/20mA (4mA=0; 20mA=100A) This solution permits a quick installation in already existing panels or nets as that it is not necessary to disconnect the power cable as needed by the classic current transformers. This CT accepts a cable diameter 12mm maximum and its position on the cable doesn’t influence the readings. Measure up to 100A ON ICE EST R P QU RE ø12mm max 100A max + + - - 20 ... 30VDC Analogue Output 4/20mA SCSP100A-4/20mA . 61 07 listino GB TA prezzi ITA:listino ITA 15/11/10 16:19 Pagina 62 SPLIT CORE CURRENT TRANSFORMERS Secondary current 5A standard (example of code TCSA40 100) Secondary current 1A (example of code TCSA60 100 1) price = Secondary current 5A x multiplicator 1,4 Put the accessories on the upper sides and seal them if necessary 100 A 150 A 250 A 300 A 400 A 500 A 600 A 800 A 1000 A Accessory to seal terminals (minimum 10 pcs) Base for wall mounting Accessory for cable centering (TCSA40) Accessory for cable centering (TCSA60) Sealable terminals cover for cable Ø max 40 mm for cable Ø max 60 mm 100A 150A 250A 300A 400A 500A 600A 800A 1k0A TCSA40 133,90 133,90 133,90 133,90 154,50 154,50 154,50 154,50 216,30 TCSA60 ATCSASIG ABASETCSA 180,25 180,25 200,85 200,85 200,85 236,90 • • ACENT40 ACENT60 ATCS3C ON T ICE PR UES Q RE • • 4,80 • • Secondary current 5A standard (example of code TARA100 600A) Secondary current 1A (example of code TARA100 600A 1) price = Secondary current 5A x multiplicator 1,4 500 A 500A 600 A 600A 800 A 800A 1000 A 1k0A 1200 A 1k2A 1250 A 1k25A 1500 A 1k5A 2000 A 2k0A 2500 A 2k5A 3000 A 3k0A 4000 A 4k0A 5000 A 5k0A 6000 A 6k0A Sealable terminals cover (TARA100 except) for cable Ø max 100 mm or horizontal bar 100x10mm for horizontal bar 120x10 - 2x120x10 - 3x120x10 mm for vertical bar 100x10 - 2x100x10 - 3x100x10 mm for vertical 2x80x5 - 2x80x10 - 3x80x5 - 5x80x5 - 2x100x5 - 3x100x5 - 4x100x5 100x10 - 2x100x10 - 5x100x5 - 3x120x10 - 2x125x5 mm for vertical bar 2x80x5 - 2x80x10 - 3x80x5 - 5x80x5 - 2x100x5 - 3x100x5 - 4x100x5 100x10 - 2x100x10 - 5x100x5 - 3x120x10 - 2x125x5 - 2x160x10 mm for horizontal bar 120x10 - 2x120x10 - 3x120x10 mm for vertical bar 200x10 - 2x200x10 - 3x200x10 mm OVERLOAD CURRENT TRANSFORMERS Secondary current 5A standard example of code TARSV 50(200) Secondary current 1A example of code TARSV1 50(200) price = Secondary current 5A x multiplicator 1,4 Possible overload of 400% Sealable terminals cover included 50 (200) A 100 (400) A 200 (800) A 62 50(200) 100(400) 200(800) TARSV 151,40 151,40 166,85 TARA100 214,75 214,75 221,45 226,60 232,80 232,80 238,45 250,30 TARA105 328,05 328,05 346,10 346,10 360,50 370,80 387,80 TARA126 315,70 328,05 339,90 352,25 370,80 TARA166 TARA200 412,00 435,70 447,00 465,55 489,25 537,65 370,80 370,80 370,80 370,80 381,10 393,45 412,00 447,00 471,75 494,40 ATCS1C 1,25 • • • • • TOROIDAL CURRENT TRANSFORMERS These transformers are used when it is necessary to survey the homopolar currents(imbalance of current existing on a three phase cable) or in those cases where substantial performance is necessary) The dimensions are not pre-determined but calculated each time on the basis of the technical characteristics required With passing primary cable Running temperature: - 25°C ÷ +40°C. If immersed in oil, the maximum running temperature rises to 60°C Finished with cotton taping protected with insulating epoxy varnish TART When ordering, indicate: ON - primary current value (min. 50A) T ICE - secondary current value (min. 1A) PR UES Q - precision class E R - burden (VA) - internal diameter The external diameter and the thickness are variable according to the above mentioned data • 07 listino GB TA prezzi ITA:listino ITA 15/11/10 16:19 Pagina 63 SATURABLE TRANSFORMERS RANGE FOR THERMAL RELAYS Saturable CTs are designed to have a special saturation curve in order to prevent unwanted and untimely trips of thermal relays during electric machine’s start-up. These CTs could be of two different types: normal starting application or heavy starting application. Insulation class II Test voltage 3 kV, 50Hz for 1 minute Insulation reference 0,72 kV Tropicalized execution Rated short time termal current Ith 60 In x 1 minute Rated dinamic current Idyn 2,5 Ith x 1 minute Frequency 40/60Hz Standard EN 60044-1 Normally starting saturable CTs are manufactured with a saturation between 3,5 In and 4,5 In. Heavy starting saturable CTs are manufactured with a saturation between 1,3 In and 2,5 In. NORMAL STARTING 1A 5A 10A 15A 20A 25A 30A 40A 50A 60A 75A 80A 100A 120A 125A 150A 200A 250A 300A 400A 500A 600A TCSNPD1...TR . . . . . . TCSNPD2...TR . . . . . . TCSN22D...TR HEAVY STARTING TCSN3D...TR TCSN4D...TR ON ICE EST R P QU RE . . . . . . . . . . . . . . . TCSNPD1...TRH TCSNPD2...TRH TCSN22D...TRH TCSN3D...TRH . . . . . . . . ON . ICE EST . R P QU . RE . . . . . . . . . TCSN4D...TRH . . . . . . . CURRENT TRANSFORMERS - MINI SERIES STANDARD CLASSES TYPE TAM3D TAM4D 15,45 15,45 17,50 17,50 18,55 18,55 24,70 19,70 19,70 19,70 22,85 22,85 22,85 25,05 25,05 26,45 TAM5D 22,15 22,15 22,15 22,15 24,25 26,30 26,30 35,65 35,65 35,65 CENTRAL SECTION TAM6 31,20 31,20 34,85 34,85 39,70 40,50 47,80 47,80 47,80 54,80 25 x 25 30 x 20 40 x 10 23 30 TAM 5D TAM 6 50 x 12 50x23 63x20 2 x 22 25 x 25 30 x 20 40 x 10 VERTICAL BAR Height Width Depth interaxis min. Dimensions TAM1D 14,50 14,50 14,50 14,50 14,50 14,65 14,65 14,65 20 x 12 25 x 15 30 x 10 21 CABLE 40 50 60 75 80 100 120 125 150 200 250 300 400 500 600 800 1000 1200 1250 1500 2000 TAM 4D Passing primary HORIZ. BAR Primary Current (A) 40A 50A 60A 80A 100A 150A 200A 250A 300A 400A 500A 600A 800A 1k0A 1k2A 1k5A 1k6A 2k0A TAM 3D EXECUTION High temperature resistant case suffix RT (Vampmid 66 2530 V0 P60 - softening temperature max 250°C) Price increase 10% Secondary current 5A standard (example code TAM1D 60A) Secondary current 1A (example code TAM1D1 60A) price = Secondary current 5A x coefficent 1,4 40 A 50 A 60 A 80 A 100 A 150 A 200 A 250 A 300 A 400 A 500 A 600 A 800 A 1000 A 1200 A 1500 A 1600 A 2000 A TAM 1D Power (VA) Power (VA) Power (VA) Power (VA) Power (VA) Class 0,5 1 3 Class 0,5 1 Class 0,5 1 Class 0,5 1 Class 0,5 1,3 1,5 1,5 1,5 2 2 3 3 4 3 3 2 2 3 65 52 27 3 3 3 3 4 6 1,5 1,5 1,5 3 3 6 10 10 10 65 52 27 81,5 70 44 3 4 4 6 6 10 10 81,5 70 44 5 6 6 6 10 10 15 15 20 20 106 101 44 63 07 listino GB TA prezzi ITA:listino ITA 15/11/10 16:19 Pagina 64 CURRENT TRANSFORMERS - SMALL SERIES STANDARD CLASSES High temperature resistant case suffix RT (Vampmid 66 2530 V0 P60 - softening temperature max 250°C) Price increase 10% Secondary current 5A standard (example code TCS18 80A) Secondary current 1A (example code TCS181 80A) price = Secondary current 5A x coefficent 1,4 40 A 50 A 60 A 75 A 80 A 100 A 120 A 125 A 150 A 200 A 250 A 300 A 400 A 500 A 600 A 40A 50A 60A 75A 80A 100A 120A 125A 150A 200A 250A 300A 400A 500A 600A 200A 200A 250A 250A 300A 300A 400A 400A 500A 500A 600A 600A 750A 750A 800A 800A 1000A 1k0A 1200A 1k2A 1250A1k25A 1500A 1k5A 1600A 1k6A 2000A 2k0A 2500A 2k5A 3000A 3k0A 4000A 4k0A 5000A 5k0A 6000A 6k0A TCS08 30,20 30,20 30,20 30,20 30,20 30,20 30,20 30,20 30,20 TCS012 TCSM15 19,15 19,15 19,15 19,15 19,15 19,15 19,15 19,15 19,15 TCS13 19,15 19,15 