Power Module with EcoSystemR LQSE-2ECO-D EcoSystemR Controller 369611a 1 08.07.12 ECO 1 ECO 2 COM QS MUX The Power Module with EcoSystemR unit is a DIN-rail mounted Eco Link controller for EcoSystemR ballasts, drivers and devices. It provides Eco Link power and control for two independent Eco Links with up to 64 ballasts or drivers each. MUX Power Module with EcoSystemR Hi Temp Power Module with EcoSystem® Features •Provides EcoSystemR Link power for two links of EcoSystemR ballasts or drivers (up to 250 mA 4 per link). •Power failure memory retains control unit programming in the event of a power loss. •Includes QS link for connection to a HomeWorksR QS system. •Power Module with EcoSystemR unit can be used in a HomeWorksR QS system to control and manage light in an entire home or building. L N Test LQSE-2ECO-D Power www.lutron.com +44.(0)20.7702.0657 Z096 230 V~ 50/60 Hz 80 mA Patent: 7,391,297 8 mm System Example Eco Link 1 Eco Link 2 Power Module with EcoSystem® unit 230 V~ Control Power HomeWorksR QS Wallstation Power Module Ballast Ballast Ballast Ballast QS Contact HomeWorksR QS Closure Processor Interface Up to 64 ballasts on each link GRAFIK EyeR QS QS Link Up to 100 total QS devices SivoiaR QS Shade / Drapery QS Power Supply ® Job Name: Job Number: S p e c i f i c at i o n S u b m i t ta l Model Numbers: Page 1 Up Power Module with EcoSystemR LQSE-2ECO-D EcoSystemR Controller 369611a 2 08.07.12 Specifications Power •230 V~ 50/60 Hz 80 mA •Lightning strike protection meets ANSI/IEEE standard 62.31-1980. Can withstand voltage surges of up to 6 000 V~ and current surges of up to 3 000 A. •Stand by power: 7 W •BTUs / hour when fully loaded: 24 •Eco Link Output: 16 V- 250 mA maximum per link. •Digitally define areas and zones. •Automatic replacement of a single failed ballast or driver. •Simple method of replacing multiple failed ballasts or drivers. •EcoSystemR Digital Link can be wired as Mains voltage or IEC PELV/NECR Class 2 for maximum wiring flexibility. •EcoSystem® Link wires are polarity insensitive and topology-free. EcoSystemR Digital Link Limits Standards •IEC 60669-2-1 •Lutron Quality Systems registered to ISO 9001.2008. •CE •C-Tick S Environment •Ambient Temperature Operating Range: 0 ºC to 40 ºC. •Relative humidity: less than 90% non-condensing. •Calibration point maximum: 75 ºC •For indoor use only. •Up to 64 EcoSystemR-compatible fluorescent ballasts and/or LED drivers per EcoSystemR digital link. •EcoSystemR-compatible fluorescent ballasts and LED drivers on the EcoSystemR digital link do not count as QS devices. QS Link Limits •A QS link in a HomeWorks® QS system can have up to 512 zones (outputs) and 100 devices. A ballast or driver counts as 1 zone unless specifically grouped into zones from the HomeWorks® QS software. Terminals •Each Power Module with EcoSystemR unit counts as •Mains wiring: 1,0 mm2 to 4,0 mm2 (18 AWG to 12 AWG) one device toward the 100 device limit. •Eco Link Wiring: 1,0 mm2 to 4,0 mm2 (18 AWG to 12 AWG) •A maximum of 8 fully loaded EcoSystemR digital links •QS Link Wiring: 1,0 mm2 (18 AWG) may be connected to a single QS link. Mounting HomeWorksR QS Wallstations •Intended to mount within an IP20 (minimum) rated •HomeWorksR QS wallstations can be configured to consumer panel or breaker panel with integrated DIN control Power Module with EcoSystemR units with the rail and dead cover HomeWorksR QS programming utility. •Width = 9 DIN modules (161,7 mm). • LED indicator displays the status of programmed lights. Programming and Compatibility Requirements Troubleshooting and Maintenance •The LQSE-2ECO-D can only be used with the Features HomeWorksR QS system. •Maintains redundant memory of ballast programming •Setup and programming of the Power Module with for ease of single or multiple ballast replacement. EcoSystemR unit is done through the HomeWorksR QS •To verify EcoSystem® lights connected to ECO link 1 programming software. and link 2: •HomeWorksR QS software version 3,0 or higher required. – Enter Test Mode: Press and hold Test button on EcoSystemR the Power Module with EcoSystemR until the Test •Control up to 64 EcoSystemR-compatible devices (ballast LED starts flashing. or LED drivers) per EcoSystemR Digital Link (up to – Test: Each press of either the ECO 1 or ECO 2 128 devices per Power Module with EcoSystemR unit). button will cycle the lights between high-end, low-end, flash, and off for that link. NEC is a registered trademark of the National Fire Protection Association, Quincy, Massachusetts – Exit Test Mode: Press and hold Test button until Test LED stops flashing. 2 ® S p e c i f i c at i o n S u b m i t ta l Page Job Name: Job Number: Model Numbers: Power Module with EcoSystemR LQSE-2ECO-D EcoSystemR Controller 369611a 3 08.07.12 Overview of Wiring Terminals and Mechanical Dimensions IEC PELV/ NECR Class 2 QS Link Eco Link 1* Eco Link 2* 500-13431 Rev. B ECO 1 ECO 2 COM MUX QS MUX Z096 N1771 89,7 mm Hi Temp Power Module with EcoSystem® L Test LQSE-2ECO-D Power www.lutron.com +44.