Ponto Series A new concept for automation Ponto Series ® • • • • Programmable Controller Remote I/O for Field Buses Special models of I/O modules Web connection Programmable Controller • • • • High connectivity CPUs Direct connection by property bus of 12 Mbauds GBL Capacity: 4096 digital plus 512 analog User program memory: 512kb Programmable Controller • Ethernet and internet connection using WebPLC technology with Http, FTP and SMTP protocols • Fieldbus connection, for example PROFIBUS-Master Ponto CPUs ® Browser Memory Card CPU PRFIBUSDP Master Programming Interface Ethernet TCP/IP Serial Interface 2 Modbus Channel PC Architecture Ethernet I/O Modules Expansion Bus UCP Local Bus PROFIBUS Master Local Expansion Bus Remote Bus Field Bus Heads Remote Expansion PROFIBUS-DP Redundant Ethernet UCP PROFIBUS-DP Master 1 PROFIBUS-DP Master 2 PROFIBUS-DP Slaves I/O Modules Bus Capacities 10 modules max Intelligent module Segment 0 Segment 1 4 segments max Segment 2 30 modules maximum Segment 3 Internal GBL Bus • • • • • • 12Mbaud serial bus, I/O scan 0,45 ms for 480 points Patented by Altus Intelligent Modules with automatic identification and addressing Modules with hot-swap including PROFIBUS-DP heads Connection till 30 modules x 16 points = 480 points Full hardware implemented protocol with dedicated processor 12Mbaud Ponto Remote I/O ® • Altus • Remote connection to many brands of PLCs using field bus standard networks as PROFIBUS-DP, Devicenet, Ethernet or Modbus-RTU Connection to microcomputers to implement SOFTPLC Siemens AB PC GE Remote I/O to Altus CPUs Remote I/O to Remote I/O to AL-2000 Series Quark Series General Remote I/O S7 300 - Siemens CPUs Rockwell Control Logix Complete Redundant Solution Redundancy AL-2004 Redundant Programmable Controllers Redundant PROFIBUS-DP Master Redundant PROFIBUS-DP heads Channel Redundant PROFIBUS-DP optical connection Optical Redundant Network Module Features • • • • • • Hot-swap modules without disturbing field wiring Mechanical Key-switch with one code for each module type Fuse option for any kind of module Spring style terminals High connection density: 32 points in 10 cm Analog universal modules Field wiring Base B3 B4 RL3 RL4 RP3 RP4 RL3 RL4 RP3 RP4 M4 M4 B4 M3 M3 B3 RP1 RP2 RL2 RL2 RP2 RL1 RL1 Module RP1 B1 B2 M2 M2 B2 M1 M1 Label B1 RP3 RP4 RP4 RL4 RL4 RP3 B4 RL3 B3 RL3 B3 M4 B4 M3 M4 M3 RP1 RL2 RP2 RL2 RL1 RP2 RL1 B2 RP1 B1 B2 B1 M1 M2 M1 M2 Mechanic assembly Binding between the bases Module Field power supply Rail Base 24 Easy and Cheap to Mount A Common PLC Panel • • • • • • Controller Supply wiring Large quantities of Identification wires between controller and terminal Panel wiring blocks Power Supply Costly identification To many blocks per Supply wiring point Identification Complex power supply Terminal blocks wiring Identification Using of gutters for Field wiring internal wiring Bulky electrical project Easy and Cheap to Mount Identification • Power Supply • Controller • • Field wiring 100 90 80 70 60 50 40 30 20 10 0 • Ponto Tradicional Mão de Obra Materiais No I/O terminal blocks and associated panel wiring Cost Reduction of: workmanship, project and assembly. Panel size and cost reduction Time reduction in electric panel mounting Electric project simplified and standardized Easy and Cheap to Mount Controllers with 192 I/O Points 350 1200 24 950 24 220 • • • • 760 760 20% Smaller area 47% Smaller depth 50% Smaller volume Cost reduction of more than 30% in the electrical panel Ponto and Internet ® • WebPLC: Integrated internet protocols for remote supervision and diagnostics – Http ( browsers ) – FTP ( file transfers ) – SMTP ( e-mail ) Http Ethernet TCP/IP FTP SMTP Ponto and Internet ® • • • • • CPUs pages Browser access • Use in Gateway applications to other equipment Complete remote diagnostics E-mail to events and alarms Use in Pager and Mobile applications “C” language and JAVA programming for special applications Ponto CPUs Models ® PO3042 PO3042 PO3142 PO3142 PO3242 PO3242 PO3342 PO3342 Ethernet network network Ethernet No No No No Yes Yes Yes Yes Web protocols protocols Web No No No No No No Yes Yes Serial port port RS232 RS232 1 1 Serial Yes Yes Yes Yes Yes Yes Yes Yes Serial port port RS232 RS232 2 2 Serial No No Yes Yes No No No No Serial port port RS485 RS485 