19,15 19,15 19,15 19,15 19,15 19,15 19,15 TCS16 TCS126 TCS200 TCS65V 35,95 35,95 35,95 35,95 37,70 37,70 37,70 37,70 43,45 43,45 43,45 19,15 19,15 19,15 19,15 19,15 19,15 19,15 31,30 31,30 31,30 31,30 31,30 31,30 TCS64 35,95 35,95 35,95 35,95 37,70 37,70 43,45 43,45 43,45 43,45 43,45 TCS647 35,95 35,95 35,95 35,95 37,70 37,70 37,70 37,70 37,70 37,70 37,70 47,60 47,60 121,65 121,65 139,05 139,05 139,05 150,70 162,35 144,80 144,80 162,25 162,25 162,25 174,05 185,40 202,90 237,95 260,60 284,30 TCS18 21,40 21,40 21,40 21,40 21,40 21,40 21,40 21,40 21,40 21,40 21,40 21,40 TCS25 21,40 21,40 21,40 21,40 21,40 21,40 21,40 21,40 21,40 21,40 21,40 21,40 21,40 TCS126V TCS166V 110,20 110,20 110,20 110,20 110,20 110,20 110,20 110,20 121,65 121,65 133,90 144,80 TCS26 TCS32 TCS33 19,15 19,15 19,15 19,15 19,15 19,15 19,15 21,40 21,40 21,40 21,40 21,40 21,40 21,40 21,40 21,40 21,40 21,40 21,40 21,40 21,40 21,40 21,40 21,40 25,50 25,50 25,50 115,90 127,40 127,40 139,05 150,70 185,40 215,25 224,55 SPECIAL CLASSES 100A 120A 125A 150A 200A 250A 300A 600A 750A 800A 1000A 1200A 1250A 1500A 1600A 2000A 2500A 3000A 4000A 64 100A 120A 125A 150A 200A 250A 300A 600A 750A 800A 1k0A 1k2A 1k25A 1k5A 1k6A 2k0A 2k5A 3k0A 4k0A TCS18 0.2S • • • • • • • TCS18 0.2 • • • • • • • TCS18 0.5S TCS647 0.2S • • • • • • • • • • • • • • • N SO ICE EST R P QU RE N SO ICE EST R P QU RE N SO ICE EST R P QU RE N SO ICE EST R P QU RE TCS647 0.2 • • • • • • • • TCS647 0.5S TCS126 0.2S • • • • • • • • TCS126 0.2 TCS126 0.5S TCS200 0.2S • • • • • • • • • • • • • • • • • • TCS200 0.2 TCS200 0.5S • • • • • • • • • • • • Height Width Depth interaxis min. 40 50 60 75 80 100 120 125 150 200 250 300 400 500 600 800 1000 1200 1250 1500 2000 2500 3000 4000 5000 6000 Primary Current (A) VERTICAL BAR CABLE 5 5 5 5 5 5 90,5 56 53,3 3 4 5 90,5 56 53,3 5 10 10 10 10 10 Class 0,5 3 Class 1 Power (VA) 3 5 5 5 1 85 35,5 58 35 Class 2 2 3 3 3 3 Power (VA) 15 TCS TCS M15 012 Bolt 2 DIN M12 MODULES Power (VA) Bolt M8 EXECUTION HORIZ. BAR TCS 08 TYPE 3 5 5 5 1 58 34,5 53,3 27 Class 2 2 3 3 3 3 Power (VA) 13 TCS 13 3 5 5 5 1 58 34,5 53,3 27 Class 3 3 3 3 Power (VA) 11 15 x 5 TCS 16 3,5 5 5 5 90,5 56 53,3 45 2,5 3 3 1,5 3 3 3 5 Class 0,5 1 3 Power (VA) 18 TCS 18 3,5 5 6 6 10 90,5 56 53,3 45 2,5 3 3 1,5 3 3 3 5 Class 0,5 1 3 Power (VA) 25 TCS 25 72 44 53,3 35 3 5 5 5 5 5 Class 0,5 1 Power (VA) 15 x 5 20 x 5 min 25x5 max 25x6,5 5 TCS 32 5 5 5 6 10 10 90,5 56 53,3 45 3 3 3 3 Class 0,5 1 Power (VA) 32 Passing primary TCS 26 TCS 64 TCS 647 TCS 126 TCS 200 90,5 56 53,3 45 - 35 3,5 3,5 5 5 1,5 1,5 1,5 2 3 3,75 Class 0,5 1 Power (VA) 32 x 5 116 87 53,3 70 - 50 5 10 10 10 15 15 15 2 5 5 Class 0,5 1 Power (VA) 50x5 2x50x5 2x50x10 3x50x5 116 87 53,3 70 - 50 5 7,5 7,5 10 15 15 15 15 5 5 5 Class 0,5 1 Power (VA) 207 172 49 10 10 10 15 15 15 Class 0,5 Power (VA) min 40 x 5 2 x 40 x 5 100x10 ÷ 2 x 40 x 10 max 3 x 40 x 5 3x100x10 TCS 65V TCS TCS 126V 166V 10 15 15 15 20 30 30 30 30 30 290 272 49 Class 0,5 Power (VA) 119 70 53,3 45 1 1 3 5 10 10 10 15 15 15 Class 0,5 Power (VA) 200 130 49 75 5 10 10 10 15 15 15 20 20 20 Class 0,5 Power (VA) 237 130 50 75 20 20 20 20 20 30 30 Class 0,5 Power (VA) min min min min 200x10 2x63x5 2x80x5 2x80x5 ÷ ÷ ÷ ÷ max max max max 3x200x10 3x63x5 2x125x10 2x160x10 min 29x5 min 30x5 min 30x30 min 120x10 min 120x10 max 2x32x5 max 2x63x5 max 3x50x5 max 3x120x10 max 3x120x10 TCS 33 STANDARD CLASSES TYPE Height Width Depth interaxis min. 40 50 60 75 80 100 120 125 150 200 250 300 400 500 600 800 1000 1200 1250 1500 2000 2500 3000 4000 Primary Current (A) VERTICAL BAR CABLE HORIZ. BAR EXECUTION CENTRAL SECTION Dimensions CENTRAL SECTION Dimensions 1,5 1,5 1,5 1,5 1,5 1,5 1,5 0,2S TCS 126 Power (VA) 40 x 5 2 x 40 x 5 2 x 40 x 10 3 x 40 x 5 min 30x30 max 3x50x5 Power (VA) min 100x10 ÷ max 3x100x10 min 120x10 max 3x120x10 Passing primary TCS 647 Power (VA) min 200x10 ÷ max 3x200x10 min 120x10 max 3x120x10 TCS 200 90,5 56 53,3 45 1,5 1,5 1,5 1,5 1,5 1,5 1,5 2,5 2,5 2,5 3,5 5 5 7,5 3 3 3 4 4 4 116 87 53,3 70 - 50 3 3 4 5 5 5 10 10 15 15 15 15 3 4 4 5 207 172 49 5 6 6 8 10 10 10 15 3 5 10 15 20 10 15 20 30 40 290 272 49 10 15 20 30 40 Class Class Class Class 0,2 0,5S 0,2S 0,2 0,5S 0,2S 0,2 0,5S 0,2S 0,2 0,5S Power (VA) 18 TCS 18 SPECIAL CLASSES CURRENT TRANSFORMERS RANGE - SMALL SERIES 07 listino GB TA prezzi ITA:listino ITA 15/11/10 16:19 Pagina 65 65 07 listino GB TA prezzi ITA:listino ITA 15/11/10 16:19 Pagina 66 CURRENT TRANSFORMERS - STANDARD SERIES STANDARD CLASSES High temperature resistant case suffix RT (Vampmid 66 2530 V0 P60 - softening temperature max 250°C) Price increase 10% Secondary current 5A standard (example code TAR6 800A) Terminals cover included CT for Certification (example code TAR4D 600AU) Secondary current 1A (example code TAR61 800A) price = Secondary current 5A x coefficent 1,4 1A 5A 10 A 15 A 20 A 25 A 30 A 40 A 50 A 60 A 80 A 100 A 125 A 150 A 200 A 250 A 300 A 400 A 500 A 600 A 750 A 800 A 1A 5A 10A 15A 20A 25A 30A 40A 50A 60A 80A 100A 125A 150A 200A 250A 300A 400A 500A 600A 750A 800A 200 A 250 A 300 A 400 A 500 A 600 A 750 A 800 A 1000 A 1200 A 1250 A 1500 A 1600 A 2000 A 2500 A 3000 A 4000 A 200A 250A 300A 400A 500A 600A 750A 800A 1k0A 1k2A 1k25A 1k5A 1k6A 2k0A 2k5A 3k0A 4k0A TARPDE1 31,95 31,95 31,95 31,95 31,95 31,95 31,95 33,65 TARPDE2 TARPD1 42,55 42,55 42,55 42,55 42,55 42,55 42,55 42,55 33,15 33,15 33,15 42,25 42,25 42,25 TAR5 31,95 31,95 37,00 37,00 39,75 39,75 43,25 43,25 48,95 49,95 49,95 53,95 TARPD2 42,55 42,55 46,95 46,95 46,95 47,90 47,90 47,90 47,90 47,90 49,25 TAR6 TAR8 45,20 45,20 45,20 51,50 51,50 51,50 56,20 56,20 56,20 65,40 65,40 74,15 56,20 56,20 64,90 64,90 64,90 69,00 83,20 83,20 83,20 90,45 104,35 104,35 152,05 TAR12 76,20 76,20 76,20 76,20 106,10 108,85 108,85 108,85 108,85 121,55 121,55 162,25 162,25 TAR0 TAR1D 14,95 14,95 14,95 14,95 14,95 14,95 14,95 14,95 14,95 18,05 18,05 18,05 18,05 18,05 18,05 18,05 19,45 19,45 TAR8V TAR12V 34,30 37,80 37,80 37,80 43,55 43,55 51,80 51,80 51,80 51,80 75,40 75,40 71,85 71,85 78,25 78,25 78,25 78,25 90,95 90,95 TAR3D 18,05 18,05 18,05 18,05 18,05 18,05 19,45 19,45 21,40 22,50 26,05 26,05 TAR4D 22,50 22,50 25,30 25,30 26,30 28,35 28,35 31,30 31,30 SPECIAL CLASSES TAR3D 0.5S 100 A 100A 125 A 125A 150 A 150A 200 A 200A 250 A 250A 300 A 300A 400 A 400A 500 A 500A 600 A 600A 750 A 750A 800 A 800A 1000 A 1k0A 1200 A 1k2A 1500 A 1k5A 600 A 600A 750 A 750A 800 A 800A 1000 A 1k0A 1200 A 1k2A 1500 A 1k5A 1600 A 1k6A 2000 A 2k0A 2500 A 2k5A 3000 A 3k0A 4000 A 4k0A 66 • • • • • • • TAR6 0.2S • • • • • • • TAR4D3 0.2S • • • • • • • TAR4D3 0.2 • • • • • • • TAR4D3 0.5S • • • • • • • TAR4D 0.2S TAR4D 0.2 TAR4D 0.5S • • • • • • • • • • • • • • • • • • • • • • • • TAR6 0.2 • • • • • • • TAR6 0.5S • • • • • • • TAR8 0.2S TAR8 0.2 TAR8 0.5S • • • • • • • • • • • • • • • • • • • • • TAR4D3 27,50 27,50 27,50 27,50 29,70 31,30 34,10 37,00 37,00 PRICES ON REQUEST TAR5 0.2S TAR5 0.2 TAR5 0.5S • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • TAR12 0.2S TAR12 0.2 TAR12 0.5S • • • • • • • • • • • • • • • • • • Height Width Depth 1 5 10 15 20 25 30 40 50 60 80 100 125 150 200 250 300 400 500 600 750 800 1000 1200 1500 1600 2000 2500 3000 4000 Primary Current (A) VERTICAL BAR CABLE HORIZ. BAR EXECUTION TYPE 0,5 3 0,5 75 58 44 75 58 44 3 3 3 3 3 3 75 58 44 75 58 44 6 6 6 6 6 6 6 6 6 6 6 3 3 3 5 67 55 35 3 2 2 3 3 3 3 3 5 75 58 44 3 Class 1 6 6 6 6 6 6 6 6 3 0,5 2 3 3 3 2,5 3 3 5 5 6 6 6 75 58 44 2,5 Class 1 3 2 2 3 6 10 10 10 10 10 87 75 44 3 4 6 Class 0,5 1 87 75 44 3 3 5 6 10 10 10 10 10 Class 0,5 Power (VA) 30x10 20 x 25 30 x 20 40 x 10 20 x 10 Power (VA) 25 32 21 Power (VA) TAR 5 TAR 6 TAR 8 TAR 12 100 85 45 3 4 6 10 10 10 10 10 10 20 4 Class 0,5 1 Power (VA) 30 x 10 30 TAR 8V TAR 12V 6 10 10 10 10 10 15 20 20 20 20 20 10 10 10 15 20 20 20 20 30 40 40 50 110 120 175 105 125 180 61 61,5 68,5 6 6 10 10 10 10 15 20 20 20 20 10 10 10 12 12 15 20 119 165 109 109 41 41 6 10 10 10 10 10 10 10 10 20 20 Class Class Class Class Class 0,5 0,5 0,5 0,5 0,5 Power Power Power Power Power (VA) (VA) (VA) (VA) (VA) min min 80x30 100x10 ÷ ÷ max max 3x80x5 4x125x5 50 2 x 30 2 x 50 2 x 35 3 x 35 25x20 30x25 30x30 50x20 60x30 80x50 100x50 30x10 40x10 40x25 - 50x20 60x20 80x30 125x50 TAR 4D3 15 Class 1 3 3 3 3 3 3 3 3 TAR 4D Passing primary TAR 3D 20 x 3 20 TAR 1D 20 x 10 30 x 10 TAR 0 Class Class Class Class 1 1 0,5 0,5 included 25x3 25x5 TAR PD 2 Wound primary Power (VA) TAR PD 1 Wound primary Power (VA) included 15 x 3 TAR PD E2 Wound primary Power Power Power Power (VA) (VA) (VA) (VA) TAR PD E1 Wound primary STANDARD CLASSES TYPE Height Width Depth 80 100 125 150 200 250 300 400 500 600 750 800 1000 1200 1500 1600 2000 2500 3000 4000 Primary Current (A) VERTICAL BAR CAVO HORIZ. BAR EXECUTION CENTRAL SECTION Dimensions CENTRAL SECTION Dimensions 75 58 44 1,5 2 2 1,5 1,5 1,5 2 1,5 2 2 3 3 3 4 4 87 75 44 1,5 2 2 3 3 4 4 4 1 1,5 2 2 3 3 4 5 5 1,5 1,5 1,5 1,5 1,5 1,5 1,5 87 75 44 1,5 1,5 1,5 1,5 1,5 1,5 1,5 2,5 2,5 3,5 5 5 7,5 10 2 2 3 3 3 3 4 5 6 6 100 85 45 2 2 3 3 4 4 4 5 6 6 Power (VA) 2 2 3 3 4 4 5 5 6 6 4 4 4 5 5 5 5 110 105 61 5 5 5 5 5 5 5 Power (VA) 6 6 6 6 6 6 6 5 5 5 10 10 10 10 120 125 61,5 5 5 5 10 10 10 10 Power (VA) 6 6 6 15 15 15 15 10 10 15 20 20 30 10 10 15 20 20 30 175 180 68,5 Power (VA) 20 25 30 35 40 50 Class Class Class Class Class Class 0,2 0,5S 0,2S 0,2 0,5S 0,2S 0,2 0,5S 0,2S 0,2 0,5S 0,2S 0,2 0,5S 0,2S 0,2 0,5S 0,2S Class 0,5S Power (VA) Power (VA) Power (VA) 30 x 10 2 x 50 30 x 10 2 x 30 20 x 25 30 x 20 40 x 10 50 20x10 80x50 100x50 125x50 TAR 12 30 60x30 80x30 TAR 8 25 50x20 60x20 TAR 6 32 21 Passing primary TAR 5 30x30 40x25 - 50x20 TAR 4D3 30x10 25x20 30x25 40x10 TAR 4D 20x10 30x10 TAR 3D SPECIAL CLASSES CURRENT TRANSFORMERS RANGE - STANDARD SERIES 07 listino GB TA prezzi ITA:listino ITA 15/11/10 16:19 Pagina 67 67 07 listino GB TA prezzi ITA:listino ITA 15/11/10 16:19 Pagina 68 PROTECTION CURRENT TRANSFORMERS The C.T. when used as a current generator for protection relays has electrical characteristics which differ from those of the measuring transformer. Infact the measuring C.T. is expected to give a saturation of the magnetic circuit with 5P in primary currents while, in the case of protective C.T., it is necessary for the secondary current value to follow the increase in the primary current up to 10-15-20 In, so as to guarantee the intervention of the relay in the case of unforeseen breakdown current. It is important not to load the C.T. with a P performance which is greater than that indicated, so as not to modify the saturation value of the C.T.P=RI2 where: P= load on the C.T. R= resistance of the relay + resistance of the cables I= nominal secondary current of the C.T. Secondary current 5A standard (example of code TAR5/P 800A 5P5) Secondary current 1A (example of code TAR51/P 800A 5P5) price = Secondary current 5A x multiplicator 1,4 Classes 5P5, 5P10, 5P15, 5P20 to specify when ordering Sealable terminals cover included 5P5 - 5P10 5A 10 A 15 A 20 A 25 A 30 A 40 A 50 A 60 A 80 A 100 A 150 A 200 A 250 A 300 A 400 A 500 A 600 A 800 A 1000 A 1200 A 1500 A 2000 A 2500 A 3000 A 4000 A 5A 10A 15A 20A 25A 30A 40A 50A 60A 80A 100A 150A 200A 250A 300A 400A 500A 600A 800A 1k0A 1k2A 1k5A 2k0A 2k5A 3k0A 4k0A TARPD1/P 44,50 44,50 44,50 44,50 44,50 44,50 44,50 TARPD2/P 44,50 44,50 48,30 48,30 49,25 49,25 49,25 49,25 49,25 49,25 5P5 - 5P10 - 5P15 - 5P20 TAR5/P TAR6/P 32,75 38,10 38,10 40,90 40,90 44,15 46,55 51,20 55,50 46,55 46,55 46,55 46,55 46,55 53,05 53,05 57,90 57,90 TAR8/P 57,90 57,90 57,90 66,85 66,85 70,95 85,70 85,70 107,35 107,35 TAR12/P 103,50 103,50 103,50 103,50 109,20 112,25 112,25 125,15 125,15 166,85 166,85 DOUBLE RATIO CURRENT TRANSFORMERS Secondary current 5A standard Secondary current 1A Double ratio on secondary: Sealable terminals cover included 5-10 A 10-20 A 15-30 A 20-40 A 25-50 A 30-60 A 40-80 A 50-100 A 60-120 A 80-160 A 100-200 A 150-300 A 200-400 A 250-500 A 300-600 A 400-800 A 500-1000 A 600-1200 A 800-1600 A 1000-2000 A 1200-2400 A 1500-3000 A 2000-4000 A 68 5-10A 10-20A 15-30A 20-40A 25-50A 30-60A 40-80A 50-100A 60-120A 80-160A 100-200A 150-300A 200-400A 250-500A 300-600A 400-800A 500-1k0A 600-1k2A 800-1k6A 1k0-2k0A 1k2-2k4A 1k5-3k0A 2k0-4k0A TARPD2/2 60,30 60,30 60,30 60,30 64,05 64,05 64,05 64,05 64,05 64,05 64,05 64,05 64,05 65,90 (example of code TAR4D/2 200-400A) (example of code TAR4D1/2 200-400A) price = Secondary current 5A x multiplicator 1,4 S1-S2 lower ratio S1-S3 higher ratio TAR1D/2 24,20 24,20 24,20 24,20 26,25 29,05 29,05 35,00 TAR3D/2 TAR4D/2 26,55 29,05 29,05 35,00 35,00 30,50 33,50 33,50 38,10 38,10 41,70 TAR5/2 49,25 53,05 53,05 55,65 59,65 59,65 TAR6/2 59,65 59,65 68,40 68,40 75,20 75,20 109,20 109,20 TAR8/2 86,85 92,80 112,25 112,25 139,55 139,55 158,30 TAR12/2 145,45 161,70 161,70 218,35 218,35 07 listino GB TA prezzi ITA:listino ITA 15/11/10 16:19 Pagina 69 DC OUTPUT 4/20 mA CURRENT TRANSFORMERS Power supply 20.....30VDC Test voltage: 0,72kV/3kV 1A 5A 10 A 15 A 20 A 25 A 30 A 40 A 50 A 60 A 80 A 100 A 150 A 200 A 250 A 300 A 400 A 500 A 600 A 800 A 1000 A 1200 A 1500 A 2000 A 2500 A 3000 A 4000 A 5000 A 1/4-20MA 5/4-20MA 10/4-20MA 15/4-20MA 20/4-20MA 25/4-20MA 30/4-20MA 40/4-20MA 50/4-20MA 60/4-20MA 80/4-20MA 100/4-20MA 150/4-20MA 200/4-20MA 250/4-20MA 300/4-20MA 400/4-20MA 500/4-20MA 600/4-20MA 800/4-20MA 1k0/4-20MA 1k2/4-20MA 1k5/4-20MA 2k0/4-20MA 2k5/4-20MA 3k0/4-20MA 4k0/4-20MA 5k0/4-20MA TMAPD1 82,90 82,90 82,90 104,75 104,75 104,75 104,75 104,75 Class 1 Frequency 50 Hz TMAPD2 TMA4D3 104,75 104,75 104,75 98,65 98,65 98,65 98,65 98,65 98,65 104,75 107,85 110,95 114,10 Resistive load 500 ohm Max Sealable terminals cover included TMA5 104,05 104,05 104,05 107,85 110,95 114,10 119,25 119,25 120,30 120,30 120,30 124,00 TMA6 110,95 114,10 117,60 120,50 124,10 124,10 124,10 124,10 124,10 137,00 145,75 TMA8 TMA12 125,15 125,15 125,15 125,15 127,70 127,70 137,00 154,00 165,85 173,05 154,00 154,00 154,00 157,60 157,60 160,70 160,70 163,75 168,90 179,20 193,65 209,10 DC OUTPUT 4/20 mA WITH EXTERNAL POWER SUPPLY Power supply 230VAC (12VDC, 24VDC, 48VDC on request) Resistive load 500 ohm Max Test voltage: 0,72kV/3kV Sealable terminals cover included 1A 5A 10 A 15 A 20 A 25 A 30 A 40 A 50 A 60 A 80 A 100 A 150 A 200 A 250 A 300 A 400 A 500 A 600 A 800 A 1000 A 1200 A 1500 A 2000 A 2500 A 3000 A 4000 A 5000 A 1/4-20MA 5/4-20MA 10/4-20MA 15/4-20MA 20/4-20MA 25/4-20MA 