(0)20.7702.0657 Z096 230 V~ 50/60 Hz 80 mA N Patent: 7,391,297 Up 8 mm 161,7 mm Mains Wiring * Wire according to local codes. 60,6 mm NEC is a registered trademark of the National Fire Protection Association, Quincy, Massachusetts ® Job Name: Job Number: S p e c i f i c at i o n S u b m i t ta l Model Numbers: Page 3 Power Module with EcoSystemR LQSE-2ECO-D EcoSystemR Controller 369611a 4 08.07.12 Wiring: Mains Voltage Hi Temp Power M COM MUX MUX Module Unit LQSE-2 QS Wiring from Distribution to PowerTest Hi Temp Power Module with EcoSystem® LQSE-2ECO-D www.lutron.com +44.(0)20.7702.0657 Hi Temp Power Module with EcoSystem 230 V~ 50/60 Hz 80 mA Patent: 7,391,297 8 mm L Up Test LQSE-2ECO-D Power www.lutron.com +44.(0)20.7702.0657 • Use normal (non-essential) power only to power the 230 V~ 50/60 QS Hz Emergency 80 mA Lighting Applications COM Test Power MUX N Z096 MUX L wires from a8 mm • Run line, neutral, and earth/ground L N 230 V~ 50/60 Hz feed to the Power Module with ® EcoSystemR unit. ECO 1 ECO 2 COM MUX QS MUX 230 V~ • Turn off all circuit breakers or isolators feeding the www.lutron. Power Power Module unit at the distribution panel. Power Module with EcoSystemR unit. N 8 mm • EcoSystemR ballasts and drivers are programmed to enter emergency mode when the Eco link looses power. Hi Temp Power Module with EcoSystem • When normal power drops out, the Power Module with L Test EcoSystemR unit will not power the Eco Links. When LQSE-2ECO-D this occurs, ballasts powered from emergency feeds go QS Power www.lutron.com +44.(0)20.7702.0657 N 8 mm N COM MUX MUX to their emergency mode,80 full light output by default. 230 V~ 50/60 Hz mA Mains Wiring and IEC PELV/NECR Class 2 Separation • The Power Module with EcoSystemR unit is designed to separate mains wiring from IEC PELV/ ® NECR Class 2 circuits. Hi Temp Power Module with EcoSystem L Test Power L N • Follow appropriate local and national codes to avoid LQSE-2ECO-D violating required separation guidelines. 230 V~ 50/60 Hz 80 mA Distribution Panel www.lutron.com +44.(0)20.7702.0657 – Earth/Ground8 mm N – Neutral L – Mains/Live NEC is a registered trademark of the National Fire Protection Association, Quincy, Massachusetts ® Job Name: Job Number: S p e c i f i c at i o n S u b m i t ta l Model Numbers: Page 4 Power Module with EcoSystemR LQSE-2ECO-D EcoSystemR Controller 369611a 5 08.07.12 Wiring: Eco Link ECO 1 ECO 2 COM MUX QS MUX Power Module with EcoSystemR unit will supply power for two independent Eco Links, which support a maximum of 64 ballasts per link. Hi Temp Power Module with EcoSystem® L Test LQSE-2ECO-D Power www.lutron.com +44.(0)20.7702.0657 N Z096 230 V~ 50/60 Hz 80 mA Patent: 7,391,297 Up 8 mm Eco Link 1 Eco Link 2 Eco 1 Eco 2 Eco 1 Eco 2 Eco Wiring •EcoSystemR Digital Link can be wired as Mains voltage or IEC PELV/NECR Class 2 for maximum wiring flexibility. • The Link is polarity insensitive and can be wired in any topology. • Consult all national and local electrical codes for separation requirements. Wire CrossSectional Area 4,0 mm2 (12 AWG) 2,5 mm2 (14 AWG) 1,5 mm2 (16 AWG) 1,0 mm2 (18 AWG) Maximum EcoSystemRcompliant Link Wire Length 829 m 518 m 311 m 207 m EcoSystemR Digital Link ECO 1 ECO 2 EcoSystemR H-Series Ballast EcoSystemR LED Z096 Up to 64 EcoSystemR ballasts or LED drivers Patent: 7,391,297 Up NEC is a registered trademark of the National Fire Protection Association, Quincy, Massachusetts ® Job Name: Job Number: S p e c i f i c at i o n S u b m i t ta l Model Numbers: Page 5 Power Module with EcoSystemR LQSE-2ECO-D EcoSystemR Controller 369611a 6 08.07.12 Wiring: QS Link Hi Temp Power Module with EcoSystem® L Test LQSE-2ECO-D Power www.lutron.com +44.(0)20.7702.0657 N • Link communicates using IEC PELV/NECR Class 2 wiring. ECO 1 ECO 2 COM MUX QS MUX IEC PELV/NECR Class 2 QS Link Wiring Z096 230 V~ 50/60 Hz 80 mA Patent: 7,391,297 Up 8 mm • Follow all applicable national and local codes for proper circuit separation and protection. • Wiring may be daisy chained or t-tapped. • Total length of QS link must not exceed 600 m. • Do NOT connect terminal 2. COM MUX QS MUX • Wire Gauge - Power (terminals 1 and 2): 1 pair 1,0 mm( (18 AWG) - Data (terminals 3 and 4): 1 pair 0,5 mm( to 1,0 mm( (20 AWG to 18 AWG) twisted and shielded - Can use LutronR cable GRX-CBL-346S-500 (1) COM (2) No Connection (3) MUX (4) MUX Module with EcoSystem® 2ECO-D ECO 1 ECO 2 Z096 50/60 Hz 80 mA .com +44.(0)20.7702.0657 Patent: 7,391,297 Up NEC is a registered trademark of the National Fire Protection Association, Quincy, Massachusetts ® Job Name: Job Number: S p e c i f i c at i o n S u b m i t ta l Model Numbers: Page 6