Power Module with EcoSystem Spec Submittal 369611a

advertisement
Power Module with EcoSystemR
LQSE-2ECO-D
EcoSystemR Controller
369611a 1 08.07.12
ECO 1 ECO 2
COM
QS
MUX
The Power Module with EcoSystemR unit is a
DIN-rail mounted Eco Link controller for EcoSystemR
ballasts, drivers and devices. It provides Eco Link
power and control for two independent Eco Links
with up to 64 ballasts or drivers each.
MUX
Power Module with EcoSystemR
Hi Temp Power Module with EcoSystem®
Features
•Provides EcoSystemR Link power for two links of
EcoSystemR ballasts or drivers (up to 250 mA
4 per link).
•Power failure memory retains control unit
programming in the event of a power loss.
•Includes QS link for connection to a
HomeWorksR QS system.
•Power Module with EcoSystemR unit can be used in
a HomeWorksR QS system to control and manage
light in an entire home or building.
L
N
Test
LQSE-2ECO-D
Power
www.lutron.com +44.(0)20.7702.0657
Z096
230 V~ 50/60 Hz 80 mA
Patent: 7,391,297
8 mm
System Example
Eco Link 1
Eco Link 2
Power
Module with
EcoSystem® unit
230 V~
Control Power
HomeWorksR QS
Wallstation
Power
Module
Ballast
Ballast
Ballast
Ballast
QS
Contact
HomeWorksR QS Closure
Processor
Interface
Up to 64
ballasts on
each link
GRAFIK
EyeR QS
QS Link
Up to 100
total QS
devices
SivoiaR QS
Shade / Drapery
QS
Power
Supply
®
Job Name:
Job Number:
S p e c i f i c at i o n S u b m i t ta l
Model Numbers:
Page
1
Up
Power Module with EcoSystemR
LQSE-2ECO-D
EcoSystemR Controller
369611a 2 08.07.12
Specifications
Power
•230 V~ 50/60 Hz 80 mA
•Lightning strike protection meets ANSI/IEEE standard
62.31-1980. Can withstand voltage surges of up to
6 000 V~ and current surges of up to 3 000 A.
•Stand by power: 7 W
•BTUs / hour when fully loaded: 24
•Eco Link Output: 16 V- 250 mA maximum per link.
•Digitally define areas and zones.
•Automatic replacement of a single failed ballast or driver.
•Simple method of replacing multiple failed ballasts
or drivers.
•EcoSystemR Digital Link can be wired as Mains voltage
or IEC PELV/NECR Class 2 for maximum wiring flexibility.
•EcoSystem® Link wires are polarity insensitive and
topology-free.
EcoSystemR Digital Link Limits
Standards
•IEC 60669-2-1
•Lutron Quality Systems registered to ISO 9001.2008.
•CE
•C-Tick S
Environment
•Ambient Temperature Operating Range: 0 ºC to 40 ºC.
•Relative humidity: less than 90% non-condensing.
•Calibration point maximum: 75 ºC
•For indoor use only.
•Up to 64 EcoSystemR-compatible fluorescent ballasts
and/or LED drivers per EcoSystemR digital link.
•EcoSystemR-compatible fluorescent ballasts and LED
drivers on the EcoSystemR digital link do not count as
QS devices.
QS Link Limits
•A QS link in a HomeWorks® QS system can have up
to 512 zones (outputs) and 100 devices. A ballast or
driver counts as 1 zone unless specifically grouped
into zones from the HomeWorks® QS software.
Terminals
•Each Power Module with EcoSystemR unit counts as
•Mains wiring: 1,0 mm2 to 4,0 mm2 (18 AWG to 12 AWG)
one device toward the 100 device limit.
•Eco Link Wiring: 1,0 mm2 to 4,0 mm2 (18 AWG to 12 AWG)
•A maximum of 8 fully loaded EcoSystemR digital links
•QS Link Wiring: 1,0 mm2 (18 AWG)
may be connected to a single QS link.
Mounting
HomeWorksR QS Wallstations
•Intended to mount within an IP20 (minimum) rated
•HomeWorksR QS wallstations can be configured to
consumer panel or breaker panel with integrated DIN
control Power Module with EcoSystemR units with the
rail and dead cover
HomeWorksR QS programming utility.