30/4-20MA 40/4-20MA 50/4-20MA 60/4-20MA 80/4-20MA 100/4-20MA 150/4-20MA 200/4-20MA 250/4-20MA 300/4-20MA 400/4-20MA 500/4-20MA 600/4-20MA 800/4-20MA 1k0/4-20MA 1k2/4-20MA 1k5/4-20MA 2k0/4-20MA 2k5/4-20MA 3k0/4-20MA 4k0/4-20MA 5k0/4-20MA TMAAPD1 130,80 130,80 130,80 152,45 152,45 152,45 152,45 152,45 TMAAPD2 TMAA4D3 152,45 152,45 152,45 152,45 152,45 152,45 152,45 152,45 152,45 146,25 146,25 146,25 146,25 146,25 146,25 152,45 156,05 158,60 161,70 TMAA5 152,45 152,45 152,45 156,05 158,60 161,70 166,85 166,85 168,40 168,40 168,40 173,05 Class 1 Frequency 50 Hz TMAA6 156,05 158,60 166,85 168,40 173,05 173,05 173,05 173,05 173,05 185,40 193,65 TMAA8 TMAA12 173,05 173,05 173,05 173,05 176,15 176,15 185,40 201,90 214,25 221,45 221,45 201,90 201,90 201,90 206,00 206,00 209,10 209,10 211,15 217,35 226,60 242,05 257,50 69 07 listino GB TA prezzi ITA:listino ITA 15/11/10 16:19 Pagina 70 DC OUTPUT 0-20 mA AND 0-10V CURRENT TRANSFORMERS Class 1 Test voltage: 0,72kV/3kV Resistive load 500 ohm Max Frequency 50 Hz Sealable terminals cover included For these currents use the correspondent model TAR... secondary 5A in connection with the external accessory TMAPD1-5/20MA Output 20mA 1A 5A 10 A 15 A 20 A 25 A 30 A 40 A 50 A 60 A 80 A 100 A 150 A 200 A 250 A 300 A 400 A 500 A 600 A 800 A 1000 A 1200 A 1500 A Output 20mA Output 10V 1/20MA 5/20MA 10/20MA 15/20MA 20/20MA 25/20MA 30/20MA 40/20MA 50/20MA 60/20MA 80/20MA 100/20MA 150/20MA 200/20MA 250/20MA 300/20MA 400/20MA 500/20MA 600/20MA 800/20MA 1k0/20MA 1k2/20MA 1k5/20MA 1/10V 5/10V 10/10V 15/10V 20/10V 25/10V 30/10V 40/10V 50/10V 60/10V 80/10V 100/10V 150/10V 200/10V 250/10V 300/10V 400/10V 500/10V 600/10V 800/10V 1k0/10V 1k2/10V 1k5/10V TMAPD1 82,90 82,90 82,90 104,75 104,75 104,75 104,75 104,75 For these currents use the correspondent model TAR... secondary 5A in connection with the external accessory TMAPD1-5/20MA Output 20mA 1A 5A 10 A 15 A 20 A 25 A 30 A 40 A 50 A 60 A 80 A 100 A 150 A 200 A 250 A 300 A 400 A 500 A 600 A 800 A 1000 A 1200 A 1500 A 2000 A 2500 A 3000 A 4000 A 70 Output 20mA Output 10V 1/20MA 5/20MA 10/20MA 15/20MA 20/20MA 25/20MA 30/20MA 40/20MA 50/20MA 60/20MA 80/20MA 100/20MA 150/20MA 200/20MA 250/20MA 300/20MA 400/20MA 500/20MA 600/20MA 800/20MA 1k0/20MA 1k2/20MA 1k5/20MA 2k0/20MA 2k5/20MA 3k0/20MA 4k0/20MA 1/10V 5/10V 10/10V 15/10V 20/10V 25/10V 30/10V 40/10V 50/10V 60/10V 80/10V 100/10V 150/10V 200/10V 250/10V 300/10V 400/10V 500/10V 600/10V 800/10V 1k0/10V 1k2/10V 1k5/10V 2k0/10V 2k5/10V 3k0/10V 4k0/10V TMAPD2 TMA4D3 TMAPD1 5/20mA + TAR4D3 ... /5A 104,75 104,75 104,75 98,65 98,65 98,65 98,65 98,65 98,65 104,65 108,15 110,80 114,10 82,90 + 27,50 82,90 + 27,50 82,90 + 29,70 82,90 + 31,30 82,90 + 34,10 82,90 + 36,95 TMA6 TMAPD1 5/20mA + TAR6 ... /5A 110,80 114,10 117,40 120,40 124,10 124,10 124,10 124,10 124,10 137,20 150,60 82,90 + 45,20 82,90 + 45,20 82,90 + 45,20 82,90 + 45,20 82,90 + 45,20 82,90 + 51,50 82,90 + 51,50 82,90 + 56,20 82,90 + 56,20 82,90 + 65,40 82,90 + 74,15 TMA8 TMAPD1 5/20mA + TAR8 ... /5A 125,15 125,15 125,15 125,15 126,70 126,70 137,20 153,90 165,85 172,85 82,90 + 56,20 82,90 + 56,20 82,90 + 64,90 82,90 + 64,90 82,90 + 69,00 82,90 + 83,20 82,90 + 83,20 82,90 + 104,35 82,90 + 104,35 82,90 + 152,00 TMA5 TMAPD1 5/20mA + TAR5 ... /5A 97,30 97,30 97,30 108,15 110,80 114,10 119,25 119,25 120,40 120,40 120,40 124,10 82,90 + 31,95 82,90 + 31,95 82,90 + 31,95 82,90 + 36,95 82,90 + 36,95 82,90 + 39,75 82,90 + 39,75 82,90 + 43,25 82,90 + 48,90 82,90 + 49,95 82,90 + 53,95 TMA12 TMAPD1 5/20mA + TAR12 ... /5A 153,90 153,90 153,90 152,00 154,50 154,50 163,25 169,20 178,70 193,10 82,90 + 76,20 82,90 + 76,20 82,90 + 76,20 82,90 + 106,10 82,90 + 108,85 82,90 + 108,85 82,90 + 121,55 82,90 + 121,55 82,90 + 162,20 82,90 + 162,20 07 listino GB TA prezzi ITA:listino ITA 15/11/10 16:19 Pagina 71 HALL EFFECT CURRENT TRANSFORMERS Power supply 230VAC (12VDC, 24VDC, 48VDC on request) Secondary voltage 10V Class 1 - response time 500 msec Test voltage: 0,72kV/3kV Frequency 50 Hz Sealable terminals cover included Secondary current 4/20 mA or 20mA Resistive load 500 ohm Max ON ES ST C I PR QUE RE Output 4/20mA Output 20mA 1A 5A 10 A 15 A 20 A 25 A 30 A 40 A 50 A 60 A 80 A 100 A 150 A 200 A 250 A 300 A 400 A 1/4-20MA 5/4-20MA 10/4-20MA 15/4-20MA 20/4-20MA 25/4-20MA 30/4-20MA 40/4-20MA 50/4-20MA 60/4-20MA 80/4-20MA 100/4-20MA 150/4-20MA 200/4-20MA 250/4-20MA 300/4-20MA 400/4-20MA 1/20MA 5/20MA 10/20MA 15/20MA 20/20MA 25/20MA 30/20MA 40/20MA 50/20MA 60/20MA 80/20MA 100/20MA 150/20MA 200/20MA 250/20MA 300/20MA 400/20MA Output 10V 1/10V 5/10V 10/10V 15/10V 20/10V 25/10V 30/10V 40/10V 50/10V 60/10V 80/10V 100/10V 150/10V 200/10V 250/10V 300/10V 400/10V TAHPD1 • • • • • • • • TAHPD2 TAH4D3 TAH5 • • • • • • • • • • • • • • • • • • • • • • • • SUMMATION CURRENT TRANSFORMERS For vectorial summation of the current of several phases in a single voltage system. If the primary currents have different ratios, specify the ratios when ordering Secondary current 5A standard (example of code TARS2) Secondary current 1A (example of code TARS21) price = Secondary current 5A x multiplicator 1,4 Sealable terminals cover included range 5+5 A range 5+5+5 A range 5+5+5+5 A power VA TARS2 155,00 TARS3 TARS4 TARSD2 95,35 161,20 10 10 TARSD3 TARSD4 101,45 167,35 10 6 107,65 6 6 RATIO CORRECTING CURRENT TRANSFORMERS These transformers are used when it is necessary to correct the transformation ratio of the main CT in order to adapt it to particular needs on the part of the measuring circuit or the phase displacement caused by star / delta connections, filtering the eventual homopolar currents. Sealable terminals cover included TARCRD Primary current from 0,5 to 40A Secondary current from 0,2 to 10A Primary current from 0,5 to 40A Secondary current from 0,5 to 10A When ordering indicate exactly the primary and secondary current When ordering indicate exactly the primary and secondary current TARCRD1 TARCR2 87,55 113,30 60,25 71 07 listino GB TA prezzi ITA:listino ITA 15/11/10 16:19 Pagina 72 CURRENT TRANSFORMERS FOR ELECTRONIC USE These transformers are used for measuring current from 25A to 600A (nominal primary current). The peculiar characteristic of these transformers is the high number of turns in the secondary cable. This makes it possible to have a very low secondary current, suitable for an electronic measuring circuit. Appliance sphere: - current sensor for circuits which protect motors, UPS and similar; - current sensor for measuring instruments (current probe) Insulation voltage between primary and secondary elements 4kV Frequency: 50 - 60Hz Other characteristics on request 25 A 25 A 50 A 50 A 100 A 100 A 200 A 200 A 300 A 400 A 400 A 600 A 600 A 600 A 25/0,05A 25/0,2A 50/0,05A 50/0,2A 100/0,1A 100/0,2A 200/0,2A 200/0,4A 300/0,2A 400/0,2A 400/0,4A 600/0,2A 600/0,4A 600/0,6A TAMEL 26,80 26,80 26,80 26,80 26,80 26,80 26,80 26,80 26,80 26,80 26,80 39,65 26,80 26,80 TCS25EL TVR20 210,00 210,00 210,00 210,00 210,00 210,00 210,00 210,00 210,00 230,00 230,00 230,00 230,00 230,00 230,00 230,00 230,00 230,00 20 TVR50 320,00 320,00 320,00 320,00 320,00 320,00 320,00 320,00 320,00 370,00 370,00 370,00 370,00 370,00 370,00 370,00 370,00 370,00 50 