® Multi-Application Peripherals and Accessories ULC Listed* Non-Coded Manual Stations 2099 Series Single and Double Action Operation Features • Single action models FIRE ALARM • Breakglass type double action models • Institutional option: – Key operated only PULL DOWN • Pull lever protrudes when alarmed • Tamper resistant reset key lock: – keyed same as fire alarm cabinet • Pre-signal and annunciator contact options Single Action Station • Surface or semi-flush mounting • Flush mounting option • Two stage alarm • English, French, or Bilingual Operation Single Action Stations require a firm downward pull to activate the alarm switch. Completing the action breaks an internal plastic break-rod (visible below the pull lever). The pull lever latches into the alarm position and remains extended out of the cover to provide a visible indication of which station was alarmed. Double Action Stations (Breakglass) require the operator to strike the front mounted hammer to break the glass and expose the recessed pull lever. The pull lever then operates as a single action station. Single action stations can be fitted with an institutional cover kit. Institutional Stations are designed to activate by key operation only. This allows access for manual alarms to be limited to authorized personnel. Operation requires key insertion and opening of the station cover. Pre-signal option activates when the lever is pulled. General alarm initiation requires a key to activate a keyswitch located behind the pull lever. Station Reset requires use of a key to reset the pull station lever and deactivate the alarm switch. If the break-rod is used, it must be replaced. FIRE ALARM BREAK PULL GLASS DOWN Double Action Station (Breakglass) FIRE ALARM KEY OPERATED ONLY Single Action Station with Institutional Cover Testing requires physical activation of the pull lever (except for institutional stations). © 2000 Simplex International Time Equipment Co. Ltd. S12099-0007-1 9/00 Applications According to the National Building Code, a manual pull station shall be installed in every floor area near every required exit. CAN/ULC-S524-M91 states that stations “shall be mounted not less than 1200 mm nor more than 1400 mm above the floor level...”. In addition, the National Fire Protection Assocation (NFPA), Bulletin number 72 (reference section 5-9), gives specific minimum requirements on this subject. When manual station coverage appears limited in any way, additional units should be installed. Stations should be mounted with the bottom of the station not less than 1.07 m (3.5 ft.) or more than 1.52 m (5 ft.) from the floor. Usually stations are mounted at the 1.37 m (4.5 ft.) level. (In order to make buildings and facilities accessible to, and usable by the physically handicapped, some specifications may require that the station be installed not more than 1.07 m (3.5 ft.) from the floor.) Stations should be located in the normal path of exit, and distributed in the protected area so that they are unobstructed and readily accessible. Stations should be provided on each floor to obtain a travel distance not more than 61 m (200 ft.) to the nearest station from any point in the building. One station should be provided for each floor where the maximum floor area is 2 2 930 m (10,000 ft. ) or more. Construction. Covers and pull levers are constructed of chip resistant and dirt resistant, high impact Lexan polycarbonate. Covers are red with white lettering and pull levers are white with red lettering. The 2099-9819 (Black) and 2099-9820 (Beige) are optional adapter kits designed to flush mount any