•Width = 9 DIN modules (161,7 mm).
• LED indicator displays the status of programmed lights.
Programming and Compatibility Requirements
Troubleshooting and Maintenance
•The LQSE-2ECO-D can only be used with the
Features
HomeWorksR QS system.
•Maintains redundant memory of ballast programming
•Setup and programming of the Power Module with
for ease of single or multiple ballast replacement.
EcoSystemR unit is done through the HomeWorksR QS
•To
verify EcoSystem® lights connected to ECO link 1
programming software.
and link 2:
•HomeWorksR QS software version 3,0 or higher required.
– Enter Test Mode: Press and hold Test button on
EcoSystemR
the Power Module with EcoSystemR until the Test
•Control up to 64 EcoSystemR-compatible devices (ballast
LED starts flashing.
or LED drivers) per EcoSystemR Digital Link (up to
– Test: Each press of either the ECO 1 or ECO 2
128 devices per Power Module with EcoSystemR unit).
button will cycle the lights between high-end,
low-end, flash, and off for that link.
NEC is a registered trademark of the National Fire Protection Association, Quincy,
Massachusetts
– Exit Test Mode: Press and hold Test button
until Test LED stops flashing.
2
® S p e c i f i c at i o n S u b m i t ta l
Page
Job Name:
Job Number:
Model Numbers:
Power Module with EcoSystemR
LQSE-2ECO-D
EcoSystemR Controller
369611a 3 08.07.12
Overview of Wiring Terminals and Mechanical Dimensions
IEC PELV/
NECR Class 2
QS
Link
Eco
Link 1*
Eco
Link 2*
500-13431 Rev. B
ECO 1 ECO 2
COM
MUX
QS
MUX
Z096
N1771
89,7 mm
Hi Temp Power Module with EcoSystem®
L
Test
LQSE-2ECO-D
Power
www.lutron.com +44.(0)20.7702.0657
Z096
230 V~ 50/60 Hz 80 mA
N
Patent: 7,391,297
Up
8 mm
161,7 mm
Mains
Wiring
* Wire according to local codes.
60,6 mm
NEC is a registered trademark of the National Fire Protection Association, Quincy, Massachusetts
®
Job Name:
Job Number:
S p e c i f i c at i o n S u b m i t ta l
Model Numbers:
Page
3
Power Module with EcoSystemR
LQSE-2ECO-D
EcoSystemR Controller
369611a 4 08.07.12
Wiring: Mains Voltage
Hi Temp Power M
COM
MUX
MUX
Module Unit
LQSE-2
QS Wiring from Distribution to PowerTest
Hi Temp Power Module with EcoSystem®
LQSE-2ECO-D
www.lutron.com +44.(0)20.7702.0657
Hi Temp Power Module with EcoSystem
230 V~ 50/60 Hz 80 mA
Patent: 7,391,297
8 mm
L
Up
Test
LQSE-2ECO-D
Power
www.lutron.com +44.(0)20.7702.0657
• Use normal (non-essential) power only to power the
230 V~ 50/60
QS
Hz Emergency
80 mA Lighting Applications
COM
Test
Power
MUX
N
Z096
MUX
L
wires from a8 mm
• Run line, neutral, and earth/ground
L N
230 V~ 50/60 Hz feed to the Power Module with
®
EcoSystemR unit.
ECO 1 ECO 2
COM
MUX
QS
MUX
230 V~
• Turn off all circuit breakers or isolators feeding the
www.lutron.
Power
Power Module unit at the distribution panel.
Power Module with EcoSystemR unit.
N
8 mm
• EcoSystemR ballasts and drivers are programmed to
enter emergency mode when the Eco link looses
power.
Hi Temp Power Module with EcoSystem
• When normal power drops out, the Power Module with
L
Test
EcoSystemR unit will not power the Eco Links. When
LQSE-2ECO-D
this occurs,
ballasts powered from emergency feeds go
QS
Power
www.lutron.com +44.(0)20.7702.0657
N
8 mm
N
COM
MUX
MUX
to their
emergency
mode,80
full light
output by default.