TVRE50 208,00 208,00 208,00 208,00 208,00 208,00 208,00 208,00 208,00 225,00 225,00 225,00 225,00 225,00 225,00 225,00 225,00 225,00 50 (25) TVRE100 288,00 288,00 288,00 288,00 288,00 288,00 288,00 288,00 288,00 308,00 308,00 308,00 308,00 308,00 308,00 308,00 308,00 308,00 100 (50) 28,00 VOLTAGE TRANSFORMERS Secondary voltage standard: 100V, 100V:√3, 110V, 110V:√3 other on request When ordering indicate exactly the primary and secondary voltages, power, class and frequency Sealable terminals cover included 100 V 110 V 115 V 230 V 380 V 400 V 440 V 500 V 600 V 100 V:√3 110 V:√3 115 V:√3 230 V:√3 380 V:√3 400 V:√3 440 V:√3 500 V:√3 600 V:√3 power VA 100/...V (secondary 110/...V (secondary 115/...V (secondary 230/...V (secondary 380/...V (secondary 400/...V (secondary 440/...V (secondary 500/...V (secondary 600/...V (secondary 100R/...V (secondary 110R/...V (secondary 115R/...V (secondary 230R/...V (secondary 380R/...V (secondary 400R/...V(secondary 440R/...V (secondary 500R/...V (secondary 600R/...V (secondary 100 V 100/...V (secondary 110 V 110/...V (secondary 115 V 115/...V (secondary 230/...V (secondary 230 V 380 V 380/...V (secondary 400 V 400/...V (secondary 440/...V (secondary 440 V 500 V 500/...V (secondary 600/...V (secondary 600 V 100 V:√3 100R/...V (secondary 110 V:√3 110R/...V (secondary 115 V:√3 115R/...V (secondary 230R/...V (secondary 230 V:√3 380 V:√3 380R/...V (secondary 400 V:√3 400R/...V (secondary 440R/...V (secondary 440 V:√3 500R/...V (secondary 500 V:√3 600 V:√3 600R/...V (secondary power VA (power VA for primary and secondary √3) 72 voltage voltage voltage voltage voltage voltage voltage voltage voltage voltage voltage voltage voltage voltage voltage voltage voltage voltage voltage voltage voltage voltage voltage voltage voltage voltage voltage voltage voltage voltage voltage voltage voltage voltage voltage voltage value) value) value) value) value) value) value) value) value) value) value) value) value) value) value) value) value) value) value) value) value) value) value) value) value) value) value) value) value) value) value) value) value) value) value) value) TVR2 100,95 100,95 100,95 100,95 100,95 100,95 100,95 100,95 100,95 110,20 110,20 110,20 110,20 110,20 110,20 110,20 110,20 110,20 2 TVR6 134,00 134,00 134,00 134,00 134,00 134,00 134,00 134,00 134,00 155,00 155,00 155,00 155,00 155,00 155,00 155,00 155,00 155,00 6 TVR10 204,00 204,00 204,00 204,00 204,00 204,00 204,00 204,00 204,00 TVR10R 10 220,00 220,00 220,00 220,00 220,00 220,00 220,00 220,00 220,00 10 TVRE3 64,00 64,00 64,00 64,00 64,00 64,00 64,00 64,00 64,00 76,00 76,00 76,00 76,00 76,00 76,00 76,00 76,00 76,00 3 (1,5) TVRE6 72,00 72,00 72,00 72,00 72,00 72,00 72,00 72,00 72,00 80,00 80,00 80,00 80,00 80,00 80,00 80,00 80,00 80,00 6 (3) TVRE10 108,00 108,00 108,00 108,00 108,00 108,00 108,00 108,00 108,00 116,00 116,00 116,00 116,00 116,00 116,00 116,00 116,00 116,00 10 (5) TVRE20 120,00 120,00 120,00 120,00 120,00 120,00 120,00 120,00 120,00 132,00 132,00 132,00 132,00 132,00 132,00 132,00 132,00 132,00 20 (10) 07 listino GB TA prezzi ITA:listino ITA 15/11/10 16:19 Pagina 73 BAR INSULATORS Insulators made in polyesther material reinforced with fiber glass Halogen and silicone free Dielectric constant 4-5 Water absorption <0,3% Standards ASTM-UL, ISO-IEC, 60439 With threaded metal insert M (ISO) Operating temperature under load >200°C Voltaic arc resistance >180 sec Fire proof V0 Code (without bolts) Code (with bolts) RINS-25 RINS-30 RINS-35 RINS-40 RINS-51 25 500 6 6 M6 28 30 550 8 8 M8 44 35 600 10 10 M8 50 40 650 10 12 M8 86 51 1000 20 15 M8 83 76 1500 40 25 M10 233 25 500 6 6 M6 33 30 550 8 8 M8 52 35 600 10 10 M8 58 40 650 10 12 M8 96 51 1000 20 15 M8 89 76 1500 40 25 M10 245 1,60 1,80 2,00 2,60 2,70 6,10 1,80 2,00 2,25 2,80 2,95 5,60 Height (mm) Tensile strength (Ibs) Torque strength (ft Ibs) Voltage withstand (kV) Bolt Weight (g) Price RINS-76 RINS-25S RINS-30S RINS-35S RINS-40S RINS-51S RINS-76S SHUNTS Secondary 60 mV standard Other primary and secondary values on request When ordering please indicate the needed primary value Class 0,5 from from from from from from 1A to 25A 30A to 60A 80A to 200A 250A to 350A 400A to 500A 600A to 700A SH 25,75 from 1A60MV to 25A60MV from 30A60MV to 60A60MV from 80A60MV to 200A60MV from 250A60MV to 350A60MV from 400A60MV to 500A60MV from 600A60MV to 700A60MV from 750A to 1000A from 1200A to 1500A from 2000A to 2500A 3000A 4000A from 5000A to 6000A SH SH SH SH 25,75 27,30 45,30 57,80 70,05 from 750A60MV to 1K0A60MV from 1K2A60MV to 1K5A60MV from 2K0A60MV to 2K5A60MV 3K0A60MV 4K0A60MV from 5K0A60MV to 6K0A60MV 8000A 10000A 12000A 15000A SH 8K0A60MV 10K0A60MV 12K0A60MV 15K0A60MV SH SH 106,60 SH SH SH SH 138,00 195,20 406,85 458,35 1369,90 SH 2730,00 SH SH SH 2995,00 3280,00 4500,00 ACCESSORIES FOR TRANSFORMERS CERTIFICATIONS FOR ALL MODELS Revalco is able to supply the certification of the measuring groups in case the Customs Technical Department requests it. The certification of the whole plant is to be requested at the competent UTF offices of the area. ACERT-U 123,60 In case of a measuring group with three systems composed of 3 current transformers and one meter, 5 inspection certificates are necessary. When the measuring group to be inspected is a 2 system, 4 certificates are requested as the interested CT are only two. ELECTRONIC PROTECTION PATENTED Electronic circuit for automatic protection against dangers caused by the deconnections of secondary terminals of current transformers (open circuit). S.C.T. SECURITY CURRENT TRANSFORMER 1DIN module version Like terminals cover version for all current transformers for nano series current transformers SEALABLE TERMINALS COVER 1ASCT1 25,00 ASCT 20,00 FIXING COMPONENTS Available up to code TCSN6 Transparent sealable terminals cover for nano series CT ATCS3C 1,20 2 feets + 2 screws for nano series current transformers ASATCSN 2,25 73 08 listino GB media prezzi ITA:listino ITA 15/11/10 16:20 Pagina 74 COR-TCSN... CURRENT TRANSDUCERS Class 1 (total class is made by the sum of the CT and accessory’s class) Response time 500ms Resistive load 300ohm max (>10kohm for model TCSN510-TCSN110) Power supply 52 60 Output signal Signal input 40 ON ES ST C I PR QUE COR-TCSN COR-TCSN COR-TCSN COR-TCSN RE Standard range 510 110 520 120 Input 5A AC output 10VDC • input 1A AC output 10VDC • input 5A AC output 20mADC • input 1A AC output 20mADC • ON External auxiliary supply range ES ST C I Input 5A AC output 4/20mADC supply 230VAC PR QUE RE Input 1A AC output 4/20mADC supply 230VAC Input 5A AC output 4/20mADC supply 24VDC Input 1A AC output 4/20mADC supply 24VDC Input 5A AC output 4/20mADC supply 22...36VAC and 19...70VDC Input 1A AC output 4/20mADC supply 22...36VAC and 19...70VDC Input 5A AC output 4/20mADC supply 44..130VAC and 70..240VDC Input 1A AC output 4/20mADC supply 44..130VAC and 70..240VDC ON ES ST C I PR QUE RE COR-TCSN COR-TCSN 5420 1420 • • Self-supplied range Input 5A AC output 4/20mADC input 1A AC output 4/20mADC COR-TCSN COR-TCSN COR-TCSN COR-TCSN COR-TCSN COR-TCSN COR-TCSN COR-TCSN 5420-230 1420-230 5420-24C 1420-24C 5420-P1 1420-P1 5420-P2 1420-P2 • • • • • • • • FOR SMALL SERIES SEALABLE TERMINALS COVER ATCS1C 1,20 Sealable terminals cover for TCS13, TCS16, TCS26, TCS126, TCS200, TCS126V, TCS166V Sealable terminals cover for TCS08, TCS012, TCS18, TCS25, TCS32, TCS33, TCS64, TCS647, TCS65V ATCS2C 1,60 MEDIUM VOLTAGE SUPPLY AND BATTERY CHARGERS ENEL DK5600 STANDARDS Stabilised supply / Battery charger model 3RAL2410 dedicated to PG protections (General Protections for ENEL DK 5600 standards) is furnished complete with two external batteries 12VDC-5Ah-20Hr. The scope of this device is to maintain always in charge these batteries that in their turn, assure (in case of power failure from the net) the power supply of the connected protection relay, for at least 2 hours, or up to the normal restoration of power supply. 