one of the 2099 series stations. Non-addressable Manual Station Specification Chart Single Action Models Actuator 2099-9754C N/O Actuator Annun. GA Key Single Gang Box Depth mm (inches) 38 (1.5) 2099-9288C N/O N/O 51 (2.0) 2099-9752C N/O:C/L N/O 51 (2.0) 2099-9101C N/O N/O 2099-9107C N/O N/O N/O 76 (3.0) 2099-9110C N/O:C/L N/O N/O 51 (2.0) 2099-9102C N/O N/C 2099-9109C N/O N/C N/O 76 (3.0) 2099-9111C N/O:C/L N/C N/O 51 (2.0) Double Action Models - Breakglass Actuator Actuator Annun. GA Key Single Gang Box Depth mm (inches) 2099-9103C N/O 2099-9336C N/O N/O 51 (2.0) 2099-9772C N/O:C/L N/O 51 (2.0) 2099-9104C N/O N/O 2099-9108C N/O N/O N/O 2099-9118C N/O:C/L N/O N/O 2099-9105C N/O N/C 2099-9117C N/O N/C N/O 76 (3.0) 2099-9119C N/O:C/L N/C N/O 51 (2.0) 51 (2.0) 51 (2.0) 38 (1.5) 51 (2.0) 76 (3.0) 51 (2.0) 51 (2.0) N/O = Normally Open Contact — N/C = Normally Closed Contact — C/L = Current Limited when activated MODELS SHOWN ARE ENGLISH LANGUAGE. ADD ‘F’ FOR FRENCH – ‘B’ FOR BILINGUAL e.g. 2099-9754C, 2099-9754CF, 2099-9754CB Accessories Model Description 2099-9803 Replacement breakglass (standard, English) 2099-9804 Replacement break-rod 2099-9819 Flush adapter kit, black (refer to page 4) 2099-9820 Flush adapter kit, beige (refer to page 4) 2099-9822 Replacement retaining clip for breakglass 2099-9828 Institutional cover kit 2975-9178 Red, surface mount box, sheet metal, 5 3/16” H x 4” W x 2 3/16” D (127 mm x 102 mm x 56 mm) 2975-9022 Red, cast aluminum surface mount box, 5” H x 3 7/8” W x 2 3/16” D (127 mm x 98 mm x 56 mm) 12975-0001 Red, surface mount box, sheet metal, 5 3/16” H x 4” W x 2 11/16” D (127 mm x 102 mm x 68 mm) S12099-0007-1 9/00 Page 2 Mounting Information Refer to installation instructions (PER-21-502CAN) for additional information. SURFACE MOUNTING 4” (102 mm) Knockouts for 3/4 inch conduit located top and bottom 12975-0001 or 2975-9178 Box FIRE ALARM 5” 3/16 (132 mm) Station cover hinges open for installation access PULL DOWN 5” (127 mm) 12975-0001 – 2 11/16” (68 mm) 2975-9178 – 2 3/16” (56 mm) 12975-0001 or 2975-9178 Box 1” (25.4 mm) 3 3/4” (95 mm) Side View, Surface Mounting SEMI-FLUSH MOUNTING, 4” BOX (refer to selection chart for requirements) 4” (102 mm) square box, 2 1/8” (54 mm) minimum depth RACO #231 or equal (supplied separately) FIRE Electrical box Station side view ALARM PULL DOWN Single gang cover plate Single gang cover plate, 3/4” (19 mm) extension, RACO #773 or equal (supplied separately) Wall Surface Side View, Semi-Flush Mounting S12099-0007-1 9/00 Page 3 Mounting Information (continued) FLUSH MOUNTING REFERENCE INFORMATION Front View Flush mount adapter kit 2099-9819, Black 2099-9820, Beige Side View Box must be recessed into wall 1” to 1 1/8” (25.4 mm to 29 mm) FIRE ALARM 8” (203 mm) 6” (152 mm) PULL DOWN 4 3/4” (121 mm) Hole cutout must be a minimum of 6” H x 5” W (152 mm by 127 mm) Wall Surface 4 11/16” (119 mm) square box, 2 1/8” (54 mm) minimum depth (by others) 6 3/4” (171 mm) Simplex, the Simplex logo, MAPNET, and IDNet are either trademarks or registered trademarks of Simplex Time Recorder Co. in the U.S. and/or other countries. NFPA 72 and National Fire Alarm Code are registered trademarks of the National fire Protection Association (NFPA). Lexan is a registered trademark of General Electric Co. ® S12099-0007-1 9/00 2400 Skymark Avenue, Mississauga, Ontario L4W 5K5 Offices and Representatives Throughout the World. Visit us on the world wide web at www.simplexnet.com All specifications and other information shown were current as of printing and are subject to change without notice. Printed in Canada.