230 V~
50/60
Hz
mA
Mains Wiring and IEC PELV/NECR Class 2
Separation
• The Power Module with EcoSystemR unit is designed
to separate mains wiring from IEC PELV/
®
NECR Class 2 circuits.
Hi Temp
Power Module with EcoSystem
L
Test
Power
L
N
• Follow appropriate local and national codes to avoid
LQSE-2ECO-D
violating required separation guidelines.
230 V~ 50/60 Hz 80 mA
Distribution
Panel
www.lutron.com +44.(0)20.7702.0657
– Earth/Ground8 mm
N – Neutral
L – Mains/Live
NEC is a registered trademark of the National Fire Protection Association, Quincy, Massachusetts
®
Job Name:
Job Number:
S p e c i f i c at i o n S u b m i t ta l
Model Numbers:
Page
4
Power Module with EcoSystemR
LQSE-2ECO-D
EcoSystemR Controller
369611a 5 08.07.12
Wiring: Eco Link
ECO 1 ECO 2
COM
MUX
QS
MUX
Power Module with EcoSystemR unit will supply
power for two independent Eco Links, which
support a maximum of 64 ballasts per link.
Hi Temp Power Module with EcoSystem®
L
Test
LQSE-2ECO-D
Power
www.lutron.com +44.(0)20.7702.0657
N
Z096
230 V~ 50/60 Hz 80 mA
Patent: 7,391,297
Up
8 mm
Eco Link 1
Eco Link 2
Eco 1
Eco 2
Eco 1
Eco 2
Eco Wiring
•EcoSystemR Digital Link can be wired as Mains
voltage or IEC PELV/NECR Class 2 for maximum
wiring flexibility.
• The Link is polarity insensitive and can be wired in
any topology.
• Consult all national and local electrical codes for
separation requirements.
Wire CrossSectional Area
4,0 mm2 (12 AWG)
2,5 mm2 (14 AWG)
1,5 mm2 (16 AWG)
1,0 mm2 (18 AWG)
Maximum EcoSystemRcompliant Link Wire Length
829 m
518 m
311 m
207 m
EcoSystemR Digital Link
ECO 1 ECO 2
EcoSystemR H-Series Ballast
EcoSystemR LED
Z096
Up to 64 EcoSystemR ballasts
or LED drivers
Patent: 7,391,297
Up
NEC is a registered trademark of the National Fire Protection Association, Quincy, Massachusetts
®
Job Name:
Job Number:
S p e c i f i c at i o n S u b m i t ta l
Model Numbers:
Page
5
Power Module with EcoSystemR
LQSE-2ECO-D
EcoSystemR Controller
369611a 6 08.07.12
Wiring: QS Link
Hi Temp Power Module with EcoSystem®
L
Test
LQSE-2ECO-D
Power
www.lutron.com +44.(0)20.7702.0657
N
• Link communicates using IEC PELV/NECR
Class 2 wiring.
ECO 1 ECO 2
COM
MUX
QS
MUX
IEC PELV/NECR Class 2 QS Link Wiring
Z096
230 V~ 50/60 Hz 80 mA
Patent: 7,391,297
Up
8 mm
• Follow all applicable national and local codes for
proper circuit separation and protection.
• Wiring may be daisy chained or t-tapped.
• Total length of QS link must not exceed 600 m.
• Do NOT connect terminal 2.
COM
MUX
QS
MUX
• Wire Gauge
- Power (terminals 1 and 2): 1 pair 1,0 mm( (18 AWG)
- Data (terminals 3 and 4): 1 pair 0,5 mm( to 1,0 mm(
(20 AWG to 18 AWG) twisted and shielded
- Can use LutronR cable GRX-CBL-346S-500
(1) COM
(2)
No Connection
(3) MUX
(4) MUX
Module with EcoSystem®
2ECO-D
ECO 1 ECO 2
Z096
50/60 Hz 80 mA
.com +44.(0)20.7702.0657
Patent: 7,391,297
Up
NEC is a registered trademark of the National Fire Protection Association, Quincy, Massachusetts
®
Job Name:
Job Number:
S p e c i f i c at i o n S u b m i t ta l
Model Numbers:
Page
6
Download