3RAL2410 435,00 Charge current limitation: 10A TOROIDAL CURRENT TRANSFORMERS FOR MEDIUM VOLTAGE INSULATED CABLES Frequency: 40 - 60 Hz Test voltage: 3kV at 50Hz for 1 min Construction following the standards IEC 60044-1 Short circuit nominal thermic curren (Ith) up to 40kA for 1 second Nominal dynamic current (Idyn) = 2,5 Ith Secondaries numbers: 1 or 2 on request Safety factor </= 5 or <= 10 on request Internal use Toroidal trasformers in resin (taped TEN...N on request) Primary nominal current from 40 to 6000A, secondary 5A or 1A to indicate when ordering External diameter / Internal diameter mm Height mm 0,72kV measure or protection ON ES ST C I PR QUE RE TEN70R • 180/70 120 TEN105R • 230/105 60 TEN160R • 275/160 63 TEN210R • 364/210 80 FOR MEDIUM VOLTAGE INSULATED CABLES - ENEL DK5600, CEI 0-16 Ed.II 0,72kV Phase TEN current transformers established by the ENEL DK 5600 standards, are dedicated to power the General Protection(PG) and their principal function is to protect, in selective way, the Energy Distributor net in case of damage. TEN70R/N must power, with acceptable errors, the PG protection within the variable range accepted by the primary current. Standard secondary current 5A (code example TEN70R 300 5/5) Secondary current 1A (code example TEN70R 300 1/1) 300 A in resin, Class 5P30/10VA, secondary 5A 300 A in resin, Class 0,5 - 5P30/10VA, secondary 5A 74 TEN320R • 500/320 80 measure and/or protection N SO ICE EST R P QU RE 300 300 5/5 TEN70R • • 08 listino GB media prezzi ITA:listino ITA 15/11/10 16:20 Pagina 75 FOR MEDIUM VOLTAGE INSULATED CABLES - ENEL DK5600, CEI 0-16 Ed.II 0,72kV 1 Agosto 2008 Ed.25 DISPOSITIVI DI PROTEZIONE GENERALE PER CLIENTI MT DI ENEL DISTRIBUZIONE TA/TAT VERIFICATI ASSOCIABILI A TUTTE LE PROTEZIONI GENERALI DICHIARATE CONFORMI DK5600 ED. V, 06-2006 (cfr. DK5600 §6.2.2 soluzione a) DATA RAPPORTO DI PROVA PRESTAZIONE (VA) MODELLO RAPPORTO UTILIZZO COSTRUTTORE REVALCO REVALCO REVALCO TEN105R TEN105N TEN105RD 100/1 100/1 100/1 2 2 0,5 TAT TAT TAT 14/02/2007 14/02/2007 16/07/2008 protection REVALCO is present on the ENEL vendor list with the Homopolar transformers (as shown on the upper table); CTs that must be connected to the all models of General Protections (PG) declared in accordance with the standards DK5600 edition Va, 06-2006. TEN105R/N homopolar current transformers must power, with acceptable errors, the PG protection within the variable range accepted by the primary current. 100 A in resin, Class 5P20/0,5VA, secondary 1A 100 A in resin, Class 5P20/2VA, secondary 1A 100 A in resin, Class 5P20/2VA, secondary 1A protection N SO ICE EST R P QU RE 1100A 1100A 1100A TEN105RD • TEN105R TEN105N • • CURRENT TRANSFORMERS CEI-UNEL standards Dimensions according to CEI-UNEL 21009 std. Manufactured and tested acc. to IEC 60044-1 Standard burden: measure = cl 0,5 / 20VA; protection = cl 5P10 / 10VA Rated Insulation level up to 36 kV Frequency 50 or 60 Hz Rated primary current (Ipn) Single primary current from 5 to 2500 A Double primary current Up to 2 x 300 A change on prim. winding Up to 2 x 1250 A change on sec. winding Rated secondary current (Isn) 5 A Short-time current (Ith) up to 40 kA x 1s Rated dynamic current (Idyn) 2.5 x Ith Number of secondary 1 or 2 Safety factor ≤ 5 or ≤ 10 Indoor installation ON REQUEST Third secondary Rated secondary current 1A Sealable terminal cover Capacitive tap Other characteristics During the offer it is necessary to specify all technical details NOMINAL INSULATION Examples of order RAA111 300- 300A RAA121 500A RAA141 2k5 5A 5-5A 5-5-5A Maximum nominal current 600A - 1 secondary Maximum nominal current 600A - supplied with maximum 2 secondaries Maximum nominal current 1200A - supplied with maximum 2 secondaries Maximum nominal current 2500A - supplied with maximum 3 secondaries 12kV N SO ICE EST R P QU RE kg. 14 kg. 16 kg. 23 kg. 25 RAA111 • RAA121 RAA131 • • • NOMINAL INSULATION Examples of order RAB111 300- 300A RAB121 600A RAB161 2k5 5A 5-5A 5-5-5A Maximum nominal current 600A - 1 secondary Maximum nominal current 600A - supplied with maximum 2 secondaries Maximum nominal current 1000A - supplied with maximum 2 secondaries Maximum nominal current 2500A - supplied with maximum 3 secondaries 24kV N SO ICE EST R P QU RE kg. 16 kg. 18 kg. 25 kg. 28 RAB111 • RAB121 RAB131 5A 5-5A 5-5-5A Maximum nominal current2500A - supplied with maximum 3 secondaries RAB161 • • • NOMINAL INSULATION Examples of order RAC121 250- 250A RAC121 600A RAC121 2k5 RAA141 36kV ON ES ST C I PR QUE RE kg. 30 RAC121 • 75 08 listino GB media prezzi ITA:listino ITA 15/11/10 16:20 Pagina 76 BRICK TYPE CURRENT TRANSFORMERS Compact type suitable for METAL - CLAD switchboards Manufactured and tested acc. to IEC 60044-1 Standard burden: measure = cl 0,5 / 20VA; protection = cl 5P10 / 10VA Rated Insulation level up to 24 kV Frequency 50 or 60 Hz Rated primary current (Ipn) Single primary current from 5 to 1250 A Double primary current Up to 2 x 300 A change on prim. winding Up to 2 x 600 A change on sec. winding Rated secondary current (Isn) 5 A Short-time current (Ith) up to 40 kA x 1s Rated dynamic current (Idyn) 2.5 x Ith Number of secondary 1 or 2 Safety factor ≤ 5 or ≤ 10 Indoor installation ON REQUEST Third secondary Rated secondary current 1A Sealable terminal cover Capacitive tap Other characteristics During the offer it is necessary to specify all technical details NOMINAL INSULATION Examples of order RABM11 1k25 RABM22-A 1k25 RABM11-B 1k25 5A 5-5A 5-5-5A With metallic supports; In max 1250A; max 3 secondaries With metallic supports; In max 1250A; max 3 secondaries Secondary terminals A execution; In max 1250A; max 3 secondaries Secondary terminals A execution; In max 1250A; max 3 secondaries Secondary terminals B execution; In max 1250A; max 3 secondaries Secondary terminals B execution; In max 1250A; max 3 secondaries 24kV ON ES ST C I PR QUE RE kg. 18 kg. 24 kg. 18 kg. 25 kg. 18 kg. 25 RABM11 • RABM22 RABM11-A RABM22-A RABM11-B RABM22-B • • • • • DIN STANDARD CURRENT TRANSFORMERS Dimensions according to DIN 42 600 TEIL 8 std. Manufactured and tested acc. to IEC 60044-1 Standard burden: measure = cl 0,5 / 20VA; protection = cl 5P10 / 10VA Rated Insulation level up to 24 kV Frequency 50 or 60 Hz Rated primary current (Ipn) Single primary current from 5 to 2500 A Double primary current Up to 2 x 300 A change on prim. winding Up to 2 x 1250 A change on sec. winding Rated secondary current (Isn) 5 A