Serial Yes Yes Yes Yes Yes Yes Yes Yes Real Time Time Clock Clock Real Yes Yes Yes Yes Yes Yes Yes Yes Flash memory memory Flash 128K 128K 256K 256K 256K 256K 256K 256K Ram memory memory Ram 256K 256K 256K 256K 256K 256K 256K 256K I/O modules modules I/O 16 16 30 30 30 30 30 30 Modbus Master/Slave Master/Slave Modbus No No Yes Yes Yes Yes Yes Yes PROFIBUS PROFIBUS No No No No Yes Yes Yes Yes Floating point point operation operation Floating Yes Yes Yes Yes Yes Yes Yes Yes Ethernet Interface - PO7091 • • • • • • • Web server with HTML and XML format Supervisory system with Flash, Java, JavaScript and VBScript Ethernet and internet Connection using ALNET I protocol Interlock between PLC´s as master operation mode Remote programming and monitoring Transport protocols: TCP / IP Controlled access by passwords in HTML pages Webgate Plus - PO9901 • • • • • • • • To any kind of Altus CPU Web server with HTML e XML format Supervisory system with Flash, Java, JavaScript e VBScript Ethernet and internet connection for ALNET I Interlock between PLC´s as master operation mode Remote programming and monitoring Transport protocols: TCP / IP Controlled access by passwords in HTML page Profibus-DP Master - PO4053 • • • • • All standard Profibus-DP Master functions Capacity of 3584 input bytes and 3584 output bytes Allows to implement redundant network architectures using PO5063V4 Head Full PROFIBUS-DP diagnostic RS-232 channel to I/O configuration, supervision and local diagnostic Profibus-DP Slave Head • All standard Profibus-DP Slave functions • Connection up to 20 I/O modules • Allows the use of a local Operator Panel to diagnostics • Supply diagnostic to PROFIBUS-DP Master PO7079 - High Speed Counter • • • • • Two counter inputs that can work with up/down mode or quadrature One configurable digital input with instantaneous reading, nulling or habilitation One configurable digital output to indicate upper limit, lower limit or no limit Configurable counting range – up to 32 bits binary with signal Measurement mode for frequency, period and angular frequency Pro-Ponto Configuration SW • • • • • • Easy to Configurate PROFIBUS-DP Ponto Series systems Verification of the validity of configuration Complementary tool of the software of programming Mastertool 3.0 Tag allocation to I/O points Module parameterization Generation of labels and documentation Ponto Series Products ® PO 1xcc 1000 Input Modules PO 2xcc Output Modules PO 3xcc UCPs PO 4xcc Field bus interfaces PO 5xcc Field bus heads PO 6xxx 1000 Bases PO 7xcc Special modules PO 8xcc Power supplys and acessories PO 9xxx Software for UCPs Input modules Code Module PO 1000 16 ED 24 Vdc opto PO 1001 16 ED 110 Vac opto PO 1002 16 ED 220Vac opto PO 1003 16 ED 48 Vdc opto PO 1004 16 ED 125 Vdc opto PO 1010 32 ED 24 Vdc opto PO 1112 8 EA isolated universal PO 1113 8 EA I/V isolared Bases for input modules Code Module PO 6000 1000 I/O Digital Spring Base PO 6001 I/O Analog Spring Base PO 6050 I/O Digital Screw Base PO 6051 I/O Analog Screw Base PO 6100 I/O Digital Spring Base with Fuse PO 6101 I/O Analog Spring Base with Fuse PO 6150 Base E/S Digital c/Fusíveis I/O Digital ScrewParafuso Base with Fuse PO 6151 I/O Analog Screw Base with Fuse Base E/S Analógica Parafuso c/Fusíveis Bases for special modules Code Module PO 6302 1000 UCP PO3x42 Base PO 6400 MODBUS and PROFIBUS field bus interface base PO 6402 DEVICENET field bus interface base PO 6404 AS-I field bus interface base PO 6500 MODBUS and PROFIBUS field bus head base PO 6501 ETHERNET field bus head base PO 6502 Base p/cabeça debus redehead de campo DEVICENET field base DEVICENET PO 6800 Powerp/fonte supply base Base Output modules Code Module PO 2020 1000 16 SD 24 Vdc / 2 A transistor opto PO 2021 16 SD 110/220 Vac / 2 A triac opto PO 2022 16 SD Relé 2 A NA contato seco PO 2023 16 SD 48 Vdc transistor opto PO 2024 16 SD 125 Vdc transistor opto PO 2028 24 SD 24 Vdc/0,5 A transistor PO 2132 4 SA universal isolado Field bus interface Code Module PO 4050 1000 MODBUS field bus interface PO 4053 PROFIBUS-DP field bus interface PO 4054 DEVICENET field bus interface PO 4056 Rede AS-I interface Field bus heads Code Module PO 5060 1000 MODBUS field bus head PO 5061 Ethernet field bus head PO 5063 PROFIBUS-DP field bus head PO 5064 DEVICENET field bus head