Short-time current (Ith) up to 40 kA x 1s Rated dynamic current (Idyn) 2.5 x Ith Number of secondary 1 or 2 Security factor ≤ 5 or ≤ 10 Indoor installation Sec. terminal board acc. to DIN ON REQUEST Third secondary Rated secondary current 1A Capacitive tap Execution with wings Standard sec. terminal board Other characteristics During the offer it is necessary to specify all technical details NOMINAL INSULATION Examples of order RAAD11 2k5 RAAD11-N 2k5 RAAD11-AN 2k5 5A 5-5A 5-5-5A Standard execution; In max 2500A; max 3 secondaries Standard execution; In max 2500A; max 3 secondaries Standard execution; In max 2500A; max 3 secondaries Standard execution; In max 2500A; max 3 secondaries 12kV N SO ICE EST R P QU RE kg. 18 kg. 18 kg. 18 kg. 18 RAAD11 • RAAD11-A RAAD11-N • • • NOMINAL INSULATION Examples of order RABD11 2k5 RABD11-N 2k5 RABD11-AN 2k5 5A 5-5A 5-5-5A Standard execution; In max 2500A; max 3 secondaries Standard execution; In max 2500A; max 3 secondaries Standard execution; In max 2500A; max 3 secondaries Standard execution; In max 2500A; max 3 secondaries 76 RAAD11-AN 24kV ON ES ST C I PR QUE RE kg. 18 kg. 25 kg. 25 kg. 25 RABD11 • RABD11-A RABD11-N RABD11-AN • • • 08 listino GB media prezzi ITA:listino ITA 15/11/10 16:20 Pagina 77 VOLTAGE TRANSFORMERS CEI UNEL PHASE-PHASE STANDARDS 12kV - 24kV - 36kV Dimensions according to CEI-UNEL 21008 std. Manufactured and tested acc. to IEC 60044-2 Standard burden: measure = cl 0,5 / 50VA Rated Insulation level up to 36 kV Frequency 50 or 60 Hz Rated voltage factor 1,2 continuous Number of secondary 1 Rated secondary voltage 100 V Indoor installation During the offer it is necessary to specify all technical details Examples of order RVCA11 10/10 (10000/100V) RVCB11 20/10 (20000/100V) ON REQUEST Second secondary Double primary ratio Sealable terminal cover Rated secondary voltage 110 V Other characteristics ON ES ST C I PR QUE RE Nominal insulation 12kV - max 2 secondaries Nominal insulation 24kV - max 2 secondaries Nominal insulation 36kV - max 2 secondaries kg. 20 kg. 30 kg. 50 RVCA11 • RVCB11 • • PHASE-GROUND CEI-UNEL STANDARDS 12kV - 24kV - 36kV Dimensions according to CEI-UNEL 21007 std. Manufactured and tested acc. to IEC 60044-2 Rated Insulation level up to 36 kV Frequency 50 or 60 Hz Rated voltage factor 1,2 continuous and 1,9/8h Number of secondaries 2 Rated secondary voltage: Measuring or protective winding: 100: 3 V Residual voltage winding: 100:3 V Indoor installation During the offer it is necessary to specify all technical details Examples of order RVFA11 20R 1003 100R (20kV: RVFC11 20R 15R 103 10R (20kV: Nominal insulation 12kV : Nominal insulation 24kV : Nominal insulation 36kV : 3 / 100:3 / 100: 3) 3 - 15kV: 3 / 100:3 / 100: ON REQUEST Third secondary Double primary ratio Sealable terminal cover Rated secondary voltage: 110: Other characteristics 3 V - 110:3 V ON ES ST C I PR QUE RE 3) 3 - max 3 secondaries 3 - max 3 secondaries 3 - max 3 secondaries kg. 22 kg. 30 kg. 50 RVFA11 • RVFB11 • 12kV - 24kV Dimensions according to DIN42 600 TEIL 9 std. Manufactured and tested acc. to IEC 60044-2 Rated Insulation level up to 24 kV Frequency 50 or 60 Hz Rated voltage factor 1,2 continuous Number of secondary 1 Rated secondary voltage 100 V Indoor installation Sec. terminal board acc. to DIN During the offer it is necessary to specify all technical details Examples of order RVCAD1 10/10 (10000/100V) RVCBD1 20/10 (20000/100V) ON REQUEST Second secondary Double primary ratio Standard sec. terminal board Rated secondary voltage 110 V Other characteristics N SO ICE EST R P QU RE Nominal insulation12kV - max 2 secondaries Nominal insulation 24kV - max 2 secondaries kg. 22 kg. 30 RVCAD1 • 3 - max 2 secondaries 3 - max 2 secondaries RVCBD1 • PHASE-GROUND CEI-UNEL STANDARDS Nominal insulation 12kV : Nominal insulation 24kV : RVFC11 • PHASE-PHASE DIN STANDARDS Dimensions according to DIN42 600 TEIL 9 std. Manufactured and tested acc. to IEC 60044-2 Rated Insulation level up to 24 kV Frequency 50 or 60 Hz Rated voltage factor 1,2 continuous and 1,9/8h Number of secondary 2 Rated secondary voltage: Measuring or protective winding: 100: 3 V Residual voltage winding: 100:3 V Indoor installation Sec. terminal board acc. to DIN Examples of order RVFAD1 20R 1003 100R (20kV: 3 / 100:3 / 100: 3 RVFBD1 20R15R 103 10R (20kV: 3 - 15kV: 3 / 100:3 / 100: RVCC11 12kV - 24kV During the offer it is necessary to specify all technical details ON REQUEST Second secondary Double primary ratio Standard sec. terminal board Rated secondary voltage: 110: 3 V - 110:3 V Other characteristics N SO ICE EST R P QU RE 3 kg. 22 kg. 30 RVFAD1 • RVFBD1 • 77 08 listino GB media prezzi ITA:listino ITA 15/11/10 16:20 Pagina 78 PHASE-GROUND FUSE-HOLDER 12kV - 24kV Manufactured and tested acc. to IEC 60044-2 Rated Insulation level up to 36 kV Frequency 50 or 60 Hz Rated voltage factor 1,2 continuous and 1,9/8h Number of secondary 2 Rated secondary voltage: Measuring or protective winding: 100: 3 V Residual voltage winding: 100:3 V Indoor installation Examples of order RVFTS1 20R 1003 100R (20kV: RVFCS1 20R15R 103 10R (20kV: Nominal insulation 12kV : Nominal insulation 24kV : Nominal insulation 24kV : 3 / 100:3 / 100: 3 3 - 15kV: 3 / 100:3 / 100: During the offer it is necessary to specify all technical details ON REQUEST Third secondary Double primary ratio Sealable terminal cover Rated secondary voltage: 110: 3 V - 110:3 V Other characteristics ON ES ST C I PR QUE RE 3 3 - max 2 secondaries 3 - max 2 secondaries 3 - max 2 secondaries RVFTS1 • kg. 22 kg. 30 kg. 30 RVFBS1 RVFCS1 • • FUST • Fuse FUSB • FUSC • INSTRUMENTS FOR RAIL-WAY AND NAVAL USE VOLTMETERS MILLIVOLTMETERS DC MOVING COIL INSTRUMENTS DC MOVING COIL INSTRUMENTS Execution tropicalized, vibration resistant and antireflex glass Housing: metallic Vibration resistance up to 5g, frequency 5...80Hz applied on 3 axes Shock resistance max 30g applied on 3 axes Internal illumination by white LED, 24VDC, absorbed current 47mA; LED duration 70.000 hours Reading end scale value vertical from 0 to 40V black scale plate; divisions, number, words and symbols white colour red sector from 0 to 20V and from 30 to 40V orange pointer Execution tropicalized, vibration resistant and antireflex glass Housing: metallic Vibration resistance up to 5g, frequency 5...80Hz applied on 3 axes Shock resistance max 30g applied on 3 axes Internal illumination by white LED, 24VDC, absorbed current 47mA; LED duration 70.000 hours Reading end scale value vertical -300...0...+300A black scale plate; divisions, number, words and symbols white colour red sector from -300 to -200A and from 200 to 300A orange pointer ERCR96X48 V0-20Z5 351,00 Input 40VDC ERCR96X48 V0-20Z6 351,00 Input 150-0-150 mVDC MILLIAMMETERS DC MOVING COIL INSTRUMENTS Execution tropicalized, vibration resistant and antireflex glass Vibration resistance up to 5g, frequency 5...80Hz applied on 3 axes Internal illumination by white LED, 24VDC, absorbed current 47mA; LED duration 70.000 hours Reading end scale value black scale plate; divisions, number, words and symbols white colour, orange pointer Shock resistance max 30g applied on 3 axes Input 20mA DC End scale value 0-1,5kA Red sector fromt 1 to 1,5 kA End scale value 0-120C° Red sector from 65 to 120 °C End scale value 0-120°C Red sector from 0 to 45°C and from 100 to 120°C End scale value 0-2000 giri/min Red sector from 1800 to 2000 giri/min Housing: metallic ERCR96X48 V0-20Z1 351,00 ERCR96X48 V0-20Z2 ERCR96X48 V0-20Z3 ERCR96X48 V0-20Z4 351,00 351,00 351,00 VOLTMETERS DC MOVING COIL INSTRUMENTS Execution tropicalized, vibration resistant and antireflex glass Housing: self extinguishing thermoplastic according to UL94 V0 Vibration resistance up to 5g, frequency 5...80Hz applied on 3 axes Shock resistance max 30g applied on 3 axes Internal illumination by LED duration 70.000 hours Auxiliary supply 24VDC (range 8....32VDC +/- 5%) absorbed current 84mA max; Reading end scale value black scale plate; divisions, number, words and symbols white colour orange pointer ERCR65 40Z3 ERCR85 10Z1 ERCR85 10Z2 End scale End scale End scale End scale Diameter value value value value 0-40V, 240° 0-4kV, 240° 0-1200A, 240° -200....0....+200A and 0....400A, 240° Input 40VDC Input 10VDC Input 10VDC Input -80...0...+80mV and -10...0...+10mA ERCR85 10Z4 882,00 882,00 882,00 65 mm 85 mm 85 mm 882,00 85 mm MOVING COIL INSTRUMENTS WITH INTERNAL RECTIFIER Execution tropicalized, vibration resistant and antireflex glass Housing: self extinguishing thermoplastic according to UL94 V0 Vibration resistance up to 5g, frequency 5...80Hz applied on 3 axes Shock resistance max 30g applied on 3 axes Internal illumination by LED duration 70.000 hours Auxiliary supply 24VDC (range 8....32VDC +/- 5%) absorbed current 84mA max; Reading end scale value black scale plate; divisions, number, words and symbols white colour, orange pointer End scale value 0-500V, 240° Diameter 78 Input 25VAC ERCR65 25Z5 882,00 65 mm 08 listino GB media prezzi ITA:listino ITA 15/11/10 16:20 Pagina 79 SPECIAL IMPLEMENTATIONS For all the Instruments Linear scale plates hand drawn Non linear scale plates hand drawn Red or green mark Scale plates with unique trace and double or triple numbering Scale plates with double or triple trace and double or triple numbering Antiparallax scale plates Special words or symbols Coloured sectors Adjustable red pointer (48x48, 72x72, 96x96) 90° Central or offset zero Class 1 calibration D.C. calibration Non standard frequency calibration (400Hz at 5A) Calibration for other capacities according to curve Different capacities from the standard Double capacity Tropicalised execution IP54 protection degree IP55 protection degree Conformity certificate ACERT1 Test certificate, 8 values ACERT-CT8 Test certificate, 16 values ACERT-CT16 Test certificate, 20 valuesi ACERT-CT20 For scale plates For current transformers version 25,75 25,75 5,15 12,35 42,25 32,95 25,75 22,65 + clichée cost 18,55 38,10 17,50 8,25 12,35 17,50 10,30 22,65 10,30 9,25 10,30 9,80 14,95 17,50 19,60 72x72 instruments mounted on explosion proof case Put the prefix REX before the standard code Example: REX ERI 72500V D or REX ERB 7250/5A15 N SO ICE EST R P QU RE CONDITIONS OF SALE • The customer undertakes to accept The Terms And Conditions of srl when placing any order or instructions to supply products or services when unconfirmed by written or verbal agreement. Any alternative agreements presented by the customers, including any presented by an approved Stockist/Distributor or Agent of srl are only accepted when agreed in writting by srl. • All selling proces shown in our Pubblications are for use as a guide only and may be subject to change without prior notification. Prices charged at the time of delivery would be either against an official current quotation or prices current at the time of despatch which can be verified at the time of ordering. All Prices quoted are net and do not include any carriage costs. • All orders are packed to a high standard of safety. Delivery of orders whether by standard transport or by transport determined by the customers is at the customers risk. srl, it’s Distributor or Agents do not accept any liability for late, damaged, loss or theft incurred during delivery. Any claims for incorrect or faulty products must be made in writting within 8 days from date of despatch. Beyond such time no claim will be considered. • The guarantee, legal and contractual, is limited only to replacement of any procuct found to be defective through poor quality of material or workmanship and excludes any responsibility for direct or indirect damage, costs or delays incurred by the customer due to the defect. • The guarantee period for products is 12 months from manufacture or 18 months from the initial delivery date providing the products are handled and stored in a suitable condition. The guarantee does not include deterioration of the products through any missuse, including storage, incorrect terminal connection or installations by the end user. Where products are considered faulty these should be returned immediately to the supplier. Any on site investigation work carried out involving opening the product to reveal the internal components the guarantee is annulled unless otherwise performed following written permission from srl. • All products remain the property of srl until complete payment of the appropriate invoices has been received. Any late payments will be charged interest at the bank rate inforced at the actual time plus 3 points. • Return of goods is only accepted when authorised by srl in writting, any eventual delivery of returned goods must be to pour location in Milan, Free Off Charge. The returned goods will be credited at the actual buying prices less a 10% (ten percent) charge to cover administration and financial costs incurred by srl, unless otherwise agreed in writting. • In the case of any disputes, the local courts in Milan will act for srl to recover all debts incurred. The information and technical data presented in this catalogue may be subject to modifications, reserves the right to modify the actual data, without any notice at any time, to introduce new technologies and raw materials in order to maintain the best possible standards. The installation of the products must be carried out following the international standards of practice, by qualified people, and his agents will not accept any responsibility due the incorrect use or installation of any products, this includes, any responsibility for direct or indirect damage, costs or delays incurred by the customer due to the defect. Copyright© Revalco srl - 2010 - All right reserved. It is forbidden to reproduce totally or partially this catalogue, without any writting authorisation by Revalco srl. Revalco® is a trade mark. Printed by: Selgraph - Cocquio T. (VA) - Italy - Phone +39 0332 701422 79 cop catalistino AGENTI GB in A4:cop generale gb corretta 20/10/10 12:28 Pagina 2 Kazakhstan Gost Russia Via Giorgio Stephenson, 90 - 20157 MILANO ITALY Telephone ++39 02.39002153 - Fax ++39 02.39002207 Internet: www.revalco.it - E-mail: info@revalco.it Revalco is a patented brand name - Made in Italy Ediz. 2010.01.GB - Prices list validity: up to new edition that will cancel and replace the previous one ® ® 55DELIST-GB Underwriters Laboratories Inc. USA